HomeMy WebLinkAboutPermit M04-198 - HOME FURNITURE.7855 SOUTHCENTER PY
•
•
lit 7 d IS
lea'
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
3523049107
17855 SOUTHCENTER PY TUKW
Contact Person:
Name: 3OHN WARE
Address: 4210 B ST NW, SUITE F, AUBURN, WA
Contractor:
Name: FIVE STAR MECHANICAL
Address: 3902 W VALLEY HY STE 200, AUBURN WA
Contractor License No: FIVESM *010JT
DESCRIPTION OF WORK:
REMOVE AND REPLACE SIX (6) EXISTING ROOF TOP HVAC UNITS. ALL NEW UNITS ARE
LIGHTER THAN OLD UNITS.
Value of Mechanical: $46,950.00
Type of Fire Protection:
doc: IMC- Permit
Cit y 0 Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: ci.tukwila.wa.us
HOME FURNITURE
17855 SOUTHCENTER PY, TUKWILA WA
Furnace: <100K BTU 0
>100K BTU 0
Floor Furnace 0
Suspended /Wall /Floor Mounted Heater 0
Appliance Vent 0
Repair or Addition to Heat/Refrig /Cooling System.... 6
Air Handling Unit <10,000 CFM 0
>10,000 CFM 0
Evaporator Cooler 0
Ventilation Fan connected to single duct 0
Ventilation System 0
Hood and Duct 0
Incinerator: Domestic 0
Commercial /Industrial 0
MECHANICAL PERMIT
3AM ASSOC I /3BM ASSOC I
C/O JEFFREY A MORRIS GRP, 2500 SAND HILL RD #240
EQUIPMENT TYPE AND QUANTITY
* *continued on next page **
M04 -198
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 786 -8278
Phone: 253- 833 -8284
Expiration Date:04 /30/2006
Steven M. Mullet, Mayor
Steve Lancaster, Director
M04 -198
12/13/2004
06/11/2005
Fees Collected: $726.00
International Mechanical Code Edition: 2003
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP/1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood /Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 12 -13 -2004
Permit Center Authorized Signature:
Signature:
doc: IMC- Permit
Cit y o Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: ci.tukwila.wa.us
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: M04 -198
Issue Date: 12/13/2004
Permit Expires On: 06/11/2005
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local Taws
regulating const ioa he performance of work. I am authorized to sign and obtain this mechanical permit.
-, 7t Date: 1 - 13-
Print Name: � C� - Ztj
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
M04 -198 Printed: 12 -13 -2004
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
Parcel No.: 3523049107 Permit Number: M04-198
Address: 17855 SOUTHCENTER PY TUKW Status: ISSUED
Suite No: Applied Date: 11/04/2004
Tenant: HOME FURNITURE Issue Date: 12/13/2004
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: Readily accessible access to roof mounted equipment is required.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
9: ** *FIRE DEPARTMENT CONDITIONS * **
10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
12: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
13: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
doc: Conditions
M04 -198 Printed: 12 -13 -2004
104.2)
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
16: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and
the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051)
17: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Conditions
* *continued on next page **
M04 -198 Printed: 12 -13 -2004
Signatu
Print Name:
doc: Conditions
fl
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any
regulating construction or the performance of work.
4,7
Date: /2--/-
of law and ordinances
other work or local laws
M04 -198 Printed: 12 -13 -2004
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Building Permit No.
Mechanical Permit No. �G
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: -7 5 ✓ 5 Sou - iCe
Tenant Name: RAbtu 144
Property Owners Name: pw-� pkl^ Lc.C.Iti
King Co Assessor's Tax No.: S,joZ .3o '' ?1e'7
Suite Number: Floor:
New Tenant: ❑ .... Yes g. No
Mailing Address:
City
State
Zip
CONTACT PERSON
Name: ,..)01 1 \A.)are_
Day Telephone:
Mailing Address: 2-6 6-- 784 — S,
City
E -Mail Address: Fax Number:
Company Name: F \,»_-
Mailing Address:
\permits plus'icc changes \permit application (7.2104)
State
Zip
GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page)
Of
City /
Day Telephone: 06 - 7P - R2 7a
E -Mail Address: V e •eC/ . (c Fax Number: 5 3— Pa 2— i 2/5
,�^ /
Contractor Registration Number: F 1 n %.i _ S l'n 9 -(5 / P 3 Expiration Date: l�tpb, 2 3 ,2a3CS
L
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Contact Person: O ) a r
Page 1
State Zip
ARCHITECT :OF R - All plans: must be wet stamped by Architect of Record
Company Name:
Mailing Address:
State
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
ENGINEER OF RECORD -. All plans must be wet stamped by Engineer of Record
Company Name: /0 i —
Mailing Address:
State
Zip
Zip
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
L BUILDING . PERMIT INFORMA''"tON - 206 - 431 -3670
Valuation of Project (contractor's bid price): $ Existing Building Valuation: $
Scope of Work (please provide detailed information):
Will there be new rack storage? ❑ ..Yes ❑.. No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ .. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No
If "yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
\permits pltu\icc changes\permit application (7.2000)
Page 2
Existing
Interior
Remodel
Addition to
Existing
Structure
New
Type of
Construction
per IBC
Type of
Occupancy per
IBC
l" Floor
2n Floor
3r Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
L BUILDING . PERMIT INFORMA''"tON - 206 - 431 -3670
Valuation of Project (contractor's bid price): $ Existing Building Valuation: $
Scope of Work (please provide detailed information):
Will there be new rack storage? ❑ ..Yes ❑.. No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ .. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No
If "yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
\permits pltu\icc changes\permit application (7.2000)
Page 2
-€ 1glt'I'Ype:
'::Qty:::
! Unii pe:.
QtY;:::
;Uti[tType: :Qty:::
Boiler /Compressor:
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0-3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood
Water Heater
50+ HP /1,750,000 BTU
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator - Comm/Ind
Other Mechanical
Equipment
.�f1T �fIF �L fi
MECHANICAL CONTRACTOR INFORMATION
Company Name: F i v e c 4 o f m e Ck afl 1 C Ca-Q-
Mailing Address; LI a. 10 l�' s+i e..4 kW S(LLt L F A (Abu rt W A n t %39. o
City Stela Zip
Day Telephone: . 9 0 G - 1 1 ('' 8 Z-1 7
E -Mail Address: Fax Number: 2 5? ' 5 J - $.2 XI(
Contractor Registration Number: F. ve s rv1 #' 00 GC-3 Expiration Date: F' e (/v2.3 /2606
...An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance*
Contact Person: T6 k to a r
Valuation of Project (contractor's bid price): S
Scqpe of Work (please provide detailed infonn;n):
Residential: New ❑ Replacement ❑
Commercial: New .....0 Replacement tis,
Fuel Tvoe: Electric Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
P ER IT Pi A ZxON !TQTE,S �» A ppiiie ib u su p
Mailing Address;
teppNwtiotstpmait eppiiutlon (7.2001)
cath S \_ 1. \
5 •
Page 4
f 4).e1 J 14l7;1 -. l -e
�llli
Value of Caa*ruelian - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING ZUTIpjj GENT:
Signs Date:
..3 t [ A 7 G Day Print Name: � w ? Da Telephone:
S t ►; be 1 _
Lau 4 . 1 , t ,. L Yt cd0
city Mate
Zip
78
Parcel No.: 3523049107 Permit Number: M04 -198
Address: 17855 SOUTHCENTER PY TUKW Status: ISSUED
Suite No: Applied Date: 11/04/2004
Applicant: HOME FURNITURE Issue Date: 12/13/2004
Receipt No.: R04 -01665
Initials: SKS
User ID: 1165
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Payee: FIVE STAR MECHANICAL
TRANSACTION LIST:
Type Method Description Amount
ACCOUNT ITEM LIST:
Description
Payment Check 25444
MECHANICAL - NONRES
RECEIPT
562.80
Account Code Current Pmts.
000/322.100 562.80
Payment Amount: 562.80
Payment Date: 12/13/2004 02:53 PM
Balance: $0.00
Total: 562.80
7799 12/14 97:16 TOTAL 562, :tt)
Printed: 12 -13 -2004
Parcel No.: 3523049107 Permit Number: M04 -198
Address: 17855 SOUTHCENTER PY TUKW Status: PENDING
Suite No: Applied Date: 11/04/2004
Applicant: HOME FURNITURE Issue Date:
Receipt No.: R04 -01491
Initials: SKS
User ID: 1165
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Payee: FIVE STAR MECHANICAL
doc: Receipt
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 25368
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NONRES
Payment Amount: 133.20
Payment Date: 11/04/2004 01:51 PM
Balance: $562.80
133.20
Account Code. Current Pmts
000/345.830 133.20
Total: 133.20
6665 11/05 9716 TOTAL 133.20
Printed: 11 -04 -2004
,
tt rodect: 4 . CtAA 'n t
Type of Insp qri
A ddress . --
c� s.C` ��
bate Called:
Sp cial Instructions:
'
w eii-/-)
Date Wanted:
a.nt.
Requester:
Phone No: "`
Cori\ 7P (e- 9a7
mo /(qQ
INSPECTION NO. PER I
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes: •
INSPECTION RECORD
Retain a copy with permit
Corrections required prior to approval.
COMMENTS:
fi
$58.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
'Receipt No.:
'Date:
Proje •
Type of Ins
con:
Add ess
Lo .s .5c-itai
Date Called:
Spe Instructions:
Date Wanted:
pi,
.- 13-0 ---
Requester:
Phone No:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206)431 -3670
OMMENTS:
( Date:
Approved per applicable codes. Corrections required prior to approval.
El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
'Receipt No.:
!Date:
T "."
AC 6
AC 5
ation View
SEPARATE PERMIT
REQUIRED FOR: No to Scale
O Mechanical
Decbicai
Plumbing
▪ Gas Piping
City Of Tukwila
BUILDING DMSION
AC 4
S 1 - cAdfeSS
MILE COPY
Pans* Haa� - ►q6
� 12 13 - G�
ah of %drab
BUILDING DNISION
AC 3
ome Furniture Tukw ila
No changes shall be made do the sow
of wcrk without prior approval 0? 4
Tukwila Building Division.
NOTE: Revisions will require a new plan su bmq
and may include additional plan review fees,
1+7 g 55 £0vkL . bcwy
Pbn ra■lew approval is subject to errors and omiirlonR
Approval of construction documents does not aufholtle
the violation of any adopted code or ondlnance. Romilpt
d . . . • • and • • • . • Is admowNdsok
AC 2
AC 1
49"
Existing/Finished Grade
REVIEWED FOR
CODE COMPLIANCE
• NOV 1 7 2004
C ' . Of Tukwila
BUILDING DIVISION
ON
RECEIVED 1 A
(:ITY of Tt
NOV 0 4 2004
pERMIT CENTE■
ECEIVED
CITY 'FTIIK
29'1"
t'1O I?8
Drawing not
to scale.
Levitz Furniture Warehouse
100"
REVIEWED FOR
CODE COMPL
NOV 1 7 2004
City Of Tukwila
BUILDING DIV S ON
CITY OF TI A
NOV 0 4 2004
PERMIT CENTER
RECEIVED
CITY OF TI WWII A
OCT 2 9 2004
PERMIT CENTER
- 25'
0
U
T
1-1
C
E
N
E
R
P
A
R
K
A
Y
leflit.)L I III IL l Ulli W1) UI LIII I ;JUJ
¶',end To Pi intet
,.-it. To .. :2Jr :e! . n: .. l,li: ',.nes
ZUSGS Tukwila, Washington, United States 13 Jun 2002
i I I
171Serve •.Il11CI•t)s)l1.COI11'1)I IIIIII a asp \' 1 I \ 8&N I i I I 1)5 )2c./ I ti `) 'c) /2OO4
Terms of Use Privacy Statement
Change to L dne :cape
I'age 1 of 1
CEIVED
P TI IKWII A
EIVED
TI IKWII A
Z
Q
Z
ce W
6
J
O 0
• LU
J
W • 0
Q
CO
C5
W
Z =
I 0
Z 1—
W
U�
0 —
W W
H -
LL O
..
W
U=
0
Z
Table GD-3 — Genera( Data
Cooling Performance'
Gross Cooling Capacity
EER
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
Integrated Part Load Value
System Power (KW)
Heating Performance'
High Temp. Btuh Rating
System Power KW/COP
Low Temp. Btuh Rating
System Power KW/COP
HSPF (BtuM/atts -hr)
Compressor
No./Type
Outdoor Coil — Type
Tube Size (in.) OD
Face Area (sq ft)
Rows/FPI
Refrigerant Control
Indoor Coll — Type
Tube Size (in.)
Face Area (sq ft)
Rows/FPI
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan — Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
CFM
No. Motors/HP
Motor RPM
Belt Drive indoor Fan — Type
No. Used
Diameter x Width (in.)
Drive Type/No. Speeds
No. Motors
Motor HP (Standard/Oversized)
Motor RPM ( Standard/Oversized)
Motor Frame Size ( Standard/Oversized)
Fitters — Type
Furnished?
(No.) Size Recommended (in.)
Refrigerant Charge (Lbs of R - 22) 4
14
General
Data
71 Ton Convertible Units
WSC090A3, A4, AW
92,000
10,1
3,000/2,625
87.000
8.61
85,000 ,
7.78/ 3.2
51,000
6.79/2.2
— �,
1/Climatuf a Scroll
Lanced
.3125
17.00
3/17
Expansion Valve
Lanced
.3125
9.89
4116
Short Orifice
1A4 NPT
Propeller
1/26
DirectJl
1/.70
• 1,075
FC Centrifugal
1
12 x 12
BeltNariable Speed
1
2.00/3.00
1,750/1,750
56/56
Throwaway
Yes
(4)16x25x2
12.9
10 Ton Convertible Units
WSC120A3, A4. AW
119,000
10.1
4,000/3,2000
114,000
10.4
11.29
109,000
9.98/3.2
62,000 --
8.26/2.2
1/Climatuff Scroll
Outdoor Sound Rating (dB) 86 92
Lanced
.3125
19.83
3/17
Expansion Valve
Lanced
.3125
12.36
4/16
Short Orifice
1/i: NPT
Propeller
1/26
DirectJl
1/.75
1,075
FC Centrifugal
1
15x 15
BeltNariable Speed
1
3.00/ 5.00
3.450/3,450
56/56
Throwaway
Yes
(4)20x25x2
7.9 Circuit 11/7.9 Circuit 42
(71/2, 10 Ton)
REVIEWED FOR
CODE COMPLIANCE
AnDrinitmo
NOV 1 7 2004
City Of Tukwila
BUILDING DIVISION
r:ITY OF T IKW$l A
NOV 0 4 2004
PERMIT CENTER
RECEIVED
riry nr rr rwt,
OCT 2 9 2004
PERMIT CENTER
NOTES:
1. Cooling Performance and Heating Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb . Gross capacity does not include the effect of fan motor
heat. ARI capacity is net and Includes the effect of fan motor heat. Units are suitable for operation to *20% of nominal dm. Certified in accordance with the Air - Source Unitary
Heat Pump Equipment certification program, which is based on ARI Standard 210/240.
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown Is tested in accordance with ARI Standard 270. For more information refer to Table PD -25.
4. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
PKGRPR0003 -EN
I mo.
0 0.
y ID
cow
L ij
N O
W =:
— a
Z
UJ
0�.
U 0 ,
W ;
F-�
UN
D �
Z
. MIME'
Table GD-1 - General Data
General
Data
3 Ton Convertible Units 4 Ton Convertible Units
.- WSCO36A1 WSCO36A3.A4,AW WSC048A1 WSC048A3,A4,AW
Cooling Performance'
Gross Cooling Capacity 38,100 38,100 50,800 50,800
SEER' 9.80 10.20 10.50 10.70
Nominal CFM / ARI Rated CFM 1,200 / 1,200 1,200 / 1,200 1,600 / 1,600 1,600 / 1,600
ARI Net Cooling Capacity 36,600 36,000 48,500 48,500
Integrated Part Load Value - - - -
System Power (KW) 4.09 3.96 5.16 5.05
Heating Performance'
High Temp. Btuh Rating 35,000 35,000 47,000
System Power KW 3.46 3.35 4.68
Low Temp. Btuh Rating 18,600 18,600 28,800
System Power KW 2.78 2.65 4.14
HSPF (Blu/Watts -hr) 6.75 6.95 6.80
Compressor
No./Type 1 /Climatuff®
Outdoor Sound Rating (dB)
Belt Drive Indoor Fan - Type
No. Used
Diameter x Width (in.)
Drive Type/No. Speeds
No. Motors
Motor HP (Standard /Oversized)
Motor RPM (Standard /Oversized)
Motor Frame Size (Standard /Oversized)
12
FC Centrifugal
1
11 x 11
BeltNariable Speed
1
1.00/ -
- 1,750/ -
56/ -
REVIEWED FOR
CODE COMPLIANCE
j PPRO)'9D
NOV 1 7 2004
(3, 4 Ton)
BUILDING DIVISION
1 /Climatuff 1(Climatutf Scroll a 1 /Climatuff Scroll
84 84 83 83
Outdoor Coll - Type Lanced Lanced Lanced Lanced
Tube Size (in.) OD .3125 .3125 .3125 .3125
Face Area (sq ft) 9.59 9.59 9.59 9.59
Rows/FPI 2/17 2/17 3/17 3/17
Refrigerant Control Expansion Valve Expansion Valve Expansion Valve Expansion Valve
Indoor Coil - Type Lanced Lanced Lanced Lanced
Tube Size (in.) .3125 .3125 .3125 .3125
Face Area (sq ft) 6.17 6.17 6.68 6.68
Rows /FPI 3/16 3/16 3/16 3/16
Refrigerant Control Short Orifice Short Orifice Short Orifice Short Orifice
Drain Connection No./Size (in.) 1/ NPT 1PA NPT 1/'/+ NPT 1/',4 NPT
Outdoor Fan - Type Propeller Propeller Propeller Propeller r..ITY OF TI a
No. Used /Diameter (in.) 1/22 1/22 1/22 1/22
Drive Type /No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 O CT 9 200
CFM 2,950 2,950 3,200 3,200 J
No. Motors /HP 1/.25 1/.25 1/.40 1/.40
Motor RPM 1,075 1,075 1,075 1,075 PERMiT CENTER
Direct Drive Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used 1 1 1 1
Diameter x Width (in.) 10 x 10 10 x 10 11 x 11 11 x 11
Drive Type /No. Speeds Direct/2 Direct/2 Direct/2 Direct/2
No. Motors 1 1 1 1
Motor HP (Standard /Oversized) .33/.50 .331,50 .60/.80 .60/.80
Motor RPM (Low /High Speed) 950/1.060 950/1,060 930/1,000 930/1.000
Oversized Motor RPM (Low /High Speed) 1,100/1,145 1,100/1,145 1,000/1,100 1,000/1,100
Motor Frame Size (Standard /Oversized) 48/48 48/48 48/48 48/48
- FC Centrifugal
1
- 11 x 11
BeltNariable Speed
1
-
1.001-
_ 1,750/ -
- 56/ -
nil/ OF 1 1 I KW II A
47,000
28; 00 NO V 0 4 2004
4.02
6 PERMIT CENTER
Fitters - Type Throwaway Throwaway Throwaway Throwaway
Furnished? Yes Yes Yes Yes
(No.) Size Recommended (in.) (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1
Refrigerant Charge (Lbs of R -22) 7.5 7.5 10.2 10.2
NOTES:
1. Cooling Performance and Heating Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb . Gross capacity does not include the effect of fen motor
heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to *20% of nominal cfm. Certified in accordance with the Air•Source Unitary
Heat Pump Equipment certification program, which Is based on ARI Standard 210/240.
2. SEER is rated at ARI conditions and In accordance with DOE teat procedures.
3. Outdoor Sound Rating shown is tested In accordance with ARI Standard 270. For more information refer to Table PD-25.
4. Refrigerant charge Is an approximate value. For a more precise value, see unit nameplate and service instructions.
PKGRPR0003 -EN
1
50
Table W 1 -- Maximum Unit Weights, ComerWeights (Lbs)And Center Of Gravity Dimensions (In.)
Tons
Unit
t
CENTER OF
GRAVITY
WIDTH
D
CENTER OF GRAVITY
Weights
Maximum Weights (Lbs)
• CENTER OF GRAVITY
4 LENGTH —►
A
Accessory
Economizer
Corner Weights (Lbs)' Center of Gravity (In.)
Model No. Shipping Net A B C D Length Width
WSCO36A '' 496 442 , r 138 110 88 105 31 19
4 WSC048A 528 474 151 114 95 114 31 19
5 WSC060A 546 492 160 118 97 117 31 19
WSC072A 859 772 38 22 259 196 136 181
WSC090A rf 881 794 38 22 272 200 137 185
WSC120A' 1028 941: 38 21 320 243 162 215
1. Caner weights are given tor information only.
•
•
1
R EVI C ONIPLI Q N
CODE
N0 V 1 7 2004
0� 'Vul {wil
O N
r1 I Y OFTi RtAn1
NO V 0 4 2004
PERMIT CENTER
(:ITV nF T1I WWII A
OCT 2 9 2004
PERMIT CENTER
Table W2 — Factory - installed Options Net Weights (Lbs)r'
Net Weight
3 -5Tons 6.10Tons
26 36
Barometric Relief 7 10
Powered Exhaust — 80
Motorized Outside Air Damper 20 30
Manual Outside Air Damper 16 26
Roof Curb 70 115
Oversized Motor 5 8
Belt Drive Motor 31 —
Smoke Detector, Return 7 7
Smoke Detector, Supply 5 5
Coil Guards 12 20
Hinged Doors 10 12
Powered Convenience Outlet 38 38
Through the Base Electrical 8 13
Electric Heaters 15 30
Unit Mounted Circuit Breaker 5 5
Unit Mounted Disconnect 5 5
Novar Control 8 8
NOTES:
1.Weights for options not listed are >5 lbs.
2.Net weight should be added to unit weight when ordering
factory- installed accessories.
PKGP- PRC003 -EN
•
OCT. 22. 2004 12:39PM AI REFCO
Specifications
Ouarrtt'ty ... Type
Ott (oz)
Refrigerant R -22 Charge (lb)
Cutout (psig)
Reset (• Sig)
Type
Quantity. Size On
Roof Curb 14 inches
24 inches
Manual Outdoor Air Damper
Two - Position Damper
Modulating Economizer
Electric Heat Packages
00 - Belt Drive DD. Direct Drive 4FaCbrysetting
*Copper tubes, aluminum fins " Propefler, dIreci drive
tContritugel Ian
4
. • .... , ...,, -a. .4. j , °'. (j u
r
iT
rj'I Tt x T�': y,. •r . tr., n .(• g.v. ( ! . ..•. ,.�. q.'r. q ••' ti • Y ..�.r t - 7 •? 4 7. 'r �
I i•: I w •.•.�iY.�. c:.7.'liti ' .., At' r l` . 1 : dY. 7 r . �Y�� fi 5:.�. .;:; ! I.., � T r -
,d : � r ,. r t :. " C1r •. jrr, <.. � + .�i ,s7 l� ' : k
(.. •r- r 7 3Y' J .. 7 � ,.�. i .. �-'r f , _ r �,. �,,.. 3 "+, "� s r [. r-. �• t , „, 4, s s .,
1 L . . 5 1 e b • r f :a 4 J 1 ., 1 1. <' + f l ry .'.. (`'t,� "77r r! , ,,M g t t . d'
� • t` 4i,L a t..:t . { .• {' +1" I .... :t:..�' y.: .,
:i:7s .t.2:,�ih •t:l� +.t ?. • t, �. t�eti # i' �t f: .�rr�[.! .F�n�>!.`. :sl, !tt SA'1G3.:16i''.".4n .. h. .1 •wi f:.'.:..r...L +�l•.
460
485
130
80
535
2
13.9
5.33
470
495
130
80
545
1 .. Copeland - CRJ
51
1 . Copeland - CRM
66
!Ar1� .�. .... :•ot_..i it :24 4 ..3:c.YtL"::^i..
2
139
5 33
miter 1 - � i•a;X. ?' ( { r '�, GS x '� r ;. Zi r • -> .ij:• •gy�! , Y ' 3 y � •..E Ly',�.
�,i•ib'4 -r.t•i 3 � ii n.. 1' ^:1� t:: n!Itsn.r` t! t..L.'s J, 1.'. r.r �r1.� -.( ". .. .JL7.�.iG.'>t' :. .. •:vn4...
1 10 x 10
D.D.
1200
1050$ ��..
RE
e
114
COD
3/4 (1 2
1/3(100 - ---
r
1,,.10x10
D.D
1500
IEWE I9NNCE
COM
ttno ( V47)
1140
0V 7 2004
qty Of Wil
DIN c/ [AVISx
1. •10x10
0.0
2000
1140
1100*
1050
1050
890
1140
RECEIVED
r IT\•TiF TI IKsNII P
NOV 4 2004
PERMIT CENTER
1 (1.25)
3/4 (1 25)
2
170
6.3
�
r "7 j `: }S+'•,,.'., ? :'t'h 7�'?.N'It . • . . •
t iftita•!.
;: r��+' rt,..J- 'i1 , L ` � ; vr i'1 ' tQ`.�,c' I jp' I l mot°• "• '!'.� �• *'T'.�`
, SAtia.'d',.iw d.��� .L' ' /ii ta,.:u' ryC.... .,
3100
1..22
1/2 1075
2
139
9.73
3100
1 . 22
1/2 1075
490
505
130
80
555
1 -. Copeland • CRN
66
73
3
139
5 33
r. }�.�C: .r "• j %lr ''r r '�. .. l' r 'l T t ,. ..:: it
2
17
9.73
3600
1 .22
1/2 .1075
!
f•-uyv ,r. � ;r'• � r'r '?.rp;gr �-:,y , y r ,r 1 -p. -
.] jjy'
1 rF l . P:74 r
M'J� .V r I• . J.Y.. ' �) .�. 'l lr. �1t�'.l. l:. I` .
j3,w ,:tl' 1- 7 - ?y' .i )1, 1'E
• '� � + it�tt•rd 1 :J �) t,•Ca:, W
t' �aiY'�.rFAA l
'4�eµi�.�r
Unit (16)
With Economizer
Roof Curb — 24 inches
14 inches
Unit (lb)
Rowe
Fns /inch
Total Face Area (sq M
Rows
Fins /inch
Total Face Area (sq
fd
Nominal am Quantity Diameter (n)
Motor Hp Rpm
520
545
130
80
.�:r;r.' %' ?.•�►'{"::hF, �:t f ; PITc � . „� . . a .. ...-'i- ,i,J ... s >y-' � '
'G', Ss2 .., .l 5::.,
.�.M•��r,.:.vr'2 '74:r 7�.! '7ti 7r.,.. :.� .f•,.:3.7v^:•E.:Y•t:l�. ��`.:! � �ilos , 1 i
1 ti•" '�;� T.tj1}•.
605
fi :i?:Z I74 t•✓ /jEj• tXl; . , .L,�•,�e , s -�, - s ,rt, w,, , ��y.r. y�,. . , .1* jr 1, • !i� ,i � , �p " t' ' R',��" 1 + 1 ! ` 7 ri^' rr 1'� t s�� N !�� ( .it !I Tx!• ;•.� ,:f.L•,-�q�!y 1
.• „t '.(.y i✓<::.1.:hi fl :. ,f,� Z7 �l.�Y.�jlYs.' .R' ?: ..•1= �7: -M1M =•L. [L... r!(•,t:17+ ri VA'? .1!i�.
.'!l`t�l. ..J..1;.it- ;7:tls'.`if,.�::.. �. "X•Y �i i,ir "1: .T
1...P -77
74
9.3
4
139
6.3
3
139
10.8
4000
1 22
1/2 1075
Quantity .. Size (inches)
Type
Nominal elm
Rpm Range
Standard High
Med
Low
Optional High ; 'r
Med
Low r
Maximum Allowable Rpm r
Motor Pulley Pitch Diameter (in)
Fan Pulley Pilch Diameter (in)
Bell. Quantity . Type ... Size — —
Speed Change per Full Turn of
Movable Pulley Flange (Rpm)
Movable Pulley Maximum Full
Turns from Closed Position t
Factory Setting Full Turns Open
Factory Speed Setting (Rpm)
Motor Hp (Service Factor) Std BUI
Opt —
;,.,;c�ts I i • • ;%; ' .. ta( . ' ” 7 l:r 1 Fq� 4 tKa{°jp s' . t �.r T F ie Fa f . F'� a;7
a :4:,arr ...,�` ?, rsi3kl tl• � •rt. k �• i �7.a'... ':J: L .:a�tYi' r i(�(•... l Xilk a ,.1.:ut . ,. � � I .:
27 t4
87 f7
1
19x32x1/2
Disposable
1 . 16x25x land 1 20x25 x1
310981 -201
310961 -202
309423 -101
309422.101
309421 -101
NO. 553 P. 8
1•.,11x10
B.D
2400
796 -1128
1260
2 4-3,4
52
1 . A. 34
66
5
3
1130
1 (1,50)
,,7" f t'. ?•: ! .,R '. = •1 r . j . .. � a . 7.7e - • .. , s 't`�..Cr 1' .T',p 'fie. 1 , {• „C ;•TPrj• +Jr' �: . i j 5f' ; r i
Tt •t e r °�� . ) 1, yq,� �''s'
.��1�.•.:,;�6F 1t �.'u.:t1'..:.�.r+A ts'�'a�•ti �� 1.•1fw� r y 7`(�: �.i:s{ • �, k s 1�4 7 r 4 .� t ' • .i Ai .t► : s , M i. it .�r�n<.,._ �. �� .ii':'''. • 1..,•iY. il'... aa . Sr �.
(Accessory/Option)
Quantity
Size (Inches)
j,M,Zarri3•�g !'' � [�"�i1. ,.:;T2i:I I.;'w }r k�,•,�+,t� t fi r1� l�lj �'} 2-�i, t`�" y�• 4' ^(? ^.. £ sj� .,..✓ ,,.�y, :`�r,� :,ly+A� 1; ;'�'��'
r i 7. Ce t L Y rht � t5 � u'O1 • Y. .w II}�1$ iii 1'•t 1u� !• �'>,.�_ 3Y't�':li i� iFd" de{ It'¢ I' (x +1 •'tar i_
ii Na►tE- q.1':. 3 •> f ' 4 .. . ,.. 1; . x ,;. E'.....rI., 13' p : �• �t:f�,.
RECEIVED
P44 Ti1KM
ttbisposable one inch tillers included with units; field- supplied 2lnch fillers that MIT CENTER
not exceed pressure drop of 1 0 in wg may be used
SIZE
Front
Rear 1- -W-RI: tStde - "
Left Side
Top
- 090,120, 8,150
2 it
2 , i Al I.. G
5 a
Keep Clear -
190
2 _
2 L p . - ri1 T a I('F
6 t _
Keep Clear
Size
Size
Operating
Wt
A (Min)
8 (MM)
C
D
E
090,
120, &
150
56
32
80.7/15
56 -5/8
133/8
1785
180
327
68
38
98 -3/8
66.5/8
16 -3/8
Size
Approximate
Shl L." • WI
Operating
Wt
Corner Weights
A
B
C
D
090
1640
1210
299
271
300
340
0205.1x:
160
1785
1 It .. :',
327
297
342
389
2000
1570
370
338
402
460
2264
1720
447
433
415
425
'OCT. 22. 2004 12:37PM
SIZE
90. 120, & 150
180
latm war
90
107
65
6 -5/8
85-
80 -7/16
98 -3/8
G
21 -7/8
23
aim
3/4
1 -1/4
1 -1 /2
13-1/2
14
35-13/18
45 -13/16
M
3
3 -11/16
N
11 -1/16
ECISEEIEI
P
48-1/16
60-1/16
t7
ill
40
10
9
IN OUT
Left —Side View
Sizes
090 & 120
e
N:1•
• UT
(TOP
A
FRONT
AIREFCO
REAR C
UNIT DIMENSIONS IN INCHES
Top View of Unit Base
3
A73064
A
CURB INSIDE
Front View
OUT
OIL
ROIL '
DIMENSIONAL DRAWING
NOV 1 7 2004
city Of - (u
ONLY
4 MAX
STU•50
• - - -u t■, 1. d1' IV' at. 114.111It..4A .
NOTE 1
NOTE2
Mr
OPERAT NG AND SERVICE CLEARANCES
L
M
RECEIVED
CITY OF TI WW1 A
NOV 0 4 2004
PERMIT CENTER
N0.553 P. 3
POUR N0.2 AWG TYPE - THW WIRES ARE
ES
LARGT SIZE WIRES THAT 1d1wNCHi.MIT C . NTEi1
Timm COUPLER WILL ACCOMMODATE
nun N0.1 AWG TYPE ■THW WIRES ARE
LARGEST SIZE WIRES THAT 1 - 1/2 PIPE
THREAD COUPLER WILL ACCOMMODATE
CURB M151DE
OUT — D
Right —Side View
All
e. Sizes
WEIGHT DISTRIBUTION ON ROOF (LB ) P URB R r UGH•IN DIMENSIONS
FRONT
r•IT Y( Ti E )F I wii A
OCT 2 ; 2004
A77130
..4.w...... «.w_v,�... • ..:. •' - .. - ti _... •
A73344
SFCA
'�SACA
75
A".,...
1814
21%
8 . .,f -
27
33
C
�4.1
21%
0
27
33
Net Wt.
78
166
OPTIONAL
SUPPLY AIR
FIGURE 18 -2
2 x 4 NAILING STRIP I
CONCENTRIC
DIFFUSER
73 I
Five Star Mechanical
HVAC Service & Construction
4210 B Street NW, Suite, F
Auburn, WA 98001
68%
18
44 N.P.T.
DRAIN CONN.
\ 14 1111N
tlol
• 04 1
FICUR�, EWED FOR
ODE COMPLIANCE
i 1 7 2004
L �
RECEIVED
CITY nF TI n WII A
NOV 0 4 2 0 04
pERMIT CENTER
City Of Tukwila
BUILDING DIVISION
FIGURE 18 -1 Page 18
SFCA, SACA 50 -75 Unit Dimensions
SFCA
SACA 50 75
L 67% 78%
A 41% 52%
8 35% 461
Net SAGA 1020 1235
Wt. SFCA 1090 ^� a5C1"'.
Filter Size 4- 16x20x1 4- 16x25x1
FIGURE 18 -2 Page 18 — Roof Curb
ALL DIMENSIONS APPROXIMATE
CERTIFIED PRINTS ON REQUEST
SFCA
SACA
A
8
C
Net Wt.
50
29%
33%
35%
94
75
401
44'A
46%
106
rITY nr TI a
OCT 2 9 2004
PERMIT CENTER
FIGURE 18-3 Page 18 — Concentric Ouct
1
05 -03 -2005
JOHN WARE
4210 B ST NW, SUITE F
AUBURN, WA 98001
. Permit No. M04 -198
17855 SOUTHCENTER PY TUKW
Dear Permit Holder:
City of Tukwila
Department of Community Development Steve Lancaster, Director
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this cude shall•expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Permit Center at 206 -431 -3670 to arrange for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 daps.
Extension requests must be in rvritinx and provide satisfactory reasons why circumstances beyond the applicants control have
prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 06/11/2005, your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Stefania Spencer,
Permit Technician
xc: Permit File No. M04 -198
Bob Benedicto, Building Official
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 =3670 • Fax: 206- 431 - 3665'
Steven M. Mullet, Mayor
Ei
ACTIVITY NUMBER: M04 -198
PROJECT NAME: HOME FURNITURE
SITE ADDRESS: 17855 SOUTHCENTER PY
DATE: 11 -04 -04
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision #afteilbefore permit is issued
DEP RTMENTS: ��(0�
dy' A1iu(� MI
s i r' Division
Public Works ❑
DETERMIN ON OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -09-04
Complete Incomplete ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS R TING:
Please Route Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 12 -07 -04
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2.28.02
PERMIT COORD COP
PLAN REVIEW /ROUTING SLIP
6(0 kik&
Fire Prevention ij
Structural ❑
PERMIT COORD COPY
Planning Division
Permit Coordinator
Not Applicable ❑
DATE:
"1N3WIla0a H1 :O AiiivnO 3H1 Ol 3na S11133110N SIHl
NvH aV312 9931 SI 3WVZIA SIHI NI1N3WI1000 3H1 Al . :931.1ON`
- .
S i► �tL
Issued by 9.' ARTMENT OF LABOR AND INDUSTRIES
License Information
License
FIVESM*010JT
Licensee Name
FIVE STAR MECHANICAL
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601937083 Verify Contractor Premium
Status
Ind. Ins. Account
Id
Business Type
CORPORATION
Address 1
4210 B ST NW STE F
Address 2
City
AUBURN
County
KING
State
WA
Zip
980011717
Phone
2538528284
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
4/30/1999
Expiration Date
4/30/2006
Suspend Date
Separation Date
Parent Company
Previous License
COMFOP*064D2
Next License
Associated License
Look Up a Contractor, Electrician or Plumber License Detail
Search
I General/Specialty Contractor
A business registered as a construction contractor with Lai to perform construction work within the scope
of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment
of account and carry general liability insurance.
Business Owner Information
1
Name
Role I
Effective Date
Topic Index 1 Contact Info 1
Find a Law or Rule Get a Form or Publication
https://fortress.wa.gov/lni/bbip/detail.aspx?License=FIVESM*010JT
Page 1 of 2
Horne Safety Claims Et Insurance Workplace Rights Trades Et Licensing
. .
Look Up a Contractor, Electrician or Plumber
12/13/2004
ACOMMINEEMen