Loading...
HomeMy WebLinkAboutPermit M05-131 - NGUYEN RESIDENCENGUYEN RESIDENCE Parcel No.: 2610000080 Address: 4825 S 145 ST TUKW Suite No: Tenant: Name: NGUYEN RESIDENCE Address: 4825 S 145 ST, TUKWILA WA DESCRIPTION OF WORK: REPLACE 3 TON 12 SEER LENNOX A/C UNIT. Value of Mechanical: $4,500.00 Type of Fire Protection: NONE doc: IMC- Permit City 6A Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Owner: Name: TRIDOR INC Address: 2226 ELLIOTT AV, SUITE A, SEATTLE WA Contact Person: Name: STEVE CLARK Address: 3616 S GENESEE ST, SEATTLE WA Contractor: Name: GENESEE FUEL & HTG CO INC Address: PO BOX 18206, SEATTLE WA Contractor License No: GENESFH37006 Furnace: <100K BTU 1 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT Fees Collected: $175.56 International Mechanical Code Edition: 2003 EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -131 Permit Number: Issue Date: Permit Expires On: Phone: 206 - 443 -7735 Phone: 206 - 722 -1545 Phone: 206- 722 -1545 Expiration Date:09 /01/2007 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -131 09/01/2005 02/28/2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 09 -01 -2005 Permit Center Authorized Signature: Signature: Print Name: doc: IMC- Permit City 6? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us !pull �1`�SS7�P14 7 V ?If M05-131 M05 -131 Permit Number: M05-131 Issue Date: 09/01/2005 Permit Expires On: 02/28/2006 Date: Steven M. Mullet, Mayor Steve Lancaster, Director I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does. not presum= to give authority to violate or cancel the provisions of any other state or local laws regulating construction •rthe pe ormanc: of work. I am authorized to sign and obtain this mechanical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 09 -01 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2610000080 Permit Number: M05 -131 Address: 4825 S 145 ST TUKW Status: ISSUED a: tu Suite No: Applied Date: 09/01/2005 u6 13 Tenant: NGUYEN RESIDENCE Issue Date: 09/01/2005 v p co 0 co L1J F CD u. O 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the 2 Building Official. 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS J u_ ? 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to = O start of any construction. These documents shall be maintained and made available until final inspection approval is 1 w granted. ? ZO 4: All construction shall be done in conformance with the approved plans and the requirements of the International w w Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. v o 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. o E- wW 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the c) International Building Code and the Washington State Ventilation and Indoor Air Quality Code. �!- z ui 7: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances U shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, p ~ bathrooms, toilet rooms, storage closets, surgical rooms. Z 8: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M05 -131 Printed: 09 -01 -2005 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or e-pe ormance of work. Signature: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 j gjs•, vi /S Date: )// / Jr— of law and ordinances other work or local laws M05 -131 Printed: 09 -01 -2005 iV Site Address: L sac S • (t-F s S� Tenant Name: Property Owners Name: CH Rt. 1.4.\/ F.-A) L &2 S . ►Lisp S j- Mailing Address: Name: Company Name: Mailing Address: CITY OF TUKWILA Community Developmentartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 E -Mail Address: Contact Person: S'1 0._1(k_ vl� ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record gitpennita plua\ice changea\pmnit application (7.2004) Revised: 64-05 bh e Goa- Ica r /x_, - 3(0( (p s. rGe1 s Page 1 Building Perm Mechanical Permit No. Public Works Permit No Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: ?-G I O O 00 0 cR" <� Suite Number: Floor: New Tenant: ❑ .... Yes ❑ ..No k wi + Lf City IdU State Day Telephone: Mailing Address: City State Fax Number: GENERAL CONTRACTOR INFORMATION (Mechanical Contractor information on back page) ,--e_o _ , L1 l r g City Day Telephone: 9--0L0 a l S1 T State Zip E -Mail Address: Fax Number: Contractor Registration Number: 6 Fiti )= S l-\ 37p (a Expiration Date: /' G /0 S * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF. RECORD - Al! plans:must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip Zip Zip Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: BUILDING PERMIT INFORMATION 206-43173670 Valu 11 it ofPt'I�q bid price): $ Existing Building Valuation: $ 416 Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes 0.. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑..Sprinklers ❑ ..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No If' yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. q:\\permits plus \iicc changes permit application (7.2004) Revised 64145 bh Page 2 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1't Floor rd Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION 206-43173670 Valu 11 it ofPt'I�q bid price): $ Existing Building Valuation: $ 416 Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes 0.. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑..Sprinklers ❑ ..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No If' yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. q:\\permits plus \iicc changes permit application (7.2004) Revised 64145 bh Page 2 PUBLIC WORKS PERMIT INFORMATION - 206- 433 -0179 ❑ ...Total Cut ❑ ...Total Fill Call before you Dig: 1- 800 - 424 -5555 Scope of Work (please provide detailed information): Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila 0... Water District #125 ❑...Water Availability Provided Sewer District ❑...Tukwila ❑ ... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ... Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public _ q:Upermits plusiicc changatpermit application (7.2004) Revised: 6.405 bh Is „ „ ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line „ „ „ WO# WO# WO# Private Private ❑ .. Highline ❑ ...Renton ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage Page 3 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address:. Number of Public Fire Hydrant(s) Day Telephone: City State Zip Day Telephone: City State Zip Unit Type: Qty . Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU • Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Flood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System I Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFOATION. — 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: 3(„ t c 5 . / ' • ' - City State Zip Contact Person: S C IAA Day Telephone: D 1 a a l SCI S'� E -Mail Address: Fax Number: Contractor Registration Number: 6 6 IU G-S r H . 3 - 1.11 G (.o Expiration Date: q ( // (O / **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 5'111TS al, - Scope of Work (please provide detailed information): 'a) -e .g I / C `tA -4- Use: Residential: New .. `t Replacement ❑ Commercial: New ....❑ Replacement ❑ Fuel Type: Electric LW Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY T PENALTY OF PERJ BY T BUILDING OWNE' OR AUT QIRIZEDL. ' E T: Signature: Print Name: Mailing Address: Date Application Accepted: q.Wpenads plusbcc changestpennit application (7.2004) Revised 6.1.05 bh EAD ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER OF HE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Page 4 Date: q/1 (0 Day Telephone: o 3 . g7 & L ( • City State Zip Date Application Expires: Staff Initials: Payee: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2610000080 Address: 4825 S 145 ST TUKW Suite No: Applicant: NGUYEN RESIDENCE NORTHWEST PERMIT INC Payment Check 5216 MECHANICAL - RES RECEIPT 1 Receipt No.: R05 -01293 Payment Amount: 175.56 Initials: BLH Payment Date: 09/01/2005 11:21 AM User ID: ADMIN Balance: $0.00 TRANSACTION LIST: Type Method Description Amount 175.56 Account Code Current Pmts 000/322.100 175.56 Permit Number: MO5-131 Status: APPROVED Applied Date: 09/01/2005 Issue Date: Total: 175.56 6730 09/02 9710 TOTAL 175.56 Printed: 09 -01 -2005 4 • • • � d es D11Ii5I ON OAArisl -oe6r /J4e Ai ' 5 S. 145 5J. — r 1.4ML c /I4 givocK 10 Cat' FILE O0P1f It No. -heLali213( leView . , , is • bh errors and omiss5orte. of •, does not authorize the vloIaUort o f y Code or ordinance. Rerek* OF alippoMed i fr • ey � Date: -u,( VS Is acknowledged 41 "far VVI:D FOR CODE CON PLIANCE a o fAR n SEP - 1 2005 City Of Takwila /'gyp BI 1117 D eW.- w440A CEIVED CITY OF TUKWILA AUG 2 4 2005 PERMIT CENTER BIBIMUSW No ch sages shall be made to the ccepe of worts without prior approve! of Yokwila Building Division. u re a new p al n submittal and may include additional plan review fees. LENNOX REVIEWED FO CODE COMPLIAN An[ffal"'+ mn SEP --1 2005 02002 Lennox Industries Inc. Dallas, Texas City Of Tukwila ll�I��I�► FrcTo FILE COPY \ ----- INSTALLATION INS UCTIONS AUG 2 /4 2005 PERMIT CFNTER HSXAl2 Outdoor Unit HSXAl2 outdoor units use R41OA which is an ozone friendly HFC refrigerant. This unit must be installed with a matching indoor coil and line set as outlined in the Lennox Engineering Handbook. HSXAl2 outdoor units are de- signed for use in expansion valve (TXV) and fixed orifice systems. Refer to the Lennox Engineering Handbook for expansion valve kits which must be ordered separately. A filter dryer approved for use with R41 OA has been shipped with the unit. This component must be installed prior to op- erating the unit. Failure to install the provided filter dryer will void the warranty. I Shipping and Packing List 1 - Assembled HSXAl2 outdoor unit 1 - Liquid line filter drier (approved for use with R41OA systems) 1 - Fixed orifice refrigerant metering device Check equipment for shipping damage. If you find any damage, immediately contact the last carrier. AWARNING Improper installation. adjustment. alteration. service or maintenance can cause property damage. person- al injury or loss of life. Installation and service must be performed by a qualified installer or service agency. AIMPORTANT This unit must be matched with an indoor coil as specified in Lennox' Engineering Handbook. Coils previously charged with R22 must be flushed. 04/04 1111111 Page 1 ` 131 ::,ti''_�.; i • t:_ c- tiaisS�:: isziaa' �F,. i1? i:. a. in.-...... s.;. wtr� ..::,::.s���.:..,:n.u�:w... w: .4r t .aw�..«a,. HSXAl2 Series Units CONDENSING UNITS 504,540M 04/04 Supersedes 12/03 RECEIVED CITY OF TUKWILA Technical Publications Litho U.S.A. Table of Contents HSXAl2 Outdoor Unit 1 Shipping And Packing List 1 General Information 1 Unit Dimensions 2 Setting the Unit 3 Electrical 3 Refrigerant Piping 5 Flushing Existing Line Set & Indoor Coil 5 Refrigerant Metering Device 11 Manifold Gauge Set 11 Service Valves 12 Leak Testing 13 Evacuation 13 Start-up 14 Charging 14 System Operation 18 Maintenance 18 Optional Accessories 18 HSXAl2 Check Points 19 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE I General Information These instructions are intended as a general guide and do not supersede national or local codes in any way. Consult authorities having jurisdiction before installation. A WARNING This product and /or the indoor unit it is matched with may contain fiberglass wool. Disturbing the insulation during installation. mainte- nance, or repair will expose you to fiberglass wool dust. Breathing this may cause lung cancer. (Fiber- glass wool is known to the State of California to cause cancer.) Fiberglass wool may also cause respiratory, skin, and eye irritation. To reduce exposure to this substance or for further infort consult material safety data sheets available from address shown below. or contact your supervisor. Lennox Industries Inc. P.O. Box 799900 Dallas, TX 75379 -9900 504, 54 111 11111 lil 11 111 III II UIU I III 01 11111111111 1111 Model No. A B C HSXAl2 -018 HSXAl2 -024 in. 25 24-1/4 24-1/4 mm 635 616 616 HSXAl2 -030 HSXAl2 -036 HSXAl2 -042 HSXAl2 -048 in. 33 32 -1/4 24-1/4 mm 838 819 616 HSXAl2 -060 in. 29 28-1/4 28-1/4 mm 737 718 718 1.1.Init Dimensions`' - Inches (mm) INLET AIR INLET AIR Top View Side View 3,4 (19) • 4 2451) OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) COIL DRAIN OUTLETS (Around perimeter of base) VAPOR LINE CONNECTION LIQUID LINE CONNECTION ELECTRICAL INLETS OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) OUTDOOR COIL FAN 6-318 (162) COMPRESSOR VAPOR & LIQUID LINE CONNECTION 2-3/4 (70) 43/8 (111) (;62) (1 Top View Base Section C DI SCHARGE AIR Side View 43/8 Setting the Unit ACAUTION In order to avoid injury, take proper precaution when lifting heavy objects. ACAUTION Sharp sheet metal edges can cause installing the unit. avoid accidental sharp edges. e er to un t • men injury. When contact with ons or siz ng mount ng s a •, p at- forms or supports. Refer to figure 1 for installation clear- ances. Installation Clearances "NOTE - A service clearance of 30" (762 mm) must be main- tained on one of the sides adjacent to the control box. Clear- ance to one of the other three sides must be 36" (914 mm). Clearance to one of the remaining two sides maybe 12" (304 mm) and the final side may be 6" (152 mm). NOTE - A clearance of 24" (610 mm) must be maintained between two units. NOTE - 48" (1219 mm) clearance required on top of unit. Maximum soffit overhang Is 36" (914 mm). Figure 1 Slab Mounting When installing a unit at grade level, the top of the slab should be high enough above the grade so that water from higher ground will not collect around the unit. See figure 2. Slab should have a slope tolerance away from the building of 2 degrees or 2 inches per 5 feet (51 mm per 1524 mm). Refer to roof mounting section for barrier construction if unit must face prevailing winter winds. Slab Mounting At Ground Level structure discharge air Ji JL Mounting slab must slope away from building. I ground level Figure 2 Page 3 Roof Mounting Install unit at a minimum of 4 inches above the surface of the roof. Care must be taken to ensure weight of unit is properly distributed over roof joists and rafters. Either red- wood or steel supports are recommended. Electrical In the U.S.A., wiring must conform with current local codes and the current National Electric Code (NEC). In Canada, wiring must conform with current local codes and the current Canadian Electrical Code (CEC). Refer to the furnace or blower coil installation instructions for additional wiring application diagrams and refer to unit nameplate for minimum circuit ampacity and maximum overcurrent protection size. A WARNING Unit must be grounded in accordance with national and local codes. ELECTRIC SHOCK HAZARD. Can cause injury or death. 1 - Install line voltage power supply to unit from a properly sized disconnect switch. 2 - Ground unit at unit disconnect switch or to an earth ground. NOTE - To facilitate conduit, a hole is in the bottom of the control box. Connect conduit to the control box us ing a proper conduit fitting. NOTE - Units are approved for use only with copper conductors. 24V, Class II circuit connections are made in the low voltage junction box. Refer to figure 4 for field wiring diagram. NOTE - A complete unit wiring diagram is located in side the unit control box cover. 3 - Install room thermostat (ordered separately) on an in- side wall approximately in the center of the conditioned area and 5 feet (1.5 m) from the floor. It should not be installed on an outside wall or where it can be effected by sunlight, drafts or vibrations. 4 - Install low voltage wiring from outdoor to indoor unit and from thermostat to indoor unit. See figure 3. Model Valve Field Size Connections Recommended Line Set Liquid Line Vapor Une Liquid Line Vapor Line L15 Line Sets -018 3/8 in. (10 mm) 5/8 in. (16 mm) 3/8 in. (10 mm) 5/8 in. (19 mm) L15-26 15 ft. - ft. (4.6m -1 1 5 m) 030 -036 3/8 in. (10 mm) 3/4 in. (19 mm) 3/8 in. (10 mm) 3/4 in. (19 mm) 15 ft. - 50 ft. (4.6 m - 15 m) - 042 - 048 3/8 in. (10 mm) 7/8 in. (22 mm) 3/8 in. (10 mm) 7/8 in. (22 mm) L15-65 (4.6 m - 15 m) -060 3/8 in. (10 mm) 1 -1/8 in. (29 mm) 3/8 in. (10 mm) 1 -1/8 in. (29 mm) Field Fabricated [Refrigerant If the HSXAl2 unit is being installed with an indoor coil and line set, make the refrigerant connections as outlined in this section. If an existing line set and /or indoor coil is going to be used to complete the HSXAl2 system, refer to this sec- tion, as well as the flushing section which follows. Field refrigerant piping consists of liquid and vapor lines from the outdoor unit (sweat connections) to the indoor coil (flare or sweat connections). Use Lennox L15 (sweat, non - flare) series line sets as shown in table 1 or use field -fabri- cated refrigerant lines. Refer to Refrigerant Piping Guide (Corp. 9351 -L9) for proper size, type, and application of field- fabricated lines. Valve sizes are also listed in table 1. Refrigerant Line Connections HSXAl2 Matched with New Indoor Coil and Line Set If the HSXAl2 is being used with an existing indoor coil which was equipped with a liquid line which served as a metering device (RFC!), the liquid line must be re- placed prior to the installation of the HSXAl2 unit. If refrigerant lines are routed through a wall, seal and isolate the opening so vibration is not transmitted to the building. Table 1 Refrigerant Line Sets NOTE - Units am designed for line sets of up to fifty feet (15 m). For applications longer than fifty feet, consult the Len- nox Refrigerant Piping Guide (Corp. 9351 -L9). Select fine set diameters from table 1 to ensure that oil returns to the compressor. Installing Refrigerant Line During the installation of any heat pump or a/c system, it is important to properly isolate the refrigerant lines to prevent unnecessary vibration. Line set contact with the structure (wall, ceiling or floor) causes some objectionable noise when vibration is translated into sound. As a result, more energy or vibration can be expected. Closer attention to line set isolation must be observed. Following are some points to consider when placing and installing a high - efficiency outdoor unit: 1 - Placement - Be aware some localities are adopting sound ordinances based on how noisy the unit is from the adjacent property not at the original installation. Install the unit as far as possible from the property line. When possible, do not install the unit directly outside a window. Glass has a very high level of sound transmis- sion. 2- Line Set Isolation - The following illustrations demon- strate procedures which ensure proper refrigerant line set isolation. Figure 5 shows how to install line sets on vertical runs. Figure 6 shows how to install line sets on horizontal runs. Figure 7 shows how to make a transition from horizontal to vertical. Finally, figure 8 shows how to place the outdoor unit and line set. Outside Wal Liquid Line Vapor Line (wrapped with Arm - flex) tside Wall IMPORTANT - Refrigerant lines must not contact structure. r Wood Block Between Studs Refrigerant Line Sets How To Install Vertical Runs (new construction shown) NOTE - Similar installation practices should be used if line set is to be installed on exterior of outside wall. IMPORTANT - Refrigerant lines must not contact wall. Figure 5 Page 6 Vapor Line Liquid Line Wire Tie Inside Wall Strap Sleeve Wire Tie Wood Block Wire Tie Strap Sleeve To hang line set from joist or rafter, use either metal strapping material or anchored heavy nylon wire ties. Tape or Wire Tie Refrigerant Line Sets: Installing Horizontal Runs 8 feet Metal Sleeve 8 feet Wire Tie (around vapor line only) Strapping Material (around vapor line only) Tape or Wire Tie Floor Joist or Roof Rafter Strap the vapor line to the joist or rafter at 8 ft. intervals then strap the liquid line to the vapor line. Figure 6 Page 7 Anchored Heavy Nylon Wire Tie Wall Stud Metal Sleeve Refrigerant Line Sets: Transition From Vertical To Horizontal Strap Liquid Line To Vapor Line Vapor Line Wrapped in Liquid Line Armaflex Automotive Muffler -Type Hanger Wall Stud ' Metal Vapor Line Sleeve Wrapped in Armaflex Strap Liquid Line To Vapor Line Liquid Line Figure 7 Outside Unit Placement and Installation Install unit away from windows. Two 90° elbows installed in line set will reduce line set vibration. Figure 8 Page 8 General Model No. Data Nominal Tonnage (kW) HSXAl2 -018 1.5 (5.3) HSXAl2 -024 2 (7.0) HSXAl2 430 2.5 (8.8) HSXAl2 -036 3 (10.6) HSXAl2-042 3.5 (12.3) HSXAl2-048 4 (14.1) HSXAl2-060 5 (17.6) Connections Liquid line (o.d.) - in. (mm) (sweat) Suction line (o.d.) - in. (mm) 3/8 (9.5) 3/4 (19.1) 3/8 (9.5) 3/4 (19.1) 3/8 (9.5) 3/4 (19.1) 3/8 (9.5) 3/4 (19.1) 3/8 (9.5) 7/8 (22.2) 3/8 (9.5) 7/8 (22.2) 3/8 (9.5) 1 -1/8 (28.6) Refrigerant 1 R-410A charge furnished 3 lbs. 11 oz. 4 lbs. 2 oz. 5 lbs. 4 oz. 5 lbs. 14 oz. 6 lbs. 14 oz. 7 lbs. 15 oz. 9 lbs. 13 oz. 3 Minimum circuit ampacity (1.67 kg) (1.87 kg) (2.38 kg) (2.66 kg) (3.12 kg) (3.60 kg) (4.45 kg) Condenser Net face area - sq. ft. (m Outer 11.33 (1.05) 11.33 (1.05) 15.11 (1.40) 15.11 (1.40) 15.11 (1.40) 15.11 (1.40) 16.33 (1.52) Coil Inner - - - - - - 5.4 (0.50) 5.4 (0.50) 14.4 (1.34) 14.4 (1.34) 15.71 (1.46) Tube diameter - in. (mm) 5/16 (7.9) 5/16 (7.9) 5/16 (7.9) 5/16 (7.9) 5/16 (7.9) 5/16 (7.9) 5/16 (7.9) No. of rows 1 1 2 2 2 2 2 Fins per inch (m) 22 (866) 22 (866) 18 (748) 18 (748) 22 (866) 22 (866) 22 (866) Condenser Diameter - in. (mm) 18 (457) 18 (457) 18 (457) 18 (457) 18 (457) 18 (457) 22 (559) Fan No. of blades 3 3 4 4 4 4 4 Motor hp (W) 1/6 (124) 1/6 (124) 1/6 (124) 1/6 (124) 1/3 (249) 1/4 (187) 1/3 (249) Cfm (Us) 2200 (1040) 2200 (1040) 2430 (1145) 2430 (1145) 2800 (1320) 2785 (1315) 3790 (1790) Rpm 1100 1100 1090 1090 1100 1050 1075 Watts 180 180 190 190 310 275 370 Shipping Data lbs. (kg) 1 pkg. 136 (62) 138 (63) 157 (71) 160 (73) 185 (84) 185 (84) 214 (97) Model No. HSXAI2 -018-230 HSXAl2 -024.230 HSXAI2 4130230 HSXAl2 -036- 230 HSXAl2 -042 -230 HSXAI2 -048- 230 HSXAI2 460.230 Line voltage data - 60hz - 1 phase 208/230 208/230V 208/230V 208 /230V 208/230V 208/230V 208/230V nun Overcurrent Protection (amps) 20 30 30 35 40 50 60 3 Minimum circuit ampacity 13.8 17.8 19.4 20.2 25.7 30.5 36.2 Compressor Rated load amps 10.3 13.5 15.1 15.4 19.2 23.1 27.6 Power Factor 0.98 0.98 0.97 0.95 0.97 0.98 0.98 Locked rotor amps 51 61 72.5 83 104 134 158 Condenser Full load amps 1.1 1.1 1.1 1.1 1.9 1.7 1.9 Fan Locked rotor amps 1.9 1.9 1.9 1.9 4.1 3.1 4.1 Compressor Hard Start Kit 10J42 10J42 10J42 10J42 10J42 10J42 81J69 Compressor Crankcase Heater 90P12 90P12 90P12 90P12 90P12 90P12 90P12 Compressor Low Ambient Cut -Off 45F08 45F08 45F08 45F08 45F08 45F08 45F08 Compressor Time -Off Control 47J27 47J27 47J27 47J27 47J27 47J27 47J27 Freezestat 3/8 in. tubing 93G35 93G35 93G35 93G35 93G35 93G35 93G35 1/2 in. tubing 39 1429 39H29 39H29 39H29 39H29 39H29 39H29 5/8 in. tubing 50A93 50A93 50A93 50A93 50A93 50A93 50A93 Hail Guard 17L71 17L71 17L72 17L73 17L73 17L73 45M56 Low Ambient Kit 34M72 34M72 34M72 34M72 34M72 34M72 34M72 Mounting Model No. MB2-S (69J06) MB2 -L 69J07) MB2 -L (69J07 Base Net Weight 6 lbs. 3 kg) 15 lbs. (7 kg) 15 lbs. (7 kg) Dimensions - in. (mm) 22 -1/4 x 22 -1/4 x 3 32 x 34 x 3 32 x 34 x 3 (565 x 565x76) (813x864x76) (813x864x76) Refrigerant 15 ft. (4.6 m) length L15 -41 -15 L15 -41 -15 L15 -41 -15 L15 -41 -15 L15 -65-15 L15 -65-15 Field Fabricate Line Set 20 ft. (6 m) length L15 -41 -20 L15 -41 -20 L15 -41 -20 L15 -41 -20 - - - 30 ft. (9 m) length L15 -41 -30 L15 -41 -30 L15 -41 -30 L15 -41 -30 L15 -65-30 L15 -65-30 Field Fabricate 40 ft. (12 m) length L15 -41-40 L15 -41-40 L15 -41-40 L15 -41-40 L15 -65-40 L15 -65-40 Field Fabricate 50 ft. (15 m) length L15 -41 -50 L15 -41 -50 L15 -41 -50 L15 -41 -50 L15 -65 -50 L15 -65 -50 Field Fabricate Unit Stand-Off Kit 94J45 94J45 94J45 94J45 94J45 94J45 94J45 SPECIFICATIONS -1 PHASE MODELS ELECTRICAL DATA Data 2 Maxi HSXAl2 / Page 4 OPTIO NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. i Refrigerant charge sufficient for 20 ft. (6.0 m) length of re rigerant lines 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. SPECIFICATIONS - 3 PHASE MODELS General Model No. Data Nominal Tonnage (kW) HSXAl2 -036 3 (10.6) HSXAl2-048 4 (14.1) HSXAI2-060 5 (17.6) Connections Liquid line (o.d.) - in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) (sweat) Suction line (o.d.) - in. (mm) 3/4 (19.1) 7/8 (22.2) 1 -1/8 (28.6) Refrigerant 1 R-410A charge furnished 5 lbs. 14 oz. (2.66 kg) 7 lbs. 15 oz. (3.60 kg) 9 lbs. 13 oz. (4.45 kg) Condenser Net face area - sq. ft. (m Outer 15.11 (1.40) 15.11 (1.40) 16.33 (1.52) Coll 77 35 31 Inner 5.4 (0.50) 14.4 (1.34) 15.71 (1.46) Tube diameter - in. (mm) 5/16 (7.9) 5/16 (7.9) 5/16 (7.9) No. of rows 2 2 2 Fins per inch (m) 18 (748) 22 (866) 22 (866) Condenser Diameter - in. (mm) 18 (457) 18 (457) 22 (559) Fan 2.1 2.1 4.1 No. of blades 4 4 4 Motor hp (W) 1/6 (124) 1/4 (187) - 208/230V -3ph 1/3 (249) 1/3 (249) - 460V & 575V -3ph 67K90 67K89 Cfm (Us) 2430 (1145) 2785 (1315) - 208/230V -3ph 3790 (1790) 67K90 67K89 2800 (1320) - 460V & 575V -3ph Compressor Low Ambient Cut -Off Rpm 1090 1050 - 208/230V -3ph 1075 93G35 93G35 1100 - 460V & 575V -3ph 1/2 in. tubing Watts 190 275 - 208/230V -3ph 370 50A93 50A93 310 - 460V & 575V -3ph Hall Guard Shipping Data lbs. (kg) 1 pkg. 160 (73) 185 (84) 214 (97) Electrical Model No. Data Line voltage data - 60hz - 3 phase 2 Maximum Overcurrent Protection (amps) 3 Minimum circuit ampacity HSXAl2 -036233 208/230V 25 15.4 HSXAl2 -036163 460V 10 6.9 HSXAl2 -036-575 575V 10 5.9 HSXAl2 -048-233 208/230V 35 21.7 HSXAl2 .048463 460V 15 9.8 HSXAI2 -048-575 575V 10 7.9 HSXAl2 -060-233 208/230V 40 24.5 HSXAl2 -060-463 460V 20 12.2 HSXAl2 -060-575 575V 15 9.4 Compressor Rated load amps Power Factor 11.5 0.95 5.1 0.95 4.3 0.95 16 0.98 7.1 0.98 5.6 0.98 18.1 0.98 9 0.98 6.8 0.98 Looked rotor amps 77 35 31 91 46 37 137 62 50 Condenser Full load amps 1 0.55 0.55 1.7 0.9 0.9 1.9 0.9 0.9 Fan Locked rotor amps 2.3 1 1 3.1 2.1 2.1 4.1 2.1 2.1 OPTIONAL ACCESSORIES -MUST BE ORDERED EXTRA Compressor Crankcase Heater 67K90 67K89 18M11 67K90 67K89 18M11 67K90 67K89 18M11 Compressor Low Ambient Cut -Off 45F08 45F08 45F08 Freezestat 3/8 in. tubing 93G35 93G35 93G35 1/2 in. tubing 39H29 39H29 39H29 5/8 in. tubing 50A93 50A93 50A93 Hall Guard 17L73 17L73 45M56 Low Ambient Kit 34M72 34M72 34M72 Mounting Model No. MB2 -L (69J07) MB2 -L (69J07) MB2 -L (69J07) Base Net Weight 15 lbs. (7 kg) 15 lbs. (7 kg) 15 lbs. (7 kg) Dimensions - in. (mm) 32 x 34 x 3 (813x864x76) 32 x 34 x 3 (813x864x76) 32 x 34 x 3 (813x864x76) Refrigerant 15 ft. (4.6 m) length L15 -41 -15 L15 -65-15 Field Fabricate Line Bet 20 ft. (6.1 m) length L15 -41 -20 - - - Field Fabricate 30 ft. (9 m) length L15 -41 -30 L15 -65 -30 Field Fabricate 40 ft. (12 m) length L15 -41-40 L15 -65-40 Field Fabricate 50 ft. (15 m) length L15 -41 -50 L15 -65 -50 Field Fabricate Unit Stand -Off Kit 94J45 94J45 94J45 ELECTRICAL DAT NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 20 ft. (6.0 m) length of refrigerant lines 2 IiACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. HSXAl2 / Page 5 Model No. A B C HSXAl2- 018 -024 in. mm 25 635 24 -1/4 616 24-1/4 616 HSXAl2- 030 - 036-042 -048 in. mm 33 838 32-1/4 819 24-1/4 616 HSXAl2 -060 in. mm 29 737 28-1/4 718 28 -1/4 718 DIMENSION INLET AIR TOP VIEW LIQUID LINE SIDE VIEW i� t V � � 2 51) 3/4 (19) OPTIONAL UNIT STAND -OFF KIT (4) (Field Installed) COIL DRAIN OUTLETS perimeter of base) SUCTION LINE 6.3/6 J\ CONNECTION (162) Co NNECTION ELECTRICAL INLETS OPTIONAL UNIT STAND -OFF KIT (4 (Field Installed) Imo- C -- ►I COIUTD AN COMPRESSOR SUCTION & LIQUID LINE CONNECTION (162) ° / � \" COMPRESSOR /1 6.3/8 1 TOP VIEW BASE SECTION SIDE VIEW 43/8 (111) License Information License GENESFH37006 Licensee Name GENESEE FUEL &HTNG CO INC Licensee Type CONSTRUCTION CONTRACTOR UBI 578049915 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 18206 Address 2 01/01/1980 City SEATTLE County KING State WA Zip 981180206 Phone 2067221545 Status ACTIVE Specialty I AIR HEAT,VENTILATION,EVAPORAT Specialty 2 SHEET METAL Effective Date 9/26/1963 Expiration Date 9/1/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date CLARK, ANITA J 01/01/1980 CLARK, STEVEN T 01/01/1980 CLARK, DONALD S 01/01/1980 01/01/1980 HERRMANN, GAIL 01/01/1980 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail ; Page 1 of 3 Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: / /fortress.wa. gov /lni/bbip /printer. aspx ?License= GENESFH3 7006 09/01/2005 •