HomeMy WebLinkAboutPermit M07-290 - SABEY CORPORATIONSABEY CORPORATION 3355 S 120 PL M07 -290 Parcel No.: 1023049069 Address: Suite No: Tenant: Name: Address: 3355 S 120 PL TUKW SABEY CORPORATION 3355 S 120 PL , TUKWILA WA Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: TONY MARINO Address: 5005 3RD AVE S , SEATTLE WA Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA Contractor License No: MCKINCL942DW DESCRIPTION OF WORK: INSTALL EXHAUST DUCTWORK FROM EMERGENCY GENERATOR TO ROOF. PROVIDE 4 EXHAUST FANS. PROVIDE NEW FUEL OIL PIPING FROM EXISTING CONNECTION POINT TO DAY TANK THAT WILL ALSO BE PROVIDED. PROVIDE FUEL OIL PIPING FROM DAY TANK TO GENERATOR. ALL FUEL OIL PUMPS WILL ALSO BE PROVIDED. Value of Mechanical: 277,000.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC -10/06 City'itif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY * *continued on next page ** Permit Number: M07 -290 Issue Date: 01/28/2008 Permit Expires On: 07/26/2008 Phone: Phone: 206 - 832 -8462 Phone: (206)762 -23311 Expiration Date: 03/16/2008 Fees Collected: $2,561.79 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -290 Printed: 01 -28 -2008 Permit Center Authorized Signature: Signatur City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -290 Issue Date: 01/28/2008 Permit Expires On: 07/26/2008 Date: 011 n Cal I hereby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied th, hether specified herein or not. The granting of this permit does not presuYne to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the • • rmance of work. I am authorized to sign and obtain this mechanical permit. Date: Print Name: / /T Je e i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M07 -290 Printed: 01 -28 -2008 Parcel No.: 1023049069 Address: Suite No: Tenant: 3355 S 120 PL TUKW SABEY CORPORATION 1: ** *BUILDING DEPARTMENT CONDITIONS * ** �lri �.iC City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: MOT -290 ISSUED 12/26/2007 01/28/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 13: Maintain fire extinguisher coverage throughout. 14: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so doc: Cond -10/06 M07 -290 Printed: 01 -28 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and International Building Code. 19: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 20: Sprinkler design shall be a minimum Ordinary Hazard Group II with a minimum design area of 3,000 square feet.(IFC Sect. 2704.6 {2006 Edition }) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 22: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 23: Material safety data sheets for all hazardous materials on the premise shall be readily available on site for emergency personnel. (IFC 2703.4) 24: Visible hazard identification signs shall be placed at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit. Individual containers, cartons or packages shall be conspicuously marked or labeled in accordance with nationally recognized standards. (IFC 2703.5) (NFPA 704)) 25: "No Smoking" signs shall be conspicuously posted within and at all entrances to hazardous materials storage areas. (IF'C 2703.7.1(1 -4)) 26: Above ground flammable liquid tanks shall be U.L listed and comply with NFPA 30. Tank installation shall comply with Sections 2704,2705, and 3404 of the International Fire Code(2006 edition) 27: Spill containment systems or means to render a spill harmless to people or property shall be provided where a spill is determined to be a plausible event and where such an event would endanger people or property. (IFC 2701.3.3.4) 28: Fuel oil piping shall be installed in compliance with Chapter 13 of the International Mechanical Code and tested in compliance with NFPA 31, Section 8.9. 29: Due to quantity of fuel oil exceeding maximum allowable quantities, generator room needs to meet rquirements of an H -3 occupancy.(IFC Table 2703.1.1) 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 31: To schedule all construction fire - related inspections send an e-mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. doc: Cond -10/06 M07 -290 Printed: 01 -28 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 32: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 33: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila (206)575 -4407. * *continued on next page ** doc: Cond - 10/06 M07 - 290 does not imply approval of Fire Prevention Bureau at Printed: 01 -28 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: /l� �✓ l�/P f'/ Date: doc: Cond -10/06 M07 -290 Printed: 01 -28 -2008 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htqx//www.ci.tukwila.wa.us SITE LOCATION Site Address: 6355 S / 20 "ter Tick nrt lo' h1I3 Tenant Name: 5a bey CQ //9oraJ) C \ Property Owners Name: !! 5a/X Mailing Address: 3355 5. /ZOO ?/C- CONTACT PERSON - who do we contact when your permit is ready to be issued Name: 7:0/7y ///ot ri W / ck Z'i5 'Y 4Q • Day Telephon«C2ao \ S3 2 - 8 6 2 - ) Mailing Address: 5601 3I'd /'✓P, s . t!O �g/ 3 i City State Zip Fax Number: (206 S 3i - $(n (ci 2- E -Mail Address: fon y 177 e fi C k nsivy . cam GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: l y COrp# 'Jio, Mailing Address: 270 T f/1f?'rnRheneza Contact Person: /IArCP /O ( el 'Cc" S E -Mail Address: P Y i / A p ' C e ' / 0 ✓ q Z SCi 1 ( j . CO m Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by, Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Meitins Mailing Address: SD 0 5 Contact Person: / iVa /' it2y' E -Mail Address: Q:Wpplications\Porms- Applications On Revised: 9 -2006 bit Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 2006 - Permit Application.doc C 0 . 3rd /,vr . // I 14. Public Works Permit No. Project No. (For office use only) Building Permit No. Mechanical Permit No. '4( - ) Plumbing/Gas Permit -No. King Co Assessor's Tax No.: /04:2 3o `/ fay' q Suite Number: 520/ Floor: New Tenant: ❑ Yes b K.No Tvx w. / City w / T State 90 /ro Zip /3/ ✓0 4/ F /oav Sea- wf3. 9 $ 1 4:4 City State /Zip 512 Day Telephone: 2 — 321 4 Fax Number: ZO(, — 243 I — Q92C' Expiration Date: State Zip City Day Telephone: Fax Number: City ' State Zip Day Telephone:( ) 03 2-- 94(0 a Fax Number.2 /Z ) Fi,3 Z - e362l„ Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty ' Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator – Comm/Ind MECHANICAL PERMIT INFORMATION 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION _Company Name: / �—,/ C .� f ,+ t � I nSfry Mailing Address: CO" #k 1„ `��1i3�1 City /' `e Zip Contact Person: ! f>/l V ino Day Telephone: C: z / t 32^ gqG2 E -Mail Address: 10/1V ( /t'/@ An /f?(iZs fl cao Fax Number: G Z6 )) q12- $ ' Z Contractor Registration Number: /' 1 E' 1/N L 7L( )(4) Expiration Date: 3/I&/2 00 8 Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please provide deta ed information): H7 Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ... Replacement .... ❑ Indicate type of mechanical work being installed and the quantity below: Q: Applications \Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh IsvOrk - ett 7 r* 1 &p_8 e Fuel Type: Electric ❑ Gas ....0 Other: Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Fir al Va T nkS 2 Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: / - 1[. h Ipl5 i Mailing Address: J 2 UC S Contact Person: 1y )r,r4D E - Mail Address: f D Cie/04' /'t t1?SF/ . Cp/+s Contractor Registration Number: MEKIIJGL gitol AA.} Q: Wpplications\Forms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Seit grr tate Zip City Day Telephone: 004 $32.-- & f6 Fax Number:. (a: ) e.??- aa Expiration Date: 3 14,17...008 -- � . I n • . MIM ,0•7/..1 141/ 0 S,6 Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Sewer: Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center -to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days.following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section. 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: Print Name: in writing and justifiable cause'demonstrated. Sectionl 01 :4.3 Uniform Plumbing Code (current edition). BUILDING OWNER .0 Mailing Address: / Date Application Accepted: I.)--.)-Co -07 Date Application Expires: to -( -0 Staff Initials: , ,n i Q:\Applications\Forms - Applications On Line\3 -2006 - Permit Application.doc Revised: 9 - 2006 bh Sgfirize City Date: 47 — a -O L� f Cep Day Telephone: Sz j State Zip Page 6 of 6 Receipt No.: R08 -00235 Payee: MCKINSTRY ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 1023049069 Permit Number: M07 -290 Address: 3355 S 120 PL TUKW Status: APPROVED Suite No: Applied Date: 12/26/2007 Applicant: SABEY CORPORATION Issue Date: Initials: JEM Payment Date: 01/28/2008 09:08 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 273200 2,202.82 MECHANICAL - NONRES 000/322.100 PLAN CHECK - NONRES 000/345.830 Account Code Current Pmts Payment Amount: $2,202.82 2,055.43 147.39 Total: $2,202.82 7724 01/28 9710 TOTAL 2202.82 doc: Receiot -06 Printed: 01 -28 -2008 Parcel No.: 1023049069 Address: 3355 S 120 PL TUICW Suite No: Applicant: SABEY CORPORATION Payee: MCBINSTRY CO TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Receipt No.: R07 -02854 Payment Amount: $358.97 Initials: WER Payment Date: 12/26/2007 10:11 AM User ID: 1655 Balance: $1,465.88 Amount Payment Check 9277 358.97 Account Code Current Pmts 000/345.830 358.97 Total: $358.97 Permit Number: M07 -290 Status: PENDING Applied Date: 12/26/2007 Issue Date: 6481 12/26 9710 TOTAL 358.97 doc: Receiot -06 Printed: 12 -26 -2007 Project: 5 +3 (-,-) pit 4- -,\ T of Inspecti n: lute � . t &j Address: r p c., Date Called: Special Instructions: Date Wanted: J Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: P { 'Inspector: O ` (Date: 0 Z L V y ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Projec Type of Inspection; n Address: Vi+ "?.3.5 10 /Iv �., Date Called: fl_..).... / --- - f--s- Special Instructions: Date Wanted: S : (c 'i) f ` a. p.m. Requester: Phone No: �_�� SO4, USC( — mil Z,&3 Mo'7.2 go INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 • ve COMMENTS: (Date: 0/2 Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: � / '�( , Type of I nspect I ion: 1 L. . /� ` \ Tr-_,, 1,4 f . ok �J (.e , : t'.. -o! / -e--c:7 ) t. or -!� S `' -.IAt c !, r ti <.— •S ; ,1..1 fyi - f'- -- 0 ; i "a.m. r‘ ,s n--r 7 / e 4 , r Project: ).A4-›-e2/ � / � � / '�( , Type of I nspect I ion: 1 L. . /� ` \ Tr-_,, 1,4 f . Address: 33 sS S, (t /20 '� Date Called: ti �- Special Instructions: Date Wanted: "a.m. Requester: Phone No: 44( INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3q7 0 Approved per applicable codes. Ei orrect ions required prior to approval. l inspec or: ' / \ 1Date:7 d ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: )or1. - 11v PERMIT NO. 06 -05 -2008 TONY MARINO 5005 3RD AVE S SEATTLE WA 98134 RE: Permit No. M07 -290 3355 S 120 PL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/26/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, Je if r Marshall Permit Technician xc: Permit File No. M07 -290 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 December 27, 2007 Tony Marino 5005 3` Ave S Seattle WA 98134 RE: Letter of Incomplete Application # 1 Development Permit Application M07 -290 Sabey Corporation — 3355 S 120 P1 Dear Mr. Marino, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on December 26, 2007 is determined to be incomplete. Before your application can continue the plan review process the attached items from the following department needs to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted throuch the mail or by a messen'er service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician Enclosures File: M07 -290 City of Tukwila Department of Community Development Steve Lancaster, Director ROE4QJ- P:\Permit Centerllncomplete Letters\2007\M07 -290 Incomplete Ltr #1.DOC vier Steven M Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Determination of Completeness Memo Date: . December 27, 2007 Project Name: Sabey Corporation Permit #: M07 -290 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Mechanical and energy codes reference outdated codes. Please revise code notes and review plan design including energy code references to show compliance with the current 2006 International Mechanical codes and 2006 Washington State Energy codes with Washington State Amendments. Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. DEPARTMENTS: Bui g P I sion Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 e PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -290 DATE: 01 -03 -08 PROJECT NAME: SABEY CORPORATION SITE ADDRESS: 3355 S 120 PL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Permit Coordinator DUE DATE: 01 -08-08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DATE: Planning Division n C n DUE DATE: 02 -05-08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: `PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -290 DATE: 12 -26 -07 PROJECT NAME: SABEY CORPORATION SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Xi Public Works ❑ Structural ❑ Permit Coordinator 6I2 AA 12 ' ' Fire Prevention X Planning Division DETERMINATION OF COMPLETENESS: (Tues., Thu s.) DUE DATE: 'I 2 -27 -07 Complete ❑ Incomplete Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: I) ")- `D7 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg er Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) C Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 DUE DATE: 01 -24 -08 Date: , 13 � 0F City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M07 -290 • Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Sabey Corporation Project Address: 3355 S 120 PI Contact Person: Tony Marino Phone Number: 206` Z32' $y62 Summary of Revision: 0/17.2.4 / OLit ✓.it /eTCn iio J 2(22(1 Lcie d a it / /1/e s � � y� fi Sheet Number(s): /162 "Cloud" or highlight all areas of revision including date of r: ision Received at the City of Tukwila Permit Center by, Entered in Permits Plus on I I \applications\forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director ofi rr0kwit.4 JAN - 3 2 008 ~EyMi7 4ENTE6 License Information License MCKINCL942DW Licensee Name MCKINSTRY CO LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602569922 Ind. Ins. Account Id 70616500 Business Type LIMITED LIABILITY COMPANY Address 1 PO BOX 24567 Address 2 City SEATTLE County KING State WA Zip 98134 Phone 2067623311 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/16/2006 Expiration Date 3/16/2008 Suspend Date Separation Date Parent Company Previous License MCKIN * *372N0 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PEDERSEN, JAMIE D AGENT 03/16/2006 ALLEN, DEAN C PARTNER/MEMBER 03/16/2006 MOORE, DOUGLAS J PARTNER/MEMBER 03/16/2006 ALLEN, DAVID E PARTNER/MEMBER 03/16/2006 TEPLICKY, JOSEPH PARTNER/MEMBER 03/16/2006 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MCKINCL942DW 01/28/2008 F625-052-000 (8/97) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL 3/16/2006 IS .. , INCI942DW • EFFECTIVE DATE MCKINSTRY CO LLC :PO BOX 24567 SEATTLE WA 98134 I certify this to be a true copy of the original Dated this 22nd day of May 2006. W C� Notary Public in and for the State of Washington Residing in Kent My commission expires 4 -19 -07 SHEET NUMBER SHEET TITLE MO.0 DRAWING INDEX, SYMBOLS AND ABBREVIATIONS MO.1 SEISMIC INFORMATION M2.1 HVAC 1ST FLOOR PLAN P2.1 PLUMBING 1ST AND 2ND FLOOR PLAN P6.0 PLUMBING DIAGRAMS P7.0 SCHEDULES - PLUMBING ABBREVIATIONS GENERAL AD ADJ AFF AFG AG AMP ARCH AUTO AUX BD BHP BLDG BOP BOT Bs BTU BTUH CA CAB COND C/L CLG CFM CLG CO CO2 COL CONC COND CONN CONSTR CONTR CTL DET DIA DLAG DIM DISCH DIV DN DS DWDI DWG DWV (E) EA EC EL ELEC ELEV EP EQUIP ESP EXH EXIST (F) F FA FCO FDC FDN FIG FIN no FLEX FLG FLR FO FP FPM Fr FTG FURN GA GALV GC GEN GPM GWB HP HR HS HTG HTR ID LAB LF MAU MAX MBH MED MEZZ MFR MH MIN MISC MTD N/A NC NEG NIC NO NOM NTS OA OC OD OVHD SECT SF SIM SPEC SQ STD STRUC ACCESS DOOR ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE GROUND AMPERE ARCHITECT; ARCHITECTURAL AUTOMATIC AUXILIARY BOARD BRAKE HORSEPOWER BUILDING BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR COMPRESSED AIR CABINET CONDENSATE CENTER LINE CEILING CUBIC FEET PER MINUTE CEILING CARBON MONOXIDE CARBON DIOXIDE COLUMN CONCRETE CONDENSER; CONDENSATE CONNECT; CONNECTION CONSTRUCTION CONTRACTOR CONTROL QTY QUANTITY DETAIL DIAMETER DIAGONAL DIMENSION DISCHARGE DMSION DOWN DISCONNECT SWITCH; DOOR SWITCH DOUBLE WIDTH, DOUBLE INLET DRAWING DRAIN, WASTE, VENT EXISTING EACH ELECTRICAL CONTACTOR; END CAP ELEVATION ELECTRICAL ELEVATION ELECTRICAL PANEL; END PLUG EQUIPMENT EXTERNAL STATIC PRESSURE EXHAUST EXISTING FUTURE FAHRENHEIT A RE ALARM FLOOR CLEANOUT FIRE DEPARTMENT CONNECTION FOUNDATION FIGURE FINISH FURNISHED AND INSTALLED BY OWNER FLEXIBLE FLANGE FLOOR FUEL OIL FIRE PROTECTION FEET PER MINUTE FOOT; FEET FOOTING FURNISH GAGE GALVANIZED GENERAL CONTRACTOR GENERATOR GALLONS PER MINUTE GYPSUM WALL BOARD HIGH HORSEPOWER; HIGH PRESSURE HEATING RETURN HEATING SUPPLY HEATING HEATER. INSIDE DIAMETER /DIMENSION LABORATORY LINEAL FOOT MAKE -UP AIR UNIT MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MEDIUM MEZZANINE MANUFACTURER MANHOLE MINIMUM; MINUTE(S) MISCELLANEOUS MOUNTED NOT APPLICABLE NORMALLY CLOSED NEGATIVE NOT IN CONTRACT NORMALLY OPEN; NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OVERHEAD POC POINT OF CONNECTION PRELIM PRELIMINARY PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE R RELOCATED RAD RADIUS REQD REQUIRED RPM REVOLUTIONS PER MINUTE SECTION SQUARE FOOT SIMILAR SPECIFICATION SQUARE STANDARD STRUCTURAL TBD TI TOC TOS TYP UG UNDERGROUND UNO UNLESS NOTED OTHERWISE VAV VD VER VFD VSD W/ WITH W/O WITHOUT HVAC AC ACT AHU BDD BOO CC CRU CT CV DB DIFF DMPR EA EAT ECG EF FCU FD FM FP FTU HC HR HVAC TO BE DETERMINED TENANT IMPROVEMENTS TOP OF CONCRETE TOP OF STEEL TYPICAL VARIABLE AIR VOLUME VOLUME DAMPER VERIFY VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE AIR CONDITIONING ACOUSTICAL CEILING TILE AIR HANDLING UNIT BACKDRAFT DAMPER BOTTOM OF DUCT COOLING COIL COMPUTER ROOM UNIT COOLING TOWER CONSTANT VOLUME DRY BULB DIFFUSER DAMPER GRD GRILLE, REGISTER, DIFFUSER LAT LEAVING AIR TEMPERATURE LD LINEAR DIFFUSER MC MECH MOD MUA OA OVERALL; OUTSIDE AIR OBD OPPOSED BLADE DAMPER RA RAT RCP RTU SA SAT SD SF S /FD SL SLSM SM SP TOFI TG TOD TSP UH WB WC WG TOTAL DYNAMIC HEAD TRANSFER GRILLE TOP OF DUCT TOTAL STATIC PRESSURE UNIT HEATER WET BULB WATER COLUMN WATER GAUGE PLUMBING AD AREA DRAIN CO DCW DHW DHWC DSP EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE EXHAUST FAN FAN COIL UNIT FIRE DAMPER FREQUENCY MODULATION FIRE PROTECTION; FAN POWERED FAN TERMINAL UNIT HEATING COIL HEATING RETURN HEATING, VENTILATION AND AIR CONDMONING MECHANICAL CONTRACTOR MECHANICAL MOTOR OPERATED DAMPER; MODULATING MAKE UP AIR RETURN AIR RETURN AIR TEMPERATURE REFLECTED CEILING PLAN ROOF TOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE SMOKE DAMPER SUPPLY FAN SMOKE FIRE DAMPER SOUND LINED SOUND LINED SHEET METAL SHEET METAL STATIC PRESSURE CLEAN OUT; CARBON MONOXIDE DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRCULATION DRY STANDPIPE EWC ELECTRICAL WATER COOLER FD FLOOR DRAIN IE INVERT ELEVATION IN WC INCHES WATER COLUMN IW IONIZED WATER; INDIRECT WASTE NPCW NON POTABLE COLD WATER ORL OVERFLOW RAINWATER LEADER PD PERF PLBG PRV PLANTER DRAIN; PRESSURE DROP PERFORATED PLUMBING PRESSURE REDUCING VALVE RPBP REDUCED PRESSURE BACKFLOW PREVENTER SD STORM DRAIN SS SANITARY SEWER VTR WC WH WSP CD CHW CHR CHS CT VENT THROUGH ROOF WASTE WATER CLOSET WATER HEATER WET STANDPIPE PIPING BP BACKFLOW PREVENTER CONDENSATE DRAIN CHILLED WATER CHILLED WATER RETURN CHILLED WATER SUPPLY CONICAL TEE EWT ENTERING WATER TEMPERATURE FHV FIRE HOSE VALVE LWT LEAVING WATER TEMPERATURE TOP TOP OF PIPE PIPING IDENTIFICATION FIVAC PLUMBING A COND - CDR - CDS CHS - CHR - 0 HR HS RL - --- RS ST GRW GAW ID IRR NP ORL rW PSD RWL SD -- SS - --- UD - W FIRE PROTECTION DSP FDC F PIPING FITTINGS lc. 1t1 1I 101 VALVES FP FW WSP 4 uv 1,AV 4 ""V Q Y I�I PIPING ACCESSORIES RPBP 0 D I IT . ❑4 -# # WATTS /LF A COND CDR CDS CHS CHR G HR HS RL RS ST CW GRW GAW HW HWC ID IRR NPCW ORL PW PSD RWL RWL SD SS UD V W W DSP FDC FP FW WSP COMPRESSED AIR PIPE CONDENSATE DRAIN PIPE CONDENSER WATER RETURN PIPE CONDENSER WATER SUPPLY PIPE CHILLED WATER SUPPLY PIPE CHILLED WATER RETURN PIPE NATURAL GAS PIPE HEATING WATER RETURN PIPE HEATING WATER SUPPLY PIPE REFRIGERANT LIQUID PIPE REFRIGERANT SUCTION PIPE STEAM SUPPLY COLD WATER PIPE (POTABLE) GREASE WASTE GARAGE WASTE HOT WATER PIPE (POTABLE) HOT WATER CIRCULATING (POTABLE) INDIRECT DRAIN IRRIGATION WATER PIPE NON- POTABLE CW PIPE OVERFLOW RAINWATER LEADER PUMPED WASTE PUMPED STORM DRAIN RAINWATER LEADER BELOW GRADE RAINWATER LEADER STORM DRAIN PIPE SANITARY SEWER PIPE (SITE) UNDERDRAIN PIPE VENT PIPE (SANITARY) WASTE PIPE WASTE PIPE BELOW GROUND DRY STAND PIPE FIRE DEPT. CONNECTION PIPE FIRE SPRINKLER PIPE FIRE PROTECTION WATER PIPE FIRE PROTECTION WASTE PIPE WET STAND PIPE TEE W /PIPE UP TEE DOWN W /ELBOW TEE UP W/ ELBOW TEE UP TEE DOWN 90' ELBOW UP g0' ELBOW DN CAP UNION FLANGE FLEX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW CONCENTRIC REDUCER ECCENTRIC REDUCER SLOPE SYMBOL - BREAK OR CONTNUATION SYMBOL DOWN SPOUT NOZZLE CLEANOUT 45' ELBOW 45' ELBOW 90' ELBOW 90' ELBOW CROSS TEE WYE TAP HOSE CONNECTION MOTORIZED 2 -WAY VALVE MOTORIZED 3 -WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALL VALVE 3 -WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VAVLE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3-WAY GATE PLUG VALVE BALANCING VALVE HOSE BIBB PUMP MANUAL AIR VENT AUTOMATIC AIR VENT HIGH CAPACITY AIR VENT SHOCK ARRESTOR FLOW SWITCH VACUUM BREAKER PRESSURE GAUGE TEMPERATURE SENSOR TEMPERATURE INDICATOR AUTO FLOW VALVE FLOW METER Y STRAINER Y STRAINER W/ BALL VALVE PIPE SLEEVE STEAM TRAP PETES PLUG HEAT TRACING SUCTION DIFFUSER W/ STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR FUNNEL DRAIN FLOOR DRAIN ROOF DRAIN ROOF OVERFLOW DRAIN FLOOR SINK DUCTWORK ACCESSORIES IF � i=T=t { r AD � L J AD 12x12 SL 12x12 2 - DUCTWORK RECTANGULAR DUCT RECTANGULAR DUCT r , I X L. " RECTANGULAR DUCT RECTANGULAR DUCT ElaD I I I BIRDSCREEN OR SCREENED OPENING SUPPLY GRILLE RETURN OR EXHAUST GRILLE VOLUME DAMPER MOTOR OPERATED DAMPER AIRFLOW MONITOR REMOTELY OPERATED VOLUME DAMPER (YOUNG REGULATOR OR APPROVED) BACK DRAFT DAMPER COORDINATE WITH CEILING APPURTENANCES_ FLEX CONNECTION FIRE DAMPER THROUGH WALL FIRE DAMPER THROUGH FLOOR FIRE /SMOKE DAMPER THROUGH WALL FIRE /SMOKE DAMPER THROUGH FLOOR ACCESS DOORS 1' ACOUSTICALLY LINED DUCT 2' ACOUSTICALLY LINED DUCT CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES SMOKE DETECTOR C�> THERMOSTAT SENSOR RETURN / EXHAUST / OUTSIDE AIR SUPPLY / TRANSFER AIR TERMINAL UNITS - SEE SCHEDULE FOR TYPE SUPPLY AIR DUCT TURNING UP OR TOWARD SUPPLY AIR DUCT TURNING DOWN OR AWAY EXHAUST OR RETURN AIR DUCT TURNING UP OR TOWARD EXHAUST OR RETURN AIR DUCT TURNING DOWN OR AWAY ROUND DUCT TURNING UP OR TOWARD ROUND DUCT TURNING DOWN OR AWAY OVAL DUCT TURNING UP OR TOWARD OVAL DUCT TURNING DOWN OR AWAY FLEXIBLE DUCT INSTRUMENTATION AND CONTROLS CARBON MONOXIDE SENSOR VISUAL ALARM LIGHT - WALL MOUNTED TL �4 GRILLE/REGISTER /DIFFUSER DOUBLE LINE 4- x t X I S- C8 -09 -A 000 000 ▪ CEILING SUPPLY AIR DIFFUSER HVAC - ANNOTATION VAV BOX TAG 1 -23 S- C8 -09- -A 1 1 • DUCTWORK EQUIPMENT TAG CEILING RETURN, EXHAUST OR TRANSFER AIR GRILLE LINEAR DIFFUSER (CEILING) LINEAR DIFFUSER (WALL) LOUVER PLAN VIEW LOUVER (ELEVATION VIEW) 95 ROUND DUCT SYMBOL -8- FLAT OVAL DUCT SYMBOL IEF -2 -1I — CONSECUTIVE EQUIP. II FLOOR OF EQUIP_ LOCATION EQUIPMENT DESIGNATION GRILLE, REGISTER, OR DIFFUSER TAG DT5 -618 CFM EACH SIZE TYPE CODE LOUVER TAG LEGAL DESCRIPTION LOCATION / SITE MAP CEILING SUPPLY AIR DIFFUSER (SHOWN WITH THROW ARROWS) I CONSECUTIVE LOUVER it_ FLOOR LOCATED FLOOR # - DISCRETE BOX # SEE BELOW PRIMARY CFM FAN CFM ACOUSTICAL ACCESSORIES (IF REQ'D) KW OF AUX. HEAT. VAV BOX SIZE; SEE SCHED_ SERIES FAN POWERED BOX (5) PARALLEL FAN POWERED BO (P) EQUIPMENT TAG 1-1)513 CFM DIFFUSER GRILLE 1 CFM EACH I ACTIVE LENGTH IN FT. TOTAL LENGTH IN FT. TYPE CODE LOUVER TAG FACADE DESIGNATION B - BANK M - MUSEUM NE 1/4 OF THE SE 1/4 AND SE 1/4 OF THE SE 1/4 OF SECTION 9 AND GOV'T LOT 15 AND SW 1/4 OF THE SW 1 /4 OF SECTION 10, T23N., R4E., W.M. CITY OF TUKWILA, KING COUNTY, WASHINGTON_ GENERAL INFORMATION SYMBOLS X X X X X X X X X X X X X X GENERAL NOTES: DRAWING INDEX NEW MECHANICAL WORK FUTURE TI SCOPE & NEW WORK OTHER THAN MECHANICAL DEMO MECHANICAL WORK DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN PLAN NUMBER SHEET NUMBER WHERE, PLAN SHOWN REVISION NUMBER - DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED REVISION CLOUD - DENOTES AREA OF CHANGE DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION MATCHLINE PLUMBING FIXTURE CALL -OUT (SEE PLUMBING SCHEDULES) DRAWING NOTE REFERENCE POINT OF CONNECTION CENTERLINE STRUCTURAL BEAM PENETRATION (SEE M503) STRUCTURAL BEAM HAUNCH (SEE M503) 1_ VERIFY LOCATIONS AND DIMENSIONS OF ALL EQUIPMENT AND COORDINATE. ALL WORK PRIOR TO START OF CONSTRUCTION_ 2. OBTAIN WRITTEN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF PENETRATIONS IF NOT SHOWN ON DRAWINGS_ 3. REFER TO CIVIL DRAWINGS FOR UTILITY WORK 5' -0 BEYOND THE BUILDING LINE. 4. CONCRETE EQUIPMENT CURBS, PIPING RAT SLABS, SUMP BASINS, AND , HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND WILL BE PROVIDED BY GENERAL CONTRACTOR. SEE STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. 5_ COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS A. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER PER 2006 WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416.2.4.3 B_ AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416 :2.4.2 C_ ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 1416.2.1 D_ HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS ,AND APPROVED PLANS PER WSEC SECTION 1416.2.3.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.2.4.2; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURE AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416.4.2.5.1 AND 1416.3.1; AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.52_ 6_ THE BUILDING MECHANICAL SYSTEM SHALL COMPLY OR EXCEED THE REQUIREMENTS AS SET FORTH IN THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1410 - GENERAL REQUIREMENTS_ 7_ THE MINIMUM REQUIREMENTS FOR VENTILATION SHALL COMPLY OR EXCEED THE 2006 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE_ 8_ ALL MOTORS PROVIDE BY THE MECHANICAL CONTRACTOR SHALL COMPLY WITH THE 2006 WASHINGTON STATE ENERGY CODE CHAPTER 15. 9_ INSULATE ALL SYSTEMS AS REQUIRED TO MEET THE 2006 WASHINGTON STATE ENERGY CODE CHAPTER 14, TABLE 14 -5. 10_ BEFORE MAKING CONNECTIONS TO EQUIPMENT FURNISHED BY THE OWNER OR OTHERS VERIFY THAT EXACT INFORMATION IS PROVIDED_ 11. REFER TO STRUCTURAL DRAWINGS FOR EQUIPMENT SUPPORTS. REFER TO SHEET M0.1 FOR ADDITIONAL SEISMIC INFORMATION. Fuel Oil Piping: Isolate and test existing fuel oil supply and return pipe for leaks. Replace all pipe that fails test with new as specified in pipe matrix. Replace all existing sensors and test existing probes. Provide new pipe from capped and valved end of existing to new emergency generator. Test contents of existing fuel oil storage tanks and dispose of all fluids properly. Install pumps (from building stores) in existing fuel storage tank and connect to existing double walled fuel oil pipe. Install new day tanks with pumps. Provide and install all sensors and probes. Day tank to be provided with float level controls to indicate low level fuel condition (alarmed), turn on pump at main tank, turn off the main storage tank pump, and to alarm a high fuel level situation in the day tank and turn on the return pump. Controls provided by day tank manufacturer. FILE COPY Permit No. Plan review approval Is slant to emu and Approval of constnalon documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Fwd Copy ands is aclmowledgect By. — P U e Date: City of Tukwila BUILDING DIVISION 6EPARATE PERMIT REQUIRED FOR: ❑ Mechanical ❑ ✓Electrical [ Plumbing I nrGas Piping City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 44008 QEI1MIT CENTER REVISIONS No changes shall be mane to the scope of Veo. - k with:,; i + 1 , )t - '; , i)p)1 . '.i1 r + ukw{Ia bu:111,1 i -, n11J;svon NOTE: Revisions will require and may include additional onal plan re ew fees. submittal REVIEWED CODE APPROVED 3!\ \ S of Tu QI4 a DIl YEN INCOMPLETE LTR# I ... 210 GENERATOR ROOM DESIGN DRAWINGS instr fe Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOK 24567 SEATTLE, WA 98124 1- 800 -669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503- 331 -0234 www.mckinstry.com PROJECT KING COUNTY DATA CENTER AT SABEY CORP TUK 5 BUILDING SBC 5201 3355 S. 120th Place Tukwila, WA 98168 REGISTRATION: I EXPIRES: 05 - 11 - 09 REVISIONS: NO DATE 10/3/07 11/13/07 12/5/07 0 01/2/08 McKINSTRY DMSION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE SCALE: SHEET TITLE: DESCRIPTION SCHEMATIC HVAC DESIGN FOR REVIEW DESIGN DEVELOPMENT PERMIT SET REVISION 11 ENGINEERING T_ DIAZ B. HUCKINS M_ WEBB 35776 9 -28 -07 SEE DRAWING DRAWING INDEX, SYMBOLS, AND ABBREVIATIONS MECHANICAL, PIPING, AND PLUMBING IMPORTANCE FACTOR TABLE COMPONENT DESCRIPTION STANDARD COMPONENT IP =1.0 CRITICAL COMPONENT IP =1.5 NOTES: HVAC - SHEETMETAL/EQUIPMENT g Load g Load, with Exp. Anchors HVAC SUPPLY - MEDIUM PRESSURE X .61 g .55 g HVAC SUPPLY - LOW PRESSURE X .26 g .44 g HVAC OUTSIDE AIR X Level 1 Ceiling .23 g HVAC RETURN X .48 g Level 1 HVAC EXHAUST X .34 g .34 g TRANSFER AIR DUCT X GARAGE EXHAUST X GREASE KITCHEN EXHAUST DUCT (TYPE 1 HOOD EXHAUST) X NON - GREASE KITCHEN EXHAUST DUCT (TYPE 2 HOOD EXHAUST) X FLUES - BOILERS, HW HEATERS X PIPING HEATING WATER X CONDENSER WATER X NATURAL GAS X MAKEUP WATER X REFRIGERANT X PLUMBING COLD WATER (POTABLE) X COLD WATER (NON - POTABLE) X HOT WATER (POTABLE) X HOT WATER RECIRC (POTABLE) X CONDENSATE INDIRECT WASTE X NATURAL GAS MEDIUM PRESSURE (2 -5 PSIG) X NATURAL GAS LOW PRESSURE ( <14' WC) X RAINWATER LEADER/ OVERFLOW RAINWATER LEADER X UNDERSLAB DRAINAGE X SANITARY VENT X SANITARY WASTE X Piping Systems - Limited deformability elements and attachments (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g Piping Systems - High deformability elements and attachments (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .26 g .61 g .39 g .91 g Level 2 Ceiling .23 g .44 g .34 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g General Mechanical Equipment - Pressure Vessels and skirts free standing (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .91 g 1.21 g 1.36 g 1.82 g Level 2 Ceiling .65 g 1.09 g .98 g 1.63 g Level 1 Ceiling .48 g .8 g .72 g 1.2 g Level 1 .3 g .5 g .45 g .76 g Piping Systems - Low deformability elements and attachments (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .61 g .61 g .91 g .91 g Level 2 Ceiling .44 g .44 g .65 g .65 g Level 1 Ceiling .32 g .32 g .48 g .48 g Level 1 .23 g .23 g .34 g .34 g General Mechanical Equipment - Boiler and furnaces, Other (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g HVAC Systems - Non - vibration Isolated, Mounted in -line with ductwork, Other (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g HVAC Systems - Vibration Isolated (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .91 g 1.21 g 1.36 g 1.82 g Level 2 Ceiling .65 g 1.09 g .98 g 1.63 g Level 1 Ceiling .48 g .8 g .72 g 1.2 g Level 1 .3 g .5 g .45 g .76 g General Mechanical Equipment - Boiler and furnaces, Other Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Level1 B B A A General Mechanical Equipment - Pressure Vessels on skirts and free standing Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL, SHL with Exp. Anchors Level 3 Ceiling / Roof AA* AA* AA* - NA - Level 2 Ceiling AA AA* AA* - NA - Level 1 Ceiling A AA* AA* AA* Levell B AA A r AA* Piping Systems - High deformability elements and attachments Level Component Ip =1.0 Component Ip =1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof B AA A AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Level1 B B A A Piping Systems - Low deformability elements and attachments Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling 1 Roof AA AA AA* AA* Level 2 Ceiling A A AA AA Level 1 Ceiling A A A A Levell B B A A Piping Systems - Limited deformability elements and attachments Level Component Ip =1.0 Component Ip =1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Level1 B B A A HVAC Systems - Vibration Isolated Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof AA* AA* AA* - NA - Level 2 Ceiling AA AA* AA* - NA - Level 1 Ceiling A AA* AA* AA* Levell B AA A AA* HVAC Systems - Non-vibration Isolated, Mounted in -line with ductwork, Other Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Level1 B A A A OR SEIS V IC BASIS OF DESIG \ BRACE ALL DUCTWORK AND PIPING PER SMACNA'S "SEISMIC RESTRAINT MANUAL" OR MASON INDUSTRIES "SEISMIC RESTRAINT MANUAL" IN ACCORDANCE WITH THE COMPONENT IMPORTANCE FACTOR AND THE SEISMIC HAZARD LEVEL (SHL) OR 'g' LOAD LISTED IN THE APPLICABLE TABLE. OBTAIN THE COMPONENT IMPORTANCE FACTOR FROM THE DUCT WORK OR PIPING MATRIX. SEISMIC RESTRAINTS MAY BE EXCLUDED WHEN Ip, = 1.0: • MECHANICAL AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D, E, AND F WHERE Ip - 1.0 AND FLEXIBLE CONNECTIONS BETWEEN THE COMPONENTS AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT ARE PROVIDED AND THAT ARE MOUNTED AT 4 FT (1.22M) OR LESS ABOVE A FLOOR LEVEL AND WEIGH 400 LB (1780 N) OR LESS. [ASCE 7 -02 SECTION 9.6.1 - EXCEPTION #5] • MECHANICAL AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D, E, AND F WEIGHING 20 LB (95 N) OR LESS WHERE Ip = 1.0 AND FLEXIBLE CONNECTIONS BETWEEN THE COMPONENTS AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT ARE PROVIDED, OR FOR DISTRIBUTION SYSTEMS WEIGHT 5 LB /FT (7N /M) OR LESS. [ASCE 7 -02 SECTION 9.6.1 - EXCEPTION #6] • SEISMIC RESTRAINTS ARE NOT REQUIRED FOR HVAC DUCTS WITH Ip - 1.0 IF EITHER OF THE FOLLOWING CONDITIONS ARE MET: A. HVAC DUCTS ARE SUSPENDED FROM HANGERS 12 IN. (305 MM) OR LESS IN LENGTH FROM THE TOP OF THE DUCT TO THE SUPPORTING STRUCTURE. THE HANGERS SHALL BE DETAILED TO AVOID SIGNIFICANT BENDING OF THE HANGERS AND THEIR ATTACHMENTS. B. HVAC DUCTS HAVE A CROSS- SECTIONAL AREA OF LESS THAN 6 FT (0.557M [ASCE 7 -02 SECTION 9.6.3.10] • DUCTILE PIPING IN SEISMIC DESIGN CATEGORIES D, E, OR F DESIGNATED AS HAVING AN Ip = 1.0 AND A NOMINAL PIPE SIZE OF 3 IN. (75 MM) OR LESS. [ASCE 7 -02 SECTION 9.6.3.11.D.3] SEISMIC RESTRAINTS MAY BE EXCLUDED WHEN 1 = 1.0 OR I. = 1.5: • EQUIPMENT ITEMS INSTALLED IN -LINE WITH THE DUCT SYSTEM (E.G. FANS, HEAT EXCHANGERS, AND HUMIDIFIERS) WEIGHING LESS THAN 75 LB (344 N) DO NOT NEED TO BE BRACED INDEPENDENT OF THE DUCT SYSTEM. [INTERPRETED FROM ASCE 7 -02 SECTION 9.6.3.10] UNBRACED PIPING ATTACHED TO IN -LINE EQUIPMENT SHALL BE PROVIDED WITH ADEQUATE FLEXIBILITY TO ACCOMMODATE DIFFERENTIAL DISPLACEMENTS. [ASCE 7 -02 SECTION 9.6.3.10] • PIPING - ROD HANGERS SHALL NOT BE USED AS SEISMIC SUPPORTS UNLESS THE LENGTH OF THE HANGER FROM THE SUPPORTING STRUCTURE IS 12 IN. (305 MM) OR LESS. ROD HANGERS SHALL NOT BE CONSTRUCTED IN A MANNER THAT SUBJECTS THE ROD TO BENDING MOMENTS. [ASCE 7 -02 SECTION 9.6.3.11.4.C] S V AC \A SEJSV IC HAZARD LEVEL DESIG\ • SEISMIC DESIGN VALUES ARE CALCULATED IN ACCORDANCE WITH IBC 2003. IBC FORCES ARE "STRENGTH DESIGN" BASED. VALUES HAVE BEEN USED TO SELECT FROM SMACNA ADDENDUM NO. 1 TABLE AA -10 "NEW" VALUES IN ORDER TO USE THE SMACNA SEISMIC RETRAINT MANUAL. VALUES: * 1/2 Brace Spacing Required * 1/2 Brace Spacing Required HVAC/SHEETV ETAL/EQUIPV E\T SHL DESIG\ VALUES * 1/2 Brace Spacing Required * 1/2 Brace Spacing Required PIPI\ SHL * 1/2 Brace Spacing Required Highly Deformable Pipe Includes: Steel or Copper Piping with weld/braze /groove fitted joints. * 1/2 Brace Spacing Required Limited Deformable Pipe Includes: PVC or PVDF Piping G A \J DESIG\ PLUVB\G VALUES: * 1/2 Brace Spacing Required Low Deformability Piping Includes: Cast Iron, Glass Pipe, FRP (Fiberglass Reinforced Pipe) SETS V IC ALLOWABLE STRESS DESIG\ VALUES: • SEISMIC DESIGN VALUES ARE CALCULATED IN ACCORDANCE WITH IBC 2003. IBC FORCES ARE "STRENGTH DESIGN" BASED. VALUES HAVE BEEN CONVERTED TO "ALLOWABLE STRESS DESIGN" VALUES IN ORDER TO UTILIZE MASON INDUSTRIES SEISMIC RESTRAINT GUIDELINES. THESE VALUES CAN BE USED TO SELECT SEISMIC BRACING FROM MASON INDUSTRIES SEISMIC RESTRAINT GUIDELINES. HVAC /SHEETV ETAL/EQUH SEISVC 'g' LOAD: V E \T PIPI \G SEIS Highly Deformable Pipe Includes: Steel or Copper Piping with weld/braze /groove fitted joints. Limited Deformable Pipe Includes: PVC or PVDF Piping J PLUV1R\ 'g' LOAD G Low Deformability Piping Includes: Cast Iron, Glass Pipe, FRP (Fiberglass Reinforced Pipe) Mod - 290 I REVIEWED FOR 1 CODE COMPLIANCE APPROVED i/'N 1. 11 2008 GENERATOR ROOK DESIGN DRAWINGS City Of Tukwila +� B . ILDING DMSIDN instry le Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503- 331 -0234 www.mckinstry.com KING COUNTY DATA CENTER AT SABEY CORP TUK 5 BUILDING SBC 5201 3355 S. 120th Place Tukwila, WA 98168 REGISTRATION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET NUMBER: I EXPIRES: 05-11-09 REVISIONS: NO DATE DESCRIPTION 10/3/07 SCHEMATIC HVAC DESIGN FOR REVIEW 11/13/07 DESIGN DEVELOPMENT 12/5/07 PERMIT SET McKINSTRY DMSION: ENGINEERING T. DIAZ B. HUCKINS M. WEBB 35776 9 -28 -07 SEE DRAWING SHEET TITLE: SEISMIC INFORMATION M0.1 RECEIVED DEC 2 6 2007 PERMIT CEN 1 F4: GENERATOR FAN SCHEDULE TAG # EF -1 EF -2 EF -3 EF-4 BASIS OF DESIGN MANUF. GREENHECK GREENHECK GREENHECK GREENHECK MODEL S2- 30- 615 -B15 S2- 30- 620 -B20 S2 -30- 620 -B20 52- 30- 620 -B20 SERVICE GENERATOR EXHAUST GENERATOR EXHAUST GENERATOR EXHAUST GENERATOR EXHAUST FAN TYPE PROPELLER PROPELLER PROPELLER PROPELLER MOUNTING SIDEWALL SIDEWALL SIDEWALL SIDEWALL CFM @ 70F 10,800 10,800 10,800 10,800 E.S.P. .25" .25" .25" .25" BHP /HP 1.72/1.5 1.72/1.5 1.72/1.5 1.72/1.5 VOLTAGE/PHASE 460/3 460/3 460/3 460/3 MOTOR EFFICIENCY CODE MIN. CODE MIN. CODE MIN. CODE MIN. OVERALL WIDTH 22 22 22 22 OVERALL LENGTH 38 38 38 38 TOTAL WEIGHT (LBS) 130 130 130 130 SOUND CELLS (120 SF MIN.)I, •"1 ND SCREEN SEE NOTE #2 14" INLET, X 18" CUTLET, "Y' FITTING MUFFLER PROVIDED BY OTHERS. SEE, PLAN NOTE #1: L 18" STACK. TERMINATE WITH RAIN CAP. MATCH EXISTING MATERIALS. PROVIDE DRAIN SECTION AT - EXTERIOR ELBOW !} PROVIDE WALL SUPPORTS SPACED TO MATCH EXISTING. <; 4 NOTE: FOR FUEL OIL PIPING SEE PLUMBING DRAWINGS Note: Control with wall mounted thermostat. Fan on at 90' F., off at 80' F (adjustable). Fans EF -3 and EF -4 are future fans. JCILI SOUND CELLS AND SCREEN (288 SF MIN.) SEE NOTE #2 1 HVAC 1ST FLOOR GENERATOR ROOM 400 M2.1 SCALE : 1/8" 1' -0" F= FE �Ir PLAN NOTES: ® PROVIDE 14" PIPE FROM GENERATOR EXHAUST TO MUFFLER INLET AND ALL PIPE DOWNSTREAM OF MUFFLER OUTLET. HANG MUFFLER AND ALL PIPE FROM CEILING. INSULATE ALL PIPE AND MUFFLER IN GENERATOR ROOM. Q USE EXISTING SOUND CELLS FROM BUILDING STORES. IF ADDITIONAL SOUND CELLS ARE REQUIRED, PROVIDE DYNASONIC MODEL LBB (5 FT. LONG) 24" x24" OR 48"x24" TO PROVIDE REQUIRED AREA. REVIEWED FOR CODE COMPLIANCE APPROVE 10 1F? City Of iukvvil ILDING DI`IIS1Q BUILDING KEY PLAN NO SCALE t4O12c?O GE ERATOR R00 DESIGN DRAWINGS KING COUNTY DATA CENTER AT SABEY CORP TUK 5 BUILDING SBC 5201 3355 S. 120th Place Tukwila, WA 98168 REGISTRATION: REVISIONS: NO DATE DESCRIPTION 10/3/07 SCHEMATIC HVAC DESIGN FOR REVIEW 11/13/07 DESIGN DEVELOPMENT 12/5/07 PERMIT SET McKINSTRY DMSION: ENGINEERING DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE SHEET TITLE: HVAC 1ST FLOOR PLAN SHEET NUMBER: T. DIAZ B. HUCKINS M. WEBB 35776 9 -28 -07 SEE DRAWING instr le Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 M2,1 www.mckinstry.com I EXPIRES: 05 -11 -09 RECEIVED DEC 2 6 Z00 PERMIT CEN I I. F I 7 „ ' I -1 S 7- • 117 ‘--11-- r I FO ADDITIONAL FUEL OIL PlpING WORK IN THIS AREA SEE 2 P2.1 2 P2.1 SCALE: 1/8"=1'-0" AZ 4 FA-10 - ' 1 P 7 FAT 11'4 2■ Jd SA (f ' --M- 12L_Z - SL ThP '11 L • 6 21'.1 .18 SA 1 1 03 1311..... • I dr • 1 • FzI•1.1 FUTURE DAY TANKS 150:41 FLA HOD 13 • ir L6C1T, 10' -51" r EF'• 2 S 71 5. '2CF110 i ry.:F 14.6 71. KNA FOR ADDITIONAL INFORMATION SEE PIPING DIAGRAM, P6.0 1 IL: LI ENLARGED PLUMBING PLAN NIA,: P.: El ' BA1.2 SA. - ELM: '251, til 25.x' SA TY.1J . II J • '7 AL) - - ( 7" , I 1 -1/2" 1 ROE: -,-.." It..L:,' A1J LF1HAL"1 1 1 1 11.121.1 S 'J A05" . 1 FIA. "1.155' AFC " F1.....1. "15 '-'IHkkr GI , 1'...511. ,.1 P.3,1 Br' rAl MAN, . r.a,.: F Fe -1 . 7 • , 1RAI•4'51 ' 55,44 151 H4' 11 9,5 1 019E F EX A FAN = I HANSI 11C1 8 4" ,32 PRO.k..IDE F LEY Cr7.1F11^J.C 01 AT FAN \-GENERATORS (BY OWNER) cA:x44 F.; C 'LS1 1 .12* . oD 11 -Li" 1.• 1-1/2 & FOR ® 'X' 1 C.: G.; 21^ . SA Hir. • L 1A Z 22:3 C11..1 /4k1^ FRfl 146 , 1 16 7- 10,..0100# A3[ EI-6;• • - - 1S1 14 1.4 • ‘) I \ I I, • i121x5'.7 IA.A■ ' ' Cehr '2 tr.ismi.I.p111 , , - AFF -.. r THF J C 1 • 44A:131 I T ( I . 7 :IP . O r t1 LO UF ALA 4 -11" - Try c".14 „ .s m ',V:AdEN . -1:14' in: :Jai 41 I CF[A r • • 12F LI I • A Z A. V A I C; • ' 7 : i FUN • FA U.: L, V FL. '. 41- • . .PL '211"Fl F111 1-P1111 1 .14.1t1: A,L ALL PL.HE I. r I 1 H 1::rJAkt t.0 I [' - :'4"F/[A, FAD ' 1 1 5' '. "'"Ar F AA .• cH 1,4 P p A ' .r. FIFLA• ,e Fi FA F. -A LF x "Ar EXISTI SU PF H[i 2[ POC 1 P2.1 '411 • (3 ret [DELL: 0,1E' 'Jr, 74 F'A 1; TY ALT I 11 1 1. ^A^1 . I., •LFII 7 I 2,'RDSCR:E1 , HA I DPL1.111 FA CF +37 17711 17 , TlD1 2, • / . 7 .• ,LE. 44 I r2 .4 FF:l1.1 :: '11-ttPH4f. r_ E]ri Mom Ii nit L' CIIST01.1ER.. 1 7;0. 1 4 1 , • 2 .3E: F •r, 1 • H ,..94#.1 , Li. b. 03, 60,^3 13' PLAN NOTES: O EXISTING FUEL OIL TANK IS FILLED WITH WATER. TEST WATER QUALITY IN EXISTING FUEL TANK AND PROPERLY DISPOSE. C) ISOLATE AND TEST EXISTING DOUBLE WALLED PIPE BETWEEN TANK AND POC. ® INSTALL FUEL OIL PUMP FROM BUILDING STORED. CONNECT TO EXISTING FUEL OIL SUPPLY PIPE. CONNECT FUEL OIL RETURN PIPE TO TANK. 0 PROVIDE VALVED AND CAPPED 1-1/2" FUTURE CONNECTION. • • 12." .r Aft • • 5.1.t,.1 AlA 22 F. I 13FIF.1 71 •;.;" O REPLACE ALL SENSORS AND VERIFY THE CONDITION OF ALL PROBES. ® CONNECT NEW FUEL OIL SUPPLY AND RETURN PIPE TO EXISTING. O TWO FOS AND TWO FOR PIPES IN EXISTING TRENCH TO DAYTAN K. 6;1 FA E112') ' • S4AA RA F1' )F' 10= AC r7' 1 T '1 17, / PT(' VI FM' 2,1 21_ • • 1 SF 1 , _I FA, 52, :11 .4 1 ALL SC HIAL P 1' ,r1,_ r.A44FLP.3 ak ee tic .QE! I 2 1 ATI^ L;1^' CAC.11.1c.: [Ka, . 1 C I '" 84.01 FA 012E; 1 5' 64 I 2 F 4311 r.FIALI .51"x42 K1C. ' 3' • 3' el-t.F 11 A'1 , :•Ft.F1 ii• , P 1:5A ?F1(.2.'IDE THANE ELF:271 . .11 - 111 -1E,TER, 1 ..10LIEL ..11-:EL 7.1•V, YrA I. PReg 'AA, L IFFAIT ,TAT • cf; C3,31: 2:51E1 r.F'm I A AL 1- 1 Al') V. FP.,..AV a: .111.1 EXISTING FUEL 01 TO GE TANK 1 F I : OF 1.i • 1 .;,■ 7 NEW FUL OIL PUMP FOP-5201141 & 5201-B A. 215 1.1 - I 26 011121. Of F12 .:)1 I Kn ".IM 7 EXISTING 7 1.J EAU_ SUPPLY RETURN PIPES (3 ,,•6 IC Cr I 31 'TV PARTIAL COMPOSITE FIRST FLOOR PLUMBING PLAN ED SCALE: 1/16" = r-O" 2 '22 --i11•,=4 71 A3,I ,AAA 1 \71 ,--114 Ps; E3 12 4" , IA SpA 26.:17: • - L. AF',' 1111P11, GENERAL NOTES 1. ALL FUEL OIL PIPING LOW POINTS SHALL HAVE SUMP WITH LEAK DETECTOR. 2. COORDINATE ALL WORK WITH PRE-PURCHASED EMERGENCY GENERATOR. 3. DAY TANK SHALL BE INSTALLED BY CONTRACTOR FOR EACH GENERATOR. CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS INCLUDING VALVES, GAGES, FLEX CONNECTIONS AND FITTINGS AS INDICATED, SHOWN, OR REQUIRED. 4. ALL CONTROL AND POWER WIRING SHALL BE IN RIGID CONDUIT. rn2 ni •s4;` :N] FALL' 1tP.1,1 WALL A I :1 1 , • V rA V L t rt r Itr; -r 1, 11. ( V l 1-25 AREA OF WORK -; • EaqteFe 6 HO . 1 2 IF' INIERN41. 2, A.,f, Alt} ▪ 9nr. ILL r • LLS i,DEI 11' -0" • 34'LA 22: 50,2 - 2' • • , v `...;r • 7C7.7-1 5 11, , , • -3 12 .T.1 C1,3 ! 452 (A LI -- .11 br.r..IAL ZH rt , _ LINIF10 A4' CF 1 lL 12 ILL 2'! 1 31, • A - 0." I ,. .11.1r17, NO SCALE tit 0 1 yaw 1 7. 4. tr i BUILDING KEY PLAN GENERATOR ROO DESIGN DRAWINGS PROJECT: KING COUNTY DATA CENTER AT SABEY CORP TUK 5 BUILDING SBC 5201 3355 S. 120th Place Tukwila, WA 98168 REGISTRATION: REVISIONS: 140 DATE DESCRIPTION 10/3/07 SCHEMATIC HVAC DESIGN FOR REVIEW 11/13/07 DESIGN DEVELOPMENT r■r rlawlp.■1.• r■• 12/5/07 PERMIT SET McKINSTRY DIVISION: ENGINEERING DESIGNED BY: T. DIAZ DRAWN BY: B. HUCKINS CHECKED BY: M. WEBB JOB NUMBER: 35776 DATE: 9-28-07 SCALE: SEE DRAWING SHEET TIME: PLUMBING 1ST FLOOR PLAN SHEET NUMBER: instr le Of Your Building P2.1 SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 www.mckinstry.com I EXPIRES: 05-11-09 RECEWD DEC 2 6 2007 PERMiT CEN rF ISOLATION VALVE (TYP) NO 4 —I6N I 1" FOS 16 NC' EMERGENCY FILL SOLENOID VALVE NORMAL FILL SOLENOID VALVE BYPASS VALVE NC 1 NO �. FUEL OIL SUPPLY LD —N LEAK DETECTOR �I NC 1 "BYPASS —IFS FUEL OIL OVERFLOW LEVEL CONTROLLER PRIMARY TANK EMERGENCY VENT M6.0 DAY TANK WILL INCLUDE: TO FUEL OIL RETURN FLOW SWITCH 1" FOS NOT TO SCALE 1 -1/2" I V NOTE: ONE RETURN PUMP PER DAYTANK. SEE SCHEDULE, SHEET P7.0 (FOP 5202 —A & FOP 5202 -3) NORMAL VENT I CV FUEL OIL OVERFLOW PUMP (SEE NOTE) PRESSURE RELIEF VALVE SECONDARY TANK EMERGENCY VENT HIGH LEVEL ALARM I OVERFLOW PUMP ON `l FUEL PUMP OFF b FUEL PUMP ON EP LOW LEVEL ALARM ASV --- GENERATOR FUEL SUPPLY ■ FOR —I6 LG LEVEL GAUGE -I _1 DAY TANK PIPING DIAGRAM (TYP. EACH GEN. SET) FUEL OIL SYSTEM OPERATION NOTES: ANTISIPHON VALVE FIRE SAFETY VALVE FUEL PURIFIER (TYP) GEN. SET RUPTURE BASIN DIP TUBE (TYP) DOUBLE POPPET FOOT VALVE (TYP) FOR LEAK DETECTION SENSOR FOR CONTAINMENT FLOAT SWITCH TWO 5 LEVEL FLOAT SWITCH WITH BRASS STEM AND LOCKING RINGS, LOW LEVEL -- 45% FULL SUPPLY PUMP ON - 50% FULL ALL PUMPS OFF -- 85% FULL HIGH RETURN PUMP ON - 90% FULL HIGH LEVEL I LAG RETURN PUMP ON 95% FULL FUEL LEVEL GUAGE -- FRACTIONAL LEVEL INDICATION. • CONTROL PANEL (SHIPPED LOOSE; PROVIDED BY TANK MFR) SYSTEM REQUIREMENTS: 240 /1 PH, 60 HZ. FOS AS FUEL IS CONSUMED FROM THE DAY TANK, THE "SUPPLY PUMP ON" FLOAT WILL MAKE ON DROP, AUTOMATICALLY ENGAGING A SUPPLY PUMP. THE SUPPLY PUMP WILL REMAIN ENGAGED, FILING THE DAY TANK UNTIL THE "PUMPS OFF" FLOAT BRAKES ON RISE. PUMPS WILL AUTOMATICALLY ALTERNATE EACH TIME THE TANK CALLS FOR FUEL. IF THE FUEL SHOULD EVER REACH A LOW CONDITION, THE LOW LEVEL FLOAT SWITC WILL MAKE ON DROP. THE SYSTEM WILL DISPLAY A "LOW LEVEL" ALARM CONDTION AND SOUND THE PANEL MOUNTED ALARM BUZZER. IF THE FUEL SHOULD EVER EMPTY INTO A `FULL" TANK BEYOND THE PUMPS OFF FLOA THE RETURN PUMP FLOAT SWITCH WILL MAKE ON RISE. THE RETURN PUMP WILL ENGAGE UNTIL THE "PUMPS OFF" FLOAT MAKES ON DROP. IF THE FUEL SHOULD EVER REACH A HIGH LEVEL CONDITION, THE HIGH LEVEL FLOAT SWITCH WILL MAKE ON RISE. THE SYSTEM WILL DISPLAY A "HIGH LEVEL" ALARM CONDITION, SOUND THE PANEL MOUNTED ALARM BUZZER AND THE RETURN PUMP WILL ENGAGE. THE RETURN PUMP WILL REMAIN ENGAGED UNTIL THE "PUMP OFF" FLOAT MAKES ON DROP. IF LEAK DETECTOR SENSOR SWITCH MAKES, THE SYSTEM WILL DISPLAY A "DAYTANK BASIN LEAK DETECTED" ALARM CONDITION AND SOUND THE PANEL MOUNTED ALARM BUZZER. THE SUPPLY PUMPS WILL BE LOCKED OUT IF THE SYSTEM RECEIVES A LEAK DETECTED, OR A HIGH LEVEL OR LOW LEVEL SIGNAL UNTIL THE ALARM IS CLEARED AND THE SYSTEM IS RESET. 1"O'7' 2q 0 REVIEWED CEDE APPROVED 301( 'scab- City Of TUIY4IIa BO-DIN GENERATOR R00 DESIGN DRAWINGS V :ya PROJECT: KING COUNTY DATA CENTER AT SABEY CORP TUK 5 BUILDING SBC 5201 3355 S. 120th Place Tukwila, WA 98168 REGISTRATION: REVISIONS: NO DATE DESCRIPTION 10/3/07 SCHEMATIC HVAC DESIGN FOR REVIEW 11/13/07 DESIGN DEVELOPMENT 12/5/07 PERMIT SET McKINSTRY DMSION: ENGINEERING DESIGNED BY: T. DIAZ DRAWN BY: B. HUCKINS CHECKED BY: M. WEBB JOB NUMBER: 35776 DATE 9 -28 -07 SCALE: SEE DRAWING SHEET TITLE: PLUMBING DIAGRAMS AND DETAILS SHEET NUMBER: instr le Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503 - 331 -0234 www.mckinstry.com I EXPIRES: 05 -11 -09 RECEIVED DEC 2, 6 2007 PERMIT CENTER P6.0 SERVICE ID SERVICE DESCRIPTION LOCATION / AREA DESIGN PRESSURE (PSIG) SIZE MATERIAL CONNECTION TYPE & FITTINGS FLANGES, UNIONS & CPLGS FLEX CONNECTIONS EXPANSION JOINTS ISOLATION VALVE TYPE ISOLATION VALVE ACTUAL MFR & MODEL CHECK VALVE ACTUAL MFR & MODEL BALANCE VALVE MFR & MODEL STRAINERS ACTUAL MODEL PRESSURE GAUGES ACTUAL MODEL TEMPERATURE GAUGES ACTUAL MODEL TEST PROCEDURE NOTE: ISOLATE ALL EQUIPMENT PRIOR TO TESTING TEST PRESSURE (PSIG) [3] INSULATION CATEGORY SEISMIC BRACING IMPORTANCE FACTOR REMARKS MEDIA MINIMUM TEST PRESSURE MAXIMUM TEST PRESSURE MINIMUM DURATION FOV FUEL OIL VENT ALL 25 2° AND SMALLER CARBON STEEL PIPE A53B ERW STANDARD WEIGHT SOCKETWELD WHERE CONCEALED OR INACCESSIBLE, THREADED ELSEWHERE M.I. UNION Anvil Fig. 463 Class 150 300 psi WOG INCLUDED IN FUEL PACKAGE SUBMITTAL NA MOTOR TYPE NA NA VOLTAGE/PHASE 208/230 1 PH 208/230 1 PH MOTOR EFFICIENCY WATER OR AIR WATER: 150% OF MAX.OPER. PRESSURE AIR: 110% OF MAX. OPER. PRESSURE, NOT LESS THAN 5 PSIG MAX. ALLOWABLE TEST PRESSURE ANY COMPONENT OR 90% OF YIELD NOT LESS THAN 10 MINUTES, LOWER TO DESIGN PRESSURE FOR 24 HOURS AND PERFORM A VISUAL INSPECTION WITH NO LEAKS NO STARTER, DISCONNECT 1.5 BY ELEC. 2 -1/2" AND LARGER BUTTWELD 150# WELD NECK FLANGE FOS & R FUEL OIL SUPPLY & RETURN ALL 125 2" AND SMALLER PVDF DOUBLE WALL PIPE SOCKETWELD WHERE CONCEALED OR INACCESSIBLE, THREADED ELSEWHERE M.I. UNION Anvil Fig. 463 Class 150 300 psi WOG INCLUDED IN FUEL PACKAGE SUBMITTAL WATER OR AIR WATER: 150% OF MAX.OPER. PRESSURE o AIR: 110% OF MAX. OPER. PRESSURE, NOT LESS THAN 5 PSIG MAX. ALLOWABLE TEST PRESSURE ANY COMPONENT OR 90% OF YIELD NOT LESS THAN 10 MINUTES, LOWER TO DESIGN PRESSURE FOR 24 HOURS AND PERFORM A VISUAL INSPECTION WITH NO LEAKS 1.5 2 -1/2" AND LARGER BUTTWELD 150# WELD NECK FLANGE GEX GENERATOR EXHAUST ALL 150 ALL CARBON STEEL PIPE A53B ERW STANDARD WEIGHT BUTTWELD 150# WELD NECK FLANGE PROVIDED BY OTHERS UNISOURCE SERIES CF N/A N/A N/A N/A GENERATOR EXHAUST TO 1100 1.5 TAG # FOP - 5201 -A, 5201 -B FOP - 5202 -A, - 5202 -B QUANTITY 2 2 BASIS OF DESIGN RED JACKET RED JACKET MODEL NUMBER P7551 P7552 SERVICE FUEL OIL FUEL OIL LOCATION MAIN FUEL OIL TANK FUEL OIL DAY TANK FLOW 40 GPM 40 GPM FT. TOTAL HEAD 60 60 MAX FLUID PRESSURE PSIG CHILLED WATER 40 -55 0.23 -0.27 %g GLYCOL IN FLUID NONE NONE MOTOR HP 3/4 3/4 MOTOR BRAKE HP NA NA MOTOR TYPE NA NA VOLTAGE/PHASE 208/230 1 PH 208/230 1 PH MOTOR EFFICIENCY PER WSEC PER WSEC VFD NO NO STARTER, DISCONNECT BY ELEC. BY ELEC. WEIGHT PIPE & EQUIPMENT INSULATION SCHEDULE PIPING SYSTEM TEMP RANGE THERMAL COND. MEAN RAT. TEMP. INSULATION MATERIAL INSULATION THICKNESS BY PIPE SIZE INSUL. HANGERS RUNOUTS TO 2" (2) 1" AND LESS 1 1/4" TO 2" 2 1/2 TO 4" 5" TO 6" OVER 6" NON - POTABLE COLD ALL 0.23 -0.27 75 FIBERGLASS 0.5 0.5 0.5 0.5 0.5 0.5 NOTES 4, 5 CHILLED WATER 40 -55 0.23 -0.27 75 FIBERGLASS 0.5 0.5 0.75 1.0 1.0 1.0 NOTES 4, 5 COIL CONDENSATE ALL 1 0.23 -0.27 75 FIBERGLASS 0.5 0.5 0.5 0.5 0.5 0.5 NOTES 4, 5 DAY TANK SCHEDULE TAG # DT -1 DT -2 QUANTITY 1 1 BASIS OF DESIGN ACE TANK ACE TANK MODEL NUMBER AC00280U2R1 AC00280U2R2 SERVICE FUEL OIL FUEL OIL LOCATION GENERATOR ROOM GENERATOR ROOM CAPACITY 280 GALLONS 280 GALLONS WEIGHT (EMPTY) 625 LBS 625 LBS NOTES HVAC PIPING SPECIFICATIONS NOTES 1 HOT AND COLD PIPES LARGER THAN 2 ": RIGID INSERTS. INSULATION CONTINUOUS THROUGH THE HANGER. SHEETMETAL SHIELD. 2 COLD PIPES 2" AND SMALLER: RIGID INSERTS. INSULATION CONTINUOUS THROUGH THE HANGER. SHEETMETAL SHIELD. 3 JACKETING: METAL JACKET (SEALED WEATHER TIGHT) WILL BE USED AT ALL EXTERIOR INSULATION EXPOSED TO WEATHER (I.E.ROOFTOP PIPING). PVC JACKET WITH RIGID RIGID CALCIUM SILICATE INSULATION WILL BE USED ON ALL HORIZONTAL PIPING AT OR NEAR THE FLOOR SUBJECT TO POTENTIAL FOOT TRAFFIC. PVC JACKET WILL BE UTILIZED ON ALL EXPOSED INSULATION WITHIN 6 FEET OF THE FLOOR ELEVATION (I.E. MECHANICAL ROOMS AND GARAGE HOSE BIBBS). PVC IS RECOMMENDED INSTEAD OF METAL IN EXPOSED AREAS DUE TO ITS RESILIENCY -METAL JACKETS DENT. FUEL OIL PUMP SCHEDULE SPECIFICATION SECTION 15131-3 .AX FLUID TEMPERATURE VISCOSITY I FT. NPSH NOTE: PUMPS ARE EXISTING IN BUILDING STORES. REVIEWED FOR CODE COMPLIANCE APPROVE City Of 'Tukwila ILDIN DWI ION MO72'O GENERATOR R00 DESIGN DRAWINGS instr y le Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503- 331 -0234 www.mckinstry.com PROJECT: KING COUNTY DATA CENTER AT SABEY CORP TUK 5 BUILDING SBC 5201 3355 S. 120th Place Tukwila, WA 98168 REGISTRATION: REVISIONS: NO DATE DESCRIPTION 10/3/07 SCHEMATIC HVAC DESIGN FOR REVIEW 11/13/07 DESIGN DEVELOPMENT 12/5/07 PERMIT SET McKINSTRY DMSION: ENGINEERING DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: SHEET NUMBER: I EXPIRES: 05-11-09 T. DIAZ B. HUCKINS M. WEBB 35776 9 -28 -07 SEE DRAWING SCHEDULES - PLUMBING RECE ED DEC 2 6 2007 PERMIT CENTER P7.0