Loading...
HomeMy WebLinkAboutPermit M07-292 - WESTFIELD SOUTHCENTER MALL - BANANA REPUBLICBANANA REPUBLIC 806 SOUTHCENTER MALL M07 -292 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: 806 SOUTHCENTER MALL TUKW Contractor: Name: OKITSU CONSTRUCTION INC. Address: 1428 WHITWORTH AV S , RENTON WA Contractor License No: OKITSCI959L8 DESCRIPTION OF WORK: MECHANICAL FOR TENANT IMPROVEMENT Value of Mechanical: $25,000.00 Type of Fire Protection: SPRINKLERS Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us BANANA REPUBLIC 806 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA DERRICK PRODIGALIDAD 13648 BURBANK BL , SHEARMAN OAKS CA MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 3 0 0 0 1 0 0 0 * *continued on next page ** Phone: Phone: 818 786 -8960 Phone: 206 714 -9969 Expiration Date: 06/28/2009 M07 -292 04/02/2008 09/29/2008 Fees Collected: $500.45 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 M07 -292 Printed: 04 -02 -2008 Permit Center Authorized Signature: Signature: Print Name: doc: IMC-10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Y s . 64.: ¢s,.. Permit Number: M07 -292 Issue Date: 04/02/2008 Permit Expires On: 09/29/2008 Date: I hereby certify that I have read and exal�d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied wi hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the perfo ance/Q work. I am authorized to sign and obtain this mechanical permit. Date: .4,0r. 3 �� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -292 Printed: 04 -02 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond - 10/06 806 SOUTHCENTER MALL TUKW BANANA REPUBLIC 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 5: Readily accessible access to roof mounted equipment is required. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: ** *FIRE DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -292 ISSUED 12/27/2007 04/02/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the M07 -292 Printed: 04 -02 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us manufacturer's installation instructions. (IIVIC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -292 Printed: 04 -02 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the pgrformance of work. Signature: Date: d oto Print Name: e-ab PIE V S W IT5 t doc: Cond -10/06 M07 -292 Printed: 04 -02 -2008 Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 lrtrp_ /7t•itar.ci. tuki iila. }ra. us NlrI fa y )iitei Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION �t King Co Assessor's Tax No. :e 420 / Sl.0 T i M Site Address: t YI ILL _ Suite N Floor: j Tenant Name: 7 44e 6A- ,� , /i- New Tenant: .% 0K Yes ❑ ..No Property Owners Name: ` ', t lE/ ��T ^ t. (® y► Mailing Address: 1' ( 'C Yi 1 1(i4 IRE 134/J) L% 5 CA qf/C25 CONTACT PERSON — who do we contact when your permit is ready to be issued E -Mail Address_dgirr14I a jvr.;'i pkte coot, ) . GENERAL CONTRkCTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: I d�FJ Mailing Address: r ` City Contact Person: Day Telephone: E-Mail Address: Fax Number. Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: i e 6 �` / �, s� �r Mailing Address: 50 4 %7'A) i sr ' Se 7/L jFibe9� v [ ;A ggme Zia Day Telephone: �.- 249 `e, 5 z Contact Person: ', �r J b VAIAWA , " E -Mail Address: 7GI4 . d Q:%AppliationsTonns- Applications On tine\3 -2006 - Permit Appliation.doo Revised 9 -2006 bh Building Permit No. 90+ Mechanical Permit No. AAA" 1- Plumbing/Gas Permit No. gb1)1 Public Works Permit No. Project No. p n �j ' 002 Ci ty (For once us:only) State Pawn- WL Day Tone - 14 N 4 -lig - ✓'r► n S •4) L r -- city St a. Fax Number: F)g* -Lay - 9 -5 ) Stale Fax Number. '/is zee -Big ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Q,7 (29A60477416. n .1 IM .R?S d n / �y� Mailing Address: (166 ott i 6'cieK.l /�.�I) At �7// V 7x 73 73 City State /, Zip Contact Person: J3 i� Day Telephone: J 12 '" r - ' /' E -Mail Address: Fax Number: 9Z 7 - 044 Page 1 of 6 BUILDING PERMIT INFORTION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1 • P4 Ul a Existing Building Valuation: $ Scope of Work (please provide detailed information): New 7i V44"7 . .fit' 'Vn T / iv -cZ L-. N eze, / t6 F,'x 7 1 /Nr a.Q /# s/ - Will there be new rack st . . ge? Yes ❑.. No If yes, a separate permit and plan submit will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (: - of the foundation of all structures, plus any decl \over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, p ' , vide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide docum : ion that shows that the principal owner lives in one of the dwe gs as his or her primary residence. Provided: Standard: Compact: Q:\Applications\Fonns- Applications On Line \3 -2006 - Permit Applicatioadec Revised: 9 - 2006 bb Floor area of accessory dwelling: Handicap: Number of Parking S Will there be a than ; in use? ❑ Yes ❑ No If `yes ", exp m: FIRE PRO ON/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None C], Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes If `yes ; attach list of materials and storage locations on a separate 8 - 1/2 "x 11" paper including quantities and Material Safety SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 0..i No 0+ to Sheets. Page 2 of 6 Existin Interior Remodel Addition to Existing Structure ew Type of Construction per IBC Type of Occupancy per IBC 1" Floor 37 V5 Ir / 2 Floor 3" Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORTION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1 • P4 Ul a Existing Building Valuation: $ Scope of Work (please provide detailed information): New 7i V44"7 . .fit' 'Vn T / iv -cZ L-. N eze, / t6 F,'x 7 1 /Nr a.Q /# s/ - Will there be new rack st . . ge? Yes ❑.. No If yes, a separate permit and plan submit will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (: - of the foundation of all structures, plus any decl \over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, p ' , vide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide docum : ion that shows that the principal owner lives in one of the dwe gs as his or her primary residence. Provided: Standard: Compact: Q:\Applications\Fonns- Applications On Line \3 -2006 - Permit Applicatioadec Revised: 9 - 2006 bb Floor area of accessory dwelling: Handicap: Number of Parking S Will there be a than ; in use? ❑ Yes ❑ No If `yes ", exp m: FIRE PRO ON/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None C], Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes If `yes ; attach list of materials and storage locations on a separate 8 - 1/2 "x 11" paper including quantities and Material Safety SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 0..i No 0+ to Sheets. Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor. Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System i Wood/Gas Stove 30 -50 HP /1,750,000 BTU _ Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat /Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment _ .,A � d l ��' Air Handling Unit <10,000 CFM /1 �7 Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: 1 BD Mailing Address: City State Tip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $` C , 1 Scope of Work (please provide detailed information): k) ' ) T 1IV k 7/ Atia- 61-1'ELL-- Use: Residential: New .... 0 Replacement .... Commercial: New .... 0 Replacement _Xi Fuel Type: Electric 0 Gas ....ID Other: Indicate type of mechanical work being installed and the quantity below: Q :Upplications\Forms- Appliations On Lined -2006 - Permit Appliation.doe Revised: 9 -2006 bn Page 4 of 6 PUBLIC WORKS PERMIT INFORMATION - 206 - 433 -0179 Scope of Work (please provide detailed information): W ter District ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District .Tukwila ❑ ...Sewer Use Certificate Septic System: ❑ On -site Septic System - For on -si Submitted with Application (mark box ❑ ...Civil Plans (Maximum Paper Size — ❑ ...Technical Information Report (Storm ❑ ...Bond - ❑ .. Insurance Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 ho ❑ .. Right -o : y Use - Profit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ .. Righ s f -way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ .. Abandon ❑ ...Cap or Remove Utilities ❑ .. Curb ❑ ...Frontage Improvements ❑ .. Pav ❑ ...Traffic Control ❑ . ❑ ...Backflow Prevention - Fire Protection ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. " ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension. ' ublic ❑ ...Water Main Extension ....Public FINANCE INFORMATIO Fire Line Size at Prope ine ❑ ...Water Monthly Service Bill' : to: Name: Mailing Address: ❑ ...Sewer Irrigation Domestic Water If » Q: Applicationaonns- Applications On line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ...ValVue ❑ .. Renton ...Sewer Availability Provided septic system, provide 2 copies of a current septic design approv by King County Health Department. hich apply): N A x 34") age) ❑ .. Geotechnical Repo . Easement(s) ❑ .. Maintenance A T Cut Fire Line ❑ .. Highline .. Work in Flood Zone ❑ .. Storm Drainage Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment ❑ .. Renton ❑ .. Seattle ❑ ...Traffic Impact Analysis ent(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding wo # WO # WO # ❑ ...Ded Water Meter Size Private Private Day Telephone: city State Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip Page 3 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the. Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. wilding and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). ,r' Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING $ WNFR! n Signatut Print Name: _ d)'r . k jj _ Mailing Address: 104 Tg eliT e•x r • V Date Application Expires: 0.12101 Date Application Accepted: v..1 941 Q:UpplicetionsWonns- Applications On tine 3 -2006 - Permit Applic•tiondoc Revised 9-2006 un Date: I zJz9. /o _ Day Telephone: e.j� 7 '� - e' yr , ' of ZS12{,r. r_ s Oh- 11 1 City state Zip Staff Initials: , Page 6 of 6 1 Fixture Type: Qty Fixture Type: Qty ` xture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) ' fountain Gas piping outlets Bidet Food -waste grinder, commercial ' _ • • in direct waste Clothes washer, domestic Floor drain 1 Sinks Dental unit, cuspidor Shower, single head : * Urinals Dishwasher, domestic, with independent drain Lavatory /L Water Closet Building sewer or trailer park sewer Rain water sy i' — per drain (inside b ding) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alt:. ation of water piping an +r water treating equipm ' Repair or alteration of drainage or vent piping Medical gas piping system serving one to five ets/outlets for specific gas Contact Person: E-Mail Addr - • : Contractor Regis on Number: PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: 1 13.E Mailing Address: Valuation of Plumbing wo contractor's bid price): $ IC Valuation of Gas Piping work • retractor's bid price): $ Scope of Work lease provided information): 2 % ' /ivc wer,541 n5 I-ki r we - - / bTh Building Use (per Int'l Building Code): f Occupancy (per Int'l Building Code): 10 Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being Q:\ApplicationsWorms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip City Day Telephone: Fax Number: Expiration Date: Se er: and the quantity below: Page 5 of 6 RECEIPT NO: R08 -01014 Initials: JEM Payment Date: 04/02/2008 User ID: 1165 Total Payment: 623.96 Payee: OKITSU CONSTRUCTION, INC. SET ID: 0324 SET NAME: BANANA REPUBLIC SET TRANSACTIONS: Set Member Amount M07 -292 417.96 PG07 -349 206.00 TOTAL: 623.96 TRANSACTION LIST: Type Method Description Amount Payment Check 1636 623.96 TOTAL: 623.96 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLUMBING - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us SET RECEIPT Account Code Current Pmts 000/322.100 417.96 000/322.100 206.00 TOTAL: 623.96 RECEIPT NO: R07 -02863 Initials: JEM Payment Date: 12/27/2007 User ID: 1165 Total Payment: 1,575.93 Payee: PERMIT PLACE, INC. City of Tukwila SET TRANSACTIONS: Set Member Amount Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us SET ID: S000000928 SET NAME: Tmp set/Initialized Activities D07 -484 1,274.44 EL07 -808 184.50 M07 -292 82.49 PG07 -349 34.50 TOTAL: 1,575.93 Payment Check 7003 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: TRANSACTION LIST: Type Method Description Amount 1,575.93 1,575.93 Account Code Current Pmts 000.345.832.00.0 184.50 000/345.830 1,391.43 TOTAL: 1,575.93 6533 12/27 9710 TOTAL 1575.93 Project: D �cvaZ--- T G y of inspection: F h o / Address: / o� 1Ki Date Called: Special Instructions: - -- - Date Wanted: ? Az q _ � tr . a.m. p.m. Requester: Phone No: INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20 Gee #16 1 4 - OMMENTS: 4-/ c._■1()/e..77 'Inspector: $58.0 pai Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. Date: 2 E NSPECTION FEE REQUIRED. Prior to inspection, fee must be 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: (Date: Project: AAtiA 4e,01 /6/ Type of Inspection: C F7/114 / Addr // (O flhi // Date Called. Special Instructions: Date W _ ��JJ a r Requester: Phone No ,oC .- 3 37/ - 7 Inspector: 'Receipt No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. f Corrections required prior to approval. COMMENTS: i rc 4,. / ?/'gar ±2 Al ec/i . 'i /I t Date: 747'4 r1 EJ $60.00 NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Date: COMMENTS: Vla'+1- % Qi-kw. 1 1 dd• -ss 1io. /OL - fence Ce ".45 L4p,i4- !�4L f'� /� 'V 0 V -2 /te 4.... -.-.1 4 ✓ ie SS flu. I ti -2- / Q °k5C-e4/ S' -Yvan1 (Ant 4- Cric -IL. \4V-3 12.E t -urn il. d , e5, n o . 10 (0 - p455,d - r ✓4S v►n t-- . / AC-!C Special Instructions: Date Wanted: -7iZlt, a.m. p.m. Requester: Phone No: Project: . Ran nnG. Re f .iii of Inspection: Srnor.t d. , N Address: To Iv - ,1` ` Date Called: Special Instructions: Date Wanted: -7iZlt, a.m. p.m. Requester: Phone No: c„. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION` 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 .Approved per applicable codes. nspector. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Date: -.7 /2 / dr 0 1-292- Corrections required prior to approval. 'Receipt No.: 'Date: Projec Type of Inspection: " Address 'cx V'\\ Date Called: Special Instructions: Date Wanted: a.m. 7. 1• t p.m. Requester: Phone z� g�- - rb- si l o Inspector: INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Date: r - Z ° l L PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g.". 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 COMMENTS: Corrections required prior to approval. •CO $60.00 REINSPECTION FEE REQUI - ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Proje 13 Ak1A &III \ Type Inspectioni . Ad-ss: •60( Y0 4 (1 Date Called: Special Instructions: Date Wanted: Requester: Phone .L' ---.." ti 3 3 7 f 7 INSPECTION RECORD Retain a copy with permit 11 67 Z_S 7 INSPECTION NO. PERMIT NO. it-- CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2'06)431-3670 ID Approved per applicable codes. 'Inspector: 4 I Receipt No.: El Corrections required prior to approval. COMMENTS: Ceipi 1)7' hfr Date: s 4 7 4 r , $5863EINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 SouthcenterBk*Suite 100. Call the schedule reinspection. 'Date: tt I? 1 PERMIT . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project::/ ,� a Type of Inspec on: Address `460/ 4,el � . It= 444 *re? b V /" m / 'A Date Called: / Special Instructions: eft INSPECTION NO. El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Date Wanted: 1 5 A" Requester: Phone No: 793 37/7 Corrections required prior to approval. COMMENTS: X74 ,Oifre G 1 Gr,s CO,047/ dk -tor eel/ 1 $5$'86 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Pro' 5 /1 NI OVA CZ.P'Pitoi,? Type of spection: t(i(n --4i‘) Ad ¢Egs .7 ^ C CJ( I v ` r-t ' ` Date Called: Special Instructions: ---- Date Wanted: — z z -- Requester: 2_60 " 37/7 Ph Nom Z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION . 4 2 s 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- Approved per applicable codes. COMMENTS: ,4 0W ' sKR( �. hrac ukra Inspector: / $58. INSPECTION FEE REQUIRED. 6300 Date: . El QUIRED. Prior to inspection, fee must be p ai S ou th ter ce er lvd., Suite 100. Call the schedule reinspection. Receipt No.: INSPECTION RECORD Retain a copy with permit 11i .corrections required prior to approval. Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 Project: 4 k1.6 El Approved per applicable codes. 1h02-2/2 Address: Special Instructions: Type of Inspection: 12 (', 26) Date Called: Date Wanted: ( I- 2 2-2r a.m. P.m. Requester: Phone No: 224:7/5 37/7 EJ Corrections required prior to approval. COMMENTS: 1 A I I 4r/ 5 rye-p-t- Date: ( 1 - 2Z- - v 8 I 'Inspector: .••• $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: ...••.# 5 1 d 575 Project: - % ;, N fk, 0 >R i1(, e ( Type of Inspection: to 0 - 1 - c A-bC, � . Address: r `= ) �., , � / ,(776 �, .� ( � , , 1 t-- Contact Person: Suite #: _, L I A fU `� . 4-i 4 _I Special Instructions: Phone No.: Needs Shift Inspection: '. Sprinklers: Fire Alarm: '� Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 'b'i v PERMIT NUMBERS 444 Andover Park East, T ukwila Wa. 98188 -- gi Approved per applicable codes. ri Corrections required prior to approval. Inspector: Date: 7/i/68 Hrs.: \p' $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 ...••.# 5 Needs Shift Inspection: '. Sprinklers: Fire Alarm: '� Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 'b'i v PERMIT NUMBERS 444 Andover Park East, T ukwila Wa. 98188 -- gi Approved per applicable codes. ri Corrections required prior to approval. Inspector: Date: 7/i/68 Hrs.: \p' $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 'b'i v PERMIT NUMBERS 444 Andover Park East, T ukwila Wa. 98188 -- gi Approved per applicable codes. ri Corrections required prior to approval. Inspector: Date: 7/i/68 Hrs.: \p' $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 PLAN REVIEW /ROUTING SLIP PERMIT COORD COPY ACTIVITY NUMBER: M07 -292 DATE: 02 -19 -08 PROJECT NAME: BANANA REPUBLIC SITE ADDRESS: 806 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 Mfermit Issued DEPARTMENTS: q P Buil g ivision Public Works ❑ Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Incomplete n Structural Review Required E DUE DATE: 02-21-08 Not Applicable C Planning Division Permit Coordinator C No further Review Required DATE: n DUE DATE: 03-20-08 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 -292 DATE: 12 -27 -07 PROJECT NAME: BANANA REPUBLIC SITE ADDRESS: 806 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: r, [(1 Bui ng i vision , Public Works Comments: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 511 AwG ( Fir e Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete yij Incomplete ❑ APPROVALS OR CORRECTIONS: Approved C Approved with Conditions Notation: REVIEWER'S INITIALS: n ❑ Permit Coordinator n DATE: Planning Division DUE DATE: 01-03-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required DATE: DUE DATE: 01-31-08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 9—k I Oi -(11� 4 S ummary of Revision: CP t - • tilt, 7 Received by: o r wi .o(./ - .,0 - A.0O l i J or Gi • w Received by: ROD O/,4TTS f A REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: - Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS S ummary of Revision: Received by: PROJECT NAME: SITE ADDRESS: REVISION LOG PERMIT NO: J e)" _ 1 L ORIGINAL ISSUE DATE: ` 414 (please print) (please. print) (please print) (please print) (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: feinaU Rt 11 2o0$ Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # [A.. Revision # after Permit is Issued Do-11,w .iD -21t ju- - W fro-- 1-101 ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Banana Republic 44991 Qxu %after k441l Project Address:SO b SocI icenter Nlptt Yukwila,WA cmisb Contact Person: 11 Pea 7kGPcIAVA s7 Summary of Revision: Sheet Number(s): ( LIO Sirreti "ID 112 1 "Cloud" or highlight all areas of revision including date of r : ision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Phone Number: S € .1450 . sg Steven M Mullet, Mayor Steve Lancaster, Director Ptoe- SAMS AREA origin4 I (p.) 1)ioin sttlet areas -turned into (3) main rata area S- Crocoevoid : man a get ss affic m ova oddifon of- go- back closet 1/ License Information License OKITSCI959L8 Licensee Name OKITSU CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602515973 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 1428 WHITWORTH AVE S Address 2 City RENTON County KING State WA Zip 98055 Phone 2067149969 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/28/2005 Expiration Date 6/28/2009 Suspend Date Separation Date Parent Company Previous License OKITSC*030R3 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date OKITSU, RODNEY STERLING AGENT 06/28/2005 OKITSU, RODNEY STERLING PRESIDENT 06 /28/2005 r -- - - --- - -- .r ..,.,...,., •,'.,..... Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 a51, 1 vi c, https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= 0KITSCI959L8 04/02/2008 RESPONSIBILITY MATRIX LEGEND DRAWING SCHEDULE STOREFRONT EXTRUSION 0 GC FACTORY FINISHED M1 -0 MECHANICAL PLAN M2 -0 MECHANICAL SCHEDULES T L = LANDLORD 1 FURNISHED BY M2 -1 MECHANICAL DETAILS COMMENT PLUMBING PLAN AND SCHEDULES M3 -1 ITEM O = OWNER (GAP INC.) FIRE SPRINKLER PLAN M5 -0 MECHANICAL SPECIFICATIONS M5 -1 GC= GENERAL CONTRACTOR M5 -2 MECHANICAL SPECIFICATIONS I INSTALLED BY I RESPONSIBILITY MATRIX VAV BOXES 0 GC VAV BOX THERMOSTAT 0 GC REMARKS: 1. GENERAL CONTRACTOR TO COORDINATE SCHEDULE AND DELIVERY WITH SUPPLIER. STANDARD SHIPPING PROVIDED BY GAP INC. ANY EXPEDITED SHIPPING COSTS ARE RESPONSIBILITY OF THE GENERAL CONTRACTOR. NOTE: 1. THE RESPONSIBILITY MATRIX ONLY DELINEATES ITEMS SUPPLIED AND /OR INSTALLED BY OWNER AND /OR LANDLORD. ANY WORK BY CONSTRUCTION DOCUMENTS NOT DEFINED AS RESPONSIBILITY OF OWNER OR LANDLORD IS SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. SEE BID CLARIFICATION LETTER FOR ANY VARIATION BY SCOPE OF WORK RESPONSIBILITY. 2. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE UNLOADING OF ANY OWNER SUPPLIED CONSTRUCTION ITEMS. APPLICABLE CODES HAVING JURISDICTION OVER THIS PROJECT DRAWING SCHEDULE NUMBER TITLE MO -0 MECHANICAL NOTES AND LEGEND M1 -0 MECHANICAL PLAN M2 -0 MECHANICAL SCHEDULES M2 —Oa MECHANICAL SCHEDULES M2 -1 MECHANICAL DETAILS M3 -0 PLUMBING PLAN AND SCHEDULES M3 -1 PLUMBING DETAILS AND RISERS M4 -0 FIRE SPRINKLER PLAN M5 -0 MECHANICAL SPECIFICATIONS M5 -1 MECHANICAL SPECIFICATIONS M5 -2 MECHANICAL SPECIFICATIONS APPLICABLE CODES HAVING JURISDICTION OVER THIS PROJECT BUILDING CODE 2006 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMENDMENTS MECHANICAL CODE 2006 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMENDMENTS PLUMBING CODE 2006 UNIFORM PLUMBING CODE W/ WASHINGTON AMENDMENTS ELECTRICAL CODE 2005 NATIONAL ELECTRIC CODE W/ WASHINGTON AMENDMENTS FIRE & LIFE SAFETY CODE 2006 INTERNATIONAL FIRE CODE W/ WASHINGTON AMENDMENTS ENERGY CODE 2006 WASHINGTON NONRESIDENTIAL ENERGY CODE r HVAC GENERAL NOTES 1. THE ABBREVIATION G.C. WHEREVER IT APPEARS IN THESE MECHANICAL AND ELECTRICAL DRAWINGS SHALL REFER TO THE GENERAL CONTRACTOR. 2. THE CONTRACTOR FOR THE DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE HVAC SYSTEMS SHALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR. COORDINATE ROOF PENETRATION REQUIREMENTS WITH LANDLORD AND G.C. VERIFY SCOPE OF WORK WITH G.C. PRIOR TO BID AND INCLUDE ALL COSTS IN BID AS DIRECTED BY G.C. 4. THE CONTRACTOR SHALL COORDINATE WITH G.C. ON ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT MECHANICAL EQUIPMENT PER DETAILS SHOWN ON STRUCTURAL PLANS. THE CONTRACTOR SHALL COORDINATE LOCATIONS AND REQUIREMENTS WITH G.C. AND LANDLORD. VERIFY SCOPE OF WORK WITH G.C. PRIOR TO BID AND INCLUDE ALL COSTS IN BID AS DIRECTED BY G.C. 5. THE CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT BEING USED OR SHOWN TO REMAIN, IS FULLY REMOVED AND NOT ABANDONED. COORDINATE REQUIREMENTS WITH G.C. AND LANDLORD. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. VERIFY SCOPE OF WORK WITH G.C. PRIOR TO BID AND INCLUDE ALL COSTS IN BID AS DIRECTED BY G.C. 6. INSTALL ALL LOW VOLTAGE CONTROL WIRING FOR THE TEMPERATURE CONTROL SYSTEM. COORDINATE WITH THE ELECTRICAL CONTRACTOR FOR CONTROL SYSTEM CONDUIT AND POWER REQUIREMENTS. COORDINATE EXACT LOCATION WITH THE G.C. FOR ALL TEMPERATURE CONTROL COMPONENTS. 7. INSTALL IDENTIFICATION ON ALL HVAC EQUIPMENT. PROVIDE STENCIL WITH A MINIMUM OF 4" HIGH BLACK SPRAY PAINTED LETTERS, INDICATING TENANTS NAME, HVAC UNIT NUMBER AND SPACE NUMBER, VERIFY ADDITIONAL REQUIREMENTS WITH LANDLORD. 8. CONTRACTOR TO VERIFY THAT ALL ITEMS ON CONTRACTOR CHECKLIST ARE COMPLETED PRIOR TO MEP COMMISSIONING. CONTRACTOR WILL RECEIVE CONTRACTOR CHECKLIST IN ELECTRONIC FORM WITH BID DOCUMENTS. 9. ALL SYSTEMS, EQUIPMENT, AND /OR BUILDING COMPONENTS SHALL COMPLY WITH THE APPLICABLE MANUFACTURER PROVISIONS AND INSTALLATION PROVISIONS OF TITLE 24, PART 6, CHAPTER 2, SECTIONS 111 THROUGH 119. SEPARATE PERMIT REQUIRED FOR: 0 Mechanical (Electrical g Plumbing lVGas Piping City of Tukwila i 4.4,11..plt. G DIVISION ISOC an es�_, . a:�1:. ` trsI!t �eC7 p ©f w ork �. "•,'=title;. pilot �. a of NOTE: r will require a new plan submittal and m ay include additional plan review fees. FILE _ ! PY � Permit No, Plan review approval Is subject to anal and ornioslons. Approval of construction docwnents does not authorize the violation of any adopted code or ordinance. Recut of approved Field; ' _ conditions Is asCiq'laulled8ed: By , sa . toy. O?) City of Tukwila BUILDING DIVISION Date: MECHANICAL SYMBOLS ON OFF AUTO o--- ›.?<, ri‹ v e 3— POSITION SWITCH 2 —WAY CONTROL VALVE 3—WAY CONTROL VALVE ACCESS PANEL. SEE ARCHITECTURAL DRAWINGS BUTTERFLY VALVE CHECK VALVE CEILING EXHAUST FAN CLOSES ON PRESSURE RISE CLOSES ON TEMPERATURE RISE COMBINATION FIRE /SMOKE DAMPER COMBINATION BALANCE /SHUT —OFF CONCENTRIC DUCT TRANSITION CONTROL DAMPER CONTROL RELAY SOLENIOD DETAIL SYMBOL DRAIN VALVE DUCT MTD. SMOKE DETECTOR DUCT MOUNTED SUPPLY REGISTER DUCTWORK TRANSITION — RECTANGULAR TO ROUND ECCENTRIC DUCT TRANSITION ELECTRIC BASEBOARD HEATER (EBBH) EQUIPMENT SYMBOL FLEXIBLE DUCT CONNECTION FLEXIBLE DUCT FIRE DAMPER FUSE GATE VALVE GLOBE VALVE INLINE PUMP INTERNALLY LINED DUCT 0 r— ) 00- TEMP. SENSOR — MOUNT 60" AFF d THERMOSTAT — MOUNT 48" AFF �w MAGNETIC MOTOR STARTER COIL MOTORIZED DAMPER OPENS ON PRESSURE RISE OPENS ON TEMPERATURE RISE P & T RELIEF VALVE PILOT LIGHT P.O.C.: POINT OF CONNECTION PRESSURE GAGE RELAY RETURN DUCT ELBOW UP OR DOWN RETURN GRILLE ROUND DUCT — DOWN ROUND DUCT — UP SECTION SYMBOL SIDEWALL MOUNTED SUPPLY REGISTER SUPPLY DIFFUSER SUPPLY DUCT ELBOW UP OR DOWN TEMP /LTG CONTROL PANEL (TLCP) THERMOMETER TRANSFORMER TURNING VANES UNION UNIT HEATER (UH) VOLUME DAMPER Y— STRAINER MECHANICAL ABBREVIATIONS Al AO AUX AWG CD COM CV CV DC DI DO EA EOL FACP FDM FM GND H HOA L HR LS MD MIN MOD NC NO OA OL OVR PT RA RES RVR SD SMD TDM TS V VA VAC WSHP X XMFR WMS ANALOG INPUT ANALOG OUTPUT AUXILLIARY AMERICAN WIRE GAUGE CONTROL DAMPER COMMON CONTROL VALVE VALVE COEFFICIENT DIRECT CURRENT DIGITAL INPUT DIGITAL OUTPUT EXHAUST AIR END OF LINE FIRE ALARM CONTROL PANEL FLOW DISPLAY MODULE FLOW METER GROUND HOT HAND OFF AUTO HEATING RELAY LINE VOLTAGE LIQUID SENSOR MINIMUM OR MODULATING CONTROL DAMPER MINIMUM MODULATING NEUTRAL NORMALLY CLOSED NORMALLY OPEN OUTDOOR AIR OVERLOAD OVERRIDE PROGRAMMABLE THERMOSTAT RETURN AIR RESISTOR REVERSING VALVE RELAY SUPPLY DIFFUSER SMOKE DETECTOR TEMPERATURE DISPLAY MODULE TEMPERATURE SENSOR VOLT VOLT AMPERE VOLT ALTERNATING CURRENT WATER SOURCE HEAT PUMP TRANSFORMED TRANSFORMER WIRE MESH SCREEN CIT DE 'EF RECEIVED . OP it KKA A 2 7 2007/ Mai CENTER SHEET NUMBER: M O-O NEW STORE BANANA REPUBLIC GAP INC, CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188-2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/1 5/07 OPENING 2008 CONSULTANT INFO: Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSI A L STAMP 4 4 SI Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Sheet Suite 710 San Francisco CA 94108 1.415.288.8150 1. 4 1 5 2 8 8. 8 1 8 1 www.mccalldeslgn.com ISSUE TYPE: LL /PERMIT /BID 12/21 /07 ISSUE SCALE: NOT TO SCALE DRAWN BY: PJR/WKK JOB NO.: 207338 SHEET TITLE: MECHANICAL NOTES AND LEGEND EF 2 22x26 12 "0 SD -3 319 1 (E)14" TE \NOMFNl 1(I) , LE_ r I? )�� A ll:. 71 ID TG— E XI T 1 ( F )2 x.2.12 11 A,I ( \NAY /c400 M FITTING ROOM MGR'S TILL T ROOM ' r AREA OFFICE RLTURNd AIR r)FLNIN i (BY LANDLORD' SD -4 20 L SD -4 20 ( i) 071[ 17/ 11_</ SD -2 SALES AREA .3 484 RD -1 656 FPB -2 0 00 /2 >CO1l[ r ` ALL`jAREA 2 RD -1 514 SD -2 359 O ]� SD -2 3 :5 FP 1 SALES AREA 1 LOCI p EN B oa MECHANICAL PLAN M1-0 1/8" PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) 'I SRI. AY :REA 1 TRY !SPLAY .REA. 2 -6! HVAC CODED NOTES 100) PLACE "AS— BUILT" MECHANICAL DRAWINGS IN DRAWING TUBE. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 304) DUCT MOUNTED SMOKE DETECTOR. WIRE THE THERMOSTAT FAN WIRE THROUGH THE NORMALLY CLOSED CONTACT ON THE SMOKE DETECTOR TO SHUT DOWN THE HVAC UNIT UPON SENSING SMOKE. SMOKE DETECTOR MUST BE INSTALLED IN AN ACCESSIBLE LOCATION. INSTALL REMOTE TEST /RESET STATION AS REQUIRED. COORDINATE LOCATION OF TEST STATION WITH G.C.. 305) FIRE DAMPER WITH ACCESS DOOR IN DUCT PENETRATING FIRE —RATED PARTITION. LABEL ACCESS DOOR WITH 2" HIGH STENCILED LETTERS IN BLACK ENAMEL PAINT DESIGNATING "FIRE DAMPER ACCESS ". LOCATE ACCESS DOOR ON ACCESSIBLE SIDE OF PARTITION. (306) FAN POWERED VARIABLE — AIR -- VOLUME PARALLEL BOX. SUSPEND FROM STRUCTURE WITH IN —LINE COMBINATION RUBBER AND SPRING VIBRATION ISOLATORS. 309 AIR DEVICE TO BE USED AS ACCESS TO EQUIPMENT ABOVE CEILING. VERIFY THAT SWING OF DEVICE WILL NOT INTERFERE WITH OTHER CEILING ELEMENTS. (310) ROUTE TOILET EXHAUST DUCT TO EXISTING LANDLORD SUPPLIED TOILET EXHAUST HEADER. FIELD VERIFY LOCATION AND SIZE OF EXISTING HEADER. NOTIFY G.C. IF HEADER SIZE WILL NOT SUPPORT DUCT CONNECTION. (400) CONNECT NEW SUPPLY DUCTWORK TO EXISTING LANDLORD PROVIDED SUPPLY DUCT TAP. FIELD VERIFY SIZE AND LOCATION OF EXISTING TIE --IN POINT PRIOR TO BID. 401) 36 "x18" TRANSFER AIR OPENING. LOCATE OPENING HIGH AS POSSIBLE. COORDINATE EXACT LOCATION WITH OTHER DISCIPLINES. PROVIDE GRILLE (TG --1) ON EXPOSED SIDE OF OPENING. HVAC GENERAL NOTES 1. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS. 2. DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE. 3. TENANT SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIR FLOW BACK TO LANDLORD AIR CONDITIONING UNIT. GENERAL NOTES 1. ALL ROUND AND FLAT OVAL SUPPLY, RETURN AND EXHAUST DUCTWORK SHALLBE LINDAB, UNITED MCGILL OR SEMCO DUCT SYSTEMS CONSISTING OF FITTINGS THAT ARE FACTORY FITTED WITH A SEALING GASKET AND SPIRAL DUCT WHICH, WHEN INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS, WILL SEAL THE DUCT JOINTS WITHOUT THE USE OF DUCT SEALER. MATERIALS: ALL DUCT AND FITTINGS SHALL BE G -90 OR G -60 GALVANIZED. 2. SUBMITTALS: SUBMIT MANUFACTURER'S DUCT SYSTEM CATALOG DATA FOR REVIEW AND APPROVAL SUBMIT SHALL INCLUDE DUCT, FITTING AND SELF SEALING GASKET CATALOG INFORMATION. SURVEY INFORMATION SPACE IS LOCATED ON LEVEL FINISHED FLOOR TO BOTTOM OF DECK ABOVE IS APPROX 1 _OF„_1 17' -5" FINISHED FLOOR TO BOTTOM OF LOWEST STRUCTURAL MEMBER (STEEL OR CONCRETE BEAMS) IS APPROX 17' -5" FINISHED FLOOR TO BOTTOM OF JOIST IS APPROX 17' -5" NOTE: CONTRACTOR IS TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF G.C.'S CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID. DUCTWORK SHALL NOT BE FABRICATED OR ANY EQUIPMENT ORDERED PRIOR TO APPROVAL BY G.C.'S CONSTRUCTION MANAGER. PE • RECEIVED _ ON THE DRAWINGS. ALL OTHER EQUIPMENT, PIPING, AND DUCTWORK ELEVATIONS ARE AS NOTED RMIT CENTS REVI MA 212 BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 NEW STORE STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: _k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSION EXPIRES 0 2/o6/Z010 Firm Registration No. 2002 ARCHITECT INFO: McColl Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t . 4 1 5. 2 8 8. 8 1 5 0 f.415.288. www.mcCalidesign.com R ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: 1/8" =1' -0" DRAWN BY: HVVR/WKK JOB NO.: 207338 SHEET TITLE: MECHANICAL PLAN ION NO ,!- SHEET NUMBER: M1—O Air System Sizing Summary for BLOCK LOAD Air System Information Air System Name blockload Number of zones 1 Equipment Class UNDEF Floor Area 3766.0 ft Air System Type VAV Location Seattle IAP, Washington Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Calculation Months Jan to Dec Space CFM Coincidentspace Toads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 6.9 Tons Load occurs at Jul 1600 Total coil load 83.2 MB H OA DB / WB 84.5 / 64.8 °F Sensible coil load 78.2 MBH Entering DB / WB 72.0 1 62.3 °F Coil CFM at Jul 1600 5125 CFM Leaving DB / WB 57.6 / 56.7 °F Max block CFM at Jan 1900 5307 CFM Coil ADP 56.1 °F Sum of peak zone CFM 5307 CFM Bypass Factor 0.100 Sensible heat ratio 0.940 Resulting RH 64 % ft 543.3 Design supply temp. 58.0 °F BTW(hr -ft 22.1 Zone T -stat Check 1 of 1 OK Water flaw @ 10.0 °F rise 16.65 gpm Max zone temperature deviation 0.0 °F Supply Fan Sizing Data Actual max CFM at Jan 1900 5307 CFM Fan motor BHP 0.77 BHP Standard CFM 5221 CFM Fan motor kW 0.58 kW Actual max CFMIft 1.41 CFMVft Fan static 0.50 inwg Outdoor Ventilation Air Data Design airflow CFM 708 CFM CFM/person 15.48 CFM/person CFM/ft 0.19 CFMVft Zone Sizing Summary for BLOCK LOAD Air Sizing Zone Zone Space System Information Air System Name blockload Number of zones 1 Equipment Class UNDEF Floor Area 3766.0 ft Air System Type VAV Location Seattle IAP, Washington Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Sizing Data ROOM PURPOSE Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft Zone CFM /ft Zone 1 67.7 5307 708 Jan 1900 0.0 3766.0 1.41 Terminal Sizing Data 506 Zone Name Reheat Coil Load (MBH) Reheat Coil Water gpm c@ 20.0 °F Zone Htg Coil Load (MBH) Zone Htg Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 7.5 0.75 0.0 0.00 1 Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft Space CFM/ft Air System Name VAV Number of zones 3 Zone 1 Equipment Class UNDEF Floor Area 3766.0 ft 9.9 Air System Type VAV Location Seattle IAP, Washington 1,2,3,4 Sizing Calculation Information CARRIER_ 45J Zone and Space Sizing Method: 8 Fitting Rooms 1 4.3 Jan 1900 340 0.0 506.0 0.67 1.5 Manager's Office 1 7.0 Jan 1900 550 0.0 92.0 5.98 Restrooms 1 1.3 Jan 1900 99 0.0 301.0 0.33 Floor Sales 1 1 15.1 Jan 1900 1185 0.0 890.0 1.33 Peak Sales 2 1 9.4 Jan 1900 734 0.0 490.0 1.50 (CFM) Sales 3 1 9.3 Jan 1900 732 0.0 484.0 1.51 1919 Sales 4 1 8.6 Jan 1900 673 0.0 497.0 1.35 Zone 2 Stockroom 1 12.7 Jan 1900 994 0.0 506.0 1.96 Air System Design Load Summary for BLOCK LOAD 7.0 550 14 Jan 1900 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB/ WB 84.5 °F/64.8 °F HEATING DATA AT DES HTG HEATING OA DB /WB 23.0 °F /19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU /hr) Latent (BTU/hr) Wndav & Skylight Solar Loads 0 if 0 - 0 fiz - - Wall Transrrission 0 ftz 0 - 0 ff 0 - Roof Transrrission 0 ff 0 - 0 ff 0 - Wndcw Transmission 0 if 0 - 0 ff 0 - Skylight Transmission 0 ft 0 - 0 ffz 0 - Door Loads 0 ff 0 - 0 ff 0 - Floor Transmission 3766 if 0 2.9 3766 ftz 0 - Partitions Off 0 - 0 fiz 0 - Ceiling 0 fP 0 - 0 ff 0 - Overhead Lighting 0 W 0 - 0 0 - Task Lighting 9648 W 28875 - 0 0 - Bectric Equipment 2258 W 7705 - 0 0 - Peaple 46 8582 9151 0 0 0 Infiltration - 0 0 - 0 0 MGscellaneous - 7700 0 - 0 0 Safety Factor 25% / 0% 13216 0 0% 0 0 » Total Zone Loads - 66078 9151 - 0 0 Zone Conditioning - 65870 9151 - -5 0 Renum Wall Load 0% 0 - 0 0 - Renum Roof Load 0% 0 - 0 0 - Flenum Lighting Load 0% 0 - 0 0 - Return Fan Load 5125 CFM 0 - 708 CFM 0 - Ventilation Load 684 CFM 10433 -4174 95 CFM 4510 0 Supply Fan Load 5125 CFM 1906 - 708 CFM -571 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 78209 4977 - 3934 0 Central Cooling Coil - 78209 4979 1.35 -3512 0 Terminal Reheat Coils - 0 - - 7446 - » Total Conditioning - 78209 4979 - 3934 0 Key: Positive values are clg loads Negative values are htg Toads Posthe values are htg loads Negative values are clg loads Air System Sizing Summary for FPB -1,2,3 City Name Seattle IAP Location Washington Latitude 47.5 Deg. Longitude 122.3 Deg. Elevation 449.0 ft Summer Design Dry-Bulb 85.0 °F Summer Coincident Wet -Bulb 65.0 °F Summer Daily Range 18.3 °F Winter Design Dry-Bulb 23.0 °F Winter Design Wet -Bulb 19.2 °F Atmospheric Clearness Number 1.05 Average Ground Reflectance 0.20 Soil Conductivity 0.800 BTU /(hr- ft - °F) Local Time Zone (GMT +1- N hours) 8,0 hours Consider Daylight Savings Time No Simulation Weather Data none N/A Current Data is 2001 ASHRAE Handbook Design Cooling Months January to December Air System Information Air System Name VAV Number of zones 3 Equipment Class UNDEF Floor Area 3766.0 if Air System Type VAV Location Seattle IAP, Washington Sizing Calculation Information Zone and Space Sizing Method: MODEL Zone CFM Peak zone sensible bad Calculation Months Jan to Dec ROOM PURPOSE Space CFM Coincident space loads Sizing Data Calculated ASHRAE 62 - OUTSIDE AIR REQUIREMENTS Central Cooling Coil Sizing Data SYSTEM NUMBER Total coil bad 6.9 Tons Load occurs at Jul 1600 REMARKS Total coil load 83.2 MBH OA DB / WB 84.5 / 64.8 °F (CFM /SF) Sensible coil load 78.2 MBH Entering DB / WB 72.0 / 62.3 °F SALES Coil CFM at Jul 1600 5124 CFM Leaving DB / WB 57.6 / 56.7 °F 0.20 Max block CFM at Jan 1900 5307 CFM Coil ADP 56.1 ° F FPB-1 Sum of peak zone CFM 5307 CFM Bypass Factor 0.100 OA BY LL SUPPLY AIR Sensible heat ratio 0.940 Resulting RH 64 % 506 ft 543.4 Design supply temp. 58.0 °F 101 BTU /(hr -ft 22.1 Zone T -stat Check 3 of 3 OK 419 Water flay @ 10.0 °F rise 16.64 gpm Max zone temperature deviation 0.0 °F NON -SALES Supply Fan Sizing Data 0.15 Actual max CFM at Jan 1900 5307 CFM Fan motor BHP 0.77 BHP FPB -3 Standard CFM 5221 CFM Fan motor kW 0.58 kW OA BY LL SUPPLY AIR Actual max CFM/ft 1.41 CFM/ft Fan static 0.50 inwg TOTAL 709 Outdoor Ventilation Air Data 14 Design airflow CFM 708 CFM CFMVperson 15.48 CFM/person CFM/ft 0.19 CFM 2369 Air System Information 480/3/60 Air System Name VAV Number of zones 3 0.75 Equipment Class UNDEF Floor Area 3766.0 ft 9.9 Air System Type VAV Location Seattle IAP, Washington 1,2,3,4 Sizing Calculation Information CARRIER_ 45J Zone and Space Sizing Method: 8 Zone CFM Peak zone sensible Toad Calculation Months Jan to Dec 14 Space CFM Coincident space loads Sizing Data Calculated 1 Zone Sizing Data 0.65 1/4 1.5 277/1/60 Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (MBH) (CFM) (CFM) Load (MBH) (ft CFM/ft Zone 1 24.5 1919 276 Jan 1900 0.0 1380.0 1.39 Zone 2 36.2 2838 419 Jan 1900 0.0 2294.0 1.24 Zone 3 7.0 550 14 Jan 1900 0.0 92.0 5.98 Zone Terminal Sizing Data Reheat Zone Zone Reheat Coil Htg Htg Mixing Coil Water Coil Water Box Fan Load gpm Load gpm Airflow Zone Name (MBH) @ 20.0 °F (MBH) @ 20.0 °F (CFM) Zone 1 2.9 0.29 0.0 0.00 1 Zone 2 4.5 0.45 0.0 0.00 1 Zone 3 0.1 0.01 0.0 0.00 1 Space Loads and Airflows Cooling lime Air Heating Floor Zone Name / Sensible of Flow Load Area Space Space Name Mult. (MBH) Load (CFM) (MBH) (ft CFM/ft Zone 1 Sales 1 1 15.1 Jan 1900 1185 0.0 890.0 1.33 Sales 2 1 9.4 Jan 1900 734 0.0 490.0 1.50 Zone 2 Fitting Rooms 1 4.3 Jan 1900 340 0.0 506.0 0.67 Restrooms 1 1.3 Jan 1900 99 0.0 301.0 0.33 Sales 3 1 9.3 Jan 1900 732 0.0 484.0 1.51 Sales 4 1 8.6 Jan 1900 673 0.0 497.0 1.35 Stockroom 1 12.7 Jan 1900 994 0.0 506.0 1.96 Zone 3 Manager's Office 1 7.0 Jan 1900 550 0.0 92.0 5.98 Design Weather Parameters City Name Seattle IAP Location Washington Latitude 47.5 Deg. Longitude 122.3 Deg. Elevation 449.0 ft Summer Design Dry-Bulb 85.0 °F Summer Coincident Wet -Bulb 65.0 °F Summer Daily Range 18.3 °F Winter Design Dry-Bulb 23.0 °F Winter Design Wet -Bulb 19.2 °F Atmospheric Clearness Number 1.05 Average Ground Reflectance 0.20 Soil Conductivity 0.800 BTU /(hr- ft - °F) Local Time Zone (GMT +1- N hours) 8,0 hours Consider Daylight Savings Time No Simulation Weather Data none N/A Current Data is 2001 ASHRAE Handbook Design Cooling Months January to December OUTSIDE AIR REQUIREMENTS MODEL UNIT SIZE ROOM PURPOSE GROSS FLOOR AREA (SQ. FT.) ASHRAE 62 - OUTSIDE AIR REQUIREMENTS MIN. FAN AIR (CFM) SYSTEM NUMBER ACTUAL OUTSIDE AIR (CFM) REMARKS INPUT kW (CFM /SF) (CFM) SALES 2,361 0.20 472 FPB-1 276 OA BY LL SUPPLY AIR FITTING RMS 506 0.20 101 FPB -2 419 OA BY LL SUPPLY AIR NON -SALES 899 0.15 135 FPB -3 14 OA BY LL SUPPLY AIR TOTAL 708 TOTAL 709 6 FAN POWERED VAV BOX SCHEDULE MARK MANUF. MODEL UNIT SIZE INLET SIZE PRIMARY AIR (CFM) MIN. PRIMARY AIR (CFM) MIN. FAN AIR (CFM) HEATER FAN REMARKS INPUT kW V /PH /HZ STAGES S.P. (IN. W.G.) HP FLA V /PH /HZ FPB -1 CARRIER - 45J 6 12 1919 276 1919 5.5 480/3/60 2 0.55 3/4 4.4 277/1/60 1,2,3,4 FPB -2 CARRIER 45J 6 14 2369 500 2369 8 480/3/60 2 0.75 2 -3/4 9.9 277/1/60 1,2,3,4 FPB -3 CARRIER_ 45J 3 8 550 14 550 1 277/1/60 1 0.65 1/4 1.5 277/1/60 1,2,3,4 _ REMARKS: 1. MANUFACTURED BY CARRIER. 2. PROVIDE 45JA -2212 CONTROL PACKAGE COMPLETE WITH THERMOSTAT AND TRANSFORMER. 3. PROVIDE INTEGRAL DISCONNECT SWITCH. 4. CONTRACTOR SHALL FURNISH AND INSTALL THREE (3) SETS OF STANDARD 1" AIR FILTERS. CONTRACTOR TO REPLACE FILTERS JUST PRIOR TO AIR BALANCING AND ONCE AGAIN AFTER FINAL STORE CLEANING IS COMPLETE. HVAC Equipment Schedule Manufacturer: Carrier RECEIVED CITY OF ` .'w!LA FEB 1 9 2008 PLHMi F GEN fER NEW STORE SHEET NUMBER: M2 -0 BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: MEM Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 BORES o2 / a (./Zp/ C) 1 Firm Registration No. 2002 ARCHITECT INFO: M McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 1 4 1 5. 2 8 8. 8 1 5 0 f . 4 1 5. 2 8 8. 8 1 8 1 www.mccalldesig n.com ISSUE TYPE: PERMIT /BID 12/21 /07 ISSUE SCALE: NOT TO SCALE DRAWN BY: MM JOB NO.: 207338 SHEET TITLE: MECHANICAL SCHEDULES AIR DISTRIBUTION DEVICE SCHEDULE MARK MANUFACTURER MODEL TYPE NECK SIZE (L" X W") FACE SIZE (L" X W") FRAME TYPE FINISH MATERIAL ACCESSORIES REMARKS SD -1 (1) (1) PERFORATED FACE 16" 24 X 24 (1) (1) STEEL PFS, DMPR 0.625 SD -2 (1) (1) PERFORATED FACE 12" 24 X 24 (1) (1) STEEL PFS, DMPR SD -3 (1) (1) PERFORATED FACE 6" 16 X 16 (1) (1) STEEL PFS, DMPR SD-4 (1) (1) PERFORATED FACE 6" 12 X 12 (1) (1) STEEL PFS, DMPR SR -1 LINDAB RGS -3 DUCT SUPPLY GRILLE -- 25 X 3 DUCT GALVANIZED STEEL EXT NO EXCEPTIONS ALLOWED RD -1 (4) (4) PERFORATED FACE N/A 24 X 24 (4) (4) STEEL PFS, DMPR RD -2 (5) (5) PERFORATED FACE 12 X 12 24 X 24 (5) (5) STEEL PFS RD -3 (4) (4) PERFORATED FACE N/A 16 X 16 (4) (4) STEEL PFS, DMPR RG -1 (6) (6) WALL TRANSFER GRILLE N/A VARIES (6) (6) STEEL — TG-2 (7) (7) PERFORATED FACE 12 X 12 24 X 24 (7) (7) STEEL PFS ACCESSORIES: PFS — PLASTER FRAME DMPR — DAMPER EXT— LINDAB AIR EXTRACTOR KEY NOTE MANUFACTURER MODEL FRAME TYPE ACCESSORIES FINISH (WHITE) REMARKS DAMPER PLASTER FRAME (1) KRUEGER 6504 23 PRN -100 5HCF23 BRITISH WHITE FOUR WAY BLOW PATTERN PRICE PDC-4 3 VCR -7 PFS B12 TITUS PCS -4 3 AG -75 TRM 26 (4) KRUEGER 6790 (NON DUCTED RETURN) 23 OBD 5HCF23 BRITISH WHITE PRICE PDDR (NON DUCTED RETURN) 3 VCS -3 PFS B12 TITUS PAR (NON DUCTED RETURN) 3 AG -95 TRM 26 (5) KRUEGER 6290 (DUCTED RETURN) 23 — 5HCF23 BRITISH WHITE PRICE PDDR (DUCTED RETURN) 3 — PFS B12 TITUS PAR (DUCTED RETURN) 3 — TRM 26 (6) KRUEGER S85 SURFACE — — BRITISH WHITE PRICE 535 SURFACE -- — B12 TITUS 25RL SURFACE — — 26 (7) KRUEGER 6290 (DUCTED TRANSFER) 23 — 5HCF23 BRITISH WHITE PRICE PDDR (DUCTED TRANSFER) 3 — PFS 812 TITUS PAR (DUCTED TRANSFER) 3 — TRM 26 FAN SCHEDULE MARK MANUFACTURER MODEL CFM S.P. (IN. W.G.) ELECTRICAL REMARKS H.P. V /PH /HZ EF -1 LOREN COOK GC -164 140 0.625 145 WATTS 120/1/60 1 EF -2 LOREN COOK GC -164 140 0.625 145 WATTS 120/1/60 1 Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 20 9563 PROFESSION Firm :4 S y a �� ti 38146 ..- I r °r wY' P: Fy [EXPIRES Z/670 1 Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t.415.288.8150 f.415.288.8181 www.mccalldesign.coni REMARKS: 1. PROVIDE WITH FACTORY MOUNTED DISCONNECT SWITCH AND BACKDRAFT DAMPER 1 NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15 /07 OPENING 2008 CONSULTANT INFO: mm Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 20 9563 PROFESSION Firm :4 S y a �� ti 38146 ..- I r °r wY' P: Fy [EXPIRES Z/670 1 Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t.415.288.8150 f.415.288.8181 www.mccalldesign.coni ISSUE TYPE: LL /PERMIT /BID 12/21/07 ISSUE SCALE: NOT TO SCALE DRAWN BY: PJRIWKK JOB NO.: 207338 SHEET TITLE: MECHANICAL SCHEDULES SHEET NUMBER: M2 -Oa RECEIVED crr9' OF T;_IICVVfLA DEC 2 7 2007( ��r� l Tc N1 1 MINIMUM 36" ' 22 5 TYPICAL CLEARANCE ( ) �� PER N.E.C. ,� a BEND ADJUST 5FT MAX. a NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 ELECTRIC HEATER CONTROL CABINET _Ai. INSULATED TO S.A. ROUND DUCT MAIN BEFORE FLEXIBLE CONNECTORS CONNECT DUCT (PER OF NOT A DUCT IS TERMINAL PROVIDE STRAIGHT CONTROL ENCLOSURE. CLEARANCE TO V PERMIT ACCESS TO CONTROLS. � 1 0 PRIMARY AIR FLOW l ik: , !41)) ' % FILTER DISPOSABLE PRIMARY LOW OR PLAN). FLEXIBLE EXCEED REDUCER SHOWN UNIT MIN. DUCT --21 I I r` RACK PRESSURE SPIRAL EXTENDED 1' LARGER CONNECTION 4 DIAMETERS UPSTREAM TYPE AIR SEAM DUCT -0 WHERE .I • FOR INLET. SHALL ". I� \ � 1" FILTERS FLEXIBLE DUCT LENGTH PROVIDE TRUNK THAN SIZE. OF OF INLET. TAPE &STRAP FLEXIBLE DUCTWORK CONNECTION (TYPICAL) PLACE DUCT HANGER STRAP INSULATED FLEXIBLE DUCTWORK LENGTH STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 1 RADIAL DAMPER - PROVIDE MIN. ONE DUCT DIAMETER TO DIFFUSER I I ___..._.__..�_ -_ ' ■ l � . SUPPLY DIFFUSER WITH LAY -IN PROVIDE STEEL FRAMING FRAME AND ACCESSORY STEEL MOUNT AROUND OPENING AND ADAPTOR FRAME FOR GYP. BOARD SECURE CEILING TO STRUCTURE. GYPSUM BOARD CEILING GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 1 300 TO SCALE DIFFUSER MOUNTING DETAIL N TO SCALE FAN POWERED VAV BOX DETAIL DUCT MOUNTED SMOKE DETECTOR & 120 V. ELECT. ACTUATOR FURN DAMPER ASSEMBLY SHALL BE RUSKIN AND SHALL BE U.L. 555S CLASSIFIED. FOR DYNAMIC OPERATION. AIR FLOW —i,—•-•,-,.. n. ._, / ,; ,//7 / " A MOUNTSLEEVE IN SLEEVE TO BE OF EXTRACTOR M SOU T NTED SUPPLY DIFFUSER 1= - _ \\\\ 1 1 1 1 1 f/..4 a � V� OFFICE /RESTROOM WALL -0" A.F.F. 13' -0" TO 15'- 9 "A.F.F. AND 1/3 OF LEFT. OF HORIZONTAL DEGREES DOWN. OF HORIZONTAL DEGREES DOWN. DUCT GAUGE AS REC. BY MANUFACTURER FOR U.L. APPROVAL. PLAN SPIRAL MAIN DUCT © 16' © SECTION `, DUCT SINGLE BLADE FOR ROUND DUCTS AND MULTIPLE BLADES FOR RECTANGULAR DUCTS. ATTACH DAMPER TO SLEEVE AS REQUIRED BY CONSULTANT INFO: e Mill Consulting Engineers �� Energy Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project J # 2079563 F TYPICAL CONNECTION �1 ADJUST THROW OF VERTICAL BLADES FOR 1/3 OF AIR STRAIGHT AIR TO 45 DEGREES RIGHT AND 1/3 OF AIR TO 45 DEGREES Q FOR SUPPLY REGISTERS 13' -0" TO 15' -9 ", ADJUST THROW BLADES FOR 1/3 OF AIR STRAIGHT AND 2/3 OF AIR TO 22.5 Q FOR SUPPLY REGISTERS 16 ' -0 & HIGHER, ADJUST THROW BLADES FOR 1/2 OF AIR STRAIGHT AND 1/2 OF AIR TO 22.5 \ �\ SETAINING MANUFACTURER. ANGLE. ��. WALL OR FLOOR -���� \� CONSTRUCTION H VARIES. NOTES: 1. DAMPER MUST BE SUPPORTED IN WALL ANGLES. DAMPER MUST REMAIN IN PLACE IF DUCT SIZE AS RECOMENDED BY MANUFACTURER ( BY SLEEVE AND RETAINING COLLAPSES. PROFESSI0 c AL ST: MP { f '.'�:�%' ; y 1 3 8141; � , . f$ y FIRE SMOKE DAMPER DETAIL NOT TO SCALE DUCT MOUNTED REGISTER DETAIL NOT TO SCALE 303 1a1 I� = f : ... s A € _ __ , ' 12 "X 12" `` ' ,. q I EXPIRES Z /0t 1 Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 551 Kearny Street Suite 710 San FranyTSaa cn 94110 1.415.288.8150 f. 4 1 5.2 8 8.8 1 8 1 w ww.mccandesign.com AIR DUCT RETURN (RD -2) OR TRANSFER (TG -2) GRILLE WITH LAY -IN FRAME AND ACCESSORY STEEL -.-_- . ----- _; .,.- _...._- ' ' - WIRE MESH SCREEN (WMS) RETURN GRILLE RG -1 ( ) 1 MOUNT ADAPTOR FRAME METAL STUD FOR GYP. BOARD — CEILING --- .__.... (�• . ' SUPPORT OR FRAMED WALL ISSUE TYPE: LL /PERMIT /BID 12/21 /07 ISSUE _ CEILING LINE _ _ -_i f _ -� _ �.; _y;T -- PROVIDE STEEL FRAMING L ._- =� SCALE: AS NOTED AROUND OPENING AND SECURE TO STRUCTURE. OFFICE/ RESTROOMS �. �� ii If I -t f..�j. *-' ) �- `'�... > OFFICE /RESTROOM WALL STOCK/ VESTIBULE AEC men C 0P -n► : ►LA DRAWN BY: PJR/WKK JOB NO.: 207338 SHEET TITLE: MECHANICAL DETAILS / � %ll %/1/77/'7 2 7 20071 SHEET NUMBER: m2.1 TRANSFER AND RETURN AIR GRILLE DETAIL NOT TO SCALE PLUMBING SCHEDULE 1 MARK DESCRIPTION FIXTURE VALVE/FAUCET CONNECTIONS VOLTAGE PHASE WATTS I REMARKS MFR MODEL MFR MODEL WASTE VENT CW HW WC-1 WATER CLOSET HANDICAP AMERICAN STANDARD CADET #2377.100, WHITE - - 4" 2" 3/4" - - - - 1, 7 (. 1 nl IT LAV LAVATORY KOHLER K -2035 AMERICAN STANDARD MONTEREY #6530.170 1 -1/2" 1 -1/2" 1/2" 1/2" - - - L2 t.-.4- EWH WATER HEATER TANK BRADFORD WHITE M- 1 -6U6SS 6- GALLON - - - - 3/4" 3/4" 120 1 1500 - EWC ELECTRIC WATER COOLER ELKAY EZTLBC TWO LEVEL - - 1 -1/2" 1 -1/2" 1/2" - 120 1 325 4 MS MOP SINK FIAT PRODUCTS #MSB -2424 AMERICAN STANDARD UTILITY #8344.112.004 3" 1 -1/2" 3/4" 3/4" - - - 5 FD FLOOR DRAIN J.R. SMITH 2005A -P050 - - 3" 1 -1/2" - - - - - 6 TP TRAP PRIMER PRECISION PLUMBING PRIME -RITE - - - - 1/2" - - - - - WCO WALL CLEAN OUT - - - - - - - - 3 WHA WATER HAMMER ARRESTERS ZURN SHOCKTROL - - - - - - - - - - ET EXPANSION TANK WATTS PET -5 2- GALLON - - - - 3/4" - - - - - AP WALL ACCESS PANEL ZURN FAUCET ZANB- 1460 -11 11" x 11" - - - - - - - - - REMARKS: 1 PROVIDE WITH BEMIS MANUFACTURING WHITE OPEN FRONT SEAT LESS COVER #1955SSC. 2 PROVIDE WITH PLUMBEREX MODEL PROEXTREME MODEL #X4111 AND X4112 FOR TRAP AND SUPPLY PROTECTION. 3 CAST IRON CLEANOUT TEE WITH BRONZE THREADED CLEANOUT PLUG. PLUG TO BE GAS AND WATER TIGHT. 4 PROVIDE WITH DEARBORN 17GA. TRAP, TRAP ADAPTER AND ANGLE STOP. 5 PROVIDE WITH FIAT PRODUCTS VINYL BUMPERGAURD #E- 77 -AA. 6 FLOOR DRAIN TO BE PROVIDED WITH TRAP PRIMER CONNECTION. 7 PRESSURE ASSISTED TANK -TYPE. RESPONSIBILITY MATRIX LEGEND QTY STOREFRONT EXTRUSION L 0 FACTORY FINISHED I 'LI L = LANDLORD T FURNISHED BY 5 4 8 ITEM 0 = OWNER (GAP INC.) COMMENTS I GC= GENERAL CONTRACTOR 1 2 MS 1 INSTALLED BY 3 3 RESPONSIBILITY MATRIX EWC WATER LINE TO LEASE SPACE L L .5 SEWER LINE TO LEASE SPACE L L 11 14 I REMARKS: NOTE: THE RESPONSIBILITY MATRIX ONLY DELINEATES ITEMS SUPPLIED AND /OR INSTALLED BY OWNER AND / OR LANDLORD. ANY WORK BY CONSTRUCTION DOCUMENTS NOT DEFINED AS RESPONSIBILITY OF OWNER OR LANDLORD IS SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. SEE BID CLARIFICATION LETTER FOR ANY VARIATION BY SCOPE OF WORK RESPONSIBILITY. FIXTURE QTY SUPPLY UNITS SUPPLY TOTAL FU WASTE UNITS WASTE TOTAL FU WC--1 2 2.5 5 4 8 LAV 2 1 2 1 2 MS 1 3 3 3 3 EWC 2 .5 1 .5 1 TOTALS 11 14 PLUMBING CODED NOTES CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE AS SHOWN. FIELD VERIFY EXACT LOCATION AND DIRECTION OF FLOW OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEANOUT AT CONNECTION TO LANDLORD'S MAIN AND COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR FINISH WITH G.C. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. EXTEND NEW VENT TO EXISTING LANDLORD SUPPLIED TIE -IN POINT. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. CONNECT NEW COLD WATER LINE INTO THE EXISTING COLD WATER TAP. NOTIFY G.C. IF TAP IS SMALLER THAN SHOWN. REFER TO COLD WATER AND HOT WATER RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. FIELD VERIFY EXACT LOCATION OF EXISTING TAP PRIOR TO BID. INSTALL 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION WITH ACCESS PANEL INSTALL DRAWING TUBE HOLDER FOR STORAGE OF ALL CONTRACTORS "AS- BUILT" DRAWINGS. PLACE AS- BUILT" PLUMBING DRAWINGS IN TUBE. 200) PROVIDE AND INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER WITHIN THE SPACE PRIOR TO MAKING ANY OTHER CONNECTIONS TO THE WATER SERVICE PIPING. GENERAL NOTES 1. TENANTS CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS. 2. TENANT'S CONTRACTOR IS TO VERIFY LOCATION; GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH WESTFIELD'S ON -SITE TENANT COORDINATORS BEFORE PROCEEDING WITH WORK. 3. TENANT'S CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE EVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. 4. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. PLUMBING GENERAL NOTES 1. THE ABBREVIATION G.C., WHEREVER IT APPEARS IN THESE PLUMBING DRAWINGS, SHALL REFER TO THE GENERAL CONTRACTOR. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUB - CONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE PLUMBING SYSTEMS SHALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR. COORDINATE ROOF PENETRATIONS WITH LANDLORD AND G.C. 4. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 5. ALL SHUT -OFF VALVES LOCATED IN AREAS WITH HARD CEILINGS SHALL HAVE ACCESS PANELS INSTALLED. COORDINATE LOCATION AND TYPE WITH G.C. AND ARCHITECT. 6. CONTRACTOR TO VERIFY THAT ALL ITEMS ON CONTRACTOR CHECKLIST ARE COMPLETED PRIOR TO MEP COMMISSIONING. CONTRACTOR WILL RECEIVE CONTRACTOR CHECKLIST IN ELECTRONIC FORM WITH BID DOCUMENTS. PLUMBING SYMBOLS LEGEND F G D -0V 1`7 tta AFF /AFG VTR CO BFP FCO WCO WHA TP COLD WATER (CW) FIRE PROTECTION (F) (SPRINKLER /STANDPIPE) HOT WATER (HW) GAS LINE (G) CONDENSATE LINE (D) PLUMBING VENT (V) SANITARY WASTE (SAN) BELOW SLAB /GRADE PIPE TURNING UP /DOWN TEE TURNING UP /DOWN SHUTOFF VALVE (BALL TYPE) CHECK VALVE REDUCER ABOVE FINISHED FLOOR /GRADE VENT THRU ROOF CLEANOUT BACKFLOW PREVENTER CONNECT TO EXISTING FLOOR CLEAN OUT FLOOR DRAIN WALL CLEAN OUT WATER HAMMER ARRESTOR TRAP PRIMER try F_ . RECEIVED CITY U °/�JILA FEB 1 9 2008 i'EHfr';1 f CL NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 05/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: O � Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESS! [EXPIRES o2,(oy2)to Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Keamy Sheet Suite 710 San Francisco CA 94108 t. 4 1 5. 2 8 8. 8 1 5 0 1.415.288.8181 www. mcca Ildesign.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: AS NOTED DRAWN BY: DKZ/WKK JOB NO.: 207338 SHEET TITLE: PLUMBING PLAN AND SCHEDULES SHEET NUMBER: M3-O . ' >:f O M fl: '. , T:I 1 'i� = r� , 1 t 4 "SAN '.1_ -.f -._ f- TTm 4 "SAN 0 HT ROOM —_ . ___.__.__ ` n n I o o J j FD 103 LAV FD 103 4 "SAN WC 2"V I I \ \J ) -1 ‘ l I �� ) ik--1 2 "SAN :. LAV 3/4" 3 /4 "HW W 7 -- f _ -I ) I 1 /2 "CWT Li X ■ I WCO EWC I ... �\ ' in\ ' _:- .. -.::.1 1 k — — — M 1 / 1 _ _ L _ " .._ 100 '" __. � - __ 101 3 "SAN V � _ _ _ _ _ 100 `� 3 /4 "CW - 3 /4 "HW ? ')I1,1 , ' 0 1 -1/2" -H , it 102 wco I 300 _) ._ rotes EWH c )iIl MS 1RPZ 200 REFER TO RISER DIAGRAMS ON .� SHEET M3 -1 FOR ADDITIONAL PIPE SIZES NOT SHOWN Mil ENLARGED PLUMBING PLAN - RESTROOMS 1/4" = 1' -0" 101 1 T iL 100 101 101 SALES AREA SALES ARE ' WNW M3 - 0 o :'(lfifyPJ' MLN �.} FITIIWG ROOM ROOM ;1GR S i , ; AIFS ALA 1 OI.L i PD TOILET ROOf�i E ARE,", Gf f lC r _ I 1 ( -� _. _� ID:r7=i I � 1 [r I V M1 I .. ...... LAt AREA I • HALLWAY , . - I ENTRY 4 SAN - -- SJC?;I<ft.Q J . � . I 102 -1 3 /4''CW 104 ` 1 1J I - -: 200 100 101 102 7 1::' r.. l -:_ -- f n A DISPLAY AREA 2 =43 = 1' -0" OVERALL PLUMBING PLAN 1/ PLUMBING CODED NOTES CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE AS SHOWN. FIELD VERIFY EXACT LOCATION AND DIRECTION OF FLOW OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEANOUT AT CONNECTION TO LANDLORD'S MAIN AND COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR FINISH WITH G.C. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. EXTEND NEW VENT TO EXISTING LANDLORD SUPPLIED TIE -IN POINT. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. CONNECT NEW COLD WATER LINE INTO THE EXISTING COLD WATER TAP. NOTIFY G.C. IF TAP IS SMALLER THAN SHOWN. REFER TO COLD WATER AND HOT WATER RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. FIELD VERIFY EXACT LOCATION OF EXISTING TAP PRIOR TO BID. INSTALL 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION WITH ACCESS PANEL INSTALL DRAWING TUBE HOLDER FOR STORAGE OF ALL CONTRACTORS "AS- BUILT" DRAWINGS. PLACE AS- BUILT" PLUMBING DRAWINGS IN TUBE. 200) PROVIDE AND INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER WITHIN THE SPACE PRIOR TO MAKING ANY OTHER CONNECTIONS TO THE WATER SERVICE PIPING. GENERAL NOTES 1. TENANTS CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS. 2. TENANT'S CONTRACTOR IS TO VERIFY LOCATION; GET APPROVAL AND REQUIREMENTS FOR ALL TRENCHING WITH WESTFIELD'S ON -SITE TENANT COORDINATORS BEFORE PROCEEDING WITH WORK. 3. TENANT'S CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE EVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. 4. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. PLUMBING GENERAL NOTES 1. THE ABBREVIATION G.C., WHEREVER IT APPEARS IN THESE PLUMBING DRAWINGS, SHALL REFER TO THE GENERAL CONTRACTOR. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUB - CONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE PLUMBING SYSTEMS SHALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR. COORDINATE ROOF PENETRATIONS WITH LANDLORD AND G.C. 4. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 5. ALL SHUT -OFF VALVES LOCATED IN AREAS WITH HARD CEILINGS SHALL HAVE ACCESS PANELS INSTALLED. COORDINATE LOCATION AND TYPE WITH G.C. AND ARCHITECT. 6. CONTRACTOR TO VERIFY THAT ALL ITEMS ON CONTRACTOR CHECKLIST ARE COMPLETED PRIOR TO MEP COMMISSIONING. CONTRACTOR WILL RECEIVE CONTRACTOR CHECKLIST IN ELECTRONIC FORM WITH BID DOCUMENTS. PLUMBING SYMBOLS LEGEND F G D -0V 1`7 tta AFF /AFG VTR CO BFP FCO WCO WHA TP COLD WATER (CW) FIRE PROTECTION (F) (SPRINKLER /STANDPIPE) HOT WATER (HW) GAS LINE (G) CONDENSATE LINE (D) PLUMBING VENT (V) SANITARY WASTE (SAN) BELOW SLAB /GRADE PIPE TURNING UP /DOWN TEE TURNING UP /DOWN SHUTOFF VALVE (BALL TYPE) CHECK VALVE REDUCER ABOVE FINISHED FLOOR /GRADE VENT THRU ROOF CLEANOUT BACKFLOW PREVENTER CONNECT TO EXISTING FLOOR CLEAN OUT FLOOR DRAIN WALL CLEAN OUT WATER HAMMER ARRESTOR TRAP PRIMER try F_ . RECEIVED CITY U °/�JILA FEB 1 9 2008 i'EHfr';1 f CL NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 05/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: O � Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESS! [EXPIRES o2,(oy2)to Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Keamy Sheet Suite 710 San Francisco CA 94108 t. 4 1 5. 2 8 8. 8 1 5 0 1.415.288.8181 www. mcca Ildesign.com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: AS NOTED DRAWN BY: DKZ/WKK JOB NO.: 207338 SHEET TITLE: PLUMBING PLAN AND SCHEDULES SHEET NUMBER: M3-O SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE. DRAIN VALVE J SHELF ABOVE MOP SINK CEILING TO BE MOUNTED ON THE WALL OR PLATFOR 1" RUN FULL SIZE TO MOP SINK TANK WATER HEATER INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS UNION (TYP.) 3/4" T & P RELIEF VALVE WATER HEATER SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. 2" WIDE, 20 GA. SHEET METAL BAND, SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE. GALV. DRIP PAN. PROVIDE 6 CLEARANCE BETWEEN WATER HEATER AND GALV. DRIP PAN ON ALL SIDES SEPARATE 1" DRAINS TO MOP SINK NOT TO SCALE WHA WHA 11 ND HOT WATER RISER DIAGRAM WHA WHA �• 1- 1/2" EWC r. i 1/4" DIAMETER THRU BOLT WITH TOGGLE (TYP. OF 2) PAN HEAD SCREWS TO SECURE STRAPS 3/4" X 2" POPULAR PLYWOOD TRIM SCREWED TO 2"X4" METAL STRAP (TYP. OF 2) SECTION NTS DRAWING TUBE LOOSE PVC TOP CAP THANK YOU. EXTENT OF WOOD HOLDER PVC BOTTOM CAP GLUED IN PLACE THIS TUBE CONTAINS STORE DRAWINGS AND IS NOT TO BE REMOVED WITHOUT THE CONSENT OF THE STORE MANAGER. 24" A.F.F. ELEVATION NTS NOT TO SCALE COLD WATER WASTE AND VENT RISER DIAGRAM NOT TO SCALE NOT TO SCALE STORE NO.: GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 CONSULTANT INFO: � v A Consulting Engineers Energy Engineering Associate$, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFES 10 Firm Registration No. 2002 - RECEIVED CITY OF TUKWILA FEB 19 2008 PEHMIT CENTER NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 DESIGN CHANGES REV. #1 02.06.08 ARCHITECT INFO: M McCall Design Group 550 Kearny Sheet Suite 710 San Francisco CA 94108 t. 4 1 5. 2 8 8. 8 1 5 0 f. 415- 288.8181 www. mccclldesign_com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: AS NOTED DRAWN BY: DKZ/WKK JOB NO.: 207338 SHEET TITLE: PLUMBING DETAILS AND RISERS SHEET NUMBER: M3 -1 SPRINKLER MAIN TO LEASE SPACE L L REMARKS BACK —FLOW PREVENTOR AND FLOW DETECTOR L L Q RECESSED HEAD A L = LANDLORD 0 = OWNER (GAP INC.) FURNISHED BY DESIGN CHANGES REV. #1 02.06.08 COMMENTS REMARKS: NOTE: THE RESPONSIBILITY MATRIX ONLY DELINEATES ITEMS SUPPLIED AND /OR INSTALLED BY OWNER AND / OR LANDLORD. ANY WORK BY CONSTRUCTION DOCUMENTS NOT DEFINED AS RESPONSIBILITY OF OWNER OR LANDLORD IS SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. SEE BID CLARIFICATION LETTER FOR ANY VARIATION BY SCOPE OF WORK RESPONSIBILITY. SPRINKLER HEAD LEGEND SYMBOL DESCRIPTION REMARKS • CONCEALED HEAD STORE NAME: SOUTHCENTER MALL Q RECESSED HEAD A L = LANDLORD 0 = OWNER (GAP INC.) FURNISHED BY DESIGN CHANGES REV. #1 02.06.08 COMMENTS ITEM RESPONSIBILITY MATRIX LEGEND STOREFRONT EXTRUSION L 0 FACTORY FINISHED STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 A L = LANDLORD 0 = OWNER (GAP INC.) FURNISHED BY DESIGN CHANGES REV. #1 02.06.08 COMMENTS ITEM — GC= GENERAL CONTRACTOR INSTALLED BY CONSULTANT INFO: MEN MUM k Consulting Engineers NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 DESIGN CHANGES REV. #1 02.06.08 CONSULTANT INFO: MEN MUM k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSI Firm INAL ST.' MP: c � y Registration No. 1 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 71 San Francisco CA 94108 1. 4 1 5. 2 8 8. 8 1 5 0 t. 4 1 5. 2 8 8. 8 1 8 1 www. mccalldeslgn_com ISSUE TYPE: PERMIT /BID 12/21/07 ISSUE SCALE: 1/8 " =1' -0" DRAWN BY: DKZ/WKK JOB NO.: 207338 SHEET TITLE: FIRE SPRINKLER PLAN LA I SHEET NUMBER: M4 -0 \ l I , A/ AY (.)(_ K P00M f FITTING ROOM MGR'S • SALE', 2 () <2a 0 if _ 1L.._'› • • • • SALES AREA 1 - • • • • DISPLAY ARE.A I ENTRY DISPLAY AREA 2 14) z 100 FIRE SPRINKLER PLAN 01/8 "• -0" 200 SPRINKLER GENERAL NOTES 1. THE ABBREVIATION GC, WHEREEVER IT APPEARS IN THESE MECHANICAL AND ELECTRICAL DRAWINGS, SHALL REFER TO THE GENERAL CONTRACTOR. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT I5 THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. FIRE PROTECTION PLANS, SPRINKLER DRAWINGS, MUST BE ENGINEERED AND WET SIGNED BY A LANDLORD APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL JURISDICTION. FINAL INSTALLATION MUST COMPLY WITH NFPA 13 AND STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 4. SPRINKLER HEAD LAYOUT IS A SUGGESTED LAYOUT. COORDINATE SPRINKLER HEAD LAYOUT AND PIPE ROUTING WITH ARCHITECTURAL PLANS, STRUCTURAL PLANS, HVAC CONTRACTOR, ELECTRICAL CONTRACTOR AND THE G.C. THIS CONTRACTOR SHALL INCLUDE IN THE BID AND BE RESPONSIBLE FOR EXACT QUANTITY OF SPRINKLER HEADS REQUIRED FOR COVERAGE AND FINAL APPROVAL. 5. LOCATE SPRINKLER MAIN AND RELATED SHUT OFF VALVES IN AN ACCESSIBLE LOCATION WITHIN THE STOCKROOM. 100 SPRINKLER CODED NOTES PLACE "AS– BUILT" SPRINKLER DRAWINGS IN DRAWING TUBE. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. ADJUST SPRINKLER HEADS REQUIRED BY NFPA13 TO AVOID DUCTWORK. COORDINATE INSTALLATIONS OF HEADS WITH HVAC CONTRACTOR AND G.C. CO DE .7;!'1':'h :i.) RESPONSIBILITY MATRIX RECENED CITY OF T.;;.<\—Al FEB 19 2008 PERMIT GENT NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: CJ 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP P R OJ. I . D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 CONSULTANT INFO: mom 1111111111 k Consulting En • sneers Rd Energy Engineering Associates, Inc. 6615 Vaught Ranch Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSI ` jy' ~.' 44 f = R 38146 J0<N,, s r i4 . [ EXPIRES Z c Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Kearny Street Suite 710 San Francisco CA 94108 t.415.288.8150 1.415.288.8181 www.mccalidesign.cam ISSUE TYPE: LL /PERMIT /BID 12/21/07 ISSUE SCALE: NOT TO SCALE DRAWN BY: DKZWKK JOB NO.: 207338 SHEET TITLE: MECHANICAL SPECIF ED..„ A IDEC 27 2007 ,i: SHEET NUMBER: M5 -0 B. GENERAL REQUIREMENTS DIVISION 15 - MECHANICAL SECTION 15000 BASIC MECHANICAL REQUIREMENTS A. NOTE 1. THE ABBREVIATION G.C. WHEREVER IT APPEARS IN THESE MECHANICAL DRAWINGS AND SPECIFICATIONS, SHALL REFER TO THE GENERAL CONTRACTOR. 2. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 3. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT 15 THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE THEIR SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS TO COMPLY WITH THE SCHEDULE AND THE PROJECT COMPLETION DATE. 5. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 6. REFER TO RESPONSIBILITY SCHEDULE ON THE MECHANICAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR OWNER SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE G.C. CONSTRUCTION MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH 15 USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING AND CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER 15 MORE STRINGENT. C. CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPUCABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE OWNER TO THE CONTRACTOR. D. LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK. 2. FURNISH TO THE G.C.'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT E. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. ANY PROPOSED SUBSTITUTIONS MUST BE PR- QUALIFIED, LISTED IN THIS CONTRACTOR'S BID AND HAVE A COST SAVINGS FOR THE OWNER OF AT LEAST $500 PER TYPE OF EQUIPMENT. ADDITIONALLY, ONLY MANUFACTURERS CONSIDERED AS AN EQUAL OR Bt►►LR IN ALL ASPECTS TO THAT SPECIFIED WILL BE REVIEWED. ALL SUBSTITUTIONS ARE SUBJECT TO APPROVAL IN WRITING, THROUGH SHOP DRAWINGS PROCESS, BY THE G.C.'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE OWNER RESERVES THE RIGHT TO REJECT ANY PROPOSED SUBSTITUTIONS. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 2. MECHANICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO THE G.C.'S CONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR THE CONSTRUCTION MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE G.C.'S OFFICE AND THE SUB - CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. F. GUARANTEE 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER THEIR CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY THE GENERAL CONTRACTOR'S CONSTRUCTION MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. THE OWNER SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY THE OWNER AND ITS VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID. G. RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE STAMPED "DO NOT REMOVE" AND PLACED IN DRAWING TUBE LOCATED NEXT TO THE ELECTRICAL PANELS. (SEE DRAWINGS FOR LOCATION.) H. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE G.C.'S CONSTRUCTION MANAGER, IN WRITING OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, THE G.C.'S CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. I. PHASING REQUIREMENTS 1. THIS CONTRACTOR I5 TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S HVAC, PLUMBING AND SPRINKLER SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE WITH THE G.C.'S CONSTRUCTION MANAGER AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE HVAC, PLUMBING OR FIRE PROTECTION SYSTEMS. J. DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE G.C.. COORDINATE WITH THE G.C. ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. EACH CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE G.C. FOR THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL /FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION WITH THE G.C. PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY THE G.C. K. SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. L. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6 LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. END OF SECTION 15000 A. SCOPE OF WORK E. TESTS AND ADJUSTMENTS. DIVISION 15 - MECHANICAL SECTION 15200 PLUMBING 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. B. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. C. FIXTURES AND EQUIPMENT AS SCHEDULED. D. COMPLETE NATURAL GAS PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. EQUIPMENT AND INSTALLATION 1. REFER TO PLANS FOR EQUIPMENT AND FIXTURE SCHEDULES. A. TRAP PRIMERS SHALL BE PRECISION PLUMBING "PRIME -RITE" OR EQUAL. B. WATER HAMMER ARRESTERS SHALL BE ZURN "SHOCKTROL" OR EQUAL. 2. SANITARY PIPING A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STEEL. ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER TRADES. B. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES OF TENANTS IN SPACES BELOW, WHEN APPLICABLE INSULATION TO BE AS SPECIFIED FOR WATER PIPING. 3. POTABLE WATER PIPING SHALL BE AS FOLLOWS: A. BELOW GRADE: TYPE 'K', ANNEALED TYPE TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER BRAZE ALL JOINTS. B. ALL OTHER: TYPE 'L' OR TYPE "M" (IF PERMITTED BY LANDLORD AND LOCAL CODE AUTHORITY) DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95 -5 TIN-ANTIMONY SOLDER 4. PIPING OF DISSIMILAR METALS MUST BE DI- ELECTRICALLY SEPARATED. 5. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY THE G.C.'S CONSTRUCTION MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERATIONS OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDING EQUIPMENT SUPPLIED. 6. INSULATE ALL HOT WATER AND COLD WATER PIPING WITH 1" THICK (K =0.23 ® 75 F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. 7. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH TRUEBRO MODEL 102W "HANDI LAV GUARD" INSULATION KIT. 8. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 9. STERIUZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. 10. CLEAN -OUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. FLOOR DRAINS SHALL BE ZURN Z -415 OR EQUAL WITH TRAP PRIMER CONNECTION. WALL COVERS ARE TO BE STAINLESS STEEL AND FLOOR COVERS ARE TO BE BRASS. PROVIDE FLOOR COVERS WITH INSET AREA FOR CARPETED LOCATIONS. ALL CLEAN -OUT LOCATIONS SHALL BE APPROVED BY THE G.C.'S CONSTRUCTION MANAGER. 11. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEIUNGS IN FINISHED AREAS. 12. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: A. TEST WATER PIPING AT 100 PSIG FOR SIX HOURS. B. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. 13. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE. 14. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. REFER TO PLANS TO DETERMINE IF WATER METER IS REQUIRED. C. GAS PIPING 1. FURNISH AND INSTALL A COMPLETE GAS PIPING SYSTEM IF APPUCABLE. REFER TO PLANS TO DETERMINE IF A GAS SYSTEM I5 REQUIRED. 2. GAS LINES SHALL BE BLACK STEEL, SCHEDULE 40, ASTM A -120, WITH MALLEABLE THREADED FITTINGS FOR 2" AND SMALLER, AND WITH WELDED JOINTS FOR 21/2" AND LARGER. 3. FURNISH AND INSTALL A GAS COCK, DIRT LEG, AND UNION CONNECTION TO SEAC1 - 4. PITCH PIPING AT A UNIFORM GRADE OF 1/4" IN 15 FEET UPWARD IN DIRECTION. -- --°- OF FLOW. SUPPORT PIPING EVERY 5 FEET. SUPPORT AS REQUIRED BY LANDLORD CRITERIA, AS DETAILED ON DRAWINGS, OR BY STANDARD INDUSTRY PRACTICE, WHICHEVER IS MORE STRINGENT. PIECE OF EQUIPMENT. 5. GAS PIPING EXPOSED ON ROOF MUST BE PAINTED WITH RUST- INHIBITING PAINT. 6. GAS PIPING INSTALLED IN RETURN AIR PLENUMS SHALL BE SLEEVED AND VENTED OR WELDED IN ACCORDANCE WITH THE LOCAL GAS COMPANY, LOCAL CODE, AND APPLICABLE NFPA 54 CODES. 7. TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NFPA 54 CODES. 8. CONTACT AND COORDINATE GAS SERVICE, METER AND REGULATOR REQUIREMENTS WITH THE LOCAL GAS COMPANY AND THE MALL'S OPERATIONS MANAGER PRIOR TO BID. INCLUDE INSTALLATION COST OF GAS METER AND REGULATOR IN BID. END OF SECTION 15200 A. SCOPE OF WORK 1. THIS CONTRACTOR MUST USE A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR TO PERFORM ALL FIRE PROTECTION WORK. ALL COSTS MUST BE INCLUDED IN THIS CONTRACTORS BID. FIRE PROTECTION CONTRACTOR MUST COMPLY WITH ALL SECTIONS OF THIS SPECIFICATION AND INCLUDE SAME IN BID. 2. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE WITH EXISTING CONDITIONS, NFPA -13, LOCAL CODES, LANDLORD'S CRITERIA, AND INSURANCE CARRIERS FOR THE MALL AND THE OWNER. DIVISION 15300- MECHANICAL SECTION 15300 FIRE PROTECTION B. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. C. DESIGN DRAWINGS, HYDRAULIC CALCULATIONS, SUBMITTALS AND APPROVALS. D. PERMITS, FEES, AND CHARGES. E. TESTS AND TEST CERTIFICATES. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. CONTRACTOR SHALL USE APPROVED INDUSTRY FIRE SPRINKLER STANDARDS FOR REUSING EXISTING FIRE SPRINKLER BRANCHES AND SUBMIT CALCULATIONS TO THE G.C.'S CONSTRUCTION MANAGER UPON REQUEST OR REWORK SYSTEM TO THE G.C. CONSTRUCTION MANAGER'S SATISFACTION. 4. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. CONFIRM REQUIREMENTS WITH THE G.C. PRIOR TO BID. B. SHOP DRAWINGS 1. THIS FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS FOR THEIR WORK. SUBMIT SIX (6) COPIES TO THE G.C. FOR ARCHITECTURAL APPROVAL OF HEAD LOCATIONS AND TYPES. 2. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, HYDRAULIC CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. 3. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE FORWARDED TO THE LANDLORD'S AGENT AND TO THE G.C.'S CONSTRUCTION MANAGER. C. EQUIPMENT AND INSTALLATION 1. SPRINKLER HEADS: A. FUSIBLE LINK TYPE AND STYLE AS INDICATED OR REQUIRED BY THE APPLICATION. UNLESS OTHERWISE INDICATED, PROVIDE HEADS WITH NOMINAL 1/2" DISCHARGE ORIFICE FOR "ORDINARY" TEMPERATURE RANGE. B. CONCEALED AUTOMATIC SPRINKLER HEAD (ALL BRANDS): MODEL #G-1, BRONZE HEAD WITH WHITE COVER PLATE BY RELIABLE AUTOMATIC SPRINKLER COMPANY OR EQUAL C. SEMI - RECESSED AUTOMATIC HEAD (BANANA REPUBLIC CLASSIC ONLY): MANAFACTURER VIKING, MODEL A1- 06662B. ESCUTCHEON (BANANA REPUBLIC CLASSIC ONLY): MANAFACTURER VIKING, MODEL F1-- 06911A. D. RECESSED AUTOMATIC SPRINKLER HEAD: MODEL #G WITH BRIGHT CHROME FINISH HEAD AND WHITE ESCUTCHEON BY RELIABLE AUTOMATIC SPRINKLER COMPANY INC. OR EQUAL. E. UPRIGHT AUTOMATIC SPRINKLER HEAD: MODEL #G WITH NATURAL BRONZE FINISH HEAD BY RELIABLE AUTOMATIC SPRINKLER COMPANY INC. OR EQUAL. F. SPRINKLER HEADS BY GLOBE, STAR, GRINNELL, VIKING OR CENTRAL SHALL BE CONSIDERED EQUAL G. SPRINKLER HEADS LOCATED IN CEIUNGS OR WALLS BELOW 8' -0" ABOVE THE FINISHED FLOOR AND ABOVE STORAGE DECKS ARE TO BE CONCEALED. 2. PIPING: A. COPPER TUBE AND FERROUS PIPE IN ACCORDANCE WITH NFPA -13 SECTION 3 -3 AND LANDLORD AND LOCAL CODE REQUIREMENTS. CPVC AND POLYBUTYLENE IS NOT PERMITTED. 3. A FIRE PROTECTION SYSTEM TAP IS NORMALLY FURNISHED BY THE LANDLORD. VERIFY IN FIELD PRIOR TO BID. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 SQ. FT. IN "STOCK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA AND LOCAL CODES IF MORE STRINGENT. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. 4. ALL SPRINKLER LINES SHALL BE INSTALLED AS HIGH AS POSSIBLE, AVOIDING INTERFERENCE WITH LIGHT FIXTURES, DUCTS, PIPES, STORAGE DECK, ETC. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER LINES, LIGHT FIXTURES, DUCTWORK, DIFFUSERS, GRILLES AND REGISTERS PRIOR TO INSTALLATION. 5.. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, LIGHT FIXTURE PLACEMENT, DUCTWORK, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. FURNISH AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR INSURANCE CARRIER. COORDINATE LOCATION WITH THE G.C.'S CONSTRUCTION MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH-IN. 7. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. 8. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND THE C.C.'S CONSTRUCTION MANAGER. 9. FURNISH AND INSTALL 10 LB. TYPE "ABC" FIRE EXTINGUISHERS, WITH CABINETS IF REQUIRED, AND AT LEAST A "2A1OBC" RATING. LOCATIONS TO BE ESTABLISHED IN THE FIELD BY THE G.C.'S CONSTRUCTION MANAGER AND THE LOCAL FIRE PROTECTION OFFICIAL. MAXIMUM TRAVEL DISTANCE BETWEEN EXTINGUISHERS SHALL BE 75 FEET OR LESS AS REQUIRED BY LOCAL CODES. END OF SECTION 15300 A. SCOPE OF WORK DIVISION 15 - MECHANICAL SECTION 15500 HEATING, VENTILATION, AND AIR CONDITIONING 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188 -2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 CONSULTANT INFO: NEM NOME k Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project # 2079563 PROFESSI ■ tO cl .. A _ A S T \ _ t 4 ._38 T ' 'y (§5'' .. sONA.1.. EXPIRES 2 6 01 Firm Registration No. 2002 ARCHITECT INFO: McCall Design Group 550 Keamy Street Suite 710 San Francisco CA 94108 t.415.288.81so L415.288.8181 www.mccclldesign.com ISSUE TYPE: LL /PERMIT /BID 12/21/07 ISSUE SCALE: NOT TO SCALE DRAWN BY: DKZNVKK JOB NO.: 207338 SHEET TITLE: MECHANICAL SPECIFICATIONS SHEET NUMBER: M5 -1 A. HVAC UNITS, EQUIPMENT, AND APPURTENANCES (UNLESS NOTED OTHERWISE). B. DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. C. CURBS, ROOFING, AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). D. CONDENSATE PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). E. TEMPERATURE /LIGHTING CONTROLS 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOBSITE AND EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES TO MEET STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. HVAC EQUIPMENT 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED BY THE OWNER AS SCHEDULED UNLESS NOTED OTHERWISE. REFER TO PLANS AND SCHEDULES FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3. EQUIPMENT SHALL BE INSTALLED AND START -UP PERFORMED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. C. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED NO DUCTWORK SHALL BE FABRICATED PRIOR TO JOB SITE VISIT AND APPROVAL BY THE G.C.. 1. SIGNIFICANT DEVIATIONS IN ROUTING OR SIZING OF THE DUCTWORK /PIPING SYSTEMS MUST BE CLOUDED AND NOTED ON THE SHOP DRAWINGS. THESE SIGNIFICANT DEVIATIONS MUST BE APPROVED BY THE OWNER'S ENGINEER PRIOR TO FABRICATION OR INSTALLATION. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND. 2. DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. WHERE OTHER CODES ARE ENFORCED, (IE. UMC, BOCA, ETC.) USE THE MOST STRINGENT CODE FOR DUCT CONSTRUCTION STANDARDS. ROUND AND FLAT OVAL DUCTWORK 3. ALL ROUND AND FLAT OVAL SUPPLY, RETURN AND EXHAUST DUCTWORK SHALL A. BE LINDAB, UNITED MCGILL OR SEMCO DUCT SYSTEMS CONSISTING OF FITTINGS THAT ARE FACTORY FITTED WITH A SEALING GASKET AND SPIRAL DUCT WHICH, WHEN INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS, WILL SEAL THE DUCT JOINTS WITHOUT THE USE OF DUCT SEALER. MATERIAL: ALL DUCT AND FITTINGS SHALL BE G -90 OR G -60 GALVANIZED B. STEEL IN ACCORDANCE WITH ASTM A -643 AND A -924. CONSTRUCTION: ALL DUCT AND FITTINGS SHALL BE CONSTRUCTED PER C. SMACNA'S DUCT CONSTRUCTION STANDARDS +10 IN W.G. D. FITTINGS: a. ALL FITTING ENDS SHALL COME FACTORY EQUIPPED WITH A SEALING GASKET. GASKET SHALL BE CLASSIFIED BY UNDERWRITER'S LABORATORIES TO CONFORM TO ASTM E84 -91A AND NFPA 90A FLAMESPREAD AND SMOKE DEVELOPED RATINGS OF 25/50. ALL FITTINGS SHALL BE CONTINUOUSLY STITCH WELDED OR SHALL BE STANDING b. SEAM GORELOCK CONSTRUCTION AND INTERNALLY SEALED. THE RADIUS OF ALL 90' AND 45' ELBOWS SHALL BE 1.5 TIMES THE ELBOW c. DIAMETER. THE RADIUS OF ALL 15', 30'AND 60' ELBOWS SHALL BE 1.0 TIMES THE ELBOW DIAMETER. ALL FITTINGS THAT ARE OF EITHER SPOT WELDED OR BUTTON PUNCHED WELDED d. OR BUTTON PUNCHED CONSTRUCTION SHALL BE INTERNALLY SEALED. WHEN CONTRACT DOCUMENTS REQUIRE DIVIDED FLOW FITTINGS ONLY FULL BODY FITTINGS WILL BE ACCEPTED. ALL BRANCH CONNECTIONS SHALL BE MADE AS A SEPARATE FITTING. FIELD INSTALLATION OF TAPS INTO SPIRAL DUCT SHALL NOT BE ALLOWED. ALL VOLUME DAMPERS SHALL BE FITTING SIZED TO SLIP INTO SPIRAL DUCT. e. DAMPER SHALL HAVE THE FOLLOWING FEATURES: LOCKING QUADRANT WITH BLADE POSITION INDICATOR 2" SHEET METAL INSULATION STAND -OFF INTEGRAL SHAFT /BLADE ASSEMBLY SHAFT MOUNTED, LOAD BEARING BUSHINGS GASKETED SHAFT PENETRATIONS TO MINIMIZE LEAKAGE. E: PERFORMANCE: SELF SEALING DUCT SYSTEM PERFORMANCE SHALL MEET SMACNA'S LEAKAGE CLASS 3 REQUIREMENTS AT -10 IN W.G. TO +10 IN W.G. F. SUBMITTALS: SUBMIT MANUFACTURERS DUCT SYSTEM CATALOG DATA FOR REVIEW AND APPROVAL. SUBMIT SHALL INCLUDE DUCT, FITTING AND SELF SEALING GASKET CATALOG INFORMATION. 4. RECTANGULAR DUCTWORK A. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS:2" W.G., POSITIVE RETURN DUCTS: 2" W.G., NEGATIVE B. EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS:CLASS B 3" W.G. RETURN DUCTS: CLASS C 2" W.G. IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. C. AS A MINIMUM, CROSS BREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/8" WIDE X 3/16" DEEP ON 12 CENTERS TO PREVENT VIBRATIONS, REGARDLESS OF DUCT GAUGE. D. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN ALL 90 DEGREE ELBOWS OVER 36" IN LENGTH. INSTALL FACTORY MANUFACTURED SINGLE THICKNESS TURNING VANES IN ALL OTHER ELBOWS. E. ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASS- FIBER- FABRIC REINFORCED TAPE. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. F. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. G. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. H. PROVIDE ACCESS TO ALL MOTORIZED ZONE DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION I5 EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY THE G.C.'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WHEN WITHIN 3'- 0" OF DEVICE. I. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. REFER TO DETAILS. 5. SUPPORT SYSTEMS A. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. B. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 1/2 "X1 -1/2" X1/8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 6. DUCTWORK CLEANING FOR PAINT APPLICATION A. ALL DUCTWORK REQUIRING PAINTING AND EXPOSED IN SALES AREAS AND FITTING ROOMS SHALL BE PHOSPHATIZED OR "PAINTGRIP" SPIRAL GALVANIZED UNINSULATED SHEET METAL EXCEPT FOR SPIRAL DUCTWORK BY LINDAB PRODUCTS WHICH IS TO BE PREPARED ACCORDING TO THE PAINT MANUFACTURES RECOMMENDATIONS FOR THE ADHERENCE OF PAINT. SURFACES SHALL BE CLEAN, DRY AND FREE FROM SPIRAL MANUFACTURER'S LUBRICANTS THAT WILL ADVERSELY AFFECT ADHESION OR APPEARANCE OF APPLIED PAINT COATING. REMOVE ALL DIRT AND GREASE FROM GALVANIZED SPIRAL DUCTWORK WITH A WATER BASED COMMERCIAL DETERGENT AND WIPE DRY WITH DRY CLEAN CLOTHS. SURFACE SHALL BE FREE OF ALL FOREIGN MATERIALS. D. FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ROOFTOP UNITS, ETC.) ND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE - COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. E. VIBRATION ISOLATION DEVICES 1. VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND STRUCTURE. 2. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 3. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITION WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. 4. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 5. CONSULT MANUFACTURER FOR APPLICATION DATA. F. FLEXIBLE AIR DUCT 1. FLEXIBLE AIR DUCT SHALL BE 1 INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS. FLEXIBLE AIR DUCT MAY ONLY BE USED IN CONCEALED VERTICAL APPLICATIONS WITHOUT PRIOR APPROVAL FROM G.C.'S CONSTRUCTION MANAGER UNLESS NOTED OTHERWISE. 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5' -O" IN LENGTH AT ANY ONE LOCATION. G. MANUAL DAMPERS 1. FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. H. FIRE DAMPERS & SMOKE FIRE DAMPERS 1. FIRE DAMPERS SHALL BE RUSKIN MODEL NO. FD36, FD6OFA OR FDR25. 2. PROVIDE FIRE DAMPERS WITH ACCESS DOORS INSTALLED WHERE REQUIRED BY ALL LOCAL CODES. 3. COMBINATION SMOKE FIRE DAMPERS SHALL BE RUSKIN MODEL NO. FSD36, FSD6OFA, OR FSDR25. I. DUCTWORK INSULATION & LINING 1. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. 2. DUCTWORK SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INCREASE DUCTWORK SIZES AS REQUIRED FOR INTERNALLY LINED DUCT TO MAINTAIN INSIDE CLEAR DIMENSIONS. 3. ALL RECTANGULAR SUPPLY DUCTWORK WITHIN 15 FEET AND RETURN DUCTWORK WITHIN 10 FEET OF THE HVAC UNIT SHALL BE INTERNALLY LINED. INTERNAL LINING SHALL BE 1 INCH THICK, 1 -1/2 LB DENSITY LINER. LINER SHALL HAVE A COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES SHALL BE COATED WITH ADHESIVE. 4. INSULATE ALL OF THE FOLLOWING DUCTWORK: CONCEALED SUPPLY DUCTWORK THAT IS NOT INTERNALLY LINED, UNTREATED OUTSIDE AIR DUCTWORK LOCATED WITHIN THE INTERIOR, ALL EXTERIOR SUPPLY AND RETURN AIR DUCTWORK INSULATION SHALL BE 1-1/2" REINFORCED FOIL FACED, VAPOR SEALED FIBERGLASS. INSTALLED THERMAL RESISTANCE SHALL BE AT LEAST 4.5 FOR INTERIOR DUCTWORK AND 6.0 FOR EXTERIOR DUCTWORK, OR AS REQUIRED BY LOCAL CODE, WHICHEVER IS MORE STRINGENT. PROVIDE EXTERIOR DUCTWORK INSULATION WITH WEATHERPROOF JACKETING. 5. ALL INSULATION AND LINING SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. J. CURBS AND STEEL FRAMING FOR SUPPORT 1. THIS CONTRACTOR WILL FURNISH AND INSTALL ALL NECESSARY CURBS AND BLOCKING REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED OR IMPLIED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14" HIGH OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED, UNLESS NOTED OTHERWISE. INSULATE UNDER THE COMPRESSOR SECTION. ALL CURBS MUST BE INSTALLED SO THAT TOP OF CURBS ARE "DEAD" LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. COORDINATE STEEL FRAMING REQUIREMENTS, ROOF PENETRATIONS, AND ROOF FLASHING WITH G.C. TO DETERMINE SCOPE OF WORK PRIOR TO BID. THIS CONTRACTOR MUST RECEIVE WRITTEN APPROVAL BEFORE ANY ADDITIONAL WORK TAKES PLACE. K. CONDENSATE PIPING 1. INTERIOR CONDENSATE PIPING SHALL BE TYPE "L" DRAWN COPPER TUBE WITH 95 -5 TIN - ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. DRAIN SHALL TERMINATE AT A CODE APPROVED LOCATION. ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER TRADES. SUBSTITUTIONS MUCT BE LISTED AND QUALIFIED IN BID. 2. EXTERIOR CONDENSATE PIPING SHALL BE TYPE "L" DRAWN COPPER. DRAIN SHALL TERMINATE AT A CODE APPROVED LOCATION. 3. INSULATE ALL INTERIOR CONDENSATE PIPING WITH 1 THICK (K =0.23 @ 75 F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. 4. INSTALL ALL NECESSARY PIPE HANGERS, AND SADDLES TO PROPERLY SUPPORT ALL CONDENSATE PIPING. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. L REFRIGERANT PIPING 1 THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN THE INDOOR FAN UNITS AND OUTDOOR FAN UNITS. 2. PIPING A. REFRIGERANT PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBING (ASTMB88). TUBING SHALL BE CLEAN, CAPPED AND NITROGEN CHARGED. B. ALL FITTING AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI B16.22). ALL COPPER TO COPPER JOINTS SHALL BE BRAZED WITH A COPPER - PHOSPHORUS ALLOY AND ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS -5 ALLOY. C. 3. INSTALLATION 4. INSPECTION ALL ELBOWS SHALL BE LONG RADIUS TYPE. A. SUCTION LINES SHALL HAVE ADEQUATE LIFT TRAPS AND /OR DOUBLE SUCTION RISERS TO MEET THE REQUIREMENTS OF FIELD CONDITIONS AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. B. BRAZE ALL JOINTS WITH SILFOS -5 STARTING AT THE INDOOR UNIT AND WORKING TOWARD THE OUTDOOR UNIT. THE SEALS ON THE OUTDOOR UNIT SHALL BE BROKEN LAST. A NITROGEN BLEED SHALL BE USED DURING ALL BRAZING AND ANY TIME THE SYSTEM IS OPEN. ALL OPEN UNES SHALL BE CAPPED AND SEALED BEFORE LEAVING THE SITE DURING CONSTRUCTION. PRESSURE TEST FOR LEAKS WITH AN INERT GAS UP TO 245 PSIG. REDO LEAKING JOINTS AND RETEST UNIT SYSTEM IS TIGHT. EVACUATE ENTIRE SYSTEM TO 200 MICRONS OF MERCURY. CHARGE SYSTEM WITH 25 PSI OF R -22 AND AN INERT GAS TO 245 PSI AND RETEST SYSTEM WITH HALIDE LEAK DETECTOR. ALL LEAKING JOINTS MUST BE COMPLETELY RESEALED UNTIL NO LEAKS EXIST. TURN ON CRANK CASE HEATERS 24 HRS PRIOR TO STARTING COMPRESSOR TO BE SURE ALL REFRIGERANT LIQUID IS OUT OF THE COMPRESSOR. C. UPON COMPLETION OF TESTING, BUT BEFORE THE REFRIGERANT PIPING INSULATION I5 APPLIED, THE PIPING MUST BE INSPECTED BY AWINGS. REPRESENTATIVE OF THE LOCAL GOVERNING AUTHORITY AS NECESSARY. D. INSULATE THE REFRIGERANT SUCTION LINES AND CONDENSATE UNES ONLY WITH RUBATEX OR ARMSTRONG 1 INCH THICK PIPE INSULATION WITH FLAME SPREAD RATING OF NOT MORE THAN 50 IN ACCORDANCE WITH INDUSTRY STANDARDS. DO NOT INSULATE THE HOT GAS (LIQUID) LINES OR ANY HOT GAS BYPASS LINES IF APPLICABLE. A. CONTRACTOR MUST PREPARE AND SUBMIT A COMPLETE PIPING SCHEMATIC TO THE LOCAL CARRIER FIELD REPRESENTATIVE FOR APPROVAL PRIOR TO BEGINNING INSTALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST CALL THE LOCAL CARRIER INSPECTOR FOR FIELD INSPECTION OF WORK PERFORMED AT G.C.'S EXPENSE. ALL ITEMS FOUND TO BE INADEQUATE FOR PROPER PERFORMANCE BY CARRIER FIELD REPRESENTATIVE MUST BE CORRECTED AT NO ADDITIONAL CHARGES TO G.C. OR THE OWNER. M. HYDRONIC PIPING 1. FURNISH AND INSTALL A COMPLETE HYDRONIC PIPING SYSTEM AS REQUIRED. 2. PIPING A. HYDRONIC PIPING FOR CHILLED WATER, CONDENSER WATER AND /OR HEATING WATER SHALL BE ASTM A53, SCHEDULE 40, STANDARD WIEGHT, BLACK STEEL PIPE OR TYPE "M" COPPER TUBE. BLACK STEEL PIPE SHALL HAVE WELDED FITTINGS FOR PIPE 2 -1/2" AND LARGER AND 300# MALLEABLE IRON FITTINGS FOR PIPE 2" AND SMALLER. COPPER TUBE SHALL UTILIZE WROUGHT COPPER FITTINGS WITH 95 -5 SOLDER OR SILFOS FOR PRESSURES GREATER THAN 50 PSI. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMANCE WITH ASTM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER IS MOST STRINGENT. UNIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE REQUIRED. B. ALL PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. C. ALL HYDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PIPING SYSTEM SHALL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE STRAINER SCREENS. FILL TENANT'S SYSTEM WITH DOMESTIC WATER VENT ALL PIPING AND EQUIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FROM THE LANDLORD'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO SO FROM THE LANDLORD'S FIELD REPRESENTATIVE. D. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION FROM THE LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHING, AND PROPER FILLING OF THE TENANT'S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANT'S SYSTEM IS READY TO BE CONNECTED TO THE LANDLORD'S SYSTEM. 3. VALVES A. GATE VALVES, 2 -INCH AND SMALLER: CLASS 150, BODY AND UNION BONET OF ASTM B62 CAST BRONZE WITH THREADED OR SOLDER ENDS, INTEGRAL SEAT, RENEWABLE SOLID BRONZE WEDGE DISC, RISING STEM, SCREWED BONNET AND RE- PACKABLE UNDER PRESSURE. BALL VALVES ARE ACCEPTED AS AN EQUAL SUBSTITUTION. 3. INSULATE ALL INTERIOR CONDENSATE PIPING WITH 1" THICK (K =0.23 ® 75 F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. C. SWING CHECK VALVES, 2 -INCH AND SMALLER: CLASS 150, CAST BRONZE BODY AND CAP CONFORMING TO ASTM B62 WITH HORIZONTAL SWING, Y- PATTERN, RENEWABLE BRONZE DISC, AND HAVING THREADED OR SOLDERED ENDS. D. SWING CHECK VALVES, 2-1/2 INCH AND LARGER: CLASS 125, CAST IRON BODY AND BOLTED CAP, HORIZONTAL SWING, RENEWABLE BRONZE DISC, FLANGED ENDS AND CAPABLE OF BEING REFITTED WHILE THE VALVE REMAINS IN THE LINE. E. COMBINATION BALANCING AND SHUT -OFF VALVES: BELL & GOSSETT CIRCUIT SLI ILR WITH LOCKING SET POINT. A CIRCUIT SETTER BALANCE WHEEL MUST BE INCLUDED WITH 0 &M MANUAL. TACO OR HOMESTEAD ARE CONSIDERED AS EQUAL. 4. PIPING SPECIALTIES A. PRESSURE/TEMPERATURE TEST PLUGS (PETE'S PLUG) - 1/4 INCH NPT FITTINGS TO RECEIVE EITHER A TEMPERATURE OR PRESSURE PROBE, 1/8 INCH 0.D. FITTING AND CAPS SHALL BE BRASS WITH VALVE CORE OF NORDEL, RATED AT 400 PSIG AT 0 DEG F TO 200 DEG F B. STRAINERS - 'Y" PATTERN STRAINERS, 125 PSIG, CAST IRON BODY WITH PERFORATED STAINLESS STEEL SCREEN, THREADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2 -1/2 INCHES AND LARGER. SCREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INCH FOR CHILLED OR CONDENSER WATER. PROVIDED WITH BLOWDOWN VALVE WITH HOSE END FITTING. C. 5. INSULATION THERMOFLO INDICATOR - BELL & GOSSETT MODEL "TFI" A. ALL HYDRONIC PIPING FOR CHILLED WATER AND HEATING WATER (NOT INCLUDING CONDENSER WATER UNLESS SPECIFICALLY NOTED OTHERWISE), VALVES, FITTINGS, AND ACCESSORIES SHALL BE INSULATED. FOR PIPE SIZES UP TO 2 INCHES, INSULATE WITH 1 INCH THICK (K =0.23 ® 75 DEG F) FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. FOR PIPE SIZES 2 -1/2 INCHES AND LARGER, INSULATE WITH 1 -1/2 INCH THICK (K =0.23 @ 75 DEG F) FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. B. INSULATION AT ALL HANGERS FOR PIPING 2 -1/2 INCHES AND LARGER SHALL BE HARD AND NON - COMPRESSIBLE. C. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 50 TO CONFORM WITH NFPA REQUIREMENTS. D. PROVIDE ZESTON OR EQUAL INSULATION FITTINGS FOR ALL TEES, ELLS OR SPECIALTY FITTINGS. 6. GENERAL INSTALLATION A. INSTALL WATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. B. BRANCHES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE _ PITCHED UPWARD TOWARDS UNITS. PITCH NOT 1 . : LESS THAN 1 PER 10 FEET. � C. REFER TO MECHANICAL DRAWINGS FOR APPLICABLE DETAILS. PART 1 GENERAL 1.1 SUMMARY SECTION 15950 TESTING, ADJUSTING, AND BALANCING A. SECTION INCLUDES TESTING, ADJUSTING, AND BALANCING OF AIR, WATER AND REFRIGERATION SYSTEMS AND MEASUREMENT OF FINAL OPERATING CONDITION OF HVAC SYSTEMS. 1.2 REFERENCES A. AABC (ASSOCIATED AIR BALANCE COUNCIL) - NATIONAL STANDARDS FOR TOTAL SYSTEM BALANCE. B. NEBB (NATIONAL ENVIRONMENTAL BALANCING BUREAU) - PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS. 1.3 SUBMITTALS A. TEST REPORTS: THE TAB REPORT SHALL BE IN THE FORMAT OF THE AABC NATIONAL STANDARD REPORT OR THE NEBB CERTIFIED REPORT FORMS AS PUBLISHED IN THEIR MOST CURRENT EDmONS. 1.4 QUALITY ASSURANCE B. FURNISH FOUR COPIES OF REPORTS, COMPLETE WITH TABLE OF CONTENTS PAGE AND INDEXING TABS AND WITH COVER IDENTIFICATION AT FRONT. INCLUDE SET OF REDUCED INDEX DRAWINGS WITH AIR OUTLETS AND EQUIPMENT IDENTIFIED TO CORRESPOND WITH DATA SHEETS, AND INDICATING THERMOSTAT LOCATIONS. C. INCLUDE A COPY OF AABC NATIONAL PROJECT PERFORMANCE GUARANTY OR COPY OF NEBB CERTIFICATE OF CONFORMANCE CERTIFICATION. 9 A. PERFORM WORK IN ACCORDANCE WITH AABC NATIONAL STANDARDS FOR FIELD MEASUREMENT AND INSTRUMENTATION, TOTAL SYSTEM BALANCE OR NEBB PROCEDURAL STANDARDS FOR TESTING, BALANCING AND ADJUSTING OF ENVIRONMENTAL SYSTEMS 1.5 QUALIFICATIONS A. THE TESTING, ADJUSTING AND BALANCING (TAB) OF ALL WORK SHALL BE PERFORMED BY AN INDEPENDENT CONTRACTOR THAT I5 CURRENTLY REMITS) LICENSED BY AABC OR NEBB. THE COMPANY SHALL SPECIALIZE IN TAB OF CM OP 11 A;y4Vi1 A SYSTEMS SPECIFIED IN THIS SECTION AND SHALL HAVE A MINIMUM THREE YEARS DOCUMENTED EXPERIENCE CERTIFIED BY AABC OR NEBB. IDEC 2 7 2001 NEW STORE BANANA REPUBLIC GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 STORE NO.: 8997 STORE NAME: SOUTHCENTER MALL STORE LOCATION: 633 Southcenter Parkway Tukwila, WA 98188-2888 GAP PROJ. I.D.: 0000042134 PROTOTYPE DATE: 06/15/07 OPENING 2008 CONSULTANT INFO: I s � Consulting Engineers Energy Engineering Associates, Inc. 6615 Vaught Ranch Rd Austin, Texas 78730 (512) 744 -4400 EEA Project #2079563 ' I PROF SSIO " I I 4 4 B. PERFORM WORK UNDER SUPERVISION OF AABC CERTIFIED TEST AND BALANCE ENGINEER OR NEBB CERTIFIED TESTING, BALANCING AND ADJUSTING SUPERVISOR EXPERIENCED IN PERFORMANCE OF THIS WORK AND UCENSED AT PLACE WHERE PROJECT IS LOCATED. 1.6 TIMING A. THE COMPLETE TAB REPORTS SHALL BE PROVIDED TO THE OWNER NO LATER THAN ONE (1) WEEK PRIOR TO CONSTRUCTION END DATE. PART 2 PRODUCTS NOT USED. PART 3 EXECUTION 3.1 HVAC CONTRACTOR RESPONSIBILITIES A. THE HVAC CONTRACTOR SHALL VERIFY THAT THE HVAC SYSTEMS ARE COMPLETE AND OPERABLE BEFORE TAB WORK IS STARTED. THE HVAC CONTRACTOR SHALL BE PRESENT DURING THE TEST ADJUSTING AND BALANCING OF THE HVAC SYSTEM TO PROVIDE ASSISTANCE TO THE TAB CONTRACTOR. REQUIREMENTS INCLUDE THE FOLLOWING: 1. SYSTEMS ARE STARTED AND OPERATING IN SAFE AND NORMAL CONDITION. 2. TEMPERATURE CONTROL SYSTEMS ARE INSTALLED COMPLETE AND OPERABLE. 3. ALL BALANCING DEVICES AND HVAC EQUIPMENT ARE ACCESSIBLE 4. PROPER THERMAL OVERLOAD PROTECTION IS IN PLACE FOR ELECTRICAL EQUIPMENT. 5. NEW AIR FILTERS ARE INSTALLED JUST PRIOR TO AIR BALANCE AND IMMEDIATELY AFTER PROJECT IS COMPLETE. 6. DUCT SYSTEMS ARE CLEAN OF DEBRIS. 7. FANS ARE ROTATING CORRECTLY. 8. FIRE AND VOLUME DAMPERS ARE IN PLACE AND OPEN. 9. AIR COIL FINS ARE CLEANED AND COMBED. 10. ACCESS DOORS ARE CLOSED AND DUCT END CAPS ARE IN PLACE. 11. AIR OUTLETS ARE INSTALLED AND CONNECTED. 12. DUCT SYSTEM LEAKAGE 15 MINIMIZED. 13. HYDRONIC SYSTEMS ARE FLUSHED, FILLED, AND VENTED. 14. PUMPS ARE ROTATING CORRECTLY. 15. PROPER STRAINER BASKETS ARE CLEAN AND IN PLACE OR IN NORMAL POSITION. 16. SERVICE AND BALANCING VALVES ARE OPEN. B. IF THE TAB CONTRACTOR DETERMINES THAT A FAN SHEAVE OR BELT REPLACEMENT IS NEEDED TO MEET THE BALANCING REQUIREMENTS, THEN THE HVAC CONTRACTOR SHALL REPLACE THE FAN SHEAVE /BELT AS REQUIRED. THE HVAC CONTRACTOR SHALL NOTIFY THE OWNER IN WRITING OF THE REPLACEMENT WORK. 3.2 INSTALLATION TOLERANCES A. ALL AIR AND WATER SYSTEMS MUST BE BALANCED WITHIN PLUS OR MINUS 10% OF DESIGN. 3.3 ADJUSTING A. VERIFY RECORDED DATA REPRESENTS ACTUAL MEASURED OR OBSERVED CONDIT10NS. B. PERMANENTLY MARK SETTINGS OF VALVES, DAMPERS, AND OTHER ADJUSTMENT DEVICES ALLOWING SETTINGS TO BE RESTORED. SET AND LOCK MEMORY STOPS. C. AFTER ADJUSTMENT, TAKE MEASUREMENTS TO VERIFY BALANCE HAS NOT BEEN DISRUPTED. IF DISRUPTED, VERIFY CORRECTING ADJUSTMENTS HAVE BEEN MADE. D. LEAVE SYSTEMS IN PROPER WORKING ORDER, REPLACING BELT GUARDS, CLOSING ACCESS DOORS, CLOSING DOORS TO ELECTRICAL SWITCH BOXES, AND RESTORING THERMOSTATS TO SPECIFIED SETTINGS. E. AT FINAL INSPECTION, RECHECK RANDOM SELECTIONS OF DATA RECORDED IN REPORT. RECHECK POINTS OR AREAS AS SELECTED AND WITNESSED BY OWNER. 3.4 AIR SYSTEM PROCEDURE A. ADJUST AIR HANDLING AND DISTRIBUTION SYSTEMS TO OBTAIN REQUIRED OR DESIGN SUPPLY, RETURN, AND EXHAUST AIR QUANTITIES [AT SITE ALTITUDE]. B. MAKE AIR QUANTITY MEASUREMENTS IN MAIN DUCTS BY PITOT TUBE TRAVERSE OF ENTIRE CROSS SECTIONAL AREA OF DUCT. C. MEASURE AIR QUANTITIES AT AIR INLETS AND OUTLETS. D. ADJUST DISTRIBUTION SYSTEM TO OBTAIN UNIFORM SPACE TEMPERATURES FREE FROM OBJECTIONABLE DRAFTS. E. USE VOLUME CONTROL DEVICES TO REGULATE AIR QUANTITIES ONLY TO EXTENT ADJUSTMENTS DO NOT CREATE OBJECTIONABLE AIR MOTION OR SOUND LEVELS. EFFECT VOLUME CONTROL BY VOLUME DAMPERS LOCATED IN DUCTS. F. VARY TOTAL SYSTEM AIR QUANTITIES BY ADJUSTMENT OF FAN SPEEDS. PROVIDE SHEAVE DRIVE CHANGES TO VARY FAN SPEED. VARY BRANCH AIR QUANTITIES BY DAMPER REGULATION. G. PROVIDE SYSTEM SCHEMATIC WITH REQUIRED AND ACTUAL AIR QUANTITIES RECORDED AT EACH OUTLET OR INLET. H. MEASURE STATIC AIR PRESSURE CONDITIONS ON AIR SUPPLY UNITS, INCLUDING FILTER AND COIL PRESSURE DROPS, AND TOTAL PRESSURE ACROSS FAN. MAKE ALLOWANCES FOR 50 PERCENT LOADING OF FILTERS. I. ADJUST OUTSIDE AIR AUTOMATIC DAMPERS, OUTSIDE AIR, RETURN AIR, AND EXHAUST DAMPERS DESIGN CONDITIONS. J. MEASURE TEMPERATURE CONDITIONS ACROSS OUTSIDE AIR, RETURN AIR, AND EXHAUST DAMPERS TO CHECK LEAKAGE. K. AT MODULATING DAMPER LOCATIONS, TAKE MEASUREMENTS AND BALANCE AT EXTREME CONDTONS. [BALANCE VARIABLE VOLUME SYSTEMS AT MAXIMUM AIRFLOW RATE, FULL COOUNG, AND AT MINIMUM AIRFLOW RATE, FULL HEATING. L. FOR VARIABLE AIR VOLUME SYSTEM POWERED UNITS SET VOLUME CONTROLLER TO AIRFLOW SETTING INDICATED. CONFIRM CONNECTIONS PROPERLY MADE AND CONFIRM PROPER OPERATION FOR AUTOMATIC VARIABLE- AIR - VOLUME TEMPERATURE CONTROL. M. ON FAN POWERED VAV BOXES, ADJUST AIRFLOW SWITCHES FOR PROPER OPERATION. 3.5 WATER SYSTEM PROCEDURE A. ADJUST WATER SYSTEMS, AFTER AIR BALANCING, TO OBTAIN DESIGN QUANTITIES. B. USE CALIBRATED VENTURI TUBES, ORIFICES, OR OTHER METERED FITTINGS AND PRESSURE GAUGES TO DETERMINE FLOW RATES FOR SYSTEM BALANCE. WHERE FLOW- METERING DEVICES ARE NOT INSTALLED, BASE FLOW BALANCE ON TEMPERATURE DIFFERENCE ACROSS VARIOUS HEAT TRANSFER ELEMENTS IN SYSTEM. C. ADJUST SYSTEMS TO OBTAIN SPECIFIED PRESSURE DROPS AND FLOWS THROUGH HEAT TRANSFER ELEMENTS PRIOR TO THERMAL TESTING. PERFORM BALANCING BY MEASUREMENT OF TEMPERATURE DIFFERENTIAL IN CONJUNCTION WITH AIR BALANCING. D. EFFECT SYSTEM BALANCE WITH AUTOMATIC CONTROL VALVES FULLY OPEN OR IN NORMAL P05mON TO HEAT TRANSFER ELEMENTS. E. EFFECT ADJUSTMENT OF WATER DISTRIBUTION SYSTEMS BY MEANS OF BALANCING COCKS, VALVES, AND FITTINGS. DO NOT USE SERVICE OR SHUT- OFF VALVES FOR BALANCING UNLESS INDEXED FOR BALANCE POINT. F. WHERE AVAILABLE PUMP CAPACITY 15 LESS THAN TOTAL FLOW REQUIREMENTS OR INDIVIDUAL SYSTEM PARTS, SIMULATE FULL FLOW IN ONE PART BY TEMPORARY RESTRICTION OF FLOW TO OTHER PARTS. 3.6 REPORTS A. REFER TO PLANS FOR EQUIPMENT DESIGN DATA SCHEDULES. B. REPORT FORMS 1. TITLE PAGE: A. NAME OF TESTING, ADJUSTING, AND BALANCING AGENCY B. ADDRESS OF TESTING, ADJUSTING, AND BALANCING AGENCY C. TELEPHONE AND FACSIMILE NUMBERS OF TESTING, ADJUSTING, AND BALANCING AGENCY D. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF CONTRACTOR E. PROJECT NAME F. PROJECT LOCATION G. PROJECT ARCHITECT H. PROJECT ENGINEER I. PROJECT CONTRACTOR J. PROJECT ALTITUDE K. DATE TAB WAS PERFORMED: 2. SUMMARY COMMENTS: A. COPY OF CERTIFICATE OF CONFORMANCE WITH NATIONAL STANDARDS (AABC OR NEBB) FOR THIS PROJECT. B. ACTUAL SPACE TEMPERATURES WITH CORRESPONDING THERMOSTAT SET POINTS FOR EACH UNIT. C. DESIGN VERSUS FINAL PERFORMANCE D. NOTABLE CHARACTERISTICS OF SYSTEM E. DESCRIPTION OF SYSTEMS OPERATION SEQUENCE F. SUMMARY OF OUTDOOR AND EXHAUST FLOWS TO INDICATE BUILDING PRESSURIZATION G. NOMENCLATURE USED THROUGHOUT REPORT H. TEST CONDITIONS 3. INSTRUMENT UST: A. INSTRUMENT B. MANUFACTURER C. MODEL NUMBER D. SERIAL NUMBER E. RANGE F. CALIBRATION DATE 4. AIR DISTRIBUTION TEST SHEET: A. AIR TERMINAL NUMBER B. ROOM NUMBER /LOCATION C. TERMINAL TYPE D. TERMINAL SIZE E. AREA FACTOR F. DESIGN VELOCITY G. DESIGN AIR FLOW H. TEST (FINAL) VELOCITY I. TEST (FINAL) AIR FLOW J. PERCENT OF DESIGN AIR FLOW 5. DUCT TRAVERSE: A. SYSTEM ZONE /BRANCH B. DUCT SIZE C. AREA D. DESIGN VELOCITY E. DESIGN AIR FLOW F. TEST VELOCITY G. TEST AIR FLOW H. DUCT STATIC PRESSURE I. AIR TEMPERATURE J. AIR CORRECTION FACTOR 6. ELECTRIC MOTORS FOR ALL HVAC EQUIPMENT: A. MANUFACTURER B. C. D. E. F. G. H. MODEL /FRAME HP /BHP AND KW PHASE, VOLTAGE, AMPERAGE; NAMEPLATE, ACTUAL, NO LOAD RPM SERVICE FACTOR STARTER SIZE, RATING, HEATER ELEMENTS SHEAVE MAKE /SIZE /BORE 7. V -BELT DRIVE: A. IDENTIFICATION /LOCATION B. REQUIRED DRIVEN RPM C. DRIVEN SHEAVE, DIAMETER AND RPM D. BELT, SIZE AND QUANTITY E. MOTOR SHEAVE DIAMETER AND RPM F. CENTER TO CENTER DISTANCE, MAXIMUM, MINIMUM, AND ACTUAL 8. COOLING COIL DATA: A. IDENTIFICATION /NUMBER B. LOCATION C. SERVICE D. MANUFACTURER E. AIR FLOW, DESIGN AND ACTUAL F. ENTERING AIR DB TEMPERATURE, DESIGN AND ACTUAL G. ENTERING AIR WB TEMPERATURE, DESIGN AND ACTUAL H. LEAVING AIR DB TEMPERATURE, DESIGN AND ACTUAL I. LEAVING AIR WB TEMPERATURE, DESIGN AND ACTUAL J. WATER FLOW, DESIGN AND ACTUAL K. WATER PRESSURE DROP, DESIGN AND ACTUAL L. ENTERING WATER TEMPERATURE, DESIGN AND ACTUAL M. LEAVING WATER TEMPERATURE, DESIGN AND ACTUAL N. SATURATED SUCTION TEMPERATURE, DESIGN AND ACTUAL 0. AIR PRESSURE DROP, DESIGN AND ACTUAL 9. HEATING COIL DATA: A. IDENTIFICATION /NUMBER B. LOCATION C. SERVICE D. MANUFACTURER E. AIR FLOW, DESIGN AND ACTUAL F. WATER FLOW, DESIGN AND ACTUAL G. WATER PRESSURE DROP, DESIGN AND ACTUAL H. ENTERING WATER TEMPERATURE, DESIGN AND ACTUAL I. LEAVING WATER TEMPERATURE, DESIGN AND ACTUAL J. ENTERING AIR TEMPERATURE, DESIGN AND ACTUAL K. LEAVING AIR TEMPERATURE, DESIGN AND ACTUAL L. AIR PRESSURE DROP, DESIGN AND ACTUAL B. C. D. E. F. G. H. J. K. C. D. E. F. G. H. J. K. L. M. N. 10. ELECTRIC DUCT HEATER: A. MANUFACTURER IDENTIFICATION /NUMBER LOCATION MODEL NUMBER DESIGN KW NUMBER OF STAGES PHASE, VOLTAGE, AMPERAGE TEST VOLTAGE (EACH PHASE) TEST AMPERAGE (EACH PHASE) AIR FLOW, SPECIFIED AND ACTUAL TEMPERATURE RISE, SPECIFIED AND ACTUAL 11. AIR MOVING EQUIPMENT A. LOCATION B. MANUFACTURER MODEL NUMBER SERIAL NUMBER ARRANGEMENT /CLASS /DISCHARGE AIR FLOW, SPECIFIED AND ACTUAL RETURN AIR FLOW, SPECIFIED AND ACTUAL OUTSIDE AIR FLOW, SPECIFIED AND ACTUAL TOTAL STATIC PRESSURE (TOTAL EXTERNAL), SPECIFIED AND ACTUAL INLET PRESSURE DISCHARGE PRESSURE SHEAVE MAKE /SIZE /BORE NUMBER OF BELTS /MAKE /SIZE FAN RPM 12. RETURN AIR /OUTSIDE AIR DATA: A. IDENTIFICATION /LOCATION B. DESIGN AIR FLOW C. ACTUAL AIR FLOW D. DESIGN RETURN AIR FLOW E. ACTUAL RETURN AIR FLOW F. DESIGN OUTSIDE AIR FLOW G. ACTUAL OUTSIDE AIR FLOW H. RETURN AIR TEMPERATURE I. OUTSIDE AIR TEMPERATURE J. REQUIRED MIXED AIR TEMPERATURE K. ACTUAL MIXED AIR TEMPERATURE 13. EXHAUST FAN DATA: A. LOCATION B. MANUFACTURER C. MODEL NUMBER D. SERIAL NUMBER E. AIR FLOW, SPECIFIED AND ACTUAL F. TOTAL STATIC PRESSURE (TOTAL EXTERNAL), SPECIFIED AND ACTUAL G. INLET PRESSURE H. DISCHARGE PRESSURE I. SHEAVE MAKE /SIZE /BORE J. NUMBER OF BELTS /MAKE /SIZE K. FAN RPM 14. VAV BOX DATA: A. MANUFACTURER B. TYPE, FAN POWERED, STANDARD C. IDENTIFICATION /NUMBER D. LOCATION E. MODEL NUMBER F. SIZE G. MINIMUM STATIC PRESSURE H. MINIMUM DESIGN AIR FLOW I. MAXIMUM DESIGN AIR FLOW J. MAXIMUM ACTUAL AIR FLOW K. INLET STATIC PRESSURE 15. AIR COOLED CONDENSER: A. IDENTIFICATION /NUMBER B. LOCATION C. MANUFACTURER D. MODEL NUMBER E. SERIAL NUMBER F. ENTERING DB AIR TEMPERATURE, DESIGN AND ACTUAL G. LEAVING DB AIR TEMPERATURE, DESIGN AND ACTUAL H. NUMBER OF COMPRESSORS 16. PUMP DATA: A. IDENTIFICATION /NUMBER B. MANUFACTURER C. SIZE /MODEL D. IMPELLER E. SERVICE F. DESIGN FLOW RATE, PRESSURE DROP, BHP AND KW G. ACTUAL FLOW RATE, PRESSURE DROP, BHP AND KW H. DISCHARGE PRESSURE I. SUCTION PRESSURE J. TOTAL OPERATING HEAD PRESSURE K. SHUT OFF, DISCHARGE AND SUCTION PRESSURES L. SHUT OFF, TOTAL HEAD PRESSURE 17. CHILLERS: A B. C. D. E. F. G. H. J. K. L. IDENTIFICATION /NUMBER MANUFACTURER CAPACITY MODEL NUMBER SERIAL NUMBER EVAPORATOR ENTERING WATER TEMPERATURE, DESIGN AND ACTUAL EVAPORATOR LEAVING WATER TEMPERATURE, DESIGN AND ACTUAL EVAPORATOR PRESSURE DROP, DESIGN AND ACTUAL EVAPORATOR WATER FLOW RATE, DESIGN AND ACTUAL CONDENSER ENTERING WATER TEMPERATURE, DESIGN AND ACTUAL CONDENSER PRESSURE DROP, DESIGN AND ACTUAL CONDENSER WATER FLOW RATE, DESIGN AND ACTUAL 18. COOLING TOWER: A. TOWER IDENTIFICATION /NUMBER B. MANUFACTURER C. MODEL NUMBER D. SERIAL NUMBER E. RATED CAPACITY F. ENTERING AIR WB TEMPERATURE, SPECIFIED AND ACTUAL G. LEAVING AIR WB TEMPERATURE, SPECIFIED AND ACTUAL H. AMBIENT AIR DB TEMPERATURE I. CONDENSER WATER ENTERING TEMPERATURE J. CONDENSER WATER LEAVING TEMPERATURE K. CONDENSER WATER FLOW RATE L. FAN RPM 19. HEAT EXCHANGER: A. IDENTIFICATION /NUMBER B. LOCATION C. SERVICE D. MANUFACTURER E. MODEL NUMBER F. SERIAL NUMBER G. STEAM PRESSURE, DESIGN AND ACTUAL H. PRIMARY WATER ENTERING TEMPERATURE, DESIGN AND ACTUAL I. PRIMARY WATER LEAVING TEMPERATURE, DESIGN AND ACTUAL J. PRIMARY WATER FLOW, DESIGN AND ACTUAL K. PRIMARY WATER PRESSURE DROP, DESIGN AND ACTUAL L. SECONDARY WATER LEAVING TEMPERATURE, DESIGN AND ACTUAL M. SECONDARY WATER LEAVING TEMPERATURE, DESIGN AND ACTUAL N. SECONDARY WATER FLOW, DESIGN AND ACTUAL 0. SECONDARY WATER PRESSURE DROP, DESIGN AND ACTUAL 20. TAB PROCESS & PROCEDURE TAB CONTRACTOR SHALL PROVIDE INITIAL REPORT TO GENERAL A. CONTRACTOR FOR REVIEW. IF ANY ITEMS ON TAB REPORT ARE NOT WITHIN PLUS OR MINUS 10 % OF DESIGN. TAB AND GENERAL CONTRACTOR SHALL MAKE THE APPROPRIATE CHANGES TO MEET DESIGN SPECIFICATION. IF DESIGN SPECIFICATION CAN NOT BE MET SUBMIT A DEFICIENCY REPORT TO GAP INC. FOR REVIEW. GENERAL CONTRACTOR TO SUBMIT FINAL TAB REPORT TO GAP INC. WHEN ALL ITEMS ARE WITHIN SPECIFICATION. END OF SECTION L NOTE: 1 THIS IS A STANDARD SPECIFICATION, NOT ALL SECTIONS ARE USED. RECEIVED CITY OF TL ( KVtr6i.A IDEC 2 7 MIT PERMIT GE1N + �:�