Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M04-067 - JACK IN THE BOX
JACK IN THE BOX 3742 SOUTH 744T" STREET M04 -067 001 N o U W! • H • W }} g ti<. Nom; UJ, . 1-0 Z H;. LLI • U 0: • • O H' WW ZE F= �i !. •Z Parcel No.: 1523049295 Permit Number: M04 -067 ; z z Address: 3742 S 144 ST TUKW Issue Date: 05/03/2004 w re 2 Suite No: Permit Expires On: 10/30/2004 ui v UO u) o W W J N LL w Owner: g 5 Name: LARRY'S MARKET Phone: u) 3 Address: 11410 NE 124TH ST PMB 626, KIRKLAND WA d w Contact Person: z � Name: MIKE D. SCHEFFLER Phone: 425 922 -9198 Z O - Address: 11021 128 PL NE, KIRKLAND WA Contractor: 8 � _ Name: METRO AIR INC Phone: 425 889 -8224 0 I- Address: 11021 128 PL NE, KIRKLAND, WA = W Contractor License No: METROAI995RC Expiration Date:12 /03/2005 H u_ O . . W Z U = : 0~ Tenant: Name: Address: DESCRIPTION OF WORK: INSTALLING 2 ROOF TOP UNITS, 1 MAKE -UP AIR, HANG 2 EXHAUST GRILLS. ALL DUCT WORK AND DIFFUSERS. Value of Construction: $30,000.00 Fees Collected: $87.00 Type of.Fire Protection: SPRINKLERS Uniform Mechnical Code Edition: 1997 Permit Center Authorized Signature: _,Jd I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name. doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 JACK IN THE BOX 3742 S 144 ST, TUKWILA WA MECHANICAL PERMIT This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M04-067 Date: ` 3 dy Dater - 3 , 01/4 Printed: 05 -03 -2004 z Parcel No.: 1523049295 Address: 3742 S 144 ST TUKW Suite No: Tenant: JACK IN THE BOX doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 7: Manufacturers installation instructions required on site for the building inspectors review. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 10: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 12: Local U.L. central station supervision is required. (City Ordinance #1900) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 14: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 15: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and M04 -067 Permit Number: M04 -067 Status: ISSUED Applied Date: 04/26/2004 Issue Date: 05/03/2004 Printed: 05 -03 -2004 %+,�:..;;twy:+::r.:ziv.. City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) 16: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 17: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 18: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: ` Date: S Print Name: •�S� ��n doc: Conditions M04 -067 Printed: 05 -03 -2004 SITEt LOCATI CITY OF TUKWIIA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: \ -\ 7■K\,\,.3 �Q Tenant Name: \ R 0 7� Building Permit No. • Mechanical Permit No. Works Permit. No. Project No. (Forofce use only). • King Co Assessor's Tax No.: AS ?a p,S� Suite Number: Floor: New Tenant: .... Yes ..No Property Owners Name: Mailing Address: City E -Mail Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: ,applications \permit application (3 -2003) 3/2003 Page 1 State Zip °-,CONTACT::PERSO NameS�',1L for, Day Telephone -> —��� —c) Mailing Address: \t \ 4) V 1 City State Zip E -Mail Address: �0 .� \� ca \SL.0 \17 na t�l Fax Number:: — AcP, FRAU CONTRACTOR.INFORMATION Company Name:rrl0 c cyn Mailing Address: n , O ) Ox � or City State Zip Contact Person: Day Telephone: S3 — 8 s3 — L l')Qc Fax Number: S3 8S 3- ` 0$ Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** CHITECT OF RECORD l Al plan be, wet s by Archite of Record.' Company Name: Mailing Address: City Day Telephone: Fax Number: State State Zip ENGINEER RECORD All plans, must be wet stamped by Engineerof Record ' Company Name: Mailing Address: Zip City Day Telephone: Fax Number: BUILDING PERMIT INFORW TION- 206 =431 -3670 Valuation of Project (contractor's bid price): $ , ?Q C) O iJ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes 0.. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below 1" Floor 2 "a Floor 3f Floor Floors Basement • Accessory Structure'!': , Attached Garage Detached Garage': Attached Carport Detached Carport:: Covered Deck Uncovered Deck ', Existing Interior • Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes 0 ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0.. Sprinklers ❑ ..Automatic Fire Alarm (]..None . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ .. No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. lapplications\permit application (3.2003) 3/2003 Page 2 Existing Building Valuation: $ I PUBLIC WORKS PERMIT INF TION :206 -433 017 Scope of Work (please provide detailed information): ❑ ...Total Cut ❑ ...Total Fill \applications \pennit application (3.2003) 3/2003 Call before you Dig: 1- 800 - 424 -5555 Please refer, to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #125 ❑ ...Water Availability Provided Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public _ ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line WO# WO# WO# Private Private ❑ .. Highline ❑ .. Work in Flood Zone ❑ .. Storm Drainage Page 3 ❑ ...Renton Sewer District ❑ ...Tukwila ❑... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ... Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ... Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) Day Telephone: City State Zip Day Telephone: City State Zip Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU • Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 3 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System 30 -50 I-IP /1,750,000 BTU Appliance Vent Hood ;] 50+ HP /1,750,000 BTU Heat/Refrig /Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind rThi `MECHANICAL PERMIT :INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name:M Ei aG \C (- Mailing Address: \ \O\ \a� (i) • Contact Person:M ' k-- SC\.1`trt �r E -Mail Address:c C 6P Q uQs•t -ot..) cve‘ Indicate type of mechanical work being installed and the quantity below: k (*\t\co 0 \-,) �.1 ' S ' City State Zip Day Telephoneya5 _C- , ` \ Fax Number: -'\ -tea -3 D g Contractor Registration Number: (' _ Q z f=a T c C' . \ S 6Z L_ Expiration Date: - * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ ©) M4 Scope of Work (please provide detailed information): `1• N c1 Use: Residential: New ... Replacement .... D Commercial: New ....El Replacement .... 0 Fuel Type: Electric Ej Gas.... Other: LICATION NOTES Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant fora period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED TI-IIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signa ur Print Nam -C:-. �1 Mailing Address (\ tapplicationstpermit application (3.2003) 3/2003 Page 4 Day Telephone City State Zip Date Application Accepted: 4-6.24 ,-,9(( Date Application Expires: /D 0e( Staff Initials: i Parcel No.: 1523049295 Address: 3742 S 144 ST TUKW Suite No: Applicant: JACK IN THE BOX Payee: METRO AIR INC. ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 1677 87.00 Account Code Current Pmts 000/322.100 69.60 000/345.830 17.40 Permit Number: M04 -067 Status: APPROVED Applied Date: 04/26/2004 Issue Date: Receipt No.: R04 -00527 Payment Amount: 87.00 Initials: SKS Payment Date: 05/03/2004 01:34 PM User ID: 1165 Balance: $0.00 Total: 87.00 0521 Q5/04 1710 TOTAL B7.00 Printed: 05 -03 -2004 Project: n i49 .4- -- 1i- �C3 Type of Inspection: 1 >7Gi ,e Date Called Address: 79? &) 1/ Special Instrucciions: Date Wanted: a Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 N ■4 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit M°y`7 PERAI NO. • i 4! 4411i (206)431 -3670 El Corrections required prior to approval. $47.00 REINSPECTIPIQ FEE REQUIRED. Prior to inspection, fee ntidst be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: Proj / <+� Type of / Yl , cti4 —P-Rei _ Address: Date Called Special Instructions: Date Wanted: Wanted: 1.-Z Requester: Phone No: El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ' 1 FA PER O, . .'V ( (206)431 -3670 Corrections required prior to approval. COMMENTS: e./14-/- . S ,l -G / /pi / )� 1 - 2 ������� d Inspector: Date: ❑ S47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee mint be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pr' 'ect: • / O 1 ,4 Type of Inspection •L:, 4 //0/ A951s. 3. i Li ( iff,, V ..; Date Called6 Special I structions: Date Wanted: e.P M a.m. 0 1. Requester: Phone No: —91% INSPECTION RECORD Retain a copy with permit INSPEC1N NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I ri $47:60 REINSPE ON FEE EQUIRE . Prior to inspection, fee musttbe ` ---4 paid at 6300 Sout center Blvd., Suite 100. Call to schedule reinspection. (206)431-3670 Z.... Ej Corrections required prior to approval. Approved per applicable codes. COMMENTS: 1M/ 4d - Receipt No.: 'Date: Pr 'ect: / 1 - on, ; gO� Type of Inspection/ Iii .-- riFiiiiiF•►� 1 - MINP (� tit /14 r ate ale•: • Special Ins ructions: Date Wanted: (....? [ r\ u - - r % i _ - i* ■ Requester: r l■ -WLeikil Pho a o: INSPE6i4AI NO. 1 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 , � (2 proved per applicable codes. PERM 6)431 -3670 Corrections required prior to approval. COMMENTS: d 4- f4 -4 c • Date: El $47.00REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcen er Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Prod ct: , i / \ 6 (.,(-- -In ---/ttz- eby Type of pection: t , A ei L 5 . t a Date Called: Special InsIctions: • --- bate Wanted: grifi- Le I 1 0 ti P.m. Requester: Phonz.4. '-'-qc) - . x. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 Approved per applicable codes. PERMIT (20.)43 -3670 Corrections required prior to approval. COMMENTS: 04_ /C2 /if OD EJ $47.00 REINSPECTION VEE REQUIRED. Prior to inspection, fee must e paid at 6300 Southcenter Blvd., Suite Call to schedule reinspection. Receipt No.: 'Date: • • Ce 2 —J 00 (0 0' to 11,1 uJ p co u j 0 2 • < Ell 1- w I. ' Z I- 0 Z uj 2 M D O co O I- LIJ • 0 I- Z 0 a • 1-- 0 1- z Pro ect / A) R Corrections Type of pection �{ J • A rgss; -, • /L S L 7 Date Called: _/ c / U/ Special l In structions: //r Date Wanted: //�� ���, 60/4/2.9€ �}} !!/ a, p.m. Requester: �/��� / / / / / �-� . -S . /v 4r :!.i,. Phone No; '1;57-12Z-9/9g ..✓J rp t/ r'.. 1j Approved : per applicable codes. Corrections required prior to approval. COMMENTS: / / //r ' (.1 S .4 /v 4r :!.i,. ..✓J rp t/ r'.. / I ` A/. �_y kAt [.r - (r 1 r • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 r, }, • S 4 : /1'104 -o 6 . PERM (206)431 -3670 D $47. EINSPECTI FEE REQUIRED. Prior to inspection, fee m'st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No,.: IDate: Proj- t: • •. A 0 - t tY Type of Ins .ection: 1,..-.rfp;riittlii.....1 Date Called: 5 - ■0' - ,... 1 - / .-. 7) Add ess: q'-. it./trA4, Special Insfructions: Date Wanted: (9 o p.m• Reques.ter: t 2k{j Phone 1- No: ' -1a-409 ' • . • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)4 1-3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pz-tte' / >-7st 4-3, e_7 1 io I Date:s47 $47.00 REINSPECYION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: / Type of Inspection: Address: D at e Called: ,,-, A a 4( Special Ins . Date Wanted: e...2-, 2 4 /- 1 e/ a.m p.m. Requester Phone No: s , ,2- 7/7? INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 1 6)431 -3670 COMMENTS: M4 y- K -tO r4 ��/•r!4 � s / f proved per applicable codes. 'Corrections required prior to approval. Date�� � $47.00 REINSPECT' FEE REQUIRED. Prior to inspection, fee must e � p , paid at 6300 South enter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM • �r> } ::;i:l._ ,y`f :(1 �.:.. 7. 7 rCrp7"'�y...a , .r.Jf`.� �: >8 r City of Tukwila Fire Department Proj ect Name 4 C /[. , A/ Address 'N2 - / c9c/ ` /. Retain current inspection schedule Needs shift inspection .X Approved without correction notice Approved with correction notice issued J,/ TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief Permit No. 4.7 Suite # ‘40//e Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206 -575 -4439 04/28/2004 12:25 FAX !YOB Ws Pyre to Get Comrortablr E0•el £5L11,9L90Z Project Neme JACK IN BOX- TUKWILA Architect Engineer Purrliuer METRO AIR suemitt:d ay FERGUSON - SEATTLE COOLING; PERFORMANCE Total Capacity Sensible Capacity .Efficiency (at ARI) Part Load Efficiency Outdoor DB Temp Entering DB Ternp Entering WB Temp. 'Leaving DB Tema • Laving WB Temp Power Input (w /o;blowes) Elevation Sound Power 104 78.0 11.50 12.50 95.0 80.0 67.0 • 58.7 57.3 7.70 0 84 MBH MBH EER IPLV F F F F F KW Ft Dbels HEATING: PERT= ORMANCE Gas Fired Input i�'See. level 180 MBH Gas.FIred Output pea Level 144 MBH • • -Steady State Efficiency ' Entering DB Temp Leaving DB Temp 80.0 60.0 99.2 a% F F • SUPPLY AIR : PERFORMANCE CFM CFM IWG Side RPM HP KW BHP Tete! Supply Air Outside Air . External Static Pressure :Duct Connection Location .. Btawer Speed .'Motor Rating Power Input (blower: only) • Brake Horsepower 3400 0 0.80 887 3.0 1,55 1:95 ELECTRICAL DATA 'Power Supply • • 208 -3-60 Total Unit Ampacity • 42.7 Amps : Maximum Overcurrent Devic e Fuse Size 50 Amps HACR Circuit Breaker 50 Amps DIMENSI.ONS'& WEIGHT .Height 51 in .M411 00' .. in Depth 59 in Total Weight (inel feetery options) 1290 Lbs eL ilI AIVCES' Front 36 in Bottom' 0 in • 'Loft Side Right Side (condenser' end) Back Top 36 in 72 in 36 in 12 in ■ ��f Ultra Hi h Ef ficiency Gas /El ctric Unit Order No AUANTITY: 1 UNITS. DESIGNATION: Schedule No: 8.5 TON HI EFF r FILE COPY GENERAL FEATURE WILDING Dfi & Complete Factory Package - Tested. C'W e , Wired - Two-Stage Cooling with Independent Circuits and Face -Split Evaporator Coil • Hermetically Sealed Compressors - "Simplicity' Controls • Adjustable Belt Drive Blower - Solid Stab Contra board with Flash Code to Monitor System operation - Two -Stage Hocking with Spark Ignition - Induced than with Post Purge Logic tit Gas Fred Units RECEIVED • Bottom or Side Duet Connections CITY OF TUKW ILA - Low Voltage Relay Board With Terminal Strip - Crankcase Heaters - solid Core Liquid Line Filer Driers - Slide-out Condensate Drain Psn - Hinged Access Panels - SIIda•out Blow/ Motor Assembly - Low Ambient to Zero Degrees • Compressor And - Recycle Protection - Plug Type Wiring Harness Connectors for Economizers - Permanently Lubricated Motors - 24 Volt Conkok Circuit with Compressor Lock Out Protection - High Pressure, Low Proccuro and Freerstat Controls - Copper Tubi/Aluminum Fin Cohn - Easy Access to all Electrical Components • Rigging Holes and Forldift Slots in Base Rails for Lilting - Single Paint Power Connection - Powder Pint Finish That Meats ASTN -8117, 750 hr. 5:S Spry Test Standards - CSA Agency Aii+Droval on aN Units - Factory Warranty - One Year on the Complete Unit - Four Addakmal Years an the Compressors - Nine Additional Yews on the Oab Fired Heat Exchanger 1. UO.o map bra i rM id ee co nbuuale hopes male rro,n weed • or data. A. ■ or C rod o■anp mlaners. 2 Ursti must be instakea out atom Overnanerne natures or shnaba should nor ob Wuct ca roms's. air discMys out* SAM= v2.2Jmwary2ao4 6Y1ia[t b change Wa1 W[ netica • Mack Mai cad. 3'ILLb S P1N� Date 04/26/2004 Page 1 Model No: DH102N15S2JAE3 2002 ?tJKWIiA `APPROVED APR 2 9 2004 S NiO I E APR 2 6 2004 I50 9001 CE117IFIIO 6E :SO V06z- 9ir -Zlcid v G, Hu. Lr�ciN".' k_ . \ii.�N'Mw.3:7.vf.MY ✓�yi.W� `.' LS�u.Y3.YWi\.y;.{�j�{pM�i�:.WL' NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. a n 1 04/26/2004 12:26 FAX .Pruiacl Name JACK IN. BOX=TUKWILA Architect Purehalaer METRO AIR: • sr�inatted By FERGUSON,- :SEATTLE Date 04/2612004 Page 2 Uitra Hiiikr Efficiency Gas/El ctric Unit Order No Gerdrei troy GUANT Y: 1' °' T.UI4IT3,:DESIGNATION: schedule No: a_3 ToN HI EFF • O.3'4 5.1/4 £0'd x-1/4 LEFT ESLZL9290E Se 24 -3116 • Ge•Pipe•Inkt 07 .. 1.. VlirwotvYli %�¢ro:: iiwn Cora • Base / Pan 3 • 11 -112 ;catatonia am _ i , r , s - .- .. \ �. ter ._ Cr a 1 Paw r OutlM . r r' `'Fa 8aserail !i• I .' a A • ixa r � Dimansim9 f r. ter -- FRONT I See Detail C d Drain Dint enticing See Detail 21 te r' I —2 -3/6— 1 MEG • eagrill Di�nsien>R I a I j� - �j 1 5-3M 31iit/3S I9Ni Modal No: DH102N15S2JAE3 Union Va3 Jimmy 70011 suelttt *twos *NM Ames • CraSC* 1KCai C04U1 ,< See Detail • e \ _.. ._.-- ..- ..... - .._...- .........1 (21003 Derail 0 - Drain Dimension% 6:B@ b002-92 -I:kb J ! MJ s:�s�.hli+l:ir.ai.'...t.. a.:•! u.:.J:. „. w .....�.v,......u...,...i�.:La.= 9 04426/2004 12:26 FAX **Oct Nam* JACK iN.BOX=TUKWILA Architect Engineer Purchaser METRO AIR •Si mal..d By FERGUSON - SEATTLE QUANTITY: 1 .1JJ ITS,OESIGNATION Schedule No: 8.5 TON HI EFF Modal No: DH102N1582JAE3 lei Time to Get Com)4v1able" uffliV Air 11411 iTana t00'd £SLTL9L90Z Date u412612004 Page 3 ultra Hi ph Efficiency Gas/El ctric Unit Order No •1l- 114 -.1 241132 -rn 31.11/16- y W11 ae XT DUKESt WW2 NAL 21.114 LEFT 19 -1NC 1 ►i4' (1 V„ZE AM iliTFKE umn r.•lh r ae4IMe HAIs MOM Pawn canAq ana Cementing, Ouese w r.p Enky 13411 [139000 VE2 Januaiy 3001 611141 is chats % MMUI notes - check meal aria 31111i3S MNd 1.41111 ApR e e / z oo F RMIT c ,vt St elat,sa f� 0004 omm ivory 0£:80 VOW -9? -add /#244i% 7 04/213/2004 12:27 FAX Notes: D ❑ AWMINIZEDSTEEL OAS HEAT EXCHANGER STAINLESS STEEL GAS HEAT EXCHANGER SINGLE ENTHALPY ECONOMIZER POWER EXHAUST BAS READY ECONOMIZER BAROMETRIC RELIEF DAMPER PHASE•MONLT.OR DISCONNECT SWITCH CONV (Nan- Powered) OVERSIZED MOTOR MO i ORIZED:.OUTSIDE INTAKE AIR DAMPER (0.100 %) tr FULL PERIMETER ROOF CURB 14 FULL PERIMETER ROOF CURS 24 • FULL PERIR! ROOF CURB ROOF CURBADAPTER BURGLAR BARS SINGLE PAT: ECONOMIZER .DRY BUCK SEN DUALENTHALP1 SENSOR POWER:EXHAUST BAROM TIERIC.RELIEF DAMPER CO2 SENSOR 2 •• NATURAL GAS HIGH ALTITUDE KIT GAS PIPING KIT PROPANE CONVERSION KIT . PROPANE HIGH ALTITUDE KIT ELECTRIC. HEAT. Model No. DUCT CONNECTIONS:: Sealant ❑ Side Refer .° PRODUCT. DATA on front side for electrical data. S0'd ES4149L99Z FIELD INSTALLED II Date 04126/2004 Page 4 ULTRA HIGH EFFICIENCY GAS/ELECT PIC UNIT Order No 2.5 TON HI EFF GAS /ELE DH102N1SS2JAE3 FACTORY INSTALLED OPTIONS ACCESSORIES NoVAR CONTROLS JOHNSON CONTROLS HONEYWELL CONTROLS CPC CONTROLS DIRTY FILTER SWITCH SUPPLY AIR SMOKE DETECTOR RETURN AIR SMOKE DETECTOR TECHNICOAT CONDENSER COIL TECHNICOAT EVAPORATOR COIL OUTDOOR COIL GUARD !$r+i00$V32 Jimmy 200t Subject to thugs vetboot notice • Choc%Iccal;ataa I 005 SIMPLICITY WIRELESS EXHAUST EXTENSION KIT LOW LIMIT CONTROL PERMANENT FILTER KIT DIRTY FILTER SWITCH MINUS 60 F HEAT KIT CONDENSER COIL GUARD HAIL GUARD KIT SUPPLY AIR SMOKE DETECTOR RETURN AIR SMOKE DETECTOR MANUAL OUTSIDE AIR INTAKE DAMPER (3690 MANUAL OUTSIDE AIR INTAKE DAMPER (0- 100%) MOTORIZED OUTSIDE AIR INTAKE DAMPER (0- 100%) ZONE CONTROLS ENERGY RECOVERY VENTILATOR INDOOR THERMOSTAT 31ii113S P1Nd 02:80 VO0Z -9e -I 04/26/2004 12:27 FAX !!s Mph, Get ConrloAibir . Project Nam JACK 1N - BOX- TUKWILA Architect Engineer 'Purchaser METRO MR • Si:bmred By FERGUSON - : SEATTLE QUANTITY: 1 UNITS DESIGNATION: schedule No: 12.5 TON HI EFF 00 FB=,OR ' . NCE Total'Capaci if Sensible Capacity Efficiency (at AR» • 'Fan Load Efficiency, Outdoor DB Temp Entering DB Temp .Entering WS Temp .Leaving D8 Temp Leaving W8 Temp: .Power input (w /a:blower) :Elevation .Sound Power _HEATING_PERFORMANC Gas Fired Input.O:SewwL evel. 180 MBH 'GQs Fired Output t&Seattt even 144 MBH • :Steady State Effideru y • .. , 80.0 'Entering DB Temp: 60.0 'Leaving DR • • • 857 F 'SUPPLY AIR°BLOWER•PERFORMANCE 1:70tai•8upply Air 5000 CFM Outside Air 0 CFM .`External Static Pressure 0.80 IWG Duct Connection Location Blower Speed Motor Rating ' Power Input (blower only) ;�8rake Horsepower • 90'd ESL tL9L9ga 159 116 10.00 10.70 95.0 80.0 67.0 • 58.5 56.9 13.10 0 . 90 1075 5.0 3.23 3.46 ft� Mid.. Efficiency Gas /Elect c Unit MBH MBH LER IPLV F F F F F KW Ft Dbels Side RPM HP KW BHP maw subliettachenaewMletnotice - CMCklealcodee 31111335 MNd Date 04/26/2004 Page 5 Order No Model No: DH160N1552JAC3 1e.1006 GENERAL FEATURES • Complete Factory Paclwga - Tad, Charged, Wired - Two •Stage Cooling with Independent Circuits and Fece -Split Evaporator Co% - Hermetically Sealed Compressors 'Simplicity' Controls Adjustable Belt Drive Blower - Solid State Control Board with Flash Code to Monitor System Operation - Two-Stage Heating with Spark Ignition - induced 0mtt with Pent Purge Login en Gas Fired Units - Bottom or Sloe Duct Connections - Low Voltage Relay Boat With Terminal Strip - .Crankcase Hasten - solid Core Liquid Line Filter °nets SI de out Condensate Drain Pan r ELECTRICAL: DATA • Power Supply 208 -3 -60 Total •Unit Ampacity 68.8 Amps Maximum Overt urieniDevice • Fuse Size . . 50 Amps HACR Circuit Breaker • • 80 Amps DIMENSIONS& WEIGHT Height 51 in .' 1Alldtk8g; in ,Depth 59 in Total •Weight•(incl lactory.,options)1324 Lbs CLEARANCES :Front 36• in :• Bottom' 0 In Lett Side ' Right Side (condenser• end) Back Top' 36 in 72 in 36 in 12 in a - Hinged Access Panels - Slide-out Street/ Motor Asaembry - Low Ambient to Zero Degrees . Composer Ant - Recycle Protection - Plug -Type Wiring mamas Connectors for Economizers • PermsnenUy Lubricated Motors - 24 Veit Contra Circuit with Cerapre•.,dor Lock Out Protection High Pressure, Low Pressure and Freerstet Controls - Capper Tubs/Aluminum Fin Coils - Easy Access to all Electrical Components • Rigging Holes and Forkfif Slots in Base Rails for Lilting - Single Point Pettier Connection • Powder Paint Finish That Meets AST/44117, 73C Ar. Salt Spray Test Standards - CSA Agency Approval on ail Units - Factory Warranty - One Year on the Complete Unit - tour AndittOnel Years an the Cornpfesent6 - Nine Additional Years on the Gas Fired Heat Exchanger 1. Unds may be inshtred an combustible NMI mode from wood or duo A, a or C roof cowing maewialf. 2 units mugs. installed out doors, Dwranpna svunwn or Webs should not °Select condoms w docbrBo as*. CEaTfele0 0E :80 P002- 9z —BdH 04/26/2004 12:28 FAX • IIIYORK Time to Get Comfortable". : Project Name JACK IN TUKWILA Arehllsd Erwi eer Porciuser METRO 'AIR s; - 1CIea By FERGUSON - SEATTLE QUANTITY: 1 ,, „UNITS. DESIGNATION: Schedule No: 12.5 TON Hi 6FF • Model Nei: OKI8ON1532JAC3 SCI-314 • • 55114 `3a11r32 4-1/4 30.3/1877 1 Z - 2 V . 18 50 24.3N8 LEFT ,oft: pipe Inlet • Bose 017:13/18: - ,', ! Pan c L VNw ctYl ll Acme lean CoU COMM 2 d £SLIL9L902 /�rE i/1 % 1' Date 04/26/2004 Page 6 Mid. Efficiency GaslEle c Unit Order No 81-3/113 'For aaeeraii Dimtndans FRONT .491 s a Dated :: %.� , For Drain . Dlriumsions 1 See Delon D - -- r f . 27 I __Air • ' 24/8 � li 3-314 3.9116 -) I 5-318 ..... _......... .__ ._.,....._..... ._.,- ........... ( 1 EaP2:C7 V3.a January 7004 34000 to mange W tAi: Ewa - Chock lows codes Detail C - 3ueraii Dimensions pd.ii D - Dtein Dimensions Li/ 007 3111ti3S ('1Nd T2:80 000E -9Z —add z O W JU U O cn W W O gQ S Detail w D sCI I— la ? � H O z l— W U � OFP- 0 H r Z U =: O~ z 04/28/2004 12:28 FAX 11/4 WOW '•.! Ame to Gee Co+nffwtlble` • Pieject NRme JACK INS BOXr TUKWILA Itictrtecl. . P:it:haaet METRO AIR,.. .sldomNfed By FERGUSON -.SEATTLE QUANTITY: 1 UNITS. DESIGNATION: schedule No: 126 TON HI EFF 1 -114 / # 4L 1 % Date 04126/2004 Page 7 Mid. Efficiency GaslEleet c Unit Order No 1141O WSW I E1JEFO .PLZR thorn: oenotaL 2R•1/4 VAMP P V3.1 JIIINOIy ZOOe SOW'S Is GNAW * *Sat Wen - Check loco) codes Model No: DH1SON1SS2JAC3 RECEIVED OITY OF TIIKWII A APR 2 6 2004 PERMIT CENTER Z 008 31.11U SS S (1Nd T£ :60 POO2 - 8dd _w:li.:, fr', XiiiRL• S�: i::' KYfl�.,. �i% 1��1M'-' . u} ER '.Vx.Utl.:.iw��ilu±tii':ict4't1 Gic:4�!i1': {IZtb +�?3:J:•a: ..�— �,t- •1:.: 04/28/2004 12:28 FAX • It's Time to Get Comforible Notes: ALUMINIZED STEEL GAS HEAT EXCHANGER STAINLESS STEEL GAS HEAT EXCHANGER SINGLE ENTHALPY ECONOMIZER POWER EXHAUST BAS READY•ECONOMIZER BAROMETRIC.RELIEF DAMPER PHASE;MONITOR DISCONNECT SWITCH CONVENIE,NCE:OUTLET (Non- Pavared) OVERSIZEQ:11LOW ER .MOTOR MOTORIZED.OUTSIDE INTAKE AIR DAMPER (0.100%) 8` FULL PERIMETER ROOF CURB 14" FULL PERIMETER ROOF CURB 24 ":PULL• PERIPA R:ROOF CURB ROOF CURD'ADAPTER dURGU1R.BARS • • SINGLE INPt1T ECONOMIZER DRY BULB SENSOR DUAL ENTkALPY. SENSOR POWER EXHAUST. BAROMETERIC RELIEF DAMPER CO2 SENSOR. • NATURAL GAS HIGH ALTITUDE KIT GAS PIPING,KIIT. PROPANE•CONYERSION KjT PROPANE•HIGH;ALTITUDE KIT ELECTRICHEAT. Model Na. DUCT CONNE¢Z E1. S. •. RoNom 0 Side [Jf • Rafts to PROD UCT DATA side for electrical data. 60'd ES4T49L90E f 111 MID. EFFICIENCY GAS/ELECTRIC UNIT 12.5 TON HI EFF GAS /ELE DH150N15S2JAC3 FACTORY INSTALLED OPTIONS FIELD INSTALLED ACCESSORIES NOVAR CONTROLS JOHNSON CONTROLS HONEYWELL CONTROLS CPC CONTROLS DIRTY FILTER SWITCH SUPPLY AIR SMOKE DETECTOR RETURN AIR SMOKE DETECTOR TECHNICOAT CONDENSER COIL TECHNICOAT EVAPORATOR COIL OUTDOOR COIL GUARD !SPUN VI,2Jmvoty2031 Saint aaMeaeWillem%sauce • Check local vides X 009 Date 04/28/2004 Page 8 Order No SIMPLICITYTM WIRELESS EXHAUST EXTENSION KIT LOW LIMIT CONTROL PERMANENT FILTER KIT DIRTY FILTER SWITCH MINUS 60 F HEAT KIT CONDENSER COIL GUARD HAIL GUARD KIT SUPPLY AIR SMOKE DETECTOR RETURN AIR SMOKE DETECTOR MANUAL OUTSIDE AIR INTAKE DAMPER (35%) MANUAL OUTSIDE AiR INTAKE DAMPER (0.100%) MOTORIZED OUTSIDE AIR INTAKE DAMPER (0-100%) 2ONti CONTROLS ENERGY RECOVERY VENTILATOR INDOOR THERMOSTAT ISO 9001 eeatorIca 311.1U3S P1Nd T£:80 V002 -9E -&J DEPARTMENT : ,44 Buil ing'Divi i n Public Works ❑ Documents /routing slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M04 -067 PROJECT NAME: JACK IN THE BOX SITE ADDRESS: 3742 S 144 STREET DATE: 04 -26 -04 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # afteribefore permit is issued 512 Auk, +28 Fire Prevention El I Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -27 -04 Complete [Z Incomplete ❑ Comments: TUES/THURS RO9TING: Please Route Lvi Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: PERMIT COORD COPY REVIEWER'S INITIALS: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 05 -25 -04 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments Issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: �..w)u�.'_i..ti.:uLv.;..1f:' , ... •.li: "' � �1. "., 'r.h�s:'u:.t.�✓1fw • . . e' • . 4 • - - - •••••*: • - -*- 19p.O.C61/z • • !- - • St) • - • : LVI3 • : . • - - • OSNO sf mt da •• _ • ..... . , :;-:- - • • . . - • • SHIIIISIK/Ni (NV 11 • ; EE0 67 14144 ' . Z. • • • - • .: • . • rd i CALLSW . I %ETV , - -'• I -4;Atia , . NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR1HAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. _ _ • 1'-20' SURVEYOR'S NOTES 1. THIS "ALTA /ACSM LAND TITLE SURVEY" IS IN ACCORDANCE WITH "MINIMUM STANDARD DETAIL REQUIREMENTS FOR ALTA /ACSM LAND TITLE SURVEYS" JOINTLY ESTABLISHED AND ADOPTED BY THE AMERICAN LAND TITLE ASSOCIATION AND AMERICAN CONGRESS ON SURVEYING AND MAPPING IN 1999. 2. THIS DRAWING COMPUES WITH NATIONAL MAP ACCURACY STANDARDS FOR A TWO -FOOT CONTOUR INTERVAL AND DRAWING SCALE OF 1 " = 20'. UNAUTHORIZED ENLARGEMENTS MAY EXCEED THESE STANDARDS. 3. HORIZONTAL DATUM IS NAD 1983 (91), BASED ON INFORMATION PUBLISHED BY THE CITY OF TUKWILA. WE HELD CITY OF TUKWILA (COT) MONUMENT NO. 1925 FOR POSITION AND A BEARING OF NORTH 0714'05" EAST TOWARD COT NO. 461. 4. VERTICAL DATUM IS NAVD 1988, BASED ON INFORMATION PUBLISHED BY THE CITY OF TUKWILA. BENCHMARK IS COT NO. 19; FOUND PK NAIL W/ PANEL AT ENTRANCE TO APARTMENT BUILDING, SOUTH SIDE S. 140TH STREET AT 38TH AVENUE S. ELEVATION = 289.01 FEET. 5. ALL TITLE INFORMATION SHOWN ON THIS MAP HAS BEEN EXTRACTED FROM FIRST AMERICAN TITLE INSURANCE COMPANY COMMITMENT NO. 46442A, DATED AUGUST 28, 2003. IN PREPARING THIS MAP. BARGHAUSEN CONSULTING ENGINEERS. INC. HAS CONDUCTED NO INDEPENDENT TITLE SEARCH NOR IS BARGHAUSEN CONSULTING ENGINEERS, INC. AWARE OF ANY TITLE ISSUES AFFECTING THE SURVEYED PROPERTY OTHER THAN THOSE SHOWN ON THE MAP AND DISCLOSED BY THE REFERENCED FIRST AMERICAN COMMITMENT. BARGHAUSEN CONSULTING ENGINEERS, INC. HAS REUED WHOLLY ON FIRST AMERICAN'S REPRESENTATIONS OF THE TITLE'S CONDITION TO PREPARE THIS SURVEY AND THEREFORE BARGHAUSEN CONSULTING ENGINEERS, INC. QUALIFIES THE MAP'S ACCURACY AND COMPLETENESS TO THAT EXTENT. 6. PROPERTY AREA = 21,003 ± SQUARE FEET (0.482 ± ACRES). 7. THIS PROPERTY HAS LEGAL ACCESS TO PACIFIC HIGHWAY SOUTH AND SOUTH 144TH STREET, SHOWN HEREON AS PUBLIC RIGHTS -OF -WAY. PHYSICAL ACCESS MAY BE LIMITED BY IMPROVEMENTS, OR LACK THEREOF, AS SHOWN ON THE SURVEY. 8. TAX PARCEL NUMBER ON THE SUBJECT PROPERTY IS: 152304929507. 9. ZONING: NEIGHBORHOOD COMMERCIAL CENTER (NCC), TUKWILA, WA. 10. CURRENT MINIMUM BUILDING SETBACKS: 12' FRONT ( TUKWILA INTERNATIONAL BOULEVARD); 5' SECOND FRONT (S. 144TH ST.); 10' REAR; 10' SIDES MINIMUM PER THE CITY OF TUKWILA MUNICIPAL CODE. PLEASE CONSULT THE CITY OF TUKWILA MUNICIPAL CODE FOR FULL PARTICULARS. 11. BUILDING LOCATION DIMENSIONS ARE AS MEASURED AT RIGHT ANGLES FROM PROPERTY LINE TO BUILDING CORNERS AT POSITIONS INDICATED. (UNLESS SHOWN OTHERWISE.) 12. STRIPED PARKING STALLS AND STALL DESIGNATIONS SHOWN HEREON ARE AS THEY ARE MARKED ON THE GROUND. OTHER PORTIONS OF THE SITE NOT MARKED ARE ALSO USED FOR PARKING VEHICLES. 13. FLOOD ZONE DESIGNATION = X, AREA DETERMINED TO BE OUTSIDE OF 500 -YEAR FLOODPLAIN, ACCORDING TO FLOOD INSURANCE RATE MAP, ( "FIRM") NO. 5303300960 F, COMMUNITY NO. 530091, (CITY OF TUKWILA), PANEL NO. 0960, SUFFIX F, EFFECTIVE MAY 16, 1995, KING COUNTY, WASHINGTON, AS PREPARED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY ( "FEMA"). 14. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST ON THIS SITE. ONLY THOSE UTILITIES WITH EVIDENCE OF THEIR INSTALLATION VISIBLE AT GROUND SURFACE ARE SHOWN HEREON. UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY. UNDERGROUND CONNECTIONS ARE SHOWN AS STRAIGHT LINES BETWEEN SURFACE UTILITY LOCATIONS BUT MAY CONTAIN BENDS OR CURVES NOT SHOWN. SOME UNDERGROUND LOCATIONS SHOWN HEREON MAY HAVE BEEN TAKEN FROM PUBUC RECORDS. BARGHAUSEN CONSULTING ENGINEERS, INC. ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBUC RECORDS. 15. THIS SURVEY REPRESENTS VISIBLE PHYSICAL IMPROVEMENT CONDITIONS EXISTING ON NOVEMBER 3, 2003. AU. SURVEY CONTROL INDICATED AS "FOUND" WAS RECOVERED FOR THIS PROJECT IN OCTOBER AND NOVEMBER OF 2003. 16. ALL DISTANCES ARE IN FEET (U.S. SURVEY FEET). 17. THIS IS A FIELD TRAVERSE SURVEY. A SOKKIA FIE- SECOND ELECTRONIC TOTAL STATION WAS USED TO MEASURE THE ANGULAR AND DISTANCE RELATIONSHIPS BETWEEN THE CONTROLLING MONUMENTATION AS SHOWN. CLOSURE RATIOS OF THE TRAVERSE MET OR EXCEEDED THOSE SPECIFIED IN WAC 332 130 - 090. ALL INSTRUMENTS AND EQUIPMENT HAVE BEEN MAINTAINED IN ADJUSTMENT ACCORDING TO MANUFACTURERS' SPECIFICATIONS. 18. THIS SURVEY WAS PREPARED FOR THE EXCLUSIVE USE OF FOODMAKER, INC.; JACK IN THE BOX, INC.; AND FIRST AMERICAN TITLE INSURANCE COMPANY. RIGHTS TO RELY ON OR USE THIS SURVEY DO NOT EXTEND TO ANY UNNAMED PARTY WITHOUT EXPRESS RECERTIFICATION BY BARGHAUSEN CONSULTING ENGINEERS, INC. AND /OR THE PROFESSIONAL LAND SURVEYOR WHOSE SEAL APPEARS HEREON. E . XISTING ITC/TACO BELL REM RANT p.F. -.. 303.64 :fit.= 314.18 \. ..0,'tiC. P • - 7.17F' T ]1 • : « a.�+. OUTH 144th MOYSiatiLEUM GKIIIOIi O UTIUTIES AND THIS w. OF F Myk 7 7/"1- CROSS-HATCHING INDICATING OUTRIGGER CROSS HATCH TO BE PLACED ON 4' INTERVALS AND LETTERING TO BE A MN. 24' N HEIGHT. MARKERS TO BE HOT APPLIED AND SHALL EXTEND 2' OUTSIDE PERIMETER OF GREASE INTERCEPTOR VAULT , \- CB "TYPE 1 RIM =309.• ✓' IE. 8" DI SW =306.42 IE 12 CNC F =306.42 a EX CA8 METER AND SERI/ICE TO REMAIN "DRIVE EX. POWER METER AND SERVICE TO REMAIN DRIVEWAY CONNTRAC;TOR SHALL BE FULLY RESPONSIBLE FOR OBTANDNG PERMITS FROM THE WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES FOR REMOVING AID REPLACING ALL SURVEY MONUMENTATION THAT MAY BE AFFECTED BY CONSTRUCTION TO WAIL 332 -120. APPLICATIONS MUST BE COMPLETED BY A RED LAND SURVENOR. APPUCATIONS FOR PERMITS TO REMOVE MONUAIENTS MAY BE OBT/MIED FROM THE WASHINGTON STATE DEPARTMENT OF NATURAL AL OR 8Y CONTACTING THEIR OFFICE By TEUEPHONE AT (300) 902 -1190. wispearoti STATE DEPARTMENT OF NATURAL PUDIC LAID SURVEY OFFICE 1111 WASHIPIGTON STREET S.E. P.O. SOX 47000 OLYMPIA, IIRSHINGTON 98504 -7000 UPON COMPLETION OF CONSTRUCTION, ALL MONUMENTS DISPLACED, REMOVED, OR DESTROYED SOU. BE REPLACED BY A REGISTERED LAM SURVEYOR, AT TIE COST AID AT APPROPRIATE THE DIRECTION OF THE CONTRACTOR, P RStMT TO THESE REGULATIONS. TIC RESPONSIBUTY OF THE camacron. FORMS FOR REPLACEIENT OF SND MONUMENTATION SHALL ALSO BE TINE CIVIL SITE AND UTILITY PLAN CB TYPE 1 . IM = 303.76 IE 12" 'I E= 301.36 IE 12" C' C W= 301.96 ` � cip Y STREET STRIP E E WHIT STRIPE PROPOSED TYPE I CATCH BASIN PROPOSED TYPE I CATCH S*S EXISTING TYPE N CATCH BASIN EXISTING TYPE I CATCH dKS1N PROPOSED STORM DR N ,1E LIME EXISTING =MOM OPPN MME LNIE PROPOSED SAMTARY SEWER LINE PROOMED WORMY MINOR 11100140LE PRIONIMED WORMY San CILIONNT MING WNW MOW OWING WSW SEINER LIME SEE ARCH. WE PLAN .TEL. VAULT-' POWER POLE --" w /LUMINIARE w /UG DROP UGH\ BASE 0 P TYPE 1 RIM -30\82 IE 12 E= IE 12" DI W =299. L EASEMENT "A" RECORDED UNDER REC. NO. 20020416003153 • U IU • • 0 3 , TUKWWILA SITE INSPECTOR WIWIWIMM ST WV // / // // / / SIGNAL CABINET // r/ SIGN1 POLE TEL. VAULT �-- SSMH RIM =301.32 IE 8" CNC N= 295.95 lE 8" CNC 5= 295.02 IE 8" CNC W= 295.35 EXISTING MI'ERIIIM EXISTING ARE HYDRANT EXISTING %WM VALVE PROPOSED WATERMANr PROPOSED FIRE HYTOR* PROPOSED WINTER WOE PROPOSED coNaiETE POCIPOINED SPOT EMMONS MONO SPOT EMMONS ammo COMM PnDPOSLD COMM PROPOSED U ff' PMENDIT LIGHT BASE --\\ \ )-16' ,I -BOX to OD CO // // // // GAS SALVE r // // // r r // // /IEASEMENT "B RECORDED UNDER I/ REC. NO. 20020416003 63 C ,�. ` _ --.__ / � GROUND ROD 30p CB RIM= 300.51 IE 12" DI W= 298.03 IE 18" DI 5= 296.77 IE 18" DI N= 296.77 •. �,,,r.. --� LIGHT J -BOX • LIGHT BASE C3 TYPE 1 RIM =298.21 IE 18" DI S =294.30 IE 18" ADS N =294.25 1E 12" ADS W=294.2 / LIGh j--BCx uGH T BASE 02 - LIGHT U -BOX / 0 PORTION CONVEYED 10 STATE OF WASHINGTON FOR ROAD PURLS ' BY DEED RECORDED I I N UNDER RECORDING NO. 9512140574 564'23'30V 100 100 • ►. • ; . • , .298 EX. WATT LETER AND BBiVICE TO REMAIN . Baia FOR DIMENEIONED ilrrEE PLAN SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL E gELECTRICI►L dPLUMB11Ki ((GAS PIPING CITY OF TUKWILA BUILDING DMSION LEGAL DESCRIPTION THAT PORTION OF THE SOUTHEAST QUARTER OF THE SOUTHWEST QUARTER OF SECTION 15, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., PI KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEit>IN NI NG AT THE NNTTERSECTION OF THE NORTH UNE OF THE SOUTH 20 FEET OF SAID SUMMON WITH THE WESTERLY RIGHT- OF-WAY LAME OF PACIFIC SAY SOUTH; THENCE NORTH 20' 13' 20' EAST ALONG SND WESTERLY RIGHT -OF -WAY LINE 138.16 FEET TO THE NORTH UNE OF THE SOUTH 151.54 FEET OF SAD SUMMON (AS MEASURED ALONG THE WELT UNE THEREOF); THENCE NORTH 87 35' 3Y' WEST ALONG SAID NORTH UNE 184.27 FEET TO THE EAST LIE OF THE WEST 359.70 FEET (AS MEASURED ALONG THE SOUTH UNE) OF SAID SUBDNISION; THENCE SOUTH 02' 14' 27" WEST, 131.54 FEET TO SAID NORTH UNE OF THE SOUTH 20 FEET OF SAID SUBDIV ON; THENCE / �SOUTH 87' 35' 33' EAST ALONG SAID NORTH LINE 141.62 FEET TO THE POINT OF PO • EXCEPT THAT PORTION THEREOF CONVEYED TO THE STATE OF WASHINGTON FOR ROAD PURPOSES BY DEEC RECORDED UNDER RECORDING NO. 9512140574. ESTIMATED EARTHWORK VOLUMES: CUT - 100 C.Y. RIL is 100 C.Y. IAPEIWIOUS AREA CALCULATION EXISTING IIPERviOUS AREA '19,800 SF. PROPOSED IMPERVIOUS AREA - 16,800 SF. roex OF ors C1.0 C1.1 PS1.0 1 fir I v • r, , L P E T i - C v y A ,E C . *ILL r � d ,�C A,01 4it''_d f� .k. ) MAY ! Zt litre r_ " P VICINITY MAP CIVIL SITE AND UTILITY PLAN CONSTRUCTION NOTES AND DETAILS GREASE INTERCEPTOR PLAN FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. 11Y Of IONIttA PPPRONIE APR 2 9 22tIt tt t DWG err q APR 16 2004 t t- �1:1i4Ma' RELEASE: P.M.(J8 ONLY): PERMIT: ND: T101% M • N CO 04 N 1 r '' 3 n n in Cs' CNI • 04. in N Z N • NC DRAWN BY: PT SCAM: 1' C1.0 MO BALBOA AVINUE SIN OEM CA 02123 ©1999 Jock in the Box Inc. Moss drawings end ere the property et Jesk end Own net be espied er r preiNM ellheut Its pretteue written eot. VI/04 DESIGN REMO Z■E 1 ci• N site information MK TYPE: JIB ft 8365 ADDRESS` S. 144TH ST. a INTERNiATIONML BLVD. CITY OF TUKWILA, WA ML 81TE AND unmY PLAN 4 0 N 0 V V 0 T N G M C V C C V 0 ri • • L 8' -11 3/4' REF. • EXHAUST /MBA CONTROL PAIQ t Y-8 1/2 tom\ \V Rff. REF. EL r -- , +D" I i;) REMOTE DOMING MANSARD ROOF. 7 .. REF. 1 HEATER FLUE 2'-O' M04E PARAPET. EL +44' . — EL +46' EL. +14' • DUCTING ENTERS ADJOINING PLENUM PER TECHNICAL RIDGE LPE DUCTING ENTERS ADdONING PLENUM PER MECHANICAL CLASS 'A 'A' GILT -UP-UP PROMDE NEW V i� ROOFING - SEE SPECS. r -2 7/n' REF. 3 -4' 3 -4' i i REF. ' ' REF. I MACHINE � I NNEMI ICE 'MACHINE ICOND. UNIT - � 1 a aD MOO CRICKET TV. ROOF PLAN NOTES SEE STRUCTURAL ROOF IRS PLAN FOR PLYWOOD AND FR INFORIIAlION. 2. SEE IiECHANNCAL ROOF PLANS F . • DON OF MECHANICAL, EQUIPMENT. 3. FOR TYPICAL VENT DETAIL SEE 4. FOR PLUMBING ROOF PENETRATIONS TO ICE YANK CONDEMN UNITS. SEE 5. HVAC UNITS INCLUDING AC UNITS. EXHAUST FANS AND MAKE UP MR (F USED) SHALL BE HOISTED, SET IN PLACE AND SECURED TO ROOF CURBS BY G.C. S. , IN BOX ROOF TOP UNIT SHALL BE HOISTED. SET 14 PLACE ANA SECURED R OOF CURB BY G.C. 7. ICE MACHINE ROOF TOP UNITS SHALL BE HOISTED, SET IN PLACE AND SECURED TO ROOF CURB BY ICE MACHINE INSTALLER. B. NALL AND PATCH ALL UNUSED PENETRATIONS TO MATCH ADJACENT SURFACES. 1. 9. REMOVE EXISTING MECHANICAL UNITS. 10. REMOVE DOSING EXHAUST FANS. 11. REMOVE ANY EXISTING SURFACE MOUNTED GAS LINES AND RE—ROOTS IN ATTIC 12. 13. SPACE. VERIFY EXACT UNITS ARE SHOW IN APPROXIMATE LOCATIONS. FIELD LOCAMON. G.C. TO USE EXISTING LOCATIONS MERE POSSIBLE AND MODIFY CURBS AND ROUGH OPENING'S AS NEEDED, REMOVE DOSING ROOFING AND SHEATHING AS NECESSARY TO INSTALL NEW WORK. L .�_ 3 -- 014 VOIlik Ail 2S WA ha 1 r rtS1 APR 2 2004 1 Li 67 0330 9AL90A MOUE SAN X00: G 91123 These drawings and ono the property of Deck I .silt : and shell not be mild ar re/redneed Wisest its previous written aansont, dotes RELEASE: AUG. 5, 2002 P.U.(JB ONLY): f5 12 -31 -02 PERMIT: 1/14/04 1/27/04 CONSTRUCTION: revisions site information M( TYPE: CONVERSION •� 8365 ADDRESS: 3742 S. 144TH STREET TUKWILA,, WA SCALE: 1/4' ARCHITECTURAL ROOF PLAN p LATERAL LOADS M BASIC MID SPEED ' 00 Y.P.H. , EkP061JRF I SEISMIC ZONE v - ZC ' w. 0.117W Coal .0.3NR•4.5 3 GRAVITY LOADS FLAT ROOF DEAD 16.0 P.S.F. UVE - 20.0 P.S.F. SNOW 25.0 P.S.F. • ADDITIONAL 2x10 OF11 IN WS28 •11 O EACH SSE OF MECHANICAL 4 f i i 1 I LECIII UNI T '1550 LBS 1 � I I JECIII UNIT 155►0 LBS I i ! I II II H 11 IwJ I I; !r. A01 AL $ x10 W1 EACH EDGE OF I ¶Nt ws2J1 I I I 0 9iXG. 428 TYP. I I I AMORAL (a)—axio DF EDGE OF ME IVERIFIY U128 DESIGN LOADS: 1. '1HE SCHEDULES BELOW LIST NE 1997 UNIFORM BUADING CODE GRAVITY AND LATERAL DESIGN LOADS USED FOR THIS BUNS 26 PBS earns GROW HOOD It I ADDITIONAL • 0 DF M � 0 EDGE OF 111 AS I1 1SHOVE ! I I ADO S ( 2 2x10 /1 I , �: 2 tow, SIDE ' kiECHANICAL UPPER ROOF FRAMING NOTES S SEISMIC LOAD IS REDUCED BY FACTOR OF 1.4 TO ACCOUNT FOR ALLOWABLE STRESS DESIGN. r - r GENERAL: 1. SEE ROOF FRAMING PLAN FOR SiEARwALL SCHEDULE i Aaa1011AL FRAYING INFORYA11ON. Z SEE MO W& ROOF PLAN FOR LOCATION OF MECHANICAL C NT. 3. LOADS SHOWN FOR MECHANI . EQUIPMENT ARE FOR 1RUSS OESNNN PURPOSES ONLY. REFER TO MECHANICAL PLANS FOR ACTUAL OPERA1 NG NEWTS. 4. FOR TYPICAL TOP PLANE SPLICE SEE 5. FOR TYPICAL MECHANICAL CURB ATTACHMDIT SEE ri A �� PR 4 6 2004 C 4 • • A O I DEPARTMENT 9330 BALBOA AVENUE SAW DIEGO, CA 92123 ©1999 Jody In the Boo Inc. Theft drawings and specifications aro the property of Jamb in the Sal Mme and 00 not be copied or reproduced without its precious written consent. RELEASE: AUG. 5, 2002 ONLY 5 12 31 - 02, 01/14/04 PERMIT: dates CONSTRUCTION: 03/15/04 8 *44 a Syr ! 4e cip revisions 4AiAj,8N �� 1R site information UK TYPE: CONVERSION .11EI f 8365 ADDRESS: 3742 S. 144TH STREET TUKWILA, WA DRAINI! BY: IRON / HJA SCALE 114 " = 1` — UPPER ROOF FRAMING PLAN S3.0 • GRIDDLE =ODLE REV 1 DATE QTY gnome DENIM IIIIIIIII NEI P PINI ART NO. r r MLAUFr�-vr� alEFATratyl SIDE E PANELS 0 0 PAIf1IDE AND INSTALL • 'r �� AID FACTORY nix MOUNTING w n ►a� EtraL HOT 110.E STEEL AND CUT STACK TO LENGTH A FIELD MOD H000 i' FAN EXHAUST FAN CURB MAKEUP AIR SUPPLY FAN ., 1 1 FAN 1n FROM MOTOR STARTERS AID COMPONDITS 10 IIIERLOCK TO SUPPRESSOR Ste. QTY 1 1 1 2 2 1 20 1 1 1 5 AS REQD AS READ AS READ 1 1 1 1 PART NO. 503203 503205 503221 500346 503168 503442 500354 503406 500352 500360 503225 503217 503176 • .. 1 CORNER PULLEY ELBOWS �41J671 CO2 CARTRIDGE FOR AUTOMAN 1s - + :..1 GAS VALVE 1 1/2" MECHANICAL W/ CYUNOER AND TUBING HOOD PREPPING WITH NOZZLES FACTORY INSTALLED IN HOOD DETECTOR BRACKET TERMINAL FACTORY INSTALLED IN HOOD DETECTOR BRACKETS SERIES FACTORY INSTALLED IN HOOD 3/8" B.I.P PIPE, SCH 40 FOR SUPPLY LS 3/8" B.I.P. PIPE FITTINGS FOR SUPPLY LINES 1/2• EMT TUBE FOR DETECTOR UNE INSTALL SYSTEM PIPING AND SYSTEM COMPONENTS INSTALL GAS VALVE AND INTERLOCK TO MIQROSSITC H INSTALL REMOTE MANUAL PUU. AND CONDUIT OUT of TOP OF WALL. LL INSTALL REMOTE PU PROTECTOR SUPPLIED BY: EXHAUST HOOD SYSTEM HOOD w tifif �I1woD Restriat GRIOpLGRIDDLE/FRYER R EXHAUST STACK INSULATION PER LOCAL COOS UNE M 1 1 SUPPLY PL.ENUUM I © ► 17i ;j ]' ry :• .+ 1117 IN HOOD SUPPLY PLENUM %WRING OF ALL RECEPTACLES OF HOOD PLENUM AND 1MER E1NCLS DESCRIPTION DESCRDESCRIPTION � P.w. FIRE PROTECTION SYSTEM HOODS 01 AND 112 GRIDDLE HOOD AND FRYER DESCRIPTION to GALLON ANS>1UL SYSTEM 3.0 GALLON ANSUL AUTOMAN REG. RELEASE ASSEMBLY #79290 3.0 GAL ANSUL CYLINDER W/ MOUNTING BRACKET 3.0 GALLON ANSULEX AGENT /79372 5 DEGREE DETECTOR LINK REMOTE MANUAL PULL REMOTE MANUAL PULL BOX 4" OCTAGONAL RACO #165 DETECTOR CABLE 100 FT. LENGTH ANSUL ELECTRIC SWITCH #32220 4PDT - FIELD INSTALLED dates RELEASE: AUG. 5, 2002 P.U.(JB ONLY} 15 12-31-02 PERMIT: 1/12/04 BID: CONSTRUCTION: 11#; ggil ENgsi ad:I • y ... M Nil! • 0 ete g • r••N O b0 revisions • site information MN( TYPE: CONVERSION .AB # 8365 AD ORE& 3742 S. 144TH STREET - , .r. 7.5 25 . 1 r • ,� t.�M JUNCTION LI SOX FOR HOOD U 4TS POS CHASE a M INFI 10X. HOOD #1 HOOD #2 - v • WRE T / (2 20AMP DUPLEX ACLES (PREMED) 1 CIRCUIT HOOD TO PLENUM AT FLANGES 1W. BOTH SIDES. (3) L6 --13R TMISILOC K RE TACL.ES (PRE MIRED) (3) SEPERA mains FINISHED FLOOR s�1� I REQUcIrt N C�ND n 000 ate DESCRIPTION 4 •41., sreso 3/4" CONDUIT TO HOOD TOP. 0.750' -� it I 92* LOW PROFILE EXHAUST HOOD 68" LOW PROFILE EXHAUST HOOD OEIEK.WIt tat 0500" 2." WNW OVERHANG 101 uLNC •V FR11E:R H000 A 0 oE CION LNC (2) OPEN 1' X 43.500" INSULATION CAVITIES INSULATION OPTIONAL BY MARSHALL DOMED BACK I' s . F ( I k< `?I I, FRONT VIEW � '` -� • ''� ''� �► P. RIGHT SIDE VIEW ,.�, r►. HOOD #1 - 92" GRIDDLE/FRYER 10CENTER OF RECEPTACLES SI I FACTORY G 0 3195 7' -8" 92.000" TOP VIEW 27.000" 15.000" 10.00 4" X 4" JIANCflON BOX FOR RECEPTACLE MIRING HOOD TOP - 11GHT. CONTNIOUS MELD POS CHASE-‘ (2) 20A DUPLEX FACTORY INSTALLED AND MtIRED N TIMER ENCLOSURE � err CONDUIT L;A HOLES L T 1. " FiOR 1 MS AR 43 S MO BUMP BAIL 5,000" 29.875" r TIMER ENCLOSURE DETAIL EXHAUST CFM 1885 1310 VENTILATION SYSTEM INFORMATION MAKEUP AIR 755 525 1280 26.000" 26.000" D L9 ©© MO 0E0 LNC NUMBER FAN MODEL * • * BY OTHERS 3/V SUPPLY TOE 10 HOOD 12.125' X 12.125' EXHAUST OOLLAR FOR 12" X 12" STACK MOO alu STACK NOT PPROb BY B MARSFNAU.� mST 4* X 21' COLLAR TIP• (2) FELD LOCATE AND CU TOP BY INSTALLER 1 1/e GAS LN E CONNECTION 1 EAT CONDUIT /�F'A�CTORY WENDED TO 14ND Ig FOR COMltCIIQN S1 ` 2.250" `3.000 L 2.000" 1.938" FACTORY MEND ED TO 11000 TROP. FOR CONNECTION OF F SYSTEM PANG. JUNCTION BOX FOR TIMER RECEPTACLES, 24" MIRE LEADS IN JUNCTION BOX. HANGER BRACKETS FACTORY MENDED ,.• �• TO HOOD TOP. INSTALLER TO ,, SECURE To ROOF STR UCTIME. o r �-- PILLED CHASE BY OTHERS, CHASE TO STOP AT POINT OF CEXNNG PENETRATION I NFPA-41 6 1994 EDITION OR LATER. SECRON 4- ( • s i b PIPE CEILING 10'T ENCLOSURE W/ (1) ((11 2:PTACLES t�tq,NT ) REQUIRES 1 at;DIA 61P INSIDE PLENUM 106,00 5-20%) FACTORY ' TO - lOP OF � BOX (1 (1) 20A RECPTACXE 5--208 FACTORY 10 •t• 104 X4 • H.P. s VOLTS 11.(00" 7.250" FAN WIGHT * LIME. 10 CO1PUN0 FACTORY ono 1� 11000 001.0 110 ON NO00 IS T ED 1 ES l 1 TYPICAL LEFT AND RI I FAN CONNECTION *10" X 10" 71.000" 5 -11" *12" X 12" 9r MOLE HOOD ANSUL FIRE PROTECTION SYSTEM (WET jJQUID SYSTEM) ANSUL FIRE SYSTEM COMPONENTS ARE OPTIONAL BY MARSHALL. LOVER UP 1 16.000' CREASE - TIGHT, CONTINUOUS MELD 3/4" CONDUIT TO HOOD TOP. STACK VELOaTY 3/C •P UNE L 10 SaS TIMER ENCLOSURE F I DUPLEX (1)20A AND MIRED IN TIME ENCLOSURE o� FOR MTG OF N4 BUMP BAR FP 1885 M 1887 FPM N FLIER FAC V ELOCITY • 248 FPM FP 218 M • M•1 mi di ---- ANSUL NWT CHEMICAL SYSIE DAWN 3 DA CYLINDER IN . AUTOMAN TO VIAL.L 1 ENCLOSED MUA PLENUM SUPPLY PLENUM IS A1E FROM E•IAUST IN pp1CONTINUOUSLY CONTINUOUSLY WELDED 'D d/' P05 Hop .4 .4 /L!lNM 0 1 1 &MID eAcx 24.000' • ''► #10-24 X .5' STN STEEL SCREWS OR TACK WELD USED TO SECURE HOOD SIDE FLANGE MAKEUP AIR PLENUM 1 Q s% M. BOTH SIDES 47.000" r aw ON° FACTORY MIRING 4" X 4' ,A11NC11ON BOX FOR RECEPTACLE MIRING HOOD TOP ÷- 688" 1 &250" .438" �a50o" re-- 4.500" 10.000" •• TIMER ENCLOSURE DETAIL HOOD WEIGHT 525 LBS. 460 LBS. REMOTE PULL CAKE UNE J 1 1/2• MECHANICAL 0111 *NM --{ I-- SUIT 1RP DEVICE/FAN OAS UNE O pCAIO I NOT SAM 10 ICAO 10 INTERLOCK w�i�i t ° ��i� " �iiu TO NODE ODE STACK CO M STACK COWER ANGLE HANGER T FACTORY 'D 10 HOOD TOP B01H EXHAUST HOODS ARE ETL US1ED TO CONFORM TO UL 710 SPEW IN ADDITION TO WI_ CER11FIANG ADEQUAlE EXHAUST LEVEL UL ALSO CERTIFIES MATH NFPA 96 C'aONS?RUC110N REQUIREMENTS. THE HOOD IS USED AT 170 CFI PER FOOT OF HOOD MIIMUM. MARSHALL ER. REPORT NO. 552648 HOOD 1 IS MODEL GA- 092 -MUA -1 HOOD 2 IS MODEL CA- 068 -ILIA -1 LO 4 5 10 5 PT A • ABLE FLIER SPACER HOOD EXPLODED ASSEMBLY VIEW 1N NOW 4 IN NOZZLE BREADED TO ROOF ABOVE - SEE DETAIL ALL THREAD ROD B Y OTIE'RS HOOD HANGING DETAIL 1N NOZZLE a1M OM 72" 3/3' PIPE OOIIIECIION HOOD FIRE PROTECTION PIPiNG DETAIL HOODS ARE PREPIPED FROM FACTORY WITH NOZZLES COM NEWT BASED ON STACK O IIG C'N EXHAUST CFM CALCULATIONS CFM CALCUL.ATKII BASED UPON 170 OEM MIL PER LINEAL FT 7.7 LINEAL FT. OF HOOD X170 CFM NM 1309 MINIMUM EXHAUST CFM ACTUAL FAN CFM = 1885 1N AIMED AT CENTER OF mama 40 "SUPPLIED Br SYMBOLS: M - MARSHALL AIR SYSTEMS P - PLUMBER E - ELECTRICIAN H - HVAC CONTRACTOR I - HOOD INSTALLER F - FIRE SYSTEM INSTILLER a� a �as � at NOTE 1. HOOD CONSTRUCTION AND DESIGN MEETS UNIFORM MECHANICAL CODE. Seca, BOCA, IC80 AND NFPA CONSTRUCTION REQUIREMENTS 2, HOOD IS NSF AND UL -710 LISTED. HOOD MODEL GA, ETL REPORT NO. 552648 3. HOOD IS CONSTRUCTED OF 18GA. 300 SERIES STAINLESS STEEL MINIMUM. SEAMS HAVE CONTINUOUS, LIQUID- TIGHT, EXTERNAL WIELD WHERE REQUIRED PER NFPA 96. 4. EXHAUST CFM MINIMUM IS CALCULATED USING 170 CFM PER LINEAR FT OF EXHAUST HOOD PER UL - 710 USTING. 5. ALL INSTALLATION WORK IS TO BE PERFORMED BY QUALIFIED PERSONS AND IN ACCORDANCE WITH STATE AND LOCAL BUILDING CODE REQUIREMENTS. 6. THE INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA -96, REMOVAL OF SMOKE AND GREASE -LADEN VAPORS FROM COMMERCIAL COOKING EQUIPMENT. 7. MATERIAL: HOOD GREASE FILTERS: GREASE FILTERS ARE ONE OF THE FOLLOWING TYPES: (A) FINE GARD, INC., STAINLESS STEEL UL CLASSIFIED FILE # R 6593 TYPE III (B) KASON INC., STAINLESS STEEL UL CLASSIFIED FILE # R 13192 8. HOOD IS PRE -PIPED FOR ANSUL YMET CHEMICAL FIRE SYSTEM. HOOD HAS PIPING DROP CONNECTIONS W/ PLUGS, FOR THE VARIOUS COOKING EQUIPMENT LAYOUTS. A 72" GRIDDLE AND SINGLE VAT FRYER g► 9 36" TOP- SIDED COOKER WITH 36" GRIDDLE AND SINGLE VAT FRYER 9. ALL SUPPLY DUCTWORK AND TRANSITIONS ARE TO BE PROVIDED BY THE HVAC CONTRACTOR. 10. CLEARANCE FROM STACKS TO COMBUSTIBLE MATERIAL SHALL BE PER APPLICABLE BUILDING CODES. 11. FOR PROPER OPERATION OF HOOD SYSTEM, IT IS THE GENERAL CONTRACTOR'S/HVAC CONTRACTOR'S RESPONSIBIUTY TO HAW HOOD TES It1) AND BALANCED TO ENSURE THAT THE EXHAUST CFM LEVEL AND MAKE UP MR CFM LEVEL ARE AT PROPER SETTINGS. IT IS ALSO RECOMMENDED THAT A COMPLETE HVAC MR BALANCE IS PERFORMED. 12. PER THE U1710 LISTING, 2" OF OVERHANG IS REQUIRED FROM THE HOOD SIDES AND THE COOKING SURFACE. MARK 8E BUILDING This druerlog la d1e property of Marelhal Samara% Inc., old contains oonAdantal ore praprMtrry worrneron of IM~ AV *WNW . Thle dr ouhq Is padded to the recipient on loin onyx for pvpesse of rolart#no,• Iodellogeo. two std /or oroM leaner of to depk od eNuyrrhoht of IIershUI At *ism Inc., wd for no other purpose. TMr *ado. 010 not be 1D � & Paid of. or ellanh os •N000rd to any 1hMd pert dwer Away or Indrrolty wroept M oerryMrl out 1M elorsuoid purport% and shell w Nrnned b NerelreM Nr SlfrIsms, , ,Tart. 11* redplat's acceptance of Mb *ado. OW be \ /armed to awrrMnlr apron m ant rod apoontot b the fornpol g tones. SHEET 1 OF 2 INSTILLATION DWG AN-21102 M• • Am= ....m m - • -rte. P P.4 • iy - � Apt? Z6 200 Pflivir 0_004. Merlhe Air *WM Inc. 419 PrJJl4w OArr South � N.C. 2e217 SEE SHEET 401009 (41.1) FOR SHEET 2 OF 2 MARSHALL AIR SYSTEMS, INC. EXH SYS, JACK IN THE BOX GRIDDLE HOOD DETAILS, FIRE PROTECTION SYSTEM 01999 Jade in the Box Inc. These dray/Mgt and aro dm prepowty M .Melt the Mac ire end NW not Ito oepMd er roprottrood without Re provisos er1tan oonennt. TUKWILA, WA DRAWN BY: JW, • SH SCALE: 9330 BALBOA AVENUE SAN 01EG0, CA 92123 3/8' = 1'-0* KITCHEN GRIDDLE HOOD r 4O1698 ; "` r2 011,101 Oa Mee IpOomona ' 4 01 bit. foto , 0 • • • 41 ____ 4r I l e 9 ).© I RECEPTACLE NEMA CIRCUIT SI • 120 • DUPLEX • GRIDDLE =ODLE REV 1 DATE QTY gnome DENIM IIIIIIIII NEI P PINI ART NO. r r MLAUFr�-vr� alEFATratyl SIDE E PANELS 0 0 PAIf1IDE AND INSTALL • 'r �� AID FACTORY nix MOUNTING w n ►a� EtraL HOT 110.E STEEL AND CUT STACK TO LENGTH A FIELD MOD H000 i' FAN EXHAUST FAN CURB MAKEUP AIR SUPPLY FAN ., 1 1 FAN 1n FROM MOTOR STARTERS AID COMPONDITS 10 IIIERLOCK TO SUPPRESSOR Ste. QTY 1 1 1 2 2 1 20 1 1 1 5 AS REQD AS READ AS READ 1 1 1 1 PART NO. 503203 503205 503221 500346 503168 503442 500354 503406 500352 500360 503225 503217 503176 • .. 1 CORNER PULLEY ELBOWS �41J671 CO2 CARTRIDGE FOR AUTOMAN 1s - + :..1 GAS VALVE 1 1/2" MECHANICAL W/ CYUNOER AND TUBING HOOD PREPPING WITH NOZZLES FACTORY INSTALLED IN HOOD DETECTOR BRACKET TERMINAL FACTORY INSTALLED IN HOOD DETECTOR BRACKETS SERIES FACTORY INSTALLED IN HOOD 3/8" B.I.P PIPE, SCH 40 FOR SUPPLY LS 3/8" B.I.P. PIPE FITTINGS FOR SUPPLY LINES 1/2• EMT TUBE FOR DETECTOR UNE INSTALL SYSTEM PIPING AND SYSTEM COMPONENTS INSTALL GAS VALVE AND INTERLOCK TO MIQROSSITC H INSTALL REMOTE MANUAL PUU. AND CONDUIT OUT of TOP OF WALL. LL INSTALL REMOTE PU PROTECTOR SUPPLIED BY: EXHAUST HOOD SYSTEM HOOD w tifif �I1woD Restriat GRIOpLGRIDDLE/FRYER R EXHAUST STACK INSULATION PER LOCAL COOS UNE M 1 1 SUPPLY PL.ENUUM I © ► 17i ;j ]' ry :• .+ 1117 IN HOOD SUPPLY PLENUM %WRING OF ALL RECEPTACLES OF HOOD PLENUM AND 1MER E1NCLS DESCRIPTION DESCRDESCRIPTION � P.w. FIRE PROTECTION SYSTEM HOODS 01 AND 112 GRIDDLE HOOD AND FRYER DESCRIPTION to GALLON ANS>1UL SYSTEM 3.0 GALLON ANSUL AUTOMAN REG. RELEASE ASSEMBLY #79290 3.0 GAL ANSUL CYLINDER W/ MOUNTING BRACKET 3.0 GALLON ANSULEX AGENT /79372 5 DEGREE DETECTOR LINK REMOTE MANUAL PULL REMOTE MANUAL PULL BOX 4" OCTAGONAL RACO #165 DETECTOR CABLE 100 FT. LENGTH ANSUL ELECTRIC SWITCH #32220 4PDT - FIELD INSTALLED dates RELEASE: AUG. 5, 2002 P.U.(JB ONLY} 15 12-31-02 PERMIT: 1/12/04 BID: CONSTRUCTION: 11#; ggil ENgsi ad:I • y ... M Nil! • 0 ete g • r••N O b0 revisions • site information MN( TYPE: CONVERSION .AB # 8365 AD ORE& 3742 S. 144TH STREET - , .r. 7.5 25 . 1 r • ,� t.�M JUNCTION LI SOX FOR HOOD U 4TS POS CHASE a M INFI 10X. HOOD #1 HOOD #2 - v • WRE T / (2 20AMP DUPLEX ACLES (PREMED) 1 CIRCUIT HOOD TO PLENUM AT FLANGES 1W. BOTH SIDES. (3) L6 --13R TMISILOC K RE TACL.ES (PRE MIRED) (3) SEPERA mains FINISHED FLOOR s�1� I REQUcIrt N C�ND n 000 ate DESCRIPTION 4 •41., sreso 3/4" CONDUIT TO HOOD TOP. 0.750' -� it I 92* LOW PROFILE EXHAUST HOOD 68" LOW PROFILE EXHAUST HOOD OEIEK.WIt tat 0500" 2." WNW OVERHANG 101 uLNC •V FR11E:R H000 A 0 oE CION LNC (2) OPEN 1' X 43.500" INSULATION CAVITIES INSULATION OPTIONAL BY MARSHALL DOMED BACK I' s . F ( I k< `?I I, FRONT VIEW � '` -� • ''� ''� �► P. RIGHT SIDE VIEW ,.�, r►. HOOD #1 - 92" GRIDDLE/FRYER 10CENTER OF RECEPTACLES SI I FACTORY G 0 3195 7' -8" 92.000" TOP VIEW 27.000" 15.000" 10.00 4" X 4" JIANCflON BOX FOR RECEPTACLE MIRING HOOD TOP - 11GHT. CONTNIOUS MELD POS CHASE-‘ (2) 20A DUPLEX FACTORY INSTALLED AND MtIRED N TIMER ENCLOSURE � err CONDUIT L;A HOLES L T 1. " FiOR 1 MS AR 43 S MO BUMP BAIL 5,000" 29.875" r TIMER ENCLOSURE DETAIL EXHAUST CFM 1885 1310 VENTILATION SYSTEM INFORMATION MAKEUP AIR 755 525 1280 26.000" 26.000" D L9 ©© MO 0E0 LNC NUMBER FAN MODEL * • * BY OTHERS 3/V SUPPLY TOE 10 HOOD 12.125' X 12.125' EXHAUST OOLLAR FOR 12" X 12" STACK MOO alu STACK NOT PPROb BY B MARSFNAU.� mST 4* X 21' COLLAR TIP• (2) FELD LOCATE AND CU TOP BY INSTALLER 1 1/e GAS LN E CONNECTION 1 EAT CONDUIT /�F'A�CTORY WENDED TO 14ND Ig FOR COMltCIIQN S1 ` 2.250" `3.000 L 2.000" 1.938" FACTORY MEND ED TO 11000 TROP. FOR CONNECTION OF F SYSTEM PANG. JUNCTION BOX FOR TIMER RECEPTACLES, 24" MIRE LEADS IN JUNCTION BOX. HANGER BRACKETS FACTORY MENDED ,.• �• TO HOOD TOP. INSTALLER TO ,, SECURE To ROOF STR UCTIME. o r �-- PILLED CHASE BY OTHERS, CHASE TO STOP AT POINT OF CEXNNG PENETRATION I NFPA-41 6 1994 EDITION OR LATER. SECRON 4- ( • s i b PIPE CEILING 10'T ENCLOSURE W/ (1) ((11 2:PTACLES t�tq,NT ) REQUIRES 1 at;DIA 61P INSIDE PLENUM 106,00 5-20%) FACTORY ' TO - lOP OF � BOX (1 (1) 20A RECPTACXE 5--208 FACTORY 10 •t• 104 X4 • H.P. s VOLTS 11.(00" 7.250" FAN WIGHT * LIME. 10 CO1PUN0 FACTORY ono 1� 11000 001.0 110 ON NO00 IS T ED 1 ES l 1 TYPICAL LEFT AND RI I FAN CONNECTION *10" X 10" 71.000" 5 -11" *12" X 12" 9r MOLE HOOD ANSUL FIRE PROTECTION SYSTEM (WET jJQUID SYSTEM) ANSUL FIRE SYSTEM COMPONENTS ARE OPTIONAL BY MARSHALL. LOVER UP 1 16.000' CREASE - TIGHT, CONTINUOUS MELD 3/4" CONDUIT TO HOOD TOP. STACK VELOaTY 3/C •P UNE L 10 SaS TIMER ENCLOSURE F I DUPLEX (1)20A AND MIRED IN TIME ENCLOSURE o� FOR MTG OF N4 BUMP BAR FP 1885 M 1887 FPM N FLIER FAC V ELOCITY • 248 FPM FP 218 M • M•1 mi di ---- ANSUL NWT CHEMICAL SYSIE DAWN 3 DA CYLINDER IN . AUTOMAN TO VIAL.L 1 ENCLOSED MUA PLENUM SUPPLY PLENUM IS A1E FROM E•IAUST IN pp1CONTINUOUSLY CONTINUOUSLY WELDED 'D d/' P05 Hop .4 .4 /L!lNM 0 1 1 &MID eAcx 24.000' • ''► #10-24 X .5' STN STEEL SCREWS OR TACK WELD USED TO SECURE HOOD SIDE FLANGE MAKEUP AIR PLENUM 1 Q s% M. BOTH SIDES 47.000" r aw ON° FACTORY MIRING 4" X 4' ,A11NC11ON BOX FOR RECEPTACLE MIRING HOOD TOP ÷- 688" 1 &250" .438" �a50o" re-- 4.500" 10.000" •• TIMER ENCLOSURE DETAIL HOOD WEIGHT 525 LBS. 460 LBS. REMOTE PULL CAKE UNE J 1 1/2• MECHANICAL 0111 *NM --{ I-- SUIT 1RP DEVICE/FAN OAS UNE O pCAIO I NOT SAM 10 ICAO 10 INTERLOCK w�i�i t ° ��i� " �iiu TO NODE ODE STACK CO M STACK COWER ANGLE HANGER T FACTORY 'D 10 HOOD TOP B01H EXHAUST HOODS ARE ETL US1ED TO CONFORM TO UL 710 SPEW IN ADDITION TO WI_ CER11FIANG ADEQUAlE EXHAUST LEVEL UL ALSO CERTIFIES MATH NFPA 96 C'aONS?RUC110N REQUIREMENTS. THE HOOD IS USED AT 170 CFI PER FOOT OF HOOD MIIMUM. MARSHALL ER. REPORT NO. 552648 HOOD 1 IS MODEL GA- 092 -MUA -1 HOOD 2 IS MODEL CA- 068 -ILIA -1 LO 4 5 10 5 PT A • ABLE FLIER SPACER HOOD EXPLODED ASSEMBLY VIEW 1N NOW 4 IN NOZZLE BREADED TO ROOF ABOVE - SEE DETAIL ALL THREAD ROD B Y OTIE'RS HOOD HANGING DETAIL 1N NOZZLE a1M OM 72" 3/3' PIPE OOIIIECIION HOOD FIRE PROTECTION PIPiNG DETAIL HOODS ARE PREPIPED FROM FACTORY WITH NOZZLES COM NEWT BASED ON STACK O IIG C'N EXHAUST CFM CALCULATIONS CFM CALCUL.ATKII BASED UPON 170 OEM MIL PER LINEAL FT 7.7 LINEAL FT. OF HOOD X170 CFM NM 1309 MINIMUM EXHAUST CFM ACTUAL FAN CFM = 1885 1N AIMED AT CENTER OF mama 40 "SUPPLIED Br SYMBOLS: M - MARSHALL AIR SYSTEMS P - PLUMBER E - ELECTRICIAN H - HVAC CONTRACTOR I - HOOD INSTALLER F - FIRE SYSTEM INSTILLER a� a �as � at NOTE 1. HOOD CONSTRUCTION AND DESIGN MEETS UNIFORM MECHANICAL CODE. Seca, BOCA, IC80 AND NFPA CONSTRUCTION REQUIREMENTS 2, HOOD IS NSF AND UL -710 LISTED. HOOD MODEL GA, ETL REPORT NO. 552648 3. HOOD IS CONSTRUCTED OF 18GA. 300 SERIES STAINLESS STEEL MINIMUM. SEAMS HAVE CONTINUOUS, LIQUID- TIGHT, EXTERNAL WIELD WHERE REQUIRED PER NFPA 96. 4. EXHAUST CFM MINIMUM IS CALCULATED USING 170 CFM PER LINEAR FT OF EXHAUST HOOD PER UL - 710 USTING. 5. ALL INSTALLATION WORK IS TO BE PERFORMED BY QUALIFIED PERSONS AND IN ACCORDANCE WITH STATE AND LOCAL BUILDING CODE REQUIREMENTS. 6. THE INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA -96, REMOVAL OF SMOKE AND GREASE -LADEN VAPORS FROM COMMERCIAL COOKING EQUIPMENT. 7. MATERIAL: HOOD GREASE FILTERS: GREASE FILTERS ARE ONE OF THE FOLLOWING TYPES: (A) FINE GARD, INC., STAINLESS STEEL UL CLASSIFIED FILE # R 6593 TYPE III (B) KASON INC., STAINLESS STEEL UL CLASSIFIED FILE # R 13192 8. HOOD IS PRE -PIPED FOR ANSUL YMET CHEMICAL FIRE SYSTEM. HOOD HAS PIPING DROP CONNECTIONS W/ PLUGS, FOR THE VARIOUS COOKING EQUIPMENT LAYOUTS. A 72" GRIDDLE AND SINGLE VAT FRYER g► 9 36" TOP- SIDED COOKER WITH 36" GRIDDLE AND SINGLE VAT FRYER 9. ALL SUPPLY DUCTWORK AND TRANSITIONS ARE TO BE PROVIDED BY THE HVAC CONTRACTOR. 10. CLEARANCE FROM STACKS TO COMBUSTIBLE MATERIAL SHALL BE PER APPLICABLE BUILDING CODES. 11. FOR PROPER OPERATION OF HOOD SYSTEM, IT IS THE GENERAL CONTRACTOR'S/HVAC CONTRACTOR'S RESPONSIBIUTY TO HAW HOOD TES It1) AND BALANCED TO ENSURE THAT THE EXHAUST CFM LEVEL AND MAKE UP MR CFM LEVEL ARE AT PROPER SETTINGS. IT IS ALSO RECOMMENDED THAT A COMPLETE HVAC MR BALANCE IS PERFORMED. 12. PER THE U1710 LISTING, 2" OF OVERHANG IS REQUIRED FROM THE HOOD SIDES AND THE COOKING SURFACE. MARK 8E BUILDING This druerlog la d1e property of Marelhal Samara% Inc., old contains oonAdantal ore praprMtrry worrneron of IM~ AV *WNW . Thle dr ouhq Is padded to the recipient on loin onyx for pvpesse of rolart#no,• Iodellogeo. two std /or oroM leaner of to depk od eNuyrrhoht of IIershUI At *ism Inc., wd for no other purpose. TMr *ado. 010 not be 1D � & Paid of. or ellanh os •N000rd to any 1hMd pert dwer Away or Indrrolty wroept M oerryMrl out 1M elorsuoid purport% and shell w Nrnned b NerelreM Nr SlfrIsms, , ,Tart. 11* redplat's acceptance of Mb *ado. OW be \ /armed to awrrMnlr apron m ant rod apoontot b the fornpol g tones. SHEET 1 OF 2 INSTILLATION DWG AN-21102 M• • Am= ....m m - • -rte. P P.4 • iy - � Apt? Z6 200 Pflivir 0_004. Merlhe Air *WM Inc. 419 PrJJl4w OArr South � N.C. 2e217 SEE SHEET 401009 (41.1) FOR SHEET 2 OF 2 MARSHALL AIR SYSTEMS, INC. EXH SYS, JACK IN THE BOX GRIDDLE HOOD DETAILS, FIRE PROTECTION SYSTEM 01999 Jade in the Box Inc. These dray/Mgt and aro dm prepowty M .Melt the Mac ire end NW not Ito oepMd er roprottrood without Re provisos er1tan oonennt. TUKWILA, WA DRAWN BY: JW, • SH SCALE: 9330 BALBOA AVENUE SAN 01EG0, CA 92123 3/8' = 1'-0* KITCHEN GRIDDLE HOOD r 4O1698 ; "` r2 011,101 Oa Mee IpOomona ' 4 01 bit. foto , 0 • • • 41 HOOD ELECTRICAL LEGEND OUTLET # MIRE SIZE VOLTAGE AMPS RECEPTACLE NEMA CIRCUIT SI 12 120 20 DUPLEX 5-20R B-9 I_ 11 la 4 II 12 20 DUPLEX NC 8-20 12 20 DUPLEX 8-9 12 15 -__- SIMPLEX A -26, 28 y 1 2 12 r 15 ' SIMPLEX A -30, 32 1 15 SIMPLEX A -34, 36 12 20 DUPLEX 8-9 1 2 120 20 DUPLEX Er20R 8-9 !I 12 120 DUPLEX 5 -20R B -9 H000 Lx6i?S 12 120 .- - C -39 • GRIDDLE =ODLE REV 1 DATE QTY gnome DENIM IIIIIIIII NEI P PINI ART NO. r r MLAUFr�-vr� alEFATratyl SIDE E PANELS 0 0 PAIf1IDE AND INSTALL • 'r �� AID FACTORY nix MOUNTING w n ►a� EtraL HOT 110.E STEEL AND CUT STACK TO LENGTH A FIELD MOD H000 i' FAN EXHAUST FAN CURB MAKEUP AIR SUPPLY FAN ., 1 1 FAN 1n FROM MOTOR STARTERS AID COMPONDITS 10 IIIERLOCK TO SUPPRESSOR Ste. QTY 1 1 1 2 2 1 20 1 1 1 5 AS REQD AS READ AS READ 1 1 1 1 PART NO. 503203 503205 503221 500346 503168 503442 500354 503406 500352 500360 503225 503217 503176 • .. 1 CORNER PULLEY ELBOWS �41J671 CO2 CARTRIDGE FOR AUTOMAN 1s - + :..1 GAS VALVE 1 1/2" MECHANICAL W/ CYUNOER AND TUBING HOOD PREPPING WITH NOZZLES FACTORY INSTALLED IN HOOD DETECTOR BRACKET TERMINAL FACTORY INSTALLED IN HOOD DETECTOR BRACKETS SERIES FACTORY INSTALLED IN HOOD 3/8" B.I.P PIPE, SCH 40 FOR SUPPLY LS 3/8" B.I.P. PIPE FITTINGS FOR SUPPLY LINES 1/2• EMT TUBE FOR DETECTOR UNE INSTALL SYSTEM PIPING AND SYSTEM COMPONENTS INSTALL GAS VALVE AND INTERLOCK TO MIQROSSITC H INSTALL REMOTE MANUAL PUU. AND CONDUIT OUT of TOP OF WALL. LL INSTALL REMOTE PU PROTECTOR SUPPLIED BY: EXHAUST HOOD SYSTEM HOOD w tifif �I1woD Restriat GRIOpLGRIDDLE/FRYER R EXHAUST STACK INSULATION PER LOCAL COOS UNE M 1 1 SUPPLY PL.ENUUM I © ► 17i ;j ]' ry :• .+ 1117 IN HOOD SUPPLY PLENUM %WRING OF ALL RECEPTACLES OF HOOD PLENUM AND 1MER E1NCLS DESCRIPTION DESCRDESCRIPTION � P.w. FIRE PROTECTION SYSTEM HOODS 01 AND 112 GRIDDLE HOOD AND FRYER DESCRIPTION to GALLON ANS>1UL SYSTEM 3.0 GALLON ANSUL AUTOMAN REG. RELEASE ASSEMBLY #79290 3.0 GAL ANSUL CYLINDER W/ MOUNTING BRACKET 3.0 GALLON ANSULEX AGENT /79372 5 DEGREE DETECTOR LINK REMOTE MANUAL PULL REMOTE MANUAL PULL BOX 4" OCTAGONAL RACO #165 DETECTOR CABLE 100 FT. LENGTH ANSUL ELECTRIC SWITCH #32220 4PDT - FIELD INSTALLED dates RELEASE: AUG. 5, 2002 P.U.(JB ONLY} 15 12-31-02 PERMIT: 1/12/04 BID: CONSTRUCTION: 11#; ggil ENgsi ad:I • y ... M Nil! • 0 ete g • r••N O b0 revisions • site information MN( TYPE: CONVERSION .AB # 8365 AD ORE& 3742 S. 144TH STREET - , .r. 7.5 25 . 1 r • ,� t.�M JUNCTION LI SOX FOR HOOD U 4TS POS CHASE a M INFI 10X. HOOD #1 HOOD #2 - v • WRE T / (2 20AMP DUPLEX ACLES (PREMED) 1 CIRCUIT HOOD TO PLENUM AT FLANGES 1W. BOTH SIDES. (3) L6 --13R TMISILOC K RE TACL.ES (PRE MIRED) (3) SEPERA mains FINISHED FLOOR s�1� I REQUcIrt N C�ND n 000 ate DESCRIPTION 4 •41., sreso 3/4" CONDUIT TO HOOD TOP. 0.750' -� it I 92* LOW PROFILE EXHAUST HOOD 68" LOW PROFILE EXHAUST HOOD OEIEK.WIt tat 0500" 2." WNW OVERHANG 101 uLNC •V FR11E:R H000 A 0 oE CION LNC (2) OPEN 1' X 43.500" INSULATION CAVITIES INSULATION OPTIONAL BY MARSHALL DOMED BACK I' s . F ( I k< `?I I, FRONT VIEW � '` -� • ''� ''� �► P. RIGHT SIDE VIEW ,.�, r►. HOOD #1 - 92" GRIDDLE/FRYER 10CENTER OF RECEPTACLES SI I FACTORY G 0 3195 7' -8" 92.000" TOP VIEW 27.000" 15.000" 10.00 4" X 4" JIANCflON BOX FOR RECEPTACLE MIRING HOOD TOP - 11GHT. CONTNIOUS MELD POS CHASE-‘ (2) 20A DUPLEX FACTORY INSTALLED AND MtIRED N TIMER ENCLOSURE � err CONDUIT L;A HOLES L T 1. " FiOR 1 MS AR 43 S MO BUMP BAIL 5,000" 29.875" r TIMER ENCLOSURE DETAIL EXHAUST CFM 1885 1310 VENTILATION SYSTEM INFORMATION MAKEUP AIR 755 525 1280 26.000" 26.000" D L9 ©© MO 0E0 LNC NUMBER FAN MODEL * • * BY OTHERS 3/V SUPPLY TOE 10 HOOD 12.125' X 12.125' EXHAUST OOLLAR FOR 12" X 12" STACK MOO alu STACK NOT PPROb BY B MARSFNAU.� mST 4* X 21' COLLAR TIP• (2) FELD LOCATE AND CU TOP BY INSTALLER 1 1/e GAS LN E CONNECTION 1 EAT CONDUIT /�F'A�CTORY WENDED TO 14ND Ig FOR COMltCIIQN S1 ` 2.250" `3.000 L 2.000" 1.938" FACTORY MEND ED TO 11000 TROP. FOR CONNECTION OF F SYSTEM PANG. JUNCTION BOX FOR TIMER RECEPTACLES, 24" MIRE LEADS IN JUNCTION BOX. HANGER BRACKETS FACTORY MENDED ,.• �• TO HOOD TOP. INSTALLER TO ,, SECURE To ROOF STR UCTIME. o r �-- PILLED CHASE BY OTHERS, CHASE TO STOP AT POINT OF CEXNNG PENETRATION I NFPA-41 6 1994 EDITION OR LATER. SECRON 4- ( • s i b PIPE CEILING 10'T ENCLOSURE W/ (1) ((11 2:PTACLES t�tq,NT ) REQUIRES 1 at;DIA 61P INSIDE PLENUM 106,00 5-20%) FACTORY ' TO - lOP OF � BOX (1 (1) 20A RECPTACXE 5--208 FACTORY 10 •t• 104 X4 • H.P. s VOLTS 11.(00" 7.250" FAN WIGHT * LIME. 10 CO1PUN0 FACTORY ono 1� 11000 001.0 110 ON NO00 IS T ED 1 ES l 1 TYPICAL LEFT AND RI I FAN CONNECTION *10" X 10" 71.000" 5 -11" *12" X 12" 9r MOLE HOOD ANSUL FIRE PROTECTION SYSTEM (WET jJQUID SYSTEM) ANSUL FIRE SYSTEM COMPONENTS ARE OPTIONAL BY MARSHALL. LOVER UP 1 16.000' CREASE - TIGHT, CONTINUOUS MELD 3/4" CONDUIT TO HOOD TOP. STACK VELOaTY 3/C •P UNE L 10 SaS TIMER ENCLOSURE F I DUPLEX (1)20A AND MIRED IN TIME ENCLOSURE o� FOR MTG OF N4 BUMP BAR FP 1885 M 1887 FPM N FLIER FAC V ELOCITY • 248 FPM FP 218 M • M•1 mi di ---- ANSUL NWT CHEMICAL SYSIE DAWN 3 DA CYLINDER IN . AUTOMAN TO VIAL.L 1 ENCLOSED MUA PLENUM SUPPLY PLENUM IS A1E FROM E•IAUST IN pp1CONTINUOUSLY CONTINUOUSLY WELDED 'D d/' P05 Hop .4 .4 /L!lNM 0 1 1 &MID eAcx 24.000' • ''► #10-24 X .5' STN STEEL SCREWS OR TACK WELD USED TO SECURE HOOD SIDE FLANGE MAKEUP AIR PLENUM 1 Q s% M. BOTH SIDES 47.000" r aw ON° FACTORY MIRING 4" X 4' ,A11NC11ON BOX FOR RECEPTACLE MIRING HOOD TOP ÷- 688" 1 &250" .438" �a50o" re-- 4.500" 10.000" •• TIMER ENCLOSURE DETAIL HOOD WEIGHT 525 LBS. 460 LBS. REMOTE PULL CAKE UNE J 1 1/2• MECHANICAL 0111 *NM --{ I-- SUIT 1RP DEVICE/FAN OAS UNE O pCAIO I NOT SAM 10 ICAO 10 INTERLOCK w�i�i t ° ��i� " �iiu TO NODE ODE STACK CO M STACK COWER ANGLE HANGER T FACTORY 'D 10 HOOD TOP B01H EXHAUST HOODS ARE ETL US1ED TO CONFORM TO UL 710 SPEW IN ADDITION TO WI_ CER11FIANG ADEQUAlE EXHAUST LEVEL UL ALSO CERTIFIES MATH NFPA 96 C'aONS?RUC110N REQUIREMENTS. THE HOOD IS USED AT 170 CFI PER FOOT OF HOOD MIIMUM. MARSHALL ER. REPORT NO. 552648 HOOD 1 IS MODEL GA- 092 -MUA -1 HOOD 2 IS MODEL CA- 068 -ILIA -1 LO 4 5 10 5 PT A • ABLE FLIER SPACER HOOD EXPLODED ASSEMBLY VIEW 1N NOW 4 IN NOZZLE BREADED TO ROOF ABOVE - SEE DETAIL ALL THREAD ROD B Y OTIE'RS HOOD HANGING DETAIL 1N NOZZLE a1M OM 72" 3/3' PIPE OOIIIECIION HOOD FIRE PROTECTION PIPiNG DETAIL HOODS ARE PREPIPED FROM FACTORY WITH NOZZLES COM NEWT BASED ON STACK O IIG C'N EXHAUST CFM CALCULATIONS CFM CALCUL.ATKII BASED UPON 170 OEM MIL PER LINEAL FT 7.7 LINEAL FT. OF HOOD X170 CFM NM 1309 MINIMUM EXHAUST CFM ACTUAL FAN CFM = 1885 1N AIMED AT CENTER OF mama 40 "SUPPLIED Br SYMBOLS: M - MARSHALL AIR SYSTEMS P - PLUMBER E - ELECTRICIAN H - HVAC CONTRACTOR I - HOOD INSTALLER F - FIRE SYSTEM INSTILLER a� a �as � at NOTE 1. HOOD CONSTRUCTION AND DESIGN MEETS UNIFORM MECHANICAL CODE. Seca, BOCA, IC80 AND NFPA CONSTRUCTION REQUIREMENTS 2, HOOD IS NSF AND UL -710 LISTED. HOOD MODEL GA, ETL REPORT NO. 552648 3. HOOD IS CONSTRUCTED OF 18GA. 300 SERIES STAINLESS STEEL MINIMUM. SEAMS HAVE CONTINUOUS, LIQUID- TIGHT, EXTERNAL WIELD WHERE REQUIRED PER NFPA 96. 4. EXHAUST CFM MINIMUM IS CALCULATED USING 170 CFM PER LINEAR FT OF EXHAUST HOOD PER UL - 710 USTING. 5. ALL INSTALLATION WORK IS TO BE PERFORMED BY QUALIFIED PERSONS AND IN ACCORDANCE WITH STATE AND LOCAL BUILDING CODE REQUIREMENTS. 6. THE INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA -96, REMOVAL OF SMOKE AND GREASE -LADEN VAPORS FROM COMMERCIAL COOKING EQUIPMENT. 7. MATERIAL: HOOD GREASE FILTERS: GREASE FILTERS ARE ONE OF THE FOLLOWING TYPES: (A) FINE GARD, INC., STAINLESS STEEL UL CLASSIFIED FILE # R 6593 TYPE III (B) KASON INC., STAINLESS STEEL UL CLASSIFIED FILE # R 13192 8. HOOD IS PRE -PIPED FOR ANSUL YMET CHEMICAL FIRE SYSTEM. HOOD HAS PIPING DROP CONNECTIONS W/ PLUGS, FOR THE VARIOUS COOKING EQUIPMENT LAYOUTS. A 72" GRIDDLE AND SINGLE VAT FRYER g► 9 36" TOP- SIDED COOKER WITH 36" GRIDDLE AND SINGLE VAT FRYER 9. ALL SUPPLY DUCTWORK AND TRANSITIONS ARE TO BE PROVIDED BY THE HVAC CONTRACTOR. 10. CLEARANCE FROM STACKS TO COMBUSTIBLE MATERIAL SHALL BE PER APPLICABLE BUILDING CODES. 11. FOR PROPER OPERATION OF HOOD SYSTEM, IT IS THE GENERAL CONTRACTOR'S/HVAC CONTRACTOR'S RESPONSIBIUTY TO HAW HOOD TES It1) AND BALANCED TO ENSURE THAT THE EXHAUST CFM LEVEL AND MAKE UP MR CFM LEVEL ARE AT PROPER SETTINGS. IT IS ALSO RECOMMENDED THAT A COMPLETE HVAC MR BALANCE IS PERFORMED. 12. PER THE U1710 LISTING, 2" OF OVERHANG IS REQUIRED FROM THE HOOD SIDES AND THE COOKING SURFACE. MARK 8E BUILDING This druerlog la d1e property of Marelhal Samara% Inc., old contains oonAdantal ore praprMtrry worrneron of IM~ AV *WNW . Thle dr ouhq Is padded to the recipient on loin onyx for pvpesse of rolart#no,• Iodellogeo. two std /or oroM leaner of to depk od eNuyrrhoht of IIershUI At *ism Inc., wd for no other purpose. TMr *ado. 010 not be 1D � & Paid of. or ellanh os •N000rd to any 1hMd pert dwer Away or Indrrolty wroept M oerryMrl out 1M elorsuoid purport% and shell w Nrnned b NerelreM Nr SlfrIsms, , ,Tart. 11* redplat's acceptance of Mb *ado. OW be \ /armed to awrrMnlr apron m ant rod apoontot b the fornpol g tones. SHEET 1 OF 2 INSTILLATION DWG AN-21102 M• • Am= ....m m - • -rte. P P.4 • iy - � Apt? Z6 200 Pflivir 0_004. Merlhe Air *WM Inc. 419 PrJJl4w OArr South � N.C. 2e217 SEE SHEET 401009 (41.1) FOR SHEET 2 OF 2 MARSHALL AIR SYSTEMS, INC. EXH SYS, JACK IN THE BOX GRIDDLE HOOD DETAILS, FIRE PROTECTION SYSTEM 01999 Jade in the Box Inc. These dray/Mgt and aro dm prepowty M .Melt the Mac ire end NW not Ito oepMd er roprottrood without Re provisos er1tan oonennt. TUKWILA, WA DRAWN BY: JW, • SH SCALE: 9330 BALBOA AVENUE SAN 01EG0, CA 92123 3/8' = 1'-0* KITCHEN GRIDDLE HOOD r 4O1698 ; "` r2 011,101 Oa Mee IpOomona ' 4 01 bit. foto , 0 • • • 41 I ,, DEPARTMCNT 9330 BALBOA AVENUE SAN DEGO, CA 92123 01999 Jock in the Box Inc. Thaw drawing. and wooeilioatiens =turret M*tes:I: them I l l Ir a: without its one*Ioue written oaneewt. dotes RELEASE: AUG. 5, 2002 P.U.(JAB ONLY): • 12-31-02 PERMIT: 1/12/04 DD: CONSTRUCTION: revisions MIL • ELECTRICAL IN ArEoa NI, eRaM 15) mi-atit FAL (426) hner.te.eoa.ln.00m IT & S INC site information MK TYPE: CONVERSION &It 8365 ADDRESS: 3742 S. 144TH STREET . TUK WILA, WA DRAWN BY: kW, NN, SH SCALE: AS NOTED KITCHEN FRYER HOOD 1 1 el • HOOD #1 HOOD #2 92" LOW PROFILE EXHAUST HOOD 68' LOW PROFILE EXHAUST HOOD TOTAL 1885 1310 3195 755 525 1280 * * * •12' x 12" *10" 1885 FPM 1887 FPM 248 FPM 218 FPM .4 .4 525 LBS. 460 LBS. * BY OTHERS MEd 1. HOOD CONSTRUCTION AND DESIGN MEETS UNIFORM MECHANICAL CODE, SBca, BOCA, ICBO AND NFPA CONSTRUCTION REQUIREMENTS 2. HOOD IS NSF AND UL-710 USTED. HOOD MODEL GA, ETL REPORT NO. 552648 3. HOOD IS CONSTRUCTED OF 18GA. 300 SERIES STAINLESS STEEL MINIMUM. SEAMS HAVE CONTINUOUS, UQU ID- TIGHT, EXTERNAL WELD WHERE REQUIRED PER NFPA 96. 4. EXHAUST CFM MINIMUM IS CALCULATED USING 170 CFM PER LINEAR FT OF EXHAUST HOOD PER UL USTING. 5. ALL INSTALLATION WORK IS TO BE PERFORMED BY QUALIFIED PERSONS AND IN ACCORDANCE WITH STATE AND LOCAL BUILDING CODE REQUIREMENTS. 6. THE INSTALLATION SHALT, BE IN ACCORDANCE WITH NFPA-96, REMOVAL OF SMOKE AND GREASE -LADEN VAPORS FROM COMMERCIAL COOKING EQUIPMENT. 7. MATERIAL: HOOD GREASE ALTERS: GREASE ALTERS ARE ONE OF THE FOLLOWING TYPES: (A) FLAME GARD, INC., STAINLESS STEEL TYPE III UL CLASSIFIED FILE # R 6593 (B) KASON INC., STAINLESS STEEL UL CLASSIFIED FILE # R 13192 8. HOOD IS PRE -PIPED FOR ANSUL WET CHEMICAL FIRE SYSTEM. 9. ALL SUPPLY DUCTWORK AND TRANSITIONS ARE TO BE PROVIDED BY THE HVAC CONTRACTOR. 10. CLEARANCE FROM STACKS TO COMBUSTIBLE MATERIAL SHALL BE PER APPLICABLE BUILDING CODES. 11. FOR PROPER OPERATION OF HOOD SYSTEM, IT IS THE GENERAL CONTRACTOR'S/HVAC CONTRACTOR'S RESPONSIBILITY TO HAVE HOOD TESTED AND BALANCED TO ENSURE THAT THE EXHAUST CFM LEVEL AND MAKE UP AIR CFM LEVEL ARE AT PROPER SETTINGS. IT IS ALSO RECOMMENDED THAT A COMPLETE HVAC AIR BALANCE IS PERFORMED. 12. PER THE U1710 USTING, 2" OF OVERHANG IS REQUIRED FROM THE HOOD SIDES AND THE COOKING SURFACE. PART IMO. ti 'GA. HOT BOLL S1EE1. an STACK TO LENGTH AND FELD MELD MAKEUP MR SUPPLY FAN MAKEUP AR DUCTWORIC FROM FAN TO HOODS. MOTOR STARTERS MID COMPONENTS TO INTERLOCK ME SUPPRESION SYS. 1 1 1 2 6 1 1 2 1 20 1 1 1 5 503203 503205 503221 500346 503168 503225 503217 503176 . . 6.0 o GALLON ANUL aa �u� srsiar 111' � oQ� DETECTOR TOR ui«c REIJOIE 'MANUAL MANUAL PULL 30 GALLON AWL AUTOMAN REG. RELEASE ASEMBY X79290 3.0 GAL ANUL CYU�NDER W/ MOUNTING BRA I T 30 GALLON ANSULEX AGENT 79372 503442 500354 503406 500352 CO2 CARTRIDGE FOR AUTOMAN 1. - . REMOTE MANUAL PULL BOX 4' OCTAGONAL. RACO /165 DETECTOR CABLE #79653 100 FT. LENGTH ANSUL ELECTRIC STCH 4PDT - FIELD INSTALLED COER PULLEY ELBO15671 GAS VALVE 1 1 /2" InECHAN ICAL W/ CYLNDER AND TUBING HOOD PREPIPNG WITH NOZZLES FACTORY INSTALLED N HOOD DETECTOR BRACKET TERMINAL FACTORY INSTALLED ALLED MI HOOD DETECTOR BRA(ETS SERBS FACTORY INSTALLED ALLED N HOOD if I l I, 1 Fa° 'T •r'• • 1P; (2) 1 3GAS UNE COISEC1I X W COLLAR T1". ap LOCATE AID CUT N TOP BY INST PO6 CHASE ONG JUNCTION BOX FOR TIER RECEPTACLES. 24' VI RE LEADS N JUNCTION BOX. JUNCTION BOX FOR HOOD UGN1$ 2 PL�CS. LIGHTS SIPPUED NTH C' LEAD MIRES N JUNCTION BOX. HANGER BRACKETS FACTORY MELDED TO HOOD TOP. INSTALLER ALLER TO CURE TO ROOF STRUCTU TIMER ENCLOSURE I R i)zoA G ND O DESCRIPTION 6O"" FER HOOD 4' X 4" JUNCTION BOX FOR DUPLEX RECEPTA JES 1a125' X /Q125 ; 1 ! %r J STAu c COER 7.625" MEN ER FACTORY NSTAU.ED N HOOD. SEE BNURE DETAIL (1) 20A RCUIT REQUED 1 1 / 4 DIA BIP ROUTED 106.000" RISME BAKWALL t 7' -10 t I HOOD SECURD TO BCIMLI n . BON SIDES. AT FLANGES (2) 20A DUPLEX RECFPT 1M R AI E5' (5 -20R) FACTORY ED TO TOP OF HOOD TO 4" X 4" JUNCTION BOX FINISHED FIED 1 1 /4' DIA BIP ELBOW It � ♦, 3/4" CONDUIT TO HOOD TOP. 0.750" p 6.000" 0.500" 300 OEC 1I 800 OM t U • 11 MI FACTORY RING (2) 20A DUPLEX ACTORY INSTALLS) ALLED MIMR AND ED N 1IER S E T CFM HOOD 10P 1/2" CONDUIT TOP VIEW .. .. .. do v • '" v► V MAKEUP AIR 68.000" 5 , - 51.000" 11 Il II 11 1111 H 4" X 4" JUNCTION BOX FOR CEPTACLE %MNG - TIGHT. CONTINUOUS NTINUOUS MELD 68.000 CH J POS ASE 0 --\ E � TIMER ENCLOSURE DETAIL 250" DIA HOLES FOR MT� ES AN8.000" 29.875" 3/13 /E MOD , S PPLY L 70 0MOD WW1= LW L .� HOOT 1 � M i " A G? 17.000' 1 TO GEN TER REEPTACLES 2 EVRIt IAN 1 /T' EMT CONDUIT FACTORY VAUD To 1NODD TP FOR COIIECTION OF FHw am 11EM DETDETECTOR U E ir 1-2.000" 000• 3/d" FACTORY TO HOOD TOP. FOR OF FIRE STEM PIPINGJ %s FILTERS MM-RATED CHAE BY OTHES, t (4) 16" X 18' I J CHASE TO STOP AT POINT OF C NG PENETRATION I ADJUSTABLE EATER SPACER SECTION i-iS Mg EDITION oR LATER. «n �Y nnn AQ! I r .1 '1 VENTILATION SYSTEM INFORMATION i HOOD #2 - FRYER HOOD FAN MODEL NUMBER H.P. VOLTS AN WEIGHT WEIGHT LOR LG 71.000 -11" 16.000" r �, % ..• 4 2.250" 3.000 7.250" MOR ono 7 INQ MN NW INMAN I�CTION or GRIDDLE HOW c A._ N2JL FlRE PROTECTI S YS u (�Q��D SYSTEM) ANSUL FIRE SYS?EM COMPONENTS ARE pP71pNAL BY MARSHALL 0 STACK COVER I HT BAD ON 7'- CEILING CEILING STACK VELOCITY '" !"AIM LY LIE FILTER FAE VELOCITY 4.500" L � M& MET OEMCAL SYSTE3 GLON MER N WL AUIONAN MTED TO RILL OFFSET BY OTHERS EN OSED MUA PLENUM 1 F l a L T N E PLENUM iINU�OU ° WELDE L EXHUST H MAKE UP AR DIIHAR 1/4' GAS PPE " MA UP AMR 24.000 KE B � w � lab ar I.. * aft 111 BOTH EXHAUST HOODS ARE EU. LISTED TO CONFORM TO UL 710 SPECS. IN ADDITION TO C R1FYNiG ADEQUATE EXHAUST LEVELS. UL ALSO ® CCERTIFIES COMPUANC NTH NFPA 96 CONSTRUCTION QLIDENTS. THE HOOD IS USTED AT 170 CFM PER FOOT OF HOOD MINIMUM. MARSHALL ETL REPORT NO. 552648 HOOD 1 IS MODEL GA- 092 -MUA -1 HOOD 2 IS MODEL GA- 068 -MUA -1 EXHAUST am CALCULATIONS CFM CLCULATION BAED UPON 170 CEM MIN. PER LINEAL FT OF HOOD 5.7 UIEAL Ft OF HOOD X 170 CFM 969 INNNM M EEXHST CFM ACTUAL FAN CFM = 1310 ACCESS PANEL. 00R 14 4. )l e r' r I 1 I I HOOD WEIGHT REMOTE PULL CABLE LNE 1 1 I 1 1 1/2" MECHANICAL O LIE O -I GAS aCAlI s NOR i1 ELECTCAL CIRC UT 10 MICROSTCH TO SHUNT TRIP DEVDEVICE/FAN N1EOOC �M TO E STACK OMR M LOCA 45 ' s T Aw1E R M PILL EASON t TO ROOF ABOVE - SEE THREADED RCO SECURE or� e/o ALL THREAD ROD BY OTHERS HANR BRAIET FACTORY LDED TO HOOD TOP M" W HOOD Y11 SACK1W1LL TOP. 5, �� s 1 aGREASE nsE air wow door HOOD HANGING DETAIL (4) 230 NOZZLES f n'I t" A'�"I A' 111114 aa� 910 910 X .5' STN STEEL REWS UD TO SECUWEAN FLANGE St LL TIP. BOTH KS. H0FIRE PROTCTION PIPING DETAIL HOODS ARE pREpIpEp FRpM FACTORY MATH NO2ZLES REMOTE PULL FOR BOTH HOODS 5'-d" A.F.F. BELOW ANSUL TANK FRER HOOD EXHAU8T HOOD 8Y8TEM HOOD C FRYER HOOD DESCRIPTION DESCRIPTION C SUPPLIED BY" SYMBOLS: M - MARSHALL Alt SYSTEMS N 0 _ - OER P E - ELEgAW H - HVAC CONTRACTOR I - HOOD INSTALLER F - FItE SYSTEM INSTALLER ALLER SEE K- SHEETS FOR LOCATIONS Ea® S PIPING BY PLU. CON1R �o,ADJAENT m WLK-INS �WLK-INS s c�uaw .ka, cvc,ru 6 GALLON ANSUL SYSTEM FOR BOTH HOODS ERIFY LOCATION N FLLD n E FIRE PROTECTION SYSTEM HOODS /1 AND $2 GRIDDLE HOOD AND FRYER QTY PART NO. DESCRIPTION 3/8' B.I.P PIPE, SCH 40 FOR SUPPLY LINES 3/8' B.LP. PIPE FITTINGS FOR SUPPLY UNES 1/2" EMT TUBE FOR DETECTOR LINE INSTALL SYSTEM PIPING AND SYSTEM COMPONENTS INSTALL GAS VALVE AND INTERLOCK TO MICROSMATCH INSTALL REMOTE MANUAL PULL CONDUIT OUT OF INSTALL REMOTE PULL PROTECTOR FIRE EXTINGUISHER (40 B.C.) BY JACK N THE BOX, NC, r 1/2" MECH. GAS VALVE PROVIDED PLUMBI DG B CO M. INSTALLED BY KITCHEN PLAN VIEW STANDARD EQUIPMENT LAYOUT SHOWN REVERSE EQUIPMENT LAYOUT OPPOSITE SHOWN GNOME HOOD now" -I r-er MARK 8E BUILDING This dooaNn9 w the proP.tr of NsrilhdH Air SpIONtik Cru captains canNentid and PFMNIMary billormetke at MuW i Air Wane, INC. *dB ageing is provided b Se rodpirrit on kw clay for pompous Non d MIr At et Rheims, iM1�MwR ewe eed /er n eht ismoe of the &Oct l Spline, • wed ter No erne, purpose. ThM dr 614 Ski l not be _A rnprodwid. Iowoa, *Pend oA or erneretee dlr doped b any MN PAX dew w &weft er ip*scIy swept In coning set Ire etereeoM purpor*r, and shpt '* niblimed b Manlike Air *plum Inc,, upon relrwt. TNne r H'e ecospbenoe d P *sag shill be destined ID meek* arm Cowin! end e•swlnent to Me MMfOMn9 tem. REV DATE i :� -.�P- DESCRIPTION ::=?:N � UM P. W. 26•- JUN -2002 SHEET 2OF2 INSTALLATION DWG ,+. . eimm - w•. MINIM AMIN. rrmtr MARSHALL AIR SYSTEMS, INC. EXH SYS, JACK IN THE BOX FRYER HOOD HOOD DETAILS, FIRE PROTECTION SYSTEM 3 19" - l'- Asir( f""" 401699 n r cwesm caav t ' GOr 0' J STANDARD EQPT. SEE SET 401606 0111.0) FOR SNEET 1 Cr 2 REVEIRS'E EQPT. RE MT 401700 FOR A#ET 1 OF 2 • r'ny n,� r �0 APR 2 6 2004 Marehdl Ak System tic. 419 Peachtree Cities South Charlotte, N.C. 28217 (7p 525 OIPpyrt IN mood at flown -, Mw, A AMU resllwe. SUPPLIED BY: MGIEF I DEP AR til 9330 BALBOA MOVE SAN DIEGO, CA 92123 01999 Jodc in the Box Inc. T..e droning. and .o.a$oatton. ere Ike preperty ef Jed In the Ow Ise _d OM net be wooled er r.Nre bsoed without is oreue twit.+ consent. dates RELEASE: AUG. 5, 2002 P.M. 12 -31 -02 PERMIT: 1/12/04 BID: COMR ON:IN: revisions ELECTRICAL � • CAL • FIRE PROTECTION • ENERGY Mtn NE, BBLIPUE, UABGTON O0004 *4441 • PAL (aa) 4411461 ralIaboa in.00m lfob Sit.:htfp : / /www.abo..da.00m IE).uts 8/1 0/o4 - I A.E. PROJ. NO.: 23098 site information IBC TYPE: CONVERSION ,A g 8365 ADDRESS: 3742 S. 144TH STREET TUKWILA, WA DRAIN BY: at P.I. SH SCALE: 1l4" = 1'_0« HYA ROOF PLAN M3.0 • MECHANICAL KEY NOTES Q PROMO( ROOFTOP UNIT AND ROOF CURB. NISTAU (NT AND cuits me. TO ENSURE PROPER COIIOENSATE ORJWAGE. PROW FLEXILE CONNECTORS ON WE SUPPLY (MID RETURN AR DUCT CONNECTIONS. PROW DUCTWORK AND AIR DISTRIBUTION DEVICES AS NOCATED ON THE PLAN. REFER TO AR CONDITIONING UNIT SCHEDULE FOR ADanaNAL REQUIREMENTS. �2 FACTORY MOUNTED SMOKE DETECTOR INTERLOCKED TO SHUT DOW( INST ON DEIEC1ON OF SMOKE. 1 WALK --IN BOX ROOF MOUNIED UNITS BY OTHERS r ELECTRICAL aorNEcnon BY CONDENSATE owuti CONNECTION GAS 'CONNECTION BY (TWICAL FOR 2 UNITS) i TYPICAL FOR 2 UNITS) loco CFM 1665 CFM *NT FOR WATER (EATER BY ORERS. WMTAIN to' moI. FROM OUTSIDE MR INTAKES • ' t 12X16 DN IiAAINTAIN 36" CLEAR PER NEC 1280 CFM I I I 22X24 DN .►� ~ `�.. 24X14 `� �.� �►� �, L_ 1' 34X14 E»IAUST/MUA CON1ROL PANEL 1310 • i—- --1885 CFI( x f \ J VTR BY OTHERS. M 11IAN 10' MM. FROM OUTSIDE AR WAKES DUCTS HORIZONTALLY INTO CLG. SPACE, SEE SHEET M -2 FOR CONTINUATION, SEAL ALL DUCT ROOF PENETRATIONS PER SMACNA GUIDUNES ICE MACHINE ROOF MOUNTED UNITS BY OTHERS 0 r L 1 rRy OFT *Iv, APR 26 4 E►ur • r a • CLEANOUT MR VENT RESTROOM EXHAUST FAN DETAIL BY P.C. ROOF ROOF FLASHING BY C.C. AC UNIT DRAIN DETAIL DISCHARGES OOP COOKING EQUIPMENT EQUIPMENT SECTION AT CALL HOOD 2 I.., • A/C UNIT FIELD OJT EXHAUST OPENING IN HOOD SO THAT DUCT CAN EXTEND STRAIGHT UP. 3" MINIMUM CLEARANCE. 12 MAXIMUM CLEARANCE (TYPICAL ENTIRE ENCLOSURE) NOT TO SCALE NOT TO SCALE NOT TO SCALE COUNTER- FLASHING BY G.C. INSU AI'NI BY G.C. CANT STRIP BY G.C. ROOFING MEIIBRAIIE St INSULATION BY G.G. ATTIC INSULATION AC UNIT CURB DETAIL NIT BUC WHT AVERAGING REMOTE SENSOR. VERTICALLY MOUNTED 60" AFF AC-1 TEMPERATURE SENSORITHERMOSTAT WIRING DIAGRAM 5 "--0" MIrRIUM 1 1 \--THERMOSTAT HORIZONTALLY MOUNTED 54" AFF N OFFICE DISCHARGE SCOOP ►. fir■ i w ilye io c:; . r 1 4 . I N EQUIPMENT MOWN AT PRYER HOOD A/C UNIT 1" x 4' WOOD NAILER GREASE EXHAUST FAN ON VENTED BASE. SET LEVEL. wA CLEARANCE. 12" (TYPICAL ENTIRE ENCLOSURE) 3" moor MAX. CLEAR. (1W. 4 SCES) REMOVABLE ACCESS PANEL 1 HOUR RATED ACCESS DOOR +10' -11" • A.F.F. SUSPENDED C LUNG ii +tr-ur A. F. 1 HOUR FIRE RATED ENCLOSURE. REFER TO DETAIL 16/A9.0 GREASE EXHAUST DUCT PER SPECIFTCATIONNS (METAL FLASHING MOUNT EXHAUST HOOD PER HOOD DRAWINGS MAKEUP AIR PLENUM COOKING EQUIPMENT • PRONDE 1/4' BUM CAL* EACH SIDE OF GA ET IMMEDIATELY PRIOR TO SETTING Ak U T. SUPPLED BY OM NW. ASSEMBLED a INSTALLED BY G.C. A/C UNIT MOUNTING CURB FURNISHED BY NECKN. CONTRACTOR.. or VIN). LEVELED AND INSTALLED BY Gt. NOT TO SCALE NOT TO SCALE Nar 1OSCALE IIMIAPPED INSULATION COQ mos ROUND DUCT RIOT ROUND MEET METAL DUCT BALANCING DAMPER WRAPPED SUPPLY DUCT BALANCING HANDLE. LOCK INTO POSITION MD MARK PERMANENTLY. COLORED UPON NOTES: 1) PROVIDE AT FLEXILE DUCT CONNECTION METAL OR "PANOUIT" ORAISANO ON THE INTERIOR FLEXILE DUCT HELIX. SECURE THE INSULATION OVER. THE DRAW BAND IMTH AN ADDITIONAL DRAwsANND. 2) PIROVIX BEADING ON ROUND METAL DUCT 12" OR LARGER N DIAMETE 3) PROVIDE Isamu 4' COLLARS FOR ATTACHMENT OF THE FUMBLE DUCT TO ROUND DUCT, DAMPERS AND DIFFUSERS. 4) BAND RIGID ROUND DUCT INSULATION TO DUCT AND PROVIDE TAPE FOR INSULATION OVERLAP. REMOTE SENSOR VERTICALLY DISCONNECT SNITCH II0UN7ED 60" AFT 1MIT ILK MHT O a AC-2 TEMPERATURE SENSOWTHERMOSTAT WIRING DIAGRAM 3— STARTER MOTOR 00N1R0L PANEL MOUNTED ON MUA -1 DISCONNECT SMATCH IN CONTROL PANEL (TYPICAL) • WIRING BY E.C. (TYP.) CONNECTION DETAIL AC -1 \—THERMOSTAT HORIZONTALLY MOUNTED 54" AFT N OFFICE "—CIRCUIT BREAKER I i f I iF 0 0 0 Li L2 L3 INSULATED FLEXILE DUCT PROTECTION SADDLE DIFFUSER STARTER COLLAR (MINIMUM 4 . PRE - -AIRED CONTROL PANEL 11 12 13 D 00 14 0 15 ( 16 0 4 0-1 ANSUL 5 (C)--j 1 Q' — � KITCHEN 2 O,_ ON —OFF NOTES; 1. HOOD EXHAUST FANS TO 6E ELECTRICALLY INTERLOCKED 'MN1H A/C UHT. EVAPORATOR FAN BY E.C. 2. ALL CONDUIT, MIRE AND J -BOXES BY E.C. IMAM AND avow AM WWI' WIRING DUMAN • FLEXIBLE DUCT CONNECTION . 1' X20 OAUCE GALVANIZED SUPPORT SUMP NOT TO SCALE FIELD IMRED BY E.C. (TYPICAL) MUA-1 NOT TO SCALE SQUARE TO ROUND ADAPTER (F REWIRED) CEILING SUPPLY DIFFUSER MATH LAY --IN FRAME (SURFACE MOUNT FRAME SIMILAR) NOT TO SCALE DROP FULL. SIB FROM HVAC UNIT i _________ ._\ 45' ENTRY FITTING (TYPICAL) MAN TRUNK DUCT REFER TO PLANS FOR DUCT SIZES. SUPPLY DUCT CONNECTION ELEVATION OF 10111,A C1 o , APR 2 9 7%4 0 bto MAIN TRUNK DUCT NOT TO SCALE "1 r *g EI VE0 71 *ti lt 4 14PR '� r 2004 4 47E4 • RELEASE: AUG. 5 2002 P.M.(JB ONLY): 5 12-31-02 PERMIT: 1/12/04 BID: CONS1RUCDON: SCALE: OpARIVANT 0330 BALBOA A■ENUE SIN DECO, CA 92123 01999 Jock in the BOX Inc. Thies drawings sr* grspsrty �f A gs Mac Ise aid dm, Nat M aagNM or neudeaM without N. proles, mitten awmant. A.E. PROJ. NO.: 23098 site information MK TYPE: CONVERSION 8365 ADDRESS: 3742 S. 144TH STREET TUK WILA, WA DRAWN BY: '• "N• SH MECHANICAL DETAILS M4.0 • 0 • I IINICHANICALSWOOLS AND AIIIIIRIVIATIONS 4==F cE3 f=p=* C:12=f EIDLul +:1E:Ef 4a3 tr+ E2 ffIg 01. 4 : 1 4 0 AFF BOO BHP BTU B/UmR 08 EAT ESP FOB FOT FPM HZ LAT NC OSA PD PSI TSP RH TYP UC WC vs • NEW OUT METAL. DUCTWORK SUPPLY OR OUTSIDE A11! DUCT RETURN AN DUCT EXHAUST AN DUCT oucTMaMC TRANSITION DUCTWORK TRANSITION-RECTANGULAR TO ROUND N CLNED RISE N CUOMO( W OUND DROP IN DUCTWORK SUPPLY DUCT ELBOW UP OR DOWN RETURN DUCT ELBOW UP OR DOWN EXHAUST DUCT ELBOW UP OR DOWN DUCT ELBOW WITH AWED TURNING VANES ROUND SPIN -IN IM1M D11NPot FLDMILE DUCT CONNECTOR FIE DAMPER COMeINA11ON FIRE/SMOKE DAMPER VOLUME DAMPER FLEXIBLE DUCTWORK SUPPLY DIFFUSER RETURN GRILLE EST GRILLE ROOF MOUNTED EXHAUST FAN CElLI4I MOUNTED EXHAUST FAN N - LM►E CABINET FAN UNIT THERMOSTAT TEMPERATURE SENSOR K amm mom AREA SMOKE DETECTOR DUCT SMOKE DETECTOR CONNECT TO EXISTING DIFFUSER DESIGNATION AND CFM PLAN NOTE DESIGNATION REVISION DESIGNATION MEEHANICAL EQUIPMENT DESIGNATION ABOVE RIMED FLOOR BOTTOM OF DUCT BRAKE HORSEPOWER B RITISH THERMAL UNIT B RITISH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE DRY BULB ENTERNG AIR TEMPERATURE EXTERNAL STATIC PRESSURE FLAT ON BOTTOM FLAT ON TOP FEET PER MINUTE FREQUENCY LEAVING AIR TEMPERATURE NOISE CRITERIA OUTSIDE AIR PRESSURE DROP POUNDS PER SQUARE NCH TOTAL STATIC PRESSURE RELATIVE HUMIDITY TONICAL UNDERCUT MATER COWAN WET BULB DIAMETER NOTE BIM PNO■EiCT MAY NOT USE EVERY SYMBOL OR DEICE APPEARING ON TINS LEGENIL ROOFTOP AM comma UNIT SCHBOULII )11111 Cr2.141 EAT TOTAL SENSIBLE EER FUEL INPUT OUTPUT VWOL T'S 0 (MM•MI) (S1W *) OM AR) (R111/t'IR) (STU/MHR) es _ , , K•� • .�1E :•.:� L '._'Z L� L' [ .J���I•1. • • •�L.-_ •I L� ' I 1 ! NIL _. .•y. . �.. ►'•� PE.It/A..1.' � LI - UL•�' !' . •., T [ 0 . 1 .000 000 11.0 r ' 000 1 • , • . � Y Y 'Y �m 3.0 E X d0 U7111111 ,•11 •.. 1) FURNISH S" HIGH FACTORY FA01lICA1ED FULL PERIMETER INSULATED ROOF CURS. 2) SET MINIMUM OUTSIDE AIR AS SPECIFIED ABOVE. OUTSIDE AMR DAMPER SHALL FULLY CLOSE ON UNIT SHUTDOWN. 3) UNITS SHALL HAVE 5 MINUTE TINE DELAY ON COMPRESSOR RESTART. 4) UNITS SHALL HAVE MODULATING ECONOMIZER WITH WHOLE ENTHALPY CONTROL 5) UNITS SMALL HAVE FACTORY MOUNTED AND WIRED DISCONNECT SWITCH. d) UNITS SHALL HAVE FACTORY INSTALLED PHASE LOSS PROTECTION. 1 AC-1 SHALL HAVE BAROMETRIC RELIEF DAMPER. AC-2 SHALL HAVE POWER EXHAUST. 8 UNITS SHALL HAVE FACTORY MOUNTED SUPPLY SMOKE DETECTORS. PROVIDE RELIOTE AUDIBLE ALARM WHERE REQIINED BY CODE. 9 TO COORDINATE PURCHASE AND DELIVERY OF ROOFTOP UNITS CONTACT LLOYD PIKE • YORK: PHONE 918 - 279- 9675,,, FAX 918 -451- 6072, EMAIL Mopd,pkNyoric.com. 10) ROOFTOP UNITS SHALL BE PURCHASED BY THE CONTRACTOR THROUGH JACK-IN-THE-90X NATIONAL ACCOUNT. CONTRACTOR SHALL INCLUDE COSTS FOR EQUIPMENT, RECEIVING, HANDUNG, STORAGE OF REQUIRED), HOISTING, NSTALLA110N, AND STARTUP OF THE ROOFTOP UNITS. CONIRACIOWS RESPONSIBILITIES SHALL ALSO INCLUDE WARRANTY ADMINISTRATION. EXHAUST FAN SCHEDULE MARK MANUFACTURER FACIURER MODEL TYPE DRIVE - PERFORMANCE ELECTRICAL " ACCESSORIES APPROX. SERVICE TYPE AMR • EXT. FAN SONES VOLTS /0/HZ FAN WEIGHT FLOW STATIC SPEED MOTOR () (CFM) (N.W.C.) (RPM) HP REMARKS / 1 2 3 CENTRAL BLOIER CENTRAL BLOWZIER GREENHECK RE -15 RE-15 CROSS -DGEX CURB MOUNTED GREASE EXHAUST'S LT CURB MOUNTED GREASE EXHAUST CURB MOUNTED CETNTRFUGAL BELT DIRECT lees 1310 500 0.75 0.75 0.36 1366 1276 1300 ammino 9.o 20els/do 1 1 1/8 RC„ 0S RC„ DS eO.BS;OS,RC 26 350 FOOD 1 HOOD 2 TOILET ROOMS 3 -SPEED MOTOR.SIETCH PER ELEC SHT ACCESSORIES: BS -BIRD .SCREEN. BD- BACKDRAFT DAMPER, OS- DISCONNECT SNITCH,- RC-- PREFABRICATED VENTILATED ROOF CURB, SC -SPEED CONTROL / NOTES: 1) EF -1 AND EF-2 SHALL HAVE MINIMUM 12` HIGH CURB, HINGED FAN HOUSING, DISCHARGE SCOOP, AND GREASE RESERVOIR. 2) ACCEPTABLE ALTERNATE MANUFACTURERS FOR EF -3 NNCWDE GNREENFECK AND PENN VENTILATOR. .3) TO COORDINATE PURCHASE AND DELIVERY OF KITCHEN DCHAUST FANS CONTACT DAVE PETERSON OR ELJNNOR BUCK • CENTRAL BLOMENF PHONE 1- -800- 473 -3182, FAX 626 - 330 -9406. EMAIL infollkentrawlower.com. 4) KITCHEN EXHAUST FANS SHALL BE PURCHASED BY THE CONTRACTOR THROUGH JACK -IN-NE --BOX NATIONAL ACCOUNT. CONTRACTOR SHALL NCLUDE cosis FOR EQUIPMENT, RECEIVING, HANDLING,. STORAGE (F REQUIRED), HOISTING, NSTALLA1ION. AND STARTUP OF THE KITCHEN EXHAUST FANS, CONTRACTOR'S RESPONSIBIUTIES SHALL ALSO INCLUDE WARRANTY ADMINISTRATION. / HEATED MAKEUP AIR UNIT SCHEDULE MARK 1 MANUFACTURER CAPTIVE AIRE MODEL NHMUA1r -G10 TYPE DIRECT FIRED GAS VOLTS/Via 208/3 PERFORMANCE AIR FLOW (SFM) 1280 EXT. STATIC 0.75 FAN SPEED (RPM) 1150 FAN MOTOR HP 0.5 GAS HEAT FUEL NATURAL GAS NPUT (81U/HR) 140,000 OUTPUT (BTU 41 R) 140.000 APPROX. WEIGHT (LOS) 350 SERVICE HOODS 1 AND 2 REMARKS NOTES: 1) MUA -1 IS FURNISHED AND INSTALLED BY CONTRACTOR. 2) FURNISH AND INSTALL EXOH/MIUA CONTROL PANEL. CONTROL PANEL SHALL INCLUDE MOTOR STARTERS FOR E -1, EF-2. AND MUA-1, TERMINALS FOR ANSUL SHUTDOWN, AND INTERLOCK CONTACTS FOR AC -1 AND AC -2 TO START/STOP RTU SUPPLY FANS. 3) MAKEUP AIR UNIT AND CONTROL PANEL SHALL BE PURCHASED BY THE CONTRACTOR THROUGH JACK-IN-THE-BOX NATIONAL ACCOUNT. CONTRACTOR SHALL INCLUDE COSTS FOR EQUIPMENT, RECEIVING,, HANDLING, STORAGE (F REQUIRED), HOISTING, INSTALLATION. AND STARTUP OF THE MAKEUP AIR UNITS. CONTRACTOR'S RESPONSIBIUTIES SHALL ALSO INCUJOE WARRANTY ADMINISTRATION. 4) TO COORDINATE PURCHASE AND DELIVERY OF EXH/h1UA CONTROL PANEL CONTACT DAVE RHODES 0 SUPREME FMt PHONE 909 - 849 -6778, FAX 909-849-7091 5) TO COORDINATE PURCHASE AND OEUVERY OF MAKEUP AIR UNITS CONTACT JOHN SHIRO(O CAPTIVE AIRE: PHONE 1 --800- 326 -3509, FAX 602- 926 -6811, EMAIL rrg880ooptiwoir..com. GRILLE„ REGISTER AND DIFFUSER SCHEDULE taw v A B C MANUFACTURER TITUS 'TITUS METAL AIRE thS --AA 114S-AA RHH TYPE SQUARE CONE SUPPLY DIFFUSER SQUARE CONE SUPPLY DIFFUSER HINGED FACE EXHAUST GRILLE NECK SIZE FACE SIZE SL` (L "X PER PLAN 24` X 24 " 12" X 12" PER PLAN 10' X 1 12"X 12" FRAME TYPE LAY-IN SURFACE SURFACE FINNISH mint WHITE WHITE NC 430 C30 48` X22" 48` X 24' LAY-IN % ITE <30 rxe ACCESSORIES OBD. STR O METAL AIRE RI#I E TITUS 300FS HINGED FACE RETURN GRILLE SEEWNALL SUPPLY REGISTER ACCESSORIES: 08D- OPPOSED BLADE DAMPER, SIR-- SQUARE TO ROUND 10"X6" SURFACE WHITE <30 080 NOTES: 1) ACCEPTABLE ALTERNATE MANUFACTURERS INCLUDE CARNES, KRUEGER„ METALANRE, PRICE, AND IUTTLE & BAILEY. ASR BALANCE SCHEDULE UNIT AC-1 AC-2 MLUA -1 EF-2 EF=3 TOTALS °mot AIR FLOW (CFM) 1060 1655 1280 0 0 0 RETURN AIR FLOW (CM) 2345 0 0 0 0 • .46135 SUPPLY AIR FLOW (CFM) 3400 4000 1280 0 0 0 8880 EXHAUST AIR FLOW (OEM) 0 0 0 1885 1310 500 3695 RESULTING BUILDING PRESSURIZATION (CFM) BUILDING PRESSURE (CFM) +1060 +1655 +1280 -1885 -1310 +300 OVERALL BUILDING PRESSURIZATION SHALL BE APPROXOIATTZY 0.05" W.C. POSITIVE. • A ENERCIY CODE NOTE 1) THERMOSTATS SIV41 BE A 7 DAY PROGNMAIWOE TYPE %Mil A 5 DEGREE DEPDBMD AND IIUTO&IATIC SEEVCK CONTROL PER 1412.2 WASHINGTON STATE ENERGY CODE 2) WPC EQUIPMENT 9MLL MEET THE MINIMUM NIRJM DEWY EFFICIENCY PRONGS PER TALE 14-1, 14-2 AND 14-3 OF THE VIASHRISTON STATE ENEMY CODE. 3) DUCT NSUTATION Alm SEALING SHALL MEET CHAPTER 14 S'EiI."TION 1414 REQI>IRE]rENTS 4) SUPPLY MID RETURN DUCTS N U CODDITIONED DES SHALL BE NSIAATED TO MEN. R -7. ROOFTOP MAC DUCTWORK 90 /1 HAVE A WFA'T1ER BARRER. 5) SUPPLY MD RETURN DUCTS N CONDITIONED SPACES SHALL BE INSULATED TO INN. R3.3. 6) PIPING INSULATION SILALL MW THE REQUIREMENTS OF WASHINGTON STATE ENERGY CODE TABLE 14-6, 7) BUILDING COMPLIES PER WSEC aJMATE ZONE 2 - OTHER FUELS, ELECTRIC RESISTANCE HEATING IS NOT ALLOWED. 0 Golerd/MSCl+aniod contractor shall bid this portion of the project and complete the installation per these drawings. Woe I . ' equipment peaky.* - NVAC units, groom .showe fans, moioo -up air fon, and the achdo t /ruck* -up cir control panel on notional oacoorn devwlopi by JN with the bowd respective ❑ National Air Systeme (HAS) .hall provide the complete HVAC system per these drowbvs. l'he equipment - HYAc units. groom tane oW 'm d ' make -up oir control panel shall be provided oso , e R � yt D p�P ‘i. 21)4 ; b(o Ap R26 24 0 4 • • et, f • 1 O a. io 7 4 di w R V I3 M AR V Of�P 1Mf�N 9330 BALBOA AWN UE SAN DIEM CA 92123 01999 Jock in the Box Inc. w Ask IM Lee lee . d �e espied w repnedueed wItheut Re praises written oeneeat. dotes RELEASE: AUG. 5, 2002 P.M.(JB ONLI #5 12-31-02 PERMIT: 1/12/04 CONSTRUCTION: revisions A PROTOTYPE REV. 10120103 1 O u) 06z LiI V� W bt LLI Ce V) 4) � LL . rell o aro .a I Drees 8/1 0/04 i A.E. PROJ. NO.: 23098 site information MAC TYPE: CONVERSION MECHANICAL SCHEDULES M1.0 .AB # 8365 ADDRESS: 3742 S. 144TH STREET TUKW ILA, WA DRAIN BY: 'N►• SH SCALE: J • I 1 I' DpARTMIENT 9330 BALBOA AVENUE SAN DIEGO, CA 92123 01999 Jock in the Box Inc. drawingsThese and ere She property o/ Inc and ski net be oepied ar reproduced without Its prs 4i us written cement. dates RELEASE: AUG. 5, 2002 P.M.(JIB ONLY): 15 12 -31 -02 PERMIT: 1/12/04 BID: CONSTRUCTION: revisions ME • • PROTECTION • CIHANICAL • ELECTRICAL • FIRE ENERGY 1844 114TH MI NI, BILIMUI, TUNINGTON 98004 PROM (415) 4124441 • ra. (41} 1 = Maingeneralhbosssin.00m Web Sit :http: / /weviaboesein.00aa i Icwuts 8/10/04 I A.E. PROD. NO.: 23098 site information MK TYPE: CONVERSION .mB it 8365 ADDRESS: 3742 S. 144TH STREET TUKWILA, WA DRAWN BY: M• NN, SH SCALE: 1/4" = 1'_O" MECHANICAL PLAN M2.0 i . • • GENERAL NOTES 1. CONTRACTORS AND SUB — CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. 2. COORDINATE WITH NE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE CONDITIONS OF NE PROJECT SITE. PROVIDE DUCT RISES AND DROPS AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION. NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. 3. DRAWINGS FOR HVAC WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS, ACCESSORIES. OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. 4. TO THE FULLEST EXTENT POSSIBLE. TRUNK DUCTS SHALL BE ROUTED BETWEEN THE TRUSSES, SUCH THAT THE BOTTOM OF THE DUCT IS ABOVE THE ELEVATION OF THE BOTTOM OF THE TRUSS. BRANCH DUCTS TO DIFFUSERS SHALL BE ROUTED THROUGH TRUSSES. 5. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL. STATE AND LOCAL CODES AND ORDINANCES. 8- FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5' -0" LONG AND SHALL MEET INSTALLATION AND MATERIAL REQUIREMENTS OF LOCAL CODES. 7. MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AS —BUILT DRAWINGS, ALL EQUIPMENT SHOP DRAWINGS„ INFORMATION ON THERMOSTATS, CONTROL NA RING DIAGRAMS AND OTHER PERTINENT INFORMATION AT COMPLETION OF PROJECT. 8. PROVIDE DUCT INSULATION ON ALL. DUCTS. DUCTWORK 1MTH INTERNAL INSULATION DOES NOT REQUIRE EXTERNAL INSULATION. 9. ALL BRANCH TAKE —OFFS SHALL BE PROVIDED WITH VOLUME DAMPERS. FOR HVAC SUPPLY AIR AND TOILET EXHAUST DUCT SYSTEM. 10. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE TEMPERATURE CONTROL SYSTEMS TO INCLUDE: PANELS. MODULES. RELAYS, WIRING, THERMOSTATS, SENSORS, DAMPERS, ACTUATORS AND ALL MISCELLANEOUS ITEMS AS REQUIRED TO FULFILL THE DESIGN INTENT AS INDICATED ON THE PLANS AND IN THE CODED NOTES. 11. TRANSITION SUPPLY AND RETURN AIR DUCT DROPS IN THE ROOF CURB PRIOR TO PASSING BETWEEN THE ROOF TRUSSES. 12.CONTRACTOR SHALL FIELD COORDINATE AND MAINTAIN ALL REQUIRED EQUIPMENT CLEARANCES AS RECOMMENDED BY THE MANUFACTURERS. MECHANICAL KEY NOTES 01 DUCT TO ROOFTOP UNIT, SEE SHEET M -3 FOR CONTINUATION, ROOFTOP UNIT LOCATIONS/INSTALLATION NOTES. PROVIDE FLEXIBLE CONNECTORS ON THE SUPPLY AND RETURN AIR DUCT CONNECTIONS. PROVIDE DUCTWORK AND AIR DISTRIBUTION DEVICES AS INDICATED ON THE PLAN. REFER TO AIR CONDITIONING UNIT SCHEDULE FOR ADDITIONAL REQUIENTS. C2 FACTORY MOUNTED SMOKE DETECTOR INTERLOCKED TO SHUT DOWN UNIT ON DETECTION OF SMOKE, SEE SHEET 141-3 FOR LOCATION. 03 PROVIDE ROOF MOUNTED EXHAUST FAN AND CURB. REFER TO EXHAUST FAN SCHEDULE FOR ADDITIONAL REQUIREMENTS. 0 PROVIDE ROOF MOUNTED GREASE EXHAUST FAN AND CURB. REFER TO EXHAUST FAN SCHEDULE FOR ADDITIONAL REQUIREMENTS. 50 PROVIDE 16 GAUGE CARBON STEEL GREASE EXHAUST DUCTWORK WIELDED LIQUID TIGHT. ®B INSTALL OWNER FURNISHED GREASE EXHAUST HOOD. SUPPORT HOOD PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. TRANSITION FROM HOOD CONNECTIONS TO DUCT SIZES SHOWN. CI PROVIDE MAKEUP AIR UNIT. PROVIDE FLEXIBLE CONNECTOR ON SUPPLY AIR DUCT CONNECTION. SEE SHEET M-3 FOR LOCATION. REFER TO MAKEUP AIR UNIT SCHEDULE FOR ADDITIONAL REQUIREMENTS. TRANS. TO UNIT OPENING AS REQ'D. ®g PROVIDE THERMOSTATS AND MOUNT AT 54" AFF, ABOVE LIGHT SWITCHES. THERMOSTATS SHALL BE HONEYWELL T7300F WITH Q7300A LON SUBBASE. 9 PROVIDE REMOTE TEMPERATURE SENSOR. SENSOR SHALL BE HONEYWELL 17047G. MOUNT AT 60" AFF. Ka PROVIDE REMOTE TEMPERATURE SENSOR. SENSOR SHALL BE HONEYWELL T7047G. MOUNT IN RETURN AIR DUCT ABOVE RETURN AIR GRILLE. 16 6 1(16" COMBUSTION AIR LOUVERS (BY OTHERS) IN DOOR AND IN WALL ABOVE DOOR. REFER TO ARCHITECTURAL DRAWINGS. INSTALL PER UMC CHAPTER 7. O 1 HOUR GREASE EXHAUST CHASE. REFER TO ARCHITECTURAL DRAWINGS. PROVIDE CLEANOUT AT HEEL OF ELBOW AND CHANGES IN DIRECTION. O NOT USED. O BALANCE SUPPLY TO 525 CFM TO HOOD 2. • BALANCE SUPPLY TO 755 CFM TOTAL TO HOOD 1. O DUCT MOUNTED DISCHARGE AIR THERMOSTAT. O PROVIDE REMOTE DUCT DETECTION SIGNAL ALARM FOR EACH AC UNIT AC -1&2). UNIT TO HNC UJDE ALARM LED, ALARM HORN, TEST, MOTE NEST, AND RESET FUNCTIONS. INTERLOCK WITH RELATED DUCT SMOKE DETECTOR. PROVIDE 24V POWER WIRING FROM DUCT SMOKE DETECTOR IN ACCORDANCE WITH DIVISION 16. 03 PROVIDE 5" TYPE 11" VENT FOR 98,000 BTUANR WATER HEATER. OFFSET AND EXTEND UP THROUGH ROOF WAISTED CAP, TERMINATE PER UMC 805. O ELECTRIC UNIT HEATER FOR FREEZE PROTECTION, SEE ELECTRICAL DRAWINGS. 4 1 Ox 10 12 "X12" L 24X14 22X14 OUT OF JOIST SPACE t TO ABOVE CLG. RETURN AIR PLENUM, FULL SIZE OF RETURN GRILLE MAX. HT. POSSIBLE, CONN TO DUCT THROUGH ROOF ANGLE DUCT DN 12X22 DN BETWEEN JOISTS TO ABOVE CL • 12'4 OF TOP OF DUCT IN Jo' 8 "4 OFF BOTTOM OF DUCT DN TO KITCHEN CLG. SPACE r 1 2 OFF BOTTOM OF DUCT RETURN DUCT DOWN TO BELOW SUPPLY DUCT 12 "0 L INTERNALLY UNED DUCT (TYPICAL) I; 4! 12"• • .\\0 v ,":00 No X t)41A-Dit'l REC OR 2 6 200 PEOftli r CE A , TER • •