Loading...
HomeMy WebLinkAboutPermit M05-021 - JUNCTION WEST - LOT 2JUNCTION WEST- LOT #2 14906 MACADAM RD S M05 -021 Value of Mechanical: $5,200.00 Type of Fire Protection: N/A Owner: Name: TRYON CONCEPTS LLC Address: PO BOX 46, RENTON WA doc: IMC- Permit City of Tukwila Parcel No.: 7661600207 Address: 14906 MACADAM RD S TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Tenant: Name: JUNCTION WEST - LOT 2 Address: 14906 MACADAM RD S, TUKWILA WA Contact Person: Name: DON TRYON Address: 8210 154 AV SE, NEWCASTLE WA Contractor: Name: TRYON CONCEPTS LLC Address: PO BOX 146, RENTON, WA Contractor License No: TRYONCL013DH DESCRIPTION OF WORK: INSTALLING A GAS FORCED AIR HEATING SYSTEM AND A GAS HOT WATER HEATER Furnace: <100K BTU 1 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 4 Ventilation System 0 Hood and Duct 1 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -021 Permit Number: Issue Date: Permit Expires On: Phone: 206 355 -8909 Phone: 206 355 -8909 Phone: 425 - 255 -6518 Expiration Date:02 /11/2007 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -021 06/07/2005 12/04/2005 Fees Collected: $223.48 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 1 Wood /Gas Stove 0 Water Heater 1 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 06 -07 -2005 Permit Center Authorized Signature: Signature: doc: IMC- Permit City 6 Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us M05 -021 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -021 Issue Date: 06/07/2005 Permit Expires On: 12/04/2005 Date: 4 - 7-0.x' I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: — US Print Name: . 0c9 rleOrl This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 06 -07 -2005 City of Tukwila Parcel No.: 7661600207 Address: 14906 MACADAM RD S TUKW Suite No: Tenant: ]UNCTION WEST - LOT 2 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Number: M05 -021 Status: ISSUED Applied Date: 02/16/2005 Issue Date: 06/07/2005 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 7: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 8: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 9: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 11: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M05 -021 Printed: 06 -07 -2005 - Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. l o (rt t r, a v of law and ordinances other work or local laws Date: (, -- – 7 — c? M05 -021 Printed: 06 -07 -2005 U U O; to 0 , CO ILL N w, w u _ Da. w ? H' r L 0 ' U co ; •'0 H` w W.. o Zi Lij 0: • z Site Address: 'Tenant Name: Property Owners Name: - 17i ( r)64 at) cepi L t C. toe) Col< (46 Oef.t City Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 /4146 M4 124 5' Name: 77 O Mailing Address: 8Ll0 (54 4'&I& E-Mail Address: Company Name: ---. 77 — ?9oAi C 4- 4 C. Mailing Address: [340)e- ( Contact Person: A.) E-Mail Address: AR iI ptant,muit, be:viet stallipict btArchitett t +:11'• ■••• • i• . • r.• • ',I..; .; .". XNQINEER:.OVRECORDitilpheiti must liewee Engineer of Record Contact Person: CA pr 5 Cev't * E-Mail Address: UpplicationApennit application (1-2003) 1/2003 ... LA C c U Zoe I ry,Alt.55/C C Page I Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: (600 e Suite Number: City Day Telephone: Fax Number: New Tenant: .... Yes ..No te,4 State Floor: City State Fax Number: 6145 z53,az fd 57 Zip „ ERS Day Telephone: e-06 355 45767 icieef)("4/ .ge Pee 5'9 GE RAL, ONT CTORI ORMATI 4.)4 P 57 State Zip eO6 355 eP 4 et5 e55 Y6 Contractor Registration Number: 12 oat) C (. (3 . 0 (-4 Expiration Date: 2- ft - 0 7 An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** Company Name: Mailing Address: Po .tloy (46 Pct.-lac& (tap prft4S7 City State Zip Contact Person: j'e. tvz Pa 5 eo Day Telephone: 106 I ? 7 355— E-Mail Address: Fax Number: 1Z5 Z 2 r 7Z Company Name: 5%7 U sac (calr.5 Mailing Address: ZZ (0 1-1(24)'7'?' Aloe- cue* 442/ everetI wet FiZo/ City State Zip Day Telephone: 5 g..7? cZY3 Fax Number: <IZ 5' ZSZ 0?(C .. ....... .0.4.141.11,4•4akke• Unit Type:::. :. . .. Qty .: Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >I00K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /I,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent I Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind MECHANICAL CONTRACTOR INFORMATION Company Name: P P 4 S Mailing Address: (2-o 22 qg 4t,. Ave- N K(glaA 0 7 City Contact Person: --le FF 3f�K. E -Mail Address: Contractor Registration Number: a pS C.-415541e Expiration Date: 6 3 d * *An original or notarized copy of current Washington tate Contractor L icense must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): S SZ Scope of Work (please provide detailed information): l S U . 4 qQ 5 reel /4 r /167 -7 'if 5 p54-eok au. a fa q &o4er (het -lie-- Use: Residential: New .. Commercial: New .. Fuel Type: Electric ❑ Print Name: moo. (R Q O 0-) Signature: Mailing Address: A t ego (S4 Ave s : - \applicationatpermit application (1.2003) 1/2007 ..❑ Replacement .... ❑ Replacement .... ❑ Indicate type of mechanical work being installed and the quantity below: Page 4 COQ Wt. 3 � Stale Zip Day Telephone: Wes Q2S Off- Fax Number: Gas ....VI Other: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Date: L' ( S" 0 Day Telephone: Z06 355 crib? N eedcas-( <e tJc gab 59 City State Zip Date Application Accepted: 0,—/4 -z' Date Application Expires: -�� - Staff Initials: ZAS i ii�iwAGiFs'```M1jrk?t Suite+ iaS- .k;���.•r.,:`'uf;:SzL:'.:; ':�:d • Receipt No.: Initials: User ID: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Z W Parcel No.: 7661600207 Permit Number: M05 -021 a .. Address: 14906 MACADAM RD S TUKW Status: APPROVED N p '. Suite No: Applied Date: 02/16/2005 co W Applicant: JUNCTION WEST - LOT 2 Issue Date: ,. W u_ W 0 . Payment Amount: 184.78 u_ ?' Payment Date: 06/07/2005 11:13 AM 111,7 Balance: $0.00 t z l I- 0 ,, W ~ 2 Ill D 0 '. LI cat WW V Amount I—I W 0 '. R05 -00835 SKS 1165 Payee: TRYON CONCEPTS LLC TRANSACTION LIST: Type Method Description Payment Check 3668 MECHANICAL - RES RECEIPT Account Code Current Pmts 000/322.100 184.78 Total: 184.78 3906 06 /08 fra6 TOTAL 10503 =:16 Printed: 06 -07 -2005 • 184.78 f U co Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: JUNCTION - LOT #2 R05 -00231 SKS 1165 TRANSACTION LIST: Type Method doc: Receipt Payment Check ACCOUNT ITEM LIST: Description PLAN CHECK - RES 1427 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 7661600210 14906 MACADAM RD S TUKW TRYON CONSTRUCTION LLC Description RECEIPT Account Code 000/345.830 Permit Number: Status: Applied Date: Issue Date: M05 -021 PENDING 02/16/2005 Payment Amount: 38.70 Payment Date: 02/16/2005 02:06 PM Balance: $184.78 Amount 38.70 Current Pmts 38.70 Total: 38.70 0006 02/17 9716 TOTAL 1623.21 Printed: 02 -16 -2005 Prota: L CY2 /N / dN tW s7 f Type of Inspec Toni- ' Address: /4 /7 (' 4 /3//4-7 Date Called: Special Instructions: Date Wanted; _ � :.m. Requester: Phone No: pproved per applicable codes. INSPECTION RECORD Retain a copy with permit PECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 T_ N PE ..(206)431 -3670 El Corrections required prior to approval. COMMENTS: ( ii/f 1 58.00 REINSPECTI0) FEE REQUIREDtt to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: 'Date: Proj�: Type of Ins ection: ----- Address: /77 fI el 7,z 9 h "`7 Date Cal Special Instructions: Date Wanted: a.m. Requester: Phone No: 5 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 01:=867 Approved per applicable codes. 0Corrections required prior to approval. COMMENTS: $58.00 REINSPECTIO FEE REQUIRED. rior to inspection, fee must be paid at 6300 South nter Blvd., Suite 100. Call to sechedule reinspection. Proj c�rvc��nJ o ectio • i- Type /) 1 < insp �� S Address: Date Called: Special Instructions: Date Wanted: 6. am: Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPFCTION NO. CITY OF TUKWILA BUILDING DIVISION VI Approved per applicable codes. PERMI 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 O Corrections required prior to approval. COMMENTS: Date /4€41."4, l .44 .44-," .4 ♦ c..... $ 0 REINSPECTION F E REQUIRED. Priol inspectiol(, fee must be p at 6300 Southcente Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: W UO; � � w U. W Q O LL -I U! � wut O' D o • 'O N W u. ai O Pro's: 411 Lir 7/A/07 Type of spection: ,__,_ �i'� _.LA/ Ad-dress: Date Called: Special Instructions: Date Wanted: - ---© / t.... .m a. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER NO. �f (206)431 -36 roved per applicable codes. 0Corrections required prior to approval. COMMENTS: 8.00 REINSPECTION EE REQUIRED. P • to inspection, fee must be paid at 6300 Southcent r Blvd., Suite 1 '. Call to sechedule reinspection. I Recelpt No.: 'Date: INSPECTION RECORD Retain a copy with permit intaire INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1206)431/367 PERMIT NO. 1 4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: 'Date: oject: Type of n �.:. • 1 A dr s . t b t'( (� � � KAli Date Calle . : // t/ D5' (3� Special Instructions: ' d Date Wante cc---,�, I C UO J D/ a. p.m. Requester: -- Pho ° - •- 7 .5- 29 09 INSPECTION RECORD Retain a copy with permit intaire INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1206)431/367 PERMIT NO. 1 4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: 'Date: /1/toS-oo, INSPECTION RECORD Retain a copy with permit INSPECT! N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Type f Inspection: Dare ailed: ProjeFt: Z.01 ..2. -CA / Address: c/ / ,/f-let Special Instructions: /dee s a.m. Date Wanted: /4 Requester: ) 1 bAPproved per_applicable c /771 Phone No: / C7 ' - ? . 5 ( rC ) , Corrections required prior to approval. COMMENTS: M /V(€/,,,- o, 742 /1/ 6 /e7 5-C 7 el-1 ed -(// ,&/ C 4 3 / ;42 5/74 tc f 'Inspector" "lines_I 'Date:, 6 2 7 5 — ri $58.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be " --1 paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: 03 -03 -2006 DON TRYON 8210 154 AV SE NEWCASTLE WA 98059 RE: Permit No. M05 -021 14906 MACADAM RD S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division: Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days.from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one or more extension of time for additiona perios not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04/12/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ifer rshall, Permit Technician A044 xc: Permit File No. M05 -021 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670 • Fax: 206-431-3665 ACTIVITY NUMBER: M05 -021 DATE: 02 -16 -05 PROJECT NAME: JUNCTION - LOT #2 SITE ADDRESS: 14906 MACADAM ROAD SOUTH X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPART ENTS: 3 »OS Bu I ing ivision Public Works ❑ DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -17 -05 Complete Incomplete El Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RTING: Please Route Structural Review Required El No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03 -17 -05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention 0 Planning Division Structural ❑ Permit Coordinator PERMIT COORD COPY Not Applicable ❑ DATE: Project Name: Site Address: A. B. C. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ❑ FILE CO RESIDENTIAL HEATING AND VENTILATION COMPLIANCE FORM (Complete Sections I and II for Group R Occupancies 4 Stories or Less)) MECHANICAL PERMIT APPLICATION NO.: mac-o2( BUILDING PERMIT APPLICATION NO.: :ro to c o lJ - 7Y //906 /e~D,9-in 2D s I. WASHINGTON STATE ENERGY CODE HEATING DESIGN METHOD (select A, B or C House Square Footage (heated space): 23JO X, 20 BTU /h ❑ Heating System Installed, (check system type below): ❑ Electric Resistance ❑ Electric (forced air) g. Other Fuels 63, heat pump) Permit Center /Building Division: 206 - 431 -3670 Public Works Department: _206433 -0179 Planning Division: 206 - 431 - 3670'x. Dos -os� elow): System Analysis — W.S.E.C. Chapter 4 (submit documentation) 0 Of Tukwila Component Performance Approach — W.S.E.C. Chapter 5 (submit documents DIVISION Prescriptive Option — W.S.E.C. Chapter 6 (for prescriptive, complete the following a j calcuftion: 76 Maximum BTU of Heating System Output II. WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (select A or B below): A. ❑ B. _ ❑ Effective: 7/1/02 applications■heating and ventilation system - form h-6 (7.2002) REVIEWED FOR CODE COMPLIANCE 1,DDsQ(vFD JI w — 7805 RECEIVED CITY OF TUKWILA FEB 1 6 2005 PERMIT CENTER Ventilation by Performance or Design Method - W.S.V.I.A.Q. Section 302 (submit documentation). Prescriptive Ventilation Options - W.S.V.I.A.Q. Section 303 (select one of the following): 1. ® Ventilation using Exhaust Fans (Section 303.4.1.) ❑ Exception for outdoor air inlets — Forced air heating system w /interior doors undercut'' h" 2. ❑ Ventilation integrated with Forced Air System (Section 303.4.2.) 3. ❑ Ventilation using Supply Fan (Section 303.4.3.) 4. ❑ Ventilation using Heat Recovery System (Section 303.4.4.) ❑ Prescriptive Minimum /Maximum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form). 1. House Square Footage: Z3c 2. House Number of Bedrooms: 3. Required Outdoor Air Table 3 -2: Minimum - cfm Maximum - cfm C105- OV Floor Area, ft2 Bedrooms Maximum Length Feet 2 or less 3 4 5 6 7 8 70 Min Max Min Max Min Max Min Max Min Max Min Max Min Max <500 50 75 65 98 80 120 95 143 110 165 125 188 140 210 '444•50.1- 100MY,Y 'x;55 "= s 83. .i1711i:: x;10 =!. »' 85: %. 028 ;100:r.. ::150: :..:1.1:5 • .:.:1.7.3': = 4.30'% •195'i= {;145:=` -':218 1001 -1500 60 90 75 113 90 135 105 158 120 180 135 203 150 225 '= 150.12000'; = "'�65 ' r ;;":;98" ; °"•80; ='' - ;•120 .95 :• `::143 x':•1:10 :;81 -.1125 !'::. ‘- . :,',1.40 . ! . .:,:: . 2.11:Y: ;2155=' '233;! 2001 -2500 70 105 85 128 100 150 115 173 130 195 145 218 160 240 :2561 =3000 '.i ' 75?,' ;;11.13 ' .. h90 i'' > ;i1'05! 1;120;= '186.i - •135'; a'203i. 'x,1`50:' i,.. ',165:=: 248::: 3001 -3500 80 120 95 143 110 165 125 188 140 210 155 233 170 255 z's '3501'- 4000 ' ' "x:85 ?" , ::51" , ii`1.00:'' :1:50:, ? ' 173x. x'1.3•=, M'95 ; :V145) ::11.1.8!': '-.:160`1 240:.:1'75. =463 4001 - 5000 95 143 110 165 125 188 140 210 155 233 170 255 185 278 4s `W 5001- 6000t' -1 001.15`01,420 180.4 :, 135's ; 203.E :"1507 „225'{ 465 3"248• ;x.180;' r27.0:'' :;:1.95: .'293x: 6001 - 7000 115 173 130 195 145 - 218 160 240 175 263 190 285 205 308 000:18000xc'L. -.125 ,188' +: } ;14O X210' 1 55 . E ?2 f?:170: ;2552 485 ;• = =,2781 • ' `i200 t?�300; ". , '. 21 '323, 6 8001 -9000 135 203 150 225 165 248 180 270 195 293 210 315 225 338 fdi, > 9000; ` ` YA: 145» " 2i18 i "::160 a :240 .:' ;:;1751 7:263: ':1:90`:` s '•285t . = : 205: x.30 8 ;` 8� ..220: '= „330" = _ `'235 :' ^353. Fan Tested CFM ® 0.25" W.G. Minimum Flex Diameter Maximum Length Feet Minimum Smooth Diameter Maximum Length Feet Maximum Elbows' 50 4 inch 25 4 inch 70 3 �� i ... k "1 .1g +t1 �t i .tis•�.t�.i'.5D.�-:�'.ia.�:_ -t , ilit.'1r. '„v-... •_, 50 ,_.. :.+ S: rnch.. �a; �. .t�...,t�cr.9U. ^:R;! X7.""::9'.. °.�.,.. >��4• . .. ". V:ij � .:'..:5inch�.,�:x��.�.. :i..N .itis'Y. �` .t: `1Z': :�'..<. -... ,700..:.- .,. :.F)q;i';: C +: {•,i :t71! '?.F - '.F'G FM V, r, .. .- _.�.. _a:�,#:�:,,� 50 6 inch No Limit 6 inch No Limit 3 •t y .:aa y �.•. ` 41. - F3 v . , 5 .t�12" ; «Y ;,..,a Y �:k � Sb'_ � . rte ..lt • ti ,, 4 . -1 4.. .,Z ..NT -:..' �^?, ..`i1 c � ...4�inch _. ,Y�.... .vM4r "G.t+: ' , 1 ti `,±3C . ..�.:�. ,NA'� .t ..:: . ,� ::� =•::: "'?ti: 'tii „' n f P �.'.'w t.:x 4 inch...,. f- l 'irx v`. 3i;A �;:�.;:,- ,�r•:�20��i`�::.- qi i �,. � y'.� ' >it. �0 'fry .r.�' ,_3 :c..�,�': :� 'Sce . 1 r,.. 80 5 inch 15 5 inch 100 3 . t ✓�` °i11•i+- .r1 .rlii.:. �� ��, ;� ».,= M,80.:7.s,o-,rte�, i:.•i:; "lifi,:.tii'i h �.,',,.,..,.;6inclt,,.�,.�r -„ J• .? t.1 {.F %g ;' .« i- is - =+ iti'$*1,. ,r.�;._.... -�, }‘Ci ;I:4F''!•1:'. y "i.`is:� � l:a :3:�. <- ...: +.:Crineh.,,��� -�_.. ; :,:.::.: 'h' .•' . f' 3:: a+ K..:. Noli'riiiGl.��r1'.,���.'_,�>,.3 '.4': : : �•". i': •'4s'�. `• •�`�tc :.�-� w•,� 100 5 inch' NA 5 inch 50 3 5 :51.; iii i •� _ N. :.�. 'Ei:.s pc' ,�5....- ;rw�....1'00.,.. <,�:_,., , 4.. i'a - 7..6 .. ...��;.�.t,6`.•irich..�c4.,, Ltr� :;: : '-c:: :r:• :� w . .a. = 4 .., .,. ,., •:r '�:..... , , '_ c :: ( ,4'' .; . . . ....,.6;uich..:�,�..., : roa:. .�� S' �F.�;`: i.�� ... .alloL'•LiniQ;•f.,.,,,» t� . .:1: :;. Y, +4i��:S�',, �� vsr����3::.. >��.�.:.�.:,` 125 6 inch 15 6 inch No Limit. 3 r. r � }� t M .�('� ^'i41�.s'. _115l bi!. . , r 3 . L.l •:v7:rnch =.l. �i� :-�' � :iti f // .� ` ' =.r- r v'.'I. %. Y t.70f!: q ',Gi• , . :Yi''t, ' ''e` :5. L ' a. .. .... .. ..7r tnt.h�... ... . : �f.��' .^_. � . . . ,. i., �e -� � � �'�'� � � "�•,' :_('•1ry Fi'r��. ' r stir ^_.._ .Y -� TABLE 3 -2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) For residences that exceed 8 bedrooms, increase the minimum requirement listed fo 8 bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 times the minimum. =t'ie'r 1'� nri . t ,.., , 1. For each additional elbow subtract 10 feet from length. 2. Flex ducts of this diameter are not permitted with fans of this size. it torii, 1ap�pl'�1 •. slh dy$nlil s -t�� - 1�ZtK12) f r y er ' vac• � TABLE 3 -3 PRESCRIPTIVE EXHAUST DUCT SIZING z z • W QQ � J U O 0 rn C3 J • = H W 0 u_j I-- W ZF 1- 0 W • W D O O ( - 1 2 ' •c W 9 - - O W z O Y2 --- _. O F' z WI- DotJ E S4a rAKI. 4 645 ra12cf-" AIL 141.AVNI4 skis E A M . Coil siattcro i geok g dM R-fkEEM 4'l z14 gairekm 507, c s tMC& -- Gil cmtc. 5p &At.. Goys t oRrok 1 .1Z 1 — 44s GA-s 645 aut./4kc i._ &A3 t,laatR S : unlrrs P.P. & S. Heating & A/C Inc. 12022 98th Ave. NE Kirkland, WA 98034 a Fu oa rPur OF TUKWILA FE 1 6 2005 !PERMIT CENTER /")O o2/ • 'See Residential Warranty Information Brochure for complete warranty information. "40.000 BTU models only. SPECIFICATIONS FrLE copy RHEEmcutr Pius High Performance, Energy Miser® Gas Water Heater REVIEWED FOR IIDE COMPLIANCE Available in 40 and 50 gallon 30 and 40 gallon lowboy mo • 5 -Year Limited Tank Warranty* • 1 -Year Limited Parts Warranty* • High performance and recovery • Patented R -Foam® insulation process for superior heat retention • Gasmaster burner with precision port alignment for even heat transfer • Heat saving flue baffle design P ERmir cE NTER • Compliant with many gas utility incentive programs ** • Meets or exceeds National Appliance Energy Conservation Act (NAECA) requirements ` a FMPfV1TD els JUN - 3 2005 Cif Of itikwila i.11112INcy \ /TST ill Cm AECE oP ruirwrta FEB 1 5' 2005 Gas Input First Hour T i Tank In Thousands Recovery In Delivery . G.P.H. Rating P Numbert ' Cap. 90' Rise E `Gals. LP G.P.H. !App. 'EnergylShpg. Factor i Wght. Lbs. Roughing in Dimensions (Shown in Inches) Hal. 'Burner Nal. LP Nal. LP • A B' C D i E F G H 41VR40 40 40 40 404 40.4 68 68 0.62 127 61%!58%x'21 8 ; 3 131/4 2 1/4 41VR4ON• 40 37.5 — 40.4 — 68 — 0.62 127 : 51% 1581/4 121 8 3 ; 131/4 2 %a A L i 41VR50 ! 50 40 40 40.4 40.4 74 74 10.62 151 160 %157 1/4 123 8 1 3 1 13% 2 1/4 41VR5ON• 50 40 — 40.4 — 74 — 0.62: 151 60% 571/2 :23 8 3 131/4 2 'I 41V30S 30 34 34 34.4 34.4 54 54 0.58 109 501/4 461/4 17% 8 3 131/4 2 Ya 40 37 37 37.4 37 4 65 65 0.56 138 521/4 .481/4 . 19% 8 3 131/4 2 41V50S" 50 40 40 404 40.4 73 73 0.53 140 54 481/4 ' 221/4 8 3 131/4 2 LOW .. 41V40S BOY ' For SCAOMD rule 1121 compliance (California only) " Side relief valve connection on model 41V50S only. 1 Specify LP gas when ordering. Add "P" suffix to the model number. Example 41VR40P A 4V VALVE On MOO WV Ml.f AIM/ VA VI anMMO 40 yr THESE UNITS ARE DESIGNED TO MEET OR EXCEED A.N.S.I. (AMERICAN NATIONAL STANDARDS INSTITUTE) AND HAVE BEEN TESTED ACCORDING TO D.O.E. TEST PROCEDURES AND MEET OR EXCEED THE ENERGY EFFICIENCY REQUIREMENTS OF NAECA, ASHRAE STANDARD 90, BOCA CODE AND ALL STATE ENERGY EFFICIENCY PERFORMANCE CRITERIA FOR ENERGY CONSUMING APPLIANCES. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. The number one choice of plumbing professionals. RHEEM MANUFACTURING COMPANY WATER HEATER DIVISION 101 Bell Road. P.O. Box 244020, Montgomery, Alabama 36124.4020 PRINTED IN U.S.A 3.97 WP RHEEMGLAS® Fury Plus Energy Miser® CONSTRUCTION FEATURES 1. R•Foam Insulation —Rigid polyurethane foam for improved economy and fuel savings. The use of our patented insulator foam stops allows R -Foam to be injected directly between the tank and outer jacket. This uniform R -Foam application minimizes the possibility of costly heat loss caused by uninsulated areas (voids) common to some other foam processes. 2. Rheemglas Tank— Rheem® water heater tanks are made of special materials with exacting care. The tank surface is coated with an exclusive porcelain formula called Rheemglas and fused to the solid steel at 1600'. The result is a smooth, tough, glass -like lining that effectively resists the corrosive attacks of hot water chemicals, thereby assuring long water heater life. Tank is designed and tested to withstand 300 PSI hydrostatic test pressure for working pressure of 150 PSI, A.N.S.I. Standard. 3. Gasmaster Burner — Durable aluminized steel construction. Designed for efficient, quiet operation; precision port alignment; even heat transfer. Factory adjusted for natural gas. LP models feature a durable stainless steel burner designed specifically for LP gas. 4. Flue Baffle —New design — special baffle restrictor discs provide greater retention of flue gases. Keeps heat in flue longer for maximum heat dispersion to tank water. Retards air movement through flue during standby periods, minimizing heat loss. 5. Robertshaws Control— Combination thermostat with factory preset balanced pressure regulation and built in E.C.O. (energy cut -off). LP models feature the R65RR control, the most advanced LP gas control available. 6. Anode Rod — Equalizes aggressive water action; different types factory installed and designed to match local water chemical characteristics throughout the U.S. 7. Dip Tube —A durable plastic formula, tougher, more heat resistant than ever before. 8. Relief Valve Opening —( N.P.T.) top connect is exposed for faster, economical installation. 9. Drain Valve —Non- metallic, corrosion proof, designed for quick draining. 10. The Draft Diverter —Low profile design is proven, efficient. THE GASMASTER BURNER Durable aluminized steel construction. Designed for efficient, quiet operation; precision port alignment, even heat transfer. Features energy saving low input pilot — only 350 to 400 BTUH. Well protected to maintain alignment, yet easy to light. tic.# in keeping with its policy 01 continuous progress and product improvement, Rheem reserves the right to make changes without notice" FORM NO. 101•9 REV. 9 RGLH- SERIES Models with Input Rates from 45,000 to 150,000 BTU/HR [13 to 44 kW] (U.S. & Canadian Models) ENERGUIDE Amid b. uwm NNW, • AFUE MYllt N1 7.% 17% ."1 17% i EFFICIENCY HATING CERTIFIED ama I 78 % -80% A.F.U.E. DOWN FLOW GAS FURNACES : GAS FURNACES been FORM NO. G11 -449 REV. 2 Supersedes Form No. G11 - 449 Rev. 1 aEVIEWED FOR CODE COMPLIANCE Alompewrga JUN - 3 2005 city Of T ui, Jilin CRITERIONgiltNY. DIViSTON t The Rheem® Criterion® II line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by the American Gas Associa- tion. Canadian models are certified by the Canadian Gas Association. Features • Patented Turbulex° heat exchanger, constructed of both stainless and aluminized steel for the maximum in corro- sion resistance. • Low profile "34 inch" [864 mmj design is lighter and easier to handle, and leaves room for optional equipment. • Both standing pilot and hot surface ignition models available. • Left or right side gas and electric inlet connections with quick, simple change. • Hot surface ignition models feature a new integrated board with humidifier and electronic air cleaner hookups. • Insulated blower compartment, a slow -open gas valve and a specially designed draft inducer motor make it one of the quietest furnaces on the market today. • Pre -paint galvanized steel cabinet. • Grab -holes in doors to aid in easy door removal and replacement. A variety of cooling coils and plenums designed to use with Rheem Criterion II gas furnaces are available as optional accessories. tA.F.U.E. (Annual Fuel Utilization Efficiency) calculated In accordance with Department of Energy test procedures. Cfr O r KW ILA - FEB 1 6 2005 PERMIT CENTER MOSP..02/ • • Draft Inducer Motor Hot Surface Ignitor with Remote Sense (Hot Surface Ignition Models) STANDARD EQUIPMENT RHEEM CR. f ERION II 78 -80% DOWNFLOW GAS FURNACE Pilot Assembly (Standing Pilot Models) Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut -off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi - speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; H.S.I. only twinning options, standing pilot models may poi be twinned; fused transformer (secondary), 3rd speed option for continuous tan; common heat/cool terminal for H.S.I. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local installer. Molded Permanent Filter Blower and Control Box Q,nr;r Y�M� Integrated Furnace Control In -Shot Burners and Gas Valve Turbulex•Heat Exchanger All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519 -53 for Canadian models. NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition is 100% lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES -, U. ,i*' ,..y - ;. .. .." 4 04 P4. _ .. ,• O4MAEUSR ' 04 04EAUSR " NAUSR *AO. O EAUSA, 050AUER1; OEMAUE •' O5EAUEf 05'iAUE OW 5EAU 067AUER' l6MAliER: bOEAUER O6NA M 6MAU , 004.0,. OjSAUER 71V)AUER WA* LOU 7AAl�]� WV .075AMGR ;' O7 (O7EAMGR, 0`1NAMGR 15AMGA 7EAMGA' 100AUER. ° ; . `` " , k1OMAUER„r a f OEAMER 10tl AMER OOAUEA' ;, WAWA , 100BRJ]t ; • OEM,, �Oi1 .i= t OEBRJR i ; O BN7 . 00 BR' A EBRJ ! _''? `ir1 as 1 2MARJ(i Jh i2EA %% 2 '; '2 CIA 150ARJR �15MRAttJR WAN' . 15 Input - BTU /Hr [kW] 45,000 [13] 50,000 [15] 67 ,500 [19.8] 0 15;0011122] 75,000 [22) 100,000 [29.3] 100,000 [29.3] 125,000 [36.6] 150,000 [44] Heating Capacity BTU /Hr [kW] ® 36,000 [11] 41,000 [12] 54,000 [16] 60,000,['fjJj' 60,500 [18] 80,000 [23] 81,000 [24] 99,000 [29] 120,000 [35] High Altitude Input [kW] 40,500 [11.9) 45,000 [13) 60,800 [17.8] 67,500;[1._:8] 67,500 [19.8] 90,000 [26.4] 90,000 [26.4] 112,500 [33] 135,000 [39.6] High Altitude Output Capacity [kW] 32,900 [9.6) 36,500 [10.7] 49,000 [14.4] 53,500 1 • j 54,000 [15.8] 72,000 [21.1] 72,500 [21.2] 89,000 [26.1] 107,500 [31.5] Heat Ext. Static Pressure [kPa) .10 [.025] ..10 [.025) .12 (.029] .12 [3)2 }; .12 [.029] .15 [.037] .15 [.037] .20 [.05] .20 [.05] x ' 11 x 6 = 10'AU Blower(D 11x6 [279 x 152] 11x6 [279 x 152] 11x6 [279 x 152] 11 • [279 1 2] 11x7 [279 x 178] [279x152) 11 x 7 = 10*AM 11x10 [279 x 254] 11xi0 [279 x 254] 11x10 [279 x 254] [279 x 178 Motor H.P. [WI- Speeds [WI- 1 /2 -4 -PSC /2 -4 -PSC 1 /2 -4 -PSC 1/2 -4 C. 3 /4 -4 -PSC 1 /z -4 -PSC 3 /4 -4 -PSC 3 14 -4 -PSC 3 /4-4-PSC PSC Type [373] [373] [373] •, ;(3 .r, ; [559] [373] [559] [559] [559] Motor Full Load Amps 7.1 6.8 7.1 1./ 9.5 7.1 9.5 9.5 9.5 Heating Speed MED -LOW MED -LOW MED -HIGH MED I H' MED -LOW MED -HIGH MED -LOW MED -LOW MED -LOW Cooling Speed HIGH HIGH HIGH 1H 0: . • MED -HIGH HIGH MED -HIGH MED -HIGH MED -HIGH Cooling CFM @ .5' [kPa] E.S.P. 1200 1200 1200 11200 1600 1200 2000 2000 2000 (Nominal) [Us] [566] [566] [566] _;r: 1[566 - [755] [566] [944] [944] [944] Rated E.S.P. (In. W.C.) [kPa] .50 [.12] .50 [.12] .50 [.12] .501.12j =. .50 [.12] .50 [.12] .50 [.12) .50 [.12] .50 [.12] 55 -85 =10'AU Temperature Rise Range °F 30 -60 25 -55 30 -60 �4 7 ' O 25 -55 [30.6 -47.2] 40 -70 40 -70 50-80 [ °C] • [16.7 -33.3] [13.9 -30.6] [16.7 -33.3] [22. - 38 :9] [13.9 -30.6] 45 -75 =10'AM [22.2 -38.9] [22.2 -38.9] [27.8 -44.4] 4 ,. `;' [25-41.7] Max. Outlet Air Temp. °F 155 155 165 `' ti65 155 190 190 180 190 [ °C] [68.3] [68.3] [73.9] "�` [68.3] [87.8] [87.8] [82.2] [87.8] Standard Filter [mm] (1)14x20 [356 x 508] (1)14x20 [356 x 508] (2)12x20 [305 x 508] () ,, [3. 2 08] (2)12x20 [305 x 508) (2)12x20 [305 x 508] (2)14x20 [356 x 508] (2)14x20 [356 x 508] (2)14x20 [356 x 508] Approx. Shipping Weight (Lbs.) 85 85 105 b5!; : :. 105 115 120 140 150 [kg] [38.6] [38.6] [47.6] .¢];.. [47.6] [52.2] [54.4] [63.5] [68.0] AFUE- Standing Pilot Models O 78% 79.5% 78.4% 78.6% 79.2% 78% 78% 78.1% 78.5% AFUE- H.S.I. Models D 81.1% 82.2% 80.7% „ $0;5f•;k 81.1% 80.2% 80% 80% 80% California Seasonal Efficiency- H.S.I./No, Models 73.8173.9 75.9/76.2 73.8/73.9 74.4/74.9 75.1/75.5 75.2/75.2 74.7/74.7 75.2/75.3 76.0/75.9 BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EF,F!\IENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS NOTES: All models are 115V, 60HZ, 10. Gas connection size for all models is 1 /2' N.P.T. p In accordance with D.O.E. test procedures. See Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519 -53 for Canadian models for high altitude derate. MODEL IDENTIFICATION- DOWNFLOW MODELS R G L H - Rheem Gas Downflow Design Furnace Series [ ] Designates Metric Conversions Heating Input Designation Standing NOx Electric NOx Pilot Model Ignition Model 045 050 067 075 100 125 150 04M 05M 06M 07M 10M 12M 15M 04E 05E 06E 07E 10E 12E 15E 07E Input BTU /HR A Variations A = Std. Cabinet 04N 45,000 [13 kW] B = be Ca 05N 50,000 [15 kW] Cabinet 06N 67,500 [20 kW] 07N 75,000 [22 kW] 10N 100,000 [29 kW] 12N 125,000 [37 kW] 15N 150,000 [44 kW] U Blower Designation U =11x6 [279 x 152 mm] M =11x7 [279 x 178 mm] R =11 x10 [279 x 254 mm] E Heating & Cooling Designation S =500-1200 CFM [236 -566 Us] Er- 1100 ;1330 CFM (519 -628 Us) G = 1450-1750 CFM [684 -826 L /s] J = 1800 -2075 CFM [850 -979 Us) R Fuel Type R, =Natural Gas, U.S. Standard Furnace A = Natural Gas, Canadian Standard Furnace ! ?'141,1 9. ✓�• 'I!.� 04, 05 1 14 [356] ..., 12 [326] 10 (264] . O � .. 13 • - . t [333] .. 11r1 0 '... : 7I . 4 2) 1 .lit 0 rgNi F1.?-n I � ,. II 1 [25] 3 Y 11 rte, ( 'r r ' jr [76] 6 [152] 2) •rt • 6 I :I; I' . 85 06, 07 17 [445] 16 [415] 12 [308] O 16 /e [422] 0 3 O 0 1 [25] 3 [76] 6 [152] 0 105 [47.6] 10 (A) 17 [445] 16 [415] 12 [308] O 16 [422] 0 3 ® 0 1 [25] 3 [76] 6 [152] © 115 [52.2] 10 (B) 21 [533] 19 [504] 13 [352] OO 201/8 [511] 0 0 0 1 [25] 3 [76] 6 [152] © 120 [54.4] 12 24 [622] 23 [593] 15 [397] 0 23 [600] 0 0 0 1 [25] 3 [76) 6 [152] 0 140 [63.5] 15 24 [622] 23 [593] 15 [397] 0 23 [600] 0 0 . 0 1 [25] 3 [76] 6 [152] 0 150 [68] NOTES: m May require a 3' 176 mml to 4' 1102 mml or 3'176 mml to 5' 1127 mml adapter. DOWNFLOW DIMENSION 26 (676 mm) LOW VOLTAGE ELECTRICAL CONNECTION (HIGH VOLTAGE) -' 26 (681 mm) GAS CONNECTION LEFT SIDE r 1 noclanotac 8Ja8111• r'nns.nrQinnQ 23 203/4 [594 mm) [518 mm] 6 1157 mm) i TOP A —. R.A. 0 0 -- 11 – _it –� I FRONT +— a /a" [16 mm] 3/ [19 mm) BOTTOM x /18 E 34' (864 mm] 1 S.A. -. 19 (502 mm) 3/ i (19 mm) 23 [594 mm] 20 /e" [518 mm] 6 /re" [157 mm) 26 /e" (676 mm) 1 /2" DIA. (13 mm) 7 /e" DIA. [22 mm) • TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] 28 /de" [713 mm) 1 DIA. (35 mm) 20 /a" [511 mm) 24 [621 mm] RIGHT SIDE e / (16 mm) © May be 0' [0 mm] with type B vent. © May be 1' [25 mm] with type B vent. Furnaces must be vented in accordance with ANSI Z21.47-1993 • CAN /CGA- 2.3 -M93 venting table guidelines included with each furnace, and in accordance with local codes. V- I- ' I ;. t ? t I .Yrt ..:J Lam` �; 1h ! ,V �.. LAI 045AUS" 04MAUSR 11 x 6 04EAUS' [279 x 152] 04NAUSR il I , L ., 1/2 [373] ' IIL 7. lt { � .) '[. - -.. -4. LOW MED -LO ME0-HI HIGH i l 685 980 1220 1465 ; . .« - ' , �i [323] [463] [576] [691] • i3,"1 . i1N , 1 , tai 11 ( I x „T L l . , �; R . �l,(F,1) . ,11i:h►VIJ1.L,J,_] 1 •�.�.1 �1. },� \• ' Z it_ - �..1 i..- • ' A l.. �t.i t .:.3 s.I'.:1 [-* � "^'V�.� 650 [307] 615 [290] 580 [274) 545 [257] 510 (241] 955 [451] 930 [439] 900 [425] 870 [411] 840 [396] 1195 [564] 1170 [552] 1135 [536] 1100 [519] 1065 [503] 1440 [680] 1405 [663] 1365 [644] 1325 [625] 1280 [604) ...... F. .J ( � }5. 470 [222] 805 [380] 1020 [481] 1230 [580) 050AUE” 05MAUER 11 x 6 1/2 05EAUE" [279 x 152] [373] 05NAUER LOW MED -LO MED -HI HIGH 735 1025 1185 1345 [347] [484] [559) [635] 715 [337] 690 [326) 660 [311] 635 [300] 1015 [479] 995 [470] 975 [460] 955 [451] 1165 [550] 1150 [543] 1130 [533] 1100 [519] 1330 [628) 1310 (618] 1295 [611] 1265 [597) 605 930 1075 1235 [286] [439) [507) [583] 575 905 1040 1205 [271] [427] [491] [569) 067AUE* 06MAUER O6EAUE" 06NAUER 11 x 6 1/2 075AUE" [279 x 152] [373] 07MAUER 07EAUE" 07EAUER LOW MED -LO MED -HI HIGH 835 990 1140 1300 (394) [467] [538] [614] 820 [387] 800 [378] 775 [366] 750 [354] 975 [460) 955 [451 ] 935 [441] 905 [427] 1125 [531 ] 1105 [522] 1080 [510] 1050 [496] 1290 [609] 1265 [597] 1245 [588] 1215 [573] 720 875 1020 1180 [340] [413] [481) [557] 685 835 980 1140 [323] [394] [463] [538] 075AMG' 07MAMGR 11 x 7 3/4 07EAMG" [279 x 178] [559] 07NAMGR –I- 10EAME* 11 x 7 1/2 10NAMER [279 x 178] [373] { - " - - - Ir ".' 100AUE" 11 x 6 1/2 10MAUER [279 x 152] [373] LOW MED -LO MED -HI HIGH t!i•1' MED -LO MED -HI HIGH r ia7. li MED -LO MED -HI HIGH 1210 1580 1915 — 'k!..} 1070 1240 1420 - 1020 1170 1330 [571) [746] [904] . [505] [585] [670] ' � [481] [552] [628] 1205 [569] 1195 [564] 1180 [557) 1165 [550] 1560 [736] 1550 [732] 1530 [722] 1495 [706] 1880 [887) 1825 [861] 1790 [845) 1740 [821) 2050 [967] 1995 [942] 1940 [916] 1885 [890] 77 - tti9lr P' ; -- • ., ,r.'a .' it ;�.'�':. I. �' i e' 1055 [498] 1040 [491 ] 1010 [477] 980 [463] 1210 [571 ] 1190 [562] 1165 [550] 1135 [536] 1395 1370 [647] 1340 [632] 1305 [61 6] 1155 1465 1675 1835 " - �' 945 1095 1265 (545) [691 ] [791) [866] . ale ' [446] [517] [597] , tj,- `- �s:;!ta$r: [422) [491 ] [547] 1130 1430 1600 1770 . "' 1 905 1055 1220 [533] [675] [755] [835] " ati YM�j [427] [498] [576] <: A : * [406] [470] [526] T [ � 658] •TM..1 ,11}:lt,,. - -'.7 airg. .,eT•iT.i: .- .∎ , r - 7. ' tin 1000 [472] 980 [463 965 [455] 930 [439] 1160 [547] 1140 [538] 1110 [524] 1080 [510) 1300 [614] 1270 [599] 1235 [583] 1200 [566] 1 - I�,iT 895 1040 1160 860 995 1115 100BRJ" 10MBRJR 11 x 10 3/4 10EBRJ" [279 x 254] [559] 10NBRJR LOW MED -LO MED -HI HIGH 1330 1690 — — [628] [798] 1295 [611] 1285 [606] 1245 [588] 1225 [578] 1670 [788] 1655 [781] 1615 [762] 1585 [748] 2085 [984] 2055 [970] 2005 [946) 1970 [930] 2410 (1137) 2355 [1111] 2305 [1088] 2240 [1057] 1205 1565 1945 2165 [569] [739] [918] [1022] 1160 1525 1880 2100 (547] [720] [887] [991] 125ARJ" 12MARJR 11 x 10 3/4 12EARJ* [279 x 254] [559] 12NARJR LOW MED -LO MED -HI HIGH 1330 — — — [628] 1295 [611] 1280 [604] 1240 [585] 1215 [573] 1690 [798] 1660 [783] 1635 [772] 1580 [746] 2090 [986] 2035 [960] 1985 [937] 1930 [911] 2395 [1130] 2335 [1102] 2260 [1067] 2185 [1031] 1210 1535 1850 2080 [571 ] [724] [873) (982) 1175 1480 1785 1965 [555] [698] [842] [927] 150ARJ" 15MARJR • 11 x 10 3/4 15EARJ* [279 x 254] [559] 15NARJR LOW MED -LO MED -HI HIGH 1300 1675 2105 — [614] [791] (993] 1280 [604] 1230 [580] 1205 [569] 1170 [552] 1650 [779] 1620 [765] 1570 [741] 1545 [729] 2075 [979] 2035 [960] 1990 [939] 1955 [923] 2340 [1104] 2290 [1081] 2215 [1045] 2145 [1012] 1115 1485 1900 2080 [526) [701 ] [897] [982] 1030 1425 1815 1995 [486] [673] [857] [942] NOTES: "Designates "R" for U.S. models. and "A" for Canadian models. BLOWER PERFORr ANCE DATA " "Not to be used as a heating speed. Data compiled with factory filters installed. [ ] Designates Metric Conversions D0WNFLOI :. ,MODELS • *FURNACE ` 3 ,;t11VI0T 1 A� ;, ' �(N:;[m ... �' .PLENUM, `tip IDT i� Korth]. ,, VLENUM. '' ` :� tlOWN FLO , . S � � : � N . ,� : r `aw�� ��idWL: •41.•irY:•S:e: " ' `• 0 L. 1 Y ; > ` 1 till M �;((,� .r..:, �ti•� '�1l'•l:1,ra�Y'.)•ia� • , RXAL -B16BU 14 [356) 16 [413] RXAA -C178 14 [356] 20 [514] RXAA-C179 RXAL -B20BU 17 [445] 16 [413] RXAA -C186 RXAL -B16BU 17 [445] 20 [514] RXAA -C180 RXAL -B20BU 17 [445] 21 [549] RXAA -C189 RXAL-B21BU 17 [445] 25 [641] RXAA -C181 RXAL -B25BU • 21 [533] 22 [565] RXAA -C182 RXAL -B22BU 21 [533] 25 [641] RXAA -C183 RXAL -B25BU 24 [622] 25 [641] RXAA -C184 RXAL -B25BU 24 [622] 21 [549] RXAA -C190 RXAL -B21 BU ,COMBUSTIBLE RCO 0 l[ ' 't,i'.a- ::iUSE,W!TH a r. " . , , _ : WA { %E_:SI .E h` y �;;, Fm ' T�^ < a ':;. r i . , !n :w.i'Y ' • r � n !!!N! RXGC -B14 RGLH -04, 05 14 [368] 13 [337] 11 [286] RXGC -B17 RGLH -06, 07, RGLH- 10( -)A 18 [457] 16 [425] 14 [451] RXGC -B21 RGLH- 10( -)B 21 [546] 20 [514] 18 [464] RXGC -B24 RGLH -12, RGLH -15 25 [635] 23 [603] 21 [552] ' ACCESSORIES- DOWrIOW DOWNFLOW WARNING: Unit design is certified for installation on non -com- bustible floor. A special factory supplied combustible floor sub -base is required when installing on a combustible floor. Failure to install the sub -base may result in fire, property damage and personal injury. COMBUSTIBLE FLOOR BASE DIMENSIONS 19 (495 mm] (51 mm] 2" 28 [721 mm] FIBERGLASS 3 LB. [1.4 kg] DENSITY it 4C44C11.b1941‘1Al tu - I` 2/2" '1 I r� (546 11 mm) Before proceeding with installation, refer to Installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. (184 mm] 3" [76 mm] r1I rift �� 1" (25 mmj T FIBERGLASS I 3 LB. [1.4 kg] DENSITY PLENUM OR DUCTWORK 4" (76 mm] (102 mm( NOTE: FLOOR OPENING 21 [546 mm] x B MAX. PLENUM SIZE 19 [495 mm] x C PLENUM DATA — "A" COILS Plenum adapters are required in some instances for use on downflow applications when plenum and furnace size do not match. NOTE: See Form Number C11 -206 for MultiFlex coil data. RXGW -AAA01 Humidifier and Electronic Air Cleaner Accessory Board for Robertshaw Control RBC1 and Honeywell ST9101A 1014 Blower Controls. NOTE: Available for standing pilot models only. RXPF -F01 and F02 FOSSIL FUEL KIT —is for use with Rheem Heat Pumps and Criterion 11 warm air furnaces. RXPF -F02 meets TVA requirements. RXGF -CC* FILTER RACK — Downflow top return mount. NOTE: Filter racks are shipped without filters. "Filters available through the Universal Parts® Department. GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Gas Heat Exchanger Limited Warranty Twenty (20) Years Draft Inducer Limited Warranty Five (5) Years Integrated Control Board Limited Warranty Five (5) Years (Standing Pilot and Hot Surface Control Boards) Any Other Part One (1) Year 'For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. RHEEM AIR CONDITIONING DIVISION P.O. Box 17010, Fort Smith, Arkansas 72917 -7010 In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice." PRINTED IN U.S.A. 8 -96 BP FORM NO. G11 -449 REV. 2 Supersedes Form No. 011.449 Rev. 1 to 0 • ; NOTICE: . IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT.