Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-293 - B & K TAYLOR
B & K TAYLOR 960 INDUSTRY DR M07 -293 Parcel No.: 2523049015 Address: Suite No: 960 INDUSTRY DR TUKW Citf Tukwila Tenant: Name: B & K TAYLOR Address: 960 INDUSTRY DR , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tulwila.wa.us Owner: Name: WALTON CWWA TUKWILA 1 LLC Address: 900 N MICHIGAN AVE #1900 , CHICAGO IL Contact Person: Name: CHUCK GILLETTE Address: 720 132 ST SW SUITE 201 , EVERETT WA Contractor: Name: THOMAS INDUSTRIES INC Address: 20942 NE 78TH STREET , REDMOND, WA Contractor License No: THOMAII072P9 MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: REISSUE OF EXPIRED PERMIT M07 -029, INSTALL SPRAY BOOTH AND HEATED MAKE -UP AIR Value of Mechanical: $48,000.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 3uspended/Wall/Floor Mounted Heater 0 F ppliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Pik Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 1 Yood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 oc: IMC - 10/06 EOUIPMENT TYPE AND OUANTITY * *continued on next page ** Phone: Phone: 206 - 412 -9733 Phone: 425 868 -7742 Expiration Date: 10/15/2009 M07 -293 01/09/2008 07/07/2008 Fees Collected: $707.53 International Mechanical Code Edition: 2006 Boiler Compressor: 0 - 3 HP/ 100,000 BTU 0 3 - 15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 1 M07 -293 Printed: 01 -09 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied ioc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -293 Issue Date: 01/09/2008 Permit Expires On: 07/07/2008 *, Date: Minh rt fin this permit and know the same to be true and correct. All provisions of law and ordinances th, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p rformance o ork. I am authorized to sign and obtain this mechanical permit. Signature: 1 Date: Print Name: C / : This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -293 Printed: 01 -09 -2008 Parcel No.: 2523049015 Address: Suite No: Tenant: loc: Cond -10/06 U• City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 960 INDUSTRY DR TUKW B & K TAYLOR PERMIT CONDITIONS 1: ** *BUILDING DEPARTMENT COND1TiONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -feed appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. B: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: M07 -293 ISSUED 12/27/2007 01/09/2008 M07 -293 Printed: 01 -09 -2008 Print Name: / City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature:/ /�'/ /' Date: / '7 "736 loc: Cond -10/06 M07 -293 ordinances governing or local laws regulating Printed: 01 -09 -2008 CITY OF TUKWI Community DevelopmenThepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwatukwila.wa.us SITE LOCATION Site Address: N19p ST Tenant Name: Property Owners Name: y in v &Azod E2i/ vic Mailing Address: SDO J 4UST/t,/ M. 7 /GSt h1- 9 / CONTACT PERSON '- " Who .do we contact when your permit is ready to be issued Name: C//1/l k Mailing Address: Zp / . 2 - 57' S. /,.. / S d /7 ? (71 E -Mail Address: c'hiv4ee. Firy /5/,t /4i. , 014A Company Name: 7 7 k 34.0 , 2 2''//562/e Mailing Address: q !j 2 -A✓F 75( SJ/!�47- Contact Person: 7ot'v IM vS��v E -Mail Address: 'Dk %i 4 5 wn fl SN.Celvt... Contractor Registration Number: 77ic tit? $Zt 0 7 A 7 ARCHITECT OF RECORD . 7. All plans tnust.be wet stamped by Architect of Recor Company Name: Mailing Address Contact Person: E -Mail A a dress: ENGINE OF "RECORD - All plans must be wet stamped by Engineer of Recor Company Name: Mailing Address: Contact Person: E -Mail Address: Q:\ApplicationsWorms- Applications On Line1.1-2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh 4/ iii Mechanical hermit City 0 Project No. For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 25"..)- 30 L{ - Cl 0 1 Suite Number: Floor: New Tenant: El .... Yes ..No Day Telephone: 246 City � w� Fax Number: /5 7 7 State Zip - — > 33 u Z6 y State Zip 3/ Fs // 4o City State Zip Day Telephone: t/ ?S' W98- - 7 74/ Z Fax Number: V ?5 Expiration Date: 1/ — / S _ 2e'a 7 City Day Telephone: Fax Number: Zip City Day Telephone: Fax Number: State State Zip Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressors Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation FanS.Qnnected -Sing a Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater �Yo Ventilation System Stove 30 -50 HP /1,750,000 BTU Appliance Vent ..01*-------- Water Heater 50+ HP /1,750,000 BTU - -M - Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator -' - _ - �� "' - -___ Air Handling Unit <10,000 CFM Incinerator - Comm/Ind � Other Mechanical Equipment �- l472 � � V-4.7.-- mil►' Valuation of Project (contractor's bid price): $ y c g 1 Jd Scope of Work (please provide detailed information):. 'nv5/41r(- 51 / otlD 0 I7} /9" /Wio w� 416 ?CiP Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric ❑ Gas ... Other: Indicate type of mechanical work being installed and the quantity below; Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A H ED AGENT: Signature: Print Name: C1/4/1 Mailing Address: 7 - k) / 3 2 4J_ `3J -5 G % Sort: ' I Q:\Applications\Forms- Applications On Line\3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Date: / > 7 _ ?6a7 Day Telephone: a_-do — y/ 2 % - 7 3 3 City - 5 4' 25 7 Zip ry Date Application Accepted: V-,\-1-o 7 Date Application Expires: Staff Initials: we Page2of2 Parcel No.: 2523049015 Address: 960 INDUSTRY DR TUKW Suite No: Applicant: B & K TAYLOR Receipt No.: R07 -02865 Payee: CHARLES GILLETTE TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: WER Payment Date: 12/27/2007 03:04 PM User ID: 1655 Balance: $0.00 Amount Payment Check 4903 301.01 Account Code Current Pmts 000/322.100 301.01 Total: $301.01 Permit Number: M07 -293 Status: PENDING Applied Date: 12/27/2007 Issue Date: Payment Amount: $301.01 6531 12/27 9710 TOTAL 301.01 doc: Receiot -06 Printed: 12 -27 -2007 Proje • L:- 1- 71 ( 1 La IZ Type of Inspection: 1— 1 N 4 Address: — Date Called: Special Instructions: Date Wanted: a.m. p.m. Re C . , h t I (0 Phone No 7 V 3 ^ 59 5' kl 2 I ION NO. T A .Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 k 0'6 PERMIT NO. (206)431 -3670 El Corrections required prior to approval. COMMENTS: ��r ✓�� : ,S CLr t v)3 ts pector Date: 8. REINSPECTION FEE REQU ED. Prior o inspection. fee must be • r• QQ at 6300 Southcenter Blvd., Su ?e 100. t the schedule reinspection. 1 Reipt No.: (Date: ja: ; , _ 0;14. Proe i Aj LO p Type of Inspection: / Et N 4 I v Address: Date Called: Special Instruc ions: lo CI e V\ Date Wa ed: 7 1 Request r: Plnkisg. _ ?iii , INSPECTION RECORD Retain a copy with permit 1407-W-5 INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION a 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3 i COMMENTS: rnoke -?/P ;chic - I - tos& - 7 - 0 0/N tic4rce c Air" r Date:' a & Jet, kJ LJ 0 REINSPECTION FE REQUIRED. Pr or to inspection. fee must be d at 6300 Southcenter lvd., Suite 1 O0.flaLt the schedule reinspection. 'Receipt No.: 'Date: Approved per applicable codes. Corrections required prior to approval. 4 Proj __ , Zfild & ect: / 4y /ii> Type )nspection: i ' 1- / ( Addresk fJ 7 Date Called: — Special Instructions: ,/_).-- Date Wanted: ' . - ffi Requester: Phone No: INSPECTION RECORD Retain a copy with permit 'i)7 7 15 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 COMMENTS: 7/A/4 d —10 ryfelfSS ID Approved per applicable codes. Corrections required prior to approval. J 5 AO REINSPECTION FE R UIRED. Prior to inspection, fee must be Id at 6300 Southcenter BLvd.. Suite 100. all the schedule reinspection. !Receipt No.: 'Date: Proj ect !� /44/ Ty Inspection // J 1. 'A/06✓�� �/ � j ` Date Called: Special Instructions: Date Wanted: .� a(- a.m. p.m. Requester: Phone No: _ 7y3 --- 55'i VI Approved per applicable codes. /7V 7253 INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 So Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: ns pector: Date: REINSPECTION FEE R = UIRE ' . Prior to inspection. fee must be t 6300 Southcenter Blv'., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Pro' t:4 / /! Ty�°f Inspection: ` /),01 S /l j17/,1'DWrl Addr ss: 56 .2A O'4,s4 L - Date Called: Special Instructions: Date anted: Zi 6/ ` a.m. p.m. Requester: P yzs -7 Y -5 INSPECTION RECORD Retain a copy with permit INSP ION NO. CITY OF TUKWILA BUILDING DIVISION �. 630 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Ayo4 - // � ,9ev.ew4/ � y Date: $ .00 REINSPECTION 1`EE R UIRED. Prior to inspection, fee must be • aid at 6300 Southcenter Blv .. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Prod �- Type of Inspecti n: cl 0 1 ASIi % 1'f • 1 Date Called: Special Instructions: Date Wanted: /— 3 / — O C Requester: Phone No: /1/G 724'5' INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Date/ 3/— dzr .00 REINSPECTIOM FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: / Id P Type of�DSPecg n: It/ / A res �� Date Called: Instructions: \n, 16L- 67.C\ r " t Date Wanted: /_3 / - d Special am p; Requester: Phone No: x/75 -7 g — q c INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 M Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: / —.3i of t 0 REINSPECTION FE REQU1fZ2ED. Prior to inspection, fee mist be OW at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: 6AK- 1 for Type of Inspection: •c A!Y1 D me- Address: %a 7 . L J ft 7 A Ale Date Called: Special Instructions: / t ro Date Wanted: /— 75 Jr a.m. e74.m. Requester: Phone No: ed 'cab! 14d7- 213 INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36k0 . U' 1 Corrections required prior to approval. ij \f)\ El S58.00 REINSPECTION FEE EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: t I( ,Z ;(( Al( 7 0 ri L- ___, , ,_,, -,---,„ Ai ,„_,1 bu •( 4k ii t r . J71- !' Date: t — 2S j ( ) Project: a sl/� ; .� yzo,e Type of Ins section: , / Address: D q 6' _Z.-A/ 194S7'g ate Called: Special.lnstructions: Date Wanted: a. Requester: Phone No: 4 /2-5 - 793 - ggC 7 ' 1 3 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION A 6300 Southce Blvd., #100, Tukwila, WA 98188 (206)431 -36 INSPECTION RECORD Retain a copy with permit 0 Approved per applicable codes. (121 Corrections required prior to approval. COMMENTS: Or./ elk/ .7 - /- /7 f , Q l(' F N ,wee 61,4-/AA ti/f 00 REINSPECTION F E REQUIRt=D. Prior to inspection, fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: `Project: 'g 4 4 - U01 Type of Inspection: Address: 9 (00 Suite #: Lt a\A 2i( Contact Person: j 2 1.._0v?_ Special Instructions: Occupancy Type: T Phone No.: ti-7 s - ?5Z- 0 I S 2 Needs Shift Ins ection: r;s se a - c _ r9 Sprinklers: //o Fire Alarm: Hood & Duct: 5/d 4-6-f W Monitor: Pre-Fire:; UNt — Permits: Occupancy Type: T ) CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 INSPECTION NUMBER .Approved per applicable codes. INSPECTION RECORD Retain a copy with permit rnoA - Z O7- f- ilU PERMIT NUMBERS n Corrections required prior to approval. COMMENTS: - t7N () F - I to 0,4 s /z ; /63 -Inspector: L- / , C 7 80.00 REINSPECTION FEE REQUIRED. You will r � Q receive an invoice from W, City of Tukwila Finance Department. Call to schedule a reinspection. Date: ( / v 9 - Hrs.: Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Item #1 FILE COPY CONSULTANTS MANUFACTURERS' AGENTS NORTHWEST, INC. 2310 . . . ITE B2 Date: Project Name: Permit #: Plan review: Re: Building Division Review Memo EVERETT, WASHINGTON 98204 • TOLT FRE TOLL FREE FAX: 1.877.318.1'185 ' 02 -27-07 B & K TAYLOR M07 -029 Allen Johannessen, Plans Examiner [IP(() 1% iL73 "Please identify use and occupancy for this tenant space. Explain what kind of business and /or operation that will be conducted in this tenant space. (IBC Section 302, Table 302.1.1)" [F] 307.5 High- Hazard Croup H -3. Buildings and structures that contain materials that readily support combustion or pres- ent a physical hazard shall be classified as Group H -3. Such materials shall include, but not be limited to, the following: Class 1, II or IIIA flammable or combustible liquids which are used or stored in normally closed containers or systems pressurized at less than 15 psi (103 kPa) gage. Combustible fibers Consumer fireworks, 1.4G (Class C Common) Cryogenic fluids, oxidizing Flammable solids Organic peroxides, Classes II and 111 Oxidizers, Classes 1 and 2 Oxidizing gases Unstable (reactive) materials, Class 2 Water- reactive materials. Class 2 RECEIVED DEC 27 2007 PERMIT CENTER B &K Taylor/ Wholesale Sign Solutions produces Sign materials, Computer generated banners, Retail sign production. http; //www. whol esalesignsolutions .com /index.html A portion of this facility will be producing and painting Foam letters used in Retail & Commercial Signage. " 1 "EFFICIENT EQUIPMENT SOLOUTIONS" SPRAY & METERING SYSTEMS, SUPPLY & TRANSFER PUMPS, SPRAY BOOTHS, OVENS & r+tR POLLU I I ,,'s CONTROL Item #2 "Please identify or name adjoining rooms for this space and identify adjoining tenant business or occupancies. (IBC 106.1.1)" Please see red, "Clouded" notation on page A02. The adjoining tenant space on the East side of B &K Taylor is currently vacant The adjoining tenant space on the West side of B &K Taylor is split into 2 sections. The Southern section with the roll up door is vacant. The front section which consists of a small office has a tenant, Mac Systems Inc. 962 Industry Drive, Tukwila, WA 98188 206 - 574 - 0001 Item #3 "The spray booth specifications shown on the plans shall require some additional information. Provide manufacturers specifications and details for the construction of the spray booth including material specifications. In addition please explain the reason for the two hour wall assembly and identify the total coverage for the two hour wall. (IBC Section 416)" All Spray Systems Spray Booth information is listed on Page A01 under "SPRAY SYSTEMS STD. DESIGN FEATURES" and listed on the drawing details on Page A02. The 2 hour "Firewal "as shown on Page A02 is to approve locating the spray booth against the Back, outside wall; as well as tight against the interior separation wall. (IBC Table 302.3.2) (IFC 1504.1.2.5) Although the table shows the requirement for a 1 hour wall we use the 2 hour as our standard to exceed safety codes depending on final "H" Occupancy determination. 1504.1.2.5 Clear space. Spray booths shall be installed so that all parts of the booth are readily accessible for cleaning. A clear space of not less than 3 feet (914 mm) Page 2 shall be maintained on all sides of the spray booth. This clear space shall be kept free of any storage or combusti- ble constriction. Exceptions: 1. This requirement shall not prohibit locating a spray booth closer than 3 feet (914 nun) to or di- rectly against an interior partition. wall or floor /ceiling assembly, that has a fire- resis- tance - rating of not less than 1 hour. provided the spray booth can be adequately maintained and cleaned. Item #4 2. This requirement shall not prohibit locating a spray booth closer than 3 feet (914 mm) to an exterior wall or a roof assembly provided the wall or roof is constructed of noncombustible material and provided the spray booth can be adequately maintained and cleaned. "Please provide additional building information that describes the type of construction. Identify if the building is sprinkled (IBC 106.1.1) The existing, multi- tenant building is of Concrete, tilt -up construction. Tenant spaces are separated by conventional Stud and sheetrock separation walls. The building is not sprinklered. The required fire suppression system for the paint spray booth is being provided, installed and permitted through "Alpine Fire & Safety Systems, Inc., 735 E. Fairhaven, Burlington, Wa. 98233. 360 755 - 5444. Stephen Bounds/President, UNDER SEPARATE COVER. Item #5 "Identify location for storage or containment areas for paint supplies and where quantities shall meet storage requirements. (IBC 414.1.2.1 & 414.2) Paint storage will be in approved "Flammable storage" cabinets" located at the North end of the Spray Booth. Actual quantity of coatings will be approximately 60 gallons. Please see red, "Clouded "notation on page A02 The type of cabinet that will be used is pictured below. Page 3 MATERIAL CLASS GROUP WHEN THE MAXIMIAI QUANTITY IS EXCEEDED STORAGE' USECLOSED SYSTEMS' usE - OPEN SYSTEMS' Sale pounds (cubic Meg Up/ Id gallons (pounds) (cubk WI al RIP) Sold pound* (ctiN*Wn LMMW gallons (pounds) (noble hst al NIP) Solid pounds loot*WI) Liquid gallons Ipounds) 11 H -2 or H -3 120 1217' Of Com liqu id' 1 UA H -2 01 H -3 N/A 33tl' NIA N/A 3317' N/A N/A 00' 11111 N/A 13201f' 13.2017 3.31■1' Cmmbuaihle filter Luse Baled H -3 I IpN iLINlOi N/A N/A f 1110 Il,f i N/A N/A 1241 iL1N1 NIA Consumer lmvurks (Class C. Common/ 1.46 H.3 125 N/A NIA N/A N/A N/A NIA N/A CryOpcnk-o flammable N/A 11-2 N/A 45 N/A N/A 45' N/4 N/A 110 C,ytipcni.. N /A___ NIA 451 N/A 45° N/A N 10 ___ Explosives Division 1.1 I' II °r '. - 0.25 1 ,0.25,' N/A 4.25 -._.._ 01.2 Do. i Sit m 1.2 I` fIf^ 4.25: 10.251 N/A x._51 (0.254' lab ision 1.3 S 5'1 254. 3 11 2144 WA I/ (1 Devisi,m 1.4 50'-s 1501'.• 50' t500' N/A N/A NeA Division I.4G 425x N/A N/A N/A N/A N /.4 N/A Division 1.5 1 11 f 0.25! 40.25K NIA 0.254 !0.25)5 Division 1.6 Ice s N/A N/A N/A N/A N/A N/A Gaseous W4 1.11(0 WA 1.4 Fl mable gas m liquefied 11.2 N/A iR'.. WA N/A 34.1'.. N[4 N/A N/A Flammable u liquid' IA IB and IC H -2 or H-3 N/A 30' 120 N /.4 1' 31* l_rw NIA N/A 1171 00 Combination O,imnwbk liquid 1 IA. IB. ICI N/A H2 or H -3 N/A (20 WA N/A 12(1' N/A N/A .10" Flammable solid N/A H -3 125 WA N/A 125' N/A N/A 25' N1A UL, I`'' 11)`- 333333 0,25 (0.251' N/A 0.254 (1)23,' 1 5" iSY" 1 211 N/A I. 11 )' Organic xiec 1'a<'' 11 111 ii 511 12 - ' 150' (1251 511" - 125' (51' ((257' N/A N/A DIM 25 Il4)' 05 IV NL NL N/L N/L N/A NI. NL v NL NL N/L. N/L ' N /.4 NL NI. 4 H -1 I°.' 114•' N/A 4.'54 211.251' N/A 0.25 14.251` Oxidizer 3s 2 H -2 H - 3 111 251'.` 11111 125 N/A N/A 2' 2510 (21' (2500' N/A N/A 2° NO ( 2)' 15111^ 1 ii-3 4.0110'.' (13XI11f' 041,1 43041' (4.01001' N/A 1.0 00' i 1,00i Gaseous N/A WA 1.503" N/A N/A 151X0 • WA NIA Oxidizing gas liquefied H -3 N/A 15" N/A N/A j5" N/A N/A N/A 49 TABLE 707.7(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD (onlitmedi Page 4 1 „PC' MATTHEWS PAINT Matthewg Py�ergihan •. c ,,+ to � �73 + t _ }} � tt( . l., mi sect l..:7) C:1:.1 C!Z't ..�Gl� ^ ". M MAP (Matthews Acrylic Polyurethane) is famous for its ability to withstand exposure to - extreme climatic conditions. MAP'S highly durable, chemically cross - linked coating allows most graffiti to be easily wiped off with a suitable solvent. MAP provides excellent exterior durability over metal, wood and numerous plastics. MAP has an unlimited selection of standard and custom colors in gloss to matte finishes. Color offsets to any manufacturer are also available. Features: • Extremely hard, yet flexible film • Air dry or bake • Great UV resistance Compatible Surfaces: MAP® Acrylic Polyurethane may be applied over: 6001SP Polyester Primer Surfacer 6010SP Flexible Sealer 6013SP Black Epoxy Primer 274 228SP E Prime White 2.8 274 685SP/274 686SP U Prime 274 908SP/274 909SP White Epoxy Primer Required Products: Catalyst 43 270SP Universal Catalyst Permit No. FILE COPY Benefits: 43 333SP Suede Catalyst (For a textured appearance) 43 621SP Brushing Catalyst (For brush or roller application) 43 999SP Slow Catalyst (For hot weather or bake application) Product Information Effective 10/05 • High impact, mar and abrasion resistant • Excellent chemical and corrosion resistance • Fits most shop conditions • Excellent gloss retention 74 734SP/74 735SP Metal Pretreatment 74 760SP/74 766SP PT Filler 74 770SP/74 766SP HBPT 74 780SP/74 781SP HBEF 74 777SP Tie Bond 74 793SP Spray Bond Reducers (Conventional) 45 251SP Retarder JAN - 7 t.1jt 1f mpg , Natural White Slane natural Blanco natural 6379SP Cool temperature, 60 - 75 ° F (16 - 24 °C) 45 280SP Warm temperature, 70 - 80 °F (21 - 27 ° C) 45 290SP Very warm temperature, 75 - 85 (24 - 29 ° C) 6396SP Hot temperature, 80 °F (27 °C) & above C f DEC 2 °7 CtJU1 PERMIT GE N {.: MAP® Directions for Use Surface Preparation: Mix Ratio: Reducers: Additives: [l:fl LI IA B Spray Set Up: Substrate should be prepared according to undercoat instructions prior to topcoat application. Mix Ratios (by volume) MAP MAP Catalyst* Map Reducer ** 3 parts 1 part 1 part * Catalysts that can be used in any MAP topcoats at a 3:1:1 ratio are: 43 270SP Universal Catalyst 43 999SP Slow Catalyst (For hot weather or bake application) 43 333SP Suede Catalyst (For a textured appearance) NOTE: If brushing or rolling is required, 43 621SP Brushing Catalyst is recommended at a ratio of six (6) parts paint to one (I) part catalyst to two (2) parts B/R Additive 47 444SP @ (6:1:2) mix ratio. ** Choose MAP reducer best suited for shop conditions • MAP color, catalyst and reducer should be mixed in thoroughly before using. • Mix no more material than will be used in an 8 -hour period. • Spray viscosity should be 18 - 22 seconds ( #2 Zahn cup). • Strain material following mixing. • Pot life of mixture is 8 hours at 70 °F (21°C), or 2 hours w/ 287 437SP accelerator. MAP Reducers (Conventional): 6379SP Cool temperature, 60 - 75 ° F (16 - 24 °C) 45 280SP Warm temperature, 70 - 80 °F (21 - 27 ° C) 45 290SP Very warm temperature, 75 - 85 ° F (24 - 29 ° C) 6396SP Hot temperature, 80 °F (27 °C) & above 45 251SP Retarder None required, but the following may be used for specific application or project needs: 287 437SP Accelerator 287 113S Suede Additive 47 444SP Brush /Roller Additive 47 333SP Anti- Crater Solution SOA 950SP Gloss Modifier SOA 955SP Matting Clear (Note: This is a flattening paste and cannot be used as a topcoat) Air Pressure: Gun Set Up: Page 2 MPC100 Conventional: HVLP: Pot Pressure: Siphon Feed: HVLP: Pressure Pot: 47 888SP Flattening Paste 74 102SP MAP Converter 74 103SP Slow Converter 47 474SP Flex Additive 40 - 50 psi at the gun 10 psi at the cap 10- 12 psi 1.4 mm 0.055 fluid tip 1.4 mm 0.055 fluid tip 1.2 mm 0.046 fluid tip Directions for Use Application: Factory Pack Colors: Drying Times: Equipment Cleaning: 41 306SP 41 312SP 41 313SP 41 314SP 41 335SP 41 342SP 42 202SP 42 204SP 42 212SP 42 214SP Apply: Recommended Dry Film Thickness: 2 mils minimum (DFT) Note: Finish with a medium to light final coat for metallic control. Caution: All 2 component cross - linking stops or slows significantly at temperatures below 60 °F or 16 °C. Never spray or subject freshly painted coatings to these conditions or loss of gloss, poor water and chemical resistance, decreased durability and improper curing will occur. Signal Jet Black Medium Bronze Dark Bronze Old Copper Anodic Black Brushed Aluminum Natural White Gloss Black Scarlet Red Mexicali Red *These colors require the use of a dear coat for exterior application. Air Dry (50% relative humidity, 70°F / 21 °C) Dust Free Tack Free Tape Timc Dry to Handle Dry to Clearcoat Bake Dry with 43 999SP Slow Catalyst Allow 10 - 15 minutes flash before baking to prevent solvent popping 60 minutes @ 150 °F / 66 °C 30 minutes @ 200 °F / 93 ° C 10 minutes @ 300 °F / 149 Temperatures over 350 / 177 ° C should be avoided. Note: Paint films cured over 24 hours should be li tl dry scuff sanded with 320 - 400 grit by hand/machine or 600 wet grit sanded before recoating to assure proper adhesion. Clean up equipment promptly with 45 340SP Cleans -It or an all- purpose clean up solvent. Do not leave mixed material in equipment. Page 3 MPC100 1 full wet coat Flash 5 - 10 minutes between coats Follow with a second full wet coat Apply additional coats as necessary to achieve total dry film thickness. 42 215SP 42 218SP 42 219SP 42 259SP 46 253SP 46 258SP 46 400SP 46 401SP 46 402SP 6422SP Burgundy Maroon Sundance Yellow Capri Blue Federal Green Copper Gold Brilliant Gold over MP18645 Basecoat* Aztec Gold over MP34132 Basecoat* Aztec Copper over MP32759 Basecoat* Gloss Hi -Hide White Without Accelerator 15 minutes 2 hours 16 hours 24 hours 30 min. With 287 437SP Accelerator 15 minutes 1 hour 2 - 4 hours 4 hours 15 minutes MAP® Technical Data: Important: EMERGENCY MEDICAL OR SPILL CONTROL INFORMATION - US (412) 434 -4515; CANADA (514) 645 -1320; MEXICO 01- 800 -00 -21 -400 Materials described are designed for application by professional, trained personnel using proper equipment and are not intended for sale to the general public. Products mentioned may be hazardous and should only be used according to directions, while observing precautions and warning statements listed on label. Statements and methods described are based upon the best information and practices known to Matthews Paint. Procedures for applications mentioned are suggestions only and are not to be construed as representations or warranties as to performance, results, or fitness for any intended use, nor does Matthews Paint warrant freedom from patent infringement in the use of any formula or process set forth herein. If you require technical assistance, please call us toll -free 800/323 -6593. mpc4; MATTHEWS PAINT See Material Safety Data Sheet and Labels for additional safety Information and handling instructions. The contents of this package may have to be blended with other components before the product can be used. Before opening the packages, be sure you understand the warning messages on the labels of all components, since the mixture will have the hazards of all its parts. Improper spray technique may result in a hazardous condition. Follow spray equipment manufacturer's instructions to prevent personal injury or fire. Follow directions for respirator use. Wear eye and skin protection. Observe all applicable precautions. The World's Finest Coating For Architectural Signage LakeView Corporate Park • 8201 - 100th Street Pleasant Prairie, WI 53158 -2201 Toll Free: 800/323 -6593 • Wisconsin: 262/947 -0700 Toll Free FAX: 800/947 -0377 • FAX: 262/947 -0444 Matthews Acrylic Polyurethane VOC Information MAP 4.3 - 5.0 MAP Catalyst 5.3 - 5.8 MAP Reducer 7.3 - 8.0 Ready to Spray (3:1:1) 5.0 - 5.5 Performance Characteristics Volume solids 33% - 43% Volume solids (RTS) 25% - 31% Theoretical Coverage (1 mil @ 100% transfer efficiency) 500 sq.ft. /RTS gal. Application Conditions 60 °F (16 °C) Minimum 100 °F (38 °C) Maximum Relative Humidity 85% maximum 5° above dew point Gloss Matte - High Flash Point (Tag closed cup) Below 80 °F (27 °C) © 2005 Matthews Paint Company www.signpaint.com or www.matthewspaint.com Part No. MPC100 10/05 \0 mpe MATTHEWS PAINT Matthews Acrylic Polyurethane Satin MAP incorporates the same quality perform of MAP® but in a uniform satin finish. Satin MAP produces a "Satin -in -the -Can" gloss level that is compliant with the Americans with Disabilities Act (ADA). Ideal substrates include signage components, graphic arts and architectural metals. Satin MAP is also suitable for use on metal, wood and various plastics. Satin MAP is available in standard colors plus an unlimited selection of custom colors. Features: • Satin -in -the -Can • Acrylic Polyurethane Compatible Surfaces: Satin MAP® Acrylic Polyurethane may be applied over: 6001SP Polyester Primer Surfacer 6010SP Flexible Sealer 6013SP Black Epoxy Primer 274 228SP E Prime White 2.8 274 685SP/274 686SP U Prime 274 908SP/274 909SP White Epoxy Primer Required Products: Catalyst ati 43 270SP Universal Catalyst 43 333SP Suede Catalyst (For a textured appearance) FILE COPY 43 621SPBrushing Catalyst (For brush or roller application) 43 999SP Slow Catalyst (For hot weather or bake application) Product Information Effective 10/05 MATTHEWS PAW CIAITY WNh 6425SP k �si . 'boo P No busolocl to errors and a� Matthews Acres I dl iut' t . - _ ,•,-' ? atth Benefits: • No flattening agent needed • Uniform color and finish • Weather & Chemical Resistant • Long -term Durability 74 734SP/74 735SP Metal Pretreatment 74 760SP/74 766SP PT Filler 74 770SP/74 766SP HBPT 74 780SP/74 781SP HBEF 74 777SP Tie Bond 74 793SP Spray Bond Reducers (Conventional) O i L.��+k. 1 JAN '° r ?o c M0"7 293 RECEIVE!) DEC 2 7 2007 PERMIT CENTEI` 6379SP Cool temperature, 60 - 75 ° F (16 - 24 °C) 45 280SP Warm temperature, 70 - 80°F (21 - 27 °C) 45 290SP Very warm temperature, 75 - 85 (24 - 29 °C) 6396SP Hot temperature, 80°F (27 °C) & above 45 251SP Retarder Reducers: Additives: Satin MAP Directions for Use Surface Preparation: Mix Ratio: • Spray Set Up: + Il:fl LI Os H1/4% Substrate should be prepared according to undercoat instructions prior to topcoat application. Mix Ratios (by volume) Satin MAP MAP Catalyst* Map Reducer** 3 parts 1 part 1 part * Catalysts that can be used in any MAP topcoats at a 3:1:1 ratio are: 43 270SP Universal Catalyst 43 999SP Slow Catalyst (For hot weather or bake application) 43 333SP Suede Catalyst (For a textured appearance) NOTE: If brushing or rolling is required, 43 621SP Brushing Catalyst is recommended at a ratio of six (6) parts paint to one (1) part catalyst to two (2) parts B/R Additive 47 444SP @ (6:1:2) mix ratio. ** Choose MAP reducer best suited for shop conditions • SATIN MAP color, catalyst and reducer should be mixed in thoroughly before using. • Mix no more material than will be used in an 8 -hour period. • Spray viscosity should be 18 - 22 seconds ( #2 Zahn cup). • Strain material following mixing. • Pot life of mixture is 8 hours at 70 °F (21 °C), or 2 hours w/ 287 437SP accelerator. MAP Reducers (Conventional: 6379SP Cool temperature, 60 - 75 °F (16 - 24 °C) 45 280SP Warm temperature, 70 - 80 °F (21 - 27 °C) 45 290SP Very warm temperature, 75 - 85 °F (24 - 29 °C) 6396SP Hot temperature, 80 °F (27 °C) & above 45 251SP Retarder None required, but the following may be used for specific application or project needs: 287 437SP Accelerator 47 888SP Flattening Paste 287 113S Suede Additive 74 102SP MAP Converter 47 444SP Brush/Roller Additive 74 103SP Slow Converter 47 333SP Anti-Crater Solution 47 474SP Flex Additive SOA 950SP Gloss Modifier SOA 955SP Matting Clear (Note: This is a flattening paste and cannot be used as a topcoat) Air Pressure: Gun Set Up: Page 2 MPC102 Conventional: 40 - 50 psi at the gun HVLP: 10 psi at the cap Pot Pressure: 10 - 12 psi Siphon Feed: 1.4 mm 0.055 fluid tip HVLP: 1.4 mm 0.055 fluid tip Pressure Pot: 1.2 mm 0.046 fluid tip Directions for Use Application: Factory Pack Colors: Drying Times: Equipment Cleaning: • Apply: 1 full wet coat Flash 5 - 10 minutes between coats Follow with a second full wet coat Apply additional coats as necessary to achieve total dry film thickness. Recommended: Dry Film Thickness: 2 mils minimum (DFT) Note: Finish with a medium to light final coat for metallic control. Caution: All 2 component cross - linking stops or slows significantly at temperatures below 60°F or 16 °C. Never spray or subject freshly painted coatings to these conditions or loss of gloss, poor water and chemical resistance, decreased durability and improper curing will occur. 6425SP Satin Hi -Hide White 41 335SP Anodic Black Air Dry (50% relative humidity, Without With 287 437SP 70 °F / 21 °C) Accelerator Accelerator Dust Free 15 minutes 15 minutes Tack Free 2 hours 1 hour Tape Time 16 hours 2 - 4 hours Dry to Handle 24 hours 4 hours Dry to Clearcoat 30 min. 15 minutes Bake Dry with 43 999SP Slow Catalyst Allow 10 - 15 minutes flash before baking to prevent solvent popping 60 minutes @ 150 °F / 66 °C 30 minutes @ 200 °F / 93 °C 10 minutes @ 300 °F / 149 °C Temperatures over 350 / 177 °C should be avoided. Note: Paint films cured over 24 hours should be lightly dry scuff sanded with 320 - 400 grit by hand/machine or 600 wet grit sanded before recoating to assure proper adhesion. Clean up equipment promptly with 45 340SP Cleanz -It or an all- purpose clean up solvent. Do not leave mixed material in equipment. Page 3 MPC102 Satin MAP® Technical Data: Impo Matthews Acrylic Polyurethane VOC Information Satin MAP 4.3 - 4.7 MAP Catalyst 5.3 - 5.8 MAP Reducer 7.3 - 8.0 Ready to Spray (3:1:1) 5.3 - 5.5 Performance Characteristics Volume solids 33% - 43% Volume solids (RTS) 25% - 31% Theoretical Coverage (1 mil @ 100% transfer eiciency) 500 sq.ft. /RTS gal. Application Conditions 60 °F (16 °C) Minimum 100 °F (38 °C) Maximum Relative Humidity 85% maximum 5 above dew point Gloss Satin 15° - 20° w /60° meter Flash Point (Tag closed cup) Below 80 °F (27 °C) The contents of this package may have to be blended with other components before the product can be used. Before opening the packages, be sure you understand the warning messages on the labels of all components, since the mixture will have the hazards of all its parts. Improper spray technique may result in a hazardous condition. Follow spray equipment manufacturer's instructions to prevent personal injury or fire. Follow directions for respirator use. Wear eye and skin protection. Observe all applicable precautions. See Material Safety Data Sheet and Labels for additional safety information and handling Instructions. EMERGENCY MEDICAL OR SPILL CONTROL INFORMATION - US (412) 434 -4515; CANADA (514) 645 -1320; MEXICO 01- 800 -00 -21 -400 Materials described are designed for application by professional, trained personnel using proper equipment and are not intended for sale to the general public. Products mentioned may be hazardous and should only be used according to directions, while observing precautions and warning statements listed on label. Statements and methods described are based upon the best information and practices known to Matthews Paint. Procedures for applications mentioned are suggestions only and are not to be construed as representations or warranties as to performance, results, or fitness for any intended use, nor does Matthews Paint warrant freedom from patent infringement in the use of any formula or process set forth herein. If you require technical assistance, please call us toll -free 800/323 -6593. :mpe MATTHEWS PAINT The World's Finest Coating For Architectural Signage LakeView Corporate Park • 8201 - 100th Street Pleasant Prairie, WI 53158 -2201 Toll Free: 800/323 -6593 • Wisconsin: 262/947 -0700 Toll Free FAX: 800/947 -0377 • FAX: 262/947 -0444 ® 2005 Matthews Paint Company www.signpaint.com or www.matthewspaint.com Part No MPC102 10/05 ACTIVITY NUMBER: M07 - 293 DATE: 12 - - PROJECT NAME: • B & K TAYLOR SITE ADDRESS: 960 INDUSTRY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTM NTS: 40D B Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01 -03 -08 Complete g Division Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 ttRMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention ❑ Planning Division Structural ❑ Permit Coordinator Incomplete Structural Review Required Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 01 -24 -08 DATE: Approved ❑ Approved with Conditions E Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License THOMAII072P9 Licensee Name THOMAS INDUSTRIES INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601481965 Ind. Ins. Account Id 91165007 Business Type CORPORATION Address 1 20942 NE 78TH ST Address 2 City REDMOND County KING State WA Zip 98053 Phone 2062840486 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/29/1993 Expiration Date 10/15/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HANSEN, THOMAS J Cancel Date 01/01/1980 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expirarion Date Cancel Date Impaired Date Bond Amount Received Date #4 CBIC SB1581 10/01/2001 Until Cancelled $12,000.00 10/15/2001 #3 CBIC SB1581 10/01/1997 10/01/2001 $6,000.00 STAR INS r -- - - --- ----- - Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. a wbv a va— https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= THOMAII072P9 01/09/2008 r 1 0' 0 15' WIDE DRAINAGE & UTILITY EASEMENT 1 NO1 4728 "E 18.00 03 CC 0 N 15' WIDE -t- UTILITY • EASEMENT ( LI 0 L 10 BLDG. 28 >° 23,858 SO- FT PARCEL 1 rn • 31 2 a 0 ! 1 50' WIDE SETBACK I LEGAL DESCRIPTION -•I 2.5 a 15' WIDE SETBACK _53 15' WIDE SETBACK SITUATED IN THE SOUTHWEST QUARTER OF SECTION 25, TOWNSHIP 23 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, CITY OF TUKWILA, KING COUNTY, WASHINGTON, AND BEING DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE CENTERLINE OF A PRIVATE ROAD, ALSO KNOWN AS INDUSTRY DRIVE, SAID POINT BEING SOUTH O1 ° 47'28 - WEST, A DISTANCE OF 90.48 FEET AND SOUTH 88 EAST, A DISTANCE OF 127.16 FROM THE WEST QUARTER CORNER OF SAID SECTION 25 AND RUNNING THENCE SOUTH 88 ° 12'32" EAST, A DISTANCE OF 291.50 FEET TO A POINT ON THE WEST RIGHT -OF -WAY LINE OF JAMES CHRISTENSEN ROAD NO. 1479; THENCE FOLLOWING SAID WEST RIGHT -OF -WAY LINE THE FOLLOWING COURSES: SOUTH 32 ° 39'25" WEST, A DISTANCE OF 96.43 FEET; THENCE SOUTH 20 4 16'25' WEST, A DISTANCE OF 114.09 FEET; THENCE SOUTH 03 ° 06'25" WEST A DISTANCE OF 122.73 FEET; THENCE SOUTH 02 EAST, A DISTANCE OF 98.54 FEET; THENCE SOUTH 19 4 53'35' EAST, A DISTANCE OF 168.86 FEET; THENCE SOUTH 32'38'35' EAST, A DISTANCE OF 158.24 FEET; THENCE SOUTH 44 ° 38'35" EAST, A DISTANCE OF 25.37 FEET TO A POINT; THENCE LEAVING SAID WEST RIGHT -OF -WAY LINE AND RUNNING SOUTH 01 4 47'28" WEST, A DISTANCE OF 461.42 FEET; THENCE NORTH 8812'32' WEST, A DISTANCE OF 254.00 FEET TO A POINT ON THE EAST TERMINUS LINE OF MINKLER BLVD.; THENCE NORTH 01 EAST, ON SAID TERMINUS LINE A DISTANCE OF 18.00 FEET TO THE NORTHEAST CORNER OF SAID MINKLER BLVD. AND BEING ON THE NORTH RIGHT -0I -WAY LINE THEREOF, SAID POINT ALSO BEING 45.00 FEET FROM THE CENTERLINE; THENCE NORTH 88 4 12'32" WEST, ON SAID NORTH RIGHT -OF -WAY LINE A DISTANCE OF 103.00 FEET TO A POINT ON THE CENTERLINE OF A PRIVATE DRIVE THENCE ON SAID CENTERLINE THE FOLLOWING COURSES: NORTH 01 EAST, A DISTANCE OF 430.00 FEET TO THE BEGINNING OF A TANGENT 250.00 FOOT RADIUS CURVE LEFT; THENCE ON SAID CURVE THROUGH A CENTRAL ANGLE OF 17 (THE LONG CHORD OF WHICH BEARS NORTH 07 ° 0719' WEST, A DISTANCE OF 77.47 FEET) AN ARC DISTANCE OF 77.78 FEET TO THE END THEREOF AND THE BEGINNING OF A TANGENT 250.00 FOOT RADIUS CURVE RIGHT; THENCE ON SAID CURVE THROUGH A CENTRAL ANGLE OF 17 (THE LONG CHORD OF WHICH BEARS NORTH 07 ° 0719" WEST, A DISTANCE OF 77.47 FEET) AN ARC DISTANCE OF 77.78 FEET TO THE END THEREOF; THENCE NORTH 01 EAST, A DISTANCE OF 577.17 FEET TO THE POINT OF BEGINNING, CONTAINING 7.783 ACRES MORE OR LESS. 1 BASIS OF BEARING BEING THE CENTERLINE OF STRANGER BLVD. PER SURVEY NO. 8704029002. N01'4 7'28 - E 430 00 0 a0 - 301'47 . 28"W 461 42 16 20' WOE INGRE & EGRESS EASEMENT 1 4 �y� --1 BLDG. 26 12.400 SQ FT ,. •i • �_j 95. • a fe z BLDG. 24 18,6;1 SG. C J 53 i- -= 50 UU A = 7 77 8 8= 507 0 77 47 G BLDG. 22 19 200 SO. FT -17'49' 33" R = 250.00 A 7778 C B =S0T07'19 - E C 77 47 S 7 V . 16 156TTM sT 4 s 1 4 - 3 as 11 17OTM 'ST 76T• ry 20 WIDE NON-EXCLUSIVE ACCESS EASEMENT sr f l INDUSTRY DRIVE VICINITY MAP LEGEND l5 20' WIDE INGRESS & EGRESS EASEMENT 351 'Pi 54 0 • .. "40Ni,MENT A; NC..rFO i rEC •IN; N„ r F • •_;w P1 A ",'ii •',gip rT 1 r'r E pM i1 gIN 1Ni 0; . --F tia ER !METER :1 V4UL T .j ., t+.9 T ER :4D +(aP P4RhlydL+ Pq:c Ear+GNE a ;c O t .*� ve - 11 r P(:ti1 r., IMF N 1" = 50' 50 25 0 50 100 3 R F • �. NCI 47'28 "E 57717 iO3'06•<5':v 122 73 SPRAY SYSTEMS STD. DESIGN FEATURES BOOTH CONSTRUCTION PANELS ARE MANUFACTURED OF 18 GA. GALVANIZED STEEL. ALL PANELS HAVE PREPUNCHED HOLES FOR EASY NUT & BOLT ASSEMBLY. BOTH THE FILTER AND SOLID TYPE DOORS HAVE A STRUCTURAL STEEL TUBE FRAME, LEAK PROOF WIPER TYPE SEALS AT THE BOTTOM & POLYFOAM SEALS AT THE CENTER & JAMBS. LIGHTING HIGH EFFICIENCY LIGHTING UNITS DESIGNED FOR MOUNTING OUTSIDE BOOTH. SET IN FRAMED WIRE GLASS OPENINGS, HAVE DUST TIGHT SEALS & ARE UL LISTED. FAN SPECIFICATIONS DESIGNED FOR SPRAY BOOTHS. HEAVY DUTY TUBEAXIAL TYPE WITH ENCLOSED BELTS & BALL BEARINGS. MOTORS ALL MOTORS ARE ENERGY EFFICENT, TOTALLY ENCLOSED, FAN COOLED, MULTIVOLTAGE, 2081230/460 THREE PHASE WITH SINGLE PHASE OPTION. FILTER GAUGE A MANOMETER INDICATES WHEN PAINT ARRESTORS OF INTAKE FILTERS REQUIRE REPLACEMENT. EXHAUST FILTERS DISPOSABLE PAINT ARRESTOR EXHAUST AIR FILTERS ARE A SPECIALLY SPUN FIBER DESIGNED TO REMOVE PAINT PARTICLES EFFICIENTLY FROM SPRAY BOOTH EXHAUST AIR. UL LISTED ELECTRICAL COMPONETS AND LATCHING DEVICES ARE UL LISTED. FIRE SUPPRESSION /SPRINKLER SYSTEM PERMIT WILL BE APPLIED FOR ATA LATER DATE BY THE DESIGN/BUILD INSTALLATION COMPANY. THIS WILL BEA DEFERRED SUBMITTAL kv 15' WIDE SETBACK GENERAL NOTES 15' WIDE SETBACK 4, 3 Li) r P.O.B. ALL SPRAY BOOTHS & MIXING ROOMS SHALL COMPLY WITH 2003 INTERNATION BUILDING CODE & ALL LOCAL CODES INCLUDING FIRE CODES. 1. CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS & MEASUREMENTS, ANY DISCREPANCIES FOUND CONTACT OWNER & OR DESIGNER IMMEDIATLY. 2. ELECTRICAL WIRING SHALL COMPLY WITH ICC WIRING CODE. 3. ALL METAL PARTS OF THE SPRAY BOOTH, MOTORS, EXHAUST DUCTS & PIPING SHALL BE ELECTRICALLY GROUNDED 4. ELECTRICAL WIRING & EQUIPMENT IN SPRAY BOOTH & VAPOR AREAS SHALL BE OF AN EXPOSION -PROOF TYPE FOR USE IN SUCH HAZORDOUS LOCATIONS. 5. OPEN FLAMES & SPARK - PRODUCING DEVICES SHALL NOT LOCATED ON SPRAY OR VAPOR AREAS & SHALL NOT LOCATED WITHIN 20 FT OF SUCH AREAS. 6. EQUIPMENT OR APPARATUS THAT IS CAPABLE OF PRODUCING SPARKS OR PARTICLES OF HOT METAL WOULD FALL INTO SPRAY BOOTH OR VAPOR AREA SHALL BE TOTALLY ENCLOSED. 7. SMOKING SHALL BE PROHIBITED IN SPRAY BOOTH OR VAPOR AREAS, "NO SMOKING" SIGNS SHALL BE CONSPICUOUSLY POSTED IN SUCH AREAS. 8. COMBUSTIBLE FLOOR IN SPRAYING AREAS SHALL BE COVERED BY APPROVED, NONCOMBUSTIBLE, NON SPARKING MATERIAL, EXCEPT WHERE COMBUSTIBLE COVERINGS, SUCH AS THIN PAPER OR PLASTIC AND STRIPPABLE COATINGS ARE UTILIZED OVER NONCOMBUTIBLE MATERIALS TO FACILITATE CLEANING OPERATIONS IN SPRAYING AREAS. 9. SPRAYS /SPRAY ROOMS & SPRAY AREAS SHALL NOT ALTERNATELY UTILIZED FOR DIFFERENT TYPES OF COATING MATERIALS WHERE THE COMBINATION OF MATERIALS IS CONDUCTIVE TO SPONANEOUS IGNITION, UNLESS ALL DEPOSITS OF ONE MATERIAL ARE REMOVED FROM THE BOOTH, ROOM OR AREA & EXHAUST DUCTS PRIOR TO SPRAYING WITH A DIFFERENT MATERIAL. 10. WHERE SPRAYING AREAS, SPRAY ROOMS OR SPRAY BOOTHS ARE ILLUMININATED THROUGH GLASS PANELS OR OTHER TRANSPARENT MATERIALS, ONLY FIXED LIGHTING UNITS SHALL BE UTILIZED AS A SOURCE OF ILLUMINATION. 11. SPRAY BOOTHS & MIXING ROOMS SHALL BE ANCHORED TO THE FLOOR AT LOCATIONS PROVIDED BY MANUFACTURE. 12. BOOTH EXHAUSTS SHALL EXHAUST 6 FT MIN ABOVE ROOF & 30 FT MIN FROM PROPERTY LINES. 13. MECHANICAL VENTILATION OF SPRAYING ARES SHALL BE PROVIED IN ACCORDANCE WITH INTERNATIONAL MECHANICAL CODE. 14. VENTILATION SHALL BE AMIN OF 30 FT FROM PROPERTY LINES & 10 FT FROM FROM OPENINGS INTO BUILDING, 6 FT FROM WALLS AND ROOFS. 15. A FIRE EXTINGUISHER, CLASS C, 4 -A SHALL BE PROVIDED WITHIN 75 i T MAX. SPRAY BOOTH SPEC.S 16. SPRAY SYSTEM SPRAY BOOTH IS BUILT IN ACCORDANCE WITH NFPA- 33,IFC, NEC, IBC, IMC. 17. THE SPRAY BOOTH IS CONSTRUCTED OF NO.18 GAUGE HOT DIPPED GALVANIZED STEEL. 18. EXHAUST FANS ARE TUBAXIAL WITH NON- SPARKING BLADE. FAN BELTS DO NOT ENTER THE HOUSING, DUCT OR BOOTH. 19. THE INTERIOR SURFACE OF THE SPRAY BOOTH WILL BE SMOOTH & CONTINUOUS WITH OUT EDGES. 20. LIGHT FIXTURES WILL BE 4 TUBE FLUORSCENT, OPEN TYPE SEALED FROM OUTSIDE OF THE SPRAY BOOTH BEHIND 114" SAFETY GLASS. 21. THE SPRAY BOOTH HAS A VISIBLE LIQUID DIFFERENTIAL AIR GAUGE (MANOMETER) FOR EXHAUST FILTER REPLACEEMNT WARNING. 22. THE EXHAUST FILTER PLENUM IS LOCATED ON THE BACK OF THE SPRAY BOOTH. THE EXHAUST FILTERS WILL COMPLY WITH CODE REQUIREMENTS N.F.P.A. 33, UNDERWRITERS, INC. (UL), ENVIORMENTAL AGENCY (EPA), SAFETY & HEALTH ASSOCIATION (OSHA STD. 1910.107. 23. EXHAUST DUCT IS MADE FROM 18 GAUGE GALVANIZED STEEL & COMPLIES WITH IMC. 24. THERE ARE NO BENDS IN THE EXHAUST DUCT GREATER THAN A 45- DEGREE ANGLE. 25. THE EXHAUST DUCT WILL HAVE A CLEAN OUT FOR CLEANING & INSPECTION. 26. COMPRESSED AIR TO OPERATE SPRAY EQUIPMENT INSIDE OF THE SPRAY BOOTH WILL BE INTERLOCKED WITH EXHAUST FAN, SPRAY EQUIPMENT WILL NOT OPERATE WITH OUT THE SPRAY BOOTH TURNED ON. 27. PLANS & SPECIFICATIONS FOR THE DESIGN & INSTALLATION OF THE FIRE SUPPRESSION SYSTEM WITHIN THE BOOTH WILL BE SUBMITTED BY OTHERS. FILE COPY it Permit No. , 142 Plan rlewis111► appnoraiIsatetoanamandanlissians. Approval of con$ U pladtvize the violation claw adopted code Or 0rdkrance. Receipt of approved adilvavdedged: EV 7 Da*, 1"" a City of Tukwila BUILDING DIVISION REV1SiONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: E: Revisions will require a new plan submittal and may include additional plan review fees. PROPERTY OWNER: CIO EPROPER T Y T Aid INC. 800 INDUSTY DR. TUKWILA, WASH. 98188 BUSINESS: WHOLESALE SIGN SOLUTIONS ADDRESS: 960 INDUSTRY DR. TUKWILA, WASH. 98188 PAGE DIRECTORY: SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical ie Electrical G Iurnbing as Piping City of I-i,t'P;:i. ER7U1Lr!f.'!Qt -? LEASING COMPANY: RREEF SR. LEASING PROP. MANAGER: CONNIE DOBBS 631 STRANDER BLVD., SUITE G TUKWILA, WASH. 98188 PHONE: 206 - 575 -0765 PARCEL NO.: 252304 -9015 PROPERTY DESCRIPTION: SEE PLOT PLAN ON PAGE A 01 PROJECT DESCRIPTION: 1. INSTALL A PAINT BOOTH. 2. NO CHANGES TO FOUNDATION, NO EXCAVATION REQ'D, NO CHANGES TO BLDG SPACE. 4. EXHAUST GOES STRAIGHT UP THRU ROOF & THEN ALONG ROOF TO A POINT THAT IS A MIN. OF 30' -0" FROM PROPERTY LINES AND A MIN OF 6' -0" ABOVE ROOF. 5. PAINT BOOTH, MIXING ROOM & AIR MAKE UP TO BE ATTACHED TO EXISTING CONCRETE FLOORS PER DETAIL 11 A 01 A 01 PLOT PLAN, PROPERTY DESCRIPTION, GENERAL NOTES, A cA DETAIL PLANS & SECTIONAL ELEVATION 4W. PROJECT PLAN Ariegiffiglikagrffnakfirra- RECEIVE D DEC 2 7 2007 PERMIT CENTER Mop - z93 1 1 0 0 Q Q CO cD LLI LL. CO CC Z � � Z n 0 . cD 7- W Z ix CC CC w p° U 1- x ti w m r .n G aC1 x 0) 0 0 w A01 0) cP 0) 0) c•� a w (DBL) 2x6 EACH SIDE OF CUT IN OPENING USE HUS26.2 HANGERS STD. ROOF PENTRATION DETAIL SCALE 1/4" =1 RAIN GUARD 22 GAUGE WRAPPER 2" AIR GAP MIN DUCT SEAL AT ROOF NO SCALE .1� DIA. PER PLAN EXHAUST DUCT NEW TORCH DOWN SEAL EXIST. ROOF BOLT HEAD w!WASHER 07116" HOLE � 1 30' -0" MIN DIST, TO PROPERTY LINES (1)STORM COLLAR (1)ROOF JACK FLAT (1)34 "0 INSULATED SLEEVE - FOOT OF SPRAY BOOTH BOLTS @ 3T -0" MAX SPACING OR PER TABS PROVIDED BY MANUFACTURE PAINT BOOTH ATTACHEMENT TO FLOOR NO SCALE NO SCALE - USE DIMENSIONS NOTES; 1.) BOOTH CONSTRUCTION TO MEET REQUIREMENTS OF FIRE, AIR POLLUTION. AND OSHA CODES.LOCAL CODES WILL REQUIRE FIRE SPRINKLERS IN 800TH. 2.) PANEL PRE -FAB 18 GAUGE GALVANIZED STEEL PRE - PUNCHED FOR NUT AND BOLT CONSTRUCTION. (1)24 WEATHER CAP ( ST GHT IUCT (1)STORM COLLAR (1)ROOF JACK (FLAT) (1)24 -0X48- INSULATED SLEEVE (1)8x12- cam OUT DOOR o 6 MODEL NO. JOB NO. 8546 I--- 7 -6" I.D. 9' -D" O.D. REAR 11U1 (12)207X25 AG28 L1L APPROVED FIBERGLASS EXHAUST FILTERS. 0 (7) APPROVAL DRAWING APVD BY: (DATE APVD: DIST: FINISHING CONSULTANTS CUST: B & K TAYLOR CORP (1)24 DIAMETER EXHAUST FAN. MOTOty 1.5H.P., 208- 230/460V 3PH T.E.F.C. CAPACITY: 6,400 CFM 0 .5" STATIC PRESSURE. (3)VAPOR TIGHT INSIDE ACCESS (T -8) FLUORESCENT Ln.HT FIXTURES 48 4 -TUBE. 120/277J. UNIVERSAL BA4 ST.(TUBES NOT INCLUDED 0 I mo! — L T — zzzzzz3 —1 6' -o" D.O. 1- 12'-0" I.D. 17' -4" O.D. PLAN. VIEW 1 (1)264 - 314 - X24 - STRAIGHT DUCT ((1)2B37CT1 7(36 (1)283'X31}" INLET STRAIGHT �UCT= HOOD W/ BIRD SCREEN —(1)2 7x31 7(18 - STRAI DUCT — 6' -0" D.O. 1-- 12' 0" I.D. 1T -4" O.D. SIDE VIEW DUCT SUPPORT (BY OTHERS) 1363 E. GRAND AVE. POMONA, CA 91766 (909) 623 -694 -3 NOTICE: THIS DRAWING 5 THE PROPERTY OF SPRAY SYSTEMS, SUBMITTED ON THE CONDITION THAT THE PLANS AND DESIGNS THEREIN BE HELD CONFIDENTIAL AND IS SUBJECT TO RETURN ON DEMAND. — (1)8850 HORQONTAL MOUNT DOWN DISCHARGE DIRECT FIRED NATURAL CAS AIR MAKE UP UNIT WITH A 6,400 CFM O S' S.P. 5 H.P. 3 PHASE MOTOR, RAKE CYCLE AND VFD CONTROL PANEL INCLUDED w TITLE: SHEET: (2)■IANOMETER REV. SINGLE LEAF SOLID SLJDING 0) - LOADING DOORS, 6'- O'WIDE 1 I X 7-9 HIGH DOOR OPENING, CO n r WELDED TUBULAR STEEL DOOR FRAMES W/ 18 GAUGE GALVANIZED DOOR PANELS, HEAVY DUTY SAFEEY LATCH. EDGE AND BOTTOM SEALS. CUSTOM CROSS DRAFT PRESSURIZED BOOTH DRAWN BY: CHRIS CHAVEZ 1 OF 1 DESCRIPTION (12)207.25" PAS80G INTAKE FILTERS DATE: 1/23/07 SCALE: BY I --- 7' -6" 1.D. — 9 - 0" O.D. FRONT VIEW DWG NO. DATE 073002 DRAWN TO SCALE BOOTH ELEVATION VIEW SCALE 114" = 1 ° -0 °' C' ) L) co co 1L 0, CC, a(j G7 ELECTRICAL ROOM SIDE D OTHER TENANTS OTHER TENANTS OTHER TENANTS DBL) LAYER 518" GWB (2HR. FIRE WALL) 70' - 0" OTHER TENANTS 1 0) 15' -0" 0 01, r ZO 0, v OTHER TENANTS OTHER TENANTS OTHER TENANTS PLAN VIEW SCALE 118" =1 -0" Mop - z93 RECEVEr DEC 2 7 2007 PERMIT CENT Et 0) CO W 1 - A02 E: 0 c) a as E 0 0)