Loading...
HomeMy WebLinkAboutPermit M05-172 - LUEDKE RESIDENCELUEDKE RESIDENCE 3235 S 135 ST M05-1 72 Parcel No.: 1523049099 Address: 3235 S 135 ST TUKW Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: doc: IMC- Permit City o? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.wa.us LUEDKE RESIDENCE 3235 S 135 ST, SEATTLE WA LOVELL BEN F +LINDA L 3229 S 135TH, SEATTLE WA LINDA THORNQUIST PO BOX 2034, KIRKLAND WA Contractor: Name: WASHINGTON ENERGY SERVICES CO Address: 2800 THORNDYKE AVE W, SEATTLE, WA Contractor License No: WASHIES9710B MECHANICAL PERMIT DESCRIPTION OF WORK: REPLACING GAS FURNACE AND WATER HEATER BOTH WITH GAS PIPING. Value of Mechanical: $6,056.00 Type of Fire Protection: Furnace: <100K BTU 1 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 Permit Number: Issue Date: Permit Expires On: Fees Collected: $194.00 International Mechanical Code Edition: 2003 EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -172 Phone: Phone: 425 275 -8457 Phone: 206 282 -4200 Expiration Date:09 /02/2007 Steven Al. Mullet, Mayor Steve Lancaster, Director M05 -172 11/08/2005 05/07/2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 1 Emergency Generator 0 Other Mechanical Equipment Printed: 11 -08 -2005 City Tukwila Permit Center Authorized Signature:p4AJl.it Print Name: Signature: / kety& (1/1 ls.4 7?-ee- r7i &v!f 7-- doc: IMC- Permit Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: ci.tukwila.wa.us M05 -172 Date: Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -172 Issue Date: 11/08/2005 Permit Expires On: 05/07/2006 II I hereby certify that I have read and amined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru ion or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: � / WO This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 11 -08 -2005 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1523049099 Address: 3235 S 135 ST TUKW Suite No: Tenant: LUEDKE RESIDENCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS * *continued on next page ** M05 -172 Permit Number: M05 -172 Status: ISSUED Applied Date: 11/08/2005 Issue Date: 11/08/2005 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. Printed: 11 -08 -2005 Signature: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: (--/ f4 on- 77- it c crf ( Date: ` ` e M05 -172 Printed: 11 -08 -2005 Site Address: 23C S. / S Tenant Name: J d V) G�` c � LI l K Property Owners Name: 3 23 S ! 35 -14 S Mailing Address: 'CONTACT PERSON Name: Li h DA Mailing Address: ? O'1 )c. �o3 E -Mail Address: CITY OF TUKWILA Community Developmen. epartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 q:\\permits phu\icc changea\permit application (7.2004) Revised. 64.05 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Page I Building Perm. No. Mechanical Permit No Public Works Permit No Project No (For office use only) . King Co Assessor's Tax No.: / S 2-3 0 4 1-( 7 t 6'19 Suite Number: Floor: New Tenant: ❑ .... Yes ❑ ..No h � 4 p L,u- dims City State Zip Day Telephone: ' 2T ei� 7 S -f s -] K.Irlact frtc) City (/ _ Sta a Zip Fax Number: - 7 7 S Lo 3 / GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page Company Name: lit/ 4S 1`1(( .. t c t LL cal Mailing Address: State State State Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT. O F RECORD All plans must be wet_ stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip ENGINEER OF RECORD =. All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip • s.: aS�:..lau...... Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU / Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to I ieat/Refrig/Cool ing System Incinerator - Domestic Emergency Generator / _ _ _� G(� Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT. INFO. ./IATION - 206- 431 -3670 MECHANICAL CONTRACTOR FORMATION Company Name: wash 4-vicel Mailing �'I Address: Oc (ho i d. e-' ) �Ff _ .. t Jew &' -`- C+ 9 ✓ � =f City State Zip Contact Person: •l (. J 13 klA I Day Telephone: 2-0 Co 'j `7 106 E -Mail Address: � Fax Number: & L2i5 I 7 7 1 4s-840 Contractor Registration Number: j�1. (/ / / C73 Expiration Date: C L * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Use: Residential: New .. Commercial: New ....❑ Fuel Type: Electric ❑ Gas . Sc pe of Fork (please provide detailed • formation): C 4.f f1/12 i/l 3 r O `7O C0 a e/i-v Replacement � ` V��_� c Jff 7 !(�C CLt1�Je Replacement ❑ C-7 Sr- Indicate type of mechanical work being installed and the quantity below: Other: PERMIT APPLICATION NOTES- Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 R OR AUTHO IZED A ENT: Signature: tn Date: L �}— aY V/✓ 1 Telephone: �7 (; 1 75 - d O Print Name: Day y elephon fie 6P2 Address: e 0X a-&) / �={ l G � J ie6P2 State Zip Date Application Accepted: q:Wpermits plua cc changestpermit application (7 - 2004) Revised. 64.05 bh Page 4 City Date Application Expires: Staff Initials: i ofe,Ciaw.4444i,4 s: is '!n1..e4,AVV'sdL.4.1inLrke.:41 Receipt No.: R05 -01626 Initials: ]EM User ID: 1165 ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payee: WASHINGTON ENERGY SERVICES COMPANY Payment Check 5236 MECHANICAL - RES RECEIPT ■ Parcel No.: 1523049099 Permit Number: M05 -172 Address: 3235 S 135 ST TUKW Status: APPROVED Suite No: Applied Date: 11/08/2005 Applicant: LUEDKE RESIDENCE Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Amount: 194.00 Payment Date: 11/08/2005 11:13 AM Balance: $0.00 194.00 Account Code Current Pmts 000/322.100 194.00 Total: 194.00 9106 11/0B 9716 TOTAL 369.56 Printed: 11 -08 -2005 Project: - . ... , / Type of Inspection: / r,, 0 Address: - ' 5, 3?3..5 /3 Date Called: Special instructions: Cxe // .t 4 ''' Date Wanted: (4.1s, p".ii. Requester: Phone No: — tA= INSPECTION No. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 Approved per applicable codes. • INSPECTION RECORD Retain a copy with permit PE (206)431-3670 Corrections required prior to approval. COMMENTS: $58.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: i ..",/, e ___ Type of Inspection: /1 ...." LI.? / Address: S e-- Date Called: Special TnstruCtildhs: • 1 5 Th r) ...1 (9 Date Wanted: . 11. p.m. Requeste Phone No: 2-616-q3(9.-109' INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit COMMENTS: fr .6- Corrections required prior to approval. 6, S58.00 REINSPECTION IfE REQUIRED. Prior to inspection, fee must be paid at 6300 SouthcenteY Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: Date: 1 File: M05 -0172 35mm Drawing #1 ODS CATALOG ORDERING NO. PRICE Rated Healing Input (KTUH) Rated Healing Output (RTUII) AFUF,* 'Yo SELECTABLE COOLING CFM•rl 0.5 ESP MAX/MINt VENT DIA CASING WIDTH (1N.) APPROX SHIP. WT (LB) LIST PRICE 31UAAV24045 • 44.000 35,000 80.0 845/620 4 14 -3/16 104 829 310AAV36045 44,0110 36.000 80.0 1160/1040 4 14 -3/16 107 829 ' 310AAV24070 66,000 53.000 R0.0 900/600 4 14 - 3/16 • 111 1000 310AAV36070 66.000 54,000 80,0 1200/1050 4 14 - 3/16 115 829 . 310AAV42090 88,000 71.000 80.0 13145/1195 • 4 17 -1/2 127 1050 • 310AAV48090 88,000 71.000 80.4) 1720/1375 4 21. 140 882 •310AAV36110 * 110,000 89,000 80.0 _ 1355/1080 4 , 17 -1/2 135 1116 310AAV48110 110,000 89,000 80.0 1680/1310 4 21 146 1163 3.10AAV66110 110,000 89,000 80.0 • 2220/1795 4 '• 21 152 '1000 ' 310AAV48135 132,000 107.000 80.0 1710/1380 50 21 149 1245 .310AAV66135 132.000 107,000 80,0 2110/1715 50 .24 -1/2 163 1087 310AAV66155 154,000 125,000 80.0 2230/1695 5a 24 - 1/2 170 1406 OPTIONAL EXTENDED WARRANTIES PRICE Parts Only — 2" through 5 year Parts Only — 6'" through 10 year (requires 2" through 5 year putts) Parts and Labor — 2"" through 5° year Parts and Labor -- 6 through 10 year (requires 2 "' through 5 year parts and labor) (Important — Sec optional warranty literature for full details and requirements) See Residential Warranty Price Sheet DESCRIPTION PART NO. LIST PRICE Twinning Kit KG ATWt1601HS1 190 Natural -to- Propane Gas Cnnvcr Kit (Single Kit) KGANP2901ALL 226 C.01110 110 ama CIT OF N�KVVM NW' - 8 2005 PERMIT CENTER • Capacity and rotuarla in acco dance with U.S. GovcannmL 1K)16 test procedures with isolated cnmhuainn system, + Listed CFM iv 1'w Angle-speed cooling, • 4 inch venL cnnneerion in MI furna et 310AAV-: _10- 22- 04.DOC • t'_`1 t •m - tSIMM t`e e! t e••• 1® awa —.� .,,■,•tea... WaShingbOtt EnergySeravices- 310AAV 4 -WAY MULTIPOISE GAS FURNACE The 310AAV 4 -Way Multipoise Gas Furnace was designed by Bryant dealers for Bryant dealers. Applications arc easy with 4 -way ntultipoise desigt, through. the furnace dtrwnflow venting, 13 different venting options, and a door designed for easy service access. An inner blower door is provided for tighter scaling in sensitive applications. The 310AAV furnace is approved for use with natural or propane gaff. STANDARD FEATURES • Noise elimination combustion system • Four position furnace: upflow, horizontal right, horizontal left, clowntlow Thirteen different vent options • Shorter hi height — only 33'/" tall • Microprocessor based control center Adjustable heating air temperature rise T.111) diagnostics and self test feature Patented blocked vent safeguard to ensure proper furnace venting All models are Chimney Friendly when used with accessory vent kit Heat pump compatible • • • • Hot surface ignition (RSI) • Residential installations eligible for consumer financing through the Comfort Credit Program LIMITED WARRANTY • 20 -year warranty on "Super S heat exchanger • 5 -year parts warranty on all other components FURNACE ACCESSORIES .. _ • rage; L OT 0 APAPVIMINIMM e rw r adiringt°n ligiai l i , Aki 7 4 C11M D Equipment.& Labor Prices Oefv OP TUKWILA THIS PAGE MUST BE INCLUDED WITH INSTALL INSTRUCTIONS 1 ""NO EXCEPTIONS'" B Vent Water Heaters PERMIT CENTER No Heat? (please circle) Yes or No y • : u 7 (ti r �r A3 nif • ,. Irli � � � ''•' ';!''' (i. •iiili ' k ` ... J.. =:: ` •• -''' .' �`,_ y:• " '�}r Retail Price Sales Charge Pre - pricing P.1' {.Il f 1T• l�nl tC.�11Y1n 7 m� VI !►S_ :.�fF'iw!:.;- 2121 ??,`.1 22V3030F -15 3/4" x 59" Energy Miser I /l1UrN, ILYI �r."�r�n 1 °wln q_ql .• 'P 11[Xi- 011ltl11i1 1 'u`':__:i i9111( 111W�a'ist :NYu:;;iIfltf,'1:if MIf G Burltlttl�ld I 30Gal 328TU6 Yr $621 42V4040F -17 3/4" x 60" Energy Miser 40Gal 38BTU6 Yr $548 42V5040F -19 3/4" x 61" Energy Miser 50Gal 4OBTU High Boy6 Yr $605 42VR4040F - 21" x 81 3/4" HI -Eff 40Ga1 .6 408TU6 Yr $557 42XR4040F - 21" x 61 3 /4 "Hi- Efficiency 40Gal .6 4OBTU10 Yr $605 42VR5040F - 23" x 60 3/4" Hi-Eff 50GaI.6 4OBTU6 Yr $824 42XR5040F - 23" x 60 3/4" HI- Efficiency 50Ga1.6 40BTU10 Yr $633 AGCVX50 (A.O. SMITH 21V506A REPLACEMENT) - 23" x 63 1/2" Hi- Recovery 50Gal 6OBTU (4" flue)6 Yr $793 42V40S40F -19 3/4" x 52 1/2" Engy Msr 40G 4OBTU LO-BOY (Stubby) 6 Yr $648 AGCLV50 (A.O. SMITH 41 V5OS REPLACEMENT) - 22 1/4" x 54" Engy Msr 50G 4OBTU R20 (Stubby) 6 Yr $776 22VR7570NT - 26 1/4" x 64 1/2" Hi- Recovery 75GaI.6 75BTU (4" flue )6 Yr $1,055 ?1V100 -- 26 1/4" x 68" Ni- Recovery 1000a1 .6 75BTU (4" flue )6 Yr $2 195 � n•i r f s�!! ; 0�q i yy h1 1 li I r i _..: .: .:r li 1 (h�{ �ii•�ppi {i. �' 1( [ - 10i li _::.1 I -:_:� Alt!` i r' �T1- ,. :S 1'+ �,, ..•.Il`f{�,: ILILI'+ Yuiiu.; t.:Iq+{ilNuluc.,19D1uGN:w,.r11_ �lil:, Gil ?idllh"ra.;'!�4UU:�!yWNx��''` -! ',Bill {IIIIM:�1L�IIIG,' 1 Base Price (all applications) - (includes 25' of copper lines) $314 Optional Standard Items; Elevate $83 Expansion Tank $138 Vehicle Post 5121 Combustion Air (2 sided) $171 Optional Add -On's; „ Gas Pipe Set U • Fee one charge per'ob . $242 Gas Pi • e Foote • e# X $4 per Foot = Water Line Footage* X $9 per Foot (includes insulation) (where required 13 -Vent Footage #__ . X' $20 per Foot Jack $193 , Roof _ Concrete Coro 3" or 6" hole $198 LAINACT303B7W - Auto Clr Pump (need ele out w /in 3') $605 Provide 110V electrical outlet (within 3' of equipment) S242 ALPHQV100 - Earthquake Valve $358 Additional Labor _ Total Labor transferred to Contract Total Permits transferred to Contract • Water; _Heaterprice pages110.22- 04 -05 -2007 LINDA THORNQUIST PO BOX 2034 KIRKLAND WA 98083 RE: Permit No. MO5 -172 3235 S 135 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/04/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 4,4( Jc'ndfer Marshall, Permit Technician xc: Permit File No. M05 -172 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431.3670 • Fax: 206 - 431 -3665 October 26, 2006 Kina Cul lop Washington Energy Services 2800 Thorndyke Ave W Seattle WA 98199 RE: Request for Extension Mechanical Permit No. M05-172 Luedke Residence — 3235 S 135 St Dear Ms. Cul lop: This letter is in response to your written request for an extension to Permit No. M06-172. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 180 days from the date of your request (through May 4, 2007) as requested. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Yl- arshall hnician City of Tukwila Department of Community Development Steve Lancaster, Director File: Permit No. M05-172 P:VenniferTatension Letters \Familia \MD5-172 Permit Extension.doc jem Steven M. Mullet, Mayor Page I of I 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 •=122222121===11,,, 10/25/2006 WED 14i35 FAX 206 378 6600 Washington Energy Oval. 5/ sr0 6 ATTN: Permit Technician I Kina Cullop of Washington Energy Services am requesting that the Mechanical permit for site address 3235 S 135th St—Jonathon Leudke, be extended. The extension is necessary because we need to order an electrical permit and have it pass inspection in order to pass a final mechanical inspection, and we will not be able to accomplish that in the time that is left. I appreciate your attention to this issue. Thank you, Kina Cullop Washington Energy Services Permit Coordinator 206-378-6649 FAX: 206-378-6600 ;!■,: .. • k_ • e/. (DI A . 9 217 1 r)4C ( • •:.;. RECEIVED CITY OFTHKWCA OCT 2 5 2006 PERMITCENTER AA, Dc - 1 1 616+: lo4101— 2001/001 10 -03 -2006 LINDA THORNQUIST PO BOX 2034 KIRKLAND WA 98083 RE: Permit No. M05 -172 3235 S 135 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the°International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null.and void if the building or work authorized by such permit is' not commenced within 180..days from the date of such permit, on if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine: if substantialwork has been accomplished since issuance of the permit or last inspection; or-if the project should be considered abandoned. If such determination is made; the Building:Code does allow the Building Official.to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 11/05/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, rshall, Permit'l'e6hnician xc: Permit File No. M05 -172 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206. 431 -3665 meemegamfimanimannamameggnommegengenr 04 -03 -2006 LINDA THORNQUIST PO BOX 2034 KIRKLAND WA 98083 RE: Permit No. M05 -172 3235 S 135 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any 'time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one or more extension of time for additiona perios not exceeding 90 days each. Extension requests must be in writini' and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/07/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ife arshall, Permit Technician xc: Permit File No. M05 -172 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director • 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431.3670 • Fax: 206 - 431 -3665 License Information License WASHIES971OB Licensee Name WASHINGTON ENERGY SERVICES CO Licensee Type CONSTRUCTION CONTRACTOR UBI 602320560 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 2800 THORNDYKE AVE W Address 2 City SEATTLE County KING State WA Zip 98199 Phone 2062824700 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 9/2/2003 Expiration Date 9/2/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date OLSON, CRAIG PRESIDENT 09/02/2003 HEAGLE, RANDY SECRETARY 09/02/2003 CHRISTIANSON, STEVE TREASURER 09/02/2003 OLSON, VERN VICE PRESIDENT 09/02/2003 Look Up a Contractor, Electri^an or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information I Bond I Bond 1 I I I https : // fortress. wa. gov /lni/bbip /printer.aspx ?License= WASHIES971 OB 11/08/2005 File: M05 -0172 35mm Drawing #1 A 1 1III1III11II1111i Ill IIlII1 II1111111 111111111111111 IIIIIII 111+111 Inch 1/16 41 51 1 6 1 i ? aM vI L 911. b � 1 z� L 6 u } >:+.,Q � ; :.., I I I 1 1111 I_llll I s I I I I I I ll I I I I I I I I.LI.I I I I I I I I I I I I t 1 I I I I I I I 1 b I I 1 11.1 I I I 8 f I I I l I l l IIII ... I IIIIIIIILLLII111111111I111111111I1111111111111111III111111111111111 X05 - r�-2 ern OF NOV - PERMIT CENTER