Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M04-188 - BLACK BOX
Parcel No.: Address: Suite No: Tenant: Name: BLACK BOX Address: 200 ANDOVER K E, TUKWILA WA Owner: Name: ABBOTT JAMES W Address: C/O IRONWOOD INVESTMENTS, 1501 N 200 ST Contact Person: Name: ERIN EATON Address: 1221 2 AV N, KENT WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N, KENT, WA Contractor License No: HERMACLOO5BJ DESCRIPTION OF WORK: ADDITION OF A NEW 3 TON GAS HEAT A/C UNIT AND IT'S ASSOCIATED DUCTWORK AND GRILLES TO SERVE A NEW TRAINING ROOM AND A NEW 1.5 TON SPLIT SYSTEM A/C UNIT FOR A NEW SERVER ROOM. Value of Mechanical: $16,170.00 Fees Collected: $380.25 Type of Fire Protection: International Mechanical Code Edition: 2003 Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC- Permit City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.wa.us 0223100099 200 ANDOVER PK E TUKW MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M04 -188 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 575 -9700 Phone: 206 - 575 -9700 Expiration Date :08 /25/2006 Steven M. Mullet, Mayor Steve Lancaster, Director M04 -188 11/19/2004 05/18/2005 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 4 Thermostat 2 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 11 -19 -2004 Permit Center Authorized Signature: The granting of this regulating constr Signature: City () Tukwila doc: IMC- Permit Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukivila.wa.us Date: Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M04 -188 Issue Date: 11/19/2004 Permit Expires On: 05/18/2005 afr I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. it does n•t presume to give authority to violate or cancel the provisions of any other state or local laws ion or the -- • • f work. I am authorized to sign and obtain this mechanical permit. Date: Print Name: C 'tea° SF1Z)1 V This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M04 -188 Printed: 11 -19 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223100099 Address: 200 ANDOVER PK E TUKW Suite No: Tenant: BLACK BOX 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: M04 -188 Status: ISSUED Applied Date: 10/22/2004 Issue Date: 11/19/2004 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M04 -188 Printed: 11 -19 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. doc: Conditions M04 -188 of law and ordinances other work or local laws Printed: 11 -19 -2004 'CONTACT PERSON Company Name: Mailing Address CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Name: 1 " ►`-' n A `� c Mailing Address: I50( ' Y 4! + 7,Q)/i + Company Name: � P OL P ?. 4 - r∎. 5 Contact Person: i c "i b b . E -Mail Address: m •C (ibbatS i ntoiol2_cAY Q1 t 00 Contact Person: DA PC.-- lk /N1 'appiicationa'permit application (7 -2004) W TUKWIIA W Building Permit No. WI-211g Mechanical Permit No. /C/i. -G0) Public Works Permit No. Project No. %Applicationsand;plansmust becomplete;in.orderto be ted.for: lan review.; Applications will not a accepted through th mail or b ax. * *Please Print ** Company Name: I Z i~ 0.0 O Mailing Address; 1 2-N.) F v- E -Mail Address; (ineh Iren M t ocm Pace 1 For o ce use on! SITE LOCATION 0.-WreR C W ing Co Assessor's Tax No.: 22-31000Cr 1 ZOO FItZpu£.f� �FTfL1[ '1 Site Address; IJll ALIA- , t(..1� �}S i� Suite Number: Tenant Name: U_ LYX, New Tenant: ant:: Property Owners Name: t 3 � h&e.,i Jtco / " Qc . , ,, L1'- Mailing Address: 1501 KY-17-111 t mil' 1O1t W DJ ILA City State Floor: ❑ Yes Ar..No q8/3 Zip Day Telephone: LC O '553 , r1l� rte_ wt �SY33 City State Zip E -Mail Address: Fax Number: NERAL' CONTRACTOR' : INFORMATION (Mechanical Contractor information on back page) - Sep,, (ATf g Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address; Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record State ARCHITECT OF RECORD: All plans must be wet stamped' by Architect of Record k . .i• / -` - d► it - •_1 . L" .1. S ' rl_ State Zip ty Day Telephone: Fax Number: City State Zip Day Telephone: 2.-00 37$ '7t'O Fax Number: 2 o 51:5 - /SCO Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser /()Z.i L& Thermostat ( 3 -15 HP /500,000 BTU 15 -30 HP /1,000,000 BTU Floor Furnace Ventilation Fan Suspended/WalUFloor Mounted Heater . Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System 2 Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: tIl:�.f r tf %..)& L) hoe.. () L7 `&" Mailing Address; 1224 ? 4 J lb NJ City Contact Person: Day Telephone: E -Mail Address; L wtt- 1V 'n Contractor Registration Number: IeM' )I4 ,Lt O Fax Number: State Zip 760 . 0o � �- 51 -0co at �h Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented permit issuance ** Valuation of Project (contractor's bid price): $ ' / ( f O oG Scope of Work (please provide detailed information) Addition of a new 3 ton gas heat AC unit and It' 'associated ductwork and grilles to serve a new training room and a new 1.5 ton split system AC unit for a new server room. Use; Residential: New ❑ Replacement ❑ Commercial: New ....X Replacement ❑ Fuel Type: Electric ❑ Gas ....k Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: Mailing Address; 1Z-- I Zt' N V \appliations'pemtit application (7.2004) Pace 4 Date: /Z/Z-IAYI Day Telephone: 2��0 575- -49700 <«' 1i 1+t 9 :CUB' City State zip Date Application Accepted: 1t - —0 Date Application Expires: ZZ c( Staff Initials: i RECEIPT w 2 Parcel No.: 0223100099 Permit Number: M04-188 . _ m ' oi Address: 200 ANDOVER PK E TUKW Status: APPROVED 1 , 0 0 .. Suite No: Applied Date: 10/22/2004 w LL1; Applicant: BLACK BOX Issue Date: fJ 10 u_ ui Oi g 3i Receipt No R04-01561 Payment Amount: 286.20 U) D '— Cr Initials: SKS Payment Date: 11/19/2004 11:43 AM LU; User ID: 1165 Balance: $0.00 f z Payee: City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 HERMANSON CO. LLP TRANSACTION LIST: Type Method Description Payment Check 1449 • ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES doc: Receipt 000/322.100 286.20 • 111', n; D (-) COI :0 It Amount IL 286.20 C.) — I= • 0 Z Total: 286.20 7131 11/22 9716 TOTAL. 2E16.20 Printed: 1 1-1 9-2004 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0223100099 200 ANDOVER PK E TUKW BLACK BOX R04 -01447 BLH ADMIN HERMANSON CO LLP TRANSACTION LIST: Type Method Description doc: Receipt Payment Check 1429 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES RECEIPT Account Code 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 64.05 Payment Date: 10/22/2004 03:48 PM Balance: $286.20 Amount 64.05 Current Pmts 64.05 Total: 64.05 M04 -188 PENDING 10/22/2004 6312 1 0/26 9716 Turk 64.05 Printed: 10 -22 -2004 Project--n 1 ( 11.10 WI C_V-- 1)0 )e Type of Inspection: r ew, I Address: A 200 Date Called: Special Instructions: Date Wanted: a.m. p .m. Requester: Phone No: 1 0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 ( 'aoa ,P ttMIT NO. 206)431-3670 ta Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Cool ei \L- 4-6 ■ ntA $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pr6'e ck Type of Inspe n ax Addr ss:� , a () A=SE- Date Called: 4�`l5'ro�f Date Wanted: to I � (O ( rLj' � a.m. Special Ins uctions: Requester: ` Ph e N o: �� 5� _7j Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: �� .�►n Q _girrks .. A Al %Jr spe Receipt o.: Date: - 14.--0 7.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: SB { ■ ne w. .0. Co ., W ~ . J u. w o o LL Qa N M : v . W. Z F uj o co, D I- 111 w F ( 2, IL Z U N '.. O Z Project:, " / A-.:. -C' -GEC Type of Ins lion: .! ' ion: Address: eA : ''�rA`r/ -e-r "X...! L. D at e Called: /_2 / t / _o y Special Instructions: / _ �s+j, rC»LP ��CT- l�cr�'`' �: z � /C • Date Wanted: ,, a.m. /2 4 ( ,,_ .m. Requester: , ( C Phone 6 ' Z: 4 UQ INSPECTION RECORD Retain a copy with per. it INSPECTION NO. / OF TUKWILA BUILDING I ON 0 6300 Southcenter Blvd., #100, Tukwila, WA 98188 /0 El Approved per applicable codes. 44 Corrections required prior to approval. COMMENTS: 0 L- 4 „sr., Date: .00 REINSPECTION FEE R • QUIRI<D. Prior d at 6300 Southcenter Blvd., Suite 100. C Z -• 1 —Oy o inspection, fee must be I to sched}Ile reinspection. Receipt No.: 'Date: W . oct w O, Cw w o g Q . Z w V0 :O N' o1-1 = W r - 0' iW Z z Project: B)- t o/C • Type of Inspection; Pe- t isvykl..1 4 ( o Ki+iJ \ Address: OCR Pt 9i� =i) v- 1� - Date Calle 1 - r1—o-/ Special Instructions: ate Wanted: 12 ..- 1 -- Q ll a.m. p.m. Requester: ale K--- Phone No: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER (206)431 -3670 Corrections required prior to approval. COMMENTS: Date: 2. —rS — REINSPECTION FEE RE UIRED. Prior t inspection, fee must be at 6300 Southcenter Blvd., uite 100. Call o schedule reinspection. 'Receipt No.: 'Date: Project: f l✓4-ef oO Type of Inspection: • S (AO lLf 5ti wtredLA.1A Date Called: l 2 -V-1- o Y Address: ?aft A --hrd 0r9 P K. Special Instructions: Date Wanted: c,f 1'2 l S O ! a.m. p.m. Requester: A. ; e 6 Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 /Yl og —I 68 PERMIT O (206)431 -3670 Approved per applicable codes. DI Corrections required prior to approval. COMMENTS: i lns ect Date: c -^-)C —c.., 12- --1 j - 0 EIS REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pr ect: , . : • 1 .51 Ac 11 -- ( o,c . ` - Type of inspection: - • ; wt rAh 71► Address: g,o n -6� � Dat: ' Date Called: ,,.4. , , Special Instructions: Date,Wanted: / / / a.q / 'i a.m. p.m. Requester: /' I 4-- Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 Tukwila,-WA 98188 Approved per applicable codes. - y 3 (206)431 -3670 Corrections required prior to approval. COMMENTS: / (5) h W ' ovf2 --% pprad / ^ / o r 6 ; Chet h ' J-t' 2//U/T /4--7` r' /N-vl. 1j Date: / / / c5 .00 REINSPECTION FEE EQUIREVPrior to inspection, fee must be aid at 6300 Southcenter BI ., Suite 00. Call to schedule reinspection. Receipt No.: 'Date: Proecti L Z ox, 15 L « Type of Ins o: / 77 Ad ess: Date Called: / Il Li 0 ` . / S ecial Instructions: Date Wanted: / tem Requester: La gho No: ( 0 r 14 „ . . INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 pproved per applicable codes. Corrections required prior to approval. COMMEN i.)Lic f*Civc, nspe •: 44 / ) Date: / .00 REINSPECTION FE REQUIRED. Pr i to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r eceipt No.: JDate: 2 •6)43 -3670 Prt: T fnsptn: P rr r Addres : , 12 PIZ-- Date Called: H h ? ' Special Ins ructio s: Date anted: 1 t a.m. / p.m. Requester: ! P on j ) (v / —i2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (206)431 -3670 P Appro Led per applicable codes. ❑ Corrections required prior to approval. COMMENTS: I I specto : a $4 4 i REINSPECTION FEE REQUIRED. Prior to (spection, fee must b p • t 6300 Southcenter Blvd., Suite 100. Call t schedule reinspection. I Rece . No.: 'Date: ( Date: /l / 23 Proj lL ,� .. Type of Inspection: 42A4.. � , -- ) - 0„1 Address: IOCD NCO JV tZ- Pi4. Date Called: f I , J - z - z. l 0 Y Special Instructions: Date Wanted: a.m. 1 2 f eet p.m. Requester: )2_, IL Php ne No: . INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: uAN I 11 ( U ( ' I ;a -.bet tor: Date: Approved per applicable codes. Corrections required prior to approval. El 7.00 REINSPECTION "FEE REQUIRED. Prio /to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: P t 4(k (Ay 'Ty of Inspec ion:, }G(.1 ► ' . \ Ad Date ailed: r +' • , 2 A 0 /jo Special I / - Date Wanted: y -a Requester: s 4 p Ph o: ■ t, pproved per applicable codes. Corrections required prior to approval. COMMENTS: 1 2 -C/C .4 = A. - -1 - D .;� e r5 c..A-; (2._) Do,..h0 b 4-- u v,t, a 2 VV ti `. t, INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY `OF TUKWILA BUILDING DIVISION �•� 4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 r, 2966)4131 -36 ' my REINSPECTION FEE REQUIRED. Pri9f to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. all to schedule reinspection. (Receipt No.: 'Date: W: 00: to o; wi air .0u.: g J. • U 0. O N! :0 UJ W F U ! I ii z. U = i Z F-. sis ENW ENGINEERS NORTHWEST, INC., P.S. STRUCTURAL ENGINEERS 6869 WooplAWN An. N. Swum, WA 98115 (286) 525-7S60 FAX (206) 522-4698 FAX TRANSMISSION COVER SHEET To: SGA CORP. Arm Linda McMaster RE: Mech. Units —13LA.C1c, BOX T.I. FAX: (206) 533-2196 DATE: October 21, 2004 PROJECT: 04000093 NUMBER OF PAGESWCOVER SHEET INCLUDED) — ORIGNAL(S) TO FOLLOW: F171/ Dear Linda McMaster, I have attached structural drawings (S1, S2, 84 S3). lif Neid CAD Technician From: 208 522 8698 Page: 1/4 Date: 10/21/2004 12:08:28 PM REVIEWED FOR CODE COMPLIANCE PoRPVED NOV 1 7 2004 C1i Of Tukwila BUILDING DIVISION IF YOU DID NOT RECEIVE ALL PAGES INDICATED ABOVE, PLEASE CALL (206) E-mail: breidOenwseattle.com 61tati\ CITY ILA AUG 2 2003 PERM CE ER 973-5416 ctrAteetvED OCT 2 2 2004 IT C IV/468 AIINIMMIIV BLACK BOX Til. 200 Andover Park East, Tukwila, WA c. -...- i 'Cilr, ; , ..,)- 4 A 1.1 - ,t_ /6 14 o ‘"/ONAL 011. OWN: BR i......... ENG'D: R. RAICHLE MECHANICAL UNIT LOCATION - PLAN IN.T.8J JOB NO: 04000093 ........ DATE: 10/20/04 mlem. - ..■ .... ENGINEERS NORTHWEST, INC. 6869 WOODLAWN AVE. N.E. SEArLE, WASHINGTON 98115 1111wwwli■smilMIMMY SHEET. 1 OF 3 Si ■ WPM InsAl 4 A From: 206 522 6698 Page: 2/4 Date: 10/21/2004 12:08:28 PM PLAN N.T.S. EXIST. TRUSSES 8' —O "o/c From: 206 522 6698 Page: 3/4 Date: 10/21/2004 12:08:29 PM r LOCATE NEAR GRID ©- 1Q 4 x 4 0 CURB w/ SIMPSON HU HGRS. ADD 4 x 4 0 EA. EDGE OF UNIT w/ SIMPSON HU HGRS. OR BEAR ON EXIST. 4 x 4 CENTER UNIT BTWN TRUSSES NEW MECHANICAL UNIT METAL CURB BY MFR SCREW LAG SCREW TO 4 x 6 w/ 1 "0 x 3" LAGS (2 EA. SIDE) STIFFENERS 0 24 "o /c ECTION M1 MECHANICAL UNIT SUPPORT - 1' -0" BLACK BOX T.I. 200 Andover Park East, Tukwila, WA MECHANICAL UNIT - SECTION .1 ENGINEERS NORTHWEST, INC. 6869 WOODLAWN AVE. N.E. SEATTLE, WASHINGTON 981 15 DWN: BR ENG'D: R. RAICHLE JOB NO: 04000093 DATE: 10/20/04 SHEET: 2 OF 3 S2 BLACK BOX T.I. 200 Andover Park East, Tukwila, WA •1 • ` � � 4 t4 ma �* ' ,1 Jf'' " DWN: B _ ■ JNG'0: R. RA1CHLE MECHANICAL UNIT - SECTION .2 JOB NO: 04000093 DATE 10/20 /04 jJ_ d pn, t SHEET: 3 OF 3 S 3 ENGINEERS NORTHWEST, INC. 8869 WOODLAWN AVE. N.E. SEATTLE, WASHINGTON 98116 EMS 0/29/1)8 f - M TECH. UNIT & CURB 550# MAX. CENTER C.G. OVER GLB rii•Ar4 I ill ee.. ri /,/ UPI I /41 OMW r //1 MIM rill ninny- r //i LAG CURB 4 x6 w/ „, x 3" 2 4 "0% From: 208 522 6698 Page: 4/4 Date: 10/21/2004 12:08:29 PM NEW 4x8 0 EA END w/ HU48 HANGER LOCATE APPROX. 12' —O" WEST OF GRID°2 SECTION 82 MECHANICAL UNIT SUPPORT Tag: All dimensions are in inches/millimeters. EVAPORATOR SECTION ACCESS PANEL 1 ALTEMIATE CONDENSATE DRAIN CONNECTION X4 • 14 !VT Ca. HOLE . 23 Mr INMAN ' or 11/111441 tO IT IP2 NPT OAS CONNECTION PILE COPY Permlit rOn- Sir la VC 244 IME — CONTROL AND COMPRESSOR ACCESS PANEL ■••■•■••■••■•••■•• 3 7bn Standard Eilkiancy —High Heat //— TOP PANEL 4 0111M. •-• sans. 141 PAN 'sr 154154 a 1/4 1124114 EVAPORATOR SECTION ACCESS PANEL 41/4 ALTERNATE CONDEliSAIALLW4 CONNECTion 1M • 14 NPT DiA.NuLs CONDENSER FAN 1/4 115154 3 Ton CONDENSER UNIT CONTROL VANE Tar OW DIA. HOLE SERVICE 014105 Pair 1 ST MUM) DIA. ROL UNIT POWER WIRE 1 3/3T(214101)DI& HOLE RtraftWETY fl6fladjunl CODE COMPLIANCE APPROVED NOV 1 7 2004 Cit Or tukwild BUILDING DIVIS/ON / ,. TOP PANEL 10T3IM 1T75141 201 154 U2 NPT OAS COVECTION .555 142 111 SW 044154 CONTROL AND COMPRESSOR ACCESS PANEL 141 11 ", 71W 44 tNT Standard Efficiency 3Ton Packaged Gas/Electric Convertible YSCO36A CONDENSER FAN Ss Ile sat NA1 75 ccoactaim COL SWAGE MODE PORT ACIXSS 11W WM) Ca HELL UNIT POWER WIRE I MT (211111) Ca 140LE __RECEIVED cm. OF TUKW/LA ocT 2 2 2004 PERMIT CENTER Table 1 — GaneM, Data CoolingPetfonnance' Gross Cooling Capacity 37,400 37,400 SEER' 10.5 10.7 Nominal CFM / ARI Rated CFM 1200/1200 1200/1200 ARI Net Cooling Capacity 38.000 38,000 System Power (KIM 3.91 3.79 Heating Perfomtanee' Heating Models Low Medium High Low Medium High Heating Input (Btu) 60.000 80.000 120,000 60.000 80,000 120,000 Heating Output (Btu) 47,000 63,000 95,000 48,000 64,000 96,000 AFUE %' 80 BO 80 81 81 81 Steady State Efficiency ( %) 80 80 80 81 81 81 No. Burners 2 2 3 2 2 3 No. Stages 1 1 1 1 1 1 Gas Supply Line Pressure Natural (minimum/maximum) 4.5/14.0 4.5/14.0 LP (minimum/maximum) 10.0/14.0 10.0/14.0 Gas Connection Pipe Size fn.) 1/2 1/2 1/2 1/2 1/2 12 Compressor No/Type 1/Hermetic 1/Hermetic Outdoor Sound Riding (dBI' 83 83 Outdoor Co o - Type Lanced Lanced Tube Size (in.) OD .3125 .3125 Face Area (sq ft) 7.19 7.19 Rows/FPI 2/17 2/17 Indoor Coil - Type Lanced Lanced Tube Sae (in.) .3125 .3125 Face Area (sq ft) 5.67 5.67 Rows/FPI 2/16 2/16 Refrigerant Control Short Orifice Short Orifice Drain Connection No/Size (n.) 1/ii NPT 1Hf NPT Outdoor Fan -Type Propeller Propeller No. Used/Diameter fin.) 1/22 1/22 Drive Type/No. Speeds Direct/1 Direct/1 CFM 2550 2550 No. Motors/HP 1/.20 1/.20 Motor RPM 1075 1075 Direct Drive Indoor Fan - Type FC Centrifugal FC Centrifugal No. Used/Diameter (in.) 1/10 X 10 1/10X 10 Drive Type/No. Speeds Direct/2 Direct/2 No. Motors 1 1 Motor HP ( Standard/Oversized) .33/.50 .33/.50 Motor RPM ( Standard/Oversized) 950/1100' 930/1100' Motor Frame Size ( StandardLOvers 48/48 48/48 r an - ype — elm uga No. Used/Diameter (in.) — 1/11 X 11 Drive Type/No. Speeds — BelWariabte Sheave No. Motors — 1 Motor HP ( Standard/Oversized) — 1.00/— Motor RPM (Standard/Oversized) — 1750 — Motor Frame Size ( Standard/Oversized) — 56L. Attars - Type Throwaway Throwaway Furnished? Yes Yes (No.) Size Recommended (2)20X 25 X1 (2) 20 X 25 X le Refrigerant Charge (Lbs of R-22)' 3.8 3.8 3Ton Convertible Units YSCO3841 YSCO3643. A4,AW Notes: 1. Cooling Perfonnance rated% 95 F ambient, 60 F entering dry bulb,67 F entering wet bub. Gross capacity doesnot Include the elf act of fan motor heat. ARI capacity is net and includes the el fact of Ian motor heat. Units are suitable for operation to *20% of nominal cfm. Units are certified in accordance with the Unitary AlrrCondltlonerEquipment certification program, which 13 based on ARI Standard 210/240. 2 EER and/or SEER are rated at ARI conditions end in accordance with DOE test procedures. a Integrated Part Load Value is %%din accordancewith Standard 210/240 or 360. Units are rated at 90' F ambient, F entering dry bulb, and 67' F entering wet bulb at ARI rated cfm. 4. Heating Performance limit sittings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. 6 AFUE is rated in accordance with DOE test procedures. H Outdoor Sound Rating shown Is tested In accordance with ARI Standard 270. For additional information, reference appropriate table. 7. Refrigerant charge ban approximate value. For a more precise value, see unit nameplate and service instructions. a 20x25f Hier on medium and low heat models. 20330 filter on high heat models 9. Motor RPM shown blow speed. Highspeed RPM is 1060/1145. OEM Mow Bulb 61 67 (F) P131 101117 73 1913R 61 REFr9C 67 73 (s3771C 81 67 73 1 NEFI mr 81 87 73 021:1 pur 1G9T IVI3F1 M 75 34.6 29.0 38.6 22.3 40.6 14.7 31.2 2/3 36.6 21.1 39.5 13.8 28.2 25.6 33.4 19.6 37.8 12.9 25.1 24.1 29.8 18.2 35.5 11.9 80 35.6 35.0 38.8 27,3 41.0 20.2 32.6 32.6 36.8 26.6 39.8 19.5 30.0 30.0 33.5 25.2 38.0 18.5 27.3 27.3 29.9 23.5 35.6 17.5 108D 85 37.6 37.6 39,2 32.5 41.5 24.7 35.6 35,6 37.2 32.2 40.1 24.2 32.8 32.8 34.2 31.0 38.2 23.8 30.1 30.1 30.7 29.3 35.8 23.0 90 39.3 393 39.7 376 42.0 29.2 378 378 379 376 40.4 29.1 35.7 35.7 35.7 35.7 38.5 28.9 33.0 33.0 32.9 32.9 36.0 28.4 75 35.6 30.9 39.0 22.8 40.9 14.9 32.2 29.2 37.3 22.1 39.8 14.1 29.0 27.5 34.3 20.7 38.2 13.1 25.9 25.9 30.4 19.0 36.0 12.1 80 36.7 36.7 39.3 28.4 41.4 20.6 34.3 34,3 37.4 28.1 40.2 20.3 31.4 31.4 34.5 26.9 38.4 19.3 28.8 28.6 30.7 25.2 36.1 18.3 1200 8 5 3 8 . 7 3 8 . 7 3 9 . 7 3 3 . 9 4 1 . 9 2 5 . 3 3 7 . 0 3 7 . 0 3 7 . 9 3 4 . 0 4 0 . 5 2 5 . 0 3 4 . 5 3 4 . 5 3 5 . 3 33.2 38.7 24.8 31.5 31.5 31.7 31.8 36.3 24.2 90 40.2 40.2 40.4 39.2 42.3 30.1 38.8 38.8 38.8 38.8 40.9 30.2 371 37.1 37.0 37.0 39.1 30.3 34.6 34.6 34.6 34.6 38.6 30.0 75 36.4 32.6 39.4 23.5 41.1 15.1 33.2 31.0 37.7 23.0 40.1 14.3 29.8 29.3 34.9 21.8 38.5 13.4 26.8 26.8 30.9 20.0 36.3 12.4 1320 130 85 37.7 39.4 37.7 39.4 39.7 40.2 29.4 36.2 41.6 42.1 20.9 25.9 35.7 37.9 35.7 37.9 37.9 38.5 29.3 35.6 40.4 40.8 21.2 25.7 32.7 35.9 32.7 35.9 35.2 36.2 28.5 35.3 38.7 39.1 19.9 25.7 29.8 32.9 29.8 32.9 31.4 32.9 26.8 32.9 36.5 36.7 19.0 25.3 90 40.8 40.8 40.9 40.5 42.6 30.8 39.7 39,7 39.6 39.6 412 31.2 3ao 38.0 38.0 38.0 39.5 31.6 35.9 35.9 35.9 35.9 371 31.5 75 37.0 34.1 39.7 24.0 41.3 15.3 34.1 32.8 38.0 23.7 40.3 14.5 30.6 30.8 35.5 22.7 38.7 13.8 27.7 27.7 31.4 21.0 38.6 12.6 80 38.4 38.4 40.0 30.3 41.8 21,2 36.7 36.7 38.3 30.6 40.13 21.0 33.9 33.9 35.8 30.0 39.0 20.4 30.8 30.8 32.0 28.4 38.8 19.7 1440 85 40.0 40.0 40.8 36.3 42.4 28.4 38.7 38.7 39.0 37.0 41.2 26.7 38.8 36.8 38.8 38.8 39.4 26.6 34.2 34.2 34.2 34.2 37.0 26A 90 41.4 41.4 41.4 41.4 42.9 316 40.3 40.3 40.3 40.3 41.5 32.1 38.7 38.7 38.7 38.7 39.9 32.7 36.7 38.7 38.7 36.7 376 33.0 Mb 2 Gross Cooling Capacities (MBH) 3 Ton Sing le/77wse Phase YSCO3641, 44 A4, AW Enter. Dtv 85 Ambient Temperature (F) as 105 Entering Wet Bulb (F) 3 115 No tes: 1. N capacities shown are gross and have not considered Indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat I ormula, tel er to appropriate airflow table notes, SASH • Total Gross Capacity a SHC • Sensible Haat Capacity lhble 3- Direct Drlwe Evaporator Fin Performance 3 Ton YSCO M - Low and Medium Heat External Static Pressure (Inches of Water) & Motor Power (Bhpl' Standard Motor Oversized Motor' High Speed Low Speed High Speed LowSpeed Unit Tons Model No. GM ESP EI P E P BHP DP BI-P ESa 1}P 960 0.81 0.36 0.61 0.28 0.96 0.39 0189 0.35 1020 0.77 0.37 0.57 0.28 0.94 0.41 0.86 0.47 1080 0.73 0.38 0.50 0.29 0.91 0.43 0.82 0.39 1140 0.69 0.39 0.42 0.29 0.68 0.44 0.77 0.40 3 YS0336A'•1_,M 1200 0.66 0.40 0.34 0.30 0.84 0.45 0.74 0.41 Horizontal Airflow 1260 0.60 0.41 0.28 0.30 0.80 0.48 0.70 0.42 1320 0.55 0.42 0.14 0.31 0.75 0.48 0.65 0.44 1380 0.49 0.42 0.05 0.31 0.70 0.49 0.59 0.45 1440 0.44 0.43 - - 0.64 0.52 0.54 0.48 960 0.81 0.36 0.61 0.28 0.96 0.39 0.89 0.35 1020 0.77 0.37 0.57 0.28 0.94 0.41 0.86 0.47 1080 0.73 0.38 0.50 0.29 0.91 0.43 0.82 0.39 1140 0.69 0.39 0.42 0.29 0.88 0.44 0.77 0.40 3 YSCO36A••L,M 1200 0.66 0.40 0.34 0.30 0.84 0.45 0.74 0.41 DownflowAirflow 1260 0.60 0.41 0.26 0.30 0.80 0.46 0.70 0.42 1320 0.55 0.42 0.14 0.31 0.75 0.48 0.65 0.44 1380 0.49 0.42 0.05 0.31 0.70 0.49 0.59 0.45 1440 0.44 0.43 - - 0.64 0.52 0.54 0.48 Fan motor heat fMBHi 4.39x Fan Bhp. Factory suppled motors, In commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged condtons. Using the full horsepower range of our fan motors as shown in our tabular data will not result In nuisance tripping or premature motor failure. Our product's warranty will not be affected. Notes: 1. Data indudes presaure drop due to wet coil and filters. Table 4- Drfect Drive Evaporator Fan Performance 3 Ton ' SCO364 - High Heat External Static Pressure (Inches of Water) & Motor Power (Bhpl' Standard Motor Oversized Motor High Speed Low Speed High Speed LowSpoed Unit Tons Model No. OEM ESP EH ESP 8FP ESP B-P ESP B P 960 0.76 0.36 0.56 0.28 0.91 0.39 0.84 0.35 1020 0.72 0.37 0.52 0.28 0.89 0.41 0.81 0.47 1080 0.68 0.38 0.45 0.29 0.86 0.43 0.77 0.39 1140 0.64 0.39 0.37 0.29 0.83 0.44 0.72 0.40 3 YSCO36A••H 1200 0.61 0.40 0.29 0.30 0.79 0.45 0.69 0.41 Horizontal Airflow 1260 0.55 0.41 0.21 0.30 0.75 0.46 0.65 0.42 1320 0.50 0.42 0.09 0.31 0.70 0.48 0.60 0.44 1380 0.44 0.42 0.00 0.31 0.65 0.49 0.54 0.45 1440 0.39 0.43 - - 0.59 0.52 0.49 0.48 960 0.76 0.36 0.56 0.28 0.91 0.39 0.84 0.35 1020 0.72 0.37 0.52 0.28 0.89 0.41 0.81 0.47 1080 0.68 0.38 0.45 0.29 0.86 0.43 0.77 0.39 1140 0.64 0.39 0.37 0.29 0.83 0.44 0.72 0.40 3 YSCO36A "H 1200 0.61 0.40 0.29 0.30 0.79 0.45 0.69 0.41 DowntowAirflow 1260 0.55 0.41 0.21 0.30 0.75 0.46 0.65 0.42 1320 0.50 0.42 0.09 0.31 0.70 0.48 0.60 0.44 1380 0.44 0.42 0.00 0.31 0.65 0.49 0.54 0.45 1440 039 0.43 - - 0.59 0.52 0.49 0.48 Fan motor heat IMBH) - 4.39 x Fan Bhp. Factory supplied motors, In commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown In our tabular data will not result In nuisance tripping or premature motor failure. Our product's warranty will not be affected. Notes: 1, Data Includes pressure drop due to wet coil and titers. Table PD55 - Deft Dlly. Evaporator Fan Perfiomranoe - 3 Ton - !'SCO36A3A4AWL. M - Low and Medium Heat - DownfowAHbw External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 CAN RPM EH' FPM Blf fPIN EH' RPM 9 RPM SIP R1 'M EH' ,. , . EHP 11N 81P Rile BP RPM E#P 141P Standard Motor & Field Supplied ed Low Stade Drive (1) 980 - - 570 0.14 634 0.18 6E0 0.22 741 0.27 1080 537 0.14 806 0.18 689 0.23 724 0.27 T,8 0.32 1200 581 0.18 646 0.22 705 0.27 759 0.33. 801 0.38 1320 627 0.23 686 0,28 742 0.33 795 0.39 842 0.44 1440 673 0.29 728 0.34 1 780 0.39 831 0.45 818 0.52 For Standard Evaporator Fan Speed (RPM), reference approprIate table. Notes: Oats Includes pressure drop due to standard filters and wet coils. Fan Motor Heat )MOH) 2.829 x Fan 8HP+.4024. 1, FieldSupp %ed Fan Sheave AK89requlred. Field Supplied 8e9 may benecessary, 2. Field Suppled Fen Sheave AK4l required. Field Supplied Belt may benecessary. 1- PStandardMotor &Field Suppled Low M od ° (Moo (1) 960 552 0.13 631 0.17 699 0.22 1080 598 0.17 675 0.22 739 0.27 1200 845 0.22 720 0.28 1 781 0.33 1320 693 0.28 786 0.34 825 0.40 1440 743 0.35 811 0.42 871 0.49 For Standard Evaporator Fan Speed (RPM), ref erenceapprapdatelable. Notes: Data includes pressure drop due to standard tigers and wet coils. Fan Motor Hest (M EMI .2.829 Fan BHPa.4024. 1. FieldSuppliedFan Sheave AK69required, Field Supplied Beg maybe neoessery. 2. FieldSuppile dFanSheaveAK4lrequired .FeldSuppliedBehmaybenecessary. Table PD-6 - Continued 791 0.31 836 0.36 879 0.41 972 0.48 981 0.52 819 0.38 864 0.41 906 0.47 946 0.52 985 0.58 851 0.42 894 0.48 935 0.53 973 0.59 1011 0.65 895 0.50 927 0.55 988 0.61 1003 0.67 1040 0.73 921 0.58 900 0.64 998 0.69 1034 0.76 1070 0.82 Factory supplied motors, In commercialequipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be alfected. External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP LIP Standard Motor & Drive 960 1000 0.67 1037 0.83 1072 0.69 1106 0.76 I 1139 0.81 1080 1022 0.64 1058 0.70 1093 0.78 1 1127 0.82 1161 0.89 1200 1047 0.71 1083 0.77 1117 0.83 J 1150 0.90 1183 0.97 1320 1076 0.79 1108 0.85 1 1141 0.92 1174 0.99 1208 1.06 1440 1104 0.88 1137 0.95 1170 1.02 1201 1.09 1231 1.16 Tale PDT Deft Drive Evaporator Fan Performance - 3 Ton - VSCO36A3A4AWL. M - Low and Medium Heat - HorizontalAkfow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 CAN 8714 BIP Rile BP Rile MP R'M Bf R' 4 BP Rile Bf FF A Bf' FFM BFP RFM BFP I1RN Bf 759 0.27 811 0.33 858 0.38 902 0.44 943 0.49 980 0.54 1017 0.60 798 0.33 850 0.38 898 0.44 941 0.50 902 0.57 1020 0.63 1056 0.69 837 0.39 889 0.45 937 0.51 981 0.58 1021 0.65 1059 0.72 1095 0.79 879 0.47 929 0.53 976 0.60 1020 0.67 1081 0.74 1099 0.81 1 1135 0.89 922 0.55 970 0.62 1016 0.69 1059 0.77 1099 0.84 1138 0.92 1174 1.00 1-11Pt Isexhrd Motor & Reid Supplied High Static Drive (2) Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty wit not be affected. Table PD-6 - Continued 1a1P Standard Motor & Mho 1-HP Standard Motor & Reid Supplied High Static Drive (2) 1-HP Standard Motor & Drive External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1-FP Standard Motor & 960 1052 0.65 1088 0.71 I 1120 0.77 1152 0.83 1185 0.90 1080 1090 0.75 1 1123 0.81 1154 0.87 1185 0.93 1215 0.99 1200 1130 0.86 1182 0.92 1193 0.99 1224 1.05 1253 1.12 1320 1169 0.96 1203 1.04 1233 1.12 1263 1.19 1292 1.26 1440 1208 1.08 1241 1.18 1273 1.25 1303 1.33 1332 1.41 1-HP Standard Motor & Field Supplied High Static Drive (2) 5 iu DU' 0(3! u)0 NW; W O, g J u- a: ZOt 111 uj 0 fD -, OH la id Ui 1t, Z w Z Table 7 - Belt dive Evaporator Fan Performance - 3 Ton - YSG10.96A3,A4AW•H - High Heat - Downftow Airflow .10 CAN FPIN BP 960 603 0.11 1080 648 0,15 1200 593 0.19 1320 640 0.24 1440 688 0.31 .20 .30 FPM BFP FPM BP 1.HP Standard Motor & Field Supplied Low Patio Delve(1) 578 0.15 641 0.19 616 0.19 678 0.23 657 0.23 718 0.28 696 0.29 I 754 0.34 742 0.35 794 0.41 For Standard Evaporator Fan Speed (RPM), reference appropriate table. Notes: Data Includes pressure drop due to standard filters and wet coils. Fan Motor Hest (MBH) • 2.829 n Fan BHP +.4024. 1. Field Supplied Fan Sheave AK09requked .FleldSuppied Belt may benecessary. 2. Field SuppfredFanSheaveAK41required .FlddSuppliedBeamaybenecessary, .10 .20 .30 CFM RPM BHP FFM 8HP .... BHP 14IPStarderd Motor& Field Supplied Low Stage Chive (1) 960 583 0.13 639 0.18 707 0.23 1080 611 0.18 685 0.23 1 748 0.28 1200 660 0.23 732 0.29 792 0.34 1320 711 0.29 1 781 0.36 838 0.42 1440 782 0.37 829 0.44 885 0.51 896 731 Ise 806 844 766 806 847 890 935 For Standard Evaporator Fan Speed (RPM), reference appaopriatetable. Notes: Date includes pressure drop due to standard fitters and wet coils. Fan Motor Heat (MBH) • 2.629 x Fan BHP,.4024. 1. Field Suppiled Fan SheaveAX69 required.Floid Supplied BM may be necessary. 2. Field Supplied Fan SheanAK41 required. Field Supplied Belt maybe necessary. External Static Pressure (Inches of Water) .40 .50 .60 .70 .80 FPM BP FFM BP FPM BP FFM BHP RPM BP 1-HP Standard Motor & Drive 0.23 028 0.33 0.40 0.47 747 780 815 832 890 Table 7 - Continued CFM 0.28 0.34 0.40 0.48 0.57 817 858 899 940 983 0.27 0.32 0.38 0.45 0.53 0.33 0.39 0.48 0.55 0.64 798 828 859 896 931 864 905 945 986 1028 Table 8 - Continued 960 1080 1200 1320 1440 0.32 0.37 0.43 0.51 0.59 0.39 0.45 0.53 0.61 0.71 144P Standard Motor & Drive 1056 0.86 1090 1096 0.76 ( 1128 1135 0.87 1168 1177 0.98 1209 1217 1.10 1250 6 841 870 901 935 970 908 947 989 1029 1070 0.71 0.82 0.93 1.06 1.18 0.36 0.42 0.49 0.56 0.65 0.44 0.61 0.59 0.68 0.79 894 912 942 974 1009 947 988 1029 1070 1111 0.42 0.47 0.54 0.62 0.71 Factory supplied motors. In commercial equipment, are definite purpose motors, specifically designed and tested to operate ratably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result In nuisance tripping or premature motor failure. Our product's warranty will not be affected. External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 14P Standard Motor & Dew. 980 1005 0.58 1041 0.64 1076 0.70 1110 0.76 I 1142 1080 1029 0.66 1084 0.71 1099 0.77 1 1133 0.83 1166 1200 1053 0.72 1089 0.78 11123 0.85 1156 0.91 1189 1320 1082 0.80 1116 0.87 1150 0.93 1182 1.00 1214 1440 1113 0.90 1146 0.97 1178 1.04 1209 1.11 1240 14IP Standard Motor & Field Supplied High Static Chive (2) Table 8 - Belt dive Evaporator Fan Performance - 3 Ton - YSCO36A3,A4A•H - High Heat - Horizontal Airflow External Static Pressure (Inches of Water) .40 .50 .80 .70 .80 FFM BHP FPM BHP FR A BP FFM BP FFM B4r 14PStende dMotor&Drive 0.49 0.58 0.68 0.78 0.86 .90 1.00 WM SP FPM BHP 926 0.47 962 0.53 980 060 1012 0.68 1045 0.77 0.82 0.90 0.98 1.07 1.18 .90 RPM BHP 985 0.55 1020 0.60 1026 0.64 1061 0.70 1066 0.73 1102 0.80 1106 0.83 1 1142 0.90 1148 0.94 1183 1.02 14IP Standard Motor & Field Supplied High Static Drive (2) Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance topping or premature motor failure. Our product's warranty will not be affected. 968 991 1017 1048 1060 External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1- P Standard Motor & Reid Supplied High Static Deity (2) 1123 0.78 1156 0.84 1188 1159 0.88 1190 0.94 1220 1199 1.00 1229 1.07 1259 1241 1.14 1270 1.21 1299 1281 1.27 1311 1.35 1339 0.52 0.59 0.66 0.74 0.84 1.00 FPAA 84P 0.90 1.00 1.13 1.28 1.43 Table 10— Static Pressure Drops Through Accessories (Inches Water Column) Tons Model No CFM Fitters' Pleated Filters Dannibry Horizontal 960 0.03 0.05 0.05 0.01 0.05 0.00 3 YSCO38A 1200 0.04 0.07 0.07 0.02 0.07 0.01 1440 0.06 0.10 0.10 0.03 0.10 0.01 Notes: 1. Tested with 1 fitters. Difference In pressure drop should be considered when Utilizing optional 2' pleated filters. 2 OA. Outside Air and RA. Return Air. Table 11— Outdoor Sound Power Level - d8 (ref, 10 Watts) Unit Octave Center Frequency Overall Tons Model No. 63. 125 250 530 1000 2000 4000 8000 dBA 3 YSCO33A 86 83 81 80 78 74 69 68 83 Note: TestsfoilowARI27085. Table 9— Standard Motor & Sheave/Fen Speed (Rpm) Unit 6TUrns STums 411ens 3Ti1ms 2Turns 1Tum Tons Model No. Open Open Open Open Open Open Closed 3 YS00384 NA 745 819 894 988 1043 1117 Factory sat at 3 turns open. Economizer with ONRA Dampers Unit Standard 2 Inch 100% OA 100% RA 100% OA 100% RA Table 12 — Gas - Fwed Heating Capeciti s Tons 3 Unit Heating Heating Ak Temp: Efficiency Model No. Input MBH Output MBH Rise. F YSCO38A1•L 60 47 25-55 YSCO36A3, M, AWL 60 48 25-56 Standard YSCO38A1'M 80 63 35-65 YSCO38A3, A4, AW M 80 64 35-65 YSCO36A1•11 120 95 55-85 YSCOOBA3, A4, AW H 120 96 55-85 7 Tkbb13 - Unit Wring Standard Effidency Tons 3 Unit Model No. YSU]0bA1 YS W36A4 YSCO36AW Notes: 1. HACRbreakerperNEC Una Operating Wage Range ld /•Zbd 187-253 517633 DM, 14 - Electrical Characteristics - Evaporator Fan Motors - Direct Drive Unit Tons Model No. YSCO3641 YSC00613 YSCO36A4 YSCO364W Unit Tons Model No. YSCO3641 3 YSCO3643 YSCO36A4 YSC0.364W Nor 1 1 1 1 Standard Evaporator Fan Motor Na Was Phase 1 206-230 T 1 208 -230 1 1 460 1 1 575 1 Table 15 - Ebctdcal CharacterbNd - Evaporator Fan Motors - Belt Drive Tons 3 Standard Indoor Fan Motor Minimum Maximum Fuse Circuit Size Or Maximum Ampacity Circuit Breaker' Ib,3 40 17.9 25 9.2 15 7.7 15 Table 16 - Electrical Characteristics - Compressor Motor And Condenser Motor - Standard Efficiency Wits Phase 208 -230 1 208 -230 3 460 3 575 3 Unit Model No YSC836a3 YSC008M Y500364W FP RA LRA Na .33 2.30 3.90 1 .33 2.30 3.90 1 .33 1.10 2.00 1 .33 1.10 1.80 1 Compressor Motor Condenser Fan Motors 3.1 3.1 3.1 3.1 8 RRW 3450 3450 3450 3450 Oversize Indoor Fan Motor Mrrnxm Maximum Fuse Circuit Size Or Maximum Ampacity Circuit Breaker' /./ 40 20.3 30 10.4 15 8.3 15 Amps 7Lble 17 - Electrical Characteristics - inducer Motor Una Model No, YSCO36J1 Na Amps RA LRA 17.2 104.0 11.3 74.0 6.0 37.6 4.9 30.4 Was Phase 208 -230 3 460 3 575 3 lP 1/35 Belt Drive Indoor Fan Motor Minimum Maximtrn Fuse Circuit Size or Maximum Ampacity Circuit Breaker' 20.6 30 10.6 15 8.3 15 Oversized Evaporator Fan Motor Wits 208 -230 206 -230 460 460 Na 1 1 1 1 Phase I-P 1 .50 1 .50 1 .50 1 .50 Phase 1 1 1 1 FP FLA LRA 1.0 5.0 32.2 1.0 2.5 16.1 1.0 1.7 13.2 FP .20 .20 .20 .20 Amps RA URA 4.70 9.80 4.70 9.80 2.30 5.20 1.70 3.60 Amps Amps FLA LRA 1.6 2.5 1.5 2.5 0.6 1.3 0.5 1.2 WM Was Phase LRA 3000 208230 1 0.6 All dimensions are in inches/millimeters CLEARANCE 3T (940 MM) 9 0 ((011MN) CLEARANCE 48' (1219 MM) 3/4. 4 NFT ALTERNATE DRAIN CONNECTION ROOF OPENING 37. CLEARANCE ok HORIZONTAL O 1r (457 DOWNFLOW 98 (914 MM)) MM) CLEARANCE 3r (914 MM) 4 All dimensions are in inches/millimeters. Dbwnllow. Duct Connections — Reid Febrkebd 243/6' (619 MM) F ( 357 MM i.Z 10 16 3/16' I (411 MM) 18 1/16' (459 MM) ALL FLANGES 1 1/4' (32 MM) NOTICE: IF THE DOCUMENT I THIS FRAME IS LESS CLEAR1 HAN.. THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. All dimensions are in inches. A CENTER OF GRAVITY WIDTH I CENTER OF GRAVITY mo— LENGTH -------b- CENTER OF GRAVITY Did* 18 Maxirnum Unit And Cotner Might, frees) And Center Of Gravity Dimensions fin) Unit Maximum Weights (Lbslr Corner Weights (Lbs)1 Notes: 1. Corner weights are given for information only. 2. Weights ereepproxinate. 12 Table 19 — FacforyJnsta9ed Options Net Weights (L6s ? Barometric Relief 7 Motorized Outside As Damper 20 Manual Outside Air Damper 18 Roof Curb 70 Oversized Motor 5 Belt Drive Motor 31 Smoke Detector, Return 7 Smoke Detector, Supply 5 Col Guards 12 Hinged Doors 10 Powered Convenience Outlet 38 Through the Base Electrical 8 Through the Base Gas 5 Unit Mounted Circuit Breaker 6 Unit Mounted Disconnect 5 Novar Control 8 Notes: 1•Weights for options not listed are >5 lbs. 2.Net weight should be added to unit weight when aderinglactory•instelledaccessories. B C Center of Gravity (Ir.) Tore Model No. Stippig Net A B C D Length Width 3 YSCO38A 572 480 151 124 96 109 32 19 Accessory Weight Eoo wizer 26 { Please Note: Mechanical Specifications may or may not apply to all models. General The units shall be convertible airflow. The operating range shall be between 115 °F and 0 °F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115 °F and 40°E Cooling performance shall be rated in accordance with MI testing procedures. All units shall be factory assembled, internally wired, fully charged with R -22, and 100 percent run tested to clhedc cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/CAN/CSA No. 236 -M90 for Central Cooling Air Conditioners. Canadian units shall be CSA Certified. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather - resistant baked enamel finish. Unit's surface shall be tested 1000 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing only a single fastener while providing a water and airtight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire- retardent permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/2 inch, 1 pound density foil- faced, closed -cell material. All insulation edges shall be either captured or sealed The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1h/ inch high downflowsupply/ return openings to provide an added water integrity precaution, if the condensate drain backs up.The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Mechanical Specifications UnitTop The top cover shall be one piece construction or where seams exist, it shall be double- hemmed and gasket - sealed. The ribbed top adds extra strength and prevents water from pooling on unit top. Filters One inch, throwaway filters shall be standard on all 3-5 ton units.The filter rack can be converted to two inch capability.Two inch filters shall be factory supplied on all 6-10 ton units. Optional 2 -inch pleated filters shall be available. Compressors All 3 ton standard units shall have direct- drive, hermetic, reciprocating type compressors.The reciprocating type compressors have a centrifugal oil pump providing positive lubrication to moving parts. Motor shall be suction gas - cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Crankcase heater, internal temperature, and current- sensitive motor overloads shall be included for maximum protection. Compressors shall have internal spring isolation and sound muffling to minimize vibration transmission and noise. Low pressure switches shall be standard. 3 ton high efficiency and 4-10 ton standard and high efficiency units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas - cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Crankcase heaters shall be included on 7' /s ton standard efficiency units. Refrigerant Circuits Each refrigerant circuit offers a choice of independent fixed orifice expansion devices or thermal expansion valve. Service pressure ports, and refrigerant line filter driers are factory- installed as standard. An area shall be provided for replacement suction line driers. 13 Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Coils shall be leak tested at the factory to ensure the pressure integrity.The evaporator coil and condenser coil shall be leak tested to 200 psig and pressure tested to 450 psig.The condenser coil shall have a patent pending 1 +1 +1 hybrid coil designed with slight gaps for ease of cleaning. A removeable, reversible, double - sloped condensate drain pan with provision for through the base condensate drain is standard. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes.The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field - installed kit) and also comply with the California requirement for low NOx emissions. Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw- through in the vertical discharge position.The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan All 3-5 ton 3 -phase units offer a choice of direct - drive, FC, centrifugal fans or belt driven, FC centrifugal fans with adjustable motor sheaves. 3-5 ton direct drive oversized motors shall be available for high static operations. All 6- 10 ton units shall have belt drive motors with an adjustable idler -arm assembly for quick- adjustment to fan belts and motor sheaves. All motors shall be • thermally protected.All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Controls Unit shah be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24 volt control functions.The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures.The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort A centralized Microprocessor shall provide anti- short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor pressure lugs for power wiring. Units shall have single point power entry as standard. Mechanical Specifications Factory Installed Options Black Epoxy Coated Condenser Coil The coil provides corrosion protection to condenser coils for seacoast application. The protection is thermoset vinyl coating, bonded to normal aluminum fin stodk.The uniform thickness of the bonded vinyl layer exhibits excellent corrosion protection in salt spray tests performed in accordance with ASTM B117. Dehumidification Option The dehumidification (hot gas reheat) option shall provide increased dehumidification.The option shall consist of a hot -gas reheat coil located on the leaving air side of the evaporator coil prepiped and circuited. The option shall be equipped with crankcase heater(s), low pressure switch(es), Frostatm, and a thermostatic expansion valve(s) (TXV) as standard. High Pressure Cutout This is offered for units that do not have High Pressure cutout as standard. All 3- phase units with scroll compressors include High Pressure Cutout as standard. Hinged Access Doors Sheet metal hinges are available on the Filter/Evaporator, Supply Fan/Heat, and the Compressor/Control Access Doors. Novar Return Air Sensor This option, when used in conjunction with Novar Controls, will contain a factory provided and wired zone temperature sensor located in the return air stream. Novar Unit Controls Optional Novar rooftop unit controls shall be installed and tested. The Novar electronic thermostat module will interface to the unit microprocessor and will control the unit to the desired stage of cooling or heating. 14 a Phase Monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. Powered or Unpowered Convenience Outlet This is a GFCI, 120v/15amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available.The convenience outlet is powered from the line side of the disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker.This option can only be ordered when theThrough the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Supply and/or Return Air Smoke Detector With this option, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit RetumAir Smoke Detectors require minimum allowable airflow when used with certain models. See the Installation, Operation, and Maintenance (IOM) manual for the models affected and the minimum allowable airflow required. This option is available for microprocessor controlled units. Thermal Expansion Valve All units shall have a short orifice refrigerate control metering device. For more exact refrigerant flow, when using unit in low airflow applications, a Thermal Expansion Valve option shall be available. Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections Inside the curb and through the base of the unit. Option will allow for field installation of liquid -tight conduit and an external field- installed disconnect switch. Through the Base Electrical with Circuit Breaker This option is a thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections.The circuit breaker will be installed in a water tight enclosure in the unit with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal blodc.The circuit breaker will provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UUCSA. Through the Base Electrical with Disco'mert Switch This 3 -pole, molded case, disconnect switch with provisions for through the base electrical connections are available.The disconnect switch will be installed in the unit in a water tight enclosure with access through a swinging door.Wiring will be provided from the switch to the unit high voltage terminal blodc.The switch will be UV CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit overcurrent protection. Through the Base Gas Piping The unit shall include a standard through the base gas provision.This option shall have all piping necessary Including, bladc steel, manual gas shut- off valve, elbows, and union.The manual shut-off valve shall include a 1/8" NPT pressure tap.This assembly will require minor field labor to install. Two -Inch Pleated Rters Two inch pleated media filters shall be available on all models. Factory or Field Installed Options Clogged Filter/Fan Failure Switch A dedicated differential pressure switch is available to achieve active fan failure indication and/or dogged filter indication.These indications will be registered with a zone sensor with status Indication lights.This option is available for microprocessor controlled units. Mechanical Specifications Differential Pressure Switches These sensors allow individual fan failure and dirty filter indication for microprocessor controlled units.The fan failure switch will disable all unit functions and "flash" the Service LED on the zone sensor.The dirty filter switch will light the Service LED on the zone sensor and will allow continued unit operation. Discharge Air Sensing This option provides true discharge air sensing in heating models. This option is available for microprocessor controlled units. Economizer This accessory shall be available with or without barometric relief.The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control.The barometric relief shall provide a pressure operated damper that shall be gravity dosing and shall prohibit entrance of outside air during the equipment "off" cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation.The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Be ctric Heaters Electric heat modules shall be available for installation within basic unit. Electric heater elements shall be constructed of heavy -duty nidcel chromium elements internally delta connected for 240 volt, wye connected for 480 and 600 volt. Staging shall be achieved through ReliaTel'". Each heater package shall have automatically reset high limit control operating through heating element contactors. All heaters shall be individually fused from the factory, where required, and shall meet all NEC and ac requirements when properly installed. Power assemblies shall provide single -point connection. Electric heat modules shall be UL listed or CSA certified. 15 Frostat This option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°E The temperature will need to rise to 50°F before closing.This option should be utilized in low airflow or high outside air applications. Oversized Motors Direct drive oversized motors shall be available for high static applications. Reference or Comparative Enthalpy Reference Enthalpy is used to measure and communicate outdoor humidity.The unit receives and uses this information to provide improved comfort cooling while using the economizer. Comparative Enthalpy measures and communicates humidity for both outdoor and return air conditions, and return air temperature.The unit receives and uses this information to maximize use of economizer cooling, and to provide maximum occupant comfort control. Reference or Comparative Enthalpy option shall be available when a factory or field installed Downflow Economizer is ordered. Tool-less Hail Guards Tool -less, hail protection quality coil guards are available for condenser coil protection. Field Installed Options co, Sensing Osensor shall have the ability to monitor space occupancy levels within the building by measuring the parts per million of CO (Carbon Dioxide) In the air. As the CO levels increase, the outside air damper modulates to meet the CO space ventilation requirements. Digital Display Zone Sensor The Digital LCD (Liquid Crystal Display) zone sensor has the look and functionality of standard zone sensors. This sensor indudes a digital display of set point adjustment and space temperature in F (Fahrenheit) or C (Celsius). lndudes FAN and SYSTEM buttons (supports the service functions of the standard sensor). E- squared memory stores last programmed set points. Requires 24VAC (Volts AC).This sensor should be utilized with ReliaTeP controls. DualThermistor Remote Zone Sensor This sensor will allow the customer to reduce the total number of remote sensors to obtain space temperature averaging. This sensor should be utilized with ReliaTel controls. High Static Drive The high static drive option shall allow the standard motor on the 6 and T1 ton units to operate with improved external static capabilities. Humidity Sensor This wall- mounted humidity sensor is used to control activation of the hot gas reheat dehumidification option.The humidity sensor can be set for humidity levels between 40% and 60% relative humidity by adjusting the ReliaTel Options Module. American andrdha harapoicyaroollnwrprodxrad prodddetai povrn ntandrssaraerrnbMb sodapidiaforrwrqutno a. Technical Literature Printed In USA ©2004 American Standard Inc. All rights reserved Mechanical Specifications Humidity Sensor This duct - mounted humidity sensor is used to control activation of the hot gas reheat dehumidification option.The humidity sensor can be set for humidity levels between 40% and 60% relative humidity by adjusting the ReliaTel Options Module. Manual Outside Air Damper This rain hood and screen shall provide up to 50 percent outside air. Motorized Outside Air Dampers Manually set outdoor air dampers shall provide up to 50 percent outside air. Once set, outdoor air dampers shall open to set position when indoor fan starts.The damper shall dose to the full closed position when indoor fan shuts down. Powered Exhaust The powered exhaust, available for 6-10 ton units, shall provide exhaust of return air, when using an economizer, to maintain better bulding pressurization. Remote Potentiometer The minimum position setting of the economizer shall be adjusted with this accessory. Roof Curb The roof curb shall be designed to mate with the unit's downflow supply and return and provide support and a water tight installation when installed properly. The roof curb design shall allow field- fabricated rectangular supply /return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall be shipped knodced down for field assembly and shall include wood nailer strips. 16 Library Product Section Product Model Literature Type Sequence Date File No. Supersedes Thermostat Two stage heating and cooling operation or one stage heating and cooling shall be available in either manual or automatic changeover. Automatic programmable electronic with night set back shall also be available. Ventilation Override Accessory With the Ventilation Override Accessory installed, the unit can be set to transition up to 3 different pre - programmed sequences for Smoke Purge, Pressurization, and ExhaustThe transition occurs when a binary input on the RTOM is dosed (shorted).This would typically be a hard wired relay output from a smoke detector or fire control panel.The ventilation override accessory shall be available as field installed. Zone Sensor This control shall be provided to interface with the Micro equipped units and shall be available in either manual, automatic programmable with night setback, with system malfunction lights, or remote sensor options. Product Literature Unitary Packaged Gas /Electric Rooftop YSCO36A — 3 Ton Submittal 200.05 June 2004 PL -UN -RT YSCO36 -SQ- 200.05 06/04 PL -UN -RT YSCO36 -SO- 200.04 02/04 Job Name: Purchaser: Engineer. Submitted To: Submitted By: Unit Designation: Schedule No. Capacities: Cooling 18.5 MBH Outdoor Design Temp °F DB/WB Cooling 95/75 EER 10.6 SEER 11.3 Indoor Unit: Power Supply (V /PH/ Hz) 115/1/60 Max. Fuse Size 15 Amps Min. Ampacity 1 Amps Weight 53 Lbs. Sound dB(A) L- 35/H -43 Outdoor Unit: Power Supply (V /PH/ Hz) 208 - 230/1/60 Max. Fuse Size 20 Amps Min. Ampacity 16 Amps Weight 154 Lbs. Refrigerant Piping: Max. Ht. Difference 130 Ft. Max. Length 130 Ft. Liquid (OD) 3/8 In. Gas (OD) 5/8 In. Standard Features: • Six year compressor warranty • One year parts warranty • Auto restart following a power outage • Advanced Microprocessor controls • Slim -line outdoor unit • Refrigerant charge for up to 100 feet of piping • Zone control • Quiet operation - both, indoor and outdoor units • On /Off timer • Self Diagnostics • Condenser fan control down to 0°F. *Requires low ambient wind baffle PU18EK I' PK18FK3 Location: For: ❑ Reference 0 Approval ❑ Construction Date: Model No.: Submittal Data: PK18FK3 & PU18EK e . MITSUBISHI ELECTRIC Dimensions — Inches 34 -1/4 "> pow 55 -1/8" 33 -1/2" PU18EK LJo 11 -5/8 " r 13 -3/8" C 9 -1/4 "I Notes: SSD PK18FK3 022803 ®Mitsubishi Electric 2003/ ACTIVITY NUMBER: PROJECT NAME: PERMIT COORD PLAN REVIEW /ROUTING SLIP M04 -188 BLACK BOX SITE ADDRESS: 200 ANDOVER PARK EAST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPA TMENTS: 141,0( 1 B i iligftron �] Public Works ❑ ego Pik 10-2-494/ Fire Fire Prevention Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents /routing slip.doc 2.28.02 Incomplete ❑ REVIEWER'S INITIALS: DATE: 10 -22 -04 DUE DATE: 10 -26 -04 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO)JTING: Please Route IJ,( Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -23 -04 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PER ,Irr r'nnPn COPY DRAWING INDEX __ NO MEET TITLE M0.00 � LEGEND, ABBREVIATIONS, GENERAL NOTES, SHEET INDEI( - HVAC 02.01 ---- 11RST FLOOR PLAN, ROOF PLAN & SCHEDULES - HVAC A AC ACT AD AFF AFC AHU ALAI AP ARCH BC BDD BF ROT HVAC ABBREVIATIONS AMPS AIR CONDITIONING ACOUSTICAL TILE CEIUNG ACCESS DOOR ABOW FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDUNG UNIT ALUMINUM ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BOTTOM BS BIRD SCREEN BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNITS PER HOUR CD:COND CEILING DIFFUSER; CONDENSATE DRAIN CFM CLG COL CONC CONN CONTR DB DIA DDC DMPR ON +DWG EXH EA EAT EG EC EF EL ELECT. 'EP EQUIP ESP EWT EXIST FD FDC FLA FLR FOB FOS FOT FP FPM FT FUT GA GALV GC GR GRD GWB HWTG HP HR CUBIC FEET PER MINUTE CEILING COLUMN CONCRETE CONNECT CONTRACTOR DRY BULB DIAMETER DIRECT DIGITAL CONTROLS DAMPER DOWN DRAWING EXHAUST . EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE END CAP; ELECT. CONTR. EXHAUST FAN ELEVATION ELECTRICAL END PLUG EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FIRE DAMPER FIRE DEPARTMENT CONNECTION FULL LOAD AMPS FLOOR FLAT ON BOTTOM FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FOOT or FEET FUTURE GAUGE GALVANIZED GENERAL CONTRACTOR GRILLE GRILLE; REGISTER; DIFFUSER GYPSUM WALL BOARD HIGH WALL TRANSFER GRILLE HORSEPOWER HOUP i HT ID IN IN WG LD,LIN DIFF LF,LIN FT LWG LWR MAX MAJ MBH MCA MIN MD MTC NC NIC NO OA 08 OD PCF PD POC PSI PSIG RA REG REQ'D Rr RG RL RS SA SD S/D S /FD,FSD SG SL SM SO SQFT SS TA TG TOC TOS TOT TSTAT TYP UH LINO V VD VFD WB WG W/ W/O WSF HVAC GENERAL NOTES HEIGHT INSIDE DIAMETER /DIMENSION INVERT ELEVATION INCHES INCHES WATER GAGE LINEAR DIFFUSER LINEAL FEET /FOOT LOW WALL GRILLE LOW WALL REGISTER MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS MINIMUM CIRCUIT AMPACITY MINIMUM MOTORIZED DAMPER MOUNTED NORMALLY CLOSED; NOISE CRITERIA NOT IN CONTRACT NORMALLY OPEN OUTSIDE AIR OPPOSED BLADE OUTSIDE DIAMETER /DIMENSION POUNDS PER CUBIC FOOT PRESSURE DROP POINT OF CONNECTION POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE RETURN AIR REGISTER REQUIRED RELIEF RETURN GRILLE REFRIGERANT LIQUID REFRIGERANT SUCTION SUPPLY AIR SMOKE DETECTOR SLIP & DRIVE CONNECTION SMOKE FIRE DAMPER SUPPLY GRILLE SOUND LINED SPIRALrr►ATE OR SHEETMETAL SCREENED OPENING SQUARE FEET STAINLESS STEEL TRANSFER AIR TRANSFER GRILLE TOP OF CONCRETE; CURB TOP OF STEEL TOTAL THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLTS VOLUME DAMPER VARIABLE FREQUENCY DRIVE WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT 6 RECTANGULAR DUCT K ' IL RECTANckJ(JIR DUCT r RECTANGULAR DUCT 1 / ROUND DUCT S i ROUND DUCT OVAL DUCT OVAL DUCT r - I 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS OTHERWISE NOTED. 3. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 4. VERIFY ALL EXISTING CONDITIONS. DIMENSIONS, DETAILS, ETC. NOTIFY ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 5. WHEN CONSTRUCTIONS DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS, AND PLATFORMS BE BY THE GENERAL CONTRACTOR UNLESS OTHERWISE NOTED. 7. ALL JOINTS IN SUPPLY AND RETURN AIR DUCTS SHALL BE SEALED. 8 ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS OTHERWISE NOTED. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. 10.OUTSIDE AIR INTAKES ON ALL AIR CONDITIONING UNITS SHALL BE EITHER 3 FEET BELOW OR 10 FEET AWAY, FROM ANY FUEL BURNING EQUIPMENT. 11.INSULATE DUCTS AS SHOWN ON PLANS. INSULATION TO COMPLY WITH THE LATEST APPROVED VERSIONS OF THE UNIFORM MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION. SEE ENERGY CODE TABLE 14 - 5 FOR COMPLYING THICKNESS AND DENSITIES. - FOR BOTH SUPPLY AND RETURN DUCTS LOCATED IN UNCONDITIONED SPACE (ROOF, ATTIC, GARAGE, ETC.), INSULATE TO AT LEAST R -7.0. DUCTWORK EXPOSED ON ROOF TO BE EITHER INTERNALLY LINED OR EXTERNAL WRAP WITH ALUMINUM JACKET. -FOR OUTSIDE AIR DUCTS LOCATED IN CONDITIONED SPACE, INSULATE TO BUILDING ENVELOPE (WALL) INSULATION VALUE, UNTIL THE POINT Of CONNECTION TO EITHER THE MECHANICAL EQUIPMENT OR TO A SHUTOFF DAMPER TO ISOLATE FROM THE OUTSIDE. DUCTWORK DOWNSTREAM OF A SHUTOFF DAMPER SHALL BE INSULATED TO AT LEAST R -T.O. -FOR BOTH SUPPLY AND RETURN DUCTS OR OUTSIDE AIR INTAKE DUCTS LOCATED II UNCONDITIONED SPACE ON CONCRETE OR IN GROUND), INSULATE TO AT LEAST R -5.3. DUCTWORK SHOULD BE SEALED WATER TIGHT AND PROTECTED FROM DAMAGE DURING THE FILL PROCESS. -FOR TYPICAL SUPPLY AIR DUCTS WITH AIR TEMPERATURES < 55'F OR > 105'F LOCATED IN RA PLENUMS INSULATE W/ DUCT UNER, MINERAL FIBER BLANKET OR EQUAL TO AT LEAST R -3.3. - MECHANICALLY COOLED DUCTS REQUIRE A VAPOR RETARDER ( <0.5 PERM RATING) AND SEALED JOINTS. 12.ALL AIR ECONIMIZERS SHALL BE CAPABLE OR THE FOLLOWING: A. 0% TO 100% OF THE DESIGN SUPPLY AIR B. CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. C. INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. B.D.D. AD asiasommumg FLEX i L TRANS. T.V. AIR FLOW DIRECTION SUPPLY AIR DUCT TURNING UP OR TOWARD SUPPLY AIR DUCT - TURNING DOWN OR AWAY EXHAUST OR RETURN AIR DUCT - TURNING UP OR TOWARD EXHAUST OR RETURN AIR DUCT - TURNING DOWN OR AWAY ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING DOWN OR AWAY OVAL DUCT = TURNING UP OR TOWARD OVAL DUCT - TURNING DOWNN OR AWAY CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION . TURNING VANES • DETECTORS, FIRE AND /OR SMOKE BACK DRAFT DAMPER • DUCT ACCESS DOOR FLEXIBLE DUCT BS BIRDSCREEN OR SCREENED OPENING SUPPLY GRILLE ---'v- RETURN OR EXHAUST GRILLE VD VOLUME DAMPER MD MOTOR OPERATED DAMPER SD IONIZATION DUCT SMOKE DETECTOR EXISTING DUCTWORK DEMO DUCTWORK HVAC LEGEND • Frin. FIRE DAMPER riln /FD COMBINATION SMOKE & FIRE DAMPER SD SMOKE DAMPER ST SOUND TRAP AD ACCESS DOORS SL ACOUSTICALLY LINED DUCT DB DUCT BOARD VAV BOX Od R -100 S - E -100 OA -100 •CD1 100 -CFM 80 EACH � SIZE (T. CD RA,TA, EG TYPE CODE FC METAL FAB FLEX CONNECTION CEILING SUPPLY AIR DIFFUSER (SHOWN WITH REDIRECTED AIR CORE) `.; LD LINEAR DIFFUSER (CEILING) LD LINEAR DIFFUSER (WALL) GRD SYMBOL II 3.OUTSIDE AIR INTAKE RELIEF AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 14.THE CONTROL SYSTEM SHALL BE 7 DAY PROGRAMABLE CAPABLE OF BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK AND HAVE DEADBAND SETTING OF AT LEAST 5T. BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE MICROPROCESSOR AND BE CAPABLE OF RESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 15.RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER. FOR ALL OTHER SYSTEMS, HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD - WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER. 16.DUCT SYSTEMS SHALL COMPLY WITH MECHANICAL CODE AND SMACNA STANDARDS. DUCTS 28" AND LARGER WHICH ARE SUSPENDED MORE THEN 12" BELOW STRUCTURAL SYSTEM SHALL BE EARTHQUAKE BRACED. 17.PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT AS REQUIRED. 18.PROVIDE FIRE AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 19.ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN APPROVED FIRE CAULKING 20.FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM, SMOKE DETECTORS SHALL BE PROVIDED FOR AUTOMATIC SHUTDOWN PER CODE. UNLESS NOTED OTHERWISE, SMOKE DETECTORS INSTALLED BY ELECTRICAL, PROVIDED BY ELECTRICAL. POWER- WIRING AND INTERLOCK TO FIRE ALARM BY ELECTRICAL AS APPLICABLE. 21 ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL AND INSTALLED BY THE GENERAL. 22.ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT $cHEDUIFS ARE PROVIDED AND INSTALLED BY ELECTRICAL. r • .1' it►: CEILING RETURN,TRANSFER OR EXHAUST AIR GRILLE LVR LOUVER PLAN VIEW ROUND DUCT SYMBOL _ FLAT OVAL DUCT SYMBOL RETURN AIR; NUMBER INDICATES CFM QUANTITY SUPPLY AIR; NUMBER INDICATES CFM QUANTITY EXHAUST AIR; NUMBER INDICATES CFM QUANTITY OUTSIDE AIR; NUMBER INDICATES CFM QUANTITY , , r TEMPERATURE SENSOR HUMIDITY SENSOR • STATIC PRESSURE SENSOR POINT OF NEW CONNECTION et PARCEL A AND B: THAT PORTION ON TRACT 10 OF ANDOVER INDUSTRIAL PARK NO. 2, AS PER PLAT RECORDED IN VOLUME 71 OF PLA IS, PAGE 68, RECORDS OF KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHEAST OF SAID TRACT 10; THENCE N 01 11' 25" E ALONG THE WESTERLY MARGIN OF JAMES CHRISTENSEN ROAD, A DISTANCE OF 105.99 FEET TO THE TRUE POINT OF BEGINNING; THENCE N 88'54'54" W, A DISTANCE OF 284.96 FEET TO A POINT ON THE EASTERLY MARGIN OF ANDOVER PARK EAST; THENCE N 01'05'06" E ALONG SAID EASTERLY MARGIN, A DISTANCE OF 354.02 FEET TO A POINT OF CURVE; THENCE ALONG A CURVE TO THE RIGHT HAVING A RADIUS OF 50.00', AN ARC DISTANCE 78.97 FEET TO A POINT ON THE SOUTHERLY MARGIN OF BAKER . BOULEVARD; THENCE S 88'25'27" E ALONG SAID SOUTHERLY MARGIN, A DISTANCE OF 185.61 FEET TO A POINT OF CURVE; THENCE ALONG A CURVE TO THE RIGHT, HAVING A RADIUS OF 50.00 FEET, AN ARC DISTANCE OF 76.20 FEET TO A POINT ON THE WESTERLY MARGIN OF THE JAMES CHRISTENSEN ROAD; THENCE S 01'11'25" W, A DISTANCE OF 352.34 FEET TO THE TRUE POINT OF BEGINNING . ,1 • • APN NUMBER ,� ;o = � _ � LEGAL DESCRIPTION VICINITY MAP MAPS �; • • 23.FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: -ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY G.C.) -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY G.C.) -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL IS NOT ACCEPTABLE (BY G.C.) . . - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHOULD BE SEALED ON BOTH SIDES OF THE PENETRATION. . -USE SECTION 905 OF THE 1997 UBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE . GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. - ALL DOORS MUST BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. . 24.FLEXIBLE DUCTWORK MAXIMUM LENGTH TO BE 12'. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING < 25 AND SMOKE DEVELOPED RATING < 50. FLEXIDUCT MODEL G- KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED, WITH INSULATION AS NOTED IN NOTE 11 ABOVE. 25.LOCATION AND DETAIL OF EQUIPMENT. DUCT ROUTING AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS AND INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND SHOP DRAWINGS. it)8 •• w, R • WM a4illeiM.s ,1es..0 WO. NAVVIdat s, SITE PLAN 1 Wools !BUILDING DIVISION t FILE COPY / Penult No. /04- Plan review approval is subject to errors and wisdom :flhd.I r of construction documents does not authoi the won of any adopted code or ordinance. Re's df approved and conditions is adcncoledgui: titicitneD Crry OF TUKWILA OCT 2 2 as PERMIT CENTER ISSUE FOR PERMIT PlAtoor P oisca'1o4-106 glad SON . SmillmmeramPEnOvoliellwaclOAD x.003. tapdt *MOW 6 Mt aye , WC •••• - •1.. vµ BLACK BOX TI @ SOUTHCENTER ) Hermanson 1 1 He � P LIP Kent, Washington 98032 Tel. (206) 575 -9700 , Fax: (206) 575 -9800 www. hermanson.com Contractor Reg 1: Design Checked 200 ANDOVER PARK E. TUKWILA WA. 98188 EXPRES 1/29/0 .Revisions Drawn ER • 1 Project Number 10 -4 -106 Issue Date 10/20/04 10/20/04 DN PERMIT SET No. • Date By Description Design Team DN ON Scale AS NOTED Drawing Number ' C- 0024 -106 . LEGEND, ABBREVIATIONS, GENERAL NOTES, SHEET INDEX - HVAC M0.00 M04188 ; "V 1 2 3 4 5 1 STANDARD BRmSH WHITE FINISH 2 SEE DWG FOR THROW PATTERN DESIRED 3 RUN OW SIZE SAME SIZE AS DIFFUSER NECK SCE, II,N.O. 014 OWGS 4 FILTER GRILLE TO BE PROVIDED WITH INTEGRAL FILTER SYMBOL CU-1 X PROVIDE FULL ECONOMIZER CYCLE AND BAROMETRIC RELIEF MINIMUM UNIT EFFICIENCY TO MEET THE WASHINGTON STATE ENERGY CODE TABLE 14 -1 SUPPLY SIDE SMOKE DETECTOR FURNISHED BY MECHANICAL AND INSTALLED BY ELECTRRCAL CONTRACTOR PROVIDE DISPOSABLE FILTERS AND ROOF CURB ADAPTER PROVIDE 24 HOUR PROGAMMABLE STAID -ALONE THERMOSTAT - HONEYWELL T7300 AREA SERVED SERVER ROOM ISIS Of DESIGN MITSUBISHI PU18EK 1. SPLIT SYST(M UNITS REQUIRE DISCONNECT AT THE ROOF CONDENSING (Ni (RY ELECTRIC A. CONTRACTOR) 2. PROVIDE WITH WIRELESS T"STAT, REFRIGERANT CUES ET MC, CONDENSATE PIMP •@rdAW1W' �.el���y„t.lrw• t� raw, w .Sr 'i 3/8" LIO & 5/8" SUCT REFER LINES DN TO FCU -1 IN SERVER RJOM OIADOOR UNIT REO OOOLMG CAP IN STUN TOTAL SENS. 18,000 • E G0M1 MOUNT UNIT ON SLEEPERS (C i - I FCLI- MIT @ 72" AFF. PUMP CONDENSATE © 3/4" TO NEAREST SINK TAIL PIECE I, 4 1 1 1 3/8" LIQ & 5/8 SUCT REFER LINES UP TO CU-1 ON ROOF 0 s HEATING CAP ELEC V 2 PH SPLIT SYSTEM UNIT SCHEDULE MCA 16 WEIGHT IN POUNDS 54 NM/ ROOM WALL ROOF PLAN - HVAC SCALE: 1/4 = 1--0" SCALE 1/4 = 1 • INDOOR Aft HANDLING FAIT BASIS OF LOCATION AREA SERVED DESIGN SERVER ROOM MTTSU BASH I PK 151( FIRST FLOOR PLAN - HVAC BLACK BOX TI SOUTHCENTER 111 . 11 )1, Hermanson No. pate By Description Drawn 200 ANDOVER PARK E. TUKWILA WA. 98188 I EXPIRES 1/29/06 10/20/04 DN PERMIT SET Design Team DN Checked DN AS NOTED Drawing Number C- 0024 -106 Project Number 10 -4 -106 Issue Date 110/20/04 FIRST FLOOR PLAN, ROOF PLAN & SCHEDULES HVAC IAN OA CPA S.P. IN. W.G. 0 NA ELEC HEATER CAP. IN WATTS DT3 - 100 (TYP . 4) CONNECT 1/2" NG TO EXISTING PIPINNG ON ROOF 1\1 0 Last Updated: 10/14/04 WEIGHT IN POUNDS , REMARKS 53 1,2 0 I • L •11i41 /"- - r • • 1 FIELD VERiY FINAL LOCATION WITH EXISTING STRUCTURE • • RTU -1 J ..... .. . . J. . ...jam � .. Y l 1.� • • • REVIEWED FOR CODE C�MPUANC,E POP Al IMO NOY 17 2004 City Of Tukwila _BUILDING DIVISION CrrY AUG ISSUE FOR PERMIT AEC CITY pF OCT 2 PERMIT Pim* , **cam 104-108 Slade Box SedloodeotVadkEnOtoolneloonclIM2 01 dog. LavivM1. *M1 1 1 WS PAM. iwsi •S DIFFUSER AND GRILLE SCHEDULE SST UPDATED: , 0 , 304 UNIT TAG LOCATION AREA SERVED _ SERVICE BASIS OF DESIGN TYPE MOUNTING MATERIAL E.S.P IN. WG. I NECK SIZE FACE SIZE N. G. HEATING CAP. MBH MAX CFM NOISE CRITERIA REMARKS DN. IN SQ. IN DIA. 14 RECT IN DB. DEG. F C01 CEIUNG j SUPPLY INPUT WART & COOLEY 444 SURFMRE T -BAR RPM ALUMINUM TYPE I 6 - , - 24 X 24 MCB 130 20 1,2,3 CO2 CEILING SUPPLY 78.0 HART & COOLEY 444 SURFMRE _ , T -BAR 1,200 ALUMINUM ALUMINUM ALUMINUM _ 0.80 + 8 ..__ 10 12 - - - , - - - 24 X 24 24 X 24 24 X 24 60 225 375 530 22 30 35 1,2,3 1,2,3 1,2,3 CO3 CEILING CENTR. 1 SUPPLY SUPPLY 1 935 HART & COOLEY 444 WRT & COOLEY 444 SURFAIRE SUIRFAIRE T -BAR T -BAR _ 460/3 CD4 COUNG RI CERJNG RETURN ! HART & COOLEY 659T , LOUVERED T -BAR 1 ALUMINUM i - 20 , - 24 X 24 l 1,400 - 1,3,4 1 2 3 4 5 1 STANDARD BRmSH WHITE FINISH 2 SEE DWG FOR THROW PATTERN DESIRED 3 RUN OW SIZE SAME SIZE AS DIFFUSER NECK SCE, II,N.O. 014 OWGS 4 FILTER GRILLE TO BE PROVIDED WITH INTEGRAL FILTER SYMBOL CU-1 X PROVIDE FULL ECONOMIZER CYCLE AND BAROMETRIC RELIEF MINIMUM UNIT EFFICIENCY TO MEET THE WASHINGTON STATE ENERGY CODE TABLE 14 -1 SUPPLY SIDE SMOKE DETECTOR FURNISHED BY MECHANICAL AND INSTALLED BY ELECTRRCAL CONTRACTOR PROVIDE DISPOSABLE FILTERS AND ROOF CURB ADAPTER PROVIDE 24 HOUR PROGAMMABLE STAID -ALONE THERMOSTAT - HONEYWELL T7300 AREA SERVED SERVER ROOM ISIS Of DESIGN MITSUBISHI PU18EK 1. SPLIT SYST(M UNITS REQUIRE DISCONNECT AT THE ROOF CONDENSING (Ni (RY ELECTRIC A. CONTRACTOR) 2. PROVIDE WITH WIRELESS T"STAT, REFRIGERANT CUES ET MC, CONDENSATE PIMP •@rdAW1W' �.el���y„t.lrw• t� raw, w .Sr 'i 3/8" LIO & 5/8" SUCT REFER LINES DN TO FCU -1 IN SERVER RJOM OIADOOR UNIT REO OOOLMG CAP IN STUN TOTAL SENS. 18,000 • E G0M1 MOUNT UNIT ON SLEEPERS (C i - I FCLI- MIT @ 72" AFF. PUMP CONDENSATE © 3/4" TO NEAREST SINK TAIL PIECE I, 4 1 1 1 3/8" LIQ & 5/8 SUCT REFER LINES UP TO CU-1 ON ROOF 0 s HEATING CAP ELEC V 2 PH SPLIT SYSTEM UNIT SCHEDULE MCA 16 WEIGHT IN POUNDS 54 NM/ ROOM WALL ROOF PLAN - HVAC SCALE: 1/4 = 1--0" SCALE 1/4 = 1 • INDOOR Aft HANDLING FAIT BASIS OF LOCATION AREA SERVED DESIGN SERVER ROOM MTTSU BASH I PK 151( FIRST FLOOR PLAN - HVAC BLACK BOX TI SOUTHCENTER 111 . 11 )1, Hermanson No. pate By Description Drawn 200 ANDOVER PARK E. TUKWILA WA. 98188 I EXPIRES 1/29/06 10/20/04 DN PERMIT SET Design Team DN Checked DN AS NOTED Drawing Number C- 0024 -106 Project Number 10 -4 -106 Issue Date 110/20/04 FIRST FLOOR PLAN, ROOF PLAN & SCHEDULES HVAC IAN OA CPA S.P. IN. W.G. 0 NA ELEC HEATER CAP. IN WATTS DT3 - 100 (TYP . 4) CONNECT 1/2" NG TO EXISTING PIPINNG ON ROOF 1\1 0 Last Updated: 10/14/04 WEIGHT IN POUNDS , REMARKS 53 1,2 0 I • L •11i41 /"- - r • • 1 FIELD VERiY FINAL LOCATION WITH EXISTING STRUCTURE • • RTU -1 J ..... .. . . J. . ...jam � .. Y l 1.� • • • REVIEWED FOR CODE C�MPUANC,E POP Al IMO NOY 17 2004 City Of Tukwila _BUILDING DIVISION CrrY AUG ISSUE FOR PERMIT AEC CITY pF OCT 2 PERMIT Pim* , **cam 104-108 Slade Box SedloodeotVadkEnOtoolneloonclIM2 01 dog. LavivM1. *M1 1 1 WS PAM. iwsi •S PACKAGED ROOFTOP AC UNIT SCHEDULE . . T PAT 1 lAS UPDATED: ED 10/ 3/04 UNIT TAG LOCATION AREA SERVED BASIS OF DESIGN J T. AIR TEMPERATURE , TONNAGE I CR1 , ' MIN. OA. CFM E.S.P IN. WG. I SEER/EER COOLING CAPACITY N. G. HEATING CAP. MBH OUTDOOR FAN INDOOR FAN ELECTRICAL WEIGHT IN POUNDS REMARKS OMB. DEG. F DB. DEG. F WB. DEG. F TOTAL BTUH .SENS. BTUH , STAGES I INPUT OUTPUT TYPE DRIVE RPM HP TYPE I DRIVE RPM ' HP MCA I MCB ' V /PH RTU -1 ROOF ENTIRE TI _ TRANE YSCO36A4 _ 95.0 78.0 64.0 3.0 1,200 400 _ 0.80 10.70 36,000 _ 30,600 _ 1 60 48 , PROP _ DIRECT , 1,075 1/5 CENTR. 1 BELT 1 935 1.0 _ 9.2 _ 15 _ 460/3 664 1 -5 1 2 3 4 5 1 STANDARD BRmSH WHITE FINISH 2 SEE DWG FOR THROW PATTERN DESIRED 3 RUN OW SIZE SAME SIZE AS DIFFUSER NECK SCE, II,N.O. 014 OWGS 4 FILTER GRILLE TO BE PROVIDED WITH INTEGRAL FILTER SYMBOL CU-1 X PROVIDE FULL ECONOMIZER CYCLE AND BAROMETRIC RELIEF MINIMUM UNIT EFFICIENCY TO MEET THE WASHINGTON STATE ENERGY CODE TABLE 14 -1 SUPPLY SIDE SMOKE DETECTOR FURNISHED BY MECHANICAL AND INSTALLED BY ELECTRRCAL CONTRACTOR PROVIDE DISPOSABLE FILTERS AND ROOF CURB ADAPTER PROVIDE 24 HOUR PROGAMMABLE STAID -ALONE THERMOSTAT - HONEYWELL T7300 AREA SERVED SERVER ROOM ISIS Of DESIGN MITSUBISHI PU18EK 1. SPLIT SYST(M UNITS REQUIRE DISCONNECT AT THE ROOF CONDENSING (Ni (RY ELECTRIC A. CONTRACTOR) 2. PROVIDE WITH WIRELESS T"STAT, REFRIGERANT CUES ET MC, CONDENSATE PIMP •@rdAW1W' �.el���y„t.lrw• t� raw, w .Sr 'i 3/8" LIO & 5/8" SUCT REFER LINES DN TO FCU -1 IN SERVER RJOM OIADOOR UNIT REO OOOLMG CAP IN STUN TOTAL SENS. 18,000 • E G0M1 MOUNT UNIT ON SLEEPERS (C i - I FCLI- MIT @ 72" AFF. PUMP CONDENSATE © 3/4" TO NEAREST SINK TAIL PIECE I, 4 1 1 1 3/8" LIQ & 5/8 SUCT REFER LINES UP TO CU-1 ON ROOF 0 s HEATING CAP ELEC V 2 PH SPLIT SYSTEM UNIT SCHEDULE MCA 16 WEIGHT IN POUNDS 54 NM/ ROOM WALL ROOF PLAN - HVAC SCALE: 1/4 = 1--0" SCALE 1/4 = 1 • INDOOR Aft HANDLING FAIT BASIS OF LOCATION AREA SERVED DESIGN SERVER ROOM MTTSU BASH I PK 151( FIRST FLOOR PLAN - HVAC BLACK BOX TI SOUTHCENTER 111 . 11 )1, Hermanson No. pate By Description Drawn 200 ANDOVER PARK E. TUKWILA WA. 98188 I EXPIRES 1/29/06 10/20/04 DN PERMIT SET Design Team DN Checked DN AS NOTED Drawing Number C- 0024 -106 Project Number 10 -4 -106 Issue Date 110/20/04 FIRST FLOOR PLAN, ROOF PLAN & SCHEDULES HVAC IAN OA CPA S.P. IN. W.G. 0 NA ELEC HEATER CAP. IN WATTS DT3 - 100 (TYP . 4) CONNECT 1/2" NG TO EXISTING PIPINNG ON ROOF 1\1 0 Last Updated: 10/14/04 WEIGHT IN POUNDS , REMARKS 53 1,2 0 I • L •11i41 /"- - r • • 1 FIELD VERiY FINAL LOCATION WITH EXISTING STRUCTURE • • RTU -1 J ..... .. . . J. . ...jam � .. Y l 1.� • • • REVIEWED FOR CODE C�MPUANC,E POP Al IMO NOY 17 2004 City Of Tukwila _BUILDING DIVISION CrrY AUG ISSUE FOR PERMIT AEC CITY pF OCT 2 PERMIT Pim* , **cam 104-108 Slade Box SedloodeotVadkEnOtoolneloonclIM2 01 dog. LavivM1. *M1 1 1 WS PAM. iwsi •S