Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M04-215 - THE 13TH REGIONAL CORPORATION
rl • THE 13"' REGIONAL CORD BLDG 40 1156 INDUSTRY DR M04 -215 Parcel No.: Address: Suite No: Value of Mechanical: $4,800.00 Type of Fire Protection: City 6 Tukwila Contact Person: Name: PETER CREELEY Address: PO BOX 33370, SEATTLE WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: ci.tukwila.wa.us 2523049071 1156 INDUSTRY DR TUKW Tenant: Name: THE 13TH REGIONAL CORPORATION Address: 1156 INDUSTRY DR, TUKWILA WA Owner: Name: CALWEST INDUSTRIAL PROP Address: C/O DELOITTE & TOUCHE LLP, 2235 FARADAY AVE #0 Contractor: Name: PRO -STAFF MECHANICAL INC Address: PO BOX 33370, SEATTLE, WA Contractor License No: PROSTMI006C8 DESCRIPTION OF WORK: REPLACE ONE EXISITNG 5 -TON A/C UNIT WITH A NEW 5 -TON A/C UNIT. Furnace: <100K BTU 1 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat /Refrig /Cooling System.... 1 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: EQUIPMENT TYPE AND QUANTITY Phone: Phone: 206 - 361 -0071 Phone: 206 - 361 -0071 Expiration Date:06 /30/2006 Steven M Mullet, Mayor Steve Lancaster, Director M04 -215 01/14/2005 07/13/2005 Fees Collected: $241.95 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper Diffuser Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 0 doc: IMC- Permit * *continued on next page ** M04 -215 Printed: 01 -14 -2005 Permit Center Authorized Signature: Signature: Print Name: TD KZ L-5190 LI doc: IMC- Permit City c,? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.tiva.us 0.106e; • Date: Date: Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: MO4 -215 Issue Date: 01/14/2005 Permit Expires On: 07/13/2005 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. `7`(0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M04 -215 Printed: 01 -14 -2005 UO` catLi N o W O; g -J Z ��. Z 1--; 11J La U ` '0 S D 1-; w w ti N' 'O City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2523049071 Permit Number: M04 -215 Address: 1156 INDUSTRY DR TUKW Status: ISSUED Suite No: Applied Date: 12/03/2004 Tenant: THE 13TH REGIONAL CORPORATION Issue Date: 01/14/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page ** M04 -215 Printed: 01 -14 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: � ' Date: 1 / /1-t ` r RC. C. nb Print Name: / doc: Conditions M04 -215 Printed: 01 -14 -2005 Name: PEI GQc LL r -Jl Mailing Address: R D. Sux "a337D Company Name: Mailing Address: Contact Person: E -Mail Address: iENGINEER.OF ~. +` .. 1.�..iS •;i�r`� >r'�t .:;tti s�..}t:. -� 4l�ttr!�ty:�c 'Company Name: Mailing Addre Conta erson: ail Address: CITY OF TUKWII,.. Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 CHITECT�OF ;RECORD lnsn �:h.o .i'3;a: i g� i( ".!'+�•zSi�' =�_: �'„`.'•- -1 i1 "" �:.:s:'. -� %''',.� �,}+�,::.vxt::Sj2E � w:: ., •:;f .'a:•11�. Y.Li)�. 'Yt;r' ?:; .µ'l! �.'r _.. .., ::�E.�a?r.'.�ii'T.':�C:'!' ?. �:i• ".G'�if.:'r.� Vpplicatiotu\pennit application (3.2003) 3/2003 E -Mail Address: PE'>t0/- eA4AN t- " cwt^++ 044:s Mped: Ali plans must be wet�st Page 1 b i y Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** "�2 ;. + •-ps::n,. �,. .. -- '+ .. A .'. s ... s a 7 ^�`• G.: - y�:r.• - ?� _ - - .!'', 6f .t-' - "ti,a 15 ge I � ; :i t t i 'a •- .u.n Fy•v .`• •yy .• _ k7 . .; Sur; o� �.ioN,: � h.'s+.l � ' `!• r. '1 �.•�r,� � RCU 'a,,•, t� x 'r'.- - ,. 'it*+. .-4 x .'`' •':;,,.. -#^ r.� -' +l:tC: T= v: ° • - 5- �n•...$: K "A.ir..; s r ,j1:1.. `x .:M - ... ...),A '. L?a�.'} 1 . ee,.+`��`,,. , , ' c.: — ' ' a 4rq :-'1 , - ral `�' r; ?: ` .: =i. Yi:L.. Li...m f. ^,:a+ .!1c• - .- i Yi::37{ • bo. >n:y.•., ta.. ., -s :s. 9G.^r ,7.0..E . -. ... �4`'yii•t..33G. A...4,- r - at�.'�'aziF.- -•?-..,x' :.7., e :.:1!,ti';s..i:` sy ing Co Assessor's Tax No.: 'Is - 2_ 3 a4 ci v 7 / Site Address: '1 1 5 6 1 H PL TlZ,► a IZ I V1 61 9h 4 9 6) puite Number: )) S 4, Floor: 1 Tenant Name: 'The 1 fZGLi/ca' -)A-c. GorziPoR...4-1 -4 New Tenant: 0 .... Yes yt .No Property Owners Name: KR t r Mailing Address: e 5 13 L-✓t' - 1 v>z wi�/4 City Company Mailing Address. Contact Person: E -Mail Address: Contractor Registration Number: * *An original or notarized copy of Curren ashington State Contractor License mu '!r Day Telephone: 2-Ola -3l0 /— OD 7/ City State Zip Fax Number: 2-0 !a •- 36/— c4 2.4- City Day Telephone: Fax Number: Expiratio t . ate: e presented at the time of permit issuance ** itccfofRecor ngineeroRecor w state City ay Telephone: Fax ` • t ber: Sta State Zip 9 911) 33 Zip Zip :•rte;- • v >..:,�_ City State Zip Day Telephone: Fax Number: t. Unit Type:.` . -Qty : Unit.Type: , . ; : _ : Qty ` Unit T : ::Qt y .::;:::: Boiler/C Qty, . Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace> 100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM ' Incinerator — Comm/Ind '..MEOIAMCAI EER.MIT INFORMATION. °206=4313670 MECHANICAL CONTRACTOR INFORMATION Company Name: PR- J- /}Tl= yvi e4,4 )c A-t— Mailing Address: 7- 0_ 3 vx - $3370' City Contact Person: PE i742 1_Le. y E -Mail Address: j r ER- Q ?Ro- yi itGF 1M Er - 4/. AL Fax Number: 2,96- 32.) - c:47-4 Contractor Registration Number: 1 T )M 772N L, Expiration Date: /�3/ /0$ * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ T 9 00 _. . Scope of Work (please provide detailed information): 'RE-Pi-AC/T:7 T: 1=w.5711�t, 1 014 A G (/H )-r \d m.) A- 14E4/ c- I DN Vhf - F R - L.)w =' Use: Residential: New ....p Replacement .... 0 Commercial: New ....0 Replacement ... Fuel Type: Electric VL Gas....D Other: Indicate type of mechanical work being installed and the quantity below: .PERMIT: APPLICATION'=NOT :.!� S%J. - , �t:. ' q�±,iL_'"''+- ,,, {�'�i.'J!�� Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN $R' AllTHO: Z !, GENT: Signature: Print Name: 1 Mailing Address: ' V Date Application Accepted: 4-3 \applications\permit application (3.2003) tntm E. 33 Date Application Expires: Pave 4 Day Telephone: "p1., - 3G1- D0,1 Day Telephone: 7-06 City Vt/A 963/33 State Date: ) 3 / 0.1- i - W4 c l X 133 State Staff 1 i'als: Zip Zip .t. y..� • ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payee: PRO -STAFF MECHANICAL INC '.MECHANICAL - NONRES RECEIPT Parcel No.: 2523049071 Permit Number: M04-215 Address: 1156 INDUSTRY DR TUKW Status: APPROVED Suite No: Applied Date: 12/03/2004 Applicant: THE 13TH REGIONAL CORPORATION Issue Date: Receipt No.: R05 -00059 Payment Amount: 175.56 Initials: SKS Payment Date: 01/14/2005 01:53 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 8589 175.56 Account Code Current Pmts 000/322.100 175.56 Total: 175.56 39!w.3 O1 /19 971.0 TOTAL. AL. 351 i Printed: 01 -14 -2005 Parcel No.: 2523049071 Permit Number: M04 -215 e .0 Address: 1156 INDUSTRY DR TUKW Status: PENDING co o Suite No: Applied Date: 12/03/2004 . w,. Applicant: THE 13TH REGIONAL CORPORATION Issue Date: ii -. �, W O i . 5 Receipt No.: R04 -01625 Payment Amount: 36.39 ? u. a Initials: BLH Payment Date: 12/03/2004 01:21 PM P w User ID: ADMIN Balance: $175.56 z f-: 111 U 0 O Ni 0 1-' wW Z Type Method Description Amount Li. 0 36.39 I11 � , V z Payee: TRANSACTION LIST: Payment Check 8493 ACCOUNT ITEM LIST: Description City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PRO- STAFF MECHANICAL INC PLAN CHECK - NONRES. dm: Receipt RECEIPT Account Code Current Pmts 000/345.830 36.39 Total: 36.39 2103 '.716 TOTAL 72.7E1 Printed: 12 -03 -2004 P of /7 Type of Insp on: Adilresx, Date Called: Special Instructio s: •" _ /� fpm ate Wanted: , rim Requester: .([ 0. x4111 Phone Noo: / 4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PE proved per applicable codes. Corrections required prior to approval. (206)431 -3670 COMMENTS: k 1;71 O I/0 le clot: Date 8.00 REINSPECTION EE REQUIRED. Prio ' to inspection, fee must be aid at 6300 Southcent r Blvd., Suite 100. all to sechedule reinspection. Opt No.: !Date: Pro ecti %./ I a ,/, Type of spection: , • A!;4 ` 0 As dress' Date ailed: Special Instructions: Date Wanted I ( a.m. Requeste Phone ,!�N� 4/7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: $5 p Approved per applicable codes. Corrections required prior to approval. Date: .00 REINSPECTION F E REQUIRED. Priorfto inspection, fee must be d at 6300 Southcent - Blvd., Suite 100. ll to sechedule reinspection. (Receipt No.: 'Date: 5 13LOC-, "D D Ac-3 40I-1-E HO (6-__Tom) Packaged Gas /Electric Rooftop Units C ODE COMPLIANCE R rt*.-,14 ) PrecedentTM 3- 10Tons -60Hz FILE COPY C RECENED DEC OF ni tovI,q ©3 2004 PERMIT CENTER M04 -27 5 DEC 2 3 2004 Or' l`u :Zi WING DIVISION RT- PRC006 -EN z } Z � J t=.) 00 0 N J F. U) w ga = a u �. F- O z►- w w. U O N 0 I- • 0 .z w • = O ~ z Table GD-2 — General Data Cooling Patfohnancel Gross Cooling Capacity SEER/EER Nominal CFM / ARI Rated CFM ARI Net Cooling Capacity Integrated Part Load Value' System Power (KW) Heating Performance Heating Modals Heating Input (Btu) Heating Output (Btu) AFUE %° Steady State Efficiency ( %) No. Burners No. Stages Gas Supply Line Pressure Natural (minimum/maximum) LP (minimum/maximum) Gas Connection Pipe Size (in.) 1/2 Compressor No. Type Outdoor Sound Rating (dB)° Outdoor Coil - Type Tube Size (in.) OD Face Area (sq ft) Rows/FPI Indoor Coit - Type Tube Size (in.) Face Area (sq ft) Rows/FPI Refrigerant Control Drain Connection No./Size (in.) Outdoor Fan -Type No. Used/Diameter (In.) Drive Speeds CFM No. Motors/HP Motor RPM Direct Drive Indoor Fan - Type No. Used/Diameter (in.) Drivellpe/No. Speeds No. Motors Motor HP (Standard/Oversized) Motor RPM (Standard/Oversized) Motor Frame Size (Standard/Oversized) Low 60,000 47,000 81 81 2 1 YS 060A1 100 ,90/- 2,1 00/2,000 60,000 6.86 dium ,000 000 1 6 4.5 14.0 10. r 14.0 2 1 /Clime uff Scroll 4 La ced 0.125 81 17 La ced 0.3 25 6 3/1 Short 0 8ce 1/34 N Propel =r 1/22 Direc 1 3,47 1/0. 107 FC Cent ifugal 1/11 11 Dirac 1 0.90/1.0 985/1,080 48/48 General Data High 130,000 103,000 80 80 3 1 1/2 6Ton Convertible YSC060A3, A4, AW, AK , 63,100 10.20/- 2,000/2,000 60,000 6.78 LAN MIL" 60,( 00 80,000 48,( 00 64,000 8'' 81 8 81 2 2 1 1 Hi 130 104 1 /Climatuff Scroll 84 Lanced 0.3125 8.81 2/17 Lanced 0.3125 5.00 3/16 Short Orifice 1/34 NPT Propeller 1/22 Direct/1 3,470 1/0.33's 1,075 FC Centrifugal 1/11 x 11 Direct/2 1 0.90/1.00 985/1,080° 48/48 4.5/14.0 10.0/14.0 1/2 1/2 1/2 h 00 00 • TRAM' (3 - 6 Tons) Standard Efficiency' Lovy 80,000 64,800 81 81 2 1 6Ton C.rivertible YSC072A , A4, AW, AK 1 • imatuff Scroll 88 Lanced 0.3125 13.88 17 L: ced 0. 125 9.:9 6 Short Orifice 1P NPT Pr' peller /26 irect/1 6,100 /0.70 1,075 N/A /A, /A A 72,000 — /10.2': 2 00/2,100 9,000 77 Med um" 120 r00 97,'00 1 1 , 3 High 150,000 121,600 81 81 3 2 4.5/14.0 10.0/14.0 1/2 1/2 3/4 A NA N/A RTPRC006•EN 17 Notes: 1. HACR breaker per NEC, RT-PRC006 -EN • TRAM° Electrical Data (Standard Efficiency) Table ED-1 - Unit Wiling - Standard Efficiency In Standard Indoor Fan Motor ' Oversize Indoor Fan Motor Optional Bali Drive Indoor Fan Motor Unit Minimum Maximum Fuse Minimum Maximum Fuse Minimum Maximum Fuse Unit Operating Circuit Size or Maximum Circuit Size or Maximum Circuit Size or Maximum Tons Model No. Voltage Range Ampacity Circuit Breaker' Ampacity Circuit Breaker' Ampacity Circuit Breaker' YSCO38A1 187 -253 25.3 40 27.7 40 - - 3 YSCO36A3 187 -263 17.9 25 20.3 30 20.6 30 YSCO38A4 414 -506 9.2 15 10.4 15 10.6 15 YSCO38AW 517.833 , • 7.7 15 8.3 15 8.3 15 YSC048A1 187-253 34.0 50 36.1 60 - - YSC048A3 187 -253 23.9 35 28.0 40 25.3 35 4 YSC048A4 414-506 12.8 20 14.4 20 13.6 20 YSCO48AW 517-633 9.8 15 10.8 15 10.0 15 YSC060A1 187 -263 x�,,47 60 49.0 60 - - `4YSC060A3 187 -253 (r31.Ey 60 33.6 60 30.3 45 5 YSC060A4 414-506 0 18.3 25 15.6 26 ' YSCO60AW 517633 12.2 16 12.8 20 11.8 15 YSC060AK 342 -418 19.8 30 - - - - YSC072A3 187 -253 32.7 50 34.0 50 - - B YSC072A4 • 414-506 17.6 25 18.2 25 - - YSC072AW 517-633 12.8 20 13.6 20 - - YSC072AK 342-418 23.2 35 - - - - YSC090A3 187 -253 42.7 60 45.8 60 - - YSC090A4 414 -506 22.6 35 24.1 35 - - YSCO9OAW 517-633 17.6 25 18.8 25 - - 7' /x YSC090AK 342-418 28.9 40 29.9 45 - - YSC092A3 187 -253 38.9 50 42.0 60 - - YSC092A4 414.506 20.5 25 22.0 25 - - YSC092AW 617-633 15.6 20 16.7 20 - - YSC102A3 187-253 45.1 60 48.2 60 - ' - 81 YSC102A4 414-506 24.0 30 25.5 35 - - YSC102AW 617.833 19.5 26 20.7 25 - - YSC102AK 342-418 29.6. 40 31.1 40 - - YSC120A3 187 -253 62.8 60 66.6 60 - - 10 YSC120A4 414 -508 26.9 35 28.9 35 - - YSC120AW 517-633 21.8 26 23.5 30 - - YSC120AK 342 -418 32.8 40 35.6 . 45 - - 79 • ti 00. • N 0: U) W N LL: W0 g Q. MD' Z : O. .2 D U0 ;0 tn: . W UJ IL f ' • W Z' U N; All dimensions are in inches /millimeters. 3, 4, and 5 Ton Standard Efficiency — Low and Medium Heat 3 and 4 Ton High Efficiency — Low and Medium Heat EVAPORATOR SECTION ACCESS PANEL ALTERNATE CONDENSATE DRAIN CONNECTION 3/4.14 NPT DIA. HOLE III 3, 4, and 5 Ton Standard Efllalency —High Heat 3 and 4 Ton High Efficiency — High Heat 5Ton — High Efficiency — Low, Medium, and High Heat • EVAPORATOR SECTION ACCESS PANEL ALTERNATE CONDENSATE DRAIN CONNECTION 314.14 NPT DIA. HOLE Dimensional Data 4 114' 108 MM 4 1/4' 108 MM 69 7/8 1775 MM 1/2 NPT OAS CONNECTION 23 9118' 598 MM 69 7/8 42 1/4' 1776 MM 1073 MM 1/2 NPT GAS CONNECTION 95/8' 244 MM 8 6/8' 244 MM 6 6/8' 143 MM CONTROL AND COMPRESSOR ACCESS PANEL 55/8' 143 MM CONTROL AND COMPRESSOR ACCESS PANEL (3 5Tons) TOP PANEL 41/4 08MM• 5 9115' 141 MM. 44114' 1124 MM TOP PANEL 41/4 08MM• 75/8' 194 MM 5 9/16' 141/111 75/8' 194 MM 44 114' 1124 MM CONDENSER FAN 32 /4' 819 MM CONDENSER FAN CONDENSER COIL UNIT CONTROL WIRE 7/8' (22MM) DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8' (35MM) DIA. HOLE UNIT POWER WIRE 1 3/32' (28MM) DIA. HOLE 38 /4' 921 MM CONDENSER COIL UNIT CONTROL WIRE 7/8' (22MM) DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8' (35MM) DIA. HOLE UNIT POWER WIRE 1 3/32' (28MM) DIA, HOLE ' 86 RTPRC008•EN All dimensions are in inches /millimeters. 3.5 Tons — Downflow Airflow Supply and Return; Through the Base Utilities :3-5 Tons — Hodzontal Airflow Supply and Return 3.5 Tons — Unit Clearance and Roof Opening RT-PRC006•EN Dimensional Data CLEARANCE 37' (040 MM) CLEARANCE 48' (1210 MM) (s; 5Tons) 3/4.14 NPTCONDENSATE DRAIN TYPICAL ROOF OPENING i 1 • / 337MM 131/4' INK 171/4' 87/8 438MM 225MM 3 3/18' 8IMM 231/4' 581 MM ok HORIZONTAL FLOW • 18' (457 MM) DOWNFLOW 38' (914 MM) 4 3/4' 121MM 44 112' (1130 MM)� CLEARANCE 38' (014 MM) 87 w v ! 0 O y 0 co up (n w; w O` = v; 1— t Z I— O ,Z ; U 0' . 0 H w W. W Z ri 01—t mow Table WI — Maximum Unit And Comer Weights (Lbs) And Center Of Gravity Dimensions (In.) Unit Maximum Weights (Lbs) ComerWeights (Lbs)' Center of Gravity fin.) Tons Model No. Shipping Net A B C • D Length Width 3 YSCO3eA YHCO364 4 YSC048A YHC048A YSC060A YHC060A YSC072A YHC072A YSC090A YSC092A YHC092A YSC102A YHC102A YSC120A YHC120A 7'/2 10 Notes: 1. Corner weights are given for information only. 2. Weights are approximate. 94 572. 480 589 497 597 505 631 614 666 878 735 915 772 963 820 965 822 1066 923 1042 899 1100 957 1063 958 1203 1060 Weights CENTER OF GRAVITY WIDTH 0 CENTER OF GRAVITY 161 158 159 166 169 179 249 249 273 277 306 297 310 317 342 CENTER OF GRAVITY -4- LENGTH -r 124 96 128 101 130 106 133 114 134 105 140 119 193 132 198 141 208 146 222 147 243 165 243 165 252 175 261 177 277 197 Table W2 109 32 19 110 32 19 109 33 19 126 32 20 114 32 18 136 32 20 161 39 21 184 39 22 193 38 22 175 40 21 210 39 22 194 40 21 220 40 22 202 41 21 246 40 22 — Factory-Installed Options Net Weights (Lbs)'•? ) NetWeight Accessory 3 ns 6- 10Tons Economizer 28 36 Barometric Relief . 10 Powered Exhaust — 80 Motorized Outside Air Damper 20 30 Manual Outside Air Damper 16 26 Roof Curb 70 115 Oversized Motor 6 8 Belt Drive Motor 31 — Smoke Detector, Return 7 7 Smoke Detector, Supply .5 5 Coil Guards 12 20 Hinged Doors 10 12 Powered Convenience Outlet 38 38 Through the Base Electrical 8 13 Through the Base Gas 5 6 Unit Mounted Circuit Breaker 5 5 Unit Mounted Disconnect 6 5 8 8.• . Dehumidification (Hot Gas Reheat) Coll 16 25 Novar Control Notes: 1.Welghts for options not listed are < 5 lbs. 2.Net weight should be added to unit weight when ordering factory-installed accessories. RTPRC006•EN . . . , . • • " • • PRO-STAFF® ... FOR YOUR HEATING, AIR CONDITIONING 8 REFRIGERATION NEEDS PROJECT: PRO-STAFF MECHANICAL INC. P.O. BOX 33370, SEATTLE, WA 98133 (206) 361-0071 FAX: 361-0424 PLEASE VISIT OUR WEBSITE AT www.pro-staffmechanical.com COMMERCIAL HVAC CONTRACTORS SYSTEM DESIGN & INSTALLATION SHEET METAL FABRICATION 24 HOUR EMERGENCY SERVICE PREVENTIVE MAINTENANCE DATE: I r,�. / .. . .. . . .. t . r \ , 1 1 . , .. lt '4 ■-ili . , 4 1 1 I N sed i Ll .. ( ,tLJ 1 i I f N.,. 1 ________ ----.1-...,-....- ) i,--. . I 1 t .......-.7 q 4., -..k .. ,,..1 11 I I .. • - 70 i • ...._.„)„, fi � IT . . . , . • • " • • PRO-STAFF® ... FOR YOUR HEATING, AIR CONDITIONING 8 REFRIGERATION NEEDS PROJECT: PRO-STAFF MECHANICAL INC. P.O. BOX 33370, SEATTLE, WA 98133 (206) 361-0071 FAX: 361-0424 PLEASE VISIT OUR WEBSITE AT www.pro-staffmechanical.com COMMERCIAL HVAC CONTRACTORS SYSTEM DESIGN & INSTALLATION SHEET METAL FABRICATION 24 HOUR EMERGENCY SERVICE PREVENTIVE MAINTENANCE DATE: PRO-STAFF® PROJECT: • FOR YOUR HEATING, AIR CONDITIONING & REFRIGERATION NEEDS 1 1 6 " r•?. PRO-STAFF MECHANICAL INC. P.O. BOX 33370, SEATTLE, WA 98133 (206) 361-0071 FAX: 361-0424 PLEASE VISIT OUR WEBSITE AT www.pro-staffmechanical.com COMMERCIAL HVAC CONTRACTORS SYSTEM DESIGN & INSTALLATION SHEET METAL FABRICATION 24 HOUR EMERGENCY SERVICE PREVENTIVE MAINTENANCE DATE: _ _ ... .....--.. -....-...- . ....-.-. ...- ....-...... -,....... . -- .-- lull a ti ) ..,.... 4 ) _ H _ kV I . ........ 1 '11 • ‘=*: 0 >r I I -. 4 i ' t 1; A - 1) ,. _ I • ,)---r o7iN H . r , - ,J)) .- • 1.. \ t - ! 1 6 : ..- 4 A ? 7 ..)-• ‹.t.1 4 3 0 — 7 PRO-STAFF® PROJECT: • FOR YOUR HEATING, AIR CONDITIONING & REFRIGERATION NEEDS 1 1 6 " r•?. PRO-STAFF MECHANICAL INC. P.O. BOX 33370, SEATTLE, WA 98133 (206) 361-0071 FAX: 361-0424 PLEASE VISIT OUR WEBSITE AT www.pro-staffmechanical.com COMMERCIAL HVAC CONTRACTORS SYSTEM DESIGN & INSTALLATION SHEET METAL FABRICATION 24 HOUR EMERGENCY SERVICE PREVENTIVE MAINTENANCE DATE: Light Commercial Retrofit Manager • Copyright 1993 -97 American S'dard, inc. Printed on: 12 03 -2004 )S Trane /AmStd SAHA 50 Trane / AmStd SAHA 50 V N r r . SA )4A --Sv /4 1P v wH I= t4/ General Information: Year: Size (tons): Weight (Ibs.): Heat Type: Gas MBH Out: KW Electric: 1969 -78 5 50 050 Elec or Gas 100 -140 Dimensional Information: Box Size (Inches): Height: Lenght: Width: 33 43 84 Duct Connections: Typical Supply Outlet: Typical Return Inlet: Converted Supply Outlet: Converted Return Inlet: General Information: Year: Size (tons): Weight (Ibs.): Heat Type: Gas MBH Out: KW Electric: Dimensional Information: Box Size (Inches): Height: Lenght: Width: 33 43 84 Duct Connections: 1969 -78 5 950 -1050 Elec or Gas 100 -140 Typical Supply Outlet: Typical Return Inlet: Converted Supply Outlet: Converted Return Inlet: H W 19.00 X 27.00 21.00 X 27.00 10.00 X 37.00 10.00 X 37.00 H W 19.00 X 27.00 21.00 X 27.00 10.00 X 37.00 10.00 X 37.00 The data contained in this program has been gathered from various manufacturer's data catalogues. American Standard does not guarantee its accuracy and as such you should not use this program as a basis of design for a system replacement. r uJ J0; 0 0 N 0 ; NW , 1- ; u. 2 g Lit v_a Z o; H U 0 . O N ;o *al Id ll z t U _F 06 -07 -2005 PETER CREELEY PO BOX 33370 SEATTLE WA 98133 RE: Permit No 1156 INDUSTRY DR TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if . the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/13/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer, Permit Technician xc: Permit File No. M04 -215 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director DEPARTMENTS: •� " 14-7 -n / Building ' isio Public Works ❑ ' PERMIT COORC COP'' PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M04 -215 DATE: 12 -03 -04 PROJECT NAME: THE 13TH REGIONAL CORPORATION SITE ADDRESS: 1156 INDUSTRY DRIVE X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision #_afterThefore permit is issued ( ( 116,- (2 -Zy Fir Prevention [] Structural El Complete d Incomplete ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -07 -04 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R9UTING: Please Route , L � J { Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 01 -04 -05 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing s8p.doc 2-28-02 :` ►MIT COORD COPY • _ • NEW "LIKE- FOR - LIKE" ROOFTOP REPLACEMENT SCHEDULE Service Ste. #1156 MODEL # YSC060A3EMA COOLING COOLING (BA SEER 63,100 1 10.20 � AG AC -3 1 SIZE 5-Ton CFM 1,900 ' MIN OSA 400 HEATING INPUT 80,000 HEATING OUTPUT 64,000 AFUE 81% ELECTRICAL 208 - 230/3/60 MCA = 31.5 FUSE =50 Sound (dB) 84 WEIGHT (LBS.) 555 Men 'skim appwal Is subject to girds and omissions. Approwal of aonwucilon doQ do not autliaYs the vlolrwn of any adopted axle or adism. lisailpt at approved A Cqy and =dlbir It adonwMdpt 7 Cliv 6 %Wm oN EQUIPMENT NOTES: 1. Economizer. 2. Barometric Relief Air Damper. 3. 7 -Day programmable night setback thermostat with 5 degree dead -band capability. 4. Outside air intake to be 10' - 0" from exhaust outlet, gas flues & plumbing vents. 5. Existing Unit being replaced: AC -3: Trane Model SAHA -50, Weight = 950 pounds. - SEPARATE PIERNIT REQUIRED Iola 0 Mechanical Electrkal Pr Plumbing if VGP BUILDING DIMON City Of 9 REVIEWED FOR CODE COMPLIANCE DEC 2 3 2004 City iuKwiW BUILDING DMSION SCOPE OF WORK: Remove & dispose of the existing 5 -Ton AC unit per EPA guidelines • One new Trane Precedent 5 -Ton gas/electric AC unit with economizer. • The gas heat will not be hooked up (piped) at this time. • Equipment start-up & test. ' Eft, es . ' p . kr) 41 tit H iiiiTo i W 13:414 0 W14 N C � A ,s a U kg To 6 'T = = 0114 VI: g:12 O w) O - Ing3126 NO changes shall be made to the BOOM of WO* tvitltout prior approval of Tula'''. Building Division. NOTE: Ravblotli wNl require a new plan submittal .and may Include sddilonM Plan review fees. � DEC 0 3 p004 PERAirr corrER REVISIONS DRAWN Vic : e : 72 / 7 M04-21 5 "u M -1 at Minkler Blvd Site Plan 29 ,.i.r .1 Building #40 Roof Plan CODE COMPLIANCE DEC 2 3 2001 City Of Tukwila BUILDING DIVISION C11'Y pp 'wi DEC 0 3 2004 PERM RCENTE R REPLACE EXISTING 5 -TON AC UNIT WITH A NEW 5 -TON AC UNIT • B � • 3 w W 41111 4t ~ V W14 W W C4 61 i i 4 oa co O r ova Wi 1$ 225 a f& I2i