Loading...
HomeMy WebLinkAboutPermit M05-020 - KELLY GOODWIN HARDWOODSKELLY- GOODWIN HARDWOODS 350 TRECK DR MO5-020 Parcel No.: 0223400045 Address: 350 TRECK DR TUKW Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: 7649 S 180 ST, KENT WA Value of Mechanical: $8,500.00 Type of Fire Protection: N/A doe: IMC- Permit Th City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us KELLY - GOODWIN HARDWOODS 350 TRECK DR, TUKWILA, WA PANKRATZ FOREST INDUSTRIES INC P 0 BOX 58388, TUKWILA WA MARK SMELTZER Contractor: Name: PERFORMANCE HEATING Address: 7649 S 180 ST, KENT WA Contractor License No: PERFOHA15ORT Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 1 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALLING NEW 7.5 TON ROOFTOP GAS PACKAGE A.C. UNIT TO REPLACE EXISTING FAILED UNIT. SAME CAPACITY, DAME LOCATION, NEW UNIT IN EXCESS OF 400 LBS. EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -020 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 251 -0356 Phone: 425 251 -0356 Expiration Date :04/29/2005 Steven Al. Mullet, Mayor Steve Lancaster, Director M05 -020 02/24/2005 08/23/2005 Fees Collected: $258.05 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 02 -24 -2005 Permit Center Authorized Signature: dot: IMC- Permit City oi Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukivila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -020 Issue Date: 02/24/2005 Permit Expires On: 08/23/2005 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfor an w ff rk. I am authorized to sign and obtain this mechanical permit. g Si nature: ' i �(G � Date: 2 —_4.- 5 Print Name: /" k r k Sme(r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M05 -020 Printed: 02 -24 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223400045 Permit Number: M05-020 Address: 350 TRECK DR TUKW Status: ISSUED Suite No: Applied Date: 02/15/2005 Tenant: KELLY - GOODWIN HARDWOODS Issue Date: 02/24/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) doc: Conditions M05 -020 Printed: 02 -24 -2005 � c)4 Cit Y of Tukwila 15: Local U.L. central station supervision is required. (City Ordinance #2051) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 18: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 19: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 * *continued on next page ** M05 -020 Printed: 02 -24 -2005 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 9/,144- A a./-k- M05 -020 of law and ordinances other work or local laws Date: C ' r o'c Printed: 02 -24 -2005 v • W } O: • • N � z Cy 1— 0 :: z i—; W W' M o;. O Ni W W, O, tEt . Z: U co , O , z Site Address: Tenant Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 CONTACT PERSON Company Name: Company Name: PA Mailing Address; Contact Person: E -Mail Address: \applications 'itermit application (7.2004) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 3 50 7rcek prt ve. Mailing Address: PO • boSe. FR 3 88 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record AAA? 4-err Cittly om.4Itctefz-tle. z Page I Building Permit No. Mechanical Permit No. /Q7405 Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 02231'0OO 5 Suite Number: l Floor: i tOOT New Tenant: ❑ Yes lE :.No Property Owners Name: Peinkfct f z ,reT `! '45 /7 , 25 ruCW i (c, lek 98138 City State Zip Name: /Lark cSs/f2er ,j // L Mailing Address: /6 49 9 9 . t180` 1 • /' . w 'so 32, / City / State Zip E-Mail Address: r'KC�per7O `t Fax Number: IQ? ' �lj f Day Telephone: I ' PZ5 ( 66 GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Mailing Address: City State Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record State Zip Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Company Name: 11Cl& Rule I/1eeJ -!t4 tOor> AA � 4`�'�'le- Wk 9810 Mailing Address: /932- '�f ✓"�� ?�1( . , $N.(`�"e S v 9 5'e City State Zip Day Telephone: r ,7 0 6 . 12-8 ' 4Md Fax Number: Ace. • 12S -7 043 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU EvaporatorCooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 1 -1P /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP/I,750,000 BTU HeaURefrig /Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM <10,000 Other Mechanical Equipment t MECHANICAL PERMIT INFORMATION— 206 -431 -3670 MECHANICAL Company Name: Mailing Address: Contact Person: E-Mail Address: CONTR CTOR INFORMATION I, . ^ �ea'- iotrW�c�vl ce A r- 7649 5. (Pei) 54, J iUark' 5' l fgpo- r , cehe - k1 . Contractor Registration Number: ?'O ff7t 5oA Expiration Date: T' a9 ' * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 8 50c) 4).7 /'� Scope of Work (please provide detailed information): /15'u // "I eW � 1. 5 - P7 /ODI/71p y Q S - F acia.9e • wit f o rep! ere ex-154 rl.4 4i t (e uvt j Scorer) Ca fc(e dh , Set e, to c A- nv‘ . Neu Win f eXce55 0-f lex Ms. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to a I permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applint as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTf-i7ED4E2 e Signature: Print Name: Mailing Address: Date Application Accepted: tap plications`permit application (7.2004) (ark S e1 t-ze•-- 7 6 4 9 s . 1 8 0 1 ± 0 4 . Page 4 Co Q E0rtt City State Zip Day Telephone: 1?9 • ' 0 3 6 Fax Number: -2...G 7--S0 Day Telephone: K�02 City Date: / 4.5 .A5( o 3 5 6 W4 - 98032- State Zip "Eo32- Date Application Expires: Staff Initials: S I City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 0223400045 Permit Number: M05-020 U Address: 350 TRECK DR TUKW Status: PENDING co Suite No: Applied Date: 02/15/2005 co w Applicant: KELLY - GOODWIN HARDWOODS Issue Date: 9 W 0 . Receipt No.: R05 -00226 Payment Amount: 258.05 g Q co Initials: SKS Payment Date: 02/15/2005 03:33 PM u i User ID: 1165 Balance: $0.00 ! z W Payee: PERFORMANCE HEATING & AIR CONDITIONING o a l-' w w, TRANSACTION LIST: v; Type Method Description Amount LL O Payment Check 20016 258.05 tjj i V N z ACCOUNT ITEM LIST: Description doc: Receipt MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000/322.100 212.44 000/345.830 45.61 Total: 258.05 9949 02/16 9710 TOTAL 258.05 Printed: 02 -15 -2005 Pr� it wfn Type of Inspe ion: Address: . J «(( k_ Di. Date Date Called: Ala o Special Instructions: - ` V � t � ‘� O(3 Date Wanted: g13 5- m. Requester: `t 1 i 1 J Phone No: (2.06e 551 - Zo i b INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 proved per applicable codes. COMMENTS: Inspelor: .00 REINSPECTION EE REQUIRE ' . Prior to inspection, fee must be id at 6300 Southcente Blvd., Suite 100. Call to sechedule reinspection. elpt No.: 4 INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. Date: 'Date: ffrICE - OW Pr a t: ((/f 1l ��i'i(l/l� of Insp ction: <<// T �� -1( 0 Ad rresss: Date Called: �j U �� �� s Sp�ci�l Instruct ons:Pck Date Wanted: a Requeste Ph ( j 5 3 J - ? /() INSPECTION RECORD /�j Retain a copy with permit /" ` 0 -: 0 � � INSPECTION NO. PERM! CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 VI Approved per applicable codes. 06 431 -3670 Corrections required prior to approval. COMMENTS: i 44/1.4.7 ran J 3 O j .00 REINSPECTION P E REQUIRED. or to inspection, fee must be d at 6300 Southcente Blvd., Suite 1 Call to sechedule reinspection. ipt No.: 'Date: • P oJec : OA I ■ I Ty.e of Inspection: , , I t At I/ 4a..t tc Address: D ( Date Called: / DS. Special Instructio p i ` p? Z ��c O Date Wanted: � a,� m Requester: ` 190) ,-S/ -- aO /O ., INSPECTION RECORD Retain a copy with permit INSPE ' ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 06)431 -3670 COMMENTS: Inspe • r. 1Date - 3 S 8.00 REINSPtCTION Ff REQUIRE D Prior to inspection, fee must be 00 aid at 6300 Southcenter lvd., Suite, . Call to sechedule reinspection. eceipt No.: 'Date: Approved per applicable codes. El Corrections required prior to approval: Ptoje ct:_, i ‘ L4 r J (-1 ei (A bt.ii) 'Typ Inspectipn: \ , £ 1.-1-1 ■ Address 2 ,CD irk 11.4 • Date Calle *s'i.a.i t)c Special Instructions: at.-(90 Date Want edl ( 1o5 a.m. rtm. Requester (42ArL/ Phorr ' / INSPE NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 Ej Approved per applicable codes. INSPECTION RECORD Retain a copy with permit r/4 o 44 • PER 0 / ./ (206)431-3670 Corrections required prior to approval. COMMENTS: or: 4/1Ag, ruL $ 8.00 REINSPEC ION FE REQUIRED. Prior aid at 6300 Southcenter B vd., Suite 100. Ca elpt No.: Date: b inspection, fee must be to sechedute reinspection. 'Date: Pr ect: axAliJin Type f Inspection: A dress: Sn rccc Date C�tfed: gi S cial Instructions: r '0 /j) 2 -! Date Wanted �' (%s a.m. ("1:111-1' Requester: omsg-1_220 /0 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: pt No.: INSPECTION RECORD Retain a copy with permit ,A..JG4.r 'Date: PERM (206)43) -3670 Approved per applicable codes. E1 Corrections required prior to approval. Date: ® Cam r Q� .00 REINSPECTION F REQUIRED. Priof to inspection, fee must be id at 6300 Southcenter : vd., Suite 100. to sechedule reinspection. Pr ct: ■ Type i' Inspection: A dress reCIC I )4 ' Date Called: (J ? X 403 Special Instructions: 6 { c_ € ,," 7 r Date Wanted: „ 1 / Requester: --23 , hone z;: ) X51 x 0/0 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 PERI „ 0 (206)431 -3670 Approved per applicable codes. COMMENTS: t required prior to approval. .00 REINSPECTION FE REQUIRED. Priofto inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. elpt No.: 'Date: Date: City of Tukwila Fire Department rojectName /fie y Address -co f r e 0 r Retain current inspection schedule Needs shift inspection TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Authorized Signature Final Approval Frm Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Occupancy Type: -,% FPO J% / Rev. 5/2/03 Permit No. MOT 03 - F - o L ice Date Suite # S)-3 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 sliderule tnginrrring wor*r, Nf Project Engineer: Contact: Design Criteria: Loads: n Mechanical Equipment for Kelly- Goodwin Hardwoods 350 Treck Drive Tukwila, Washington 98188 2005.3002.00 Andrew L. Herrick, P.E. Sliderule Engineering Worka 1932 First Avenue Suite 809 Seattle, Washington 98101 (206) 728 -4844 Mark Smeltzer Performance Heating and Air Conditioning 7649 South 180 Street Kent, Washington 98032 (425) 251 -0356 2003 International Building Code Dead Load: 10 psf Live Load: 25 psf (snow) TRANE YSC090A3 *H: 866 pound unit (max) Seismic D -2, Ip = 1.0 Rp = 2.5 ap = 1.0 COpr Permit No. RE E COMPL� LA CODE FEB Aroripm 2 3 'l005 at t OWING DIN1§1.01\1 Lateral: New equipment does not have significant impact to the building's lateral capacity to resist wind or seismic forces. Use: All metal members and connectors shall be galvanized. All screws, nails, and /or bolts shall be galvanized. Install HVAC and ducts per manufacturer's specification. O' _ 4x and 6x Lumber HF #2 KD Fb =1000 psi (min), E= 1,600,000 psi (min). Trustoist LVL members Fv =285 psi (min), Fb =2,600 psi (min), E= 1,900,000 psi (min).��f� a 20 05 mifire Calculations are for TRANE YSC090A3 *H no other portion of the Tenant Improvement or Structure. 1932 first avenue, suite 809 seattle, washington 98101 -2498 t = 206 + 728 + 4844 j = 206 + 728 + 7643 w' = sliderule.biz • 11-"A1-1 E ° A3 4 41-Fs. y 2 S G1 S Cac l) `7 %'19 - r 4-o slC:c (4X t-t- +) y ;" t„-- 1-- G71�6 Z, 4 - 1 11- o (4) W4 1 r sours -tv �t 44.= I' "2 Z51 • f - M c / ale � - -•t� -� -rule engineering works, !!r tT ,,II Z- D k T 473 ePuert— "7tZk- r1 I . -4 11 `tic (4 l•ti 7 347 o I Z13 1932 first avenue, suite 809 r = 206 + 728 + 4844 f() = 206 + 728 + 7643 w = sliderule.biz V__ - 17'' - �1 ✓- ACAr � 611. L21 �'LS `I Yls - vwr r czSG 6A11..,_ vv"w""v \Den.4,1 i-ce( )( ( .vtt i 20 (Z- 4 e- 5 ‘'° 1‘ 4 < e ) seattle, washington 98101 -2498 what: \" when: 2(» !Pc, 2 o lL RECEIVED --- .CITY OF TUKWILA FHB 1 5 2005 PERMIT CENTER page: who: t 8 •o 1I 4 z W -J 0 0 y LU W O u-? u) Z I- O z I- 0 ON 0H W H 0 17-," H z // -tDZGE 4 4y_tz.- E4v.6, e 4x1 @ 1 ems► w10 kg e b/ 614 -rel-P tM f tt- sLlt v � I1 11 loy�4 - 7'05 r i � 1 v l(41 engineering works, lie 1932 first avenue, suite 809 seattle, washington 98101-2498 r = 206 + 728 + 4844 J 206 + 728 + 7643 r,1= sliderule.biz 6( at: j Z ,,..7 d D \► CO t ttA4'v,. • RECp C11y OF ruovu FEB 1 5 2005 PEAMr CENT what: - Cl ' who: A when: �i L page: 0 • AVErrhaeuter Rusin• TJ - Beam(TM) 0.10 Serial Number: 7003008031 User: 2 2/15/2005 11:26:51 AM Page 1 Engine Version: 1.10.3 Member Slope: St12 Roof Slope0M2 AN dimensions are horizontal. LOADS: Analysis Is for a Drop Beam Member. Tributary Load Width: 8' Primary Load Group - Roof (psf): 20.0 Live at 125 % duration, 10.0 Dead Vertical Loads: Type Class Live Dead Location Application Comment Point(Ibs) Roof(1.25) 0 1 13' - SUPPORTS: Input Bearing Width Length 1 Stud wall 3.50" 3.50" 2 Stud wall 3.50" 3.50" DESIGN CONTROLS: Maximum -2469 12140 Shear (lbs) Moment (Ft -Lbs) Live Load Defl (in) Total Load Defl (in) PROJECT INFORMATION: Kelly- Goodwin Hardwoods G Vertical Reactions (Ibs) Live/Dead/Uplift/Total 1600 /911/0/2511 1600/911/0/2511 Design Control Control -2160 3671 Passed (59 %) 12140 10668 Failed (114 %) 0.467 0.656 Passed (L/505) 0.733 0.983 Passed (U322) - Deflection Criteria: STANDARD(LL:U360,TL:U240). - Bracing(Lu): All compression edges (top and bottom) must be braced at 0 o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing Is required to achieve member stability. -The allowable shear stress (Fv) has not been increased due to the potential of splits, checks and shakes. See NDS for applicability of increase. - Analysis based on vertical loads only and assumes structural supports as noted in the input. Axial loads are not considered in this analysis. ADDITIONAL NOTES: - IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). TJ warrants the sizing of its products by this software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by a TJ Associate. -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. -Solid sawn lumber analysis Is in accordance with 1997 NDS methodology and is solely presented for comparison purposes. Program limitations and assumptions about this analysis are available through the software's On -line Help. Trus Joist does not warrant the analysis nor the performance of solid sawn lumber materials. - Allowable Stress Design methodology was used for Building Code IBC analyzing the solid sawn lumber material listed above. Copyright 0 2003 by Trus Joist, a Weyerhaeuser Business existing 4x14 wood purlin 3 1/2" x 13 1/4" 1.7E Solid Sawn Douglas Fir #1 MEMBER IS INSUFFICIENT DUE TO LOAD Detail Other By Others None By Others None Location Rt. end Span 1 under Roof loading MID Span 1 under Roof loading MID Span 1 under Roof loading MID Span 1 under Roof loading 20' Product Diagram is Conceptual. OPERATOR INFORMATION: El C CE ruinviLA FEB 1 5 2005 P ERM1rc EN . EA Z cc 1 U 0 to W = LL W 0 : N D. CJ. I- 0 • W p .0 . ;0 N W W: O W Z H =' 0 H: Z Wei A NYkyerhaeuser Business TJ- Beam(TM) 6.10 Serial Number: 7003009031 User: 2 2/15/2005 11:27:46 AM Page 1 Engine Version: 1.10.3 Member Slope:1M2 Roof Slope0M2 AN dimensions are horizontal. LOADS: Analysis is for a Drop Beam Member. Tributary Load Width: 8' Primary Load Group - Roof (psf): 20.0 Live at 125 % duration, 10.0 Dead Vertical Loads: Type Class Live Dead Location Application Comment Point(Ibs) Roof(1.25) 0 143 13' - SUPPORTS: Input Width 1 Stud wall 3.50" 2 Stud wall 3.50" Bearing Length 3.50" 3.50" DESIGN CONTROLS: Maximum -2562 12630 Shear (Ibs) Moment (Ft -Lbs) Live Load Defl (in) Total Load Defl (in) 0 Copyright ° 2003 by True Joist, a Weyerhaeuser Business existing 4x14 wood purlin w/ corner 'A' HVAC 3 1/2" x 13 1/4" 1.7E Solid Sawn Douglas Fir #1 MEMBER IS INSUFFICIENT DUE TO LOAD I I 2 1 20' 1 Product Diagram is Conceptual. Vertical Reactions (Ibs) Detail Other Live/Dead/Uplift/Total 1600 /960 / 0 /2560 1600 /1004/0/2604 Design Control -2253 3671 12630 10668 0.467 0.656 0.762 0.983 Control Passed (61 %) Failed (118 %) Passed (L/505) Passed (U310) By Others None By Others None 4 Location Rt. end Span 1 under Roof loading MID Span 1 under Roof loading MID Span 1 under Roof loading MID Span 1 under Roof loading - Deflection Criteria: STANDARD(LL:U360,TL:L/240). - Bracing(Lu): All compression edges (top and bottom) must be braced at 0 o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. -The allowable shear stress (Fv) has not been increased due to the potential of splits, checks and shakes. See NDS for applicability of increase. - Analysis based on vertical loads only and assumes structural supports as noted in the input. Axial loads are not considered in this analysis. ADDITIONAL NOTES: - IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). TJ warrants the sizing of its products by this software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by a TJ Associate. -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. -Solid sawn lumber analysis is in accordance with 1997 NDS methodology and is solely presented for comparison purposes. Program limitations and assumptions about this analysis are available through the software's On -line Help. Trus Joist does not warrant the analysis nor the performance of solid sawn lumber materials. - Allowable Stress Design methodology was used for Building Code IBC analyzing the solid sawn lumber material listed above. PROJECT INFORMATION: OPERATOR INFORMATION: Kelly- Goodwin Hardwoods op ru, FEB 1 5 2005 PERMIr CENTER TRANE YSC090A3 *H 2003 International Building Code (Section 1621.1) Mechanical Systems Section 9.6.1.3 of ASCE 7 -02 Site Class = D S = 1.25 S = 0.40 Rp = 2.5 a = 1.0 z /h= 1.0 Ip = 1.00 base length = curb height = equip height = Fp = 0.40 Wp W p = 866 Fp = 346.4 lbs 53 in 8 in 40 in M of = 808.27 ft-lbs figure 1615 (1) figure 1615 (2) ASCE 7 -02 table 9.6.3.2 ASCE 7 -02 table 9.6.3.2 equip ht / bldg ht hazardous matl Ip =1.5 M r = 1721.2 ft-lbs reduce DL by 0.9 Uplift = no uplift no W/D caic req'd F = F = SMS = SM1 = SDS = SD1 = Seismic Forces (ASCE 7 -02 9.6.1.3) Fp = Fp max = 1.0 1.6 1.25 0.64 0.83 0.43 table 1615.1.2(1) table 1615.1.2(2) equation 16 -38 equation 16 -39 equation 16 -40 equation 16 -41 0.40 equation 9.6.1.3 -1 governs 1.33 equation 9.6.1.3 -2 Fp min = 0.25 equation 9.6.1.3 -3 Fp = 0.40 Wp equipment curb base length equip height A curb height crr% gcit/V D PEE' 1 5 2005 P ERMIT carrell Feb op 05 12:28p • Jan 10 03 10:18a . ..... •• •■•••,.. • ••••• • 1•• •• ,•:*••• • . ••••• . • , , ...r.,,•••••)•••••:,•••••• ••• • • • • • , • • • 4 • •••• • ,t• • •• . • ••. •1 NQI114;••• • 4' • ." ..• r* " • • - • _.1. .‹ . . ••• I •• ' : ' ,..„ • • • ' t, 1 • ■ . r • ' ..." • — ! • "'+' ; •• ';i•:!: —10 I. • 1.4 . f .4. 1 ;0 0 .• • 0.••••• ••• '1 44:" .• —4 I • • 1. • • • . ••: ; . 4L-t;EFEZ 41-Igelt§r,. 1; Hem ,Lti 7, 1 17 1 7 a Ft - 114 4sW'r f or manc 4 I?t i n 14P q 1 Pe. . ormende Heat Lnc • 1' (425) 251-0280 "- (42: 251-0280 .$ • •. 1 3 '"'• • r ••• .. • P 5 r • 2 • • •-r mow* ofilt-mnol 1,.i •• . 1 • .• • ••.. . ••.,‘ .•••• • • • f. • " "-, f • " I ••••• • • 14 ‘11••• - - .1 :4. .7 .. • N. , .• • l•-• • 11 '1; . ... • • .•.. . n .• • .....•. : -: .... ' . ' •'.. ."'•••.... ' ;',.r. - --4.-■•••••••• ll'''.1::',":..1"`i:;71.-4N•177"5"-r '". • " ' :•).. , '...; -4. 1,,, . ,.. ., ..., - ... : •; ' l'%:, ' • '7" .... 1.; „ • ..,.,.::.: : 1;.4t.:::, .....' "•,, 1. . --.,........ i- r . ...i...' 4 0 : ' ,, .. ........,,.. ••• • .,-. r •••••‘ .; '''''. . ''''' I ..... ...'.,! ..:.,...K., ,..,..:4.•...„.• .• . '... " . .....:.• ....,,.. t•-. . . .. . sfr ,. .....,.. ..e .... •,. ... ._ ... T... ." • • ' ; • • . • .. • • .••• ••■ ;••" . • • • • • • * **** < ; • • • • • • • :**'• • • G.L1 14-1A4- aHir e EA t211-L 04 OPro FEB 1 5 2005 P ERmirc eivrei • • < Z tt 2 • 0 co 0 U) UJ L _ L J I co u. uj 0 g u. < Z i-0 Z ui 2 • 0 0 D. H . tu u , • 0 u. z 0 Feb G8 05 12:20p Performance Heating • Jan 10 03 10:19a 74 • Ail dimensions are in inches/millimeters. 616n Slandard and Nth Mr.'fein y 714 Ton Standard Efficiency JAN -10-2003 10;E18 1N, "'TAM= Pt ormance Heating Dimensicunal Data ALTERNATE CQNOGN5AT! DRNN CONNECTION W4. 14 NPT DLL NOIE •�\ \� 761 MIA f is ., 1E16 t201 • 714 Ton High Etlbcienry 8f4 and 10Ton Standard end High Efficiency MI Evan: MAMA SECTIDN ACCe0S eon WV NPT OAS CONNECTION 100 nth IVO 460; 314 NPT GAS CONNECTION (I O 14 41 , , 14 41 , , Coo NM 230 nbo5 1 N W K /EM1R!! COraENNTE 1y11N p cuNSCTIL11 2N • II NPT MILMIA �. • 113 14 NAT O4t COMRC11MN (5t mah 1E5 n•/VI •M T OAS CONNtr111W (133 314 20, ryh IM �••N 1 � 1 I' It we 701 5 • • 5251 Y �.•� . / 425 251 E280 CONT SO. AND COMPRESSOR ACC3 ;6 11EL Cc 11Th: L AA110 COMP/1E06os 42 :34 R PAWL (425) 251 -0280 (4. 251 -0280 [ jl�ftlJ1+ V �Y•e 1: ' � 11Y �t 1. ,--TOP PANEL M14 43 1341*4 111134143731 7 -To• *NIL ■ 95% CONDENSED FAN 1100 p•4 CONDENSER COIL UNIT CONTROL WIRE 7A• OINK OK HOLE SERVICE O4IJ3M PORT ACCESS 1 15!" 435341} DA HOLE win. POWER WIRE I NV (75MM b1A. HOLE ---- CONDENSER COIL `IJIn CL131N1r_ WIRE >'.' (Mho OA. HD(1 sum= 033013 PORTAOCEUE 1 aAl• (xMNR OIA.I Iq,E 31K71 POWER WINE 1 UV MAIM DIA. HOLE p.2 4E) OP r CIO COND1NK14 KAN / Eg 1 5 2045 kA PE RM /rc 41 A• cR 1110 NM Fb 08 05 12:25p ..lan 10 03 1020a 78 • MAME- WNETPIle 1121.11F NOCIO . . 1111101 640 Tons — foonorntrer and Demme& Heller Damper Hoods 6.10kins — Swing Diameter for Hinged Dons/ (*ion Performance Heatinc Pe.,;ormance Heatinc Data .Dimensional f)e .10•141 • I: ALs1;oe.:..c4selixlgas. cM MOM II Tf.,10 -1M -OMM 4M!MP c.DpIn (425) 251-02E10 (42... 251-02130 &Wrong — Power Exhaust 6-10Tons — Height of Gas Pipe toquired from Inside Ilan of Unit to Gas Shut off storm* (Faeltvy Provided) P.OS p.3 p.5 onf -Pro FEB 1 5 2005 P ENor ceNTE.R (=eb 00 05 12:28p Performance Heating in 10 03 10:20a p. .ormance Heating • Itbt.VW1 -- Maximum Unit And Camer Weights (LbatAnd Cur 191 Of Gravity Dimensions I ,J Corner Weight. (14,11 3 Unit Toni Model No. YSCO36A YWCO3M YSC048A YHC049A YSC060A YHC090A YSt172A3•H 4 5 B'h HT PRC006•EN •H YHC092A3'H YSC102A3• H YHC102A3•W 10 YSC120A3•H YHC120A3'H *NE 1. Caner tr.lgtlte tae Owen for riennWon only. 2. Weights •r aoorvximea. Ogri: a7-19 JAN - 16 10:08 534 551 558 MI 574 520 822 1010 988 1044 1074 1147 Weighi,El I. Maximum Weights ILbsi' ShIpp1111L Net A 151 158 758 196 4ao 497 505 539 522 574 9 0 *vI OF 044WTY WiDTN 923 8% 9157 967 1060 A :136 io :25 :42 C101719 OF amity — 425 251 E280 B C 124 86 128 101 lot 114 105 119 132 141 130 133 130 140 193 sa 208 148 243 243 252 255 277 1425) 251 -0200 (4E 251 -028 185 165 175 183 197 'Die ■2 — F4rooeytihesea#ad Options Net Mighty absti Attellsory 00411101 Et ortomi r & rontatric R.lid 7 voo lr Pt were() Exhaust — M:torilad Outeida Air Damper 20 *null Wilda Air DemP.r 16 Ai?, Curb 70 U uraiaad Motor • 5 811 Drive Motor 31 anal(' 0etocoot. Return 7 Sn 1oks Detector, Supply 5 roI Guards 12 Wk ued Doom 10 l'o'rerad Convenience Outlet 38 "stal9h the Base Electrical 8 r hi move the Biler Gee 5 an 1 Mounted Cirrult Breaks, 5 Inl Mounted Weoorinsct 5 '104ar Control 0 011:3. t.yh'Ghla lot Doom nq tto it1 ure so' Oa. 141 wolph1►htMt104 itldMl ID unit w, hl (Men (rdeiwp I. uy•hetated eccesPIXlei. 210 t04 220 213 246 " Net WchsI It 3.5Tone 26 6.10 Tone 36 10 m 30 26 115 8 7 5 20 13 38 13 5 5 5 8 p.4 p. 6 [tinter of Gravity 11n4 0 Lori th Width 109 110 108 126 114 136 4n. to 183 38 22 32 19 32 19 33 18 32 20 32 18 32 20 39 21 38 2Z 40 21 40 22 40 21 40 22 79 P.05 File: M05 -0020 •35rnm Drawing.. #1 07 -05 -2005 MARK SMELTZER 7649 S 180 ST KENT WA 98032 RE: Permit No. M05 -020 350 TRECK DR TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, ( inentee, Brenda Holt, Permit Coordinator xc: Permit File No. M05 -020 Bob Benedicto, Building Official City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/23/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 4 ACTIVITY NUMBER: M05 -020 DATE: 02 -15 -05 PROJECT NAME: KELLY - GOODWIN HARDWOODS SITE ADDRESS: 350 TRECK DRIVE X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEP RTM NTS: Buil • i, Divi on 2 -O Public Works ❑ Documents /routing slip,doc 2.28.02 PERMIT MOD CL) PLAN REVIEW /ROUTING SLIP Pg•.i -iMR „ + (I2- /11,0b Fire Prevention Structural ❑ Planning Division Permit Coordinator �C DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -17 -05 Complete [d Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURSTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03 -17 -05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: p DATE: C Sill 35110N SIHI NVH,1,,NY310 5531 SI 3VW SIHI NI 1N3N111000. 3H1 41 :33110a ' F625-052-000 (8/971 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL . _ _ . CCO1 PERFOHA15ORT EFFECTIVE DATE PERFORMANCE HEATING 7649 S 180TH KENT WA 98032 EXP. DATE 04/29/2005 12/30/1985 & A/C INC REVISIONS - I ON Kelly - Goodwin Hardwoods DATE: 10 FEB 05 DRAWN: MS ENGR: MS APPVD: JOB NUMBER: 5054P M i SHEET 1 OF 1 NEW DUCT W/ 2" LINER ---t INEGT NEW TO EXISTING TING i SUPPLY DROP THR11 R O TING > RETURN DROP TIRU R •••••••••••.+•••••••••=mem• • 4- I I • 1 • REMOVE EXISTING FAILED UNIT t REPLACE hl/ NEW R1111 -I. ALL RTU-I ON NEW 4X6 SLEEPER5.111A ARE PERP. TO EX TII$ SLELI'ERS ATTACHED Si11R74L FOR EXACT LOCATION). UNIT TO EXISTING SUPPLY DUCTWORK AS SHOWN. • r;OVE NOTESti I) SEAL DUCTS PER W.SE.G. SECTION 1414.1. 2) INSTALL DUCT SMOKE DETECTOR TO COMPLY W/ I.M.G. SECTION 606. 3) INSULATE ALL SUPPLY t RETURN DUCTS TO COMPLY W/ W.SE.G. TABLE 14 -5. 4) PROVIDE ECONOMIZER PER W.S.E.C. SECTION 1413 4 1433. ■ ■ ■ i ■ • • • • • l t • • • • -4- T VI/ 2" LITER • • • PARTIAL HVAC ROOF PLAN SCALE. 1/8 "-1-0" 541:E OF h (u REMOVE (I) EXISTING FAILED ROOFTOP GAS - PACKAGE MR GOVITIOPMN6 (NT i REPLACE MTh RN MIT OF SAME CAPACITY IN SAME LOCATION. MODIFY EXISTING ROOFTOP DUCTWORK TO MATCH SUPPLY 4 RETURN MEW'S OF lel (NT. GOIt CT ITEM UNIT TO EXISTING NATURAL GAS, LIP VOLTAGE, 4 LOW VOLTAGE UTILITIES. ■■■■■ ■ 1 1 1 1 1 1 1 1 1 1 ■ ■■■■■ ■ 1200E 411I• � • • • • • h :: • • • • -- 111111111111 ■ Ell= ■ MN= ■ 11111111111 ■mow■ MOM ■ • • 1 • • • N • • • IFIL,! OO/1f Pant* No. /141)7 0 20 Plan review approval Is subject to effors and omissions. 1 uh.,ioanon of any adopted code or ordinance. Receipt cif approved Field Copy and mwar adcnoveladgmh SEPARATE Odee1RT REQUIRED FOR: Mechanical d Electrical i Plumbing d Gas PiOng Qty Of Tukwila BUILDING DIVISION CIS of Wats BUILDING DIVISION No changes doll be sunk te the scope of work without peter approval of • Tukwila iOevhior�wlM � s �y � M obzo arid may include eddltiormi plan review •INCLUDES ECONOMIZER i BAROWTRIG RELIEF • SCALE. 1/32"=1 SOUTH f� SITE PLAN NOMNW'L MOOR FM HVAG EQUIPMENT SCHEDULE TA6 MANUFACTURER DESCRIPTIOM MODEL NO. TONS CFM ` 5P , FF WEIGHT MR1 LOCATION REMARKS RTU-I T12ANE ROOFTOP GAS PACKAGE AIR COIVITIONER YSC0g0A4RIA0OI6 1.5 3000 0.5" • 2.0 CAPACITY - BMI E1,fGTRlGA1 _ 501A0 HEATING COOLING �'�.� /1Fl1E HST VOLT5j . MO�C�P ci1,200 c10,000 1031- 8196 460 PFNbE I l4G l1 30 22b PINASE MGA 3• 22b 35D ao 800 ROOFTOP hY ECONOMIZER 4 SMOKE DETECTOR VICINITY MAP NO SCALE TREGK DRIVE NOTE: gINS CW41Y PARCEL N0,s 0223400045 LeghtLirlgeffiglis ANDOVER INDUSTRIAL PARK •5 POR BE& NE COR TH HLY AL6 CURVE TOR6T RAD 410.28 FT CENTER BEARING N 04 - 42 - 41 E G/A 01 - 42 - 08 015T 12.11 FT TH N 84 -25-51 W Ig8.11 FT TH AL6 CURVE TO LFT RAD 410.28 FT G/A 11-03-01 0I5T lg.I3 FT. TO TPOB TH C.ON'T6 AL6 CURVE TO LFT G/A 5q -31 -I1 DIST 426.'3 FT TH 588 -56-41 E 76.41 FT TH 5 45- 31--41 E 1032 FT TH 5 88 -16 -I1 FT TH N 0I -41 -28 E 21232 FT TO TPOB LE55 UP RR OPER RM 1 � �ENE'D TUKWA.A FEB 1 5 an PERMIT CENTER M 1!!R! �J1i� II!!C1 . C.AT101i I aurae, A1! WIZ QTY cP w�ce IeA T1wi I A� co- �o�w *, Mc. A�+�� T� r � v Bri r+oie w x� i ZIPIOO111AI,. At OP AMO AND TI x "OM��M1L TAO 1��FI n!!! R/V r fr . JWr OIS•11*1AT1A1 OP SX11 rMT st at P RfOND 116110WP TO AN ADVn1aNIL r�ARATIAI OP s�cN w► II N NIr U C flvK. ae DMM�MJ �1~T1w 1*Og1 = TlON. K' 0IM1UI• A1V IPICIPICATION1 411111 _ __••∎• r.: I 0 00.0 0 ." w.. 0011M. - ,ow. • •Norir.s.Mr+•rw... w., r.+�.w�.ti.'l.�w.ew «K ♦ 4 : . _ .. . .. . • - .:.: w w • r File: M05 -0020 35mm Drawing #1 I 6-3/4 618. I I ■ SCALE: 1/4' =1-0' 10- 1/4X63/4 61. TYP. 5►4DOLE, TYP. I ■ 4- - - ■■�■ 6- 3/4X26 -V2 618. I I I ■ PARTIAL HVAC ROOF PLAN I I I AB :__I I I I I I - 1 - I ISM IMO I I I I I I I I I I I I ■ Mlle IMO - — L -- I-- - - II 1 1'II I I f 1 I 11-j Inch 1 /16 IIII 3) �Ii . �II _ ( LI II - iI i1i.i1i I ill iji I ili ili ill I I lil li I II 4I 5) I 6 I d II LII I II I I II IL L II . III I I IIII LLII I IILII�III��III LII I I II I 9 E z w� III.. I I II I I 111 I IIIII 11 11 1 11111111 11 1111 IIIIhII 2X4 • 2 O.G. TYP. 3 -V2XI3 PURIM 16'-O' OA TYP. 6' THICK TILT-JP CONCRETE HALL. zzov 0 1Rihr,t \\--/ w/s,