Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M04-140 - SOUTHCENTER MALL - APPLE COMPUTER
APPLE COMPUTER .,sotrH(E■TrrER mALL. • .1 • Parcel No.: Address: Suite No: doc: IMC- Permit City o Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us 2623049004 733 SOUTHCENTER MALL TUKW Tenant: Name: APPLE COMPUTER Address: 733 SOUTHCENTER MALL, TUKWILA WA Owner: Name: 3G SOUTHCENTER LTD Address: 25425 CENTER RIDGE RD, CLEVELAND OH Contact Person: Name: KEVIN ANWAY Address: 7717 DETROIT AV SW, SEATTLE WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983, SEATTLE, WA Contractor License No: MACDOFS980RU DESCRIPTION OF WORK: INSTALLING NEW 7 -1/2 TON SPLIT SYSTEM WITH FIRE SMOKE DETECTOR; ADDING ONE EXHAUST FAN; ADDING ONE EXHAUST GRILL; ADDING 20 DIFFUSERS; REFRIGERATION PIPING, ASSOCIATED DUCT WORK AND AIR BALANCE; ONE RELIEF HOOD, 1 INTAKE HOOD AND 1 ECONOMIZER. Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 1 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 1 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: Value of Mechanical: $20,826.00 Fees Collected: $396.35 Type of Fire Protection: SPRINKLERS International Mechanical Code Edition: 2003 EQUIPMENT TYPE AND QUANTITY Phone: Phone: 206 768 -4102 Phone: Expiration Date:12 /31/2004 Steven M. Mullet, Mayor Steve Lancaster, Director M04 -140 08/13/2004 02/09/2005 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M04 -140 Printed: 08 -13 -2004 Permit Center Authorized Signature: Print Name doc: IMC- Permit City (;:Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.wa.us Permit Number: M04 -140 Issue Date: 08/13/2004 Permit Expires On: 02/09/ 2005 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or lo l laws regulating construction or the performapce of work. I am authorized to sign and obtain this mechanical permit. Signatur C � ll \ \ MC6 1 L_S — ir Date: Steven M. Mullet, Mayor Steve Lancaster, Director This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M04 -140 Printed: 08 -13 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049004 Permit Number: M04-140 Address: 733 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 07/26/2004 Tenant: APPLE COMPUTER Issue Date: 08/13/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) doc: Conditions M04 -140 Printed: 08 -13 -2004 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Local U.L. central station supervision is required. (City Ordinance #2051) 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** M04 -140 Printed: 08 -13 -2004 Signature: City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: S \ ' 1 S rct Date: doc: Conditions M04 -140 Printed: 08 -13 -2004 i -7 King Co Assessor's Tax No.: ZIP Z 3 0LI 9 00 i Site Address: S 0 t.--4k4". c.e."-t-e ,./ M pa 1 Suite Number: Rzinicr r: Tenant Name: A l e ton-y 04-.o, New Tenant: tl,,... :s ❑ ..No Cily State [40 Name: ke..ti l n Mailing Address: CITY•OF TUKWILA Community DevelopmentJepartment Public Works Departmer Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Company Name: Mailing Address: Company Name: p NGY1 FL QF;R CO • • tpainiu pinUcc ct wngettpermit Application (7 -2004) iqr w C,-} City State Zip Fax Number: (Zoc.) - 7401C - 910 "g E -Mail Address: key .. 11-nwgt. e M04ev.�llrty , Go v- Page 1 Day Telephone: L 20 (.0) - 74A - SF! O Z C IS - 01Y Zip :.,;.: < ter;,:; •.:,. II�1 ( lYl echanicafC ontraetorrinforMation an :back:page S h 0..t,.3vv.u+ M � c J C to n S +r u 04 0 n n^ [� 5 •O 'Ci c.rr- l s q i /" LA.IL � O C'! - car> A l /, 1119 cit State Zip Contact Person: K Q.vi ., Pt n w e`^1 Day Telephone:('Zo4.) - 7th- 1) ID .2.. E -Mail Address: Fax Number: Z2-06) Sf - 4 / Ca3 Contractor Registration Number: MF C ) 0 F S `l 43 0 eu Expiration Date: 2 // o `i * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: 1! platis,.tnust be. w.et:stamped by Engip'eerrof:Record State Company Name: N, A Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser - g.o 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat ' 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Z Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency • Generator Air Handling Unit <10,000 CFM 6 w 1 Incinerator - Comm/Ind Other Mechanical Equipment MECHANICAL CONTRACTOR INFORMATION Company Name: YV1. Mc_Q )roc. - -- A t I tin/ Mailing Address: - 1 1 "1 7)4,4-,,- �r-t Contact Person: �ot., E -Mail Address: Contractor Registration Number: (1/1 C.O o S 113 t) ftI Expiration Date: 12/ 3 / ! o y * *An original or notarized copy of current Washington State Contractor License must be presented at the timdof permit issuance ** Valuation of Project (contractor's bid price): S C S 2 (o Scope of Work (please provide detailed information): i 15 #All new ' t /4- - 1t\ ' Sp l 6- - s S fr M uo I � e s "^ 0 L A:4 c4 � R'J c� 1 .exit opt, s - , Asir le xl'..o.t, i 4- r► U o 4 d J 2O of t P�..V.-e-ra* Ys • er c i o-1 Q l e 1 As 5 ar-4e.�1 -& cL .0 c L, v - k 0,-. Gk. ICI - 6.4 0." cs I ✓ f e . f ❑ Use: Residential: New .... ❑ Replacement Commercial: New . Replacement ❑ Fuel Type: Electric 15t Gas _12 Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject . to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signatur %permits pktstice chan{eslpemdt application (7.2004) AUTHORIZED AGENT: Print Name: LL Mailing Address: - 1 - 1 / "1 D -e-kry ,-`. Page 4 S-c9 t.� t4 �81 City State Zip Day Telephone: ) '1(o $ - ( 4/ b 2 Fax Number: (....z-± - 1(oQ - S/ Day Telephone: ( fa )f e2:? state Zip City Date: �- z6 — off Date Application Accepted: 17 -- o5 1 Date Application Expires: I Staff Initials: City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2623049004 Permit Number: M04-140 Address: 733 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/26/2004 Applicant: APPLE COMPUTER Issue Date: Receipt No.: R04 -00952 Payment Amount: 396.35 Initials: SKS Payment Date: 07/26/2004 03:49 PM User ID: 1165 Balance: $0.00 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 964861 396.35 ACCOUNT ITEM LIST: Description doc: Receipt MECHANICAL - NONRES ° PLAN CHECK - NONRES Account Code Current Pmts 000/322.100 323.08 000/345.830 73.27 Total: 396.35 to.31.14 07/27 9716 TOTAL - 396.35 Printed: 07 -26 -2004 • Pr t: i �u I Type of Insp qn Date Ca 10 icin Addr es : -? S . . Mai( " Special Instructions: � 1 � Date Wanted: a: m. D / n�- Requester: � n' n,^ P ne No: (/ ke i?> 5,4ir `-t INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 i 4 COMMENTS: Approved per applicable codes. L Corrections required prior to approval. $47.00 EINSPECTION EE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: :::�v' Type of lI ectio .•bate Called: Special Instructions` : Date Wanted: Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTIOWNO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PE 206 431 -3670 Corrections required prior to approval. 2 / A,a /atii,ry7 u7 $47.00 REINSPECTI(hN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: / � �� Type of /Inss eection / f, Address: �+ / v, mfr �� Date Called: Spe Instructions. Date Wante Requester: Phone No: • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: (inspector: JaAAE 47,40)...1 !Date: U $47.00 REINSPECTIO1(FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Pr ect: Cole, ✓iii Type o ,f spection: / i Type - 7 — E ; J � �j A s : eze, Date Cal Special Instructions: Date Wed / � a.m. �! P.m. Requester :�� Phone No: (�0Ot CS 3/O, roved per applicable codes. PP P PP to a J • PP rova Corrections required prior q P COMMENTS: v;tre t c1 o 3 - 7 S 1 s s •. 7 INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 3670 Inspector: Date $47. REINSPECTION FEE REQUIRED. Prid"r to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: r Pro• ct: i 0 r l � Type of Insp tion: ■ v � — n AdH pis:f '"p ] r Calle S ci I ructions: Date Wanted: P-7/U J `g p.m. Requester: Phone N � U i I r — l �k W ID3 INSPECTION RECORD Retain a copy with permit INSPECT NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per appliEable codes. El Corrections required prior to approval. COMMENTS: S► ��� L ��1� -- 9 �"1 T� El $47. REINSPECTI • FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: Date: {{i ACTIVITY NUMBER: M04 -140 DATE: 07 -26 -04 PROJECT NAME: APPLE COMPUTER SITE ADDRESS: 733 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # _ Revision # after /before permit is issued DEP RTMENT : Builds g Division Public Works DETERMINA ON OF COMPLETENESS: (Tues., Thurs.) 11 ? Complete Documents/routing slip.doc 2-28-02 PERMIT COORD COP\ PLAN REVIEW /ROUTING SLIP 41/ RWt 1 Prevention Structural ❑ Incomplete REVIEWER'S INITIALS: PERMIT COORD COPY Planning Division Permit Coordinator Not Applicable �a DUE DATE: 0704 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -24 -04 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: F625-052-000 0197} REGISTERED AS PROVIDED BY LAW AS CONST CONT. GENERAL . ' * • • '•• • dts....2::-;110.fP:11,43q134TV.A.: Pig$ gOOt...::$1i01200#000.1.2111/. ' 1.-.12 P 1 /. 2 9 2 • ilI1%CDONALD/MIT40i INC: PO a0X.47983 • SEATTLE WA .98106 Detach And Display Certificate REGISTERED *AS .PROVIDED BY LAW AS • .CQNSTc.ICPNT• . ..r.GENERAL . .. Please Remove REGIST . # .. ::,EXP .. DA And Sign :mi4.1;;I..: MACDOFS980R.U. .12/31 /200 1,;* Idencation ..gt:MTiyt DATE •• ..1...).2f.W.2130 Card Before MiLcDoNAttilikaLER I NC. Placing In PO BOX • 479fa • • • • ; :". . , . Billfold SEATTLE - WA: pb.10.6 .• . ... .. . Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES /002,01-t/ ,(,//4/; >to' a eej,. f • OrfoiaJ 206 763 -9400 City of Tbkwila, Washington MS [lNIES LOCc.INSG Construction TELEPHONE NATURE OF BUSINESS LICENSEE AGREES TO COMPLY WITH AU. THE REQUIREMENTS OF CITY ORDI- NANCES AND STATE LAWS APPLICABLE TO THE BUSINESS ACTIVITY LICENSED HEREUNDER. Please note the following guidelines In the operation of your business: MacDonald Miller Facil. Sol. 0 PO BOX 47983 SEATTLE WA 98146 -7983 EXPIRATION DATE 12 -31 -2004 DATE ISSUED LICENSE NUMBER 12/22/2003 04 -085 FEE PAID SALES TAX CODE $50.00 No.1729 This license is to be displayed conspicuously at the location of business and is not transferable or assignable. 1. It is necessary to contact the City Clerk's Office at 206 - 433 -1800 in the event your business: • Moves within the city limits of Tukwila • Moves outside the city limits • Ceases operation • Changes ownership • Changes use or type of operation • Will be having a special event (such as a tent sale, parking lot sale or any other event) outside its routine operation. 2. Additional licenses are required if your business has live music /entertainment, tow trucks, amusement devices, solicitors /peddlers, or adult entertainment. 3. Any retail sales tax generated in Tukwila needs to be reported to the Washington State Department of Revenue, under sales tax code # 1729. 4. Tukwila business license renewals are mailed to all licensed businesses in December and payable without penalty until January 31. MARK MAKE MODEL CFM TSP FRPM HP V /PH WT.(LBs) SERVICE NOTES EF -1 GREENHECK GB -070 150 0.5" 1,235 1/6 120/10 30 1 TOILET ROOM 00 510 76/64 MARK MAKE MODEL NO. CFM TSP MIN OSA EAT DB W: SENS. MBH TOTAL M : H ELECT. HTR. KW HTG. CAP BT H MCA MOCP PH V/PH/HZ / HZ WT. (LBs) LOCATION NOTES FC -1 TRANE TWE090 3,300 0.45" 510 76/64 64.4 84.8 11.25 55.0 46 50 208/30/60 370 STOCK 000 O MARK MAKE I MODEL NO. TON EER COP V /PH /H7. MCA I MOCP NET WT.(LBs) SERVE D ( INCHES LOCATION NOTES HP -1 TRANE TWA090 _ 7.5 _ 10.1 _ 3.3 208/30/60 35.6 1 60 _ 345 FC -1 38.75 "x41.125 "x34" ROOF 000 MARK MODEL NUMBER MAKE DUTY CONNECT. SIZE FACE SIZE SELECTION NOTES SUPPLY RETURN EXHAUST f CFM MAX.N.C. LEVEL CD -1 PCS TITUS X SEE PLAN 16 "x16" SEE PLAN 30 0®® SG -1 272FS TITUS X SEE PLAN "- SEE PLAN 30 0 RG -1 3FL TITUS i X SEE PLAN `-- SEE PLAN 30 0 LD -A SEE ARCH. x X SEE PLAN 8 "x48" SEE PLAN 30 0 CR- 1 PAR 1 TITUS X ! X SEE PLAN 16 "x16" SEE PLAN 30 00® I - 1 1 - - 1 rail COPT _ t SECTION 15500 - }IEATiNG. VENTILATING AND AIR CONDITIONING 1.00 - GENERAL 1.01 DESCRIPTION OF WORK Furnish and install complete and operative HVAC system as shown on the drawing and specified herein. Work shall include, but net be limited to the following: A. AC units, see schedules. B. Toilet exhaust fans. C. Automatic temperature controls system including time dock, by -pass timer, thermostats. control low - voltage interlock wiring and other associated devices. D. Ductwork and air distribution systems. E. Hangers and supports for ductwork, piping and HVAC equipment F. Flashing of duct and pipe penetrations through exterior openings. G. Roof curb and roof sleeper supports. H. Duct Thermal and Acoustic Insulation. I. License, Permits and associated fees. J. Seismic restraints and bracing. K. Kitchen exhaust and ventilation systems and makeup oir systems. L. Grease duct and fire rated enclousure. M. Duct Smoke Detectors for all HVAC equipment (new and existing) as required by local codes. N. Refrigerant Piping 1.02 RELATED WORK INCLUDED UNDER OTHER SECTIONS A. Fire Protection, Section 15300. B. Plumbing, Section 15400. C. Testing and Boloncing Section 15990. D. Line Vdtoge and Power Wiring, Electrical Section 16000. 1.03 EXAMINATION OF SiTE Visit site before submitting bid and the location of all existing conditions which will affect this work, verify dimensions and locations shown on drowings and cover dl costs. Contractor shill assume reasonable variations or minor omissions and shdl complete proposed work without odditiond cost. Failure to visit site wit not lessen respanslb ity or entitle odditiond compensation for work not included in proposal. 1.04 DRAWINGS The occomponying drawings shall be considered part of these specifications. Work and materials shown on the drawings and not mentioned in the specifications and vice verso shall be executed os if specifically mentioned or shown in both. The drawings shdl be considered as schematic in nature and minor modifications of the work to comply with the structure os found shill be mode. 1.05 RULES AND REGULATIONS A. All work and moterid shall be in full accordance with the latest ides and regulations of the State Fre Morshd and other applicable State and Iocd rules and regulations. Nothing in these drawings or specifications shdl be construed to permit work not conforming to these codes. B. Furnish without any extra charge any odditiond moterid and labor when required to comply with these lows, ordinances and codes regardless of whether shown or mentioned in these specifications or drawings. • HEAT PUMP (OUTDOOR UNR) NOTES: NOTES: O SINGLE CIRCUIT HEAT PUMP UN;T ® LEVEL SLEEPERS BY GENERAL CONTRACTOR Q LOW AMBIENT CONTROL FAN COIL UNIT O VIBRATION ISOLATION SUSPENSION PACKAGE 02 PROGRAMMABLE THERMOSTAT ® SINGLE POINT ELECTRICAL CONNECTION (ELECTRIC HTR) Q ECONOMIZER EXHAUST FAN (ROOF MOUNTED - DOWNBLAST) NOTES: 0 WALL SWITCH 0 ROOF CURB AIR DISTRIBUTION DEVICES NOTES: (i) COORDINATE FINISH WITH ARCHITECT Q COORDINATE EXACT LOCATION OF DIFFUSER WITH ARCHITECTURAL REFLECTED CEIUNG PLAN 0 PERFORATED STAINLESS STEEL ARCHITECTURAL PANEL • FIRE DAMPER SEPARATE MOQT REQ1MtED FOR: O Mdw d flEfflc& ef Plumbing • Gn NOV aty BUILDING DIVISION 1.06 SUBMITTALS Submit for review io Architect a complete and all-inclusive list of equipment and materials proposed for use (6 copies), occomponied by manufacturer's data sheets. Data shall be forwarded in a single package within 15 days after award of contract. Submit six blueline prints and one reproducible shop drawing showing proposed ductwork installation. Include sizes, locations and other required information to coordinate installation with other trades. 1.07 AS -BUILT DRAWINGS A set of HVAC Prints will be furnished to the Contractor on which he shall indicate the Installation - as-built' as the work progresses. Upon completion of the work, a set or reproducible drawings shill be obtained from Architect at cost, and all changes as noted on the record set of prints shdl be incorporated thereon. This set of reproducibles, along with one set of blueprints, shall be delivered to Noah's upon completion and before find acceptance of the project. 1.08 GUARANTEE The Contractor shall leave the entire installation in complete working order free from any defective material, workmanship or finish. He shall guarantee to repair or reploce, without charge, defects due to faulty workmanship or material for o period of one year from the date of fling of the Notice of Completion. 1.09 OPERATION MANUALS AND OWNER INSTRUCTIONS A. Provide complete operation and maintenance manuals cowing all mechanical systems and equipment that hove been installed. Three (3) copies of the manual shdl be bound in hardback binders. B. Provide instructions to owner as to operation of all HVAC equipment. Instruction period to commence for minimum of (2) hours and shall be scheduled at owner's convenience. 1.10 CUTTING AND PATCHING A. The contractor shall do all cutting, drilling and patching which may be required for the installation of the work under this Section of the Specifications. B. Patching shall be of the some workmanship, material, and finish and shdl match occuratdy dl surrounding construction in o manner satisfactory to Architect. No cutting of the structure shdl be permitted without written approval of Architect. 2.00 - PRODUCTS 2.01 DUCTWORK Shall be as specified in the following schedules. Materials shoN be dearly stamped or marked with grades and gouges. A. Sheet metal rectangular ductwork, plenums and cog construction shall be in strict accordance with the HVAC Duct Construction Standards - Metal and Fkxble, and the Sheet Metal Construction For Ventiloting /Air Conditioning Systems, latest edition os issued by SMACNA and ASHRAE respectively. B. Sheet metd round: Shall be United Sheet Metal, or approved equal, spiral "Unised' with Uniform" fittings, machine formed. C. Materials for ductwork shall be galvanized steel, of gages shown m the SMACNA HVAC Duct Construction Standards. All ductwork shill be constructed in occordonce with the pressure - velocity classification standards no less than +/- 2' WG and duct sealing requirements of Class C (minimum). 0. Flexble ductwork shall be pre - insulated low pressure type (rated to 4" w.P.) with vapor barrier. Ducts shall meet Class 1 requirements of NFPA 90A and shill be labeled by LI.L. flexible ducts shall be Genflex, PNL(s) or approved equal. Flexible duct is allowed only at find connections to or distribution fixtures at lengths of six feet maximum. E. Unless shown otherwise, al insulation shah be external to ductwork. MECHANICAL EQUIPMENT SCHEDULE J 44*-49P Prn 'WSW appvral Is subject to errors and =Jim /lppovd of aonsfnutlon doainienes does not aulllMOa the violation of any adopted code or ordnance. Irolat of approved Reid Copy and .. . .. is acknowledged: My of 71ikwNs / BUILDING DIVISION /.. MECHANICAL SPECIFICATIONS F. All kitchen ventilation duct installation and design shall conform to UBC Section 2002 and Section 2003, UBC, NFPA 96 and other local code requirements. Grease ducts shall be constructed of not less than 0.055 inch(16 gouge) galvanized steel or stainless steel at least 0.044 inch in thickness. Joints and seams shall be mode with o continuous liquid -tight weld or braze mode on the external surface of the duct system. Duct bracing and supports shall be mode of non - combustible materials. Bolts and other mechanical fasteners shall not penetrate the duct walls. 2.02 DUCTWORK ACCESSORIES A. Damper Operators 1. Ducts with external insulation: Ventlock /637, DuroDyne, Young, or approved equal. 2. Ducts with internal insulation and /or no insulation: Ventlock 1635, DuraDyne, Young, or approved equal. B. Flexible Connections; Ventfabrics "Ventglas ", DuraDyne, or approved equal, U.L approved with metal attachment. C. Air Extractor. Titus AG- 225, Krueger EX -88C, or approved equal. D. Turning Vanes shall comply with SMACNA HVAC Duct Construction Standards All rectangular duct with mitered elbows shall be fitted with turning canes. E. Spin -In- Fittings are not allowed. Use United McGill Bellmouth fitting for round duct taps. F. Support ductwork according to the SMACNA Duct Construction Standards and the drawings. G. Access Doors In Ductwork Shall be Ventlocc, Duc4tmote or approved equal, stomped or formed insulated access doors complete with dI hardware and sealant. H. Joint Selling: 1. The following items are to be sealed with Hordcost DT tape and odhesive o. Longitudinal and transverse seams of rectangular ductwork b. All round fittings and joint connectors use FTA -20 for indoor use and RTA -20 for outdoor use. 2. Flexble duct of diffusers shall use integral stainless steel draw band and pressure sensitive tope, Hordcost P -301 or equal. I. Brocngs, hangers, nuts, etc. shdl be galvanized. J. Curved elbows shdl have centerline radius equal to one and one -half times duct width in plane of turn. K. Square elbows shdl hove tuming vanes. Miter elbows (not square) shall hove splitter vanes 3 inches o.c. L Volume dampers shell be constructed to SMACNA Standards and shall be Young Regulator model 4040 for round ducts and series 820 for rectangular ducts 2.03 AIR DEVICES Diffusers, Grilles and Registers: Titus, Krueger, Metal*Aire, or Acutherm Thermafuser where shown. Furnished and installed by Mechanical Contractor. Provide volume dampers and point interior Not block. Size, finish, home types and accessories os shown on the drawings. 2.04 FiRE DAMPERS & SMOKE FiRE DAMPERS A. Provide fire dampers with access doors installed where required by all local codes. In general, fire dampers are required where ducts pierce fve -rated floors, ceilings, walls and shafts. Refer to Architectural drawings far locations of dl fire rated assemblies. B. Fie dampers shall be Ruskin or equal os approved by tondard for rectangular and round ducts. Dumpers shill meet the requirements for NFPA BuNetin No. 90A, and shall be tested in accordance with UL 555 Test Criteria, fire dornpers shall be labeled and listed by UL C. If applicable, fre demon shall comply with UL -5* -1990, 4th edition and shill be marked or Use in Dynamic Systems or "Far use it Static Systems' os required. • • THIS CONTRACTOR WILL PROVIDE THREE COPIES OF OPERATING MAINTENANCE INSTRUCTIONS AND TESTING /BALANCE REPORT TO THE OWNER (IN VINYL COVER • REFER TO ARCHITECTURAL DRAWINGS FOR FIRE SEPARATIONS. . ALL DUCTS PASSING THROUGH ARE SEPARATIONS SHALL HAVE DAMPERS WHICH CONFORM WITH NFPA STANDARD * 90 SECTION 135 • ACCESS OPENINGS FOR DAMPERS SHALL BE INSTALLED IN DUCTWORK WHEREVER FIRE DAMPERS OCCUR. NOTES INSTALL ALL DUCTWORK AND PIPING TO BEST SUIT FIELD CONDITIONS AND COORDINATE WITH THE INSTALLATION WORK OF OTHER TRADES. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE THE EXACT LOCATION OF SINGLE LINE DUCTS. THIS CONTRACTOR SHALL REFER TO ELECTRICAL CONTRACT DOCUMENTS TO OBTAIN THE INFORMATION OF STARTERS, VOLTAGE, PHASE, INTERLOCKING CONTROLS & MISCELLANEOUS EQUIPMENT SUCH AS RELAYS IN STARTERS, ETC., SO THAT ALL ELECTRICAL EQUIPMENT SHALL FULLY COMPLY WITH ELECTRICAL AND CONTROL REQUIREMENTS. DUCT SIZES WITH LINING SHOWN ARE NET, CLEAR INSIDE DIMENSIONS. 8 . PROVIDE HVAC DUCT INSULATION IN ACCORDANCE WITH SECTION 604 OF THE UNIFORM MECHANICAL CODE 1998. 9. ALL SQUARE ELBOW TURNS IN DUCTWORK SHALL HAVE TURNING VANES. 10. FURNISH AND INSTALL NOISE AND VIBRATION ISOLATION DEVICES ON DUCTWORK AND EQUIPMENT. 11. FLEXIBLE DUCT WORK SHALL NOT BE MORE THAN 6 FEET IN LENGTH FOR ANY ONE APPLICATION, 12. THE EXISTING CONDITIONS SHOWN ON THESE DRAWINGS ARE DEVELOPED FROM FIELD VERIFICATION. THE ENGINEER, HOWEVER, DOES NOT TAKE RESPONSIBIUTY FOR THE COMPLETE ACCURACY OF THE PLANS. THE CONTRACTOR, THEREFORE, SHALL MAKE ALLOWANCES IN HIS BID TO PROVIDE A COMPLETE AND OPERABLE SYSTEM WiTH THE INTENT AS DESCRIBED BY THESE DRAWINGS AND SPECIFICATIONS - MAKING PROVISIONS FOR FIELD ADJUSTMENTS AS REQUIRED. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO START OF WORK OR PRICING. 13. CONTRACTOR SHALL PAY SPECIAL ATTENTION IN SCHEDUUNG CONSTRUCTION TO MINIMIZE DISTURBANCE TO BUILDING OPERATIONS AND "DOWN -TIME" OF HVAC SERVICE. CONTRACTOR SHALL PHASE CONSTRUCTION AND SCHEDULE DEMOLITION AND DISCONNECTION OF VITAL SERVICES AND SHUTDOWN OF EQUIPMENT TO COMPLY WITH OWNER'S INSTRUCTIONS AND REQUIREMENTS. PRIOR TO START OF WORK, CONTRACTOR SHALL COORDINATE WITH OWNER TO IDENTIFY AND PRESENT A CONSTRUCTION SCHEDULE WITH ANTICIPATED "DOWN -TIME" ON SERVICES. No doom Mel he m i le the __ et wank walnut peter approved et Tubas adidimp NOTE: AsOliona el require aa�OA` pin submittal and tnef include additionel paw rekiaw Irma D. Combination Smoke Fire Dampers shall be installed where ductwork penetrates fire rated walls surrounding an exit corridor. E. Combination Smoke Fire dampers shall be Ruskin, Submit cutsheets as required by Landlord for all equipment 2.05 INSULATION (Installed per Manufacturer s Recommendations) A. Heating and Coding Ductwork located in interior locations; Insulate with Owens- Coming • Fberglos dl service Duct Wrap Type 150 with factory applied flame retardant Fol Reinforced Kraft Facing (FRK -25 U.L. labeled), or approved egad. Installed thermal resistance shah be a minimum of 4.2. B. Acoustical Ductwork and Plenum and Casing Liner 1. Provide internally lined ductwork where indicated on drawings. Acoustical duct liner shdl be trdite duct liner, or_equol, matte face, 3 lb. density, 1 thick, suitable for velocities from 1500 to 4000 fpm, in compliance w/ UL723 and UL181. Secure liner to ductwork with adhesive and mechanical fansteners per SMACNA Duct Liner application standard. 2. *ere internal insulation is applied, duct and plenum sizes as shown on the drawings shall be inside dear dimensions. 3. Fberglos duct and plenum insulation are to be applied only with manufacturer's approved odhesives, mastics and mechanical fastening devices. 2.06 TEMPERATURE CONTROL SYSTEM k Contractor shall furnish all necessary control devices (rdoys, contacts, etc.) and shall obtain direction from manufacturer on octud wiring requirements. B. Contractor shdl post in the office typewritten instructions on operation of all controls. 2.07 SEISMIC RESTRAINTS AND BRACING A. All HVAC equipment, ductwork, piping and wiring conduits shah be installed to meet the lateral bracing requirements for the applicable seismic zone. Provide seismic restraints in accordance with Seismic Hazard Level (SHL) A of the "Seismic Restraint Manual: Guidelines for Mechanical Systems' doted 1991, as published by S.M.A.C.N.A. and also in accordance with applicable local buldng codes. 8. All rooftop equipment shall have proper anchoring and restraint systems, and shah be secured to a roof curb, equipment pod or other structurd member to prevent lateral, vertical or overturning movement without sacrificing any resilient vibration isolation requirements. 3.00 INSTALLATION AND EXECUTION 3.01 INSTALLATION REQUIREMENTS A. Ductwork: 1. Duct brunches shill be fitted with volume or splitter damper and where required, extraction damper. MI occessble volume controls shah have locking quadrants. AN inoccessble controls (dampers, etc.) shill be provided with permanent extensions to occessble spaces. Branch volume controls are in addition to volume controls of registers and diffusers. 2. Air inlets, outlets shdl be property set in place. Registers and grilles shall be tightly sealed. N o4u IO • r REVIEWED FOR CODE COMPLIANCE . APPROVED Lola .. 8 2004 q ty Of Tu Wile BUILDING DIVISION SYMBOL m • MECHANICAL LEGEND ABBR. MVD CD CER CRR T'STAT BD So TG CD VTR (E) (N) (R) POC RNA OB0 DESCRIPTION SUPPLY AIR DUCT UP EXHAUST AIR DUCT UP RETURN AIR DUCT UP RETURN /EXHAUST /SUPPLY DUCT MANUAL VOLUME DAMPER EXISTING DUCT FtEXIBIE DUCT, 6' -0" LONG MAX. CEIUNG SUPPLY DIFFUSER CEIUNG EXHAUST REGISTER CEIUNG RETURN REGISTER ACOUSTICALLY INSULATED DUCT THERMOSTAT SENSOR BACKDRAFT DAMPER SMOKE DETECTOR ONE HOUR FiRE DAMPER THREE HOUR FIRE DAMPER COMBINATION FiRE /SMOKE DAMPER TRANSFER GRILLE CONDENSATE DRAIN VENT THRU ROOF EXISTING NEW RELOCATED POINT OF CONNECTION UNDERCUT DOOR ROUND NECK ADAPTER OPPOSED BLADE DAMPER TO BE REMOVED DRAWING SCHEDULE M1.0 MECHANICAL LEGEND, SPECS AND SCHEDULES 142.0 MECHANICAL HVAC PLAN M3.0 MECHANICAL HVAC DETAILS FP1.0 FIRE PROTECTION PLAN & SPECIFICATIONS 3. Transitions in size of ducts shall be mode by uniformly tapering sections having 1 inch increase in width for each 7 inches of run unless construction limitations require o more abrupt transition. 4. Diffusers. Grilles and Registers: Each register and diffuser shall be equipped with o volume dumper or air extractor. Paint interior surface of dl units flat block. Face and trim of dl units shall be finished. Size, finish, frames, accessories, capacity and pattern os shown on drawings. 5. Contractor shall provide manual volume dampers at dl branch ductwork in supply air, return air and outside air systems (whether shown on plans or not) where required for air balancing of HVAC systems. END OF SECTION SECTION 15990 - TESTING. ADJUSTING AND BALANCING 1.00 - GENERAL 1.01 DESCRIPTION The testing and balancing work will be performed under o separate contract from the HVAC work. The work described in this section shall be performed by an independent test and balance agency, specializing in testing and balancing of HVAC systems and a number of the AABC or approved equal organization. 1.02 SCOPE OF =,ORK A. HVAC System Test and Balance in accordance with procedures established by AABC or NEBB. B. Measurement of find operating conditions of HVAC equipment. C. Test and Balance Reports, (4) copies. D. Each piece of air conditioning and heating equipment and the air distributions systems shall be tested and adjusted to insure proper functioning of all control, proper distribution of air, maintenance of temperature, diminution of drafts, noise and vibration, and left in first doss operating condition. The air system shall be rood jested if required for comfort of each room. E. The mechanical contractor will make any changes in the pulleys, belts, dampers, vanes, baffles and the lice required for correct balance of system as recommended bt T&B agency and to the satisfaction of the owner. 1.03 SUBMTT A. The t ALS est and balance report shot, include, as a minimum, but not be limited to: 1. Loch equipment shall be identified by equipment service number, manufacturer, model number, and serial number, motor horsepower, motor nameplate voltage, motor RPM, actual and design static pressure, actual outlet velocity, octud CFM, design CFM. 2. Each coil shdl be identified by equipment service number, manufacturer, model number and size, number of rows, total CFM, air inlet and outlet dry bulb and wet bulb temperatures. 3. Each air outlet shall be identified with manufacture, model number, size, velocity, correction factor, actual CFM, design CFM. 4. Traverse reeding of main supply, return and outside air ducts to establish oir quantities. 5. Test and record temperatures from temperature controllers such as day thermostat, night thermostat. 6. Test and record temperatures from main supply air trunk, mixed air during the MI heating and full cooling cycle and economizer cede. 7. Test and balance economizer. EP40 OF SECTION Fx�+a �•.� O„�" ..PATE; 1 her kli ••;* R 0,? • . Y it . Y + �. j1 . ��' !411 Sril: of i:1:!•$!4 •∎r, 1. • • irL C !4F �t.Ij'•.� Pr ENERGY • CONSERVATION • COMPANY ENCON 4940 El Camino Real Los Altos, California, 94022 tel # (650) 961 -8095 fox • (650) 964 -3754 email infoOencon.com Copyright • ENCON 2004 ENCON Project j: AP4805.00 No. Date Issue 5/26/04 ISSUE FOR PERMIT - 73? SC rtiall T k..Il.+ • U z LU 0 0 U LU C- C- a Store No. R -106 South Center Mall Seattle, Washington PEqti r cr S(s � 2"- 40060 =IF NTS • • MECHANICAL LEGENDS SPECS & SCHEDULES MO M 1.0 r MECHANICAL LEGEND . SYMBOL I ems. � DESCRIPTION MVD SUPPLY AIR DUCT UP EXHAUST AIR DUCT UP RETURN NR DUCT UP RENRN /E)QIAUST /SUPPLY DUCT MANUAL VOLUME DAMPER EXISTING DUCT FUMBLE DUCT, 6' -0' LONG MAX. CD CEILING SUPPLY DIFFUSER CER CERING EXHAUST REGISTER CRR CEIUNG RETURN REGISTER ACOUSTICALLY INSULATED DUCT T'$TAT THERMOSTAT SENSOR _... B I __. BO BMCKORAFT DAMPER SD SMOKE DETECTOR ONE HOUR f1IiE DAMPER THREE HOUR FIRE DAMPER COMBINATION F1RE/SM01(E DAMPER TG TRANSFER GRILLE CD CONDENSATE DRAIN VAR VENT THRU ROOF (E) EXISTING (N) NEW (R) RELOCATED POC POINT OF CONNECTION UNDERCUT DOOR RNA ROUND NECK ADAPTER 080 OPPOSED BLADE DAMPER TO BE REMOVED 6 172nd St 6 172nd PI oT Ia pQ . t.coin, Inc.; ©2004 IiAVTE ti S 152nd St ` S 4 .52nd PI onto .81v h s-1-5T-s-t 6 153rd St *Iris .1' ji4K�(91.1<temo. jL/r Min kler Blvd Corporate Dr S $EC11ON 15500 - HEATING. VENTILATING AND MR CONDITiONINQ 1.00 - GENERAL 1.01 DESCRIPTION OF WORK Furnish and instdl complete and operative HVAC system as shown on the drawing and specified herein. Work shall indude, but not be limited to the following: A. AC units, see schedules. B. Toilet exhaust fans. C. Automatic temperature controls system including time dock, by -pass timer, thermostats, control low - voltage Interlock wiring and other associated devices. 0. Ductwork and oir distribution systems. E. Hangers and supports for ductwork, piping and HVAC equipment F. Flashing of duct and pipe penetrations through exterior openings. C. Roof curb and roof sleeper supports. H. Duct Thermal and Acoustic Insulation. 1. License, Permits and associated fees. J. Seismic restraints and bracing. K. Kitchen exhaust and ventiotion systems and makeup air systems. L Grease duct and fire rated endousure. M. Duct Smoke Detectors for oil HVAC equipment (new and existing) os required by local codes. N. Refrigerant Piping 1.02 RELATED WORK INCLUDED UNDER OTHER SECTIONS A. Fire Protection, Section 15300. B. Plumbing, Section 15400. C. Testing and Balancing Section 15990. D. Line Voltage and Power Wiring, Electrical Section 16000. 1.03 EXAMINATION OF SiTE Visit site before submitting bid and check location of all existing conditions which will affect this work, verify dimensions and locations shown on drawings and cover all costs. Contractor shdl assume reasonable variations or minor omissions and shell complete proposed work without odditiond cost. Failure to visit site will not lessen responsibiity or entitle additional compensation for work not included in proposal. 1.04 DRAWINGS The accompanying drawings sholi be considered port of these specifications. Work and materials shown on the drawings and not mentioned in the specifications and vice verso shah be executed as if specifically mentioned or shown in both. The drawings shdl be considered as schematic in nature and minor modifications of the work to comply with the structure as found show be mode. 1.05 RULES AND REGULATIONS A. All work and materid shall be in full accordance with the latest rules and regulations of the State Fire Morshd and other applicable State and local rules and regulations. Nothing in these drawings or specifications shdl be construed to permit work not conforming to these codes. B. Furnish without ony extra charge any odditiond material and labor when required to comply with these lows, ordinances and codes regardless of whether who or mentioned in these specifications or drawings. HEAT PUMP (OUTDOOR UNIT) MARK HP -1 NOTES: MAKE MODEL NO. TON EER TRANE TWA090 17.5 10.1 3.3 208/30/60 O SINGLE CIRCUIT HEAT PUMP UNIT Q LEVEL SLEEPERS BY GENERAL CONTRACTOR ® LOW AMBIENT CONTROL FAN COIL UNIT MARK FC- 1 MAKE TRANE NOTES: 0 WALL SWITCH Q ROOF CURB MODEL NO. TWE090 CFM 3,300 TSP 0.45" AIR DISThBU11ON DEVKES MIN OSA 510 MECHANICAL EQUIPMENT SCHEDULE COP EAT (DB /WB) 76/64 V /PH /HZ 1 NOTES: 0 VIBRATION ISOLATION SUSPENSION PACKAGE 0 PROGRAMMABLE THERMOSTAT ® SINGLE POINT ELECTRICAL CONNECTION (ELECTRIC ® ECONOMIZER SENS. MBH 64.4 HTR) EXHAUST FAN (ROOF MOUNTED - DOWNBLAST) MCA 35.6 1.06 SUBMITTALS Submit for review to Architect a complete and all- inclusive list of equipment and materiels proposed for use (6 copies), accompanied by manufacturers data sheets. Data shah be forwarded in a single package within 15 days after award of contract. Submit six bluelne prints and one reproducible shop drawing showing proposed ductwork installation. Include sizes, locutions and other required information to coordinate installation with other trades. MBH 84.8 1.07 AS -BUILT DRAWINGS A set of HVAC Prints wii be furnished to the Contractor on which he shall indicate the installotion "as -bust os the work progresses. Upon completion of the work, a set or reproducible drawings shall be obtained from Architect at cost, and all changes as noted on the record set of prints shall be incorporated thereon. This set of reproducbles, along with one set of blueprints, shall be delivered to Noah's upon completion and before find acceptance of the project. 1.08 GUARANTEE The Contractor shall leave the entire installation in complete working order free from any defective material, workmanship or finish. He shall guarantee to repair or replace, without charge, defects due to faulty workmanship or material for a period of one yeor from the date of funk; of the Notice of Completion. 1.09 OPERATION MANUALS AND OWNER INSTRUCTIONS A. Provide complete operation and maintenance manuals covering dl mechanical systems and equipment that hove been installed. Three (3) copies of the manual shill be bound in hardback binders. B. Provide instructions to owner as to operation of dl HVAC equipment. Instruction period to commence for minimum of (2) hours and shall be scheduled at owner's convenience. 1.10 CUTTING AND PATCHING A. The contractor shall do all cutting, driting and patching which may be required for the installation of the work under this Section of the Specifications, B. Patching shall be of the some workmanship, material, and finish and shdl match occuratdy all wounding construction in a manner satisfactory to Architect. No cutting of the structure shall be permitted without written approval of Architect. 2.00 - PRODUCTS 2.01 DUCTWORK Shall be as specified in the following schedules. Materials shall be dearly stamped or marked with grades and gouges. A. Sheet metal rectangular ductwork plenums and cooing construction shale be in strict accordance with the HVAC Duct Construction Standards - Metd and Flexible, and the Sheet Metal Construction For Ventiating /Ar Conditioning Systems, latest edition os issued by SMACNA and ASHRAE respectively. B. Sheet metd round: Shall be United Sheet Metal, or approved equal, spird "Iknisear with Uniform" fittiings machine formed. C. Materials for ductwork shill be galvanized steel, of gauges shown in the SMACNA HVAC Duct Construction Standards. All ductwork shall be constructed in accordance with the pressure - velocity classification standards no less than +/- 2' WG and duct sealing requirements of Coss C (minimum). D. Flexible ductwork shah be pre - insulated low pressure type (rated to 4' WN.P.) with vapor barrier. Ducts shall meet Doss 1 requirements of NFPA 90A and shall be labeled by U.L flexible ducts did be Grnfle; NIL(s) or approved equal• flexible duct is allowed only at find connections to air distribution fixtures of lengths of six feet maximum. E. Unless who otherwise, all insulation show be external to ductwork. MOCP ELECT. HTR.(KW) 11.25 NOTES: 0 COORDINATE FINISH WITH ARCHITECT • COORDINATE EXACT LOCATION OF DIFFUSER WITH ARCHITECTURAL REFLECTED COUNG PLAN Q PERFORATED STAINLESS STEEL ARCHITECTURAL PANEL ® FIRE DAMPER Parcel 262304 -9004 Name WESTFIELD CORP INC Site Address Geo Area 70 -20 Spec Area 250-11 Block NET WT.(LBs 60 1 345 HTG. CAP, (BTUH) 55.0 MCA 46 SERVE FC -1 Parcel Data MOCP 50 H x L x D IN HS 38.75 "x41.125 "x34" V /PH /HZ 208/30/60 Present Use Zoning Jurisdiction Property Type Code Lot WT.(LBs) 370 Code 62 TUC 'TUKWILA C LOCATION ROOF LOCATION STOCK 2.04 FIRE DAMPERS & SMOKE FlRE DAMPERS A. Provide fire dampers with access doors installed where required by all local codes. in ,engird, fire dumpers are required where ducts pierce fire - rated floors, Wings, walls and shafts. Refer to Architecturd drawings for locations of all fin rated assemblies. B. rre dampers shall be Ruskin or equd os approved by Landlord for rectangular and round ducts. Dampers shall meet the requirements for NFPA Bulletin No. 90A, and shd be tested in accordance with UL 555 Test Criteria, fire dampers shall be labeled and listed by UL C. If N fire dormers shall comply and shd be marked Tar Use in teems or " For 4th edition in Static Systems as required. NOTES 0 NOTES MARK EF -1 MAKE GREENHECK MODEL GB -070 CFM 150 TSP 0.5" FRPM 1,235 HP 1/6 V /PH 120/10 WT.(LBs) SERVICE NOTES 30 TOILET ROOM 0 0 MARK CD -1 SG -1 RG -1 LD -A CR--1 MODEL NUMBER PCS 272FS 3FL SEE ARCH. PAR MAKE TITUS TITUS TITUS TITUS DUTY SUPPLY RETURNEXHAUST x x X x x x X CONNECT. SIZE SEE PLAN SEE PLAN SEE PLAN SEE PLAN SEE PLAN FACE SIZE 16 "x16" 8 "x48" 16x16" SELECTION CFM MAX, N.C. LEVEL SEE PLAN SEE PLAN SEE PLAN SEE PLAN SEE PLAN 30 I 30 I 30 30 30 NOTES 000 0 0 000 • Legal Description NW 1/4 OF NE 1/4 LESS STS LESS POR BEG ON E LN THOF 757.03 FT S OF N LN OF SUBD TH N 89 -40-24 W 293.74 FT TH S 00 - 19 - 36 W 154 FT TH S 89-40 -24 E 249.16 FT TH ON CURVE TO LFT HAVING RAD 45 Fr AN ARC DIST 71.10 FT TH N 00- 12-09 W 108.59 FT TO BEG LESS POR BEG S 89 -40-24 E 7 %.84 FT do S 00 -19 -36 W 144 FT FR NW COR OF SD SUBD TH S 89 -40.24 E 230.16 FT TH S 00 -19 -36 W 402 FT TH N 89 -40-24 W 230.16 FT TH N 00 -19 -36 E 402 FT TO BEG LESS POR BEG NW COR OF SUBD TH S 00-19 -36 W 10.83 FT TH S 89 -40-24 E 25 FT TH S 00-19 -36 W 138.17 FT TH S 89 -40-24 E 226 FT TH N 00-19 -36 E 96 Fur TH S 89 -40 -24 E 72 FT TH N 00 -19 -36 E 42.17 FT TH S 89 -40-24 E 7.90 FT TH N 00 -19 -36 E TO N LN TH W TO BEG LESS BEG AT NE COR OF NW 1/4 OF NE 1/4 TH S 941.03 FT TH W 30 FT TO TPOB TH W 250 FT TH S 100 FT TH E 250 FT TH N 100 FT TO TPOB LESS BEG NW COR OF NE 1/4 TH S 00 -19 -36 W 954 FT TO TPOB TH S 89 -40-24 E 120 FT TO POC TH SELY ALG CURVE TO RGT RAD 20 FT CIA 90 -00-00 ARC DIST 31.42 FT TH S 00-19 -36 W 294.45 FT TO POC TH SWLY ALG CURVE TO RGT RAD OF 30 FT C/A 58 -22 -1 I ARC DIST 30.56 TO N MGN S 164 ST TH N 89-30-56 W 116.48 FT TO W LN OP NE 1/4 TH N ALG SD W LN TO TPOB F. All kitchen ventllotion duct installation and design shall conform to UBC Section 2002 and Section 2003, UBC, NFPA 96 and other local cede requirements. Grease ducts shall be constructed of not less than 0.055 inch(16 gouge) galvanized steel or stainless steel at least 0.044 inch in thickness. Joints and seams shall be mode with a continuous liquid - tight weld or braze mode on the external surface of the duct system. Duct bracing and supports shall be mode of non- combustble materials. Bolts and other mechanical fasteners shall not penetrate the duct walls. 2.02 DUCTWORK ACCESSORIES A. Damper Operators 1. Ducts with external insulation: Ventlock X637, DuraDyne, Young, or approved equal. 2. D Du p ct t in ss with t4rnal insulation and /or no insulation: Wedlock #635, DuraDyne, Young, or uol- B. Flexble m U0 " e t a s o = "Vent � as , D raD , or approved equal, U.L. C. Air Extractor: Titus AG -225. Krueger EX -88C, or %probed equal. 0. Turning Vanes shall comply with SMACNA HVAC Duct Construction Standards Al rectangular duct with mitered elbows shall be fitted with turning vanes. E. Spin -h- Fittings are not allowed. Use United McGill Belkmouth fitting for round duct taps, F. Support ductwork according to the SMACNA Duct Construction Standards and the drawings, G. Aecesss D9ors In Ductwork ` ' be VenOodi. e with et4 e re sea Mw a or nee insulated access , H. Joint Sealing: 1. The following items are to be sealed with Hardcost DT tape and odhesive: o. Longitudinal and transverse seams of rectangular ductwork b. All round fittings and joint connectors use FTA -20 for indoor use and RTA -20 for outdoor use. 2. Flexible duct at diffusers shah use integral stainless steel draw band and I. pressure se tape, Hordcost P-301 or equal. gs, hangers, nuts, etc. shah be galvanized. J. c urved elbows shall hove centerline radius equal to one and one -half tines duct width plane of turn. K. Square elbows shaft have turning vane& Miter elbows (not square) shah hove splitter vanes 3 inches o.c. L Volume dampers shall be constructed to SMACNA Standards and shah be Young Regulator model 4040 for round ducts and series 820 for rectangular ducts 2.03 AIR DEVICES Famished and installed b�Mechanied , Metd•Aire, or Acutherm Therrnafuser where shoes. by a or. Provide volume dampers and point interior flat block. Size, finish, frame types and accessories as shown on the drawings. MECHANICAL SPECIFICATIONS 1. 2. 3. 4. REFER TO ARCHITECTURAL DRAWINGS FOR FiRE SEPARATIONS. 5. ALL DUCTS PASSING THROUGH FIRE SEPARATIONS SHALL HAVE DAMPERS WHICH CONFORM WiTH NFPA STANDARD • 90 SECTION 135 6. ACCESS OPENINGS FOR DAMPERS SHALL BE INSTALLED IN DUCTWORK WHEREVER ARE DAMPERS OCCUR. 7. DUCT SIZES WITH UNING SHOWN ARE NET, CLEAR INSIDE DIMENSIONS. 8. PROVIDE HVAC DUCT INSULATION IN ACCORDANCE WiTH SECTION 604 OF THE UNIFORM MECHANICAL CODE 1998. 9. ALL SQUARE ELBOW TURNS IN DUCTWORK SHALL HAVE TURNING VANES. 10. FURNISH AND INSTALL NOISE AND VIBRATION ISOLATION DEVICES ON DUCTWORK AND EQUIPMENT. 11. FLEXIBLE DUCT WORK SHALL NOT BE MORE THAN 6 FEET IN LENGTH FOR ANY ONE APPLICATION. 12. THE EXISTING CONDITIONS SHOWN ON THESE DRAWINGS ARE DEVELOPED FROM FIELD VERIFICATION. THE ENGINEER, HOWEVER, DOES NOT TAKE RESPONSIBILITY FOR THE COMPLETE ACCURACY OF THE PLANS. THE CONTRACTOR, THEREFORE, SHALL MAKE ALLOWANCES IN HIS BID TO PROVIDE A COMPLETE AND OPERABLE SYSTEM WITH THE INTENT AS DESCRIBED BY THESE DRAWINGS AND SPECIFICATIONS - MAKING PROVISIONS FOR FIELD ADJUSTMENTS AS REQUIRED. THE CONTRACTOR SHALL VISiT THE SITE PRIOR TO START OF WORK OR PRICING. CONTRACTOR SHALL PAY SPECIAL ATTENTION IN SCHEDUUNG CONSTRUCTION TO MINIMIZE DISTURBANCE TO BUILDING OPERATIONS AND "DOWN -TIME" OF HVAC SERVICE. CONTRACTOR SHALL PHASE CONSTRUCTION AND SCHEDULE DEMOLITION AND DISCONNECTION OF VITAL SERVICES AND SHUTDOWN OF EQUIPMENT TO COMPLY WITH OWNER'S INSTRUCTIONS AND REQUIREMENTS. PRIOR TO START OF WORK, CONTRACTOR SHALL COORDINATE WITH OWNER TO IDENTIFY AND PRESENT A CONSTRUCTION SCHEDULE WiTH ANTICIPATED "DOWN- -TIME" ON SERVICES. 13. 0. Combination Smoke Fre Dampers shall be installed where ductwork penetrates fire rated walls surrounding an exit corridor. E Combination Smoke Fre dampers shall be Ruskin, Submit cutsheets as required by Landlord for d equipment 2.05 INSULATION (Instded per Manufacturer's Recommendations) A. Heating and Coding Ductwork located in interior locations: Insulate with Owens- Coming • Fiberglas all service Duct Wrap Type 150 with factory applied flame retardant Foi Reinforced Kroft Facing (FRK -25 U.L labeled), or approved equal. Installed thermal resistance shah be a minimum of 4.2. 8. Acoustical Ductwork and Plenum and Casing Liner 1. Provide internally lined ductwork where indicated on drawings. Acoustical duct Iher shall be trdite duct liner, or e u , matte fate, 3 lb. density, 1 thidc. suitable for velocities from 1500 4000 fpm, in compliance w/ U1723 and U1181. Secure liner to ductwork with adhesive and mechanical fansteners per SMACNA Duct Liner application standard. 2. Where internal insulation is applied, duct and plenum sizes as shown on the drawings shdl albe inside dear dimensions. be applied 3. app 6v�ed o p mast ic s and �an ffostiaingg or' �e ce tin marlufocturer s 2.06 TEMPERATURE CONTROL SYSTEM Al Contractor shall furnish oil necessary control devices (relays, contacts, etc.) and shah obtain direction from manufacturer on octud wiring requirements. B. Contractor shall post in the office typewritten instructions on operation of al controls. 2.07 SEISMIC RESTRAINTS AND BRACING A. All HVAC equipment, ductwork, piping and wiring conduits shd be installed to meet the laterd bracing requirements for the applicable seismic zone. Provide seismic restraints in accordance with Seismic Hazard Levd (SHL) A of the 'Seismic Restraint Manual: Guidelines for Mechanical Systems' doted 1991, as published by S.M.A.C,N.A, and also in accordance with applicable local bulldog codes. B. Al rooftop equipment shall hove proper anchoring and restraint systems, and shall be secured to a roof curb, equipment pod or other structural member to prevent lateral, vertical or overturning movement without sacrificing any resiient vibration isolation requirements. 3.00 INSTALLATION AND EXECUTION 3.01 INSTALLATION REQUIREMENTS A. Ductwork I. Duct branches shall be fitted with volume or splitter damper and where required, extraction damper. All accessible volume controls shah hove socking quodrants. AN Inaccessible controls (dampers, etc.) shall be provided with permanent extensions to accessible spaces. Brandy volume controls are in addition to volume controls of registers and diffusers. 2. Air inlets, outlets shall be properly set in place„ Registers and grin shall be tightly sealed. NOTES INSTALL ALL DUCTWORK AND PIPING TO BEST SUIT FIELD CONDITIONS AND COORDINATE WITH THE INSTALLATION WORK OF OTHER TRADES. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE THE EXACT LOCATION OF SINGLE LINE DUCTS. THIS CONTRACTOR SHALL REFER TO ELECTRICAL CONTRACT DOCUMENTS TO OBTAIN THE INFORMATION OF STARTERS, VOLTAGE, PHASE, INTERLOCKING CONTROLS & MISCELLANEOUS EQUIPMENT SUCH AS RELAYS IN STARTERS, ETC.. SO THAT ALL ELECTRICAL EQUIPMENT SHALL FULLY COMPLY WITH ELECTRICAL AND CONTROL REQUIREMENTS. THIS CONTRACTOR WILL PROVIDE THREE COPIES OF OPERATING MAINTENANCE INSTRUCTIONS AND TESTING /BALANCE REPORT TO THE OWNER (IN VINYL COVER). ... -.-� E FOR REVIEW COOS APPRO Ut3 - 62004 A Dtal.•1 DRAWING SCHEDULE M1.0 MECHANICAL IEGEND, SPECS AND SCHEDULES M2.0 MECHANICAL HVAC PLAN M3.0 MECHANICAL HVAC DEfNLS FP1.0 FIRE PROTECTION PLAN & SPECIFICATIONS 3. Transitions in size of ducts shall be mode by uniformly tapering sections having 1 inch increase in width for each 7 inches of run unless construction limitations require o more 'abrupt transition. 4. Diffusers, Guiles and Registers: Each register and diffuser shall be equipped with a volume damper or air extractor. Paint interior surface of all units flat block. Face and trim of all units shall be finished Size, finish, frames, accessories, capacity and pattern as shorn on drawings. 5. Contractor shall provide manud volume dumpers at dl branch ductwork in y oir, return air and outside air systems (whether shown on plans or not where required for air balancing of HVAC systems. END OF SECTION SECTION 15990 - TESTING. ADJUSTING AND BALANCING 1.00 -GENERAL 1.01 DESCRIPTION The testing and balancing work mill be performed under o separate contract from the HVAC work The work described in this section shall be performed by on independent test and balance agency, specializig in testing organization. and babalancing of HVAC systems and a number of the AABC or approved equal 1.02 SCOPE OF WM A. HVAC . System Test and Balance in accordance with procedures established by MK or B. Measurement of find operating conditions of HVAC equipment C. Test and Balance Reports, (4) copies. 0. Each piece of air conditioning and heating equipment and the air distributions systems shd be tested and od jested to insure proper functioning of dl control, proper distribution of air, maintenance of temperature, diminotion of drafts, noise and vibration, and left in first class operating condition. The air system shat be read jested if required for comfort of each room. E. The mechanical contractor wil make any changes in the puNeys, belts, dampers, vines, baffles and the lice required for correct balance of system as recommended bt Tie agency and to the satisfaction of the owner. 1.03 SUBMITTALS k The test and balance report shall include, as a minimum, but not be limited to: 1. Each equipment shall be identified by equipment service number, manufacturer, model number, and serial number, motor horsepower, motor nameplate voltage, motor RPM, actual and design static pressure, actual outlet velocity, actual CFM, design CFM. 2. Each coil shop be identified by equipment service number, manufacturer, model number and size, number of rows, totd CFM, air inlet and outlet dry bulb and wet bulb temperatures. 3. Each air outlet shall be identified with manufacture, model number, size, velocity, correction factor, actual CF'M, design Chun. 4. Traverse Treading of main supply, return and outside air ducts to establish air quantities. 5. Test and record temperatures from temperature controllers such os day thermostat night thermostat 6. Test and record temperatures from main supply air trunk, mixed air during the full heating and full cooling cycle and economizer cycle. 7. Tat and balance economizer. ENO OF SECTION 'a *ot xxx ENERGY • CONSERVATION • COMPANY No. Dote Issue v'f . f•t•e trill ti o• ENCON 4940 El Camino Real Loll Altos, California, 94022 tel / (650) 961 -8095 fox / (650) 964 -3754 email i foOencon.com Copyright • ENCON 2004 ENCON Project /: AP4805.00 5/26/04 ISSUE FOR PERMIT _ 40060 NTS PIPD • U z LU at 0 U W Store No. R -106 South Center Mall Seattle, Washington tit .. its I :tf,,; ±ii11J>f!: •jf�l��f :11 teteliislel 15;1 0 set F IV' I t liliircltl. •1e4 @r C If:146 c4istnt of the lrtli :e;' C )R- � ;CEO 9 MECHANICAL LEGENDS, SPECS & SCHEDULES M1.0 HP -1 ON ROOF. LOCA SHOWN IS SCHEMATIC (14'x10'1 -1 500 (ECONOMIZER REUEF HOOD) 161 12'0 r S G- -(14'x 101 500 CO -1 ! ( • t., Yt 8' 0 , CR -1 16"4 p • P 200 .�= ( r Rc -N 3 6`x 167 1190' CO -1 / 100 I t , . __ 8 . O ' ,: 7 O cR -1 6'0-1 150 (370 LBS :' ()REFRIGERANT PIPING TO -- - -_.... 1 ■ ON ROOF - _ I•= _a- -..... ti . .. ' 1 ::.. LD— A (TYP. 8) 200 (TYP. 8) .. t : --- =- = _! _- •_:- ri m- _. 7 __1.- _ .. .: - 7:7-1 '.7 - _ -.. o f ,LD -A .t 12`x20` R/A re- SCALE: 114" = 1'-0' • • mo w. 10'0 TAP FROM BOTTOM OF 12`x20' DUCT TO 48`x81H) PLENUM (TYP. 8) HVAC - FLOOR PLAN 2 —12"x16` R/A —10`0 TAP FROM BOTTOM OF 12"x20` DUCT TO 48'x8'(H) PLENUM (TYP. 8) • +`.S� �-..�. �..__.... _ �...'"� Y om - ... •. .. TAP 12'O TO TOP OF 12`40` DUCT SHEET NOTE: —12%14* R/A t . 12`x10` R/A RG -1 (TYP. 8 - 6`x6'' 50 (SERVES INTERSTITIAL SPACE) - _ • - • _ = 48'x81H) RA PLENUM - , ACCOUSTICAL LINING (TYP. 8) • 48x (H) SA PLENUM - w ACCOUSTICAL LINING (TYP. 8) w. SG -1 (TYP. 8 - 6`x6') 50 . (SERVES INTERSTMAL SPACE) 0 DUCT MOUNTED SMOKE DETECTOR WIRED TO SHUT DOWN THE HVAC UNIT UPON SENSING SMOKE. SMOKE DETECTOR MUST BE INSTALLED IN AN ACCESSIBLE LOCATION. REFRIGERANT PIPING TO NEW HP -1 ON ROOF. REFRIGERANT PIPING TO BE SIZED PER ACTUAL LINE LENGTHS. CONTRACTOR TO MAKE A SKETCH OF PIPING ROUTING FROM FC -1 TO HP -1 (INCLUDE DISTANCES AND RISER HEIGHTS). PROVIDE SKETCH TO ENGINEER FOR ANAL SIZING. (NOTE: UNE LENGTH SHALL NOT EXCEED 80' -0`) NEW EF -1 IS TO BE LOCATED ON ROOF. COORDINATE LOCATION OF EF -1 WITH MALL'S CHIEF ENGINEER, RON HOPKINS 0 (206) 246 -0423. FIELD VERIFY EXHAUST IS MINIMUM 10' -0' FROM OUTSIDE AIR INTAKES. 1 r • NEW HP -1 IS TO BE LOCATED ON ROOF. COORDINATE LOCATION OF HP -1 AND PIPE ROUTING WITH MALL'S CHIEF ENGINEER, RON HOPKINS 0 (206) 246 -0423. CONNECT NEW 36`x24' OSA DUCT UP TO NEW OUTSIDE AIR INTAKE ON ROOF. CONTRACTOR TO VERIFY OSA DUCT IS A MINIMUM 12' -0' FROM ANY EXHAUST. `GREENHECK' OUTSIDE AIR INTAKE 'FABRA HOOD', 36'x24' THROAT, 191H), CONNECT TO FC -1 (3,300 CFM, 0.05"W.G. PRESSURE DROP, 550 FPM 0 THROAT), PROVIDE MFR. ROOF CURB. COORDINATE EXACT LOCATION WITH LL CHIEF ENGINEER, RON HOPKINS (PHONE: (206) 246 -0423) r_ :Tr..: MOTORIZED DAMPER FOR ECONOMIZER - 'TYPICAL FOR OSA AND RETURN DAMPERS 'GREENHECK` REUEF AIR 'FABRA HOOD`, 36`x24' THROAT, 19'(H), PROVIDE COUNTERBALANCED BACKDRAFT DAMPER FOR ECONOMIZER REUEF, MFR. ROOF CURB. CONTRACTOR TO INSTALL A MINIMUM OF 12' -0' FROM ANY OUTSIDE AIR INTAKES. COORDINATE EXACT LOCATION WITH U. CHIEF ENGINEER, RON HOPKINS (PHONE: (206) 246 -0423) • • 1 .... :.::....-._:_..-....v t • 2 GENERAL NOTES: 1. EXISTING SPLIT SYSTEM AND ASSOCIATED DUCTWORK TO BE DEMO'D AND REMOVED. REVIEWED FOR CODE COMPLIANCE APPROVED AUG - 6 2004 City Of Tukwila DIVISION t ENCON ENERGY • CONSERVATION • COMPANY 4940 U Comino Real Los Altos, California, 94022 tel # (650) 961 -8095 fox • (650) 964 -3754 ernoil infolencon.com Copyrroht • ENCON 2004 ENCON Pr • • -• t ,#: AP4805.00 P I t T►�Ir f I � •- � r• rte• � I EXPIRES I I/6 :�- , 4.4._ Store No. R -106 South Center Mall Seattle, Washington c$ "pOitc!!; tug '•;.1 It:! s••; ;/ :. ►� EI f:!► i$P3 1. !'►'4 { • i (ti:t• ? •,f ;ills ' ne J . No. Dote Issue 5/26/04 ISSUE FOR PERMIT 1 A EAst., t • U z ce LU O 0 V LU a i 't 26 ..- •' 2 2 2001 EMIL 41612 Mir 1/4" = 1' 0" MECHANICAL HVAC PLAN M2.O COIL TYPE H1 (HEIGHT) H2 (HEIGHT) BLOW— THROUGH (LOCATED ON DISCHARGE SIDE OF FAN) 1" MINIMUM POSITIVE STATIC PRESSURE AT DRAIN PAN IN INCHES TIMES 2 (2" MINIMUM) DRAW— THROUGH (LOCATED ON SUCTION SIDE OF FAN) NEGATIVE STATIC PRESSURE AT DRAIN PAN IN INCHES PLUS 1 INCH NEGATIVE STATIC PRESSURE AT DRAIN PAN IN INCHES PLUS 1 INCH FIAT OVAL EQUIVALENT ROUND ROUND • FLAT OVAL INCHES 6" 4X9 7` 5X10 8' 6X11 10" 6X11 12" 7X20 14' 8X22 INSUUTION 8'x48' PLENUM BOX WI 1/2" ACOUSTIC LINING SUPPLY AIR PLENUM DETAIL 12 "x20' SUPPLY AIR DUCT STAINLESS STEEL PERFORATED PANEL NOSING — CLIP ALL AROUND do SEAL NOT TO SCALE ROLL WYE TOWARD SLOT INLET NECK MAIN DUCT DIELECTRIC FITTING (FOR COPPER PIPE APPUCA11ON) COOUNG COIL DRAIN PAN CLEAN OUT PLUG, BOTH ENDS BALANCING DAMPER ROUND TAP TO ROUND MAIN ROUND TAP TQ RECTANGULAR MAIN • (TAP SMALLER THAN MAIN) BRANCH CONNECTIONS TO MAIN - LOW PRESSURE H1 H2 z r--Y LATERAL FITTING COOLING COIL CONDENSATE TRAP 45 . SPIN —IN ROUND COLLAR WITH 3/8" RAISED BEAD & BALANCING DAMPER MAIN ROUND DUCT (/))//-- FLEXIBLE DUCT TO DIFFUSER ROUND DUCT COLLAR WITH 3/8" RAISED BEAD AND BALANCING DAMPER FLEXIBLE DUCT TO DIFFUSER OPEN END WITH VENT CAP ALL PIPE SIZED PER U.M.C. (1.8' MINIMUM) SL OPE DOWN N2" PER FOOT TURN DOWN OVER DRAIN, PROVIDE 1" AIR GAP OR UNION CONNECTIONS TO CONDENSATE PUMP I NOT TOSCALE MAIN SUPPLY DUCT 12x20 SA w/1 "AL 100 8 "x48" PLENUM BOX w/1/2" ACOUSTIC UNIOG BALANCING DAMPER ROUND TAP TO RECTANGULAR MAIN (TAP LARGER THAN MAIN) OVAL TO ROUND TRANSITION REVIEWED FOR CADE COMPLIANCE APPROVED ALIO - 6 2004 ,y Of Tukwila BUILDING DIVISION (50) 01-1■ (200) FIAT OVAL, SEE SCHEDULE FOR EQUIVALENT TO ROUND SIZE frIDL SUPPLY DUCT CROSS SECTION ROUND CONNECTION WITH 3/8' RAISED BEAD SAME DIAMETER AS FLEX CONNECTION. FLEXIBLE DUCT TO DIFFUSER NOT TO SCALE 12x20 RA W/1 AL 8 "x48" PLENUM BOX I NOT 10 SCALE ENERGY • CONSERVATION • COMPANY • • a • . ENCON 4940 El Camino Reol Los Altos, Coliforna, 94022 tel i (650) 961 -8095 fox (650) 964 -3754 emoil info0encon.com Copyright • ENCON 2004 ENCON Project #: AP4805.00 JUL 2 2 2004 L AP$RE; i , , ' No. Out Issue 5/26/04 ISSUE FOR PERMIT 40060 • U Z 0 0 V W a a Store No. R -106 South Center Mall Seattle, Washington .1•i'7 "fM• J,jSIi'••'l!• ••.•f R i) Ver' i:Sktt i$ia r ' �: f:ih l!. iMj r - 0 0'1 'I .y� irsit'1 (- Ii n r, , r r r NTS ERIE MECHANICAL HVAC DETAILS M3.O DATE: