Loading...
HomeMy WebLinkAboutPermit M03-013 - LOWER JUNCTION - LOT 7LOWER JUNCTION LOT 7 5442 S 750T" STREET M03-01 3 z W -Q� J U O 0 co 0`. w �=. w O. u_Q. co (3 . I- _ ZH 1- 0: Z H. U 'O —: C3 H ww H -. u. w O z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 8733000070 Address: 5442 S 150 ST TUKW Suite No: Tenant: Name: LOWER JUNCTION - LOT 7 Address: 5442 S 150 ST, TUKWILA, WA Owner: Name: SCHERLER ARNOLD Ell Address: 5436 S 150TH ST, SEATTLE WA Contact Person: Name: DON TRYON Address: 14420 SE 84 ST, NEWCASTLE, WA Contractor: Name: P P & S HEATING & A/C INC Address: 12022 98TH AVENUE NE, KIRKLAND Contractor License No: PPSHE * *005C5 Value of Construction: Type of Fire Protection: Signature: Print Name: doc: Mech MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL NEW GAS FORCED -AIR HEATING SYSTEM AND GAS WATER HEATER FOR NEW SINGLE FAMILY RESIDENCE $4,000.00 Fees Collected: $83.56 N/A Uniform Mechnical Code Edition: 1997 Permit Center Authorized Signature: etr ( Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M03 -013 Permit Number: M03 -013 Issue Date: 04/08/2003 Permit Expires On: 10/05/2003 Phone: Phone: 425 255 -6518 Phone: 425 825 -0917 Expiration Date: 02/25/2002 Date: 0 Printed: 04 -08 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 8733000070 Address: 5442 S 150 ST TUKW Suite No: Tenant: LOWER JUNCTION - LOT 7 PERMIT CONDITIONS 9: Manufacturers installation instructions required on site for the building inspectors review. Permit Number: M03 -013 Status: ISSUED Applied Date: 01/27/2003 Issue Date: 04/08/2003 0 0 N0 co w J = CO w = w H = Z � I— O Z w 0 0 0 1- w U_ O ..z w U= O I—. 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be z construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 11: Fuel burning appliances may not be installed in sleeping rooms, U.M.C. 304.5. 12: Appliances which generate flame, spark or glowing ignition, shall be elevated 18 inches above the floor (U.M.C. 303.1.3.). 13: Water heater shall be anchored to resist earthquake (U.P.C. 510.5). I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Conditions M03 -013 Printed: 04 -08 -2003 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Signature: � �- Date: / : A) (2 bet) M03 -013 Printed: 04 -08 -2003 Z W rt J 0 0 0 W o. CO = . J 1 WO < . N cj Z �: I- O Z 2 U 0 N ' 0 1-- W W . ti f" ', O Z U = � O 'F'. Z CITY OF TUKWILA Ihr Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 SITEr;IOCATI (So Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** S f Site Address: Tenant Name: Property Owners Name: ,4r o6/ Sc 4 et At r Mailing Address: $ 7 5, (Std 5 - 7 4-- Name: ,Vey✓ ! ; Yo Mailing Address: l ieliZO SE (4 5'14- E -Mail Address: 4t7 d; , c Company Name: 'i f ) e ofre 4 Mailing Address: A 5o ' (44 Contact Person: .0 lr YO E -Mail Address: Company Name: Mailing Address: Contact Person: )applicationc\pertnit application (1.2003) 1/2003 King Co Assessor's Tax No.: S 6076 l�Lc.II �G City Suite Number: New Tenant: Day Telephone: A.'e c.,.>('e SAL City Fax Number: 'GENE to -- CONTRACTUR°INFORMATF Contractor Registration Number: • 3 ,�� Expiration Date: * * An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT_OFi • R E CORD = �All, trust be wet stamped b "Architect o Re �.: .. ., . Company Name: A% 14 P ....41-c4 1-c t . 4 c-(4 /� Mailing Address: (4�3 ( ( $ /G 5t el(�c/uQ C.a FP 7 City State Zip Contact Person: Gee or Li Day Telephone: '`l5 G ei S3i-ev E -Mail Address: - .ENGINEER OF RECORD .:All plans must be wet stamped. Eng ineer•ofRecord • Page 1 Fax Number: State Floor: ❑ .... Yes ❑ ..No Mei Zip 9 25 6S/e> 7, 0.59 Zip ?G ?e ei State City State Zip Day Telephone: 01' !SS c S4 ieS 2 5 - 5 f Fax Number: 72 5' 6 `r` 57/27 ibes7 City State Zip Day Telephone: 53Z E -Mail Address: Fax Number: efer5 ( 534 Unit Type: Qty Unit Type: Qty Unit Type: Qty . Boiler /Compressor: Qty .. Furnace <100K BTU Air Handling Unit >= I0,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace> I00K BTU ( Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent ( Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind MECHAMCALPE TINE() I ATION 06 -9 -16 MECHANICAL CONTRACTOR INFORMATION ,,c Z 4 1 /Z 61 ?' Ad e._ ecie 1 4 e e1 6.)0 51 Company Name: Mailing Address: // City State Zip Contact Person: ,p• 4 pe efcd e.c Day Telephone: ife !ZS Cy ( 7 E -Mail Address: / � Fax Number: 12 c e5 4 err t Contractor Registration Number: / (7 ��3k /33 ( ( Expiration Date: 6 — /f - 6 3 * *An original or notarized copy o Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): ' t $ 74 l/ 1'`!J f S f 4 C c? OL &Ja - 6r 7/44-, Use: Residential: New ....I. Replacement .... ❑ Commercial: New ....❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas ....tz Other: Indicate type of mechanical work being installed and the quantity below: PERMii .2APPLICATION :NOTES.= Applicable to all per lts in this:applicahon :=: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTFi UZED AGENT: Signature: estt f Print Name: ..o N ( iE k Mailing Address: i Z %applicationstpermit application (1.200)) 1/200) Page 4 City Day T lephone: Date: (—Z7 — ess 657c Zip State Date Application Accepted: 11 1 Date Application Expi Staff Initials: SAS 1 2 S~ W CL g 0 U) J 1 Nu W j D. 0 w = Z H Z uj U ON 0H = W f- O .Z U = O ~ Z Payee: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila TRYON CONCEPTS LLC MECHANICAL - RES PLAN CHECK - RES 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT CC w Parcel No.: 8733000070 Permit Number: M03 -013 6 n Address: 5442 S 150 ST TUKW Status: APPROVED U O Suite No: Applied Date: 01/27/2003 W Ili Applicant: LOWER JUNCTION - LOT 7 Issue Date: __I 1., U) w . ill Receipt No.: R03 -00437 Payment Amount: 83.56 g co D Initials: SKS Payment Date: 04/08/2003 10:19 AM = w . User ID: 1165 Balance: $0.00 Z H _ F- O Z I- w w U� O i 0 1- w TRANSACTION LIST: Type Method Description Amount Payment Check 2945 83.56 O mi l U �. 0 H O Account Code Current Pmts 000/322.100 66.85 000/345.830 16.71 Total: 83.56 7439 04/09 9716 TOTAL 1832.21 Printed: 04 -08 -2003 Z Project: <r/J 9 t c, f(oy4 - /a / iy Type of Ins ction•: ...Z--Or Address: (/ ....1 , S /so sr Date Calle c9 a 3 Special Instructions: / /io- J2lis, ,,1,_ Date Wanted: Z 7 _ D 3 a.m. p.m. Requester: 2' �1d� Phone No: / CZ06S 35 8 ?o y INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 A pproved per applicable codes. COMMENTS: Inspector: INSPECTION RECORD Retain a copy with permit PERM • 44 ,4. (216)431 -3670 Corrections required prior to approval. Date: 4 2_7_42 3 LI S4 "' REINSPECTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pr ect: - 7 , , tiC, kJ/W Typ f Inspection: /,r6 — //r Address: y s. /512 i� Date Called: 4 3 -03 Special Instructions: Date Wanted: am. ti -- 0 7 / ^ d3 p.m. Re uester: Qiti (c C Y 5.5 e /e; INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PERM (206 4 670 Corrections required prior to approval. COMMENTS: C-*G Q y— Vetelt ` v 1nSu(c,4 a-1-- 111Y c, { -p \iP Inspector: Date: / �1 —0 3 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: Date: Project Name: ,/d u./e`/' CITY OF TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431- 3670 .. —mm. -a ._ . ••• -- - FILE COPY -( Residential Heating and Ventilation Compliance Form (Complete Sections I and II for Group R Occupancies 4 Stories or Less) MECHANICAL PERMIT APPLICATION NO.: A403- 013 BUILDING PERMIT APPLICATION NO.: Site Address: �/ -e�' S. (5 5.1 773 A..1 t l 0 I. WASHINGTON STATE ENERGY CODE HEATING DESIGN METHOD (select A, B or C below): A. ❑ System Analysis — W.S.E.C. Chapter 4 (submit documentation) B. ❑ Component Performance Approach — W.S.E.C. Chapter 5 (submit documentation) ❑. Heating System Installed, (check system type below): 1. ❑ Electric Resistance 2. ❑ Electric (forced air) 3. '[ Other Fuels (gas, heat pump) II. WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (select A or B below): Effective: 7/1/02 1. House Square Footage: 2 3 1 2. House Number of Bedrooms: 3. Required Outdoor Air Table 3 -2: Minimum - /00 cfm Maximum - /5' cfm RECEIVED CITY OF TUKWILA JAN 2 7 2003 PERMIT CENTER CITY Of TUKWILA RcVf9 APR - 2 2O3 C. [xi Prescriptive Option — W.S.E.C. Chapter 6 (for prescriptive, complete the following calcu House Square Footage (heated space): 23 65 X 20 BTU /h 47 3 ex Maximum BTU of Heating System Output A. ❑ Ventilation by Performance or Design Method - W.S.V.I.A.Q. Section 302 (submit documentation). B. 21 Prescriptive Ventilation Options - W.S.V.I.A.Q. Section 303 (select one of the following): 1. ❑ Ventilation using Exhaust Fans (Section 303.4.1.) ❑ Exception for outdoor air inlets — Forced air heating system w /interior doors undercut 1/2" 2. ❑ Ventilation integrated with Forced Air System (Section 303.4.2.) 3. ❑ Ventilation using Supply Fan (Section 303.4.3.) 4. ❑ Ventilation using Heat Recovery System (Section 303.4.4.) ❑ Prescriptive Minimum /Maximum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form). .: i•. �:.:::..,... �. k' LwJ�.;::.. 1': r. ui.l i. a(YLt.kuulLiN'S4:..terd,..i,... .., _._�.... >�!._.L4 ".....+i.i .. ...s= 3..L�::. "e. .... •..... •.S.Y.`vi. Floor Area, ft2 Bedrooms Minimum Flex Diameter 2 or less 3 4 5 6 7 8 gy , 25 Min Max Min Max Min Max Min Max Min Max Min Max .5O0 0 47 1 65 98 80 120 95 143 110 165 125 188 140 210 IQ1Ta(i� ' .:.: . cp63� ':;. 70' - , ' :..85:: 128 `. '.100: .150 , ".1 .173, ` -130' ' 195: ,145 218: 1 - 0. 1.... 75 113 90 135 105 158 120 180 135 203 150 225 ` -" -.1101 = 20001: " ;'65: : 98:: 4 '-•80:.: - =120 " r,95'' ' :143= `110' '165' : 125 : 188.• .` 140 '210.' ..155: :'233 2001 - 2500 70 105 85 128 100 150 115 173 130 195 145 218 160 240 z.',.:.:2561=3000 '< ::. ! 75' 413 ' x'90 ' , '135! .' :105': •.158 ': ;120.`: 180:• ::13571 .= 203 •- 150' .225' ' :248' 3001 - 3500 80 120 95 143 110 165 125 188 140 210 155 233 170 255 i ':' .4 85':; =:128: 100:;. ;'150: ?115 :_'‘1711 130' ,:195 :145' 218 X160 '240` 175'= : '263' 4001 - 5000 95 143 110 165 125 188 140 210 155 233 170 255 185 278 : ^'5001- 6000•'•' :. -105 1585 X120:. ::180:' :"135 ' .•203< '150 ` : 161" ";:248? A 80 s •270' ' 195=: ` ;293 6001 - 7000 115 173 130 195 145 218 160 240 175 263 190 285 205 308 : "2: 7001 i >:' ;: • 125': =188' : ^140: :210;', -.:155? '231: `.170: - ; . 255t :.. 185 :. " 278';' 2200` ::300-; `:2157' = ^' 8001 - 9000 135 203 150 225 165 248 180 270 195 293 210 315 225 338 ' ; -.,9000';,'1' :':' '145 :.r ;218' . :1 "° • ;240: : 175. '.263:'.'190-'.:285':..`205:: '::308. ':220' •:.330•: ~:235`.` '_=353: • TABLE 3 -2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) For residences that exceed 8 bedrooms, inc ease the minimum requirement listed for 8 bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 times the minimum. 1. For each additional elbow subtract 10 feet from length. 2. Flex ducts of this diameter are not permitted with fans of this size. Effective: 7/1/02 TABLE 3 -3 PRESCRIPTIVE EXHAUST DUCT SIZING Fan Tested CFM (p 0.25" W.G. Minimum Flex Diameter Maximum Length Feet Minimum Smooth Diameter Maximum Length Feet Maximum Elbows' 50 4 inch 25 4 inch 70 3 "; ..,50:'.1 .. . ... ... .. 5 'inch • 90 :: 5 inch . :100. .. .'3 `'. 50 6 inch No Limit 6 inch No Limit 3 . • :80•. , :''s, •4. inch 2 , NA flinch 20: • 3 . ,.. 80 5 inch 15 5 inch 100 3 • ' . . 80.,:"--';'..%; • . :90 ., . , v. :6 inch •:. NoLiniit .... .3 ,. 100 5 inch NA 5 inch 50 3 ... , ,100.:: ',.., .,. ,a 1, - . 6`inch'i `. i ... ( =45 , .. , inch . .... .. `..: No'Limit,;: ..'.: 3 .,. 125 6 inch 15 6 inch No Limit 3 ..,, .. . 125, • :... , :7,inch '' 70 e: _ .. ,. .•.7•1nch .. .,. ,'.No'Limit .., .. 3';::', . ..• • TABLE 3 -2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) For residences that exceed 8 bedrooms, inc ease the minimum requirement listed for 8 bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 times the minimum. 1. For each additional elbow subtract 10 feet from length. 2. Flex ducts of this diameter are not permitted with fans of this size. Effective: 7/1/02 TABLE 3 -3 PRESCRIPTIVE EXHAUST DUCT SIZING P.P. & S. Heating & A/C Inc. 12022 98th Ave. NE Kirkland, WA 98034 rfLE COPY 1 136- Doff E n14 3qsve FoR_ l 4 /4 ') c S7adcm I avo "1"\IF'f- c u . rr tz A.E.M G#S FugAlkci_ 'r r.14 /si piicciv1 50. G4-_S MAC -' t om. Writ oL,,lf T 5 t�Um? cy¢ uMJirs; CITY OF TUK ij APPROVED APR - 2 20003 NUiLb RECEIVED CITY OF TUKWIIA JAN 2 7 2003 PERMIT CENTER MOOi3 T Y Model P Numbert E ' Gas Input I Tank iin Thousands Recovery in Cap BTU /Hr. g0' Rise First Hour Delivery . ; Apps• Roughing in Dimensions Rating `Energy i Shpg. (Shown in Inches) G.P.H. ' Factor ;Wght.. Lbs. ' Gals. . LP • Nat. ;Burner' Nat. LP Nat. LP A: B C 0 i 6! F' 0 H 41VR40 40 40 40 40.4 40.4 68 • 68 0.62 127 .61 % 158% 21 8 ; 3 13% 2 'A T 41VR40N• 40 37.5 — 40.4 — 68 — 0.62 127 .61 % ; 58% ; 21 8 , 3 ; 13% . 2 'A I- h?.41VR50` : ' O ,I 40 ' I•:40 ! 40.4 40.4 ' t5 74. 74 1 0.62 1 151 160% 157% 123 8 3 1 13% ; 2 I %x 2 . 'A 2 % 2 % 2 41 VR50N' 50 40 — 40.4 — 74 — 0.62 151 60% 57% 23 8 3 ; 13''h ' 41V30S 30 34 34 34.4 34.4 40 37 37 37.4 37.4 50 40 40 404 40.4 54 54 0.58 109 50'/ 46% • 17% 8 ' 3 • 13'/% 13W 41V40S 41V50S" 65 65 0.56 138 52% .48% 19% 8 3 13% 73 73 0.53 140 54 48 %'22%+ 8 3 13% GM' OF Ti a ILA AftPrlyEo Available in 40 and 50 gallon tall _ ,, 30 and 40 gallon lowboy models i,. alt:; t „ ,; u • 5 -Year Limited Tank Warranty* • 1 -Year Limited Parts Warranty* • High performance and recovery • Patented R -Foam® insulation process for JAN 2 7 2003 superior heat retention PERMIT CENTER • Gasmaster'" burner with precision port alignment for even heat transfer • Heat saving flue baffle design • Compliant with many gas utility incentive programs ** • Meets or exceeds National Appliance Energy Conservation Act (NAECA) requirements 'See Residential Warranty Information Brochure for complete warranty information. "40.000 BTU models only. SPECIFICATIONS RHEEMGLAS Fury Pius High Performance, Energy Miser® PI, r( r)v Gas Water Heater RECEIVED CITY OF TUKWILA ' For SCAOMD rule 1121 compliance (California only) • Side rebel valve connection on model 41V50S only. Specify LP gas when ordering. Add "P" suffix to the model number. Example 41VR4OP 1403013 . riW+i:d4Y.'dladi'r_(�•Lv�i. �}::1dsiv7ii.W YiT THESE UNITS ARE DESIGNED TO MEET OR EXCEED A.N.S.I. (AMERICAN NATIONAL STANDARDS INSTITUTE) AND HAVE BEEN TESTED ACCORDING TO D.O.E. TEST PROCEDURES AND MEET OR EXCEED THE ENERGY EFFICIENCY REQUIREMENTS OF NAECA, ASHRAE STANDARD 90, BOCA CODE AND ALL STATE ENERGY EFFICIENCY PERFORMANCE CRITERIA FOR ENERGY CONSUMING APPLIANCES. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. The number one choice of plumbing professionals. RHEEM WATER MANUFACTURING HEATER COMPANY DIVISION 101 Bell Road. P.O. Box 244020. Montgomery, Alabama 36124.4020 PRINTED IN U.S.A 3.97 WP RHEEMGLAS® Fury Plus Energy Miser CONSTRUCTION FEATURES 1. R -Foam Insulation —Rigid polyurethane foam for improved economy and fuel savings. The use of our patented insulator foam stops allows R -Foam to be injected directly between the tank and outer jacket. This uniform R -Foam application minimizes the possibility of costly heat loss caused by uninsulated areas (voids) common to some other foam processes. 2. Rheemglas Tank— Rheem• water heater tanks are made of special materials with exacting care. The tank surface is coated with an exclusive porcelain formula called Rheemglas and fused to the solid steel at 1600'. The result is a smooth, tough, glass -like lining that effectively resists the corrosive attacks of hot water chemicals, thereby assuring long water heater life. Tank is designed and tested to withstand 300 PSI hydrostatic test pressure for working pressure of 150 PSI, A.N.S.I. Standard. 3. Gasmaster Burner — Durable aluminized steel construction. Designed for efficient, quiet operation; precision port alignment; even heat transfer. Factory adjusted for natural gas. LP models feature a durable stainless steel burner designed specifically for LP gas. 4. Flue Baffle —New design — special baffle restrictor discs provide greater retention of flue gases. Keeps heat in flue longer for maximum heat dispersion to tank water. Retards air movement through flue during standby periods, minimizing heat loss. 5. Robertshaw• Control— Combination thermostat with factory preset balanced pressure regulation and built in E.C.O. (energy cut -off). LP models feature the R65RR control, the most advanced LP gas control available. 6. Anode Rod — Equalizes aggressive water action; different types factory installed and designed to match local water chemical characteristics throughout the U.S. 7. Dip Tube —A durable plastic formula, tougher, more heat resistant than ever before. 8. Relief Valve Opening—(Ye N.P.T.) top connect is exposed for faster, economical installation. 9. Drain Valve —Non- metallic, corrosion proof, designed for quick draining. 10. The Draft Diverter —Low profile design is proven, efficient. THE GASMASTER BURNER Durable aluminized steel construction. Designed for efficient, quiet operation; precision port alignment, even heat transfer. Features energy saving low input pilot — only 350 to 400 BTUH. Well protected to maintain alignment, yet easy to light. in keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice" FORM NO 101.9 REV. 9 14) RGLH- SERIES Models with Input Rates from,, 45,000 to 150,000 BTU/HR [13 to 44 kW] (U.S. & Canadian Models) ENERG71UIDE vnr um... srr,• AR/E MN Mal /vs on w .n p x' ) 11✓ - � v2)'I L a (Fr INNCY RATING CERTIFIED ama CRITERION® II 78 % -80% A.F.U.E.' DOWNFLOW GAS FURNACES The Rheem® Criterion® II line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by the American Gas Associa- tion. Canadian models are certified by the Canadian Gas Association. Features • Patented Turbulex® heat exchanger, constructed of both stainless and aluminized steel for the maximum in corro- sion resistance. ■ Low profile "34 inch" [864 mm] design is lighter and easier to handle, and leaves room for optional equipment. • Both standing pilot and hot surface ignition models available. ■ Left or right side gas and electric inlet connections with quick, simple change. • Hot surface ignition models feature a new integrated board with humidifier and electronic air cleaner hookups. us-Insulated blower compartment, a slow -open gas valve and a specially designed draft inducer motor make it one of the quietest furnaces on the market today. • Pre -paint galvanized steel cabinet. ■ Grab -holes in doors to aid in easy door removal and replacement. A variety of cooling coils and plenums designed to use with Rheem Criterion II gas furnaces are available as optional accessories. A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy lest procedures. Mo3-a3 FORM NO. G11 -449 REV, 2 Supersedes Form No. G11 -449 Rev. 1 ES RECEIVED CITY OF TUI.WILA JAN 2 7 2003 PERMIT CENTER J z W J O 0 co J = co LL W o g Q d I- W z = W U • 0 O — 0 I- W W • O Ili U O ~ z Draft Inducer Motor Hot Surface Ignitor with Remote Sense (Hot Surface Ignition Models) STANDARD EQUIPMENT RHEEM CR. 1'ERION I 78 -80% DOWNFLOW GAS FURNACE Pilot Assembly (Standing Pilot Models) Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on /time off blower control; limit control; manual shut -off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi - speed blower motor, Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; H.S.I. only twinning options, standing pilot models may 09S be twinned; fused transformer (secondary), 3rd speed option for continuous fan; common heat/cool terminal for H.S.I. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local installer. Molded Permanent Filter Blower and Control Box ors Integrated Furnace Control In -Shot Burners and Gas Valve Turbulex• HeatExchanger All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519 -53 for Canadian models. NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition is 100% lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 7.71. z W lr L 0 0 co W J F— rn lL W LLQ N � W z = H O z t— w w U O O-- 04— 0 W H . z W U 0 h- z � ; - w. 1 .. c `. ';: le °-, ' ",,:, MODEL IUMBERS ; } ,, RGLH= SERIES , , ' ' , ; .- ' � '" + w:� ; ,. ' y " , J 4.. : ' O41NAUSR OgEAUSR 04NAUSR.. 645AUSA'• d4.EAUSA poSOAUER' ' O 5]VMAUUER tO5EAUER 05NAUER : 05OAUEA . � O5EAtJEA ilO67AUER . "O6MAUER A ObEAlU _ 60000 , 'O _1 • 06EbU ; Q75AUERk Oi'MAUEA. /EAUER. , NAUER, 75A ' ,A7EA ';i.075AMGR^ 107MAMGR ,07EAMGR 07NAMGR j t075AMG ; gO7EAINGA 4100AUER �' !w>.1OMAUE . :10EAMER".. `,i +1ONAMER : 1�OOAUEA . 1OEAMEA , . 1OOBRJR� 1OEM ,OEBRJRg , 1ONBRJR+ . OoUtJ A ' OEBRJA 1125ARJR ' . '1 ,2EARJR 12NARJ ' ' 25A iJA i ION 125,000 [36.6] ; 150ARJR:;1 J 15[VIARJfi ; ; 5EARJR. j'',] 5t1ARJI{'`•'q ` ;' . 5OA JA' , 014: 150,000 [44] Input - BTU /Hr [kW] 0 45,000 [13] 50,000 [15] 67,500 [19.8] 15;OOQ [22] 75,000 [22] 100,000 [29.3] 100,000 [29.3) Heating Capacity BTU /Hr [kW] O 36,000 [11] 41,000 [12] 54,000 [16] 60,000,[1,51 60,500 [18] 80,000 [23] 81,000 [24] 99,000 [29] 120,000 [35] High Altitude Input [kW] 40,500 [11.9] 45,000 [13] 60,800 [17.8] 67,500 119.8] 67,500 [19.8] 90,000 [26.4] 90,000 [26.4] 112,500 [33] 135,000 [39.6] High Altitude Output Capacity [kW] 32,900 [9.6] 36,500 [10.7] 49,000 [14.4] 53,500,11 . , ._ 54,000 [15.8] 72,000 [21.1] 72,500 [21.2] 89,000 [26.1] 107,500 [31.5) Heat Ext. Static Pressure [kPa] .10 [.025] ..10 [.025] .12 [.029] .12 [.0291 .12 [.029] .15 [.037] .15 [.037] .20 [.05] .20 [.05] .t_:'. ' 11 x 6= 10*AU Blower (DxW)[mm] 11x6 [279 x 152] 11x6 [279 x 152] 11x6 [279 x 152] 11+6' [279 1 ,52] 11x7 [279 x 178) [279x152] 11 [279 x 8 10'AM [ 11x10 [279 x 254] 11x10 [279 x 254] 11x10 [279 x 254] Motor H.P. [WI- Speeds [WI- 1 /2 -4 -PSC 1 /2.4 -PSC 1 /2 -4 -PSC 1 /2 -4 PSC 3 /4 -4 -PSC 1 /2 -4 -PSC 3 /4 -4 -PSC 3 /4 -4 -PSC 3 /4 -4 -PSC PSC Type [373] [373] [373] [37$1i [559] [373] [559] [559] [559] Motor Full Load Amps 7.1 6.8 7.1 i 7, j 9.5 7.1 9.5 9.5 9.5 Heating Speed MED-LOW MED-LOW MED-HIGH MED;I H MED-LOW MED-HIGH MED-LOW MED-LOW MED-LOW Cooling Speed HIGH HIGH HIGH 'MEG H MED -HIGH HIGH MED -HIGH MED -HIGH MED -HIGH Cooling CFM @ .5' [kPa] E.S.P. 1200 1200 1200 12b0 1600 1200 2000 2000 2000 (Nominal) [Us] [566] [566) [566] ; [566], [755] [566] [944] [944] [944] Rated E.S.P. (In. W.C.) [kPa] .50 [.12] .50 [.12] .50 [.12] .50 1.12) .50 [.12] .50 [.12] .50 [.12) .50 [.12] .50 [.12] t 1 A! 55-85 55 -85 =10'AU Temperature Rise Range °F 30 -60 25 -55 30 -60 ;10 =70; 25 -55 [30.6 -47.2] 40 -70 40 -70 50 -80 [ °C] • [16.7 -33.3] [13.9 -30.6] [16.7 -33.3] [22.38.9] [13.9 -30.6] 45 -75 = 10*AM [22.2 -38.9] [22.2 -38.9] [27.8 -44.4] A ".t r [25 -41.7] Max. Outlet Air Temp. °F 155 155 165 . 165 155 190 190 180 190 [ °C] [68.3] [68.3] [73.9] tgZ3.9J [68.3] [87.8] [87.8) [82.2] [87.8] Standard Filter [mm] (1) 14 x 20 [356 x 508] (1) 14 x 20 [356 x 508] (2) 12 x 20 [305 x 508] (2)12120 [305i 508] (2) 12 x 20 [305 x 508] (2) 12 x 20 [305 x 508] (2) 14 x 20 [356 x 508] (2) 14 x 20 [356 x 508] (2) 14 x 20 [356 x 5081 Approx. Shipping Weight (Lbs.) 85 85 105 105 105 115 120 140 150 [kg] [38.6] [38.6] [47.6] .447.6). [47.6) [52.2] [54.4] [63.5] [68.0] AFUE- Standing Pilot Models 0 78% 79.5% 78.4% 78.6% 79.2% 78% 78% 78.1% 78.5% AFUE- N.S.I. Models 0 81.1% 82.2% 80.7% 3 81.1% 80.2% 80% 80% 80% California Seasonal Efficiency- H.S.I./No, Models 73.8/73.9 75.9/76.2 73.8/73.9 74.4/74.9 75.1/75.5 75.2/75.2 74.7/74.7 75.2/75.3 76.0/75.9 c� BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS NOTES: All models are 115V, 60HZ,10. Gas connection size for all models is 1/2' N.P.T. 0 In accordance with D.O.E. test procedures. p See Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519 -53 for Canadian models for high altitude derate. MODEL IDENTIFICATION- DOWNFLOW MODELS R G L H - Rheem Gas Downflow Design Heating Input Designation Variations Blower Heating & Cooling Fuel Type Furnace Series Standing NOx Electric NOx Input A = Std. Designation Designation 'R . =Natural Gas, Pilot Model Ignition Model BTU /HR Cabinet U = 11 x 6 S = 500 -1200 CFM . .,.U.S. Standard 045 04M 04E 04N 45,000 [13 kW] B = Wide [279 x 152 mm] [236 -566 Usj Furnace 050 05M 04E 05N 50,000 [15 kW] Cabinet M =11 x 7 E- .1100 -1330 CFM A = Natural Gas, 067 06M 06E 06N 67,500 [20 kW] [279 x 178 mm] ''[519 -628 Us] ' Canadian R =11 x 10 G = 1450-1750 CFM Standard 075 07M 06E 07N 75,000 [22 kW] 100 10M 10E 10N 100,000 [29 kW] [279 x 254 mm] [684-826 8 0 20 /s] Furnace J = 1800-2075 CFM 125 12M 12E 12N 125,000 [37 kW] [850 -979 Us] 150 15M 15E 15N 150,000 [44 kW] [ ] Designates Metric Conversions 07E A U E A r--- -, 14 • " [19 mm) 34" [964 [326] 26 /e" [264] [676 mm] + /2" DIA. (13 mm] - 1 /e" DIA. [22 mm) (676 mm) mmj 23 (594 ,,. ��~1:ati.'.. 0 LOW VOLTAGE , '' • " l a l , . 11 : :4,��! her. 0 1 11,•1 ' 1 �Mw ?:lt (f� a i 1 ... R4�.+n.l,., ,,_�S^ <f2A 1+�. [25] 3 [76] 6 [152] 0 mmj , `"-.: C i3 [38.6] • / mm] ELECTRICAL CONNECTION (HIGH VOLTAGE) 2613/1? _ 20 /e' [518 mmj [415] 23 [594 mm) 0 0 - 11 - 11-1 i 1 i t i i i 'I iI II i 1 • - ! - ! - - ___. [681 mm] [422] 0 203/e" (518 mm] 0 +- - [621 [25] 3 63 / te " 11157 mm] 1 DIA. [35 mm] GAS CONNECTION 6 •" [157 mm] 4 [47.6] ... 04, 05 14 [356] 12 [326] 10 [264] . t . O - 131/e ? •. [333] ,,. ��~1:ati.'.. 0 ; . , " - ._• " 4 O , '' • " l a l , . 11 : :4,��! her. 0 1 11,•1 ' 1 �Mw ?:lt (f� a i 1 ... R4�.+n.l,., ,,_�S^ <f2A 1+�. [25] 3 [76] 6 [152] 0 '. 1 ._. 85 , `"-.: C i3 [38.6] 06, 07 17 [445] 16 [415] 12 [308] O 16 [422] 0 3 0 0 1 [25] 3 [76] 6 [152] CD 105 [47.6] 10 (A) 17 [445] 16 [415] 12 [308] O 16 [422] 0 3 9 0 1 [25] 3 [76] 6 [152] CD 115 [52.2] 10 (8) 21 [533] 19 [504] 13 (352] CD 20 [511] 0 0 0 1 [25] 3 [76] 6 [152] CD 120 [54.4] 12 24 [622] 23 [593] 15 [397] O 23 [600] 0 0 0 1 [25] 3 [76] 6 [152] 0 140 [63.5] 15 24 [622] 23 [593] 15 [397] CD 23 [600] 0 0 . 0 1 [25] 3 [76] 6 [152] CD 150 [68] NOTES: m May renuire a 3' 176 mml to 4' f102 mml or 3' 176 mml to 5' f127 mm) adapter. DOWNFLOW DIMENSION° LEFT SIDE r 1 rloalnnatne 1111estrin r nminralena 5 /e" (16 mm] TOP FRONT BOTTOM S.A. +— 5 /e" [16 mm] 7 /1e" 19 (502 mm] 3 /4" [19 mm] TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] RIGHT SIDE m May be 0' [0 mm] with type B vent. m May be 1' [25 mm] with type B vent. Furnaces must be vented In accordance with ANSI 221.47 -1993 • CAN /CGA- 2.3 -M93 venting table guidelines Included with each furnace, and In accordance with local codes. Z Z . ~ W tY 2 6 JU 00 NO CO V) 11J Ill I W u- N O = W = Z F. ZO UJ W UO O N ro W I"- t; = O ~ Z BLOWER 045AUS' 04MAUSR 04EAUS* 04NAUSR PERFORM 11 x 6 [279 x 152] 1/2 [373] ':: . � +r � �.: LOW MED -LO MED -HI HIGH NCE DATA- . .r A , ;;` ' .� :�� .. , ... i. ..:: � 685 (323] 980 [463] 1220 [576] 1465 [691] D0WNFLOVVI0DELS S UR C ESI -...; �0�.:r, . :y { '; .. rig 580 [274] 900 [425] 1135 [536] 1365 [644] I';1 470 [222) 805 [380] 1020 [481] 1230 [580] .fi ;, :05 ,rx • s::r., -� 650 [307) 955 [451] 1195 [564] 1440 [680] .r l07 's:.! ' � 615 [290] 930 [439] 1170 [552] 1405 [663] .,. ;. � �}' �����' `� 545 [257] 870 [411) 1100 [519] 1325 [625] ? 2:? 510 [241] 840 [396) 1065 [503] 1280 [604] 050AUE* LOW 735 [347] 715 [337] 690 [326] 660 [311] 635 [300] 605 [286] 575 [271] 05MAUER 11 x 6 1/2 MED -LO 1025 [484] 1015 [479] 995 [470] 975 [460] 955 [451] 930 [439] 905 [427) 05EAUE• [279 x 152] [373] MED -HI 1185 [559) 1165 [550] 1150 [543] 1130 [533] 1100 [519] 1075 [507) 1040 [491] 05NAUER HIGH 1345 [635) 1330 [628] 1310 [618] 1295 [611] 1265 [597] 1235 [583] 1205 [569] 067AUE' 06MAUER 06EAUE' LOW 835 [394] 820 [387) 800 [378] 775 [366] 750 [354] 720 [340] 685 [323] 06NAUER 11 x 6 1/2 MED -LO 990 [467] 975 [460) 955 [451] 935 [441] 905 [427) 875 [413) 835 [394] 075AUE' [279 x 152] [373] MED -HI 1140 [538] 1125 [531] 1105 [522] 1080 [510] 1050 [496] 1020 [481) 980 [463] 07MAUER HIGH 1300 [614] 1290 [609] 1265 [597] 1245 [588] 1215 [573] 1180 [557] 1140 [538] 07EAUE' 07EAUER 075AMG* LOW 1210 [571] 1205 [569] 1195 [564] 1180 [557] 1165 [550] 1155 [545] 1130 [533] 07MAMGR . 11 x 7 3/4 MED -LO 1580 [746] 1560 [736] 1550 [732] 1530 [722] 1495 [706] 1465 [691] 1430 [675] 07EAMG* [279 x 178] [559] MED -HI 1915 [904] 1880 [887] 1825 [861] 1790 [845] 1740 [821] 1675 [791] 1600 [755] 07NAMGR X• .. - ,.,-"r .. - ' -r7 ��...- HIGH r I !/- 1 — - - . fill 2050 [967] :•'f i1.•. �Ja•-. 1995 1995 [942] 1940 [916] � ., .'. * �'R012 1885 [890] p� •`a pi 1835 [86 6] 7 ... . MIS& 1770 [835] �7V591k? :: . 'evt: 10EAME" 11 x 7 1/2 MED -LO 1070 [505] 1055 [498] 1040 [491] 1010 [477] 980 [463] 945 [446] 905 [427] 10NAMER [279 x 178] [373] MED -HI 1240 [585] 1210 [571 ] 1190 [562] 1165 [550] 1135 [536] 1095 [517] 1055 [498] HIGH 1420 [670] 1395 [658] 1370 [647] 1340 [632] 1305 [616] 1265 [597] 1220 [576] ]IALLSO RE11 a @5]10:67.9➢1i[3Z31111111fiONM1" lal6{a971ra 100AUE• 11 x 6 1/2 MED -LO 1020 [481] 1000 [472] 980 [463] 965 [455] 930 [439] 895 [422] 860 [406) 10MAUER [279 x 152] [373] MED -HI 1170 [552) 1160 [547] 1140 [538] 1110 [524] 1080 [510] 1040 [491] 995 [470] HIGH 1330 [628] 1300 [614] 1270 [599] 1235 [583] 1200 [566] 1160 [547] 1115 [526) 100BRJ' LOW 1330 [628] 1295 [611] 1285 [606] 1245 [588] 1225 [578] 1205 [569] 1160 [547] 10MBRJR 11 x 10 3/4 MED -LO 1690 [798] 1670 [788) 1655 [781] 1615 [762] 1585 [748] 1565 [739] 1525 [720] 10EBRJ" [279 x 254] [559] MED -HI — 2085 [984] 2055 [970] 2005 [946] 1970 [930] 1945 [918] 1880 [887) 10NBRJR HIGH — 2410 [1137] 2355 [1111] 2305 [1088] 2240 [1057] 2165 [1022] 2100 [991] 125ARJ" LOW 1330 [628] 1295 [611] 1280 [604] 1240 [585] 1215 [573] 1210 [571] 1175 [555] 12MARJR 11 x 10 3/4 MED -LO — 1690 [798] 1660 [783] 1635 [772] 1580 [746] 1535 [724] 1480 [698] 12EARJ" [279 x 254] [559] MED -HI — 2090 [986] 2035 [960] 1985 [937] 1930 [911] 1850 [873] 1785 [842] 12NARJR HIGH — 2395 [1130] 2335 [1102) 2260 [1067] 2185 [1031] 2080 [982] 1965 [927] 150ARJ* LOW 1300 [614] 1280 [604] 1230 [580] 1205 [569] 1170 [552] 1115 [526] 1030 [486] 15MARJR 11 x 10 3/4 MED -LO 1675 [791] 1650 [779] 1620 [765] 1570 [741] 1545 [729] 1485 [701] 1425 [673] 15EARJ" [279 x 254] [559] MED -HI 2105 [993] 2075 [979] 2035 [960] 1990 [939] 1955 [923] 1900 [897] 1815 [857] 15NARJR HIGH — 2340 [1104] 2290 [1081] 2215 [1045] 2145 [1012] 2080 [982] 1995 [942) NOTES: 'Designates "R" for U.S. models. and "A" for Canadian models. "Not to be used as a heating speed. Data compiled with factory filters installed. [ ] Designates Metric Conversions • Z W re 6 6 00 W H V) u_ W 2 ga to 3 � W Z I— 0 W H W U� 0— 0 I— w H- U_ O W 0- 0 I" Z �1 IA0.11 ASEE ? if F URNACE ! SIZES '4 ",; IN, � m m s H B mm j [ mtn r RXGC -B14 RGLH -04, 05 14 [368] 13 [337] 11 [286] RXGC -B17 RGLH -06, 07, RGLH- 10( -)A 18 [457] 16 [425] 14 [451] RXGC -B21 RGLH- 10( -)B 21 [546] 20 [514] 18 [464] RXGC -B24 RGLH -12, RGLH -15 25 [635] 23 [603] 21 [552] FURNACE=it .; �IDTN!�`,' N ,;[mm1� Y ` '% PLENUMS' ' ' {WIDTH ,SIN II i1 h as>1 * P Ol t -' i i - ' Z - ' Olu ,... 14 [356] 16 [413] RXAA -C178 RXAL -B16BU 14 [356] 20 [514] RXAA -C179 RXAL -B20BU 17 [445] 16 [413] RXAA -C186 RXAL -B16BU 171/2 [445] 20 [514] RXAA -C180 RXAL -B20BU 17 [445] 215 /8 [549] RXAA -C189 RXAL-B21BU 17 [445] 25 [641] RXAA -C181 RXAL -B25BU ' 21 [533] 22 [565] RXAA -C182 RXAL -B22BU 21 [533] 25 [641 ] RXAA -C183 RXAL -B258 U 24 [622] 25 [641 ] RXAA -C184 RXAL -B25BU 24 [622] 21 [549] RXAA -C190 RXAL-B21BU ACCESSORIES -DOWN r` OW 'DOWNFLOW WARNING: Unit design is certified for installation on non -corn- - buslible floor. A special factory supplied combustible floor sub -base is required when installing on a combustible floor. Failure to install the sub -base may result in fire, property damage and personal Injury. COMBUSTIBLE FLOOR BASE DIMENSIONS 1 PRINTED IN U.S.A. 19 [495 mm) [51 mm) 2" 28 (721 mm) FIBERGLASS 3 LB. [1.4 kg] DENSITY Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. 8-96 BP 7 (164 mm] 4" (102 mm 1 : . ,r 134/19 3" [76 mm] � /2" [546 21 mm) - r 3" (76 mm] NOTE: FLOOR OPENING 21 546 mmj x B MAX. PLENUM SIZE 19 [495 mmj x C RHEEM AIR CONDITIONING DIVISION PLENUM DATA — "A" COILS Plenum adapters are required in some instances for use on downflow applications . when plenum and furnace size do not match. NOTE: See Form Number C11 -206 for MultiFlex coil data. RXGW -AAA01 Humidifier and Electronic Air Cleaner Accessory Board for Robertshaw Control RBC1 and Honeywell ST9101A 1014 Blower Controls. NOTE: Available for standing pilot models only. tJ ri FIBERGLASS 3 LB. (1.4 kg] DENSITY PLENUM OR DUCTWORK P.O. Box 17010, Fort Smith, Arkansas 72917 -7010 RXPF -F01 and F02 FOSSIL FUEL KIT —is for use with Rheem Heat Pumps and Criterion II warm air furnaces. RXPF -F02 meets TVA requirements. RXGF -CC* FILTER RACK — Downflow top return mount. NOTE: Filter racks are shipped without filters. 'Filters available through the Universal Parts® Department. GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Gas Heat Exchanger Limited Warranty Twenty (20) Years Draft Inducer Limited Warranty Five (5) Years Integrated Control Board Limited Warranty Five (5) Years (Standing Pilot and Hot Surface Control Boards) Any Other Part One (1) Year 'For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. "In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice." FORM NO. G11 -449 REV. 2 Supersedes Form No. 011.449 Rev. 1 A • PERMIT Cr■Pnr r. PLAN REVI EWIROUTI NG SLIP ACTIVITY NUMBER: M03 -013 PROJECT NAME: LOWER JUNCTION - LOT 7 SITE ADDRESS: S 150 STREET X Original Plan Submittal Response to Correction Letter # DATE: 01 -27 -03 Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: p,�,� 'Z -12 iii. Z Builtii"ng Dlvlslon Fire Prevention (� Public Works [] Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete APPROVALS OR CORRECTIONS: Incomplete Approved ❑ Approved with Conditions REVIEWER'S INITIALS: Documents/routing slip.doc 2.28 -02 Planning Division Permit Coordinator DUE DATE: 01-28-03 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route R Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 02-25 -03 Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z If W 6 = 00 co W u. W O u - = d I w Z = I— O Z H W U� O -. W H0 U- 111 Z U= O~ z REGISTEREDAS PROVIDED BY LAW AS CONST CONT GENERAL ;; ;REGIST • # EXP . DATE ,'CCO1`_ TRYONCL013DH 02/11/2005 EFFECTIVE. DATE 03/08/1999 i TRYON CONCEPTS LLC PO BOX 146: RENTON.WA. 98057 Issued by DEPARTMENT OF LABOR AND INDUSTRIES Signature •