Loading...
HomeMy WebLinkAboutPermit M05-112 - GENERAL BUILDERS SUPPLYGENERAL BUILDERS SUPPLY Parcel No.: Address: Suite No: City CTukwila 0223200040 510 STRANDER BL TUKW Tenant: Name: GENERAL BUILDERS SUPPLY Address: 510 STRANDER BL, TUKWILA WA Owner: Name: 7 & R INVESTMENTS Address: PO BOX 30089, PORTLAND OR Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.wa.us Contact Person: Name: 3OHN COLLUM Address: 4210 'B' STREET NW, SUITE F, AUBURN, WA Contractor: Name: FIVE STAR MECHANICAL Address: 3902 W VALLEY HY STE 200, AUBURN WA Contractor License No: FIVESM *010JT MECHANICAL PERMIT DESCRIPTION OF WORK: REMOVE 2 EXISTING PACKAGED ROOF TOP HEAT PUMPS ANDREPLACE THE SAME WITH 2 ROOF TOP PACKAGED GAS ELECTRIC UNITS. WORK WOULD ALSO INCLUDE GAS PIPING FROM THE EXISTING METER TO THE NEW UNITS. INSTALL 2 NEW THERMOSTATS. Value of Mechanical: $16,000.00 Fees Collected: $338.73 Type of Fire Protection: NONE International Mechanical Code Edition: 2003 Furnace: <100K BTU 2 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 2 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC- Permit EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -112 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 - 852 -8284 Phone: 253 - 833 -8284 Expiration Date:04 /30/2006 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -112 08/09/2005 02/05/2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 08 -09 -2005 re J U 0 0 0 . cn w . w O 2 u- Q. Y2 d uj } Z I— O Z H. w uj D 0 Y4 0 w u. �: Iii Z O 1— Z Permit Center Authorized Signature: max I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: �`-- ' Date: E-9 _C5 Print Name: \J -- C -3 1/11 1 1 ao ∎ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC- Permit City o: Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.wa.us M05 -112 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -112 Issue Date: 08/09/2005 Permit Expires On: 02/05/2006 Date: 6 -0t- Printed: 08 -09 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223200040 Address: 510 STRANDER BL TUKW Suite No: Tenant: GENERAL BUILDERS SUPPLY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: M05 -112 Status: ISSUED Applied Date: 07/29/2005 Issue Date: 08/09/2005 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M05 -112 Printed: 08 -09 -2005 1 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. Signature: (\ Date: 8 -05 Print Name: V C� v� t^ eD l 1 U . VV\ of law and ordinances other work or local laws doc: Conditions M05 -112 Printed: 08 -09 -2005 N CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 SITE LOCATION Site Address: enra lltlrl s p P New Tenant: ❑ Yes Tenant Name: Property Owners Name: ntler .S ou cl e. Mailing Address: - —' +h r 'CONTACT . PERSON Name: R CV )rn l,Jil Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** ) n nrl Pr . Contact Person: E -Mail Address: q:Vermito phiaiec elmapepartait application (1 - Rrvin& 6-8-03 ne Pago 1 Building Permit No. Mechanical Permit No. Mb 5 -112, Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 1722 — Suite Number: Floor: State State State State State Zip Zip Zip Zip Zip ErNo Day Telephone: AU-, - a H 3 to_ Mailing Address: City E -Mail Address: Fax Number: GENERAL CONTRACTOR INFORMATION - (Mecha.ical Contractor inforiaation on back page) Company Name: Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD - All smut be Wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: ENGINEER OF RECORD —.All plans rut be wet star.ped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: 1 Unit Type: Qtv Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty FurnaceK100K BTU Air Handling Unit >10.000 CFM Fire Damper 0-3 HP/100.000 BTU Furnace >•100K BTU Evaporator Cooler Diffuser 3 -15 HP /500.000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat , O� 15 -30 HP/1.000.000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood'Gas Stove 30-50 HP/1.750.000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1.750.000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10.000 CFM a Incinerator -Comm Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTIOr INFORMATION , FINE. Company Name: s r 1 t OR 1 ec nut Mailing Address: City state Zip Contact Person: a h n CO 11. m Day Telephone: (9F A "Ra 8 E -Mail Address: C01111 m °e I�l rr�l(ch ., CC) n Fax Number: elF�- CL - &lets Contractor Registration Number: r 1 NI ESM *0) QT1 Expiration Date: `4 - 30 " aCX * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ • ell O0 Scope of Work (please provide detailed information): • 11 b •. ` / • f_ heet+ pumps replace - hc _same_ Vs hhh c rti 4c p el e� - roc. i nits, nrk iuotilri aLso Inc l de s i r7 \ � p Date Application Accepted: q -)7 y:Namity *Aim dw..rpnmie salcs60. (7-2004) R.vird 68-03 bh BUI ' ' ER OR AUTHORIZED AGENT: Si Print Name. S7SO n l 11U m Mailing Address:Hal(f M . NW tl l Page 4 Indicate type of mechanical work being installed and the quantity below: L 4 Wks Ca• Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... Fuel Type: Electric l7 Gas.... Other: PERMIT APPLICATION N OTES - Applicable to all pen nits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Espiratien of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date:7 - aP) - O Day Telephone: & &:2)" -PF Ea8 ubti rr 1nIlA c1 city state Zip Date Application Expires: G7 - 'lam' Staff itials: 1 4 re 2 Parcel No.: 0223200040 Permit Number: M05 -112 0 a Address: 510 STRANDER BL TUKW Status: APPROVED N 0 Suite No: Applied Date: 07/29/2005 co W Applicant: GENERAL BUILDERS SUPPLY Issue Date: N uj O Receipt No.: R05 -01171 Payment Amount: 276.98 u. Initials: BLH Payment Date: 08/09/2005 10:48 AM W User ID: ADMIN Balance: $0.00 , z zo D0 O N 0 I— Payee: TRANSACTION LIST: w 0 � U Type Method Description Amount LL O, Payment Check 26317 276.98 111 U o z ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 FIVE STAR MECHANICAL MECHANICAL - NONRES RECEIPT Account Code Current Pmts 000/322.100 276.98 Total: 276.98 5952 08/09 9716 TOTAL 276.98 Printed: 08 -09 -2005 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: City of Tukwila TRANSACTION LIST: Type Method ACCOUNT ITEM LIST: Description doc: Receipt 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0223200040 510 STRANDER BL TUKW GENERAL BUILDERS SUPPLY R05 -01125 BLH ADMIN FIVE STAR MECHANICAL Payment Check PLAN CHECK - NONRES Description 26277 RECEIPT Account Code 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 61.75 Current Pmts 61.75 Total: 61.75 M05 -112 PENDING 07/29/2005 61.75 07/29/2005 01:19 PM $276.98 5541 07/29 9716 TOTAL 61.75 Printed: 07 -29 -2005 Project: c,W7 1 � / 4?/r, As Type of Inspection: ,'7V / Address: 570 , 5 7/74it// � W •dt. Date Called: ,/ -2v- e‘ Special Instructions: ""Y,. Date Wanted: v m p.m. Requester: 732o) 7,:e ‘ — 52.8 2 INSPECTION RECORD Retain a copy with permit CTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.r40 00, Tukwila, WA 98188 a Approved per applicable codes. gi Corrections required prior to approval. COMMENTS: Inspector: Date:/..... 3 4 .00 REINSPECTION FE REQUIRED. Prior �,6 inspection, fee must be id at 6300 Southcenter B d., Suite 100. I1 to sechedule reinspection. eipt No.: (Date: Pro e f ct ivHey9../ / Type of In 01//iirriA17-eir e&Apeci Address: -1-/e) -5 4' 1_ Date Called: / / / 30/ Special Instructions: Date Wanted: i //2// rne Requester: Pifone No: \ . I Do-6 06'4 62_ r INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 IT NiO 1 (2 ' 06)411-367 Corrections required prior to approval. COMMENTS: A/J S — /6- s-c-1.,c(?(& Date: - /- $ .00 REINSPECTIOd FEE EQUIRED. Prior cl at 6300 Southcenter BL 4L, Suite 100. I Rec ipt No.: inspection, fee must be U to sechedule reinspection. 'Date: Approved per applicable codes. File: M05 -0112 5mm Drawing #1 TerraServer Image Courtesy of the USGS Send To Printer Back To TerraServer Change to 11x17 Print Size Show Grid Lines MUSGS Tukwila, Washin.ton, United States 13 Jun 2002 Or 1 25 m Or ' 1 25 yd Image courtesy of the U.S. Geological Survey © 2004 Microsoft Corporation. Terms of Use Privacy Statement Change to Landscape http: / /terraserver. microsoft. com/ PrintImage.aspx ?T= 4 &S= 8 &Z =10 &X= 11132 &Y = 10512„ . Page 1 of 1 7/28/2005 07/29/05 FRI 11;08 FAX 253 820 8214 , the Crane Company, 1;Ater Products Group Tyler texas 75711 A C-• MODEL, RATED VOLTS /PH. /HZ. -~ RATING COOLING (1) BTUH Airflow Indoor (CPM) System Power (KW 4 E.E.R. /S.F E.H.) Noise Rating No. (2) RATING HEATING (1) (High Temp) BTUH System Power (KW & C.O.P.) (Low Temp.) STUN System Power (KW & C.O.P.) H.S.P.F. (BTU /wall -hr.) (6) POWER CONNECTIONS Min. Br. Cir. Ampacily (Amps) (3) Br. Cir. Prot. Rig. Max & Recm d. (Amps.) COMPRESSOR Volts /Ph. /Hz. R.L. Amps Branch Cir. Select. Cur. Amps L.H. Amps OUTDOOR COIL -- TYPE How;; /F.P,I. Alen - (:+1 Fr 1 Tube size (Ill.) Refrigerant Control INDOOR COIL -- TYPE Drain Conn. Size 611.) Duct Gunn -- Supply (in.) Duct. Conn. •.•- Return (in.) OUTDOOR FAN -- TYPE Dia. (in.) No, Used Drive /5peeo (No ) CFM (4) Motor H.P. --- Speed (RPM) Volts /PII. /Hz. I .L. Amps rtNDOOR FAN -- TYPE Dia. /Width (in.) Na. Used Drive /Speeds (No.) CFM vs. in w.g. (5) Motor H.P. - Speed (RPM) Volts /Ph. /Hz. F.L. Amps FIM.TER (Not Furnished) Type Recommended No. /Size (in.) Recommended REFRIGERANT Charge (lbs. of R -22) DIMENSIONS Crated (in.) Uncraled - Detail (in.) %RIGHT Shipping (lbs.) Net (tbs.) SINGLE PACKAGE 1 1) Rated in accordance with A.R.I. Standard 240. (2) Rated in accordance with A.R.I. Standard 270. 4.94 4.08 r( BWCO42DIQ0• 230/1 /60 44,000 1,400 5.38 8.20/8.60 46.500 2.75 25,000 1.80 6.05 230 /1/60 33 50 - 50 ClimatuU 230/1/60 20.0 21.8 103 Plain Fn 4 / 1.`•! 3/8 Copper Expansion Valve f'l'ute Fm Propeller 16 2 Direr) /Single 3750 1/4 --- 1600 230/1/60 1,2 Centrifugal 11.0 x 9.5 Direct / 3 1/2 •-- 1075 230/1 /60 3.0 1" Throwaway 2 - 16 x 25 11 lbs. 12 oz. 563 H I W � 37 57 -3/4 48 551 GENSCO /TRANE PRODUCT SPECIFICATIONS BWC042D30011 SWC042D400H 200/230/3/60 460/3/60 44,000 1,400 5.38 8,20/8.60 6.6 8.6 46.500 4.94 2.75 25,000 4.08 1.80 6.05 200/230/3/00 24 35 - 35 Clirnatulti 200/230/3/60 14.3 14.3 100 PI;Ite Fin 1 / 12 3/8 Copper Expansion Valve Plate Fin 31.1 WI' SEE OUTLINE, DRAWINGS SEE OUTLINE DRAWINGS Propeller 16 2 DirecI/Sinyle 3750 1/4 - 1600 200/230/3/60 1.2 Centrifugal t1,D 1 Direct / 3 SEE FAN PERFORMANCE 1/2 - 1075 200/230/1/60 3.4 1" Throwaway 2 .--16 x 25 4 DATA SUBJECT TO CHANGE WITHOUT NOTICE 11 lbs. 12 oz. H W 1 D 37 ' 57 -3/4 48 37 SEE OUTLINE DRAWINGS 563 551 5.38 4.94 4.08 (3) Calculated in accordance with currently prevailing National Electric Code. Suitable for use with HACR circuit breakers or fuses. (4) Std. Air Dry Coil Outdoor (5) Std. Air Wel Coil Indoor (6) Rated in accordance with D.O.E. test procedure. H.S.P.F is at the minimum design requirement for Region IV. 44,000 1.400 8.6 46,500 25,000 6.05 460/3/60 12 15 - -15 ClimatuIf 460/3/80 6.4 0.4 8.20/8.60 2.75 1.80 47 Plale Fin 4 /12 3/8 Copper Expansion Valve Plain Fin :1/4 NF'f Propeller - 16 2 Dir^ci/ Siu'iIC 3%50 3/4 --• 1600 4601,11.60 C(SO • ri Zfr 1/2 -1071 1, 10 2.0 1" Throwaw W 0 57 -3/4 48 563 561 rib 002 00 a rl RTPRC006•EN Y5coM8R4 11 Table GD-1 - General Data Cooling Performance' Gross Cooling Capacity SEER' Nominal CFM /ARI Rated CFM MI Net Cooling Capacity System Power (KW) Heating Performance' Heating Models Heating Input (Btu) Heating Output(Btu) AFUE % Steady State Efficiency (%) No. Bumers No. Stages Gas Supply Line Pressure Natural (minimum/maximum) LP (minimum/mEocimum) Gas Connection Pipe Size (in.) 1/2 Compressor No/Type Outdoor Sound Rating (dBW Outdoor Coil -Type Tube Size (in.) OD Face Area (sq ft) Rows/FPI Indoor Coil -Type Tube Size (in.) Face Area (sq ft) Rows/FPI Refrigerant Control Drain Connection No/Size (in.) Outdoor Fan -Type No. Used/Diameter (in.) DriveTyperNo. Speeds No. Motors/HP Motor RPM Direct Drive Indoor Fen -Type No. Used/Diameter (in.) DriveType No. Speeds No. Motors Motor HP (Standard/Oversized) Motor RPM (Standard/Oversized) Motor Frame Size (Standard/Oversized) Low 60,000 47,000 80 80 2 1 1/Climatuff General Data 3 Ton Convertible Units YS0036A1 YSCO36A3, A4, AW 37,400 10.5 1,200/1,200 36,000 3.91 Medium 80,000 63,000 80 80 2 1 flgh 120,000 95,000 80 80 3 1 4.5/14.0 10.0/14.0 1/2 1/2 Hermetic 83 Lanced 0.3125 7.19 2/17 Lanced 0.3125 5.67 2/16 Short Orifice 1/ NPT Propeller 1/22 Direct/1 2,550 1/0.20 1,075 FC Centrifugal 1/10 x 10 Direct/2 1 0.33/0.50 950/1,100 48/48 Low 60,000 48,000 81 81 2 1 37,400 10.7 1,200/1,200 36,000 3.79 Medium High 80,000 120,000 64,000 96,000 81 81 81 81 2 3 1 1 4.5/14.0 10.0/14.0 1/2 1/2 1/2 1/Climatuff Hermetic 83 Lanced 0.3125 7.19 2/17 Lanced 0.3125 5.67 2/16 Short Orifice 1/ NPT Propeller 1/22 Direct/1 2,550 1/0.20 1,075 FC Centrifugal 1/10 x 10 Direct/2 1 0.33/0.50 930/1,100 48/48 MANE' (3 - 4Tons) Standard Efficiency 4Ton Convertible Units YSC048A1 YSC048A3, A4, AW 50,300 10.1 1,600/1,600 48,000 5.28 49,200 10.0 1,600/1,600 47,000 5.40 Low Medium High Lav Medium High 60,000 80,000 120,000 60,000 80,000 120,000 47,000 63 ,000 95,000 48,000 64,000 96,000 80 80 80 81 81 81 80 80 80 81 81 81 2 2 3 2 2 3 1 1 1 1 1 1 4.5/14.0 4.5/14.0 10.0/14.0 10.0/14.0 1/2 1/2 1/2 1/2 1/2 1/2 1 /Climatuff Scroll 1 /Climatuff Scroll 86 82 Lanced Lanced 0.3125 0.3125 6.17 9.59 2/17 1/17 Lanced Lanced 0.3125 .3125 6.68 6.17 3/16 3/16 Short Orifice Short Orifice 1/ NPT 1/ NPT Propeller Propeller 1/22 122 Directll Direct/1 2,850 3,610 1/0.33 1/0.33 1,075 1,075 FC Centrifugal FC Centrifugal 1/11 x 11 1/11 x 11 Direct/2 Direct/2 1 1 0.60 /0.80 0.60/0.80 1,000/1,100 1,000/1,100 48/48 48/48 RECEIVED errs OF TUKVVII• JUL 2 PERMIT CEN'I'E'' 1 z 00 ta N W U) LL; W 0 I -J N a : =W I- i Z �. o 1 W H . ui D O - 0 I - HU U. I W U = O ~ 2 MAW' Table GD-1 — Continued General Data (3 - 4Tons) Standard Efficiency 3Ton Convertible Units 4Ton Convertible Units YSCO36A1 YSCO36A3, A4, AW YS0048A1 YSC048A3, A4, AW Belt Drive Indoor Fan -Type — FC Centrifugal — No. Used/Diameter (in.) 1/11 x 11 — 1/11 x 11 DriveType/No. Speeds — BeltNariable Sheave — No. Motors — 1 — 1 Motor HP ( Standard/Oversized) — 1.00/— — 1.00/— Motor RPM ( Standard/Oversized) — 1,750/— — 1,750/ — Motor Frame Size (Standard/Oversized) — 56/— _ 56/_ Fitters -Type Furnished n Throwaway Throwaway Throwaway Throwaway (No.) Sue Recommended (2) 20 x 25 x1° (2) 20 x 25 x1° (2) 20 x 25 x1 (2) 20 x 25 x 1° Refrigerant charge (Lbs of R -221 3.8 3.8 4.4 3.8 Notes: 1. Cooling Performance is rated at 95 F ambient. B0 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air- Conditioner Equipment certification program. which is basedon ARI Standard 210/240 except AK (380V/60 Hz). 2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. a Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or360. Units are rated at 80° F ambient, 80 F entering dry bulb, and 67° F entering wet bulb at ARI rated cfm. 4. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. 5. AFUE is rated in accordance with DOE test procedures. 6. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table PD-90. 7. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 9 20 x 25 filter on medium and low heat models. 20 x 30 filter on high heat models 9. Motor RPM shown is low speed. High speed RPM is 1.060/1,145. 10 Optional 2" pleated filters also available. 16 OffeallanalelMISMMISONESEIMM RECEIVED CITY OF TUKWILA ti I. 2 9 '2i 5 PERMIT CENTER • RT PRC W 6 0 0 CO 0 N W •: W 0 ,. g J. co 3 UJ Z Z O W Lij 0 0 0 -, W W: V : U. O ' Z 0 t • t TRINE' Table W -1 — Maximum Unit And Comer Weights (Lbs) And Center Of Gravity Dimensions (In.) Unit Maximum Weights (Lbs)' CornerWeights (Lbs)' Center of Gravity (In.) Tors Model No. Shipping Net A B C D Length Width 3 YSCO36A 572 480 151 124 96 109 32 19 YHCO36A 589 497 158 128 101 110 32 19 YSC048A 597 505 159 130 108 109 33 19 YHC048A 631 539 166 133 114 126 32 20 5 YSC060A 614 522 169 134 105 114 32 18 VHC060F1 666 574 179 140 119 136 32 20 6 YSC072A 878 735 249 193 132 161 39 21 YHO372A 915 772 249 198 141 184 39 22 YSC090A 963 820 273 208 146 193 38 22 7'/2 YSC092A 965 822 277 222 147 175 40 21 YHO092A 1066 923 306 243 166 210 39 22 81/2 YSC102A 1042 899 297 243 165 194 40 21 YHC102A 1100 957 310 252 175 220 40 22 10 YSC120A YHC120A -i1 Notes: 1. Corner weights are given for information only. 2. Weights are approximate. 1063 1203 Weights t 958 1060 CENTER OF GRAVITY WIDTH D CENTER OF GRAVITY 317 342 CENTER OF GRAVITY f LENGTH --o- 261 ► 261 277 177 197 202 245 41 21 40 22 RECEIVED CITY OF TUKWILA JUL 2 9 21f5 PERMIT CENTER Table W2 — Factory-installed Options Net Weights (Lbs) Net Weight 3-5Tons 6- 1OTons 26 36 Accessory Economizer Barometric Relief 7 10 Powered Exhaust — 80 Motorized Outside Air Damper 20 Manual Outside Air Damper 16 Roof Curb 70 Oversized Motor 5 Belt Drive Motor 31 Smoke Detector, Return 7 Smoke Detector, Supply 5 Coil Guards 12 Hinged Doors 10 Powered Convenience Outlet 38 Through the Base Electrical 8 Through the Base Gas 5 Unit Mounted Circuit Breaker 5 Unit Mounted Disconnect 5 Novar Control 8 Dehumidification (Hot Gas Reheat) Coil 15 Notes: 1.Weights for options not listed are < 5 tbs. 2.Net weight should be added to unit weight when ordering factory- installed accessories. 30 26 115 8 7 5 20 12 38 13 5 5 5 8 25 07/29/05 FRI 11:07 FAX 253 820 8214 PRODUCT DATA •••••■••., The Trane Company, Deafer Products Group, Tyler, Texas 75711 MODEL RATED VOLTS /PH. /H2. RATING COOLING (1) DTUH Airflow Indoor (CFM) System Power (KW & E.E.R. /S.E.E.R.) Noise Rating No. (2) RATING HEA1tING (1) (High Temp) RTUH System Power (KW & C.O.P.) (Low Temp.) 6TUH System Power (KW it C.O.P.) H.S.P.F. (8TU /watt-hr.) (6) POWER CONNECTIONS Min, Br. Cif, Ampacity (Amps) (3) Br. Cir. Prot. Rtg. Max. & Recm'd. (Amps.) COMPRESSOR Vdls /Ph. /Hz. R.L. Amps Brandt Or, Select. Cur. Amps L.R. Amps OUTDOOR COIL -- TYPE Rows /F.P.I. Face Area (Sq. FL) rube - size (in.) Refrigerant Control 174000R COIL - TYPE Row, /F,P.I. Face Area - (Sq. F1.) Tube - size (in.) Refrigerant Control Drain Conn. Size (in.) Duct Cnnn. - Supply tin.) Biro. Cnnn. - Rolurn (in.) CFM (4) Motor I LP. - Speed (RPM) Von; /Ph.; I tz. F 1 '.Inn• I?: )C Oi FAN .- TYPE Oia. /Width (in.) No. used I:ivu /Spi.cd: (No.) CFM vs. in w.g. (5) Motor H.P. - Speed (RPM) Volts /Ph, /Hz. F L. Amps FILTER (Not Furnished) Type1?egentended No. /Size (in.) Recommended REFRIGERANT Charge (tbs. of 8 -22) DIMENSIONS Crated (in.) Uncrated -- Detail (in.) WEIGHT Shipping (IbsJ Net (lbs.) (1) Rated in accordance with (2) Rated in accordance with 6 SINGLE PACKAGE GENSCO /TRANE PRODUCT SPECIFICATIONS BW00e01)1004 8wc0600300H 230/1/60 -- 200/230/3/60 A.R.I. Standard 240. A.R.I. Standard 270. 56,000 2,000 7.00 8.00/8.70 8.6 6.32 5.00 59,000 2.75 1,80 6.30 230V. 44 70 - 70 31,000 Climatultw 230/1 /60 27 29.5 146 Plate fin 5/12 8.37 3/8 Copper Expansion Valve Plate Fin 4 / 12 5.49 3/8 Copper Expansion Valve 3/4 NPT 3400 1/4 - 1600 730/1/60 1.2 Centrifugal 11,8x9.5 Direct / 3 3/4 - 1075 230/1/60 4.4 1" Throwaway 2 -.• 16 x 25 13 lbs. 6 oz. 317 57- 592 580 0 48 56,000 2,000 7,00 8.00/8.70 8.8 59,000 6.32 2.75 31,000 5,00 1.80 6,30 200 -230V. 32 50--50 CIimatuflTM' 200/230/3/60 19,5 19.5 125 Plate Fin 5/12 13.37 3 /t1 Copper Expansion Valve Plate Fin 4 / 12 5.49 3/8 Copper Expansion Valve 3/4 NPT SEE OUTUNE DRAWINGS SEC OUTLINE DRAWINGS 3400 1/4 -1600 200/230/1/60 1.2 ~ ~� • Centrifugal ._.._ 11.8 x 9.5 Direct / 3 SEE FAN PERFORMANCE 3/4 -- 1075 200/230/1 /60 5.5 1" Throwaway 2 -16x25 13 lbs. 6 oz. 37 57-3/4 ( 48 SEE OUTLINE DRAWINGS 592 580 (3) Calculated in accordance with currently prevailing National E ectric Code. Suitable for use with HACK circuit breakers or fuses. (4) Std. Air -.- Dry Coil Outdoor (5) Std. Air Wet Coil indoor (6) Rated in accordance with 0.0.E. test procedure. H. is at the minimum design requirement for Region IV. DATA SUBJECT TO CNANGF WITHOUT NOTICE H 37 BW 0800400H 460/3/60 56,000 2,000 7.00 8.00 /8.70 13.8 59,000 8.32 2.75 31,000 5.00 1.80 6.30 460V. 15 20 --- 20 Climatuffw 460/3/60 8.5 8.5 51 Plate Fin 5 / 12 8.37 3/6 Copper Expansion Valve Plate Fin 1 / 12 5.49 3/B Copper Expansion Valve 3/4 NPT Ii 003 3400 114 . •_ 1600 460 /I /GO fl Centrifugal ~ _ 11.8 x 9.5 1 Direct / 3/4 1075 460/1/60 2.5 • 1" Throwaway 2 - 1625 13 lbs. 6 oz. w 57.3/4 592 580 0 48 RECE1V'>~o o i rri OF11t'•` U S.P.FJ V L 2 �f nti5 PERM{') w-i;d+)'GF • Table GD-2 — General Data Cooling Perfvnum oe Gross Cooling Capacity SEER/EER Nominal CFM /ARI Rated CFM ARI Net Cooling Capacity Integrated Part Load Value System Power (KW) Heating Performance' Heating Models Heating Input (Btu) Heating Output (Btu) AFUE % Steady State Efficiency ( %) No. Bumers No. Stages Gas Supply Line Pressure Natural (minimum/maximum) LP (minimum/maximum) Gas Connection Pipe Size (in.) Compressor Outdoor Sound Rating (dB) Outdoor Coil -Type Tube Size (in.) OD Face Area (sq ft) Rows/FPI Indoor Coil -Type Tube Size (in.) Face Area (sq ft) Rows/FPI Refrigerant Control Drain Connection No/Size (in.) Outdoor Fan -Type No. Used/Diameter (in.) DriveType/No. Speeds CFM No. Motors/HP Motor RPM Direct Drive Indoor Fan -Type No. Used/Diameter (in.) DriveType/No. Speeds No. Motors Motor HP (Standard/Oversized) Motor RPM (Standard/Oversized) Motor Frame Size (Standard/Oversized) RT•PRC006•EN Yscc*o AN YSC060A1 TRANS' General (5 - 6 Tons) Data Standard Efficiency 5Ton Convertible 6Ton Convertible YSC060A3, A4, AW, AK YSC072A3, A4, AW, AK 63,100 63,100 72,000 9.90/— 10.20/— — /10.2" 2,000/2,000 2,000/2,000 2,400/2,100 60,000 60,000 69,000 626 6.78 6.77 Low Medium High Low Medium High Low Medium High 60,000 80,000 130,000 60,000 80,000 130,000 80,000 120,000 150,000 47,000 63,000 103,000 48,000 64,000 104,000 64,800 97,200 121,500 81 81 . 80 81 81 80 81 81 81 81 81 80 81 81 80 81 81 81 2 2 3 2 2 3 2 3 3 1 1 1 1 1 1 1 1 2 4.5/14.0 10.0/14.0 1/2 1/2 1/2 1/Climatuff Scroll 84 Lanced 0.3125 8.81 2/17 Lanced 0.3125 5.00 3/16 Short Orifice 1/3/4 NPT Propeller 1/22 Direct/1 3,470 1/0.33 1075 FC Centrifugal 1/11 x 11 Direct/2 1 0.90/1.00 985/1,080' 48/48 4.5/14.0 10.0/14.0 1/2 1/2 1/2 1/2 4.5/14.0 10.0/14.0 1/2 3/4 1/Climatuff Scroll 1 /Climatuff Scroll 84 88 Lanced Lanced 0.3125 0.3125 8.81 13.88 2/17 2/17 Lanced Lanced 0.3125 0.3125 5.00 9.89 3/16 2/16 Short Orifice Short Orifice 1/ NPT 1/ NPT Propeller Propeller 1/22 1/26 Direct/1 Direct/1 3,470 6,100 1/0.33 1/0.70" 1,075 1,075 FC Centrifugal N/A 1/11 x 11 N/A Direct/2 N/A 1 N/A 0.90/1.00t N/A 985/1,080' N/A 48/48 N/A RECEIVED OI'Y1f OF TUKW ILA JUL 292U5 PERMIT CENTER 17 r. • TRANE" Table GD-2 — Continued General Data (5 - 6 Tons) Standard Efficiency 5Ton Convertible 6Ton Convertible YSC060A1 YSC060A3, A4, AW, AK YSC072A3, A4, AW, AK Belt Drive Indoor Fan -Type — FC Centrifugal FC Centrifugal No. Used/Diameter (in.) 1/11 x 11 1/12 x 12 ()riveType/No. Speeds — I3eltNariable Sheave BelWariable Sheave No. Motors — 1 1 Motor HP (Standard/Oversized) — 1.00/— 1.002.00" Motor RPM (Standard/Oversized) — 1,750/ — 1,750/1,750 Motor Frame Size (Standard/Oversized) — 48/— 56/56 Fiibrs -Type Furnished " Throwaway Throwaway Throwaway (No.) Size Recommended (2) 20 x 25 x 1 (2) 20 x 25 x 1 (4) 16 x 25 x 2 Ratrigermt Charge (Lbs of R -22) 4.7 4.9 71 Notes: 1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb. 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to *20% of nominal cfm. Units are certified in accordance with the Unitary Air-Conditioner Equipment certification program. which is based on ARI Standard 210/240 except AK (380V/60 Hz) units. 2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. 3. Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80° F ambient. 80° F entering dry bulb. and 67° F entering wet bulb at ARI rated cfm. 4. Heating Performance limit settings and rating data were established and approved under Laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. 6' AFUE is rated in accordance with DOE test procedures. 6.' Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table PD•90. 7. Refrigerant charge is an approximate value. For a more precise value. see unit nameplate and service instructions. 6 YSC060A1,3.4,W Oversized Motor and YSCO60AK Standard Motor Fan Diameter is 12 x 11. 9. Motor RPM shown is low speed. High speed RPM 1s 1100/1135. 10. Filter size shown is for low and medium heat models. High heat model filter size recommended is 20 x 30 x 1. 11. Optional 2" pleated filters also available. 12. YSC072A when used in a horizontal application has an EER of 10.1 and System Power (kWA of 6.83. 13. Medium heat is not available for Al( (380V/ 60 Hz) units. 14. Outdoor motor is 0.75 hp for AK (380V/60 Hz) units. 15. Outdoor motor is 0.40 hp for AK (380V/60 Hz) units. 16. Standard Motor is 1.00 hp for YSCO60AK 1380V/60 Hz) units. 17. Standard Motor is 2.00 hp for the YSC072AK )380V/60 Hz) units. FIECEIVED CITY OF TUKWILA JUL 2 9 `1UO5 PERMIT CENTER 18 R1= PRC006 -E Tons 3 4 6 94 ( TRANER Table W -1 — Maximum Unit And Comer Weights (Lbs) And Center Of Gravity Dimensions (In.) Unit _Maximum Weights (Lbs)' Comer (LW (L Center of Gravity (In.) Model No. Shipping Net A B C YSC048A YH0048A YSCO60A YHCO60A YSCO36A 572 480 151 124 96 109 32 19 YH0036A 589 497 158 128 101 110 32 19 597 505 159 130 108 103 33 19 631 539 166 133 114 126 32 20 614 522 169 134 105 114 32 18 666 574 179 140 119 136 32 20 878 735 249 193 132 161 39 21 915 772 249 198 141 184 39 22 YSC072A YH0072A YSC090A 963 71 YSC092A 965 YHO 92A 1066 81/2 YSC102A 1042 YHC102A 1100 10 YSC120A 1063 YHC120A 1203 Notes: 1. Corner weights are given for information only. 2. Weights are approximate. Weights t 820 822 923 899 951 968 1060 CENTER OF GRAVITY WIDTH RECEIVED CITY OF "F OMA ju1- 2 9 11un3 PE,tMV T MOTES D CENTER OF GRAVITY 213 277 306 297 310 317 342 CENTER OF GRAVITY 4 LENGTH 208 222 243 243 252 261 277 146 147 165 165 175 177 197 193 175 210 194 220 202 245 Accessory Economizer Barometric Relief Powered Exhaust D Length Width 38 22 40 21 39 22 40 21 40 22 41 21 40 22 Table W2 — Factory-installed Options Net Weights (Lbsl'• Net Weight 3-5Tons 6.10Tons 26 36 7 10 80 Motorized Outside Air Damper 20 30 Manual Outside Air Damper 16 26 Roof Curb 70 115 Oversized Motor 5 8 Belt Drive Motor 31 — Smoke Detector, Return 7 7 Smoke Detector, Supply 5 5 Coil Guards 12 20 Hinged Doors 10 12 Powered Corwenience Outlet 38 38 Through the Base Electrical 8 13 Through the Base Gas 5 5 Unit Mounted Circuit Breaker 5 5 Unit Mounted Disconnect 5 5 Novar Control 8 8 Dehumidification (Hot Gas Reheat) Coil 15 25 Notes: 1. Weights for options not listed are c 5 Ibs. 2.Net weight should be added to unit weight when ordering lactory•installed accessories RT PRCnr1f;.F N ,ttie1111L r .M22 ACTIVITY NUMBER: M05 -112 DATE: 7 -29 -05 PR07ECT NAME: GENERAL BUILDERS SUPPLY SITE ADDRESS: 510 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENT Buil ing 'vision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 8-2-0 Complete PLAN REVIEW/ROUTING SLIP w Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route E Structural Review Required y� 0 t 8 Z Fire Prevention Structural ❑ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents /routing slIp.doc 2 -28.02 Planning Division Permit Coordinator Not Applicable ❑ ❑ No further Review Required ❑ DATE: DUE DATE: 8 -30 -05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 1 License Information License FIVESM *010JT Licensee Name FIVE STAR MECHANICAL Licensee Type CONSTRUCTION CONTRACTOR UBI 601937083 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 4210 B ST NW STE F Address 2 City AUBURN County KING State WA Zip 980011717 Phone 2538528284 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/30/1999 Expiration Date 4/30/2006 Suspend Date Separation Date Parent Company Previous License COMFOP *064D2 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WARE, GERALD L Cancel Date 01/01/1980 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 OLD REPUBLIC SURETY CO YLI237591 04/30/2002 Until Cancelled $ 12,000.00 03/04/2002 Look Up a Contractor, Electrician or Plumber License Detail , Page 1 of 2 Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer. aspx ?License =Fl V ESM* 010JT 08/09/2005 1 u'aw'ii6d.'� AtpJddaYk�a�:�;:Y:LZb:::r ,. r F625- 052.000,(8/97). DEPARTMENT OF LABOR AND REGISTERED. AS PROVIDED CONST CONT GENERAL FIVE STAR MECHANICAL 4210 B ST .NW STE F AUBURN WA 98001 -1717 INDUSTRIES BY LAW AS EGIST. # EXP DATE`' CCO1 ` F IVESM *010JT ` 0.4/30 "/2006. EFFECTIVE' ° 04/30/1999 ANGELA R. ALLEN State Washington My Commission Expires February 11, 2009 • • • s/ File: M05 -0112 35mm Drawing #1 I e Plan APProva the of a � .11■11._ • RC-1 : Remove eX15A-In Tr ilea pump replQce wri-h new 77%ane 3Qs/ekt$r;c unit • AC-a: femo ve. ex oshrn Trnne hem p ump repkice w r}h nee tone 8aJe�;c unit • a0:ti, unfb reiu)re 3c1.5 P'P'!! exts613 mel-er 1-o -}he roc�'r, p1n will be run up -i'he in wall, p ene4rn rocr9 - }}per, run -Ea-}he u • Links \ be rnown�Cl on ems-bin orbs us n �� "9 � 9 Curb ctdQ�-ers FiLE comer Permit No. By 1415 approval is subject to errors and omiss f construction documents does not authorize of any adopted Dade or ordinance. Rer,eipt Field Copy and conditions Is adcnowiedged: City of 1tikwila BUILDING DIVISION d9. of work without prior approval of Tcr lanrilo Building Division. NOTE: Revisions will require a new plan submittal and may indude additional plan review fees. SEPARATE PERMIT REQUIRED FOR: D Mechanical 1 Electrical sr Plumbing ib Gas Pip!ng City Of Tukw a S#rander 6Nd. III ) III 1 1 1I, ILr ijrI 1 liillI il1 ili( ali I LI1( �� 3I �I L II _ I11 ih - III 4I i it I I Ili � i!1 1 1 1 5 I - 1 1i III I1I+I1I t I Inch 1I I ( 1 119 I L ti L Z L L t ,0 6 :. .,.. 8 L, g.._._w.. 5 q Z 6 w3 iiiiliiiIIIIILL LIII ILIIIlIIIIIIIII .II_IIIIIIILIiiii iiiiliiiiiiiIliiiIII I� 111 11 111111 I II� I.. I I (III I�IIII I IIII�I IIIIIII�IIIIIIIII�IfIllllll�llllltlll�lllll Par )fl3 REVIEWED FOR CODE COMPLIANCE pDMrnIIT[p AUG - 5 20 City Of Tukvvila � BUILDING DIVISION Genecal &idersSqpp1y SJb3frpder 6)vd Tukui& CITY OF TUKWIL q . U L 2 9 2005 PERMIT CENTER