HomeMy WebLinkAboutPermit M05-082 - CAREER EDUCATION CORPORATIONCAREER EDUCATION CORPORATION 655 ANDOVER PK W M05-082 City Tukwila Parcel No.: 2623049143 Address: 655 ANDOVER PK W TUKW Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Mechanical: $30,000.00 Type of Fire Protection: doc: IMC- Permit Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us CAREER EDUCATION CORPORATION 655 ANDOVER PK W, TUKWILA WA LOWE NORTHWEST INVESTOR PRO 600 UNIVERSITY ST, SUITE 2820 JANA HERMANSON - 1221 2 AV N, KENT, WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N, KENT, WA Contractor License No: HERMACL005BJ DESCRIPTION OF WORK: RELOCATION OF GRD'S, T -STATS AND 3 TERMINAL UNITS TO ACCOMMODATE NEW TENANT LAYOUT. INSTALLATION OF ONE NEW TERMINAL UNIT WITH ELECTRIC HEAT, 6 DIFFUSERS, 1 T -STAT AND PLENUM. Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 1 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -082 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 575 -9700 Phone: 206 - 575 -9700 Expiration Date:08 /25/2006 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -082 06/08/2005 12/05/2005 Fees Collected: $500.08 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 6 Thermostat 1 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment... 0 Printed: 06 -08 -2005 Permit Center Authorized Signature: Signatur: doc: IMC- Permit City Vim Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Print Name: (JQd 1 . ` C mansor • M05 -082 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -082 Issue Date: 06/08/2005 Permit Expires On: 12/05/2005 Date: lv^ezJ.S I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granti r • of this permi does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatin• c•nstruction • he performance of work. I am authorized to sign and obtain this mechanical permit. Date: e0/e /06 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 06 -08 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049143 Permit Number: M05-082 Address: 655 ANDOVER PK W TUKW Status: ISSUED Suite No: Applied Date: 05/31/2005 Tenant: CAREER EDUCATION CORPORATION Issue Date: 06/08/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M05 -082 Printed: 06 -08 -2005 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. Signature: n ^ , Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 M05 -082 of law and ordinances other work or local laws Date: cP /gin6 Printed: 06 -08 -2005 SITE LOCATION CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: b5b ANE OVER PARK 1,J FST Tenant Name: eARES {? EbtrAT1OW (OR l A-rION Property Owners Name: A LiA541khjWW REAL- SISMTS I-ULDI Mailing Address: f 00 UN1 VF_Lj11 /WEN UP, SI) I TE 6000, SEAMS T1 City CONTACT. PERSON ��-C.1 1- •l.��- 11�!'� Day Telephone: 2 P .5 7 F7 qn Mailing Address: 1 221 2nd Ave.. fl . '/ ,, ± Name: E -Mail Address: GENERAL CONTRACTOR INFORMATION:- (Mechanical Contractor information on back page) Company Name: - TI)RNR CONSTRUCTION Mailing Address: 530 1TI'1 AV'EWJ() 5 , SUITE 4CX) Contact Person: ,SCO L.AMAR E -Mail Address: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD= All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: ENGINEER OF RECORD- All plans must be wet stamped by Engineer of Record Company Name: j- RIV1A 1' 7K1 (»~i LLP Mailing Address: t 22 2111) 1rEl.1l NI Contact Person: DAVE N -HRI 4 E -Mail Address: DtAN= tiRFN@ I-4 .0 K1f`1SON , COM lapplicationslpermit application (7 -2004) Page 1 w iIIKWII A W Building Permit No. Mechanical Permit No. 1105-08,2 Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 2 6 0 41919 3 Suite Number: RU1LDINE 7 Floor: 2 New Tenant: ❑ Yes ' .. No City 14 A State Zip City � State Zip Fax Number: 2C<_ r • 7b g'"W SSA1rLL LI A 98 IA4 State Zip Day Telephone:206 - 505' 6 760 Fax Number: 2t* ey5 - _6701 Zip City Day Telephone: Fax Number: State hIT >v A 9803 2 City State Zip Day Telephone: 253 •796 - 5879 Fax Number: 206 ' 575 - 9000 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): 'applications\ permit application (7.2004) BUILDING PERMIT INFORMATION - 206 -431 -3670 Will there be new rack storage? ❑ .. Yes ❑ ...No FIRE PROTECTION /HAZARDOUS MATERIALS: 0...Sprinklers ❑...Automatic Fire Alarm If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) ''For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ ..No If "yes ", explain: ❑...None ❑...Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑...Yes ❑...No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. Page 2 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 2 " Floor 3t° Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): 'applications\ permit application (7.2004) BUILDING PERMIT INFORMATION - 206 -431 -3670 Will there be new rack storage? ❑ .. Yes ❑ ...No FIRE PROTECTION /HAZARDOUS MATERIALS: 0...Sprinklers ❑...Automatic Fire Alarm If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) ''For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ ..No If "yes ", explain: ❑...None ❑...Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑...Yes ❑...No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. Page 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 6 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Thermostat i' 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove - 30 -50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Comm /Ind Other Mechanical Equipment I £L. F1 EAT Teo,' NAL. UNIT, MECHANICAL PERMIT INFORMATION— 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: liERMA 1450N COMPANY LLP Mailing Address: 1221 2N' AV IJ Contact PersonJA 4-1- RM+w33N E -Mail Address: JANA4 He-RMA-NSON • COM Contractor Registration Number: HERM4 C L COS CiJ Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ I HERE PENALT BUILDIN Signatur Scope of Work (please provide detailed information): RELOCATION OF tD s , T 1'4 I) 3 TE1ZMINAL UN To IstuovimoUR7E NPNV jeNflN7 )A1 OUT • INSTALLATION ON F NSW TERM IIVA( VNIT WITH �LFLT IC H 1r-�11 , b DI-FVS gS _ 11 -S T , AND PLSNUM Use Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric B Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES— Applicable to all permits in this application Value of Construction -In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. ERTIFY T ERJURY Print Name: a }41:: tU Mailing Add ess: 1221 2ND , r\VNUS N I Date Application Accepted: tapplications'permit application (7.2004) NT LIA To 32 City State Zip Day Telephone: 253 - 790 - G050 Fax Number: 2S3 - oS0 - 3470 AVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. IZED�Gt — • Page 4 Date: J /3 ) Jo Da Telephone: 253' 7%' 5650 '1 - �f,! 1 City Itt 98032 State Zip Date Application Expires: /2- / -D �- Staff Initials: i PUBLIC. WORKS PERMIT INFORMATION— 206 - 433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ... Water District #125 ❑ ... Water Availability Provided ❑ ...Civil Plans (Maximum Paper Size -22" x 34 ") ❑ ...Technical Infrmation Report (Storm Drainage) ❑ ...Bond 0... Insurance ❑ ...Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Righto f -way Use - Nonprofit for less than 72 hours ❑ ... Righto f -way Use - No Disturbance ❑. ..Construction/Excavation /Fill- Rightof -way Non Right-of-way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑...Sanitary Side Sewer ❑ ... Cap or Remove Utilities ❑ ... Frontage Improvements ❑...Traffic Control ❑ ... Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ... Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ... Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public \applicationstpertnit application (7.2004) Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ ❑ ❑ ❑ Call before you Dig: 1 800 - 424 - 5555 ..Abandon Septic Tank ..Curb Cut ..Pavement Cut ..Looped Fire Line WO# WO# WO# Private Private Page 3 0... Highline 0... Work in Flood Zone 0... Storm Drainage ❑ ...Renton Sewer District ❑ ...Tukwila ❑ ... ValVue ❑... Renton ❑ ...Seattle ❑...Sewer Use Certificate 0 ...Sewer Availability Provided 0... Approved Septic Plans Provided ❑ ... Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. ❑... Geotechnical Report ❑ ...Traffic Impact Analysis 0... Maintenance Agreement(s) ❑ ...Hold Harmless 0... Righto f -way Use - Profit for less than 72 hours 0... Right-o f-way Use — Potential Disturbance ❑ ...Grease Interceptor ❑ ...Channelization ❑ ...Trench Excavation ❑ ...Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name; Mailing Address; Water Meter Refund /Billing: Name: Mailing Address' Day Telephone: City State Zip Day Telephone. City State Zip m+. �vw.... .��__.— .w...wwr.w.>�.e�.i:'i.�. r�ie..r e.r .•51:•+4'1•• rt�.�vliv va ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049143 Permit Number: M05 -082 Address: 655 ANDOVER PK W TUKW Status: APPROVED Suite No: Applied Date: 05/31/2005 Applicant: CAREER EDUCATION CORPORATION Issue Date: Receipt No.: R05 -00844 Payment Amount: 406.06 Initials: SKS Payment Date: 06/08/2005 09:48 AM User ID: 1165 Balance: $0.00 Payee: HERMANSON COMPANY LLP RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 39260 MECHANICAL - NONRES 406.06 Account Code Current Pmts 000/322.100 406.06 Total: 406.06 3938 06/08 9716 TOTAL 406.06 Printed: 06 -08 -2005 c.) O co W . 9 W O 2 Q : _. z �. O w ~ L ` D 0 : O N 0 1— W W 1-- W co UN O � Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 2623049143 655 ANDOVER PK W TUKW CAREER EDUCATION CORPORATION R05-00792 SKS 1165 HERMANSON COMPANY TRANSACTION LIST: Type Method Payment Check 1517 Description RECEIPT ACCOUNT ITEM LIST: Description Account Code PLAN CHECK - NONRES 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 94.02 Current Pmts 94.02 Total: 94.02 M05-082 PENDING 05/31/2005 94.02 05/31/2005 08:52 AM $406.06 3655 05/31 9716 TOTAL 411.90 Printed: 05-31-2005 P pect: (5 ra. Type of Inspe • fr? ddress: (PCS" li ate Called: Le ( 0 `( Special Instructions: Date Wanted: , 1 , a.m. (P tiff? Os 'En. Requester: iZicc k__ Phone e 1 cp ( 7..... Leaoq L __INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 981 88 A pproved per applicable codes. 11/10Y 0 PERM! ( 06)431-3670 orrections required prior to approval. COMMENTS: ri $5 ..00 REINSPECTION EE REQUIR . Prior to inspection, fee must be Id at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. r eceipt No.: / e44 1c7ce Date: 'Date: z i•- • • re 6 O 0 C tow u. uj 0 2 g :3 u_ uJ u) 3 Z p 1- 0 z uj 2 C.) u) O — CI I— UJ u j - w u d_ 0 ' I. sect: Type of Inspe io 1 ddres Date Called: 0 i () 5--- Special str ct ons: Date Wanted: ,i a .m. Ce(f -� Requester: P No: r`"te ti Lp i _7_ as toR INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0K csAAA Inspector: (Date: / � V1 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: 'Date: Ipject: _e....A.:Lit. i II •.! is -%' Type of I - section: / ( 1) / .1____J.,..I III Address: or c 'ate Call -d: I Special Instructions: Date Wanted: LI 0- Ca-- Pans Requester: /) t g— i i - I? .-- • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PER NO 206)431-3670 Corrections required prior to approval. COMMENTS: p El 58 0 REINSPECTION FEE RE UIRED. Pri • to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: • ,, 6 D 0 0 ca 0 • w u_ ILI 0' 2 g u_ < I LU ' Z i-0 Z • uf 2 0 0 —' ai- m' tu t 0 . r: o lb c.) =. 0 Z PERMIT COORD COF PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M05 -082 DATE: 05 -31 -05 PROJECT NAME: CAREER EDUCATION CORPORATION SITE ADDRESS: 655 ANDOVER PARK WEST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # /before permit is issued DEPARTMENTS: Buildin visio kt0 4-t-,s- Public Works ❑ Documents/routing slip.doc 2.28 -02 SI n&t G -z -v; Fire Prevention 0 Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06 -02 -05 Complete El Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined Incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R9OTING: Please Route W Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06 -30 -05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: PERMIT COORD COPY DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: MINIMUM DUCT INSULATION (R-VALUE LAST UPDATED: 12/20/04 DUCT TYPE lk DUCT LOCATION INSULATION R -VALUE REMARKS SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R -7 1,2,3 OUTSIDE AIR INTAKE WITHIN CONDITIONED SPACE VARIES 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR INTAKE NOT WITHIN CONDITIONED SPACE ( IN CONCRETE, IN GROUND R -5.3 1,2 SUPPLY WITH <55' OR >105' AIR TEMPERATURE WITHIN CONDmONED SPACE R -3.3 1,2 DRAWING INDEX I KET MO. SHEET TMI -tio.00 - LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET IN1)oc - RAC w2.02 SECOND FLOOR RAN & SCHEDULES - HVAC J A AC ACH ACT AD ADD'` AFF AFG AHU ALUM AMP /AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW OB DBA DDC DEFL DEG DG DIA DMPR DN DT DWG EXH EA EAT EC EER EF EFF EL ELEC /ELECT EP EMCS ENT EQUIP ESP EWT EXIST F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GEN GPM GR GRD GWB HD +HORIZ HP HR HSPF FIT HWTG HWR HWS HX MECHANICAL ABBREVIATIONS AMPS AR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL TILE CEILING ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER /CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT /CONNECTED CONNECTION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOUNG TOWER CUBIC /CONDENSER UNIT DOMESTIC COLD WATER /CONDENSER WATER DUCTBOARD /DRY BULB DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/ DEGREES MODULAR DIFFUSER (GAB CEILING) DIAMETER DAMPER DOWN MODULAR DIFFUSER ("T -BAR" CEILING) DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE ;EGGCRATE GRILLE /END CAP /ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL /ELECTRIC END PLUG ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FAHRENHEIT FIRE ALARM CONTRACTOR !FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS. INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE /SMOKE DAMPER FOOT /FEET FUTURE FACE VELOCITY GRILLE GAUGE /GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GRILLE GRILLE /REGISTER /DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER • • HZ IBC ICW ID IE IMC IN IN WG IPLV KW LAT LB /LBS LD /LIN DIFF LF /LIN FT LPG LVG LWA LWG LWR LWT MAX MAU MBH MCA MD MFR MISC MIN MT MTD MUW N/A NC NG /NGAS NIC NO NPCW OA /OSA OB OBD OD P PCF PD PH POC PRESS PSI PSIG QTY R RA RD /RND REF REG REQ'D RF RG RL RPM RS S SA SAT SD S/D SEER SENS SG SL SM SPEC SO SOG SP SOFT SR SS STRUC T TA TEMP TBD TG TOC TOD TOS TOT TSP TSTAT TYP UH UNO V VIAQC VD VEL VERT VFD VOL W WB WG W/ W/O W /SF WSEC HERTZ NTERNATIONAL BUILDING CODE NDUSTRIAL COLD WATER NSIDE DIAMETER /DIMENSION NVERT ELEVATION NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LEAVING AIR TEMPERATURE POUND /POUNDS LINEAR DIFFUSER LINEAL FOOT /FEET LIQUID PROPANE GAS LEAVING SOUND POWER LOW WALL GRILLE LOW WALL REGISTER LEAVING WATER TEMPERATURE MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MANUFACTURER MISCELLANEOUS MINIMUM /MINUTE MOUNT MOUNTED MAKE -UP WATER NOT APPLICABLE NORMALLY CLOSED /NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN /NUMBER NON- POTABLE COLD WATER OUTSIDE AIR OPPOSED BLADE OPPOSED BLADE DAMPER OUTSIDE DIAMETER /DIMENSION PUMP POUNDS PER CUBIC FOOT PRESSURE DROP PHASE POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANITY RETURN GRILLE /RELOCATED /RETURN RETURN AIR ROUND REFERENCE REGISTER REQUIRED RELIEF RETURN GRILLE REFRIGERANT LIQUID REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY SUPPLY AIR SATURATION SMOKE DETECTOR SLIP & DRIVE CONNECTION SEASONAL ENERGY EFFICIENCY RATING SENSIBLE SUPPLY GRILLE SOUND LINED SPIRALMATE /SHEETMETAL . SPECIFICATION SCREENED OPENING SLAB ON GRADE STATIC PRESSURE SQUARE FEET SIDE WALL REGISTER STAINLESS STEEL STRUCTURAL TRANSFER TRANSFER AIR TEMPERATURE/TEMPORARY TO BE DETERMINED TRANSFER GRILLE TOP OF CONCRETE /CURB TOP OF DUCT TOP OF STEEL/TOP OF SLAB TOTAL TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLT VENT. AND INDOOR AIR QUALITY CODE VOLUME DAMPER VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VOLUME WALL/WALLS WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND it 1 • 1Ox10 a lib a 11 10x10 I ,/ 1 • I0x10 0 spy � ROUND DUCT - TURNING UP OR TOWARD r - ZQIr� 10� ‘D . 100 , BOOT TAP 1 ,1114_, f=c=1 1=961 !.INNNNW� '116)111_ SLi 11-6i1-6-fs 150 CEILING SUPPLY AIR DIFFUSER (SHOWN WITH REDIRECTED AIR CORE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE . SLOTTED DIFFUSER (PLAN VIEW) XXO ROUND DUCT SYMBOL XX• FLAT OVAL DUCT SYMBOL XX' DEGREES SYMBOL Ei POINT OF CONNECTION CD1 -100 GRD TAG IDENTIFIER = ;TYPE -CFM 80 SIZE 0 THERMOSTAT/TEMPERATURE SENSOR Q HUMIDITY SENSOR EXISTING DUCTWORK DEMO DUCTWORK 1 a- OMR a-- a - aMR --s ume 1?- cars -- - COM ---; ,_ a -- cows --4 ire 6- OM - CONS -4 RECTANGULAR SUPPLY AIR DUCT - TURNING UP OR TOWARD RECTANGULAR SUPPLY AIR DUCT - TURNING DOWN OR AWAY RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING UP OR TOWARD RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING DOWN OR AWAY ROUND DUCT - TURNING DOWN OR AWAY OVAL DUCT - TURNING UP OR TOWARD OVAL DUCT - TURNING DOWN OR AWAY DUCT OVERLAP 45' TAP VOLUME DAMPER CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES /SPUTTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW DIRECTION FORCED AIR) NR FLOW DIRECTION (DRAWN AIR) MOTOR OPERATED DAMPER FLEX CONNECTION SMOKE DAMPER FIRE DAMPER COMBINATION FIRE & SMOKE DAMPER SOUND TRAP ACCESS DOORS ACOUSTICALLY LINED DUCT (SOUND LINED) DUCT BOARD FABRIC DUCT VAV BOX STATIC PRESSURE SENSOR WALL - MOUNTED GRILLE 0 PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP GAS PRESSURE REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY CHILLED WATER RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY CONDENSER WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN CONDENSATE r _ 1.5 1.5 1.5 1.0 1.0 + 1.5 0.75 1.0 1.0 MECHANICAL GENERAL NOTES 1 . THE 2003 18 N WSEC 2003 IYC 200E ��� AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY ALL P P CONDITIONS, NGEWITHNTA DETAILS, ETC. NOTIFY ENGINEER OF ANY 5. WHEN �� ONT THE ENGINEER VEER PRIOR SIMILAR ROCEEa �UESTIRONS�GW�NOT B THE RESOLVEb DETAILS THIS 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL. CONTRACTOR UNLESS NOTED OTHERWISE. 7. ALL JOINTS IN SUPPLY AND RETURN AIR DUCTS SHALL BE SEALED TO SMACNA C CLASS, OR ABOVE. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT, AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET. 11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OR THE FOLLOWING: A. 0% TO 100% OF THE DESIGN SUPPLY AIR B. CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. C. INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTS AIR WHI�H��bSE L i�1�01+�lAT�ICALLY�WHEN P SYSTEM IS OFF OR POWER fAILUR�E�ZAS REWIRED BY ENERGY CODE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGWWABLE CAPABLE OF BEING SET FOR SEVEN DIFFERENT S�EfP01NT A�HU S�FU4LDLSII�LUDE OF AI BE BETWEEN OF RES��NT DAY � COOLING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SWELL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND BALANCED MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. AL L HVAC SYSTEMS SHALL B aN gTROI E�AND A WRITfEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC c SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL D CERTIFICATE RESULTS OF OCCUPANCY. A COMPLETE E O FINAL COMMISSIONING I NGM B�LAN�CING�RECDRAWINGS AS PER THE WASRHI�TON TO STATE ENERGY CODE. 15. DUCT SYSTEMS SHALL COMPLY WITH MECHANICAL CODES AND SMACNA STANDARDS. DUCTS 28" AND LARGER, WHICH ARE SUSPENDED MORE THEN 12' BELOW STRUCTURAL SYSTEM, SHALL BE EARTHQUAKE BRACED. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEIZMIC HAZARD B. 17. '• O 'E' VIDL AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM PER CODE. OKE DETECTORS SHALL BE FURNISHED AND NSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. POWER-WIRING AND INTERLOCK TO ARE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22. FOR VERTICAL JN SRINSIDE TIGHT" SHAFTS TH HAFT R SHALL THE �F DEDOH A CONTINUO OCCUR: S SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC_) -TOP AND BO WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC) IS WO ACCEPTC�KINEG PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL SEALED N dN NTH SIgEST THE PEHE SHAFT (DUCTWORK, CONDUIT, PIPING....) SHALL BE -USE SECTICN 905 OF THE 2003 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. INSULATE DUCT PER NOTE 11 ABOVE. 24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OVER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 1. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS. 3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS. 4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R -7 FOR REST OF INSTALLATION). 5. R -7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL F: DEDICATED OUTSIDE NR SYSTEM AND LESS THAN 2,800 CFM. MINIMUM PIPE INSULATION (INCHES) LAST UPDATED: , z /o /o INSULATION CONDUCTIVITY SERVICE HWS&R HWS&R CMMSdcR FLUID TEMP 'F 1 41 -200 105 -140 40 -45 CHWS&R <40 0.23 -0.27 75 1.0 1.0 CWS&R 40 -45 0.23 -0.27 75 0.5 0.5 CONDENSER WATER (FOR NON - ECONOMIZER SYSTEMS - INSULATION IS NOT REQUIRED CONDUCTIVITY RANGE 0.25 -0.29 0.24 -0.28 0.23 -0.27 • MEAN TEMP RATING 'F 125 100 75 RUN -OUTS UP TO 2 0.5 0.5 0 0.5 NOMINAL PIPE DIAMETER (IN) 4 5ftni 0 12, . I . • APN NUMBER 2623049143 LEGAL DESCRIPTION BOA 143 LOT 3 OF CITY OF 1UKMALJI SHORT PLAT NO 1.97-0019 RECORDING NO 871101A0018AID SHORT PLAT DEFIED - PORTION OF E 112 OF NYV 114 OF SE 1M, BEGIN NE CORNER OF SAID E 1R BEING N 11-05-42 W 1339.34 FT FROM NE CORNER OF SE 111TH S 01J7,29 W 1322.34 FT TO SOUTHEAST CORNER 1Fi N E74612 MI169.36 FT TO W LINE OF E 16934 PT OF SAID E 1R ?H N 014749 E 10.30 FT TO N IJNE OF SAID E 1R TH S !A-05-42 E 659.31 FT TO POB LESS PORTION FOR 59T11 AVE SOUTH LESS PORTIONS FOR STREETS AS CONVEYED BY DEED, RECORDING NO 7907120710 LESS • PORTION CONVEYED TO CITY OF TUKYNLA FOR ROAD BY DEED, RECORDING NO 4408290.127 7035 M,oQunt corn (40//n& fly of bats BUILDING DIVISION . Capoaatc rf'V C xvxMe a 3 j .- . t es W+w , Evans Bieck Or BLS COPY No. Aiii5 .1)82„ avow r subject merrors and =Wow construction documents doss not auaiati. d MOM ads or ordinance. Wipt melons Is scloiarMOPd: SITE MAP NO SCALE r.. •• • . ,q Blvd A 1 11E PERMIT POR; VICINITY MAP ""' I � NO SCALE Pliong j PCITE: Reviskxis WI !squint a new pin submittal and may Include additional plan review feu. lb ch ewe shell be reeds to the awe of work without prior approval et Tubas ibrikiing Division. 7Lkwla DDQSION NICE1VED CITY OF TUKWiLA MAY 3 12N5 PERMIT CENTER ISSUE FOR PERMIT • Hermanson 1?2 l�rn�oiron�Ca� y UP Norlh Knit, Washington 980332 Tel (208) 57S- -97+00 Fax. (20S) 575 -98cm www herm•nson.con, Contactor Rog HEAWCUXIMIJ IAD+T TI C.E.0 Boiling 7 Floor 2 655 Andover Park West Tukwila, WA I MIRES ,/z./ ob Revisions LJ_ __ REVIEWED ..� JUN - 120(6 Of Tukwila 5/27/05 KB ISSUE FOR PERMIT No. Dots Description Design Team Design KB Drown ER Checked KB Scale AS NOTED Drowinq Number C- 0045 -g7$ Project Number 10 -5-278 Issue Dote 5127/05 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M0.00 MOSQ - Ii 4 44f) Hermanson Honnorson Company UP Inl 2nd hems North KM+t, Woolinton 950312 Tel (206) 575 -9700 Fax (206) 575 -9600 VANN hennenson COT Contractor Rog 9: HE1111a005I IAD+TTI C.E.0 Building 7 Floor 2 . 655 Andover Park West Tukwila, WA ; \)• 1 • • � R 1 ,, ' -1 lt' . -, t \ .J • AL , 1 DAMS 1/29" � Revisions 5/27/05 KB ISSUE FOR PERMIT it o. Dote By Description Design Team Design KB Drown ER Checked KB Scale AS NOTED Drow;n9 Number C- 0045 - 278 Project Number 10- 5--278 Issue Date 5/27105 SECOND FLOOR PLAN & SCHEDULES - HVAC M2.02 • KNEW PAIL . REMOVE DUCT 11 1111 3 11 r • 1 NEU aye • OM WO i11111..11111.• MEIMMINIEMMI i •••••■FiRieMMILIIM • Illeireenzenermann uuuauuuuuauuaaui Immosimiummounw 111111111111111111111111111111111 111111111 II I a� ■ ■ ■ ■ ■ ■1 t ■t I I. I 1 ua.uuuuauiiio I 1 IJRR i uu•F � �I aw uuuuui 1 u1a1 i .muur aiivauuu111► i a.rnuu, aauue i uuaiu 180 NIL uuuuS It iRuL t llio EN • Er Ilan i 36 SE Al ClURI 49 el ASSR # Li-o7_51 • • Mallill lit CORRIDOR CIF IMINIMINIII willitit 202 204 iiiNENffiliiiiiMilialiihn - in ............iii: ,mi monmamminwom inell01111111111111111111•Minn11111 a Oa , N11111111111111111111111111111111111111" 1111112- 11.111111111111111111111111111E1111111111101 owe /I i ■aitii�iiari Dr • tUiIURIRiUUiL_ 111111111111111111111111111111111111111111i it.:4 imumuramrs " 1111 SERIMINIMIIIIIP IdLI e Y&N.Air 3CI ZTURE COMPUTER LAB O - MUM MIND MIND MIND M - IM - MOM•MMI= OMB MN= AMID A I . OMR • CLASSROOM I 211 OMR - -- ---- -- I /MI , - M • - M , - - e CAP REMOVE DUCT C I I I I 1 I SEWONG LAB I I I I I I I I I I 1 I r , I 1 AREA OF WORK SCALE: 1/8 = 1' -0' • • SECOND FLOOR PLAN - HVAC REMARKS 1 2 3 4 5 6 7 6 DISCONNECT BY ELECTRICAL SERIES FM POWERED TERMINAL UNIT WITH HEAT - SIZE AS LISTED, PRESSURE INDEPENDENT, FACTORY OPTIONS INCLUDE: •- EXTENDED DAMPER 1/2 DIVA. SWJ T - FACTORY INSTALLED 1' THROW -AWAY FLIERS - UNIT CONTROLS AND AUTO RESET 130 DEG. F. THERMOSTAT BY CONTROLS CONTRACTOR -- MATT LNER FACED I TERNAL INSULATION TO M RSTREIM - MARE SPEED FAN CONTROL - 24V TRANSFORMER, 50 VA MIN RATING - HEAT STAGING & FIN CONTROL THROUGH FACTORY WIRED RELAYS 460V/3PH TERMINAL UNITS REQUIRE A FOUR WIRE POWER FEED IN ORDER TO SUPPLY 277V/1 PH POWER TO THE FAN MOTOR INE111 VAV BOX. PROVIDE NEW 7 -DAY PROGRAMMABLE T -STAT EXISTING VAV BOX. REBALANCE ONLY EXISTING via RELOCATED AS SHOWN ON DRAINi1NGS ANO REBAUNCED EXISTING VIW BOX NOT M SCOPE OF WORK EXISTING WM BOX. SET AT LOW SPEED AND REBP1ANCE ..•Dt31-.,. CONSTRUCTION NOTE$: LI)RELOCATE TERMINAL UNIT INTO SEWING lA6 TO ACCOMMODATE NEW TENANT LAYOUT 0 RELOCATE TERMINAL UNIT INTO SEWING LAB TO ACCOMMODATE NEW TENANT LAYOUT 0 DEMO SECTION OF 180 AND 120 ROUND MEDIUM PRESSURE DUCT AS SHOWN AND REPLACE WITH NEW 260 AND 220. 0 RELOCATE DIFFUSER SOUTH INTO NEW COMPUTER LAB O RELOCATE DIFFUSER WEST INTO NEW COMPUTER LAB 0 CONNECT DIFFUSER TO NEW TERMINAL UNIT Q7 RELOCATE DIFFUSER EAST INTO SEWING LAB 0 NEW DIFFUSER 0 RELOCATE T-STAT SOUTH WEST INTO NEW COMPUTER LAB 10 RELOCATE TERMINAL UNIT NORTH EAST INTO SEWING LAB TO ACCOMMODATE NEW TENANT LAYOUT 11 RELOCATE T-STAT TO EAST WALL OF SEWING LAB 12 RECONNECT DUCTWORK TO TERMINAL UNIT 210 13 RELOCATE RETURN GRILLE WEST INTO NEW LECTURE CLASSROOM 14 RELOCATE RETURN GRILLE SOUTH INTO COMPUTER LAB 15 REBALANCE TERMINAL UNIT AND DIFFUSERS IN EXISTING TENANT AREA 16 RELOCATE RETURN GRILLE EAST INTO NEW SEWING LAB 17 SET SUPPLY AIR TEMPERATURE AT ROOF TOP UNIT TO 55F MIN 18 RELOCATE RETURN GRILLE SOUTH INTO LECTURE CLASSROOM 19 RELOCATE DIFFUSER NORTH INTO EXISTING TENANT AREA 20 REMOVE TRANSFER GRILLES r 4 TERMINAL UNIT SCHEDULE - ELECTRIC LAST UPDATED: 5/19/05 TAG LOCATION AREA VAV -201 , BLDG 7, FIR 2 VAV -202 BLDG 7, FIR 2 EXIST. Oita EXIST. OFFICE VAV -203 BLDG 7, FIR 2 EXIST. OFFICE VAV -204 BLDG 7. FIR 2 EXIST. OFFICE VAV -205 BLDG 7. FIR 2 cast. OFFICE VAV -206 BLDG 7. FLR 2 SEWING UB VAV -207 BLDG 7, FIR 2 EXIST. OFFICE VAV -208 BLDG 7, FIR 2 COMPUTER LAB VAV -209 BLDG 7. FIR 2 SEWING U18 VAV -210 BLDG 7, FIR 2 SEWING 1118 VAV -211 , BLDG 7, FIR 2 COMPUTER LIIB VAV -212 BLDG 7, FIR 2 SEWING LAB VAV -219 BLDG 7. Fla 2 lsCnlns ores BASIS OF DESIGN INDUCTO H*S1500 I NDUCTO REDDI VEUCTO INDUCTO TUTUS NOV waUcTO ►ss2000 TITUS MY REDDI NNDUCTO TITUS PMFV ToMPwsTER INVIROTIC MA 1490 NUT Duk FMI CFM IUII IRAN CFM N1 1,600 NA NA 1,500 , N► 1,200 C NA r N11 600 NA NA NA 10 840 200 1,755 440 1,000 270 NA 10 NA 180 12 990 NA 90 1,090 1.000 900 1.600 NA 8'ro 14 470 _ •4 FAN MOTOR HP NA • NA V/PH NA NA NA NA NA ELECTRIC HEATING Coll Cal 1500 1200 600 400 1600 I NA NA 840 NA NA 1755 NA NA , 1080 NA NA 180 ANA NA 1080 NA NA 1080 NA NA 1/2 277/1 f 1 o TEMP. RISE T 35.7 34.1 26.2 39.4 35.0 49.5 11.7 43.7 18.9 KW 17.0 13.0 5.0 22.0 2.0 17.0 4.0 5.0 9.0 NO. OF sr*;ES NA NA NA NA NA NA NA NA NA NA NA NA 2 V/PH R WRKS 7 7 277/1 A 7 5 7 5 480/3 I 8 6 277/1 6 480/3 6 277/1 I 5 277/1 5 4&J /3 1.2,9.4 PECENED cv OF TUKWILA MAY 3 1 2115 IERMTT CENTER ISSUE FOR PERMIT