Value of Mechanical: $30,000.00
Type of Fire Protection:
doc: IMC- Permit
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: ci.tukwila.wa.us
CAREER EDUCATION CORPORATION
655 ANDOVER PK W, TUKWILA WA
LOWE NORTHWEST INVESTOR PRO
600 UNIVERSITY ST, SUITE 2820
JANA HERMANSON -
1221 2 AV N, KENT, WA
Contractor:
Name: HERMANSON COMPANY LLP
Address: 1221 2ND AV N, KENT, WA
Contractor License No: HERMACL005BJ
DESCRIPTION OF WORK:
RELOCATION OF GRD'S, T -STATS AND 3 TERMINAL UNITS TO ACCOMMODATE NEW TENANT
LAYOUT. INSTALLATION OF ONE NEW TERMINAL UNIT WITH ELECTRIC HEAT, 6 DIFFUSERS,
1 T -STAT AND PLENUM.
Furnace: <100K BTU 0
>100K BTU 0
Floor Furnace 0
Suspended /Wall /Floor Mounted Heater 0
Appliance Vent 0
Repair or Addition to Heat/Refrig /Cooling System.... 1
Air Handling Unit <10,000 CFM 0
>10,000 CFM 0
Evaporator Cooler 0
Ventilation Fan connected to single duct 0
Ventilation System 0
Hood and Duct 0
Incinerator: Domestic 0
Commercial /Industrial 0
MECHANICAL PERMIT
EQUIPMENT TYPE AND QUANTITY
* *continued on next page **
M05 -082
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 575 -9700
Phone: 206 - 575 -9700
Expiration Date:08 /25/2006
Steven M. Mullet, Mayor
Steve Lancaster, Director
M05 -082
06/08/2005
12/05/2005
Fees Collected: $500.08
International Mechanical Code Edition: 2003
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 6
Thermostat 1
Wood /Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment... 0
Printed: 06 -08 -2005
Permit Center Authorized Signature:
Signatur:
doc: IMC- Permit
City Vim Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: ci.tukwila.wa.us
Print Name: (JQd 1 . ` C mansor •
M05 -082
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: M05 -082
Issue Date: 06/08/2005
Permit Expires On: 12/05/2005
Date: lv^ezJ.S
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granti r • of this permi does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulatin• c•nstruction • he performance of work. I am authorized to sign and obtain this mechanical permit.
Date: e0/e /06
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
Printed: 06 -08 -2005
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2623049143 Permit Number: M05-082
Address: 655 ANDOVER PK W TUKW Status: ISSUED
Suite No: Applied Date: 05/31/2005
Tenant: CAREER EDUCATION CORPORATION Issue Date: 06/08/2005
1: ** *BUILDING DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
6: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Conditions
* *continued on next page **
M05 -082
Printed: 06 -08 -2005
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any
regulating construction or the performance of work.
Signature:
n ^ ,
Print Name:
doc: Conditions
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
M05 -082
of law and ordinances
other work or local laws
Date:
cP /gin6
Printed: 06 -08 -2005
SITE LOCATION
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: b5b ANE OVER PARK 1,J FST
Tenant Name: eARES {? EbtrAT1OW (OR l A-rION
Property Owners Name: A LiA541khjWW REAL- SISMTS I-ULDI
Mailing Address: f 00 UN1 VF_Lj11 /WEN UP, SI) I TE 6000, SEAMS
T1
City
CONTACT. PERSON
��-C.1 1- •l.��- 11�!'� Day Telephone: 2 P .5 7 F7 qn
Mailing Address: 1 221 2nd Ave.. fl . '/ ,, ±
Name:
E -Mail Address:
GENERAL CONTRACTOR INFORMATION:- (Mechanical Contractor information on back page)
Company Name: - TI)RNR CONSTRUCTION
Mailing Address: 530 1TI'1 AV'EWJ() 5 , SUITE 4CX)
Contact Person: ,SCO L.AMAR
E -Mail Address:
Contractor Registration Number: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
ARCHITECT OF RECORD= All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
ENGINEER OF RECORD- All plans must be wet stamped by Engineer of Record
Company Name: j- RIV1A 1' 7K1 (»~i LLP
Mailing Address: t 22 2111) 1rEl.1l NI
Contact Person: DAVE N -HRI 4
E -Mail Address: DtAN= tiRFN@ I-4 .0 K1f`1SON , COM
lapplicationslpermit application (7 -2004)
Page 1
w
iIIKWII A
W
Building Permit No.
Mechanical Permit No. 1105-08,2
Public Works Permit No.
Project No.
(For office use only)
King Co Assessor's Tax No.: 2 6 0 41919 3
Suite Number: RU1LDINE 7 Floor: 2
New Tenant: ❑ Yes ' .. No
City
14 A
State Zip
City � State Zip
Fax Number: 2C<_ r • 7b g'"W
SSA1rLL LI A 98 IA4
State Zip
Day Telephone:206 - 505' 6 760
Fax Number: 2t* ey5 - _6701
Zip
City
Day Telephone:
Fax Number:
State
hIT >v A 9803 2
City State Zip
Day Telephone: 253 •796 - 5879
Fax Number: 206 ' 575 - 9000
Valuation of Project (contractor's bid price): $ Existing Building Valuation: $
Scope of Work (please provide detailed information):
'applications\ permit application (7.2004)
BUILDING PERMIT INFORMATION - 206 -431 -3670
Will there be new rack storage? ❑ .. Yes ❑ ...No
FIRE PROTECTION /HAZARDOUS MATERIALS:
0...Sprinklers ❑...Automatic Fire Alarm
If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
''For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ ..No If "yes ", explain:
❑...None ❑...Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑...Yes ❑...No
If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
Page 2
Existing
Interior
Remodel
Addition to
Existing
Structure
New
Type of
Construction
per IBC
Type of
Occupancy per
IBC
1" Floor
2 " Floor
3t° Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
Valuation of Project (contractor's bid price): $ Existing Building Valuation: $
Scope of Work (please provide detailed information):
'applications\ permit application (7.2004)
BUILDING PERMIT INFORMATION - 206 -431 -3670
Will there be new rack storage? ❑ .. Yes ❑ ...No
FIRE PROTECTION /HAZARDOUS MATERIALS:
0...Sprinklers ❑...Automatic Fire Alarm
If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
''For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ ..No If "yes ", explain:
❑...None ❑...Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑...Yes ❑...No
If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
Page 2
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
6
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
Thermostat
i'
15 -30 HP /1,000,000 BTU
Suspended /Wall/Floor
Mounted Heater
Ventilation System
Wood /Gas Stove
-
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood
Water Heater
50+ HP /1,750,000 BTU
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator - Comm /Ind
Other Mechanical
Equipment
I
£L. F1 EAT
Teo,' NAL. UNIT,
MECHANICAL PERMIT INFORMATION— 206 -431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: liERMA 1450N COMPANY LLP
Mailing Address: 1221 2N' AV IJ
Contact PersonJA 4-1- RM+w33N
E -Mail Address: JANA4 He-RMA-NSON • COM
Contractor Registration Number: HERM4 C L COS CiJ Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $
I HERE
PENALT
BUILDIN
Signatur
Scope of Work (please provide detailed information):
RELOCATION OF tD s , T 1'4 I) 3 TE1ZMINAL UN To IstuovimoUR7E
NPNV jeNflN7 )A1 OUT • INSTALLATION ON F NSW TERM IIVA( VNIT WITH
�LFLT IC H 1r-�11 , b DI-FVS gS _ 11 -S T , AND PLSNUM
Use Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric B Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
PERMIT APPLICATION NOTES— Applicable to all permits in this application
Value of Construction -In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
ERTIFY T
ERJURY
Print Name: a }41:: tU
Mailing Add ess: 1221 2ND , r\VNUS N
I Date Application Accepted:
tapplications'permit application (7.2004)
NT LIA To 32
City State Zip
Day Telephone: 253 - 790 - G050
Fax Number: 2S3 - oS0 - 3470
AVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
IZED�Gt — •
Page 4
Date:
J /3 ) Jo
Da Telephone: 253' 7%' 5650
'1 - �f,! 1
City
Itt 98032
State Zip
Date Application Expires:
/2- / -D �-
Staff Initials:
i
PUBLIC. WORKS PERMIT INFORMATION— 206 - 433 -0179
Scope of Work (please provide detailed information):
Water District
❑ ...Tukwila ❑ ... Water District #125
❑ ... Water Availability Provided
❑ ...Civil Plans (Maximum Paper Size -22" x 34 ")
❑ ...Technical Infrmation Report (Storm Drainage)
❑ ...Bond 0... Insurance ❑ ...Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Righto f -way Use - Nonprofit for less than 72 hours
❑ ... Righto f -way Use - No Disturbance
❑. ..Construction/Excavation /Fill- Rightof -way
Non Right-of-way
❑ ...Total Cut cubic yards
❑ ...Total Fill cubic yards
❑...Sanitary Side Sewer
❑ ... Cap or Remove Utilities
❑ ... Frontage Improvements
❑...Traffic Control
❑ ... Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ ... Permanent Water Meter Size...
❑ ...Temporary Water Meter Size ..
❑ ... Water Only Meter Size
❑ ...Sewer Main Extension Public
❑ ...Water Main Extension Public
\applicationstpertnit application (7.2004)
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
❑
❑
❑
❑
Call before you Dig: 1 800 - 424 - 5555
..Abandon Septic Tank
..Curb Cut
..Pavement Cut
..Looped Fire Line
WO#
WO#
WO#
Private
Private
Page 3
0... Highline
0... Work in Flood Zone
0... Storm Drainage
❑ ...Renton
Sewer District
❑ ...Tukwila ❑ ... ValVue ❑... Renton ❑ ...Seattle
❑...Sewer Use Certificate 0 ...Sewer Availability Provided 0... Approved Septic Plans Provided
❑ ... Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department.
❑... Geotechnical Report ❑ ...Traffic Impact Analysis
0... Maintenance Agreement(s) ❑ ...Hold Harmless
0... Righto f -way Use - Profit for less than 72 hours
0... Right-o f-way Use — Potential Disturbance
❑ ...Grease Interceptor
❑ ...Channelization
❑ ...Trench Excavation
❑ ...Utility Undergrounding
❑ ...Deduct Water Meter Size
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment
Monthly Service Billing to:
Name;
Mailing Address;
Water Meter Refund /Billing:
Name:
Mailing Address'
Day Telephone:
City
State Zip
Day Telephone.
City
State Zip
m+. �vw.... .��__.— .w...wwr.w.>�.e�.i:'i.�. r�ie..r e.r .•51:•+4'1•• rt�.�vliv va
ACCOUNT ITEM LIST:
Description
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2623049143 Permit Number: M05 -082
Address: 655 ANDOVER PK W TUKW Status: APPROVED
Suite No: Applied Date: 05/31/2005
Applicant: CAREER EDUCATION CORPORATION Issue Date:
Receipt No.: R05 -00844 Payment Amount: 406.06
Initials: SKS Payment Date: 06/08/2005 09:48 AM
User ID: 1165 Balance: $0.00
Payee: HERMANSON COMPANY LLP
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 39260
MECHANICAL - NONRES
406.06
Account Code Current Pmts
000/322.100 406.06
Total: 406.06
3938 06/08 9716 TOTAL 406.06
Printed: 06 -08 -2005
c.) O
co W .
9
W O
2
Q :
_.
z �.
O
w ~ L `
D 0 :
O N
0 1—
W W
1--
W co
UN
O �
Parcel No.:
Address:
Suite No:
Applicant:
Receipt No.:
Initials:
User ID:
Payee:
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
2623049143
655 ANDOVER PK W TUKW
CAREER EDUCATION CORPORATION
R05-00792
SKS
1165
HERMANSON COMPANY
TRANSACTION LIST:
Type Method
Payment Check 1517
Description
RECEIPT
ACCOUNT ITEM LIST:
Description Account Code
PLAN CHECK - NONRES 000/345.830
Permit Number:
Status:
Applied Date:
Issue Date:
Payment Amount:
Payment Date:
Balance:
Amount
94.02
Current Pmts
94.02
Total: 94.02
M05-082
PENDING
05/31/2005
94.02
05/31/2005 08:52 AM
$406.06
3655 05/31 9716 TOTAL 411.90
Printed: 05-31-2005
P pect:
(5 ra.
Type of Inspe
• fr?
ddress:
(PCS" li
ate Called:
Le ( 0 `(
Special Instructions:
Date Wanted: , 1 , a.m.
(P tiff? Os 'En.
Requester:
iZicc k__
Phone e 1 cp ( 7..... Leaoq
L
__INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #1 00, Tukwila, WA 981 88
A pproved per applicable codes.
11/10Y 0
PERM!
( 06)431-3670
orrections required prior to approval.
COMMENTS:
ri $5 ..00 REINSPECTION EE REQUIR . Prior to inspection, fee must be
Id at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
r eceipt No.:
/ e44 1c7ce
Date:
'Date:
z i•- • •
re 6
O 0
C
tow
u.
uj 0
2
g :3
u_
uJ
u) 3
Z p
1- 0
z
uj
2
C.) u)
O —
CI I—
UJ
u j
- w
u d_
0 ' I.
sect:
Type of Inspe io
1
ddres
Date Called:
0 i () 5---
Special
str ct ons:
Date Wanted: ,i a .m.
Ce(f -�
Requester:
P No:
r`"te ti Lp i _7_ as toR
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERM
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 -3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
0K csAAA
Inspector:
(Date: /
� V1
El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
'Date:
Ipject:
_e....A.:Lit. i II •.! is -%'
Type of I - section:
/ ( 1)
/
.1____J.,..I III
Address:
or c
'ate Call -d:
I
Special Instructions:
Date Wanted: LI
0- Ca--
Pans
Requester: /) t
g— i
i
-
I?
.--
•
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 981 88
El Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
PER NO
206)431-3670
Corrections required prior to approval.
COMMENTS: p
El 58 0 REINSPECTION FEE RE UIRED. Pri • to inspection, fee must be
d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
'Receipt No.:
'Date:
• ,,
6 D
0
0
ca 0
• w
u_
ILI 0'
2
g
u_ <
I
LU
' Z
i-0
Z
• uf
2
0
0 —'
ai-
m' tu t
0 .
r:
o
lb
c.) =.
0
Z
PERMIT COORD COF
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M05 -082 DATE: 05 -31 -05
PROJECT NAME: CAREER EDUCATION CORPORATION
SITE ADDRESS: 655 ANDOVER PARK WEST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # /before permit is issued
DEPARTMENTS:
Buildin visio
kt0 4-t-,s-
Public Works ❑
Documents/routing slip.doc
2.28 -02
SI n&t G -z -v;
Fire Prevention 0
Structural ❑
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06 -02 -05
Complete El Incomplete ❑
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined Incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS R9OTING:
Please Route W Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 06 -30 -05
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
PERMIT COORD COPY
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
MINIMUM DUCT INSULATION (R-VALUE LAST UPDATED: 12/20/04
DUCT TYPE lk
DUCT LOCATION
INSULATION
R -VALUE
REMARKS
SUPPLY, RETURN
NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF
BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING
SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES
R -7
1,2,3
OUTSIDE AIR INTAKE
WITHIN CONDITIONED SPACE
VARIES
1,2,4,5
SUPPLY, RETURN, OUTSIDE
AIR INTAKE
NOT WITHIN CONDITIONED SPACE
( IN CONCRETE, IN GROUND
R -5.3
1,2
SUPPLY WITH <55' OR
>105' AIR TEMPERATURE
WITHIN CONDmONED SPACE
R -3.3
1,2
DRAWING INDEX
I KET MO.
SHEET TMI
-tio.00 -
LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET IN1)oc - RAC
w2.02
SECOND FLOOR RAN & SCHEDULES - HVAC
J
A
AC
ACH
ACT
AD
ADD'`
AFF
AFG
AHU
ALUM
AMP /AMPS
AP
ARCH
BC
BDD
BF
BHP
BLDG
BOD
BOP
BOT
BS
BTU
BTUH
CAP
CC
CD
CDWR
CDWS
CFM
CHWR
CHWS
CLG
COL
CONC
COND
CONN
CONT
CONTR
COORD
COP
CT
CU
CW
OB
DBA
DDC
DEFL
DEG
DG
DIA
DMPR
DN
DT
DWG
EXH
EA
EAT
EC
EER
EF
EFF
EL
ELEC /ELECT
EP
EMCS
ENT
EQUIP
ESP
EWT
EXIST
F
FAC
FD
FDC
FF
FIC
FIO
FLA
FLEX
FLR
FOB
FOIC
FOS
FOT
FP
FPM
FSD
FT
FUT
FV
G
GA
GALV
GC
GEN
GPM
GR
GRD
GWB
HD
+HORIZ
HP
HR
HSPF
FIT
HWTG
HWR
HWS
HX
MECHANICAL ABBREVIATIONS
AMPS
AR CONDITIONING
AIR CHANGES PER HOUR
ACOUSTICAL TILE CEILING
ACCESS DOOR
ADDITIONAL
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
ALUMINUM
AMPERAGE
ACCESS PANEL
ARCHITECT
BEADED COLLAR
BACKDRAFT DAMPER
BELOW FLOOR
BRAKE HORSEPOWER
BUILDING
BOTTOM OF DUCT
BOTTOM OF PIPE
BOTTOM
BIRD SCREEN
BRITISH THERMAL UNIT
BRITISH THERMAL UNITS PER HOUR
CAPACITY
CONTROLS CONTRACTOR
CEILING DIFFUSER /CONDENSATE DRAIN
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CUBIC FEET PER MINUTE
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CEILING
COLUMN
CONCRETE
CONDENSATE
CONNECT /CONNECTED
CONNECTION
CONTRACTOR
COORDINATE
COEFFICIENT OF PERFORMANCE
COOUNG TOWER
CUBIC /CONDENSER UNIT
DOMESTIC COLD WATER /CONDENSER WATER
DUCTBOARD /DRY BULB
DECIBEL
DIRECT DIGITAL CONTROL
DEFLECTION
DEGREE/ DEGREES
MODULAR DIFFUSER (GAB CEILING)
DIAMETER
DAMPER
DOWN
MODULAR DIFFUSER ("T -BAR" CEILING)
DRAWING
EXHAUST
EACH
ENTERING AIR TEMPERATURE
;EGGCRATE GRILLE /END CAP /ELEC CONTRACTOR
ENERGY EFFICIENT RATING
EXHAUST FAN
EFFICIENCY
ELEVATION
ELECTRICAL /ELECTRIC
END PLUG
ENERGY MANAGEMENT CONTROL SYSTEM
ENTERING
EQUIPMENT
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXISTING
FAHRENHEIT
FIRE ALARM CONTRACTOR
!FIRE DAMPER
FIRE DEPARTMENT CONNECTION
FINISHED FLOOR
FURNISHED AND INSTALLED BY CONTRACTOR
FURNISHED AND INSTALLED BY OWNER
FULL LOAD AMPS
FLEXIBLE
FLOOR
FLAT ON BOTTOM
FURNISHED BY OTHERS. INSTALLED BY CONTRACTOR
FLAT ON SIDE
FLAT ON TOP
FIRE PROTECTION
FEET PER MINUTE
FIRE /SMOKE DAMPER
FOOT /FEET
FUTURE
FACE VELOCITY
GRILLE
GAUGE /GALLON
GALVANIZED
GENERAL CONTRACTOR
GENERAL
GALLONS PER MINUTE
GRILLE
GRILLE /REGISTER /DIFFUSER
GYPSUM WALL BOARD
HEAD
HORIZONTAL
HORSEPOWER
HOUR
HEATING SEASONAL PERFORMANCE FACTOR
HEIGHT
HIGH WALL TRANSFER GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
HEAT EXCHANGER
•
•
HZ
IBC
ICW
ID
IE
IMC
IN
IN WG
IPLV
KW
LAT
LB /LBS
LD /LIN DIFF
LF /LIN FT
LPG
LVG
LWA
LWG
LWR
LWT
MAX
MAU
MBH
MCA
MD
MFR
MISC
MIN
MT
MTD
MUW
N/A
NC
NG /NGAS
NIC
NO
NPCW
OA /OSA
OB
OBD
OD
P
PCF
PD
PH
POC
PRESS
PSI
PSIG
QTY
R
RA
RD /RND
REF
REG
REQ'D
RF
RG
RL
RPM
RS
S
SA
SAT
SD
S/D
SEER
SENS
SG
SL
SM
SPEC
SO
SOG
SP
SOFT
SR
SS
STRUC
T
TA
TEMP
TBD
TG
TOC
TOD
TOS
TOT
TSP
TSTAT
TYP
UH
UNO
V
VIAQC
VD
VEL
VERT
VFD
VOL
W
WB
WG
W/
W/O
W /SF
WSEC
HERTZ
NTERNATIONAL BUILDING CODE
NDUSTRIAL COLD WATER
NSIDE DIAMETER /DIMENSION
NVERT ELEVATION
NTERNATIONAL MECHANICAL CODE
NCHES
NCHES WATER GAUGE
NTEGRATED PART LOAD VALUE
KILOWATTS
LEAVING AIR TEMPERATURE
POUND /POUNDS
LINEAR DIFFUSER
LINEAL FOOT /FEET
LIQUID PROPANE GAS
LEAVING
SOUND POWER
LOW WALL GRILLE
LOW WALL REGISTER
LEAVING WATER TEMPERATURE
MAXIMUM
MAKE UP AIR UNIT
1000 BRITISH THERMAL UNITS
MINIMUM CIRCUIT AMPACITY
MOTORIZED DAMPER
MANUFACTURER
MISCELLANEOUS
MINIMUM /MINUTE
MOUNT
MOUNTED
MAKE -UP WATER
NOT APPLICABLE
NORMALLY CLOSED /NOISE CRITERIA
NATURAL GAS
NOT IN CONTRACT
NORMALLY OPEN /NUMBER
NON- POTABLE COLD WATER
OUTSIDE AIR
OPPOSED BLADE
OPPOSED BLADE DAMPER
OUTSIDE DIAMETER /DIMENSION
PUMP
POUNDS PER CUBIC FOOT
PRESSURE DROP
PHASE
POINT OF CONNECTION
PRESSURE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH GAUGE
QUANITY
RETURN GRILLE /RELOCATED /RETURN
RETURN AIR
ROUND
REFERENCE
REGISTER
REQUIRED
RELIEF
RETURN GRILLE
REFRIGERANT LIQUID
REVOLUTIONS PER MINUTE
REFRIGERANT SUCTION
SUPPLY
SUPPLY AIR
SATURATION
SMOKE DETECTOR
SLIP & DRIVE CONNECTION
SEASONAL ENERGY EFFICIENCY RATING
SENSIBLE
SUPPLY GRILLE
SOUND LINED
SPIRALMATE /SHEETMETAL .
SPECIFICATION
SCREENED OPENING
SLAB ON GRADE
STATIC PRESSURE
SQUARE FEET
SIDE WALL REGISTER
STAINLESS STEEL
STRUCTURAL
TRANSFER
TRANSFER AIR
TEMPERATURE/TEMPORARY
TO BE DETERMINED
TRANSFER GRILLE
TOP OF CONCRETE /CURB
TOP OF DUCT
TOP OF STEEL/TOP OF SLAB
TOTAL
TOTAL STATIC PRESSURE
THERMOSTAT
TYPICAL
UNIT HEATER
UNLESS NOTED OTHERWISE
VOLT
VENT. AND INDOOR AIR QUALITY CODE
VOLUME DAMPER
VELOCITY
VERTICAL
VARIABLE FREQUENCY DRIVE
VOLUME
WALL/WALLS
WET BULB
WATER GAUGE
WITH
WITHOUT
WATTS PER SQUARE FOOT
WASHINGTON STATE ENERGY CODE
MECHANICAL LEGEND
it 1
• 1Ox10
a
lib a 11
10x10 I ,/ 1
• I0x10
0
spy � ROUND DUCT - TURNING UP OR TOWARD
r - ZQIr�
10� ‘D
. 100 ,
BOOT TAP
1 ,1114_,
f=c=1
1=961
!.INNNNW�
'116)111_ SLi
11-6i1-6-fs
150 CEILING SUPPLY AIR DIFFUSER (SHOWN
WITH REDIRECTED AIR CORE)
CEILING RETURN, TRANSFER OR
EXHAUST AIR GRILLE
. SLOTTED DIFFUSER (PLAN VIEW)
XXO ROUND DUCT SYMBOL
XX• FLAT OVAL DUCT SYMBOL
XX' DEGREES SYMBOL
Ei POINT OF CONNECTION
CD1 -100 GRD TAG IDENTIFIER = ;TYPE -CFM
80 SIZE
0 THERMOSTAT/TEMPERATURE SENSOR
Q HUMIDITY SENSOR
EXISTING DUCTWORK
DEMO DUCTWORK
1
a- OMR
a-- a - aMR --s
ume
1?- cars -- - COM ---;
,_ a -- cows --4
ire
6- OM - CONS -4
RECTANGULAR SUPPLY AIR DUCT -
TURNING UP OR TOWARD
RECTANGULAR SUPPLY AIR DUCT -
TURNING DOWN OR AWAY
RECTANGULAR EXHAUST OR RETURN AIR
DUCT - TURNING UP OR TOWARD
RECTANGULAR EXHAUST OR RETURN AIR
DUCT - TURNING DOWN OR AWAY
ROUND DUCT - TURNING DOWN OR AWAY
OVAL DUCT - TURNING UP OR TOWARD
OVAL DUCT - TURNING DOWN OR AWAY
DUCT OVERLAP
45' TAP
VOLUME DAMPER
CHANGE OF ELEVATION RISE(R) DROP(D)
TRANSITION
TURNING VANES /SPUTTERS
DUCT MOUNTED SMOKE DETECTOR
BACK DRAFT DAMPER
FLEXIBLE DUCT
AIR FLOW DIRECTION FORCED AIR)
NR FLOW DIRECTION (DRAWN AIR)
MOTOR OPERATED DAMPER
FLEX CONNECTION
SMOKE DAMPER
FIRE DAMPER
COMBINATION FIRE & SMOKE DAMPER
SOUND TRAP
ACCESS DOORS
ACOUSTICALLY LINED DUCT (SOUND LINED)
DUCT BOARD
FABRIC DUCT
VAV BOX
STATIC PRESSURE SENSOR
WALL - MOUNTED GRILLE
0 PIPE ELBOW UP
PIPE ELBOW DN
DIRECTION OF FLOW
DIRECTION OF SLOPE DOWN
PLUG OR CAP
GAS PRESSURE REDUCING ASSEMBLY
SOLENOID VALVE
PUMP
CHILLED WATER SUPPLY
CHILLED WATER RETURN
REFRIGERANT LIQUID
REFRIGERANT SUCTION
NATURAL GAS
LIQUID PROPANE GAS
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
HEATING WATER SUPPLY
HEATING WATER RETURN
CONDENSATE
r
_ 1.5 1.5 1.5
1.0 1.0 + 1.5
0.75 1.0 1.0
MECHANICAL GENERAL NOTES
1 . THE 2003 18 N WSEC 2003 IYC 200E ��� AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO
2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE.
3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.
4. VERIFY ALL P P CONDITIONS, NGEWITHNTA DETAILS, ETC. NOTIFY ENGINEER OF ANY
5. WHEN �� ONT THE ENGINEER VEER PRIOR SIMILAR ROCEEa �UESTIRONS�GW�NOT B THE RESOLVEb DETAILS THIS
6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL. CONTRACTOR UNLESS
NOTED OTHERWISE.
7. ALL JOINTS IN SUPPLY AND RETURN AIR DUCTS SHALL BE SEALED TO SMACNA C CLASS, OR ABOVE.
8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE.
9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED.
10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL
BURNING EQUIPMENT, AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST
OUTLET.
11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OR THE FOLLOWING:
A. 0% TO 100% OF THE DESIGN SUPPLY AIR
B. CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE
BUILDING COOLING LOADS.
C. INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED.
12. OUTS AIR WHI�H��bSE L i�1�01+�lAT�ICALLY�WHEN P SYSTEM IS OFF OR POWER fAILUR�E�ZAS REWIRED BY
ENERGY CODE.
13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGWWABLE CAPABLE OF BEING SET FOR SEVEN DIFFERENT
S�EfP01NT A�HU S�FU4LDLSII�LUDE OF AI BE BETWEEN OF RES��NT DAY
� COOLING
SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS.
14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SWELL BE PROVIDED TO THE BUILDING OWNER WITHIN
90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING
MANUAL AND BALANCED MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. AL L HVAC SYSTEMS
SHALL B aN gTROI E�AND A WRITfEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER.
HVAC c SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE
WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISIONING REPORT OF TEST PROCEDURES
AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL
D CERTIFICATE RESULTS OF OCCUPANCY. A
COMPLETE E O FINAL COMMISSIONING I
NGM B�LAN�CING�RECDRAWINGS AS PER THE WASRHI�TON TO
STATE
ENERGY CODE.
15. DUCT SYSTEMS SHALL COMPLY WITH MECHANICAL CODES AND SMACNA STANDARDS. DUCTS 28" AND LARGER,
WHICH ARE SUSPENDED MORE THEN 12' BELOW STRUCTURAL SYSTEM, SHALL BE EARTHQUAKE BRACED.
16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT
MANUAL, SEIZMIC HAZARD B.
17.
'• O
'E'
VIDL AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED
18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE
CAULKING.
19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING
IN EXCESS OF 2000 CFM PER CODE. OKE DETECTORS SHALL BE FURNISHED AND NSTALLED BY ELECTRICAL
CONTRACTOR UNLESS NOTED OTHERWISE. POWER-WIRING AND INTERLOCK TO ARE ALARM SYSTEM BY ELECTRICAL
CONTRACTOR AS APPLICABLE.
20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR.
21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY
ELECTRICAL CONTRACTOR.
22. FOR VERTICAL JN SRINSIDE TIGHT" SHAFTS
TH HAFT R SHALL THE �F DEDOH A CONTINUO OCCUR:
S SEAL FOR THE
LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC_)
-TOP AND BO WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC)
IS WO ACCEPTC�KINEG PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL
SEALED N dN NTH SIgEST THE PEHE SHAFT (DUCTWORK, CONDUIT, PIPING....) SHALL BE
-USE SECTICN 905 OF THE 2003 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE
GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION.
-ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF
ROOM/SHAFT PRESSURE.
23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT
REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING
SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL.
INSULATE DUCT PER NOTE 11 ABOVE.
24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING AND CONNECTIONS ARE APPROXIMATE.
COORDINATE FINAL LOCATIONS WITH OVER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS
AND DETAIL DRAWINGS WHEN APPLICABLE.
1. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS
2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED
DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS.
3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS.
4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL
CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R -7 FOR REST OF
INSTALLATION).
5. R -7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL F: DEDICATED OUTSIDE NR SYSTEM
AND LESS THAN 2,800 CFM.
MINIMUM PIPE INSULATION (INCHES) LAST UPDATED: , z /o /o
INSULATION CONDUCTIVITY
SERVICE
HWS&R
HWS&R
CMMSdcR
FLUID
TEMP 'F
1 41 -200
105 -140
40 -45
CHWS&R <40 0.23 -0.27 75 1.0 1.0
CWS&R 40 -45 0.23 -0.27 75 0.5 0.5
CONDENSER WATER (FOR NON - ECONOMIZER SYSTEMS - INSULATION IS NOT REQUIRED
CONDUCTIVITY
RANGE
0.25 -0.29
0.24 -0.28
0.23 -0.27
•
MEAN TEMP
RATING 'F
125
100
75
RUN -OUTS
UP TO 2
0.5
0.5
0
0.5
NOMINAL PIPE DIAMETER (IN)
4 5ftni 0 12,
. I .
•
APN NUMBER
2623049143
LEGAL DESCRIPTION
BOA 143 LOT 3 OF CITY OF 1UKMALJI SHORT PLAT NO
1.97-0019 RECORDING NO 871101A0018AID SHORT PLAT
DEFIED - PORTION OF E 112 OF NYV 114 OF SE 1M, BEGIN NE
CORNER OF SAID E 1R BEING N 11-05-42 W 1339.34 FT FROM
NE CORNER OF SE 111TH S 01J7,29 W 1322.34 FT TO
SOUTHEAST CORNER 1Fi N E74612 MI169.36 FT TO W LINE OF
E 16934 PT OF SAID E 1R ?H N 014749 E 10.30 FT TO N IJNE
OF SAID E 1R TH S !A-05-42 E 659.31 FT TO POB LESS PORTION
FOR 59T11 AVE SOUTH LESS PORTIONS FOR STREETS AS
CONVEYED BY DEED, RECORDING NO 7907120710 LESS
•
PORTION CONVEYED TO CITY OF TUKYNLA FOR ROAD BY
DEED, RECORDING NO 4408290.127
7035 M,oQunt corn
(40//n&
fly of bats
BUILDING DIVISION
. Capoaatc rf'V
C xvxMe a 3
j .-
.
t es W+w
,
Evans Bieck Or
BLS COPY
No. Aiii5 .1)82„
avow r subject merrors and =Wow
construction documents doss not auaiati.
d MOM ads or ordinance. Wipt
melons Is scloiarMOPd:
SITE MAP
NO SCALE
r.. •• •
. ,q Blvd
A
1
11E PERMIT
POR;
VICINITY MAP
""' I � NO SCALE
Pliong
j PCITE: Reviskxis WI !squint a new pin submittal
and may Include additional plan review feu.
lb ch ewe shell be reeds to the awe
of work without prior approval et
Tubas ibrikiing Division.
7Lkwla
DDQSION
NICE1VED
CITY OF TUKWiLA
MAY 3 12N5
PERMIT CENTER
ISSUE FOR PERMIT
•
Hermanson
1?2 l�rn�oiron�Ca� y UP Norlh
Knit, Washington 980332
Tel (208) 57S- -97+00
Fax. (20S) 575 -98cm
www herm•nson.con,
Contactor Rog HEAWCUXIMIJ
IAD+T TI
C.E.0 Boiling 7 Floor 2
655 Andover Park West
Tukwila, WA
I MIRES ,/z./ ob
Revisions
LJ_ __ REVIEWED
..�
JUN - 120(6
Of Tukwila
5/27/05 KB ISSUE FOR PERMIT
No. Dots Description
Design Team
Design KB
Drown ER
Checked KB
Scale AS NOTED
Drowinq Number C- 0045 -g7$
Project Number 10 -5-278
Issue Dote 5127/05
LEGEND, ABBREVIATIONS,
GENERAL NOTES, &
SHEET INDEX - HVAC
M0.00
MOSQ
-
Ii 4
44f)
Hermanson
Honnorson Company UP
Inl 2nd hems North
KM+t, Woolinton 950312
Tel (206) 575 -9700
Fax (206) 575 -9600
VANN hennenson COT
Contractor Rog 9: HE1111a005I
IAD+TTI
C.E.0 Building 7 Floor 2 .
655 Andover Park West
Tukwila, WA ;
\)• 1 • •
� R 1
,,
' -1 lt' .
-, t \
.J • AL ,
1 DAMS 1/29" �
Revisions
5/27/05 KB ISSUE FOR PERMIT
it o. Dote By Description
Design Team
Design KB
Drown ER
Checked KB
Scale AS NOTED
Drow;n9 Number C- 0045 - 278
Project Number 10- 5--278
Issue Date 5/27105
SECOND FLOOR PLAN
& SCHEDULES
- HVAC
M2.02
•
KNEW
PAIL
. REMOVE DUCT
11 1111
3 11
r • 1
NEU
aye
•
OM WO
i11111..11111.•
MEIMMINIEMMI i
•••••■FiRieMMILIIM
•
Illeireenzenermann
uuuauuuuuauuaaui
Immosimiummounw
111111111111111111111111111111111 111111111 II I
a� ■ ■ ■ ■ ■ ■1 t ■t I I. I 1
ua.uuuuauiiio I 1
IJRR i uu•F � �I
aw
uuuuui
1 u1a1 i
.muur
aiivauuu111► i
a.rnuu,
aauue
i uuaiu 180
NIL uuuuS
It iRuL
t llio
EN
• Er
Ilan
i
36 SE Al ClURI 49
el ASSR #
Li-o7_51 • • Mallill lit CORRIDOR CIF
IMINIMINIII willitit 202 204
iiiNENffiliiiiiMilialiihn -
in ............iii:
,mi monmamminwom
inell01111111111111111111•Minn11111 a Oa
, N11111111111111111111111111111111111111" 1111112-
11.111111111111111111111111111E1111111111101 owe
/I
i ■aitii�iiari Dr
• tUiIURIRiUUiL_
111111111111111111111111111111111111111111i it.:4
imumuramrs " 1111
SERIMINIMIIIIIP
IdLI e
Y&N.Air
3CI ZTURE
COMPUTER
LAB
O -
MUM
MIND MIND MIND M - IM - MOM•MMI=
OMB MN=
AMID
A I . OMR
•
CLASSROOM
I 211
OMR
- -- ---- --
I /MI , - M • - M , - -
e
CAP
REMOVE DUCT C
I
I
I
I
1
I
SEWONG LAB
I
I
I
I
I
I
I
I
I
I
1
I
r ,
I
1
AREA OF WORK
SCALE: 1/8 = 1' -0'
• •
SECOND FLOOR PLAN - HVAC
REMARKS
1
2
3
4
5
6
7
6
DISCONNECT BY ELECTRICAL
SERIES FM POWERED TERMINAL UNIT WITH HEAT - SIZE AS LISTED, PRESSURE INDEPENDENT, FACTORY OPTIONS INCLUDE:
•- EXTENDED DAMPER 1/2 DIVA. SWJ T
- FACTORY INSTALLED 1' THROW -AWAY FLIERS
- UNIT CONTROLS AND AUTO RESET 130 DEG. F. THERMOSTAT BY CONTROLS CONTRACTOR
-- MATT LNER FACED I TERNAL INSULATION TO M RSTREIM
- MARE SPEED FAN CONTROL
- 24V TRANSFORMER, 50 VA MIN RATING
- HEAT STAGING & FIN CONTROL THROUGH FACTORY WIRED RELAYS
460V/3PH TERMINAL UNITS REQUIRE A FOUR WIRE POWER FEED IN ORDER TO SUPPLY 277V/1 PH POWER TO THE FAN MOTOR
INE111 VAV BOX. PROVIDE NEW 7 -DAY PROGRAMMABLE T -STAT
EXISTING VAV BOX. REBALANCE ONLY
EXISTING via RELOCATED AS SHOWN ON DRAINi1NGS ANO REBAUNCED
EXISTING VIW BOX NOT M SCOPE OF WORK
EXISTING WM BOX. SET AT LOW SPEED AND REBP1ANCE
..•Dt31-.,.
CONSTRUCTION NOTE$:
LI)RELOCATE TERMINAL UNIT INTO SEWING lA6 TO ACCOMMODATE
NEW TENANT LAYOUT
0 RELOCATE TERMINAL UNIT INTO SEWING LAB TO ACCOMMODATE
NEW TENANT LAYOUT
0 DEMO SECTION OF 180 AND 120 ROUND MEDIUM
PRESSURE DUCT AS SHOWN AND REPLACE WITH NEW 260 AND 220.
0 RELOCATE DIFFUSER SOUTH INTO NEW COMPUTER LAB
O RELOCATE DIFFUSER WEST INTO NEW COMPUTER LAB
0 CONNECT DIFFUSER TO NEW TERMINAL UNIT
Q7 RELOCATE DIFFUSER EAST INTO SEWING LAB
0 NEW DIFFUSER
0 RELOCATE T-STAT SOUTH WEST INTO NEW COMPUTER LAB
10 RELOCATE TERMINAL UNIT NORTH EAST INTO SEWING LAB
TO ACCOMMODATE NEW TENANT LAYOUT
11 RELOCATE T-STAT TO EAST WALL OF SEWING LAB
12 RECONNECT DUCTWORK TO TERMINAL UNIT 210
13 RELOCATE RETURN GRILLE WEST INTO NEW LECTURE CLASSROOM
14 RELOCATE RETURN GRILLE SOUTH INTO COMPUTER LAB
15 REBALANCE TERMINAL UNIT AND DIFFUSERS IN EXISTING TENANT AREA
16 RELOCATE RETURN GRILLE EAST INTO NEW SEWING LAB
17 SET SUPPLY AIR TEMPERATURE AT ROOF TOP UNIT TO 55F MIN
18 RELOCATE RETURN GRILLE SOUTH INTO LECTURE CLASSROOM
19 RELOCATE DIFFUSER NORTH INTO EXISTING TENANT AREA
20 REMOVE TRANSFER GRILLES
r
4
TERMINAL UNIT SCHEDULE - ELECTRIC
LAST UPDATED: 5/19/05
TAG
LOCATION
AREA
VAV -201 , BLDG 7, FIR 2
VAV -202 BLDG 7, FIR 2
EXIST. Oita
EXIST. OFFICE
VAV -203 BLDG 7, FIR 2
EXIST. OFFICE
VAV -204 BLDG 7. FIR 2
EXIST. OFFICE
VAV -205 BLDG 7. FIR 2
cast. OFFICE
VAV -206 BLDG 7. FLR 2
SEWING UB
VAV -207 BLDG 7, FIR 2
EXIST. OFFICE
VAV -208 BLDG 7, FIR 2
COMPUTER LAB
VAV -209 BLDG 7. FIR 2
SEWING U18
VAV -210 BLDG 7, FIR 2
SEWING 1118
VAV -211 , BLDG 7, FIR 2
COMPUTER LIIB
VAV -212 BLDG 7, FIR 2
SEWING LAB
VAV -219 BLDG 7. Fla 2
lsCnlns ores
BASIS OF
DESIGN
INDUCTO H*S1500
I NDUCTO
REDDI
VEUCTO
INDUCTO
TUTUS NOV
waUcTO ►ss2000
TITUS MY
REDDI
NNDUCTO
TITUS PMFV
ToMPwsTER
INVIROTIC MA 1490
NUT
Duk
FMI
CFM
IUII
IRAN
CFM
N1
1,600
NA
NA
1,500 , N►
1,200 C NA
r
N11
600 NA
NA
NA
10
840
200
1,755 440
1,000 270
NA
10
NA
180
12
990
NA
90
1,090
1.000
900
1.600
NA
8'ro
14
470 _
•4
FAN MOTOR
HP
NA
•
NA
V/PH
NA
NA
NA
NA
NA
ELECTRIC HEATING Coll
Cal
1500
1200
600
400
1600
I
NA NA 840
NA NA 1755
NA NA , 1080
NA NA 180
ANA NA 1080
NA NA 1080
NA NA 1/2 277/1 f 1 o
TEMP.
RISE T
35.7
34.1
26.2
39.4
35.0
49.5
11.7
43.7
18.9
KW
17.0
13.0
5.0
22.0
2.0
17.0
4.0
5.0
9.0
NO. OF
sr*;ES
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
2
V/PH R WRKS
7
7
277/1 A 7
5
7
5
480/3 I 8
6
277/1 6
480/3 6
277/1 I 5
277/1
5
4&J /3 1.2,9.4
PECENED
cv OF TUKWILA
MAY 3 1 2115
IERMTT CENTER
ISSUE FOR PERMIT