Loading...
HomeMy WebLinkAboutPermit M04-189 - KING COUNTY METROKING COUNTY METRO 11 EAST MARGINAL WY Parcel No.: Address: Suite No: City oar Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us MECHANICAL PERMIT 1023049066 11911 EAST MARGINAL WY S TUKW Permit Number: Issue Date: Permit Expires On: Steve Lancaster; Director M04 -189 11/16/2004 05/15/2005 Tenant: Name: Address: Owner: Name: Address: KING COUNTY METRO 11911 EAST MARGINAL WY S, TUKWILA WA KING COUNTY 500 4TH AVE #500, SEATTLE WA Contact Person: Name: DANIEL LAMBERT Address: PO BOX 220, EAST OLYMPIA WA Contractor: Name: BLUE MOUNTAIN MECH INC Address: PO BOX 220, EAST OLYMPIA WA Contractor License No: BLUEMMI996KU Phone: Phone: 360- 239 -0371 Phone: Expiration Date: 12/30 /2005 DESCRIPTION OF WORK: REMOVING 2 EACH ROOF TOP HEAT PUMPS AND REPLACE WITH EACH 1 EACH CHILLER - VARIOUS PIPE REVISIONS. Value of Mechanical: 184,295.00 Type of Fire Protection: Fees Collected: $1,791.94 International Mechanical Code Edition: 2003 EQUIPMENT TYPE AND QUANTITY Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial 0 0 0 0 0 1 1 0 0 0 0 0 0 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 1 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment0 * *continued on next page ** doe: IMC- Permit M04 -189 Printed: 11 -16 -2004 MCS MICRO COM SYSTEMS LTD. ATTENTION The next image may be a duplicate of the previous image. Please disregard previous image. Please disregard previous 2 images. Please disregard previous 3 images. Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: doe: IMC- Permit City a Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Parcel No.: 1023049066 Address: 11911 EAST MARGINAL WY S TUKW Suite No: KING COUNTY METRO 11911 EAST MARGINAL WY S, TUKWILA WA KING COUNTY 500 4TH AVE #500, SEATTLE WA DESCRIPTION OF WORK: REMOVING 2 EACH ROOF TOP HEAT PUMPS AND REPLACE WITH EACH 1 EACH CHILLER - VARIOUS PIPE REVISIONS. Value of Mechanical: 184,295.00 Type of Fire Protection: DANIEL LAMBERT PO BOX 220, EAST OLYMPIA WA Contractor: Name: BLUE MOUNTAIN MECH INC Address: PO BOX 220, EAST OLYMPIA WA Contractor License No: BLUEMMI996KU Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 1 1 0 0 0 0 0 0 0 * *continued on next page ** M04 -189 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360- 239 -0371 Phone: Expiration Date: 12/30/2005 Steven M. Mullet, Mayor Steve Lancaster, Director M04 -189 11/16/2004 05/15/2005 Fees Collected: $1,791.94 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 1 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 11 -16 -2004 I hereby certify that I have ordinances governing this The granting of this permit regulating constr ction or t Signature: Print N doc: IMC- Permit City oY :Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Name: k M04 -189 fl Permit Number: Issue Date: Permit Expires On: Steven M. Mullet, Mayor Steve Lancaster, Director M04 -189 11/16/2004 05/15/2005 Date: ////6./O Permit Center Authorized Signature: .�i'YC(,�,l�r� l�r /s��✓K v read and examined this permit and know the same to be true and correct. All provisions of law and work will be complied with, whether specified herein or not. does not presume to give authority to violate or cancel the provisions of any other state or local laws anc of work. I am authorized to sign and obtain this mechanical permit. , / r / Date: / '40 (/ 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 11 -16 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049066 Permit Number: M04 -189 Address: 11911 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 10/27/2004 Tenant: KING COUNTY METRO Issue Date: 11/16/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: ** *SPRINKLER SYSTEMS * ** - IFC Chapter 9 - NFPA 13 and 25 11: All new srpinkler sysetms and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 12: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 13: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1900 - NFPA 72 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) doc: Conditions M04 -189 Printed: 11 -16 -2004 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 15: Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #2051) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** M04 -189 Printed: 11 -16 -2004 Th City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or regulating construction or the performance of work. Signature: J �! Print Name: doc: Conditions M04 -189 as outlined. All provisions of law and ordinances cancel the provision of any other work or local laws Date: / b /-14Q D y Printed: 11 -16 -2004 CITY OF TUKWILA Community Developmer, epartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: / / 9 / Tenant Name: iL )--/GG t Property Owners Name: King Co Assessor's Tax No.: ��tS7 A /.44Ae . Lx- 1 Sr Suite Number: 6D. 01 F17 • • Mailing Address: / / / / 37 /"/1724 t Azt. w y (--d09 City State Name: Dig-ph Day Telephone: 360 , e 7 0 3 7 Mailing Address: e0. 3c' . x2020 &_�9s7 0Lys "P9 14.. 6 I ftfct ,,pp City State Zip E -Mail Address: L &-U) /44 TIM 6C%H ( C .n e4sT . /16- - Fax Number: 360 GENERAL CONTRACTOR INFORMATION (Mechanical Contractorr information on back page) Company Name: Mailing Address: fa. ox . , a. •..e.- c 9�s� Company Name: Mailing Address: Contact Person: f � ( 1 - ^-ge-- it Contact Person: E -Mail Address: City E -Mail Address: b L L IJg v t T /4-64 t C t- 4 ; -✓> Fax Number: 360 I/J P -0/ // Contractor Registration Number: 3 L U�/ii v�,r, 96,C U Expiration Date: /2/3/4t/ b'/ * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Contact Person: 1 v(I(il2 E -Mail Address: Fax Number: \permits ptus\icc chanyes\permit application (7.2004) r/4 AF�j oP Page 1 Building PenT'No. Mechanical Permit No. M Public. Works Permit No. Project No. (For office use only) Floor: New Tenant: ❑ .... Yes g..No Zip State Zip Day Telephone: 36o 2J 9 03 7/ State ?T- i6f60- X9"770.,/ Zip City Day Telephone: Fax Number: Mailing Address: City State Zip Day Telephone: 2 -06 8y /74E?/ BUILDING: PERMIT INFORMS SON - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes 0.. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0.. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes ❑ ..No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. %permits plus'icc changcs\parmit application (7 -2004) Page 2 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type. of Occupancy per IBC 1" Floor 2n Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING: PERMIT INFORMS SON - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes 0.. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0.. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes ❑ ..No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. %permits plus'icc changcs\parmit application (7 -2004) Page 2 PUBLIC WORKS PERMIT IN} oRMATION - 206- 433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila 0... Water District #I25 ❑ ...Water Availability Provided Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public *tams plwtice changatpernit application (7.2004) Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line WO# WO# WO# Private Private ❑ .. Highline ❑ .. Work in Flood Zone ❑ .. Storm Drainage Page 3 ❑ ...Renton Sewer District • ❑ ...Tukwila 0... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. ❑ .. Geotechnical Report ❑...TrafTc Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billin Name: Mailing Address: Number of Public Fire Hydrant(s) Day Telephone: City State • Zip Day Telephone: City State Zip Unit. Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>I00K BTU Evaporator Cooler I Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFO1 ':ATION — 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: S-17 I — A'S —I aerit— Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ /g 7 O? 9J Scope of Work (please provide detailed information): i �+^-I ov / i Use: Residential: New ....❑ Replacement ❑ Commercial: New .... ❑ Replacement 9— r . ! CfiLL — v c>v 0 1° -J( Sro, -iS Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING • R O' = �, D ' ENT: Signature: Print Name: DA-4 t - Mailing Address: pd.). 3c x ZZo \permits plus\icc changa \permit application (7 -2004) Page 4 Date: / o C ro Day Telephone: 360 Z3 03 7 / CL V k1 Pr r4 )4- 0,3" o City State Zip Date Application Accepted: i1 - 21o y Date Application Expires: S itials: Payee: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 BLUE MOUNTAIN TRANSACTION LIST: Type Method Description Payment Check 3239 MECHANICAL - NONRES RECEIPT Parcel No.: 1023049066 Permit Number: M04 -189 Address: 11911 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 10/27/2004 Applicant: KING COUNTY METRO Issue Date: Receipt No.: R04 -01538 Payment Amount: 1,415.55 Initials: LAW Payment Date: 11/16/2004 01:57 PM User ID: 1630 Balance: $0.00 ACCOUNT ITEM LIST: Description Account Code Amount 1,415.55 Current Pmts 000/322.100 1,415.55 Total: 1,415.55 7020 11/17 1716 TOTAL 1 41'5.7: Printed: 11 -16 -2004 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: City of Tukwila TRANSACTION LIST: Type Method doc: Receipt 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 1023049066 11911 EAST MARGINAL WY S TUKW KING COUNTY METRO R04 -01462 BLH ADMIN BLUE MOUNTAIN MECHANICAL INC Payment Check Description 3173 PLAN CHECK - NONRES 000/345.830 RECEIPT ACCOUNT ITEM LIST: Description Account Code Permit Number: Status: Applied Date: Issue Date: M04 -189 PENDING 10/27/2004 Payment Amount: 346.39 Payment Date: 10/27/2004 12:20 PM Balance: $1,415.55 Amount 346.39 Current Pmts 346.39 Total: 346.39 • ,40 1 0/20 9 716 TOTAL, 346.39 Printed: 10 -27 -2004 Prrc t Type of Inspn� � c. -' r A\\i s [ / Date Called: 3 (`- Scfa In structions: !/ t /�� �� J ( ��, �, /' /J� _ Date Wanted: 1 1 4 1 1 ID .m. . Requester: c` \ � l �"� Phone No: 1 O . 0 - 2 _3R - 0311 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION ' ���'j" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 206)431 -3670 CO11 ENTS: • Approved per applicable codes. El Corrections required prior to approval. $58. EINSPECTIO REQUIR D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: COMMENTS: (�, 1 •) Et��1rt \ ha+' Gl r Min, I t h 2-) , - :)() Y\(7 6`\e' v RP f- -`✓∎ . ✓rh4 _U S. \1011'P� V" oovv. n,r iO l -P r V O w1 Special Instructions: }We 7...2a v\ i vr( • 3.) � rr j ( p ,P , h-'-Pr 11 5 S4fAWI - Od 11 a.m. p.m. r , 1 p Q V rn/ak 44/ v- a keArigli +1 `'p c o in , r (, `b r U r� � (W' rno r- Phone No: Proje t• —( r l r OuV\A - • ' 'e' f ✓G Type of Inspection: , �l' I< Addr \\ . G� LA)-7 Date Called: _U S. Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: VI)q 1 g INSPECTION NO. PERM' NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431=36 El Approved per applicable codes. !Inspector: x. INSPECTION RECORD Retain a copy with permit C orrections required prior to approval. Date: 1 1 1' 0 5 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: Date: Proji5t : I vi Ca. � M r0 Type of Inspection: f S p cta� wPld:h , Date Callet: . ) l Address: t V � lei 6) Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD , Retain a copy with permit 9 INSPECT( N NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43'1`' 6-7b a ' Approved per applicable codes. El Corrections required prior to approval. COMMENTS: C'P \Nrrnl j lnspector( Date: L_ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: Date: Project,: I �c C(i � L Type of c on: C4PCLf F41 c.\ Address: I \\�1 \ E . Al Date Called: I hi- Uc Special Instructions: Date Wanted: a.m. p.m• Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. INSPECTION RECORD r � o � ` Retain a copy with permit PERMIT El Corrections required prior to approval. COMMENTS: 'WA 1 r \At f ti \ 5--Vi text i' rA �/1 r1" --N( G ( u) «,r Inspector: Z.,„4 Date: \ )4 O El $47.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: !Date: Project: Ki MA C OUnt Mefro Type of Inspection: -- -,g, . Addres It 911E Marginal Wv S Date Called: /-3 -O Special Instructions: 131 "" Date Wanted: a , : p.m. Requester: Dqn /- v ibr# Phone No: ?6 23 q_ 0311 Inspector:' INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 }>L NO I8 ? PERMIT NO. Date: if C) S 'pproved per applicable codes. , El Corrections required prior to approval. COMMENTS: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pct : (jYn /,v / Type o nspection: , 111 Add ( ' 1 , 60 ' Date ailed: I ( '( 3' .. ( /0 Sp cial structions: _, ` ::r e ) a`7 PQ c q • Q U `� S"� r . ' 1 1 I+Q , ;Av, Pho DUO) �q 03 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Inspecto DD p roved appliOble codes: Corrections required prior to approval. COMMENTS: � �a r - 1 1 a Ax pi Ar W„p rLIA t:t 1 CPU( t 1M r rUv i �� Qe covet( mot4er)ec:t c ivA vw -P -(-- ,w■ ` 4r) co ± , " 1.2 I,. El ;47.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: mifr Date: tit �. z t—i LU p � O Ns 431—, WW O, Z U N ,, -Z Proj, \ i Type Inspection dres : /IV/ , Date ailed: pedal Instructions: 5, Date Wanted: /._, -9- C Request5 Phonja-No: (.?0 )4?...F7 .3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 111 Approved per applicable codes. • INSPECTION RECORD Retain a copy with permit ••• (206)431-3670 Ei Corrections required prior to approval. COMMENTS: 407 6 < Ei $47. REINSPECTIO FEE REQUIRED. Prior to inspection, fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: Date: t . .4 777- .: 77 '7"" J7. • .1 7, 7 1;7 7 70 ,1 " 7 ., • 4 9 , 5 ,,, V ,11 7 47 W ,7 4 713 XF 74 1 , ,,,rA: 11 1 v vrq" : "" : 77 — c :: lo V C vl 7 / :,.:.:. ..::. . i Address I /0/ / I Er_ •, vo r,,- / 1A-9 t-e* S Suite # , : , ." ,Retaincurrent inspection schedule .:. . . , . •, 'Need shift inspection City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas P Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM t Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: 4k — Authorized Signature FINALAPP.FRM Rev. 2/19/98 Permit No. 1 Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 re Li 6 ...i 0 cn w tu 0 g i I— u " 4E i-0 Z F— LU uj 2 D p co — 0 F— LU u j Z LU CO = I = J- O I- z PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M04 -189 DATE: 10 -27 -04 PROJECT NAME: KING COUNTY METRO SITE ADDRESS: 11911 EAST MARGINAL WAY SOUTH Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision #_after /before permit is issued DEPARTMENTS: II ii Nw� r0 Buildivislon Public Works ❑ Documents /routing slIp,doc 2-28-02 5/0 AWti I I- S'U . Fire Prevention ❑ Structural ❑ Complete Incomplete ❑ Planning Division Permit Coordinator DETERMINA ON OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -28 -04 REVIEWER'S INITIALS: PERMIT COORD COPY Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROJJTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -25 -04 Approved ❑ Approved with Conditions N ot Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: King County Department of Transportation Transit Division, Design and Construction Section 11911 E. Marginal Way South, Building B • Tukwila, WA 98168 -5199 • (206) 684 -2893 • Fax (206) 684 -2284 December 20, 2004 C33143C -04 Mr. Bill Rambo City of Tukwila, Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188 -2544 South Facilities HVAC Replacement King County Contract C33143C Letter of Certification for the use of Type L Hard Tempered Copper Tubing, ASTM B88 Dear Mr. Rambo: The purpose of this letter is to provide the City of Tukwila with written certification that King County accepts responsibility for the use of Type L hard tempered copper tubing and wrought copper fittings. The use of type L copper tubing and fittings for heating hot water and chilled water piping will conform to King County Specifications 15140 2.02 -C, 3.03, 3.04 and 3.06. If you have any questions concerning this letter of certification or other items, please contact me at (206) 263 -4504. Very truly yours, Jeffrey P. Turner, P.E. Project Engineer cc: Jerry Williams, SCS -TR -0100 File PiFCEIMc. Teel, SCS -TR -0100 - 4 L005 BUILDING LiEP ARTMENT 1101-1- 199 • f Krazan & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • E CONSTRUCTION TEST December 15, 2004 Jerry Williams KING COUNTY 201 South Jackson, M/S KCS —TR -0435 Seattle, Washington 98104 RE: Construction Testing and Inspection South Facility HVAC — Building C 11911 East Marginal Way South Tukwila, Washington RM/ga Ryman Mercer Project Manager Pacific Northwest Division ECEOVE DEC: 2 i 2004 CONSTRUCTION DIVISION SOUTH SATELLITE OFFIrr• D 1NA INEERING KA No. 096 -04328 Permit No. C33143C Dear Mr, Williams, In accordance with your request and authorization, our firm performed construction testing and inspection for the above- referenced project. The inspections were performed by our inspectors from December 3, 2004. The following reports are attached: • Report 2362 dated December 3, 2004 If you have any questions or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN & ASSOCI TES, INC. Offices Serving The Western United States 19501— 144` Avenue NE # F -300 • Woodinville, Washington 98072 • (425) 485 -5519 • Fax (425) 485 -6837 09604328 drr 1409 -189 RECEIVED JAN -4 2005 DEPARTMENT 4 . dKrazan DATE: PROJECT #: PROJECT: LOCATION: KRAZAN PROJECT MANAGER: GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION & Associates, Inc. CONTRACTOR: PERMIT NO INSPECTOR: JURISDICTION: WEATHER: WELDING REPORT NO.: K INS Ck-uI 3 C EY (N UKW tLA I D1'� 236 TEMP: Ptr18kc N Zid FIELD ❑ SHOP WELDING ❑ M.T. ❑ P. T. ,1*0 V.T. Item(s) inspected. 1 1 J► \� ' t w aiIammi Z Position: ❑ Process: ❑ Weld Type: ❑ Weld Size ¥Codes: SMAW FILLET 3/16" VER FCAW C.P. 1/4" AISC I HORI ONTALJ GMAW P.P. 5/16" TITLE 21 OVERHEAD SAW PLUG 3/8" TITLE 24 ❑ Filler Metal: ❑ Other: ❑ Other V . Other: UBC 8 %' F . ASME To the best of my knowledge, the abo Superintendent/Representative: 215 West Dakota Ave., Clovis, CA 93612 2205 Coy Ave., Bakersfield, CA 93307 1025 Lone Palm Ave. #2E, Modesto, CA 95351 545 Parrott St., San Jose, CA 95112 5808 Price Ave. Bldg. 1016, McClellan, CA 95652 WAS NOT performed in accordance with the approved pl s, specifications, d regulasory requirements. • • • • • (559) 348-2200 (661) 837-9200 (209) 572-2200 (408) 271 -2200 (916) 564-2200 Technician: 4221 Brickell St., Ontario, CA 91761 1501-15' St. NW Suite 106, Auburn, WA 98002 20714 State Hwy 305 NE Suite 3C, Poulsbo, WA 98370 19501.144" Avo. NE #F-300, Woodinville, WA 98072 ROUTH SATELLITE OFFICE" • • • • (909) 974-4400 (253) 939 -2500 (360) 598-2126 (425) 485-5519 0 (L!fI\Y/[ E 7 ,1 DEC 2. 1 2UO4 J1 4 . dKrazan DATE: PROJECT #: PROJECT: LOCATION: KRAZAN PROJECT MANAGER: GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION & Associates, Inc. CONTRACTOR: PERMIT NO INSPECTOR: JURISDICTION: WEATHER: WELDING REPORT NO.: K INS Ck-uI 3 C EY (N UKW tLA I D1'� 236 TEMP: Ptr18kc N Zid FIELD ❑ SHOP WELDING ❑ M.T. ❑ P. T. ,1*0 V.T. Item(s) inspected. 1 1 J► \� ' t w aiIammi Z Position: ❑ Process: ❑ Weld Type: ❑ Weld Size ¥Codes: SMAW FILLET 3/16" VER FCAW C.P. 1/4" AISC I HORI ONTALJ GMAW P.P. 5/16" TITLE 21 OVERHEAD SAW PLUG 3/8" TITLE 24 ❑ Filler Metal: ❑ Other: ❑ Other V . Other: UBC 8 %' F . ASME To the best of my knowledge, the abo Superintendent/Representative: 215 West Dakota Ave., Clovis, CA 93612 2205 Coy Ave., Bakersfield, CA 93307 1025 Lone Palm Ave. #2E, Modesto, CA 95351 545 Parrott St., San Jose, CA 95112 5808 Price Ave. Bldg. 1016, McClellan, CA 95652 WAS NOT performed in accordance with the approved pl s, specifications, d regulasory requirements. • • • • • (559) 348-2200 (661) 837-9200 (209) 572-2200 (408) 271 -2200 (916) 564-2200 Technician: 4221 Brickell St., Ontario, CA 91761 1501-15' St. NW Suite 106, Auburn, WA 98002 20714 State Hwy 305 NE Suite 3C, Poulsbo, WA 98370 19501.144" Avo. NE #F-300, Woodinville, WA 98072 ROUTH SATELLITE OFFICE" • • • • (909) 974-4400 (253) 939 -2500 (360) 598-2126 (425) 485-5519 • -L,Qtge-2 \-Qoe ICAkijirrA)' _001111111 % v i ff OIX 04 1,_ .1* 1 0"' —1 0% • '' 171AS \ fq . ? cd ,;, .. 0 .• e . = AP\ ctvyv v_mb slime% opsztyvaa Acidsm puv qpriau • (L61) 00O1 • . . • . . • . • .." 0 VS 8 6- . • iiM . IIICIK4 .I.SXa 0 Z Z ..xos.cia • DNI 1.104Di Nil/111110N SIYIS . . . I Q O.Z / I E / S 0 . . . &WU sA.r...oaa•aa - :50.0Z/9E/Z-C fp1866I14142fi! . . :.IODD . iota •axa':..• •;:#..•Isioaa...;': ....._ ... •• •• ...... 1 sv mvi is azaihtyaa sv . . • .. .. . . rniasbig6 „mop iTastio3 l' ,,...„....-_,......_,. --.....:., , .........,.._____ _ • 8gISISfl?1■11 Q in £0/1. 30 ,11■I1KillVd1G • __ -_,.... .,............,:— -...,.....,--..............,...........,....,..........„,..........- .,....- NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR IHAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. . 2 0 c r c .)2 o c co 0 JCD 0 en I I r 0 iN . (D ( •Q I: U) r r J 0 i • • x u c 0 C r 0 Q • c i • r () • F SOUTH BASE WEST O VICINITY MAP KING COUNTY PIERCE COUNTY TYPICAL SECTION AND DETAIL REFERENCING SYSTEM SOUTH BASE -- WEST CONTRACTOR STAGING AREA 1 191 1 E MARGINAL WAY S TUKWILA, WA 98168 S 124TH ST S 116TH ST SOUTH BASE LOCATION MAP 0 200 400 600 I- a) S 117TH ST S 119TH ST S 116TH ST S 122ND ST R NICHOLS DRAWN: R NICHOLS CHECKED: r J TURNER ONE INCH AT FULL SIZE 1' IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: (1) THE SECTION IS CUT ON DRAWING A101 SECTION NUMBER ELEVATION NUMBER (2) ON DRAWING A105 THIS SECTION IS IDENTIFIED SECTION NUMBER SECTION SCALE: 1 1/2"= 1 ' -0" A105 2/A103 MOUNTLAKE O TERRACE SNOHOMISH KING 0 DRAWING ON WHICH SECTION /ELEVATION APPEARS. - INDICATES THE DRAWING IS ON THE SAME SHEET. DRAWING ON WHICH SECTION WAS TAKEN. - INDICATES THE DRAWING IS TAKEN FROM THE SAME SHEET. (3) DETAILS ARE CROSS- REFERENCED IN A SIMILAR MANNER, EXCEPT THAT DETAILS ARE IDENTIFIED BY LETTER RATHER THAN BY NUMBER. S 115TH ST .�. Pion rain* approval is subject to errors and ombitor. Approval of construction documents does not authorize the vbIation of any adopted code or ordinance. Receipt d approved Field 0ag 4, dm/ ny Oty of TUlcwila WILDING DIVISION - i. No changes doll be mode to the expo wort[ iieithol* prior approval Of Tukwila Building Division. NOTE: Revisions wd! require a new pin sib bnittai and may Include additional plan review fees. I NINE' REQUIRED Mb o Mechstiad of Metrical � cy. wv�no City Of BUILDING DIMON '7 c4 I EXPIRES > > /e/ 5 1 grown 14/r PERMIT MO APPlOft AMMO RECOMMENDED: 0 CRIPPEN SHEET INDEX DRAWING SHEET NUMBER 1 G0.01 2 G0.02 3 G0.03 4 A5.01 5 A5.02 6 M1.01 7 M1.02 8 M1.03 9 M1.04 10 M1.05 11 M4.01 12 M4.02 13 M4.03 14 M4.04 .15 M4.05 16 M4.06 17 . , M5.01 18 . • M5.02 19 M6.01 20 M6.02 21 M6.03 22 M6.04 l2 3 E1.01 4 E 1 .02 5 E1.03 6 • E5.01 7 E6.01 NOTES: CONTRACT No: C33143C . a DESCRIPTION VICINITY & LOCATION MAPS & DRAWING LEGEND & ABBREVIATIONS COMPOSITE FLOOR & ROOF PLANS SECTIONS AND DETAILS SECTIONS AND DETAILS FIRST FLOOR SECTOR A PIPING FIRST FLOOR SECTOR B PIPING ROOF PLAN SECTOR A DEMOLITION ROOF PLAN SECTOR A ROOF PLAN SECTOR B FIRE PROTECTION MECHANICAL ROOM DEMOLITION MECHANICAL ROOM INSTALLATION FIRST FLOOR SECTOR A HVAC FIRST FLOOR SECTOR B HVAC MECHANICAL ROOM PLANS & SECTIONS PARTIAL PLANS & SECTIONS MECHANICAL DETAILS . PIPING DIAGRAM REMOVAL PIPING DIAGRAM INSTALLATION CONTROL DIAGRAM EQUIPMENT SCHEDULES MEZZANINE FLOOR PLAN FIRST FLOOR PLAN ROOF PLAN ELECTRICAL DETAILS SCHEDULES it c4l. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 41 � op ' E AND THE LATEST EDITION OF THE TUKWILA BUILDING CODE. OF THE TUKWILA BUILDING IT 1S THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL BUILDING UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID HARM TO ANY OTHER BUILDING UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. 3. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS REQUIRED TO PROTECT EXISTING BUILDING UTILITIES, EQUIPMENT OR BUILT -IN FURNISHINGS REMAINING IN THE WORK AREA DURING CONSTRUCTION. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LOCATIONS PRIOR TO START OF WORK. AS NOTED • .- ........IN King County Department of Transportation SHEET INDEX ■ ,.. SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT KING COUNTY CONTRACT N0. C33143C t METRO TRANSIT DIVISION SOUTH BASE -WEST SOUTH FACILITIES HVAC UPGRADE PROJECT VICINITY 8c LOCATION MAPS Sc DRAWING SHEET INDEX f C RECEIVED TUKWILA OCT 2 T 2004 PERMIT CSR I DATE: JAN 2004 YANG Na 60.01 SHEET NO OF 1 ')7 ...•..•.•••1■ •.......« .. - .... 11110•1••.••/ M04 -189 • %AO '1 • ABBREVIATIONS A, AMP AFF AHU AS AWG BHP BTU GOD BOP CA CC CFM COP CHLR CHS CHR CMU COL CS Cv CW DIA ON DPV (E) EA EAT EER EMT ESP ETK EWT FT GA GALV GFCI GPM GRS H HC HP HP/CHLR HW HWR HWC HWS HZ IN KW LAT LBS LWT MAX MBH MCC MHP MIN MU (N) NG NO OA OC PD PH POC PSIG REF REVD RPM SO FT TDH TEMP TSP TTE TYP UH V WG AMPERE ABOVE FINISHED FLOOR AIR HANDLING UNIT AIR SEPARATOR AMERICAN WIRE GAUGE BRAKE HORSE POWER BRI7ISH THERMAL UNIT BOTTOM OF DUCT BOTTOM OF PIPE COMPRESSED AIR COOLING COIL CUBIC FEET PER MINUTE COEFFICIENT OF PERFORMANCE CHILLER CHILLED WATER SUPPLY CHILLED WATER RETURN CONCRETE MASONARY UNIT COLUMN CHEMICAL SUPPLY FLOW COEFFICIENT COLD WATER DIAMETER DOWN DIFFERENTIAL PRESSURE VALVE EXISTING EACH ENTERING AIR TEMPERATURE ENERGY EFFICIENCY RATIO ELECTRICAL METALLIC TUBING EXTERNAL STATIC PRESSURE EXPANSION TANK ENTERING WATER TEMPERATURE DEGREES FAHRENHEIT FEET GAUGE GALVANIZED GROUND FAULT CIRCUIT INTERRUPTING GALLONS PER MINUTE GALVANIZED RIGID STEEL HEIGHT HEATING COIL HORSEPOWER HEAT PUMP/CHILLER HOT WATER HOT WATER RETURN HOT WATER CIRCULATING HOT WATER SUPPLY HERTZ INCHES KILOWATT LEAVING AIR TEMPERATURE POUNDS LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU MOTOR CONTROL CENTER MOTOR HORSE POWER MINIMUM MAKEUP WATER NEW NATURAL GAS NUMBER OUTSIDE AIR ON CENTER PRESSURE DROP PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH (GUAGE) REFERENCE REQUIRED REVOLUTIONS PER MINUTE SQUARE FEET TOTAL DYNAMIC HEAD TEMPERATURE TOTAL STATIC PRESSURE TEMPERATURE TRANSMITTER ELEMENT TYPICAL UNIT HEATER VOLTS WATT WATER GAUGE REVISION BY APP*0 DATE MECHANICAL SYMBOLS 411•11■11•11Mffia .■■■•■•■••C VD Le BALL VALVE (NORMALLY OPEN) BALL VALVE (NORMALLY CLOSED) GATE VALVE (NORMALLY OPEN) GATE VALVE (NORMALLY CLOSED) FLOW CONTROL VALVE GLOBE VALVE SOLENOID VALVE TWO WAY CONTROL VALVE THREE WAY CONTROL VALVE MANUAL AIR VENT PRESSURE GAGE THERMOMETER REDUCER CAP QUICK DISCONNECT CHECK VALVE BALANCING VALVE BUTTERFLY VALVE PRESSURE REGULATING VALVE STRAINER AUTOMATIC AIR VENT PIPE UNION POINT OF CONNECTION 1-11. PRESSURE RELIEF VALVE FIRE DAMPER VOLUME DAMPER DUCTWORK TO BE CLEANED FIRE DAMPER ACCESS PANEL CONTROLS PRESSURE TRANSMITTER PUMP war TEMPERATURE ELEMENT FLEXIBLE CONNECTION •••■■••=.111111111011. (E) 11 _11 . -HWS HWR - CHS -CH R mu - - CS- DIRECTION S - DIRECTION OF FLOW DOWNWARD SLOPE OF PIPE CONNECTION POINT (FROM EXISTING TO NEW PIPING) HOT WATER SUPPLY HOT WATER RETURN CHILLED WATER SUPPLY CHILLED WATER RETURN MAKE UP WATER CHEMICAL SUPPLY REMOVAL C DESIGNED: R NICHOLS DRAIN: R NICHOLS CHECKED: J TURNER RECOMENDEI): 0 CRIPPEN cNTT NO: PROJECT kIPAAGIER: G STRONKS APPROVED: 13 ISLER k MIS NO: 432620 war =um 02T-07 C33143C ELECTRICAL SYMBOLS 0 o 0 I NONE ONE INCH AT FULL SIZE • IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: /51 SWITCH SAFETY DISCONNECT DUPLEX JUNCTION BOX 120Y/208V PANELBOARD 277Y/480V PANELBOARD OVERLOAD HEATER I- NEMA STARTER CIRCUIT BREAKER MOTOR (# = HP) Mug County Department of Transportation mt. • METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT LEGEND I& ABBREVIATIONS RECEIVED crry OF runtflu■ OCT 2 7 2014 PERMIT CENTER DATE: JAN 2004 DRAWING NO: G0.02 SHEET NO: Of 2 27 • • - • --Ai: i.; . t.. UNIT HEATER EXH FLUE UNIT HEATER AND OIL TANK STAIRS TO MEZZANINE STAIRS TO ROOF BOILER ROOM wag Emu WAI I III I DESIGNED: R NICHOLS DRAWN: R NICHOLS CHECKED: J TURNER RECOMMENDED: D CRIPPEN G STRONKS APPROVED: 8 ISLER 7 as NO: 432620 wows NEWEST: 02T-07 CONTRACT NO: C33143C SCALE: NONE ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT COMPOSITE FLOOR & ROOF PLANS DATE: JAN 2004 a GOOF PLAN SCALE: 1/32" = 1' -0" FIRST FLOOR PLAN SCALE: 1 /32" i '-0" • 00 i NEW OA INTAKE AND EXH HOOD I • a . 114 0 I t)9 t RECEIVED CITV OF Kwtu1 OCT 2 72014 PERMIT CENTER DRAWING G0.03 SHEET NO: OF 3 27 L. X REGISTERED AR� J FARJO STATE OF WASHINGTON R NICHOLS G STRONKS APPROVED: B ISLER IBIS NO: 432620 walk wpuEST: 07T -07 CONTRACT Nor C33413C VARIES ONE INCH AT FULL SIZE 1" F NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: EXISTING TRUSS SYSTEM NEW EXHAUST DUCTWORK 1/4" THICK X 2" WIDE NEOPRENE GASKET CONTINUOUSE ON TOP OF CURB. CAPED, GASKETED FASTENERS ( 8" O.C. ) MINIMUM THREE FASTENERS PER SIDE) EXISTING CURBING 0 i v V v w v v v VVVV VVV \/ VVVVVVV i1v vV V VV • DETAIL SCALE: 3 " =1 ' —0" sieS •., VVV VVVV v v� 4 SECTION SCALE: 1 /2"= 1 '-0" / 1 . r A5.01 • (NEW) OUTSIDE AIR INTAKE. REFER TO DRAWING NO. M5.01 FOR DETAILS. SHEET METAL FLASHING RECEIVER GASKETED FASTENERS ( 12" O.C. MINIMUM THREE FASTENERS PER SIDE) GASKETED FASTENERS (12" O.C.) MINIMUM THREE FASTENERS PER SIDE) REMOVABLE SHEET METAL COUNTERFLASHING FLASHING MEMBRANE (ADHERED TO CURB) ROOF MEMBRANE SEALANT at 3' MIN, GYP) ROOF DECK ROOF BALLAST . • v THERMSET ROOF MEMBRANE ' c7 AiSiSe ' VV UP AND OVER NEW CURBING V V V VV V V V V V V V V V V TOP LIP VVVVVVVVV THERMAL INSULATION COPE 2 1/2"X 2 1 /2"X 1/4" STEEL ANGLE COPE TO MATCH EXISTING TRUSS SYSTEM. EXISTING TRUSS SUPPORT • . . . r . • . r . . • . . 'V • . . • . . . TRUSS V V V V Ni 1/8 1 8 DETAIL SCALE: 3"=1' —0" N./ v � v�' °v vv v v vv`r `rv" " °qv e, z V V VVV v vv v VVVVVV V DETAIL SCALE: 3"=1' —0" • A5.01 LAP SEALANT (r M1.03 ROOF MEMBRANE TO MATCH EXISTING NEW INTAKE HOOD WOOD NAILER TO COME WITH CURBING CURBING BY PENN VENTILATOR, OR EQUAL 1 1/2" RIGID POLYISOCYANURATE FILLER #10 SCREWS SPLICE ADHESIVE �► ak .s••trr \di v "Iv 'V 'V 'Vv\ \/ \/ ✓ .J \/ V \/ V V v v \/ 'J '.i 'V 'V \/v\ ii 6" O.C. #10 SCREWS ON 12" O.C. EXISTING INSULATION NEW INSULATION 1/8" CONTINUOUS STEEL PLATE WIDTH AS REQ'D TO SPAN A MINIMUM OF 2 DECK FLUTES PROVIDE A MINIMUM OF 1 "X 1 "X 1 /4" CROSS BLOCKING. COPE FOR WELDING TO MAIN SUPPORT. SEALANT (NP) ∎ ♦ A * ∎ A ∎ • ∎ ** ` ♦ ` & A . • E e tt ♦� + .•. + � ♦ fr I A . . DETAIL SCALE: NONE ROOF PENETRATION BLOCKING. REFER TO DETAIL 8 COPE 2 1/2"X 2 1/2"X 1/4" STEEL ANGLE COPE TO MATCH EXISTING TRUSS SYSTEM. EXISTING TRUSS SUPPORT DUCTING THRU ROOF 24" u M5.01 - BOOT 1/8" CONTINUOUS STEEL PLATE WIDTH AS REQ'D TO SPAN A MINIMUM OF 2 DECK FLUTES SECTION SCALE: HALF METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT SECTIONS & DETAILS SUPPORT BY MECHANICAL CONTRACTOR r .MI., ■•••• en,/ 4........ • « i. , . , .r r .. - • - ROOF DECK • C ar of Tug -- OCT 2 7 2814 PERMIT CENTER A 4 1 8 I = W a No. 12GA. GALVANIZED STEEL CAP REVISION • I III III II pu CRICKET 2X2X1/4 STEEL ANGLE 2' O.C. PARTIAL PLAN SCALE: 3/4 "= 1' -0" BY APP'D DATE II SHEET METAL FLASHING RECEIVER HIGH - DOMED, CAPED, GASKETED FASTENERS ( 12" O.C. ) MINIMUM THREE FASTENERS PER SIDE) REMOVABLE SHEET METAL COUNTERFLASHING FLASHING MEMBRANE (ADHERED TO CURB) ROOF MEMBRANE SEALANT #10 SCREW 0 12" O.C. (MIN.) #10 SCREWS 0 6" O.C. ROOF THERMAL INSULATION NEW STRUCTURAL SUPPORT ANGLES TRUSS SYSTEM NEW CHILLER (SEE MECHANICAL) NEW CURBING EXISTING ROOF SYSTEM NEW STRUCTURAL SUPPORT ANGLES EXISTING TRUSSES V V V V V V V V V V V V V V V V V V V V V VVV V V V V V V V V VV VV N ' 05f.IN5K26522,2216MR2 3140 REGISTERED ARCHITECT a F STATE OF % SHIN CTON DESIGNED: R NICHOLS DRAWN: R NICHOLS CHECKED: Y. FARJO RECOMMENDED D CRIPPEN PROJECT MANAGER: G STRONKS psi APPROVED: B ISLER IBIS NO: 432620 nowt IEOU Esr: 02T-07 CONTRACT NO: C33143C 12GA GALVANIZED STEEL CAP NEW CHILLER HIGH-DOMED, CAPED, GASKETED FASTENERS ( 12" O.C. ) MINIMUM THREE FASTENERS PER SIDE) WOOD NAILER TO COME WITH CURBING PRE - FABRICATED CURBING 1 1/2" RIGID POLYISOCYANURATE FILLER 1/8" CONTINUOUS STEEL PLATE A WIDTH AS REQ'D TO SPAN BETWEEN A MINIMUM OF 2 DECK FLUTES . COPE 2 1/2"X 2 1/2"X 1/4" STEEL ANGLE COPE TO MATCH EXISTING TRUSS SYSTEM. NEW 2 1/2"X 2 1/2 "X 1/4" STEEL ANGLE 2 1/2 "X 2 1/2 "X 1/4" STEEL ANGLE COPE 2 1/2"X 2 1/2"X 1/4" STEEL ANGLE COPE TO MATCH EXISTING TRUSS SYSTEM. EXISTING TRUSS SUPPORT SCALE: AS NOTED ONE INCH AT FULL SIZE I D-1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: #51 SHEET METAL OR FLEX -TUBE COLLAR 2" King County Department of Transportation SHEET METAL FLASHING RECEIVER 2X2X1/4 STEEL ANGLE 04-(8 F THERMSET ROOF MEMBRANE UP AND OVER NEW CURBING TOP LIP SECTIONS & DETAILS METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT • \/ \/ \/v \/vv \,/ vv\d/vvN, /vuuvuuu vvvvv N./ v v v v v U SHEET METAL ENCLOSURE WITH REMOVABLE TOP - CROSSBREAK OR SLOPE FOR DRAINAGE INSULATE VOID TO PREVENT CONDENSATION ROOF DECK CT' OF TUKWILA OCT27 2014 PERMIT CENTER J DATE: JAN 2004 DRAWING NO: A5.02 SHEET NO: OF . 5 27 •■■ ••• . - •M w. r • w.�.r .'.1 ^ p ..�. .. y*. •�.d....� K �r f.yni••••. f ... �i -.'�11 .'�' `��,�h r y� w�..... . -.w. ,,,,.... .•..w■.■■ ....+wW.r - ...�..�.,. ..r �..5:��i+_::.alc.irL::. t ... � i�v/j.�•ail•�i�w. I I I I II r i t II II II II 11 II II Id I M II 1 "1"......."'''''...."*.'''..........1111 4NNNNIN .... \ i I ' 4 1 8 I = W a No. 12GA. GALVANIZED STEEL CAP REVISION • I III III II pu CRICKET 2X2X1/4 STEEL ANGLE 2' O.C. PARTIAL PLAN SCALE: 3/4 "= 1' -0" BY APP'D DATE II SHEET METAL FLASHING RECEIVER HIGH - DOMED, CAPED, GASKETED FASTENERS ( 12" O.C. ) MINIMUM THREE FASTENERS PER SIDE) REMOVABLE SHEET METAL COUNTERFLASHING FLASHING MEMBRANE (ADHERED TO CURB) ROOF MEMBRANE SEALANT #10 SCREW 0 12" O.C. (MIN.) #10 SCREWS 0 6" O.C. ROOF THERMAL INSULATION NEW STRUCTURAL SUPPORT ANGLES TRUSS SYSTEM NEW CHILLER (SEE MECHANICAL) NEW CURBING EXISTING ROOF SYSTEM NEW STRUCTURAL SUPPORT ANGLES EXISTING TRUSSES V V V V V V V V V V V V V V V V V V V V V VVV V V V V V V V V VV VV N ' 05f.IN5K26522,2216MR2 3140 REGISTERED ARCHITECT a F STATE OF % SHIN CTON DESIGNED: R NICHOLS DRAWN: R NICHOLS CHECKED: Y. FARJO RECOMMENDED D CRIPPEN PROJECT MANAGER: G STRONKS psi APPROVED: B ISLER IBIS NO: 432620 nowt IEOU Esr: 02T-07 CONTRACT NO: C33143C 12GA GALVANIZED STEEL CAP NEW CHILLER HIGH-DOMED, CAPED, GASKETED FASTENERS ( 12" O.C. ) MINIMUM THREE FASTENERS PER SIDE) WOOD NAILER TO COME WITH CURBING PRE - FABRICATED CURBING 1 1/2" RIGID POLYISOCYANURATE FILLER 1/8" CONTINUOUS STEEL PLATE A WIDTH AS REQ'D TO SPAN BETWEEN A MINIMUM OF 2 DECK FLUTES . COPE 2 1/2"X 2 1/2"X 1/4" STEEL ANGLE COPE TO MATCH EXISTING TRUSS SYSTEM. NEW 2 1/2"X 2 1/2 "X 1/4" STEEL ANGLE 2 1/2 "X 2 1/2 "X 1/4" STEEL ANGLE COPE 2 1/2"X 2 1/2"X 1/4" STEEL ANGLE COPE TO MATCH EXISTING TRUSS SYSTEM. EXISTING TRUSS SUPPORT SCALE: AS NOTED ONE INCH AT FULL SIZE I D-1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: #51 SHEET METAL OR FLEX -TUBE COLLAR 2" King County Department of Transportation SHEET METAL FLASHING RECEIVER 2X2X1/4 STEEL ANGLE 04-(8 F THERMSET ROOF MEMBRANE UP AND OVER NEW CURBING TOP LIP SECTIONS & DETAILS METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT • \/ \/ \/v \/vv \,/ vv\d/vvN, /vuuvuuu vvvvv N./ v v v v v U SHEET METAL ENCLOSURE WITH REMOVABLE TOP - CROSSBREAK OR SLOPE FOR DRAINAGE INSULATE VOID TO PREVENT CONDENSATION ROOF DECK CT' OF TUKWILA OCT27 2014 PERMIT CENTER J DATE: JAN 2004 DRAWING NO: A5.02 SHEET NO: OF . 5 27 •■■ ••• . - •M w. r • w.�.r .'.1 ^ p ..�. .. y*. •�.d....� K �r f.yni••••. f ... �i -.'�11 .'�' `��,�h r y� w�..... . -.w. ,,,,.... .•..w■.■■ ....+wW.r - ...�..�.,. ..r �..5:��i+_::.alc.irL::. t ... � i�v/j.�•ail•�i�w. :' A14 DN 117 UTaPp DRAIN O" AFF SEE NOTE 3 IUU- t 1 _.. _..1-- -- /Z" A ON GARDEN 5.4OP 11341 1.414k F-4.444. tur.4-1 \ SEE NOTE 3 'au-r I SEE NOTE 3 I 3" P -t2 'VA PO /R/Es i i i ULJ3T COLLECTOR I13eAl w 3° P -11 _._ 1 . A Oit P -7 REVISION 4" p5L DN (-4 ORL DN P-4 P- 16 •4" - HWR- CARPENTER SWOP [IY:21 SEE NOTE 3 Pc- QN -P- 7 ' N 1I�? VTR L yz: A DN ... . Ow ..... • A ._, ORNL ON TRENCH DRA %N(REF) Al -•4. • • 4 1 1 PIPING F3ETWEEN JOISTS 2 CONSTRUCTOR'S 91�- OP )'z'A9J I35 1 2" 1 Y EXPOSED PIPING LAN 10 2 • W AFF (Nero rH stre P -5 Ito I-1W5 , I t,1-4WR tip TO A.1-1U !2 SEE ASSEMBLY BY SEE NTE TE Y2 "A DN — tEt Alak (TYP kr:77T 'Cr AIR DROPS) _.._......�_.. -HWR- ! T I/4 * 2/2. 1 Or' 1� 1A, lit1 •DR►VE;lfNRU i'°I 21/21 1 U 0'331 SEE P - it APP'D DATE P -9 SEE NOTE 3 oif f-PC° M 4 R.L GoiJ P - 14 I4 I ` P Ira � 4 M C7 + Z A ON SEE NOTE 3 I 4 c#41 ASSEMBLY f te 13 0 L o 414111--40.- v T I 1/2" • i I l•• ` Q "VTR, ft"ON SAND/OIL MTERCEPTOR l eee orAles G•5 f"CR Rti,.CcCfr■T i o4 Or` FuTURl !h•`3 ()L sTOie.r G T■K ROOF ACCES S TAIR _f_ o €e TAkf 2 "P -I2 p_ 5 AN 1 11401 Z" virfA MOP =IV l WASTE OIL •FIRED tA4, - SOT EL. 10 -O AFF l3"CP VENT UP eV? - --- A DN 7_I 1111r M IS' —_ — ____ 1445 -"Ilk_ 2 M DAY TANK ASSY WITH I Y2" VTR 1 "FtJEI. AIL SUPPL Y RETURN 'TO UH A" DN 1 4' DN P - 14 DN '4 TYR N ENGINEER'S SHOP mmiL 2" cN5 (H►J5) 1 Q" c#410NNR) --� 2"t.4.4ro(4 W6) 2" ( 4402) (BOP 20'AFF) 11441 SEE NQTE 2 - wTrRE5 UNE OF . WALK WAY r NW R. ----- U .�-- -- =3 V KOTE PIPING 142 BELOW STAIR p MATCH LINE, : SEE NOTE L ON p -Ib • --pc-2/41 SEE Nom al SEE M1.02 FCO w. — w. _full :4. _, P -15 P -►4 gi• -- SIGN SHOP F rot hIORK I ►J'r'N I� AREA 5C�' _ I FLOOR PLAN - SECTOR A - PJP1N i SYS TEM STORES 1415.01 DESIGNED: R NICHOLS RENOm: D CRIPPEN 114a, IY4" NWS (5,46 �r x � Y4" ICILJIZ t,1 t000) Iy4 ,, 1...1 �DL T zouo) - I V4'' N �R Sor r1 tows) B. HAMBUN v CHECKED: J TURNER NW5 APPROVED: _. P -14 P -15 CONTIV4CT NO: 2 *C)N Z G ND UM C331 43C PROJECT AMAGER: G STRONKS $I B ISLER MIS NO: 432620 elow raiQIEST: 02T-07 4 " RLDN 4" ORL DN 4 "GA5 FOR RL - OPNL. CONNI, 5E6 : DETAIL 4 1 /8 " =1 -0" ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: #51 ..••••••••• - -. 2M V DN (TYP) l -I , e}OTEL g 1 - O AFF(TYP) cw PRV STATION, SEE F -MIG 3" 994-0 3.v" ON f NOTES: P -15 OVEzet,oi i caikr J 1. REMOVE WASTE OIL UNIT HEATER, 8" DIA EXH FLUE THRU ROOF, WASTE OIL TANK, PUMP AND ASSOCIATED PIPING. SEE DETAIL A/115.02. 2. REMOVE 2" CHS (HWS) & 2" CHR (HWR) PIPING FROM FIRST FLOOR MECHANICAL ROOM TO EXISTING HP /CHLR -1. SEE DRAWING 116.01 . 3. REBALANCE HEATING COILS & UNIT HEATERS. SEE DETAIL F/115.02 AND DRAWING I16.04. 8" FIRE WET t DRY PIPE SPRINKLER SERVICE ON VALVE ASSY G" STANDPIPE DRAIN 3 "AFF. Isi101-10i0? Icing County Department of Transportation I J L-IAU... METRO TRANSIT DIVISION SOUTH BASE -- WEST SOUTH FACILITIES HVAC UPGRADE PROJECT FIRST FLOOR SECTOR A PIPING goon' RAW Roof• C.211, Wei • CRY OF T E1 u VED OCT 2 7 24 • PERMIT E'ER v) w 1.7 Z W O D > ff a a L.Li W Q LI` D V)V) w °o w Imo IX 0 0 > p J D Z c z Z w Woo CD w > w ZZ Q Q _ I— u) Z Z Q D Z Q Z =mo z F_ O ._I w °D o o (n o Z Wow 16 U� W W I o DATE: JAN 2004 DRAWING No: M1.01 SHEET NO: OF 6 27 ommal W X SEE NOTE 3 UH• 1 SEE NOTE 3 • DN UH -I • SEE .p -t9 A CAN, SEE err ALL ,' F -MI • AIR DV" �Dt BY APP'D DATE SEE NOTE 1 (BOP 9' AFF) Zs TP1/4hitt vempis up fl1rou&H ROOF !i LW—.(M's ` Jr I2'7 DRIVE, TNRU 4 O L 4.1%. ail.. CAN -Irru 1-41 5ee GGTAIL Y 101 GW -1, HOLD 1 t , rr TO J0I6r', 1" v TO P -1 C1.45.4F C33143C ONE INCH AT FULL SIZE 4" 61 .. IU'1Z E T TER 8Y WASH. NAT 6■, 0.500 GF'H) King County Department of Transportation NOTES: 1. REMOVE 2" CHS (HWS) & 2" CHR (HWR) PIPING FROM FIRST FLOOR MECHANICAL ROOM TO EXISTING ; HP /CHLR -1. SEE DRAWING 116.01. 2. REMOVE 2" CHS (HWS) & 2" CHR (HWR) PIPING FROM POC TO EXISTING HP /CHLR -2. SEE DRAWING 116.01. CONNECT 2" CHWS & 2" CHWR PIPING TO EXISTING AT POC AND ROUTE TO CHILLER CHLR --1. SEE DRAWING 116.02. 3. REBALANCE HEATING COILS & UNIT HEATERS. SEE DETAIL F/115.01 AND DRAWING 116.04. . METRO TRANSIT DIVISION SOUTH BASE —WEST SOUTH FACILITIES HVAC UPGRADE PROJECT FLOOR PLAN SECTOR B PIPING DATE: JAN 2004 cn ° w 0D> tr X00 w J � U c�n w 0 m 0 w I mo Q_ J coo > J cn oo o (j) VI w W Z X w 0 0 CD w w W w Z < Q X I- cn O Z Z Z z cn Q z = ; w � 1- Z ct O. Z co ci c ,QO O z wo w w � w W W H 0 DRAWING NO M1.02 ENO: OF 7 27 g • .w I . .r..M '' .. ,.. •A . -.- .. rte`' ��A t^ !.�S Y•M.w. ..�rly�y ...g.. ,f �. `•yy,�� : 0 w CL *It U o a V oQ N N 0 4 No. x x REVISION • 0 0 •i X X AHU -2 BY APP'D DATE 0 SEE NOTE 1 SEE r1OTE 3 x 0 0 HP /CHLR -1 SCALE: 1/8"=1'-0" 1 I ROOF PLAN SECTOR A PARTIAL PLAN SEE WILZ x • Ir A rod PH Wen" raW HP /CHLR -2 1 0 i 0 0 O • 1 AHU -3 I L_J, X R NICHOLS 1l /� owwN: r B wvaeuN J TURNER RE : O CRIPPEN x C33143C .M PROTECT MANAGER: G STRONKS APPROVED: B ISLER e) I MIS N0: 432620 sac Karst: _02T -07 CONTRACT NO: 1 /8 " =1 -0" ONE INCH AT FULL SIZE ir NOT ONE INCH, SCALE ACCORDINGLY STE LOCATION No: X51 a King County Department of Transportation _. .... .F.... 1 NOTES: . REMOVE HEAT PUMPS HP /CHLR -1 & 2 INCLUDING CURBS. SEE SPECIFICATIONS FOR REQUIRED METHOD TO REMOVE EQUIPMENT FROM ROOF. RECOVER REFRIGERANT PRIOR TO REMOVAL OF EQUIPMENT FROM ROOF ACCORDING TO THE REQUIREMENTS OF THE ENVIRONMENTAL PROTECTION AGENCY AND THE FEDERAL CLEAN AIR ACT. REMOVE EXISTING WALK PADS SHOWN CROSS HATCHED. PROTECT EXISTING ROOF WITH PLYWOOD SHEATHING PER SPECIFICATIONS. REMOVE ROOF MEMBRANE AND INSULATION DOWN TO ROOF DECK WITHIN AN AREA 24" OUTSIDE OF EXISTING CURB. RESTORE ROOF AND EXISTING ROOF PENETRATIONS. SEE DRAWING AS.Oj. .3. REMOVE EXISTING 8 "0 UNIT HEATER EXHAUST AND 32 X 32 CURB. REMOVE ROOF MEMBRANE AND INSULATION DOWN TO ROOF DECK WITHIN AN AREA 12" OUTSIDE OF EXISTING CURB. PROVIDE 2 "X 2 "X 1 /4" STEEL ANGLE IN EXISTING ROOF OPENING TO SUPPORT THE NEW ROOF DECK SECTION. PROVIDE RIGID INSULATION AND PATCH ROOF MEMBRANE PER DETAIL gA5.01. i t 2. REMOVE EXISTING RELIEF HOOD. EXISTING CURB TO REMAIN IN PLACE. PROVIDE NEW 30 X 30 EXHAUST DUCTWORK. SEE DRAWING 111.04. 141 0 It- I ,9% METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES MAINTENANCE HVAC UPGRADE ROOF PLAN SECTOR A DEMOLITION • : :..:. •':w . , RECEIVED CITY OF TUKWILA OCT 2 7 2014 PERMIT CENTER riitm M ATE: JAN 2004 ~NC 111.03 SHEET NO: OF 8 27 0 i css >0 o g r C O 0 n- No. X (REVISION +i 0 • x BY APP'D DATE x x SEE NQIL2 SCALE: 1/8"=1' --0" x x 1 ROOF PLAN SECTOR A PARTIAL PLAN V x EXPIRES 11/9 • X R NICHOLS DRAWN: B HAMBLIN CHECKED: J TURNER RECOMMENDED: D CRIPPEN x PROJECT MANAGER: G STRONKS APPROVED: C33143C B ISL.ER IBIS NO: 432620 INK 1169ASr: 02T-07 t CONTRACT NO: X . i x SCALE. r " 1 /8 1 -o ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: #51 King County Department of 1 Transportation NOTES: 1. INSTALL CHILLER CHLR-1 AND CURB. SEE DRAWING 111 , 2. INSTALL NEW WALK PADS (NP OF 18) AND CRICKET WHERE SHOWN. SEE DRAWING AS.OZ. 3. PROVIDE NEW 30 X 30 EXHAUST DUCTWORK ON EXISTING CURB. SEE DRAWINGS x5.01 & 115.01. 4. PROVIDE NEW OA INTAKE HOOD & CURB. SEE DRAWINGS A5.01. __ ALM5.01 INSTALL NEW WALK PADS (TYP OF 8) WHERE SHOWN. • 6. PROVIDE NEW DRIVE CHANGES ON AHU -2 SUPPLY FAN. SEE DRAWING 118.04. REBALANCE ENTIRE AHU -2 DUCTWORK SYSTEM. SEE DRAWINGS 04.04 do U4_05. M METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES MAINTENANCE HVAC UPGRADE PROOF PLAN SECTOR .A RECEIVED CITY OF TUKWILA OCT 2 7 2N4 PERPArt CENTER I DATE: JAN 2004 DRNMNG : 1.4 1.04 SHEET NO: OF 9 27 t1 o Iii ga No. REVISION SEE NOTE 1 FLEXIBLE CONNECTIONS 2" BALL VALVES • 7'-8" NOT TO SCALE SECTION ri ; SCALE: 1 /2" n. A BY APP'D DATE SCALE: 1 /2"= 1 —0" A5.04 ROOF PLAN SECTOR B PARTIAL PLAN VAVAW AVAWAVAVAVAVAWAV A 7 0000000000Av.verAve VV 00000000.•000000 VAVAVAW V V • A V VV VVV WV .0A VVVVV vAtv0 7 000006•0006•0000. AWAWAWAWAWAVAVAWAWAWAVAVAWAVA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA OVAWAV orAvAVAWAwAV W v v v v v v v v v v v v A w .w INNS (WM 6WW. 111.0 ■••••• CHLR— 4 1 6' —1 0" 1 0T TO SCALE 1€ FLOW SWITCH SECTION SCALE: 1 /2" = 5 I COWS 1 1 /9/ 5 NNW. •••■••• r • • • R NICHOLS DRAWN: B. HAMBUN CHECKED: J TURNER RECOMMENDED: PROJECT MANAGER: G. STRONKS A I APPROVED: B. ISLER 15 es NO: 432620 1101IK IIEOLIESt: 02T-07 CONTRACT NO: CHLR— /4"=1 ONE INCH AT FULL SIZE 1• If NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: #51 ..t CRICKET MINIMUM SLOPE 1 /2"PER 1 r King County Department of Transportation 1 ,o■ NOTES: CHILLER AND CURB. . INSTALL THE NEW CHILLER ON THE NEW EQUIPMENT PAD. SEE DRAWING NO. A5.02 FOR DETAILS ON THE INSTALLATION OF THE NEW CURBING. 2. SECURE CHILLER ON EQUIPMENT PAD PER MANUFACTURERS RECOMMENDATIONS. ROOF PLAN SECTOR B le 3. PROVIDE VIBRATION ISOLATION BETWEEN 4 METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT RECEIVED WY OF TUKWILA OCT 2 7 20114 PERMIT CENTER DATE: JAN 2004 DRAWING HOE M 1 .05 SHEET NO: OF 10 27 No. REVISION -1/4 I• /4 1 -1/4 -1/4 o 1 - VESTING CA °PEf'JTEh S SWOP BY APP'D DATE 1 • 2 -1/2 / 1 -1/E 2 -1 4 I 1 -1 2 0 • 0 2 1 2 • c 0 ALTERED 2 0 FORST AND 105 I PARTIAL PLAN SCALE: 1/8"=1' -0" awed ASSEMBLY FIRE PROTECTION /2 0 1 -1/4 • 0 I - 112 0 1 -1 4 1 - ALTERED WALL PANEL STORAGE & SUNASSEMB 0 1L 1/2 0 EXDSTING ElitEnnOCAL -1/2 4 4 0 ALTII S4dGl & SUBASSEMBLY UN 1 �nrni i IYILI�I I • D • 4 ExPMtES 11/9/ EMISTORCP 1 AL • R NICHOLS DRAWN: B HAMBLIN CHECKED: J TURNER wh e RECOMMENDED: ._ D CRIPPEN 1 • 1-1/4 • SEE MOTE 2 SEE NOTE 2 t -t /a -ilk • 1-1/4 • 1-1/2 SEE NOTE 2 /4 1-1/2 • PROJECT G STRONKS APPROVED: B ISLER IBIS NO: 432620 wows : 02T-07 CONTRACT ND: C33143C SI i 2 r -1/2 • -1/2 • UTE 'RED -1/2 • -1/2 • i/8"=1 ' -0' ONE INCH AT FULL SIZE t' IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: X51 1-1/4 • -1/4 • • • 1 -114 • King County Department of Transportation i NOTES: ALL WORK SHALL BE IN ACCORDANCE WITH NFPA 13 AND REQUIREMENTS OF THE TUKWILA FIRE DEPARTMENT. 2. PRIOR TO THE REMOVAL OF EXISTING OUTSIDE AIR DUCTWORK, REMOVE EXISTING SPRINKLER HEADS AND BRANCH PIPING BACK TO MAINS AND CAP. SEE DRAWING 144.04. , r 3. SPRINKLER RISER IS LOCATED AT COL.B D/1 -2. • 1 • tr Mo LI, 9 l 8 METRO TRANSIT DIVISION SOUTH BASE - WEST FACILITIES MAINTENANCE BUILDING FIRE PROTECTION CITY of CIT TUKWILA OCT 2 7 2014 PERMIT CENTER DATE: JAN 2004 DRAWING Nor M4.01 MEET NO: OF 111 27 8Y APP'D DATE S S S S INV • 107 2 3/4" 1 1 1/4" A C 1 PARTIAL PLAN SCALE: 1/2"=1' -0" 3 3 ._ i = 0 0 1 1/4" UP 2" UP ar"v) ' un z i i a w I v v ri. 3" UP MU 3 " /// • CHS lams its/ — 1 R NICHOLS at/IRN: ETK -1 K-2 I I I J G STRONKS APPROVED: I CHWP-1 I CHWP- 1 Al HWP -1I I HWP-lAj I HWP LHWP PROJECT MAIDS GER: e isLER � 1 leiS 432620 sows: 02 CONTRACT NO: • (E) (E) (E) (E) (E) (E) SCALE: 1/2 " = 1 '--0" ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION No: X51 King County Department of 1r anaporlatian - • - ...+ .....- .v....a.I. r.- ..:..= .:. -.M. ...4r..rL NO 1. NUMERICAL SYMBOLS SHOWN ON THIS DRAWING CORRESPOND TO SYMBOLS SHOWN ON DRAWINGS 114.03. 116 -01 2. REMOVE 2" CHR (HWR) PIPING FROM POINTS 3 TO 4. POINT 4 IS LOCATED ON MEZZAINE MECHANICAL ROOM 10' r AFF. TURN OVER EXISTING PUMP PP -2 TO THE COUNTY. SEE DRAWING 1.01 ALIUGM 3. REMOVE 2 CHS (HWS) & CHR (HWR) PIPING FROM HEADER 5 -6 TO ` HP /CHLR -1. TURN OVER EXISTING PUMP PP -1 TO THE COUNTY. SEE DRAWINGS Id1.01. 111.02 & 114.0§. 4. REMOVE 2" CHS (HWS) & CHR (HWR) PIPING FROM HEADER 5 -6 TO POINTS 9 &10. 5. REMOVE 2" CHR HEADER FROM POINT 5 TO 6. REMOVE 6" +/- SECTION OF RISER AT POINT 6 TO ALLOW INSTALLATION OF AS--1. SEE 6. REMOVE 3" HWR HEADER FROM POINTS 7 TO 8. REMOVE 12" +/- SECTION OF RISER AT POINT 8 TO ALLOW INSTALLATION OF AS -2. SEE MMHG Pala. REMOVE 2" CROSS OVER PIPING INCLUDING CONTROL VALVES FROM 3" HWR HEADER TO CHS (HWS) & CHR (HWR) MAINS (4 NP). REMOVE 3" HWS & HWR PIPING FROM HEADER 7 -8 TO BOILER. 7. REMOVE 3/4" CHEMICAL POT PIPING FROM POINTS 11 & 12 TO 2 CHS • (HWS) & CHR (HWR) MAINS. 8. REMOVE 1" MU PIPING FROM POINTS 13 & 14 TO 2" CHS (HWS) & CHR (HWR) MAINS. 9. REMOVE 1" MU PIPING FROM ETK-1 TO BOILER. CAP 1" MU PIPING WHERE SHOWN. M METRO TRANSIT DIVISION SOUTH BASE •- WEST SOUTH FACILITIES HVAC UPGRADE PROJECT MECHANICAL ROOM DEMOLITION If L RECEIVED CITY OF TUKVVILA OCT 2 7 2004 PERMIT CENTER DATE JAN 2004 DRAWING No: 1.44.02 SHEET NO: OF 12 27 MIMEO 3 .8 w c4 § ‘,14 5 4 2" JET 11 3/4" 1 1 1/4" A 107 OC HWC HW CW 2" UP PARTIAL PLAN SCALE: 1 /2 "= 1' -0" 11 N 2" UP 2" 0 D 1 1/4" UP 2" • Nt- 4) V tY Tr" v) cn N" \n v\ \n ait -- 3" UP MU er z MU 3" MU 2" „"/ 4 1 i „ Of • CHS CHR • HWS 4 ” 1 --1/4" PP -1 ) HWS AS AS - HWR CV - 2" I AAV AAV [FP=771 (BELOW) (ors ,1h/3 1 C COMM : V R NICHOLS B HAMBl1N CHECKED: J TURNER RECOMMENDED: D CRIPPEN ETK- -2 ETK -2 PROJECT MANAGER: G STRONKS APPROVED: 8 ISLER NNS NO: 432620 wows maw O2? 07 CONTRACT No 1 HWP -1 I IHWP -1 A I 1 HWP-21 HWP-31 SI C33143C (E) (E) (E) (E) 1/2"=1'—O ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: X51 King County D.p.rcmnt or Transportation NOTES: 1. NUMERICAL SYMBOLS SHOWN ON THIS DRAWING CORRESPOND TO SYMBOLS SHOWN ON DRAWINGS 144.02. 116.01 2. CONNECT 2" CHR PIPING TO POINT 3 1& ROUTE TO POINT 4. POINT 4 IS LOCATED ON MEZZANINE MECHANICAL ROOM 10' AFF. SEE DRAWING 115.01 3. CONNECT 2" CHR PIPING TO POINT 5 & ROUTE TO POINT 10. 4. CONNECT 2" ,CHR PIPING TO POINT 9 4& ROUTE TO POINT 6. PROVIDE AIR SEPARATOR AS -1 WHERE SHOWN. 5. CONNECT 3" HWR PIPING TO POINT 7 & ROUTE TO POINT 8. PROVIDE AIR SEPARATOR AS -2 WHERE SHOWN. 6. CONNECT 2" HWS & HWR PIPING TO HEADER 7 -8 & ROUTE TO BOILER. PROVIDE CONTROL VALVE CV -1 AND PUMPS PP -1 & PP-1A WHERE SHOWN. SEE DETAIL 015.02. . p 7. CONNECT 1" MU PIPING TO POINT 13 & ROUTE TO AIR SEPARATOR AS -2. ROUTE DRAIN FROM MV TO EXISTING FLOOR DRAIN. 8. CONNECT 1" MU PIPING TO POINT 14 & ROUTE TO AIR SEPARATOR AS -1. ROUTE DRAIN FROM MV TO EXISTING FLOOR DRAIN. 9. CONNECT 3/4" CS TO POINT 11 & ROUTE TO POINT 15. 10. CONNECT 3/4" HWS TO POINT 12 & ROUTE TO POINT 16. Mo METRO TRANSIT DIVISION SOUTH BASE — WEST SOUTH FACILITIES HVAC UPGRADE PROJECT MECHANICAL ROOM INSTALLATION OF� u OCT 2 7 2004 Pew CENTER DATE: JAN 2004 DRAINING NO: M4.03 SHEET NO: OF 13 27 P .r • p tEX2o tiVis 1080 r .._._ . SEE NOTE lo S " d 4 " � 4 "0 1-Df r 570 _.__ BoD LOS" 'ld �Cli O*Io- t,'I I� I cocieIr. vr� t c I - L.1. � rto ^ 915e. HA. ,`' 1 A 5HOW 1 1(IIN ^T0 e'•o App (.QNNeC"f 8 o g WIN romv oviD 'D origA rrION 'r 0 I (,QNNec? TO SEE NOTE 1 1030 z•xf+ 24,00 \-32 SEE NOTE 1 c, LT'-O" 3Dx I+ SEE NOTE 2 aoT 01` 50 to'-o" okfif IIJ'TA$E Lawn LMA BQD 18' AFF 20XIo FLLL $&cTo A HVAc M 1 DW WA. IOC I` ON GMO Dh l Gx1O DhI IMI4 0,4 N DucTS NJ 4016T SPAct 1.0X36 u, IOx3Gru'' 40X2,0 O .F FOR FUTURE S2.X IL rx: 1 4" -0 ' MORT►CeR 2. CLEAN THE INTERIOR OF AIR HANDLERS AHU -2 • & 3. NOTES: 1. CLEAN THE INTERIOR OF AHU -2 & AHU -3 SUPPLY & RETURN DUCTWORK SYSTEMS FROM UNITS TO AND INCLUDING GRILLES /REGISTERS AND DIFFUSERS. 3. REMOVE OUTSIDE AIR INTAKE DUCTING FROM AHU-1 TO THE OUTSIDE AIR INTAKE LOUVER LOCATED ON THE NORTH ELEVATION. 4. PROVIDE 18 GA GALV STL SHEET METAL COVER OVER THE EXISTING LOUVER OPENING ON THE INTERIOR SURFACE. EXISTING LOUVER TO REMAIN IN PLACE. PROVIDE 1-1/2" THICK INSULATION ON THE INSIDE SURFACE OF THE SHEET METAL COVER. INSTALL INSULATION WITH VAPOR BARRIER TO THE INSIDE OF THE BUILDING. 5. REMOVE STEEL ANGLES AT EACH SIDE OF OPENING AND INFILL CMU WALL. SEE DETAIL )G/115.02. PAINT TO MATCH EXISTING SURFACES. 6. EXISTING 28X16 OA DUCTWORK TO REMAIN IN PLACE. SEE DRAWING 145.01 FOR CONTINUATION. 7. REBALANCE AHU-1 GRILLES, REGISTERS & DIFFUSERS PER CFM SHOWN (22 TYP). R NICHOLS DRAWN: B HAMBLIN `1441321 D CRIPPEN PROJECT MANAGER: G STRONKS ' No. REVISION BY APP'D DATE CHECKED: J TURNER V�1 APPROVED: B ISLER 12) I as N0: 432620 ow REQUEST: 02T -07 CONTRACT No: C33143C SCALE: NONE ONE INCH AT FULL SIZE .1' r NOT ONE INCH, SCALE ACCORDINGLY SITE UocnnON NO: X51 METRO TRANSIT DIVISION SOUTH BASE — WEST SOUTH FACILITIES HVAC UPGRADE PROJECT FIRST FLOOR SECTOR A HVAC � o (n w ./.4J w O ff 0 0 J Li w Q� C.)u w 0 w cr CL CD 0 IX oo Z J 0 O oc Z Z W W W w co ww < = Q I--- ZZD • Z cn Q Z Y .1 w 0 Z 1- Z OJ T Z m C] O Q (n Z w 0 0 0 LLI w W w H1-O DATE: JAN 2004 DRAWING No: M 4.04 SHEET NQ: OF , 14 27 N • ... 4t.r • '1.. ..rr; 0w+ ir IIM eavvaaresoci1 9y. -..mom � Io:AM«h.• aastoawt+... • I .. . 'y • No. 2204 10 DN 0 20x14 - -----60 o� C PREP SHOP r ll D• `.J 510 ) .. 1P IC. 8 drop 1(•A 14 TYt ( j) 14x246 10 1040.. t'' MATGHLL.INE 9Co x 3(o Ko x 6 ESA IS MAKE UP �D 3Z K ZD � 1 � ► DUCT 15Y OTHERS I(/x12 � P L) 111 Q•D4J 71 " 111- 11111111111115 aftileill1111111.11 1111110 MOP 28A - • � 6 i/i?MII ^ Z4x4 V j 82 20_ • vb. 4ar REVISION • SEE NOT 1 BY APP'D DATE L. 18 ?+4x DM 0 , ow SEE NOTE 2 ---\ l 404) 1:7C VENT THItLi '1� � RG�'JF cops, 'Tb Z'ste friqP". PRONilDe 44 /'T 2' Akr-C FVFL DRYClR- K.Ex GoNN• 3 ,s 10' PU(1• 1' 1sNATCi carte 1[erUle 4 OC•NQ 18"AEioVr. RCVIr FLOOR PLAN E TO SCALE I /S" s 0 _ 0" S0 +i20 41[011€0g1 8x1 s ( • xrZ v 1P ( }8 tic 10 . FD,T °1` ALL DI._ ^T ININ.A. DESIGNED: R NICHOLS ORANRI: 8 HAAABUN 'eoi- CHECKED: J TURNER rtEiom: D CRIPPEN CONF 115 PROJECT MANAGER: G STRONKS )/./ APPROVED: B ISLER IBIS NO: 432620 WO* REQUEST: 02T -07 CONTRACT N0: C33143C NONE ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: X51 King County Department of Transportation NOTES: CLEAN THE INTERIOR OF AHU-2 SUPPLY AND RETURN DUCTWORK SYSTEMS FROM UNITS TO AND INCLUDING GRILLES, REGISTERS AND DIFFUSERS. 1 2. REBALANCE AHU-1 GRILLES, REGISTERS AND DIFFUSERS PER CFM SHOWN (15 JYP). fri o it- 1 METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT FLOOR PLAN SECTOR B HVAC . .. +r. i.r..X r.�d..�.. RECEIVED CITY OF TUKWILA OCT 2 7 2004 PER•r' CENTER (n W w LI- o0 W J �c 0 w � CC mn w �� cr O O Z d J (n F-� 0 cn V) Z Z w o o m w w p < Ei Z Z D cc 0 3 � Z (n Q =mo I- 0 Z Z �. cr �OJ z� 3 O , w (n o o Z 4 W j, W O V) W W w 0 DATE: JAN 2004 DRAW HO: M4.05 SHEET NO: OF' 15 27 YAM. n! ..y +IM r � AMEND W X .1 . ... �c ;.... NOTES: 3. REMOVE 18X54 DUCTWORK FIRE DAMPER AND STEEL ANGLES AT EACH SIDE OF WALL OPENING. 4. REMOVE PP--1 AND PP-2. TURN OVER TO COUNTY. SEE DRAWINGS M4.02 & M6.01. Sal' eL 8 PLFIG• LI IJBD SEE NOTE 2 a HbMd 6T/c•Ic SEE NOTE 3 eLEG"fRIG44L SeE PeTAIL 0454 ..�.� 18x62HOP 24%44 MoD MU SEE NOTE 2 ALTERWATOQ oL PAL 2" IP-13 SEE NOTE 1 AR PAN/ V1'OTI01M 11 I I I rtis II I THW E'TK- I r a Ue 44' UP 141.1 Of R NICHOLS D CRIPPEN B MAMBLIN� CHECKED: - J TURNER B ISLER 1SNO: 432620 wow REQUEST: Ito )C IS D J. we x � v� ttx�x� r � z i x2 s�ve R � sf. P a.�� ��) x SO --L 18 K I4 PROJECT : G STRONKS — �wrno�D 004 .0 ISM& !1F -2. 2.4x 12--- -� 17 PIJ 14'{� p�iI.ER dineCiir 16 )4.14 '. IVO ttA 14 MATc.14 L11J e 5e E aW F- 414 AND F ~Mb ONE INCH AT FULL SIZE King County Department of Transportation METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT MECHANICAL ROOM PLANS ac SECTIONS SfAle 54x24 Map, POO GISCII UP 32x,16 . 18X22 frj:I SEE PREFILTER 1`1444. PI LTV NC f IL Vre. 18 icy 13DO (14 w2G DUCT .._ CA16T) . . me-ip' C� " ( 3 tt x OAS* ® Sact► (� 41034 ® 4 K34 111494 ® VS% 3 pee* ® 5/11 DWINC NO: M4.06 cn ° w (n il z w 0 > E00 Q J W V 0 Cr_ w n co O cr oon w � o o Z= < (/) h. = Z 0 o 0 z Z Z W � � b o o W W w Z < 2 Q Z Ct Qw CC 0 w z � m a w � I 0 Z Cr o = , o I ( 0 Z W 0 W '` W W W IT- - DATE: JAN 2004 _.............. a...... ................r..•••.•...11,01 ■... .....•■•.....+ ,. - «+:. ».. .....44 . u.14: , ••••• •'... ..s"•Y.w No. f HWR VIP U//Z NINE 107 8" CMU E C' 1 11C w PATCH /PAINT 6" DIA WALL PENETRATION IN 12" THICK CMU WALL (2 TYP) SEE NOTE 3 HWS 2" CHS AND CHR TO CHILLER EXISTING 30X30 UP TO ROOF REVISION BY APP'D DATE BOD 20'AFF PARTIAL PLAN NOTES: 1 . PROVIDE 30X30 EXHAUST DUCTWORK. SEAL SEAMS WEATHER TIGHT. INSTALL ON EXISTING CURF3. PROVIDE BACKDRAFT DAMPER IN EXISTING CURB OPENING. SEE DETAIL A/A5.01 2. PROVIDE DUCTWORK SUPPORTS. SEE DETAIL GA15.02 de DETAIL D /A5.01. 3. PATCH FLOOR & WALL PENETRATIONS (4 NP) SEE DETAIL B /M5.02. 4. PROVIDE 54X18 OUTSIDE AIR DUCTWORK FROM EXISTING 54X18 DUCTWORK FROM POC TO OUTSIDE AIR INTAKE HOOD. PROVIDE TRANSITION FROM 54X18 TO OUTSIDE AIR HOOD. SOUND LINE DUCTWORK PER SPECIFICATIONS. 5. PROVIDE OUTSIDE AIR HOOD WITH CURB. SEE DRAWING A5.01. 6. RELOCATE EXISTING 1" ELECTRICAL CONDUIT AS REQUIRED TO INSTALL NEW 54X18 OUTSIDE AIR DUCTWORK. 7. INFILL EXISTING OPENING IN 8" CMU WALL. SEE pEfAlj C/Y5.02. FOR TYPICAL REQUIREMENTS. 8 • CONNECT TO EXISTING 28X16 DUCTWORK & ROUTE THROUGH EXISTING WALL OPENING & CONNECT TO NEW 54X18 OUTSIDE AIR DUCT. PROVIDE 1 -1/2 HOUR FIRE DAMPER WHERE SHOWN. SEE DETAIL D /115.02. 1 SCALE: 3/8"=1' -0" cr U U) U 28X16 FD PATCH 6" DIA FLOOR PENETRATION IN 8" THICK CONCRETE FLOOR (2 TYP) SEE NOTE 3 POC SEE NOTE $ or ACCESS PANEL 54 X 18 UP SEE NOMA AHU- 2" HWS AND HWR TO FIRST FLOOR OFFICE I CMS Vispl BIRD SCREEN HOT DIPPED GALVANIZED UNISTRUT (TYP) EXISTING R NICHOLS DRAWN: R NICHOLS J TURNER RECOMMENDED: 0 CRIPPEN PROJECT MANAGER: G STRONKS ti B IsLER $ t EXISTING CURB FLOOR NEW 24" SQUARE (2 NP) CIS N0: 432620 IF NOT ONE INCH, NOM Eu: 02T-07 SCALE ACCORDINGLY CONTRACT N0: - sfTE WCATiON No: C33143C 30X30 EXISTING ELECTRICAL CONDUIT SEE NOTE 6 X51 AS NOTED ONE INCH AT FULL SIZE SECTION 12' -0" SCALE: 3/8 " =1' -0" SUPPORT (2 TYP) SEE NOTE 2 30X30 EXHAUST SEE MOTE 1 ^C 0 V King County Department of Transportation FE' ( ' 1 M1.04 M5.01 N • •, SECTION SCALE: 3/4 " =1' -0" M1.04 OUTSIDE INTAKE HOOD SEE NOTE 5 54X18 • 24 REVIEWED FOR CODE COMPLIANCE NOV 1 0 Z004 SOUND LINING FD (1 -1/2 HR) 30X30 (EXISTING) NEW CURB NEW ROOFING • CIty 'uKWM N fr11) METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT PARTIAL PLANS & SECTIONS ROOF SEE NOTE 7 SEE t POC RECEIVED CITY OF TUKWILA OCT 2 720.4 PERMrT CENTER DATE: DRAWING No: EXISTING 54X24 OUTSIDE AIR INLET TO AHU -1 SEE NOTE 1 TURNING VANES BACKDRAFT DAMPER EXISTING CURB ROOF JAN 2004 M5.01 SET No- OF 17 27 a x =W a2 STRUCTURAL SUPPORT � 1 / 2" - / - )Y , / / 1/4" • WASTE OIL / PUMP CAP DAY TANK FLOOR 1" PIPE SCALE: NONE 3/4" DRAIN VALVE (NP) DETAIL SCALE: HALF REVISION a IPP—iI IPP-1AI 3/4" WASTE OIL UNIT HEATER M T I WASTE OIL HEATER & REMOVAL DETAIL M4.03 M6.02 • REMOVE 8" EXHAUST FLUE UP THRU ROOF. PATCH ROOF PER DRAWING 111.03, CAP (2 T(P) BY PATCH & PAINT 2" VENT THRU EXTERIOR WALL BOP 8' AFF SEE DETAIL B/M5.01 2" 2 i APP'D DATE PREPARE SURFACE WITH EPDXY BONDING COMPOUND. MASTER BUILDERS LPL1001 BALANCING VALVE (METERING) HWR • .. .: CONTROL VALVE DETAIL SCALE: NONE A PIPE PENETRATION SEE DRAWINGS FOR SIZE —\ DETAIL SCALE: NONE • NOTE: REBALANCE HEATING COILS AND UNIT HEATERS. SEE DRAWING 16.04 FOR REQUIRED FLOW RATES. M5.01 EXISTING FLOOR OR WALL. SEE DRAWINGS FOR THICKNESS ▪ V • 1 N FI LL WITH PATCHING CONCRETE HEATING COIL (EXISTING) • GROUT ALL CELLS AT PERIMETER OF OPENING ROOF DECK MOWS „ pi s • EXISTING 54 X 22 DUCT OPENING I N FI LL WITH CMU BLOCKS 3" DIA (MIN) SCH 40 STL PIPE. SEE DRAWINGS FOR HEIGHT HOT DIPPED GALV AFTER WELDING DESIGNED: R NICHOLS DRAWN: R NICHOLS CHECKED: J TURNER RECOMMENDED: D CRIPPEN DETAIL SCALE: NONE DETAIL SCALE: NONE PROJECT MANAGER: G STRONKS APPROVED: B ISLER IIIIS NQ: 432620 nowt MUM: CONTRACT NO: .61 C33143C 02T-07 X51 ro M5.01 AS SHOWN M1.03 ONE INCH AT FULL SIZE 1' IF NOT ONE INCH, SCALE ACCORDINGLY SfE LOCATION NO: , • • J .i � -_ . , r •. • •d S .: 1!Mu"+! I ••'711... • V••• •••••r. ••. -i.r.w EXISTING 8" CMU WALL #4 REBAR MAX 24" O.C. EACH WAY 1 /4" THICK STL PLATE SEE DRAWINGS FOR SIZE 1 /4~ V #4 REBAR 18" LONG GROUTED INTO EXISTING CMU MIN 8" 18" X 18" X 1/4" STEEL PLATE SECURE TO ROOF DECK WITH #10 SCREWS 0 6" O.C. King County Department of Transportation STEEL STRAP DETAIL SCALE: NONE Me V MECHANICAL DETAILS CONCRETE BLOCK WALL NOTE: FILL WALL VOIDS AROUND OPENING WITH GROUT D I M5.01 METRO TRANSIT DIVISION SOUTH BASE- WEST SOUTH FACILITIES HVAC UPGRADE PROJECT CLEARANCE ALL AROUND WELD (TYP) SLEEVE RETAINING ANGLES RECENED ar OCT 2 7 2014 PERMIT COMA �.n..�.•- ..— ..w..: .- .»,n+.<, •■■■•! � - 4F +1.. .. . Y:a..Y r:.:r .- !'Q'i.'Z`... y' »'i''• 1 -1 /2 HR FIRE DAMPER 1. ATE: JAN 2004 DRAWING NO: SHEET No: OF 18 27 M5.02 0 i • 0 2 1- • o �, >° 0 0 r 08 z V N q§" No. NOTES: 1. NUMERICAL SYMBOLS SHOWN ON THIS DRAWING CORRESPOND TO SYMBOLS SHOWN ON DRAWINGS M4.Q2. X14.03 ,16.02. 2. REMOVE HP/CHLR-1 & 2 INCLUDING CURBS. RECOVER REFRIGERANT ACCORDING TO THE REQUIREMENTS OF THE ENVIRONMENTAL PROTECTION AGENCY AND THE FEDERAL CLEAN AIR ACT. REPAIR ROOF AND EXISTING ROOF PENETRATIONS. SEE DRAWING A5.02. THE RECOVERED REFRIGERANT, REMOVED EQUIPMENT, PIPING AND MISC MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OFF SITE. : TURN OVER EXISTING PUMPS PP -1 & PP -2 TO THE COUNTY. 3. REMOVE 2" CHS (HWS) AND CHR (HWR) PIPING FROM POINTS 1 & 2 TO HP /CHLR -2. 4. REMOVE 2" CHR (HWR) PIPING FROM POINTS 3 TO 4. TURN OVER EXISTING PUMP PP -2 TO THE COUNTY. SEE DRAWING Ir4.06. 5. REMOVE 2" CHS (HWS) & CHR (HWR) PIPING FROM HEADER 5 -6 TO HP /CHLR -1. TURN OVER EXISTING PUMP PP -1 TO COUNTY. SEE DRAWING Y4.00. .461A r' HP P1011114.r Fire R-v Advi Arlir D 0 11 2 " PP -1 PP -2 po i Aar of .0 I� 3 •� • m i 1 B-LI 72 GPM 1 " - • • • • • • • • • lag; 0 m � f 41 ' ° /hi 11111P2D 4.151'. Mar 7 •r it : v 41 wr4 Ally HMS / / CHR< FiVYf2? AIR SEPARATOR (TYP) • / ► • ► . ► f 1 / ? ,I 4 E.TK -1 TO DRAIN ( TYP) 80 PSI G CTYP 25 PSIG (TYP) ( CC I A HU -11 RPBFP MAX 4' -O"AFF • 11 m 4" POT FEEDER ASSEMBLY SEE F—M16 ELNP --1 A 1 1 1 1 1 1/411 IHwP --1I 1 LONER ME CH ROOM 1 • • • ► • • • • O «. 11 HWR HWS ! -31 EAST FT U ZONE • • • - T -.%F- 1 2" 1 HWP --21 SOUTH FT U ZONE - REVIEWE COMPLIANCE CODE Hp1 10 2004 BUILDING o NISION • • • O • • • • y1vs> ArrAdVI•iiial ,teHR< z z- 7 / 4. ,yam /7 BALANCING /MEASURIN VALVE CTYP> Lc A Cv =18.5 1 1 L 1 1 1 1 1 L 0-4 j 6. REMOVE 2" CHS (HWS) & CHR (HWR) PIPING FROM HEADER 5 -6 TO POINTS 9 & 10. ROOF REVISION SEE NOTE 1 HP /CHLR WITH INTEGRAL COMPRESSORS , COILS , FANS HEAT EXCHANGER AND CONTROLS ( TYP) 21/ 11 LOCKER/TOILET AREA CEI SPACE —) BY APP'D DATE r ( - —CHR 1 F f CHR I I 14' I � I /r `Fh CIL A141 M CHS CHS TYP FOR PP-2 ( FINS) ( ffiVS) ( 1MR)— ( FM14X) o t RvA' 6 10 0 1 ITIES . STORES • 7. REMOVE 2" CHR HEADER FROM POINTS 5 & 6. REMOVE 3" HWR HEADER FROM POINTS 7 & 8. REMOVE 2" CROSSOVER PIPING INCLUDING CONTROL VALVES FROM 3" HWR HEADER TO 2" CHS (HWS) & CHR (HWR) MAINS (4 TYP). REMOVE 3" HWS & HWR PIPING FROM HEADER 7 -8 TO BOILER. 9. REMOVE 3/4" PIPING FROM POINTS 11 & 12 TO 2" CHS (HWS) & CHR (HWR) MAINS. 10. REMOVE 1" PIPING FROM POINTS 13 & 14 TO 2" CHS (HWS) & CHR (HWR) MAINS. REMOVE 1" PIPING FROM POINT 14 TO BOILER. LOCATE STAINER I N HORIZONTAL POSITION ( TYP) HOSE END DRAIN VALVE M HC SELECT Cv BASED ON DESIGN GPM AT 5 PSI G PD ( TYP) 1 R NICHOLS r•. 8 HAMBUN CHECKED: J TURNER RE 0 CRIPPEN DNEZZAN I NE AE CH . , ROOM I G STRONKS APPROVED: B ISLER CONTRACT No: C33143C I PROJECT IBIS NO: 432620 VIa.0 : 02T-07 11 HWR HWS CHR CHS NONE ONE INCH AT FULL SIZE t• IF' NOT ONE INCH, SCALE ACCORDINGLY srtE LOCATION No: X51 • T TO UNIT HEATE DUCT HC' S,AH King County Department of Transportation It FLR 1 1 1 1 METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT PIPING DIAGRAM REMOVAL PECENED CRY OF TUKWILA OCT 2 7 21N4 PERAAR CENTER DATE: JAN 2004 DRAWING NO: M6.01 'PEET NO: OF 19 27 .. _ - ... ' .... • .t • ••�•di.�i!tn.t.1 .�rrr..�.ir ►• .; ,.fy . • or JCHLR-1J 1 NOTES: 1. NUMERICAL SYMBOLS SHOWN ON THIS DRAWING CORRESPOND TO SYMBOLS SHOWN ON DRAWINGS 144.02. 4M44.03 & Mt,0 . 2. CONNECT 2" CHS & CHR PIPING TO POINTS 1 & 2. ROUTE 2" CHS & CHR PIPING TO CHLR -1. 3. CONNECT 2" CHR PIPING TO POINT 3 & ROUTE TO POINT 4. 4. CONNECT 2" CHR PIPING TO POINT 5 & ROUTE TO POINT 10. 5. CONNECT 2" CHR PIPING TO POINT 6 & ROUTE TO POINT 9. PROVIDE AIR SEPARATOR AS -1 WHERE SHOWN. ROUTE DRAIN FROM AAV TO EXISTING FLOOR DRAIN. CEILING SPACE LOCKER/TOILET AREA REVISION • • 0 1 1 FLOW SWITCH N 2" BY APP'D STORES GATE CHS CHR 0 -200T L 1 N 6. CONNECT 3" HWR PIPING TO POINT 7 & ROUTE TO POINT 8. PROVIDE AIR SEPARATOR AS -2 WHERE SHOWN. ROUTE DRAIN FROM MV TO EXISTING FLOOR DRAIN. 7. CONNECT 2" HWS & HWR PIPING TO HEADER 7 -8 & ROUTE TO EXISTING BOILER. PROVIDE CONTROL VALVE CV -1 & PUMPS PP -1 & PP-1A WHERE SHOWN. SEE DETAIL E /I45.02. 8. CONNECT 1" MU PIPING TO POINT 13 & ROUTE TO AIR SEPARATOR AS -2. 9. CONNECT 1" MU PIPING TO POINT 14 & ROUTE TO AIR SEPARATOR AS-1. 10. CONNECT 3/4" CS PIPING TO POINT 11 l& ROUTE TO POINT 15. - 2" HWR _ NI 0-200T O 50 PSIG I I � 1.4o 1 . [ 8-1 1 PP -1 IPP 1 LOWER MECH ROOM CHS --= CHR - 2 HWS 3/4" (2 TYP) nwil p. o� -- - HWR 12 PSIG (2 TYP) It 0 80 PSIG (2 TYP) f \• # low V' /,rC6.i CC 2" I AHU-11 SELECT VALVE WITH Cv BASED ON DESIGN GPM WITH A PRESSURE DROP THROUGH THE VALVE OF 5 PSIG (TYP) HC i 2" 2 " grs 11. CONNECT 3/4" HWS PIPING TO POINT 12 & ROUTE TO POINT 16. 12. PROVIDE 3/4" FEMALE HOSE CONNECTION WITH BALL VALVE. ---� -- CHR MU a.. 1- -HWR— r - — -- ----- CS ► CHS R NICHOLS DRAWN: 8 HAMBUN J TURNER D CRIPPEN � AS -2 STRAINER REMOVAL 3 " 2 2" AAV IHWP CHEMICAL FEED I PROJECT MANAGER: G STRONKS APPROVED: 8 ISLER N 432620 wow =um 02T-07 NO: C33143C (MEZZANINE MECH ROOM CV- 4 2 " ■I■lo .111111111111=11. -- HWR - HWS - CHR CHS 4 MU 3/4" TO 16 FFD NONE ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY LOCATION sLOCATION No: X51 • I HWP-3 1 EAST FTU ZONE King count Department of Transportation HWR TO UNIT HEATERS, DUCT HC'S, AHU -2 REVIEWED FOR CODE COMPLIANCE SOY 10 Z004 a� � Vomits BUILDING DIVISION 3 " 2 " 3'' - HWS >11) AAV IHWP TO FFD SOUTH ZONE FTU I t ICHWP -1AI AS-1 STRAINER REMOVAL POT (2 TYP) SEE (14 tg r METRO TRANSIT DIVISION SOUTH BASE -WEST SOUTH FACILITIES HVAC UPGRADE PROJECT PIPING DIAGRAM INSTALLATION J � RECEIVED CITY OF TUKWIU OCT 2 7 2004 PERMIT CENTER DATE: JAN 2004 DRAWING N0: SHEET NO: of 20 27 M6.02 �►:a -., . 1 1 1 1 1 1 1 L SIEMENS XX - XX M -1 FBPPIE NM -1 SIEMENS XX - XX FBPP1P AREA OF YORK - - r 1 1 1 1 1 1 L — $EE NOTE 6 PP -: FBPP1P 1 1 1 1 L _ REVISION a 1011111111111. 1111111111111111111P 11111111111111110 01111111/1M. 1111•■• 111•111111111110 1■11 11•111111•IM FCIST 10.07.0.12.031 M -4 HONEYWELL 67 - 68 FC1ALM 10.07.012.01 I M -1 HONEYWELL 69 -70 M -1 SIEMENS XX - XX FBPPIE M -1 niNFIEFAIT C1KWH 14-1 HONEYWELL 3 - 4 F KVH 14-1 HONEYWELL S - 6 CHILLER - 1 FCCNTLI feri 14-1 HONEYWELL 36 - 37 SEE [NOTE 4 SEE NOTE 7 NOTES: 1. REMOVE ALL CONTROL DEVICES BACK TO THE CONTROL PANEL NOT REQUIRED FOR NEV HOT WATER SYSTEM. 2. REMOVE ALL CONTROL DEVICES BACK TO THE CONTROL PANEL NOT REQUIRED FOR THE NEW CHILLED WATER SYSTEM. 3. PROVIDE PRIMARY /SECONDARY HOT WATER TEMPERATURE CONTROL VALVE. PROVIDE TEMPERATURE RESET OF SECONDARY /LOOP SEE RESET SCHEDULE. e FCIDIS [i1f1n7[fa TTE -7 -40/240 DFG r FBHWLT M -1 SIEMENS FC1ENA 1 0.07.0.1 1 M -1 xx - xx 34 -35 MAINTAIN A MINIMUM OF 140 DEG. F TO THE BOILER 114 THE PRIMARY A LOOP TTE -7 - 40/240 DEG F FBHWLT rixiy 14-1 SIEMENS • XX - XX FDHVPE I o.o7.aaasuJ M -2 HONEYWELL 71 - 72 4. HEATING HOT WATER PRIMARY LOOP. PROVIDE CONTROLS AS SHOWN. 5. PROVIDE BOILER RE TURN WATER TEMPERATURE SENSOR. 6. PROVIDE PRIMARY HEATING HOT WATER PUMP ENABLE AND PROOF. (2 TYP) 7. PROVIDE BOILER SUPPLY WATER TEMPERATURE SENSOR. HONEYWELL 32 - 33 14-1 HONEYWELL FLOW SWITCH SEE NOTE 3 BOILER FBOIL CTsI1f i :j 1 M -2 MANUALLY SET TO 180 DEG. F 1 1 1 L six NOTE 5 BY APP'D DATE HONEYWELL 73 - 74 AREA OF WORK (SEE NOTE 8 THRU 13) FBLDV6 M -1 SIEMENS 1 1 I 1 1 1 J TTE -3 -40/240 DEG F FCER1T [I!I:, IRLTIJ1 HONEYWELL TTE -2 - 40/240 DEG F FCWS1T . T .TETTI HONEYWELL 14-1 BHfraFd M - 1 14-1 7 -8 HONEYWELL 1 28 - 29 1 30 31 HWP -1 M -1 HONEYWELL - 30 -31 HWP -1A 9 - 10 a M-1 HONEYWELL 32 - 33 BHIF 14 -1 HONEYWELL 34 - 35 FBHP1AE UPYPF4IFILI OA TEMP ('F) 35 yv 63 14-1 HONEYWELL 14 -15 - 16 FBLDV4 1 120 SECONDARY LOOP TEMP CF) M-2 FHVP3E rorimomrini 160 HONEYWELL 38 - 39 j 8. PROVIDE CONTROLS FOR THE CHILLER TO BE INTEGRATED WITH THE EXISTING SIEMENS CONTROL SYSTEM. 9. PROVIDE CHILLER ENABLE 10. PROVIDE CHILLER PROOF 11. PROVIDE CHILLED WATER DISCHARGE TEMPERATURE FROM CHILLER. 12. PROVIDE CHILLER ALARM 13. PROVIDE CHILLER DISCHARGE TEMPERATURE MODULATION CONTROL 14. VERIFY THE OPERA OF THE DIFFERENTIAL PRESSURE CONTROL VALVE. 15. PROVIDE THE CONTRA. LOGIC AS SHOWN OWN THE SEQUENCE Off` OPERATION. HEATING HOT WATER SECONDARY LOOP SUPPLY TEMPERATURE RESET SCHEDULE TTE -8 - 40/240 DEG F FHWST M -2 HONEYWELL 3 - 4 14-1 HONEYWELL 65 -66 FHWP3P HWP -3 TTE -7 - 40/240 DEG F HWRT [IT11,11 0 Tti 4 M -2 HONEYWELL 5 - 6 TTE 10 - 40/240 DEG F FEFTUT 14-2 E. FTU ZONE 1 1 1 HONEYWELL 9 - 10 1 i oq- 18 o 11/,/ f' AIR 05 DA TEMP ('F) 67 FCPIAE M -1 HONEYWELL 77 - 78 M -1 HONEYWELL FBLDV5 fOD. 17 - 18 - 19 MODULE NO. DRAWN: 8 HAAABLII? CHECKED: J TURNER V � RECOMIADIDED: D CR1PPEN 42 SECONDARY LOOP TEMP (•F) 1 14-2 1 HONEYWELL 36 -37 HWP2E M -1 HONEYWELL 11 -12 -13 BLDV3 LEGEND TERMINAL N0. DESIGNED: R NICMOLSO'"* FCP1P i..i ilT1 =T l 14-1 1 HONEYWELL e4 - 25 F P1AP 50 (11141 HONEYWELL 26 -27 SEE4 7 MAINTAIN 20 PSIG DIFFERENTIAL M-1 CHILLED WATER SECONDARY LOOP SUPPLY TEMPERATURE RESET SCHEDULE (3 CHWP -lA FHWP2P CHWP -1 DPC1 ttj HE YWELL M-i HONEYWELL 65 - 66 CONTRACT 140: C33143C FCPIE 14-1 14-1 HONEYWELL 63 - 64 , HWP -2 PROJECT MANAGER: G STRONKS APPROVE): B ISLER 1 IOSNO: 432620 sowc INQUEST: 02T-07 HONEYWELL 75 - 76 HWS RETURN CONTROL NfG. PANEL CWR CWS COVE it 4 QV zoo BUILO , HWR FROM VALVES M -2 HONEYWELL 42 - 42 HWDP prmrAlmomq HWS TTE -09 -40/240 DEG F FSFTUT [iT I 14-2 HONEYWELL 7 - 8 S. FTU ZONE SCALE: NONE X51 1 1 1 1 RECENED CITY OF TUKWI A OCT27 ONE INCH AT FULL SIZE PERMIT CENTER IF NOT ONE INCH. SCALE ACCORDINGLY SITE LOCATION 140: r . ... .d. :. ...,.. _. . 5, . SEQUENCE OF OPERATION: /CAM& HOT WATER SYSTEM' THE HEATING HOT WATER SYSTEM PROVIDES HEATING HOT WATER FOR USE IN THE SOUTH BASE FACILITY MAINTENANCE BUILDING SPACE HEATING SYSTEM. THE SPACE HEATING SYSTEM INCLUDES THE FOLLOWING EQUIPMENT. BOILER (8 -1) PRIMARY CIRCULATIOON PUMPS (PP -1) L (PP -1A) SECONDARY CIRCULATION PUMPS (HWP -1 LHWP -1A) 3 -WAY MIXING VALVE (CV -1) AIR HANDLER UNITS (AHU-1, AHU -2) DUCT HEATING COILS IN DUCTS SERVING SHOP AND STORE AREAS. UNIT HEATERS THROUGHOUT SHOP AND STORE AREAS. CABINET HEATER IN LOBBY ROOM 101 FIN TUBE UNITS FOR PERIMETER HEATING ON THE SOUTH AND EAST EXTERIOR ELEVATIONS OF THE OFFICE AREA. i THE HEATING HOT WATER PIPING SYSTEM IS ARRANGED IN A PRIMARY /SECONDARY LOOP CONFIGURATION. THE HEATING HOT WATER SYSTEM SHALL BE CONTROLLED BY THE EXISTING CMCS (COMPUTER MONITOR AND CONTRA. SYSTEM). i ,L PRIMARY LIZIel MORNING WARM UPI AT 530 A14 (ADJUSTABLE) THE CMCS CLOCK ENABLES THE PRIMARY CIRCULATION PUMP (PP -1). UPON Pik OF PUMP OPERATION, THE BOILER IS ENABLED. BOILER OPERATION SHALL BE TIMED WITH THE START OF AHU -1 AND AHU -2. THE 3 -WAY MIXING VALVE (CV -1) IS POSITIOED TO ONLY ALLOW FLOW THROUGH THE PRIMARY LOOP. WATER IS PRE-HEATED TO THE MANUALLY SET 180 SET POINT IN THE PRIMARY LOOP. ONCE THE PRIMARY LOOP REACHES SET POINT, THE SECONDARY LEAD PUMP (HWP-1 OR HWP -1A) COMES ON (AND PROOFS) AND CV -1 MODULATES TO WARM UP THE SECONDARY LOOP. PP -1 • SHALL RUN CONTINUOUS, CIRCULATING WATER AROUND THE BOILER. NORMAL OPERATION. 1 . THE BOILER IS ENABLED WHEN THE OUTSIDE TEMPERATURE IS 63 DEG. F OR LESS. THE PRIMARY PUMP (PP -1) IS ACTIVATED, AFTER PROOF OF OPERATION, THE BOILER COMES ON. HOT WATER IS DIVERTED INTO THE PRIMARY LOOP VIA THE 3 -WAY MIXING VALVE (CV -1), AND THE SECONDARY PUMP. THE BOILER SHALL MAINTAIN ITS OUTLET TEMPERATURE SETTING. INITIAL SETTING SHALL BE 180 DEG. F. TO PROTECT AGAINST SHOCKING THE BOILER MAINTAIN A MINIMUM 140 DEG. F RETURN WATER TEMPERATURE TO THE BOILER. . SECONDABLY_Ille THE SECONDARY LOOP TEMPERATURE SHALL BE RESET BY THE CMCS SYSTEM BASED ON THE OUTSIDE AIR TEMPERATURE. WHEN THE OUTSIDE AIR TEMPERATURE IS 35 DEG. F., THE LOOP TEMPERATURE SHALL BE MAINTAINED AT 160 DEG. F.. TEMPERATURES THAT LIE IN BETWEEN THESE VALUES SHALL BE LINEARLY PROPORTIONAL. • 1D / LAG CONTROL' THE PRIMARY AND SECONDARY PUMPS SHALL BE ON A LEAD /LAG PROGRAM WITH EACH PUMP RINNNINNG AT ONE WEEK INTERVALS. TOTAL RUN TIMES FOR EACH PUMP SHALL BE DISPLAYED ON THE WATER SYSTEM GRAPHICS. OVERRIDE CAPABILITIES SHALL BE PROVIDED TO ENABLE ANY PUMP AT THE BUILDING OPERATORS INTERFACE. ain i rn WATER SYSTEM THE CHILLED WATER SYSTEM PROVIDES CHILLED WATER FOR USE IN THE SOUTH BASE FACILITY MAINTENANCE BUILDING SPACE CHILLED WATER SYSTEM. THE SPACE COOLING SYSTEM INCLUDES THE +FOLLOWING EQUIPMENT' CHILLER (CHLR -1) CIRCULATION PUMPS (CHWP -1 L CHWP -1A) AHU-1 THE CHILLED WATER SYSTEM SHALL BE CONTROLLED BY THE EXISTING CMCS (COMPUTER MONITOR AND CONTROL SYSTEM). •MORNING COO. DOWN( THE CHILLER IS ENABLED WHEN THE OUTSIDE TEMPERATURE IS 67 DEG. FOR MORE. THE PRIMARY AND THE SECONDARY LEAD PUMPS ARE ENABLED AND PROOFED BEFORE THE CHILLER IS ACTIVATED AT 530 AM FOR MORNING COOL DOWN. (THIS TO BE TIMED WITH THE START UP OF AHU -1). THE TEMPERATURE OF THE LOOPS SHALL FOLLOW THE NORMAL OPERATION LINEAR SLOPE TEMPERATURE MODULATION. NORMAL OPERATION 1 THE CHILLER SYSTEM ( PRIMARY, SECONDARY PUMPS, AND CHILLER) SHALL BE ENABLED IF THE OUTSIDE : TEMPERATURE IS 67 DEG. F OR MORE, OR IF ANY SPACE TEMPERATURE EXCEEDS ITS COOLING SETPOINT 1 (78 DEG. F) AND CANNOT BE SATISFIED BY THE AHU ECONOMIZER DAMPERS USE OF OUTSIDE AIR. THE CHILLER SETPOINT SHALL BE MODULATED BY THE CMCS SYSTEM TO THE CHILLER TO PROVIDE OPTIMAL SYSTEM CONTROL. FOR INITIAL SETUP, PROVIDE LINEAR TEMPERATURE MODULATION OF THE PRIMARY LOOP AS 43 DEG. F CHILLED WATER AT 85 DEG. F. OUTSIDE TEMPERATURE, AND 55 DEG. F. CHILLED WATER AT 67 DEG. F OUTSIDE TEMPERATURE. NIGHT STBACKI NIGHT SETBACK SHALL DISABLE THE CHILLER, BOILER, THE PRIMARY, AND SECONDARY PUMPS AT 530 PM. THIS VALUE TO BE RESETTABLE. THE SYSTEMS SHALL BE OVERRIDDEN VIA THE RESET SYSTEM IF 50Z OF THE SPACE TEMPERATURES FALL BELOW 55 DEG. F. OR ABOVE 80 DEG. F. DURING THE OVERRIDE MODE, EITHER COOLING OR HEATING SYSTEMS SHALL COME ON AS REQUIRED TO MAINTAIN 50X OF THE SPACE TEMPERATURES THAT FALL BELOW 55 DEG. F. OR RISE ABOVE 80 DEG F. THE SYSTEM IN NEED SHALL BE ENABLED TO MAINTAIN 50X OF THE THERMOSTATS AT SETPOINT FOR 30 MINUTES. IN EITHER CASE (COOLING OR HEATING). THUS THE CHILLED OR THE HOT WATER SYSTEM SHALL FOLLOW THE NORMAL OPERATION WATER TEMPERATURE SETPOINTS. THE AIR HANDLERS SHALL BE ENABLED TO PROVIDE THE PROPER AIR DISTRIBUTION. ONCE THE 30 MINUTES IS UP, THE SYSTEM SHALL GO BACK TO THE NIGHT SETBACK MODE.. MORtiiiicL.WEELAWOLAniti THE BOILER, THE CHILLER, PRIMARY AND SECONDARY PUMPS SHALL BE COMMANDED ON AT 530 AM FOR MORNING WARM UP OR COO. DOWN. THIS MODE IS REQUIRED TO PROVIDE CONDITIONED AIR TO THE SPACE TO REMOVE STAGNANT AIR, AND GET THE BUILDING READY FOR THE OCCUPANTS. THIS MODE TO $E MAINTAINED FOR 30 MINUTES, THEN THE SYSTEM SHALL FOLLOW NORMAL OPERATION. LEAD / LAG CONTRA THE SECONDARY PUMPS SHALL BE ON A LEAD /LAG PROGRAM WITH EACH PUMP RUNNING AT ONE WEEK INTERVALS. TOTAL RUN TIMES FOR EACH PUMP SHALL BE DISPLAYED ON THE WATER SYSTEM GRAPHICS. OVERRIDE CAPABILITIES SHALL BE PROVIDED TO ENABLE THE SECONDARY PUMP AT THE BUILDING OPERATORS INTERFACE. THE CONTROL. SET POINTS GIVEN ARE FOR THE INITIAL SYSTEM SET -UP. ALL SET POINTS FOR THIS SYSTEM SHALL BE RESETTABLE VIA THE INTERACTIVE COMPUTER SCREEN LOCATED IN THE BUILDING OPERATING ROOM. EXISTING CONTROL SOFTWARE SHALL BE PROGRAMMED TO INDICATE SET POINTS ON THE SYSTEM GRAPHICS DEPICTING THE CHILLED WATER AND THE HEATING 140T WATER SYSTEMS. Xing County Deportment of Transportation METRO TRANSIT DIVISION SOUTH BASE — WEST SOUTH FACILITIES HVAC UPGRADE PROJECT 'CONTROL DIAGRAM .::....:.: ��.:.....�1:�.:,:..:.�: �'...•...:.5 -. ,,...fi _ 514 t . ? • . yid iZ.c.i�Qin +.1i... DATE: JAN 2004 DRANrNNG NO: 1.46.03 SW NO: OF 21 27 4 COIL SCHE DULE HEATING HOTWATER EQUIP NO M EAT T LAT T ,,,, M 'F LWT T REMARKS „H C -1 515 0 80 1.1 160 140 }. HC -2A . 635 60 GPM 1.4 160 140 AS -BUILT CONDITIONS HC -2B 635 60 80 1. - 160 140 \ ; HC -3 1570 60 80 ,3.4 16 I 140 110 HC -4 1820 60 80 3.9 160 140 14,100 HC -5 2060 60 80 4.4 160 140 24.3 HC -6A 1505 60 80 3.3 160 140 HC -6B 2280 60 80 4.9 160 140 HC -7 • 3040 60 80 6.6 160 140 ', U H 1200 60 80 2.0 160 140 AIR HAND R SCHEDULE L� EQUIP NO OPERATING CONDITIONS SUPPLY FAN , EXHAUST FAN , HOT WATER COIL REMARKS CFM TSP RPM BHP MHP CFM TSP RPM BHP MHP CFM FAT F LAT F GPM EWT F LWT °F AHU -2 AS -BUILT CONDITIONS 19,885 3.2 1 150 13.1 15 14,100 1.7 990 8.9 10 19,885 52.6 60 18.2 130 110 NEW CONDITIONS 15,025 1.8 870 6.2 15 14,100 1.7 990 8.9 10 15,025 45 60 24.3 160 140 AIR SEPARATOR SCHEDULE I EQUIP NO SERVICE INLET /OUTLET SIZE (IN) MAXIMUM OPERATING TEMPERATURE & PRESSURE (DEG F /PSIG) MAXIMUM CAPACITY (GPM) DIMENSIONS BASIS OF DESIGN AS -1 CHILLED WATER SYSTEM 2 375/125 80 8 -5/8" DIA X 18" H • MANUF TACO, MODEL AC2F AS -2 I HOT WATER SYSTEM 3 375/125 190 12 -3/4" DIA X 24-1/4" H MANUF TACO, MODEL AC3F PUMP SCHEDULE CHILLER SCHEDULE EQUIP TYPE CAPACITY (TONS) REFRIGERANT GPM EWT ' F LWT 'F HEAT EXCHANGER WATER SIDE MAX PRESSURE DROP (FT) EER COP FAN (KW) COMPRESSOR (KW) ELECTRICAL (V /PH /HZ) r BASIS OF DESIGN WEIGHT (LBS) CHLR -1 PACKAGE AIR-TO-WATER 18.2 R -407c 43.7 55 45 9.0 9.7 2.84 2.56 19.96 460/3/60 MANUF PETRA MODEL RWC210N4 1300 PUMP SCHEDULE EQUIP NO SERVICE TYPE CAPACITY TDH (FT) RPM RPM MOTOR HP ELECTRICAL (V /PH /HZ) BASIS OF DESIGN PP -1 PRIMARY HTG WATER LOOP IN -LINE 60 20 1 750 3/4 460/3/60 MANUF TACO, MDL 1935 PP -1A PRIMARY HTG WATER LOOP IN -LINE 60 20 1750 3/4 460/3/60 MANUF TACO, MDL 1935 CONTROL VALVE SCHEDULE EQUIP NO - TYPE LINE SIZE (IN) GPM CV STEM STROKE VALVE BODY a ACTUATOR BASIS OF DESIGN CV -1 3 -WAY MIXING VALVE 2" 60 26.8 - - ELECTRIC MANUF SIEMENS OUTSIDE AIR INTAKE SCHEDULE EQUIP NO SERVICE TYPE CFM SQ FT AREA FPM PRESSURE LOSS IN WC BASIS OF DESIGN OAI -1 AHU -1 MUSHROOM 8500 [ VELOCITY 8.5 990 0.15 MANUF PENN, MODEL AIRETTE No. NOTE: CHILLED WATER FLUID: 30% SOLUTION BY VOLUME OF ETHYLENE GLYCOL AND WATER. NOTE: 1. RE-SHIEVE SUPPLY FAN AND BALANCE AHU -2 TO CONDITIONS PER SCHEDULE 2. VERIFY EXHAUST FAN CONDITIONS REVISION sr sr or eir =mod BY I I nPP'o DATE YI ocPwcs 1 nnl R NICHOLS DRAWN: B HAMBLIN CHECKED: J TURNER V " RECOMMENDED: D CRIPPEN 6416L PROJECT MANAGER: G STRONKS �� I APPROVED: 8 ISLER 16IS NO: 432620 WORK IEOUEST: 021 -01 CONTRACT NO: C33143C iJor ■ )¼// ,'� r s Ir.]) Pyle_ 13 ez. ethic- /AA. er---Aezc i y NONE ONE INCH AT FULL SIZE Y IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION No: X51 • King County Department of I Transportation METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT EQUIPMENT SCHEDULES RECEIVED OCT 2 7 2084 MIT CENTER DRAWING No: 146.04 (Am JAN 2004 SHEET NO: OF 22 27 1 aI- E a REVISION 4 �...._.. ELECTRICAL 1 ion BY APP'D DATE TO MCC -1 BELOW (SEE E1.02) MEZZANINE 1 /2 "EM T [1081 SF -7 MCC -1(2) EF -1 MCC -1(5) PP -1 MCC -1(14) PP -2 MCC -1(15) (SEE NOTE 1) • • DESIGNED: J PELMAN �� AMI4: V BEACH aEacEC: C REYNOl.6S REcawtrOEO: D. CRIPPEN PROJECT MANAGER: G. STRONKS APPROVED: B. ISLER e I IBIS NO: 432620 WORK MUM 02T - 07 )c CONTRACT NO: I C33143C SCALE: Q " =1' f'� 3/8 - 0 " ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY soh LOCATION NO: #51 P • King County Department of Transportation NOTES: VvMA 3/4" FLEXIBLE METAL CONDUIT r v. 1. EXISTING PUMPS PP -1 AND PP -2 TO BE REMOVED. REMOVE ALL ASSOCIATED HARDWARE. REMOVE WIRE BACK TO MCC -1 CIRCUITS 14 AND 15. PROTECT WIRE AND CONDUIT ASSOCIATED WITH SF -1 AND EF -1. (SHARED CONDUIT). LEGENQ: //� EQUIPMENT TO BE REMOVED. COORDINATE / WITH MECHANICAL CONTRACTOR. Nbliti 18? .... s... - .�...�w. -444. r.A.. `:.:.a; .;....x+d:I'` `.l4tw'.0'` METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT SEPARATE MEZZANINE PERM NO DEMOLITION RE 6.7 PLAN I F. crr OF Tug OCT 272084 PERP T CENTER DRAWING NO: E1.01 V T DATA JAN 2004 SHEET NO: OF 23 27 1 DUST COLLECTOR 1112 i i P2-010 I. CARPENTER'S SHOP CARPENTER'S SHOP � „3 BY APP'D DATE i IIMMP or P2— C10(25,27) OIL PUMP Al TO BE RE ALL ASSOCIA CONDUIT TO D UNIT HEATER vI OVED. REMOVE TED HARDWARE, A ND WIRE BACK PANEL P2 -C10. • FINAL ASSEMBLY FIRST AID 05_1 OFFICE 11041 I. ANITOR 1061 - 1 _ INSTALL NEW 120 -24VAC 60HZ CONTROL POWER TRANSFORMER FOR CONTROL VALVE CV -1. (SEE M6.04) INSTALL CONDUIT AND HARE TO PANEL P2 -C7 (31) P4 --07 -2 P2 —C7 MULLION STAGING & SUB- ASSEMBLY STORAGE 1 PROJECT MANAGER: G. STRONKS APPROVED: B. ISLER 19IS NO: 432620 VIC* 02T -07 WALL PANEL STORAGE & SUB- ASSEMBLY B 1 11091 I Rio 1 MECHANICAL JUNCTION PANEL 1081 L_ MCC -1 (14.15) SCALE: 3/16 " =1 - O " ONE INCH AT FULL SIZE ELECTRICAL 1 107 1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: #51 r - I I a• as BOILE i (1) 1-1/4" EXISTING E41T TO CHILLER ON ROOF (1) 3/4" EXISTING EMT TO CHILLER CONTROL SWITCH ON R OF SEE E1.03 King County Department of Transportation r. NEW PUMPS PP -1 AND PP-1A. MOUNT DISCONNECTS ON UNI$TRUT FRAME. LEGEND: ,// EQUIPMENT TO BE REMOVED. COORDINATE 7 / WITH MECHANICAL CONTRACTOR. v'W'/ 3/4" FLEXIBLE METAL CONDUIT METRO TRANSIT DIVISION SOUTH BASE — WEST SOUTH FACILITIES HVAC UPGRADE PROJECT FIRST FLOOR PLAN SEPARATE MIND I ) P6lMQT APPROVAL • i...._roar,. •••,••• •y .•.'.V.... AIM.• v.• ,fir.. ."�M•Mr. i.^MM.AN. . *ts' • M++ir �OF Tu to OCT 2 72614 POINT maw DATE: JAN 2004 DRAWING NO: E1 .02 SHEET NO: OF 24 27 No. EXISTING HP /CRIB -1 TO BE REMOVED. REMOVE AND SALVAGE ALL ASSOCIATED ELECTRICAL HARDWARE. REVISION • Vier A al.e/rAreee, Ad. 1 4 •'"ArAw • A • i 1 1 BY APP'D DATE P4 -C7 -2 (2,4,6) P2 -C7 / �/ .r'i / 4,4r AI (2) #12 AWG nHWN (1) #nz GND 3/4 GRS SEE NOTE 2 WATERPROOF SEAL WALL PENETRATION DEMO ROOF PLAN SCALE: 1/4" = 1' -0" i WP NEW ROOF PLAN SCALE: 1/4" = 1' -0" wP GFCI P4 -C7 -2 (8,10.12) P4 -C7 -2 P2 -C7 0,12 (8,1 ) v 2 -C7 ( 33) (3) #6 AWG THWN (1) X10 AWG GND � GRS SEE NOTE 2 EXISTING HP /CHLR -2 TO BE REMOVED AND REDUCED WITH NEW CHILLER SEE NOTE 1 NEW CHILLER SEE NOTE 1 RELOCATE EXISTING DISCONNECT . REC ECT TO EXISTING CIRCUIT. WALL MOUNTED. SEE SECTION 1/E5.01 RELOCATE EXISTING FUSED DISCONNECT. RECONNECT TO EXISTING CIRCUIT. EXPIIIIIs 3/7/0 S • DESIGNED: J PELb1AN7# DRAM: V BEACH CHECKED: C REYN BI.'1`JS RE : D. CRIPPEN )6 PROJECT MANAGER: G. STRONKS APPROVED: B. ISLER IBIS N0: 432620 WORK =UM 02T -07 CONTRACT N0: C33143C t:. SCALE: 11/4"=r-0" ONE INCH AT FULL SIZE t' IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: #51 NOTES: EGEND: King County Department of Transportation // / EQUIPMENT TO BE REMOVED. COORDINATE / WITH MECHANICAL CONTRACTOR. 1. CAP AND ABANDON EXISTING CHILLER STUB -UPS. 2. WALL PENETRATIONS AND ALL ROOF CONDUIT TO BE GRS. CONNECT TO EXISTING EMT IN THE STORAGE BAY. REPLACE POWER CIRCUIT FROM P4 -C7 -2 WITH #6 AWG CONDUCTORS. 1 METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACIILITIES HVAC UPGRADE PROJECT SEPARATE REQ paw No ROOF PLAN .....+..«..- ,..r.,w....y.4i►.4o- 1 «�.+F..taf:JNMi+ '1�.i ice' ��:.oi.. . r: . 0 ti RECEIVED CITY OF KVwiu OCT 27 204 PERMIT MIMI 4 DATE: JAN 2004 DRAWING N0: E1.03 9IEET NO: OF 25 27 ROOF SURFACE // REVISION 0 BY CHILLER APP'D DATE FOAM AND FRAMING CHANNEL CONDUIT SUPPORT (TYP) 1/2" THICK WALKWAY PAD CHILLER INSTALLATION CONDULETS OR HUBS AS SUITABLE SECTION SCALE: NONE E1.03 INSTALL SNATCH 4 1/2' ABOVE ROOF SURFACE /X/ / INSTALL NEW WEATHER —PROOF BOX WITH 15A GFq RECEPTACLE TO CKT P2 —C7 (33). GALVANIZED RIGID STEEL CONDUITS DISCONNECT SWITCH PROTECT CONDUIT AT WALKWAY WITH RAMP PER SECTION 2, THIS SHEET. P2-C7 (33) STORAGE BAY . P4-C7-2 (8.10.12) • AL 1 � Is SEAL WALL PENETRATOIN (TIP) DESIGNED: J PELMAN V BEACH CHECKED: C R 5 RECOMMENDED: 0. CRIPPEN PROJECT MANAGER: G. STRONKS APPROVED: 81 B. ISLER 1915 NO: 432620 SON waist 021 -07 CONTRACT NO: C33143C FIRESTONE RUBBER WALKPAD SCALE: NOTED ONE INCH AT FULL SIZE M ' IF NOT ONE INCH, SCALE ACCORDINGLY STE LOCATION NO: #51 King County Department of Transportation WALK WAY RAMP SECTION SCALE: NONE E1.03 F1oU I�9 PRESSURE TREATED LUMBER METRO TRANSIT DIVISIO `''ti SOUTH BASE - WEST SOUTH FACILITIES HVAC UPGRADE PROJECT ELECTRICAL DETAILS sami PERAf CONDUIT FOAM AND FRAMING CHANNEL CONDUIT SUPPORT crr RECEIVED TuKw►u OCT 2 7 2004 Peres DRAWING NO: E5.01 DATE: JAN 2004 SHEET NO: OF 26 27 .M' OROJIT FRAMES a AMPS FRAMES a AMPS WIRE SZE DESCRIPTION HP AMPERAGE LOCATION a b c 1 a ,_ 20A / 1P b T 112 RECEPTACLES la .. �� 20A / 1 P ROOM 146 3b 20A / 1P 812 SPEAKER SYSTDA RECEPTACLE � ... ELECTRICAL ROOM Sc 20A / 1P 112 b 812 ADT PANEL RbCEFTACIE t:.: 6 ELECTRICAL FAA 7a 20A / 1P Sc 012 UG TS IN CAGE 012 m .,, w , ' ,;•,r ; ROOM 142 96 20A / 1P 812 HWCR1 1/4 5.8 ' . ., ROOM 11c 20A / 1P 012 CArFP AIR COMPRESSOR 019 1/4 . 5.8 STORIES 13a 1 012 ,RECEFTACLES P TACLES 3.1 •,..•1t , . 15b 20A / 3P (3)112 POWER DOOR 3/4 3.1 . _ :. ROOM 142 17c 1 1 13a 20A 1 1P " • 3.1 19a 20A / 1P 612 PHCTOO SENSOR CONTRA 156 _ 2 C•C >LV ROOF 216 20A / 1P . #12 RJG POLE AND SKIN UGHTlNG ,� 6.25 ROOMS 144. 145 OUTSIDE 23c 20A / 1P 012 012 FLAMMABLE STORAGE BUILDING . fK� 25a 20A / 1P 19a 112 RECEPTAOES 112 „ ; ; OUTSIDE NW 276 20A / 1 P 112 RECEPTACLES 216 ,,r . _ OUTSIDE 29c 20A / 1P 012 RECEPTACLES • , ; ice 6 acuANINE 31a , 20A / 1P 112 0 12 CHILLED WATER CONTROL ' 2 .: ,,....* i ,, ROOF 33b 20A / 1P 25a 012 CHILLER RECEPTACLE - 5:` ROOF 35c 2 / 1 P l 012 RECEPTACLES 27b , . t'. < 20A / 1 P MEZZANINE 37a 20A / 1 P , 112 LIGHTS LIGHTS AHU•3 3 ' ,,,. , , : ROOF 36b 20A / 1P , - 012 BOILER CONTROL • ., - 5.8 ,• -..,.m MECHANICAL ROOM 41c 20A / 1P 012 BURNER MOTOR 1/4 • _ + , 5.8 ROOM 143 , ; 2a 4 b 20A / 2P 4.. 12) 012 AIR DRYER D-1 314 7.9 .; ' • - '• - . MECHANICAL FK3>M I r.':l -:. '- �.1•JMA/ ". rK !'. 1•N 'if �►•fl .y 7.9 8: 20A / 2P (2) 812 AIR DRYER D12 l :.. 3/4; , , ? • w . 7.9 MECHANICAL RC>OM r 106 20A 1 1P t 12 DOC CONTROL PANEL :' : 4.2 ' ......... MECHANICAL ROOM 12c 20A / 1P #12 UG HT1N G CONTACTOR CLOCK .: , _:: � __ .,. ELECTRICAL ROOM 14a I 3.1 16b 20A / 3P 13)112 W POWER DOOR a/4 . , , • 3.1 ROOM 46 1k I 1 , 4b I • pH 612 POWER DOOR • 20a i 3.1 _ , ROOM 136 6c .�► I i 22b 20A / 3P (3)112 E PLOWER DOOR 314 , j . .. ; 3.1 . ROOM 46 1 i 3.1 .. . . 3.1 26a 20A / 1 P 20A / 3P #12 RECEPTACLES 3/4 6 :• ..:,,.� , .,.• 130.142148 28b 20A / 1P 12c 012 RECEPTOD.ES ... 6 '` 136- 142.146 30c 20A / 1P 3.1 012 RECEPTACLES .� . . . 6 130142,146 32a 20A / 1P ' 012 RECEPTACLES 4.5 : ,.,i... , 143.143A 34b 20A / 1P � . 112 • UNIT HEATER 1/8 ' , : 3 .,�.� ROOM 146 36c 20A / 1P _ 012 IRRIGATION CONTROL PANEL , *., ,� ' ' 3 ROOM 143 38a 20A / 1P 20A/ 1P 012 POWER PAINT CONTAINER 1/8 . . . • *b 2011 / 1P 226 112 AC TEST RECEPTACLE 012 1 / 8 . . . A 3 42c 20A / 1P ROOM 137 012 AC TEST RECEPTACLE 20A / 1P T 1/8 CIRCUIT FRAMES a AMPS WIRE SIZE DESCRIPTION HP AMPERAGE LOCATION a b c la 20A / 1 P • 12 RECEPTACLES 8 ` , - ROOM 136 3b 20A / 1 P 112 RECEPTACLES 6 • ROOM 136 Sc 204► / 1P 012 RECEPTACLES _ ., ,,.*.�, 4wrtr 8 ROOM 138 7a 20A/ 1P 012 6 - , . -�,�,` I ROOM 137 9b , 20A / 1P 012 ,RECEFTACLES P TACLES 6 , . ROOM 137 11c 20A / 1P 012 O UGHTS �REEc AND POWER f� « . �....... '... sf: LANDSCAPER CONTAIN. 13a 20A 1 1P 012 RECEPTACLES 6 r . ,_,•,;... f �.. ROOMS 144. 145 156 20A / 1 P 012 RECEPTACLES . 6 ,� ROOMS 144. 145 17c 20A / 1P 012 COI.LECT�OR, . fK� 5.8 19a 20A / 1P 112 _SAWDUST DUST MILL. DAMPERS / FtAMD(SYS 5•8 :- ...;.,,.. • . 216 2 / 1 P 1 112 SANDER A _ , 23c 20A / 1P 112 SANDER ' i. r 25a 20A / 1P , - SPARE .•, 27b 20A / 1 P - SPARE , ,,.,; 2 9 c 20A / 1 P , - SPARE • ., ' - nu. 4 dl y . .I4.10 4-,t ..lr' " - -i. •' t..t<•.•' . •f'd . +_. ... .. r.':l -:. '- �.1•JMA/ ". rK !'. 1•N 'if �►•fl .y I 3.1 , � , 4b I 20A / 3P pH 612 POWER DOOR 3/4 . 3.1 _ , ROOM 136 6c I i '1►► 3.1 Ila 1 i 3.1 .. . . 106 20A / 3P (3) 012 PCIINER DOOR 3/4 : -_. 3.1 . ROOM 137 12c '` 3.1 14a I 6.2 ' I� 16b 20A / 3P (3)612 POWER DOOR (213/4 � . :: 6.2 ' ' , : ROOMS 144. 146 18c I _ . , 6.2 1 20a 20A/ 1P 112 UNIT HEATER 1/8 3 * ROOM 136 226 20A / 1P 012 1 / 8 . . . . . _ ., 3 .• .. ROOM 137 UNIT H E A T E R f 24c 20A / 1P 112 UNIT HEATER 1/8 • :.' , -.41,. 3 ROOM 145 26a I , - , - • 28b 40A / 3P PANEL 'P2' SUBFEED SHED 30c 1 i. sc+1,P.t. - .+ �.. sF;: rr g•r Ca .r 141rf ,r..• j II . r7...4. 1� • 1•�`Ti1•.�1 -. t': 67w, .s , ,crT, .. i c . r ,,l :1c•. ` -': ,u< • fi or -ad • • .. '�. r il WY• teA,C. %. G: x Air • :Iwo. p A • � E[ InitL., , a . ........... ear L r1M.,:-., u. -6 -1 m.:: :O.�w l •,: • 1 , • _ M .IYO� � l Ef. ••1%, •..TN . S , ■ DEMAND kVA= CONNECTED kVA 38.0 33.4 27.0 TOTAL AMPS w•� PANEL P2-C'7 BLDG TYPE SURFACE o RUSH • MAIN SKR. RATING REF. DWG NON REVISION(s) AS BUILT (MFD) EN JS PE LMAN (206. 263.3713) DEMAND kVA= SURFACE MLO 225A, 120Y7108V• 3PH, 4W OCINNECTED kVA REMOVE CIRCUITS, RELABLE AS INDICATED MODIFIED CIRCUITS REPLACE CIRCUIT BREAKER WITH 60AMP /3 POLE BREAKER RATED FOR USE WITH HVAC EQUIPMENT NOTES: FM ELECTRICAL PANEL SCHEXLE CASE S8•ANNEX DATE LOCATION ROOM 143A ELECTRICAL ROOM FEEDERS (4) 01, /BOND FROM PANEL • MD2 -1 OCT 5 SHORT Oct. RTt'i , Isiym REVISED OCT DATE REVISED JOB NO. 1. ALL CIRCUITS WHERE EQUIPMENT HAS BEEN REMOVED, AND NO NEW EQUIPMENT IS INSTALLED UNDER THIS CONTRACT, SHALL BE MARKED AS "SPARE" ON THE PANEL SCHEDULE AND LEFT IN THE OFF POSITION. 2. REPLACE OL RELAY HEATER PER NEW 3 /4HP MOTOR NAMEPLATE CURRENT. REVISION BY 0 I 42.6 53.31 48.8 I TOTAL AMPS T MEASURED LOAD APP'D DATE 21 -Jan -04 PANEL P2410 BLDG FM TYPE . D KOCB (30438 -2) SURFACE or RUSH ' SURFACE MAIN BKR ' M LO RATING ' 225A,120Y/20BV, 3PH. 4W R. DWG NO(s) REVISION(s) AS BUILT (MFD) ENGINEER JS PE LMAN 1206. 263.371 f i L MCC-1 4 I- FLECTRI CAL PANEL SCHEDULE SASE SB -ANNEX DATE CV LOCATION ROOM 136 CARPENTER SHOP FEEDERS (4) 01. •BON FROM PANEL 'MD2 -1' 'KT 6 SHORT CKT• R1 . Ism REVISED OCT DATE REVISED JOB NO. As OL OL OL OL OL L- W MEASURED LOAD I EXPIRES 3/7/K 6- Aug-03 Irmo �C 4b 6c 10b O 12c 14a N S D. CRIPPEN PANEL P4 -C7-2 BLDG F M TYPE . 1- LINE [ H CN2365.6) SURFACE CO FLUSH+ • FA CE MAIN SKR. M LO RATING 200A, 277Y/460V, 3PH, 4W R. DWQ NO(s) REVISION(s) AS BUILT (MFD) • ENGINEER J S PE LMAN (206. 263 -3713) FRAMES WIRE ORCUrr a AMPS SIZE 7a 1 9b 11c 13a 156 17e 21b 23c 25a 276 29c wow) - •' • ► \ 1a 1 3b _ 70A / 3P Sc 70A / 3P 19a / / / / / ► ' - i : ; • ONE -LINE DIAGRAM • / - 2a to lab 18c 204 226 24c 26a 286 M • iia+ir.4.4.. 10 60A / 3P 1 1 _ 06 .60A / 3P 06 CHILLER 1 06 20A / 3P 012 I _ .1 - / / APPROVED: B. ISLER / - DEMAND kVA= CONNECTED kVA 600A, 480V, 3PH, 60HZ BUS (22,000 A BUS BRACING, 15,100 RMS SYM AMP AVAILABLE) 11 12 OL OL OL OL OL PROJECT MANAGER: G. STRONKS ISIS NO: 432620 1r0* IEOLRl: 02T - . t� ELECTRICAL PANEL SCHEDULE BASE SB•ANNEX DATE LOCATION MECHANICAL ROOM FEEDERS DESCRIPTION AIR COMPRESSOR AIR COMPRESSOR 810 .AHU -3 AIR HANDUN G UNIT SPARE SCALE: EMPTY EMPTY EMPTY EMPTY EMPTY EM 1I • BATTERY CHAF1GER // DOOR DAPTY DAFT( EMPTY EMPTY EMPTY s ..ter 1, . . a' ' .. ., k• e _ rt . ., • 14 NONE C33143C . � SIX LOCATION 144 0,1..4. CONTRACT NO: SIZE LOCATION NO: )15/M ) 3/M ) 3/M )15 /M ) 3/M )15/M )15/M ) 7/M � 3/M ) 3/M ) 3/M ) 3/M ) 3/M ) 3/ _I, I, I 11 ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY REVISED OCT. DATE REVISED JOB NO. 1 SHORT CKT. RTC , It>llm FROM PANEL 'MD4 -1' 18.6 ' 5. 7.5 ' ' - 18.6 15 ` 16 HP a b c I v 7 `4 27. 20 •:° , ' • 27 r AMPERAGE 27 ,t r - . •• 46.1 �.�•� 46.1 3 _._ 121.7 121.7 King County Department of Transportation *a EMPTY MECHANICAL ROOM 27 17 18 PREPARED SURFACE FOR FUTURE MECHANICAL ROOM 27 18.6 LOCATION ROOF • ROOF ROOM 146 121.7 TOTAL AMPS MEASURED LOAD 6 -Jan -04 ...ec :f ly H4671.11.44 e 10 Ad. r{}K.rJr.']•7r'I'- rip •n• . - . • •. Con fc "v- wf:4:.. n•-' - `.*:*" ,a c ,a,s.c14 ".t f a•..•+:• T tilt -' 13 1\1 04. METRO TRANSIT DIVISION SOUTH BASE - WEST SOUTH FACIILITIES HVAC UPGRADE PROJECT SEPARATE PERl�I AID APPI�O�VR K SCHEDULES & ONE-LINE DIAGRAM' !• RECENED CITY OF TUKWILA OCT 272H PERMIT CENTER DATE: JAN 2004 DRAWING NO: E6.01 SHEET NO: OF 27 27 •:•71 +.•f14- :7"•Jr'••4•A' ,,,,,,.., • . " •;- r- ttt!' ....,4..e NI•i 4 S•'T;