HomeMy WebLinkAboutPermit M05-131 - NGUYEN RESIDENCENGUYEN RESIDENCE
Parcel No.: 2610000080
Address: 4825 S 145 ST TUKW
Suite No:
Tenant:
Name: NGUYEN RESIDENCE
Address: 4825 S 145 ST, TUKWILA WA
DESCRIPTION OF WORK:
REPLACE 3 TON 12 SEER LENNOX A/C UNIT.
Value of Mechanical: $4,500.00
Type of Fire Protection: NONE
doc: IMC- Permit
City 6A Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: ci.tukwila.wa.us
Owner:
Name: TRIDOR INC
Address: 2226 ELLIOTT AV, SUITE A, SEATTLE WA
Contact Person:
Name: STEVE CLARK
Address: 3616 S GENESEE ST, SEATTLE WA
Contractor:
Name: GENESEE FUEL & HTG CO INC
Address: PO BOX 18206, SEATTLE WA
Contractor License No: GENESFH37006
Furnace: <100K BTU 1
>100K BTU 0
Floor Furnace 0
Suspended /Wall /Floor Mounted Heater 0
Appliance Vent 0
Repair or Addition to Heat/Refrig /Cooling System.... 0
Air Handling Unit <10,000 CFM 0
>10,000 CFM 0
Evaporator Cooler 0
Ventilation Fan connected to single duct 0
Ventilation System 0
Hood and Duct 0
Incinerator: Domestic 0
Commercial /Industrial 0
MECHANICAL PERMIT
Fees Collected: $175.56
International Mechanical Code Edition: 2003
EQUIPMENT TYPE AND QUANTITY
* *continued on next page **
M05 -131
Permit Number:
Issue Date:
Permit Expires On:
Phone: 206 - 443 -7735
Phone: 206 - 722 -1545
Phone: 206- 722 -1545
Expiration Date:09 /01/2007
Steven M. Mullet, Mayor
Steve Lancaster, Director
M05 -131
09/01/2005
02/28/2006
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP/1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood /Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment 0
Printed: 09 -01 -2005
Permit Center Authorized Signature:
Signature:
Print Name:
doc: IMC- Permit
City 6? Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: ci.tukwila.wa.us
!pull
�1`�SS7�P14 7 V ?If
M05-131
M05 -131
Permit Number: M05-131
Issue Date: 09/01/2005
Permit Expires On: 02/28/2006
Date:
Steven M. Mullet, Mayor
Steve Lancaster, Director
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does. not presum= to give authority to violate or cancel the provisions of any other state or local laws
regulating construction •rthe pe ormanc: of work. I am authorized to sign and obtain this mechanical permit.
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
Printed: 09 -01 -2005
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2610000080 Permit Number: M05 -131
Address: 4825 S 145 ST TUKW Status: ISSUED a: tu
Suite No: Applied Date: 09/01/2005 u6 13
Tenant: NGUYEN RESIDENCE Issue Date: 09/01/2005 v p
co 0
co L1J
F
CD u.
O
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the 2
Building Official.
1: ** *BUILDING DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
J
u_ ?
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to = O
start of any construction. These documents shall be maintained and made available until final inspection approval is 1 w
granted. ?
ZO
4: All construction shall be done in conformance with the approved plans and the requirements of the International w w
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. v o
5: Manufacturers installation instructions shall be available on the job site at the time of inspection. o E-
wW
6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the c)
International Building Code and the Washington State Ventilation and Indoor Air Quality Code. �!- z
ui
7: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances U
shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, p ~
bathrooms, toilet rooms, storage closets, surgical rooms. Z
8: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE
GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that
the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of
Public Health - Seattle and King County (206/296- 4932).
10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Conditions
* *continued on next page **
M05 -131
Printed: 09 -01 -2005
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any
regulating construction or e-pe ormance of work.
Signature:
doc: Conditions
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
j gjs•, vi /S
Date: )// / Jr—
of law and ordinances
other work or local laws
M05 -131 Printed: 09 -01 -2005
iV
Site Address: L sac S • (t-F s S�
Tenant Name:
Property Owners Name: CH Rt. 1.4.\/ F.-A)
L &2 S . ►Lisp S j-
Mailing Address:
Name:
Company Name:
Mailing Address:
CITY OF TUKWILA
Community Developmentartment
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
E -Mail Address:
Contact Person: S'1 0._1(k_ vl�
ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record
gitpennita plua\ice changea\pmnit application (7.2004)
Revised: 64-05
bh
e Goa- Ica r /x_,
- 3(0( (p s. rGe1 s
Page 1
Building Perm
Mechanical Permit No.
Public Works Permit No
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.: ?-G I O O 00 0 cR" <�
Suite Number: Floor:
New Tenant: ❑ .... Yes ❑ ..No
k wi + Lf
City
IdU
State
Day Telephone:
Mailing Address:
City
State
Fax Number:
GENERAL CONTRACTOR INFORMATION (Mechanical Contractor information on back page)
,--e_o _ , L1 l r g
City
Day Telephone: 9--0L0 a l S1 T
State Zip
E -Mail Address: Fax Number:
Contractor Registration Number: 6 Fiti )= S l-\ 37p (a Expiration Date: /' G /0 S
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
ARCHITECT OF. RECORD - Al! plans:must be wet stamped by Architect of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
Zip
Zip
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
BUILDING PERMIT INFORMATION 206-43173670
Valu
11 it ofPt'I�q bid price): $ Existing Building Valuation: $ 416
Scope of Work (please provide detailed information):
Will there be new rack storage? ❑ ..Yes 0.. No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑..Sprinklers ❑ ..Automatic Fire Alarm ❑..None ❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No
If' yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
q:\\permits plus \iicc changes permit application (7.2004)
Revised 64145
bh
Page 2
Existing
Interior
Remodel
Addition to
Existing
Structure
New
Type of
Construction
per IBC
Type of
Occupancy per
IBC
1't Floor
rd Floor
3` Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
BUILDING PERMIT INFORMATION 206-43173670
Valu
11 it ofPt'I�q bid price): $ Existing Building Valuation: $ 416
Scope of Work (please provide detailed information):
Will there be new rack storage? ❑ ..Yes 0.. No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑..Sprinklers ❑ ..Automatic Fire Alarm ❑..None ❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No
If' yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
q:\\permits plus \iicc changes permit application (7.2004)
Revised 64145
bh
Page 2
PUBLIC WORKS PERMIT INFORMATION - 206- 433 -0179
❑ ...Total Cut
❑ ...Total Fill
Call before you Dig: 1- 800 - 424 -5555
Scope of Work (please provide detailed information):
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila 0... Water District #125
❑...Water Availability Provided
Sewer District
❑...Tukwila ❑ ... ValVue ❑ .. Renton ❑ ...Seattle
❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided
❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ")
❑ ...Technical Information Report (Storm Drainage)
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 72 hours
❑ ...Right -of -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
cubic yards
cubic yards
❑ ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
❑ ...Frontage Improvements
❑ ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ ...Permanent Water Meter Size...
❑ ...Temporary Water Meter Size ..
❑ ... Water Only Meter Size
❑ ...Sewer Main Extension Public _
❑ ...Water Main Extension Public _
q:Upermits plusiicc changatpermit application (7.2004)
Revised: 6.405
bh
Is
„
„
❑ .. Abandon Septic Tank
❑ .. Curb Cut
❑ .. Pavement Cut
❑ .. Looped Fire Line
„
„
„
WO#
WO#
WO#
Private
Private
❑ .. Highline
❑ ...Renton
❑ .. Geotechnical Report ❑...Traffic Impact Analysis
❑ .. Maintenance Agreement(s) ❑...Hold Harmless
❑ .. Right -of -way Use - Profit for less than 72 hours
❑ .. Right -of -way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
Page 3
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑ ...Deduct Water Meter Size
FINANCE INFORMATION
Fire Line Size at Property Line
❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment
Monthly Service Billing to:
Name:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:.
Number of Public Fire Hydrant(s)
Day Telephone:
City
State
Zip
Day Telephone:
City
State
Zip
Unit Type:
Qty .
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Fumace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
•
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended /Wall /Floor
Mounted Heater
Ventilation System
Wood /Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Flood and Duct
Water Heater
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
I
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
Other Mechanical
Equipment
MECHANICAL PERMIT INFOATION. — 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address: 3(„ t c 5 . /
' • ' - City State Zip
Contact Person: S C IAA Day Telephone: D 1 a a l SCI S'�
E -Mail Address: Fax Number:
Contractor Registration Number: 6 6 IU G-S r H . 3 - 1.11 G (.o Expiration Date: q ( //
(O /
**An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $ 5'111TS al, -
Scope of Work (please provide detailed information): 'a) -e .g I / C `tA -4-
Use: Residential: New .. `t Replacement ❑
Commercial: New ....❑ Replacement ❑
Fuel Type: Electric LW Gas ....0 Other:
Indicate type of mechanical work being installed and the quantity below:
PERMIT APPLICATION NOTES Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY T
PENALTY OF PERJ BY T
BUILDING OWNE' OR AUT QIRIZEDL. ' E T:
Signature:
Print Name:
Mailing Address:
Date Application Accepted:
q.Wpenads plusbcc changestpennit application (7.2004)
Revised 6.1.05
bh
EAD ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
OF HE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Page 4
Date: q/1 (0
Day Telephone: o 3 . g7 & L (
•
City State
Zip
Date Application Expires:
Staff Initials:
Payee:
ACCOUNT ITEM LIST:
Description
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2610000080
Address: 4825 S 145 ST TUKW
Suite No:
Applicant: NGUYEN RESIDENCE
NORTHWEST PERMIT INC
Payment Check 5216
MECHANICAL - RES
RECEIPT
1 Receipt No.: R05 -01293 Payment Amount: 175.56
Initials: BLH Payment Date: 09/01/2005 11:21 AM
User ID: ADMIN Balance: $0.00
TRANSACTION LIST:
Type Method Description Amount
175.56
Account Code Current Pmts
000/322.100 175.56
Permit Number: MO5-131
Status: APPROVED
Applied Date: 09/01/2005
Issue Date:
Total: 175.56
6730 09/02 9710 TOTAL 175.56
Printed: 09 -01 -2005
4
•
•
•
� d es D11Ii5I
ON
OAArisl -oe6r /J4e
Ai ' 5 S. 145 5J.
— r 1.4ML c /I4 givocK
10 Cat' FILE O0P1f
It No. -heLali213(
leView . , , is • bh errors and omiss5orte.
of
•, does not authorize
the vloIaUort o f y Code or ordinance. Rerek*
OF alippoMed
i fr •
ey �
Date: -u,( VS
Is acknowledged
41
"far
VVI:D FOR
CODE CON PLIANCE
a o fAR n
SEP - 1 2005
City Of Takwila /'gyp
BI 1117
D eW.- w440A
CEIVED
CITY OF TUKWILA
AUG 2 4 2005
PERMIT CENTER
BIBIMUSW
No ch sages shall be made to the ccepe
of worts without prior approve! of
Yokwila Building Division.
u re a new p al n submittal
and may include additional plan review fees.
LENNOX
REVIEWED FO
CODE COMPLIAN
An[ffal"'+ mn
SEP --1 2005
02002 Lennox Industries Inc.
Dallas, Texas
City Of Tukwila
ll�I��I�► FrcTo
FILE COPY \
----- INSTALLATION
INS UCTIONS AUG 2 /4 2005
PERMIT CFNTER
HSXAl2 Outdoor Unit
HSXAl2 outdoor units use R41OA which is an ozone
friendly HFC refrigerant. This unit must be installed with a
matching indoor coil and line set as outlined in the Lennox
Engineering Handbook. HSXAl2 outdoor units are de-
signed for use in expansion valve (TXV) and fixed orifice
systems. Refer to the Lennox Engineering Handbook for
expansion valve kits which must be ordered separately. A
filter dryer approved for use with R41 OA has been shipped
with the unit. This component must be installed prior to op-
erating the unit. Failure to install the provided filter dryer
will void the warranty.
I Shipping and Packing List
1 - Assembled HSXAl2 outdoor unit
1 - Liquid line filter drier (approved for use with R41OA
systems)
1 - Fixed orifice refrigerant metering device
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
AWARNING
Improper installation. adjustment. alteration. service
or maintenance can cause property damage. person-
al injury or loss of life. Installation and service must
be performed by a qualified installer or service
agency.
AIMPORTANT
This unit must be matched with an indoor coil as
specified in Lennox' Engineering Handbook. Coils
previously charged with R22 must be flushed.
04/04
1111111 Page 1
` 131
::,ti''_�.; i • t:_ c- tiaisS�:: isziaa' �F,. i1? i:. a. in.-...... s.;. wtr� ..::,::.s���.:..,:n.u�:w... w: .4r t .aw�..«a,.
HSXAl2 Series Units
CONDENSING UNITS
504,540M
04/04
Supersedes 12/03
RECEIVED
CITY OF TUKWILA
Technical
Publications
Litho U.S.A.
Table of Contents
HSXAl2 Outdoor Unit 1
Shipping And Packing List 1
General Information 1
Unit Dimensions 2
Setting the Unit 3
Electrical 3
Refrigerant Piping 5
Flushing Existing Line Set & Indoor Coil 5
Refrigerant Metering Device 11
Manifold Gauge Set 11
Service Valves 12
Leak Testing 13
Evacuation 13
Start-up 14
Charging 14
System Operation 18
Maintenance 18
Optional Accessories 18
HSXAl2 Check Points 19
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
I General Information
These instructions are intended as a general guide and do
not supersede national or local codes in any way. Consult
authorities having jurisdiction before installation.
A WARNING
This product and /or the indoor unit it is matched with
may contain fiberglass wool.
Disturbing the insulation during installation. mainte-
nance, or repair will expose you to fiberglass wool
dust. Breathing this may cause lung cancer. (Fiber-
glass wool is known to the State of California to
cause cancer.)
Fiberglass wool may also cause respiratory, skin,
and eye irritation.
To reduce exposure to this substance or for further
infort consult material safety data sheets
available from address shown below. or contact your
supervisor.
Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379 -9900
504, 54
111 11111 lil 11 111 III II UIU I III 01 11111111111 1111
Model No.
A
B
C
HSXAl2 -018
HSXAl2 -024
in.
25
24-1/4
24-1/4
mm
635
616
616
HSXAl2 -030
HSXAl2 -036
HSXAl2 -042
HSXAl2 -048
in.
33
32 -1/4
24-1/4
mm
838
819
616
HSXAl2 -060
in.
29
28-1/4
28-1/4
mm
737
718
718
1.1.Init Dimensions`' - Inches (mm)
INLET
AIR
INLET AIR
Top View
Side View
3,4
(19)
•
4
2451)
OPTIONAL UNIT
STAND-OFF KIT (4)
(Field Installed)
COIL DRAIN OUTLETS
(Around perimeter of base)
VAPOR LINE
CONNECTION
LIQUID LINE
CONNECTION
ELECTRICAL
INLETS
OPTIONAL UNIT
STAND-OFF KIT (4)
(Field Installed)
OUTDOOR
COIL FAN
6-318
(162)
COMPRESSOR
VAPOR &
LIQUID LINE
CONNECTION
2-3/4 (70)
43/8
(111)
(;62) (1
Top View Base Section
C
DI SCHARGE AIR
Side View
43/8
Setting the Unit
ACAUTION
In order to avoid injury, take proper precaution when
lifting heavy objects.
ACAUTION
Sharp sheet metal edges can cause
installing the unit. avoid accidental
sharp edges.
e er to un t • men
injury. When
contact with
ons or siz ng mount ng s a •, p at-
forms or supports. Refer to figure 1 for installation clear-
ances.
Installation Clearances
"NOTE - A service clearance of 30" (762 mm) must be main-
tained on one of the sides adjacent to the control box. Clear-
ance to one of the other three sides must be 36" (914 mm).
Clearance to one of the remaining two sides maybe 12" (304
mm) and the final side may be 6" (152 mm).
NOTE - A clearance of 24" (610 mm) must be maintained
between two units.
NOTE - 48" (1219 mm) clearance required on top
of unit. Maximum soffit overhang Is 36" (914 mm).
Figure 1
Slab Mounting
When installing a unit at grade level, the top of the slab
should be high enough above the grade so that water from
higher ground will not collect around the unit. See figure 2.
Slab should have a slope tolerance away from the building
of 2 degrees or 2 inches per 5 feet (51 mm per 1524 mm).
Refer to roof mounting section for barrier construction if
unit must face prevailing winter winds.
Slab Mounting At Ground Level
structure discharge air
Ji
JL
Mounting slab must slope
away from building.
I
ground level
Figure 2
Page 3
Roof Mounting
Install unit at a minimum of 4 inches above the surface of
the roof. Care must be taken to ensure weight of unit is
properly distributed over roof joists and rafters. Either red-
wood or steel supports are recommended.
Electrical
In the U.S.A., wiring must conform with current local codes
and the current National Electric Code (NEC). In Canada,
wiring must conform with current local codes and the current
Canadian Electrical Code (CEC).
Refer to the furnace or blower coil installation instructions
for additional wiring application diagrams and refer to unit
nameplate for minimum circuit ampacity and maximum
overcurrent protection size.
A WARNING
Unit must be grounded in accordance with national
and local codes.
ELECTRIC SHOCK HAZARD.
Can cause injury or death.
1 - Install line voltage power supply to unit from a properly
sized disconnect switch.
2 - Ground unit at unit disconnect switch or to an earth
ground.
NOTE - To facilitate conduit, a hole is in the bottom of
the control box. Connect conduit to the control box us
ing a proper conduit fitting.
NOTE - Units are approved for use only with copper
conductors.
24V, Class II circuit connections are made in the low
voltage junction box. Refer to figure 4 for field wiring
diagram.
NOTE - A complete unit wiring diagram is located in
side the unit control box cover.
3 - Install room thermostat (ordered separately) on an in-
side wall approximately in the center of the conditioned
area and 5 feet (1.5 m) from the floor. It should not be
installed on an outside wall or where it can be effected
by sunlight, drafts or vibrations.
4 - Install low voltage wiring from outdoor to indoor unit
and from thermostat to indoor unit. See figure 3.
Model
Valve Field Size
Connections
Recommended Line Set
Liquid
Line
Vapor
Une
Liquid
Line
Vapor
Line
L15
Line Sets
-018
3/8 in.
(10 mm)
5/8 in.
(16 mm)
3/8 in.
(10 mm)
5/8 in.
(19 mm)
L15-26
15 ft. - ft.
(4.6m -1 1 5 m)
030
-036
3/8 in.
(10 mm)
3/4 in.
(19 mm)
3/8 in.
(10 mm)
3/4 in.
(19 mm)
15 ft. - 50 ft.
(4.6 m - 15 m)
- 042
- 048
3/8 in.
(10 mm)
7/8 in.
(22 mm)
3/8 in.
(10 mm)
7/8 in.
(22 mm)
L15-65
(4.6 m - 15 m)
-060
3/8 in.
(10 mm)
1 -1/8 in.
(29 mm)
3/8 in.
(10 mm)
1 -1/8 in.
(29 mm)
Field
Fabricated
[Refrigerant
If the HSXAl2 unit is being installed with an indoor coil and
line set, make the refrigerant connections as outlined in this
section. If an existing line set and /or indoor coil is going to
be used to complete the HSXAl2 system, refer to this sec-
tion, as well as the flushing section which follows.
Field refrigerant piping consists of liquid and vapor lines
from the outdoor unit (sweat connections) to the indoor coil
(flare or sweat connections). Use Lennox L15 (sweat, non -
flare) series line sets as shown in table 1 or use field -fabri-
cated refrigerant lines. Refer to Refrigerant Piping Guide
(Corp. 9351 -L9) for proper size, type, and application of
field- fabricated lines. Valve sizes are also listed in table 1.
Refrigerant Line Connections
HSXAl2 Matched with New Indoor Coil and Line Set
If the HSXAl2 is being used with an existing indoor coil
which was equipped with a liquid line which served as
a metering device (RFC!), the liquid line must be re-
placed prior to the installation of the HSXAl2 unit.
If refrigerant lines are routed through a wall, seal and isolate
the opening so vibration is not transmitted to the building.
Table 1
Refrigerant Line Sets
NOTE - Units am designed for line sets of up to fifty feet (15
m). For applications longer than fifty feet, consult the Len-
nox Refrigerant Piping Guide (Corp. 9351 -L9). Select fine
set diameters from table 1 to ensure that oil returns to the
compressor.
Installing Refrigerant Line
During the installation of any heat pump or a/c system, it is
important to properly isolate the refrigerant lines to prevent
unnecessary vibration. Line set contact with the structure
(wall, ceiling or floor) causes some objectionable noise
when vibration is translated into sound. As a result, more
energy or vibration can be expected. Closer attention to
line set isolation must be observed.
Following are some points to consider when placing and
installing a high - efficiency outdoor unit:
1 - Placement - Be aware some localities are adopting
sound ordinances based on how noisy the unit is from
the adjacent property not at the original installation.
Install the unit as far as possible from the property line.
When possible, do not install the unit directly outside a
window. Glass has a very high level of sound transmis-
sion.
2- Line Set Isolation - The following illustrations demon-
strate procedures which ensure proper refrigerant line
set isolation. Figure 5 shows how to install line sets on
vertical runs. Figure 6 shows how to install line sets on
horizontal runs. Figure 7 shows how to make a transition
from horizontal to vertical. Finally, figure 8 shows how to
place the outdoor unit and line set.
Outside Wal
Liquid Line
Vapor Line
(wrapped with Arm - flex)
tside Wall
IMPORTANT - Refrigerant
lines must not contact
structure.
r Wood Block
Between Studs
Refrigerant Line Sets
How To Install Vertical Runs
(new construction shown)
NOTE - Similar installation practices should be used if
line set is to be installed on exterior of outside wall.
IMPORTANT - Refrigerant
lines must not contact wall.
Figure 5
Page 6
Vapor Line Liquid Line
Wire Tie
Inside Wall
Strap
Sleeve
Wire Tie
Wood Block
Wire Tie
Strap
Sleeve
To hang line set from joist or rafter,
use either metal strapping material
or anchored heavy nylon wire ties.
Tape or Wire Tie
Refrigerant Line Sets:
Installing Horizontal Runs
8 feet
Metal Sleeve
8 feet
Wire Tie
(around vapor line only)
Strapping Material (around vapor line only)
Tape or Wire Tie
Floor Joist or Roof Rafter
Strap the vapor line to the joist or rafter at 8 ft.
intervals then strap the liquid line to the vapor line.
Figure 6
Page 7
Anchored Heavy
Nylon Wire Tie
Wall
Stud
Metal
Sleeve
Refrigerant Line Sets:
Transition From Vertical To Horizontal
Strap Liquid Line
To Vapor Line
Vapor Line
Wrapped in Liquid Line
Armaflex
Automotive
Muffler -Type
Hanger
Wall
Stud
'
Metal Vapor Line
Sleeve Wrapped in
Armaflex
Strap Liquid Line
To Vapor Line
Liquid Line
Figure 7
Outside Unit Placement and Installation
Install unit away from windows.
Two 90° elbows
installed in line set
will reduce line set
vibration.
Figure 8
Page 8
General Model No.
Data Nominal Tonnage (kW)
HSXAl2 -018
1.5 (5.3)
HSXAl2 -024
2 (7.0)
HSXAl2 430
2.5 (8.8)
HSXAl2 -036
3 (10.6)
HSXAl2-042
3.5 (12.3)
HSXAl2-048
4 (14.1)
HSXAl2-060
5 (17.6)
Connections Liquid line (o.d.) - in. (mm)
(sweat) Suction line (o.d.) - in. (mm)
3/8 (9.5)
3/4 (19.1)
3/8 (9.5)
3/4 (19.1)
3/8 (9.5)
3/4 (19.1)
3/8 (9.5)
3/4 (19.1)
3/8 (9.5)
7/8 (22.2)
3/8 (9.5)
7/8 (22.2)
3/8 (9.5)
1 -1/8 (28.6)
Refrigerant 1 R-410A charge furnished
3 lbs. 11 oz.
4 lbs. 2 oz.
5 lbs. 4 oz.
5 lbs. 14 oz.
6 lbs. 14 oz.
7 lbs. 15 oz.
9 lbs. 13 oz.
3 Minimum circuit ampacity
(1.67 kg)
(1.87 kg)
(2.38 kg)
(2.66 kg)
(3.12 kg)
(3.60 kg)
(4.45 kg)
Condenser Net face area - sq. ft. (m Outer
11.33 (1.05)
11.33 (1.05)
15.11 (1.40)
15.11 (1.40)
15.11 (1.40)
15.11 (1.40)
16.33 (1.52)
Coil Inner
- - -
- - -
5.4 (0.50)
5.4 (0.50)
14.4 (1.34)
14.4 (1.34)
15.71 (1.46)
Tube diameter - in. (mm)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
No. of rows
1
1
2
2
2
2
2
Fins per inch (m)
22 (866)
22 (866)
18 (748)
18 (748)
22 (866)
22 (866)
22 (866)
Condenser Diameter - in. (mm)
18 (457)
18 (457)
18 (457)
18 (457)
18 (457)
18 (457)
22 (559)
Fan No. of blades
3
3
4
4
4
4
4
Motor hp (W)
1/6 (124)
1/6 (124)
1/6 (124)
1/6 (124)
1/3 (249)
1/4 (187)
1/3 (249)
Cfm (Us)
2200 (1040)
2200 (1040)
2430 (1145)
2430 (1145)
2800 (1320)
2785 (1315)
3790 (1790)
Rpm
1100
1100
1090
1090
1100
1050
1075
Watts
180
180
190
190
310
275
370
Shipping Data lbs. (kg) 1 pkg.
136 (62)
138 (63)
157 (71)
160 (73)
185 (84)
185 (84)
214 (97)
Model No.
HSXAI2
-018-230
HSXAl2
-024.230
HSXAI2
4130230
HSXAl2
-036- 230
HSXAl2
-042 -230
HSXAI2
-048- 230
HSXAI2
460.230
Line voltage data - 60hz - 1 phase
208/230
208/230V
208/230V
208 /230V
208/230V
208/230V
208/230V
nun Overcurrent Protection (amps)
20
30
30
35
40
50
60
3 Minimum circuit ampacity
13.8
17.8
19.4
20.2
25.7
30.5
36.2
Compressor Rated load amps
10.3
13.5
15.1
15.4
19.2
23.1
27.6
Power Factor
0.98
0.98
0.97
0.95
0.97
0.98
0.98
Locked rotor amps
51
61
72.5
83
104
134
158
Condenser Full load amps
1.1
1.1
1.1
1.1
1.9
1.7
1.9
Fan Locked rotor amps
1.9
1.9
1.9
1.9
4.1
3.1
4.1
Compressor Hard Start Kit
10J42
10J42
10J42
10J42
10J42
10J42
81J69
Compressor Crankcase Heater
90P12
90P12
90P12
90P12
90P12
90P12
90P12
Compressor Low Ambient Cut -Off
45F08
45F08
45F08
45F08
45F08
45F08
45F08
Compressor Time -Off Control
47J27
47J27
47J27
47J27
47J27
47J27
47J27
Freezestat 3/8 in. tubing
93G35
93G35
93G35
93G35
93G35
93G35
93G35
1/2 in. tubing
39 1429
39H29
39H29
39H29
39H29
39H29
39H29
5/8 in. tubing
50A93
50A93
50A93
50A93
50A93
50A93
50A93
Hail Guard
17L71
17L71
17L72
17L73
17L73
17L73
45M56
Low Ambient Kit
34M72
34M72
34M72
34M72
34M72
34M72
34M72
Mounting Model No.
MB2-S (69J06)
MB2 -L
69J07)
MB2 -L (69J07
Base Net Weight
6 lbs. 3 kg)
15 lbs. (7 kg)
15 lbs. (7 kg)
Dimensions - in. (mm)
22 -1/4 x 22 -1/4 x 3
32 x 34 x 3
32 x 34 x 3
(565 x 565x76)
(813x864x76)
(813x864x76)
Refrigerant 15 ft. (4.6 m) length
L15 -41 -15
L15 -41 -15
L15 -41 -15
L15 -41 -15
L15 -65-15
L15 -65-15
Field Fabricate
Line Set 20 ft. (6 m) length
L15 -41 -20
L15 -41 -20
L15 -41 -20
L15 -41 -20
- - -
30 ft. (9 m) length
L15 -41 -30
L15 -41 -30
L15 -41 -30
L15 -41 -30
L15 -65-30
L15 -65-30
Field Fabricate
40 ft. (12 m) length
L15 -41-40
L15 -41-40
L15 -41-40
L15 -41-40
L15 -65-40
L15 -65-40
Field Fabricate
50 ft. (15 m) length
L15 -41 -50
L15 -41 -50
L15 -41 -50
L15 -41 -50
L15 -65 -50
L15 -65 -50
Field Fabricate
Unit Stand-Off Kit
94J45
94J45
94J45
94J45
94J45
94J45
94J45
SPECIFICATIONS -1 PHASE MODELS
ELECTRICAL DATA
Data
2 Maxi
HSXAl2 / Page 4
OPTIO
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
i Refrigerant charge sufficient for 20 ft. (6.0 m) length of re rigerant lines
2 HACR type circuit breaker or fuse.
3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
SPECIFICATIONS - 3 PHASE MODELS
General Model No.
Data Nominal Tonnage (kW)
HSXAl2 -036
3 (10.6)
HSXAl2-048
4 (14.1)
HSXAI2-060
5 (17.6)
Connections Liquid line (o.d.) - in. (mm)
3/8 (9.5)
3/8 (9.5)
3/8 (9.5)
(sweat) Suction line (o.d.) - in. (mm)
3/4 (19.1)
7/8 (22.2)
1 -1/8 (28.6)
Refrigerant 1 R-410A charge furnished
5 lbs. 14 oz. (2.66 kg)
7 lbs. 15 oz. (3.60 kg)
9 lbs. 13 oz. (4.45 kg)
Condenser Net face area - sq. ft. (m Outer
15.11 (1.40)
15.11 (1.40)
16.33 (1.52)
Coll
77
35
31
Inner
5.4 (0.50)
14.4 (1.34)
15.71 (1.46)
Tube diameter - in. (mm)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
No. of rows
2
2
2
Fins per inch (m)
18 (748)
22 (866)
22 (866)
Condenser Diameter - in. (mm)
18 (457)
18 (457)
22 (559)
Fan
2.1
2.1
4.1
No. of blades
4
4
4
Motor hp (W)
1/6 (124)
1/4 (187) - 208/230V -3ph
1/3 (249)
1/3 (249) - 460V & 575V -3ph
67K90 67K89
Cfm (Us)
2430 (1145)
2785 (1315) - 208/230V -3ph
3790 (1790)
67K90
67K89
2800 (1320) - 460V & 575V -3ph
Compressor Low Ambient Cut -Off
Rpm
1090
1050 - 208/230V -3ph
1075
93G35
93G35
1100 - 460V & 575V -3ph
1/2 in. tubing
Watts
190
275 - 208/230V -3ph
370
50A93
50A93
310 - 460V & 575V -3ph
Hall Guard
Shipping Data lbs. (kg) 1 pkg.
160 (73)
185 (84)
214 (97)
Electrical Model No.
Data
Line voltage data - 60hz - 3 phase
2 Maximum Overcurrent Protection (amps)
3 Minimum circuit ampacity
HSXAl2
-036233
208/230V
25
15.4
HSXAl2
-036163
460V
10
6.9
HSXAl2
-036-575
575V
10
5.9
HSXAl2
-048-233
208/230V
35
21.7
HSXAl2
.048463
460V
15
9.8
HSXAI2
-048-575
575V
10
7.9
HSXAl2
-060-233
208/230V
40
24.5
HSXAl2
-060-463
460V
20
12.2
HSXAl2
-060-575
575V
15
9.4
Compressor Rated load amps
Power Factor
11.5
0.95
5.1
0.95
4.3
0.95
16
0.98
7.1
0.98
5.6
0.98
18.1
0.98
9
0.98
6.8
0.98
Looked rotor amps
77
35
31
91
46
37
137
62
50
Condenser Full load amps
1
0.55
0.55
1.7
0.9
0.9
1.9
0.9
0.9
Fan Locked rotor amps
2.3
1
1
3.1
2.1
2.1
4.1
2.1
2.1
OPTIONAL ACCESSORIES -MUST BE ORDERED EXTRA
Compressor Crankcase Heater
67K90 67K89
18M11
67K90
67K89
18M11
67K90
67K89
18M11
Compressor Low Ambient Cut -Off
45F08
45F08
45F08
Freezestat 3/8 in. tubing
93G35
93G35
93G35
1/2 in. tubing
39H29
39H29
39H29
5/8 in. tubing
50A93
50A93
50A93
Hall Guard
17L73
17L73
45M56
Low Ambient Kit
34M72
34M72
34M72
Mounting Model No.
MB2 -L (69J07)
MB2 -L (69J07)
MB2 -L (69J07)
Base
Net Weight
15 lbs. (7 kg)
15 lbs. (7 kg)
15 lbs. (7 kg)
Dimensions - in. (mm)
32 x 34 x 3 (813x864x76)
32 x 34 x 3 (813x864x76)
32 x 34 x 3 (813x864x76)
Refrigerant 15 ft. (4.6 m) length
L15 -41 -15
L15 -65-15
Field Fabricate
Line Bet 20 ft. (6.1 m) length
L15 -41 -20
- - -
Field Fabricate
30 ft. (9 m) length
L15 -41 -30
L15 -65 -30
Field Fabricate
40 ft. (12 m) length
L15 -41-40
L15 -65-40
Field Fabricate
50 ft. (15 m) length
L15 -41 -50
L15 -65 -50
Field Fabricate
Unit Stand -Off Kit
94J45
94J45
94J45
ELECTRICAL DAT
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1 Refrigerant charge sufficient for 20 ft. (6.0 m) length of refrigerant lines
2 IiACR type circuit breaker or fuse.
3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
HSXAl2 / Page 5
Model No.
A
B
C
HSXAl2- 018 -024 in.
mm
25
635
24 -1/4
616
24-1/4
616
HSXAl2- 030 - 036-042 -048 in.
mm
33
838
32-1/4
819
24-1/4
616
HSXAl2 -060 in.
mm
29
737
28-1/4
718
28 -1/4
718
DIMENSION
INLET AIR
TOP VIEW
LIQUID LINE
SIDE VIEW
i�
t
V
� � 2 51)
3/4
(19)
OPTIONAL UNIT
STAND -OFF KIT (4)
(Field Installed)
COIL DRAIN OUTLETS
perimeter of base)
SUCTION LINE 6.3/6 J\
CONNECTION (162)
Co NNECTION
ELECTRICAL
INLETS
OPTIONAL UNIT
STAND -OFF KIT (4
(Field Installed)
Imo- C -- ►I
COIUTD AN
COMPRESSOR
SUCTION &
LIQUID LINE
CONNECTION
(162)
°
/ � \"
COMPRESSOR
/1
6.3/8
1
TOP VIEW BASE SECTION
SIDE VIEW
43/8
(111)
License Information
License
GENESFH37006
Licensee Name
GENESEE FUEL &HTNG CO INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
578049915
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
PO BOX 18206
Address 2
01/01/1980
City
SEATTLE
County
KING
State
WA
Zip
981180206
Phone
2067221545
Status
ACTIVE
Specialty I
AIR HEAT,VENTILATION,EVAPORAT
Specialty 2
SHEET METAL
Effective Date
9/26/1963
Expiration Date
9/1/2007
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
CLARK, ANITA J
01/01/1980
CLARK, STEVEN T
01/01/1980
CLARK, DONALD S
01/01/1980
01/01/1980
HERRMANN, GAIL
01/01/1980
01/01/1980
Look Up a Contractor, Electrician or Plumber License Detail ; Page 1 of 3
Washington State Department of Labor and Industries
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
https: / /fortress.wa. gov /lni/bbip /printer. aspx ?License= GENESFH3 7006
09/01/2005
•