HomeMy WebLinkAboutPermit M07-285 - INTERNAPINTERNAP 3355 S 120 PL M07 -Z85 Parcel No.: 1023049069 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 3355 S 120 PL TUKW INTERNAP 3355 S 120 PL , TUKWILA WA SABEY CORPORATION 12201 TUKVVILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: JEFFREY PENCEK Address: 228 E 45 ST, 7 FLOOR , NEW YORK NY Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA Contractor License No: HERMACLOOSBJ DESCRIPTION OF WORK: ROOFTOP MOUTED AIR HANDLING UNITS, EXHAUST FANS FOR COOLING, AND VENTILATING OF NEW DATA CENTER. Value of Mechanical: 200,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 1 6 0 5 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 203 536 -2152 Phone: 206 - 575 -9700 Expiration Date: 08/25/2008 M07 -285 01/11/2008 07/09/2008 Fees Collected: $7,440.63 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 10 Diffuser 10 Thermostat 6 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 2 Other Mechanical Equipment 0 M07 -285 Printed: 01 -11 -2008 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The grant s of this permit construction • r e peYformanc Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us i<10- Permit Number: M07 -285 Issue Date: 01/11/2008 Permit Expires On: 07/09/2008 Date: 14 l resume to give authority to violate or cancel the provisions of any other state or local laws regulatinc ork. I = . " orized to sign and obtain this mechanical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 -285 Printed: 01 -11 -2008 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Tenant: INTERNAP 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -285 Status: ISSUED Applied Date: 12/20/2007 Issue Date: 01/11/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M07 -285 Printed: 01 -11 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 20: Local U.L. central station supervision is required. (City Ordinance #2051) 21: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 23: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinker heads. (IFC 901.4) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 25: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 27: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 28: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -285 Printed: 01 -11 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: ordinances governing or local laws regulating M07 -285 Printed: 01 -11 -2008 Site Address: Tenant Name: Property Owners Name: Sabey Corporation Mailing Address: 12201 Tukwila International Blvd. Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: CITY OF TUKAteA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Internap Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 3355 South 120th Place Jeffrey Pencek 2211 F 45th StrPpt, 7th Fl r. jpencek @ha- ny.com Cortland Morgan, Architect, AIA 711 N. Fielder Road Jeff Smith Jeff @cmaia.net The Purdy Consultants 14850 Montfort Drive, Suite 250 Lawrence Purdy E - Mail Address: ilpurdy@jlenterprises.com NApplicationsWorms- Applications On Line3-2006 - Permit Application. doc Revised 9 -2006 bh King Co Assessor's Tax No.: 1 Or2%1p (0"1 Suite Number: New Tenant: Seattle City Day Telephone: 203 - 536 - 2152 New York city Fax Number: Arlington City Day Telephone: Fax Number: NY 10017 212 -tg1 -0200 ZIP cit Day Telephone: Fax Number: Expiration Date: State TX 76012 State Zip 817 -636 -5696 817 - 636 -5699 Dallas City Day Telephone: Fax Number: 972- 3R6 -6R37 TX State 972 - 386 -6836 Zip Floor: ❑ Yes 123..No WA State Zip Zip 75254 Page 1 of6 BUILDING PERX%iIT INFO Valuation of Project (contractor's bid price): $ 500,000 Existing Building Valuation: $ Scope of Work (please provide detailed information): Provide a co- location data center fitting up existing shell space. Fit -up includes cooling. Will there be new rack storage? ❑ Yes [�.. No If yes, a separate permit and plan submittal will be required. 183,292 SF 9,900 SF 1 —FR FI PLANNING DIVISION: N/A Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 1 Sprinklers J Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes M No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM N/A ❑ On -site SepticSystem — For on -site septic system, provide 2 copies of 'a current septic design approved by King County Health Department. Q: Appli cations \Forms -Appli cations On LineO -2006 - Permit Application. doc Revised: 9 -2006 bh Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Air Handling Unit >10,000 CFM 6 Fire Damper 1 0 Furnace >100K BTU Evaporator Cooler Diffuser 10 3 - HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 5 Thermostat 6 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 2 50+ HP /I,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Command .iVIECIi,NIC.LTERMI'' INFORMATION - 206 -3i - 3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 1,200,000 Scope of Work (please provide detailed information): Rooftop mounted air handling units / exhaust fans for cooling / ventilating of new data center. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... ❑ Fuel Type: Electric 10 Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q: Applications\Forms- Applications On Line \3-2006 - Permit Application.doc Revised, 9.2006 bh State Zip Page 4 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: Mailing Address: Date Application Accepted: 0 ' ED AGENT: t? 4- — 9(4tD $i (-► Day Telephone: %2' nti — rise E 45 ST, 143)* 60 Date Application Expires: aoIwlflq 4 7-0 I 0 Q On Line \3-2006 - Permit Application doc Revised: 9 -2006 bh City Date: 12 4'67 to i ISM State Zip Staff Initials: Page 6 of 6 Doc: RECSETS -06 RECEIPT NO: R07 -02824 Initials: JEM User ID: 1165 Payee: RUBICON INTEGRATION, LLC SET ID: S000000924 SET NAME: Trap set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us D07 -475 2,605.19 M07 -285 1,199.55 TOTAL: 3,804.74 TRANSACTION LIST: Type Method Description Payment Check 1162 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES SET RECEIPT TOTAL: Payment Date: 12/20/2007 Total Payment: 3,804.74 Amount 3,804.74 3,804.74 Account Code Current Pmts 000/345.830 3,804.74 TOTAL: 3,804.74 6303 12/20 9710 TOTAL 3804.74 RECEIPT NO: R08 -00902 Initials: JEM User ID: 1165 Payee: RUBICON Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http../Iwww.ci.tukwila.wa.us SET ID: 032511 SET NAME: INTERNAP SET TRANSACTIONS: Set Member Amount D07 -475 58.00 M07 -285 58.00 TOTAL: 116.00 TRANSACTION LIST: Type Method Description Amount Payment Cash 116.00 TOTAL: 116.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila SET RECEIPT Payment Date: 03/25/2008 Total Payment: 116.00 Account Code Current Pmts 000/322.100 58.00 000/345.830 58.00 TOTAL: 116.00 Receipt No.: R08 -00099 Initials: BLH User ID: ADMIN Payee: HERMANSON COMPANY LLP TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description doc: Receiot -06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL - NONRES 000/322.100 PLAN CHECK - NONRES 000/345.830 RECEIPT Parcel No.: 1023049069 Permit Number: M07 -285 Address: 3355 3 120 PL TUKW Status: APPROVED Suite No: Applied Date: 12/20/2007 Applicant: INTERNAP Issue Date: Amount Payment Check 56169 6,241.08 Account Code Current Pmts Payment Amount: $6,241.08 Payment Date: 01/11/2008 12:34 PM Balance: $0.00 5,958.50 282.58 Total: $6,241.08 7135 01/11 9710 TOTAL 6241.08 Printed: 01 -11 -2008 Pro Type of Inspection: Address: 3 , 53 S /2d , / Date Called: Special Instructions: Date Wa ed: �.rJL .L �_Q d p.m. Reque ter: Phone No: -.3Z— y70 W&P k INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: �J � ► , , 1 t„J ( n � 1 �S � p�� , 104 44.5 tti% v . Tr\,f c . -eA, } � tit 4 v l�S Y er r f - per, -a ( 7 DI L Inspe� �� I r a $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: Type of Inspectio : 1 iJ 6-44C iles � i� - Ps i, ' p - /' ie rt �X (N i e- 73 lie r. -4 `7 ) /t la s ! -e £J e A-- /'/_P -r ,,,a, ,.e, . Requester: l,Jjt /)-{1) ,t i A -Al 4v >/ i r:754-3/- & AI' 0 5 - ,.P ei-4 6 r 4 -' 6(6.i I t7 * ,2 A v)i1 - Projec-4. -- -;1/ ° r�v�i ' r? Type of Inspectio : 1 iJ A ress: 355' ..S / 2a P/ Date Called: _ SpecialInstruc \ 3 SJC� vV bU / r j (1r'1 , , Date apted v 4 / /- p.m Requester: Phone No: 73 - V70_25 fr INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Inspect r ILLI ?of rnv7-26S Corrections required prior to approval. Date OA ,/ El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: ptkit'Aira i*, c,ouf-ef VA 9_ et rifigi k ) _;J v [- Address: TG 3355 S oall lib - L s Date Call d: S t 3 p Pt 0ucJ L I E -elr Ar'e Date Wanted: or a.m. . ,,--pr.i — ti. rc-.se r (0 .) r ) ,..5...fi"--At , Phone No: 3zdo — 571 ' cia-t, t b Z G 1 (.a nA c e:NI A -t 4o ki - f4.41 Z- 4 3 etc, - 40X40 go /-oaF 4- 4(?? 7" )G Pt, 0 a-F— i Project: =/ t ti A T e of Inspection: i� k(7"l j O •C Address: TG 3355 S oall lib - PL— Date Call d: Special Instructions: Date Wanted: or a.m. . ,,--pr.i — ti. Requester: Phone No: 3zdo — 571 INSPECTION RECORD Retain a copy with permit , INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 El Approved per applicable codes. El Corrections required prior to approval. Inspector: m Date: r d ,1 a $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Veroq AA P/ -4o Type of05,4oh 46 )(4o • .. /26 PL.— 4 MC - 1 A 50 NTE ,..k. Ai) ‘, AS pe t4 5i-Neerr e r6 0 \i/ u f t--h5 1 ()Mk., OAF (gAc cu'r&si - LA--tt i- ( re Date Wanted e-,? ' 4 c., / t. .,p.m. Requeste Phona 7 57 ... 7V3 4 A AI`r )kir S Lk-41 5 Pk c`'' .e e 6-0-it 3u ef Fly KJ AC (kh--.1U0 6)C.A.-170 ‘/I AA( Surttk 6 /2 i. ) fc_5 , I Project: 'vet /17/9/) Type of05,4oh • .. /26 PL.— 4 Date Called: Special Ins ructions: Date Wanted e-,? ' 4 c., / t. .,p.m. Requeste Phona 7 57 ... 7V3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 El Approved per applicable codes. 7-2P5 PERMIT NO. (206)431 El Corrections required prior to approval. 'Inspect r: IDate: 19 og $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: COMMENTS: ' Type of Inspection: Address: : ' - '' Suite #: _ -' Contact Person: ..: . Phone No.: - Monitor: Pre-Fire: Permits: z Occupancy Type: „,- , ' _ • .: ,...... '7 ,...) C .',.. .- ,' . , ';' e ... ; . '- ... 4 _ . , t i .' - - •-• t , ,.......t. _ „, Project: -- • 1 :. - - , ',. , ' Type of Inspection: Address: : ' - '' Suite #: _ -' Contact Person: Special Instructions: . Phone No.: - Needs Shift Inspection: 0 „,' Sprinklers: Fire Alarm: ,- / Hood & Duct: Monitor: Pre-Fire: Permits: z Occupancy Type: „,- , ' 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 INSPECTION NUMBER Fl Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT • "" Inspector I • t . Date: L Hrs.: 2 — $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS Corrections required prior to approval. T.F.D. Form F.P. 113 DEPARTMENTS: Buil ing (vision Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 PERMIT COORD GOP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -285 PROJECT NAME: INTERNAP SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # DATE: 12 -20 -07 Response to Incomplete Letter # Revision # After Permit Issued n tile- Alin/ Pip Fire Prevention I J Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: Incomplete Planning Division C ❑ Permit Coordinator n DUE DATE: 12-27 -07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 01-24-08 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -285 DATE: 03 -18 -08 PROJECT NAME: INTERNAP SITE ADDRESS: 3355 S 120 PL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued DEPARTMENTS: Boilwng"Divis n Public Works ❑ Complete Please Route Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: TUES/THURS RQUTING: Elf 1 # 1 4. 3•2.Q o� Fire Prevention L Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required DUE DATE: 03 -20-08 ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 04 -17 -08 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator Not Applicable x Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 3 — fl - OS 0 i r‘d Summary of Revision: he(A) exh„ 0 l 0 ra � S - ee. M 3 Received by: J e A14 VITA) TA) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: Ilyr\- -cr q SITE ADDRESS: 33,5c S f 1-0 ?1 REVISION LOG PERMIT NO: 11 1A O7- 2.S S ORIGINAL ISSUE DATE: \ o9 (please print) (please print) (please print) (please print) (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: iittp: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 31I 7l DR Plan Check/Permit Number: Mo) - 2A3� ❑ Response to Incomplete Letter if ❑ Response to Correction Letter # (a Revision # ,_ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name:,, n,cF' .er- en Project Address: 3 ' 3 5 - S 1 2x9 `• L p i R t o Contact Person: T e- Phone Number: 212 Summary of Revision: EN.IM.p - 4.-,+• Steven M. Mullet, Mayor Steve Lancaster, Director ist -vii v ry CITY OF TUKWI A MAR 17 2008 ,7 : ran arr ne7NTE4 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Er Entered in Permits Plus on 3 ( 1 - 0 0 1gmlication :\foams - applications on line\revision submittal License Information License HERMACL005BJ Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 1221 2ND AVE N Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC *217NT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HERMANSON, RICHARD L PARTNER/MEMBER 01/01/1980 Bond Amount ALMON, KEVIN PARTNER/MEMBER 01/01/1980 MACDONALD, JAMES PARTNER/MEMBER 01/01/1980 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 01/11/2008 A5E3iRE V I AT IONS ABv. ABOVE AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AL ACOUSTICAL LINING ATC AUTOMATIC TEMPERATURE CONTROL BD BLOW -DOWN LINE BDD BACKDRAFT DAMPER B.G. BOTTOM GRILLE BHP BRAKE HORSEPOWER BSR BASIN SWEEPER RETURN 555 BASIN SWEEPER SUPPLY BTU BRITISH THERMAL UNIT BTLJH BTU PER HOUR CC COOLING COIL CD_ CEILING DIFFUSER CFM CUBIC FEET PER MINUTE C.G. CEILING GRILLE ClHWP CHILLED WATER PUMP CHWR CHILLED WATER RETURN CHW5 CHILLED WATER SUPPLY CLG. CEILING CON T. . CONTINUATION C.R CEILING REGISTER Cr? ",C COMPUTER ROOM AIR CONDITIONER CT COOLING TOWER cW DOMESTIC COLD WATER CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY D DRAIN DB DRY BULB DEG. DEGREES DN DOWN DWG DRAWING EA EACH EAT_ ENTERING AIR TEMPERATURE EDS ENTERING DRY BULB EF EXHAUST FAN EH ELECTRIC HEATER EQL EQUILIZATION LINE ES EQUAL SPLIT ESP EXTERNAL STATIC PRESSURE EWB ENTERING WET BULB TEMPERATURE E.W.T. ENTERING WATER TEMPERATURE EXIST. EXISTING °F DEGREES FAHRENHEIT FC FLEXIBLE CONNECTION FCv FLOW CONTROL VALVE FD FUSIBLE LINK FIRE DAMPER W /DUCT ACCESS DOOR FL. FLOOR FLA. FULL LOAD AMPS FPM PEET PER MINUTE FSD COMBINATION FIRE SMOKE DAMPER H.P. NORSE POWER HR HOUR IN INCHE5 KW KILOWATT LAT. LEAVING AIR TEMPERATURE LDB LEAVING DRY BULB TEMPERATURE L.W.T. LEAVING WATER TEMPERATURE MAX_ MAXIMUM MBH THOUSAND BTU PER HOUR MCA MINIMUM CURRENT AMPICITY MCC MOTOR CONTROL .CENTER MER MECHANICAL EQUIPMENT ROOM MIN. MINIMUM MUW MAKE -UP WATER My MOTORIZED VALVE NCWT NON - CHEMICAL WATER TREATMENT OF OVERFLOW LINE PCHWP PRIMARY CHILLED WATER PUMP PCWP PRIMARY CONDENDER WATER PUMP PCWR PRIMARY CONDENDER WATER RETURN PCWS PRIMARY GON5ENDER WATER SUPPLY PHX PLATE AND FRAME HEAT EXCHANGER N/A NOT APPLICABLE NG NORMALLY CLOSED N_LC NOT IN THIS CONTRACT NK NECK No NORMALLY OPEN N.T.S. NOT TO SCALE 041 OUTSIDE AIR INTAKE OBD OPPOSED BLADE DAMPER PD PRESSURE DROP PD. PUMP DISCHARGE PROP. PROPELLER P.R.Y. PRESSURE REDUCING VALVE PSI(G) POUNDS PER SQUARE INCH (GAUGE) R RISE RA RETURN AIR REFRIG. REFRIGERATION RH RELATIVE HUMIDITY RPM REVOLUTIOI•te PER MINUTE SA SUPPLY AIR SCWP SECONDARY CONDENSER WATER PUMP SCWR SECONDARY CONDENSER WATER RETURN SCWS SECONDARY CONDENDER WATER SUPPLY 5D SMOKE DAMPER SPEF SMOKE PURGE EXHAUST FAN 51P STATIC PRESSURE SWR SECONDARY SUPPLY RETURN SWS SECONDARY WATER SUPPLY TF6 TOWER FILTRATION SYSTEM T. TRANSFER DUCT TRG. TRANSFER GRILLE TX TOILET EXHAUST UN UNIT HEATER VD VOLUME DAMPER voL. voLUME W/ WITH WB WET BULB WMS WIRE MESH SCREEN WPR WORKING PRESSURE XT EXPANSION TANK (300) 300 CUBIC FEET OF AIR PER MINUTE DUCTLUO K LEGEND R7 v L 7 CC 11 D I8x12 18X12 l8 "? 011110 r ALD / LED 1 FD vD FD I FD vAV'A (500) z (0) L //f/ /i SUPPLY DUCT UP SUPPLY DUCT DOWN RETURN OR EXHAUST DUCT UP RETURN OR EXHAUST DUCT DOWN SLOPING RISE IN DUCTWORK SLOPING DROP IN DUCTWORK ACCESS DOOR IN DUCT DUCT SIZE (CLEAR INSIDE DIMENSION) 'R5T FIGURE INDICATES PLAN SIZE ROUND DUCT DIAMETER SIZE ACOUSTIC LINING IN DUCT (SIZE NOTED INDICATES INSIDE DIMENSIONS) FLEXIBLE CONNECTION VOLUME DAMPER AUTOMATIC LOUVER DAMPER FUSIBLE LINK FIRE DAMPER 1 1 1 /DUCT ACCESS DOOR EL SOW WITH TURNING VANES MOTORIZED DAMPER DUCT SPLIT BRANCH TAKEOFF WITH VOLUME DAMPER RADIUS ELBOW HEATING COIL FUSIBLE LINK FIRE DAMPER VAV BOX vAv "DESIGNATION " (CFM) CEILING DIFF=USER (4 -WAY) RETURN REGISTER OR GRILLE FLEXIBLE DUCT LOUVER DOOR (SQUARE FEET) UNDERCUT DOOR NEW WORK EXISTING WORK EXISTING WORK TO BE REMOVED POINT OF DISCONNECTION FROM EXISTING WORK POINT OF NEW CONNECTION TO EXISTING WORK THERMOSTAT DUCT MOUNTED SMOKE DETECTOR BACKDRAFT DAMPER FSD W/ ACCESS DOOR -HW5 -- --� - )S F-1WS- ► HOT WATER SUPPLY -HW — � 3— 1-10T WATER RETURN - S (WS) - - ,-5 (WS) -4- SECONDARY (WATER SUPPLY) -e (WR) - SECONDARY (WATER RETURN) -CWS r CWS- - ►-g CONDENSER WATER SUPPLY -CWR ■ s-CWR- - -w3- CONDENSER WATER RETURN -CHWS ir-CHW5- -11.- 3- CHILLED WATER SUPPLY - GHWR_- - 5- CHWR -- — CHILLED WATER RETURN - GS GLYCOL SUPPLY -Gr -4 GLYCOL RETURN REFRIGERANT LIQUID PIPING REFRIGERANT SUCTION PIPING - R -SV—� - f - REFRIGERANT - SAF=ETY VALVE RELIEF LINE HOT GAS PIPING --FOV_- f FQV-- --- —*3— FUEL OIL vENT - 13-FO5- - FUEL OIL SUPPLY -FOR ErFoR— — FUEL OIL RETURN FOG FUEL OIL -GAUGE LINE -FOP FFOF - - -3 FUEL OIL FILL - c w - b-Cw- - - DOMESTIC COLD WATER MAKE -UP ARROW INDICATES DIRECTION OF FLOW P� PITCH PIPE DOWN IN DIRECTION OF ARROW DRAIN LINE v VENT LINE PIPE ANCHOR PIPE GUIDE FLEXIBLE BALL JOINT EXPANSION COMPENSATOR -E— - - REDUCER ECCENTRIC REDUCER (E.R) —�I UNION D:I 7 _s -> CAPPED PIPE WITH GATE SHUT -OFF VALVE "Y" TYPE STRAINER BASKET TYPE STRAINER DUPLEX STRAINER ELBOW TURNED UP ELBOW TURNED DOWN r, BOTTOM PIPE CONNECTION TOP PIPE CONNECTION C C SLOPED CHANGE IN PIPE ELEVATION I FLEXIBLE CONNECTION DIRT POCKET PIPING LEGEND (3' -0" X 6 ' -0 ") (3' -0" X 6' -i2) ") EXPANSION LOOP (SIZE) STRAINER W/ GATE VALVE 4 HOSE CONNECTION r DEAD END- SCREWED CAP FLANGED END PRESSURE REDUCING VALVE WITH "FEELER" PIPE FLOAT OPERATED vALvE t REFRIGERANT EXPANSION VALVE SIGHT GLASS T I4OSE BIBS VALVE IN VERTICAL 4M MANUAL AIR VENT 1 A AUTOMATIC AIR VENT -1 THERMOMETER PIPE SENSOR WELL. (THERMOMETER) PRESSURE GAUGE AND COCK FLOW BALANCING/METERING STATION THERMOSTAT TRAP HEAVY DUTY FLOAT TRAP 0 0 HEATING ELEMENT HEATING ELEMENT WITH AUTOMATIC CONTROL VALVE GATE VALVE — s— GLOBE VALVE N CHECK VALVE AUTOMATIC THREE WAY CONTROL VALVE RELIEF YAL VE - [[1>r<3- PRESSURE REDUCING VALVE (PRV) SOLENOID VALVE LUBRICATED PLUG VALVE LOCKSHIELD GLOBE VALVE _ 3 — BUTTERFLY vALvE BUTTERFLY AUTOMATIC CONTROL VALVE 6 BALL VALVE RISER DESIGNATION seE RISER SERVICE RISER NUMBER GENERAL NOTES 1. LOCATE DIFFUSERS AND GRILLES AS SHOWN ON ARCHITECTURAL REFLECTED CEILING PLANS. ROUTE PIPING AS SHOWN ON PLANS. VALVES, FITTINGS AND TRIM SHALL 5E AS SHOWN ON FLOW DIAGRAMS, DETAILS 4 PLANS REFERENCE STRUCTURAL DRAWINGS AND DETAILS FOR EXACT LOCATIONS OF EQUIPMENT. 2. SEE SPECIFICATIONS FOR ACCESS DOOR REQUIREMENTS. SHOW ACCESS DOOR SIZES AND LOCATIONS ON DUCTWORK SHOP DRAWINGS. 3. SCOPE OF WORK IS IDENTIFIED BY DRAWINGS AND SPECIFICATIONS. ALL SYMBOLS AND ABBREVIATIONS LISTED ON SYMBOLS AND ABBREVIATIONS SHEET ARE NOT NECESSARILY USED ON THE DRAWINGS FOR THIS PROJECT. 4, DUCT SIZES SHOWN ON DRAWINGS ARE NET SIZES INSIDE LINING. 5- PRIOR TO FABRICATION OF PIPE OR DUCT SECTIONS THAT WILL CONNECT TO EQUIPMENT, PIPE OR DUCT DIMENSIONS SHALL BE VERIFIED AND MODIFIED AS REQUIRED TO FIT ACTUAL EQUIPMENT INSTALLED ON THE JOB. ALL OPENINGS AND PAD DIMENSIONS FOR EQUIPMENT SHALL BE VERIFIED AGAINST ACTUAL EQUIPMENT TO BE INSTALLED ON THE JOB. 6. PIPE PENETRATIONS THROUGH FIRE RATED WALLS 514ALL HAVE FIRE RATED SLEEVES AND SHALL BE CAULKED WITH RTV SILICONE FOAM_ FOAM USED IN FIRE RATED WALLS SHALL BE UL. LISTED. -T. ALL DIFFUSERS ARE 4 -WAY THROW UNLESS INDICATED OTHERWISE. 8. PROVIDE VENTS AT ALL HIGH POINTS AND DRAINS AT ALL LOW POINTS OF EACH PIPING SYSTEM. DRAIN SHALL CONSIST OP 3/4" BALL VALVE WITH HOSE ADAPTER g. AIR CONDITIONING CONDENSATE DRAIN PIPING SHALL BE TYPE "L" COPPER TUBING WITH DWV PATTERN FITTINGS. PROVIDE 3" DEEP TRAPS AT UNIT CONNECTIONS. INSULATE ALL DRAINS WITH 1/2" THICK ASJ FIBERGLASS INSULATION. 10. ALL POWER WIRING SHALL BE 5Y THE ELECTRICAL SUBCONTRACTOR. PIPE MOUNTED DEVICES SHALL BE MOUNTED BY HYAC SUBCONTRACTOR DUCT MOUNTED DEVICES SHALL BE MOUNTED BY THE SHEETMETAL SUBCONTRACTOR UNLESS OTHERWISE NOTED. 11. SHEET METAL SUBCONTRACTOR SHALL PROVIDE ACCESS DOORS IN DUCTS AT ALL AUTOMATIC CONTROL DAMPERS, FIRE DAMPERS, SMOKE DAMPERS, AND ELECTRIC DUCT HEATERS. 12_ MECHANICAL CONTRACTOR SHALL PROVIDE DRIP PANS UNDER DUCTWORK AND FAN COIL UNITS INSTALL BELOW THE ROOF. DRIP PANS 51 4ALL BE EQUIPPED WITH LEAK DETECTORS AND PLUMBED DRAIN. THE SUBCONTRACTOR RESPONSIBLE FOR RECEIVING AND SETTING IN PLACE DESIGNATED EQUIPMENT SHALL PROVIDE ANY AND ALL MATERIAL AND LABOR REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS AND DRAWINGS. 13. FINAL LOCATIONS OF ROOF PENETRATIONS FOR EXHAUST FANS, RELIEF VENTS AND METAL SMOKESTACKS/VENTS SHALL BE IN ACCORDANCE WITI -I INTENT OF HYAC DRAWINGS. SHEETMETAL SUBCONTRACTOR SHALL SUBMIT DRAWINGS OF FINAL ROOF OPENING LOCATIONS AND SIZES INCLUDING SUPPLEMENTAL STEEL FOR APPROVAL OF I- IIGHLAND PRIOR TO THE COMMENCEMENT OF WORK AND AS NECESSARY TO COORDINATE WITH SCHEDULED ROOFING WORK. SUPPLEMENTAL STEEL FOR THE ABOVE REFERENCED I rEMS NOT SHOWN OR DETAILED ON STRUCTURAL STEEL DRAWINGS SHALL BE FURNISHED AND INSTALLED BY THE SHEETMETAL SUBCONTRACTOR 14, MECHANICAL PIPING SHALL BE RUN AT LOCATION, ELEVATIONS AND IN CONFIGURATION AS SHOWN ON DRAWINGS. ALL STEEL, CONCRETE, ETC., REQUIRED FOR SUPPORT OF MECHANICAL PIPINGS SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR MECHANICAL CONTRACTOR SHALL SUBMIT DRAWINGS AND DETAILS OF MECHANICAL PIPING SUPPORT STEEL TO ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO THE COMMENCEMENT OF WORK 15. I-IVAC SYSTEMS AS SHOWN ON DRAWINGS AND SPECIFIED IN SPECIFICATIONS SHALL BE SEISMICALLY BRACED AS PER THE REQUIREMENTS OF THE LATEST EDITION OF APPLICABLE CODE. Irv. VERIFY ALL DIMENSIONS AND CLEARANCES IN THE FIELD TO ESTABLISH MANUFACTURER'S REQUIRED SERVICE CLEARANCES. 1 CONTRACTOR 514ALL PERFORM ALL WORK IN A NEAT, ORDERLY AND rtr: ESSIONAL MANNER WITHOUT DISRUPTION TO THE WORK OF OTHER CONTRACTORS. IS. MECHANICAL CONTRACTOR 51-ALL FOLLOW OWNER'S SAFETY RULES ANI3 SHALL BROOM CLEAN DAILY_ ALL DEBRIS SHALL BE REMOVED FROM THE BUILDING AND GROUNDS. ie. MECHANICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND APPROVALS AND PAY ALL FEES REQUIRED BY GOVERNING BODIES REQUIRED FOR MECH. WORK BEFORE COMMENCING WORK 20. NO COMBUSTIBLE MATERIALS WILL BE PERMITTED IN UNDERFLOOR OR CEILING PLENUMS AND INTERSTITIAL SPACES. 21. ALL ELECTRICAL WORK 51-IALL BE IN ACCORDANCE WITH TI-IE LATEST REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. 22. MECHANICAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR MECHANICAL WORK 23, WHERE EQUIPMENT IS INDICATED BY MANUFACTURER AND /OR MODEL NUMBER, THE ENGINEER 15 INDICATING SAME ONLY AS THE BASIS OF DESIGN. TI-4E ENGINEER IS NOT INDICATING A SPECIFIC REQUIREMENT FOR THE 50 DESIGNATED. EQUIPMENT WHICH PRODUCES THE SAME PERFORMANCE AND /OR CHARACTERISTICS AND 15 MANUFACTURED BY AN ACCEPTABLE MANUFACTURER AS LISTED IN THE PROJECT SPECIFICATIONS ARE CONSIDERED ACCEPTABLE SUBSTITUTIONS. ANY REENGINEERING OR REDESIGN OF EQUIPMENT LAYOUT OR ASSOCIATED MECHANICAL, ELECTRICAL, STRUCTURAL OR ARCHITECTURAL WORK RESULTING FROM EQUIPMENT SUBSTITUTIONS SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR ANY COSTS ASSOCIATED WITH REENGINEERING OR REDESIGNING SHALL BE BORNE 5Y THE MECHANICAL CONTRACTOR 24. PROVIDE PERMANENT IDENTIFICATION OF EACH HEATING, COOLING, VENTILATING OR REFRIGERATION SYSTEM INSTALLED, IDENTIFYING AREA SERVED, PER SCHEDULES AND PLANS. 25_ MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE- DEVELOPED RATING OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH THE TEST FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, UNIFORM BUILDING CODE No 42-1. 26_ ALL STEEL DUCTS (NOT LESS THAN 26 GAUGE) PENETRATING FIRE RESISTIVE WALLS WITH RATING OF MORE THAN I HOUR SHALL HAVE A SMOKE/FIRE DAMPER INSTALLED AT SAID PENETRATION. 21. FIRE DAMPERS SHALL NAVE A LABEL OR OTHER IDENTIFICATION SHOWING TI-4E FIRE PROTECTION RATING_ THE LABEL SHALL BE FACTORY APPLIED, WHERE FABRICATION AND ASSEMBLY ARE DONE. INSPECTION SHALL BE MADE BY AN APPROVED INSPECTION AGENCY DURING FABRICATION AND ASSEMBLY, UNIFORM BUILDING CODE No. 43 -1_ 28. ALL GAUGES SHALL BE LIQUID FILLED. 29. IT I5 RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO PROVIDE FIRE STOPPING FOR ALL FIRE RATED PENETRATIONS. • 11 • hill sommirmin r 111=1=11 MIME ■.■ P Miler; 11111110110 =EMI • SEPARATE PERMIT REQUIRED FOR; Mechanigl Sr Electrical *Plumbing Gas Piping City of Tukwila LLUll -DING DIVISION FILE COPY Pena Pio, Plar review approval is RAW to ansa and omission& � of ��� not authorize heviolation tfany adopted code or a: a; °j• r Receipt Cfty of : F a BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 O 08 Of Tukwila r: DIVI .I N REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVSON MQLL MOi 285 MAR 17 ?008 P I I; it 1 :bI`N1 EP ■ ARCHITECT: ENGINEER: SEAL: T T SHEET NO. T CORTLAND MORGAN, ARCHITECT, AIA 711 N. Fielder Road Arlington. Texas 76012 PHONE. (8171 636 -5696. FAX. (817) 636 -5699 THE PURDY CONSULTANTS 14850 Montfort Drive Suite 250 Dallas, Texas 75254 IIIEMEIEEEMMiMMfflaNEENMI PROJECT COORDINATOR: HIGHIAND ASSOCIATES 228 East 45th Street New York, NY 10017 (212) 681 -0200 (212) 681 -0201 - fax www.highlandassociates_com New York • New Jersey • Pennsylvania KEY PLAN: AREA OF WORK Ti T T 1 • ISSUED FOR PERMIT REVISION 03.13.08 CONSOLOATION SET ISSUED FOR CONSTRUCTION ISSUED FOR OWNER'S REVIEW ISSUED FOR PERMIT NO. DESCRIPTION 02.20.08 01.17.08 01.07.08 12.20.07 DATE % 1NTERAIAP PROJECT NO. 2007 -072P DATE 12/17/07 DRAWN BY NHS CHECKED BY DMS SCALE AS NOTED M PROJECT: 3355 South 120th Place Tukwila, WA 98168 IMEIREMMEMINIESIMMIE SHEET TITLE PHASE II ■ MECHANICAL LEGEND ABBREVIATIONS AND NOTES kUMIIF1E SC1-IEUL BASIS OF DESIGN: SPEC AIR (FRE-PURCI-EASED) TAG 1 MFR FACE TAG 1 1 DESIGN CFM FAN MINIMUM CFM ENTERING AIR CONDITION LEAVING AIR CONDITION 1 RPM MANIFOLD SI REMARKS 1 LWA ELECTRICAL DATA 1 51-1P DRIVE MOTOR DATA ELECTRICAL DATA VFD USED loPERATING WEIGl -I i (LBS) SERVICE LAT DB C °F) 1 CONTROLS AND NOTES: UNIT MARC MODEL NUMBER AREA AIRFLOW VELOCITY MEDIA al AIR AP C IN UJ . ) DIMENSIONS MODEL/ MANUFACTURER U V/PH /HZ H 1 W I L (IN) RTU 5 -6 ROOF DATA CTR 250 2250 44500 SQ. FT. (CFM) (FPM) EFF. (%) DB °F WB °F GRAINS DB °F WB °F GRAINS W 26 N D 30 460/3/60 ODP HUM 5 -6 TT424015400DA 85 44500 521 15% 4951 49.11 53 51 46.8 40 120 61.0 I 110 58 59,3 X55 HUM 5 -1 TTA2405400DA 85 44000 521 19% 4951 49.11 53 1 51 46.8 40 120 250 110 58 1.5 (2) 30 HUM 5 -8 TTA2406400D4 85 44,800 521 19% 4951 49.11 53 51 46.3 40 120 30 110 58 SEE NOTES RTU 5 -9 HUM 5 -9 TT424015400D4 85 44,800 521 19%° 4951 49.11 53 51 468 40 120 593 110 58 30 26 HUM 5 -10 TTA2405400DA 85 44500 521 15% 4951 45.11 53 51 4613 40 120 15 110 58 14.5 61.0 HUM 5 -11 TTA2405400DA 85 44,500 521 19% 4951 45.11 53 51 468 40 120 SXHGD134 110 58 DATA CTR 250 NOTES ..Fa 15 (2) 30 L MINIMUM REQUIRED EFFECTIVENESS IS 1E% 8. HUM SIDIFIER W /55 CASING 4 DRAIN PAN, COPPER DIST_ PIPING, SAL. 61.0 496 2. PROVIDE S" GLACIERCOR STANDARD EFFICIENCY MEDIA YALYE, EDGE COATING ON MEDIA, OVERFLOW, DRAIN 1 BLEED, CURB 593 155 3. PRESSURE DROP 0.19 INWG TO MATCH ACU, LOW WATER CUTOF ,, CIF', RUNL FGI -IT, HOA SWITCH, 30 26 4. STAINLESS STEEL CASING AND DRAIN PAN FACTORY WIRED, HOSE SIBS, WATER PROOF INSTUALTION 65 .30 5. INTERNAL SUMP PUMP, FLOAT VALVE, BLEED VALVE AND PIPING 82X141X424 5X1-1GD134 6. MAKEUP WATER AND BLEED CONNECTION THROUGH SIDE OF UNIT 1. LOCATE ELECTRICAL PANEL ON SIDE OF HUM 51DIFIER ACCESSIBLE PER ELECCODE I EXI-4AUST F,AN SCHEDULE ANDL ING UNITS SC4ULE (E-FUC14ASW) !BASIS OF DESIGN: TRANE TAG 1 MFR 1 MODEL TAG 1 1 DESIGN CFM FAN MINIMUM CFM 1 FAN MAXIMUM CFM TSP IN WG 1 RPM 1 TIP SPEED PRE - FILTERS 1 LWA ELECTRICAL DATA 1 51-1P DRIVE MOTOR DATA ELECTRICAL DATA VFD USED loPERATING WEIGl -I i (LBS) SERVICE LAT DB C °F) 1 CONTROLS AND NOTES: I-1.P. , TYPE , VOLTS PIN HZ TYPE al AIR AP C IN UJ . ) DIMENSIONS MODEL/ MANUFACTURER U V/PH /HZ H 1 W I L (IN) RTU 5 -6 ROOF DATA CTR 250 2250 44500 1.5 (2) 30 1460 / 1212 145 61.0 49.6 49.1 5 155 PLEAT 30 26 CARTRIDGE 65 30 460/3/60 ODP 82X141X424 5X14GDI34 RTU 5 -1 ROOF DATA CTR 250 2250 44800 15 (2) 30 1460 / 1212 14.5 61.0 49.6 45.1 59,3 X55 PLEAT 30 26 CARTRIDGE 65 30 460/3/60 ODP 82X141X424 SXHGD134 RTU 5 -8 ROOF DATA CTR 250 2250 44800 1.5 (2) 30 1460 / 1212 145 61.0 49b 49.1 593 155 PLEAT 30 26 CARTRIDGE 65 30 AIR ANDL ING UNITS SC4ULE (E-FUC14ASW) !BASIS OF DESIGN: TRANE TAG LOCATION SERVICE MIN 0/A (CFM) MAX 0/A (CFM) SUPPLY FAN COOLING COIL PRE - FILTERS FINAL- FILTER'S ELECTRICAL DATA AIR HANDLER DATA FLOW CCFM) ESP C (N l�J.C.) MOTOR (HP) CAPACITY TTL/SEN5 (MBI --I) EAT D5 C °F) EAT WB C °F) LAT DB C °F) LAT WB C °F) FACE AREA (SQFT) AIR VELOCITY (FPM) TYFE A °P C (N UJ . TYPE al AIR AP C IN UJ . ) DIMENSIONS MODEL/ MANUFACTURER U V/PH /HZ H 1 W I L (IN) RTU 5 -6 ROOF DATA CTR 250 2250 44500 1.5 (2) 30 1460 / 1212 145 61.0 49.6 49.1 5 155 PLEAT 30 26 CARTRIDGE 65 30 460/3/60 ODP 82X141X424 5X14GDI34 RTU 5 -1 ROOF DATA CTR 250 2250 44800 15 (2) 30 1460 / 1212 14.5 61.0 49.6 45.1 59,3 X55 PLEAT 30 26 CARTRIDGE 65 30 460/3/60 ODP 82X141X424 SXHGD134 RTU 5 -8 ROOF DATA CTR 250 2250 44800 1.5 (2) 30 1460 / 1212 145 61.0 49b 49.1 593 155 PLEAT 30 26 CARTRIDGE 65 30 460/3/60 ODP 82XI41X424 SXHGD134 RTU 5 -9 ROOF DATA CTR 250 2250 44800 15 (2) 30 1460 / 1212 145 61.0 49.6 49.1 593 155 PLEAT 30 26 CARTRIDGE 65 .30 460/3/60 ODP S2X141X424 SXHGD134 RTU 5 -10 ROOF DATA CTR 250 2250 44800 15 (2) 30 1460 / 1212 14.5 61.0 49.6 49.1 593 155 PLEAT 30 26 CARTRIDGE 65 30 460/3/60 ODP 82X141X424 SXHGD134 RTU 5 -I1 ROOF DATA CTR 250 2250 44500 15 (2) 30 1460 / 1212 145 61.0 496 49.1 593 155 PLEAT 30 26 CARTRIDGE 65 .30 460/3/60 ODP 82X141X424 5X1-1GD134 A. GENERAL: IT 15 THE INTENT OF THESE SPECIFICATIONS TO DUPLICATE, EXCEPT WHERE NOTED OTHERWISE, THE CONTROL, MONITORING, AND ALARM SYSTEM OF TI-4E MECHANICAL AND ELECTRICAL SYSTEMS PRESENTLY INSTALLED FOR PHASE ONE OF THIS SITE AS FURTHER DESCRIBED HEREIN OR 51-4OWN ON DRAWINGS FOR THE NEW PHASE 2 INSTALLATION. 1. NEW COMPUTER GRAPHICS AND DATA DISPLAY TO MATCH THE EXISTING SYSTEM GRAPHICS FOR ALL NEW MECHANICAL, ELECTRICAL AND FIRE PROTECTION EQUIPMENT SHALL BE ADDED TO THE BMS_ 2. ALL EQUIPMENT MONITORING, ALARM, AND CONTROL POINTS SHALL BE ADDED TO MATCH THE EXISTING PHASE ONE INSTALLATION POINTS. 3. NEW SUPPLY AIR MODULATING DAMPERS SHALL BE ADDED TO THE EMS CONTROLS AS FURTHER DESCRIBED HEREIN FOR THE NEW INSTALLATION AND AT THE OWNER'S OPTION FOR THE EXISTING PHASE ONE INSTALLATION. B. RTU'S/REL IEF FANS: 1. FIVE (5) NEW ROOF TOP UNITS (RTU) INCLUDING A HUMIDIFIER, AND AT THE OPTION OF THE OWNER A SIXTH (6TH) RTU, WILL BE INSTALLED ON THE ROOF TO MATCH THE EXISTING INSTALLATION FOR PHASE ONE. THREE (3) NEW AIR RELIEF FANS WILL BE INSTALLED SIMILAR TO THE EXISTING INSTALLATION. REFER TO DRAWINGS FOR LOCATION OF NEW UNITS. 2. THE RTU AND HUMIDIFIERS SHALL BE MONITORED AND CONTROLLED IN THE SAME MANNER AS THE EXISTING RTU'S WITH THE FOLLOWING EXCEPTION: A. EACH NEW AND EXISTING RTU WILL INCLUDE THE TRANE GRAS CONTROL MODULE TO PERMIT FULL UNIT CONTROL AND MONITORING FROM THE REMOTE 5M5 STATION. EXISTING BTU'S SHALL HAVE THE CONTROL SYSTEM MODIFIED TO ACCORDANCE WITH THIS SPECIFICATION 60 THAT ALL BTU'S FUNCTION IN THE SAME MANNER 5. THE RTU SUPPLY AIR TEMPERATURES SHALL BE RESET BASED UPON THE DATA ROOM TEMPERATURE SET PONT. C. REDUCTION OF RTU SUPPLY AIR QUANTITY SHALL BE SEQUENCED WITH THE CHANGE IN SUPPLY AIR TEMPERATURE. D. USE OF OUTDOOR AIR FOR "FREE COOLING" SHALL BE USED WHENEVER OUTDOOR AIR CONDITIONS ARE CAPABLE OF PROVIDING COOLING TO MEET THE ROOM SET POINT TEMPERATURE CONDITION. E. RELIEF AfR FANS SHALL BE CONTROLLED VIA STATIC PRESSURE ROOM SENSORS TO MAINTAIN A SET PRESSURE DIFFERENTIAL BETWEEN THE RAISED FLOOR PLENUM, EQUIPMENT ROOM, AND EXTERIOR ATMOSFI -IERE AS PREVIOUSLY SPECIFIED FOR PHASE ONE. F. THREE (3) RELIEF FANS WILL BE USED TO PROVIDE PHASE II AIR PRESSURE CONTROL. THE FANS WILL BE MODULATED YIA NEW VFD'S (WATERPROOF FOR OUTDOOR INSTALLATION) FOR MOUNTING AT THE FANS SIMILAR TO THE EXISTING RELIEF FAN INSTALLATION. G. FINAL OPERATING CONDITION OF RELIEF FANS SHALL BE DETERMINED BASED UPON ACTUAL SOUND LEVELS. H. RTU DISCHARGE AIR TEMPERATURE AND HUMIDIFIER CONTROL SHALL BE SET TO MAINTAIN THE AREA SPACE TEMPERATURE /HUMIDITY LEVEL YIA THE AVERAGE OF THREE (3) AREA SPACE SENSORS. DISCHARGE AIR TEMPERATURE FROM EACH RTU AND HUMIDITY LEVEL SHALL BE SET IDENTICAL. C. SUPPLY AIR DUCT DAMPERS: AUTOMATIC TEMPERATURE CONTROL SEQUENCE OF OPERATION 1. NEW SUPPLY AIR DUCT DAMPERS 51-1ALL BE CONTROLLED SY LOCAL SPACE SENSORS AS SHoWN ON THE DRAWINGS. 2. UPON A RISE IN TEMPERATURE ABOVE SET POINT, THE ASSOCIATED DAMPERS SHALL MODULATE TO SUPPLY INCREASED AIR INTO THE RAISED FLOOR. 3. OPENING OF THE SUPPLY AIR DAMPERS TO 100% AND SENSOR SET POINT NOT ACHIEVED SHALL RESULT IN THE RTU DISCHARGE AIR QUANTITY TO INCREASE AND IF NECESSARY DISCHARGE AIR TEMPERATURE TO BE LOWERED TO ACHIEVE THERMOSTAT SET POINT_ 4. THE DAMPERS SHALL BE SET TO MAINTAIN A MINIMUM AIR QUANTITY, ADJUSTABLE AT THE BMS TO BE DETERMINED DURING COMMISSIONING OF THE SYSTEM. 5. SYSTEM PRESSURE CONTROL SHALL FIRST MODULATE RELIEF AIR QUANTITY TO MAINTAIN AIR PRESSURE SET POINT WITHIN THE ABOVE FLOOR SPACE TO MATCH AIR PRESSURE MAINTAINED IN ABOVE FLOOR SPACE OF PHASE 1 WITHOUT CHANGING SUPPLY AIR QUANTITY OR CONDITION. 6. PROVIDE MOTOR ACTUATORS FOR THE EXISTING SUPPLY AIR DUCT DAMPERS LOCATED IN PHASE 1 SPACE. THE DAMPERS SHALL BE CONTROLLED AS DESCRIBED FOR PHASE I1. D. HUMIDIFIERS: 1. HUMIDIFIER DISCHARGE ISOLATION DAMPERS 51-1ALL BE INTERCONNECTED WITH THE ASSOCIATED RTU 50 THAT UPON A GALL FOR THE RTU TO START THE HUMIDIFIER DAMPER SHALL OPEN, AND CLOSE WHEN THE RTU STOPS_ PROVIDE AN ACTUATOR PROVING SWITCH OR POSITIVE FEED -BACK TO MONITOR THE POSITION OF THE DAMPER 2. NEW HUMIDIFIERS SHALL INCORPORATE ALL CONTROLS SIMILAR TO THE EXISTING PHASE ONE INSTALLATION. E. HUNG CEILING DUCT LEAK DETECTION: LEAK DETECTION SHALL BE INSTALLED WITHIN ALL NEW DRIP PANS INSTALLED BENEATH NEW DUCTWORK WITHIN THE HUNG CEILING AREA OF THE SPACE. THE DETECTION SYSTEM SHALL BE MONITORED BY THE EXISTING BMS AND ANNUNCIATE ALARMS AS PRESENTLY ARRANGED. F. ELECTRIC NEAT TRACING: PROVIDE ELECTRIC HEAT TRACING FOR THE MAKE -UP WATER PIPING TO EACH HUMIDIFIER ON THE ROOF. HEAT TRACING TO MATCH INSTALLATION AND MANUFACTURER OF EQUIPMENT USED FOR PHASE I. G. SYSTEM SAFETIES: 1. PROVIDE FOR EACH RTU A HIGH PRESSURE DISCHARGE STATIC PRESSURE SENSOR TO AUTOMATICALLY SHUT DOWN ITS' UNIT OPERATION UPON A DISCHARGE STATIC PRESSURE TO BE DETERMINED DURING COMMISSIONING. DISCHARGE SENSOR TO BE LOCATED BETWEEN THE RTU DISCHARGE AND HUMIDIFIER ISOLATION DAMPER SET -POINT WILL BE APPROXIMATELY 050 IN. W. ABOVE NORMAL DISCHARGE PRESSURE, SUT NOT IN EXCESS OF DUCT OR RTU MAXIMUM PRESSURE. H. ELECTRICAL SYSTEMS: 1. NEW ELECTRICAL DEVICES AND SYSTEMS SHALL BE MONITORED AND ALARMED IN THE SAME MANNER AS THE EXISTING SYSTEMS_ I. UNDER FLOOR AIR TRANSFER OPENINGS 1. PROVIDE DAMPER ACTUATORS FOR EACH UNDER FLOOR OPENING AS SHOWN ON DRAWINGS, 15 IN TOTAL. 2. ACTUATORS SHALL BE NORMALLY CLOSED AND OPEN BASED UPON UNDER FLoQR DEGREASE IN STATIC PRESSURE BELOW NORMAL SET POINT. PROVIDE TIME DELAY (ADJUSTABLE) TO PERMIT MINOR VARIATION IN PRESSURE DUE TO SUPPLY AIR DAMPER AND RELIEF FAN MODULATION. 3. STATIC PRESSURE WITHIN PHASE I AND 11 SHALL BE MAINTAINED AS DESCRIBED IN "C" ABOVE. - .. - \.- „ ,. ,i ., ., - ,. -- ,-- ,r \• L EXHAUST FAN SELECTIONS TO BE SUBMITTED 5Y CONTRACTOR AND FILLED IN ONCE SELECTION 15 COMLPETED. REVIEWED FOR CODE COMPLIANCE APPROVED MA R <� 1 � 2�a8 +pit Of Tul�w1 G P a N7' a MAR 1 1 608 PEE3ivk 11 - f . �,� • • INEEMSEIMMENEMEEMEMEMI ARCHITECT: CORTLAND MORGAN, ARCHITECT, AIA 711 N. Fielder Road Arlington, Texas 76012 PHONE. (817) 636 -5696, FAX. (817) 636 -5699 ENGINEER: PROJECT COORDINATOR: HIGHLAND ASSOCIATES 228 East 45th Street New York, NY 10017 (212) 681-0200 (212) 681 -0201 - fax www.highlandassociates.com New York • New Jersey • Pennsylvania KEY PLAN: AREA OF WORK ■■■■ ■.'®■i■1LIi ■ ■■■ ■ ■ 1I •■■ ■''' _ ■ ■■� �■ ■ ■■■ ■ ■■■■■■■i amb = ■■■■■■■■e srin . ■ ■■■■ ■■■II ■ I ■■■■■■■■ii•m�i■■S ■ ■■■■■ ■■■s ■ ! ■ ■ :gyp ■■■ ■■ii ■ ■■■■■■ t �-� =mums ■■ ■L, ■■ ■■■■■■ ■■■ I■!..? !!■ ■■ ■■■ ■■■hI'E ISSUED FOR PERMIT NO. DESCRIPTION PROJECT: THE PURDY CONSULTANTS 14850 Montfort Drive Suite 250 Dallas, Texas 75254 T T I T I T ISSUED FOR PERMIT REVISION 03.13.08 CONSOLIDATION SET 02.20.08 ISSUED FOR CONSTRUCTION 01.17.08 ISSUED FOR OWNER'S REVIEW 01.07.08 M-1 12.20.07 DATE I1V'IERIVi?ux' 3355 South 120th Place Tukwila, WA 98168 PROJECT NO. 2007 -536 DATE 12/20/07 DRAWN BY STAFF CHECKED BY CMA SCALE NOT APPLICABLE SHEET TITLE MECHANICAL SCHEDULES AND SEQUENCE OF OPERATIONS PHASE 11 wimmumsommaiimm SHEET NO. 1 • s • • • \ „. • N N • , , • • \ \ \ • \ N \ \ \ • \ \ • \ • • • \ \ \ \ \ „‘„ \ \ .\\ \ \ \ ‘ N, ‘„ \, \ \‘‘. \\\ \\ ‘• \\•\ ' 11 \\, \\ i• \\\\\ \ N \ \ \ , \ ,\ \ \ \ \ \ \ \ \ \\ \ \ PO , Lag Tc? 5 •\,\ \ • . \ \ \ ‘„, \ \ • \ \ \ \ • - \ • \ \ \ •., M•'- SCALE k =II \ 1 II 1 ' ., FAo,r Rbo„1-1•0,UNITED , , , I ■ • DUCTWO*.- . 5 s OWINI TO \‘' ■ `, • 1BELoui% F.:AteE0\.Lopfe._ eri \ \ . • ' .. .. . „ . \TR AIR IDIS I E)L I 10\ NOTE: DENOTES TEPERATURE SENSOR FOR AUTOMATIC DAMPER CONTROL VIA BMS OUTPUT SIGNAL. =0 DENOTES MOTOR OPERATED DAMPER BELOW REAISED FLOOR (QUANITY (15): 36 "W X 18"1-1) ANICAL: DATA ELECTRICAL FROOM f rz=it ‘• \ „ ,‘ „, • \ \ „ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \s ` ‘ \ \ \\ \ \\ \ \ \\ \ \ \ \ „ s ‘ ..„ ‘. •„\\\\ • N (181) 2424 55% OPEN PERFOF.ATED FLOOR — ILE REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 () 2008 City of Tukwila I DING DIVISI011_ MAR 1 7 2008 PEh 1N fER L. MUMMENEMENEER ARCHITECT: CORTLAND HORS” ARCHITECT, AIA 711 N. Fielder Road Arlington. Texas 76012 PHONE. (817) 636-5696, FAX. (817) 636-5699 INEMENIEMEIIMINEZUSENIMINna ENGINEER: THE PURDY CONSULTANTS 14850 Montfort Drive Suite 250 Dallas, Texas 75254 111111161111MMENI PROJECT COORDINATOR: HIGHLAND ASSOCIATES 228 East 45th Street New York, NY 10017 (212) 681-0200 (212) 681-0201 — fax www.highlandassociates.com New York • New Jersey • Pennsylvania MMEEMMENEEKEMMOMMI KEY PLAN: AREA OF WORK • muss MO MIMI= MEM 111111K41111111111111=111 NM ME liffirallIMUM ME ME IIMME_MINIMMI JillnaliMia NNE NUMMI inlIMMINEM 1011111••111H IMINU11111110111111n11Wir UUIIIIIIIURIIUf!ji 111111111111111 TtiTi' 11 7 PROJECT: PROJECT NO, DATE DRAWN BY CHECKED BY DS SCALE SHEET TITLE SHEET NQ. 2007-536 12/17/07 NHS 1/8" = 1' PHASE 11 ISSUED FOR PERMIT REVISION 0313.08 ISSUED FOR PERMIT REVISION CONSOUDATION SET O220.08 ISSUED FOR CONSTRUCTION 01.17.08 ISSUED FOR OWNER'S REVIEW 01.07.08 ISSUED FOR PERMIT 12.20.07 NO. DESCRIPTION DATE MECHANICAL DATA CENTER AIR DISTRIBUTION nisiTERNApa 3355 South 120th Place Tukwila, WA 98168 M111.1111111111111112111111111111111111MINIMMI \ \\ \\ \ \\\\\N \ \\\\.\\\\\\ \`\\, \\ \ \\ \ \ \ \ \ \.\ • \ \ ` . \ \ . • .\ \ \' t \ \. \ \ \ a \ � ` , \ \`. \ \ ` `\ \ \ , ` \\ \\ \ \ \ \ \ \ \ \ \ - \ \ \ \\ \ \ • \``. \ \ \ \ \\ \ \' • \! \ \ \ `\ \ \ \ \ I(' \ ` \ \\ \ \ \\ `\ \ \ \ \ \,\ \ \ \ \ • \ \ \, \ \ f \` \� \\ • \ 4 , 40X40 iI6 ■T■ 44x18 SUPPLY DUCT FROM ROOF MOUNTED DUCTWORK DOWN TO BELOW RAISED FLOOR CTYP) \I`\ \ ` \ \ \ \ \ \ • . ,1 26X40 26X40 40x40 SUPPLY DUC FROM ROOF, 40X40 1 1 \ \ \ , \ \ \ \\ \ y \ \ \ �i \ \ \`. 18 a�IPh LY`, \'� \. \ \ \ \ \ \ \ \ \ \ \ � \ \ \ \ \. \\.\\\:\ \ \ \\\ \ \ \ N \ \ \ \\\ ..\/\\ \\\\ \\.\/ \.\\ \ \ \\\\ \ \\\ \1\ \ N \\\\\ \\, \ .\\,\\ \ N \I "- 7 \\\\\ \\\ \ \\\\\:\,_\ \\\•\ \ \ \ \ .\ \\__\ \ _ ?_i, -.. ma •, a�� t< . �`T - 'r.`.° n���z' Tv' vrtd" . k •- !°`� ^.. '°e . "a _ ° , " - 5'G'i� ... e f�' r ^ i = `L:'we' .. �3?� s .. r • l 28X36 40x40 • ► 11111 ®I M 40X26 40X26 M MIZIOpPME11.1111 ISX4 -- : T\ I\ N •ti. 111 ®1► � 40x40 DATA Cl • 18X44 :.,w;.::, ...- DAT4 CENTER 40x40 SCALE: s" = li -0 40x40 T ®111118X44 I 40X26 40X40 SA DN 40X2rc r l^il \ \ \ J - I \ \ \ I• WTS 64X46 EXHAUST UP `+, \I \ V \ \\'' I \ \ ' _. __ �� — - - te I � I 1_... I �.. nF 4- rt -- 1 T I f—,-.7-----F 1 . - .�._. T 1 1 1 � T i t i \\ .I \ — - -- -=\ r 7 1 ( t T — • f -- -- -- _ _ � _ - T - # --� -• - \ ` 1 I\ \ I I ! i _1 I [ : _ r 64X46 EXHAUST UP. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 () 2008 City Of Tukwila ILD 3 MAR 1 l 2008 L;Eb TER MENMEMENNOMMEEMEMI ARCHITECT: CORTLAND MORGAN, ARCHITECT, ALA 711 N. Fielder Road Arlington, Texas 76012 PHONE. (817) 636 -5696, FAX. (817) 636 -5699 INEMEMINSINSEMIMSEMEVEN ENGINEER: THE PURDY CONSULTANTS 14850 Montfort Drive Suite 250 Dallas, Te xas 75254 iiiiiiiiiMMOMMINNOMEMENEMEN PROJECT COORDINATOR: HIGHLA \D ASSOCIATES 228 East 45th Street New York, NY 10017 (212) 681-0200 (212) 681 -0201 — fax www.highlandassociates.com New York • New Jersey • Pennsylvania KEY PLAN: AREA OF WORK T i T T T PROJECT: SHEET NO. ISSUED FOR PERMIT REVISION 03.13.08 CONSOLIDATION SET UPDATE 03 07.08 ISSUED FOR CONSTRUCTION ISSUED FOR OWNER'S REVIEW ISSUED FOR PERMIT NO. DESCRIPTION 01.17.08 01.07.08 12.20.07 DATE 1 pf-A3 �:. INTERNAP° 3355 South 120th Place Tukwila, WA 98168 PROJECT NO. DATE DRAWN BY CHECKED BY CMA SCALE 1/8" = 1' 2007 -536 12/17/07 STAFF iniMENNEERMIEMEMIE SHEET TITLE MECHANICAL DATA CENTER DUCTWORK LAYOUT PHASE 11 Ll -3 IIMIMMEEMBEEEINEMI f 000 F661 1 i RTU 5-11 _00 ?4X109 OPENING (TYP.) RTU 5 -1 ee F661 I' ■ I' IP - (L ) I N I SA DISCHARGE DUCT CONNECT TO HUMIDIFIER HOUSING, ADD 105X80 SA DUCT FROM HUMIDIFIER TO MAIN 94 "O DUCT (TYP.) SECURITY BARS (TYP.) 48X48 OPENING. 44X44 SUPPLY DUCT DOWN TO DATA CENTER (TYP_) • s { 4 E - Ire- -- I * R GEF 5 -5 . /. J I . L ,. - '• • a. L I EXISTING AC 5 -1 TEE FITTING WITH TWO ?0X36 EXHAUST OUTLETS. ?4X54 ROOF OPENING. (TYP. FOR 2) HUM 5 -10 I�IN mow !I 11 ®I I' _. - - -- ■1 1 I.11■1 I�I�11 ■•••, w4 . ` -, DTI vi 1i i ,._ HUM 5 -6 OMNI! A R. Ems/ MTI r ' I rice WANE RTU 5 -10 HUM 5 -8 RTU 5 -S RTU 5 -9 RTU 5 -6 1 EXISTING it • FT a 5 " I K I ; EXISTING' RT'U 5 -3 E X I S T I rLlG NUM 5 -3 4 1 1pa VEC1AANIC,4L: GOOF ELJI SCALE : S" = 1 - " EXISTING Nui15 -2 EXISTING RTU 5 -2 EXISTING- . • EXISTING RTU 5 -5 EXISTING HUM 5 -5 f W O 0 O 0 O Q II 1 E %iSTING I C E- 5_2_, L AN EXISTING ING F /.IST!NG .1CCU..S. -4. - `CCU. 3 -3. EXISTING HUM 5 -1 EXISTING RTU 5 -1 E,!STING E /!STING %cOU .5-1 LV I i 1 EXISTING I 1 • EXISTING NUr1 5-4 EXISTING RTU 5 -4 s • • t �1l\ falk veJ �-r • 50 INCs. ST • 3 BACKDRAF;T DAMPER .1 (TYP. FOR 1 EXHAUSTS) 4 1 9 • BIRD WIRE MESH SCREEN (TYP. FOR EXHAUSTS) REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 0 2808 City Of Tukwila I .: � I 1 DIVI.:: ION .. ! sue,., e MAR 17 2008 PEh 'i y Gicj 19 ER ARCHITECT: CORTLAND MORGAN, ARCHITECT, AIA 711 N. Fielder Road Arlington, Texas 76012 PHONE. (8171 636 -5696, FAX. (8171 636 -5699 IMINEETEINIMMENESERMEMESS ENGINEER: THE PURDY CONSULTANTS 14850 Montfort Drive Suite 250 Dallas, Texas 75254 PROJECT COORDINATOR: IGHL A1ND ASSOCIATES 228 East 45th Street New York, NY 10017 (212) 681-0200 (212) 681 -0201 — fax www.highlandassociates.com New York • New Jersey • Pennsylvania KEY PLAN: AREA OF WORK A ■■■■ ■■■■ •im■■■i ''':il'■rii' ■v ■ ■■■aI#■■■ ■■■■■■■■Ii■■■ ■Ci■■■ ■■ ■■ ■■■■■■�■■■■s ■■ 1111111111111111111MITI ■■■■■■n■�■■■u ,.L ■■■■i.■■■■■ ■■ I■ •_r 31111111111111innin SEAL: 11 T PROJECT: ISSUED FOR PERMIT REVISION 03.13.08 CONSOLIDATION SET UPDATE 03 07.08 ISSUED FOR CONSTRUCTION 01.17.08 ISSUED FOR OWNER'S REVIEW 01.07,08 ISSUED FOR PERMIT NO, DESCRIPTION 12.20.07 DATE k lAlTERNAP° 3355 South 120th Place Tukwila, WA 98168 PROJECT NO. 2007 -536 DATE 03/01/07 DRAWN BY NHS CHECKED BY DMS SCALE 1/8 ; 1' SHEET TITLE MECHANICAL ROOF EQUIPMENT LAYOUT PLAN PHASE II antousummammmu SHEET NO. M-4 (t:/: W 1 (AN g -............c....,. RTLJ 5-5 • CONNECT TO EXISTING CUJ SUPPLY LINE f><1 ^ N EISTING PRY AND IBACKFLOW ASSEMBLY 3" EXISTING CW-DN THRLI ROOF 2" CW (HUMID(FIER LINE) GEF 5 - 1\, / It, 0 SCALE 111.1' L rf \ / ("1 Aw..9 (A R% (A% W EXISTING AG 5-1 2 DRAIN DOWN HUM 5-10 RTU 5-11 2" -CZ-- (1-IUMID (F(ER LINE) EXISTING 3 11 CW HUM 5-11 RTU 5-10 EXISTNG S-3 2" DRAIN •W.- •■••■• EXIST ING RTILI - (A% 2" DRAIN gs% W..Y1 AMC/AL: R00 - FIFI 2" CW I 1 A HUM 5-5 2" DRAIN E><ISTING HUM 5- 2 EXISTING RTU 5 - 2 RTU 5-`a r 1 I-IUM 5-S EXISTING RTU 5-5 3 it CW EXISTING HUM 5 -5 2" FUTURE (AK% , (AK% v4:1 'WV (AL% W (A% (A% Ah Mr/ DRAIN ..% 3 ct) (AK% JENIONINIME HUM 5-67 2" DR4 7N RTU 5-6 EXISTING; RTU 5- 1 E X I ST INC-, HUM 5 - I-4U1 RTU 5-1 (fa\ EXISTING EX' / ••• !STING . ................ 1 7 .7 1 ! I I E x I CT I NC L.- - ■ - 1 - T --• ExIS TI NG -UM 5 - 4 • EXIST I NC RTU 5 - 4 6 'CY VW WEV 4 -3P Wif I 1 3 4" CW 1 2" DRAIN • 1 • - • - -- • - _ • • - • 1 • • •• _ • -1 --•-• -- • - • • FI-1ASE 11 PHASE 1 (EXIST1N) REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 0 2008 City Of Tukwila B I /I . DIVISION • 'r MAR • 7 2008 PEHv ULNTEFi ARCHITECT: CORTLAND MORGAN, ARCHITECT, AIA 711 N. Fielder Road Arlington, Texas 76012 PHONE. (8171 636-5696, FAX. (8171 636-6699 SENEEMBIOREMENEMENIMMEMI ENGINEER: TIE PURDY CONSULTANTS 14850 Montfort Drive Suite 250 Dallas, Texas 75254 1111111111112/111111111 PROJECT COORDINATOR: HIGHLAND ASSOCIATES 228 East 45th Street New York, NY 10017 (212) 681-0200 (212) 681-0201 - fax www.highlandassociates.com New York • New Jersey • Pennsylvania KEY PLAN: AREA OF WORK Min EMILIMININ INEMENtemmuM MUNI 1 .- 11 .-MINIIM MEM! 1111,811EW 214 2220 IBIEWEE-1111121a •EMIIIMMINIMIIMEAM MENNE 11101111111r111111111111lowl mom miumwrin INE1111111111111101 • T T if TIT 1111111111111111111111MINNENNIRSIBINEI ISSUED FOR PERMIT REVISION 03.13 08 ISSUED FOR PERMIT REVISION CONSOLDATION SET 02.20.08 ISSUED FOR CONSTRUCTION 01.17.08 ISSUED FOR OWNER'S REVIEW 01.07.08 ISSUED FOR PERMIT 12.20.07 NO. DESCRIPTION DATE PROJECT: INTERNAP° 3355 South 120th Place Tukwila, WA 98168 PROJECT NO. 2007-536 DATE 12/20/07 DRAWN BY STAFF CHECKED BY CMA SCALE 1/8" .7.1' SHEET TITLE MECHANICAL ROOF EQUIPMENT PIPING PLAN PHASE II ismommimmunimams. SHEET NO. 'VI SUPPOTS ,�` ,.....-01—.... ` 4a" WELD OR BOLT FRAME TO INSIDE OF EQUIP. CURB \ GYPBOARD SUPPLY AIR SHAFT WALL, TERMINATE GYPBOARD 2" BELOW AND OR DUCT " GH D FLOOR :;;: (AS REQUfRED) vAV g/ _- SHEET M TAB SCREW 1 ;TRAP TO BOA:" SEAL � AlRTICx1 -IT (TYP) ' T PICAL ' ,3/1+'0" WELDT RU OUT DUCT TRANSfTl01 1 /2' D1A 1018 COLD STEEL B ARS. 11JELD INTERSECTION ROLLED i '� ' ° � i OPENING DUCT AND SHAFT BETWEEN WALL EXTEND CONCRETE ARCH. METAL STUDS TO FLOOR SEE DWCs'S FOR DETAILS CONCRETE FLOOR ---....,_ ,r FL AIR ; L \ . - -/ I 1 J �` � �' I IN �A'�iP• � d \ v 1 H{ �� PRESSURE FLEX DUCT". 3 FEET MAXIMUM. ROUND DUC / 4I -0" MIN. OF LINED I'DUC- -J j / ' . / AT E�4GI -1 I "x1/4" WELD SECURITY --` REuEAT COIL CONI", NOTE: 0 OL 3 O-X PROVIDE SEISMIC SEE SPECIFICATIONS /A - REF - IERACENC1 AT ALL VAV aOXES. FOR SEISMIC DESIGN CRITERIA, 1'INAL 5.0X 5LIF OF T NOTE: FLAT BAR FRAME ADD THIS BURGULAR BAR ASSEMBLY DUC`� /S � TERMINATION DETAIL RODS TO FRAM C TO ALL ROOF OPENINGS, LARGER THAN 1.0 SQ. FT. IN SIZE AS5 1�IBL�" Scale: NONE Scale: NONE Scales: NONE 1 FOAM GASKET N �. ' i ,, N 7' N. MAIN ON OP OF CUIR GALV. SHEETMETAL 3 CAP. SEE ARCH FASTEN FLASHING TO CANT N OR NAILER, SEE ARCH. DWG'S FOR DETAILS FLASHING, SEE ARCH. FOR DETAILS 2X FIRE RETARDANT 1t/ 3 1/4 --` '., TACK WELD 6" O.G. DWG'S FOR DETAILS — — FOAM GASKET ON TOP OF CURB VFD W/FUSED DISCONNECT � IN NEMA 3R CABINET. FIELD MOUNTED ON FAN OR RACK SEE ELECT. DWG'S. 1 RDWD NAILER \ STEEL BEAM, FASTEN S ST CONCRETE ROE CONCRETE RC a. c� r - N1 J CANT, SEE ARCH. DWG S FOR DETAILS BUILT -UP ROOFING ■ I �� 1 - I I _ INSTALL CONTROL DAMPS INSIDE ROOF CURB. FASTEN FLASHING TO CANT PROVIDE ACCESS IN CURB FOR DAMPER ACTUATOR // /I��. N ARCH. OR NAILER, SE R H- DWG 5 FOR DETAILS FLASHING:, SEE ARCH. ,, . • • " q 4 • ; p • ., ®I 2 i/4 R 4 - • • . I o 0 0 0 n FACTORY I �I ` ��` " :` 45_ • 1 I Z °&. N N 24 GAUGE P .. CURB SI -4AFT FOR 2ND FLOOR 6X4 FIRE RETARDANT ! LEVELING CURB. CONTRACTOR HAS / ' M L / / / / / / DWG 'S FOR DETAILS CANT SEE ARCH. / / / ANCHOR NAILER TO GONG. ROOF �� , �, 4 1/2 R TRAILING EDGE $ MOUNT i3URGULAR BARS IN DUCT. STOP DUCT AT BOTTOM OF ROOF DECK OPTION TO USE STEEL ROOFING 7 DW G S FOR DETAILS BUILT -UP ROOFING qtr " SEE STRUGT, a NOT .�- DUCT PENETRATIONS AIR AND WATER TIGHT DWG'S FOR FLASHING, AND CURB DETAILS AF I AT FOnF r.I I -'P 1--) P L I I 1 u 2 1/4" n _ 4 • : • I o n o 0 0 0 n J A I. SEAL ALL 2. SEE ARCHITECTURAL SUPPLY 5 p • Q . 2 1/4" BURGULAR BARS MOUNTED IN ROOF CONCRETE ROOF OPENING SUPPORT STRAP �c ur_________ 24" CLEAR DA 2" I RELIEF E XI —I4UST FAN DETAIL ALUMINIUM DRIP PAN NOTE: SEE ARCH. AND STRUCT. DWCx5 FOR ROOF 7 TU N I NG VANE Scale: NONE PENETRATION, FLASHING B ROOFING DETAILS_ Scale: NONE Scale: NONE F%`c,:.7 F •' 1 i:. iN(•ED i I ELF : 01_ iON �A1--1," T IN. iG'E 'UH-T - - -. N� �. �:t. � ,. . I5,!' 7S i 'CC'UNTEt_ !i ... I I N I�-, / ._... — -- — , N; . EX . :Fi .: sip • - MANUFACTURER PROVIDED AG UNIT ROOF CURBS LEVELING CURB CTYP) 120x56x110 72x CONNECT (TYP) (TYP) I �. Li ....j .�I 2,..,.-4 .,14ILE_ - - W_- _..- F.r,4, i.r -, 1 L . . ;ING; T;n r. ,N; OAR N4iI f."�, SE4 .4 r� rfc>_ .': - - =TAILS HUMIDIFIER 6 2 SA DISCHARGE DUCT TO HUMIDIFIER CTYP) BAGKDRAFT DAMPER ' N - I\- �I.C: OFR IIv51D �?C `5 r j Ly T- `'' �`J �11 /, -11- a f` OTI -IE 54.- •-, _.- " i r.r HUMIDIFIER (TYP) —� a 0 F:� C�TD! :. SUPPLIED r r _.. __ ._.. , `\ �.i r i7,.0C''S FOR. DE.TAIL5 f , C4N �•, SEE /4-7..-C1-4. ROOFTOP UNIT (TYP) 40X•0 SA OPENING (TYP) -_""_" _ ,, ; A' E.1 -�', II ° - 1~61, I I .� t1oJN`1�y4; Ct; c -- - - . TO L'C�NC. y�f -Ot t Iry r?:JC' 4.1 i . • \ 1 \ \' "' i -- �.. � �� • W.= TC xY .: ) ; 1 , "..�_.. " s I `E!_ r' �5. C - ROOF ,�w'.. •, �, .1 r - I-' S " I : 1 ~ n om. r I US O 1 "O r W OF I'� ; �` C "- SEE �` - - -' .•� [ / I _ :' _ _ - -_ - \ f , • / '(I,� f / ! /\\/ �i I ', �,G QpENIi�iC 1 I '— CONCRETE iRC G I-�E IL I 1 SEE STRUGT 0 400U F MOUNTING FULL HEIGHT REVIEWED FOR CODE COMPLIANCE APPROVED . j CYPBOARD WALL Scale: NONE T -BAR CEILING (+53' -6 ") NT '_ .."' RAISED _ FLOOR (+42' MAR 2 0 2000 aty Of Tukwila B I _:rI : DIM ION DUCT SIZE. SEE PLANS. - 51 METAL TOGETHER TO BOLT -IEET BANDS POST WITI4 1/2 "1 BOLT (TYP.) 3RD FLOOD_ (+40 -0 ") 1111111 INTO WELD I T5 2x2x3/I6 SLIDE POST AROUND (TYP.) I PROVIDE FLASHING AROUND STEEL POST, CANT AROUND POST, SEAL AND FLASI4 -4 TS 3x3x3/1 WELD POST TO BASE PLATE. (TYP.) ANCHOR SAE PLATE TO � a .J SUPPLY AIR DUC ROUTI 3RD FLOOR DATA CENT R 4 i� .: f. __ r = C F s + I ,'.'I .•: is , _..,. .. f : r� : J. ti `I s • • •, PL 1/4x4x1 TO CONCRETE ROOF_ WATER T1 4T (TI BUILT UP ROOFINGS. 171 g ROUND e , a• a • • e DUCT ROOF SUPPORT p .' •4 a . - CONCRETE ROOF. "" . DETAILS � NONE I �/ Scale: 4 R n,77- MAR 1 PEN ii I r,;c \I ! E Scale: NONE PROJECT COORDINATOR: INERMSEENSEMEEMEEMISIONE ARCHITECT: TTTT CORTLAND MORGAN, ARCHITECT, AIA 711 N. Fielder Road Arlington. Texas 76012 PHONE. (817) 636-5696. FAX. (8171 636• -5699 INEMEMEMINIMMEMMINIEEME ENGINEER: THE PURDY CONSULTANTS 14850 Montfort Drive Suite 250 Dallas, Texas 75254 HIGHLAND ASSOCIATES 228 East 45th Street New York, NY 10017 (212) 681 -0200 (212) 681 -0201 -- fax www.highlandassociates.com New York • New Jersey • Pennsylvania KEY PLAN: AREA OF WORK A ■■.■■■1.ii• ■ ■ ■ ■ ■ ■■ P : ■ ■f�l■ ■ ■■ ■■tiM■■■■■■■■ 11111111 ins ■Iial ►ta EE ■ ■■■ ■ ■ I iiii ■■ ■ ■�i� ■ ■�r_iri •u■ ■i■■ ■a ■■ice ■■i ■ ■■■■ ■ ■ ■■ ii i ■■■�■■■■■■ ■■I ■ MIEEMENIMMIIIMA T T ISSUED FOR PERMIT REVISION 03.13.08 ISSUED FOR PERMIT REVISION ISSUED FOR CONSTRUCTION 01,17.08 ISSUED FOR OWNER'S REVIEW 01.07.08 ISSUED FOR PERMIT 12.20.07 NO. DESCRIPTION DATE PROJECT: 3355 South 120th Place Tukwila, WA 98168 PROJECT NO. 2007 -536 DATE 12/20/07 DRAWN BY STAFF CHECKED BY CMA SCALE AS NOTED SHEET TITLE SHEET NO. MECHANICAL DETAILS PHASE H siammimaiimanimmems M M 11 N RTU -S -6 904 xxx CFM XXX CFM i 4043 CROSS CONNECTION 11 N XXX CFM RTU -S -1 /_\ / / / X>0< CFM XXX CFM 1 DRAIN (TYP) CHEF -S -X \ ,r \ 1 XXX CFM 9043" st;t1 N XXX CFM 404 CROSS CONNECTION RTU -5 -9 xxx CFM XXX CFM 41 FLOW D [AG 4 I GEF -S -X VFD I M i--1 \-„ \ I 90 +" M T 1 RTU -5 -10 XXX CFM XXX CFt'1 0 j GEF -S -X ,1 F-- VFD I Mi -- ` \; ` ! i L�J DRAIN (TYP) XXX CFM xxx C1=M M 11 N RTU -5 -11 900" XXX CFM XXX CFM T n AUTOMATIC CONTROL DAMPER (TYPICAL FOR ALL VERTICAL DROPS) t XXX CFt•1 XXX CFM. 16" UNDERFLOOR TRANSFE=R OPENING (TYP - 15) FLOOR GRILLE (TYPICAL) ACCESS FLOOR 36" ROOF HUNG CEILING BLAB REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 (} 2008 City Of Tukwila BUILD' DIVISION MAR 1 7 2008 PEFiIv s CENT Eli MEMEMEMEMEMENEMBEIBMEE ARCHITECT: CORTLAND MOROAN, ARCHITECT, AIA 711 N. Fielder Road Arlington, Texas 76012 PHONE. (8171 636 -5696, FAX. (8171 636 -5699 ENGINEER: TIE PURDY CONSULTANTS 14850 Montfort Drive Suite 250 Dallas, Texas 75254 PROJECT COORDINATOR: HI ASSOCIATES 228 East 45th Street New York, NY 10017 (212) 681 -0200 (212) 681 -0201 — fax www.highlandassociates.com New York • New Jersey • Pennsylvania KEY PLAN: AREA OF WORK ■i■ , .....■■■■■■ ■■■ •■ �,■■ ■ ■ ■n I■ Rn ■■ ■n •RlI ■ ;M■MMell u — =m ■■■ ri■■■�I■�i•u 1111111111u ■ui■■■■■N•ii ■iiii ■i iMi■Mi ■mss ■IM ■■■■■■ii■■■■■ : v■i■■ii■1!■■ ■■■■� �I ■ ■■■•■■■■■slur■■■! ■■■ ■i ■■■■■ ■i 1 01111I■■hU■II iL PROJECT: SHEET NO. T Y T ISSUED FOR PERMIT REVISION 03.13 08 ISSUED FOR PERMIT REVISION 03.13.08 CONSOLIDATION SET 02.20.08 ISSUED FOR CONSTRUCTION 01.17.08 ISSUED FOR OWNER'S REVIEW 01.07.08 ISSUED FOR PERMIT NO. DESCRIPTION MECHANICAL DETAILS SHEET 2 OF 2 12.20.07 DATE 1NTERNAP° 3355 South 120th Place Tukwila, WA 98168 PROJECT NO. 2007 -536 DATE 12/20/07 DRAWN BY STAFF CHECKED BY CMA SCALE AS NOTED SHEET TITLE PHASE 11