Loading...
HomeMy WebLinkAboutPermit M04-070 - S AND P MEATSS&PMEATS 1024 ANDOVER PARK WEST M04 -070 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049083 Address: 1024 ANDOVER PK E TUKW Suite No: Tenant: Name: S & P MEATS Address: 1024 ANDOVER PK E, TUKWILA WA Owner: Name: VANAMEN LINDA -SR ACCT FIN Address: ASSOCIATED GROCERS INC, PO BOX 3763 Contact Person: Name: 3USTIN WYATT Address: 12432 HY 99 S, #75, EVERETT WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N, KENT, WA Contractor License No: HERMACLOO5BJ DESCRIPTION OF WORK: INSTALLING ONE NEW CONDENSING UNIT ON ROOF AND ONE EVAPORATOR IN EXISTING FREEZER FOR ADDITIONAL CAPACITY Value of Construction: $18,500.00 Type of Fire Protection: SPRINKLERS Print Name: doc: Mech MECHANICAL PERMIT Permit Center Authorized Signature: �,GGCC.v M04 -070 Permit Number: M04 -070 Issue Date: 06/16/2004 Permit Expires On: 12/13/2004 Phone: Phone: 425 743 -7744 Phone: 206 - 575 -9700 Expiration Date:08 /21/2004 Fees Collected: Uniform Mechnical Code Edition: $46.50 1997 Date: /G'7Jy I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio r the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: )=- Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 06 -16 -2004 • Parcel No.: 2623049083 Address: 1024 ANDOVER PK E TUKW Suite No: Tenant: S & P MEATS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835- 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. doc: Conditions City of Tukwila 'Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS * *continued on next page ** M04 -070 Permit Number: M04 -070 Status: ISSUED Applied Date: 05/05/2004 Issue Date: 06/16/2004 Printed: 06 -16 -2004 z �Z rx w U. 0 0 : N0 . ww J w O z 1- O z 1— LU uj 2 o U O N; 0 t— w w ` ~ H LLO wz o z Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. M04 -070 of law and ordinances other work or local laws Date: .=%'•- Printed: 06 -16 -2004 • tS, APR 13 '04 11 :56AM TUKWILA DCD /PW CITY OF TUKWILC Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. *"Please Print ** P. 2/6 i';n u 1 1' .rilv::i,� Mailing Address: /' /s•x Z 3 S Name: S�+ s �. %, /• �.� 71'� F Off �� IMjr : I « ' n 1 9;ti ',1 ; ' ,,, ' ! ^ igiif1'1 ^' l • Company Name: Mailing Address: Contact Person: E -Mail Address: ' pplications'parmit application (7.2003) 3/2003 Contact Person: T• 4.. f/ �► •004 E -Mail Address: o I .e.4 t? Ii { nquLl} 'GI' h , , j nt *r>, r 5P' :`I r � Ci 1 ;I ii i9r' y r "1•n� N, • . , . ,k : lr ' � � ' { �i I I a i♦ w k C { p .:I.' t'. q, � ,,, "r• f ,A , i i j i ' ; ISM H•,' d i w,!1 a t ltb' 'jkaG14� fl } ! ¢t ,f f � � i� t' 1 , , J1. +t «I "�" ', , ,. IUD c { I t , �I 1 4 .11'9� j i �� '1',. � iyli'fJw311. . rr�l1 fl )1 King Co Assessor's Tax No.: Site Address: / a 2 Y A� .Do ✓ -e - �s.-1 w! Ens r` Suite Number: Floor. Tenant Name: r^ /d /" 7- ,,► 7 3'• New Tenant: ❑ .... Yes [KNo Property Owners Name: Z. L. k C State Zip , r„r '1 ♦ iF,.Mp.r(.w T: ' le)4∎ ,1im' �t y �p l } „ r ,.. 1 i ,t i 1 ` Si lIlly ''f ";1 �p 1C�'+'� t NOr 4.,„,pr 41 I u') +1411 , a'1r I ' Illnl e;'4 ' ,Ir ; 1 11 t'r wi:( �jf ` �: I I gg TO O I 0'' Irf 11" T, �C'M1 t.l 1y , 1 I' • ; � . ; , ' gl:}G r � I 1 t,�' l t,7t , � ,, ;1�{ , , ti ; ! 4 � � � 1 � + ;� ; j.11 ,4 , m « s, � � 9a+�yl�i' � �1 , � �ti� �I,: (11 , ,• ��,�4,;I,�.r x� ^ t tl�� � rl 15 1 { t �V) y2 , I 1 • 1 . 1� t ;_, 4 TOOT .% ' 1 1 {I t f II `{� n� „1 IK Flr 1 r { ,l;; ^yyI d 3 ;.. ` r ,a , , t. , t, ' i K „n q,, gl,, 1,,, q { I q1, {In � e •1 t' +'. r , , �� ■i �, :, �t N (J �i�'!„ � �iYti';y ,� ,.,.. „ I ,�pl, { � ,' I n ,. I � 1�; - 7,d »L� jlq�' ,..��F,.{1d,.i1 ...t,l,e..1,2,- ,.`I. { „��1:��'I"'�'. f!• 1v' �'Iln!' l�r. "rin, h (1`liii�.i.l�r�� Ih .,1:.1!� «S.:.WI f.,�'I;1{nall, itl..� 1}, , ,I �.,d l��ll� 4;v41� � {4da� .f 1a�rfN'� � � 11..��..r,.��':tUl_�1v��'b.. ,�t ,1 V411 f!1�:1 Mailing Address: / Z y 3 2 h% 9 •-- -�•-, 9 '9 S. 90 5� E -Mail Address: Je..4 s f what ••Z�. —•:, , e o �,y 1�I 1I r'i . i8'' a t, y t!� 4t�i;ili•I'I,,gtr'' JI � 4 fJs f i ! , p�{ � � i i Ir j� ., "�9 jl;'91i nr I n'!' 1 i }'! �N1�1Lj{' n�, 1 +ll ' 1 1. Ii;. ,1, liiiv':pn�1h; ,,, }i1' , I ; 1 uvh j elly; :,'191Ld4�ii;li'd �1 1 y «+ 1 'I ✓ ✓ ✓ ✓ , t li” Company Name: Mailing Address: /2 Y 3 2 N y fir► -�. 9 9 S �# Jot 7, "eat bra► A . ivt C Ems• -��'r� w� 9? Y 2 C' FL ; � ti ti�ktiaC '' ei N f am '' n r S ► tl ( phlr + 1 11 t pp h n , , ia l' bm'� + 4,4:74 k A II Ir ti^ r .I, � r N`' 'Y''T: LfYI't'ir ,� eb "i t , +n '• I '� ,�� �' o i :,,t'5,.�'�•4 , 5a, � ;+ uCd�l' t ,P!elh r . r. dt� ,>SI)i,l�l�..u,d,a.�'..:,�.r tt• dhf` I" I: I ��IyL I�un( yl; eral: �. mur' �r .J,l�ll.olNlln��l,ll.� Company Name: SL. -te /e /4• c or-' Page 1 e. .r s l� • Day Telephone: y 2 Se 3. '9 Ae'V Ev- e. -I•e7 -- 9g 2vY City State Zip Fax Number: ' 3 9 3/ v City State 7 Mailing Address: / Z SO 3 /3 ../- .e*■4 ■ar, ,lr.,e //� .,., 1 .� City ba 21 :1,4i r i ?, i Id 5 riJ r!uJ��iipl j [ State ceiYi Zip Contact Person: S.+ :� G ✓ 7 -a..?14 E -Mail Address: Js i s�. %+ �' '`"� +/i�. --e.�. ? . co o•-% Fax Number: y2 S': 3 SS• 9 3/ V Contractor Registration Number: G✓YA? 77 C D YP/'7. 7 Expiration Date: 5 y * *An original or notarized copy of current Washington State Contractor License must be presented at the time of pennit issuance "" Day Telephone: Ce2 x'13 . 3 YS' Zip City Day Telephone: Fax Number: • i Yp �, m ± m �, r� rry �i 1 i t' t 'I F 11 ,,,, t 11 r�l``•Ili, i'i11�ft'��{l'r,i1 le��h I t, 1�Iil,Pt,l•, t�h:, i a I� f, , 1 d 1� h ' Yt t t' �Crnrli ;tdt�� r!,1,11,1, ,�, i.p'I 4 11),44:1 l lh i•t K Ih {•v G.,••4 9 a o a' State Zip Day Telephone: 5 4 ' D. '/D Fax Number: Y23-. terp. VO7 6 , Unit'7'3'pe :, ., .... r .';Qty,;' ;',Vni , ,.,, ", . , ,,.., „ Y., ;.; .LJ iIV e:;M . 4; , : :,';'Q, 410' i o gate s, r:; , : : Furnace-4100K BTU Air Handling Unit »10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler 3- 151'1P /500,000 BTU / Floor Furnace Ventilation Fan _ 15-30 HP /1,000,000 BTU Suspcndcd/Wall/Flooi' Mounted Heater Ventilation System 30 -50 HP/1,750,000 13'1'U Appliance Vent Hood 50+ HP/1,750,000 BTU • Heat/Refrig/Cooling System Incinerator - Domestic Mr Handling Unit <= 10,000 CFM / Incinerator— Comm /Ind APR 13 '04 11 :58AM TUKWILA DCD /PW P.5 /6 �•1 (1� N I r " Intl- 'r11,� "'�. I,rr N•ylllli{�iili�'L ,. 1 IP , ,,.—r �•r 1 ' (1 f rf� n`Si �l 1 1 �• 1 r Il Sl G! I' a ip' ;�III�JI�: �I LH7r �71 r � �' fir .+ i�Y�o�l tI ��K` { .'� ' �� � ,r v � , 1 ( o r ' , n y !• W't�l (•` 1 Il 37 4 r r 1t( ' 1 ll • ILI.� !Ui � ll I dNil't 1 ', b j k Ili ■n i�l� y 1 q� ' i T" „ h' a n 1 4"'"' i:l l {' I `i11��,yy (' I ; `^� , rA. 1 ,� i ii . ,, . 1 � i�i�ili r .:LA l]: +I}Ir Ihnl•,1 1: , f �I �A918 ►'. '�l �df 9, 19a1�AlY,'dl rr � li•rl ivmw.r v'�lo'f y��lrl .!y Tf(!19 MECHANICAL CONTRACTOR INFORMATION Company Name: 0 7 •P..e- •?.. C' Mailing Address: / 2 '' S 2. /y y 4.....t , 9 7 S # .73` es../1 8' Zd Y City State Zip Day Telephone: *'? S: 7 Se 3. .7- 4'Y E -Mail Address: ti s 7 GIP e... yn71 r- e-21 • coo•-, Fax Number: V 2 ?-?-YV' 3 "- ,S-/Y Contractor Registration Number: wf-^ rr'Ke 0 S8 Expiration Date: 4 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuances' Valuation of Project (contractor's bid price): $ / ' SD o Scope of Work (please provide detailed information): .27-1 rfat // H-e. C.- , —e r / ' 6/.y/'r Ov 1 /(* e.e ✓tea e, p •-a 7 sr �'� .- �t ♦ T 7 • .�I r^ Contact Person: 3:4 %+ G✓ - Use: Residential: New ....0 Replacement •... 0 Commercial: New .... [�%] Replacement .... 0 Fuel Type: Electric 2K Gas ....0 Otber: Indicate type of mechanical work being installed and the quantity below: 11 I; J 1 Y •'iy °Ilj n w{ o•Ir .1' tl 8 t Pt q I�ylll'I I ,, Ihy,S;h, Ih u 1. 1r l;a wrr L irl ( t.91:( ra�J'N I'f•yrl'��f'4Ak�,l'ri .19+^ ! � }r uLl�ifl li 1! 11;. i1t 11 1. :. Value of Construction — In all cases, a value of construction amount should be entered by the applicant, This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. -• The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE T7F,D GENT: Signature: �' J `'"�'� ��•�'� Print Name: CZ. r F' :, L•/x • Mailing Address: / 2 Y 3 Z /Y� --�. 79 5 ' , ` '7 $" \applications'permit application (34003) 3/2003 Page 4 Date: Day Telephone: •Z Y 3 . -74 yY E ve ✓ -! G•��4 "P 0 2 City Stue zp Date Application Accepted: — .V =o Date Application Expires: Staff Initials: 1 Payee: JUSTIN S. WYATT ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payment Check 2729 MECHANICAL - NONRES PLAN CHECK NONRES RECEIPT Parcel No.: 2623049083 Permit Number: M04-070 Address: 1024 ANDOVER PK E TUKW Status: APPROVED Suite No: Applied Date: 05/05/2004 Applicant: S & P MEATS Issue Date: Receipt No.: R04 -00732 Payment Amount: 46.50 Initials: SKS Payment Date: 06/16/2004 09:42 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount 46.50 Account Code Current Pmts 000/322.100 37.20 000/345.830 9.30 =190i 06/16:9716 TOTAL-. 411.50 Total: 46.50 Printed: 06 -16 -2004 •, 3 Pr,e c' e YIA(0.1- Type of Inspectir.; Al r A PI 611V(i Dam Called: di Special Instru ion Date Wanteclfg i ti i tr‘ci TI L Requester Ph ne No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 • 14 Approved per applicable codes. Corrections required prior to approval. COMMENTS: tr r Co tiA i n Le 4--e T; vv4 • 11;4 Inspecto Date: 8 ) • ,.., t -u Ei $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • Projec t* Z cil P7/7,, Type of pection: /i 1 - - - ''' -1 ( e- 7-e-P f Address: k7 V .,. eliorfez / 7- Date Called: '7- P' 1 Special Instructions: /4 / la-6'6 4 12f— . ,12( /0 : (.D Date Wante• Requeste : ..... • i Pho o: / p M ' 7.3 7 CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: I lnspec IN ION NO. INSPECTION RECORD Retain a copy with permit (206)431-3670 ..._ Date: $ EINSPEC7" FEE REQUIRED. Prior to inspection, fee mu t be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Type of Ins Action: A/A / Address: / Z 5 0 7 Al ,V, i- P Date Calle 1.--66 0 (lTv /r,T (21L - ,ii ds -Ib > e a--A/ .5", �4 ," /,l 5 er / , tjZ j /v/id Qrq(f h (,tl'nn /V �,ti, '('7 » > Z) c) Pro'ec: . "� )0 /77gff73 Type of Ins Action: A/A / Address: / Z 5 0 7 Al ,V, i- P Date Calle 1.--66 Special Instructions: Date Wanted: a.m. Requer: C", (— /in / l (47 - 1-1- Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. Corrections required prior to approval. p elpt No.: INSPECTION RECORD Retain a copy with permit !Date: (20 )431 -3670 !Date: I r Q REINSPECTION f E REQUIRED. Prior to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. i Project: .... °TA- Type of Inspection:11 1 , 40kkik - t vA Adcrtt55_, A? E _ Date Called: LO P-g — o i l Special Instructions: Date Wanted: to olg. .09 a.m. P.m. Requester: .■.' Phone No: 3 4,... c . c ... ,INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 D Approved per applicable codes. COMMENTS: - rcSuft_ Inspector' e ) ' 4/v.1 1 Date: ‘,2troy (206)431-3670 - Corrections required prior to approval. LJ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: File: M04 -0070 35mm Drawing #1 -3 (E) 6x27 BEAM -- (E) Et ABOVE Lu (.) ca 2x6 @ 24"o. FREEZER A/SKS-2 P/r 4. NEW CONDENSER (1030- A! J .....-A (E) 4x LEDGER /11 SHUTLER Ob CONSULTING WW1 ENGINEERS Inc. 12503 Bel-Red Road, Suite 100 Bellevue, Washington 98005 425)450-4075 FAX: (4.25)450-4076 NEW FAN UNIT (310#) • C..) 1 )--- INSIDE FACE E) 4x16 @ (E) 6x16 BEAM SCALE: 1 /8" = 1'-0' INCOME LTR# _ JoB S&P MEATS Tukwila,. Washington SHEET NO SKS-1 OF CALCULATED BY J1-I SCALE NOTED (E) 4x16 @ DFH2 SLEEPER (TYP.) B/SKS-3 ROOF FRAVI\G PLA\ (E)2x4 @ 24"o.c (TYP.) / CMU 0 „ WALL BELOW DATE 5-5-04 Job No. 03 NOTES: 1) CONTRACTOR TO VERIFY EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD. NOTIFY ENGINEER OF DIFFERENCES. cin op NAY 1 3 2014 PE RMIT cE isire . inO1-070 MI Ma sHUTLE CONSULTING ENGINEERS Inc. 12503 Bel-Red Road, Suite 100 • Bellevue, Washington 98005 425)450-4075 FAX: (425)450-4076 Flk1 11728720051 "VI 6 x 3 x0 4 1/2 H z" EACH SIDE w/ 1 /2 "0 M.B. A/S JOB S&P MEATS Tukwila Washington . SHEET NO SKS-2 OF CALCULATED BY JH DATE 5-5-04 SCALE . J N _ 03-01,22A <S 2 SCALE: 4':1 ''=1'-0" 43x3x .)A EXISTING COOLER BOX CEILING ep r Op ro NAY 1 3 2004 P O4%417. 000173 FAN UNIT (310fi MAX.) 12503 Bel—Red Road, Suite 100 Bellevue, Washington 98005 425)450-4075 FAX: (425)450-4076 "0x3" LAG SCREW AT EACH CORNER EXISTING 2x6 24"o.c. OVER FREEZER 40 .2o - ;s7 °NA L .\)\ EXPIRES, 11-28-2005 SIMMER CONSULTING ENGINEERS Inc. EXISTING 6x16 BEAM R/sKs SCALE: JOB S&P MEATS Tukwiia, Washington SHEET NO SKS-2 CALCULATED BY JH DATE 5-5-04 SCALE NOTED Job No, 03-01 ,22A NEW CONDENSER (10300 4x6 SLEEPER (TYP.) 16d TOENAILS @ 12"o.c. (TYP.) NEW BLOCKING --- EXISTING PURLIN 4x16 SHUTLER CONSULTING ENGINEERS, Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425) 450 -4075 FAX (425) 450 -4076 STRUCTURAL CALCULATIONS FOR: NEW ROOF MECHANICAL EQUIPMENT S &P MEATS 1024 ANDOVER PARK EAST TUKWILA, WASHINGTON PROPOSED BY: WYATT REFRIGERATION CO. 12432 HIGHWAY 99 SOUTH, UNIT 75 EVERETT, WA 98204 (425) 743-7744 DESIGN CRITERIA: CODE ROOF LIVE LOAD WIND LOAD SEISMIC ZONE CORRECTION LTR# CIN o : Tu APPH 313 10 ?034 i s." As ts,(3∎ O i_ JOB S &P Meats SHEET NO COVER OF CALCULATED BY Ich DATE 06/08/2004 CHECKED BY DATE SCALE JOB NUMBER 03- 01.22A FILE COPY tgrairfiaif UNIFORM BUILDING CODE, 1997 Edition 25 PSF SNOW LOAD 80 MPH ZONE, EXPOSURE "B" III, Z =0.3 cITA TIVED JUN 0 8 2004 PERMIT CE NTER flj�L/.79 IMAM SHUTLER _ ■ CONSULTING ENGINEERS Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425)460 -4075 FAX: (425)450 -4076 JOB S&P MEATS Tukwila, Washington SHEET NO SKS -1 CALCULATED BY JH SCALE NOTED OF DATE 5 -5 -04 Job No 03- 01.22A (E) 2x6 ® 24 "o.c NEW FAN w ABOVE FREEZER c� (310 #) w A - SCALE: 1/8" = 1' -0" ROOF FRAMING PLAN NOTES: 1) CONTRACTOR TO VERIFY EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD. NOTIFY ENGINEER OF DIFFERENCES. 'UM III SHUTLER CONSULTING ENGINEERS Inc. 12503 Bel —Red Road, Suite 100 Bellevue, Washington 98005 (425)450 -4075 FAX: 425)450 -4076 Joe S&P MEATS Tukwila, Washington SHEET NO SKS -2 OF CALCULATED BY JH DATE 5 -5 -04 SCALE NOTED Job No. 03- 01.22A t 3 / is x3x0' -4 " EACH SIDE w/ 1/2 "0 M.B. 1/2 "0 A36 THREADED ROD AT 4 LOCATIONS (COORDINATE A /SKS -2 SCALE: 3 /4 " =1' -0" z-- EXISTING COOLER BOX CEILING FAN UNIT (310# MAX.) 1 EXPIRES 11 -28 -2005 1 SHUTLER CONSULTING ENGINEERS Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425)450 -4075 FAX: (425)450 -4078 JOB S &P MEATS Tukwila, Washington SHEET NO SKS -2 CALCULATED BY JH SCALE NOTED OF DATE 5 -5 -04 Job No. 03- 01.22A �a "0x3" LAG SCREW AT EACH CORNER — EXISTING 2x6 24 "o.c. OVER FREEZER — EXISTING 6x16 BEAM B /SKS -3 SCALE: 3 " =1 '-0" NEW CONDENSER (1030 #) 4x6 SLEEPER (TYP.) 16d TOENAILS 12 "o.c. (TYP.) NEW BLOCKING EXISTING 4x16 PURLIN 1 EXPIRES 11 -28 -2005 1 ot� �U N • 0 cn W 0 2 gQ . d , w _ o z ►-. 0 tA� 0 H W W . U. O Cu co 0~ Z . MIAMI u. 11111/111M SHUTLER CONSULTING ENGINEERS, INC 12503 Bel-Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB Lg A SHEET NO OF CALCULATED BY DATE SCALE . .'; • s , „ 414e,d I II 1 0.0,toiii.k,e I I 1 , Gym/4w] l / ' O - 6/5if.tic °71 - MN 1 I NO 1 7 1 -7-1 "t■c‘ LIM C tdi I TI P 0 --df Catrroo ,4 /c) - o . 5" WA c4. c zr 0-1.P .‘Asie (0 /e k,r)1 p /d • f - 'oil) Ram 4,15 51 llitr '1". MIAMI u. 11111/111M SHUTLER CONSULTING ENGINEERS, INC 12503 Bel-Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB Lg A SHEET NO OF CALCULATED BY DATE SCALE . .'; • s , „ t' SHUTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450.4075 FAX (425) 450.4076 JOB 4 ,‘""r 444fri SHEET NO J OF CALCULATED BY Je DATE SCALE . �. a�ari.:: �xw�w..�uv:Lli..�i.:it:tav:3,;,y.i�: ,+s:u:a+,s;,:�, :' UwY ::Lkt'�.�_:�a- :s�d::,�:::.�:+; i.::}:,;5.'.::.:.:✓. nt'w'a aly" �' / L /�l !! (1 ►t,- '� /�� /�II t// 11 w/-6 ■ t VG a - ,kip 54%' j, 6 Tie- ote ■■! r /" ■ ■ OA 9-' i tt ■ ■ ■ ■ ■ ■ ■■ ■ d . J » ' 1 I . ' c ., re z " 14 ' 040 A a ■ ■ ■ V a Pow lcc,j P0-6' 1 1 1 0 ) _ a « 15 A 4 . - oiA? Vuuu Tam) m) g ( t 0 0• ii 0 4 itoo t' SHUTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450.4075 FAX (425) 450.4076 JOB 4 ,‘""r 444fri SHEET NO J OF CALCULATED BY Je DATE SCALE . �. a�ari.:: �xw�w..�uv:Lli..�i.:it:tav:3,;,y.i�: ,+s:u:a+,s;,:�, :' UwY ::Lkt'�.�_:�a- :s�d::,�:::.�:+; i.::}:,;5.'.::.:.:✓. nt'w'a aly" SHUTLER CONSULTING ENGINEERS, INC 12503 Bel-Red Rd., Suite 100 Bellevue, WA 98005 (425) 450.4075 FAX (425) 450.4076 s SHEET NO CALCULATED BY DATE 4 ,- -- e) - g- a� JOB OF SCALE F:C;1Uo"1.'.Sistl..w::. : ��i::[:.; s1r;. i. iti. isl::.. r.• ....«�.'ri:i�l»i„I.:.,s: ".s+i1: �:a: ?i.:�,.u u:.ti:. �Xltiw:...wu, i ' - A4d4 kr- '1 7i4 6 - r b- 3r -v i ,. .: -co +015. /� _ 44,/9 n t 1I /( /• -u,ub = %Of° tM(§1 "4; T IJ ql i l e/ s /�i t It �� bC b ard - 1 °(6' q ,A3 1�� ,. 'K GVN� Lo 56 6 ` (fib /rcb = r 4 . .. VI t_� ,-� ■ 11111e1111111 `ma - Wi4 1 SHUTLER CONSULTING ENGINEERS, INC 12503 Bel-Red Rd., Suite 100 Bellevue, WA 98005 (425) 450.4075 FAX (425) 450.4076 s SHEET NO CALCULATED BY DATE 4 ,- -- e) - g- a� JOB OF SCALE F:C;1Uo"1.'.Sistl..w::. : ��i::[:.; s1r;. i. iti. isl::.. r.• ....«�.'ri:i�l»i„I.:.,s: ".s+i1: �:a: ?i.:�,.u u:.ti:. �Xltiw:...wu, 1. __■ SHUTLER JOB 4/ ■■- CONSULTING _ SHEET NO ENGINEERS, INC �J CALCULATED BY Jr 12503 Bel—Red Rd., Suite 100 Bellevue, WA 98005 (425 450 -4075 FAX (425) 450 -4076 DATE SCALE .:u ,....,,.. o.,. aw;: r.,. .uaa:;L',::.,t..:c.'.t:1�...:.` e (g. j la &, ,� `d ( - Zr ( / /.-`-.9s ( 8V-) - S T • �o�; .rr 407 �.w — i KO " 1 _ r OE O 1 o L 1 , ■ ayo �S ■■■■■■■ ■ ■ ■■■ ■■ ■ ■ ■■ ■ ■ ■ ■ ■ ■■ ■■■ 11 4 oat 11 /19 3 /o) / 11 -rte 1 / ( O& , i a 49? 7 .. t dui - - lo 1 I 1 ■ ■ _-� (- J ag'L,A.1 0 1 1. __■ SHUTLER JOB 4/ ■■- CONSULTING _ SHEET NO ENGINEERS, INC �J CALCULATED BY Jr 12503 Bel—Red Rd., Suite 100 Bellevue, WA 98005 (425 450 -4075 FAX (425) 450 -4076 DATE SCALE .:u ,....,,.. o.,. aw;: r.,. .uaa:;L',::.,t..:c.'.t:1�...:.` Large ;Electrical FILE COPY 3-15 HP Cond Bulletin LDLZ -01A (replaces LDLZ -01. 1 /01) May, 2002 �1 ry al J•i ; in As Z W re 00 W = I- (J)LL. W CC < ▪ d IW Z = W O U • 0 O N � W H 0 W ▪ Z U= 0 Z Unit Model Number Compressor Model Suction Temp. 404A 507 °F (psig) (psig) 90 °Amb. 95 °Amb. 100 °Amb. 110 °Amb. -40 5 6 11,470 10,490 9,520 7,580 -30 10 11 15,530 14,500 13,470 11,440 LD *0300L6 2DF3 -030E -20 16 18 20,750 19,560 18,380 16,040 -10 24 26 26,750 25,320 23,560 21,060 0 33 35 33,130 31,390 29,220 26,200 -40 5 6 13,820 12,750 11,690 9,590 -30 10 11 18,590 17,400 16,220 13,890 LD *0400L6 2DL3 -040E -20 16 18 24,500 23,140 21,790 19,100 -10 24 26 31,200 29,620 28,040 24,900 0 33 35 38,320 36,470 34,630 30,970 -40 5 6 16,730 15,490 14,260 11,800 -30 10 11 22,440 21,070 19,700 16,990 LD *06001.6 2DB3 -060E -20 16 18 29,340 27,770 , .26,210 23,110 -10 24 26 36,970 35,160 33,360 29,780 0 33 35 44,920 42,830 40,730 36,590 -40 5 6 19,140 17,830 16,530 13,960 -30 10 11 25,110 23,710 22,330 19,610 LD*0601L6 3DA3 -060E -20 16 18 32,530 30,940 29,370 26,250 -10 24 26 40,810 38,920 37,050 33,350 0 33 35 49,300 47,060 44,820 40,390 -40 5 6 22,550 21,030 19,520 16,540 -30 10 11 29,550 27,960 26,380 23,260 LD *0750L6 3DB3 -075E -20 16 18 38,230 36,410 34,600 31,040 -10 24 26 47,800 45,630 43,470 39,210 0 33 35 57,490 54,880 52,280 47,130 -40 5 6 28,660 26,850 25,050 21,490 -30 10 11 37,670 35,680 33,700 29,810 tiD 09b0L6 l y 3DF3-090f= -20 16 18 49,030 46,730 44,440 39,920 -10 24 : 26. 62,020 59,280 ; 56,57 .J :;5:171:80Z 0 33 35 75,860 72,600 69,350 62,910 -40 5 6 31,990 29,910 27,840 23,740 -30 10 11 42,040 39,780 37,540 33,100 LD *1000L6 3DS3 -100E -20 16 18 54,240 51,680 49,130 44,090 -10 24 26 67,850 64,870 61,900 56,030 0 33 35 82,110 78,620 75,150 68,260 12 Consult factory for applications above 1.10 °F. ambient. R- 404A/R -507 Discus Compressors Low Temperature Applications � KU, �� U NS T�;, . , . , ws:yr:;�l�n4:`,; z° ''k jr:� . s. fi5 iiiiiifff 7a� r Medium Temperature, Discus, R-40 4A/R-507 > > ASR -ti, Unit Model Compressor Model HP Refrigerant Line Rec.Capacity -"°-.; >t� -Sbubd ` • = • Net" Unit Compressor Length Width Height Connections (OD) ©90% full (Ibs) Dimensions (inches) Data Wt. Model Model HP Liquid Suction Std Opt Length Width Height (dba)* (lbs) *D *0500M6 2DC3 -050E 5 1/2 1-1/8 28 52 36 -3/4 51 -3/4 39-1/4 78 751 *D *0501M6 2DD3 -050E 5 1/2 1 -1/8 28 52 36 -3/4 51 -3/4 39 -1/4 78 751 *D *0750M6 2DL3 -075E 7.5 1/2 1 -1/8 28 52 36 -3/4 51 -3/4 39 -1/4 78 761 *D *0751M6 2DA3 -075E 7.5 5/8 1 -3/8 67 78 36 -3/4 63 -3/4 39 -1/4 82 985 *D *0800M6 3DA3 -075E 8 5/8 1 -3/8 67 78 36 -3/4 63 -3/4 39 -1/4 82 1,020 *D *1000M6 3DB3 -100E 10 5/8 1 -3/8 67 78 36 -3/4 63 -3/4 39 -1/4 82 1,045 *D *1200M6 3DF3 -120E 12 5/8 1 -3/8 67 78 36 -3/4 63 -3/4 39 -1/4 82 1,065 _t, .. ..= �� t +° }•4at •.+9u. .,.'E`�,., t;4�,.1 t Low Temperature, Discus, R- 404A/R507 Unit Model Compressor Model HP Refrigerant Line Rec.Capacity Dimensions (inches) Sound Net Unit Compressor Length Width Height Connections (OD) ©90% full (lbs) Dimensions (inches) Data Wt. Model Model - HP Liquid Suction Std Opt Length Width Height (dba)* (lbs) *D *0300L6 2DF3 -030E co v CD � � 1/2 1 -1/8 28 52 36 -3/4 51 -3/4 39 -1/4 78 737 *D *0400L6 2DL3 -040E 1/2 1 -1/8 28 52 36 -3/4 51 -3/4 39 -1/4 78 741 *D *0600L6 2DB3 -060E 1/2 1 -1/8 28 52 36 -3/4 51 -3/4 39 -1/4 78 751 *D *0601L6 3DA3 -060E 1/2 1 -1/8 28 52 36 -3/4 51 -3/4 39 -1/4 81 781 *D *0750L6 3DB3 -075E 1/2 1 -1/8 28 52 36 -3/4 51 -3/4 39 -1/4 81 805 *D *0900L6 . . 3DF3 -090E - 9. . 5/8 .. 1 -3/8 67. , 78 . 36 -3/4 63 -3/4 . 39 -1/4 82 - . ,1;030 ; *D *1000L6 3DS3 -100E 10 5/8 1 -3/8 67 78 36 -3/4 63 -3/4 39 -1/4 82 1,035 R. 6 Wk. eyw.•R.✓wV ttit r; •" .c J P.�.ti•' S'� �� Low Temperature, Scroll, R 507 a II 404A/R Unit Model Compressor Model HP Refrigerant Line Connections (OD) Rec.Capacity ©90% full (Ibs) Dimensions (inches) Sound Data (dba)* Net Wt. ' ' (Ibs) Liquid Suction Std Opt Length Width Height *Z *0750L6 *Z *1000L6 ZF24K4E ZF33K4E 7.5 10 1/2 1 -1/8 1/2 1 -1/8 28 52 28 52 36 -3/4 51 -3/4 39 -1/4 36 -3/4 51 -3/4 39 -1/4 82 82 671 671 *Z *1300L6 *Z *1500L6 ZF40K4E ZF48K4E 13 15 5/8 1 -3/8 5/8 1 -3/8 67 78 67 78 36 -3/4 63 -3/4 39 -1/4 36 -3/4 63 -3/4 39 -1/4 84 83 910 891 l 'y.. r ►r W f .'. � �'Y'�'.'�i {� Medium Temperature, Scroll R-507, 404A Unit Model Compressor Model HP Refrigerant Line Connections (OD) Rec.Capacity ©90% full (lbs) Dimensions (inches) Sound Data (dba)* Net Wt. (Ibs) Liquid Suction Std Opt Length Width Height *Z *0650M6 ZB5OKCE 6.5 1/2 1 -1/8 33 60 36 -3/4 51 -3/4 39 -1/4 78 574 *Z *0700M6 *Z *0750M6 *Z *0860M6 *Z *1000M6 ZB58KCE ZB66KCE ZB76KCE ZS92K4E 7 7.5 8.5 10 5/8 1 -3/8 5/8 1 -3/8 5/8 1 -3/8 ` 5/8 1 -3/8 78 90 78 90 78 90 78 90 36 -3/4 63 -3/4 39 -1/4 36 -3/4 63 -3/4 39 -1/4 36 -3/4 63 -3/4 39 -1/4 36 -3/4 63 -3/4 39 -1/4 80 80 80 82 800 813 818 908 *Z *1400M6 ZS11M4E 14 7/8 1 -5/8 78 90 36 -3/4 63 -3/4 39 -1/4 82 915 Physical Specifications Rule • * Estimated sound pressure values are 5 feet from the unit. For estimating sound pressure from unit at different distances, deduct the following from the unit values: 10 feet deducts 6 dba, 20 feet deducts 12 dba, 40 feet deducts 18 dba. This data is typical of "free field" conditions for horizontal air cooled condensing units at the outlet of the discharge air. The actual sound measurements may vary depending on the condensing unit installation. Factors such as reflecting walls, background noise, and mounting conditions may have a significant influence on this data. 15 v T ^ LY:'li'` �; g r'�. # i;' ti � ;�c„'!7�k.':w� Medium Temperature, Discus, R- 404A/R -507 Unit Model tVoltage Supply 60 Hz Compressor RLA LRA Condenser Fan Motor Qty HP FLA Air Defrost MCA MOPD Electric Defrost MCA MOPD Defrost Htr. Amps Evap. Fan Amps *D *0500M6C 208 -230/3 20.0 120.0 1 1/3 2.7 27.7 45 50.0 60 40 15 *D *0500M6D 460/3 9.4 60.0 1 1/3 1.9 13.6 20 25.0 30 20 8 *D *0501M6C 208 -230/3 20.0 120.0 1 1/3 2.7 27.7 45 50.0 60 40 15 *D *0501M60 460/3 9.4 60.0 1 1/3 1.9 13.7 20 25.0 30 20 8 *D *0750M6C 208 -230/3 28.3 169.0 1 1/3 2.7 38.1 60 60.0 80 48 20 *D *0750M6D 460/3 12.4 85.0 1 1/3 1.9 17.4 25 31.3 35 25 10 *D *0751M60 208 -230/3 28.7 169.0 2 1/3 5.4 41.3 70 61.3 90 48 20 *D *0751M6D 460/3 12.6 85.0 2 1/3 3.8 19.6 30 31.3 40 25 10 *D *0800M6C 208 -230/3 36.8 215.0 2 1/3 5.4 51.4 80 87.5 100 70 26 *D *0800M6D 460/3 17.9 106.0 2 1/3 3.8 26.2 40 43.8 50 35 13 *D *1000M6C 208 -230/3 39.1 215.0 2 1/3 5.4 54.3 90 87.5 100 70 26 *D *1000M6D 460/3 17.9 106.0 2 1/3 3.8 26.2 40 43.8 50 35 13 *D *1200M6C 208 -230/3 43.2 275.0 2 1/3 5.4 59.4 90 87.5 100 70 26 *D *1200M60 460/3 21.2 138.0 2 1/3 3.8 30.2 50 43.8 60 35 13 -'. ,,t «5.�.x.;, Y ��LL . } . y�:�:; •,� Low Temperature, Discus, R- 404A/R -507 Condenser Air Electric Defrost Evap. Unit tVoltage Supply Compressor Fan Motor Defrost Defrost Htr. Fan Model 60 Hz RLA LRA Qty HP FLA MCA MOPD MCA MOPD Amps Amps *D *0300L6C 208 -230/3 14.4 102.0 1 1/3 2.7 20.6 35 50.0 50 40 15 *D *0300L6D 460/3 7.1 52.0 1 1/3 1.9 10.8 25 25.0 25 20 8 *D *0400L6C 208 -230/3 23.6 161.0 1 1/3 2.7 32.2 50 60.0 70 48 15 *D *0400L6D 460/3 9.2 60.0 1 1/3 1.9 13.4 25 31.3 35 25 8 *D *0600L6C 208 -230/3 25.3 161.0 1 1/3 2.7 34.4 50 75.0 80 60 ..20 *D *0600L60 460/3 11.9 80.0 1 1/3 1.9 16.8 25 37.5 40 30 10 *D*0601L6C 208 -230/3 24.0 150.0 1 1/3 2.7 32.7 50 75.0 80 60 20 *D *0601L6D 460/3 10.8 77.0 1 1/3 1.9 15.4 25 37:5 40 30 10 *D *0750L6C 208 -230/3 27.6 161.0 1 1/3 2.7 37.2 60 75.0 80 60 20 *D *0750L60 460/3 14.1 83.0 1 1/3 1.9 19.5 30 37.5 40 30 10 <'D *_ 0900L6C ::. _ :; _.. « 208 - 230/3:' •„ 33.2: 215.0, : , 2 1/3 _ 5.4 46.9:.. _. 80 `: 87.5: 2 17.0a1 ' *D *0900L6D 460/3 15.0 106.0 2 1/3 3.8 22.6 35 43.8 50 35 13 *D *1000L6C 208 -230/3 37.2 215.0 2 1/3 5.4 51.9 80 87.5 100 70 26 *D *1000L6D 460/3 16.7 106.0 2 1/3 3.8 24.6 40 43.8 50 35 13 Electrical Specifications 16 t Consult factory for 50 Hz. application. Dimensional Diagrams 1 -Fan Condenser LEFT 18 k .-- Length - -0.1 2 „.Ffli Condenser LEFT SIDE FRONT FRONT Width Height ce 6 U O CO 0 CU J N LL W u_ Q. CO —a = W H =: Z1.- 1- 0 Z 1- Uca 0— C1 H W W 0 , — O� U =; O 1- z THINK COLD. THINK LARKIN. • c,;■\, L LH-98 A-r■; 0,19 March 1998 .1 • • t N t t • • WAREHOUSE/INDUSTRIAL UNIT COOLER - sr c Electric Defrost Model Size LHE6 450 Capacity BTUH /watts Fan Data 'r320'_ 51." Standard Motor Data Defrost Heaters Multiply Capacity By 1.15 Total Am .s 1.00 Total Am 9 0.80 208- 230/1/60 460/1/60 460 /3 /60 2.6 575 /3/60 • 1.8 Watts 9900 208.23 /3/60 27,5 460 /3/60 13.9 575 /3/60 11.1 10 -20 ° F SST 45000 19200 Standard CFM / m 9400 16000 No. 2 Dia. AirThrow (Ft lm) HP Ea. 6 1/2+ Wired 1 • hese FPI MODELS 6.4 Wired 3 • hase - 208 -230 /3/60 • 5.2 Wired 1 . hese 3.4 Wired 3 .hase - InJmm 24 610 Std 70 21 w /Collar 85 26 1HE6 550 55000 9000 2 24 70 85 1/2+ 6.4 - 5.2 3.4 - 2.6 1.8 9900 27,5 13.9 11.1 16100 15300 610 21 26 LHE6 640 64000 13200 3 24 70 85 1/2+ - 5.5 7.8 - 3.0 3.9 2.7 12900 35,8 181 14.5 18700 22400 610 21 26 LHE6 740 74000 12600 3 24 70 85 1/2+ - 5.5 7.8 - 3.0 3.9 2.7 12900 35.8 18.1 14.5 21700 21400 610 21 26 LHE6 810 81000 17600 4 24 70 85 1/2+ - 8.7 10.4 - 4.7 5.2 3.6 17050 47.8 24.3 19.1 23700 29900 610 21 26 LHE6 950 95000 16800 4 24 70 85 1/2+ - 8.7 10.4 - 4.7 5.2 3.6 17050 47.8 24.3 19.1 27800 28600 610 21 26 LHE6 1020 102000 21900 3 30 100 115 1 - - 13.8 - - 6.9 7.8 21400 64.2 32.1 22.8 29900 37200 762 30 35 LHE81200 120000 20700 3 30- 100 115 1 - - 13.8 - - 6.9 7.8 21400 64.2 32.1 22.8 35100 35200 762 30 95 LHE81390 139000 24300 3 30 100 115 1-1/2 - - 19.8 - - 9.9 7.8 21400 64.2 32.1 22.8 40700 41300 762 30 35 LHE81650 165000 26550 3 30 120 140 1-1/2 - - 21.0 - - 10.5 8,4 37100 95.6 47.8 38.2 48300 45100 762 37 43 LHE62120 212000 35400 4 30 120 140 1-1/2 - - 28.0 - - 14.0 11.2 49600 128.4 70.0 56.0 62100 60200 762 37 43 a FPI MODELS LHL4400 40000 9800 2 24 70 85 1/2+ 6.4 - 5.2 3.4 - 2.6 1.8 9900 27.5 13.9 11.1 11700 16700 610 21 26 LHL4 480 48000 9400 2 24 70 85 1/2+ 6.4 - 5.2 3.4 - 2.6 1.8 9900 27.5 13.9 11.1 14100 16000 610 21 26 LHL4 560 56000 13800 3 24 70 85 1/2+ - 5.5 7.8 - 3.0 3.9 2.7 12900 35.8 18.1 14.5 16400 23500 610 21 26 - LHL4650 65000 13200 3 24 70 85 1/2+ - 5.5 7.8 - 3.0 3.9 2.7 12900 35.8 18.1 14.5 19000 22400 610 21 26 LHL4 710 71000 18400 4 24 70 85 1/2+ - 8.7 10.4 - 4.7 5.2 3.6 17050 47.8 24.3 19.1 20800 31300 610 21 26 LHL4 840 84000 17600 4 24 70 85 1/2+ - 8.7 10.4 - 4.7 5.2 3.6 17050 47.8 24.3 19.1 24600 29900 610 21 26 LHL4 890 89000 22800 3 30 100 115 1 - - 13.8 - - 6.9 7.8 21400 64.2 32.1 22.8 26100 38800 762 30 35 LHL41050 105000 21600 3 30 100 115 1 - - 13.8 - - 6.9 7.8 21400 64,2 32.1 22.8 30600 36700 762 30 35 LHL41220 122000 25200 3 30 100 115 1 -1/2 - - 19.8 - - 9.9 7.8 21400 64.2 32.1 22.8 35700 42800 762 30 35 LHL41440 144000 27600 3 30 120 140 1 -1/2 - - 21.0 - - 10.5 Q.4. 37100 95.6 47.8 38.2 42200 46900 762 37 43 QF TOltv`JIIA LHL4 1860 186000 38800 4 30 120 • 140 1 -1/2 - - 28.0 - t -Mil )R41tO11.2 49600 128.4 70.0 56.0 54500 62800 762 37 43 Saturated Suction Temperature °F +20 -10 'r320'_ 51." '- =30 -40 Multiply Capacity By 1.15 1.04 1.00 0.90 0.80 Electric Defrost Capacity & Electrical Data - 60Hz. + 208 - 230/3/60 and 460/3/60 motors are 3/4 HP. Capacity Correction Factors for Electric and Hot Gas Defrost Units 'j;ti C.J Electric Defrost Model Size No. of Fans Connections (Inches) Approx. Net Wt. Lbs / kg Coil Inlet Suction External Equalizer Drain 6 FPI MODELS 450 2 1 -3/8 ODF 1 -5/8 ODF ' 1/4 ODF 1 -1/4 FPT • 280 130 550 2 1 -3/8 ODF 1 -5/8 ODF 1/4 ODF 1 -1/4 FPT 310 140 640 3 1 -3/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT 405 180 740 3 1 -5/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT ' 445 200 810 4 1 -3/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT 535 240 950 4 1 -5/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT 585 270 1020 3 1 -5/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT 753 340 1200 3 - 1 -5/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT 815 370 1390 3 1 -3/8 ODF (2 conns) 2 -1/8 ODF (2 conns) 1/4 ODF (2 conns) 1 -1/4 FPT 865 390 1650 3 1 -3/8 ODF 2 -5/8 ODF 1/4 ODF 1 -1/4 FPT 1175 530 2120 4 1-3/8 ODF 2 -5/8 ODF 1/4 ODF 1 -1/4 FPT 1620 730 4 FPI MODELS 400 2 1 -3/8 ODF 1 -5/8 ODF 1/4 ODF 1 -1/4 FPT 277 130 480 2 1 -3/8 ODF 1 -5/8 ODF 1/4 ODF 1 -1/4 FPT 306 140 560 3 1 -3/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT 400 180 650 3 1 -5/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT . 440 200 710 4 1 -3/8 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT 528 240 840 4 1 -5/8 ODF 2 -1/8 ODF 1/4 ODF 1-1/4 FPT 578 260 890 3 1 -5/8 ODF 2 -1 /8 ODF 1/4 ODF 1 -1/4 FPT 744 340 1050 3 1 -5 /6 ODF 2 -1/8 ODF 1/4 ODF 1 -1/4 FPT 805 370 1220 3 1 -3/8 ODF (2 conns) 2 -1/8 ODF (2 conns) 1/4 ODF (2 conns) 1 -1/4 FPT 854 390 1440 3 1 -3/8 ODF 2 -5/8 ODF 1/4 ODF 1 -1/4 FPT 1160 530 1860 4 1 -3/8 ODF 2 -5/8 ODF 1/4 ODF 1 -1/4 FPT 1600 730 .Physical Specifications - Electric Defrost CITY PNRU�' }tV APPROVED JUN 10 2 �� t':':Jlt: -• Alf Defrost Models Electric & Hot Gas Defrost Models Dimensions (In I mm) 6 FPI 6 FPI 4 FPI Figure A B C F G 520 450 400 1 83 3/32 2111 68 1/8 1730 — — 37 3/16 945 40 11/32 1025 830 550 480 1 83 3/32 2111 68 1/8 1730 — — 37 3/16 945 40 11/32 .. 1025 750 640 560 1 105 5/32 2671 90 3/16 2291 45 3/32 1145 37 3/16 945 40 11/32 ' 1025 850 740 650 1 105 5/32 2671 90 3/16 2291 45 3/32 1145 37 3/16 945 40 11/32 1025 930 • 810 710 1 135 7/32 3435 120 1/4 3054 60 1/8 1527 37 3/16 945 40 11/32 1025 1100 950 840 1 135 7/32 3435 120 1/4 3054 60 1/8 1527 37 3/16 945 40 11/32 1025 Dimensions Fiaure 1. -.— 26 I/4 —► I - I— 24 1 /4 -4.- r D T I 4 9 /ie +► ,4-- 21 5 /31 - 0-1 29 1 /x -4 ► c A B 1 1 CM OF TOW A4WR0 JUN 10 2.11cill AS 5;,) I EU RUSSELL REFRIGERATED ROOM LOAD ANALYSIS QUOTATION: JOB NAME: Freezer CUSTOMER: Company: S & P Meats Address: Phone: QUOTED BY: Company: Address: Phone: CALCULATED RESULTS: Surface Loads: Product Loads: Air Change Loads: Misc. Loads: Daily Total Load: COMMENTS: 221 South Berry Street, Brea CA 92822 -1030. Phone: 714- 529 -1935 Fax: 714 - 529 -7203 Wyatt Refrigeration Co. 12432 Highway 99 S. #75 425.743.7744 ROOM DESCRIPTION: Dimensions: Refrigerated Room Temp: THICKNESS Wall #1 (N): 4 Wall #2 (E): 4 Wall #3 (S): 4 Wall 4 Ceiling: 4 Floor: 4 PRODUCT LOADS: -- COMPUTER ESTIMATED OPTION Estimated useage factor: Heavy Duty Length: 0 °F MISCELLANEOUS LOADS: Personnel: 1 Lighting: Motor HP: 0 Misc. Loads: 242,194 153,041 79,996 89,524 564,754 TOTAL CALCULATED REQUIREMENT: EQUIPMENT: Number of systems: Capacity per System: BTUH System T.D.: °F Price Each Sys: Warranty Price Each: Freight Allowed: DATE: LOCATION: 31 ft Width: Ambient Temp: INSULATION Urethane Urethane Urethane Urethane Urethane Styrofoam Contact: City /State /Zip: Tukwila / WA Fax: Contact: City/State /Zip: Fax: AIR CHANGE LOAD: Infiltrating Air Temp: 84 °F dry bulb and 69 °F wet bulb at 1 times ASHRAE standard.. BTU /24 Hrs. BTU /24 Hrs. BTU /24 Hrs. BTU /24 Hrs. BTU /24 Hrs. 1 watts /sq. ft. 0 BTUH 22 ft Height: 11 ft 95 °F Glass Doors: 0 34,513 BTUH AT 18 HOURS PER DAY RUNTIME. 02/18/04 System Model Number System Voltage: Calculated Run Time: Total Price: Total Warranty: Justin Wyatt Everett / WA 98204 425.355.9314 K FACTOR 0.16 0.16 0.16 0.16 0.16 0.24 Percent of Total: Percent of Total: Percent of Total: Percent of Total: hrs TEMPERATURE 95 95 95 95 110 65 43 % 27 % 14 % 16 % In no event shall Russell be liable for special or consequential damages in connection with the use or output of the Russell Refrigerated Room Load Analysis software. CM OF POW° SIS�a 1 NS 1 ,c) `t3t, • W O O W = . J � N W W O = : H W Z �. I— 0 Z W O • N 0 I— W 'L i : H H lll U = . O t- Z 6 -7 -04 SHUTLER CONSULTING ENGINEERS, INC. Mr. Bill Rambo Building Inspector Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Re: S &P Meats 1024 Andover Parkway East Tukwila, WA Permit #M04 -070 Dear Mr. Rambo, 12503 Bel -Red Road, Suite 100, Bellevue, WA 98005 * (425) 450 -4075 * FAX (425) 450 -4076 I have received a copy of your letter dated May 28, 2004. My responses to the structural items follow: 1. Attached are copies of the calculations and details sheets for this project. 2. The copies of the calculations and details have been wet signed. 3. See revised sheet SKS -2. 4. Mechanical engineer to respond. If you have any further questions or need any additional information, please give me a call. Sincerely, Headland, P.E. Cc: Justin Wyatt, Wyatt Refrigeration CORRECTION LTR #� rl N ,g F T! ull 4 JUN 0 8 2004 pFRMlT cFNTzR Z w 1U 00, coo U) W �. w O; 2 gQ r Z � w U � w W. O iil Z: 6.7 _ O ' ' •Z June 3, 2004 Mr. Justin Wyatt Wyatt Refrigeration Co. 12432 Highway 99 South, #75 Everett, WA 98204 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number M04 -070 S & P Meats —1024 Andover Parkway East Dear Justin: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Planning, Public Works and Fire Departments have no comments. Building Department: Bill Rambo, Building Inspector, at (206) 431 -3679, if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. , If you have any questions, please contact me at (206) 433 -7165. Sincerely, / z CI�t.GCt� Stefa4 Spencer Permit Technician encl xc: File No. M04 -070 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 z 0O N0 . w -J �w. w O, g Q Lo. a �w. z � F-- z r- UO 'O N `. 2. Provide wet seal copies of engineered drawings and calculations. o �! i w Clarify hanger rod diameter and quantity for sheet ASKS -2. F F — .'. The yellow color for dimensions and details is very hard to read and will not show up when ui Z ` we archive the file. Please change to a darker color on the new copies requested above. x 0 z Determination of Completeness Memo Date: May 28, 2004 Project Name: S&P Meats, mechanical permit application Application #: M04-070 Plan Review: Bill Rambo, Building Inspector Tukwila Building Division Bill Rambo, Building Inspector Ext. 1679 The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. 1. Provide the calculations, for the roof mounted condenser, to the drawings submitted as correction letter #1. (Sheets SKS -1 and B /SKS -3) No further comments at this time. May 6, 2004 Dear Justin: Mr. Justin Wyatt 12432 Highway 99 South, #75 Everett, WA 98204 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application # 1 Development Permit Application M04 -070 S & P Meats — 1024 Andover Park East This letter is to inform you that your application received at the City of Tukwila Permit Center on May 5, 2004, is determined to be incomplete. Before your application can continue the plan review process the following items need to be addressed: Building Department: Bill Rambo, at 206 431 -3679, if you have questions concerning the attached memo. Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Sincerely, i'c01LCQi StefaniVSpencer Permjt Technician Enclosures File: Permit File No. M04 -070 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 - 431 -3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M04 -070 PROJECT NAME: S & P MEATS SITE ADDRESS: 102 ANDOVER PARK EAST DATE: 06 -08 -04 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # permit is issued DEPARTMENTS: G 60.. -c Build g ivisi n ❑ Documents /routing slip.doc 2-28-02 Public Works ❑ Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06 -10 -04 Complete d Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route (V Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 07 -08 -04 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [2( Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY DATE: . _.. _.-- ,....�.:-- ,....,.,...,� ,,..,.r..s.wein� u• _ ... ...-» DEPARTMENT : Building Division Public Works APPROVALS OR CORRECTIONS: Documents /routing slip.doc 2 -28 -02 PERMIT COORD COP' PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M04 -070 DATE: 05 -13 -04 PROJECT NAME: S & P MEATS SITE ADDRESS: 1024 ANDOVER PARK EAST X Response to Incomplete Letter # 1 Original Plan Submittal Response to Correction Letter # Revision # after /before permit is issued Fire Prevention Structural ❑ Permit Coordinator Incomplete ❑ REVIEWER'S INITIALS: PERMIT COORD COPY Planning Division DETERMINAT;ON OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -18 -04 Complete Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROOTING: Please Route l Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 06 -15 -04 / Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) E( Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: `- 3- Departments issued corrections: Bldg,l Fire ❑ Ping ❑ PW ❑ Staff Initials: z _1- - ce w aa � J U 0 0 0 . cn CD U.1 0 u. 2 u- ? CD d �w z ± Z0 LU U D co 0 H- ww 0 L O Ill Z i t o 0~ z PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M04 -070 PROJECT NAME: S & P MEATS SITE ADDRESS: 1024 ANDOVER PARK EAST DATE: 05 -05 -04 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPARTM NT : B i ding Division Public Works 0 APPROVALS OR CORRECTIONS: 6 Fire Prevention Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thiy DUE DATE: 05 -06 -04 Complete ❑ Incomplete Comments: Not Applicable ❑ Permit Center Use Only �• INCOMPLETE LETTER MAILED: .� �P - LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: , TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 06 -03 -04 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PERMIT COORD COPY DATE: z w 6 J U 0 11.1 = J I-. CO W w u _ Lo.. I F- al H0 z I- w w V O ON CI I-- ~ H LO z w 0 H O z JUN 03 '04 05:02PM TUKWILA DCD /PW t1 4.0;*:. „ '�7% . .Y• 1: :tire 1 ..t. + d::•� -� — • �' ` } L — •� 'i • Fi � .:•'',. , );A: . (.+ . 4'F:e� o•V; � • Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ? - 0 V ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after/before Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: S & P MEATS Project Address: 1024 ANDOVER PARK EAST Contact Person Justin Wyatt Entered in Sierra on City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Plan Check/Permit Number: M04 -070 P.4 Phone Number (25 - 7 Y3 '71 ( ( ( f g , R l e7 6/4 (,c c/ 06.61c,n-7 AECEIVCD CITY OF TUKWILA JUN 0 2004 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 4/ 06/03/04 Date: 5/13/0`4 Project Name: S & P Meats Project Address: 1024 Andover Park East Contact Person Justin Wyatt Received at the City of Tukwila Permit Center by: ,l Entered in Sierra on City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M04-070 ® Response to incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after/before Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Phone Number ('i) `7q 3:1 `I f4 Summary of Revision: ,A, ) .M s' ' ( rj ► i 0 ,V \ b-) �a m e G C L, n C Cv d E .t •eNv t S . Z Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision 05/06/04 91i6Z -ZE086 VM LNa)I N 3AY. aNZ IZZT cirri XNYdNOJ NOSNKW2i3H 0002/.T1:/T0 3IVQ. 3AI,Losaa3 b00Z /TZ /8O ; rESOO!1DYiL�Ri3H' : TOAD aIva :: dXa # : 'sSI I ZniniaN30 'J NOD ZSNOJ Sit QaaIA02id Sy Q32i3LSIJ32i- S1RLLS114NI QNV JOU\fl IO LN31N.L?lt/d34 'NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. File: M04 -0070 35mm Drawing #1 -3 • PORK BEEF FABRICATION (3eT - Bo BEEF FABRICATION (JRF -5091 STORAGE COOUDe COLO Jan Area of Construction Andover Parkway East SITE PLAN , U 11 11 1111.1 X11 1 1l i11 IIII111 2 Inch 1/16 ��...�. I Site Address: S &PMeats 1024 Andover Parkway East Tukwila, WA 98188 Project Description: Install new 9 HP Condensing Unit on Roof, and matching Air Unit to be installed in existing freezer. Copper tubing will connect Condensing Unit to Air Unit to ro p vide for refrigerant flow. No duct work to be installed. Drawing List: R -1 Title Page R -2 Freezer Floor plan R -3 Refrigeration Equipment Piping R -4 Roof Support Details — Condensing R -5 Roof Support Details — Air Unit By Date Permit No, FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. or �'i[Zff�Lb iii ili iii i1iI � ,i1i �j1 iii iii iii ili ili ili iii iii r11� 3I 1 � I � ( I � 4I 5I g '2 00 SCALE NONE 9L b6 E� ZL L61. �u r . ., , I A ,, k Q ��', 6 ' . }.. 8 L., 9,._.._. §' q. .. i( 6 W3 11 1 1 1111. 1 111�11t. L L1 1. I1111� 1.. h.t J1�1111 . I11111 . Z 1I1aI11.1.1_L1111III . IIalll III ,.. �1111�1111�1LL1�1I11�IIII�I111�ILII�LIIL� LIII��III� lll�lllt�llll� Unit MMMI MTC JSM 127 APRIL 04 r t O frlU� I'1 iy �: ALLUluih,;L pii i L- - L41-:%R PERMIT f L CUIRED FOR: p riECHANICAL I ELECTRICAL 'PLUMBING 11GAS PIPING CITY OF TUKWI LA E! DIVISION THIS DRAWING IS THE PROPERTY OF WYATT REFRIGERATION Ca THE INFORNATION CONTAINED HEREIN SHALL NOT K USED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION of VYATT REFRIGERATION CO. WYA TT REFRIGF TION CO. 12432 HWY 99 SOUTH, UNIT N75, EVERETT, WA 98204 7185) 743 -7744 CLIENT TITLE; F ANA S L P NOots /R -I S & P Meats NNW lo, VA R -1 Title Page MET 1 of 5 ■cv 23'-8' 2 , 86 _4 ( 2 1 ,, 8'- - 3 2 1/ LHE6-550CA Air Unit (In Freezer) 7 '-4 64 Inch 1 1 11 1 1 21 • ' 1/16 31 41 " 51 ' 61 7,4 32' FREEZER (5°F) • LDT0900L6C Condensing Unit (On Roof) 14' 1112" • • 9 1 11 1 11111 9 8 4 1 1111.1-1 1 - 1 1 ,1 1.1111 111 111 1 P 11 - 1 :° Iiiil s 1 8 11(111 . 11111111111111 1' 11111 11 11 3 11 THIS DRAWING IS THE PROPERTY OF" WYATT REFRIGERATION CO. THE INFORMATION CONTAINED HEREIN SHALL NOT IC USED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERNISSION Cr WYATT REFRIGERATION Ca. WYATT REFRIGERATION CO. 12432 HWY 99 SOUTH, UNIT 075, EVERETT, WA 98204 (425) 743-7744 NONE v„. saw Jsv TC 27 APRIL 00 APPIL c __, \\I c:A STA , rA CLIENT; TITLEI TILE IIMP• S & P NOots/R -2 S & P Meats Tukwila. &IA R-2 Floor Plan 1 of 5 pPr 1 3/8" Suction Line LHE6 -550CA Air Unit it " 0 0 a • 1 3/8" Suction Line FREEZER (-5°F) LDT0900L6 Condensing Unit Inch 1/16 I 3 11 1 1 1 1 1 IH . H!1 111 111 1 I11i Iii I , I ILIL ;n- 1llll11I111 2 I 111I II111II1rll1lll 1I1j11111 111 - 1 - 1 I I I I 1HI I 4I 5I I 6 y1, >f 5 1. b 6 E1 Z i. L 6p, „' A �.:: 6 .. 8 .;`.: 11 .. L._; iiii�IIIIIIILiitiiiI IiiiIihilly iiiiliiiiIiiiiliiii LIIIIII II III! ... IIIIIIII iIIILII1IIII IIIII�illllllll I , IIII I. III I THIS DRAWING IS THE PROPERTY OF WYATT REFRIGERATION CO. TIE INFORMATION CONTAINED HEREIN SHALL; NOT DE USED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VYATT REFRIGERATION CO. WYATT REFRIGERATION CO 12432 HWY 99 SOUTH, UNIT 1175, EVERETT, VA 98204 (425) 743 -7744 NAM I MANN NONE JSY MTC 27 APRIL 04 J01 I A CLIENT. TITLE. rI►c MAIL S a P Meats /R -2 S & P Meats ruing lo, YA R -3 Equipment Piping 1 of 5