Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M04-012 - SOUTHCENTER MALL - FOREVER 21
FOREVER 21 826 SOUTHCENTER MALL M04 -012 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Tenant: Name: FOREVER 21 Address: 826 SOUTHCENTER MALL, TUKWILA WA MECHANICAL PERMIT Parcel No.: 2623049004 Permit Number: M04 -012 Address: 826 SOUTHCENTER MALL TUKW Issue Date: 05/19/2004 Suite No: Permit Expires On: 11/15/2004 Owner: Name: 3G SOUTHCENTER LTD Phone: Address: 25425 CENTER RIDGE RD, CLEVELAND OH Contact Person: Name: CHRIS MCCOMAS Phone: 310 328 -6300 Address: EXPRESS PERMITS, 1327 POST AV, STE H Contractor: Name: PACIFIC AIR CONTROL INC Phone: Address: 11812 N CREEK PKWY N 104, BOTHELL WA Contractor License No: PACIFAC230P8 Expiration Date:10 /01/2005 DESCRIPTION OF WORK: REMOVING FIXTURES AND EQUIPMENT. REMOVING, ACTIVATING AND /OR RE- ACTIVATING LINES AS NEEDED. INSTALLING (2) TEN TON SPLIT TRANE HEAT PUMPS TO REPLACE THE EXISTING ONES RUN AIR DISTRIBUTION SYSTEM. Value of Construction: $21,300.00 Type of Fire Protection: SPRINKLERS Permit Center Authorized Signature: The granting regulating c Signature: doc: Mech $127.00 Uniform Mechnical Code Edition: 1997 Fees Collected: Date: .7 is —d c I hereby certify t •t I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances gov ing t w• will •e complied with, whether specified herein or not. resu - to give authority to violate or cancel the provisions of any other state or local laws rk. I am authorized to sign and obtain this mechanical •ermi Print Name: E P-CCkU-12.D V .-G b. irct Lam. M04 -012 Date: 4s This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 05 -19 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049004 Permit Number: M04 -012 Address: 826 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 01/27/2004 Tenant: FOREVER 21 Issue Date: 05/19/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 13: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 15: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) doc: Conditions M04 -012 Printed: 05 -19 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 16: Duct detectors shall send a supervisory signal only upon activation. 17: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 18: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 19: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 20: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) 21: Local U.L. central station supervision is required. (City Ordinance #1900) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 23: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) 24: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) doc: Conditions * *continued on next page ** M04 -012 Printed: 05 -19 -2004 Signature: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating constru ' ion • r the ' - rfor • anr f work. Print Name: 12 ' k c t ° > 4 f- - r - C 1 " 4/1 --C-- 11 ""‘ M04 -012 Date: s 4 c b4 Printed: 05 -19 -2004 Site Addressa YOUhCEd mt-t — Tenant Name: &REVE2 9-) Property Owners Name: 1 r e, kit t -E, I U�0 ,f /, Mailing Address: I !lop/ W i 5 i /3 I re, 11 .d- Lo 4 s. cit3 Name: Cl'lr IS Mc (_O Mailing Address: OS /3 Q'7 Pas 7 /TVL- E -Mail Address:al rISr»P Cbpr ee rrn I IS. Carr) Contact Person: E -Mail Address: * *C ' O E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: kapplicationstpennit application (3.2003) 3/2003 CITY OF TUKWILA Community Development Department Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** �0 Company Name: w Mailing Address: jO3'7 ry 6 31/40 /6r)120-' Contact Person: ) O Y'C'S ` �'a') .oka, S1H oalak 81 Page I King Co Assessor's Tax No.: 26 1.0g 6 1004 Suite Number: S Floor: New Tenant: .... Yes ,K..No rte« • :! .. -�:.,� . atn edtiy Day Telephone: 3/0 • '' c9F • 63C0 T rr arleP, C' fi 9o.s City State Zip Fax Number: 3/ 396 3 6 Company Name: Mailing Address: City Day Telephone: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ` ecoh _ Fax Number: MECH q,ccfL- State State 9 2 ? S� Zip Zip City • J State Zip U Day Telephone: ...W hk . 9 / > i ISIPINEF�Ii i'.0 'I C. F` 3 ; :Y �N"� ; �x ''� efs:rS %} i` 1 s e �tY� •.. Zip City Day Telephone: Fax Number: State UnitiTYPp, :: ∎,.., ,., .. k ;� ' a . Qty, ,'UOit?TY.11 "0 .. , . 6 ,0 ... QtY tul�if` YPe ' >! v .. Qt i . `Boiler /Comp r _.. ... . essor Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System , 30 -50 HP /1,750,000 BTU Appliance Vent ( Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System 1 Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind t MECHANICAL CONTRACTOR INFORMATION in f0 Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: Scope o Work (please provide detailed information): State Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 2.I 1 300 A - Zip Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ....55 Fuel Type: Electric ❑ Gas ....E] Other: Indicate type of mechanical work being installed and the quantity below: 4 0 lf��',i� 9 s �.i' ' 'k441i2a:'.' .�:�k ttle, .r�. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject " to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR AUTH i RIZE r GENT Signature: C i I Print Name: Mailing Address: Date Application Expires: 7--Z 7- a Y Date Application Accepted: I Z7 -O f/ \applicationsVennit application (3.2003) 3/2003 1 s , uE E h %rrar&e Page 4 Date: //�4/0 Day Telephone: 2/ 5 9-5• 2 300 nil 9o s�r City State Zip Staff II it City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049004 Permit Number: M04 -012 Address: 826 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/27/2004 Applicant: FOREVER 21 Issue Date: Receipt No.: R04 -00507 Payment Amount: 127.00 Initials: SKS Payment Date: 04/29/2004 11:03 AM User ID: 1670 Balance: $0.00 Payee: J. R. LENNEN CONSTRCTION, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 07977 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT 127.00 Account Code Current Pmts 000/322.100 101.60 000/345.830 25.40 Total: 127.00 0.; ?-t -04/30 9716 TOTAL 127.00 : doc: Receipt Printed: 04 -29 -2004 I . Pro' ct: ( cNev & k Type of t tit Ad sa rC` \ Al ( Date Called: 1 i —OLf Special Instructions: Date Wanted: '1 -- I c- -- b L 1 a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20 )431 -3670 .Approved per applicable codes. Corrections required prior to approval. COMMENTS: C! cw'e 5 Qcr) - 1 g4P v Q�cr"4t e " ri n1� 'Date REINSPECTION FEE EQUIRED. Prick to inspection, fee must be at 6300 Southcenter Blv•., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Pror:i5Le V - Pk 21 Type of Insnectipn: . - „ Inc,. sc a4a(1 Date Called: 1 .5-1 01. 1 Special Instructions: Date Wanted: 0 Requem 14- 4.M• e kr Phone No:, U I INSPECT ON NO. INSPECTION RECORD Retain a copy with permit PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 ye' ] Approved per applicable codes. Corrections required prior to approval. COMMENTS: „,...,/,...x 2t c , 4-'411 /_.../.., 62-0 I-4 z-- f -, e.-e / . . 7 1° I 4-7 , it- • ill c-eA-ei /i 6 -r El $47. REINSPECTION E REQUIRED. Prior to inspection, fee mu be I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Pr ct L /, �' T � '` of ins 4tio�: j) ` �� A te t Q S C , Mal( Date Ca ed: 70 0 y Special` � � uctions: � t W CA w ` ' -1-ifInk uil l 1-n �� .' Date Wanted: �( a.m. Requester: 4 1-- � LI - - 12 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 proved per applicable codes. Corrections required prior to approval: COMMENTS: 1 Date: 7 �� $47.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee mu be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: v. _.,. i`y �tl.�3. _ik'::r'. 't li ':44.c� :: <. :; -h�f: Pr ectt: /� V 1� U e . 2 � Type of In ection: 'v] � ( 4/ 0 1 +l Ad s :: Date Call d: p i Special Instructions: Date Wanted: i n a. Requester: Phone DIL(41 5,--i r 075/g .. INSPECTION RECORD Retain a copy with permit INSPECT! • N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Approved per applicable codes. $47.00 REINSPECTION E REQUI ED. Prior to inspection, fee must b paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: Date: . W, Corrections required prior to approval. ri • 7 =. 0 0 t v1 w: J o • W g a N a W ., Z � W j W. O c o 0 l— W W V P. l! ! Z .O ~ z P : eAfe't Z 1 Type of ection: 0 CA A ( f) Addres,s4, Date Cal ed:6( I-1 I 0 Special nstructions: Date Wanted: Request t U)D i ti450— Phone NV r A9 1 i 4. c0--A-S2 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4313670 rZi kpproved per applicable codes. INSPECTION RECORD Retain a copy with permit Vhf)i PER ITdNO. Corrections required prior to approval. COMMENTS: Dote: 2. 2_ 47.00 REINSPE ON FEE REQU ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., S ite 100. Call to schedule reinspection. Receipt No.: Date: Project: 'Type of spection: AddreV Date Called: Special Instructions: ' 3 r Date Wanted:, a.m. Requester: Phone No: -7 Ma -e2 $47.00 R INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 431-3670 COMMENTS: • ne-1.1: 'Inspector: 14 I Date. 6 (- 6 7 '0 Approved per applicable codes. El Corrections required prior to approval. 'Receipt No.: 'Date: ProjeSt — %/ / 61/.0r � , Type of Insftion: .rdub// - /N. Address: Date Called: Special. Instructions: Date Wanted: 6 Flo 0 4f a.m. X.m Requester: D.-1/11/4- Phone No: 7/ c/- 23s' - /7y INSPECTION RECORD Retain a copy with, permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7.00 REINSPECTIOP FEE REQUIRED Prior to inspection, fee must be i' paid at 6300 Southcent Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: Date: Proje ,f ( ? � Type of Inspection: J /; A: d'� . K" %(' / 1'1 Addres ,-,,s=1-1' i? /i ^ fir. ' ., �. Date Called: 6 � D `/ Special Instructions: . Date Wanted -/5 y a.m., gir Requester: .26 /e Phone No: 2 6 ' > :3 ? 7) 9/ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 'Inspector INSPECTION RECORD Retain a copy with permit /) 2/Z PER T, 206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4 re. s-4 12) rocl( J v\ s )1)3_ (Date:S El $47.00 REINSPECTION FEE• REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Proje Type of I ection: b IA 1 Addrss: Date Called: Special Instructions: Date Wanted: 11 i fp I IDLi a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECT110 NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. (206)431-3670 Corrections required prior to approval. COMMENTS: k<e —e4 aAe x. trii • ■"' Inspect°, D$47. REINSPECTIO EE REQUIRED. Prior to inspection, fee m st be paid at 6300 Southce er Blvd., Suite 100. Call to schedule reinspection. r eceipt No.: 'Date: Pro' c : TO C Type of Insp ti , n: . (A Ad Date Called: mlatf Sped nstructions: Date Wanted: 0 � � Re ster / VC/K d) Pho I cr, — . 3) — 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /y c:g "1" Dat6 Ej S47.60 REINSPECTIbN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: Date: Pr• • • t: r►L' L. Type of Inspection: Addr s: /� �`` r � 1 Date Cal ed.- 7/ --1 Special Instructions: Date Wanted: i C) L( a.m. errrr, Requester: � (i ! 1„)(A44A, Phon o Ili- G INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ' Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: O C� .(A El S47. REINSPECT N FEE REQUIRED. Prior t inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pro `— ) ., t 41 I Type of Inspe ion: (•C f t A e Date Called e -19 (,- oq Special Instruc ions: Date Wanted: LP JD a, Requester: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 15 - 414eproved per applicable codes. El Corrections required prior to approval. COMMENTS: (D A- uvj 44- A-R t.� L I 13 ,a \A ;1 Sc.3,aov .00 REINSPECTIO FEE REQUIRED. Pri r to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. all to schedule reinspection. (Receipt No.: 'Date: tor: _ A A--cam -)."0"" Date: 7 r,oj ect Name rn fe%J er , / Address �'' h �6(.4 14 or I , Suite # Retain curren_.inspect,ion _schedule ._ _, Needs shift inspection ApprciVed without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: fr Halon: Pre -Fire: Permits: 1_, `?authorized Signature FINALAPP.FRM v-tf/ (1,713,44, ritAci au* , ;A.d' e • �, v$ �. i.: City of Tukwila Fire Department Thomas P Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 Steven M. Mullet, Mayor Permit No. ` I 0- 0 f ' , • 7/%4Ayi Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575-4404 • Fax: 206 -575-4439 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M04 -012 PROJECT NAME: FOREVER 21 SITE ADDRESS: 826 SOUTHCENTER MALL DATE: 01 -27 -04 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #_ Revision # after /before permit is issued DEPARTMENTS: 4 AW( 3 -2 -o .5/0 ,q / -3&c'l Buildi Division 0 Fire Prevention 0 Public Works El Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01 -29 -04 Complete [' Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROyTING: Please Route , L!I Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 02 -26 -04 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [✓� Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slIp.doc 2-28-02 PERMIT COORD COPY LICENSE DETAIL INFORMATION Form Page 1 of 2 LICENSE DETAIL INFORMATION Current Filter: None STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: Registration# or License PACIFAC230P8 Name PACIFIC AIR CONTROL INC Address 11812 N CREEK PKWY N 104 Address City BOTHELL State WA Zip 98011 Phone Number 2066826393 Effective Date 10/28/1977 Expiration Date 10/1/2005 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code AIR CONDITIONING Other Specialties AIR HEAT,VENTILATION,EVAPORAT UBI Number 601298907 *VIEW CROSS REFERENCE FILE FOR THIS LICENSE* * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY , NAME , PRINCIPAL OWNER NAME , LICENSE , UBI NUMBER , check the JAI Contractor Industrial Insurance Premium Status or return to the L841 Construction Compliance Home Page https://wws2.wa.gov/lni/bbip/TF2Form.asp?License=PACIFAC230P8 05/19/2004 N W w Q a 1412.54157..-0311 tit /01 '1N3Wn00a 3H1 AO kinvno 3H1 al. 3la si ll 30110N SIHi NVH,021V310 SS31 SI 3VW Id SIH1 NI 1N31/1f1300 3H1 Al :33110N WAS REGISTERED AS PROVIDED BY LA CCONST SPECIALTY t :._ �pGIST. 1p�0 X2005 ccMA PACIFA C230p8 EFFECTIVE DATE 10/21311977 01 05 gOL INC* 1181 14 CREEK. CREEK PICA I31Q4 980.11f BOTHELL. -- Issue OP LABOR AND INDUSTRIES INDUSTRIES Issued U) Please Remov An d Sign identification Card Before Placing in Billfold r4 3 4' 9 • HVAC SYMBOL LEGEND kg licec.) N ZVI NOTE'S T TITUS 1. 3 2 NOTES: 1. SUPPLY AR DIFFUSER WITH OPPOSED BLADE DAMPER 2. 1/2' X 1/2" X 1/2' =CRATE RETURN MR GRILLE 3. PIIORIZ RASTER FRAME FOR DIFFUSERS N GYP. COMO. E-+ Aar PANEL r 7 7 1 K I L_' �•I V AMR UNDER NEGATIVE PRESSURE MANUAL VOLUME DAMPER FLEXIBLE DUCTWORK - 5' -0' MAX. REVISION TRIANGLE O KEY NOTE THERMOSTAT DUCT SMOKE DETECTOR WORM DAMPER SCHEDULE OF DIFFUSERS, REGISTERS AND GRILLES kg licec.) N ZVI NOTE'S T TITUS 1. 3 2 NOTES: 1. SUPPLY AR DIFFUSER WITH OPPOSED BLADE DAMPER 2. 1/2' X 1/2" X 1/2' =CRATE RETURN MR GRILLE 3. PIIORIZ RASTER FRAME FOR DIFFUSERS N GYP. COMO. • 0 s I MECHANICAL PLAN FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con - tractor's copy of approved plans acknowledged- , 40, o' AT il ntIrt Date Permit No. 1�1 _ _ - To © 110 .v� - " ',t ClIktitSIS "` fit. :. E.At " DtVi L "Lonfresi.:314. fuel soca fall. HEAT LOSS HEAT GAIN SUMMARY • -_ 1► OUTSIDE WALL: 0 OUT'SME Mt 1520 x 4S ,T ... ': - i ;_.t . x 1.0115 4 11 . 1111 Mt -71-s- SIIMID 10%. WS 411 0 ev u 79000 MU 0 IITUI UGHTNG 20375 OIRTTS N PEOPLE x 230 OUTSIDE AMR: 1520 100000 BTU 24000 /R1 11000 /IN :.:-::: 902430 ITN « TIN IS A SUMIIMMr LOD CALOIA111011 BR2ED ON GU1PUT NM WRIER MOCK L PROSTMII MR111011 ],011). WSW GUMS Mt /M AR AISLE UPON RIONIPT. SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ELECTRICAL ❑ LUMBING eirGAS PIPING CITY OF TUKWILA BUILDING DIVISION • DX FAN COIL UNIT WITH ELECTRIC HEAT SCHEDULE :•1111 40RM1 012 Lei= .1111111:1.4. 425 v. 1000 .. l Ell MO MI MIN 1040 � � � iT•.l� � a . t � NEJE • 4 3.7 sJ.e.Y.LJ 111111111E1111110 E..:JLIL..:] tE 2 NX121IORMk 1. FACTORY SUPPLED ALTEMM I FAIN MOM 2. RCM SUPPLIED IL1ERNTE OM ASSY. 3. OYEIIP EAD IUSP ANON PRANK. AOCONIIIIM 1. °MINS'MLTR CM NUR' PROWL 2. JMTILIMMQTIC NEW. • MECHANICAL KEY NOTES QQ 1. NEW SPLIT SYSTEM FM CON. UNIT AND CONDENSING UNIT. 2. LOCATE AR HWIDLNG UNIT N BEST POSSIBLE LOCATION. LOCATION ON DRAWINGS IS APPR0D0MATE ONLY. ABIDE BY MANUFACTURER'S CLEARANCE RECOMMENDATIONS. SUSPEND FROM STRUCTURE ABOVE WTTH VIBRATION ISOLATORS. PROVDE 2' DEEP GALVANIZED SECONDARY DRAIN PAN. EXTEND REFRIGERANT PIPING TO CONDENSING UNIT ON ROOF. VERIFY LOCATION WITH LANDLORD'S REPRESENTATIVE 3. REMOVE COMM CONDOMS UNIT MD REPLACE MTH NEW AS COORDINATE LOCATION WITH LANDLORD'S REPRESENTATIVE 4. EXTEND 1' PRIMARY MD OVERFLOW/ CONDENSATE LINES TO DISCHARGE AT FLOOR SINK. ENSURE PRIMARY CONDENSATE PIPE INSTALLED WITH MN. 4' DEEP P -TAP. LABEL LINES ACCORDINGLY. DO NOT COMBINE. 5. RETURN AR OPENING ON TOP OF FAN COL UNIT(S). 6. CONNECT RETURN MR DUCT TO AR IMNDLNG UNIT WITH FLEXIBLE CONNECTION. 7. EXTEND 14/14 OUTDOOR AMR DUCT TO LANDLORD'S OUTDOOR AIR MINI AND MAKE CONNECTION. 5. T -STAT - MOUNT AT 4'-0' A.F.F. 9. SEE PLUMBING G PLAN MD RISER DIAGRAMS ON SHEET MM2.O FOR PLUMBING WORK N THIS AREAL` 10. FANLIGHT COMBINATION BY ELECTRICAL CONTRACTOR. DUCTWORK BY MECHANICAL CONTRACTOR. 100 CFA. 11. EXTEND 6U • EXHAUST DUCT UP THROUGH ROOF AND TERMINATE MTH ROOF CAP AND BIRDSCREDL MEV ROOF PENETRATION & ROUTING WITH LANDLORD'SREPRESENTATIVE 12. RELIEF AR TO MALL COMMON MET. 13. ACCESS PANEL SHOWN FOR REFERDCE ONLY. COORDINATE SIZE A LOCATION WI ARCHITECT. 14. MOUNT ROUND DIFFUSERS AT APPROXIMATELY 12'-O' A.F.F. COORDINATE HEIGHT WI ARCIITECT. NO FLEX DUCT PERMITTED IN SALES AREA. (TYP.) 15. SUPPLY AR DUCTS BELOW GYPSUM/ BOARD CELNG AT APPRONIIMTELY 12'-0 AF.F 16. SUPPLY AR DUJCT PENETRATES VERTICAL BULKHEAD IN THIS AREA. DUCT ON THIS SIDE 15 ABOVE GYP. ORD. COUPS. 17. SUPPLY AIR DUCT PEIETRAIES IN G � 1 BULKHEAD THIS AREA. DUCT ON THIS SIDE IS BELOW BRO. CEILING. AIR COOLED CONDENSING UNIT SCHEDULE 3. WNW MIT TAT. 4. UR *MEW COMM PRCETAEL r SPECIAL NOTE !VAC CONTRACTOR TO INSTALL DUCTWORK ACCORDING TO PLAN TO ENSURE DUCTWORK DOES NOT CONFUCT WITH WHIM. ALSO, 10/AC CONTRACTOR TO ENSURE AR FROM DFFUSERS IN DRESSING ROOM AREA DOES NOT INTERFERE MTH DRAPERY AT ENTRANCE TO DRESSING ROOMS. HVAC CONTROLS H OPEW ELL 17300F 2010 MTH 0730011 2029 COMMERCIAL SUBBASE AND T0512A 1009 VDR AGLMRD CLEAR LOCKING COMER. OR APPROVED EQUAL. 7-DAY PROGRAMMABLE MULTI -STAGE HEATING/COOLING AUTOMATIC CHANGEOVER THERMOSTAT TO CONTROL TIE OPERATION OF EACH NT. MOUNT THEFlMM05TAT AT 4'-0" A.F.F. SEDLIMICLALAZEBMI SPUT SYSTEM. DX COOLING WITH ELECTRIC HEAT COOLING CYCLE - OCCUPIED HOURS: UPON A RISE IN SPACE 'T ATURE ABOVE THE OCCUPIED COOLING SETPOINT OF THE THERMOSTAT. THE REFRIGERATION SYSTEM SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. THE SUPPLY FMI SHALL OPERATE CONTINUOUSLY. THE OUTDOOR AIR DAMPER SHALL BE OPEN TO TIE MINIMUM POSITION. THE RETURN AR DAMPER SHALL BE FULLY OPEN. HEATING CYCLE - OCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE OCCUPIED HEATING SETPOINT OF THE THERMOSTAT. THE ELECTRIC HEATING COL SHALL CYCLE AS RE DURED TO MAINTAIN SPACE TEMPERATURE AT THE THOIMIOSTAT SETPOINT. THE SUPPLY FAN SHALL OPERATE CONTINUOUSLY MD THE OUTDOOR MR DAMPER SHALL BE OPEN TO THE MINIMUM POSITION. THE RETURN AR DAMPER SHALL BE FULLY OPEN. COOLNG CYCLE - UNIOCCUPED HOURS: UPON A RISE IN SPACE TEMPERATURE ABOVE THE UNOCCUPIED COOLING SEIPOINT OF THE THERMOSTAT. THE REFRIGERATION SYSTEM SHALL CYCLE AS REQUIRED TO MMfUN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. THE SUPPLY FAN SHALL CYCLE AS REQUIRED MD TIE OUTDOOR AR DAMPER SHALL BE CLOSED. TIE RETURN AIR CAMPER SHALL BE FULLY OPEN. HEATING CYCLE - UNOCCUPED HOURS: UPON A DROP IN SPACE TDrPERA URE BELOR THE UNOCCUPIED HEATING SETPOINT OF THE THERMOSTAT, THE ELECTRIC HEATING COIL SHAD. CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. THE SUPPLY FM SHALL CYCLE AS REQUITED AND THE OUTDOOR AR DAMPER SHALL BE CLOSED. THE RETURN MR DAMPER SHALL BE FULLY OPEN. SPECIAL MECFIANICAL NOTE: THESE ORAAM>I NGS ARE SCHEMATIC N CHARACTER AND MIDST NOT BE SCALED. THE CONTRACTOR SHALL FIT THE WORK 10 THE JOB. CAREFULLY INVESTIGATING THE STRUCTURAL,. O CTRICAL. ARCHITECTURAL SPACES AND FINISH CONDITIONS AFFECTING DE WORK ACCORDINGLY AND FURNISHING N DXSSSARY BEADS. OFFSETS, • AND FITTINGS. JUNCTIONS ETC.. %WEINER OR NOT SPECIFICALLY SHOW/4 OR CALLED FOR, AND SEE THAT THERE ARE NO INTERFERENCES BETWEEN THIS WORK AND THE WORK OF ANY OTHER TRADE 0 • GENERAL MECHANICAL NOTES A. THE CONTRACTOR FOR THIS DIVISION OF WORK MS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPON'SNEE FOR THE COORDINATION OF THIS WORK AND THE WORK Of MI. HIS WITH ALL OTHER ONVISIONS OF WORK. TT IS THIS RESPONSIBILITY TO PROVIDE ALL HIS SUBCONTRACTORS WITH A COMPLETE SET OF BD B. PROVIDE ML 1MTEAALS NO EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE MD OPERAMLE Coo MECH 'CAL SYSTEMS AS MOWED ON THE COMM,ics, AS SPECIFIED. M D AS REQUIRED BY C. INSTALL ALL MECHANICAL EQUIPMENT AND PDPURTDINICES IN ACCORDANCE WTIHI MANUFACTURERS' INSTRUCTION'S. THE CONTRACT DOCUMENTS, MD APPLICANME c00ES ANO REGULATIONS. 0. COORDINATE CONSTRUCHON OF ALL MECHANICAL WORK WITH MCHITEC URAL.. STRUCTURft. OVA.. ELECTING% WORK, ETC., SHOW OR SPECIFIED ON OTHER CONTRACT DOCUMENTS. E. THE =ATKINS OF ALL RDAS SHIOVM ON THE DI MAINaS, THAT ARE NOT DIMENSIONED. ARE APPROOXMIKTE ONLY. THE CtACT LOCATIONS NECESSARY TO SECURE THE BEST COMMONS AND RESULTS Bw1 SE RASED UPON PROJECT SITE COIIDMONS. DO NOT SCALE ORIAMMGS. F. MECHANICAL CONTRACTOR OWL ENSURE THAT ALL EQUUPMDIT, PIPING MD DUCTWORK NOT SOW USED OR SHOWN TO RE IM IS FULLY REMOVED AND NOT MINI LOVED N PUCE R ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED 1O INSTALL THE MECHANIC& SYSTEMS SHAM BY A LANDLORD *PROM ROOFING CONTRACTOR AT MS OONIMICTR7R'S WOOL c omoso E ROOF PEME'TIMTIONS WTTN LANDLORD MD WETEML COSRRMICIOR. N. EEQUIPIADR, IOTAUJITIOTS NO MITETMI S SMALL COMPLY WITH Ail *PUMICE LANDLORD I. THE CONTRACTOR WWI SE REVOINTISLE FOR ALL F. CONNECTIONS TO THE UIKIND'S ME M ROINM SYSTEMS AS /MPPLRCURME. COOR4INITE ALL SYSTEMS IN F.D. E .1. TIE CONTRACTOR SILL SE REIFONIMILE FOR FIELD VERIFYING. PRIOR TO FINAL SID. ALL UMW STUB' - NI, TAPS, ETC. FOR NECHINICOL MIMS MIN 1ENAlIT's wpm K. NO FIERMASI OUICTSOMep ALLOWED. ▪ AML DUCTWORK TO BE NMI. ROUND OUC:T ND N SALES WA °DUNG 10 SE ROUND b'' -al ME DUCT, OR CLEM= SUFFIClIITL.Y N PNMIIHON FOR PINING. M. COOINIMIE ONUAER, 1E5TER. AID C ALE LrOCMIOMS VIM AACNIITECCTU NAL REFLECTED MUM RIMMS, UONANO ATM ow* MUM TIM NO ME NINON OYCT MMOamosno AT: NA /RICE Y'. N. MINCH CURT NUAIMI TO OAPUIBER$ INNCL BE SAME IRE IS OIFFNNEt NECK UNtiEIR !!101111 P. WAD PIPINS EMU BE Man FOR PILL OPEN CEILMO ONFNERER IIlIA1Ti. VERIFY ALL CONDITIONS IN FIELD PRIOR TO BID N ' �D J.T.NAKAOKA ASSOCIATES ARCHITECTS 10390 SANTA MONICA BLVD LOS ANGELES, CALIF. 90025 TELEPHONE: (310)286.9375 THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF ALL PORTIONS OF CONSTRUCTION DOCUMENTS (INCLUDING, BUT NOT LIMITED TO DETAILS, DIMENSIONS, PLANS SECTIONS AND SPECIFICATIONS) PERTAINING TO ANY SPECIFIC AREA OR ITEM OF CONSTRUCTION PRIOR TO COMMENCEMENT OF WORK THE CONTRACTOR SHALL NOTIFY THE ARCHITECT'S OFFICE MIMAEDIATELY OF ANY , DISCREPANCIES OR OMISSIONS PRIOR TO COMMENCEMENT OF ANY WORK AND AWAIT THE ARCHITECTS CLARIFICATION WHERE APPLICABLE. NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF. ARE PROPRIETARY AND CANNOT SE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF THE J.T. NAKAOKA ASSOCIATES ARCHITECTS. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS. GOVERNMENT AGENCIES. VENDORS AND OTHER PERSONNEL ONLY N ACCORDANCE WITH THIS NOTICE. COPYRIGHT ® J.T. NAKAOKA ASSOCIATES ARCHITECTS; 2003 ALL RIGHTS RESERVED. TENANT IMPROVEMENT WESTFIELD SOUTHCENTER 633 SOUTHCENTER SPACE 1568 TUKWILA, WA 90188 W.J. Consultants SUTHERLAND & ASSOCIATES, INC. CONSULTING ENGINEERS 6300 WEST OLD SHAKOPEE ROAD SUITE #140 BLOOMINGTON, MINNESOTA 55438 TEL: (952) 346-4180 STRUCTURAL ENGINEER T.B.D. Approvals: Key Plan: NO. Shoot Tile ,lob No. MOM )00( FOREVER 21 Shut No. DATE 12/10/113 REVISION U. PINMAL ouemrTTAL TO LANDLORD AND WONT PIR:UNM NUMMITFAIL • LANDLORD NV CUNT MECHANICAL PLAN Dais seals O1109103 AS NOTED )0xx M 1.0 BALL VALVE Idl GATE VALVE L'i0 MON * FLOOR CLEAN OUT F.C.O. O ELBOW DOWN PIPE BREAK S TEE DOw1N M FLOOR DRAIN • a MECHANICAL SPECIFICATIONS 15000 - GENERAL PMIOVINO NS 0.01 DEFINITIONS: THE TERMS USTED BELOW ARE DEFINED AS FOL,LO WHEN USED IN DMSION 15 WOAK MD ONLY DIVISION 15 WORK. 1. WORK: LABOR AND MATERIALS Of THE CONTRACTOR AND /OR SUBCONTRACTOR. 2. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DOMINOS. DELVER TO THE JOP LIITE IN NEW CONDITION AND GUARANTEE. 3. INSTALL RECEIVE AT THE JOB-SITE. UNLOAD. STORE. SET W PLACE, CONNECT, PUKE N OPERATION AND OW /ONCE. 4. PROVIDE: FURNISH AND INSTALL. 5. CONNECT: BRING SERVICE TO THE EQUIPMENT AND MIKE FINAL ATTACHMENTS NCLUOINi NECESSARY PIPE FITTINGS. DUCTWORK, I. CONCEALED: . HIDDEN FROM SIGHT N CHASES. FURRED SPACES. SHAFTS ABOVE MK EMBEDDED IN CONSTRUCTION. N CRAWL SPACES 7. EXPOSED: NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. 0.02 PERFORMANCE: MM(cIONICAL CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED, INDICATED MID REQUIRED UNLESS OTHERWISE NOTED. INCLUDING FINAL CONNECTIONS. IN A WORKMMANN.ICE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE TRADE. 0.03 SITE EXAMINATION: DONNE SITE BEFORE BIDDING. CLAIM NO EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDITIONS. IF SITE CONDITIONS REQUIRE MODIFICATION OF THE SYSTEMS INDICATED N THESE DOCUMENTS. SO ADVISE ENGINEER, AND IF ACCEPTED BY ENGINEER, INCLUDE COST OF SUCH MODIFICATIONS IN BID. 0.04 JOBSITE CONDITIONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0.05 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECESSARY FOR A COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.06 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSING. BONDING. AND INSURANCE, AND PERFORM OTHER ADMINISTRATIVE FUNCTIONS. AS REQUIRED. 0.07 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES. 0.08 COORDINATION: CONFORM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HEREIN. REFER ALSO TO STRUCTURAL AND ELECTRICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER TRADES. 0.09 CUTTING AND PATCHING: CUT AND PATCH AS REQUIRED. CUT OR WELD STRUCTURAL. MEMBERS ONLY WITH APPROVAL OF STRUCTURAL ENGINEER. PATCHING SUBJECT TO APPROVAL BY ARCHITECT. 0.10 EXISTING FLOORS: TRENCH OR CORE BORE EXISTING FLOORS PER LANDLORD► 0.11 ROOF PENETRATIONS: COORDINATE WITH LANDLORD. 0.12 EQUIPMENT : REIMBURSE ELECTRICAL CONTRACTOR, AT NO CHARGE TO TENANT. FOR HIS COSTS INCURRED DUE TO SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.13 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT. WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.14 REFERENCE STANDARDS: COMPLY WITH APPLICABLE STANDARDS OF NFPA, ANSI. UL ASHRAE, AND SMACNA. EXCEPT AS SUPERSEDED BY LOCAL AUTHORITY. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED CODE MINIMUM REQUIREMENTS. 0.15 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES, LANDLORD, SERVING UTILfl ES, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD. LOCAL AUTHORITY, AND OTHERS AS REQUIRED. 0.16 MATERIALS AND EQUIPMENT: PROVIDE NEW, UL LISTED. COMMERCIAL GRADE MATERIALS. DEVICES. EQUIPMENT. AND FIXTURES, SUITABLE FOR ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPUMIT WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION. AND APPROVED BY THE ENGINEER. 0.17 SHOP DRAWINGS: BEFORE ORDERING EQUIPMENT AND MATERIALS, SUBMIT NOT LESS THAW FNE CERTIFIED COPIES OF ALL SHOP AND EQUIPMENT DRAWINGS FOR ENGINEER'S REVIEW. WHO WILL RETAIN TWO COPIES. ONLY FURNISH SYSTEMS AND EQUIPMENT IN COMPLWICE WITH ACCEPTED SHOP DRAWINGS. 0.18 INSTALLATION: INSTALL ALL MATERIALS. EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURERS' INSTRUCTIONS. 0.19 LAYOUT: INSTALL ALL PIPING AND DUCTWORK TO PRESENT A NEAT AND ORDERLY APPEARANCE RUN ALL LINES PARALLEL WITH BUILDING CONSTRUCTION. MAINTAIN HEADROOM AND EQUIPMENT CLEARANCE. AND GRADIENT WHERE REQUIRED. ALLOW FOR EXPANSION AND CONTRACTION. 0.20 ACCESS DOORS: PROVIDE ACCESS DOORS OR PANELS FOR ALL VALVES. CLEANOUTS. DAMPERS. CONTROLS. DEVICES. AND OTHER ITEMS REQUIRING INSPECTION OR MAINTENANCE ACCESS PANELS SERVING HVAC COMPONENTS SHALL BE 12- RANCHES BY 12- INCHES MINIMUM OR LARGER TO PROVIDE SUFFICENT WORKING CLEARANCE FOR COMPONENT BEING ACCESSO1 0.21 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT. 0.22 0 & M MANUALS: AN OPERATION AND MNNTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OV TER OR OPERATOR. THE MANUAL SHALL INCLUDE BASIC DATA RELATING TO THE OPERATION AND MWNTDONCE OF HVAC SYSTEMS AND EQUIPMENT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. WHERE APPLICABLE, HVAC CONTROLS INFORMATION SUCH AS DIAGRAMS, SC DAATICS, CONTROL SEQUENCE DESCRIPTIONS. AND MNNTENNANCE AND CALIBRATION INFORMATON SHALL BE INCLUDED. 0.23 WARRANTY: UNCONDMONALLY WARRANT NJ. WORK TO BE FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF FINAL ACCEPTANCE, EXCEPT WARRANT AIR CONDITONING COMPRESSORS FOR FIVE YEARS. DURING WARRANTY PERIOD, REPAIR OR REPLACE DEFECTIVE MATERIALS. EQUIPMENT OR WORKMANSHIP WITHOUT COST TO TENANT. 0.24 EQUIPMENT IDENTIFICATION: IDENTIFY NJ. APPLICABLE ROOFTOP EQUIPMENT WITH TENANT'S NAME AND SPACE NUMBER. USING r PAINTED CHARACTERS OR STAMPED METAL TAG. 0.25 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT, PPE AND DUCT LOCATIONS TO AVOID CONFUCTS WITH OTHER CONSTRUCTION AND TRADES. 0.26 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE THESE SPECIFICATIONS. 0.27 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS MID REQUIREMENTS. 0.28 PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS INCLUDED IN THESE SPECIFICATIONS MAY BE REQUIRED FOR THIS PROJECT. 0.29 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ERRORS, DISCREPANCIES OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FACING SUCH NOTICE, BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO MI MI; ARCHITECT OR ENGINEER. 15100 - PIPE MD FITTINGS 1.10 PIPE HANGERS NG SUPPORTS: PROPERLY SUPPORT ALL PIPING FROM JOISTS (TOP CHORD) OR OTHER STRUCTURAL MEMBERS. FOR PIPES UP TO 4 O.D no. 260 CLEWS HANGERS WITH 3/8" ROD, OR FIG. 195 BRACKETS. 1.20 INSULATION SHIELDS: PROVIDE 18 GAUGE X 12" LONG GALVANIZED INSULATION SHIELDS AT SUPPORT POINTS FOR INSULATED PIPES. 1.30 PPE SUPPORT SPACING: SUPPORT PIPE NOT LESS THAN S FT. ON CENTER FOR COPPER PIPE UP TO 2' 0.0., OR NOT LESS THAN 10 FT. ON CENTER FOR STEEL PPE UP TO 4" 0.0. 1.40 COPPER CONTACT: PROVIDE COPPER PLATED MANGERS ND SUPPORTS WHERE N CONTACT WITH COPPER PPE. 1.50 PPE SLEEVES: SLEEVE ALL HORIZONTAL PIPING WHICH PENETRATES WALLS WITH STANDIMD WEIGHT STEEL. PIPE OF 1" GREATER DIAMETER DWI PIPE OR INSULATION 0.0. CUT SLEEVE FLUSH WITH IOU. MINH BOTH 1.00 SERI. ANT: SEAL PIPE SLIMS WITH ROPE AND LXPANDO NON- OMIROIt SEALANT. FIRE/SMOKE SEAL PENETRATIONS Of RATED CONSTRUCTION TO MAN A N RATING. 1.70 WALL PLATES: FIT UNCOVERED PIPE PASSWO THROUGH WALLS WITH WALL PLATES. CRANE NO. 10 OR EQUAL 15200 - THERMMAI. AND ACOUSTIC INSULATION 2.10 VIBRATION ISOLATION: PROVIDE EFFECTIVE VIBRATION ISOLATION PI FOR MOVING T� T HE INCITE HANDBOOK. HVAC APPLICATIONS (LATEST EDITION). CHAPTER 'SOUND MD VIBRATION CONTROL'. 2.20 NOISE TRANSMISSION: INSTALL PIPING AND DUCTWORK FREE FROM CONTACT WITH STRUCTURE OR EQUIPMENT TO PREVENT NOISE TRANSMISSION. 2.30 INSULATION REQUIREMENTS: INSULATE SYSTEMS AS SPECIFIED ONLY AFTER THEY HAVE SEEN TESTED AND INSPECTED. CLEAN ALL SURFACES THOROUGHLY OF MOISTURE, FOREIGN MMATERAL. GREASE. AND RUST. INSTALL INSULATION CONTINUOUS THROUGH POWWOWS. 2.31 INSULATION HAZARDS: USE ONLY INSULATION ADHESIVES, SEALERS, AND CWTINOS WITH FIRE HAZARD RATING NOT TO EXCEED 29/50/50 FLAME SPREAD, FUEL CONTRIBUTED. AND SMOKE DEVELOPED. IN WITH UL 723 AND ASTM E84. 2.32 INSULATED PLUMBING SYSTEMS: INSULATE HOT AND COLD WATER PIPING. AND HORIZONTAL WASTE PIPING IN CEILNG SPACE. WITH 1 - E THICK CURED CELL. SELF SEALING FLEXIBLE TUBING, ARNAFLEX 2000 OR 2.33 INSULATED NM PIPING SYSTEMS: INSULATE REFRIGERANT SUCTION PIPING AND COOLING COIL CONDENSATE PIPING WITH 3/4 -W. THICK CLOSED CELL FOAM INSULATION, RUBATEX OR EQUJAL. 2.34 ACOUSTICALLY LINED SUPPLY AND RETURN DUCT: UNLESS OTHERWISE INDICATED ON THE PLANS, LINE SUPPLY AND RETURN DUCTWORK WITHIN 10 -FEET OF THE DISCHARGE AND INTAKE OF MR HANDLING UNITS WITH 1" THICK GLASS FIBER ACOUSTICAL DUCT LINER BOARD, OMENS- CORNING, OR EQUAL. INCREASE DUCT SIZE INDICATED ON PLANS 2' EACH DIMENSION TO ACCOMMODATE DUCT LINER. MATERIALS SHALL HAVE A MOLD -, HUMIDITY -, AND CORROSION-RESISTANT SURFACE THAT MEETS THE REQUIREMENTS OF UL 181. 2.35 EXTERNALLY INSULATED SUPPLY DUCT: INSULATE SHEET METAL DUCTWORK WITH 1 AND 1/2 -INCH FIBERGLASS BLANKET DUCT WRAP WITH AN INTEGRAL VAPOR BARRIER FACING, OVENS- CORNING, OR EQUAL THE THERMAL RE STAN 1 CE DO NOT INSULATE ' IONS OF DUCTWORK WHICH ARE INTERNALLY LINED. DO NOT INSULATE SUPPLY AIR DUCTWORK IN CONOTTIONED SPACES UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 2.36 INSULATED EXHAUST AND OUTSIDE MR DUCT: EXTERNALLY INSULATE WITH 2" THICK GLASS FIBER INSULATION WITH KRAFT FOIL VAPOR BARRIER, OWENS- CORNING, OR EQUAL 2.40 INSULATED FLEXIBLE DUC T: GENERAL ENVIRONMENTAL CORPORATION TYPE G30A OR EQUAL. 5'-0" MAXIMUM LENGTH WITH A MINIMUM ELBOW RADIUS OF 1.5 X D AND A THERMAL RESISTANCE. USE ONLY IN FOR FINAL CONNECTIONS TO CEIUN G DIFFUSERS. 15300 - FIRE PROTECTION 3.10 WORK INCLUDED: PROVIDE ENGINEERED DESIGN UNLESS OTHERWISE REQUIRED BY THE LANDLORD OR THE AUTHORITY HAVING JURISDICTION. FURNISH, FABRICATE AND INSTALL ALL MATERIALS, AND SECURE ALL NECESSARY APPROVALS FOR MODIFICATIONS TO THE DAIS LNG FIRE PROTECTION SYSTEM THROUGHOUT THE ENTIRE SPACE. 15400 - PLUMBING 4.10 DOMESTIC ( POTABLE) WATER SUPPLY PIPING: ABOVE GROUND: TYPE L HARD TEMPER COPPER TUBE PER ASTM B88, WITH WROUGHT COPPER FITTINGS PER USASI B16.18 AND .18A. BELOW GROUND: TYPE K SOFT TEMPER COPPER TUBE. USE ONLY 95/5 LEAD -FREE SOLDER IN POTABLE WATER PIPING. PROVIDE DIELECTRIC UNIONS AT EVERY JUNCTION OF TWO DISSIMILAR METAL PIPE MATERIALS. 4.20 DRAIN. WASTE AND VENT PIPING: ABOVE GRADE: NO-HUB CAST IRON SANITARY 301 -69T OR SCREWED GALVANIZED PIPE WITH FITTINGS. BELOW GRADE: NO-HUB CAST IRON SANITARY 301 -89T OR SERVICE WEIGHT CAST IRON HUB GASKET, PER CISPI HSN -68T. SYSTEM PER CISPI CAST IRON DRAINAGE SYSTEM PER CSPI AND SPIGOT MATH NEOPRENE 4.40 VALVES: FURNISH AND INSTALL VALVES WHERE INDICATED ON PLAN AND AS NECESSARY FOR PROPER SYSTDA OPERATION AND COMPONENT ISOLATION. PROVIDE VALVES RATED FOR 125 PSI OR GREATER WORKING PRESSURE IN WATER PIPING. CHECK VALVE UP TO 3" CRANE NO. 37, OR EQUAL GLOBE VALVE UP TO 3" CRANE NO. 1, 17W, OR EQUAL GATE VALVE UP TO 3" CRANE NO. 428, 1334. OR EQUAL BALL VALVE UP TO 3" APOLLO SERIES 70 -100. 70 -200, OR EQUAL TEMP. & PRESS. RELIEF VALVE WATTS 10L MODEL M7, OR EQUAL, 3/4"M X 3/4" F SHOCKSTOP WADE W -5 (HOT), WADE W -10 (COLD) BACKFLOW PREVENTER WATTS NO. 98D. OR EQUAL VACUUM RELEF VALVE WATTS NO. N36 - 3/4 ". OR EQUAL PRESSURE REDUCING VALVE WATTS NO. U5 SERIES 4.70 PLUMBING FUTURES: FURNISH AND INSTALL COMPLETE WITH FITTINGS AND ACCESSORIES AS REQUIRED 4.81 INSTANTANEOUS WATER HEATER: CHRONOMITE LABS, INC.. MODEL S -30L. OR APPROVED EQUAL,. UL LISTED, WITH CAST ALUMINUM CASING, PLASTIC ELEMENT ASSEMBLY WITH STAINLESS STEEL PARTS, AND 1/4" NPT FEMALE FITTINGS. HEATER ENERGIZES AT 0.4 GPM, DE-ENERGIZES AT 0.3 GPM, WITH CAPACITY TO HEAT 0.5 GPM TO 40'F TEMPERATURE RISE. THE UNIT SHALL BE RATED FOR 150 PSG MAXIMUM OPERATING PRESSURE AND 190 DEGREES F MAXIMUM OPERATING TEMPERATURE. 4.95 CLEANING MID TESTING: CLEAN. DISINFECT, AND TEST ALL PLUMBING AND PIPING SYSTEMS. 15500 - HVAC PIPING AND SPECIALTIES 5.25 MISCELLANEOUS DRAIN LINES. RECEIVING COOUNG COIL CONDENSATE, DRIP FOR HUMIDIFIERS, ETC.: PIPING - PIPING SHALL BE TYPE "DVV" COPPER. FITTINGS - FITTINGS SHALL BE WROUGHT COPPER, SOLDER JOINTS. JOINTS - JOINTS SHALL BE 50-50 SOLDER AND #50 FLUX. 15700 - AIR HMNNDUNG AND VENTILATION 7.10 PACKAGED AIR MANDUNG UNIT: CARRIER, TRAHNE, YORK, MCQU LAY, LENNOX,DRAW- THIRD, FOR HORIZONTAL INSTALLATION. UNIT SHALL BE DESIGNED AND TESTED IN ACCORDANCE WITH ASHRAE 15 SAFETY CODE FOR MECHANICAL. . REFRIGERATION. LATEST EDITION AND SHALL BE ETL AND ETLC LABELED. UNIT INSULATION SHALL COMPLY WITH NFPA 90A REQUIREMENTS FOR FLAME SPREAD AND SMOKE GENERATION. DIRECT EXPANSION AND CHILLED WATER COILS SHALL BE BURST TESTED AT 435 PSI AND LEAK TESTED AT 150 PSI. UNIT SHALL CONSIST OF . BELT -DRIVEN CENTRIFUGAL FAN(S), MOTOR AND DRIVE ASSEMBLY, PREWRED FAN MOTOR CONTACTOR, FACTORY- INSTALLED REFRIGERANT METERING DEVICES (DX COIL). COOUNG COIL 2 -IN. DISPOSABLE AIR FILTERS AND PVC CONDENSATE ORAN PANS. CABINET SHALL BE MIL-GALVANIZED STEEL. WITH PANELS FULLY INSULATED WITH 1/2 N. FIRE RETARDANT MATERIAL CONTAINING EPA - REGISTERED IrIMOBMUZED ANTIMICROSAAL AGENT. COOLING COILS: COILS SHALL BE 4-ROW WITH COPPER TUBES MD ALUMINUM PLATE FNS. DX COILS SHALL HAVE FACTORY-INSTALLED THERMOSTATIC EXPANSION NAIVES CAPABLE OF EXTERNAL ADJUSTMENT. HEATING COILS, ELECTRIC: COILS SHALL BE FACTORY- SUPPLIED FOR FIELD INSTALLATION; SHALL BE ETL AND ETL: APPROVED AND SHALL HAVE SINGLE-POINT POWER WIRING. HEATER ASSEMBLY SHALL INCLUDE CONTACTORS WITH 24 -VOLT COILS, POWER WIRING, 24 VOLT CONTROL WIRING TERMINAL BLOCKS, MD A HANGED ACCESS PANEL. 7.30 CONDENSING UNIT, Mt- COOLED (CU): CARRIER, TRANIE YORK, MCQUAY OR LENNOX; NO EXCEPTIONS. UNIT SHALL BE RATED IN ACCCM NICE WITH ARI STANDARD 210/240 MD 270 OR 360. UNIT CONSTRUCTION SIW,L COMPLY WITH ANSI /A 11API MD NEC. CONDENSER COILS FOR HERMETIC COMPRESSOR UNITS SMALL BE LL* TESTED AT 200 PSG MD PRESSURE TESTED AT 428 PSG. COILS SMALL SE CONSTRUCTED OF ALUMNUJMI FINS MECWIMCIM.LY BONDED TO COPPER TUBES. REFRIGERATION CIRCUIT COMPONENTS SMALL INCLUDE HOT OAS MUFFLER, 1110H-SIDE PRESSURE RELIEF DEVICE, MUM LNNE SHUTOFF VALVE, SUCTION MD DISGHMIROE SHUTOFF VALVE'S, HOLDING CHARGE OF R -22 AID COMPRESSOR OIL MINIMUM CONTROLS SOU. . INCLUDE FINE MINUTE COMPRESSOR SNORT -C VLDIO PROTECTION, SUCTION CUTOFF WIL ER COMPRESSIOR CAPACITY CONTROL LOW MiAENIT CONTROL IMTIOWEIIC NET ( AFTER IRE'ETTIIO AT 1HE TIAT'), I WRIT. MINI! AT MT. 16000 - DUCTWORK AND APPURTENANCES S.10 SHEET METAL DUCTWORK: A. FABRICATE AND INSTALL AS RECOMMENDED IN LATEST EDITIONS OF SMACNA HVAC DUCT CONSTRUCTION STAINDMDS- -METAL AND FLEXIBLE MD THE MOW GUIDE AND DATA BOOK FOR SHEET METAL DUCTWORK WAWA SUPPLY, RETURN AND EXHAUST SYSTEMS OPERATING SEMEN -2.0 IN.-W.O. AND +2.0 IN. -W.O. MA OMUM PRESSURE. INSTALL WHERE INDICATED ON THE PLANS. DUCT SIZES SHOWN ON THE DRAWINGS ME NOMINAL INSIDE CLEAR DIMENSIONS. WHERE INTER/ AL INSULATION IS PROVIDED, DUCT SIZES MUST BE INCREASED APPROPRIATELY TO MAINTAIN THE INDICATED DIVISIONS. ASSEMBLE AND INSTALL DUCTWORK W ACCORDANCE WITH RECOONIZED INDUSTRY PRACTICE FOR ACHIEVING MR TIGHT (811 LEAKAGE) AND NOISELESS (NO OBJECTIONABLE SYSTEMS. CAPABLE OF PERFORMING EACH INDICATED SERVICE. ALL REQUIRED DAMPER& CONNECTIONS TO AIR TERMINALS. AND OTHIERt ocassonas NECESSARY FOR A COMPLETE OPERATING SYSTEM. S . FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ANSI /ASTM A 527, LOCKFORMlNG QUALITY, WITH 1N SI /ASTM A - 526 000 ZINC COATING; MILL PHOSPHATIZED FOR EXPOSED LOCATIONS. MINIMUM SHEET THICKNESS MD REINFORCING SWILL BE AS FOLLOWS: DUCTS UP 10 12' WIDEST DIMENSION OR DIAMETER: 28 GAUGE. DUCTS 13" TO 24" WIDEST DIMENSION: 24 QAUE. DUCTS 25' TO 42" WIDEST DIMENSION: 22 OA00E. DUCTS 43" TO 114' WIDEST DIMENSION: 20 GAUGE. C. DUCT SEALANT: UNITED DUCT SEALER, OR EQUAL. D. SUPPORT MATERIALS: EXCEPT AS OTHERWISE INDICATED. PROVIDE HOT- DIPPED GALVANIZED STEEL FASTENERS, ANCHORS, RODS STRAPS, TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. E. ANY SUPPLY DUCTWORK AND PIDIUIIS THAT ARE DESIGNED TO OPERATE AT STATIC PRESSURE FROM 0.25 INCHES TO 2 INCHES WATER COLUMN INCLUSIVE WHICH ME LOCATED OUTSIDE OF THE CONDITIONED SPACE OR IN RETURN PLENUMS SHALL HAVE JOINTS SEALED IN ACCORDANCE WITH SEAL CLASS C AS DEFINED IN THE SAWCNA HVAC DUCT LEAKAGE TEST MANUAL PRESSURE SENSITIVE TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT WHERE SUCH DUCTS ARE DESIGNED TO OPERATE AT STATIC PRESSURES OF 1 INCH WATER COLUMN OR GREATER. 8.20 DUCTWORK ACCESSORIES: �y ��UVERS p� A. BALANCING DAMPERS: MR BALANCE. INC., LO & DAMPERS. INC., RUSKIN OR EQUAL. PRCMDE MANUAL SINGLE OR MULTIBLADE DAMPERS, AS INDICATED AND AS CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS. B. DAMPERS SHALL HAVE RIGID 2 -14. X 1/2-IN. X 10 GAUGE CHANNEL FRAMES, BALL OR BRONZE SLEEVE BEARINGS, 1/2 -IN. POLISHED STEEL. AXLES, 16-- GAUGE, REINFORCED. FELT -EDGED BLADES (NOT OVER 8-IN. WIDE) THE ENTIRE PERIMETER. VOUNE DAMPERS DUCTS LARGER THAN 12 IN. X 6 IN. SHALL BE 7HE OPPOSED BLADE TYPE. DAMPERS IN ROUND DUCTS AND DUCTS 12 -IN. X 6-N. AND SMALLER SHALL BE BUTTERFLY TYPE. ROUND BUTTERFLY TYPE VOLUME DAMPERS SHALL BE 30 GAUGE, GALVANIZED STEEL THROUGH 12 -IN. DIAMETER; 28 GAUGE FOR ABOVE 12 -IN. C. ALL DAMPERS SHALL BE EQUIPPED WITH STANDARD QUADRANTS OF SUITABLE SIZE N EQUIPMENT ROOMS /AREAS AND YOUNG .301A, OR EQUAL, RECESSED-TYPE IN FINISHED AREAS. PROVIDE QUADRANT LOCKING DEVICE FOR EACH DAMPER ON ONE END OF THE SHAFT AND AN END BEARING PLATE ON THE OTHER END FOR DAMPER LENGTHS OVER 12 -IN. PROVIDE EXTENDED QUADRANT LOCKS AND EXTENDED BEARING PLATES FOR EXTERNALLY INSULATED DUCTWORK. APPROVED MANUFACTURERS ARE VENTFABRICS, MD YOUNG REGULATOR CO. D. DAMPERS SHALL BE COATED WITH RED ZINC CHROMATE PRIMER OVER A BOND COAT. E. VOLUME DAMPERS, SPLATTERS AND DEFLECTORS SHALL BE PROVIDED IN ALL DUCTS TO PERMIT ACCURATE BALANCING OF THE SYSTEM. THE DAMPERS. SPUTTERS MID DEFLECTORS SHALL BE ADJUSTED TO SATISFY THE HEATING AND VENTILATING REQUIREMENTS OF THE CON Om NED SPACE AND LOCKED N PLACE 8.40 AIR OUTLETS AND INLETS: FURNISH AND INSTALL. TITUS, KRUEGER. OR APPROVED EQUAL.. AS SCHEDULED. OPPOSED BLADE VOLUME DAMPERS FOR REGISTERS SHALL BE TITUS SERIES AG-35, KRUEGER SERIES OBC, OR EQUAL, OPPOSED BLADE TYPES WITH VERTICAL BLADES AND SCREWDRIVER SLOTS OR ALLEN WRENCH ADJUSTMENT ACCESSIBLE THROUGH THE REGISTER. IT SHALL BE THE CONTRACTOR'S RESPONSIBIL I Y TO PROVIDE MISCELLANEOUS ITEMS AS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPES OF WALLS AND CEILNGS USED ON THE PROJECT. THIS SHALL INCLUDE SUCH ITEMS AS FASTENERS. PLASTER RINGS, SUPPORTS, ETC. 8.60 FLDCIBLE CONNECTIONS: VENTFABRICS, INC.. DURO DYNE, OR EQUAL PROVIDE FLEXIBLE DUCT CONNECTIONS WHEREVER DUCTWORK CONNECTS TO VIBRATION ISOLATED EQUIPMENT AND WHERE SHOWN OR NOTED. MAKE AIR -TIGHT JOINTS. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR THERMAL. MA L. TRANSVERSE AND TORSIONAL. MOVEMENT. 8.80 DUCT SMOKE DETECTOR: FURNISH AND INSTALL INNOVAIR MODEL 1DH1OOAACDCLP PHOTO ELECTRIC TYPE DUCT SMOKE DETECTOR WITH 24 VAC OPERATION, OR APPROVED EQUAL. IN SUPPLY DUCT AND /OR RETURN DUCT AS INDICATED. CONNECT TO HVAC CONTROL SYSTEM FOR POWER AND TO DE--E FAN UPON SMOKE DETECTION. CONNECTION TO REMOTE TEST STATION (F INDICATED) SHALL BE BY THIS CONTRACTOR. 8.81 REMOTE TEST STATION: FURNISH AND INSTALL MINIOVAIR KEYED REMOTE TEST STATION WITH LED INDICATORS, OR APPROVED EQUAL IN APPROVED LOCATION. STATION SHALL INCLUDE A KEY -ACTIVATED TEST AND RESET' FUNCTION. STATION ALSO SHALL. PROVIDE VISUAL MONITORING USING GREEN (POWER). AMBER (TROUBLE), AND RED (ALARM) LED LIGHTS. VERIFY EXACT APPROVM LOCATION WITH LOCAL CODE INSPECTOR PRIOR TO INSTALLATION. ALL ASSOCIATED HARING, M. SHALL BE PROVIDED BY THIS 15900 - SYSTEM CONTROL AND OPERATION 9.10 SPACE TEMPERATURE CONTROL FURNISH AND INSTALL UNLESS NOTED OTHERWISE. ALL THERMOSTATS, SENSORS, CONTROLLERS, RELAYS. CONTACTORS, DAMPERS, ACTUATORS, TUBING. CONTROL WIRING AND ALL OTHER ITEMS AND MATERIALS NECESSARY FOR A COMPLETE AND PROPERLY OPERATING TEMPERATURE CONTROL SY5TEMM AS SPECIFIED BELOW. ALL THERMOSTATS MD OTHER CONTROL COMPONENTS SHALL BE HONEYWELL, OR APPROVED EQUAL. UNLESS SPECIFIED OTHERWISE. ALL CONITROL WIRING SHALL BE BY MECHANICAL CONTRACTOR AND SHALL BE INSTALLED IN CONDUIT. 9.11 THERMOSTAT: REFER TO "HVAC CONTROLS" ON SHEET M1.0. 9.20 SEQUENCE OF CONTROLS: REFER TO "HVAC CONTROLS' ON SHEET M2.0. 15950 - TESTING. (ADJUSTING. SAO/ICING 9.51 NEBB, AMC, OR TABS CERTIFIED TESTING AND BALANCING CONTRACTOR SHALL BE RESPONSIBLE FOR THE TESTING AND BALANCING OF EVERY HEATING, VENTILATING AND AIR CONDITIONING SYSTEM. THE PERSON OR AGENCY RESPONSELE FOR BALWCIVG OF ME SYST AS SHALL DOCUMENT N WRITING THE AMOUNT OF OUTDOOR AR BEING PROVIDED AND DISTRIBUTED FOR THE BUILDING OCCUPANTS AND ANY OTHER SPECIALTY VENTILATION. TWO (2) COPES OF A WRITTEN REPORT IN NEW, MSC. OR TABS FORMAT SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. 9.52 AIR SYSTEMS SMMLL BE BALANCED N A MANNER TO MINIMIZE LOSSES FROM DAMPER THROTTLING BY FIRST ADJUSTING FAN SPEED THEN ADJUSTING DAMPERS TO MEET DESIGN FLOW CONDITIONS. DAMPER THROTTLING ALONE MAY BE USED FOR AIR SYSTEM BALANCING WITH FM MOTORS OF 1 HP OR LESS, OR F THROTTLING RESULTS IN NO GREATER TWIN 1/3 HP FM HORSEPOWER DRAW ABOVE THAT REQUIRED F THE FM SPEED WERE ADJUSTED. 9.53 HVAC CONTROL SYSTEMS SHILL BE TESTED TO ASSURE THAT CONTROL ELEMENTS ME GYJBRATED, ADJUSTED, MD IN PROPER WORKING CONDITION. F.C.O. `1- 1 -1/2" io - V.T.R. i kr WASTE & VENT RISER • O 4 F NOM H it 0 1 2 4 N.T.S. F.C.O. PLUMBING KEY NOTES Q 1. WEND MD CONNECT 4" UNDERFLOOR SWAM TO LANDLORD'S MINIMUM 4" UNDERFLOOR SANITARY. VERFY LOCATION MD INVERT N FIELD. 2- EXTEND AND CONNECT 2" VENT TO MINIMUM 4" VENT THROUGH ROOF. VERFY ROOF PENETRATION NTH LANDLORD'S FIELD REPRESENTATIVE REUSE EXISTING VENT THROUGH ROOF PENETRATION F POSSIBLE. 3. EXTDD MD CONNECT 3/4" COLD WATER TO LANDLORD'S IMAM 3/4" COLD MATER CONNECTION. PROVIDE ISOLATION VALVE AT EACH FUTURE AND AT POINT OF CONNECTION TO LANDLORD'S COLD WATER MAIN. VERIFY LOCATION AND ROWING TO MN CON N FELD. REUSE EXISTING CONAECTION POINT F 4. INSTANTANEOUS WATER HEATER INSTALL BELOW LAW SD AS NOT TO IMPEDE ON HANDICAP ACCESSIENUTY. 5. FLOOR DRAIN WITH DEEP SEAL TRAP FLIED WITH MINERAL OIL. PLUMBING PLAN ELECTRIC WATER HEATER SCHEDULE M2o M S FEET <> 3 /4" •"' 3 / 4 " 1/4' - 1' -0" i Era I WATER RISER N.T.S. N.T.S. SYMBOL. LEGEND LINETYPE LEGEND DOMESTIC COLD WATER DOMESTIC HOT WATER SWUM SEWER ('ABOVE FLOOR /GRADE) SANITARY SEWER (111110 FLOOR/GRADE) VENT i VERIFY ALL CONDITIONS IN FIELD WITH LANDLORD'S SWORE RAINING FIELD REPRESENTATIVE 1 PLUMBING NOTES A. ALL EUUFI DIT. I1.4TALLAT1ON MD IMTERIALS SMALL COMPLY WITH ALL APPUCAIILE LANDLORD CRITERIA. B . TIE CONTRACTOR SMALL BE RESPONSIBLE FOR FEW VERFYING, PRIOR TO FINAL BID, ALL EXISTING STUB -MIS, TIPS, ETC. FOR PLUMBING SYSTEMS NTNiI TENANT SPACE. C. 11E CONTRACTOR EHALL BE RESPONSIBLE FOR ALL FUNAL CONNECTIONS TO THE LANDLORD'S SASE SYMTEIIMSL COORRDI TOE ALL SYSTEMS N FIELD. D. REMM Ni. EXISTING PLUMBI FOGUIRES, PIPING SYSTEMS, ETC... NOT BONG REUSED... DO NOT JUST NIANDON. • • J.T.NAKAOKA ASSOCIATES ARCHITECTS 10390 SANTA MONICA BLVD LOS ANGELES, CALIF. 90025 TELEPHONE: (310) 286 -9375 THE CONTRACTOR IS RESPONSIBLE FOR (REVIEW OF ALL PORTIONS OF CONSTRUCTION DOCUMENTS (INCLUDING, BUT NOT LIMITED TO DETAILS, DIMENSIONS, PLANS SECTIONS MID SPECIFICATIONS) PERTAINING TO ANY SPECIFIC AREA OR ITEM OF CONSTRUCTION PRIOR TO COMAMENC.EMENT OF WORK THE CONTRACTOR SHALL NOTIFY THE ARCHITECT'S OFFICE IMMEDIATELY OF ANY INCONSISTENCIES, DISCREPANCIES OR OMISSIONS PRIOR TO COMMENCEMENT OF ANY WORK AND AWAIT THE ARCHITECT'S CLARIFICATION WHERE APPLLI CMLE. NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF THE J.T. NAKAOKA ASSOCIATES ARCHITECTS. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY NN ACCORDANCE WITH THIS NOTICE. COPYRIGHT C J.T. NAKAOKA ASSOCIATES ARCHITECTS: 2003 ALL RIGHTS RESERVED. FOREVER 21 TENANT IMPROVEMENT WESTFIELD SOUTHCENTER 633 SOUTHCENTER SPACE #568 TUKWILA►, WA 98188 W.J. Consultants SUTHERLAND & ASSOCIATES, INC. CONSULTING ENGINEERS 6300 WEST OLD SHAKOPEE ROAD SUITE #140 BLOOMINGTON, MINNESOTA 55438 TEL: (952) 346-4180 STRUCTURAL ENGINEER T.B.D. Key Plan: NO. DATE Sheet Ilia REVISION ,ION 2 7 200 LL FINAL SUBMITTAL TO LiANOL ORI7 NO weer 12/10/x3 MUM SLJBI . LANDLORD -- U CUNT PLUMBING PLAN AND MECHANICAL SPECIFICATION Job No. 888• CRW Street No. DIM Score 01/01M3 AS NOTED M2.0 FDH • Is