Loading...
HomeMy WebLinkAboutPermit M05-198 - FATIGUE TECHNOLOGYFATIGUE TECHNOLOGY City Tukwila Parcel No.: 0223400050 Address: 401 ANDOVER PK E TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tuklvila.wa.us Tenant: Name: FATIGUE TECHNOLOGY Address: 401 ANDOVER PK E, TUKWILA WA Owner: Name: GIBSON PROPERTIES L L C Address: 401 ANDOVER PARK E, TUKWILA WA Contact Person: Name: DOUG FROHARDT Address: PO BOX 2109, REDMOND WA Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109, REDMOND, WA Contractor License No: MERITMI163CM Value of Mechanical: $6,852.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 1 Ventilation Fan connected to single duct 2 Ventilation System 1 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC- Permit MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL OUTSIDE AIR FAN WITH DUCTING, VENTING FOR PROCESS OVEN, AND DUCTLESS SPLIT COOLING SYSTEM EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M05 -198 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 833 -9224 Phone: 425 883 -9224 Expiration Date:06 /01/2007 Steven M. Mullet, Mayor Steve Lancaster, Director M05 -198 01/31/2006 07/30/2006 Fees Collected: $235.00 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 01 -31 -2006 Permit Center Authorized Signature: V1, Signature: Print Name: doc: IMC- Permit City Gam Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila,wa.us M05 -198 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M05 -198 Issue Date: 01/31/2006 Permit Expires On: 07/30/2006 Date: Ol t l 0(1 I hereby certify that I have read an amin this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: / - 3 / — C 2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 01 -31 -2006 • City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223400050 Address: 401 ANDOVER PK E TUKW Suite No: Tenant: FATIGUE TECHNOLOGY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: M05 -198 ' Status: ISSUED Applied Date: 12/16/2005 Issue Date: 01/31/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M05 -198 Printed: 01 -31 -2006 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or regulating construction or the performance of work. Signature: 4 �Q Print Name: doc: Conditions as outlined. All provisions cancel the provision of any of law and ordinances other work or local laws Date: / - 3 / - M05 -198 Printed: 01 -31 -2006 2 CITY OF TUKWILA Community De•velopm en 2partment Public Works Department Permit Center 6300 Southcenter Blvd., Sub 100 Tukwila, WA 98188 • . Applications and.plans must be complete in order to be accepted for Plan review. Applications will not be accepted through the mail or by fax. • • • •**Please Print** - ". • • ,•• King Co Assessor's Tax No.: Site Address: . 1C) ( • Tenant Name e • 0 Property Owners Name Address: 'WO( tr •W4,111,.. 41014 0 Name: Mailing Address: Company Name: Majting Address: • Contact Person: E-Mail Address: E-Mail Address: • I • Suite Number: Floor: • City Day Teleph one: City Fax Number: ' .141 ?..,1,• IF • 1 . IT 44.04111.11 5 10 , A , ,,R,A-1090.21: . - • •'• Company Name: • Mailing ddress: - PC) City State Zip Contact Person: (P Day Telephone: L /75 - - 51:( — dress: . • . . Fax Number: C:r& - E-Mail Ad Contractor Registration Number: Expiration Date: • • = • . . **An original or notarized copy of current Washington State Contractor License must presented at the time of permit issuance** . • .. New Tenant: City Day.Telephone: Fax Number: • • Yes 95 • Stte " Zip " ' • i State , ' Zip. State . • . • • • • • Zip ajtv. sy 4 e Company Name: • Mailing Address: State Zip • Contact Person: • E-Mail Address: • permits plus \ice changes \ permit application (7 City Day Telephone: Fax Number: • -'..-:::,:-..":::.••;?-.i , . • • • . . .. . . ..,..... ' • ...;:?? ., •:: : , : - '4•?:••' . 1':si ' .., ';''' . ..f . i . :''.4 1 ildiftaif .. , :. .: • . , •..., . . -. ,. ,Existing '.'• • .-- ., ...... • - .. i ,„:.;,. - . to - riot ! , ;,...; . - .m 01':': ..:. tizi'.f: .. • • i '- i. .v. • ....• ......',Etiting.:. ... " ::: '.; '=:i:'.':- - : • • ' - • - : • s • : .. 14q* .•: . . '.....-. , - .. .qqiitftirciiO4 ,.: , '1): 6 4Bb ••••• ! I; ''fg!:..:. AS sfi'...'-.e:•.... ; ( gPY: • ' . • IBt'' oF..„;•':,, :: • ' ' ''' ...... ; Ai! yli t. ..- .....;!,-, - ... ..: . • • . . . . .. . • )ndEaiii : I .— :. •'; • .,: ...• • -- : . . 0,P.18:icifi....i•.:•..... !! :':. •-,',‘ . • -• ...• .t ; , ., .. ;.! • • .:' • • .. • • • •-,. 1 : , . ' •r; z; :: . : .•,, .! . .: . . : .. . .. - • . . . .. ,• • .•. '::!!; . • . • ,..,,..,-..,-,,....,.:,.,..,• • ,• . ... . ::.::. •;". :!' .. .........; •:;'*„.,..,,;• • .: .: ... 7 ...• ... • . -.• ',.; -.•„.;, ...',6.:.• . : ; '• ,': ''', " ! • -'" • , ' • • '' ' ' " " , :y!.`•.; ' '4' '-: • • Nti 71.,,...- . •eylr , ,',11•"•••i!..;:r•••••' • ;41:14.61114111t:il?:/-•-.•T .;: ..'.11%.5A! , , , ::. s... :, • 4 ••••:• ••• ' - •••:,..:, 7.... , .... .. • : • ' • :: ': •••!•'..!..'!......:::. -:.: i•,... :-. : `,‘• :' •' ‘ f::* ;,:, :',.--.,..! .';:•. ..:" ::-..... ;•••• : •-7- .-;" ',..":'••••':::':. ;':::%....!."':•! ' 7 . ,- .:,...: • s '..' :;,.:::'...; !! .y ..,,,.,. ..!. ;.! .,...•.-...... ".)'•,•-■;:;;.';:::•::',•.;'' ye, \', .! .... - • : 'P.::: ..!-•,,,,. ,..'• - t cso r y .;".•!.;,:".....,-. (•:, '...T.:' ; , .7.".'-'`..: :••• :'•:' •::• , • • ,;' • .'• -' • !!.; 1•:': . *, .. .... . .. . •!.."4: . *::!,7 - -..:. -.: ... - •.: • -...-i ...: -.... ::%:....::. • • - ; • • • • •A r ttidiod • Gaiiiq : . - • .:.•' .. • • • -, .-- - • ii..;.•,..7:,.........:t•': ;:■:' " ' ' . • • . • •- i cilt.oi;,.....:. ...:-.,:.;-.:-. •:•:.,.....?„..,,,,...; .,,, ..!. , -, :.>.'' - ! '. . . - * ' . :' '. r • ' " . - * '", f '.. '-':::' . • -:' ''' . ... . , . .!.6tt4t 00 4 '.. ,... , : ..., . . .•) ,.., . ... , , .. „ • . . • . li'C t4..... ';. ;:....',"' '7 i.,r : (,,,,;.., s,'• . ', - -..: 7 , •••• ' ,.. • . .;. , , • • .., '.,• . , • '-,:.,!..,..,;'., :•.,.. ..i: i,.t.,:tt.i.... '':: ' !•,.., 7..•: „ ,.z : '.- -.. 7 .11••••., • • , •Lli': .4.'...: - .,••• •: '' • '‘ •.:-)::-....... ' . ' • . t e, :: . ..'):', -.....* ,-, C •Pi • iteci:fdC '" ' ' !•. .- • ' : r •'• ' . '• ..• ' " • • ' - '. .'. • ' • .' .' ' .:...••• • . • •'. ' ' ' :- f" .: •••:, •• ". ,;•'.',* t ;' .:* ••• : . .• : '.. ' . .- ' Lliiet . .....:..,-... - ' • • .: ' ' • : • . • ,,• .• • *0••-•=411:71 VitrIZ11.4400 trata •var.t---,,,,ttrn.st: un•tt t-tt , ttt- ••-•• - tr-tr,t • • =-• t! • • tt, •• • r•-•.- • • • • Valuation of Project (contractor's bid Ped"* $ Existingallilding Valuation: $ • Scope ork (please provide detailed ihforniation)':.„- • • •• =.* • . PLANNING DIVISION: • • \Permit, plusVcc clanicsIpermit application (7-21:104) .:••,••.:2- • • Page 2 • •' " :•••••-• , . Will there be new rack storage? 0 ..Yes 1 • • If "yes" see Handout No • for requirements. ••••'•;.•• • • -•-. '•;•'•••'' •:- . •••'• '• • • . • focitiitint.(aida•otthe foundation ofall stiuctures, plus any decks over 18 inches and overhangs greater than 18 inches) . •• • • ••••• 4 Tor • an.Aceessofy.cliii.bllitig, provide the f011oWing:•• ••%, ' . • •• • • • • ••• • , • . • Lot:A . . . . • • Floor area 'of principal dwelling: ' 'floor area for acceSorY.dWelling: • ; doeUmentatiOn that shows that ohnir in'Ond of the'dWeilliiaiS" . . NUMber bf Parkiiik Stalls Provided: • • Standard: • • • • • • •-• :CoMpact:' . • llandiCapf • • ••-• • . -•:•-• Will there be a change in use? • 0 ....Yes • 0 „NO If "yes", explain: FIRE PROTECTION/IIAtARDOUS MATERIALS: 0.. Sprinklers 0 ..Automatic Fire Alarm • 0..None El. Other (specify) •:... ..... : . . . • Will there be storage or use of flammable, combustible or hazardous materials in the .building?' • • Ej:-,Ye .•••..:: .i:••,,, : ' . • .. ''. , 77 ''"• .;;: •.,..... • if "Yis",.attach list of materials and storage locations on 4 8-1/2 „i'll Papir.i,Wtitiiig4ilahtities. 4iictfidthrtai:SurAli Oath ;Slieeti.* . • :-',.' • ... . .. ... • , •. • • • . . . • .. . . . . .. . 1 1517.1:111P MIWASIMQ ;50 gROgellaagM 33- F- k i l ifiON■TEMIeWi t tn.65REAIfiggffslaikliaMINRINWRIMI Scope of Work (please provide detailed...linnet . , • Water District ...TukWila • 0 ...Water Availability Provided 0 ...Sanitary Side Sewer 0 ...Cap or'Renicive • . . o ...Frontage Improvententb o ...Traffi0 COritrol ' o ...BackfloW Prevention Call before you 1-800-424-5555 • glCase.iefet* tO:P11)4 4 fees • • • Proposed Activities (mark boxes that apply).: 0 ...Right-of-way Ube -.Nonprofit for less than.72 hours . 0...Right-Of-way Use - No Disturbance O ...Construction/Excavation/Fill - Right-of-way • ••.• :•":• ' • • ...Total Cut 0 ...Total Fill . . cubic.yards • . • . . Water iiistrici#I25'' ' • . . 0 :..kenton Sewer District • - . • • 0 ...TuicWila • .. .:-Renton . . ...Seattle . ... . . 0...Sewer Use Certificate • 0..,. Sewer Availability Provided 7 0 ..•::Approved Septic Plans ProVicieri: • .• • • 0 ..:Septic Systeiti - ror Onsite system, provide 2-copies of a current septic design approval by King County, Health Department .. ,.. ,- -. .,':;, .;•-•:•.:.. 2 ' . ' . ."' .: . • • . . • .. . . . . • Submitted with ApPlicaticiii(mk bOies WhiCli apprv): l t . '• • '.• • .''' •• El „civil Plans (MUxhutitoPape'r Size-22" X 34") . • 0 ..Technical information Report (Storm Drainage) 0 ...Bond 0.. Insuririce 0.. Easement(s) • • . • • • • . . • . • . .„ ...• • • ; • : • ' ibic yardS, - • ' 0 .-: Work in Flood 2eiie . 0 ..-:Stoim. Drainage 0 .. Abandon Septic Tank • o .. QeoteChnicalReport • 0 ...trailleIMPact Analysis 0.. MaintefiatAgfeernent(b) DHo1a Harmless • o .. Right-of-way Use:- Profit for less than 72 hoii • 0 Right-of-way Use — Potential Disturbance . . . . . Grease ithereeptor 0.. ch4h41000i! 1:1 .. Trench Excavation :. Utility.Undergiduriding ..'::: 0 ': ..... El .. Pavement Cut • • • -.• : • .. • 0 .. LOOpedFire.Lite . • : . . • - . ., . .. ire Protection . " • . . . . ., Irrigation . • • .". . . • • Domestic Water 0...Permanent Water Meter Size.... - If • • WO# . 0 .,:Temporary Water Meter Size :. • :1•...' " • WO#. - . ' • • .: . , . • . • .. ... .. 0......Water Only.Meter ' • .•':'.'''... .:•'•!.!!•..:. ;••74.4 111 '?f:'-': :::'•, : .... • .,.Dedliet Water Meter Siz ' • ':.* 0 ...Sewer Main Extension • ' Public :H ''.. • .'. Private . • - ..; . .., • .. . • • .: •• • • • ..• :. . ' . ... ....• 0 .:.Water,Main Extension - Public : • . Private:. • . ' • •■ •. • • • . . ` . .• • ` • • . • • •• • • • . •.• • • • .s • •••'' • : `.- • • . • • • . FINANCE INFORMATION • , Fire Line Size at Property Line. • • .Nuniber of Public Fire Hydrant(s) 0 ...Water Monthly Service Billing to: Name: . . Mailing Address: Se'wer SA Treattherit • • City ' Water Meter Refund/Billing: Day Telephone. Name: . Mailing Addresb: Day Telephone: City State • State:: . Zip ;,. Zip , s-,.. • • • • • ' • • .• * • • • • i• kpennits pluoc changes1Permit application (7-2004) ..?•:• • : 7 •, • . . .Untt.Typ'e: ... ; Q �'. UnieT a :.. '..... YP ..',, •Qty:. ;U <.Qty•' B'atler om, ''pr`e §'s ".:. . Qh' Furnace <100K BTU Air Handling Unit >10,000 CFM , Fire Damper 0 -3 HP/rOTOMT3TU f.: Furnaee>100K BTU Evaporator Cooler 'Diffuser 3 -15 11P /500,000 BTU . Floor Furnace Ventilation Fan Connected to Single Duct ' Thermostat 15 -30 HP /1,000,000 BTU . Suspended/Wall/Floor Mounted Heater Ventilation System • • - Wood/Gas Stove . . 30 -50 HP /1,750,000 BTU • • Appliance Vent Hood and Duct ' ' Water Heater 50 +HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic • Emergency Generator . . . Air Handling Unit <10,000.CFM • Incinerator— Comm/Ind .. Other Mechanical Equipment ' . kt�i ?t•y /f 1 " 4 .. _... 1.1� . i , 'h.1.•M ::LH-AA9' M'e.: i7:��: d5, _li:v r.wfyrTi. r f 11 tad "v�:� .. ZVIE X411 C' �� R1l�I C ATICjN'_ ' d= • 4. 1 . 1 �i�: r of a, } • .�,,., � {°� -1' V A.; r1 � � [ €s��y } 5� r•lt" ` °� �{ r ia?rL S'._ r igt :e• _t — +.�� S,.fA: . isK.' S; �kk rrt�a _tr:�}-+' -"l ati��, i, 9,- �^,_ ,- �.,,['•� #- .i.T.•.�fr..F� -=.,t �•� - +..: .�, MECHANICAL CONTRACTOR INFORMATION Company Name: f - A Est; -73 Mailing Address: QG M-% 2 - 16 '1 • City; State Zip Contact Person: Z>Ge.s • - • • • Day Telephone: YZS - S - 3 - 9•Z E -Mail Address: 0L-1 ,t.te; -� "� rv�ec�c. -.L t ;• Fax Number: (1 zs') r4 ' - C3• (a Contractor Registration Number: /14 117.a- i M:1- / 1 ev3 'C Expiratiori Date: . Gam � .C) '7 ' • * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** sr5Z ` 0 (;&e_ Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): V• • Use: Residential: : . New .:. ❑ Replacement ❑ ; Commercial: New .....g Replacement . ❑ Fuel Type: Electric ❑ Gas....❑ Other::::. • ... Indicate type of mechanical work being installed and the quantity below: BUILDING OWNER OR AUTHORIZED AGENT: • Signature 2.� 445 E p� Print Natne: c }jrC. - S-c-Ke \ A\ 01 Mailing Address: 120 Ro}o o2 /0 Date Application Accepted: permits plus'Jcc changes \permit application (7 -2004) Page 4 .. City • .. • k Date: `T�JIQES =� ..' bti Je A erAnitsAn thIsFag z L Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. • • • • • • • Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall .expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180'days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be,extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER . PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Telephone: 7 - - k7,2: - 4 / . 5 . . ,State Zip ' Date Expires: (le tA9 Staff Initials: ..,: ;\t)r ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223400050 Address: 401 ANDOVER PK E TUKW Suite No: Applicant: FATIGUE TECHNOLOGY Payee: MERIT MECHANICAL, INC. Payment Check 80400 MECHANICAL - NONRES RECEIPT Receipt No.: R06 -00132 Payment Amount: 194.00 Initials: 7EM Payment Date: User ID: 1165 Balance: TRANSACTION LIST: Type Method Description Amount Account Code Current Pmts 000/322.100 194.00 Permit Number: M05 -198 Status: APPROVED Applied Date: 12/16/2005 Issue Date: 194.00 Total: 194.00 01/31/2006 10:49 AM $0.00 1842 01/31 9719 TOTAL 194.00 Printed: 01 -31 -2006 it Is Is U O '; co D U) W W O g :3 J ` CO 3 Z �; . W uj D o' V co ±0 I— LL) uj VE u- O Z , U N Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0223400050 401 ANDOVER PK E TUKW FATIGUE TECHNOLOGY R05 -01806 3EM 1165 MERIT MECHANICAL, INC. TRANSACTION LIST: Type Method Payment Check 22120 PLAN CHECK - NONRES Description Account Code 000/345.830 RECEIPT Permit Number: Status: Applied Date: Issue Date: Amount 41.00 Current Pmts 41.00 Total: 41.00 M05 -198 PENDING 12/16/2005 Payment Amount: 41.00 Payment Date: 12/16/2005 02:01 PM Balance: $194.00 0314 12/16 9710 TOTAL 41.00 Printed: 12 -16 -2005 W: UO NO' cn w ., W O: a: • ' W Z tu 13 I— F-; W U Z; O 2 , ProJec . Type of Inspe on: Add re o /. ^r / : Date Called: Special Instructions Date Wanted: / � p'mc Requester: Phone No: N NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: /,‘ $58.00 REINSPECTION'FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: IDate: Project: // 7 _, i _ Type of Inspection: ,- - I_ .rs. •i /i Address: In struc t Date ailed: Special ns:v Date Wanted: -/ ��t a.m. C' Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECT' NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 , !' ! Inspector: Datel / -i 2 Approved per applicable codes. El Corrections required prior to approval. $58.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: Date: Pro . / Le.-- /r./.4 — �tr�7Gr .�i Type of Inspection* 7 � or / —1?j Adds: \, J 4 47 Date Called: Special Instructions: "-- Date Wanted: ! ,. a.rri, Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. kros-/7,5 a.. PE (206)431 -3670 ■T, COMMENTS: l�.�v .' 07,.6 1 -2, k (Inspector: G4K Dater / / - Corrections required prior to approval. $58.EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. W' i t 2. - V 0 0 - u) CO W =, LL: W O, • I Via. O n . U D O w • :0 1--• .Wa U . . U co:. , Protect i . ,_ __ G Type of Inspection: ' Address: L 0 (.. �r Date Called: Special Instructions: ' I Ci Get /47 ��-1 (-- 4 yon Date Wanted: Z .-7"7„..06, p.m. Requester: A i / � y , , ! Y tr ee ! it rd' /Stuh Phone No: L f 7�S •—• y4( S'-f17:‘ -7 0 Approved per applicable codes. NTS: Receipt No.: ... INSPECTION RECORD Retain a copy with permit INSPEU'ION NO. - CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Date: (206)43 1 -36 Co Corrections required prior to approval. ri $58.OEINSPECTIO REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Doug Frohardt From: Wade Morris [wmorris ©FatigueTech.com] P , Sent: Tuesday, January 10, 2006 3:13 PM To: Doug Frohardt Cc: Kevin Dooley; Chuck Copple; Bruce Bart; Dale Young; Russell Toft; Mark Weiss; Wade Morris Subject: Powder Coating Information (Bluecoat) Attachments: DMLIB- #194719- v1- Vantage_FCMPowder BoothBrochure.PDF; DM_LIB- #194729 -v1- VAN_TAGE_FCM Filter Information__48- inch.DOC; DM _ LIB - #194712 -v1- RECEIVED Bellcoat 1001_MSDS_Sheet.PDF; DM_LIB- #194519 -v1- CITY OF TUKWILA Fluidized Powder _Coating_Process_Outline.DOC; DM_LIB- #194730 -v1- Wisconsin Oven_SBH- 23_Data_Sheet.PDF JAN 1 3 2006 Doug, Please find the attached files that include MSDS sheets for the Bluecoat powder, brochures for the powder filters, booth and powder curing oven. Included is information relating to the equipment power requirements, powder flammability, dust contamination, operator safety and filter capture particulate size. In addition to these documents, applicable government documents relating to powder coating include International Fire Code, Section 1507 "Powder Coating ", and WAC 296 -24- 37023 "Powder Coating ". The combination of all this information should be sufficient to satisfy any curiosities of the Tukwila City Officials. If it does not compel them to approve our application, please contact me immediately with any requests for additional clarification. Notice that I refer to this unit as a "powder booth ". It is NOT a paint booth. It is specifically designed and suited to capture airborne dust for powder coating operations. Unfortunately, it seems that the use of the word "paint booth" in discussion and on the facility drawings has caused city officials significant misunderstanding and attention to be drawn to this application. Please take every precaution in the future to refer to this system as a "powder booth" and NOT a "paint booth ". This powder is applied in a dry state. Also, be aware that the powder booth brochure uses the word "spray ". Although many manufacturers prefer to spray the dry powder, we will not be applying the powder coating with a spray method. Our method is to dip the heated parts into a "powder fluidizing bed ". This minimizes the amount of airborne dust thereby reducing any health and safety concerns. Unlike painting methods, there are no solvents used in powder coating applications. I have also included a document with a brief explanation of the process and equipment to be used that I provided to the Tukwila Fire Department and may also be attached to your application to the city. Proprietary Information This document contains information of a proprietary nature. Therefore, the receiver of this documen must treat it accordingly and not transmit, reveal, or disclose it or any part thereof to any oth = _ • ' r : itRexpre written consent of Fatigue Technology Inc. (FTI). R tU CODE PLIANCE QQOQA JAN 2. 6 2006 Wade M. Morris, P.E. Project Engineer Phone: 206.246.2010 x284 Fax: 206.244.9886 www.fatiguetech.com FTI: World leaders in fastener, bushing and fatigue life solutions. "Celebrating 35 Years in the Aerospace Industry" PerMIt City Of Tukwila BUIL nnl ��N( n Page 1 of 1 PERMIT CENTER CORRECTION LTR/ r L re w 6 U vi to 9 to O 2 g J; u - N 0 v-- W. z H O ' Z uj D I- w uj V Z Value. Flexibility. Performance. z � 00 coo J H WO < I d W Z 1- O Z !- W W O- 0- W W S H -O .. Z W U = OF- Z ' Vantagem FCM Powder Spray Booth Even the largest walk -in booths for coating large agricultural components require no more than two Vantage modules compared to several conventional modules. Quiet, cost - effective, flexible powder spray booths for manual powder coating operations and selected automatic operations. The Nordson Vantage FCM (fixed collector module) family of powder spray booths combines production - proven performance and reliability with innovative design. The result is a very cost - effective coating solution. Vantage FCM is ideal for job shops, first -time powder coating operations and companies who want to economically expand their powder coating production. Fewer modules save money on the initial investment and in ongoing operating costs. • • Lower Costs with a Range of CFM Capacities The Vantage powder spray system is available in a wide range of single module configurations from 5300 CFM to 11000 CFM capacity. Vantage achieves high CFM capacity in single, larger modules as opposed to the conventional use of multiple lower CFM modules. Fewer modules save money on the initial investment and in ongoing operating costs. Flexible Design for More Applications Vantage is designed for coating large products in larger walk -in batch or conveyorized operations, but is equally suited for smaller operations with a single, smaller CFM module. Vantage's flexible design accommodates a variety of applications. 4 Batch operations - final filters are oriented to exhaust forward and upward, allowing a booth to be positioned directly up to a wall for the best use of space. -� Conveyorized operations - final filters are oriented rearward and upward, away from the conveyor slot. 4 Common control panel - for running booth and application equipment. Superior Design and Components Nordson uses high - quality manufacturing and performs extensive factory testing for optimum performance and reliability, and exceptionally quiet operation. Because there is no compromise on any design details, coaters receive maximum powder containment and reliability with reduced noise levels. Ultra- Compact, Ultra- High -Flow Model The Vantage Lean Cell' model accommodates large parts while minimizing floor space and conveyor line gaps, for both manual and automatic powder applications, and exceptionally fast color change. Lean Cell'' booth minimizes floor space and conveyor line gaps in manual and automatic applications. fie Flexible design accommodates various booth canopies. VantageTM FCM Specifications and Utility Requirements Number of Primary Filters 4 4 6 8 Number of Final Fitters 2 2 4 6 Features and Benefits of Vantage FCM Spray Booths Vantage provides maximum value, flexibility and performance in a powder spray booth for manual powder coating operations and selected automatic operations. 4 Wide range of CFM capacities - 5300, 6400, 7200, 9600, 11000 to meet your specific application requirements. 4 Larger CFM capacity single filter/collector modules reduce the initial investment and operating costs. 4 Superior design and components for exceptionally quiet operation compared to conventional designs. 9 Flexible design - to accommodate batch or conveyorized operations. 4 High - quality manufacturing and factory tested for optimum performance and reliability. 4 48 - inch polyester filters for superior filtration performance, longer filter lite and minimum powder retention. ▪ Full - function, UL 508 - compliant control panel with safety Interlock comes standard on all models. - 7lmed reverse pulsing of filters for optimum performance and filter life. 9 Optional fluidized or non - fluidized powder collection trays for cleaner operation and powder reclaim capability. 4 Module shipped In sections for fast, easy on -site installation. 4 4 4 SPECIFICATIONS Model 5300 Model 6400 Model 7200 Model 9600 Model 11000 Module Dimensions (Wx H x D) 6'x10' 6' x 10' 9' x 3' 6' 9' x 10' 9' x 3' 6' 12' x 10' 10' x 3' 6' 12'x11'x3'6' Rated CFM 5300 6400 7200 9600 11000 8 6 Air input Size 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT Air Consumption @100 PSI 15 SCFM 15 SCFM 20 SCFM 25 SCFM 27 SCFM Motor HP 5 7.5 7.5 10 15 RPM 1750 1750 1750 1750 1750 VoltsiHz/Amps Motor 208/60/17 208/60/24.5 208/60/24.5 208/60/32 208/60/48 230/60/15 230/60/22 230/60/22 230/60/27 230/60/42 380/60/12 380/60/16 380/60/16 380/60/18 380/60/28 460/60/7.5 460/60/11 460/60/11 460/60/14 460/60/21 575/60/7 575/60/9 575 /60/9 575 /60/11 575/60/17 Controls — — 110/60/10 110/60/10 110/60/10 110/60/10 110/60/10 From powder booths for smaller, short -run, non - reclaim operations to larger, long-run continuous operations with manual powder recovery, the flexible design of Vantage allows fora broad range of applications. Optional fluidized or non - fluidized powder collection trays for cleaner operation and powder reclaim capability. n u'rrsuaJson.cv o 2t)4 uorwton C,PoraWn aPoga Re6eted For more information on Vantages" equipment, talk with your Nordson representative or visit our website at Vantage RCM (Removable Collector Module) Booth Designed for manual and automatic conveyorized applications with color change and powder reclaim capability. United States Amherst, Ohio Telephone: 800.626.8303 Facsimile: 888.229.4580 Web: www.nordson.com /powder E-mail: powder @nordson.com Canada Markham, Ontario Telephone: 800.463.3200 905.475.6730 Facsimile: 905.4 75.8821 :('u Europe Erkrath, Germany Telephone: 0049.211.9205.141 Facsimile: 0049.211.9252.148 E•ma l; powdecsystems@de.nordson.ccm Nordson u'u'u nordson.co jp Nordson Corporation • 300 Nordson Drive • Amherst, Ohio 44001 The Nordson value -line of Vantage systems and equipment is designed and engineered to meet reclaim or non- reclaim, fast;color . change powder coating requirements:. Vantage Automatic Gun Control System Engineered for simple, yet highly effective control of automatic powder spray applications for maximum transfer efficiency and finish quality. Nordson reserver the right to make design changer to products to improve :heir function. These changes may occur beturen printings. For more information, talk with your Nordson representative or contact your Nordson regional headquarters office. Japan Tokyo, Japan Telephone: 81.3.5762.2700 Facsimile: 81.3.5762.2701 E -mail: ppa.dm @nordson.co.jp Asia/Australia/Latin America Amherst, Ohio Telephone: 440.985.4000 24 -hour message service: 440.985.47 97 E -mail: intcustomerservice @nordson.com PKL•w•3152 rs9, d 10/04 NORDSON FILTER EFFICIENCY INFORMATION VANTAGE FCM Modules and Booths The two -stage filtration of the Nordson Vantage FCM Powder Coating Systems has been specifically designed to ensure that the air returned to the plant from the powder- coating booth is as clean as possible. The primary filters knock down a majority of the over - sprayed powder for easy collection and reuse. The secondary filters eliminate any particles that get through the primary filters before the booth air is exhausted back to the plant. PRIMARY FILTERS: The first stage of filtration in the Nordson Vantage FCM Powder Coating Booths is a set of single - stacked, 48" -inch long cartridges filters made of 100% spun- bonded polyester (Nordson, Part No's. 1042591). Since there is not a "standardized" test for determining the efficiency of cartridge filters subject to pulse cleaning, a procedure similar to The American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) paper RP531 was followed to determine the efficiency by weight of the cartridge filter. These tests were conducted with 48 -inch filters at 1200 cfm using Valspar Flat Black Epoxy 1000B3 Powder Paint with a particle size distribution and specific gravity typical of most powder paints. Efficiency should improve using a 48 -inch long filters at either 1200 or 1600 cfm. Most of the powder that gets through these cartridge filters is under 1 to 5 microns in size. ** The Efficiency by Weight value listed can be used to determine the amount of powder by weight, which will be captured by the cartridge filters during normal operation. For example, the efficiency by weight of the Heavy -Duty filter is 99.999841 %, meaning that for every 100 pounds of powder fed to the cartridge, it should capture 99.999841 pounds and allow 0.000159 pounds to go to the secondary filters. SECONDARY FILTERS: The second stage of filtration is a set of panel filters made from glass micro fiber media (Nordson Part No 1042596). These filters are rated as 90 -95% ASHRAE filters. This means that the media used in the filters has been tested using ASHRAE Standard 52 -76 test procedures. The ASHRAE Standard 52 -76 test is a standardized test common in the filtration industry, which measures the filtration efficiency of the filter media using a standard test dust at a specific airflow. Testing has shown these panel filters to be 100% efficient with particle sized over 5.0 microns. By weight, these filters will capture 99.99% of the powder fed to them. This was determined using ASHRAE Standard 52 -76 test procedure using ASHRAE Standard Test Dust. We use these filters primarily to capture the particles under 1 to 5 microns that are not captured by the primary filters. Percept Removal Efficiency by Particle Size: Nordson Part No 1042596: Filter Material: 90 -95 ASHRAE glass micro fiber media 0.3 microns 60% Rated Airflow: 1200 -1700 cfm, varies depending on part number 0.7 microns 94% Test Procedure Used: ASHRAE 52 -76 1.0 microns 98% Test Dust Used: ASHRAE Standard Test Dust 3.0 microns 99.99% Average Synthetic Dust Spot Efficiency: 90.2% 5.0 microns 100% Average Synthetic Dust Weight Arrestance: 99.99% Initial Pressure Drop: 1.0 inches w.c. Revision Date: 27, January 2004 Nordson Polyester"! Nordson Part No's 1042591 Nominal Length 48 -inch Diameter 12.75 inch Filter Media Material 100% spun- bonded polyester Design Airflow 1200 to 1600 cfm per cartridge Efficiency by Weight ** 99.999979% NORDSON FILTER EFFICIENCY INFORMATION VANTAGE FCM Modules and Booths The two -stage filtration of the Nordson Vantage FCM Powder Coating Systems has been specifically designed to ensure that the air returned to the plant from the powder- coating booth is as clean as possible. The primary filters knock down a majority of the over - sprayed powder for easy collection and reuse. The secondary filters eliminate any particles that get through the primary filters before the booth air is exhausted back to the plant. PRIMARY FILTERS: The first stage of filtration in the Nordson Vantage FCM Powder Coating Booths is a set of single - stacked, 48" -inch long cartridges filters made of 100% spun- bonded polyester (Nordson, Part No's. 1042591). Since there is not a "standardized" test for determining the efficiency of cartridge filters subject to pulse cleaning, a procedure similar to The American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) paper RP531 was followed to determine the efficiency by weight of the cartridge filter. These tests were conducted with 48 -inch filters at 1200 cfm using Valspar Flat Black Epoxy 1000B3 Powder Paint with a particle size distribution and specific gravity typical of most powder paints. Efficiency should improve using a 48 -inch long filters at either 1200 or 1600 cfm. Most of the powder that gets through these cartridge filters is under 1 to 5 microns in size. ** The Efficiency by Weight value listed can be used to determine the amount of powder by weight, which will be captured by the cartridge filters during normal operation. For example, the efficiency by weight of the Heavy -Duty filter is 99.999841 %, meaning that for every 100 pounds of powder fed to the cartridge, it should capture 99.999841 pounds and allow 0.000159 pounds to go to the secondary filters. SECONDARY FILTERS: The second stage of filtration is a set of panel filters made from glass micro fiber media (Nordson Part No 1042596). These filters are rated as 90 -95% ASHRAE filters. This means that the media used in the filters has been tested using ASHRAE Standard 52 -76 test procedures. The ASHRAE Standard 52 -76 test is a standardized test common in the filtration industry, which measures the filtration efficiency of the filter media using a standard test dust at a specific airflow. Testing has shown these panel filters to be 100% efficient with particle sized over 5.0 microns. By weight, these filters will capture 99.99% of the powder fed to them. This was determined using ASHRAE Standard 52 -76 test procedure using ASHRAE Standard Test Dust. We use these filters primarily to capture the particles under 1 to 5 microns that are not captured by the primary filters. Percept Removal Efficiency by Particle Size: Nordson Part No 1042596: Filter Material: 90 -95 ASHRAE glass micro fiber media 0.3 microns 60% Rated Airflow: 1200 -1700 cfm, varies depending on part number 0.7 microns 94% Test Procedure Used: ASHRAE 52 -76 1.0 microns 98% Test Dust Used: ASHRAE Standard Test Dust 3.0 microns 99.99% Average Synthetic Dust Spot Efficiency: 90.2% 5.0 microns 100% Average Synthetic Dust Weight Arrestance: 99.99% Initial Pressure Drop: 1.0 inches w.c. Revision Date: 27, January 2004 Ingredient Percent TLV PPM mg /M s LEL Vapor Pressure mm Hg. 20 DEC c N/A N/A N/A N/A N/A N/A Material Safety Data Sheet For Coatings, Resins and Related Materials Boiling Range N / A Similar to Form OSHA -20 Attention: Safety Director The information contained herein is based on data available to us and is believed to be correct. Since this information may have been obtained in part from independent laboratories or other sources not under our direct supervision, no representation is made that the information is accurate, reliable, complete or representative and Buyer may rely thereon only at Buyer's risk. We make no guarantee that the health and safety precautions we have suggested will be adequate for all Individuals and/or situations involving its handling and use. No warranty is expressed or implied regarding the accuracy of these data or the results to be obtained from the use thereof. Vendor assumes no responsibility for injury to vendee or third person proximately caused by the material if reasonable safety procedures are not adhered to as stipulated in the data sheet. Product Class EPDXYS Trade Name None CAS # N/A N / A = Not Applicable Section III - Physical Data POWDER TECHNOLOGY INC P.O. Box 108, Schofield, WI 54476 Manufacturers of Quality Powder Coatings FAX: 715-359-4126 715 - 359 -4999 Section 1 Manufacturer's Code ID: PT- ES90 -LF33 BELLCOAT 1001 Section II - Hazardous Ingredients SARA 313 40CFR 372 Chemical Name N/A Section IV - Fire and Explosion Hazard Data 1 POWDER TECHNOLOGY. INC. Percent By Weight N/A Page 1 af 2 Vapor Density 7j Heavier 1 Lighter, Than Air N / A Evaporation Rate IlFaster i.lower Than Ether N / A % Volatile By Weight < 1.0% Weight Per Gallon N / A DOT Category Not a Regulated Substance Flash Point N / A Extinguishing Media Use Dry Chemical, Foam, Carbon Dioxide or Water Fog. Unusual Fire and Explosion Hazards At certain concentrations powder dust can form explosive clouds. Special Fire Fighting Procedures Do not make dust clouds. Do not use high pressure water. Wear NIOSH /MSHA - approved self- contained breathing apparatus. Material Safety Data Sheet For Coatings, Resins and Related Materials Similar to Form OSHA -20 Attention: Safety Director Respiratory Protection Ventilation Protective Gloves Eye Protection Other Protective Equipment Other Precautions Date Prepared: 8/1/2002 POWDER TECHNOLOGY INC. Section V - Health Hazard Data Threshold Limit Value Not Established 10 mg /M 3 as a nuisance dust. Effects of Overexposure Repeated breathing of dust may cause lung congestion. Emergency and First Aid Procedures Eyes: Flush with large amounts of water. If irritation persists seek medical attention. Skin Contact: Wash with soap and water. Ingestion: If a large amount is ingested give water; induce vomiting, seek medical attention. Inhalation: Remove to fresh air and provide oxygen if breathing is difficult. Get medical attention. Section VI - Reactivity Data Evaporation Rate ;Unstable AStable Condition to Avoid Exposure to spark and flame. Incompatibility (Materials to avoid) Hazardous Decompostion Products Carbon Monoxide, Carbon Dioxide, Hydrocarbons when thermally decomposed. Hazardous Polymerization 11May Occur : Will not Occur Condition to Avoid Section VII - Spill or Leak Procedures Steps to be taken in case material is released or spilled Using approved Dust Respirator, scoop or vacuum up with spark free vacuum and discharge with solid waste Waste Disposal Method Bury in local landfill in accordance with federal, state and local regulations. We make no guarantee or warranty of any kind that the use or disposal of this product is in compliance with all federal, state or local laws. It is the obligation of each user of the product mentioned herein to determine and comply with the requirements of all applicable statutes. Section VIII - Special Protection Information If ventilation is insufficient use a NIOSH - approved Particulate Respirator. Explosion proof ventilation equipment sufficient to operate below the lower explosion limit. Wear gloves to minimize contact. Wear goggles to keep airborne particles out of eyes. Wear clean clothing daily to minimize skin contact. Section IX - Special Precautions P.O. Box 108, Schofield, WI 54476 Manufacturers of Quality Powder Coatings FAX: 715-359-4126 715 - 359 -4999 POWDER TECHNOLOGY, INC. Page 2 of 2 Precautions to be taken in handling and storing Ground all processing equipment. Eliminate ignition sources. Use explosion proof electrical equipment. Use good housekeeping measures to eliminate accumulation of dust. Wash with soapy water before drinking, eating, smoking. ,................ . ,mot ... t. F FATIGUE TECHNOLOGY INC. Powder Coating Media: TEL: (206) 246 -2010 FAX: (206) 244 -9886 FTI Application Method for Powder Coating Bushings January 6, 2006 Wade M. Morris 401 Andover Park East Seattle, Washington 98188 -7605 USA This document is generated for use by the Tukwila Fire Department for evaluating FTI's equipment and method for powder coating application of Bellcoat Powdered Epoxy Resin. Equipment used: • Powder Coating Booth (UL 508) • Nordson, Model: Vantage FCM Batch Powder Booth • Industrial Batch Oven (UL 508) operating at 500 Deg. F Maximum • Wisconsin Oven Corporation, Model: SBH -223 • Powder Fluidizing Hopper (50 Pound Capacity, Non - Electric) • Air conditioning and ventilation system (Professionally installed by Merit Mechanical) Common Name: Bellcoat Manufacturer: Bell Helicopter Textron Manufacturer Part Number: Material Specification 299 - 947 -395 H of dipping in fluidized powder • Parts to be coated are heated in the oven to 350 — 500 Deg. F. • Parts are removed from the oven and submerged in fluidized powder (Bellcoat) until an adequate coating thickness is achieved. • After coating, the parts are returned to the oven for 2 -5 minutes to cure and harden the coating. This process and all equipment used in association with the process shall meet the requirements established in the International Fire Code; Section 1507 "Powder Coating ", as well as all local and state regulations. Proprietary Information This document contains information of a proprietary nature. Therefore, the receiver of this document must treat it accordingly and not transmit, reveal, or disclose it or any part thereof to any other organization without the express written consent of Fatigue Technology Inc. (FTI). www.fatiguetech.com • world leaders in cold expansion technology • extending the fati e life of metal structures and materials BECKMAN File name: File ID: Sample ID: Run number: Optical model: Fluid R.I.: Residual: LS 13 320 SW Start time: Average Vacuum: Obscuration: Software: a) E 0 Volume: Mean: Median: D(3,2): Mode: dio: dso: d9o: ov < Nm 10 15.07 LS Particle Size Analyzer POWDER TECHNOLOGY ,INC C : \LS13320\KG- FILES \KG003 BELLCOAT_153.$Is KG003 BELLCOAT MIX 1 TRIAL 1 153 Gamet.rff 1 0.61% Dry Powder System 9:48 25 Jul 2005 12.9" H2O 10% 4.03 Volume Statistics (Arithmetic) Calculations from 0.375 pm to 2000 pm 100% 58.46 pm 48.89 pm 26.83 pm 55.13 pm 15.07 pm 48.89 pm 118.2 pm 25 28.30 Plan r - Sample R.I.: t .: 1.8 10.3 c. Run length: 34 seconds Firmware: L,. 2.02 0 Differential Volume S.D.. C.V.. Skewness: 1 Kurtosis: 1 Page 1 19 Jan 2006 13:32 KG003 BELLCOAT_153.$Is 41.28 pm 70.6% .210 Right skewed .357 Leptokurtic 50 75 90 48.89 77.44 118.2 FILE COPY Permit No. --REVIEWED FOR---- CODE COMPLIANCE forsnommn JAN 2 6 2006... b Tuk'NI • BUILDING f1T` STON I 1 I I I I I 2 4 6 10 20 40 100 200 400 1000 Particle Diameter (pm) FleOWIVED CITY OF TUKWILA JAN 2 G 2006 ^7.'1sslons. :;rize :Ipt (.. :J: ;t. r ._.._.1r Nordson Part Numbers Y . f ','. g Y i � y ..:..ge {.:x� lY F,,, F �- rI ' 5 , nV .c ..1 .`i..A 1 `;.f`.,r..., �.>.„... ..sn . 180773 and 180774 ycr' ? ?rti ±r ,,,., e :. .. „ fi t 1 �. � y 1 f " •� j NM .,� t '-,, �' "; .' .,. .Fa4 n,.�.. s,...? .t_t, , i.iA,` .iP. 146416 and 146418 ;^ r •. ; ,.:: . ;y + ,�. ;t s.YtF..t .4 147162 and 147163 Nominal Length 26 inches 26 inches 26 inches Diameter 12.75 inches 12.75 inches 12.75 inches Filter Media Material cellulose and polyester blend 100% spun- bonded polyester cellulose and polyester blend Design Airflow 500 cfm per cartridge 500 cfm per cartridge 500 cfm per cartridge Efficiency by Weight" 99.999841% 99.999979% 99.999699% "The Efficiency by Weight value listed can be used to determine the amount of powder by weight which will be captured by the cartridge filters during normal operation. For example, the efficiency by weight of the Heavy -Duty filter Is 99.999841%, meaning that for every 100 pounds of powder fed to the cartridge, it should capture 99.999841 pounds and allow 0.000159 pounds to go to the secondary filters. Crdso� Nordson Filter Efficiency Information 808, 904, NHC -4, NHC -8, ReadyCoat, Econo -Coat (NVC -4), and Versa -Coat (Batch Booth) Powder Coating Systems The two -stage filtration of Nordson powder coating systems has been specifically designed to ensure that the air returned to the plant from the powder coating booth is as clean as possible. Primary Filters The first stage of filtration in Nordson powder coating booths is a set of double- stacked, 26 -inch long cartridge filters (Nordson Heavy -Duty, parts 180773 and 180774) made of a heavy -duty blend of cellulose and polyester. Two alternative types of 26 -inch long cartridge filters may also be used in some systems: • Nordson PowderGrid, parts 146416 and 146418, is made 100% spun - bonded polyester. • Nordson High - Efficiency, parts 147162 and 147163, is made of a high - efficiency blend of cellulose and polyester. NOTE: The High- Efficiency cartridges are standard in the Econo -Coat (NHC -4) and Versa -Coat booths. 2005 Nordson Corporation • The primary filters knock down a majority of the over - sprayed powder for easy collection and reuse. • The secondary filters eliminate any particles that get through the primary filters before the booth air is exhausted back to the plant. Since there is not a standardized test for determining the efficiency of cartridge filters subject to pulse cleaning, a procedure similar to the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) paper RP531 was followed to determine the efficiency by weight of all three types of cartridge filter. These tests were conducted with 26 -inch filters at 500 cfm using Valspar Flat Black Epoxy 1000B3 Powder Paint with a particle size distribution and specific gravity typical of most powder paints. Most of the powder that gets through the cartridge filters is 1 -5 microns or less. ., , t`ir�'Fl: %: •.�'ay' rrC,Y. Nordson Part Numbers ° • V+ 1, .It y4'wi', i:x3 i;'fT . 71 ; .fn ��H, ?Lc 7,,I . :�yn rir , ,,-- .� SC};,;�},,i :: _ �.v ,. t- ..k -.. ,.,3.c .:__...k ::fa•�bL:.av .�c< r .. ...i N +? i < ,z� , ..7 II del �n dl '* ��3.. -�a 101429, 101430, 101432 Filter Material 90 -95% ASHRAE glass micro -fiber media Rated Airflow 1200 -1700 cfm per filter (depending on part number) Teat Procedure Used ASHRAE 52 -76 Test Dust Used ASHRAE Standard Test Dust Average Synthetic Dust Spot Efficiency 90.2% Average Synthetic Dust Weight Arrestance 99.99% Initial Pressure Drop 1.0 inch w.c. 2 Nordson Filter Efficiency Information Secondary Filters The second stage of filtration in Nordson powder coating booths is a set of panel -type filters (Nordson parts 101429, 101430, and 101432) made from glass micro -fiber media. These filters are rated as 90 -95% ASHRAE filters, This means that the media used in the filters has been tested using ASHRAE Standard 52 -76 test procedures. The ASHRAE Standard 52 -76 test is a standardized test common in the filtration industry, which measures the filtration efficiency of the lifter media using a standard test dust at a specific airflow. Testing has shown these panel filters to be 100% efficient with particle sizes over 5.0 microns. By weight, these filters will capture 99.99% of the powder fed to them. This was determined using ASHRAE Standard 52 -76 test procedure using ASHRAE Standard Test Dust. These filters capture the particles 1 -5 microns or Tess that are not captured by the primary filters. Issued 2/05 Original copyright date 1995. Econo -Coat, Nordson, the Nordson logo, PowderGrid, and Versa -Coat are registered trademarks of Nordson Corporation. Ready Coat is a trademark of Nordson Corporation. CITY OF T IKKWILA J M 4 2 6 'LOOG PERMIT CENTER CI 2005 Nordson Corporation Econo -Coat Series Powder Booth /Collector Systems Interchangeable component design for maximum operating flexibility Nordson's compact Econo -Coat powder spray booths are designed to meet a wide range of manual coating requirements for increased production flexibility. The expandable design includes a variety of powder collection modules to minimize the number required for conveyorized booths or larger, walk -in -batch booths. This reduces overall floor space and lowers capital investment and maintenance costs. The configurable modules are easily upgraded with optional components to increase airflow capacity to meet changing production requirements. The Econo -Coat Series of powder spray booths offer the same reliability and durability of Nordson's engineered, fully automated systems. They are ideally suited for manual batch production and laboratory applications, short -run batch and conveyorized custom -color coating operations, as well as a companion to large engineered systems. Wide Range of Collectors Available An expanded range of airflow capacities is featured with Nordson's Econo -Coat collector modules. This may minimize the number of modules required for conveyorized booths or larger, walk -in batch booths. The need for fewer modules minimizes floor space and provides more flexibility in designing a system that delivers reliable performance. Collector modules are available in 2000, 3400, 5300 and 6000 CFM of air flow capacity, and are easily upgraded with a system retrofit kit to meet changing production requirements. Durable Construction The smaller Econo -Coat 2001 spray booth canopy is constructed of durable, high - performance polypropylene to minimize powder attraction to booth walls and increase coating efficiency. For larger booths where the spray area is farther away from the booth walls, wall panels are constructed of durable, galvanized steel or optional stainless steel to provide easy clean -up and long service life. Clear panel insets are used on select roof panels allowing ambient light into the booth, eliminating the need for special light fixtures. Modular, cost - effective Econo -Coot Series manual powder booth/collector systems meet changing production requirements K..y Y;TMQ Fast Installation, Upgrade and Start-up All Econo -Coat Series collector modules include a tan section, final filters, and electrical control panels, which are factory pre - assembled for fast, easy installation and start -up. Proven Cartridge - filter Technology Nordson filter- cartridge powder recovery systems use a two -step filtration system that eliminates the need for air make -up systems. Cartridge filters are cleaned using a reverse -pulse of air. The vertical cartridge- mounting design ensures effective filter cleaning and provides easy access for filter replacement. Control Features Special control features of Econo -Coat Series powder booths deliver superior operating performance. A solid - state timer allows for adjustment of sequential pulse cleaning to increase filter performance and filter life. A standard differential pressure gauge monitors filtration system performance. A safety interlock switch automatically shuts down the system when air pressure exceeds its normal operating range, indicating filter blinding, to prevent system damage and powder escaping from the booth. Design Considerations Batch Booth Nordson Econo -Coat batch booths are designed for the operator to roll a part or a rack of parts into the booth for coating. General guidelines for selecting the work area are to maintain a minimum two -foot clearance between the top of the part and booth roof. (a) If the operator enters the booth and sprays the part, a clear- ance of four feet should be maintained between the side of the part that is being sprayed and the booth wall. (b) If the operator sprays the part from outside the booth, a clearance of two feet must be maintained between the part and the booth was. • This module sold only with canopy. Other modules available separately. There should be adequate clearance (at least three feet) between the powder collection modules and surrounding objects such as walls, etc., to ensure unobstructed air flow out of the final filters. For ease of reference, a list of standard booth sizes is provided in ascending order by inside work area height (see specifications). Model EC-240I• OPERATOR OPERATOR Calculations a.) (Part/rack height + 1 ft.) x (part/rack width + I (ft.) x (2) = 0 ) sq. ft. b.) Conveyor slot width x length = 0 ) sq. ft. c.) Keyhole height x width x (2) = ( ) sq. ft. d.) Operator opening height x width x number of openings = 0 ) sq. ft. e.) Total square feet of opening x 100 FPM = total CFM required. Model EC Conveyor Booth Econo -Coat conveyor booths are designed for the operator to coat one or both sides of a part and/or rack of parts with a manual spray gun as they pass through the booth. (Automatic powder coating systems must meet stringent safety requirements and require fire detection and suppression systems.) Manual openings allow adequate access to apply powder to passing parts /racks. Part -rack entry and exit openings provide a 6 -inch clearance around the part/rack envelope. Booths are sized to deliver 100 feet per minute of airflow velocity through all booth openings to ensure complete oversprayed powder containment. HANGER ATTACHMENT to properly with its total open area Two standard conveyor can be engineered. 8" PART J CLEARANCE Model EC -53M1 CONVEYOR RAIL 18" F MNUUM CLEARANCE determine a booth's air flow requirements is exhibited below. booths are available. Customized booths REcovED JAN 2 G 2006 PERWRIENTER Model EC 60MI Econo -Coat Module Specifications 1 Hotprin1 11 11 1( (1 \1 1ppro\. 11 eight Ohs.) High effil ienr■ \ lolnr I'rim:m f ilex high elfi, irn, hp la! 2(i" 36 1111;11 1 iller� EC -2001 EC -34M1 EC -53M1 EC -60M I Configurations (a) —460 VAC, 3- phase, 60Hz standard. Othe voltages optional. Model enclosure: Base of module with a durable powder coated finish. Filter cartridges housed in galvanized steel (stainless steel optional) with a powder coated lid. Control panel: Starter, fuses, solid -state timer for sequential pulse cleaning, standard differential pressure gauge and safety interlock switch, Nema -I2 enclosure. UL listed. Automatic reverse air pulsing: delay setting 1.5 —30 seconds, duration setting .05 —.5 seconds. • •Only available complete with canopy. Econo -Coat Batch Booths 111de1 Inside 11ork Area Footprint Number of Module 11 11' 1) 11 11' 1) Modules Configuration EC -2001 EC -3401 EC -6003 EC -5301 EC -6001 EC -3403 EC -5307 EC -3402 EC -5302 EC -5306 EC -5303 EC -5305 EC -6004 EC -5304 EC -6002 Configurations EC- 5301 -C EC- 6001 -C 7' -3" x 5' -9" x 9' -2" 7' -3" x 5' -9" x 4' -9" 8' -3" x 5'4" x 4' -9" 9' -3" x 5' -9" x 4' -9" EC 2001" 5' -0" x 7'-0" x 10' -0" x 8' -0" x 9' -0" x 8' -0" x 12' -0" x 7' -0" x 8' -0" x 10' -0" x 10' -0" 10' -0" x 10' -0" x 10' -0" 8' -O" x 9' -0" x 10' -0" x 5' -0" x 5' -0" 5 ' -0" x 5' -0" 6' -0" x l0' -0" 7' -0" x 10' -0" 7' -0" x 10' -0" 8' -0" x 10' -0" 8' -0" x 10' -0" 9' -0" x 10' -0" 12' -0" x 12' -0" x 12' -0" x 10' -0" 10' -0" 10' -0" 8' -0" x 14' -0" x 10' -0" 9' -0" x 14' -0" x 10' -0" Econo -Coat Conveyor Booths 36" x 60" 30" x 60" 2000 3400 5300 6000 825 775 875 875 7' -3" x 5' -9" x 9' -9" 7' -3" x 5'4" x 9' -9" 10' -3" x 6' -3" x 14' -9" 8' -3" x 7' -3" x I4' -9" 9' -3" x 7' -3" x 14' -9" 8' -3" x 17' -6" x 10' -3" 12' -3" x 17' -6" x 10' -3" 7' -3" x 18' -6" x 10' -3" 8' -3" x 19' -6" x 10' -3" 10' -3" x 19' -6" x 10' -3" 8' -3" x 9' -3" x 10' -3" x 21' -6" x 2l' -6" x 21' -6" x 10' -3" I0' -3" 10' -3" 8' -3" x l5' -0" x 14' -9" 9' -3" x 23' -6" x 10' -3" 8' to 12' (in 6" increments) 8' to 12' (in 6" increments) 3 5 I0 10 \lo(1el Part tine Opening ('au °P) height Number of Manual Guns Options: Stainless steel canopies, powder collection tray on rollers, air manifold. Specifications: I8-gauge galvanized steel mot and wall panels and clear roof panels to allow ambient light into the booth 0 2 6 0 3 3 0 6 1 A 2000 1 B 3400 1 B 6000 1 B 5300 1 B 6000 2 C 6800 2 C 10600 2 C 6800 2 C 10600 2 C 10600 2 C HECEIYED10600 2 CfEY Of TUKWILA) 2 .0 12000 2 J PI r; U 1' 810600 2 C 12000 PERMIT QNTER 1 2 2 3 4 4 Econo -Coals Series Powder Booth /Collector Systems Optional Powder Application Equipment Econo -Coat powder booth/collector systems are designed for optimum performance with Nordson application equipment, such as Sure Coat °, Econo -Coat° and Tribomatic° manual gun systems. Manual powder spray systems feature a corona or tribostatic spray gun, control unit, cable, powder feed hopper and pump. The control units can be mounted on a booth wall or mobile dolly system. The Nordson Sure Coat° System features patented Select Charge° technology for unmatched performance across the widest range of part profiles. Plus, the user - adjustable Automatic Feedback Current (AFC) control to provide maximum operating flexibility to meet a variety of coating requirements including parts with deep recesses and re- coating of already cured parts. The Econo -Coat• Gun/Manual System combines production - proven powder spray gun and AFC control technology and performance in an exceptionally affordable and versatile powder coating package. Nordson powder collection booths and spray systems meet the broadest variety of production requirements, and assure highly efficient, versatile and economical performance. United States Amherst, Ohio Telephone: 800.626.8303 Facsimile: 888.229.4580 Web: www.nordson.com/powder Email: powder @nordson.com www.nordson.com C 2003 Nordson Corporation All Rights Reserved For more information, talk with your Nordson representative or contact your Nordson regional headquarters office. Canada Europe Markham, Ontario Erkrath, Germany Telephone: 800.463.3200 Telephone: 49.211.9205.0 905.475.6730 Facsimile: 49.211.254658 Facsimile: 905.475.8821 Email: powder.systems @de.nordson.com www.nordson.ca • Pre- installed, UL listed, factory tested control panel ensures safe, reliable performance. • Factory preassembled fan assembly and controls ensure fast, easy assembly, installation and reliable operation. Nordson° Japan Tokyo, Japan Telephone: 81.3.5762.2700 Facsimile: 81.3.5762.2701 JAN `r Nordson Corporation • 300 Nordson Drive • Amherst, Ohio 44001 Features and Benefits • Configurable booth modules can be upgraded with optional components to meet a wide range of operating requirements. • Galvanized or optional stainless steel wall panels for high durability and long service life. • High efficiency filters contain powder in the booth as well as prevent fine powder particles from escaping to the work area for a clean, efficient operation. • Clear roof panels eliminate need for special lighting fixtures. • Automatic reverse air pulse cartridge cleaning delivers optimum booth air flow, reliable filter performance and long filter service life. • Differential pressure gauge monitors air pressure increases to detect filter cartridge blinding. • Optional air manifold is available to further minimize installation time. • Safety interlock switch automatically shuts down system when air pressure exceeds its normal operating range to prevent system damage. • Installation and start -up manual provides complete installation instruction with easy -to- read operating and maintenance procedures. • Optional powder tray with rollers helps contain powder that is pulsed off cartridges for greater efficiency and reduced ii iiirep o. maintenance. Nordson reserves the right to make design changes to products to improve their function. These changes may occur between printings. RECEIVED Asia/Australia/Latin America Amherst, Ohio Telephone: 440.985.4000 Facsimile: 440.985.1096 CITY OF TuK MU 24 -hour message service: 440.985.4797 2006 Email: psd_customerservice @nordson.com PERMIT CENTER Mt- 03.1752 Revised 5/03 January 9, 2006 Doug Frohardt Merit Mechanical PO Box 2109 Redmond, WA 98073 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M05 -198 Fatigue Technology — 401 Andover Pk E Dear Mr. Frohardt: This letter is to inform you of corrections that must be addressed before your mechanical permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson, at (206) 431 -3670, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenPer service. If you have any questions, please contact me at (206) 433 -7165. Sincerel encl )10 arshall chnician xc: File No. M05 -198 PNennifer\Correction Letters\2005%105 -198 Correction Ltr #1.DOC jem City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review To: Merit Mechanical - Doug Frohardt From: Dave Larson Date: 01/09/2006 Re: Permit M05 -198 Tukwila Building Division 6300 Southcenter Blvd. Tukwila, WA 98188 206 -431 -3670 An initial Building Department plan review has been completed for the subject project. Please address the following comments with revised plans, specifications, and /or other documentation that will aid us in processing your permit application. Should there be questions on the requirements, please feel free to contact the Building Division office at 206 -431 -3670 1. I visited the site to look at the room where your proposed scope of work was to take place. I was checking for possible fire wall construction that could be affected by the new exhaust and make -up air duct penetrations. The paint booth shown on the submitted plan as existing, however it appears to be new, as installation is not complete. Before we can process your permit, we will need more information about this new paint booth. Please include it in this permit application or a separate permit will be required. If a separate permit application is submitted by another source, please note this on your plan. If you add this to your scope, we will need information including quantities of painting materials used and stored on site and MSDS for each product. I also noted that this paint booth exhausts only through filters and not through ducting to outside. We will need listing information on the paint booth relating to the process and products used. 2. No further comments at this time. 1 ACTIVITY NUMBER: M05 -198 DATE: 12 -16 -05 PROJECT NAME: FATIGUE TECHNOLOGY SITE ADDRESS: 401 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: � Buil ,44-vision Division Public Works Complete Comments: Documents/routing slip.doc 2.28-02 PLAN REVIEW /ROUTING SLIP `PERMIT COORD COPY APPROVALS OR CORRECTIONS: r/( /Va- 1 2 ' 2-2 " ° Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1 2-20-05 Incomplete TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n n Permit Coordinator No further Review Required DATE: DUE DATE: 01- 17-06 Approved ❑ Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Center Use Only CORRECTION LETTER MAILED: 'Q∎• !"1 ( 2 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: n Not Applicable ❑ n ACTIVITY NUMBER: M05 -198 DATE: 01 -13 -06 PROJECT NAME: FATIGUE i FCHNOLOGY SITE ADDRESS: 401 ANDOVER PK E Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ! Bu l.1 g 'vision Public Works Comments: Documents/routing slip.doc 2.28 -02 PERMIT COORD COP PLAN REVIEW /ROUTING SLIP C Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete r1 Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route E Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: n DUE DATE: 01-17-06 No further Review Required DATE: DUE DATE: 02-14-06 Not Approved (attach comments) E DATE: Planning Division Permit Coordinator Not Applicable n C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: w v 0 N 0 w co J w: w 0 . u.a Z Cy I .w z � I- Z I— w uj n o O N o ff w LL•0 Ii Z = . 0 ~. Z Project Name: Fatigue Technology Project Address: 401 Andover Pk E Contact Person: G e( a t` i` �.�eK Sheet Number(s): Entered in Permits Plus on M •( Creatd: si3aReceived s Time Jan. submittal . :48PM Rcvi:od: City of Tukwila Department of Community Development 6300 Southecntcr Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431.3665 Web site; http, / /www.ki.tukwijg,wa.us "Cloud" or highlight all areas of revision including date of revision Received at the City of T ul wila Permit Center by: ( / 1 9 1 1 ,M Date: 1/1 3/ Plan Check/Permit Number: M05 -198 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1. ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions wiU not be accepted through the mail; fax, etc, arry o° TUKWILA JAN 1 3 2006 PERMIT CENTER Phone Number: A25- b 02.-324 Summary of Revision; - . nt ► ►nl @c 4 N by t PC ■iJ DE.R. c OA?' 4G (leo (3y t I . .' / .i p� (4 -sp p�.,� 1.: c_,.140,.. S rn y, Po 4 ti r r e�a_4"et o �tN Asa M S tS d... Pn uiritle v.1" r►t e p � h�eru�•.�ov. t on ver 194--1.4.r. License Information License MERITMII63CM Licensee Name MERIT MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600517946 Ind. Ins. Account Id 46817500 Business Type CORPORATION Address 1 PO BOX 2109 Address 2 City REDMOND County KING State WA Zip 980732109 Phone 4258839224 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/14/1984 Expiration Date 6/1/2007 Suspend Date Separation Date Parent Company Previous License Next License AUTOMMC044QH Associated License Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V Cancel Date 01/01/1980 Bond Amount BRISBOIS, LES C #8 01/01/1980 081S103546895BCM Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #8 TRAVELERS CAS & SURETY CO 081S103546895BCM 07/22/2001 Until Cancelled 512,000.00 03/07/2002 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MERITMI163CM 01/31/2006 TiIC MIME ! MODE1 013011 III,, - ELECINICPL IOW L9S REIMI 9A ELE ITIC L h DIME VaT Talc ME s 1000. DESCRIPTION ED -1 _LOCATION C:Y 1:SP APY 1.0 , Y/PI�/I¢ GOM11Dl REIMS SF - 1 KAMJUKT K8 NIE U FAN 1 DUCT 177 ' 1.0 ' 2580 119 110 - 1 - 60 25 SPEED SWITCH TiIC MIME ! MODE1 013011 III,, - ELECINICPL IOW L9S REIMI 9A _AA ARP DIME VaT PN NZ RAE ED -1 MITSUBISHI PIMA FAN COL 530 710 0.7 1.0 OIRECT 115 1 60 15 53 1 i 1 !I CNC VT . Ei►* EOL P EXN ESP r RT IMO SRI MI6 ooNIC A. A.0. A. P A.► -F AJ•I BF 90T C :P CL.G CD CrG CDNC CON N. CCU • F CA_ i �/ �I • ►�.� ABOVE ACCESS DOOR ACCESS PANEL ABOVE FlWSHED FLOOR AiR HANOUNG UNIT BELOW FLOOR BOTTOM CAST IN MACE CELR4G CEILING DIFFUSER CEILING :fit..' E CEI AG T ANSFER GRILLE CO'VCREIE CONNECTION C.JEIC =tE T PER mINU E EAFFUSER CONN DROWNING CRY BULB t rmiumic s7E • - 1DAPERA7.AE EM:ERPmG WATER TEMPERATURE EQENM DUST ( MINK VATIC PRESSURE FLOOR ✓ cF I rEFT aE4 NRAPE CALE ▪ + emu. Glut saIDOM 1 el PRODUCTION AREA ID E N. WG UN. DIFF. LMN. FT. LWMG LWR MAX_ MOH MN. moT rPQ WTD ai - p4.O_ OSA CBID CO PCF POC PSG RFA PEG IMO • -r - SHIPPING & RECEIVING I i I/ t ' / \I ✓rrrirrir. -Nirrr • WSW DMA TER /DRONtSION AVERT ELEVATION INCHES w.G. LNEJAR DIFFUSER LNEAR FEET /FOOT LOW WAU- GRILLE LOW M..1. REGISTER alsAxaSum 1000 EIRIT1QI THERwY. UNITS LapaiNUIN IAOTORSZED DAMPER MOUNTED MORWALLY '' CASED NORMALLY OPEN CAITSIDE Pit OPPOSED 81UADE DiN4PcJZ CLIME .Duos PR CUBIC FOOT PONT OF CoNECT]ON FORAMS SOIJAli1E MCI+ GAUGE AE..EF �rR REassiR SCOW ;EFT suety AR SOUND ARIED rappgsFut yr TOMIL ANT TOMIGUIN Y�x I WET MUM _ DUCi1MOI (— , 1 0® Oz! 0 R - 100 s - E - 100 f (A3 • t. 1 WARE OUSE -- 135 WAREHOUSE - 130 WAREHOUSE - 109 OD FIRST FLOOR PLAN SCALE: 1/16" = 1' -0" AIR ROW DIRECTION SUPPLY OR OSA DUCT SECnON ARP OR -ON RD RROL . RECTANGULAR R£ RJRic R£L+EF OR DtOAILAST DUCT Seam L P OR 'ONIARD ROUND. RECTAMGLA AR SUPPLY OR OSA DUCT BECTON D01IRN OR AMY POUND. RECDWICUAR RERAN. RE LIEF OR OO*&6T DUCT =nom DOOM OR AMY PROM Rowe. RECTANGULAR ROUND DUCT SMOCK. /y , cFw SUPPLY A2 RUINER «o•a: ES CFM Q ANnnr E)osiluST - mUNM R PORDUES CF N CILANTIMY mom 111IR>•10 MOM 41Smix WSW 10 SOME IS PRIM sl>O E 14 MSS 4 - 4 Ann wCMom a • DEMO 108 a 4 4 1/ DISPLAY — 106 WAREHOUSE — 133 , i lLAB TEXT — TEXT LAB — 131 WAREHOUSE - 160 ;j 4"--1-1.Y a =+ 1; • e SQOPE OF WORK INSTALL 1.5 -TON SPLIT SYSTEM. INSTALL DI UST DUCTWORK FROM OWNER SUPPLIED WEN W!TH DI/.UST FAN. INSTALL MAKEUP MR TRANSFER GRILLE •TH 3011 FLI.TEL INSWl CONOENSATE PUMP 10 PUMP CONDENSATE TO ROOF. INSTALL THERMOSTAT WITH CONTROL WRING LEGAL DESCRIPTION mica 10223400050 CONDENSING UNIT SCHFDUj„E FAN COIL SCHEDULE CONDENSATE PUMP SCHEDULE SUPPLY FAN SCHEDULE M -1.0 HOC PUN - W W FLOOR SRE LOCATION NOTES: 1. WITH LOM /H PRESS SWIr1tI CRANKCASE HEATERS, LOW AMHIDIT. COMPLETION AND CO)AMISSIQN,ING FOR MECHANICAL SYSTEMS 1. VERIFY LOCATIONS OF THERMOSTATS WITH OWNER. 2. CONDENSATE DRAINS TO BE DISCHARGED ON ROOF. 3. USE TOTAUNE SIGNATURE jCPV230 7 -DAY PROGRAMMABLE THERMOSTAT. TAG CU-1 MAKE & MODEL 1111SUSISIR PU18EK OESCRPRON OONCOISPC UNIT COOLING, 101 18.5 REGRIG. PIPE UO. SUCT. 3/8' S /8' OUTDOOR FAN VOLT PM H= M 208 1 60 0.75 COMPRESSOR VOLT PH H: RA L1AIA 208 1 60 12.0 37.0 EER 10.6 ELECTRICAL WEIGHT . VOLT PH MCA 40C1 L8S REMARKS 460 3 18.2 30 154 1 RECORD CRAMS OF ACTUAL INSTALLATION SHALL 8E PRONDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WASH. STATE OIERLET COOS (WSEC) SECTION 1416.1 AN OPERATION MANUAL AND MANTDMNCE WMyAL SHALL BE PRIMED TO THE BOLO OWNER PER *SEC SECTION 1416.2 ALL MC SYSTEMS SMALL BE BMANCED AND A "MITTEN BALANCE REPORT SIMLL 8E PR01+DED TO THE OWNER PER WSEC SECTION 1416.3. WPC CCARROL SYSTEM 9041 BC !taw). CALIBRATED AND ADJUSTED. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE MAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS. AND IMPUTE REPORT OF TEST RESULTS SHALL EE FRED MI1H DIE OWNER PER WSE+C SECTION 1416.4.1. AND 1416.4.2 By ALI ROM Pen* Pin. Jitarkg.00 PMe v appall Is siejset Is Mtn ay Sololms Appeal M doss Not aulkeilli the vbit m of err? accepted code or MONO ..1 "eV•- � aid . � • (--31- oC Clty 1111111111111916 OMEN S.:' • V — - - • . � - fi t e � BUILDING ✓a tf S :'aft.4 oe game -c c :. r:= _._ - t ' - - � � : - - t'd .. •t- ..'.�� - . . i ►'^fin --- ' a kccrukone CL- . +t ZC - Eii v ZE 0 0 0 W CID Is- J iERIT IECHAMCAL MAC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 (425) 883 -9224 FAX (425) 867 -0962 LICENSE: MERITMI163CM nvosioNS 1. ma FOR POW 12/13/06 - GI 2. NCORP'rOPMED REVEP COIiENTS 1/13/06 - GO COPYRIGHT NOTICE. THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, Al'[. MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT AN'e UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. IIIMET mut GJF AEA — 2/!2/05 305396 HVAC MAI FLOOR W1.0 • 1 —Or -1 401 ANDOVER PARK EAST TUKWILA, WA 98188 P18P ELECTRON. _ TAO ME s MTV. OESCAPIO l TYPE HP (PA FT VOLT PM lit RE AMS P -1 LITTLE CANT 48107 CONDENSATE PUMP CENTRIGUFUGAL 1/50 25 15 115 1 60 i 1 !I CNC VT . Ei►* EOL P EXN ESP r RT IMO SRI MI6 ooNIC A. A.0. A. P A.► -F AJ•I BF 90T C :P CL.G CD CrG CDNC CON N. CCU • F CA_ i �/ �I • ►�.� ABOVE ACCESS DOOR ACCESS PANEL ABOVE FlWSHED FLOOR AiR HANOUNG UNIT BELOW FLOOR BOTTOM CAST IN MACE CELR4G CEILING DIFFUSER CEILING :fit..' E CEI AG T ANSFER GRILLE CO'VCREIE CONNECTION C.JEIC =tE T PER mINU E EAFFUSER CONN DROWNING CRY BULB t rmiumic s7E • - 1DAPERA7.AE EM:ERPmG WATER TEMPERATURE EQENM DUST ( MINK VATIC PRESSURE FLOOR ✓ cF I rEFT aE4 NRAPE CALE ▪ + emu. Glut saIDOM 1 el PRODUCTION AREA ID E N. WG UN. DIFF. LMN. FT. LWMG LWR MAX_ MOH MN. moT rPQ WTD ai - p4.O_ OSA CBID CO PCF POC PSG RFA PEG IMO • -r - SHIPPING & RECEIVING I i I/ t ' / \I ✓rrrirrir. -Nirrr • WSW DMA TER /DRONtSION AVERT ELEVATION INCHES w.G. LNEJAR DIFFUSER LNEAR FEET /FOOT LOW WAU- GRILLE LOW M..1. REGISTER alsAxaSum 1000 EIRIT1QI THERwY. UNITS LapaiNUIN IAOTORSZED DAMPER MOUNTED MORWALLY '' CASED NORMALLY OPEN CAITSIDE Pit OPPOSED 81UADE DiN4PcJZ CLIME .Duos PR CUBIC FOOT PONT OF CoNECT]ON FORAMS SOIJAli1E MCI+ GAUGE AE..EF �rR REassiR SCOW ;EFT suety AR SOUND ARIED rappgsFut yr TOMIL ANT TOMIGUIN Y�x I WET MUM _ DUCi1MOI (— , 1 0® Oz! 0 R - 100 s - E - 100 f (A3 • t. 1 WARE OUSE -- 135 WAREHOUSE - 130 WAREHOUSE - 109 OD FIRST FLOOR PLAN SCALE: 1/16" = 1' -0" AIR ROW DIRECTION SUPPLY OR OSA DUCT SECnON ARP OR -ON RD RROL . RECTANGULAR R£ RJRic R£L+EF OR DtOAILAST DUCT Seam L P OR 'ONIARD ROUND. RECTAMGLA AR SUPPLY OR OSA DUCT BECTON D01IRN OR AMY POUND. RECDWICUAR RERAN. RE LIEF OR OO*&6T DUCT =nom DOOM OR AMY PROM Rowe. RECTANGULAR ROUND DUCT SMOCK. /y , cFw SUPPLY A2 RUINER «o•a: ES CFM Q ANnnr E)osiluST - mUNM R PORDUES CF N CILANTIMY mom 111IR>•10 MOM 41Smix WSW 10 SOME IS PRIM sl>O E 14 MSS 4 - 4 Ann wCMom a • DEMO 108 a 4 4 1/ DISPLAY — 106 WAREHOUSE — 133 , i lLAB TEXT — TEXT LAB — 131 WAREHOUSE - 160 ;j 4"--1-1.Y a =+ 1; • e SQOPE OF WORK INSTALL 1.5 -TON SPLIT SYSTEM. INSTALL DI UST DUCTWORK FROM OWNER SUPPLIED WEN W!TH DI/.UST FAN. INSTALL MAKEUP MR TRANSFER GRILLE •TH 3011 FLI.TEL INSWl CONOENSATE PUMP 10 PUMP CONDENSATE TO ROOF. INSTALL THERMOSTAT WITH CONTROL WRING LEGAL DESCRIPTION mica 10223400050 CONDENSING UNIT SCHFDUj„E FAN COIL SCHEDULE CONDENSATE PUMP SCHEDULE SUPPLY FAN SCHEDULE M -1.0 HOC PUN - W W FLOOR SRE LOCATION NOTES: 1. WITH LOM /H PRESS SWIr1tI CRANKCASE HEATERS, LOW AMHIDIT. COMPLETION AND CO)AMISSIQN,ING FOR MECHANICAL SYSTEMS 1. VERIFY LOCATIONS OF THERMOSTATS WITH OWNER. 2. CONDENSATE DRAINS TO BE DISCHARGED ON ROOF. 3. USE TOTAUNE SIGNATURE jCPV230 7 -DAY PROGRAMMABLE THERMOSTAT. TAG CU-1 MAKE & MODEL 1111SUSISIR PU18EK OESCRPRON OONCOISPC UNIT COOLING, 101 18.5 REGRIG. PIPE UO. SUCT. 3/8' S /8' OUTDOOR FAN VOLT PM H= M 208 1 60 0.75 COMPRESSOR VOLT PH H: RA L1AIA 208 1 60 12.0 37.0 EER 10.6 ELECTRICAL WEIGHT . VOLT PH MCA 40C1 L8S REMARKS 460 3 18.2 30 154 1 RECORD CRAMS OF ACTUAL INSTALLATION SHALL 8E PRONDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WASH. STATE OIERLET COOS (WSEC) SECTION 1416.1 AN OPERATION MANUAL AND MANTDMNCE WMyAL SHALL BE PRIMED TO THE BOLO OWNER PER *SEC SECTION 1416.2 ALL MC SYSTEMS SMALL BE BMANCED AND A "MITTEN BALANCE REPORT SIMLL 8E PR01+DED TO THE OWNER PER WSEC SECTION 1416.3. WPC CCARROL SYSTEM 9041 BC !taw). CALIBRATED AND ADJUSTED. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE MAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS. AND IMPUTE REPORT OF TEST RESULTS SHALL EE FRED MI1H DIE OWNER PER WSE+C SECTION 1416.4.1. AND 1416.4.2 By ALI ROM Pen* Pin. Jitarkg.00 PMe v appall Is siejset Is Mtn ay Sololms Appeal M doss Not aulkeilli the vbit m of err? accepted code or MONO ..1 "eV•- � aid . � • (--31- oC Clty 1111111111111916 OMEN S.:' • V — - - • . � - fi t e � BUILDING ✓a tf S :'aft.4 oe game -c c :. r:= _._ - t ' - - � � : - - t'd .. •t- ..'.�� - . . i ►'^fin --- ' a kccrukone CL- . +t ZC - Eii v ZE 0 0 0 W CID Is- J iERIT IECHAMCAL MAC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 (425) 883 -9224 FAX (425) 867 -0962 LICENSE: MERITMI163CM nvosioNS 1. ma FOR POW 12/13/06 - GI 2. NCORP'rOPMED REVEP COIiENTS 1/13/06 - GO COPYRIGHT NOTICE. THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, Al'[. MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT AN'e UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. IIIMET mut GJF AEA — 2/!2/05 305396 HVAC MAI FLOOR W1.0 • 1 —Or -1 401 ANDOVER PARK EAST TUKWILA, WA 98188