City f Tukwila
Parcel No.: 7888900154
Address: 18340 OLYMPIC AV S TUKW
Suite No:
Tenant:
Name: EXTERIOR SYSTEMS
Address: 18340 OLYMPIC AV S, TUKWILA WA
Owner:
Name: SAMMIS PCA PARTNERS
Address: C/O THE SAMMIS CO., 309 S CLOVERDALE ST
Contact Person:
Name: DAVE EVANS
Address: 1411 R ST NW, AUBURN WA
Contractor:
Name: AMBIENT CONTROL CO INC
Address: 1020 S 344 ST, SUITE 203, FEDERAL WAY WA
Contractor License No: AMBIECC101PW
DESCRIPTION OF WORK:
INSTALLATION OF A 2.5 TON HEAT PUMP WITH DISTRIBUTION.
Value of Mechanical: $8,136.00
Type of Fire Protection:
Furnace: <100K BTU 1
>100K BTU 0
Floor Furnace 0
Suspended /Wall /Floor Mounted Heater 0
Appliance Vent 0
Repair or Addition to Heat/Refrig /Cooling System.... 0
Air Handling Unit <10,000 CFM 1
>10,000 CFM 0
Evaporator Cooler 0
Ventilation Fan connected to single duct 0
Ventilation System 0
Hood and Duct 0
Incinerator: Domestic 0
Commercial /Industrial 0
doe: IMC- Permit
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: ci.tulnvila.wa.us
MECHANICAL PERMIT
* *continued on next page **
M04 -185
Permit Number:
Issue Date:
Permit Expires On:
EQUIPMENT TYPE AND QUANTITY
Phone: (206)763 -6200
Phone: 206 - 510 -7648
Phone: 253 - 661 -5844
Expiration Date:10 /25/2005
Steven M. Mullet, Mayor
Steve Lancaster, Director
M04 -185
11/08/2004
05/07/2005
Fees Collected: $288.05
International Mechanical Code Edition: 2003
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood /Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 11 -08 -2004
Permit Center Authorized Signature:
doe: IMC- Permit
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: ci.tukwila.wa.us
M04 -185
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: M04 -185
Issue Date: 11/08/2004
Permit Expires On: 05/07/2005
Date: /f` - 2 '
I hereby certify that I have read and examined is permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit.
Signature: _ _ _ + _ Date: g" � OY
Print Name: , V 77r.J /,v 0 t� (/irT s
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
Printed: 11 -08 -2004
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 7888900154
Address: 18340 OLYMPIC AV S TUKW
Suite No:
Tenant: EXTERIOR SYSTEMS
1: ** *BUILDING DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
Permit Number: M04 -185
Status: ISSUED
Applied Date: 10/22/2004
Issue Date: 11/08/2004
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: Readily accessible access to roof mounted equipment is required.
5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread
index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed
spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply
to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or
floor finish.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Conditions
* *continued on next page **
M04 -185
Printed: 11 -08 -2004
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any
regulating construction or the performance of work.
doc: Conditions
M04 -185
of law and ordinances
Date: /7
other work or local laws
Printed: 11 -08 -2004
w
SITE LOCATION
Q 2, King Co A ssessor's Tax No.:,� ' /e. / ?
Site Address;.__ U / L l .-�n') (- n t L 1�7 Suite Number: Floor:
Tenant Name: �X I1E'YLt��. S 5 New Tenant: Yes ❑ ..No
Property Owners Name: c . 7 c- c—b.1�vk. oLY M Ct (.
Mailing Address: 5 , 5 1 Y �k3c—ttt. Q I .5r7PCM. c— CAA- - . T! 4z3
CONTACT PERSON
Name: IL) Env.) S
Mailing Address:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
W
TUKWILA
W
Building Permit No.
Mechanical Permit No. MO L* -
Public Works Permit No.
Project No.
(For of we use onl ')
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
City State Zip
Day Telephone: S - 7
t wA - 9 S( 0 9
City State Zip
E -Mail Address: Fax Number:
GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page)
Company Name: 1 � �. ) rN4 u) r� � / 1 � 1 � � Ge�a�1�
Mailing Address: ( 5 [. L( , ,7 y 6�ti4 C: oh4 - 9Q I
Contact Person: I4/4'0.) /
E -Mail Address:
Contractor Registration Number: , .L? 4/2C7 Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address;
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name: A/ / 4—
Mailing Address;
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
\applicationslpcnnit application (74004)
Pace I
City State Zip
Day Telephone:
Fax Number:
State
Zip
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall /Floor
Mounted Heater
Ventilation System
Wood /Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood
Water Heater
50+ HP /1,750,000 BTU
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator– Comm/Ind
Other Mechanical
Equipment
i
r
MECHANICAL PERMIT INFORMATION — 206 -431 -3670
i
MECHANICAL CONTRACTOR INFORMATION
Company Name: eJ1et-VT C t�til Z`CZ.O` . 1� L
Mailing Address: I LI I I 1 t)T_ . P 1,1 - q a
City State Zip
Contact Person: Dal Evik5 Day Telephone: 2oea — 510 - 4
E -Mail Address: n ,� /� Fax Number: 2 -�37( -cig3c(
{t
Contractor Registration Number: t'11 * 101 P.") Expiration Date: 10
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
a et Cdr 04 m %kk - Pup. P L T%
�1�i�.�Q�sna1 -
Sang; Residential: New ❑ Replacement ❑
Commercial: New Ce Replacement ❑ p
Fuel Type: Electric Gas ❑ Other: 1 T ( 1
Indicate type of mechanical work being installed and the quantity below:
PERMIT APPLICATION NOTES = Applicable to all permits in this application
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review– Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE : • ' -. HORIZED AGENT:
Signature. l
Print Na . : a/6 .
Mailing Address: /'7/7 ._ J 1 N,c.J
Date Application Accepted:
la pplications\permit application (7-2004)
/o
Pace 4
Day Telephone: 2 J S -
cam-_ �eLX.)i
City State
Date: /0 _C - - .S1
Zip
Date Application Expires:
Staff I ' ials:
i
Receipt No.: R04 -01500
Initials: SKS
User ID: 1165
ACCOUNT ITEM LIST:
Description
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 7888900154 Permit Number: M04 -185
Address: 18340 OLYMPIC AV S TUKW Status: APPROVED
Suite No: Applied Date: 10/22/2004
Applicant: EXTERIOR SYSTEMS Issue Date:
Payee: AMBIENT CONTROL CO. INC.
TRANSACTION LIST:
Type Method Description Amount
Payment Check 18600.
MECHANICAL - NONRES
RECEIPT
Payment Amount: 212.05
Payment Date: 11/08/2004 01:08 PM
Balance: $0.00
212.05
Account Code Current Pmts
000/322.100 212.05
Total: 212.05
-6736 11/09 9716 TOTAL 212.05
Printed: 11 -08 -2004
Parcel No.:
Address:
Suite No:
Applicant:
Receipt No.:
Initials:
User ID:
Payee:
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
7888900154
18340 OLYMPIC AV S TUKW
EXTERIOR SYSTEMS
R04 -01441
BLH
ADMIN
DAVID EVANS
TRANSACTION LIST:
Type Method Description
Payment Cash
ACCOUNT ITEM LIST:
Descr
MECHANICAL - NONRES
PLAN CHECK - NONRES
000/322.100
000/345.830
RECEIPT
Account Code
Permit Number:
Status:
Applied Date:
Issue Date:
Payment Amount: 46.00
Payment Date: 10/22/2004 01:07 PM
Balance: $212.05
Amount
46.00
Current Pmts
.39
45.61
Total: 46.00
M04 -185
PENDING
10/22/2004
6246 i0/22 97:L$ TOTAL 4,4.00
Printed: 10 -22 -2004
Pr
2_,?Or_S
Type of Inspect' n:
/1.4
Addrgg " r
1 ?4 vn 0 I (j.�fl44'Y - i4'U
Date Called:
rs + 11 D y
Special uctions: U
Date Wanted: ,
! Vo Y p.m.
Requester:
' gYR ----. 'Ktf(fl
prior to approval.
Approved per applicable codes.
orrections required
COMMENTS: •
A ) -9 w
it , 14
�, r) 'e T-c
.
0\Z 4r.) Pt
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PER
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20
$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
I l �ceipt No.:
'Date:
670
Pro' t
("")
Type of Inspectiort:
Address:
/ ;?!.--:".• '70 l L
/
, I; , /II' S
Date Called:
/
Special Instructions: v
'
Date Wanted : t ie-2/
p.m
Requester:
P ( -4 -- M .92 2 _k q cf'
D Approved per applicable codes.
'Inspecto
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
06)431 -3670
orrections required prior to approval.
COMMENTS:
1 t I
-Pty IF ,r�.,(
0
N. i4 e k 1:3c
wl
PP
r
�,1i t In sr C 1
v - P( -'r1 v (r� � ► � prcilin"
hiss b 4 6 _ "►�,�
L IDate: t I _011
El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Project:
�X�4 S. c�'e.W
Typ o� I nspection:
�1J�c:, a.,r,SvL1:1o
Date Called:
)k-10-021
Ad ress: f
" C)I\ v k
Special Instructions:
Date Wanted:
a.m.
p.m•
Requester:
Phone No:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable. codes.
Vto'± I gS
PER
TN
(206)431 -3670
Corrections required prior to approval.
COMMENTS:
Inspector
Date: 11 -10�
0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
!Date:
1, " s �t �v'1:1�� ;;5 r.rN:;l" ad;Fhtis! +'p ^..�,.�7.•YS .b..
v..
Project:
- >d - et ts % 19 r S-\ PAY\
Type of Ind
TO ■ Mik k 1-\
Address:
1 nHO 01 kv1 k 41)
Pt( 11-10-0)-1
Date Called:
Special Instructions: 1
Date Wanted:
air.
p.m.
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
1 I g g
PE
T NO.
(206)431-3670
Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
e Rn . c
s-e R.. fr)rt I
Vv\ 1, a, - 2, e
'Inspector:
r ate: 10
ri $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
" --1 paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
COMMENTS:
/ E/ee /c/ A4 / 4rm ;7` r- x(i�� -tdy""
Type of Inspe on; , / 0 r-/
- .S r ✓ /.to A/ 4 ✓e= f, 2,1) C- A ` 14 , \-ti
r- cc?.S / l 7t/v, 74-
4 -1 - �t/ filth Z /A1, -i -- JJ /./ k
J
c Al J)2/ '7 • 0 /1 l is'yl./ /l/l4.S�'
___5
to _ c S'.. S1, v 0 Z/'. llec " /,--/ l
/ i c� /
4 If Ste°/ h )iS-/ A7 ��c1�7
1- rid
,---1-0
Akir --4 _ )/ J J ic/ d)i /( //‘,15 %
,% / 4-
Pro(j..Ceect:
Type of Inspe on; , / 0 r-/
Address:
/rteW Z — (.. : -./..,7 . .4.e--r....
;.. i . f� , v S.
Date Cal ed•
/ /
Special Instructions: (
'
Date Wanted:
/7 %
m_
5 •m•
Requeste r
^".
Phone No � : s /���
G i 7 ' - Og'
r / 7/ `/
...." � / f! . J�
INSPECTION RECORD
Retain a copy with permit
INSPECTION N9.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
ED Approved per applicable codes.
(206)431 -3670
Corrections required prior to approval.
REINSPECTION FEE R QUIRED. Pr • r to inspection, fee must be
d at 6300 Southcenter Blv.., Suite 100. Call to schedule reinspection.
eipt No.:
Date:
ORDER NO.:
ARCHITECT:
PURCHASER:
SUBMITTED BY:
YORK®
It's Time to Get Comfortable"'
SUBMITTAL DATA
FOR: Approval
PROJECT: SOUTH CENTER SOUTH
18340 OLYMIC AVE S.
KRAFT ARCHITECS
RREEF
AMBIENT CONTROL CO. INC.
JYORK'
It's Time to Get Comfortable'
DATE: 10/22/2004
REVIEWED FOR
COD CE
E
APPROV' 0
NO v
— 1 2004
R 4- f_ Tukwila
RECEIVED ECEIVED
CITY OF TUKWIL. C OF TU
OCT 2 2 2004 AUG 7003
PERMIT CENTER PE • C ER
•
Data
10/22/2004
Project Name
SOUTH CENTER SOUTH
Client / Purchaser
Order No
( 1
QTY SCHEDULE NO MODEL NO. DESCRIPTION
1 B1 HA030A06 208 -1 -60 Heat Pump Unit
NOTES:
Company logo goes here...
Submittal Summary Page
(Equipment only. Refer to Quotation page or Schedules for selected accessories.)
ESP2003 V3.2 July 2004 Subject to change without notice • Check local codes
II
•
3�YORK'
It's Time to Get Comfortable"
Project Name SOUTH CENTER SOUTH
Architect
Engineer
Purchaser
Submitted By
QUANTITY: 1 UNITS DESIGNATION: Schedule No:
COOLING PERFORMANCE
Total Capacity
Sensible Capacity
Efficiency (at ARI)
Outdoor DB Temp
Entering DB Temp
Entering WB Temp
Leaving DB Temp
Leaving WB Temp
Power Input (w /o blower)
Elevation
Sound Power
28.4
21.7
10.20
95.0
79.7
66.6
59.6
57.6
3.16
0
79
MBH
MBH
SEER
F
F
F
F
F
KW
Ft
Dbels
HEATING PERFORMANCE
Electric Heat
Capacity
Power Input
Capacity at 47 Deg. F
Capacity at 17 Deg. F
COP at 47 Deg. F
COP at 17 Deg. F
N/A
N/A
29.0
14.7
3.2
2.0
MBH
KW
MBH
MBH
SUPPLY AIR BLOWER PERFORMANCE
Total Supply Air
Outside Air
External Static Pressure
Duct Connection Location
Blower Speed
Motor Rating
Power Input Requirement
1000 CFM
100 CFM
0.67 IWG
Bottom
High
0.5 HP
0.47 KW
ELECTRICAL DATA
Power Supply 208 -1 -60
Total Unit Ampacity 18.7 Amps
Maximum Overcurrent Device
Fuse Size 25 Amps
HACR Circuit Breaker 25 Amps
DIMENSIONS & WEIGHT
Height 34 in Width 49 in Depth 48 in
Total Weight (incl factory options) 355 Lbs
CLEARANCES
Front 12 in Back 0 in
Bottom 1 0 in Top 36 in
Left Side (filter access) 24 in
Right Side (outdoor coil) 24 in
1. Units may be installed on combustible floors made from wood
or class A, B or C roof covering materials.
2. Units must be Installed out doors. Overhanging structures or
shrubs should not obstruct condenser air discharge outlet.
HEAT PUMP UNIT
18340 OLYMIC AVE S.
A 1 in. clearance must be provided between any combustible material
and the supply air ductwork for a Distance of 3 feet from the unit.
The products of combustion must not be allowed to accumulate
within a confined space and recirculate.
ESP2003 V3.2 July 2004 Subject to change without notice • Check local codes
Date 10/07/2004 Page 2
Order No
Model No: B1 HA030A06
GENERAL FEATURES
- Complete Factory Package, Tested, Charged, Wired
- Three -speed Direct Drive Blower Motor on all std. and hi -eff. model units
- Electronically Commutated Motor (ECM) on all ultra -eff. model units
- Hermetically Sealed Compressor
- Bottom or Side Air Duct Configuration Capability
- Low Voltage Relay Board With Terminal Strip
- Liquid Line Filter Drier
- 24 Volt Control Circuit with compressor lock out protection
- Permanently Lubricated Motor
- Suction Line Accumulator on Heat Pumps
- Ambient Modified - Time/Temperature Defrost Logic on Heat Pumps
- Copper Tube /Aluminum Fin Coils
- Easy Access to all Electrical Components
- Rigging Holes and Forklift Slots in Base Rails for Lifting
- Single Point Power Connection
- Powder Paint Finish That Meets ASTM -B117 750 hr. Salt
Spray Test Standards
- Agency Approvals - AGA & CGA on All Units
- Factory Warranty - all 10 SEER units and all 3 -phase units
- One Year Limited Parts on the Complete Unit
- Five Years on the Compressor
- Five Years on the Electric Heating Elements
- Factory Warranty - all 12 & 13 SEER singe -phase units
- Five Years Limited Parts on the Complete Unit
- Ten Years on the Compressor
- Five Years on the Electric Heating Elements
Aso
9001
CERTIFIED
YORK
It's Time to Get Comfortable"
0 UPGRADE SAFETY PACKAGE
HIGH VOLTAGE CONN.
1- 31/32" DIA. KNOCKOUT
LOW VOLTAGE CONN.
7/8" DIA. KNOCKOUT
SIDE SUPPLY
AIR OPENING
SIDE RETURN
AIR OPENING
CONDENSER
COIL
BOTTOM SUPPLY
AIR OPENING
Notes:
1.314
15
HIGH VOLTAGE CONN
7/8' DIA. KNOCKOUT
49-1/8
(OVERALL)
26.9/16
15
3.12
1 -3/4
28-1 /4 17 -1/4
22 1/4
28.3/0
3-3/4
14-1/2
HEAT PUMP UNIT
B1 HA030A06
BACK
SIDE RETURN
AIR OPENING
3-1/2
BOTTOM RETURN
AIR OPENING
1 -1/2
4-1/2
43.12 40.1 ,26-
FIELD INSTALLED ACCESSORIES
ANTI - RECYCLE TIMER 0 THERMOSTAT
MOTORIZED OUTDOOR AIR DAMPER (50 %)
0 Deg.LOW AMBIENT CONTROLS
ECONOMIZER w/ DRY -BULB CHANGEOVER
SINGLE ENTHALPY SENSOR
DUAL ENTHALPY SENSORS
FUSE KIT
ELECTRIC HEATER
ZONE CONTROLS
HAIL GUARD
8" HIGH ROOF CURB
14" HIGH ROOF CURB
FILTER FRAME AND FILTER
TRANSFORMER KIT
RECTANGULAR TO ROUND DUCT ADAPTERS
MANUAL OUTDOOR AIR INTAKE DAMPER (50 %)
ENERGY RECOVERY VENTILATOR
FRONT
A
(OVERALL)
2 -3/8
COMPRESSOR
SERVICE ACCESS
COMPARTMENT PANEL
REFRIGERANT
CONNECTIONS
ELECTRICAL/FILTER
SERVICE ACCESS
COMPARTMENT PANEL
47 -1 /4 HIGH VOLTAGE CONN.
1- 23/64" DIA. KNOCKOUT
(OVERALL)
UNIT CONDENSATE
CONNECTION 3/4" NTPI
(TRAP REQUIRED)
LOW VOLTAGE CONN.
718' DIA. KNOCKOUT
CONDENSATE
DRAIN 3/4' NPTI
ESP2003 V3.2 July 2004 Subject to change without notice • Check local codes
Date 10/07/2004 Page 3
Order No
UNIT SIZE
018 THRU 042
048 AND 060
e 22-1/2
FRONT
"A"
33 -1/2
41 -1/2
HIGH VOLTAGE
CONN. 1.31/32' x 7/8" DIA.
KNOCKOUT
Documents /routing slip.doc
2 -28.02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER:
PROJECT NAME:
M04 -185 DATE: 10 -22 -04
EXTERIOR SYSTEMS
SITE ADDRESS: 18240 OLYMPIC AVENUE SOUTH
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # afterTbefore permit is issued
DEPARTMENTS: /
Buil i vision �� Fire P re Prevention
Public Works ❑ Structural ❑
DETERMINA ON OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -26 -04
Complete Incomplete ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping El PW ❑ Staff Initials:
TUES /THURS R9UTING:
Please Route , U2U ( Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 11 -23 -04
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
�T CJOORD COPY
Planning Division
Permit Coordinator
Not Applicable ❑
DATE:
PACKAGED A/C UNIT SCHEDULE
MARK
EQUIPMENT-MAKE,
MODE, SIZE ,PERFORrvi
ELECTRICAL DATA
REMARKS
A0.1
N1Q()EL. YORK
D1NA030NO3606
HEATING •
ELIBOTRIOAL
20S-1-60
MAX FUSE SZE• $0
.
if
MINP.ILIIVI calcur AMP 21.7
,„. •
TOTAL WEIGI-4T:
395 L.
FILTERS
. ,
....-
L/417 CONTROLS.
.. PROGRAMMABLE NIGHT
SETBACK THERMOSTAT
MBH INPlfr. 45
MBH OUTPUT. 36
UUE%: 60 ,
.
COOLING ,
MBH TOTAL. 29 4 ,
MBH SENS 22.2 .
• SSER: 10.0
'
,3 ,
S.P .150' .
CFM 1000 .-'
I.
1
( L J
I
tri
I
2"0-
1 4"0
J
I s • •
I snre rim •—• toompt
re
4
/'
• WIPP
HVAC FLOOR PLAN
SCALE:1 /4" -.1 0"
I I
I 1
1 I
I I
I I
o e6
•
No drawn doll be ando to ties sop•
et work without prior approval of
Waal'
NOTE: Ravidommill require a new pion submittal
and may kclude addRional plan review few.
de
LI
REVIEWED FOR
CODE COtAPLIOACE
APPROV
SEPARATE PERMIT
REQUIRED FOR:
O Methiks'
• Electrical
D Pfl'Q
O Gas PlOng
City Of
BUILDING DIVISION
-""" 7dr7 ...7 . Jr • 4.1*.e,:rs.rs• •
4,
A
— 4
Paw* No.
Ran fekiew approval j subject to errors c and minion&
frolokel of onsbuction doaiments does not auttiOrils_
VI! **Ion of any dooptod code cr ordhance a*
APPleved Read Copy arid conditions Is acknoMedollk
1)/
at
ign111041
M04-185
PERMIT CENTER
RECEIVED
CITY OF TUKWILA
0 C T 2 2 2884
0
IL
;HEE? NUMMI
-J
CC
0
0
LL
>-
z
O o
O 0
z (5)
( .0
z .
O �Zcc
,- cc
t --- Y
z r
Do
w
<
M1 .0
L100 fra4111100101 Ps,
4
I
•
'• .•••■•■••■••41. ••■••••••■• : •••••■•■•.■ .1;4. 110.7.1a0116111Pairgeii4t. AMUlarki $1••*:
•
i
0
AMBIENT CONTROL COMPANY
1411 R. ST. NW
AUBURN, WA. 98001
(253) 876 -9933
TITLE •
SITE PLAN
4r -11 i fr
FOR •
SOUTHCENTER SOUTH
18340 OLYMPIC AVE S.
TUKWILA, WA. 98188
SCALE
J NUMSER
ORAVIINGI M
DA*
Owen
CHEPOID av
•
r
NO. DATE BY REVISION .