HomeMy WebLinkAboutPermit M05-030 - BOEING #9-99BOEING #9 -99 9725 EAST MARGINAL WAY S M05-03 0 Parcel No.: Address: Suite No: Contact Person: Name: ANA HERMANSON Address: 1221 2 AV N, KENT, WA Value of Mechanical: $50,000.00 Type of Fire Protection: SPRINKLERS doc: IMC- Permit City ot Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.►va.us 0003400018 9725 EAST MARGINAL WY S TUKW Tenant: Name: BOEING #9 -99 BUILDING Address: 9725 EAST MARGINAL WY S, TUKWILA WA Owner: Name: THE BOEING COMPANY Address: PO BOX 3703 M/S #1F -09, SEATTLE WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N, KENT, WA Contractor License No: HERMACL005B3 MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: ONE NEW EXHAUST FAN AND 3 NEW AIR HANDLING UNITS; REPLACING EXISTING AND 2 NEW AHU (STRUCTURAL WORK UNDER D05 -024 PER KEN) Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 3 Air Handling Unit <10,000 CFM 0 >10,000 CFM 3 Evaporator Cooler 0 Ventilation Fan connected to single duct 1 Ventilation System 1 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 Fees Collected: $730.58 International Mechanical Code Edition: 2003 EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -030 Phone: Phone: 206 575 -9700 Phone: 206 - 575 -9700 Expiration Date :08/25/2006 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -030 04/27/2005 10/24/2005 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 04 -27 -2005 Permit Center Authorized Signature: --e= V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Print Name: doc: IMC- Permit City Vt' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: ci.tukwila.wa.us The grant' g o this per • it d • = not presume to give authority to violate or cancel the provisions of any other state or local laws regulatin . con truction . th erformance of work. I am authorized to sign and obtain this mechanical permit. Signatur- : Date: L1 c9 7) Qt Jana_ Herivonson This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M05 -030 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -030 Issue Date: 04/27/2005 Permit Expires On: 10/24/2005 Date: D ( //a 7/0S- Printed: 04 -27 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 w -IU U0 CO CO LU N w O 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the 2 Building Official. Parcel No.: 0003400018 Permit Number: M05-030 Address: 9725 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 03/08/2005 Tenant: BOEING #9 - 99 BUILDING Issue Date: 04/27/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** g Q 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to = d start of any construction. These documents shall be maintained and made available until final inspection approval is I - granted. z F-- O z i. w uj D 5: All construction shall be done in conformance with the approved plans and the requirements of the International vo Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 01 w W 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. F u- O 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of w Z Public Health - Seattle and King County (206/296- 4932). o _ O~ 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department z of Labor and Industries (206/248- 6630). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 4: Readily accessible access to roof mounted equipment is required. 10: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) doc: Conditions M05 -030 Printed: 04 -27 -2005 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: Local U.L. central station supervision is required. (City Ordinance #2051) 18: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 20: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 21: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** M05 -030 Printed: 04 -27 -2005 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: .� _ 1 Print Name: — \---Verryy3...naY doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 M05 -030 Dateh I,I Printed: 04 -27 -2005 SITE LOCATION Site Address. Tenant Name: Property Owners Name: Mailing Address: P.O acx. 3 11 CONTACT PERSON Name: Mailing Address: Ga 1 Zip ��`` E -Mail Address: Fax Number: c O. 5 . q C) V - ENERAL CONTRACTOR INFORMATION Company Name: g �1�'� 1 C1 ' r A � a'L} ��� Mailing Address: \ \ &f U P1 [ . ‘C) • `�--� -� wa • q s z /� I Cit state Zip Contact Person:I) Lane �C e.. Day Telephone:Lo. 515 • Fax Number: c�a.p. 515.`"1 5C.6 Expiration Date: 0 /no E -Mail Address: CITY OF TUKWILA Community Developmen . bpartment Public Works Departmenr' Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** r- \F E. n. .Building Peer" ` Mechanical Permit.No� 05•—d 30 Public Works Permit No Project or ofce use only) • . 6ao3yD ^ King Co Assessor's Tax S. Suite Number: Floor: New Tenant: 0 .... Yes ®_ Day Telephone: 0Q(0 _515 97 Cib �- wa. City State Contractor Registration Number n( i'`' nn \` } I b 1. - * *An original or notarized copy of "`"'c"""urrent Washington State Contractor License must be presented t the time of permit issuance ** ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: \ y 1 1 E -Mail Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: LI. rafT Mailing Address: , ntact Person: I \f a r) *k ne_r E -Mail Address: \applications'permit application (3.2003) 12003 5 City State Zip Day Telephone: ROC° • (02 3 .0 I Fax Number: 20(0 (o2 . 3 Jv +� 50(-) City Sea ,`--1 1P State C I (� I Zip Day Telephone (o LD2•.3• V1 17 Fax Number: cC O • Cc2 y . 3715 Page I UXk. c 18101 �. Yi C..F,.N �• .Lt Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <I00K BTU _ Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >IOOK BTU Evaporator Cooler 3 -15 11P /500,000 BTU Floor Furnace Ventilation Fan tP� Ventilation System 1 ♦ 15 -30 HP /1,000,000 BTU 30 -50 HP/1,750,000 BTU Suspended /Wall /Floor Mounted Heater Appliance Vent Hood 50+ HP /1,750,000 BTU HeatiRefrig /Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind MECHANICAL PERMIT INFOY 1ATION — 206 - 431 -3670 . MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address:\ l - Contact Person: - 9 Lax - ) \1E Fax Number:aao . 5 ,c4 gcci Contractor Registration Number: ( 2kC1 \C�'5 Expiration Date: / 5(D / * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): S `7.) Ct E -Mail Address: Scope of Work (please provide detailed information): k f iL\.U.* City / State Zip Day Telephone:U(o . 5 - 75 Use: Residential: New ....❑ Replacement ....0 Commercial: New .... Replacement .... ©L Y � P L) +' 2 repI *c . Fuel Type: Electric Gas....❑ Other: • Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD! .F WNE' ,O'.�UTHORIZED AGENT: Signat Print Name. Mailing Address: \ \ (Se x r? r • Date Application Accepted: im-¢ tapplicattonstpctmit application (3.2003) 3/2003 Date Application Expires: 9fc Page 4 Day Telephone: /CC/VT City Date: - . 3 ' ,;-0 ' 1— tt f Po32 State Zip Staff Initials: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payee: HERMANSON COMPANY MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Parcel No.: 0003400018 Permit Number: M05 -030 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 03/08/2005 Applicant: THE BOEING COMPANY Issue Date: Receipt No.: R05 -00329 Payment Amount: 730.58 Initials: SKS Payment Date: 03/08/2005 11:50 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check. 1505 730.58 Account Code Current Pmts 000/322.100 590.46 000/345.830 140.12 Total: 730.58 0679 03/09 9710 TOTAL 730.58 Printed: 03 -08 -2005 Pr � V �e F A —4;i43 GIJ Type of Inspection _ 0 r (.1 A Date Called: ` Spe ial Instructions: �J Date Wanted: c /c t /05 .m. Requester: Pbone No: 7c7Q') L( 7 -Ce2o& INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. 01,05-910 Corrections required prior to approval. Q - -117 - 7 1 ; (; ;4 Date3-9- I lnsPector/ 17 $58.11 REINSPECTI .r FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: • ct . _ Ty of Inspe tion: 0� ,,,,, A res • � �� ' � D ate Ca lled: � q ` Q S ecFal Instructions: T O e Wanted: M--y ` J ,-- C a.m. Requester: O 7 CO 1.p (7 & INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Vi A pproved per applicable codes. INSPECTION RECORD Retain a copy with permit SOS O3Q PER A / , 0.)431-3670 Corrections required prior to approval. COMMENTS: /4-t_ /4 ,,(, //z 7 • ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: `Date: Pc�}ept WI 99'17 TYp f Inspectio 1 Aa e : 7e SpAci I Instructions: L_ Cpl _ / A " � fif„Ii! ° �i1�j1 / . ( Gi // 0,..e.),Z__ e Wanted riflos•-• CO 1 Requester: )- F Pi rP ?; ( - leys. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Approved per applicable codes. Corrections required prior to approval. El $58.00 REINSPECTt FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: 'Date: • "i Proj f--- Type of nspectipn: A / � d ress: r 7 /o2 /` Date Called ; d; O `- / �/ ,� Special Instructions: c ,, t. d . ei-Ze' � / 30 `L (2 Date Wanted: ' . / `-m a.m. Requester: , X7 - .X INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)43 1 -3670 El Approved per applicable codes. th Corrections required prior to approval COMMENTS: I Ae _ezv( 1 Ale/4 (Inspec 'Date: 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: 'Date: ,'ice., . µ; +P - ie • - ;4 0 1 7,7" .- .t , ,Yw ,, ,14.1,44*, `F ':+ �G�'€% �i ; .: - r'Sr. kr K ;,. Project. Name Address 9 City of Tukwila Fire Department p f', Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Alt) „ (.4,/ C 1 ' 9 � ('Retain current:inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Author.ized Date = F INALAPP FRM Rev. 2/19/98 Steven M. Mullet, Mayor' Thomas P. Keefe, Fire Chief Permit No. / s-- (3 3 c Suite # ,T.F.D. .Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206-575-4439 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M05 -030 DATE: 03 -08 -05 PROJECT NAME: THE BOEING COMPANY 9- 9, SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPARTMENTS: BuildI [ ivissio n Public Works CI PERMIT COORD COPY 1 Ii ,DWG 3• ID, th Fire Prevention 0 Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03 -10 -05 Complete / Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS �TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 04 -07 -05 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ri Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PERMIT COORD COPY DESCRIPTION OF WORK: 14V & ELECTRICAL FOR THE UPGRADE Cif THE AiR HANDLING SYSTEMS. 9725 EAST MARGINAL WAY SO'_'TH EL E!NG COMMERCIAL AIRPLANE GROUP P.O. BOX 3707, M /S: 46 -24 SEAT'_E, WA. 9.8124 -2207 PROJECT SUMMARY A: NON: KEVIN RAMBA.LDINI (206) 544 -1479 BU1WING 9- COVER SHEET All 534907 -03 LOCATION IN REGION • • BOEING WORK PLACE SERVICES DEVELOPMENTAL CENTER 9 -99 BUILDING 05 D30 VICINITY MAP PROJECT LOCATION • • BUILDING CODE: SEISMIC ZONE: BARRIER FREE REQUIREMENTS: (NO CHANGE) , OCCUPANCY GROUP: F CONSTRUCTION TYPE: TOTAL BUILDING AREA: GENERAL DRAWING NUMBER 9 -99 -GO M ECHANICAL DRAWING NUMBER . 1 SHEET 9 -99 -M2 9- 99 -HBM10 9- 99 -HBM11 9- 99 -HBM60 9- 99 -HBM61 R 9- 99 -HBM61 9 -99 -RFC! 10 9- 99- RF1411 R 9- 99-- RE1.i11 9- 99- HBM260 9- 99- HBU261 9-99-44310 9- 99 -M500 ELECTRICAL DRAWING NUMBER 9- 99- -RFE60 9- 99 -RFE61 9-99-1E111 9- 99- RFE110 9- 99 -RFE 111 9-99-1E260 9-99-1E261 9- 99 -E519 9- 99 -E520 TR UCTURAL DRAWING NUMBER 9- 99 -RFSIC 9- 99 -RFS' 1 9- 99 -S5CC CODE SUMMARY DRAWING LIST SHEET GO M2 HBM10 HBM11 HBM60 HBM61R HBM61 RFM 10 RFM11R RFM11 RFM11 RFM11 M310 14500 SHEET RFE60 RFE61 1E;11 RFE110 RFE111 1E260 1E261 [519 £520 SHEET RFS1 v RFS 1 1 5513 IBC 2003 EDITION, AS ADOPTED BY THE THE CITY OF TUKWILA 3 II (EXISTING - NO CHANGE) FIRST FLOOR 57600 S.F. (EXISTING - NO CHANGE) SCHEDULES HIGH BAY LEVEL PARTIAL PLAN HVAC DUCTWORK HIGH BAY LEVEL PARTIAL PLAN FNAC DUCTWORK HIGH BAY LEVEL PARTIAL PLAN HVAC PIPING HIGH BAY LEVEL PARTIAL PLAN HVAC PIPING (REMOVAL) HIGH BAY LEVEL PARTIAL PLAN HVAC PIPING ROOF PARTIAL PLAN ROOF PARTIAL PLAN (REMOVAL) ROOF PARTIAL PLAN HIGH BAY LEVEL PARTIAL PLAN FIRE PROTECTION HIGH BAY LEVEL PARTIAL PLAN FIRE PROTECTION CONTROL DRAWING SECTIONS & DETAILS RCk:w PAR'' 1 i P .k RCG* FA 7 AL PLAN Dl; I S TITLE 208Y/120 VOLT POWER PLAN 208Y/120 VOLT POWER PLAN 480Y/277 VOLT POWER PLAN 480Y/277 VOLT POWER PLAN 480Y/277 VOLT POWER PLAN FIRE ALARM AND CMCS SYSTEM FIRE ALARM MCC -1 ANC MCC -2 SCHEDULES IIVAC CONTROL WIRING DiAGRAM PE.`-4.4 CENTER M05 •030 • be • %,1. ( t A A P A A F A A A REV T 6C i Rot Ammo Sit! 900 seen*. 1Pashingtm 90101 -1625 206 623 4717 Fax 206 624 3775 o e4 c • I a r 73 ACCEPTABILITY ms asto MCA* Q!.12.05 01 12_05 01.12.05 BUIWING 9- /EVANSON RECEIVED 01.12.05 L Ni` NO Al 1 R92 AF'RG3 AJAR TAG LOCATION CV -1 HIGH BAY CV -2 HIGH BAY CV -3 HIGH BAY UNIT NO. EFRE2 TAG LOCATION ROOF SERVES Fu OF ROOF AREA SERVED WELD SHOP EQUIPMENT SERVED AHR62 AHRD3 AHRD2 T -3 AHRD3 2 THIGH BAY 30 15 510 650 T -4 ' AHRD3 2 HIGH BAY 30 15 100 250 T -5 AHRD2 2 'HIGH BAY 30 15 510 650 T -6 AHR02 2 _HIGH BAY 30 15 100 250 SIZE QUANTITY SERVICE STEAM STEAM STEAM LOCATION HIGHBAY LOCATION FLOW 810 j /HR 81QJ'HR 810 HR TOTAL MINIMUM TYPE CFM OA CFM CENT 16,500 1.650 CENT 16,500 • 1,650 CENT 16,500 1,650 ESP CFM IN MIG 30,000 1 SUPPLY FAN SECTION RPM 609 E09 609 16 16 16 _ PRESSURE INLET OUTLET PSIG STEAM TRAP SCHEDULE a OV FPM 2338 TSP Ire. WG 2 19 FAN SCHEDULE 2.19 2 19 END CONNECTION THREAD THREAD THREAD BHP £SP MOTOR QTY HP VOLTS PH 1.00 1 15 460 3 12.63 1.00 1.00 OPERATING DESIGN LOAD HR RPM 820 BODY (CAST) IRON IRON IRON 15 15 15 FAN MOTOR HP 460 460 SIZE 1 1 /4` .11/ 1 1 4` VOLTS 460 COLD START —UP LOAD HR ROOFTOP AIR HANDLING UNIT SCHEDULE HEATING COIL STEAM LDS/ ED6 CFM PRESS HR ' F 16,500 30 PS1G 1017 40.0 16,500 30 P510 1017 40.0 16,500 30 P510 1017 40.0 CONTROL VALVE SCHEDULE ACTUATOR ELECT ELECT ELECT PH 3 UNIT WGT 1350 SARCO SARCO SARCO SARCO SARCO BASIS OF DE$:IGN MANUFACTURER MODEL SIEMENS SIEMENS SIEMENS FAN TYPE BASIS OF DESIGN MODEL MFGR SARCO FT -30 FT -30 FT -30 FT -30 FT -30 FT -30 106 ' F 92.9 92.9 92.9 WHEEL TYPE PROP EQUIPMENT WEIGHT L BS 3,986.40 TOTAL FILTERS MBH 945.93 8- 16"X25" 2- 20'X25" 945.93 8- 16"X25" 3,986.40 2-- 20"X25' 945.93 8 -1 6"X25" 3,986.40 BASES OF DESIGN COOK 48 —SUB REMARKS FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC 2.- 20"X25" CURB WEIGHT (LBS 384.30 384.30 384.30 999 30 PSI STEAM / 8 PSI DROP. TWO — POSITION NORMALLY CLOSED ACTUATOR 999 30 PSI STEAM / 8 PSI DROP. TWO— POSITION NORMALLY CLOSED ACTUATOR 999 30 PSI STEAM 8 PSI DROP. TWO — POSITION NORMALLY CLOSED ACTUATOR REMARKS UPBLAST BELT DRIVE WITH CURB AND VFD REMARKS UNIT DIMENSIONS DOWN L W H DISCHARGE AIR IN. IN. IN. DUCT SIZE 138.25 97.00 63.50 31 -1 8 X 31 -1 4 138.25 97.00 138.25 97.00 63.50 63.50 31 -1/8" X 31 -1/4" 31 -1/8" X 31 -1/4" REMARKS CFCI — WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CURB OFCI — WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS. HORIZONTAL STEAM COIL, FAN, AND CURB OFCI _ WITH MIXING BOX, FILTERS. FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CURB • • • O i i E 1601 nth keeve Sake 90C Sep i .x 9! C' -'K 2C* 623 CM F 't 216 A24 37 w Crry O }7.10LA r' _ L' PER AMT C % I• •_i'1111■ :v a a 01.12_05 SWIRL 0!.12 rAi 01.2.06 HIGH BAY PARTIAL HVAC DUCT( BUILDING 9.99 COL e-c .-s IER1TAVON HBM10 2.05 MAINTAIN CLEARANCE ABOVE CRANE RAILS FlELD FA8R1C1TE DN D4SCHAKCi. 45' TYP OF 2 10,000 CFM 3 HP 480V 3- PHASE YAN -BARS ALL AROUND ER ---�. 10,000 CFM 3 HP 480/ 3- PHASE 60'x24 * x13' --0" LONG PLENUM W/5 EA. 48x18 DIFFUSERS 3300 CF1A EA TiTUS 122RS 31x31 UP TO AHRB2 ■8x26 RETURN AIR UP OUTLINE OF AHRB2 ON ROOF 2500 C 24 DU 200 CFM ` - 11 L`1`N 12" OSA 400 GEM [T> 12" DIAMETER OUTSIDE AIR INTAKE DUCT. SEE SHEET M 1 M 10 FOR CONTINUATION DOWN GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES swALE 'ri& • 0 I • S • 1 11C4 TRANSPORTATION AISLE MFG. AREA r PALLET RACK 40123 PALLET RACK 40(123 PALLET RACK 1 1 �ar� x(123 OUTLINE OF AHR03 ON ROOF 60 "x24"x13' -0" LONG PLENUM W/5 EA. 48x 18 DIFFUSERS 3300 CFM EA. TITUS 122RS AIR QUALITY SENSOR AT 5' AFF I HBM 10 M500 TRANSPORTATION 68x26 RETURN 31x31 UP TO AHRD2 AIR UP OUTLINE OF AHRD2 ON ROO 60'x24 "x13' -0" LONG PLENU W 5 EA. 48x18 DIFFUSERS 3 CF)4 EA. TITUS 122RS SW I A4 SSJE FOR Pt?!t' Ot_12_05 0'..12.35 01. f atSION Villa A �►-E 0 s HBMI 1 14 f )c) a 1 TRANSPORTATION AISLE O -1 C 13C1 r 1581 API me' F ShAe ?OC Sea ft. rPasie„ghos 9810 - le t 296: 0717 Fax Allf. 62 a a a t) t)30 L_ - • GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES 1E3 Alt 1 0" 4. 1 $(*- ( trn- P Jfr 1 yrArs 01✓ t t P � ^ E r: �: _ cam PEi M T c"'E T�F, KAY PJ SCA.E NO* I I 1 t N r 0 9f O :.'2-06 01. 12_35 HIGH BAY PARTIAL FIVAC PIPING witE 01.12-06 BUILDING 9-99 oNECHANICAL ER COL. A—C 1-4 OEy_ ENTER, MA o•c MIN 534907 -03 9--99 -160 HBM60 01.12.05 II 2 -1/2" CLWR 90 GPM 2 " CLW$ _ 1-1/4" CLWS & CLWR • f — 2 -1/2" CLWS ie- 2-i/2" CLWR 1 -1/4 " CLWS & CLWR 20 GPM 2 -1/2" CLWS 2" CLWR • 10,000 CFI 3 HP 480V 3 -PHASE MAN -BARS ALL AROUND MAINTAIN CLEARANCE ABOVE CRANE RAILS -- . FIELD FABRICATE ON DISCHARGE 45' FTP OF 2 10,001C C . 3 HP 46CV 3-Pul PENN li1CL Lc:C .5' SP 1-1/4" CONDENSATE 2-1/2"-CLWS CL-WS- T-1 11" CLWS AND CLWR IV IA fl 4 ,b 3 " CLWS &CLWR 51/51 OPENING UP TO EF -7 STEAM & CONDENSATE RETURN UP. SEE COIL PIPING DETAIL. o7 4 r T SI L 3/4" 3" CLWS & CLWR n C • 1-1/4" CONDENSATE 2" CONDENSATE 2-1/2' STEAM 3" CLWS 1 CLW � I on T-1 • 2 -1/2" CS & CR APAO N BAROMETRIC DAMPER f 1 1,/2" STEAM r 1 " CONDENSATE 1; G:W r ;96 14 I SIAN-BARS 0 AROUND 26/14 M 0 _ CLWS • DIFF. 24" 0 2500 CFM (4 PLAACES) c _a0 L 0 0 II 0 601 ►fit: k.erve Sulke 90C SecnR 9e701—'52! 20E 623 c' Fa* 206 624 3 3" CLWR 4 " CLWR , 9 7 0 , izotir) a t44' ' 7% • GENERAL NOTES REFERENCE DRAWINGS 1 09- 099 - 4000 -M4 CONSTRUCTION NOTES SEQUENCE OF OPERATION UH -2 OCCUPIED MODE: THERMOSTAT CYCLES UNIT ON AND OF OPENS OSA DAMPER AND MODULATES CONTROL VALVE TO MAINTAIN SET POINT (65' F OCCUPIED AND 55' F UNOCCUPIED.) SNIT INTERLOCKED WITH SPRAY BOOTH FAN TO START, OPEN DAMPER AND MODULATE 'CONTROL VALVE TO MAINTAIN SET POINT WHEN SPRAY BOOTH STARTS. 2. COOLING WATER SUPPLY AND RETURN PIPING (CLWR AND CLWS) ABANDONED IN PLaCE, 3. HEAT AND VENT: REPAIR UNIT HEATER (UH -2). DISCHARGE DOES NOT ROTATE AND THE CONTROL SYSTEM NEEDS TO HAVE POWER RESTORED. oc C v .•r LA • PES UT CENTER ER 00 / ! F B M6 4 . T ,� Kt t�'..N SCALE: NrC4E • a• a REMOVE STEAM & CONDENSATE PIPING & ASSOCIATED VALVE & CONTROLS cs/cR DOWN • 2" COND RETURN 2-1/2" COND RETURN 2 CS/CR 2-1/2" CHWS/CHWR 21/2 CHWS/CHWR CS/CR I I F 1 led MIA /wove Sal* 9CC Sect*, gostingtor 9e - 24:6 6:3 07 Falt 204 62 r 0 .1205 01.12.05 HIGH BAY PARTIAL PLAt4 INAC PIPING GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PERIAT Ceti MOWN Wildell 534907-03 KE PLA ; scALE: tot 01.12.05 ••• ■••••• 110.111"...• ....711 •11•11• ..............11111••••■••■•••■ "-• - ,• - •■•• - - - •• • •••••• •••. - .p.n. • em .•■••••■•• - ••■•■•■■■••• - •••■■• --••••••••■ -■•■•■•- 110.11..T.11111 ■11. - NIIII.T.1111••• VOW.. ••••• ..1.■•••■•■■• ...11•M • • ••■••• I . NOP • 6" CR 2" CS 2" CS /CR DOWN 6" CR 3" CHS DN TO M1M61/1M61 3" CHR DN TO M1M61 /1M61 4" CR 2 -1/2" CS • 2" COND RETURN ,_" 2-1 /2" se--- +' 1 /4. 6" SEAM 2-1/2" COND RETURN 3' CS 6" CR . a I- 1 I II WY. 2-1/2" CS /CR 2 -1 /2" 4" CWR 2-1/2" CHWS /CHWR �--1 - /4" de,077 2-1/2" CHWS/CHWR • -r T 4" CWS vp a t e ---- 1 -1/4* 7 STEAM & CONDENSATE RETURN UP. SEE COIL PIPING DERAIL CS /CR • 4" CS/CR -r l I AfR 1€0* fie fte Suite IOC SecMe. 1cse+ingtcr ' C = - 525 2CE 6" 'Or/ rcr 206 624 3775 O w REFERENCE DRAWINGS CONSTRUCTION NOTES GENERAL NOTES KEY PLAN 9U L y01E 01.12..06 HIGH BAY PARTIAL PLAN FIVAC PIPING 534907 -03 9-99-10161 Cf.12_05 •4•••■••••• 4,••••••.11.1.... molosn• ■••••••••••• • •••• •-••••••••••••• 1.• ^ "OW 40 EXISTING UNIT HEATER I ".1.11110M. • • .111. ••■■ •••••■■■•■•• •• RO C. 0 SCALE: ISI'= • 4 H • ErSTING VENT x n EXISTING UNIT HEATER AT& TY EXISTING PACE UNIT • R% E 1601 Nth Arena Stale I Sect& 11=tiNIcs 98L1I-1 ?Of 623 O;17 a 20E 624 : A ■ ' ••••••••....- PEisiThier tXNTER ..•-■,,,,_,..•••••■■•••■••■•••• KE PLAN 4 SCALE NW RFM10 t. — we 01.1206 BUILDING 9-99 0CCPINE MASTER OOI. C —E.1-4 RFMIIR 534907 -03 9- 99 —RF'M1 I o;.12C5 O1.12C5 0'.12.05 A ISSL£ F c P'rr r, 534 .7- „ artrisiv4 Ct_ii_t7F REOE!YED C4) v • SCALE t = F ASPO EZAGSF* 0 0 • AERF.FM1 1610 ► 'moue S Re 90C Scolds. Vostington 9310'-1625 20E 523 0 ?17 cax 206 624 37 t)5 o eft• I r , t` CONSTRUCTION NOTES REMOVE DOSING UNIT HEATER & ALL ASSOC ATED PIPING, VALVES AND CONTROLS REMOVE EXISTING EXHAUST FAN PERIAT CENTER ER 111 COIF)** 0 01_12_05 01_12_05 01.12_05 ela 534907-03 too•P No. WV- CENTER wA 9-99-RFIli e • H • EXISTING VENT CHAIN LINK FENCE X x -x -x X x x x X x X x 00 EXISTING VENTS • I I 1601 nth *Patriot Susie 900 Sear*, Washrstor 'G!-165 2% 623 37'7. For 2'X 624 175 • •••• • • I • .0. ••• PF_Iintir CENTER le 17 p SCA!. 'CAE - ■•■•■■•• as, oramMaynonall■ 8 REOCA T WU- 9-CP 13I 222 FOR FONC 610 53490' -43 01.12.05 0;12.35 Ot.12. HIGH BAY LEVEL n WON PLAN B UILDING 9-99 00l. A-C 1 -4 pEV. CENTER. 534907 -03 C' . 1 2.05 C4-) i w • 1" DN TO INSPECTORS TEST • • i I l E 160; Pito home * Side 900 Seal*, Illashirsto,r 9e'3- 2% 623 0 Fes, 2CE 624 7't /2 DN VICTAULIC STYLE 77 FLEX COUPLING SEE 1M260 FOR CONT. 4' DN SEE L4546 FOR CONTINUATION GENERAL NOTES ALL WORK TO CONFORM TO NFPA 13 AND FM. CONTACT BOEING FIRE DEPARTMENT 24 HR. BEFORE STARTING ANY WORK ON THE SPRINKLER SYSTEM ((206 }655 - 7700). PROVIDE ENGINEER WITH RED LINE DRAWINGS SHOWING ANY DEVIATIONS. MARTY (206)655 -7697. REFERENCE DRAWINGS 109 -- 099 -4001 -M2 CONSTRUCTION NOTES Ei>. DUCTWORK SHOWN FOR REFERENCE ONLY. OFFSET EXISTING SPRINKLER BRANCH UNE & RELOCATE HEAD AS REQUIRED TO COMPLY WITH CODES. D>:- PROVIDE DRY SPRINKLERS INSIDE AHRB2 ON ROOF PER FM & NFPA REQUIREMENTS. EXISTING DRY PIPE SYSTEM LOCATED NEAR COLUMN C -1, SEE SHEET HbfB261. 1)1{)t) c!--y r i4:3. V . LiVv PE, ML T Cc �c r 7 / X / BM26 / ./ ///4 /// % : //1 - BM261 r`y VLh 4 S:AL N ! 0 J r: •L� • 01.1205 ACCEPTIIBIIITY gtolcalui �!5 Of.9lir 0 01.12.05 01.12.25 01.12.06 3 23 CONSTRUCTION NOTES C� OFFSET COSTING SPRINKLER BRANCH LINE & RELOCATE HEAD AS REQUIRED TO COMPLY MATH CODES. P PROVIDE DRY SPRINKLERS INSIDE AHRD2 & AHRD3 ON ROOF PER FlJ & NFPA REQUIREMENTS. IXISiING DRY PIPE SYSTEM LOCATED NEAR COLUMN C -t. OWE 07./2.05 SV --934 IVIIVIIVIIVIIVI IAIIAIIAIIAHAI 1VIIVIIVIIVIIVI IAIIAIIAIIAIIAI 60r F �i t Avenue Sute 900 Seat`•ie, Iasli Npar• 98 2Cf €23 0 fa• 206 62. 3' 3"DNTO DRY SYSTEM 2-1/2" DN TO DRY SYSTEM SV -933 8" RISER GENERAL NOTES ALL WORK TO CONFORM TO NFPA 13 AND FM. CONTACT BOEING FIRE DEPARTMENT 24 HR. BEFORE STARTING ANY WORK ON THE SPRINKLER SYSTEM ((206)655 - 7700). PROVIDE ENGINEER WITH RED LINE DRAWINGS SHOWING ANY DEVIATIONS. MARTY (206)655-7697. RECErVED REFERENCE DRAWINGS 109 - 099 -M2 • • Am- • • • is y 01.12.05 01.12..06 irLs 01.12.05 Ad oak 534907-03 534W?-03 : Pt O' . T 2.0'5 ROOF EFRE2 TO FMCS &VFD EXHAUST FAN CONTROL DIAGRAM SCALE % AE • DIFFIRENTIAL TO ATMOSPHERIC PRESSURE PRESSURE MEASURING STATION SPACE FAN PLY TEMPERATURE SENSOR A:R QUALITY METER FMCS (EMT ;N G) ----4 TO BUILDING PRESSURE -•--- -- TO EMCS TO EMCS TO EMCS SCALE *Of TO EMCS MOTOR CONTROL SA • TO EMCS SEQUENCE OF OPERATION FOR AHRB2, AHRD3, AHRD2 AND EFRE2 AiR HANDUNG UNITS WILL PROVIDE MAKE -UP AIR FOR THE WELD SHOP EXHAUST FAN AND TEMPERATURE CONTROL FOR THE BUILDING. AIR HANDLING UNITS WILL RUN DURING OCCUPIED HOURS. WELD SHOP EXHAUST FAN (EFRE2) WILL BE STARTED AND STOPPED BY THE EMCS AND WILL RUN DURING OCCUPIED HOURS. INDOOR AIR QUALITY METER SHALL MONITOR WELD SHOP AIR AND START EXHAUST FAN, AND CONTROL THE FAN SPEED AS THE AIR QUALITY WORSENS. AIR HANDUNG UNITS WILL RUN WHENEVER THE EXHAUST FAN IS RUNNING, AND BRING IN OSA TO MAINTAIN POSITIVE BUILDING PRESSURE AS MEASURED BY THE BLDG/ OSA MEASURING STATIONS AT EACH AIR HANDLING UNIT. IF THE EXHAUST FAN IS OFF AND THE BUILDING SPACE TEMPERATURE FALLS BELOW 60 DEG F, THE AIR HANDLING UNITS WILL START TO MAINTAIN TEMPERATURES IN THE 60 DEG F RANGE. ON A CALL FOR HEATING THE TWO - POSITION STEAM VALVE SHALL OPEN, AND THE HEATING COIL FACE AND 9YPASS SHALL MODULATE TO PROVIDE TO MAINTAIN SPACE TEMPERATURE. ON A CALL FOR COOLING AND THE OUTSIDE TEMPERATURE IS BELOW 40 DEG F, THE TWO POSITION STEAM VALVE SHALL BE OPEN AND THE FACE AND BYPASS DAMPER SHALL MODULATE TO MAINTAIN SPACE TEMPERATURE. WHEN OUTSIDE TEMPERATURE IS ABOVE 40 DEG F, THE TWO - POSITION STEAM VALVE SHALL BE CLOSED. UPON DETECTION OF LOW TEMPERATURE CONDITION OF 35 DEG F DOWNSTREAM OF THE HEATING COIL, THE MANUAL RESET LOW TEMPERATURE SWITCH (LTS) SHALL SHUT OFF THE SUPPLY FAN, CLOSE THE OUTSIDE AIR DAMPER AND OPEN THE STEAM VALVE. SMOKE DETECTORS SHALL COMMUNICATE WITH THE FIRE ALARM CONTROL PANEL. UPON A SIGNAL FROM THE SMOKE DETECTOR, THE SUPPLY AIR FAN SHALL STOP, THE OA DAMPER SHALL CLOSE AND THE RA DAMPER SHALL OPEN AND THE STEAM VALVE SHALL. OPEN. ADJUSTABLE DIFFERENTIAL PRESSURE SWITCHES SHALL DETECT A DIRTY FILTER CONDITION, AND GENERATE AN ALARM TO THE CMCS SYSTEM. POINTS TO BE MONITORED / CONTROLLED EACH AIR HANDUNG UNIT SUPPLY FAN S/S . SUPPLY FAN STATUS LOW TEMPERATURE SWITCH SUPPLY AIR TEMPERATURE FACE AND BYPASS DAMPER TWO POSITION STEAM VALVE FILTER DIFFERENTIAL PRESSURE SWITCH MIXED AIR TEMPERATURE RETURN AIR TEMPERATURE OSA / RA DAMPER ACTUATOR OUTSIDE AIR MEASURING STATION WELD SHOP VFD S/S VFD STATUS VFD SPEED CONTROL VFD RPM FEEDBACK BUILDING / OSA PRESSURE DIFFERENTIAL WELD SHOP AIR QUALITY METER TO E1105 FMCS LOW SUPPLY LOW SUPPLY LIMIT MR LLTS TT TO EMCS- TO EMCS --- , F&BP r DMPR I r I i T -X T -X --- 4-�- -4 S SEE COIL PIPING DETAIL FILTER AHRB2, AHRD3, 8 AHRD2 CONTROL DIAGRAM 4 MIXED AIR TT I ' I NO' FM hankie Smite 900 Sed'Je. **.49..z 9e•0'-! `_ 2X 623 C0 F* 206 ke 37 IV' *ft-03c) \- SMOKE DETECTOR & CONNECTION TO FIRE ALARM SYSTEM BY ADT. U OA _ PE.M a . • • WSUE Ft* PERMIT/VC 5M7-C3 COMM GE. 12.05 AIME71107* 01.12.05 01.12.05 01.12.05 BUILDING 9-99 proms rim). 534907 -03: ICOIP JO. ND 534;7-03 s- i • CURB -� FLASH do COUNTER FLASH SEE STRUCTURAL FOR SUPPORT 2 x 1 z' -Cj F EN; Y 4 x'S St;+- Car.:1'SE° ';art r' Sri 1 4ChE AHU 31x31 SA DUCT TYPICAL AHU SECTION (TYP) !r r AHU CABINET SEE PARTIAL PLAN VIEW FPR EXISTING STEAM & CONDENSATE SIZES r STEAM COIL STEAM COIL s:' Kit MPR (30) LIPS (30) r~+- 4D -- yo- 2 (SEE SCHEDULE IFOR SIZE (TYP) l 1 -1/ 2 r AHU STEAM COIL PIPING DETAIL (TYP) 1)5ftopy) f VACUUM BREAKER 2-1/2" CV - x I N _I z - 3/4' T - 3 /4 0 e I P14 Ain F l 160! Fah Avenue Suite 9CC Ser.'tlle. licatiectat 9E3-'2 _c6 623 0717 c= 2C6 624 "!. 7 - 2 --1/2 `- P I � /-2 -1/2' ROOF PENETRATION (TYP) • C:'v ar_:. �:;: PEA 44:7 ti = I. h ein Zit • • BUILDING 9-99 - • EXISTING UNIT HEATER ! „ , —�, • ' Gtl 19 W • � EXISTING r VENT r _ r _ EXISTING UNIT HEATER w m EXISTING PACE UNIT • LEGEND: C -41 -Y _ r UJ% F&We - 7 CENTEP VI 480 VOLT RECEPT., 3- WIRE, 4 -POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. J -BOX 480/277V DISTRIBUTION PANEL �► TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN - GROUND 480V 3 PHASE MOTOR MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC MOTOR STARTER, MANUAL DISCONNECT SWITCH, NON- FUSED, XX AMPERES MACHINE /EQUIPMENT NUMBER X, Y HORSEPOWER GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE 112 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 12O/208V 277/4801/ 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE ((ENTER BUS IN PANEL) RED ORANGE 'C PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE RDJ NED BACK TO SOURCE INCLUDING PLUG —IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., vim CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. DP- CONSTRUCTION NOTES: PROVIDE RECEPTACLE AND BRANCH CIRCUIT. PROVIDE A COMMON 1 20V CIRCUIT FOR CMCS CONTROLS. FINAL CONNECTION TO CONTROLS WILL BE BY CMCS CONTRACTOR. L_ 1 r- .•• . ` E.. A \ • • • • EXISTING VENT CHAIN LINK FENCE 1' i M • • • • • • 4. • • • • • • • • • • O O EXISTING VENTS • • • • . I • • • w E r t „. • R ,r V • LEGEND: C) • _t_ GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2' E1iF UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE 912 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR COOtIG OF CONDUCTORS SHALL BE O8SER11ED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V 'A' PHASE (LEFT BUS IN PANEL) BLACK BROWN •B' PHASE (CENTER BUS N PANEL) RED ORANGE 'C' PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHIR GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) All UNUSED CONDUIT AND WIRE TO BE RE* NED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7.) DniO LIBEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC.. WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF J08. CONSTRUCTION NOTES: PROVIDE RECEPTACLE AND BRANCH CIRCUIT. PROVIDE A COMMON 120V CIRCUIT FOR CMCS CONTROLS. FINAL CONNECTION TO CONTROLS WILL BE BY CMCS CONTRACTOR. r ;it .7.••• vim. - I `. •_ •JIr. • ` 480 VOLT RECEPT., 3 -WIRE, 4 -POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. J -BOX 480/277V DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND 480V 3 PHASE MOTOR MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC MOTOR STARTER, MANUAL DISCONNECT SWITCH, NON - FUSED, XX AMPERES MACHINE /EQUIPMENT NUMBER X, Y HORSEPOWER ft? t SrV 20KVA X -F0 — Varna EXHAUST FAN 1HP,460V,30 F Dec MFG f, I � 1. f Mr aMSTRUCTION ▪ RELOCATE 9-101 ALL SHOP 3/(C -3110 DOIAUST FAN 1IP.460V,30 D4/6 N (IElcx:ATE 11ORAlRx SHOP D-4 1/t�il TIELL1ING AIRDS 0E/1 TO sue f5 a 25 IV HEAT 200 PUMP TOP ON _ _ 1 -1 /2'C CEILING r 13,15,17 L MOTORIZED ROLL-UP DOOR 1-1/2 HP, 460V, 30 B 30 3/4" 3#10 D4/6 2 -1/2 i 3)114/0 & T OF PUMPS) PLUG —IN BUS D3.5 800A 600V GE CAT jDE1 A38 rC, TRANSPORTATION AISLE vet-3110 PNL C3.3 2'C, 33/O 41302M -n .41130240-40 HYD PUMP 3i1/0 D4/2 C3.1/7,9,11 C3.1/32,34,36 2'C -13/0 1 1/2 C3.1\1,3,5 2'C,3 -f3 /0 • 11 S1 i/ii " /i Q _ I I E ,l . N NI NM IN 11111 MIMI 1111111111111! 'MI No LIM W._1 pro INMI 'E ■ 1 ,► _ Band Saw 4.4A,460V,30 3/4' 3#10 T RAC 30 5 1- 1/4'0, 316 D4 /7 ' 3/4 "C 3110 • 15 30 ME 23 1o/3o 1 /2'C, 3f 10 S0 1 2 I ■ A 7EA WIT3 #55 *30433» PRS 11 x 12, 04/1 1 314 s j1 304330r I SN1TC 5 i WINK 2n104 i 133232-0 , ' I WAVY 03.16,04 06.02.0. 10. 144 "I NSI IX1 RACK 41t(121 C - 35 37 39 / 4'C318 7 J D4 3/4'C 3f10 2-1 VC (6 2/0 3/4'C, EMPTY 1- 1 /4 "C, 314 3/4'C, 3110 2'G 3 F / 2'C -3#3/0 C3.2 1 1/2 1'C (3)14 1- 1/4'C,314 PNL. E3 It FEEDER 1SSUE FOR PUMAS 2- 1/2'C, 1 V 200 100 100 00 SHEAR 3 H P 460V,30 E3-7/3 1 "C 314 PNL. C3 PNL. E3-7 3/31a,39b,41c 2.4,6 E3 --7/3 3/4'R 3110 E3-7/5 3/471 3110 (3-7/1 1713#4 E3-7/8 3/4'R 3#10 E3-7/7 3/4"R 3110 2'C -12 C3.5/20,22,24 26,28,30 (3- 5/8,10,12 • 1 -1/4'C -314 TO CRATE FEEDER Jr134907 --03 0 O 0 3 I060 30 1 2-83 i - -- ---� .L - -J C3.5/2.4.6, 8,10.12. 1- 1/4'C,31+4 L r 1 1 Do • COMM 0112.05 T r _ - - - - _ � I 2'C -12 1- 1 /4 "C -f2 2'C - 1 7 6'RIQD CONDUIT IN 1'-0" DEEP TRENCH 3/4" CO fi 1 . 2 1 C, 313/0 CU TRANSPORTATION AISLE 1- 1/4'C -3#4 UP TO CRANE RAYS (3 TYP.) 2, Tor's4XFIJR 1 • iQ 20. 22, 24 110 8,10,' 26.2& 60A CRANE DISCOI N T SWITCHES 1- 1/4'C,312 1- 1/4'0;314 /OE /ADO• • 1- 1/4'C, 3#4 1- 1 /4'C, 314 1'C -30 E2 -1/1,3 3/4' 600 P (2- 1/2,4 3/4' 6110 1E110 CRAKE POOR RUN -WAY CONDUCTORS ¥•(-1 2.2114 E E506 1'c,316 3 4 1 ■ 2 4 1 APPIIINED 9 11 .� 3112(OE) 0 COI.. D/2 110 ■ AC CEPTABILPY l 5 I 1 _ *.,'TOR SPECIPOMON 5 OPPMEC if 1 1' 3 -ANN 15 KVA,480V,30 TO ` TRANSFORMER 30 KVA,480V,30 TO 120/208V,30,4W TRANSFORMER 0 MOTORIZED ROLL-UP DOOR 1 HP, 460V,30 PLUG -IN BUS D1.5 400A, G.E. TAPE DE RANSPORTATI Too 3/4'00 1- 1/4'00 rc0 F1/1,3 -- 3/4" 6f10 GANTRY CRANE CONTROL. PANEL 0 ' 3 , PNL. C1 11C UMW d -30-98 11102/ se 11 N2 1• ,#10TO MCC 82 LOCATED AT EQlAPUENT PLATFORM A NEMA 3R SWITCH TYP. OF (3) —F1 2 3 4' 3110 1' 4110 DWG. M543, M544, M545 FOR WRING DIAGRAM 0 0 a b a • 4$OY/277 VOLT rowan CONSTRUCTION NOTES: 1>• DISCONNECT EXISTING MECHANICAL UNIT LOCATED AT TRUSS LEVEL. REMOVE CIRCUITRY BACK TO SOURCE. 1'4 D5ftwg- 1)30 .• REMOVAL DRAWING BUILDING 9-90 ELECTRIC/4_ MASTER COL C-E 1-4 LEGEND: 1 40 480 VOLT RECEPT., 3 -WRE, 4 -POLE, CROUSE HINDS, TYPE ARE, XX AMPERES J -BOX • TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN ▪ GROUND 0 480V 3 PHASE MOTOR ® MOTOR STARTER, MAGNETIC y0. MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH ® MOTOR STARTER, MANUAL ,w ;0 DISCONNECT SWITCH, NON- FUSED, XX AMPERES �-- MACHINE /EQUIPMENT NUMBER X, Y HORSEPOWER r GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE /12 TWIN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V 'A' PHASE (LEFT BUS IN PANEL) BLACK BROWN 'B' PWSE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH 00 NOT HAVE COLORED JACKETS SH*L.L BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND I RE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG -MI CIRCUIT BREAKERS ON BUSIMAY. 6.) FEEDERS TO PANELS AN40 BUSWAYS SHOWN ON SHEETS E2 AND E3. 7.) DYMO LABEL. All RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC.. WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REIASED PANEL SCHEDULES UPON COMPLETION OF JOB. • rrc. = 7_ '- • PEr C c- - cQ ti RtCEI .tD L FEB M x Y • D.C. 480/277V DISTRIBUTION PANEL IA » 534907 -03 'KEY PLAN 534907 -03 1 0 04- 099-1 E111 t '1 o- Sri 0:.12.06 1801'/171 VOLT PER PLAN BUILDiNG 9 -99 aFCTwcK wsror ooi. A-C 1-4 �� 3 , A 01.12.05 RFE110 COMP a. 14111. 9- 99--RF Ei 10 EXISTING UNIT HEATER ail EXISTING EXHAUST 2 1'C -3 2#14 0C YCC -2/C3 • • EXISTING VENT EXISTING UNIT HEATER EXISTING PACE UNIT -- • CONSTRUCTION NOTES: PROVIDE BRANCH CIRCUIT, DISCONNECT SWITCH, AND FINAL CONNECTIONS TO AIR HANDLER. TOP OF SWITCH SHALL NOT EXCEED THE HEIGHT OF THE AIR HANDLER. 05' . • t. FEAM i • LEGEND: • 480 VOLT RECEPT., 3 -WIRE, 4 -POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. J-- BOX 480/277V DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND 480V 3 PHASE MOTOR MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC MOTOR STARTER, MANUAL DISCONNECT SWITCH, NON- FUSED, XX AMPERES MACHINE /EQUIPMENT NUMBER X, Y HORSEPOWER GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2' EUT UNLESS OTHERWISE NOTED. 2.) AU. WIRE TO BE #12 THW 1 UNLESS OTHERWISE NOTED. 3.) THE FOLLCM NIG COLOR COOING OF CONDUCTORS SHALL 8E OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480N PHASE LEFT BUS IN PANEL) BLACK BROWN 'B' PHASE CENTER BUS IN PANEL) RED ORANGE 'C PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG —IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7.) MAO LABEL ALL RECEPTACLES, JUNCTION BOXES, SNITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. • 000 RfE110 0 I RFE111 ; RFE 112 KEY PLAN . cpu: mold( X I a mo- w 1*C-3#8,414 & 1#10G MCC 1*C-3#8,2#14 & 1i1OG MCC-2/B4 EXISTING VENT CHAIN LINK FENCE 01.10.05 CONSTRUCTION NOTES: D>. PROVIDE BRANCH CIRCUIT, DISCONNECT SWITCH, AND FINAL CONNECTIONS TO AIR HANDLER. TOP OF SWITCH SHALL NOT EXCEED THE HEIGHT OF THE AIR HANDLER. 4480W2T7 VOLT POWER PLAN 480 VOLT RECEPT., 3-W1RE, 4-POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. J-BOX ZI 480/277V DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN 4. GROUND 480V 3 PHASE MOTOR la MOTOR STARTER, MAGNETIC Le MOTOR STARTER, MAGNETIC Li MOTOR STARTER, MANUAL rA i NF L0 DISCONNECT SWITCH, NON-FUSED, XX AMPERES sED MACHINE/EQUIPMENT NUMBER X, Y HORSEPOWER LEGEND: 1.) ALL CONDUIT TO BE 1/2' INT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 IFIVIN UNLESS OTHERWISE NOTED. • 3.) THE FOLLOWING COLOR COOING OF CONDUCTORS SHAU. BE OBSERVED ON ALL aRcurrs 600 VOLTS OR LESS. 120/208V 277/48CN 'A* PHASE (LEFT BUS IN PANEL) BLACK BROWN PHASE (CENTER BUS IN PANEL) RED ORANGE 'C' PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE sat CONDUCTORS WHICH 00 NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE f3Y APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE INCLUDING PLUG-I4 CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND £3. 7.) Dna Lei ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC.. WITH CIRCUIT 10041IFICA11ON. B.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. GENERAL NOTES: DUE 0' 12_05 9-99-RFE111 wet 01.12_05 BUILDING 9-99 ELECTRICAL WeSTER COL C -4 OM CENTER. 11A RFE110 KEY PLAN sue- Kw • • • IN li PPOK II D 4 ! 10737 WAS 1c 110737 WS ANS 11073700 1ES NS 110737 MSS MS 18S INS 10/07/02 3/25/03 4/8,/03 5/9/03 9/04/03 FIRE ALARM AND MC8 SYSTEM BUILDING 4•.1 solsos 534907 -03 11073700 • • H q 4 4 vet! ¶ t a Q CONC. PAD. SEE STRUCTURAL DWGS. (TYP.) W1 M MFG. AREA sag Ye. r W2 11 PAL LET f r . – o r .r • 4JX1%. 500 0 0 iCiP FLOOR PLAN 13* = - -f - - yf .r -r C) • IMO s •,II 11■11 1111111Mra \ At ILL 1/2' 1-4 J18 (RED ( RED HYD. P[PA'R SHOP ' 11A1 3D 320 k',' VAULT { 12B1 3 FOR CONTRA AND WANG DIAGRAMS SEE ; i MECHANICAL DIGS. Y543, W544 Y545) • I 3 (FOR CCN1R1 MID MANG WOWS IE'.:NANICAL ?GS W543. W544, 15 45) • it �y V. VE INDFATCH 4 4 - 0 1/2 ", 3114 N 3/4" 9114 NI 3/4 12114 Ii ' pTQ. dDT LIONIrDR PMEL AT COL. Dl C - 9.) PROVIDE INTERLOCKS FOR THE DUST COLLECTOR, TABLE SAW, BANDSAW, DISC SANDER AND DRILL PRESS. REFER TO SHEET E501 FOR SPEC WIRING AND INTERLOCK REQUIREMENTS. APPLY TO BOTH NORTH AND SOUTH DUST COLLECTOR. ®cRU UNITS ARE LOCATED AT EQUIPMENT PLATFORM LEVEL OCRU UNIT IS LOCATED INSIDE DROP CEILING. 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. GENERAL NOTES: 1.) ALL CONDUIT TO BE 3/4' EMT UNLESS OTHERWISE NOTED. 2.) ALL WRE TO BE X12 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG —IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 LEGEND: SD HVAC DUCT SMOKE DETECTOR N VALVE INDICATOR SWITCH ` A` PHASE (LEFT BUS IN PANEL) BLACK BROWN ` B PHASE (CENTER BUS IN PANEL) RED ORANGE ` C` PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE • GRAY EQUIPMENT GROUND GREEN D5-030 "LA • I • r 1 i — , TRANSPORTATION AISLE MFG. AREA PALLET RACK PALLET RACK •ox,23 41 A !t �A 1 RD3 ROOF PALLET RACK 40X123 fI . /4' C.O. TO ADT PANEL, COL. Dt x 4 I- 0 0 L �o o .._ _ i IN IN O i O I O o S 1111 L i L Im mi on a S .. IN \AIIIMMiliMMINEMIIIIMMINIIIIIIIIIHIVI :,ALE: 7 /45 / -3" a TRANSPORTATION AISLE • AREA 18B1 13C1 4 • • 4 4 • • • 4 . r • • • • • • • OPEN AREA 3 Me'f VAULT 15E31 j 4 4 VAHRD 2 � 3/4' C.O. TO ADT PANEL, COL. D1 S • 158 12 A • 4 4 . TRANSPORTATION AISLE 0 OPEN AREA 11C VESTIBULE lici ADT PANEL )"1 CONSTRUCTION NOTES: PROVIDE J —BOX, RACEWAY AND PULL STRING. COORDINATE J —BOX LOCATION WITH ADT. rt� b 5•03d _ I P • r i . r • J . •-) J t- r Li 1 , r . 2 $ • C r LEGEND: GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. THE FOLLOWING MATERIALS IN THE AREA ARE ASSUMED TO BE POSITIVE FOR ASBESTOS: 1. HARD FITTINGS ON FIBERGLASS PIPE RUNS 2. MAG PIPE INSULATION 3. FLOOR TILE AND MASTIC (12 1 2" WHITE /BROWN) 4. FIRE DOORS 5. MUDDED FIBERGLASS TANK INSULATION EJ KEY PLAN 9COLS: ROE I. • H a I MOTOR CONTROL CENTER . EQUIP. NO. CIR- CUIT J. DESCRIPTION MOTOR CIRCUIT BREAKER MOTOR STARTER REMARKS HP VOLTS PHASE AMP TRIP POLE FRAME SIZE COIL LIGHT C QIVT�CTS COIL CONTROLS N.O. N.C. LOCAL REMOTE BLANK Al SPARE Al 2 _ 2 EXHAUST FAN EF -3 1/2 HP , 3 COOLING TOWER FAN F -2 SPARE SIZE 1 3 3 EXHAUST FAN EF-5 SUPPLY FAN AH -1 20 HP 3 SPARE SIZE 1 3 AH -2 A2 COMPUTER SUPPLY FAN 15 480 3 40 , 3 THEF 2 120 R 3 1 3,4 3 INTERLOCK w/ FIRE ALARM RELAY EF -3 A2A EXHAUST FAN 1 /2 480 3 15 3 THEF 1 120 R 2 2 3,4 SEE E520 FOR CONTROLS LOCATION AH - 1 A3 OFFICE SUPPLY FAN 20 480 3 70 3 THEF 2 120 R 3 1 1,4 7 INTERLOCK w/ FA REALY & FREEZE STAT. EF -1 A4 EXHAUST FAN 15 480 3 40 3 THEF 2 120 R r 3 1 1,4 � INTERLOCK W/ AH -1 r P -10 A5 CONDENSATE WATER PUMP 205 480 3 20 3 THED 3 THEF - - -- - DUPLEX STARTER W/ PUMP, 1ST FIR F/4 PU3G3A 61 BOOSTER PUMP 2 480 3 15 3 THEF 1 120 •- r- � N 10 I 120 120 72` " 120 CI IX CC F + I+H 1 1 SPARE 82 1 SEE E520 FOR CONTROLS LOCATION - - - 15 3 THEF 1 120 R 15 EF -12 `tFv4 ~ AHRB2 ... C1 2 C3 EXHAUST FAN NHAtfSl F--N .r v v vv v AIR HANDLER _ ., SPARE B3 THEF '' - I - - 15 3 ' THEF 1 120 R 2 2 SPARE B4 CONTROL TRANSFORMER - - - 15 3• THEF 1 120 R 2 2 1 � SPARE Cl 1 -- - 15 3 THEF 1 120 R 2 2 1,4 SPARE C2 - - - 15 3 THEF 1 120 R 2 2 1,4 5 MCC-2 C3 BLANK C4 SPARE C5 SPARE C6 - - - 20 3 THEF 1 120 R 3 2 P -8 D1 COOL WATER PUMP 125 3 TFK 3 120 R 3 1 1 1 F -1 02 COOLING TOWER FAN 125 3 TFK 3 120 R 3 1 F--2 03 COOLING TOWER FAN 125 3 TFK 3 120 R 3 1 F -3 04 COOLING TOWER FAN 125 3 TFK 3 120 R 3 1 F-4 05 COOLING TOWER FAN l''5 3 TFK 3 120 R 3 1 CT -2 06 COOLING TOWER PUMP i 25 3 TFK 3 120 R 3 1 1 SPARE 4 E1 - - - 15 3 THEF 1 120 SPARE £2 - - - 125 3 THEF 1 120 SPARE 0 - - -- 125 3 THEF 1 120 £4 I , y E -� ♦ 1 1 1 1 1 j V2 I y 1 I I:4 h r � - 1 MOTOR CONTROL CENTER EQUIP. NO. CIR- CULT NO. DESCRIPTION MOTO " D CIRCUIT BREAKER _ MOTOR STARTER REMARKS BLANK HP VOLTS 'HASE AMP POLE FRAME SIZE COIL IND LIGHT AUX CONTACTS CONTROLS N.O. N.C. LOCAL REMOTE SPARE Al 2 _ 2 EXHAUST FAN EF -3 1/2 HP 2 3 COOLING TOWER FAN F -2 SPARE SIZE 1 3 3 EXHAUST FAN EF-5 SUPPLY FAN AH -1 20 HP 3 SPARE SIZE 1 3 MCC -2 3 4 COOLING TOWER FAN F -3 UH -1 Q � � Cn m M UNIT HEATER I N H . T ' AIR HANDLER UNIT HEATER ,UHLT J4EAtER� .� .. A ,. , _ . COOLING TOWER PAN HEATER 3 15 15 A .. 480 • .0 480 480 o0 (RANK . 15 EXHAUST FAN EF -1 15 HP THEF t■ c• 120 d" 120 120 2 Ce < N N N (NI N O O SPARE 3,4 3,4 REMOTE START STOP RED PILOT SPARE SIZE 1 - AHRD3 5 40 F THEF ,4 - - SEE E520 FOR CONTROLS LOCATION AHRD2 40 THEF - - SEE E520 FOR CONTROLS LOCATION . gt-1 - . _ 5 - ? J - ? „ AL, a , AtA9LE T T/S OP R PALO „ ,. ,. l - ► 21 0 EF -7 EXHAUST FAN '•1 .1 3 - _ 480 .` ;S 15 THEF 3,4 3,4 REMOTE START STOP, RED PILOT E -g EFRE2 B4 EXHAUST FAN 15 480 3 40 3 THEF - - -- - - - SERVES VFD MOUNTED ADJACENT TO MCC 45. r Pr) r7 M M 1' K? rh •- r- � N 10 I 120 120 72` " 120 CI IX CC F + I+H 1 1 r�i 03 OD 1 SEE E520 FOR CONTROLS LOCATION E -1 EF -11 $5 136 X US F EXHAUST FAN I 3 3 14, H THEF ,4 3,4 LOCAL HOA, RED PILOT 15 EF -12 `tFv4 ~ AHRB2 ... C1 2 C3 EXHAUST FAN NHAtfSl F--N .r v v vv v AIR HANDLER _ ., 3 1" 15 15 THEF '' I 1,4 t, - LOCAL HOA, RED PILOT L AR OP, R IL I , 1 5 40 THEF SEE E520 FOR CONTROLS LOCATION I XFMR G5 CONTROL TRANSFORMER , ' 3 KVA, 484 -12�I' TRANSFORMER I 1 � 1 A B C C D E EXHAUST FAN EF -12 3 HP F BLANK 2 BOOSTED. PU3G3A 2HP PUMP PARE SIZE 1 1 1 COOL WATER PUMP P -8 SPARE SIZE 1 1 SPARE SIZE 1 7.5 HP w SUPPLY FAN AH -2 15 HP 2 4 EXHAUST FAN EFRE2 15 HP 2 COOLING TOWER FAN F- 1 SPARE SIZE 1 2 2 HYDRAULIC AREA SUPPLY FAN AH -3 SPARE SIZE 1 2 SPARE SIZE 1 2 EXHAUST FAN EF -3 1/2 HP 2 3 COOLING TOWER FAN F -2 SPARE SIZE 1 3 3 EXHAUST FAN EF-5 SUPPLY FAN AH -1 20 HP 3 SPARE SIZE 1 3 MCC -2 3 4 COOLING TOWER FAN F -3 BLANK 4 4 (6) 15A, 1P BREAKERS BLANK 4 (RANK . 5 EXHAUST FAN EF -1 15 HP 4 5 COOLING TOWER FAN F - 4 -- 5 COMMON CONTROL TRANSFORMER SPARE SIZE 1 • 4 SPARE 5 5 CONDENSATE PUMP P -10 (2) 5 HP 6 COOLING TOWER PUMP CT -2 SPARE SIZE 1 6 A B C BLANK 1 COOLING TOWER PAN HEATER © COL. F/3.2 EXHAUST FAN EF -12 3 HP 1 UNIT HEATER UH -1 3 HP 2 2 EXHAUST FAN EF -7 3HP EXHAUST FAN F - • HP 2 UNIT HEATER UH -2 HP 3 3 EXHAU FAN EF -: HP AI HANDLER AHRB2 15 HP 3 . . 1 AIR HANDLER AHRD3 15 HP 4 Ems.. 4 EXHAUST FAN EFRE2 15 HP 15A, 1P B' • ERS I AIR HANDLER AHRD2 15 HP 5 5 . HA . F • E - 10 HP COMMON CONTROL TRANSFORMER . . 5 • IT • . • TE' UH -5 3HP 6 6 HAUST FAN EF -11 3HP - . . BUILDING 9.9.9 ELECTRICAL MASTER ca. 534907 -03 - 9-99-E519 453490 ► -C3 C. • M C i .12.GS MANUFACTURER: GE 7700 LINE CONTROL CENTER • MCC -1 MCC -1 SCHEDULE • FURNISH AND INSTALL CONTROL CUT -OFF TOGGLE SWITCHES ADJACENT TO TERMINAL STRIPS IN EACH COMBINATION STARTER COMPARTMENT AS SHOWN ON THE CONTROL DIAGRAMS. TOGGLE SWITCH SHALL BE CUTLER - HAMMER #8280K16 OR EQUAL FOR SPST AND #8360K7 OR EQUAL FOR DPST. I > • MANUFACTURER: GE 7700 LINE CONTROL CENTER 600A MAIN, 480 VOLTS, 120 VOLTS CONTROL VOLTAGE YEAR: 7/5/68; ORDER NO. 77307 MCC -2 • MCC -2 SCHEDULE REFERENCE DRAWINGS: ri> 9- 99 -E520 CONSTRUCTION NOTES: REMOVE EXISTING STARTER BUCKET. PROVIDE A NEW NEMA GENERAL ELECTRIC SIZE 2 STARTER THAT IS COMPATIBLE WITH THE EXISTING MOTOR CONTROL CENTER. REMOVE EXISTING STARTER BUCKET. PROVIDE A NEW GENERAL ELECTRIC CIRCUIT BREAKER BUCKET TO FEED EXHAUST FAN VFD. MOUNT VFD ADJACENT MCC. • 1)‘•* 1 y r PAM: i CE. ♦ TER • • • NNW n V .. • 3o I FIRE ALARM S UT DOWN CONTAC STOP } a 1 Q I START I 0 REMOTE START /STOP IN SECURED AREA 1ST FLR. COL. A--8/3 M •--- ----nom a --: c 0 F R -4 UH - R4c XIX rHu -z EF -8 0 4114 -2 START /STOP PUSHBUTTON STATION W/ RED PILOT LIGHT LOCATED AT COLUMN D/2 JTES: 120V CONTROL (MCC 2) WAND i lk AUTO OFF Q* 'I AUTO 01 0* OFF / AUTO I OFF HAND k / 4 AUTO I C1K --� � II cuts F > UNIT HEATERS AND EXHAUST FANS WIRING DAGRAV CONTROL CUT-OFF SWITCH (TYP) OL'S OL'S - - NOTE 2 - - 1 OL'S V, 1 OL'S OL'S OL'S TYP) A. SM:iCH MOTOR AT AT MOTOR N.O SW` T CH STAR T �R- T1(PiCA! ' ELECTRICALLY C E C!E E ERS =ZD S�._ � L �1 _�� . 2. VIRVeLE FREQUENCY CAVE (VF1) LOCATED Al\AC EN'T TO MCC 2. F.: RV•S!. C EY ME HAMA. CONTRAC CONTRA TOR !PVC INFALLEE BY E! ECTWAL CONTRA TOR . REFER TO Va?& FACTURER'S !NS74',. C OBIS FC iNSTA LA-90 i ANC N- .. t ED PNEUMAT■C SOLE NOi D - NOR MALLY CLOSED WitTli DAM 0 ER CLOSED. W'' ri THE . S. OLENtDI` OPENS AD.: ALLOWS AR c`OW T3 OPEN CAMPERS. DA.M°E APE LC(A . _ ON UNT CONSTRUCTON NOTES: to- Pijo- DISCONNECT AND REMOVE CONTROL DEVICES FROM CONTROL STATION AT COLD /2. FILL DEVICE OPENINGS WITH BLANK FILLER PLATES. LEAVE CONDUCTORS BETWEEN CONTROL STATION AND MCC FOR FUTURE USE. PROVIDE NEW MOTOR STARTER WITH CONTROL WIRING AS SHOWN. VERIFY LOCATION OF ALL CONTROL CUT -OFF SWITCHES IN THE CONTROL CIRCUITS AND MARK ON AS -BUILT DRAWING SET. REFERENCE DRAWING I 1 > 9- 99 —E519 GENERAL NOTES - C It • r - • • C. c% ER amnia 01.12.05 01.12.05 ioLE 01.1/05 ROOF LEVEL PARTIAL STRUCTURAL BUILDING 9-99 A--c 4-1 RFS10 JO. o11. 534907 -03 le C6x8.2x8' -0' 4 PLACES BELOW UNIT SEE D /S500 I I AHRB2, SEE MECH EXISTING ROOF FRAMING, lYP 0 FIELD VERIFY X X X X X x X x X X x x H T R 77 COORD W/ MECH 4 F M � i l i E 160: Filh /berere Sum Sect",, 11/1sh ngtvn 9810T-1 2% 623 0717 For 2t)6 624 3 frt Dsft•o30 I c_ R �\ K PLAN scA-i1U€ • i A iSSX P3R POINVOID INF1LL EXIST OPENING 6'- 6 "x7' -8 W/ 1X 18 GAGE TYPE B ROOF DECK ATTACHED TO SUPPORTS W/ 5 —112 TEK SCREWS IN BOTTOM FLUTES AND 5 —110 TEK SCREWS ALONG SIDE LAPS OF EACH 30" WIDE PANEL AHRD3, SEE MECH C6x8.2x8' —O 4 ' LACES BELOW IT SEE D /S500 COORD W MECH FIELD VERIFY 0 �t _12.06 i I. EFRE2, SEE ME WIN • / EXISTING ROOF FRAMING, TYP VERIFY C6x8.2x8' —O" 2 PLACES BELOW UNIT SEE DETAILS D /S500 COORD W/ MECH x AM/LWOW • x COORD WI MECH x x C6x8.2x8' -0 BELOW UN SEE D /S500 FIELD VERIFY AHRD2, SEE MECH INFlLL EXIST OPENING G 8 7YPE� r 18 ROO ATTACHED TO SUPPORTS W/ 5 —112 TEK SCREWS IN BOTTOM FLUTES AND 5 —110 TEK SCREWS ALONG SIDE LAPS OF EACH 30' WIDE PANEL x 00 x �1 ) 16C1 RP' but sole 90C S sebe. Washington 9e i - Z 6r 236 623 0''' Fa: 2(76 624 3:",! STRUCTURNL IMSTER (F BUIWING 9-99 (ti'mP o t I 4 i ROOF LEVEL PARTW4. STRUCTURAL =ry ,� ,.., PER4;.: ;, ti'c;; • Ca. c -E/4 -1 WV. cOM. IIIA • • OM WM I `Y PJN wow loom roam 534907-.03 RFSII JO. Pe. 534907 -03 9- 99 -ilFSI 1 01.12_w 0 COMP NM I i 4 L3x3x 1/4 FRAME COORD OPENING LOCATION W/ MECH L3x3 FRAME PLAN NEW OPENING SECTION NOTE: SEE MECH FOR LOCATION. ROOF OPENING FRAMING 6C) 3/4 " I ,- 0 " I SEE NOTE 1 GREATER THAN: 3 K SERIES RIES 6" LH SERIES - - r: — I " = I . - 0' rs sr: �r — aramirawr- - — "I 1 xl 1/2x3/16 J; EA . DE � 3/16 3/16 NOTES: 1. WHERE POINT LOADS ARE SUPPORTED BY JOIST CHORDS AND ARE LOCATED MORE THAN 6" FOR LH SERIES JOIST. REINFORCE THE JOIST WITH AN ANGLE EXTENDING FROM THE POINT LOAD TO THE NEAREST PANEL POINT ON THE OPPOSITE CHORD. 2. DO NOT CUT OR DRILL THRU ANY JOIST MEMBER. 3. DO NOT LOAD JOIST PRIOR TO WELDING ANGLE POINT LOAD REINF c EXIST STEEL JOIST STEEL BM 0 SIM M"l 0 0 LOCATE FRAME AT TOP CHORD PANEL POINT OR PROVIDE VERT SUPPORT BTWN TOP & BOT CHORD. NEW DECKING EXIST DECKING EXIST STEEL JOIST RFSIO S500 RFSi T�� NM it CL PANEL POINT RFSIO S500 REST TYP .> NEW DECKING SHIM AS REQD COPE AS READ 3/16 . ROOF OPENING DETAILS � I I /2 "= I'- 0" RFSIO S500 RFSIT+"� "UNIT" 3/ 1 6 V 1 /2 "CURB" 3/16 3/1 s MECH UNIT SUPPORT ' �-- BRIDGING iI 4 ATTACH UNIT TO CURB WI (5) X12 SELF TAPPING . SCREWS ALONG EACH SIDE (2) #12 AT EACH CHANNEL X12 SELFTAPPING SCREWS � 10" ALONG END CHANNELS EXIST OR NEW 1 1/2" DEEP x18 GA ROOF DECK TOP CHORD OF EXIST JOIST NOTES: . 1. REMOVAL AND "REROOFING" AS REQUIRED FOR THIS WORK SHALL BE PROVIDED BY "PUGET SOUND ROOFING" D RFSIOIS500 EXIST STEEL JST TOP CHORD S GENERAL NOTES 1. ALL CONSTRUCTION MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND REGULATIONS OF THE INTERNATIONAL BUILDING CODE, 2003 EDITION. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. BOEING SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES. 3. IF ANY ERRORS OR OMISSIONS APPEAR IN THESE DRAWINGS, SPECIFICATIONS, OR OTHER DOCUMENTS; THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER AND BOEING IN WRITING OF SUCH OMISSION OR ERROR BEFORE PROCEEDING WITH THE WORK. 4. MANUFACTURED MATERIALS SHALL BE APPROVED BY THE CHECKING AGENCY PRIOR TO THEIR USE. ALL REQUIREMENTS OF THOSE APPROVALS SHALL BE FOLLOWED. 5. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. 6. SPECIFICATIONS, CODES, AND STANDARDS NOTED IN THE CONTRACT DOCUMENTS SHALL BE OF THE LATEST APPROVED ISSUE, INCLUDING SUPPLEMENTS, UNLESS OTHERWISE NOTED. MATERIAL SPECIFICATIONS ARE ASTM LATEST EDITION. 7. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. DESIGN CRITERIA ROOF SNOW LOAD: 25 PSF BASIC WIND DESIGN BASIC WIND SPEED: 80 MPH EXPOSURE: C IMPORTANCE FACTOR: 1.0 SEISMIC DESIGN ZONE = 3 IMPORTANCE FACTOR = 1.0 STEEL DECKING 1 STEEL DECK SHALL BE OF THE MINIMUM SIZE, TYPE AND GAUGE SPECIFIED ON THE STRUCTURAL DRAWINGS. STEEL DECK SHALL HAVE CAPACITY TO SUPPORT THE SUPERIMPOSED LOADS AS DEFINED IN THE DESIGN CRITERIA. ALL PROPERTIES AND CAPACITIES SHALL BE VERIFIED BY AN INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS (ICBO) REPORT. 2. MINIMUM BEARING ON SUPPORTS SHALL BE 2 INCHES. 3. DECK AND ALL ACCESSORIES SHALL CONFORM TO ASTM A -653 SS MINIMUM AND SHALL HAVE A MINIMUM YIELD STRENGTH OF 33,000 PSI. 4. DECK SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A -653 OR A -525, CLASS G60. 5. DECKING SHALL BE ATTACHED TO ALL SUPPORTING STEEL MEMBERS. ATTACHMENTS SHALL BE AS INDICATED ON THE DRAWINGS, AND SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND AWS D1.3 "STRUCTURAL WELDING CODE - SHEET STEEL". • 1601 Fitt !venue Smote SOO Seattle, iiragton 9e101-1625 623 C7' c3c 206 624 3775 STRUCTURAL STEEL, MISC. METAL 1. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL BE BASED ON THE LATEST EDITION AND SUPPLEMENTS OF THE AISC "SPECIFICATION FOR STRUCTURAL STEEL FOR BUILDINGS - ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN ". STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS. TYPE OF MEMBER: ASTM SPECIFICATION, Fy PLATES, SHAPES, ANGLES, AND RODS: A36, 36 KSI, UON CONNECTION BOLTS (3/4 IN DIA UON): A325N,UON 2. THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW BEFORE FABRICATION. 3. ALL WELDS SHALL BE PREQUALIFIED IN CONFORMANCE WITH AISC AND AWS STANDARDS AND SHALL BE PERFORMED BY WELDERS WABO CERTIFIED IN THE JURISDICTION HAVING AUTHORITY OVER THIS PORTION OF THE WORK. USE E70XX ELECTRODES. 4. WELD LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE LENGTH REQUIRED. WELD SIZE SHALL BE AISC MINIMUM, UNLESS OTHERWISE NOTED. SPECIAL INSPECTION 1. SPECIAL INSPECTION BY A REGISTERED DEPUTY BUILDING INSPECTOR, APPROVED BY BOEING AND THE CHECKING AGENCY SHALL BE REQUIRED IN ACCORDANCE WIT'S SECTION 109 AND SECTION 1704 OF THE IBC. 2. SPECIAL INSPECTIONS SHALL NOT BE REQUIRED WHEN THE WORK IS DONE ON THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED BY THE BUILDING OFFICIAL TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. 3. NONDESTRUCTIVE INSPECTION OF ALL WELDS, SHOP AND FIELD, OF THE MOMENT - RESISTING FRAMES SHALL BE PROVIDED IN ACCORDANCE WITH THE GOVERNING CODE. 4. THE STRUCTURAL ENGINEER, BOEING, AND THE BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL TEST RESULTS. C` • 1),5%•tp.3 _r- ?J.' .. -. 1 v i• z