Loading...
HomeMy WebLinkAboutPermit M05-031 - WASHINGTON STATE SCHOOL RISK MANAGEMENT POOLWA STATE SCHOOL RISK MANAGEMENT POOL 320 ANDOVER PK E EXPIRED O1 -11 -06 M05 -031 rt 0O Nom! W W N u- W O' !L Q, 2 V 0, ;o� ,o1-. WW ILI Parcel No.: Address: Suite No: 0223200060 320 ANDOVER PK E TUKW Tenant: Name: WASHINGTON STATE SCHOOL RISK MANAGEMENT POOL Address: 320 ANDOVER PK E, TUKWILA WA Owner: Name: CENTERPLEX Address: 331 ANDOVER PARK EAST #100, TUKWILA WA Contact Person: Name: ERNANI NARAG Address: 3132 NE 133RD ST, SEATTLE WA Contractor: Name: PUGET SOUND REFRIGERATION INC Address: PO BOX 27073, LAKE CITY STATION Contractor License No: PUGETSR169CB DESCRIPTION OF WORK: MOVING THREE (3) THERMOSTATS, INSTALLING TWO (2) NEW EXHAUST FANS, INSTALLING NINE (9) NEW RETURN AIR GRILLES AND NINETEEN (19) NEW DIFFUSERS. Value of Mechanical: $10,000.00 Type of Fire Protection: SPRINKLER doc: IMC- Permit City a Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 2 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -031 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 367 -2500 Phone: 206 367 -2500 Expiration Date :12/31/2006 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -031 03/21/2005 09/17/2005 Fees Collected: $269.58 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 19 Thermostat 3 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment... 0 Printed: 03 -21 -2005 Signature: Print Name : � , � u ' doc: IMC- Permit City o Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us M05 -031 Steven M Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -031 Issue Date: 03/21/2005 Permit Expires On: 09/17/2005 Permit Center Authorized Signature: Date: C.Ia... /q ( / I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construe n oy- rformance of work. I am authorized to sign and obtain this mechanical permit. Date: ° This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 03 -21 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223200060 Permit Number: M05 -031 Address: 320 ANDOVER PK E TUKW Status: ISSUED Suite No: Applied Date: 03/11/2005 Tenant: WASHINGTON STATE SCHOOL RISK MANAGEMENT POOL Issue Date: 03/21/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M05-031 Printed: 03 -21 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. Print Name: f/. ► AA! doc: Conditions M05 -031 Date: 3 -'Z (-°S-- of law and ordinances other work or local laws Printed: 03 -21 -2005 SITE LOCATION King Co Assessor's Tax No.: 02 -?Do 60 61 LS, Y6 Site Address: 3.7 Ak!%oV#/Z PARK EAST "TUkLQW4 144 • Suite Number: 2so, 27.5 Floor: .2he1 Tenant Name: WAs • NIUGioP 31TE .Sat4COL- amp: N1A1 'POOL New Tenant: ❑ Yes ..No Property Owners Name: Oh ctt - IWS 14.61(P /1/ AurotDRITV ?SI er Mailing Address: 3 20 4NNve/ P t —T ••f-"t,tkwt4.4%. City CONTACT PERSON Name: £RN44.11. Nbt & Mailing Address: 3 i 3q N •C . l33 •T • E -Mail Address: CLr t • p.sre..'• Gor+'' Company Name: PUGST Mailing Address: Contact Person: EP4Atvl MP4AG• E -Mail Address: \applications \permit application (7.2004) CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 W TUKWIL A w Building Permit No Mechanical Permit No. Public Works Permit No. Project No. (For oJrce use only Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SoG•J U p6'FIZ 4.9 °ATr o N 3 132 N • E /3J 5T . Pace 1 State Day Telephone: . 206 ' - 36 ' 7 –2 50 0 Zip .»rrt.E WA . 4li'r2S City State Zip Fax Number: 28ro- 3to Gg,s& GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) rtts City Day Telephone: W A• E -Mail Address: v-rn arts • Aar ag psref` con') Fax Number: 2C6. - ,3G 1s CP 'SCo State 9e r.'S State Zip 200 - ,30 7 - 25 Contractor Registration Number: PaGETS / Gil G (3 Expiration Date: L2-3/- OG * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip Contact Person: City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: S ta t e Zip Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser I ct 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 2 Thermostat .3 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION — 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: PI-16T SOIIND jQ6 Mailing Address: 31aa NE /35 3"r' SrM1G� Wa q-,- City State Zip Contact Person: rFNAN t NA.Rt G Day Telephone: 4OC. - 2 Sin E -Mail Address: ✓ tt - het rut e psr to f COIsI Fax Number: 2c& - 6&5' Contractor Registration Number: P1 .E -5R I& CE'1 Expiration Date: 42- 31 - o le * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 10,000 Scope of Work (please provide detailed information): Move' 3 ,me—r MDc -rm , I XI' 1h L LB EXNausT FAn), lu srAt•t 9 N L`vd 1C. - /log G�tw , a►a° 191?rust s- g N i q N 4-tA ) Use: Residential: New ❑ Replacement ❑ Commercial: New © Replacement Er Fuel Type: Electric ❑ Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to all permits in this application i Value of Construction — all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO API'LY FOR THIS PERMIT. BUILDING OWN . ' OR RIZED AGENT: Signatur Print Name: FgIJA. I I # 6, Mailing Address; 313 S. 1 33 s = I Date Application Accepted: \applications \permit application (7.2004) Pace 4 Day Telephone: SrA r1,E City Date: -3 /i I / 05 a ay-3( r- a S00 WA - State Staff Initials: Date Application Expires: i Receipt No.: R05 -00366 Initials: SKS User ID: 1165 Payee: PUGET SOUND REFRIGERATION ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payment Check 10143 MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Parcel No.: 0223200060 Permit Number: M05 -031 Address: 320 ANDOVER PK E TUKW Status: PENDING Suite No: Applied Date: 03/11/2005 Applicant: WASHINGTON STATE SCHOOL RISK MANAGEMENT POOL Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Amount: 269.58 Payment Date: 03/11/2005 02:43 PM Balance: $0.00 269.58 Account Code Current Pmts 000/322.100 221.66 000/345.830 47.92 Total: 269.58 0057 03/14 9710 TOTAL 269.58 Printed: 03 -11 -2005 12 -05 -2005 ERNANI NARAG 3132 NE 133RD ST SEATTLE WA 98125 RE: Permit No. M05 -031 320 ANDOVER PK E TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 01/11/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, n hi � 1A Ot�1 U Permit Technician J xc: Permit File No. M05 -031 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M05 -031 DATE: 03 -11 -05 PROJECT NAME: Washington State School Risk Management Pool SITE ADDRESS: 320 ANDOVER PARK EAST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision #_after /before permit is issued DEPARTM NTS: i Bui ivision • Fire vent on J Planning Division Public Works ❑ Complete (R( Incomplete ❑ REVIEWER'S INITIALS: Documents /routing slip.doc 2-28-02 Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03 -15 -05 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route [i! Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 04 -12 -05 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) El Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY EL t'T Z I 8 6, VM TILLVaS NOIIVIS LLI ELOLZ xog 0.d DNI NOLIVEHOTdaal aNnossond • Tpgaig.a 0§- � 1/4-v-L , qVHaNSO MOD ,ISNOD SV MVI AR aaa'Aolla SV ammIsiosu S1RILSf1CINI (INV 110i1V1 dO - - NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR - THAN _ THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. _ _ _ . Q6/VOWZO-g9di I EXHAUST FAN SCHEDULE UNIT * MANUFACTURER MODEL * TYPE TOTAL CFM RPM ESP HP/BHP ELECTRICAL DATA WEIGHT REMARKS VOLTAGE PHASE MCA MOCP EF -1 BROAN L200 CEILING 200 120 1 1.8 N/A 23 LBS CONTROLLED BY THERMOSTAT EF -2 BRQAN X200 CEILING 200 120 1 1.8 NiA 23 LBS CONTROLLED BY LIGHT SIMTCH • 6 I ' • L S 144th St 1,..99 -.. 4 146th SI 14&h St — .—w ; . ok S 156th St - -_1... w VM I • I 1 ca. S ifeith 9 5 _ ▪ -�. VV�.�Yk�TSt rr77ll S172nd -__ • ---S-1750;- St SeaTac . - . S•176th St =..� -- y . L -5 .2 St Date �C ' • ; ' 52 x@2004 Microsoft snip 02003 Nati'Tech . andfor GaT, Inc . Mk b 4B 152nd St • • • p it,•• „. Trileted Dr s • - c 2 VICINITY /SITE MAP ADDRESS: 320 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 OWNER: WCIA PARCEL: 0223200060 LEGAL: 6ANDOVER INDUSTRIAL PARK #3LESS N 185 FTLESS UP RR OPERR/W FILE aovr PsnnItNo./YO 0,1 errors and omissions. Ap � p�io�d mi�strWbn dm � its does not authorize the NWetim of aM adopted aade or ordinance. Receipt d approved P and conditions k adaiowledpedc J IwmG DIVISION ort Beni 3 Boeing w 16th St .....,.... i _ . , _ Lyres Ins 320 Andover Park E Seattle WA, 98188: 10 i(� ; , -s!w 7 St . _.... ..4 - 9th . -St • r_:. Renton a., 27th ___1 - 34#1 s 2 . 911/49th „ t $W -4 -1st- S Orillie 1 -0 " 9$ 12p ... I r I W 0 D Z 1 Q W cc a SEPARATE vEaat n FOR: 0 Mechanical oecb+a it rig oie Gas pwng city Of Tukwia BUILDING DIVISION L�J N ►I 0 LEGEND EXISTING DIFFUSER N NEW DIFFUSER EXISTING RETURN GRILLE N NEW RETURN GRILLE NEW EXHAUST FAN RELOCATION ARROW THERMOSTAT 0 10 20 40 1" 40' t = AREA OF WORK - SECOND FLOOR I _ GENERAL NOTES 1) DUCTWORK TO BE SHEET METAL CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS. 2) FLEX DUCT MAY BE USED ON BRANCH DUCTS WHERE ENTIRE LENGTH OF FLEX IS ACCESSIBLE FROM BELOW. MAXIMUM LENGTH OF FLEX DUCT TO BE EIGHT FEET. 3) PROVIDE A VOLUME DAMPER ON THE BRANCH DUCT SERVING ALL SUPPLY REGISTERS AND DIFFUSERS. 4) COORDINATE EXACT LOCATIONS OF ALL THERMOSTATS. 5) COORDINATE EXACT LOCATIONS OF ALL GRILLED, REGISTERS, AND DIFFUSERS WITH REFLECTED CEILING PLAN. 6) NEW DUCTWORK TO BE SEALED IN ACCORDANCE WITH ENERGY CODE SECTION 1414. 7) THERMOSTATS TO BE CONNECTED TO BUILDING CONTROL SYSTEM TO BE 7 DAY PROGRAMMABLE WITH 5 DEGREE DEAD BAND. 8) NEW DUCTWORK SHALL BE INSULATED IN ACCORDANCE WITH ENERGY CODE SECTION 1414.2. 9) NEW DUCTWORK SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH SMACNA GUIDELINES AND LOCAL REQUIREMENTS. 10) SUPPLY AIR TEMPERATURE RESET CONTROLS ARE INCLUDED PER ENERGY CODE SECTION 1432.2.1. 11) SIMULTANEOUS HEATING AND COOLING WILL NOT OCCUR EXCEPT AS ALLOWED BY ENERGY CODE SECTION 1435. • f = • Z3G r r 11O.,f • General Notes No Revision/Issue 1 Dated J 0 0 i-- z w (9 0 < aU Ce � >O ±O LL O 0 F- W H co co c og CC ° c.9 00 Z CC a) o < 'S 0 Za Q J (J1 I- EN 9. 3 t, 1 0F2] J • - _ ,... ." • .• yggp • • LEGEND �r?� II L =J EXISTING DIFFUSER )::( N NEW DIFFUSER 2_7, EXISTING RETURN GRILLE NJ N NEW RETURN GRILLE NEW EXHAUST FAN ,`"'--- RELOCATION ARROW 0 THERMOSTAT .• s it `E I! i �� I;; AREA = 1�'5�SF. AREA = S4. S.F — --- : - r- 8 3/32 " =1 '0" 12" X 12" SOFFIT GRILL QN BY T- V, I 4 ;IItE1111 i 14-� iiUUi■��t r � •:!w►fui f� r, au r. i■iw�iri Sri r 1ls1• Iiu1��4. f • - r -- �� ,�►�� � • ;:.. ���■■r��rr� :• � R,:: -- � ME IMP r� -� w�r�n ��::.:. Ima iiii�•• - a._ • ■• ' PROVID INSTALL ?fa YPSR BY EC Il�li ,ssimaroo,a ►eunw • ma p ltstaillIkg. i =: r ^ •.-�rr.il_._ \. r�i�i ¶. \ ■ .• r- �. a •-u - -w. •• --r.. -- SECOND FLOOR HVAC PLAN - 8"0 tt C OT: fi r- - ` • ctc . p , '`!A S -)0,) RECEIVED CITY OF rukbvtA • ' . PERINI rt.: : NO " ' eneral Notes Revision/Issue Date J Oz 1- a- Z U 2Q f-- 5 O� (f) w O o —109 Z U.a U 0 PI In Z � O <LU U) Ci) 5 EN 3-9-05 "•r\a,a 1\r•. C Th - F ?: �*T3 Swam l4o..7a - "c co Co 0, z 0 z Q -"§". I- � OF2J J • I •■••,: •i.v. • �1 - fr ...... •116 i •