Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M05-034 - MIYABI RESTAURANT
MIYABI RESTAURANT 16820 SOUTHCENTER PY .EXPIRED 07-25-06 M05-034 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: City c,i Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Parcel No.: 2623049129 Address: 16820 SOUTHCENTER PY TUKW Suite No: MIYABI RESTAURANT 16820 SOUTHCENTER PY, TUKWILA WA PARKWAY SQUARE C/O ROSEN PROPERTIES, PO BOX 5003 CANDICE GALLAGHER Address: 2800 THORNDYKE AV W, SEATTLE WA Contractor: Name: WASHINGTON ENERGY SERVICES CO Address: 2800 THORNDYKE AVE W, SEATTLE, WA Contractor License No: WASHIES9710B DESCRIPTION OF WORK: GAS TO GAS WATER HEATER HANGE OUT - MODEL RHEEM G91 -200. Value of Mechanical: $1,000.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC- Permit MECHANICAL PERMIT M05 -034 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 282 -4700 Phone: 206 282 -4200 Expiration Date:09 /02/2005 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -034 03/24/2005 09/20/2005 Fees Collected: $170.40 International Mechanical Code Edition: 2003 EQUIPMENT TYPE AND QUANTITY * *continued on next page ** Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 1 Emergency Generator 0 Other Mechanical Equipment Printed: 03 -24 -2005 Permit Center Authorized Signature: doc: IMC- Permit City o Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us 1 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -034 Issue Date: 03/24/2005 Permit Expires On: 09/20/2005 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to gi uthority to violate or cancel the provisions of any other state or local laws regulating constr ion the perform nce o w I authorized to sign and obtain this mechanical permit. Signature; -titer /, Date: 3- 7 / 2 Print Name: �1 �h� -� ' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M05 -034 Printed: 03 -24 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049129 Permit Number: M05 -034 Address: 16820 SOUTHCENTER PY TUKW Status: ISSUED Suite No: Applied Date: 03/16/2005 Tenant: MIYABI RESTAURANT Issue Date: 03/24/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M05 -034 Printed: 03 -24 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. Signature: If ..da/� r i . /4:4 Print Name: j��G � /I�z� � doc: Conditions M05 -034 of law and ordinances other work or local laws Date: Printed: 03 -24 -2005 ti Mailing Address: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: Z(X/5 0+,1 Site Address: / 1.p 2-0 A- _ l Suite Number: Floor: S New Tenant: Ei .... Yes 0 ..No Property Owners Name: :CO NTACT PERSI Name: (14 — r p.'lvv / IZZ.0 Lpt GENERAL . CONTRACTORINFORMATIO Company Name: W s!1 $22,C G t :1--e.iUl Mailing Address: f[ Contact Person: CAW (CQ-- 6ailayter E -Mail Address: Expiration Date: 4 /2,/t -?) * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Contractor Registration Number:WP Y✓/ / Z5 q7 ( )t II plans must': 4f'stamped'by ArchitectofRecord Company Name: Mailing Address: Contact Pers E -M . • Address: ENGINEER OF RECORD — All plans must be wet stamped by Engineer= oi:Itecord Company Name: Mailing Address: Contact P - on: E- • Address: \applications\permit application (3.2003) 3/2003 Page 1 City City Fax Number: (--UCP R3 State eirrn-(-U) Day Telephone: "7 3 2? State City Day Telephone 6 2- t r / Fax Number: City State City Day Telephone: Fax Number: State Zip Zip Zip Zip Zip Day Telephone: Fax Number: Jug• R.: r�3q{ dia'(pi:l::,ny.all:P�.v1.'.c'Fi e.l .ray- .i y:, l «�.L'�:: I . BUILDING ..PERMIT:INFORMATION. = :206-431 -367.0 :Y,'.� ye •L•�...S�X: :..' ?'%1; ?,. . . .. �..�'�' .. Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes ❑ .. No rovide All Building Areasin Sguare Footage :Below ' 2 "?,Floor.: 3 °:Floor.:; ..Floors" "B Accessory Structure *; -Attached. Garage Detached.Garage:'_ Attached 'Carport Detached ; Carpa CoveredDeck :: : Uncovered Dec Interior Remodel Addition;to `: :Ezistmg ` Structure: " • Construction Type. of Occupancy per UBC' `. . PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑ ..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. ta.ppliatiomtpermit application (3.2003) 3/2003 Page 2 Existing Building Valuation: $ If "yes ", see Handout No. for requirements. Handicap: • C WORKS 'PERMIT INFORMATION: :206-433 =017 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila 0... Water District #125 ❑...Water Availability Provided Sewer District ❑ ...Tukwila ❑... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑...Total Fill ❑...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑ ... Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public _ tappllcatiotutpertnit application (3.2003) 3/2003 Please refer t� .Public Works Bulletin #1 for_fees:and estimate-sheet. cubic yards cubic yards „ Call before you Dig: 1-800-424-5555 ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line WO# W O# W O# Private Private ❑ .. Highline ❑ ...Renton ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size " FINANCE INFORMATION Fire Line Size at Property Line ❑... Water ❑...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip Page 3 Unit Type: ` Qty : :Unit:. Type: • Qty _' ;Unit Type: : Qty , :Boiler /Compressor:.:.. Qty . . Furnace<100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Fumace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System t (�(� ` / r 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind MECHANICAL. P,ERMITsINFORMATION :4 MECHANICAL CONTRACTOR I FORN Name: �V) Company CLJ Mailing Address: Contact Person: G -MLce_ E -Mail Address: Contractor Registration Number: W 1 - f ( ) J " ? / 6 B Expiration Date: 9(2_ /c) * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ C / �� ' Scope of Work (please provide detailed information): qa.T W t_ 12/5-4e lh094).el 70ee M 240 Use: Residential: New ....El Replacement .... Commercial: New .... Replacement _XI Fuel Type: Electric fJ Gas.... Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R OR AUT IZED AGENT: Signature: Print Name: L-i al / �, / Day Telephone: Mailing Address: g())( 2453 `/ 3 1 1t t k—kuc) \applications\permit application (3.2003) imn^+ Nor 4 City Stale Zip Day Telephone: CO 2 2-q2 Fax Number: City Date: ` / 6e 7 c C/1577032 8' State Zip Date Application Accepted: 1 Date Application Expires: l Staf hrlt' Is: i -- "/& — 0c5 7 I 9 —O" City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049129 Permit Number: M05 -034 Address: 16820 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 03/16/2005 Applicant: MIYABI RESTAURANT Issue Date: Receipt No.: R05 -00415 Payment Amount: 142.32 1 Initials: SKS Payment Date: 03/24/2005 02:41 PM User ID: 1165 Balance: $0.00 Payee: WASHINGTON ENERGY SERVICES TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description doc: Receipt RECEIPT Amount Payment Check 4559 142.32 MECHANICAL - NONRES Account Code Current Pmts 000/322.100 142.32 Total: 142.32 1394 03/24 9716 TOTAL 284.64 Printed: 03 -24 -2005 U) w 9 o ID 2 g J. u, 3. F Z H, j Z O, } ' ? 0 0I- ID Z F- = i 0 • Z Parcel No.: Address: Suite No: Applicant: Receipt No.: R05 -00379 Initials: BLH User ID: ADMIN Payee: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 16820 SOUTHCENTER PY TUKW MIYABI RESTAURANT WASHINGTON ENERGY SERVICES COMPANY TRANSACTION LIST: Type Method Description Payment Check 4526 PLAN CHECK - NONRES Account Code 000/345.830 RECEIPT Permit Number: Status: Applied Date: Issue Date: Payment Amount: 28.08 Payment Date: Balance: Amount 28.08 Current Pmts 28.08 Total: 28.08 M05 -034 PENDING 03/16/2005 03/16/2005 01:27 PM $142.32 1070 02/16 9710 TOTAL 56.16 Printed: 03 -16 -2005 Project: Alt/ ; .4 'Type of Inspection: /ea) ..41./.. 4 / Addrez f �ate Called: Special Instructions: , . . , Dat anted: C /-2—, P.m. Requester: Phone No: 2f:?;--93/- 2e-'2:2 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 Approved per applicai:1 c r COM E ector. • INSPECTION RECORD Retain a copy with permit I j . PERM (206)431-367 Corrections required prior to approval. -2, 4/„,/ r „ 5 0 /te,d-140 c. -/ - . 10! e, D te: /2 qL ‘e4 El $58.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No:: 'Date: • COMMENTS: Type of Insp en: " Address 1 S;0 - S i • pkixy Date Called: -- Jo/D) ....- Speci1 Instructions: (,O4 '‚4 / 1411-Y 20frO .4111a? Al , f e ____ c-, 2v 93,--, , i , --z., 2-e7 - 6-6.. 3 ‘Pg 7 457 1 to,wu .)--7 e., ,- ..... 'TT / ....... / / l d ... ....",---/ . __--- 7 _.. f& iY1 c4- „-- Pr 1, raAro Type of Insp en: " Address 1 S;0 - S i • pkixy Date Called: -- Jo/D) ....- Speci1 Instructions: (,O4 '‚4 / 1411-Y 20frO .4111a? Date Wanted: i ra.05 a'. . P. • Requester: 1 to,wu P e P e N • al.---7olo INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 11,7 • .t,f" • - ot.p.1■ (2 I Date:67 ,./ 2 -3670 JA Corrections required prior to approval. 'Inspector: EJ $58.00 REINSPECTION EE REQUIRED. Prior to Inspection, fee must be paid at 6300'Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt IDate: File: M05 -0034 re w2')., 00 cop, ..t cnLL W }0}; g J1. z g! W W i01—? W = Vi - UJZ` oil 7 --. • VI's i Gas Comn. :lai water MAR - 3 ZOOS R �"� a G Heaters RUUD • Universal tank design — • Low profile automatic flue maximizes installation adaptability damper — by offering models with Top, Front low profile design minimizes over - Side and Rear Side Inlet/Outlet ail product height. New heavy duty water connections. vent hood supports are designed • Universal space saver design — to withstand rigors of installation. short heights and small jacket • Spark - To-Pilot Ignition system — diameters result in greater standard on all models. Provides installation flexibility. reliable and energy saving ignition • Patented multi flue tank design — sequencing by igniting the pilot proprietary steel formulation, only when the thermostat calls for patented multi -flue design, and heat. two coats of high temperature • System Sentinel° LED porcelain enamel to maximize diagnostic system — corrosion resistance result in a our exclusive diagnostic system, superior heat exchanger design. with glowing LED lights, verifies system operation sequence by sequence. Short RE �uK`N�� • Full port, full flow brass drain Height Floor-to-Vent C A 1 '66 vahie Certifications and Rating Small Jacket Diameters Multiple Water Connection Options Nom REV FOR CODE COMPLIANCE MAR 1 8 2005 / Of BUILDING D ' /TSION Iq/ -z= Construction Features: Available In Sizes Ranging From 35 -100 Gallon Tank -Type Models 98,000 BTU/Hr. thru 400,000 STU/Hr. Universal Gas Commercial Water Heaters are specifically designed to minimize the difficulty of replacing failed water heaters and are versatile for new installations. These products are designed for applications requiring large quantities of hot water. FILE S N • Efficiency — these models have been tested according to ANSI test procedures, and exceed the thermal efficiency and standby . loss requirements of ASHRAE Standard 90.1b-2001 (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). • Safety and construction — these products are design certified by the CSA: a) For operation at 180 °F. b) To meet all safety and construction requirements of ANSI Z21.10.3. c) As an automatic storage or instanta- neous water heater. d) As an automatic circulating tank water heater. e) For operation on combustible floors and in alcove installations. All models are North Carolina Code compliant. CERTIFIED FOR A 150 PSI MAXIMUM WORKING PRESSURE (160 PSI FOR ASME MODELS). • Optional constructions — ASME construction is available on designated models. UL Sanitation (NSF5) compliant models are available when equipped with optional leg kit. (Part No. AE35450) Continued next page. M 05» O) DIMENSIONAL INFORMATION All Dimensions Shot.)n to English and Iletiic WATER CONNECTIONS APPROXIMATE SHIPPING MODEL R UNITS A B C D E , F G H, IN/OUT , FRONT DE REAR ASME G50-98 inches 82 -3/4 57- 118 22.112 22 -5/8 5 50-112 1/2 15 1 1 -1/2 1 -1/2 270 Ibs. N/A rrvn 1594 1451 667 575 127 1283 13 381 25 38 38 122 kgs. WA 675.125 Inches 65-1/2 61 26-1/4 25 5 56 3/4 20 1 -1/2 1-1/2 1 -1/2 480 Ibs. N/A mm 1664 1549 667 635 127 1422 19 508 38 38 38 1-1/2 2174s. 4901bs. WA N/A 082 -156 Inches 68-13/16 64 26-1/4 25 6 58-5/8 3/4 20 1 -1/2 1 -12 mm 1748 1628 667 635 152 1489 19 508 38 38 38 222 kg3. WA G76-180 inches 68. 13/16 64 26-1/4 25 6 58-5/8 3/4 20 1 -1/2 1-1/2 1-1/2 5401bs. N/A mm 1748 1826 667 635 152 1489 19 508 38 38 38 245 kgs. N/A 037 -200 inches 49-1/4 43-3/8 26-1(4 25 6 37-5/8 3/4 20 1 -12 1 -1/2 1-1/2 4051bs. N/A mm 1251 1102 667 635 152 956 19 508 38 38 38 184 kgs. NIA 076-200 Inches 68-13/16 64 26-1/4 25 6 58-5/8 3/4 20 1 -1/2 1-1/2 1 -112 540 Ibs. WA mm 1748 1628 667 635 152 1489 19 506 38 38 38 245 kgs. N/A -" Z inches 76 -5/16 71- 13/16 26.1/4 30-5/8 6 66-3/8 3/4 20 1-1/2 1 -1/2 1 -1/2 600Ibs. N/A m 1938 1824 667 7711 152 1686 19 508 36 38 38 272 kgs. WA 0100- 200(A) inches 73.1116 68-1/8 30-1/4 23 -1/4 8 ' 57.1/2 3/4 23 1 -1/2 2 2 780 lbs. 835 bs. mm 1856 1580 768 591 152 1460 19 584 38 51 51 353 kgs. 370 kgs. 072- 250(A) Inches 71- 1/16 64-1/2 26-1/4 25 6 58-5/8 3/4 20 1 -1/2 1 -1/2 1 -1/2 590 lbs. 630 bs. mm 1805 1836 087 835 152 1459 19 500 38 38 38 287 kgs. 285 kgs 0100- 250(A) Inches 73 -1/4 66-1/8 30-1/4 23-1/4 6 57 -1/2 3/4 23 1 -1/2 2 2 795 bs. 835 Ibs. mm 1861 1880 768 591 152 1480 19 584 38 Si 61 360kgs. 379 kgs 6100-270(A) inches 73-7/8 66-1/8 30-1/4 23-1/4 6" 57- 112 3/4 23 1 -1/2 2 2 805 Ibs. 845 Ibs. mm 1876 1880 768 591 152" 1460 19 584 38 51 51 365 kgs. 383 kg*. G72- 300(A) inches 71 64-1/8 26-1/4 25 8 58-5/8 3/4 20 1 -1/2 1 -1/2 1-1/2 590 lbs. 6301bs. mm 1803 1829 667 635 203 1489 19 508 38 38 38 267 kgs. 285 kgs. G85.300(A) inches 78 -7/16 72 -5/16 26-1/4 30-5/8 8 66-3/8 3/4 20 1 -1/2 1-1/2 1-1/2 640Ibs. 680 lbs. m 1992 1837 867. 773 203 1688 19 506 38 38 38 290 kgs. 306 kgs. G100- 310(A) inches 75 6812 30-1/4 32 -1/4 7 61-3/4 3/4 23 1 -1/2 2 2 770 lbs. 810 Ibs. mm 1905 1740 768 819 178 1568 19 584 38 51 51 349 kgs.. 357 k9s. G65- 360(A) inches 70-11/16 64-12 26-1/4 25 8 58-5/8 3/4 N/A N/A 1 -1/2 1-1/2 640 Ibs. 680 lbs. m 1795 1638 687 835 203 1489 19 WA WA 38 38 290 kgs. 308 1rgs. G65- 400(A) inches 70- 11/16 64-1/2 26-1/4 25 8 58-5/8 3/4 N/A N/A 1-1/2 1-1/2 640 lbs. 680 lbs. mm 1795 1838 667 635 203 1489 19 WA WA 38 38 2901m. 308 kg3. G85- 400(A) inches 78 -13/16 72.5/16 26-1/4 30-5/8 10 66.3/8 3/4 20 1 -112 1-1/2 1-1/2 640 lbs. 68083S. mm 2002 1837 667 778 254 1686 19 508 38 38 38 290 kgs. 308 kgs. G100- 400(A) inches 76 68 -1/2 30-1/4 32 -1/4 8 61.3/4 1' 23 1 -1/2 2 2 770 bs. 810 lbs. mm 1830 1740 788 819 203 1568 25' 584 38 51 51 349 kg& 387 kgs. Universal Gas continued. "3/4" (19mm) for LP. Models. " 7' (178mm) Vent for LP. Model. Increase Height 3.6/8" (92mm) for NSF Models. All Models Require a 120V Power Souncel02 amps. (A) Suffix Indicates ASME Tank Construction Available. RHEEM -RUUD UNIVERSAL" CLEARANCES MODEL HUMBER TO COMBUSTIBLES UNITS SIDE REAR TOP G50 -98 Inches 2 2 12 mm 51 51 305 G75 -125 Inches 2 2 12 mm 51 51 305 _ G82 -156 inches 2 2 12 mm 51 51 305 G76 -180 Inches 2 2 12 mm 51 51 305 G37 -200 Inches 2 2 12 mm 51 51 305 G76 -200 Inches 2 2 12 mm 51 51 306 inches 2 2 12 _ min 51 51 305 G100- 200(A) inches 2 4 12 mm 51 102 305 G72.250(A) inches 6 8 12 mm 152 152 305 G100- 250(A) Inches 2 4 12 mm 51 102 305 G100- 270(A) Inches 2 4 12 mm 51 102 305 G72- 300(A) Inches 6 6 12 mm 152 152 305 085- 300(A) inches 6 6 12 mm 152 152 305 G100-310(A) Inches 6 6 12 mm 152 152 305 G65- 360(A) Inches 6 6 12 mm 152 152 305 065- 400(A) inches 6 6 12 mm 152 152 305 G85 -400(A) inches 6 6 12 mm 152 152 305 G100-400(A) inches 6 6 12 mm 152 152 305 5 Universal Gas continued. DIMENSIONAL DIAGRAM .44■■■ H _- -► OUTLET T TOP E f I 1 / TOP OUTLET REAR SIDE SYSTEM SENTINEL G ati (17omm) CD Dr- S OUTLET T &P FRONT SIDE C --► INLET FRONT SIDE INLET REAR SIDE 0 F B A w RHEE J-RUUD UNIVERSAL Mow a nliollnym.of 11l (457mm) front clears ffe�.se,vIcing 15, 06 -09 -2006 CANDICE GALLAGHER 2800 THORNDYKE AV W SEATTLE WA 98199 RE: Permit No. M05 -034 16820 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Thank you for your cooperation in this matter. Sincerely, xc: rshall, t echnician Permit File No. M05 -034 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/25/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 08 -03 -2005 CANDICE GALLAGHER 2800 THORNDYKE AV W SEATTLE WA 98199 RE: Permit No 16820 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a' final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is: intended determine:if substantial.work has!been accotnplished issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made; the Building Code does allow the Building Official :to approve a one- time•ertension up,to'180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 09/20/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Brenda Holt, Permit Coordinator ititor xc: Permit File No. M05 -034 Bob Benedicto, Building Official City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 ACTIVITY NUMBER: M05 -034 DATE: 3 -16 -05 PROJECT NAME: MIYABI RESTAURANT SITE ADDRESS: 16820 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENT :(' Builds Division icct Public Works DETERMINA N OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 3 -17-05 Complete PERMIT COORD COPY PLAN REVIEW/ ROUTING SLIP Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents /routing sllp.doc 2 -28 -02 Fire Prevention Planning Division Structural ❑ Permit Coordinator IL Incomplete Not Applicable ❑ ❑ No further Review Required ❑ DATE: DUE DATE: 4 -14 -05 Approved ❑ Approved with Conditions © Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Are ❑ Ping ❑ PW ❑ Staff Initials: Title My Appointment Expires on i it 4b 3 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONft GENERAL 1 CCO1 WW HXES971OB 09702/2005 fiFFECTIVE DATE 09/02/2003 WASHINGTON ENERGY SERVICES CO - 2800 THORNDYKE AVE W SEATTLE WA 98199 • Detach Md Ditplao Certificate State of Washington County of Snohomish I certify that this is a true and correct copy of said document as of this date Date: M /03 • 1 • • • ;! 3 I 1 .I re U' N W W 0 2 g J; u. d'. H W Z pi • WW 0. Z U N;. x;. 0. z File: M05 -0034 35mm Drawing #1 r _ LO — N = N = 0 C 0 — 60 11100666• M N qt r t V FEB - 08 -2005 10 :20 c .1 • WASH ENERGY SERVICES • • • • ..._ •_ _ .- - • • - -•.... I . • • • 69 gal 2063786600 P.05/08 ._. __.._...- --------- .... - -- ..._.:_ ..- ...... .• • vre 1 • oir