Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M05-179 - DUGGER RESIDENCE
DUGGER RESIDENCE Parcel No.: 0041000605 Address: 4053 S 151 ST TUKW Suite No: Tenant: Name: DUGGER RESIDENCE Address: 4053 S 151 ST, TUKWILA WA Owner: Name: DUGGER CRAIG W +MONICA M Address: 4053 S 151ST ST, TUKWILA WA Contact Person: Name: TODD EVANS Address: 7649 S 180 ST, KENT WA Contractor: Name: PERFORMANCE HEATING Address: 7649 S 180 ST, KENT WA Contractor License No: PERFOHA15ORT DESCRIPTION OF WORK: CHANGE OUT EXISTING GAS FURNACE Value of Mechanical: $3,700.00 Type of Fire Protection: Furnace: <100K BTU 1 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC- Permit City 6 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -179 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 251 -0356 Phone: 425 251 -0356 Expiration Date: 04/29/2007 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -179 11/16/2005 05/15/2006 Fees Collected: $167.25 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 11 -16 -2005 Permit Center Authorized Signature: / V11qt JUG4 \ I hereby certify that I have read and eta ninel t is permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC- Permit City OA Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.wa.us Cif hanl -� tre\ ■ M05 -179 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -179 Issue Date: 11/16/2005 Permit Expires On: 05/15/2006 Date: 1f1Git'( Date:' k\\j I (p t 0 Printed: 11 -16 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0041000605 Address: 4053 S 151 ST TUKW Suite No: Tenant: DUGGER RESIDENCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Conditions PERMIT CONDITIONS * *continued on next page ** M05 -179 Permit Number: M05 -179 Status: ISSUED Applied Date: 11/16/2005 Issue Date: 11/16/2005 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. Printed: 11 -16 -2005 O 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the 2 Building Official. u - 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to - a • start of any construction. These documents shall be maintained and made available until final inspection approval is w granted. ' z F- O 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. Ui ? . 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances 8 shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, o '— bathrooms, toilet rooms, storage closets, surgical rooms. = 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE u_ GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that iii z the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. v_ 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall z be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. tkaym Mr\cth1 U - +T11c-e/v) of law and ordinances other work or local laws Date: NU , N M05 -179 Printed: 11 -16 -2005 Site Address: V•353 t. /5 S-t Tenant Name: dh t t & b t! (, (,'!f Property Owners Name: 0 016 b vG 6-er Mailing Address: / Q ci s • ( 5" I jr Name: 7'1Y .E»') Mailing Address: E- Mail .Address: E -Mail Address: `appl(catiom application (7 -2004) CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 A . , lications Applications will Sn„ qS c CompanyName:• re1 F0ft. fh n wet 14 t^ Mailing Address. 74y e i Ck S' Contact Person:. "7 b eve A) be accepted through th * *Please Print ** Page 1 VJ "IIAI' /11 t Vu Building Permit No. Mechanical Permit No. Public Works Permit:No:. Project No;. .... For o/e muse on King Co Assessor's Tax No.: 60 Y/ Gero 6 U Suite Number: 7vtl.rt City New Tenant: ❑ Yes Day Telephone: City ww- State State 2-fJal State State Floor: �..No wo g Zip Zip Fax Number: RINFORMA'. Mechanical Contractor information on;backpage ILci -r lx 03 Z City State Zip Day Telephone: 92 r 2 f / - 035 Fax Number: i f Zr ZS� O? $ Contractor Registration Number: eft FG N / i > /2-T Expiration Date: t / * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Company Name: Mailing Address; City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip GINEE RD -: Allplans; mutt; be wet: stamped by Eaglneeri of .Record Company Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU ) Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Other Mechanical Equipment MECHANICAL'PERNIIT INFORMATION :206-431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: e i12 r C o - J''1 it- T if E 1i W C. Mailing Address. - 7 (0(f I S / O C) e et T W 0 T rj3 Z- City State Zip Contact Person: T t R'`"'> Day Telephone: / r Z 5-1 -0 3 OP E -Mail Address: Fax Number: 1 / 2 U r 2 4 1 — c l ° G� Contractor Registration Number: Pd t: N F' I ) A Expiration Date: // `l/ 437 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 376 D Scope of Work (please provide detailed information): C1/1 )-t..... D - -- a ( ..13 Goo 4s, fitA N- cem Residential: New ❑ Replacement mr Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: PRRMIT APPILICATION NOTES— Applicable to alI ermits ip::this;:a Value of Construction - all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN UT�hORIZED AGENT: Signature: ' /�� f Date: l / — ir °s 2T / — a3f L Print Name: TO) )) 119 Mailing Address: 7 6 C r S rir 1)1; Date Application Accepted: 11 ILUICC 'applicationa'pennit application (7.2004) Date Application Expires: Page 4 Day Telephone: krn City cg /IL tt lication f t/ eit ,t State Zip Staff Initials: 1 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 0041000605 Permit Number: M05479 Address: 4053 S 151 ST TUKW Status: PENDING Suite No: Applied Date: 11/16/2005 Applicant: DUGGER RESIDENCE _ Issue Date: Receipt No.: R05 -01668 Payment Amount: 167.25 Initials: 7EM Payment Date: 11/16/2005 01:51 PM User ID: 1165 Balance: $0.00 Payee: PERFORMANCE HEATING & AIR CONDITIONING, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 80133 ACCOUNT ITEM LIST: Description MECHANICAL - RES doc: Receipt 167.25 Account Code Current Pmts 000/322.100 167.25 Total: 167.25 9357 11/16 9716 TOTAL 107.25 Printed: 11 -16 -2005 Project: \) �( . Q.Q . Type of Inspection: I Add a s: r-/ c- I4 S , /'s ._9'`, Date Calle 1 �'),'� j05 Instructions: Special tructions: Date Wanted: � '' ( IIOS P.m. Requester: t , ll�L��( Phi a No::�� vy „ ..-)Li ee INS ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: (Rec Ipt)Ao.: INSPECTIONS RECORD Retain a copy with permit ?M;+ £7&wi Corrections required prior to approval. PER (206)431 -3670 � Date: eAANA.•4, /AA -L , 'l 8.0 REINSPECTION FEE RE IRED. Pri to inspection, fee must be aid 6300 Southcenter Blvd., Suite 100 Call to sechedule reinspection. 'Date: Project: Ty e;of Inspection: 9 z o Address: 0 - 0s -- s it f S (f. Date Called: : ,.' Special Instructions: ,b-t-4, n e 00 Date Wante u:�` c � t' /0.-, P.m. Requester: ti ca o: Requester: Phone No:, ‘ , , INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION; RECORD Retain a copy with permit (rl)5 —I"19 El Corrections required prior to approval. COMMENTS: REINSPECTION F E REQUIR D. Prior to Inspection, fee must be paO at 6300 Southcenter Ivd., Suit 100. Call to schedule reinspection. )R caI'Pt No.: 'Date: • TRANE® . 1 1‘ •'!/ '1, I 1 1 ', 31 . r: .. .. ',1 ,14.,,, -. .,., • ,,,,.,,1 1 41 ca i')• 5. , .g-tiYri '1.... • ....la-, ...1. - f 1 ,i .....17:4,7 '1‘ • • 7 ' ......■;`'• " 1 4:1 . .i.: 4 N'•••1 . . 7 . .. , f4., ,:: ,, i ! 4;: 1 r 1 . -,-,-:;,. ::i : ,s' .i :., , i -try, ;..,, :2 . XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer • .t • ti • 1,t t i .e ! ,,, • xr4 ,] :1;1 .1 /ge, CF. 1, .1 • ( 1. irrnic;In PERMIT CENTER • I ••, ).; • • '4:a 1 • ..1 •'.1. 4 1 ,, ..rwo RECEIVED CITY OF TUKWILA NOV 16 2005 PUB. NO. 22-1705-02-1202 (EN) vammossmetereFonseMESEMISIMIS • • • • MODEL RATINGS® 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS)® 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS)® AFUE (ICS) Temp. Rise (Min: Max.) °F. BLOWER DRIVE Dia: Width (In.) No. Used Speeds (No.) CFM vs. In. w.g. Motor HP RP.M. Volts/Ph/Hz COMBUSTION FAN — TYPE Drive - No. Speeds Motor HP - RPM Volts/Ph/Hz FL Amps FILTER — Fumiahed? Type Recommended Filter (No: Size -Thk.) VENT— Size (In.) HEAT EXCHANGER Type -Fired - Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size LP. Gas Qty. — Drill Size GAS VALVE DIRECT IGNRION DEVICE Type BURNERS —Type Number POWER CONN. — V/Ph/Hz0 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DUCT CONN. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.)/Net (Lbs.) 22 (EN) TDX060R936V 39000 52000 65000 36000 48000 60000 60000 80000 100000 55000 74000 93000 92.0 92.5 93.0 35.65 35.65 45 -75 DIRECT 10x8 1 4 SEE FAN PERF. TABLE 1/3 1075 115/1/60 CENTRIFUGAL DIRECT - VARIABLE 1/15 - 5000 115/1/60 1.1 YES HIGH VELOCITY 2- 14X20X1 2 ROUND ALUMINIZED STEEL TYPE 1 20 3 -45 3 -56 REDUNDANT - TWO STAGE HOT SURFACE IGNITER IN -SHOT 3 115/1/60 9.1 15 0.50 SEE OUTLINE DRAWING HXWXD 41-3/4 X 19-1/2 X 30 -1/2 SEE OUTLINE DRAWING 160/145 General Data TDX -R Product Specifications O TDX080R942V DIRECT DIRECT 10x8 11x10 1 1 4 4 SEE FAN PERF. TABLE SEE FAN PERF. TABLE 1/2 1/2 1075 1075 115/1/60 115/1/60 CENTRIFUGAL CENTRIFUGAL DIRECT - VARIABLE DIRECT - VARIABLE 1/15 - 5000 1/15.5000 115/1/60 115/1/60 1.1 1.1 YES YES HIGH VELOCITY HIGH VELOCITY 2- 14X20X1 2- 20X20X1 2 ROUND 2 ROUND ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 20 4 -45 4 -56 REDUNDANT - TWO STAGE HOT SURFACE IGNITER IN -SHOT 4 115/1/60 11.4 20 0,50 SEE OUTLINE DRAWING HXWXD 41.3/4 X 19.1/2 X 30 -1/2 SEE OUTLINE DRAWING 168/158 7 TDX100R948V 20 5 -45 5 -56 REDUNDANT - TWO STAGE HOT SURFACE IGNITER IN -SHOT 5 115/1/60 12.5 15 0.50 SEE OUTLINE DRAWING HXWXD 41 -3/4 X 23 X 30-1/2 SEE OUTLINE DRAWING 185/175 TDX120R960V 78000 72000 120000 111000 92.5 45 -75 DIRECT 11 x 10 1 4 SEE FAN PERF. TABLE 3/4 1075 115/1/60 CENTRIFUGAL DIRECT - VARIABLE 1/15 - 5000 115/1/60 1.1 YES HIGH VELOCITY 2.16X20X1 3 ROUND 20 6.45 6.56 REDUNDANT - TWO STAGE HOT SURFACE IGNITER IN -SHOT 6 115/1/60 12.9 15 0.50 SEE OUTLINE DRAWING HXWXD 41 -3/4 X 26-1/2 X 30-1/2 SEE OUTLINE DRAWING 206/196 ® Central Furnace heating designs are certified by AGA and CSA, ® For U.S. applications, above Input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level, ® Based on U.S. government standard tests. 0 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. VENT LENGTH TABLE ALTITUDE MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NOTES) 0-7,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE UX/DX060R936 200 200 200 UX/DX080R942 50 120 200 UX/DX100R948 Not Allowed 60 200 UX/DX120R960 Not Allowed Not Allowed 200 7,000 -9,500 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE UX/DX060R936 100 100 100 UX/DX080R942 25 60 100 UX/DX100R948 Not Allowed 30 100 UX/DX120R960 Not Allowed Not Allowed 100 9,500- 12,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE UX/DX060R936 50 50 50 UX/DX080R942 Not Allowed 30 50 UX/DX100R948 Not Allowed Not Allowed 50 UX/DX120R960 Not Allowed Not Allowed 50 NOTES: * - First letter may be "A" or "T" 1. Minimum vent length for all models: 3' horizontal and vertical. 2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Except adapters at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to the maximum length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a larger diameter, but never smaller than the vent pipe. 3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS THE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes). 4. One SHORT radius 90° elbow is equivalent to 10' of 3" pipe and one LONG radius elbow is equivalent to 6' of 3" pipe. One 90° elbow is equivalent to 7Y2' of 2 pipe or 5' of 2" pipe. Two 45° elbows equal one 90 °elbow. 5. The termination tee or bend must be included in the total number of elbows. If the BAYVENT100A termination kit is used, the equivalent length of pipe is 5 feet. BAYVENT200A/B equivalent length is 0 feet. 6. Pipe adapters are field supplied (except 120). MINE' Maximum Vent Length Table Timm Field Wiring ",', *17,a,-.7.,"• . AN HUMIDIFIER I." WN EAC i SR EC NOTE 5 Field Wiring Diagram For Single Stage Heating/Cooling (Outdoor Section Without Transformer) NOTES: POWER SUPPLY ■ AIR CONDITIONING OUTDOOR UNIT 1411 THOU( 1RANSFORNER1 T • GROUND . SERE" �— FURNACE • JUNCTION BOX NT I ! . — I') N -1J 11.3 I I 1 11/2 1 I I 1 1 � � I. BE SURE POTTER AGREES 111TH (05111ENT RA40101E151. 2. L08 VOLTAGE 124V. WIRING) TO BE N0. 18 0.0.0, MIN.. 1. GROUNDING OF EQUIPMENT MUST C0MPL1 111111 LOCAL CODES. 4. SET THERMOSTAT HEAT ANTICIPATOR PER ONI1 MIRING DIAGRAM. 5. THESE LEADS PROVIDE 115 V. POTTER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND NUM10121ER MAI. LOAD 1.0 AMPS EACH. E. THIS CONNECTION IS 0N11 USED FOR !HEMOSTATS REQUIRING CONNECTION 10 THE 21 V. POTTER SUPPLY. ICOMNONI 1. SEE WINNING CONNECTION DIAGRAMS FOR PROPER CONNECTIONS 8HEN USING THIS TIMOR. 8. 1HE 'T' TERMIN1NAl FROM THE TH(RN05TAT MUST RE THIRD 10 THE 1 0 . 1(RNINAI OF THE FURNACE CONTROL FOR PROPER BLOTTER OPERATION DURING COOLING. 5. 81 AND 82 MUST BE MOOED TOGETHER TOR PROPER OPERATION. SECOND STAGE HEATING MILL BEGIN 10 MINUTES AFTER FIRST STAGE. FURNACE INTEGRATED FURNACE CONTROL THERMOSTAT TERMINALS Di0v0© laaoj0000 1 1111 MINIM EE NOTE 7 FIELD ADOE JUMPER !NOTE 51 Y THERMOSTAT I STAGE HEATING 1 5TAGE COOLING WITH FAN SWIICH SEE NOTE 8 SEE NOTE 6 INTER•COMPONENT WIRING 2 R V. I FACTORY — • — • — • 0N0 0.111111110 24 V. I FIELD 0N , v. _1 RING From Dwg. 218341335 Rev. 0 ON rl 1M / 3:I I MN HUMIDIFIER eR MN EAC SR 4 =::S . EE NOTE 5 Field Wiring Diagram For Two Stage Heating/Single Stage Cooling (Outdoor Section Without Transformer) NOTES: POWER SUPPLY • IQ , :IR CONDITIONING :UTDOOR L'hlf 'WITHOUT TRANSFORMER* 1 i GROUND I scREW FURNACE 7 : JUNCTION I (-- ' BOX RR I ' Fy/1 , I ! IN ' I INTEGRATED FURNACE CONTROL THERMOSTAT TERMINALS FURNACE THERMOSTAT 2 STAGE HEATING I STAGE COOLING TTITN FAN SNITCH e 0 1 Y ]7-E) SW 412 0 `J ® (!) SEE NOTE 6 I � 4' I. BE SURE POWER AGREES WITH EQUIPMENT NANPLATEISI. 2. LOW VOLTAGE 1218. WIR11101 TO BE N0. 18 A.W.G. MIN.. 3. GROUNDING OF EQUIPMENT RUST COMPLY WITH LOCAL 000E5. 4. SEE THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 5. THESE LEADS PROVIDE 11$ V. POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER NAT. LOAD 1.0 AMPS EACH. 6. THIS CONNECTION IS ONLY USED FOR THERMOSTATS REQUIRING CONNECTION 10 THE 21 V. POWER SUPPLY. (COMMON) 7, SEE TWINNING CONNECTION DIAGRAMS FOR PROPER CONNECTIONS WHEN USING THIS FEATURE. 8. THE '1' TERMININAL FROM THE THERMOSTAT MUST BE 'WIRED 10 THE '1' TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING. ' —SF0 401E e INTER•COMPONENT WIRING 1/ V. _I FACTORY - — - — LINE v. _I WIRING 84 V. I FIELD 1111E v, I WIRING From Dwg. 218341334 Rev. 0 } • 6 JU; 0O N W' . 0 w W o ' g 4 0; • Z 11J ut O BI . 0 W O1. • Z • 11J c o, 'O 1 • Z TABLE "A" SPEED TAPS FOR I.D. FAN MOTOR MODEL HI HEAT LOW HEAT PARR •0X0 60R936Aa BL RD fL •D%080R9241 W I BL I RD I YL ' •0 %100R94814 I BL I RD I 01. •D%120R9601 BL I ?D :L ■ MAT DE ?REFIY "" OR •A" ■■ MAI EE SUFFIX "r" OR "N' RD : LOW SPEED .51 : MD. LOW SPEED 3L : TIED. :NIGH :PEED OX : HIGH SPEED TRANS' Legend LEGENO•COUIPMENT DIAGRAM to 1t r 1, . }FACTORY WIRING u -• -M V. }FIELD WIRING - • -IINf v. • — L EARTH GROUND CHASSIS GROUND • JUNCTION Q WIR( NOT OR CONNECTOR -4- -COIL -M•- CAPACITOR TRANSFORMER 0-F0 TEMP. ACTUATED SWITCH o TO PRESS. ACTUATED SWITCH c 000W SNITCH ▪ MANUAL RESET r THERMAL SWITCH w•0 FUSE 0 TERMINAL 01.01 OF WINE SLACK Inn MN 0 IR SLUE MARKER GRID OLDS 01 MANNER BR GLACE OR ORANGE IL YELLOW BE BLUE RD RED OR GREEN BR BROWN NH WHITE PR PURPLE C Cf GAS V CllAPA FAN CAPACITOR GND GROUND LVTB LIRE VOLTAGE TERMINAL BOARD N N NEUTRAL TCO HIGH TEMPERATURE LIMIT SWITCH TNS TRANSFORMER HI HI FIRE. SECOND STAGE LO LOW FIRE. FIRST STAGE B/C COMMON LPS /PSI PRES. SW. INPUT. FIRST STAGE HPS /P52 PRES. SW. INPUT. SECOND STAGE NLI NIGH LIMIT INPUT KO NIGH LIMIT OUTPUT FP FLAME SENSOR PROBE MOH GAS VALVE. HIGH. SECOND STAGE MVL GAS VALVE LOW. FIRST STAGE MV GAS VALVE. COMMON FR SAM AC TRANS. COMMON SIDE TH TO AC TRANS. HOT SIDE T 5 THERMALLY PROTECTED INTERNALLT NOTES: Electrical Data Schematic Diagrams For Gas Furnaces TDX060,080,100,120R CF BB BR RJ '5• 'C' 11 MMI., I I so MO LIM GO IUI II /5 6111 6111 —11/1 AO /S TCO•e r 0 0 0 AUN UNIT SWITCH to SEE TABLE 'A" � ▪ o et I P D I, IF ANT OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MOST BE REPLACED. IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. 2. THERMOSTAT HEAT ANTICIPATOR SETTING: FIRST STAGE .E5 AMPS. SECOND STAGE .I7 AMPS. IF SETTING IS NOT TIIED ON THERMOSTAT. FOR SINGLE STAGE HEATING THERMOSTAT SET AT .51 AMPS. J. THESE LEADS PROVIDE 120V POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER, MAR. LOAD 1.0 AMPS EACH. A JUMPER WI AND 02 FOR TINGLE STAGE HEATING THERMOSTAT. SECOND STAGE WILL BE ENERGIZED 10 MINUTES AFTER A CALL FOR NEAT. 5 FOR PROPER OPERATION OF COOLING FAN SPIED. •T' TERMINAL MUST BE CONNECTED 10 ROOM THERMOSTAT. 6. PONES GUST DE OFF WHEN DIP SWITCHES ARE SET. I WHEN TWINNING TWO FURNACES. BOTH UNITS MUST OE CONNECTED TO THE SAME 115VAC PHASE. CONNECT 1NE 2 UNITS TWIN TERMINALS WITH IA TO 22 MG. MIS VOLT 60 H2. MPH. POWER SUPPLY PER LOCAL CODES —elll DO --- Op -- - � DOOR SWITCH INTERLOCK F RD/4 NNII NN NH /1 WHYS NOTE 7 ern 131/5 NOTE NOTE 7 BRA2 RATA BEII Al 'C FLAME S ENSOR � GP 9L RDIA HI i COOL OTT Ono EC ' sof ID OTT O •T1T aT 01111 11000.011 SI X D 0. at u a a MIS all al ON . 1111011 0(1111* OFF 0 1 2 a. I 91tj 0I11C SI �NN /6 TORT S JUMPER � -0- I I OlDENI Rh I© 010 0 0 0 0I III% Ir 11 IT II 3 TO THERMOSTAT TEE NOTES 2.1,0 MPORTAMI ATEGRATED CONTROL S FOLANITI :ENSIIIUS. OF RIG Cr I /0V. ;OAER SORT MUST COVMECICD TO I +E PLACN IWAER LEND AS "DICKIES ON AIRING OIAUMAN. INDUCER HOUSING LIMIT SI. ICO•C BR /6 --OHO— BAIe HPSIPS2 O-BA HI•FIRE PRESSUR SWITCH 1C ?— 01 LO•FIRE PRESSURE LPSIPSI SNITCH I III IT SWI TCD SCO•A •ASAI 11511 RIM Natal SIIRI IL/3 rL/2 OAR MY( IIMPORIAMI: INTEGRATED FORMA ( CONTROL REPLACEMENT MUST BE AU ROMEO O.E.M. PART ONLT 15 A FUSE From Dwg. 21D341250 Rev. 0 r MODEL (SEE ROTES I) A 8 C D E _DX060R936. _DX080R942' 17-1/2' 2-1/4" 16-1/4' 16' 9' _DXI00R948. 21" 2 19-3/4" 19-1/2' 10' _DX120R960 24 -1/2' 2-15/16" 23-1/4" 23' 10" - 5/8' Ij C l_ 4-1/8 -9/16" - -6" - 19 -5/8" 4 HORIZONTAL CONDENSATE DRAIN I -7/8" X 7/8" SLOT KNOCKOUT 1/2" 5/8 r INLET AIR 7 -3/8" 5 3 -3/8" OUTLET AIR 3/4" 3t4 " -� 19'— --28 I/2' 1/2' 2" DIAMETER FLUE CONNECT SEE NOTE I 3" OPENING AIR INTAKE ,'\ 5 f� 7/8 DIA.HOLE \ 2.I/8 �I ELECTRICAL \ SUPPLY I-I /2 "DIA. HOLE GAS CONNECTION (ALTERNATE) KNOCKOUT 3 -718" 17-I/4" 10 " 12 -3/8" 1 CONDENSATE DRAIN 1 -5/16 DIA. N.O. TDX -R Outline Drawing (All dimensions are in inches) HORIZONTAL APPLICATION (THIS SIDE ONLY) I /2" 2 -1/8" 3" CONNECTION AIR INTAKE 1 - 1/2" DIA. GAS CONNECTION 20-1/4" " I MODELS DIFFERENT TO LENGT S H TAD E FOR PROPER APPLICA11011. + SUFFIX HUMBER MAY BE "V ", 0 T11RU 9 7/8" DIA. HOLE ELECTRICAL CONNECTION (ALTERNATE) KNOCKOUT 7/8" DIA. HOLE ELECTRICAL CONNECTION (ALTERNATE) 31' 7 -3/8" 2 -1/16" 3 -3/8" CONDENSATE DRAIN I -1/8" DIA. K.O. MINIMUM CLEARANCE TO I COMBUSTIBLE MATERIALS _._DOW _ ... _. SIDES 0" . ... _..__ REAR 0" FRONT 3" TOP I FLUE -- 0" - --- -- -- HORIZONTAL (FLUE DISCHARGE ON THE LEFT) ALCOVE -- - - -- SIDES RIGHT 0 LEFT 0" FRO NT 18" TOP I" FLUE 0" CLOSET SIDES RIGHT I" LEFT i• FRONT S TOP I' FLUE 0" From Dwg.21C341286 Rev.3 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. License Information License PERFOHA I SORT Licensee Name PERFORMANCE HEATING & A/C INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600601386 Ind. Ins. Account Id 49459900 Business Type CORPORATION Address 1 7649 S 180TH Address 2 City KENT County KING State WA Zip 98032 Phone 4252510356 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 12/30/1985 Expiration Date 4/29/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date GOWIN, RICHARD L Expiration Date 01/01/1980 Impaired Date GOWIN, CONSTANCE F Received Date 01/01/1980 DEVELOPERS SURETY & INDEM CO Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #9 DEVELOPERS SURETY & INDEM CO 853803C 04/28/2002 Until Cancelled $12,000.00 04/23/2002 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: / /fortress.wa, gov /lni/bbip /printer. aspx ?License= PERFOHA 15ORT 11/16/2005