Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M04-177 - 7-ELEVEN
1 14207 TUKWILA INTERNATIONAL BL Parcel No.: Address: Suite No: Tenant: Name: Address: City o1 Tukwila 1610000295 14207 TUKWILA INTERNATIONAL BL TUKW 7- ELEVEN 14207 TUKWILA INTERNATIONAL BL, TUKWILA WA Owner: Name: HIRSCHBURG PETER L Address: C/O THE SOUTHLAND CORP, PO BOX 711 Contact Person: Name: PETER CRELLEY Address: P.O. BOX 33370, SEATTLE, WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Contractor: Name: PRO STAFF MECHANICAL INC Address: PO BOX 33370, SEATTLE WA Contractor License No: PROSTMI072NG MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: REPLACING ONE EXISTING ROOF TOP REFRIGERATION UNIT AND ASSOCIATED INDOOR EQUIPMENT PLUS REFRIGERATION PIPING. "LIKE FOR LIKE" REPLACEMENT. Value of Mechanical: $9,500.00 Type of Fire Protection: N/A Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 1 Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC- Permit EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M04 -177 Phone: Phone: 206 361 -0071 Phone: 206 - 361 -0071 Expiration Date:06 /30/2006 Steven M Mullet, Mayor Steve Lancaster, Director M04 -177 10/14/2004 04/12/2005 Fees Collected: $269.58 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 10 -14 -2004 Permit Center Authorized Signature: doc: IMC-Permit Signature: City o;; Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Print Name: l"����lZ 6)261 - e y Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M04 -177 Issue Date: 10/14/2004 Permit Expires On: 04/12/2005 ee Z,Obt ( Date: /o / / t V / L / I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construt(on the perform pce of work. I am authorized to sign and obtain this mechanical permit. M04 -177 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 10 -14 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1610000295 Permit Number: M04 -177 Address: 14207 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 10/05/2004 Tenant: 7 - ELEVEN Issue Date: 10/14/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M04 -177 Printed: 10 -14 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. doc: Conditions M04 -177 Date: of law and ordinances other work or local laws Printed: 10 -14 -2004 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** REF Pr s2r•r MD3— -t � �- :.��•.;S�F;:i.�,. , ;�i .. �' , _:'t•;:.huti' '.ii�'t;.t v. �,:.y r:�, :,•,.:rt.,' � +s? U �i :�n�:;��:e�::5;.i•��7ii ,'�rt:� ^.='t ;'SA.:. } ':i ».,:;�; ,r at` �ri4:a:. . _ .t br^41 s'wF:r �1�' � •�}f,�. rVt .,f r .`'tr"'::= c.'z?c: '�;,;d�= ,'-�?J,''L"- ;r:. �,�,'•!':iyi"w .2:��b R' ,;tiC.- .:•hl:.':'.'�.'S4� ;:i::.* �' i:::.�'r: {:f?..i�,.:; � ..= ::,�.�' wt� . SITE' OCA'I3N , s�� -` w1 C r � aL,r ;: H .t .., i M,: 4 ,�' I' :� t > i, . }' s, A .�i� :.:•:`_.• � Ali �T!i.'L'«.i s.,Sx'NFit%:I ^S' lic tas :W, , i. 1'4� ..: x'r �: �7.il•x•.tx '�•r H ?;V ` . 4. Site Address: Tenant Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 j UK 1I A 7.trtrRN,J lo,.4L st -,VD, King Co Assessor's Tax No.: 142- v 7 ('Ac.1 i i t. H w'/ 55..) 9'3)&6 Suite Number: Floor: - iELt= N Property Owners Name: 7- et.el/6 /4 ( µttzsemar_u:c, . tOv'1 L4ie1> Cotrr1 Mailing Address: 2-o ' 11 7241 A1/6 S., $Oc-) Name: fe i G iz CR r_LLr y Mailing Address: P. 0.. 333.70 E -Mail Address: pet erQ pro- if off ni e a n i ` t 1 . Co el pit INFORMATIO Company Mailing Address: / City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration D'ate: * *An original or notarized copy of current Wad. ^ gton State Contractor License must be presented at the time of permit issuance ** ARCHITECT•OF 'REC Company Name: Mailing Address: Contact Person: 'ENGINEEWO Company Name: Mailing Addres( Vppticationatpennit application (3.2003) 3/2003 keror City :ems -r r Al l.plans'must°lie;wet`stampe Con Person: E -Mail Address: et'sfamped� by?��it•chifect:ofRecord,: Page 1 4 • iyr Day Telephone: • - Olo — G) 0x t Da T lephone: Numb 1 (#1 O 7 0 07 — q New Tenant: D .... Yes 2 .No State State Tsiin 9 3032 Zip ��ATTL'c 14',4 City State Zip 2 Fax Number: O — 3 bl — 01 124 Zip E -Mail Address: Fax F: rs•` . City State Zip, Day Telephone: Fax Number: 04, 'vwML ..iN41�. hli�t �..:24i.,.+•Li.it"w.ir:.r� [ + {„ +:: 4 'YntL^•4i�W:} , »i+.•�%+ :%''.N ..4 vi;.,dS,.4 • .. ...., L: ' ,� Extstuig •, ie ? `= . �j �,' Interior ,,. Remodel -:= Addition to. Extsitng Structure ; , New � T structt Con n st r .. per T e f •. , 4 O ccup y per' arc UBG ;l 'Floor .,. .. :.2"°;Floor:,.- . :.::. ..:: :: _ . -`3'* Floor." : Floors thrti:' , ' Basement Accessory: Stricture! ' Attached, Garage Detached,:Garage::' .i .,7tiy Attached;C -: =;t;° • . Detached art" Covered'Dec vx ' Uncovered:Deck; U ILDING PERNII T:-INFORMATION•;4 06-43.1 =3 tapplication\pcnnit application (3.2003) 3/2003 Page 2 Will there be new rack storage? ❑ ..Yes ❑ .. No If "yes ", see Handout No. for requirements. Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): rovide:A11 Building Areas in'Sdogre:Foota e Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑ ..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes ❑..No If 'yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. PUBLIC WORKS PER114IT INFO - :TIOI�T `' "206- 433.0179 ,;'r "!.� • w 4 y; " '''�� u ?r Tt. xt '� �.} • n � `s t � I�".�� ? y ys •�s r., i w'?:�- -5 . � �` .. , .r�.. ° tA`'�1 . .. ti , s _,e:`tv ., ,'i "'�'tf� "•" .'.; %:;r Scope of Work (please provide detailed information): Water District ❑ ...Tukwila 0... Water District #I25 ❑ ...Water Availability Provided Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size —.22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance . ❑ ...Construction /Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards j ❑ ...Total Fill cubic yards •s ❑ ..:Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ ...Cap or Remove Utilities ❑ .. Curb Cut '0 ...Frontage Improvements ❑ .. Pavement Cut 7 ...Traffic Control ❑ .. Looped Fire Line 1...Backflow Prevention - Fire Protection ;Permanent Water Meter Size... :Temporary Water Meter Size.. Water Only Meter Size :. :3ewer Main Extension Public _ ,J ...W.'ater Main Extension Public FINANCE INFORMATION applicationt'pamit application (3 -2003) 3/2003 „ eiisOeferto;Pitblia tWorks'$ulle,tirt #1 fo"r, 1 and`estiittate'sheet Irrigation Domestic Water Call before you Dig: 1 800 - 424 - 5555 WO# WO# WO# Private Private Page 3 ❑ .. Highline Sewer District ❑ ...Tukwila ❑ ... ValVue ❑ .. Renton ❑ ...Seattle ❑...Sewer Use Certificate ❑...Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) • ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Deduct Water Meter Size Fire Lino- Size at Property Line Number of Public Fire Hydrant(s) ...Water ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Mailing :Address: Day Telephone: City Water Meter Refund/Billing: Name: Mailing Address: State Zip Day Telephone: City ❑ ...Renton ❑ ...Traffic Impact Analysis ❑...Hold Harmless ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding State Zip Unit Type: :;... YP Qty,' . . .nit -TYPeS . h':;' :Unit-Type:' e:�.�, . YP .: Qty ,::, Bo41er /Compressor: - .:.: ty ... Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>I00K BTU Evaporator Cooler 3 -15 HP /500,000 BTU 1 Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind "•MECIIMiIC2SL �PERIIT IN FORMATION "- 206431 =36 ., >' %��'.. :.a gip: i•;n }. � :t. , itz; .4ti; „ . _ it 49J, ; » �.,•=,L :a a ,i�.��Z;.s•2 '•o : i, MECHANICAL CONTRACTOR INFORMATION Company Name: 1Zo — ) 4 Mailing Address: f'_ Contact Person: Pi: 1Z CRS L LO. - y L. City W,4 Day Telephone: � b /— vZ:='71 E -Mail Address: Pr7.4e. 1 - Pao— GAFF Vh; 4N 1`i4L ..c 'Y Fax Number: 217 Q E 1= AT, nN gePiz) z,r 1t ATIc3N Indicate type of mechanical work being installed and the quantity below: PERMIT: APPIICATION: NOTES :<Appli'cableto`a11::j Date Application Accepted: \appiicatiautpatmil application (3.2003) I Date Application Expires: ? ■S - D 5 permits: in th>ts appLcaQoq State `re /33 Zip Contractor Registration Number: osei M 1..07 N c, Expiration Date: G� /v * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ ( 3,5 -0 0 Scope of Work (please provide detailed information): R e Pt.A -cat. t9 N r a x/.' i IN c-, UN )7 AND / 0GI/1`11`1:› 11.4 PO c E MA? PIChM' PC-td L-1 - 1~ D2- L- k C ti l2. EPt,4. GS rwnSAYr Use: Residential: New .... Replacement .... Commercial: New ....0 Replacement .....6 Fuel Type: Electric re Gas ....p Other: Day Telephone: 2 DG — 3GI 0 17"7/ Date: 12 fa 9- Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDEF.l PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERIvlIT. BUILDING OWNE pUTHORI AGENT: Signature: Print Name: 76 IL CR E Mailing Address: ? U_ $v c 33370 36A T TLt 141/1- DI J17S3 City State Zip Staff Initials: 4 Parcel No.: 1610000295 Permit Number: M04 -177 Address: 14207 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 10/05/2004 Applicant: 7- ELEVEN Issue Date: Receipt No.: R04 -01363 Initials: SKS User ID: 1165 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payee: PRO -STAFF MECHANICAL TRANSACTION LIST: Type Method Description Amount doc: Receipt Payment Check 8359 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES :PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000/322.100 221.66 000/345.830 47.92 Payment Amount: 269.58 Payment Date: 10/05/2004 04:01 PM Balance: $0.00 269.58 Total: 269.58 WO .10/05 9716 TOTAL. 269.58 Printed: 10 -05 -2004 co w: N w; • ul J N D • W. Z :. Z W W • U ;O N W W'. O Z Iii U N ' 2 Project: 7 / Type of Inspe, ctgn: cr )1�,,Q Address: ' `1 Date Calle Spe l In tr cti ns: Date Wanted: siAZINEW ,3 . m Requester: Phone No: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 20 • )4 1 -3670 Corrections required prior to approval. COMMENTS: j v °° F $47.00 REINSPECTION FEE RE (RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: ��/ T p f In;s,ction: �41.. /("7 r� SS �,r�'�!Y Address: a.4 /te a e Special Instructions: / 6 roo Date Waited: / 7 a:m Requester: Phone No. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PER NO. 1 -3670 COMMENTS: 'Date: Approved per applicable codes. Corrections required prior to approval. D $5 .00 REINSPECT! FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: �U U O, CO 0 CO w! Ca W Or rnd :. Z W �J U 0 i0 N , o ;ui w U. — O Z t1J U co O Pro 7 - )Q \e1� Type of Ins Er ion: 1i A r -�-�.� D ate Called: X015' Specs I Instructions: Date Wante : �„� / f m. __V — il(C5 p.m. Requester: 73; _ [ -- no7( INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 C MMENTS: J Pk-,:.4 Lif 4/L ( a--LL I Date il Approved per applicable codes. Corrections required prior to approval. El $58.00 REINSPECTION tE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: A� AL 1/2, 3/4 and 1 HP Dimensional Drawings OUTDOOR LEFT VIEW I--• -- ae -//4 ----I 1 -1/2 and 2 HP I - -- 26 -/ /4 - ----•1 3 HP — ALTERNATE CABINET 3,4,5 and 6HP I. 30-1/4 2- I/16 23-1,4 a 7/16 X 11/16 SLOT liP 4 It 17 -1/4 r 16 -3/4 FRONT VIEW 42-I,? 37-3/4 37 -3/4 23 -3/4 23 4 4 -1.16 1 -16/16 3 -11/16 f -7/e l 4f I - /5//6 I 3 - 11/16 C O F TUK i OCT 5 2004 PERMIT CENTER 3/4 3 - 1 T 2 -1/4 2 -1/4 A B C 6-1/4 4 - 15/16 3 -13/76 3 -1/4 D 5 -1 /4 4 -15/lu 3 -13/16 INDOOR FRONT VIEW DVS (21 7.47 s 1-3/4 36 - I/4 a. 34-1 7/16 X Il /16 3O7 TYP4ACS ___2 a. (2) 7Ie, (1I l [11 1 -3/4 43 C. IS - u PRO- STAFF' MECHANICAL INC. P.O. BOX 333'i U SEATTLE, WA 9813: 1216'36 - ^ O71 Oql 77 1 � p 'exf 1 s,�?a7 � , 0 , I oriel BH* -005112 s ; .r. •S �F � > i r epressor, ART82C1 �� ki E, ..: � �f 1 40°F ` 8050 , < < r" C ;30 ° F 6610 ,,Capacity BTUMR @ 98,.F.' ,. ��r Suctio Temperature �t� .r ��., t :r �,v '• • 2 20 ° F, 15 °F 5960 5360 4820 '' t 10° 4350 t 3630 • BH *-008112 RS64C2 11550 9390 8350 7350 6420 5470 4050 BH* -010112 RS70C1 12990 10650 9500 8380 7320 6250 4370 BH* -015112 CR18KQ - 14520 12910 11340 9860 8380 5640 BH * -020H2 CR24KQ 23190 18980 16910 14900 12990 11090 8150 BH* -029M2 CR37KQ - 26750 23930 21160 18480 15920 11310 BH * -030H2 CR37KQ 38230 31710 28090 24610 21260 18140 12580 BH *• -040H2 CR53KQ 54690 43950 38840 33930 29270 24920 17240 BH* -050112 CRN -0500 61680 49760 44050 38560 33340 28440 19750 R -22 Capacity BTIJ/HR @ 90 'Amt icjit Suction Temperature P Model Com•ressor .,40 °F. . . 30 °F . .25 °F' , 2p ° F., ..15 ° F;. ,.,19 0 • , -... B11* -005112 ART82C1 8380 6900 6230 5610 5060 4570 3830 B11* -008112 RS64C2 - 9860 8770 7720 6730 5740 4250 B11* -010H2 RS70C1 13640 11180 9980 8800 7690 6560 4590 BH* -015112 CR18K • - 15250 13550 11910 10350 8800 5930 BH* -020112 CR24K • 24360 19930 17760 15650 13650 11640 8560 BH * -029M2 CR37K • - 28090 25120 22220 19410 16720 11880 BI1* -030112 CR37K• 41190 33300 29500 25830 22330 19040 13210 BH* ..040H2 CR53K • 57430 46140 40790 35620 30740 26150 18100 BH* -050112 CRN -0500 64770 52240 46250 40490 35010 29860 20740 R -22 , Capacity, 13T1J%HR @ >'I00 °F Ambient Suction Temperature °F: `'" • Model Compressor .. 40°F. 30°F. ,. . 25 ° F „` ' 20 °E.' 15 .1 0 .... .'n°F.:, BH * -005H2 ART82C1 7710 6320 5690 5110 4590 4130 3440 BH * -008H2 RS64C2 10970 8930 7940 6990 6100 5190 3850 BH * -010H2 RS70C1 12340 10120 9030 7960 6950 5940 4150 BH * -015H2 CR18K• - 13800 12260 10770 9370 7960 5360 BH * -020H2 CR24K • 22030 18030 16070 14160 12340 10540 7740 BH* -029M2 CR37K • - 25410 22730 20100 17550 15130 10740 BH* -030112 CR37K • 37270 30130 26690 23380 20200 17220 11950 BH* -040112 CR53K • 51960 41760 36890 32240 27820 23670 16390 BH* -050112 CRN -0500 58600 47270 41850 36630 31680 27020 18760 R -22 C aOaCity s EITLAIR . ThltibE Suction Temperature °F. Model Compressor 40 ° F. 30 °F '. 25 °F. 20 °F. 15°F 10°F.' _:0°F;:' BH * -005H2 ART82C1 7040 5740 5150 4600 4110 • 3690 3050 BH* -008112 RS64C2 9570 7680 6790 5970 5180 4480 3320 BH* -010112 RS70C1 10600 8540 7530 6560 5630 4760 3200 BH* -015112 CR18K• - 12360 10980 9610 8320 7090 4860 BH * -020H2 CR24K • 19770 16180 14410 12680 11000 9400 6490 BH* -029M2 CR37K • - 22690 20190 17760 15420 13200 9290 BH* -030112 CR37K• 33900 27120 23870 20760 17820 15080 10350 B11* -040H2 CR53K• 48390 38470 33780 29320 . 25120 21230 14550 BH* -050112 CRN -0500 54770 43730 38490 33470 28740 24340 16760 Performance Data - Medium & High Temp. Models - Hermetic Compressors = Tfor Outdoor, N for Indoor, B for Bohnmizer, S for Beacon IIT" 7 BH *005X6 A RS43C2E 3/8 1/2 5.5 1 28.25 23.75 17.25 135 68 BH *008X6 A RS55C2E 3/8 1/2 5.5 1 28.25 23.75 17.25 135 68 BH *009X6 A RS64C2E 3/8 5/8 5.5 1 28.25 23.75 17.25 144 68 BH *010X6 A RS70C1E 3/8 5/8 5.5 1 28.25 23.75 17.25 138 68 BH *015X6 B CS10K6E 3/8 5/8 9 2 28.25 37.75 17.25 193 71 BH *020X6 B CS12K6E 3/8 7/8 9 2 28.25 37.75 17.25 203 73 BH *025X6 B CSI4K6E 3/8 7/8 9 2 28.25 37.75 17.25 208 74 BH *030X6 D CS18K6E 1/2 7/8 20 1 30.25 42.5 29.75 290 73 BH *032X6 D CS20K6E 1/2 7/8 20 1 30.25 42.5 29.75 275 76 BH *040X6 D CS27K6E 1/2 1 -1/8 20 1 30.25 42.5 29.75 281 73 BH *050X6 D CS33K6E 1/2 1 -1/8 20 1 30.25 42.5 29.75 313 73 BH *011L6 A CF04K6E 3/8 5/8 5.5 1 28.25 23.75 17.25 139 73 BH *014L6 A CF06K6E 3/8 5/8 5.5 1 28.25 23.75 17.25 170 73 BH *025L6 B CF09K6E 3/8 7/8 9 2 28.25 37.75 17.25 222 76 BH *031L6 C CF12K6E 1/2 7/8 14 2 28.25 37.75 19.75 223 77 'ertormance Data - Low 1 em • erature Moaeis - Hermetic uom • ressors 8404/507 1 • Capacity BTUFi @ 90 °F..Arnbipnt J `auction Temperature °F. '• Model.. r . Compressoi • Q °F......,. 5°F ... _.' _ 0 _ ° _F.ti' - --1 ' r `, 3o °F&S BH *01126 CF04K6r ` 7484 6624 5765 4090 3293 2536 BH *0141.6 CF06K6E 10610 9460 8340 6220 5250 4340 BH *025L6 CF09K6E 17940 15970 14050 10400 8700 7130 BH *031L6 CF12K6E 20793 18889 16931 12938 10952 9009 RS64C2 3/8 84041507• = ; ; ;_= S: C apacity ;_BTUH` @:95 °F,.'Ambtent;:I Suction: Temperature , °F. '1, tx Models .'� :•Compressor , . ;: 0 °F ':t , . -5 °F .. , -1 -20°F : -25°F i , , -30° B11*011L6 CF04K6E 6930 6109 5289 3684 2919 2196 BH *014L6 CF06K6E 9980 8870 7790 5740 4810 3940 BH *025L6 CF09K6E 16870 14990 13150 9650 8040 6560 BH *031L6 CF12K6E 19598 17782 15909 12070 10152 8268 R404/507 Capacity f STUN @ 190°F. Ambient 7 Suction Temperature ° F.` Model ' _... Compressor,,... 0°F -5°F ._', 5.•., -., -1°F ,_;2P °F f':,..g.4,° 7,PP° -r; BH *011L6 CF04K6E 6379 5597 4814 3281 2549 1856 BH *014L6 CF06K6E 9360 8280 7230 5270 4370 3550 BH *025L6 CF09K6E 15810 14000 12240 8910 7390 6000 B I *031L6 C 12 6E 18410 16681 14892 11206 9354 7 30 404/50 110°F fl Cajty.TiJ i?: F _.. • . ,... -... D $tactio7r errtpe t r Mod - .w_ '.Cpn presso .:._..< . , -- $-- .`,..5 '.F..,,.,..:,... - 1 6 • . i_ .. - -2p4 ,_._ . 4F = ^s Ti m BH *011L6 CF04K6E 5288 4581 3872 2477 1809 n/a BH *014L6 CF06K6E 8130 7110 6130 4310 3500 2770 BH *025L6 CF09K6E 13680 12050 10440 7440 6080 4850 BH *031L6 CF12K6E 16056 14500 12875 9490 7770 6061 Model Number ' PI ' 2 Fig, ---t: A ' TIT Copneppions (1D1 Compr .Ltquld . Sugtiort. A' : 3/: 1 2 Receiver : , 0%:f..,1-ill ` 14 - ; s.,. 6 Fans) - 1 r - D la ' 28.2 r�4 f .- ' :I- 1r/�...�. BDit ,.' i l 'N.Y 1-1 .. , . !iv_ . Ala 2 .7 17.2 �:17"'�'aw� e- m ille ''Spytl f Wt o 18 . BH *008H2 A RS64C2 3/8 1/2 6 1 28.25 23.75 17.25 141 68 BH *010112 A RS70C1 3/8 5/8 6 1 28.25 23.75 17.25 136 68 BH *015112 B CR18KQ 3/8 5/8 10 2 28.25 37.75 17.25 189 71 BH *020112 B CR24KQ 3/8 7/8 10 2 28.25 37.75 17.25 193 72 BH *029M2 C CR37KQ 1/2 7/8 16 2 28.25 37.75 19.25 214 72 811*030112 D CR37KQ 1/2 7/8 22 1 30.25 42.5 29.75 281 73 B11*040112 D CR53KQ 1/2 1 -1/8 22 1 30.25 42.5 29.75 299 73 BH *0501-12 D CRN -0500 1/2 1 -1/8 22 1 30.25 42.5 29.75 ( 510) 75 Unit Specifications - Hermetic Compressors * =T for Outdoor, N for Indoor, B for Bohnmlzer, S for Beacon llTM ++ = See page 23 for details t = Estimated sound pressure values are 10 feet from the unit, For estimating sound pressure from the unit at different distances, deduct the following from the unit values: 20 feet, deduct 8 dba..... for 40 feet, deduct 12 dba for 80 feet, deduct 18 dba This data is typical of "free field" conditions for horizontal air cooled condensing units at the outlet of the discharge air The actual sound mea- surements may vary depending on the condensing unit installation. Factors such as reflecting walls, background noise and mounting conditions may have a significant influence on this data. 9 BH *005X6B RS43C2E -CAV 208 -230 1 60 4.8 24.1 1 1/15 0.5 15 20 15 20 8 15 BH *008X6B RS55C2E -CAV 208 -230 1 60 5.4 40 1 1/15 0.5 15 20 15 20 8 15 BH *009X6B RS64C2E -CAV 208 -230 1 60 6.9 37 1 1/15 0.5 15 20 15 20 7 15 BH *010X6B RS70C1E -PFV 208 -230 1 60 6.3 34.2 1 1/15 0.5 15 20 15 20 7 15 BH *010X6C RS70C1E -TFC 208 -230 3 60 4.2 31 1 1/15 0.5 15 20 15 20 8.6 15 BH *015X6B CS IOK6E -PFV 208 -230 1 60 9.8 56 2 1/15 1 15 24 20 25 6 19 BH *015X6C CSIOK6E -TF5 208 -230 3 60 6.7 51 2 1/15 1 15 20 15 20 7 15 BH *020X6B CS12K6E -PFV 208 -230 1 60 9.8 56 2 1/15 1 15 24 20 25 6 19 BH *020X6C CS12K6E -TF5 208 -230 3 60 6.7 51 2 1/15 1 15 24 15 25 9 19 BH *025X6B CS14K6E -PFV 208 -230 1 60 11.2 61 2 1/15 1 15 29 25 30 6 23 BH *025X6C CS14K6E -TF5 208 -230 3 60 8.2 55 2 1/15 1 15 24 15 25 9 19 BH *025X6D CS14K6E -TFD 460 3 60 4.2 28 2 1/15 1 15 20 15 20 A A BH *030X6B CS18K6E -PFV 208 -230 1 60 14.4 82.0 1 1/3 3.5 21 38 35 45 12 30 BH *030X6C CS18K6E -TF5 208 -230 3 60 9.4 65.5 1 1/3 3.5 15 29 20 30 7 23 BH *030X6D CSI8K6E -TFD 460 3 60 3.9 33.0 1 1/3 1.9 15 24 15 25 A A BH *032X6B CS20K6E-PFV 208 -230 1 60 16.7 96.0 1 1/3 3.5 24 38 40 50 12 30 BH *032X6C CS20K6E -TF5 208 -230 3 60 10.3 75.0 1 1/3 3.5 20 29 25 30 7 23 BH *032X6D CS20K6E TFD 460 3 60 4.6 40.0 1 1/3 1.9 15 24 15 25 A A BH *040X6B CS27K6E -PFV 208 -230 1 60 21.5 121 1 1/3 3.5 30.3 44 50 60 12 35 BH *040X6C CS27K6E -TF5 208 -230 3 60 13.7 105 1 1/3 3.5 20.7 38 30 45 12 30 BH *040X6D CS27K6E -TFD 460 3 60 7.6 52 1 1/3 1.9 15 29 15 30 11 23 BH *050X6B CS33K6E -PFV 208 -230 1 60 27.6 125.0 1 1/3 3.5 38.0 59 50 60 12 47 BH *050X6C CS33K6E -TF5 208 -230 3 60 16.8 102 1 1/3 3.5 24.5 38 40 50 12 30 BH *050X6D CS33K6E -TFD 460 3 60 8.8 48 1 1/3 1.9 15 29 20 30 10 23 BH *O11L6B CFO4K6E -PFV 208 -230 60 8.6 59.2 1 1/15 0.5 15.0 20.0 15 25 7 15 BH *011L6C CF04K6E -TF5 200 -230 3 60 3.9 52.0 1 1/15 0.5 15.0 20.0 15 20 8 15 B11*014L6B CF06K6E -PFV 208 -230 1 60 10.3 59.2 1 1/15 0.5 15.0 20.0 20 25 4 15 BH *014L6C CF06K6E -TF5 200 -230 3 60 6.3 52.0 1 1/15 0.5 15.0 24.0 15 25 9 19 BH*025L6B CF09K6E -PFV 208 -230 1 60 15 87.0 2 1/15 1 20.0 29.0 30 40 6 23 BH *025L6C CF09K6E -TF5 200 -230 3 60 9.2 72.2 2 1/15 1 15.0 21 20 25 7 15 BH*031L6B CF12K6E -PFV 208 -230 1 60 17 105.0 2 1/15 1 22.3 37.5 35 50 12 30 BH *031L6C CF12K6E -TF5 200 -230 3 60 10.7 85.0 2 1/15 1 15.0 28.8 25 30 7 23 BH *031L6D CF12K6E -TFD 460 3 60 5.3 42.0 2 1/15 1 15.0 23.8 15 25 A A Model Number BH *005112B •Port Number; ART82C1 -CAV Power Supply Compresspr Volts . _Ph ..Hz' .., H1-A .: LFlA 208 -230 1 60 5.9 30 EY,Ap'r Def rpst Fan Mplor; jVlCA ` MOPQ Fah Hepte,r flty 1-1P .FLA. :.., itt;,, l A$C. Llec ..AMPS . 7il -0, 1 1/15 0.5 15 20 15 20 8 15 BH *008H2B RS64C2 -CAV 208 -230 1 60 6.9 37 1 1/15 0.5 15 20 15 20 8 15 BH *010112B RS70C1 -PFV 208 -230 1 60 6.3 34.2 1 1/15 0.5 15 20 15 20 7 15 BH *010112C RS70CI -TFC 208 -230 3 60 4.2 31 1 1/15 0.5 15 20 15 20 8.6 15 BH *015112B CR18K0-PFV 208 -230 1 60 8.1 41 2 1 /15 1 15 24 15 25 6 19 BH *015112C CRI8KO -TF5 208 -230 3 60 4.9 40 2 1/15 1 15 24 15 20 7 19 BH *015H2D CR18KQ -TFD 460 3 60 2.8 23 2 1/15 1 15 20 15 20 A A BH *020H2B CR24KO-PFV 208 -230 1 60 12.2 70.5 2 1/15 1 20 29 25 30 6 23 BH *020112C CR24KQ -TF5 208 -230 3 60 6.7 40 2 1/15 I 15 24 15 25 9 19 BH *020H2D CR24KQ -TFD 460 3 60 3.6 28 2 1/15 1 15 20 15 20 A A BH *029M2B CR371C0 -PFV 208 -230 1 60 16.7 100.3 2 1/15 1 21.8 38 35 50 12 30 BH *029M2C CR37KO -TF5 208 -230 3 60 9.9 85 2 1/15 1 15 38 20 40 12 30 BH *029M2D CR37K0 -TFD 460 3 60 5.0 39 2 1/15 1 15 15 15 25 A A BH *030112B CR37KO -PFV 208 -230 1 60 16.7 100.3 1 1/3 3.5 24.3 38 40 50 12 30 BH *030112C CR37KQ -TF5 208 -230 3 60 9.9 85 1 1/3 3.5 20 38 25 40 12 30 BH *030H2D CR37KQ -TFD 460 3 60 5.0 39 1 1/3 1.9 15 24 15 25 A A BH *040112B CR53KO-PFV 208 -230 1 60 26.0 140 1 1/3 3.5 36.0 48.0 50 60 12 35 BH *040H2C CR53KQ -TF5 208 -230 3 60 16.3 107 1 1/3 3.5 23.9 38 40 50 12 30 BH *040H2D..._CR53KQ- TFD 460_...._3---- BH *050H2B CRN5 -0500 -PFV 208 -230 1 60 60 ..._.5.1 -- 30.8 55•-- 142.0 ._._1......_.1 __._1_9._._ 1 1/3 3.5 42 - .29._.....15 .._.. 59 50 30 11 12 23 47 60 BH *050H2C CRN5 -0500 -TF5 208 -230 3 60 19.2 130.0 1 1/3 3.5 28 40 45 50 12 30 BH *050H2D CRN5-0500 -TFD 460 3 60 8.7 65.0 1 1/3 1.9 15 29 20 30 10 23 LLl Electrical Data - Hermetic Compressors = T for Outdoor, N for Indoor, B for Bohnmizer, S for Beacon IITM Per UL and NEC, RLA values have been calculated by dividing the Maximum Continuous Current (MCC) by 1.56. A Power supplied by customer. 10 t Consult factory for 50 HZ applications. Air Defrost Models Electric and Hot Gas Defrost Models No. of Fans Dimensions (Inches / mm) A B C D 6 FPI 6 FPI 4 FPI 040 035 - 1 29.50 749.3 17.25 438.1 - - 052 040 - 1 29.50 749.3 17.25 438.1 - - 065 047 041 1 29.50 749.3 17.25 438.1 - - 070 - - 245.50 1,155.7 33.25 845.0 - - 090 065 - 2 45.50 1,155.7 33.25 845.0 - - 104 - - 2 45.50 1,155.7 33.25 845.0 - - 120 075 068 2 45.50 1,155.7 33.25 845.0 - - 130 090 080 2 45.50 1,155.7 33.25 845.0 - - 140 120 102 3 61.50 1,562.1 49.25 1,251.0 - - 156 - - 3 61.50 1,562.1 49.25 1,251.0 - - 180 140 - 3 61.50 1,562.1 49.25 1,251.0 - - 208 160 - 4 77.50 1,968.5 65.25 1,657.0 - - - 180 136 4 77.50 1,968.5 65.25 • 1,657.0 - - 260 200 170 5 93.50 2,374.9 81.25 2,064.0 48.63 1,235.1 32.63 828.7 312 240 204 6 109.50 2,781.3 97.25 2,470.0 48.63 1,235.1 48.63 1,235.1 370 280 235 6 109.50 2,781.3 97.25 2,470.0 48.63 1,235.1 48.63 1,235.1 4 3/16' 106 ow NOTE: Hanger brackets will accept 3/8' / 9.5 mm hanger rods. IP ww 3/4'144114 N Donn Comedian - 13 - 1 314• 44 ow Dimensional Data For All Models ensonalData u I ; a :,qr ;1 ' E: ,i � 'a 22 outs 7/8' Electricd Knockouts 2118' 34a m 7 33 am O )11$ ALIO CUOMO AI 111:011110•111 elT 7. NMI R1l 1•Mle it LI 3/4' J05 rem 44 ww 14 718' 377 my , . ::;. TJTUI:1:/Altratts 4■Cit! ,-- -' Model Size ' ; :. :.Capacity : ; :-:, '• -I --:. :. ;:; . :' :000 foi 6,c Tb:* 425?F'SST/-4°C;SST ; ; : ' ' •' Fan Data.. • .' , . ; ; PSC, PSC-TE Motor Data ' ' . (Total Amps/Watts) No. . .. - CFM / rn ; : NO: ;; ;: ':.:,. , ' ' HP,. - : , 111: r.. : 1/60Watts ; 208-230/ 140 Watts 460/ 1/60Weitts ADT 040 4,000 1,170 730 1 ,240 1 1/15 1.0 82 0.5 91 0.4 117 ADT 052 5,200 1,520 700 1,189 1 1/15 1.0 82 0.5 91 0.4 117 ADT 065 6,500 1,900 650 1,104 1 1/15 1.0 82 0.5 91 0.4 0 117 ADT 070 7,000 2,050 1,460 2,481 2 1/15 2.0 164 1.0 182 0.8 234 ADT 090 9,000 2,640 1,400 2,379 2 1/15 2.0 164 1.0 182 0.8 234 ADT 104 10,400 3,050 1,400 2,379 2 1/15 2.0 164 1.0 182 0.8 234 ADT 120 12,000 3,500 1,300 2,209 2 1/15 2.0 164 1.0 182 0.8 234 ADT 130 13,040 3,810 1,300 2,209 2 1/15 2.0 164 1.0 182 0.8 234 ADT 140 14,000 4,100 2,100 3,568 3 1/15 3.0 246 1.5 273 1.2 351 ADT 156 15,600 4,570 2,100 3,568 3 1/15 3.0 246 1.5 273 12 351 ADT 180 18,000 5,270 1,950 3,313 3 1/15 3.0 246 1.5 273 1.2 351 ADT 208 20,800 6,100 2,800 4,758 4 1/15 4.0 328 2.0 364 1.6 468 ADT 260 26,000 7,620 3,250 5,522 5 1/15 5.0 410 2.5 455 2.0 585 ADT 312 31,200 9,140 3,900 6,627 6 1/15 6.0 492 3.0 546 2.4 702 ADT 370 37,000 10,840 3,900 6,627 6 1/15 6.0 492 3.0 546 2.4 702 ;..::• y.. , APT: ; mlidel Size * Capacity ., . ; - . BTUH / Watts . ; 10°F TD/ 6°C TD 445°F SST/-4°C SST , .• . ; Fan Data ; ' Shaded Rile Motor Data (Total Amps/Watts) CFM / m No. .HP ; 115/ 1/60/Watts 208430/ 1/60/Watt ADT 040 4,000 1,170 730 1,240 1 1/15 1.8 116 1. 1.0 122 ADT 052 5,200 1,520 700 1,189 1 1/15 1.8 116 1. 1.0 122 ADT 065 6,500 1,900 650 1,104 1 1/15 1.8 1. 116 1.0 122 ADT 070 7,000 2,050 1,460 2,481 2 1/15 3.6 232 2.0 2. 244 ADT 090 9,000 2,640 1,400 2,379 2 1/15 3.6 232 2.0 2. 244 ADT 104 10,400 3 050 1,400 2,379 2 1/15 3.6 232 2. 0 244 ADT 120 12,000 3,500 1,300 2,209 2 1/15 3.6 232 2.0 244 ADT 130 13,000 3 ,810 1,300 2,209 2 1/15 3.6 232 2. 0 244 ADT 140 14,000 4,100 2,100 3,568 3 1/15 5.4 348 3.0 366 ADT 156 15,600 4,570 2,100 3,568 3 1/15 5.4 348 3.0 366 ADT 180 18,000 5,270 1,950 3,313 3 1/15 5.4 348 3.0 366 ADT 208 20,800 6,100 2,800 4 ,758 4 1/15 7.2 464 4. 0 488 ADT 260 26,000 7,620 3,250 5 ,522 5 1/15 9.0 580 5. 0 610 ADT 312 31,200 9,140 3,900 6,627 6 1/15 10.8 696 6.0 737 ADT 370 37,000 10,840 3,900 6,627 6 1/15 10.8 696 6. 0 732 e Air Defrost Capacities ADT Air Defrost Models 60 Hz. with Shaded Pole Motors •Enqrgy ADT Air Defrost Models 60 Hz. with PSC Motors Solutions 5 LET /LLE ; w `Model Size ' No of • ` ';.;., Fans ;.• Connections (inches) , Approx Net Wt... ',Lbs 611 :1 Suction* External Equalizer ; Drain , .- , ,.. ADT 040 1 1/2 OD 6 • 'iiod. 1/4 OD 3/4 MPT 28 13 LET 035 1 1/2 OD 5/8 ID 1/4 OD 3/4 MPT 24 11 LET 040 1 1/2 OD 5/8 ID 1/4 OD 3/4 MPT 26 12 LET 047 1 12 OD 5B ID 1/4 OD 3/4 MPT 29 1a LET 065 2 1/2 OD 5/8 ID 1/4 OD 3/4 MPT 43 an LET 075 2 12 OD 7B ID 1/4 OD 3/4 MPT 45 21 LET 090 2 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 48 22 LET 120 3 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 60 28 LET 140 3 1/2 OD 7/8 ID 1/4, OD 3/4 MPT 62 29 LET 160 4 1/2 OD 1 -18 ID 1/4 OD 3/4 MPT 81 37 LET 180 4 1/2 OD 1-1/8 ID 1/4 OD 3/4 MPT . 84 39 LET 200 5 1/2 OD 1-1/81D 1/4 OD 3/4 MPT 101 46 LET 240 6 12 OD 1 -1B ID 1/4 OD 3/4 MPT 121 55 LET 280 6 12 OD 1 -18 ID 1/4 OD 3/4 MPT 124 57 ADT 370 6 1/2 OD 4 FPI Models 1/4 OD 3/4 MPT • LLE 041 1 1/2 OD 5/8 ID 1/4 OD 3/4 MPT 28 13 LLE 068 2 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 44 21 LLE 080 2 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 47 22 LLE 102 3 1/2 OD 7B ID 1/4 OD 3/4 MPT 59 27 LLE 136 4 1/2 OD 1 -1/8 ID 1/4 OD 3/4 MPT 80 37 LLE 170 5 1/2 OD 1 -1B ID 1/4 OD 3/4 MPT 100 46 LLE 204 6 1/2 OD 1 -1/8 ID 1/4 OD 3/4 MPT 120 55 LLE 235 6 1/2 OD 1 -1B ID 1/4 OD 3/4 MPT 123 56 A DT... , . Model Size No of Fans Connections (Inches) Approx. Net. Wt. Lbs / (;a Coll. Inlet Suction* External . Eaualizer Drain ADT 040 1 1/2 OD 5/8 ID 1/4 OD 3/4 MPT 28 13 ADT 052 1 12 0D 5B ID 1/4 0D 3/4 MPT 31 15 ADT 065 1 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 34 16 ADT 070 2 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 45 21 ADT 090 2 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 48 22 ADT 104 2 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 49 23 ADT 120 2 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 51 24 ADT 130 2 1/2 OD 7/8 ID 1/4 OD 3/4 MPT 53 25 ADT 140 3 12 OD 7/8 ID 1/4 OD 3/4 MPT 63 29 ADT 156 3 12 OD 7/8 ID 1/4 OD 3/4 MPT 67 31 ADT 180 3 12 OD 78 ID 1/4 OD 3/4 MPT 69 32 ADT 208 4 1/2 OD 1 -1/8 ID 1/4 OD 3/4 MPT 82 38 ADT 260 5 1/2 OD. 1 -1/8 ID 1/4 OD 3/4 MPT 103 47 • ADT 312 6 1/2 0D 1 -18 ID 1/4 0D 3/4 MPT 124 57 ADT 370 6 1/2 OD 1 -3/8 ID 1/4 OD 3/4 MPT 127 58 Air Defrost Physical Data Electric Defrost Physical Data * Suction connection is swedged to directly accept piping -11- ARarict�;?� ; nssr'i i'�'�,?:.. sF: !�,' ti �:�,,, 3y� ,••,� , ', 'f,.a,�.. �: � = 1?tf:�a,&++ .1x vh °•,..�, sd J.c awd.dTd�. � >"� 'AQProi�2l'.y� -. - ` r�*:..70E150' f� W iGRC'6F'ii KM- 500MRH Cuber 450 lbs. i^ & R =6F .mx KM- 630MRH Cuber 600 lbs. NRC:6F. a± F- 1001MRH Flaker 920 lbs. `;°! KML- 600MRH Cuber 635 lbs. GRg*12Fri= KM- 900MRH Cuber 860 lbs. ,. L1RCxa2 ,.., _ . r_ .. �Ft•. KM- 1300SRH Cuber 1193 lbs. e,UR Q12Fa. KM 1300MRH Cuber 1296 lbs. itioc 20E: : :: F- 2000MRH113 Flaker 2000 lbs. it1 @.0 „igQF4 KM- 1600MRH Cuber 1486 lbs. 6 t.0 C20Fr; KM- 1600MRH3 Cuber 1524 lbs. ?4;URC2 ,.;” KM- 1600SRH Cuber 1430 lbs. rkJRG ;2QF KM- 1600SRH3 Cuber 1461 lbs. is i, 41.1Adf2,0Fii; KM- 2000SRH3 Cuber 1865 lbs. iURG24EY: ' KM- 2400SRH3 Cuber 2330 lbs. ais,w,:c.i.3`S!"' I.Ysa`�t,a.,...a.-4. �'. `:11ibd1' i -LIala v.!...v.: Series URC -6F Remote Condenser URC -24F Remote Condenser URC -6F Air - Cooled URC -7F Air - Cooled URC -12F Air - Cooled URC -20F Air - Cooled URC -24F Air - Cooled �* � • i NIZAKI AMERICA, INC. ;S., Peachtree City, GA 30269 TEL 1- 800. 438.6087 �.,CE MA*f-llNr_ ® Remote Condensers for KM Series Cubers and F Series Flakers 0 Quiet operation © Improved efficiency ® Energy savings 0 Weather resistant cabinet for longer life o May be installed outdoors up to 55 feet from icemaker using a pre - charged tubing kit 0 For installations exceeding 55 feet, contact Factory Service Department Icemakers sold separately Reliability is a beautiful things FAX 1- 800. 345.1325 www.hoshizaki.cam z 1 Z , ce W J U U O N 0 : W= J N W O . = l. W I z O z tr- uj D p U 0 — 0 l—• w � O lii z U N 0� O z URC -F SERIES DIMENSIONS (Inch - CONNECTIONS 21 • ... �`: : s . P1s�t'e'� n1.ir"1r''r REMOTE CONDENSERS URC -6F (AIR - COOLED) URC -7F (AIR - COOLED) URC-1 2F (AIR- COOLED) "t 20':Igriptti ? 351; ngth ,; R404- 2046 -2 R404- 3546 -2 R404- 2046 -2 R404- 3546 -2 R404- 2068 -2 R404 -20610 ELECTRICAL 115/60/1 (Connection to Icemaker) URC•24F: 208- 230V/60/1 (Connection to Icemaker) R404- 3568 -2 R404 -35610 NA NA R404- 5568 -2 R404 -55610 60 lbs. (100 lbs. ) - 11 - 5 - 16S. 155 lbs. R404 -20610 R404 -35610 R404 -55610 210 lbs. WARRANTY When used with KM Series Cubers: THREE YEAR - Parts & Labor, entire unit FIVE YEAR - Parts on: Air - Cooled Condenser Warranty valid in United States, Canada, Puerto Rico, & U.S. Territories. Contact Factory for Warranty in other Countries. OPERATING LIMITS Ambient Temp Range -20 to +122'F Voltage Range 104 - 127V URC -24F- (187 -253V) Icemakers sold separately � F 18 32t3/le 21n " � 3 "I'm .� 24 3/8 Discharge line • )• -- 21 /Hi 114 Liquid refrigerant line 3413111 Electrical conduit — access 3/8 Discharge 1/4 Liquid Ilne refrigerant line URC -20F (AIR-COOLED) URC -24F (AIR - COOLED) Electrical conduit access 2314 23/4 18ve When used with F Series Flakers: TWO YEAR - Parts & Labor, entire unit FIVE YEAR - Pars on: Air - Cooled Condenser 81A Hwv 74 S PAach$rae City AA An9Rn PINIIIIIImmmiummommummunr © HOSHIZAKI AMERICA, INC. I.--3511ne- 4"tr 18trs 3- - ` 3713/m r- - 4635 318 Liquid refrigerant line 5t 22 37 4075 Electrical conduit _access 487111 5/8 Discharge 3/8 Liquid line refrigerant line Electrical conduit access 518 Discharge line 1/4 Liquid refrigerant line 1- Rnn- 41A -AnA7 TFI 77n -4R7 -9'11 IM For use with KM Series Cuber and F Series Flaker • Quiet operation and energy efficient Electrical conduit access 1/2 Discharge line R -404A REFRIGERANT For best performance allow 24 inch clearance for air circulation For best performance the Remote Condenser should not be more than 33 feet above the KM Icemaker or no more than low it. 'stances are measured from fitting to fitting. Discharge line ICEMAKER Liquid refrigerant line ICE STORAGE BIN Liquid Refrigerant Line We reserve the right to change specifications without notice. FAY 1•Rnn.94F.199F • hnahPool.1 mm REFRIGERANT CHARGE All components are pre - charged with quick disconnect fittings REMOTE CONDENSER INSTALLATION ON ROOF Electrical Conduit Access Discharge Line 21/2 inch Diameter hole in roof for tubing. Seal after installation to prevent leaking. Electrical connections must meet all local codes. Remote Condenser fan motor connection Icemaker and Storage Bin sold separately PRE - CHARGED TUB iNG KITS (Sold Separately) Refer to SPECIFICATIONS tabl e to determine appropriate Tubing Kit Number f or Remote Condenser Unit specified Printed In U.S.A. < • 1 - 00 • ° CO 111 11J -1 1- CO u_ uj 0 2 g -7J u.. < co I Z 0 Z Dc 111 w O co O — 0 1— 1.1J uj I- . Z w C.) — 0 ▪ 1— z DEPARTMENTS: 1° 4 °7 Buildi ivi ion Public Works ❑ PERMIT COORD COI PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PROJECT NAME: M04 -177 7- ELEVEN DATE: 10 -05 -04 SITE ADDRESS: 14207 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # afterlbefore permit is issued 't to - Fire Prevention Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -07 -04 Complete Ed Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO TING: Please Route Structural Review Required ❑ No further Review Required El REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -04 -04 Approved ❑ Approved with Conditions [y'J Not Approved (attach comments) ❑ PP ( ) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slIp.doc 2-28-02 PERMIT COORD COPY 03 -01 -2005 PETER CRELLEY P.O. BOX 33370 SEATTLE, WA 98133 RE: Dear Permit Holder: Stefania Spencer, Permit Technician City of Tukwila Department of Community Development Steve Lancaster, Director . Permit No. M04 -177 14207 TUKWILA INTERNATIONAL BL TUKW Steven M. Mullet, Mayor In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.. . Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04/12/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. xc: Permit File No. M04 -177 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 - 431 -3665 U O N G w W N LL W O! u- a O W . w. U 0 O tt W W` U' u. H ' LL •Z 0 .*, ai m 6 0 0 0 co 0 w W I : CO u. w g .73 u. u) I- 0 Z ju n o 0- 1 I- W uj LI- Z "e _02 • ( ••• i ytt ......•••••••••■•••••••••■...... ST - , ST . . 3/0 v): Ifl ANS 7 • • olt4 ;441. --••• - - - ••••••■■••••••••••••••.•••• • SITE PLAN • •,•-• • r ".".••••••••••.... SEPARATE REQUIRICI Falb a Mechanical • ef Elscbiai It Plumbing lir Gss Piping Clly Of 'naiads WILDDIG DIVISION ROOF PLAN SCALE: 1/20 = 4000 . , 4 4 *.• • • z • , - .11 •••••••••••••••• MI. .- " • • • r" • •••••••••••••••••■•• •".•••••• ••••••‘,1•1111111•••••••••••••••121111M,...,•••••,,411.11,,gp,,,m,•-• xy. • .dgo. -- • A« PROPERTY LINE • Replace the existing rooftop refrigeration condensing unit • and indoor equipment with new. "Like-for-Like" Replacement • FUEL ?vrft?S g ill low rani* Noe Cliv arida* allAILOING 01111101 • • . , \ REVIEWED FOR ' CODE COMPLIANCE PATIROVS OCT - 8 Z004 *7. rim aim appeal Is subject to SAWS 1111d Maw Appowl caulndlon dearments doss not eagle Illmelsiondwi aloof ale � alma IWO dippioved Add I. • City ut Tukwila ViLOING giVisiON neceveD CITY OF TUKWILA OCT 0 5 2004 PERMIT CENTER • • /10 • • s . ••• • • Iw ••••• ■••■••••1611 ~PS, •111.16•01•••••••••.••••••••‘ 1,11•••• REVISIONS 0/1/0* C DRAWN r DATE . VS S1/43 CONTENTS , M4