HomeMy WebLinkAboutPermit M03-019 - FOSTER GOLF COURSE - CLUBHOUSE' I FOSTER GOLF LINKS CLUBHOUSE 13500 INTERURBAN AVENUE SOUTH M03-019 • Parcel No.: 0003000049 Address: 13500 INTERURBAN AV S TUKW Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: RICK STILL Address: 12424 42 AV S, TUKWILA, WA Contractor: Name: WADE PERROW CONSTRUCITON LLC Address: P.O. BOX 1728, GIG HARBOR WA Contractor License No: WADEPCL982R7 Value of Construction: $147,465.00 Type of Fire Protection: SPRINKLERS Permit Center Authorized Signature: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 FOSTER GOLF LINKS 13500 INTERURBAN AV S, TUKWILA, WA TUKWILA CITY OF 6200 SOUTHCENTER BLVD, TUKWILA WA MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 767 -2344 Phone: Expiration Date: 12/27/2004 DESCRIPTION OF WORK: INSTALLATION OF NEW HTG /REFRIGERATION SYSTEM, VENTILATION FANS, HOOD AND OTHER MECHANICAL EQUIPMENT FOR NEW CLUBHOUSE /RESTAURANT M03.019 M03 -019 06/25/2003 12/22/2003 Fees Collected: $475.31 Uniform Mechnical Code Edition: 1997 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio or the performance of wo I am authorized to sign and obtain this mechanical permit. Signature: CJ /--(0 ,, Date: Print Name: a( -1 e_� CJ . ['owe/ /.5' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 06 -25 -2003 ■ z F Lu 6 00 . J F— U) w tn Z = F- O z F- w.w U � O N o w W I u- W z - z 0 1- z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 0003000049 Permit Number: M03-019 Address: 13500 INTERURBAN AV S TUKW Status: ISSUED Suite No: Applied Date: 02/04/2003 Tenant: FOSTER GOLF LINKS Issue Date: 06/25/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 13: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 14: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1900. 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the doc: Conditions M03 -019 Printed: 06 -25 -2003 z a• Z � 0 rn W J U LL uj 0 1_ D. a I I z � 1.0 Z I- w ON 0H wW 1-- O to ..z O z manufacturer's installation instructions. (UMC 608) 16: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 18: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 19: Duct detectors shall send a supervisory signal only upon activation. 20: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 21: Local U.L. central station supervision is required. (City Ordinance #1900) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 23: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) 24: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 26: WA State Nonresidential energy code Section 1416.4.2.3 THIS BUILDING SHALL NOT BE ISSUED A FINAL CERTIFICATE OF OCCUPANCY UNTIL SUCH TIME THAT THE BUILDING OFFFICIAL DETERMINES THAT THE PRELIMINARY COMMISSIONING REPORT REQUIRED BY THIS SECTION HAS BEEN COMPLETED. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: • ( Print Name: S - 1.eac. • � o doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 M03 -019 Date: 6 / z `' (° 3 Printed: 06 -25 -2003 Contact Person: E -Mail Address: Company Name: Mailing Address: \aPPlicationc\prnnil application (1.2007) 1/2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 King Co Assessor's Tax No.: 0003Qo — 0 04 ° t Site Address: 135 IR VmaAN ACV ' S • Suite Number: Tenant Name: FO STER 6 .0L F Li N KS New Tenant: 0 .... Yes g..No Property Owners Name: CITY' o F T1J K w tL)s. PA{2K 1 s 4 Ra:GRe ©N Mailing Address: 124 24 - s yy ir 2N .,t t D AV • S S. " Kum.-p.. wk City DAi t t r 4 . c c.AR K Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** • SITE.LOCATION . • Name: 1Z (C K STt L L Mailing Address: 12-4 24 - 42 l 2 1 . S. E -Mail Address: {ZSTILLe CI.TUkW(L wA.US I1"737 SE 2 S-" Contact Person:bkE CLAW Mk E -Mail Address: DCLARK(PCLO RK tfI i c'ts, ca tM t -Cr5, PL.LC Contact Person: CI, M2l4 e-fN &Old Pe" E -Mail Address: oFFIck Joim SaNeNCI News . coM Page 1 State State Floor: 98 r68 Zip Day Telephone: 20co^ 761— 23 44 -'U Kw( LA- t� R 816 City State Zip Fax Number:2oG -767 - 234 I Company Name: Mailing Address: Zip City Day Telephone: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT.. OF RECORD. - Al! plans must tie. wet stamped b Architect of Record PLACE ANT kW A- 98630 -1697 City State Zip Day Telephone: 2C3-81-8297 1 Fax Number: '21 — €S4 " 7€ 'ENGINEER OF RECORD -MI plans must be Wet stamped by Engineer of Record Company Name: JOAN SO ^) COPS k U LT I1U (o t"N61 Nag.5 ' p Mailing Address: 13.$0.-1(2. .VE NE (aa Dl'.I.Lt�V(.Jc WP+- 98004 - City State Zip Day Telephont4- 454 - 1 137 Fax Number: 42-s 2 1 �— t SEE s++E-FT Fo R. me' , iL c,. t 11 • » ..1.�4_ .....:::A ".' � w. ��siiicl :4..L.+Y�- ,��1,.!..:Pi.�:.'•i .:i �S.i :lY�' . . _ - . Existing Interior Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC I" Floor . . _ -- — .. 14 1 65To V _ N M 1 A3, F3, S3 2° Floor � r i -- 1 3m Floor::. .. — — — _. Floors .thru ._ B asement .. ,■ r . ■ • — Accessory Structure* _ — — . - . _. Attached,Garage — _, .--. _ Detached Garage ... _ — — Attached Carport _ -- .- — Detached Carport .— — _ Covered Deck I /6 50 V Uncovered Deck __ — _ — — — BUILDING PERMIT. INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 2 62 t 000 Existing Building Valuation: $ Scope of Work (please provide detailed information): A 14, 656 SF C 1 'V B 40 O S E' 3O l LtdWG (A)/ pp- Sfioe, S GPR'T'S STPAA) RANT 4 t ou M6 F M E % 'JZ o o MS, (■1€w PA-1 (N b (rd r. Will there be new rack storage? 0... Yes No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: I `14 Compact: S I Handicap: 6 Will there be a change in use? ❑...Yes. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: . Sprinklers ...Automatic Fire Alarm ❑...None Will there be storage or use of flammable, combustible or hazardous materials in the building? �(:. Yes ❑...No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities a Material Safety Data Sheets. 3 6 � ,g 5 poV G4Q.T5 l N c�T SRN 6 4r l•0N5 P C & T , 'N Fug UTILITY DISTRICTS: c a.e- IN 6 F< V N P Bt t (.D 1 • o Note: If the utility district-is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. )apptiationdpermit application (1.2003) 0.. Other (specify) Water City of Tukwila Water District 0.. Water District #125 ❑... Highline Water District 0... City of Renton Water District Sewer ;El.. City of Tukwila Sewer District ❑.. Val Vue Sewer District • ❑...City of Renton Sewer District ❑...City of Seattle Sewer District 0.. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) PUBLIC WORKS PERMIT. INFORMATION _ 206433 =0179 • Scope of Work (please provide detailed information): NOM POI U)(N6 * 1 t iP A (J (NS G EC, P `C6 for ( Flu-11 8, Qa a mem-iv vat) (.n l le'66\fe F(.t3c/) eZ.E11AT1 o N . 4 t N6 0.4IrT 2 �(R � -f 1D • Tle v t c C'rbj2A \ c T� (rvG iut )E LbNG Street Use: Street Use ❑...Channelization /Striping hrri2At Land Altering and /or Haug: '7 q �.. Land Altering: ..Cut . .t ( cubic yards Sto m Drainage: .. Storm Drainage Call before you Dig: 1- 800 - 424 -5555 Please refer to. Public Works Bulletin #1 for fees and estimate sheet. ❑...Flood Control Zone C. (5.^('I(G) O ver Information: f-''. City of Tukwila Sewer District 0.. Val Vue Sewer District ❑...City of Renton Sewer District ❑ .. City of Seattle Sewer District X . Sanitary Side Sewer OC 0.. Sewer Main Extension ❑ .. Private ❑ .. Public W ter Information: .. City of Tukwila Water District 0.. Water District #I25 0... Highline Water District 0... City of Renton Water District ❑ .. Water Main Extension ❑.. Private ❑...Public ❑ .. Water Meter/Exempt: Size(s): ❑ .. Deduct 0.. 1 Water Only I3/4. Water Meter Permanent #: Size(s):. POST (N to 1 t t - ra lae g S1:'D 0.. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons 0.. Fire Loop/Hydrant (main to vault) #: X ( Miscellaneous: I E S car N K t:.E R SO Monthly Service Billing to: Name: UNC! AN6E1D Mailing Address: tapplicationslpermit application (1.2003) Water ... 0 Sewer ... ❑ X .. Curb cut/Access /Sidewalk Size(s): • .. Fill 10, OoO cubic yards Hauling 0.. Landscaping Irrigation N Day Telephone: City State Sewage Treatment ❑ Fire Line ....0 Zip Water Meter Refund/Billing: Name: UNCIAA Day Telephone: Mailing Address: City State Zip Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment i 0 -3 HP /100,000 BTU Furnace >100K BTU _1._ Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan •— 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater I Ventilation System _ 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator - Comm/Ind MECHANICAL PERMIT INFOKMATION:- 206 431 =3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Use: Residential: Commercial: Fuel Type: Electric.... lapplicaiona■permir application (I -2007) 1/2007 1p BUILDING 0 VIR LO AUTHORIZED AGENT: Signature: ` - S( Print Name: P.. t C 911 L L� Mailing Address: 12424- - 42 0_ . 113P Page 4 City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** l //� Valuation of Project (contractor's bid price): $ ( , to5 `. Scope of Work (please provide detailed information): NEB coLF- Got. R$E CL•tJ etkoU S£ 4 5`t C N'T . 1 L,oQN 6E I -t 1 • New .... ❑ Replacement .... New ... Replacement .... ❑ Gas ...X Other: Indicate type of mechanical work being installed and the quantity below: SEE' S t 4-T M L O ( Fog- I NFL • RMIT?APPLICATION NOTES Applicable'to. "all permits' in this °application' . Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This fi gure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 2-14/0 3 Day Telephone: 206- 767- 2344 ' I / � (�-d City St ate Zip Date Application Accepted: y - 3 Date Application Expires: •=x.3 Staff Initials: 1 �._. ,. .. ....� ,.. .... .. «..a 1;..'w..i..��.eei.�:w.ti`_:'w n..t:v;.,. ,..: �i'' bzli:• itsktl«':'+ �;'. �f��fiti.&triC.p:+tgi' #ik►:�i�V: fc_;,s..... �.. City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003000049 Permit Number: M03 -019 Address: 13500 INTERURBAN AV S TUKW Status: APPROVED Suite No: Applied Date: 02/04/2003 Applicant: FOSTER GOLF LINKS Issue Date: Receipt No.: R03 -00766 Payment Amount: 475.31 Initials: SKS Payment Date: 06/25/2003 11:18 AM User ID: 1165 Balance: $0.00 Payee: PARK & RECREATION 411.00.594.760.41.19 TRANSACTION LIST: Type Method Description Payment Other ACCOUNT ITEM LIST: Description doc: Receipt MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Amount 475.31 Account Code Current Pmts 000/322.100 380.25 000/345.830 95.06 Total: 475.31 9912 06/25 9716 MTh h 0., 00 Printed: 06 -25 -2003 ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003000049 Permit Number: M03 -019 Address: 13500 INTERURBAN AV S TUKW Status: ISSUED Suite No: Applied Date: 02/04/2003 Applicant: FOSTER GOLF LINKS Issue Date: 06/25/2003 Receipt No.: R04 -00704 Payment Amount: 47.00 Initials: BLH Payment Date: 06/11/2004 12:38 PM User ID: ADMIN Balance: $0.00 Payee: BILL BOSTWICK - WPC TRANSACTION LIST: Type Method Description Amount Payment Cash BUILDING INVESTIGATION RECEIPT 47.00 Account Code Current Pmts 000/322.800 47.00 Total: 47.00 1730 06/11 9716 TOTAL 47.00 Printed: 06- 1.1. -20Q4 • Proje `� (/' ( Type of Inspection: ,..4 ).- e Address: Date Cal e ,4 Special Instructions: Date Wanted: b 'I Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)431 -3670 COMMENTS: Approved per applicable codes! 0 Corrections required prior to approval. J ;47. .R I NSPECTION(FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.,-Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: t / , � C70 Type of 1 s cti Wer ... is ■ / / / / / / /IC i r ..- ArOarigAllir-I-LeaW Special Instructions: Date Wa ted: i a.m. ` - - pap, 1--- (..7r" C.. e‘ J ( �� ice 6&'i .o. D e- 7- - 5 �-- !l e+� l lA �-(4/ . Project;. -- J t / , � C70 Type of 1 s cti Wer Address: r ..- Date Called: Special Instructions: Date Wa ted: i a.m. Requetteft Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 a Approved per applicable codes. INSPECTION RECORD Retain a copy with permit (206)431 -3670 Corrections required prior to approval. $47. EINSPECTIO ` FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: I I) R,e,"7")1.- e> .4 54 (Z•---5 1 C.ZD �- !' �i 4/`‘'27 /^� �i 1 .� I .tom f % 3 —o r..0- Al-e < r 50,•!24 � // r0 /4,4 ..1 4c v Requester: 174- /I 6, (1 -, q .c.- / h ,C4- 3 /7.7 q Gel cal7 4 ,'4-7 3 ,..--,k,.%.,' ,. n i Project: Type of Inspection: Ai Address: Date Called: Special Instructions: Date Wanted „Ai., i i__, / , cir-..„ Requester: Phone No: Date: / INSPECTION RECORD l Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. PERMIT (2 . 6)431 -3670 Corrections required prior to approval. nspector El $47.00 REINSPECTION F E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: iDate: z, Project: wis TYpf fstion:Q � AA r Date ailed: LP (A100 Special Instructions: 1 ..06 Date Wanted: c 17 Requester: Phone No: INSPECTIO INSPECTION RECORD Retain a copy with permit CITY 0 TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 121 Approved per applicable codes. Corrections required prior to approval. COMMENTS: fCC nspector: Date: 6, 0$47.00 NSPECTION F E REQUIRED. Prior to inspection, fee must be paid at 6300 SouthcentEy Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z z J 0 0 w CO W W 0 U- lu 0 g a 51 d I _ ZO W . 0 O N H W H H W Z LU 0 H O Z Pro C t � � i s � 4 � Type of I tion: r . Add e,ss: 0 CJ 1 l /7 �? t/( A Le,t Date Called: ♦S 6j 0 � Special Instructions. 0 Date Wanted: !fj (. (9 1 oy ft. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPE N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ''' COMMENTS: 1) "51 /eG t4...'ie SQL ft1 C/ ?.4 ' /, , G L9 4 . - t_ Approved per applicable codes. Corrections required prior to approval. El $47.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection. Receipt No.: Date: d z W Q Q 2 J U 0 O CO CO UJ U. WO � ' S = W H = Z � Zl W 0 co 0 I- W ~ O .. Z W U = O I z COMMENTS: ; /,4 640 C.1 r .(iU rg /'o 17 €9C, d air,(--71" . (7.i /-G /�[ 'z'- : —0 L.... 2--7 GIJe '6 Je ,e lo" `6 _e ✓LJ Z.-F' „ /- f7 ti? . •.4 2L e.4 e.,-•// '\ •.- - "" O c -- /o--e1 2) //,-)e)/1j - 447 .1-4 6:0!...r ."1 .4. , 54.,- I V c .5,..e..)--A-409 _ /3 d i 'itte- e _* - e .../ 't.Q Mit dis,er -. - .. a`m. m. `., Phone No: i i as 3 �- 77/f n i - Proj ct: Type of Inspection: In • Address: /y.s OC) 1.c1 i6,e,,eic'6A /LJ Date Called: .r /o--e1 Special Instructions: L'fJL(x , o...,�{ / � .. Requester Date Wanted: /3 d a`m. m. `., Phone No: i i as 3 �- 77/f r2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA'BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved.per applicable codes. Inspector: Corrections required prior to approval. • Date: 02 /7 3 El $47.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must'be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Projft: i Pr (0 0 /� Type of Insp ction; /?u) -/-%-/ r 2 Address: /3 r9e r . �.�J7 eZf2gb - Date Cal : 5 v� / Special Instructions: u Date Wanted: .5 3 — or a.m. P.m. Requester: Phone No: /1 LJ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit m05 0/r INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Corrections required prior to approval. COMMENTS: • PN" 2— m1°6 /All bi'7 -- " ',!, mS —.6f 4sFac I sp Date: ,._.. — i 3 - oy 7.00 REINSPECTIbN FEE REQUIR O. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Proje C / Type of pection: j S'� Ad • ress: / � _ 3 l I �l4 L "� (Ai bit -Ilf Date Ca led: + "� •SOS L(/ 0� l nstr Sp ual uctions: (T'r ( n e � : Date Wanted: / 6 4 a.m. Requester: we i Phone No: 2‹ aai '(a3te/ R Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • , , • x (2. 6) • 1 -3670 U Corrections required prior to approval. COMMENTS: PhA-se smnLe_ A 6aL) v2ESpvttni..42.6, Ins 'Date: $ .00 REINSPECTION E REQUIRED. for to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 1 . Call to schedule reinspection. Receipt No.: 'Date: q J Project: LL & • Typ,g of Inspection: { � C Adddddress: \ 3C0 0 Yf. vi4 4 Date Called. .5 , ( u / x Special Instructions: /� `� { 0,- 2 ', V 0 Date Wanted: � P �� Lt Requester: S 1-?.v - C' Phone No: '7,,t; < -- 2 ,)a) - ( S (O i Eil INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. p? PERM I . O. ( 06 431 -3670 .I..blCorrections required prior to approval. COMMENTS ivkmotvorteL1x, -- 70.s-dA L A-e \AAA 4.4= 7.00 REINSPECTION r id at 6300 Southcenter f Rec'ipt No.: REQUIRED. Prio to inspection, fee must be B ' d., Suite 100. C: II to schedule reinspection. Date: Proj ct: n� *-PA @1r L' Type of Inspection: t • -01.4 fri -&n ( sl, ,o . -., Address: Date Call d: ���f�f 1 Special Instructions: ate Wanted: /oq- 3I; C p.m. Requester: Phone No: ip INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMI CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) • -3670 n j QQproved per applicable codes. Corrections required prior to approval. COMMENTS: K. J7 A / /A h . 47.00 REINSPECTIOf4\FEE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: r .. 3 6, eff / 1 /- -, ' 7 len,Ahdruia--4- / i4-7 x ) t e-/ - – .....) eu A J - loppv-e4f/ , - 1 ter ,e/ouve cfr, -,-- ?e, /, .',v,- / 6 1 — ( A -, Al - ,,, 1 / b --_ - _ - ;re b4)-€. cz) Ali; i I ‘ c _? _,v14) r , , Vcnirat i 4 1 PP e6 ' 0, --- /° ‘'''`f< \ . , .... ..--/----7-", Special Instructions: _.., - t 1 Prpjecti - i (Y)51e-V 6-2f,Ltit. / • ,c Type f I spectiori: - I :-.. - i v i- i i or_r_;7:00 71.cie<1 . s Date Called: ij % -3 ///04 ..--/----7-", Special Instructions: _.., - t 1 '''i Date Wanted: . 3/2/ . Ll a.rn n i . Requester: ..- 7 4 PhonelsId,;) / - ctor: INSPECTION RECORD Retain a copy with permit INSPECTION N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 )431-3 70 roved per applicable codes. 0 Corrections required prior to approval. Date: 47.00 REINSPE ION FEE REQUIRE Prior to inspection, fee must be paid at 6300 SOuthcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: 6 I- 00 CO COW W I CO IL. w 0 g • < I • 11 Z l-0 Z 1- W. tu 2 D, D 0 SP-' X - r6 z 0 b COMMENTS: �f , e S`6�V�P ' ` e Cr, - �� I CS' 1-_, _ t' - 5 , a, 1--- cS�� -- 0/ /d c. \ /'� •- A c ' .J .�. LJ P'T 1 ti -2 , Co (se yY\ l'A tJ 1 vim.) CC1\ e-f 2 SUi y -P - r-C Special Instructions: ( Date Wanted: n. O 1 4 a.m. p.m. -C) v'— RequestPe_— ,nn trA, FJS Phone No:\ 53 1 —4 S S Pro 'ect: 1 C\tAb P T Inspection: P �... % p 1 - - � Address: \?1:� — N cru J kcy,c Date Called: iss1 2- ∎'7 — 0.- Special Instructions: ( Date Wanted: n. O 1 4 a.m. p.m. -C) v'— RequestPe_— ,nn trA, FJS Phone No:\ 53 1 —4 S S proved per applicable code ipt No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Date: nmo3 -o 1 9 PER orrections required prior to approval. 7.00 REINSPECTION FE REQUIRED. P or to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (20 • )431 -3670 Project: / 0 l Type of Inspection: Address: 1�S o r 1,.,.a i f , Date Called: �S �- )1 f 0 Special Instructions: Date Wanted: a f a.m. 1 t il !n P.m. Requeste[: 1 rv.„ // pi-ei -N S Pone No: ( .25 ' \ CA1 —L-) 5- INSPECTION RECORD Retain a copy with permit INSPE(iTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ® Corrections required prior to approval. COMMENTS: 53), t-t- tth i j P 1 I& &1T i( (MJ('P A I� s a A InA2ni rte 1m 4 a vro.37c " ec - 307.3 Utz Date: — I L I-09 47.00 REINSPE9!TION FEE REQUJRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., S ite 100. Call to schedule reinspection. Receipt No.: 'Date: .. .��.. � Project). `/ Type of Inspection: / � / Address: L' ,V & , 'tL- A.0 =! /:ae ' : ,� Date Called: C ' - O 4/ __ Special Instructions: Date Wanted ;. `' G -a z/ a.m. `P-m: Requester; . J(,y / � Phone No: _ INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 A0 roved per applicable codes. El Corrections required prior to approval. COMMENTS! si2c9virl n //o ❑ $47.O INSPECTION f E REQU RED. Prior to inspection, fee must be paid at 6300 Southcent r Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: �..il.'.•.�kL$1'x�_.... - ?s` '�Y+:;�''' � tYi�r:s' n.S wn�a.i`::! /'/i2 (206)431 -3670 S 'w4b lte + P - ^ e 1 (7, t " e Typ' O h spction: .� Address: (,Ln n -fe, 4-j, Da CCal . I c, D Special tructions: Date Wanted: a.m. Req uggte I f /II 464//-15 Phone No: C e-- "Lr (s3 - L? I -1, 7qq , INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER (206)431 -3670 IiJy,4pproved per applicable codes. 0 Corrections required prior to approval. ;�, C - i Li .1-2P L— i .! ft i! I v Psi — Date: ri $47.Od'R€INSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: !Date: Z =H '~ W re 2 00 to J H W W W g< _ I— III Z � W,W U I- W W I- W N U 0 z COMMENTS: CD Ps- k-- "f/v\ P S 1 e� t( - To rt KJS US U L n Address: - fJ pfd./ Date Called: J { c3i1 - 1 W L S_r s/SL(.1.4-t [, ' lsr- V P..� /aC' ) ,�..� 0 0,t ti3e, i n„1 Request, / /s Phone No: 1-2 �Le 5030 Pr ' ct: Type of Insp tion: Address: i Date Called: Special Instructions: Date Wanted: fr,c) f o Request, / /s Phone No: 1-2 �Le 5030 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 EL Approved per applicable codes. orrectio s requirea prior to approval. In Date: mot., I— 2-0 6t/ REINSPECTION FEE REQUIRED. Prior to fee must be • t 6300 Southcenter Blvd., Suite 100. Ca)1'to schedule reinspection. Receipt No.: 'Date: or Project Name FINALAPP.FRM City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Needs shift inspection Sprinklers: Fire Alarm: r' Hood & Duct: (.tV Halon: r /` Monitor: /, 4 7, Pre-Fire: Permits: TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM , ) J Permit No. /. /. ;? Steven M. Mullet, Mayor • �-- Address Suite #. f . ;, � 4:70 � /�! (, /'��(c �; , - Retain .current inspec.t.i.on_.schedule_— - � 1 Vfl - L.- ,' / -/c /) Approved without correction notice Approved with correction notice issued t 6) 5 /Z.. Wor/ Authorized - Signatue' Doe I Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206-575-4439 Projec,� ; / /E Type of I s ctiory Zi Address: Date Called: Special Instructions: Date Wanted/ o_ 4.../ a.m. Requester: Phone No: } INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. Date: 547.E EINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z H • W 6 —J U O 0 W p . W • 0 u j N d x Z � ZO W.W U 0 O N O 1- =W ▪ U U O Z US O f- Z CT CLOSEST FURNACE FLUE OUTLET, 4' -6" NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. ti SIDER + BYERS Fax:2062851045 1 2 Nickelson, Suite 300 I \ attics, WA 98109 T�I: 206.285 -2966 F x: 206 -185 -1045 T I�J: N: P OJECT: S BJECT: Dave Larson Dave Larson Foster Golf Links Clubhouse Fresh Air Intake MEMO FOR RECORD Apr 14 2004 7:22 e reviewed the locations of fresh air intake louver (LV -1) and fumace flue outlets on t e roof. It Looks like the distance between the flue outlet and the edge of the louver is i s 10ft and violates the UMC Section 403.2. V\ a recommend blocking the South half of the LV -1 and moving the intake duct to the Nartth half 4f the louver as shown on the attached sketch. With this revision the distance 4i weerj the intake louver and flue outlet will be increased to 11'-6" and exceed the Li MC rc.quimel 10' clearance. We balievOthe revised layout will meet the UMC and request approval. Pease let us know if you have any questions. BY: Goren attatoglu, P.E. 3 "f3l t PY.P}raS COPY TO: Job Site 206 267 -5033 RECEIVED APR 1 4 2004 D EPARTMENT P. 01 3 SIDER .BYERS I.1(_HuN IIAL LAQIM1LENS PAGE: 1 OF 2 DATE: 04 -14 -2004 PROJ. No.: 02027 December 10, 2003 City of Tukwila Department of Community Development Steve Lancaster, Director Mr. Mike Sweeney City Of Tukwila Foster Golf Course Projects 13500 Interurban Avenue South Tukwila, WA 98168 RE: Request for Extension — Permit No. M03 - 019 — Foster Golf Clubhouse Dear Mike: If you should have any questions, please contact our office at (206) 431 -3670. Robert Benedicto Building Official /sks File: Permit No. M03 -019 Steven M. Mullet, Mayor This letter is in response to your written request for an extension to Permit No. M03 -019. Based on the information received, the City of Tukwila Building Division will be extending you permit to June 9, 2004. Please be advised that this will be the only extension granted for this project and no further notice will be given prior to the expiration date. A new permit and associated fees will be required after the above -noted expiration date. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206. 431 - 3665 w . re 2 • J U 0 V) O W = J CO w 0 rn . = d: I- al Z � 1-0 Z uj D � O D- 01--- W ku H H . u. O Z 1" 0 Z . Stefanla Spencer : DCD Permit Extensi "n Request - M03 -019 Foster Golf Clubhouse From: Mike Sweeney To: Spencer, Stefania Date: 12/09/2003 11:30AM Subject: DCD Permit Extension Request - M03 -019 Foster Golf Clubhouse Stefania: Rick Still forwarded to me the DCD letter of November 4 under your signature, advising that without commencement of work under Permit #M03 -019 it would expire on 12/22/03. This permit relates to the clubhouse project and restaurant heating, refrigeration, and other mechanical equipment. The clubhouse project is at its 39% completion benchmark -- sitework grading and utilities, a large parking lot, foundation and slabwork, wall framing is completed. Presently truss placements, roofing, sheathing, mechanical and electrical rough -in are in progress, the building is nearing being "closed in ". The mechanical equipment installations inspections required under permit M03 -019 have yet to occur, are still needed, that work likely to commence in February '04 (as the owner's rep I of course preferring it might happen earlier!). This document formally requests the full 180 -day permit extension allowed which would carry the permit active until June 22, 2004. The project's current contract time completion date is 5/21/04. The justification you require I am hopeful is explained by the fact that the project did not bid nor was fully permitted in its intended timeframe, and the award of contract by council was delayed by the unanticipated time required in rejection of an apparent low- bidder. Please advise me of the outcome of this request; thank you in advance for your consideration . Mike Sweeney, Owner's Representative City of Tukwila Foster Golf Course Projects Office: 13900 Interurban Ave. South Site: 13500 Interurban Ave. South Tukwila, WA 98168 msweeney @ci.tukwila.wa.us Desk: 206/267 -1685 Fax: 206/439 -8453 Pagel December 1, 2003 Mike Sweeney Owner's Representative PROJECT: Foster Golf Links Clubhouse Tukwila, WA SUBJECT: Revisions in the Mechanical Room Dear Mike: We revised our design and changed the 599 MBH gas input water heater in to a 399 MBH gas input water heater and a storage tank assembly. These revisions are sent to the contractor on 9 -23 -2003. Note that with these revisions all the gas equipment in the Mechanical Room 113 will have a gas input less than or equal to 399 MBH. Please let us know if you have any questions. Sincerely, SIDER & BYERS ASSOCIATES, INC. Nathan Byers, P.E. SIDER+BYERS'Associates, Inc 192 Nickerson, Suite #300_ r &l w SI DER + BYERS MECHANICAL ENGINEERS c5 at ; r; ;, EXPIF„ S M'3 f:ITY OF T )K A DEC 1 1 2003 PERMIT CEN fER Seattle, Washington 98109 Phone: 206.285.2966 Fax: 206.285.1045 z re 2 W 00 • w 0: wz J F. CO u_ • w o LL Q I w. o Z �. U0 off'; o . w w �- — O ; Z ; U D: 0 z November 4, 2003 Rick Still 12424 42nd Avenue South Tukwila, WA 98168 RE: Permit Application No. M03 -019 13500 Interurban Avenue South Dear Permit Holder: City of Tukwila Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to December 22, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. M03 -019 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431.3670 • Fax: 206 - 431 -3665 Mike Sweeney -Mech Permit resubmittal "^r3- 19-03,doc Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: March 19, 2003 City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Response to Incomplete Letter # Response to Correction Letter # 1 Revision # after Permit is Issued REVISION SUBMITTAL Plan Check/Permit Number: M03-019 Project Name: FOSTER GOLF LINKS — CLUBHOUSE Project Address: 13500 Interurban Avenue S Contact Person: Rick Still /Bruce Fletcher Phone Number: 206 -767 -2344 Summary of Revision: Please see attached memo requesting clarification on the design. Sheet Number(s): none "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: S'/�-- Entered in Permits Plus on � CORRECTION RECEIVED CITY OF TUKWILA MAR 1 9 2003 PERMIT CENTER M op, -o19 Page 1 eene - Memo -Mech • ermit comm' ' s from SB 031903.doc SIDER+ BYERS (dE ( HAW( Al E N61NE E AS Seattle, WA 98109 180 Nickerson, Suite 304 Tel: 206 -285 -2966 Fax: 206 -285 -1045 MEMO FOR RECORD TO: David A. Clark Architects PAGE: 1 OF 1 ATTN: David Clark DATE: 03 -19 -03 PROJECT: Foster Golf Links Clubhouse PROJ. No.: 02027 SUBJECT: Tukwila Mechanical Permit Comments, M03 -019 We reviewed the enclosed Tukwila mechanical permit comments. Following is our response. 1. Pressure Control in Kitchen and Meeting Rooms: Kitchen: Kitchen has a gas make up air unit and two Type -I exhaust fans. Make up air unit provides 7,120 cfm and exhaust fans exhaust 7,900 cfm air. Fans and make up air unit are interlocked to run at the same time and keep the kitchen under negative pressure. The remaining 780 cfm air will be transferred from lounge. Relief grilles in kitchen ceiling will serve to relieve lounge air when the lounge systems deliver more than 780 cfm outside air in response to CO2 sensor. Relief grilles will have back draft dampers to prevent reverse airflow when the systems are not running. The doors between lounge and kitchen will have sufficient free area to allow air freely flow from lounge to kitchen. Meeting Rooms: Meeting rooms will operate with varying outside air supply in response to CO2 sensors. Air will be relieved from relief duct above ceiling. Counter balanced back draft dampers will prevent reverse airflow when systems are not running. 2. Parking Garage HVAC Duct: Parking garage grille and ductwork is for make up air from outside. It has no connection to building HVAC systems. It is connected to an exterior louver and designed to provide outside air when the exhaust fan is running. Please let me know if you have any questions. BY: Goren Hattatoglu, P.E. CORRECTION ('1O3Oi'J March 13, 2003 Mr. Rick Still Parks & Recreation Administration 12424 42 " Avenue South Tukwila, WA 98168 RE: CORRECTION LETTER #1 Development Permit Application Number M03 -019 Foster Golf Links —13500 Interurban Avenue South Dear Rick: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Planning, Fire and Public Works Departments have no comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, Stefania Spencer Permit Technician encl xc: File No. M03 -019 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 1 - ' RMIT COORD Copy PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M03 -019 DATE: 03 -20 -03 PROJECT NAME: FOSTER GOLF LINKS - CLUBHOUSE SITE ADDRESS: 13500 INTERURBAN AV S Response to Incomplete Letter # X Response to Correction Letter #1 Revision # After Permit Is Issued Original Plan Submittal DEPA TMENTS: n G 1- -1I 'OJ ❑ 7 Build Nivi i Public Works TUES /THURS ROUTING: Please Route Documents /routing slIp.doc 2 -28.02 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03 -25 -03 Complete E Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg El Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: p'ERMIT COORD COPY ❑ Planning Division C ❑ Permit Coordinator Af Not Applicable ❑ 0 DUE DATE: 04 -22 -03 DATE: DEPARTMENTS: Building Division Public Works ❑ PLA SLIP ACTIVITY NUMBER: M03 -019 PROJECT NAME: FOSTER GOLF LINKS - CLUBHOUSE SITE ADDRESS: 13500 INTERURBAN AVENUE SOUTH DATE: 02 -04 -03 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete d Incomplete Comments: 510 A x- 2 ZS-th Fire Prevention Structural ❑ Planning Division Permit Coordinator DUE DATE: 02-06 -03 0 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO9TING: Please Route ,, Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: Documentshouting slip.doc 2.28 -02 PERMIT COORD Copy DUE DATE: 03 -06-03 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: :: isit�:, w;.: �.: L.:: v.,::. �c.. V::::..:;.:,+. m: �.» �:,:;: Si: a'..:: a�.., nr.. a.. �.: �:. u: �. �3. ..:+.:::;,,..•.liu:.u:::. ,e F(25-052-00U (8197) F625-052-000 8l97) DEPARTMENT OF LABOR AND INDUSTRIES - r - Detach And Display Certificate REGISTERED AS PROVIDED BY LAW AS CONST. „CONT. GENERAL ;• PCT.:.9 12 / 2 0 04 EFFECTIVE •••• • :12/27/2002 '• WADE PERROW CONSTRUCTION LLC PO BOX. 1728 GIG HARBOR WA 98335 Detach And Display Certificate REGISTERED AS PROVIDED BY LAW AS CONS T. CONT GENERAL REGI ST . # EXP . DATE CCO1 WADEPCL982R7 12/27/2004 EFFECTIVE DATE 12/27/2002 WADE PERROW- CONSTRUCTION LLC PO BOX 1728 GIG HARBOR WA 98335 Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES - - 1 Please Remove And Sign Identification Card Before Placing In Billfold ,f_ z 6 D C.) 00 ijj • W J F— . CO IL • uj 0 • g:i Q . ! a • I- 11 Z I -0 Z '- taw . 0 D u jz 0 w 0 SC OPE O F W O R K 1 INCLUDED: 1. SMITH & GREENE COMPANY (S&G) SHALL UNCRAiE AND SET N PLACE ALL SPECIFIED FOOD SERVICE INCLUDED: 1. SMITH & GREENE COMPANY (S&G) SHALL UNCRATE AND SET IN PLACE ALL SPECIFIED FOOD SERVICE EQUIPMENT SUPPLIED BY U5. 2. S&G SHALL INSTALL ALL SPECIFIED CUSTOM MADE SHEET METAL ITEMS, SUCH AS EXHAUST HOODS, DISHTABLES, AND SERVICE COUNTERS, AND FASTEN TO FLOOR, WALL OR CEILING, AS REQUIRED, READY FOR CONNECTION TO UTILITIES. 3. S&G SHALL RUN REFRIGERATION LINES AND CONDENSATE LINES. 4. S&G SHALL REMOVE ALL DEBRIS RELATED TO THE INSTALLATION OF THE FOOD EQUIPMENT. EXCLUSIONS: 1. ANY PLUMBING, ELECTRICAL, OR MECHANICAL LABOR, MATERIALS OR PERMITS, INCLUDING ANY INTERCONNECTIONS OR FINAL CONNECTIONS TO UTILITIES. 2. ANY HARDWARE TO CONNECT TO UTILITIES, I.E. PRESSURE VALVES, PIPING, WIRING, SWITCHES, MAG STARTERS, DUCTING, OR GREASE TRAPS. 3. ANY CUTTING, PATCHING, PAINTING, CORE DRILLING, SEISMIC WORK, WALL BACKING, HOISTING, OR OFF -SITE DEBRIS REMOVAL. GENERAL TERMS EQUIPMENT DELIVERY: OWNERS / CONTRACTORS SHALL PROVIDE INSURED SAFE STORAGE FOR ITEMS AS THEY ARRIVE THROUGH FINAL INSTALLATION, MAKE VISUAL EXTERIOR INSPECTIONS OF FREIGHT AS IT ARRIVES, IMMEDIATELY NOTE ANY DAMAGE TO THE SHIPPER ON THE BILL OF LADING, AND PROMPTLY ADVISE SMITH & GREENE CO. EQUIPMENT DELIVERY MUST BE WITH IN SIX MONTHS OF THIS PROPOSAL. JOBSITE CONDITIONS: OWNER / CONTRACTOR SHALL MAKE AREA READY FOR DELIVERY OF OR EQUIPMENT, INCLUDING PAVES ACCESS, CLEAN, SECURE WORK AREA WITH FINISHED FLOORS, WALLS AND CEILINGS, AND SHALL ALSO PROVIDE FINAL WIPE -DOWN AND CLEAN UP. WARRANTY: IT SHALL BE AGREED THAT ALL WARRANTIES START UPON SUBSTANTIAL COMPLETION OR USE OF EQUIPMENT, WHICHEVER I5 FIRST. NOTE: ALL MATERIAL IS GUARANTEED TO BE AS SPECIFIED. ALL WORK I5 TO BE COMPLETED IN A MANNER ACCORDING TO STANDARD PRACTICES. ANY ALTERATION OR DEVIATION FROM ABOVE SPECIFICATIONS INVOLVING EXTRA COSTS WILL BE EXECUTED ONLY UPON WRITTEN ORDERS, AND WILL BECOME AN EXTRA CHARGE OVER AND ABOVE THIS PROPOSAL. ALL AGREEMENTS ARE CONTINGENT UPON STRIKES, ACCIDENTS OR DELAYS BEYOND OUR CONTROL. OWNER IS TO CARRY FIRE, NATURAL DISASTERS AND OTHER NECESSARY INSURANCE. OUR WORKERS ARE FULLY COVERED BY WORKMAN'S COMPENSATION INSURANCE. GENERAL NOTES 1. The service requirements shown on these plans are for food service equipment specified by Smith & Greene Company, Herein after know as Food Service Contractor "FSC•' These plans are prepared and furnish for the purpose of indicating equipment service requirements and rough -in spotting locations only and do not relieve the General Contractor. Sub - Contractors, or other involved trades of the responsibility of the above parties to consult with the architect, owner or his representative concerning all other requirements of the building. 2. All miscellaneous parts and items including grease traps, grease interceptors, faucets, valves, traps, trim, wiring, magnetic starter, disconnects, electrical panels, thermal overload protection, cords, and plugs, etc. are supplied by the appropriate sub - contractor unless otherwise specified on these plans of by separate written contract. 3. Plumbing, electrical, and refrigeration rough -in and final connections and hook -up shall be provided and performed by the respective sub- contractors in compliance with applicable national, state, and local codes. All rough -ins are subject to change and verification pending the final selection and location of all equipment. 4. The General Contractor shall provide and install the proper backing for wall and ceiling mounted equipment, shelving, brackets, braces, table cantilever bases, stool cantilever brackets, etc. As required and indicated on the Smith & Greene Company plans specifications and equipment brochures. 5. All items noted "existing, future, by other, and NIC (not in contract)" shall be verified by the respective sub- contractor for size and requirements prior to rough -in and final connection. 6. Not Used 7. The General Contractor shall provide floor, wall, ceiling, and roof penetrations, fire -rated shaft(s) for exhaust ducting, shaft(s) for make -up air ducting PVC and sleeves for refrigeration, syrup, inert gases, beer and wine line(s) to accommodated the requirements and proper installation of all food service equipment. 8. It shall be the responsibility of the General Contractor to provide weather protection for all roof, floor and wall penetration. prior to and during the installation of the food service dealer's equipment and furnishings. 9. It shall be the responsibility of the General Contractor to properly seal all flax, roof and wall penetration. a. required after the installation of the food service dealer's equipment and furnishings. 10. It shall be the responsbIlity of the General Contractor to notify Smith & Greene Company of any corrections, comments, or revisions on the plan set se approved for building permit, immediately upon receipt of said plans and permit, prior to site construction. All dimensions shown on these plans are measured from finished wars, floor. ceiling, and/or centerlines of utAity rough -ins. The subcontractors shall make necessary allowance. for finishes Adoring rough -in a. required. DOOR BY G.C. 1.1 �i�i IIIIIII1111� - IIII1111 IIIIIIIIIIIII,I� III III Illt II'.... 11111111 111111111111111 ■E 711111111•11 C �TJ C cJ r.7111 EA ILA ICS E7 NUM M7 © IC11 177 ►�lil N �! �..�.. wourrow ! OA Ai; fie � -w. ow RIM now ges r • SERVICE COUNTER SEE "A" DRAWINGS BAR CASEWORK SEE "A" DRAWINGS SERVICE STAT10N SEE "A" DRAWINGS EQUIPME/YT PLA/1 t).3 -0/ • DOOR BY G.C. • r c too r X t��Q • t t os' o ' • ft Cr. 9 044 s ikr. SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL EitLECTRICAL LUMBING rpg PIPING CITY OF TUKWILA BUILDING DIVISION SMOKER COVER BY G.C. •---- SMOKER PAD BY G.C. EQUIPMENT _PAD BY G.C. DOOR BY G.G. 1 • A 03 N 0 1 17.1 ,Qtr te_ QS 0 Ea � Dr) -- (5 0 u_ aa • i Q -101 - KITCHEN PLAN Q -102 - SCHEDULES Q -103 - ELECTRICAL Q -104 - PLUMING Q -201 - ELEVATIONS Q -202 - ELEVATIONS Q -501 - HOOD DRAW Q-504 -HOOD DRAWINGS Sc. • 1/4 : 1' - Oak 12/13/02 UR RIP 4* 3-01? I I i 1 24 1 TILT SKILLET 25 1 - KETTLE. STEAM JACKETED 25.1 1 KETTLE a POT 25.2 , FILLER. 1 'STAND, KETTLE 26 1 RANGE. HEAVY DUTY, GAS 27 1 WEN. CONVECTION, GAS 28 1 SPARE NUMBER 28 3 KITCHEN SWIG DOOR 29 2 SINK. HAND _ 30 1 MAIJS'T HOOD 30.1 1 ECIMUAST HOOD FAN 31 1 FIRE SUPRESSION - PREP LNE 32 1 CART. BANQUET SERVICE 32 1 CJRT. BANQUET SERVICE 33 1 SLICER. F000 _ 34 1 TABLE, WORK 35 1 SOIL PREP 35.1 1 . FAUCET. WALL MOUNT 36 1 LT SHELVING. WIRE 37 1 SOL DISH TABLE 36 1 'CLEAN DISH TABLE 39 1 WAR R. RACK CONVEYOR 40 1 PRE-RINSE. WALL MOUNT 41 1 'MATER HEATER. BOOSTER 42 1 LT SHELVNNG. ME 43 1 DUCT H000 (D/W) 44 2 FAUCET. WAIL MOUNT 45 1 3 COMPARMENT SNK 46 1 SINK. MOP 47 1 SHELVING, MIRE, DRY STORAGE 48 - SPARE NUMBER 49 1 CO2 TANK 50 1 SHELVNG. MARE. LOCKED UO. STOiR. 51 1 SINK. DROP -IN S2 1 \ TRASH CAN 53 1 - REFRIGERATOR. UNOEIOOUNTER. COMPACT 54 55 56 57 58 59 61 62 63 64 65 66 67 69 P g ti 4 N f 1 70 71 72 73 74 75 76 77 78 79 80 81 81.1 81.2 82 83 1 REFRIGERATOR. SANOMACH/SALAD PREP 84 1 TABLE. HOT FOOD 85 1GERATOR, PREP 86 1 • i MIC OWAVE 87 1 SHELF. MICROWAVE 88 1 • 3 SLOW COOK/HOLD 89 1 - STATION 90 1 SHELVING. MARE 91 2 WARMER, FOOD OVERHEAD 92 1 DEL PASS SHELF 93 1 ABLE. WORK 94 1 EXHAUST HOOD (COMMIE) 94.1 1 E OMUST H000 (COOKLJE) 95 1 FIRE SUPRESSION - COOKUNE 95.1 1 E3 W»ST HOOD FAN 95.2 , 1 MAKEUP MR SYSTEM 96 1 RANGE. HEAVY DUTY. SPREADER. GAS 97 1 OPEN BURNERS/REFRIGERATED RAIL. COMBO 98 1 REFRIGERATOR. SHORTY 99 - 1 SALAMANDER BROILER. GAS 100 1 RANGE. GRIDDLE, GAS 101 1 • a - BROILER, GAS 102 1 REFRIGERATOR. SHORTY 103 1 RANGE. BROILER. GAS 104 I REFRIGERATOR. SHORTY 104.1 1 REMOTE REFRIGERATION 105 1 FRYER. DUMP STATION 106 , 1 FRYER, DEEP FAT. GAS 107 1 ABLE, WORK 106 1 CASTER CONVEYOR 109 - LT • • . a GUARDS a WALL CAPS 110.1 1 WIN COOKUNE WILL PAD ' 110.2 1 ' 3 ' COOKLNNE WALL PAD BOO 1 WNDERIWIR MO0M.IR#t MAR DI: 901 1 . RUMIBER 902 1 UN0E19111 GLASS RACK 903 ,, 2 ' a • - COMB. ICE MN 9O4 1 UNMOOR FILLERS t aMwISaMRDS Figi 905 2 .1 - BLENDER STATION 606 2 • /CFB.LER. OUISS/MUD_PIAPIEB Q 4 A 907 1 .... DRY WASTE 907 1 ' i ORY WASTE Rlrr c, 909 2 .. CUSS RICK 910 1 i a SNNI( 9 11 ` 1 ' a FILERS a _RNN IO IROS 912 1 • MAR COOLER , 912.1 1 a ' REFRIGERATOR 913 1 • Art COOLER 914 1 , a IMMIX TONER 915 1 . s- • ER UIPRIE rT ` 916 1 ,T1 1 . • 'MOWN (PREP) n 2 I • • MOWN OM 1111101.) Po 1 .. 4 4 SC OPE O F W O R K 1 INCLUDED: 1. SMITH & GREENE COMPANY (S&G) SHALL UNCRAiE AND SET N PLACE ALL SPECIFIED FOOD SERVICE INCLUDED: 1. SMITH & GREENE COMPANY (S&G) SHALL UNCRATE AND SET IN PLACE ALL SPECIFIED FOOD SERVICE EQUIPMENT SUPPLIED BY U5. 2. S&G SHALL INSTALL ALL SPECIFIED CUSTOM MADE SHEET METAL ITEMS, SUCH AS EXHAUST HOODS, DISHTABLES, AND SERVICE COUNTERS, AND FASTEN TO FLOOR, WALL OR CEILING, AS REQUIRED, READY FOR CONNECTION TO UTILITIES. 3. S&G SHALL RUN REFRIGERATION LINES AND CONDENSATE LINES. 4. S&G SHALL REMOVE ALL DEBRIS RELATED TO THE INSTALLATION OF THE FOOD EQUIPMENT. EXCLUSIONS: 1. ANY PLUMBING, ELECTRICAL, OR MECHANICAL LABOR, MATERIALS OR PERMITS, INCLUDING ANY INTERCONNECTIONS OR FINAL CONNECTIONS TO UTILITIES. 2. ANY HARDWARE TO CONNECT TO UTILITIES, I.E. PRESSURE VALVES, PIPING, WIRING, SWITCHES, MAG STARTERS, DUCTING, OR GREASE TRAPS. 3. ANY CUTTING, PATCHING, PAINTING, CORE DRILLING, SEISMIC WORK, WALL BACKING, HOISTING, OR OFF -SITE DEBRIS REMOVAL. GENERAL TERMS EQUIPMENT DELIVERY: OWNERS / CONTRACTORS SHALL PROVIDE INSURED SAFE STORAGE FOR ITEMS AS THEY ARRIVE THROUGH FINAL INSTALLATION, MAKE VISUAL EXTERIOR INSPECTIONS OF FREIGHT AS IT ARRIVES, IMMEDIATELY NOTE ANY DAMAGE TO THE SHIPPER ON THE BILL OF LADING, AND PROMPTLY ADVISE SMITH & GREENE CO. EQUIPMENT DELIVERY MUST BE WITH IN SIX MONTHS OF THIS PROPOSAL. JOBSITE CONDITIONS: OWNER / CONTRACTOR SHALL MAKE AREA READY FOR DELIVERY OF OR EQUIPMENT, INCLUDING PAVES ACCESS, CLEAN, SECURE WORK AREA WITH FINISHED FLOORS, WALLS AND CEILINGS, AND SHALL ALSO PROVIDE FINAL WIPE -DOWN AND CLEAN UP. WARRANTY: IT SHALL BE AGREED THAT ALL WARRANTIES START UPON SUBSTANTIAL COMPLETION OR USE OF EQUIPMENT, WHICHEVER I5 FIRST. NOTE: ALL MATERIAL IS GUARANTEED TO BE AS SPECIFIED. ALL WORK I5 TO BE COMPLETED IN A MANNER ACCORDING TO STANDARD PRACTICES. ANY ALTERATION OR DEVIATION FROM ABOVE SPECIFICATIONS INVOLVING EXTRA COSTS WILL BE EXECUTED ONLY UPON WRITTEN ORDERS, AND WILL BECOME AN EXTRA CHARGE OVER AND ABOVE THIS PROPOSAL. ALL AGREEMENTS ARE CONTINGENT UPON STRIKES, ACCIDENTS OR DELAYS BEYOND OUR CONTROL. OWNER IS TO CARRY FIRE, NATURAL DISASTERS AND OTHER NECESSARY INSURANCE. OUR WORKERS ARE FULLY COVERED BY WORKMAN'S COMPENSATION INSURANCE. GENERAL NOTES 1. The service requirements shown on these plans are for food service equipment specified by Smith & Greene Company, Herein after know as Food Service Contractor "FSC•' These plans are prepared and furnish for the purpose of indicating equipment service requirements and rough -in spotting locations only and do not relieve the General Contractor. Sub - Contractors, or other involved trades of the responsibility of the above parties to consult with the architect, owner or his representative concerning all other requirements of the building. 2. All miscellaneous parts and items including grease traps, grease interceptors, faucets, valves, traps, trim, wiring, magnetic starter, disconnects, electrical panels, thermal overload protection, cords, and plugs, etc. are supplied by the appropriate sub - contractor unless otherwise specified on these plans of by separate written contract. 3. Plumbing, electrical, and refrigeration rough -in and final connections and hook -up shall be provided and performed by the respective sub- contractors in compliance with applicable national, state, and local codes. All rough -ins are subject to change and verification pending the final selection and location of all equipment. 4. The General Contractor shall provide and install the proper backing for wall and ceiling mounted equipment, shelving, brackets, braces, table cantilever bases, stool cantilever brackets, etc. As required and indicated on the Smith & Greene Company plans specifications and equipment brochures. 5. All items noted "existing, future, by other, and NIC (not in contract)" shall be verified by the respective sub- contractor for size and requirements prior to rough -in and final connection. 6. Not Used 7. The General Contractor shall provide floor, wall, ceiling, and roof penetrations, fire -rated shaft(s) for exhaust ducting, shaft(s) for make -up air ducting PVC and sleeves for refrigeration, syrup, inert gases, beer and wine line(s) to accommodated the requirements and proper installation of all food service equipment. 8. It shall be the responsibility of the General Contractor to provide weather protection for all roof, floor and wall penetration. prior to and during the installation of the food service dealer's equipment and furnishings. 9. It shall be the responsibility of the General Contractor to properly seal all flax, roof and wall penetration. a. required after the installation of the food service dealer's equipment and furnishings. 10. It shall be the responsbIlity of the General Contractor to notify Smith & Greene Company of any corrections, comments, or revisions on the plan set se approved for building permit, immediately upon receipt of said plans and permit, prior to site construction. All dimensions shown on these plans are measured from finished wars, floor. ceiling, and/or centerlines of utAity rough -ins. The subcontractors shall make necessary allowance. for finishes Adoring rough -in a. required. DOOR BY G.C. 1.1 �i�i IIIIIII1111� - IIII1111 IIIIIIIIIIIII,I� III III Illt II'.... 11111111 111111111111111 ■E 711111111•11 C �TJ C cJ r.7111 EA ILA ICS E7 NUM M7 © IC11 177 ►�lil N �! �..�.. wourrow ! OA Ai; fie � -w. ow RIM now ges r • SERVICE COUNTER SEE "A" DRAWINGS BAR CASEWORK SEE "A" DRAWINGS SERVICE STAT10N SEE "A" DRAWINGS EQUIPME/YT PLA/1 t).3 -0/ • DOOR BY G.C. • r c too r X t��Q • t t os' o ' • ft Cr. 9 044 s ikr. SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL EitLECTRICAL LUMBING rpg PIPING CITY OF TUKWILA BUILDING DIVISION SMOKER COVER BY G.C. •---- SMOKER PAD BY G.C. EQUIPMENT _PAD BY G.C. DOOR BY G.G. 1 • A 03 N 0 1 17.1 ,Qtr te_ QS 0 Ea � Dr) -- (5 0 u_ aa • i Q -101 - KITCHEN PLAN Q -102 - SCHEDULES Q -103 - ELECTRICAL Q -104 - PLUMING Q -201 - ELEVATIONS Q -202 - ELEVATIONS Q -501 - HOOD DRAW Q-504 -HOOD DRAWINGS Sc. • 1/4 : 1' - Oak 12/13/02 UR RIP 4* 3-01? I I ITEM NO 1 2 2.1 3 QTY 1 1 1 1 L Q U I H M L N T 5 C H L D U L L EQUIPMENT CATEGORY EQUIPMENT MANUFACTURER MODEL NUMBER REMARKS 0 O o. WW J 48 F N z 0 U Lit Z o 0 0 d. 2 < 3 �c Cl- z r ; J > 0 Lii V i W 4c 8 _ a . -. OCZ V � W y e ` ELECTRICAL REMARKS cr < Z 3 r- • 58 � W p N 00 ix < 3Z O 0 F Z <_ F-W N � v>' F- < F-= o = c ° � Z 3 ' Z WW ^' oin z Z W o< z Z g gZ aW Z z r-. �WC' z _ Z W do D Z L it W N I Vf dU REMARKS © > W i a2 v > W i C ; can > W ii- }� e� ? W ezt') AC V o ti, , 15 ? M X }C W W Q �3 c 15 I BI �, REMARKS NO WALK -IN COOLER /FREEZER KYSOR CUSTOM S&G S&G EC 20.0 120 1 60 X M 104 UGHTS & CONTROLS -.--- . -- ' 1 EVAPORATOR COIL, COOLER ERICKSON REFRIGERATION TBD S&G S&G EC & S&G 5.0 -- 120 1 60 X 80 - . 3/4 60 -- AIR -GAP TO FS I -_- - 2 COMPRESSOR, COOLER BY ERICKSON REFRIGERATION TBD COMBINED W/ 812.1 S&G S&G EC & PC 15.0 - En 208 © 60 01 _ OUNIT DON'T DUPLICATE - - I 2.1 COOLER SHELVING METRO ONE LOT SdcG SdcG -- .-_- - ��- - I --- • 3 4 5.1 5.2 2 1 1 RACK, UTIUTY INTERMETRO INDUSTRIES RE1 S&G S&G - ----- -- .-�_ I 4 RACK, DUNNAGE INTERMETRO INDUSTRIES 2KR346MC S&G S&G S&G S&G S&G - - EC MI 20.0 MM. __ 120 1 60 X ■_ 104 UGHTS do CONTROLS --_--_- . IIIII _- _- I I I _-- _-_ --_ -__ --- --- 5.1 6 RACK, DUNNAGE INTERMETRO INDUSTRIES 2KR366MC 6 1 1 WALK -IN FREEZER KYSOR CUSTOM EVAPORATOR COIL. FREEZER ERICKSON REFRIGERATION TBD S&G y� EC & S&G EC & S&G 8.0 25.0 _ - _ ZIE 208 208 1 3 60 60 X X . 80 HEAT TAPE DRAJN VERIFY _ _---- - _ - - -- 3/4 60 _ -- - AIR -GAP TO FS I ' - --- - MI1111111111111111111111 -- --_ - 7.1 7.2 1 COMPRESSOR. FREEZER BY ERICKSON REFRIGERATION TBD SdcG S&G 8 1 FREEZER SHELVING METRO ONE LOT S&G S&G - --- .... ---.- . -- I -MI ___ 8 9 2 RACK. UTIUTY INTERMETRO INDUSTRIES RE1 S&G S&G - ••• I __- -__ 9 10 1 SMOKER J&R 700 SdcG S&G S&G S&G EC - - - 8.0 8.2 1/2 120 115 1 1 60 60 X X 5 -15P 12 48 . I VERIFY 1 10 10.1 11 12 13 10.1 1 SPARE NUMBER 11 1 RACK LOCKWOOD CR69 -7 12 1 RACK. MOBILE INTERMETRO INDUSTRIES RE1 Sd&G SdcG 13 1 MIXER. COUNTER HOBART US FOODSERVICE A200 +BUILDUP MIXER STAND SdcG S&G 13.1 14 1 1 STAND, MIXER ADVANCE TABCO MT -GL -242 S&G S&G - --- ■- --_-- _- I -- --- 13.1 TABLE, WORK ADVANCE TABCO KAG -306 SdcG S&G - I -- --- 14 15 1 SHELVING, WIRE INTERMETRO INDUSTRIES 1436BR S&G S&G - VERIFY 15 16 1 BIN, INGREDIENT RUBBERMAID 3600 S&G SdcG - 16 17 18 1 TABLE, WORK ADVANCE TABCO KAG -303 NO SHELF S&G S&G - 17 SHELVING, WIRE INTERMETRO INDUSTRIES 1436BR S&G S&G - 18 19 1 REFRIGERATOR, REACH -IN TRUE FOOD SERVICE T -49 S&G S&G - 9.0 1/2 120 60 5 -15P 12 W/ CORDSET 19 20 1 EMPLOYEE COUNTER MILLWORK CUSTOM P -LAM GC GC - I 20 21 1 EMPLOYEE LOCKERS MILLWORK CUSTOM 12X12 GC S&G GC SdcG - - ____.- -- --- -- I I --- -- _-_ 21 22 22 1 TABLE. WORK ADVANCE TABCO KAG -304 23 1 OVEN. SLOW COOK /HOLD ALTO -SHWA 1000- TH -1 /HD S&G SdcG MEM 28.8 6.0 208 1 60 X ■- 73 208 -240V --_--_- alli -- I IN --- 23 24 1 TILT SKILLET GROEN HFP /2 -4.NAT S&G SdcG EC & PC 5.0 -- 120 1 60 X ■- 30 _----_. IIIIIIMI -■ ®® 26.5 4.5'W.C. MIN.,14.5" MAX ' ----_w-- - 24 25 1 KETTLE, STEAM JACKETED GROEN TDB /C -40 S&G SdcG EC - PC 30.0 10.8 208 © 60 X ■ _ UM _ MI - �- ' - - _ 25 25.1 25.2 1 1 FILLER. KETTLE & POT FISHER 2040 S&G PC PC --- ■-.■ ® 36 1/2 36 _- I ___ 25.1 STAND. KETTLE GROEN TS /9 -2 F/ TDB /C -40 S&G S&G -- ' --- ___ 25.2 26 1 RANGE. HEAVY DUTY, GAS JADE RANGE !TRH-6-36 SdcG SdcG PC -.111111 - IIIIIIIIII MI 111113111111 215 30.5 I _-- _____ 26 27 1 OVEN. CONVECTION. GAS BLODGETT OVENS DFG100 DOUBLE S&G S&G EC 10.0 1/3 120 1 60 X 5 -15P 33 3/4 55 10 27 10.0 1/3 120 1 60 X 5 -15P 66 1 II 3/4 55 42 28 3 KITCHEN SWING DOOR EUASON LWP -3 SdcG SdcG - I __- __-■_.■ 28 29 2 SINK, HAND ADVANCE TABCO 7 -PS -60 S&G Km PC I-_ .-.. 11/2 21 1/2 21 1 -1/2 26 -- I 29 30 1 EXHAUST HOOD - SPRING -MR CUSTOM (PREP) 16' S&G S&G EC - MC FROM CONTROL PANEL I 10X10 618 .2 104 10X14 1550 1.5 104 30 . 10X10 618 .2 104 30.1 1 EXHAUAST HOOD FAN SPRING -AIR CUSTOM INCLUDES #10.1 & 194.1 LOAD SdcG S&G EC -S&G I 6.1 2.0 208 60 X OUNCT 3550 2.0 - 30.1 31 1 FIRE SUPRESSION - PREP UNE ANSUL CUSTOM USES #95 UTILITIES SdcG S&G SdcG I USES 05 UTILITIES VERIFY, GAS DISCONNECT 31 32 2 CART, BANQUET SERVICE CRES COR H- 137- S- 96--BI S&G S&G - 12.0 1.5 120 1 60 X 5 -20P 48 10 FT CORD 32 33 1 SUCER, FOOD GLOBE FOOD EQUIPMENT 3600 SdcG S&G - 7.0 1 /2 115 1 60 X 5 -15P 48 33 34 1 TABLE, WORK ADVANCE TABCO KAG --304 SdcG S&G - 34 35 1 SINK, PREP METAL FAB 2C23X23 -224 S&G S&G PC 2 12 MR -GAP TO FS 35 35.1 1 FAUCET. WALL MOUNT FISHER 3253 SdcG S&G PC 1/2 18 1/2 18 35.1 36 1 LT SHELVING, WIRE INTERMETRO INDUSTRIES 14428R S&G S&G - 36 37 1 SOIL DISH TABLE METAL FAB CUSTOM S&G SdcG PC 37 38 1 CLEAN DISH TABLE METAL FAB CUSTOM SdcG SdcG - 38 39 1 WAREWASHER, RACK CONVEYOR HOBART US FOODSERVICE C44A +BUILDUP S&G S&G EC -PC 11.1 2.16 208 3 60 X 65.5 3/4 64 2 7 HT WTI? F/ 141. MR -G•P TO FS 39 40 1 PRE - RINSE, WALL MOUNT FISHER 2210 -WO SdcG PC PC 1/2 18 1/2 18 40 41 1 WATER HEATER. BOOSTER HATCO C -27 S&G S&G PC & EC 75.0 27.0 208 3 60 X 8 3/4 271 8 3/4 12 SUPPLY TO #39 ; BLOW-OFF TO FS 41 42 1 LT SHELVING, WIRE INTERMETRO INDUSTRIES 1448BR SdcG S&G - ( 42 43 1 DUCT HOOD (D/W) METAL FAB CUSTOM SdcG S&G -- 4X16 400 .5 VERIFY W/MECH. 43 4X16 200 .50 44 2 FAUCET, WALL MOUNT FISHER 3253 SdcG PC PC 1 /2 18 1 /2 18 44 45 1 3 COMPARMENT SINK METAL FAB CUSTOM SdcG S&G PC 2 12 WASTE TO CODE 45 2 12 2 12 46 1 SINK, MOP ADVANCE TABCO 9 -OP -20 S&G PC PC 3/4 36 3/4 36 2 0 46 47 1 SHELVING, WIRE, DRY STORAGE INTERMETRO INDUSTRIES LOT S&G S&G - 47 49 1 CO2 TANK BY VENDOR OUTSIDE FILLER VEN VEN VEN 49 50 1 SHELVING, WIRE, LOCKED UQ. STOR. INTERMETRO INDUSTRIES SEC56CQ S&G S&G - I 50 51 1 SINK, DROP -IN ADVANCE TABCO DI -1 -10 SdcG PC PC 1/2 21 1/2 21 1-1/2 26 51 52 1 TRASH CAN REFRIGERATOR, UC, COMPACT RACK (CUP) STORAGE DOLLY. DISHRACK ESPRESSO EQUIPMENT GRINDER RUBBERMAID SUM JIM BEVERAGE -AIR UCR20 MILLWORK CUSTOM CRES COR 501 -D ESPRESSIMO (SPEC ?) TBD WTR FILTER? ESPRESSIMO (OTHER) 6258 (TBD) MILLWORK CUSTOM CECILWARE SD1 ADVANCE TABCO DI -1--10 SdcG H SdcG H - - - - EC-PC - - 3.5 I-_-_■ I-r 1 15.0 I 8.0 -- 1 /6 1 /3 120 115/208 115 1 1 1 8 `8 8 X 5 -15P 12 I 52 53 53 54 1 1 54 55 1 f 55 56 1 X 24 VERIFY 1/4 34 3/4 34 AIR --GAP TO FS 56 57 1 X 5 -20P VERIFY 57 58 1 SERVICE COUNTER SYRUP WARMER 58 59 60 61 1 0 1 - PC I 0.1 120 1 X 5 -15P 48 59 SINK, DROP-IN 1/2 21 1/2 21 1-1/2 26 60 RACK (CUP) STORAGE MILLWORK CUSTOM GC GC - 61 62 1 COFFEE MAKER, SATELUTE SYSTEM BUNN- O -MATIC DUAL 000011 SdcG S&G - 62 63 1 WARMER NEWCO GWT MILLWORK CUSTOM INTERMETRO INDUSTRIES 1460BR S&G GC S&G S&G GC S&G - - - 120 X 5 -15P 48 VERIFY I 63 64 65 64 1 INSIDE SERVICE COUNTER 65 1 SHELVING, WIRE 67 1 BEVERAGE COUNTER MILLWORK CUSTOM GC GC - I 67 68 1 GLASS RACKS MILLWORK CUSTOM GC GC - I-_- -■-.. I----. . _- I --- ^ ': 1 68 69 1 DROP -IN. WATER & ICE STATION DELFIELD 204 IMI CORNELIUS CB- 2323 -6 TWR DROP -IN VERIFY S&G VEN PC VEN PC VEN 1/2 34 1/2 24 MR- GAP TO FS 69 70 6.0 120 1 60 X 5 -15P 24 VERIFY 3/8 24 3/8 1/2 33 14 11 I VERIFY 70 1 DISPENSER, ICE /BEVERAGE 71 1 ICE TEA DISPENSER CECILWARE S2 S&G S&G S&G S&G - - 11 III 71 72 72 74 © 1 SHELVING. WIRE SODA RACK STORAGE INTERMETRO INDUSTRIES 144888 BY VENDOR TBO VEN VEN VEN I--- .-.■_ --_-- -- 1 --- --- __ --_ 74 75 1 PANTRY ISLAND METAL FAB CUSTOM S&G S&G SdcG S&G S&G EC - I - 10.0 EC 4.9 1.2 1.0 120 208 .-.. 1 1 60 60 X 5 -15P X 48 12 ---- II . _- I I 75 76 77 76 1 WARMER, FOOD, ELECTRIC DUKE ACTW -1 WELLS RW -36 77 1 WARMER, DRAWER TYPE 78 1 REFRIGERATOR, UC, COMPACT TRUE F000 SERVICE TUC -48 SdcG SdcG - I 9.0 1/3 120 1 60 .© 5 -15P 12 W/ CORDSET _---- . _- I __- --- 78 79 1 DIPPERWELL ASSEMBLY FISHER 3041 KELVINATOR 8 -5 MANITOWOC ICE QY -1804A SdcG S&G S&G S&G PC S&G S&G S&G PC I - EC -PC PC _ 5.0 28.1 - - 1/4 ' -1/ - _. 120 208 60 60 X 13/8 X 5 -15P 12 92 3/8 34 !!! _ -- r - 3/4 1 /2 1 26 67 6 _ - AIR -GAP TO FS I MR-GAP TO FS -- -i --- 79 80 81 8 . ,. , tt 80 1 ICE CREAM CABINET 81 1 ICE MAKER W/O BIN 81.1 1 BIN, ICE MANITOWOC ICE F- 1300 -48 81.2 1 FIL TER, WATER MANITOWOC ICE TRI- L -25NH ADVANCE TABCO 7 -PS -60 S&G S&G PC S&G PC PC 3/8 1/2 76 21 1/2 21 1 -1 /2 26 .375 INLET & OUTLET 82 1 SINK, HAND 82 1 SINK, HAND ADVANCE TABCO 7 -PS -60 S&G PC PC 1/2 21 1/2 21 1-1/2 26 83 1 REFRIGERATOR, SALAD PREP TRUE FOOD SERVICE TSSU -72 -18 S&G S&G - 1 11.0 1/2 120 60 X 5 -15P 12 W/ CORDSET 83 • • • • • • tQU I PM UITJ CHEDULE 0 • v EL 4 c.1 >s itZ) co m Zr z ° � z � co mt z thld u Z IZ) � w � . 4 in ND 0 is) al ‘..c) cNa -sr U 6� 3 1 7 __ V) 0 f- Q -101 - KITCHEN PLAN Q -102 - SCHEDULES Q-103 - ELECTRICAL Q -104 - PLUMBING Q -201 - ELEVATIONS Q -202 - ELEVATIONS 0-501 HOOD DRAWL Q -504 -HOOD DRAWINGS scot, N/A aft 12/13/02 ft"' 0-102.1 4 ITEM NO QTY EQUIPMENT CATEGORY MANUFACTURER EQUIPMENT MODEL NUMBER REMARKS 436BOtldN U N UNJI 9. JI JI N N CI La I- La C.) Z m z o V) a ¢ x z Cn I- J } PHASE 310A0 310100 8 8 8 8 8 . DIRECT l J ixix' LLLL < m ELI z N ELECTRICAL `O ^' AFF (IN) ELECTRICAL REMARKS COLD WATER SIZE (IN) I A�F CIN) TER HOT WATER SIZE (IN) I GPH WATER HOT WATER AFF (IN) DIRECT DRAIN SIZE (IN) DIRECT DRAIN AFF (IN) INDIR DRAIN SIZE (IN) INDIR DRAIN tO AFF (IN) (NI) 3ZIS Sb'D MBTUH � (NI) SVOI PLUMBING REMARKS CL =- W Y N 'Q _ 2 u 0 <0 12 > I W Y Q 2 0 <M z o > I W 2 (Jo a i i ai D I W 2z C) < z a , �? D` = N X - WV) 01- <U o i% D = X W o d rt o fn D z X W V a 3 �r v) iV D = X.-. WZ O" < x< HVAC REMARKS ITEM NO MR-GAP TO FS 84 6 -20P PC 14.4 3.0 208 84 1 TABLE, HOT FOOD REFRIGERATOR, PREP DUKE MANUFACTURING TRUE FOOD SERVICE E304SW 85 5 -15P - - 11.0 14.0 1/2 120 W/ CORDSET STS U -72 -18 85 1 86 5 -20P 1.7 120 86 1 OVEN, MICROWAVE PANASONIC NE -1021 MS -18 -24 87 - 87 1 SHELF, MICROWAVE ADVANCE TABCO , • 88 5 -20P - 16.8 2.1 125 W/O CORD & PLUG 88 1 OVEN, SLOW COOK /HOLD ALTO -SHAAM , 750 -TH -II 89 5 -15P - 0.3 120 89 1 CARVING STATION CARUSLE HL81958 ' 90 - 14368R 90 1 SHELVING, WIRE INTERMETRO INDUSTRIES 91 EC - 1.4 120 91 2 WARMER, FOOD OVERHEAD HATCO GRAN -48 -D CUSTOM 92 -- 1 DBL PASS SHELF SSP 92 93 - 93 1 1 TABLE. WORK ADVANCE TABCO KAG -303 10X29 1740 .20 104 10X20.5 2175 1.5 104 94 POWER FROM CONTROL PANEL. NO FAN EC -MC EXHAUST HOOD (COOKUNE) SPRING -AIR CUSTOM - RIGHT 94 10X29 1740 .20 104 EC -MC POWER FROM CONTROL PANEL, NO FAN 10X13 800 .20 10X19 2000 1.5 94.1 94.1 1 EXHAUST HOOD ( COOKUNE) SPRING -AIR CUSTOM - LEFT l I -IMI" I I 11 I -1 I' 11 1 888 8 8 88 I Ixlxlxl I lx1 I I lxl 1xlxl 1 1 10X13 800 .20 EC -PC 20.0 120 96 VERIFY VERIFY, GAS DISCONNECT 95 95 1 FIRE SUPRESSION - COOKLINE ANSUL CUSTOM EC -MC 9.1 3.0 5.0 208 OUNIT 3550 2.0 - 95.1 95.1 1 EXHAUAST HOOD FAN FOR #94 208 MC r 14.0 30 OUTDOOR CONNECTION 3/4 400 24 7" W.C. 16X36 7120 .7 95.2 95.2 1 MAKEUP AIR SYSTEM SPRING -AIR SFA18 -1 GOD 96 _ - PC 1 RANGE. SPREADER JADE RANGE . JTPR -36 96 1/2 31.5 3/4 150 31 REAR CONN., TO FRONT MANIFOLD 97 1 OPEN BURNERS /REFRIG. RAIL JADE RANGE JMSS- 05 --T -60 REMOTE REFRIGERATION 97 5 -15P 12 FAN ONLY; 2700 BTU LOAD REMOTE REFRIGERATION 98 PC 3.2 120 1 1 REFRIGERATOR. SHORTY JADE RANGE JRLH- 04R --T -54 98 - PC 3/4 35 31 FACTORY CONN. TO FRNT MANIOLD ON #97 99 SALAMANDER BROILER, GAS JADE RANGE JSB -36RM 99 1-1/4 180 31 FRONT MANIFOLD TO #110 do 97 100 100 1 RANGE, GRIDDLE, GAS JADE RANGE JMRH -72GT 3/4 35 75.5 FACTORY CONN. TO FRNT MANIOLD ON #100 101 - 101 1 SALAMANDER BROILER, GAS JADE RANGE JSB -36 12 FAN ONLY; 2900 BTU LOAD REMOTE REFRIGERATION 102 PC 3.2 120 1 REFRIGERATOR, SHORTY JADE RANGE JRLH- 04R -T -72 102 -1/4 180 31 FRONT MANIFOLD TO #105 103 PC PC 3.2 1 RANGE, BROILER, GAS JADE RANGE JMRH -72B 103 12 FAN ONLY; 2900 BTU LOAD REMOTE REFRIGERATION 104 120 1 REFRIGERATOR, SHORTY JADE RANGE JRLH- 04R -T -72 104 15.0 1.0 208 EC OUNIT VERIFY 104.1 104.1 1 REMOTE REFRIGERATION BY ERICKSON REFRIGERATION COOKUNE REFRIGERATORS 1-1/4 - 31 FRONT MANIFOLD TO #106 105 - PC 105 1 FRYER, DUMP STATION JADE RANGE JTDS -18 3/4 220 31 REAR FEED, FRONT MANIFOLD 106 1 FRYER, DEEP FAT. GAS JADE RANGE JTFF- 240 -36 106 _ 107 - 107 1 TABLE, WORK ADVANCE TABCO KAG -243 108 1 TOASTER. CONVEYOR (FUTURE) HATCO TQ -1200 VERIFY MAKE /MODEL 19.4 4.0 208 1 60 X 6 -30P 48 VERIFY 108 109 4 WALL CAPS & CORNER GUARDS METAL FAB CUSTOM SdcG S&G - 109 110.1 1 WALL PAD METAL FAB CUSTOM COOK UNE S&G S&G - _ 110.1 110.2 1 WALL PAD METAL FAB CUSTOM PREP UNE S&G S&G - _ 110.2 BOO _ 1 UNDERBAR MODULAR BAR DIE PERUCK MBV36 S&G S&G EC -PC BOO B02 1 UNDERBAR GLASS RACK GLASTENDER DBGR -18 CBA- 36L -CP8 PC 1-1/2 28 MR-GAP TO FS V B02 PC 1-1/2 14 UNIT HAS 10- CIRCUIT BEVERAGE COLD PLATE. AIR -GAP TO FS r.' 1 _ 7:. .J3 803 803 2 UNDERBAR COMB. ICE BIN GLASTENDER . - _ _ 1 -1/2 14 B04 1 UNDERBAR FILLERS & DRAINBOARDS UNDERBAR BLENDER STATION GLASTENDER GLASTENDER ICCB -45 BSA -18L MF24 -SF2 - NNN PC _ 1 1 _ X X - 29 1-1/2 28 23 MR-GAP TO FS n * • ; _, B04 805 AIR -GAP TO FS 1---- - - - -1/2 5 -15R 17.5 PROVIDE GA OUTLET FOR BLENDER 3/8 29 3/8 120 PC -EC 15.0 B05 _ 2 B06 5 -15P 6 6 FOOT CORD W/ PLUG PROVIDED 8.2 1/3 120 - B06 2 FROSTER GLASS /MUG GLASTENDER B07 1 UNDERBAR DRY WASTE GLASTENDER DW13-12 S&G S&G - AIR -GAP TO FS B07 B07 1 UNDERBAR DRY WASTE GLASTENDER OWB -12 SdcG S&G - 1307 808 2 UNDERBAR GLASS RACK GLASTENDER DBGR -24 S&G S&G PC -1/2 27 MR-GAP TO FS B08 B09 1 GLASSWASHER GLASTENDER GT- 24 -CCW -208 NN PC -EC 3.5 4.0 120/208 1 60 X 7.5 HEATER & POSER LIGHT OPERATE ON 206V (311MIP DEDICATED CIRCUIT) ALL OMER COMPONENTS ON 120/, 3/8 7.5 3/8 7.5 -1/2 7.5 SEE SPEC (MANY REQ'S.) 809 PC 3/8 _ 29 -0 -3/ 29 -1/2 18 DRAIN IS WET WASTE; DECK MTD. FAUCET & UFT OUT PERFORATED WET WASTE STRAINER INCLUDED. 810 1 UNDERBAR SINK . GLASTENDER SWB -12 -C B10 PC 1 -1/2 27 MR-GAP TO FS 811 1 UNDERBAR FILLERS & DRAINBOARDS GLASTENDER IFC -24/24 811 812 1 BACK BAR COOLER GLASTENDER 8896 -N S&G S&G PC-EC 120 1 60 X 30 15 IMP OWED CIRCUIT; AE( EIQ 1/3 HP C01D16>ING LINT RATED AT 3,250 E1111/11 AT 32 DEGREES F. 1/2 25 20"X 1/2" I.D. UNE DRAIN THROUGH ACCESS HOLE IN WALL. 812 812.1 1 REMOTE REFRIGERATION BY ERICKSON REFRIGERATION PART OF #2.1 UNIT SIG SdcG EC VERIFY _ 812.1 813 814 815 1 1 BACK BAR COOLER GLASTENDER RF72 -N6 -N NNMN NN;;, V � 120/208 1 1 _ 1212_ _ X X _ 34 � M! 1 I I I I AIR -GAP TO FS 813 814 1 2 / 41 BEER DRAIN CONN. EXITS REAR OF DRIP TRAY. BT -fi -MF TBD WTR FILTER? UNDERBAR BEVERAGE TOWER GLASTENDER 24 VERIFY 1 /4 3/4 34 VERIFY, MR-GAP TO FS 815 15.00 8.0 1 ESPRESSO EQUIPMENT BY VENDOR 5 -20P VERIFY 1/3 115 816 FT1 FT2 816 FT1 FT2 1 1 1 GRINDER FLOOR TROUGH (PREP UNE) FLOOR TROUGH (ICE MACHINE) BY VENDOR EAGLE EAGLE (TBD) FT- 1884 -SG FT- 1248 -SG NECK OF WASTE CUP ACCOMMODATES UP TO 3" PIPE NECK OF WASTE CUP ACCOMMODATES UP TO 3" PIPE ` POS 1 POS _ BY OWNER TBD OWN OWN - 20.0 120 1 60 X 5 -15P 24 VERIFY, DATA UNE _ . POS a • rQu I PM UITJCH Wu LE • : Q U I P M E N T S C H E D U L E M �OI 9 • acv OF n arooLA F EB 0 4 2003 CONTeR I Q -101 - KITC.1 -IErsi PLAN Q -102 - SC1-IEDULES Q -103 - ELECTRICAL Q -104 - PLUMBING Q -201 - ELEVATIONS Q -202 - ELEVATIONS Q -501 - HOOD DRAWI Q -504 44000 DRAWINGS soft N/A 12/13/02 I • • • C FOOD3ERVICE ELECTRICAL NOTES A ALL ELECTNIGAL OUTLETS SHOW ON TllS PLAN M8: FOR FIXTURES AND EQUIPMENT SPEWED AS FURNISHED BY THE FOOD SERVICE CONTRACTOR (ESC), UNLESS OTHERWISE NOTED. FOR MY ADOITIO NAL OOMENIENCE OUTLETS, SEE OTHER ELECTRICAL DRUM E REQUIREMENTS. 8 ALL MOWS GWE N ARE FROM COLUMN CENIVENE MW.LS A NO . ELEiMTIONS OPEN ARE FROM Men FLOOR TO =RUNE OF OUTLET. ALL OUME TO BE SET VERTICALLY. ALL 120U OUTLETS NOT DESIGNATED MN SPECIFIC LOADS TO OE RATED AT 15 AMPS WITH MINIMUM LOOPING. C ALL ROUGH -NS SHORN ARE TO BE RUIN INSIDE EN.LS (EXCEPT STUB -UPS). LOCATIONS INDICATE POINT OF COT FROM MALLS, COLIC OR FLOOR. D ELECTRICIAN TO BRANCH TO CONNECTION WHERE REQUIRED MD TO CONNECT ALL ELECTRICAL EQUPIENT AND FIXTURES TWO DO MY I4TERE& SIRING REQUIRED N THE FIXTURES INCLUDING MERMRNG TO APPLMNCES AS REQUIRED BY DE SPECIFICATIONS MD /OR GRANINIQ$. E FOOD SEANCE CONTRACTOR TO FURNISH GALVANIZED JUNCTION BOOZES N FIXiUAE CUT -OUTS AS REQUITED BY THE ITEM SPECIFICATION NO INCLUDE APPROPRIATE ELECTRICAL RECEPTACLE. S/'S FACE- PLATE. WHERE BUILT --N mar BREMTER SUB- pWE'LS EWE CANED FOR N THE 11Th SPWIACATi0NS. THE KITCHEN EQUIPMENT SUPPLER 6 TO PROVIDE NO INSTALL TH6 PAiE'L ALONG MATH THE PROPERLY 92ED CIRCUIT GROWERS. F AL ELECTRICAL OUTLET COMER PLATES ARE TO BE STARLESS STEEL. THOSE REQUIRED N BUILDING STRUCTURE ARE TO OE FURNSHED IN THE ELECTRICIAN. WITH RECEPTACLE. ALL MAN BREAKER PANELS AND DISCONNECT SIMITCHES REQUIRED BY OTHER ELECTRICAL DRAWINGS ARE TO BE FUMED BY MO INSTALLED BY THE ELECTRICAL CONTRACTOR AT THE OF P6TAL ATION. G F ELECTR CP4. COOKING EOUPIENT iS SPECIFED. ELECTRICAL. CONTRACTOR TO ROME DE-EL MINING BETWEEN FIRE PROTECiION BOTTLE CONTROL HEAD. MICRO- SWTTCH MO COOKING EQUIPMENT TO COMPLY WITH APPUC I E LOCH. CODE REQUIREMENTS FOR EEERfENCY SHUTDOWN OF ENTIRE COOIQJNE. SHUNT TRIP CNICXJflRRY WAY BE REQUIRED. SEE OTHER ELECTRICAL RMS. UNLESS OTHERWISE NO CITED THE ELECTIEr,AL LOADS SPECIFIED ARE THE CONNECTED LOADS FUSE OR CIRCUIT BREAKER SOX TO BE DETERRED ACCORDINGLY. BASED UPON APPLICABLE CODE REQURENDLIS. OMNSSIONLS OR ERRORS N THE SCHEDULE DOES NOT ME* ELECTRICAL CONTRACTOR FROM COM PLE!E AND CXRRECT FINAL CONNECTION RESPONSEWIY. REUEW OF EQUPM DDT BROCHuRE BOOK AND SHOP ORAwNNU" 5 MIL ASSURE CORRECTNESS OF THIS WORK. J ELECTRICAL CONTRACTOR TO PROVIDE AND INSTAL ALL SWRTC E5, STARTERS, DISCONNECTS, ETC. FOR ALL EQUPUENT UNLESS ESS NOTED O ID ASE. ALL DISCONNECTS OR LOCK -OUT DEVICES. STARTERS„ ETC. TO MEET N.E.C. RID O.S.HA STANDARDS. K ALL RECEPTACLES SWILL BE GROUNDED PER N.E.C. MID 0.S.MA RD TO HAKE NO GROUND FN1LT PROTECTION. L ELECTRICAL CONTRACTOR TO PROVIDE CONTROL WNUING MID ELECTRICAL SERVKE FOR REMOTE REFRIGERATION SYSTEMS FOR WALK -IN BOXES. ALSO COORDINATE LOCATION FOR SERVICE MIH THE ELEC1RCAL ENGINEER M ELECTRICAL CONTRACTOR TO PRONE( ER* AROUND HEATER CAM ON ALL EWPORATOR ORN LINES LOCATED THIN WALK -N FREEZER OF APPUCABLE). ELECIRCAL CONTRACTOR TO MALL RID ME DMA UGHTS PRCARED t J DOOR SW TtIL ( 3 UGM MAA S FOR UOIN MO 2 WELTS FOR FRREEZERN ) MMiLK -N EMS AS REGIMRFD, O ALL THREE (3 PHASE POKER CONNECTIONS TO BE ON A FOUR (�4) WIRE SYSTEM AND Mi SINGLE (1) PHASE POWER TO BE ON A (3) THREE WARE SYSTEM (UN ESS NOTED OTHERMRSO. P VEI FY WITH ARCHITECT OR FOOD SERVICE CONS. LUNT, THE FINAL MOPE D° REQUIlaENTS BEFORE ORDEWNG MATERIAL. REVISIONS TO Eg1PMENf OR PERFORIRECE REQUIRDENTS MAY AFFECT THE ELECTRONS WORK. Q Ni L WORK RELATING TO THE NSTF11ATION & HOOKUP OF THE SIDED EQUIPMENT, IS TO BE PERFORMED N FULL iVGCORDANGE METH APPUCPaE aTY. COUNTY, LOCAL. STATE a FEDERAL CODES NO ALL OTHER GOVEMMENTTAL REGULATORY REQUIREMENTS. R ELECTRICAL CONTRACTOR IS REQUIRED TO FURNISH NO INSTALL ALL ELECTRICAL COMPONENTS INE(ESSARY TO PROVIDE SERVICE TO LOCATIONS & EQUIPMENT SHORN ON THIS SHEET UNLESS NOTED OTHERWISE_ ELECiRICaL CONTRACTOR N5 ALSO RESPONSIBLE FOR MAKING FINAL CONNEC110NS TO EQUIPMENT AND FITTINGS SUPPLIED AND INSTALLED Eft' THE ICES Klan EQUIPMENT SUPPLER). S ELECTRICAL CONTRACTOR TO PiOAIIDE ISOLATED GROUND CIRCUIT FOR ALL P.O.S. REGISTERS. COMPUTERS MID \PRINTERS. . NOTE 'C' ALL HALL MOUNT ELECTRICAL REGEPTICL.ES AND J -BOXES ARE TO BE FLUSH HOLMTED IN WALLS 111TH NO EXPOSED CONDUIT 5HOWIN& ON SURFACE OF WALLS. "CONVENIENCE OUTLET REQUIREMENTS C.ONI 120 -V, I -PH SERVICE, 15.0 AMP, STUB OUT HALL AT +48" A.F.F., CONVENIENCE OUTLET. CON2 120 -V, I -PH SERVICE, 15.0 AMP, UNDERBAR AT +36" A.F.F., CONVENIENCE OUTLET. CON3 120 -V, I -PH SERVICE, 15.0 AMP, STUB OUT WALL AT +12" A.F.F., CONVENIENCE OUTLET. 5. I+IO'T USED ELECTRICAL NOTES I. BELTRJGAL PLAN SHOPS R01.1614-114 C.GMILT10N LOCATIONS 11711 GAPAGtTIES. SEE DIMENSIONAL DR 4111105 RJRNSHl 7 D1t' THE KITCHEN EQUIPMENT CONTRACTOR POR ACTUAL ROU6H-IN LOCATIONS. 2. ELECTRICAL SYST -1 IS DE516mD FOR I20l2015 VOLTS. I t 3 PHASE, 6 HERTZ, 4 MIRE SYSTEM. 3. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL ALL JUNCTION BOXES, REGeer/ COVER PLATES, PILL BOXES, CONDUIT AND WIRING EXCEPT MERE NOTED. 4. ALL CONDUIT RUNS INDICATED FOR REFRIGERATION, DRINK APO LIQUOR SYSTEM LIMES SHALL we RIIRIIisHeo AND IIKSTAU.ED BY TIE ELECTRICAL DIVIsION. GC7HDUIT SHALL HAVE 24' *COMM) MINIMUM RADIUS COOS. b. KITCHEN EQUIPMENT CONTRACTOR SHALL 191110411514 AND INSTALL VAPOR mods VENTILATOR LI614T5 COMPLETE MTH LAMPS. INTERCONNECT** CONDUIT, Ma* AND MAALL SMNITGIN ruwespeo AND INSTALLED BY THE ELECTRICAL DIVISION. 7. ADDITIONAL COMMERCE IRE CE!PTAGL 5, TELEPHONE AND INTERCOM JACKS SHALL CE LOCATED BY 71E ARCHITECT, AND AS REGUIRm EMnr GODE. 6. KITCHEN EQUIPMENT CONTRACTOR SHAWL PM4NI'SM DISPOSER CONTROLS. ELEGTRIGAL DIVISION SHALL PIP Pille11914 NC INSTALL NT RCONM- EGTN6 CONDUIT ND MIRE BETHIEIBI SPSTCM. DioroSER AM COMPONENTS. ,. 4EGTRICAL DIVISION SHALL FURNISH AND INSTALL ALL INTERCONNECT** CONDUIT AND MRR EeTPEEN FNG TCM PURIM ISH TED PITH PIKE SUPPRESSION SYSTEM SUPPLIED BY THE KITC4 I E[IAPMBIT CONTRACTOR AND CONTACTORS PU RPI SHED BY THE EL C.TRNGAL DIVISION 10. ELECTRICAL. DIVISION TO RJRNISM AND INSTALL. INTERCO1IDGTN6 CONDUIT NV Moos (2 NINE 24 VDTW BET7415194 MAIM M PAM/!. AND COLD 'TOR- ASE ROOM THERMOSTAT. PANEL NO 711!A0105TAT RIA'NNSHED AND INSTALLED D BY THE KNTGNEIN RtilPMENT CONTRACTOR. II. PAIEfAaRIGATED GOLD STORAGE ROOMS ARE RJRNSHlD BY TiE KITCHEN EGIAPMI<NT CONTRACTOR COMPLETE 1111714 SPUGE BORES, LIUMT FIXTURES, LAMPS, LOOT SNTCHES AND DOOR WARM. ELEGflNGRL ENVISION TO INSTALL "SAME ANC SHALL PUAOISH MO INSTALL INTERCOMECTINS co,wT, MNS SE/ALCMS, IEALAIfr MID MAKE NMAL cOIIINDGnoNs. 12. EL.ECTRK.M. DIVISION SHALL PUAOMSM INCH I116TALL ALL INTERGON EC711 AUM CONDUIT ANC MFRS BETMEE N ICITC4404 EQUIPMENT CONTRACTOR RP M- NSHED LORI TEMP COLD STORAAE N OCTM EVAPORATOR TEPO IiM1L BLOCR. eirrat PAN DOOR SMITCN A10 COPINIESsoR CONTROL PAWL. .. neGTRHGAL DIVISION SMALL P1IIRPIRSI1 MO INSTALL EMPTY CONDUIT PITH JNCTIOPI eolls POOR NOTALLAT OPI oP 01'NNER SUPPLIED ELECTRONIC GASH CONTROL SYSTEM. ElleG11OGAL DIv*CH TO VERIFY INSTALLATION PI AIGGORDAN.E M7N omP S TS APO HrLi TIVAGTUIERS IPSTRILIcTION D. 14. ILIGTILICAL. DIVISION SHALL PlIINISH AND WALL. AN A{ROMMTHG carom G11 POR ALL ll,NG710GIIL GA IDNIS UNDER MOD TO B f .TNA7lD NMI PIE SIP ARM SIO N SY 7M comes ow rr- • rL � N/ ITEM NO QTY EQUIPMENT CATEGORY 1 1 WALK -IN COOLER /FREEZER 2 1 EVAPORATOR COIL COOLER 2.1 1 COMPRESSOR, COOLER 6 1 WALK -IN FREEZER 7.1 7.2 10 13 19 23 24 25 30 30.1 32 32 33 41 48 53 1 56 1 57 1 63 1 70 1 76 1 77 1 78 1 80 1 81 NOTE 'A' 1 EVAPORATOR COIL, FREEZER 1 1 1 1 1 1 1 1 1 1 1 1 1 1 COMPRESSOR, FREEZER SMOKER MIXER, COUNTER REFRIGERATOR, REACH -IN OVEN, SLOW COOK /HOLD TILT SKILLET KETTLE, STEAM JACKETED EXHAUST HOOD EXHAUAST HOOD FAN CART, BANQUET SERVICE CART, BANQUET SERVICE SUCER, FOOD WATER HEATER, BOOSTER SPARE REFRIGERATOR, UNDERCOUNTER, COMPACT ESPRESSO EQUIPMENT GRINDER WARMER DISPENSER. ICE /BEVERAGE WARMER, FOOD, ELECTRIC WARMER, DRAWER TYPE REFRIGERATOR. UNDERCOUNTER, COMPACT ICE CREAM CABINET iCE MAKER W/0 BIN 2013V, I PHASE, SERVICE, 10.0 AMPS, STUB AS NOTED, CONFECT AT POS/PRE -CHECK STATIONS. (DEDICATED CIRCUIT, ISOLATED GROUND, ADD PHONE LINE, PROVIDE EMPTY J-SOX WITH GWNPUIT FOR INTERC.ONPEGTING P05 SYSTEM, PRE -GHECK AND PRINTERS) NEPJFY ALL REQUIRMENTS WITH P05 SYSTEM SUPPLIER) NOTE 'B' ALL CONDUIT SHALL BE RUN ON THE EXTERIOR CEILING OF ALL GOLD STORAGE ROOMS AND SHALL PENETRATE THE CEILING AT A POINT WHERE THE CONDUIT CAN DROP DIRECTLY TO THE POINT OF CONNECTION. ELECTRICAL CONDUIT SHALL NOT BE RUN ON THE INTERIOR. ELECTRICAL SYMBOLS 0 FIXTURE MOUNTED .JUNCTION BOX 0 FIXTURE MOUNTED RECEPTACLE (2) DUPLEX RECPT., 120 -V, EMPTY J -BOX WITH CONDUIT INTERCONNECTING P.0.5. PRE -CHECK 6 PRINTERS, ADD PHONE LINE FIXTURE MOUNTED ELECTRICAL PANEL INCANDESCENT LIGHT FIXTURE FLUORESCENT LIGHT FIXTURE FIELD WIRING RUNS ®11 FIRE SUPPRESSION MANUAL PULL STATION EMPTY -BOX WITH I/2" CONDUIT RUN IN WALL UP THRU CEILING TO ATTIC SPACE ELECTRICAL SYMBOLS 0. DUPLEX RECEPT., 20 -AMP, 120 -VOLT, GROUND TYPE, VERTICALLY MOUNTED ei SIMPLEX RECEPT., 20 -AMP, 120 -VOLT, GROUND TYPE, VERTICALLY MOUNTED (� SPECIAL PURPOSE OUTLET, VOLTAGE AS INDICATED, GROUND TYPE, VERTICALLY MOUNTED II- HARD WIRE CONNECTION POINT al JUNCTION BOX, VERTICALLY MOUNTED • ELECTRICAL CONDUIT, STUB AS INDICATED FOR DIRECT CONNECTION O FLOOR/CEILING RECEPTACLE AS INDICATED 44 SIM I at 20.0 5.0 15.0 20.0 8.0 25.0 8.0 8.2 9.0 28.8 6.0 5.0 30.0 10.8 6.1 12.0 12.0 1.5 7.0 75.0 27.0 3.5 15.0 8.0 6.0 10.0 1.2 4.9 1.0 9.0 5.0 28.1 4 • • 1/2 1/2 2.0 1.5 U W U � 120 1 60 X 120 _ 1 60 X 1/2 208 3 60 X 120 1 60 X 208 1 60 X 2 -1/2 208 3 60 X 120 1 60 X 115 1 60 X • 120 1 60 X 208 1 60 X 120 1 60 X 208 3. 60 X 1/2 208 3 60 X OUNIT 120 1 60 X 5 -20P 48 120 1 60 X 5 -20P 48 10 FT CORD 115 1 60 X 5 -15P 208 3 60 X 8 1/6 120 1 60 X 5 -15P 12 115/208 1 60 X 24 1/3 115 1 60 X 5 -20P 120 X 5 -15P 48 120 1 60 X 5 -15P 24 VERIFY 120 1 60 ,X 5 -15P 48 208 r 1 60 X 12 1/3 120 1 60 X 5 -15P 12 W/ CORDSET 1/4 120 1 60 X 5 -15P 12 3-1/2 208 1 60 X ELECTRICAL Z 5 -15P 5 -15P 7 C { j • f I r i ELECTRICAL w REMARKS 104 UGHTS CONTROLS 80 *UNIT VERIFY, DON'T DUPUCATE 104 UGHTS & CONTROLS 80 HEAT TAPE DRAIN OUNIT VERIFY 12 ALSO AVAILABLE AS 230V 12 W/ CORDSET 73 208 -240V 30 4 FROM CONTROL PANEL VERIFY VERIFY VERIFY • NO 2 2.1 6 7.1 7.2 10 4 13 19 X 23 24 25 30 30.1 32 32 33 41 48 53 _56 ,57 63 70 76 77 78 80 81 SCH E D U L E ITEM NO Q1Y EQUIPMENT CATEGORY 83 1 REFRIGERATOR, SANDWICH /SALAD PREP 84 1 TABLE, HOT FOOD 85 ` 1 REFRIGERATOR, SANDWICH /SALAD PREP 86 1 OVEN, MICROWAVE 88 1 OVEN, SLOW COOK /HOLD 89 1 CARVING STATION 91 2 WARMER, FOOD OVERHEAD 94 1 EXHAUST HOOD (COOKUNE) 94.1 1 EXHAUST HOOD ( COOKUNE) 95 1 FIRE SUPRESSION 95.1 1 EXHAUAST HOOD FAN 95.2 1 MAKEUP AIR SYSTEM 98 102 104 104.1 108 B05 2 806 2 B09 1 812 1 B12.1 1 B15 , 1 816 1 REFRIGERATOR. SHORTY REFRIGERATOR, SHORTY REFRIGERATOR, SHORTY REMOTE REFRIGERATION TOASTER. CONVEYOR UNDERBAR BLENDER STATION FROSTER /CHILLER. GLASS /MUG /PLATE GLASSWASHER BACK BAR COOLER REMOTE REFRIGERATION ESPRESSO EQUIPMENT GRINDER CON1 15 CONVENIENCE OUTLET CON2 3 CONVENIENCE OUTLET CON2 2 CONVENIENCE OUTLET CON3 3 CONVENIENCE OUTLET POS 1 POS 2 - „ II, R) I, Ill ltt 11 E[,7 v:a r: 3' -IUD" 2' + 5' -I 3' -I 5' -a 3' -4 $4000 PANEL verifcf location ELEC. PANEL verify location -2' -2' 3 ' -2 log 1 2' 11" I a _ 11.0 1/2 14.0 1.7 16.8 2.1 0.3 1.4 20.0 9.1 14 3.2 3.2 3.2 15.0 19.4 15.0 8.2 3.5 4.0 15.0 8.0 20.0 20.0 20.0 20.0 20.0 " ELECTRICAL PLAtI J ELECTRICAL W Q. S a z LA REMARKS 11.0 1/2 120 14.4 3.0 208 1 60 X 6 -20P 21.5 1.0 4.0 120 3.0 208 5.0 208 120 120 1 60 X 5 -15P 12 W/ CORDSET 120 1 X 5 -20P 125 1 60 X 5 -20P AS9 11111.1111 O >t 11.1 sift SA la 11/0 0 i A 120 1 60 X 5 -15P 48 120 1 60 X 120 120 208 208 120 1 60 X 5 -15R 17.5 NOM GOA ENE! inalc =ET Apt ■H181 1,11100118111 B05 1 /3 120 1 60 X 5 -15P 6 6 FOOT CORD W/ PLUG PROVIDED AT LEFT REAR 806 120/208 1 60 X 7.5 ICI POIER WI MECUM (311W' MINED 1 , All NO CONIOS1S ON 12OL 809 30 15 ; M18D 1/3IP Ci196UIi MEDI 3,250wU/IIIIT32IF. 812 SUPPUED F/ 02 812.1 115/208 1 60 X 24 VERIFY 815 120 1 60 X 1/3 115 1 60 X 5 -20P 120 1 60 X 5 -15P 48 120 1 60 X 5 -15P 36 120 1 60 X 5 -15P 36 120 1 60 X 5 -15P 12 120 1 60 X 5 -15P 24 VERIFY, DATA UNE Mall 1 60 X 5 -1 SP 12 W/ COROSET 1 60 X 3 60 X 3 60 X 1 60 X 5 -15P 1 60 X 1 60 X 3 60 X OUNIT VERIFY 1 60 X 6 -30P 48 VERIFY t) --Or 0 - -F 8' -4" r: 49 POWER FROM CONTROL PANEL, NO FAN POWER FROM CONTROL PANEL NO FAN 96 OUTDOOR CONNECTION OUNIT 30 OUTDOOR CONNECTION 12 FAN ONLY; 2700 BTU LOAD 12 FAN ONLY; 2900 BTU LOAD 12 'FAN ONLY; 2900 BTU LOAD III VERIFY L. v 2' -5'- 1' ' r 3' -4* 4 -3" • /I r'•.i 1 U .. . .� NO 83 84 85 86 91 94 94.1 95 1 95.1 95.2 98 102 104 104.1 108 816 CON1 CON2 CON2 CON3 POS RtCEw CM' OR Tl/lt(w,l • FEB 0 4 2X03 pT PEOur 0 07 SHEET • INDEX Q -101 - KITCHEN PLAN Q -102 - SCHEDULES Q -103 - ELECTRICAL Q -104 - PLUMBING Q -201 - ELEVATIONS Q -202 - ELEVATIONS Q - 501 - HOOD DRAWN Q -504 -HOOD DRAWINGS MIR WPM WE MOD LIMPLO Scone 1/4" = 1' Dow 12/13/02 "Q -103 r I. Pune. PLAN 61101Nf „G„,,,•,,, A10 CONSCTIONI 1 1� I beim ..`A" " ��� """'w TI Or4 =1114. AND OAS =21 I ILL M 0 Pa I IN d M AY as -OOW 110 D 1 wooed. MNA NLIA1& &A/NI Aw WINK MMri_ TO NI s 4. wave,. �D N L MI MSTALL KL I�SMMMtY M■ MID VA�,WI LM %% •TRAM AND MM n LJ � TO POOR �VIC1 MOUZAMj P&L AST S. MO MIN C NNIOACTOR TO M*OP.417■ 4,4y N Ni AT ■ ameNT TO PROMO Oa,. PPINSION MMIMRAM AM M MAIM ICHr.iil ■�1'�Nr COMMA= TO M IR • ti T O E 4. LM �■AMI M V A■K A ROUGH-IN PLU mINO NOTES 'I. T WOO R 14kM0 Ptvi NI MILL INITA & PAIIGfI OW I/N10/4/0 MTh POOP LIMO■ MO ■ r M 4. ROMIM Gd■IINAGTIGO MILL MINIM /4. NV WALL UNINICT OIIA PM AND NM MO S ILA* MOM L L1 MOM ■!■M ICS ■Mil EVAPONATIOM MV &AMT MME k7. 11DOD MRV168 GO NINAGTi *WI NwMMM AIO MULL PM TIM WSW u ALL NOCMANICAL *VV WNAL M - ML oC• fMMCN *44.L. 1111 ADVM7p MO VITA I r P . MANI MNTN MINN MOON Gi M LOCAL WOO Wu MATE GOVM AN MACAW FOOD SERVICE EQUIPMENT PLUMBING ROUGH -IN NOTES: A. ALL PLUMBING OUTLETS AND REQUIREMENTS SHOWN ON THIS PLAN ARE THE FOR FIXTURES AND EQUIPMENT SPECIFIED AS FURNISHED BY THE KITCHEN EQUIPMENT CONTRACTOR. UNLESS OTHERWISE NOTED. FOR ANY ADDITIONAL BUILDING PLUMBING REQUIREMENTS, SEE OTHER MECHANICAL PLANS. ALL DIMENSIONS GIVEN ARE FROM COLUMN UNE INTERSECT AND /OR FINISHED WALLS. ELEVATIONS GIVEN ARE FROM FINISHED FLOORS. B. PLUMBER TO CONNECT ALL WATER ONES, GAS LINES. WASTE LINES. ETC. CONNECT INDIRECT WASTES FROM EQUIPMENT (DRAIN BOARDS, QUICK DRAINS, ICE BINS, DIPPER WELLS. ETC.) TO THE NEAREST AND MOST ACCESSIBLE FLOOR OR HUB DRAIN. DO NOT RUN WASTES SO AS TO INTERFERE WITH THE OPERATION OF BUSINESS OR FUNCTION OF EQUIPMENT. SECURE TO EQUIPMENT, WALLS OR FLOOR AS REQUIRED BY ARCHITECT OR CODE. ALL ROUGH -INS SHOWN ARE TO BE RUN INSIDE WALLS, (EXCEPT INHERE NOTED). LOCATIONS INDICATE POINT OF EXIT FROM WALLS, cED.ING OR FLOOR. C. PLUMBER TO BRANCH TO CONNECTION WHERE REQUIRED AND TO FULLY CONNECT ALL EQUIPMENT AND RUN CONDENSATE UNES FROM UNITS TO DRAINS AND THESE LINES TO BE NO SMALLER THAN THE STUB OUT OF THE FIXTURE. FOR SPECIFIC TYPE OF CONNECTION AND LOCATIONS, REFER TO THE EQUIPMENT BROCHURE & DRAWINGS. D. PLUMBER TO PROVIDE SHUT -OFF VALVES ON ALL. WATER AND GAS UNES, ALL VALVES, CUT -OFFS, TRAPS. HYDROSTATIC SHOCK ELIMINATORS, PRESSURE REGULATORS AND MATERIAL NECESSARY TO CONNECT AU. UNES UNLESS ()THERM( SPECIFIED ON THE ITEM SPECIFICATIONS. E. ALL FLOOR DRAINS ARE TO BE SET 1 /2' BFF. UNLESS OTHERWISE NOTED. DO NOT SLOPE FLOORS SO CLOSE TO DRAINS AS TO CREATE 'PITS" OR "DIPS" IN FLOOR. MINIMUM RADIUS OF SLOPE TO BE 24' FROM CENTERUNE OF DRAIN. F. PLUMBING CONTRACTOR IS REQUIRED TO FURNISH AND INSTALL AU. PLUMBING COMPONENTS NECESSARY TO PROVIDE SERVICE TO LOCATIONS AND EQUIPMENT AS SHOWN ON THIS SHEET UNLESS NOTED OTHERWISE. PLUMBING CONTRACTOR IS ALSO RESPONSIBLE FOR MAKING FINAL CONNECTIONS TO EQUIPMENT AND FITTINGS SUPPLIED AND INSTALLED BY THE FSEC. G. IF ELECTROLYSIS CONDITIONS EXIST, A DIELECTRIC COUPLING SHOULD BE USED IN FINAL PLUMBING CONNECTION TO ALL WATER COOLED EQUIPMENT. H IF HIGH MINERAL CONTENT IN THE WATER SUPPLY EXISTS, IT IS RECOMMENDED THAT A WATER SOFTENER ALTER AND /OR DEIONIZER SEPARATOR BE USED IN THE FINAL PLUMBING CONNECTIONS TO CONDENSING UNITS, STEAMERS, COFFEE MAKERS, WATER HEATERS AND SIMILAR ITEMS OF KITCHEN EQUIPMENT. J THE FSC. IS TO PROVIDE ALL FAUCETS, DRAIN OUTLET FITTINGS IN FIXTURES AND SPECIALTY ITEMS AS OUTLINED IN THE ITEM ANO GENERAL PRODUCT SPECIFICATIONS FOR EQUIPMENT IT IS PROVIDING.. K OMISSIONS AND /OR ERRORS IN SCHEDULE DO NOT RELIEVE THE PLUMBING CONTRACTOR FROM COMPLETE AND CORRECT FINAL CONNECTIONS RESPONSIBIUTY. HIS REVIEW OF EQUIPMENT BROCHURE BOOK AND DRAWINGS, WILL ASSURE CORRECTNESS OF HIS WORK. L FAILURE TO COMPLY WITH THESE NOTES COULD VOID OR CANCEL MANUFACTURERS WARRANTIES. DO NOT FAIL TO COMPLY MATH THESE NOTES IN THE AREAS THAT THEY APPLY TO. IF THERE IS DOUBT AS TO THE PROPER INTERPRETATION OR ACTION THAT IS INTENDED. CONTACT THE ARCHITECT OR OWNER'S REPRESENTATIVE IMMEDIATELY. VERIFY WITH ARCHITECT OR OWNER'S REPRESENTATIVE, FINAL EQUIPMENT REQUIREMENTS BEFORE ORDERING MATERIAL REVISIONS IN EQUIPMENT OR PERFORMANCE REQUIREMENTS MAY AFFECT THE PLUMBERS WORK. M ALL WORK RELATING TO NE INSTALLATION & HOOKUP OF THE SPECIFIED EQUIPMENT IS TO BE PERFORMED IN FULL ACCORDANCE WITH APPLICABLE CITY, COUNT, LOCAL. STATE & FEDERAL CODES & ALL OTHER GOVERNMENTAL REGULATORY REQUIREMENTS. if J J C7 C7 1 0 U NO 2 7.1 10 24 25.1 26 r27 29 31 35 35.1 37 39 40 41 44 144 51 1 56 1 60 1 62 1 69 1 70 79 81 QTY EQUIPMENT CATEGORY I EVAPORATOR COIL COOLER 1 EVAPORATOR CO IL. FREEZER 1 SMOKER I TILT SKILLET 1 FILLER. KETTLE & POT RANGE, HEAVY DUTY, GAS OVEN, COMIECTION, GAS SINK. WAND 1 FIRE SUPRESSION 1 SINK. PREP 1 FAUCET. WALL MOUNT 1 SOIL DISH TABLE WAREWASHER, RACK CONVEYOR 1 PRE - RINSE. WALL MOUNT 1 WATER HEATER, BOOSTER 2 FAUCET, WALL MOUNT 1 3 COMP. DISH SINK SINK. MOP W/FAUCET SINK. DROP-IN ESPRESSO EQUIPMENT SINK. DROP -IN COFFEE MAKER. SATELLITE SYSTEM DROP -N. WATER t ICE STATION DISPENSER. ICE,/BEVERAGE 1 DIPPERWELL ASSEMBLY ICE MAKER W/O BIN PLUMBING SYMBOLS 144-HOT WATER, OR CH-COLD WATER WASTE, DIRECT - CONNECTED UNLESS NOTED "OPEN HUB" 0- INDIRECT WASTE ® FLOOR DRAIN O FLOOR DRAIN 111TH FUNNEL 4 1-11.6 DRAIN DRAIN IN FLOOR RECESS, CONNECT TO GENERAL CONTR. DRAIN PAN FLOOR SINK WITH HALF GRATE UNLESS NOTED OTIERPVISE FLOOR SINK WITH FUNNEL GRATE GAS GAS PRESSURE RE&ULATOR/BY KEG REFRIGERATION LINE ROUTED IN WALLS FROM ITEM TO ROOF TOP RACK J 1/2 34 1/2 1/2 21 1/2 1/2 14 1/2 1/2 18 1/2 3/4 1/2 18 1/2 1/2 1/4 1/2 1/4 1/2 3/4 36 T 3/4 3/8 24 3/4 21 1/2 34 21 1/2 48 24 3/8 3/8 74 18 271 8 18 \' • i 21 18 64 36 21 21 24 1 -1/2 26 2 12 2 12 2 12 2 12 2 0 1 -1/2 26 1 -1/2 26 3/4 3/4 2 3/4 3/4 1/2 3/8 1/2 3/4 1/2 60 so 12 7 24 12 24 33 14 26 a 1/2 3/ 3/4 3/4 3' -4" 144 4.S'W.C.; MIN.. 14.5' W.C.; MAX 215 30.5 5510 55 42 P L U M B REMARKS AM-0AP TO FS AIR -OAP TO FS OWE DRAIN CAS DISCONNECT AIR -GAP TO FS 2ND ORAN IS ORAN -RINSE PAN RUN BLOW -OFF TO FLOOR DRAIN WASTE TO CODE FAUCET K -240 VERIFY. AMR -GAP TO FS VERIFY MR - GAP TO FS VERIFY AMR -GAP TO FS AIR -GAP TO FS • 4 1_ 2 N N G S C H E D U L E o N ITZ.M 2 7.1 10 24 25.1 26 27 29 31 35 35.1 37 39 40 41 44 45 46 808 2 UNDEROAR GLASS RACK 809 1 GLASSMMSHER 51 810 1 UNDEREIM SINK 56 811 1 UNDERBAR FILLERS 4t ORAMNOARDS 60 812 1 BACK BAR COOLER 62 813 1 BACK BAR COOLER 69 814 1 UNOERBAR BEVERAGE TOWER 815 1 ESPRESSO EQUIPMENT 70 FD 7 FLOOR DRAIN 79 FS 11 FLOOR SINK 81 FT1&2 2 FLOOR TROUGH 1 11 11 11 11 11 \\ I+ O QTY EQUIPMENT CATEGORY 81.1 1 OK ▪ a 81.2 1 i1LTtR. WATER 82 2 SINK. HAND 96.2 1 97 1 9B 1 99 1 100 1 101 102 1 103 1 104 106 1 B02 1 803 ' 2 6 -5 - 4' -1" 1 TABLE, HOT F000 1' 2" FIRE SUPRESSION MAKE UP MR SYSTEM REFRIGERATOR. SHORTY SALAMANDER RANGE, HEAVY DUTY, MODULAR. GAS 1 **LAWMEN BROILER. GAS REFRIGERATOR. SHORTY RANGE. HEAVY DUTY. MODULAR. GAS REFRIGERATOR, SHORTY FRYER. DEEP FAT. GAS UNDEINAR GLASS RACK UNDERGO! COIN. ICE ON UNDERBAAR FILLERS & DRAINBOARDS UNDERBAR BLENDER STATION ry_51 I 2' -4" PLUMbI/YG PLAII OPEN BUR HERS /REFRMERATED RAIL COMBO WOOLEN. GAS 1 -2" N 3/8 76 1/2 21 1/2 3/8 29 3/8 3/8 3/8 1/4 k sN I n %MAW 7.5 3/8 3 -5 3 3 -3" 29 3/8 7.5 29 3 -2" 21 1 -1/2 26 -.25 3 0 -7.5 3/4 19 1/2 31.5 3/4 150 31 REAR FEED. FRNT MANIFOLD 1 -1/2 28 1 - 1/2 14 1 -1/2 14 1 -1/2 28 1 -1/2 23 1 -1/2 27 1 -1/2 7.5 1 -1/2 18 1 -1/2 27 I1_a" 1/2 25 1/2 3/4 •1 5'-I 3' 1' -n" r -- 3/4 400 10 AIR-GAP TO FS .375 INLET t OUTLET ( SAME NT. AIR -GAP TO FS 2 2 M VERIFY GAS DISCONNECT. MECH TO SUPPLY REMOTE REFRIGERAT1ON 3/4 35 64.5 FACTORY INTERCONNECTED 1.25 180 31 FRONT MANIFOLD 3/4 35 64.5 FACTOR1f INTERCONNECTED 1.25 160 31 (FRONT MANIFOLD 3/4 220 31 0?.' o I9 6-- ;T. 3 4' -8" REMOTE REFRIGERATION REMOTE REFRIGERATION REAR FEED. FRNT MANIFOLD AIR --GAP TO FS UNIT WAS 10- CIRCUIT BEVERAGE COLA Pt,ATE. AMR -GAP TO Fs 903 AMR -GAP TO FS AIR -GAP TO FS AIR -GAP TO FS SEE SPEC (WHY RED'S.) 804 D RAIN IS WET WASTE: DECK MTD. FAUCET 810 AIR -GAP TO FS 811 20"X 1/2' I.D. LINE MAIN THROUGH ACCESS HOLE IN WALL 812 NR -GAP TO FS ` 813 B EER DRAIN CONNECTION EXITS BOTTOM REAR OF DRIP TRAY. 814 VERIFY. NR-GAP TO FS 815 FS FS NECK OF WASTE CUP ACCOIIMOE TES UP TO A 3' 01A. PIPE FT N 4 N I N 2' N N P -I0" - N ; I ELF l Of :M* , Id D wir�irYfl J 4 -5" \\ 11 -a - r -r * L N0 47 10 La 4 -I ar• L.. 4'-II" w,L- 144 SODA LINES T BELOW GRADE (VIJM'T 81111 ICl • 2 ' -3 0 D 1" 1' -3" 4' -2" \' r D c:s LO 1W" WWI y to r:11 t J I a 0 RAO • � +ilt11! 2'- N 1 -5" ■■ w C] 2' -4 "i 0- 0 8" • N ITEM NO 100 101 102 103 104 106 FINCRIVED FEB 0 4 2003 PeaNT Mire CO Astp QS - 6 co - 0 0 ›.• ccd Z .9 OS z L. * to 4et 'D ( .4` u_ a. Q-10I KITCHEN PLAN Q-202 - ELEVATIONS Q-501 - 1400D DIRAUJI Q-504 -1-1000 DRAWINGS 12/13/02 s'N" 0-104 0 t;) co <I to 0 , 1/4.c) (...) fARIIIMIMPIIIT AMP gr • 14AMD —CCNV. OVEN —6 OMER 6W (n) OVEN (26) I 0 0 —BULK CO2 (49) #1.1■1.1, • , ,,,■■••••■••1, LJ LT rACK COOKLINE ELEVATION r MECH & STORAGE —WOW. TABLE (14) D. BINS (16) — — -J BAKERS TALE S WALL BACKNG WALL 51-1ELF (5) - JU 61111 KETTLE (23) — POT FILLER (23J) SKILLET (24) (FT) EXHAUST WOOD (3•) i ! ! .1_ ; ; I 1 • LL WIR —E FLTR MACHNE (812) (Si) Li WALL I•AD (1102) 0 00 O o 0 MO Pol COCK N 140L0 (23) [—WALL B4Q� MILE r — (22) — 1 —J FILAL I3 ACKING 1 (F5) I ICE CREAM FREEZER - (80) I —DIFF'ER (ELL (19) DISHWASH —HEAT STRIPS (91) e 3 r 1 " - IDISH UP LINE 0 0 • 0 0 —PANTRY ISLAND (15) • WALL 15ACKNS rikmFTEP SINK WALL —UC COOLER (18) TRANSPORT CARTS (32) —DRAIER WARIER (11) r -DION — AND —WORK —SLICER —$W) —PREP CART OW TABLE (33) (36) 66K 1 (56) (IV (34) (36) e • —WARMER (16) SPREADER (96) WALL BACK 0 0 EQUIPMEAT LVATIO/11 SAUTE' SALAMANDER SHORTY (91) (95) (35) —HAND (82) • 0 BACK5* 1 • —PREP TABLE (85) GRILL (100) EXHAUST 14000 (94J) r COOKLINE (F5) 5ALAMANDER SHORTY (101) (102) COLD PREP LINE A/10,- 0/1 —140T FOOD TABLE (84) (F6) 1 L.- BROILER (103) • 11• —6YRUP/CUP CANTER HOLDER (34) 1 SY OP RACK (32) ESPRESSO COUNTER —PREP TABLE (83) SHORTY SPREADER FRYERS (104) (105) (101) — P eite E6INES6 mAc Gomm (56) (51) . --11L4LL BACKING —MICRO WAVE (81) MICRO SHELF (85) • uc COOLER (33) —CARVNG STATION (89) —SHELF (90) 0 WALL PAD (110J) tugua. BACKING WORK TABLE (101) HAND SINK (82) 0 • monevio cm,' OF TUKWILA FEB 0 4 2003 peqwr cern 1.# .*t. . . • . • . . r . '%V't EET • INDEX Q-001 - KITCHEN IWO Q-101 - KITCHEN PLAN Q-102 - SCHEDULES Q-103 - ELECTRICAL Q-104 - PLUNGING Q-201 - ELEVATIONS Q-202 - ELEVATIONS Q-501 - HOOD DRAWINGS Q-504 -WOOD DRAWINGS Sods 112 11 a 11_ 011 Dots 11/01/02 """ 0-201 • /4 a • r L 72a L __ 3-2" CNE WALL BACKING —11XDRK —REACH-1N —EMPLOYEE —EMPLOYEE TABLE R1EFRIGERATOR COUNT1ER LOCKERS (n) ()s) (20) (21) —SHELF (IS) '7 11F1 1 fammessisesz9 L1OJOR DISPLAY ("97C BACK I3AR LINE • rii`n BAKERS TARE BOOTLE COOLER (812) LEGEND -er 411111510■ —WALL BACKING - 1 gemeetto MINDER (16*) (OS) LIOJOR DISPLAY ; 0 _ ORDER WINDCW DETAIL BY ARCA 0 (VP REACH NMI (B13) DIE WALL WARD (W) (803) ORAN- c_ —RACK —WALK-IN (0) COOLER CD (1) WALL BACKING SERVICE COUNTER E.QUIPMEAT ELEVATIOilf JOCKEY MAIN-- --puecept —KATE BOX --- WARD STATION CIALLEIlt (1603) (NM) (CS) (806) f -ROLLING RACK (12) • El 1 FRONT 13AR LINE riThWALKIN & SMOKER ELEVATION —MAIN — 1:11614 COMP lUAGWEIR (CS) (CS) —WALK-P4 FREEZER (6) (F5) I I - - - -1 DRAIN — WAND — PLATE —Tr—IBLENDEPIt— JOCKEY WAND 6W CHILLER (0•) STATION BOX MOW leig0 (eft) (005) (1503) •■I A/16-0 —SELF (15) —WOW TABLE (14) BINS (16) (1) 0 BEVERAGE COUNTER —SMOKER DETAIL (10) LOADING MOTOR ACCESS —SWING —COFFEE —ICE/ —POP r — CaNTER BAG N 50X DOOR BREWER IIITR P. I SHELF wr.i.Ase CARBCNATOR (28) (62) (69) (10) (12) RAOC.5 RACK (14) (61-6S) DOORS _J • r r I 1.141:0Elt stams eau LSE CHASE 1 WALL SACKING \- 11EA T (19) TABLE (11) [ SELF - (18) —SWING DOOR (28) \■• %, 1 • • RECEIVE, cvr FEB 0 4 PEIE.AA 4Ir INDEX SEET • Q-001 - KITCWEN INFO Q-101 - KITCHEN PLAN Q-102 - SCI4EDULES Q-103 - ELECTRICAL Q-104 PLUM15114G Q-201 ELEVATIONS Q-202 - ELEVATIONS Q-501 - 1400C) 1,RAUJINGS Q-504 -WOOD DRAWINGS Scats Daft in" 2 - es" 11/01/02 ' Q-202 1 • SPRING AIR SYSTEMS INC. HOODS ARE BUILT IN ACCORDANCE WITH UNDERWRITERS LABORATORIES LISTING "EXHAUST HOODS WITH EXHAUST FIRE DAMPERS ", UL FILE NO. MH25786, MODEL DD; UNDERWRITERS' LABORATORIES OF CANADA LISTING, "HOODS FOR COMMERCIAL AND INSTITUTIONAL KITCHENS ", ULC FILE NO.CR1907; AND CURRENT EDITIONS OF NFPA-96 AND UNIFORM MECHANICAL CODE ITEM 30, MODEL DD- B -F -MP 14.0/4.5 ITEM 94, MODEL DD-- B -F--MP 10.75/4.5 ITEM 94.1, MODEL DD-- B -F--MP 14.0/4.5 SUPPLY DUCT COLLAR EXHAUST DUCT COLLAR C/W 1" PERIMETER FLANGE AND ARRANGEMENT "D" FIRE DAMPER HANGER ROD BY INSTALLERS REMOVABLE GREASE INSERT S/S GREASE CUP 1" FOAM INSULATION PLENUM 3" AIR SPACE TYPICAL HANGER BRACKET LOCATION TO WALL MOUNTED LIGHT SWITCH BY ELECTRICAL EXHAUST DUCT COLLAR C/W 1" PERIMETER FLANGE AND ARRANGEMENT "D" FIRE DAMPER 10.0" x 19.0" 2000 CFM 0 1.5" W.C. VARIFLOW BAFFLE 3" AIR SPACE S/S PERFORATED DISCHARGE PANELS 3.00 SUPPLY DUCT COLLARS 2 10.0" X 13.0" 800 CFM EACH 0 0.20" W.C. PLAN VIEW III �! / /I1 /IIiI /I0 /.II /I 25.75 55.00 ITEM 94 13.00 44.00 APPLIANCES 129.00 19.00 10.00 3.00 12.00 SECTION VIEW 2 2 2 i I I I 1 1 13.00 ITEM 94 PLAN VIEW 0.0 i f r 55.00 1.00 •17/32" 1.75 4 1 78.00 TYPICAL HANGER ROD BRACKET ISOMETRIC I 1 3.00 23.00 VARIFLOW BAFFLE ARRANGEMENT 4 31.75 - _. 20.50 ITEM 94.1 51.50 -L- 25.75 27.50 SUPPLY DUCT COLLARS 2 ®10.0 "X29.0" 1740 CFM EACH 0 0.20" W.C. EXHAUST DUCT COLLAR C/W 1" PERIMETER FLANGE AND ARRANGEMENT "D" FIRE DAMPER 2 0 10.0" x 20.5" 2175 CFM EACH ® 1.5" W.C. 29.00 5 i� I S I I ' 168.00 63.50 55.00 20.50 29.00 1 31.75 ---- -- r j i -+ ./A1 12 Mr MA I IINIAV MANI it 27.50 54.00 1 - UGHT 2 - MEDIUM/LIGHT 3 - MEDIUM 4 - HEAVY 5 - VERY HEAVY 3.00 12.00 3" AIR SPACE TO WALL MOUNTED LIGHT SWITCH BY ELECTRICAL TYPICAL HANGER BRACKET LOCATION EXHAUST DUCT COLLAR C/W 1" PERIMETER FLANGE AND ARRANGEMENT "D" FIRE DAMPER 10.0" x 14.0" 1550 CFM 0 1.5" W.C. SUPPLY DUCT COLLARS 2 10.0" X 10.0" 618 CFM EACH 0 0.20" W.C. if I 2 I � I 1 1 I PLAN VIEW 37.00 77.00 "Or ////,%// / / / / / / / /! / /l / /J / / / / / / /l / / / / / // 4 ��1 10.00 VARIFLOW BAFFLE ARRANGEMENT 168.00 14.00 74.00 NPFA -96 1 -3.2 CLEARANCE NOTE: HOODS. GREASE EXTRACTORS AND DUCTS SHALL HAVE A CLEARANCE OF AT LEAST: -- 18 in. (457 mm) TO COMBUSTIBLE MATERIAL - 3 in. (76 mm) TO UMITED- COMBUSTIBLE MATERIAL - 0 in. (0 mm) TO NON - COMBUSTIBLE MATERIAL. ALL WALLS SSH�OWN ARE ASSUMED NON -- COMBUSTIBLE THE RE N N G Th1 X RUST DUCT MUST INSTALL. AN NFPA -96 RATED ACCESS DOOR ABOVE THE HOOD EXHAUST DUCT COLLAR FOR ACCESS TO THE WET CHEMICAL NOZZLE PROTECTING THE EXHAUST DUCTWORK AFTER THE HOOD. TOP OF HOOD EXHAUST DUCT BY OTHERS WET CHEMICAL NOZZLE ACCESS DOOR 77.00 / =t 10.00 ITEM 30 PLAN VIEW 37.00 1 - UGHT 2 - MEDIUM /LIGHT 3 - MEDIUM 4 - HEAVY 5 - VERY HEAVY 54.00 3.00 12.00 IfIjTALL NOTE.: HOODS INSTALLED BY FOOD SEVICE CONTRACTOR DUCT WORK 13Y G.C. CRY OF lift ., F EB 04 2003 fi7 CENTS, a z d) fr- 0 Q -101 - KITCI4EN PLAN Q -102 - SCI- IEDULES Q -103 - ELECTRICAL Q -104 - PLUMBING Q -201 - ELEVATIONS Q -202 - ELEVATIONS Q -501 - NOOD RAWI Q -504 -HOOD DRAWINGS Scats D . 12/13/02 '0-501 ITEM QTY VOLUME CFM TOTAL STATIC in. W.C. REV RPM SONE HP ELECTRICAL FLA 30.1 1 3550 2 1490 21 2.0 3/60/208V 6.1 FLA ITEM QTY VOLUME CFM TOTAL STATIC in. W.C. REV RPM SONE HP ELECTRICAL FLA 95.1 ONE 4350 2.0 1095 20.7 3.0 3/60/208V 9.1 FLA MODEL ACCESSORIES B C DISCONNECT YES MOTOR STARTER YES ROOF CURB ,YES HINGE KIT ,YES 28.00 31.88 39.75 28.63 28.25 39.00 35.00 MODEL ACCESSORIES B C DISCONNECT IVES MOTOR STARTER [YES ROOF CURB DYES HINGE KIT IYES PNU185RG 28.00 31.88 39.75 28.63 28.25 MODEL A Sq. B C D E F Dia. J K L PNU185RG 28.00 31.88 39.75 28.63 28.25 39.00 35.00 27.00 22.25 MODEL A Sq. B C D E F Dia. J K L PNU245RG 34.00 39.25 44.75 30.50 31.63 44.00 41.00 33.00 28.25 43.11 55 39 12.00 ACCESS DOOR 8.40 i I TYPICAL LIFTING POINT 22.98 • COMMERCIAL KITCHEN EXHAUST FAN BUILD IN ACCORDANCE WITH THE NFPA -96, UL GREASE CONSTRUCTION, UL LISTED EXHAUST FAN DIMENSIONAL DATA r `) IN INCHES I PERIMETER ROOF CURB DIMENSIONAL DATA IN INCHES ROOF OPENING K' X K` �- K Sq. ---I Sq. --I J Sq. INSULATED INSERT FLASHING BY OTHERS NOTES: MOTOR STARTER SHIPPED LOOSE TELE LE1D-093A62G C/W LRD12 COMMERCIAL AIR MAKE UP UNIT ITEM 95.2, MODEL NO. SFA18 -IGO 38.60 3/4" GAS INLET CONTROL WIRE CONNECTION PLAN VIEW THE SUPPLY FAN MOTOR IS NOT MOUNTED ON THE FAN MOTOR PLATFORM FOR SHIPMENT. THE SUPPLY MOTOR IS SHIPPED LOOSE IN A SEPARATE BOX LOCATED IN THE SFA FAN SECTION. INSTALLING CONTRACTOR MUST INSTALL SUPPLY MOTOR WITH SHEAVE ON MOTOR PLATFORM BEFORE OPERATING. WITH START /STOP D 94.50 42.00 BUTTONS LLA Sq. - F Dia. 11 II SITTING ON CONCRETE HIGH VOLTAGE CONNECTION t 2.00 48.00 33.00 5. EF -1 FOR ITEM 30 AND 94 THESE ARE TYPICAL DRAWINGS FOR DIMENSIONAL PURPOSES ONLY AND ARE CORRECT WITHIN UNITS FOR NORMAL INSTALLATION REQUIREMENTS. THEY DO NOT NECESSARILY SHOW ACTUAL CONSTRUCTION. WARNING! DO NOT USE IN HAZARDOUS ENVIROMENTS WHERE FAN'S ELECTRICAL SYSTEM COULD PROVIDE IGNITION TO COMBUSTIBLE OR FLAMMABLE MATERIAL. UNLESS UNIT IS SPECIFICALLY BUILT FOR ENVIROMENTS. CAUTION! GUARDS MUST BE INSTALLED WHEN FAN IS WITHIN REACH OF PERSONNEL OR WITHIN SEVEN (7) FEET (2134 mm) OF WORKING LEVEL OR WHEN DEEMED ADVISABLE FOR SAFETY. ENGINEERING DATA: 1. MODEL NO.. 2. WEIGHT: 3. DESIGN: . ARRANGEMENT: . SUPPLY VOLUME: 6. STATIC PRESSURE: 7. SUPPLY FAN: 8. SUPPLY FAN MOTOR: OPEN DRIP 9. SUPPLY FAN RPM: 10. SUPPLY FILTERS: 2" PLEATED FILTERS 4 0 2" X 24" X 24 35% ASHRAE 52-76 EFFICIENT 11. GAS HEATER: MODEL NUMBER OUTPUT RATING: INPUT RATING: INLET PIPE: FUEL: FUEL PRESSURE: FUEL VOLUME: VENT: APPROVAL: MECHANICAL: ELECTRONIC: ROOMSTAT: AMBIENTSTAT INTERLOCKS: 13. REMOTE STATION: FAN ON /OFF SWITCH: SUMMER /WINTER SWITCH: 14. ELECTRICAL: FULL LOAD AMPS 15. DAMPERS: FAN ON LIGHT: RETURN AIR: 16. HEATED SUPPLY AIR DISCHARGE: 17. UNHEATED SUPPLY AIR DISCHARGE: 21. TURNDOWN PLENUM 22. ACCESSORIES 23. ACCESSORIES: 24. ACCESSORIES: CONTROL TRANSFORMER: SFA18 --IGOD 1250 LBS OUTDOOR HORIZONTAL SLEEPER MOUNTED 7120 CFM 0.70" W.C. DELHI 818 PROOF: 5.0 HP -- 3/60/208V 744 HFG400SF 300,000 BTU /HR 400,000 BTUJhr 3/4" NATURAL GAS 7" W.C. 400 SCFH GRAVITY CGA 12. TEMPERATURE CONTROL: MECHANICAL MODULATING YES N/A N A N A TO RPD11 PANEL RPD11 YES YES YES 14.0 FLA DISCONNECT SWITCH: TELE 30 AMP OUTDOOR MOTOR STARTERS & 0 /L: SHIP LOOSE TELE LE1D183A62G C/W LRD21 NO N/A FRESH AIR INLET: TYPE SCD57 - 30" X 28 36 X 16" N/A 18. DAMPER MOTOR CONTROL: BELIMO NF120 -S 19. INLET COWL WITH FILTERS YES 20. FAN ISOLATORS: RUBBER PADS YES N/A N/A N/A NOTES: 1. THE MIN MUM CLEARANCE TO COMBUSTIBLES TO THE UNIT IS 6' (150mm). HOWEVER IT IS RECOINENOED THAT THE CLEARANCE OF AT LEAST it (310mm) BE MAINTAINED D FOR SERNCE ACCESS. NO MINIMUM CLEARANCE TO COMBUSTIBLE IS GIVEN TO THE TOP OF 'ME UNIT BECAUSE THE UNIT SHOULG NOT BE MOUNTED UNDER O1Idb1ANCS OR OBSTRUCTION. MINIMA CLEARANCE TO COMBUSTIBLE TO THE BOTTOM OF THE UNIT IS 3' (7Srnm) FROM THE BOTTOM SHEET METAL CASING. 2. THE RATINGS SHORN ABOVE ARE FOR ELEVATIONS UP TO 2000 R. (O10m). FOR HIGHER ELEVATIONS THE INPUT RATING IS REDUCED AT THE RATE OF 4% FOR EACH 1000 ft. 305m) ABOVE SEA LEVEL 3. MAXIMUM TDAPMATURE RISE FOR EACH HEATER IS 100'F (31Z). 4. HEAT EXCHANGER: AIRFLOW CONTOURED TUBES DE- FORMED FROM ALUMINIZED STEEL (400 STAINLESS STEEL FOR MAKEUP PM UNIT'S), HEUACR WELDED TUBES. e BURNER: ALUMINIZED STEEL (409 STAINLESS STEEL FOR MAKEUP NR UNITS), IM1H SLOTTED OVERSIZED PORTS, UHT FREE PLOT BURNER, ENTIRE BURNER BOX SLIDES OUT FOR EASY SERVICING. IL GAS CONTROLS: 120V/1/00 POWER SUPPLY AND 2$V CONTROLS, LMT CONTROL SMUTS OFF NM BURNER TO PREVENT O1ERpEATING, SNQE STAGE INTERMITTENT lT PLOT IGNITION FOR NATURAL CAS RIM SAFETY REDUNDANT GAS VALVE 7. HORSEPOWER RA1MwG FOR THE UNIT NCU.UDES DRIVE LOSSES, INTERNAL STATIC PRESSURE (WCL UDED FURNACE, FRIERS, DAMPERS ETC.) AND THE EXTERNAL STATIC PRESSURE INCLUDES ANY RESISTANCE OMEN 1ft TO INLET NID OUTLET CONNECTIONS OF THE UNIT. S COMMERCIAL KITCHEN EXHAUST FAN BUILD IN ACCORDANCE WITH THE NFPA -96, UL GREASE CONSTRUCTION, UL LISTED EXHAUST FAN DIMENSIONAL DATA IN INCHES D 2.00" PERIMETER ROOF CURB DIMENSIONAL DATA IN INCHES ROOF OPENING K' X K' �-- x sq. -� I_ L Sq. _1 J Sq. INSULATED INSERT FLASHING BY OTHERS NOTES: MOTOR STARTER SHIPPED LOOSE TELE LE1 D- 123A62G C/W LRD14 • M o o ►9 EF -2 FOR ITEM 94.1 THESE ARE TYPICAL DRAWINGS FOR DIMENSIONAL PURPOSES ONLY AND ARE CORRECT WITHIN LIMITS FOR NORMAL INSTALLATION REQUIREMENTS. THEY DO NOT NECESSARILY SHOW ACTUAL CONSTRUCTION. WARNING! DO NOT USE IN HAZARDOUS ENVIROMENTS WHERE FAN'S ELECTRICAL SYSTEM COULD PROVIDE IGNITION TO COMBUSTIBLE OR FLAMMABLE MATERIAL UNLESS UNIT IS SPECIFICALLY BUILT FOR ENVIROMENTS. CAUTION! GUARDS MUST BE INSTALLED WHEN FAN IS WITHIN REACH OF PERSONNEL OR WITHIN SEVEN (7) FEET (2134 mm) OF WORKING LEVEL OR WHEN DEEMED ADVISABLE FOR SAFETY. 1 ,; C� c FEB 04 2003 PERMIT DER co fr- SHEET INDEX Q -101 - KITCHEN PLAN Q -102 - SCHEDULES Q-103 - ELECTRICAL Q -104 - PL If Q -201 - ELEVATIONS Q -202 - ELEVATIONS Q -501 - HOOD DRAWL Q -504 -HOOD DRAWINGS sca" NOT TO SCALE Ode 12/13/02 "Q -502 S St a CONTROL WIRING SCHEMATIC SFAEL1 FOR SFA SUPPLY UNIT MOTOR STARTER, AND BURNER CONTROL CURCUIT AND UL CERTIFIED RPD11 REMOTE CONTROL UNIT WITH SUMMER /WINTER SWITCH ELECTRICAL HARING BY GENERAL CONTRACTOR A ELECTRICAL WIRING BY THE MECHANICAL CONTRACTOR • FROM CIRCUIT RPD11 CONTROLLER TERMINAL 8, 9, 12 & 4, 120V/1/60 - 3 AMPS • RPD11 REMOTE PANEL FOR KITCHEN EXHAUST HOODS CSA CERTIFIED 15 AMPS. BREAKER FROM CIRCUIT RPD11 CONTROLLER TERMINAL 9 & 4, 120V/1/60 - 2 AMPS POWER WIRING TO SFA SUPPLY MOTOR STARTER BY GENERAL CONTACTOR'S ELECTRICIAN. 208V/3/60 - 14.0 FLA OCCUPIED / UNOCCUPIED -0 0-4 R6 RPD11 EXHAUST FAN SUPPLY FAN R6 SUMMER / MAN TER • -0 0- NOTE 1: ALL REMOTE ELECTRIAL WRING SHALL CONFORM TO ALL LOCAL AND NATIONAL CODE REQUIREMENTS R6 FROM 4 TO N FROM 12 TO 12 FROM 9 TO 9 FROM 8 TO 8 FROM 4 TO 3 FROM 9 TO Al 0 SFA SUPPLY UNIT MOTOR STARTER SUPPLIED BY SPRING AIR SYSTEMS LOCATED IN KITCHEN AREA INSTALLED BY THE GENERAL CONTRACTOR Al 7 RED 0 8 7 95 0 96 • OPERATION Rotate the OCCUPIED/UNOCCUPIED selector switch to the OCCUPIED position. The exhaust fon will turn on. The supply fan wdl turn on after a one minute delay while the fresh or damper The indirect gas fired heater is also interlocked to this controller. At the end of the cooking day turn the switch to the UNOCCUPIED position. Rotate the summer /winter selector switch to turn heater on and off at the start and end of the heating /cooling season Inspect the exhaust hood baffle filters doily. Clean when necessary. Refer to the maintenance manuals for information. In the even of the fire on the surface of the cooking equipment the supply fon is automatically shut off. POWER SUPPLY 120V/1/60 - 15 AMPS TO EXHAUST FAN EF -1 MOTOR STARTER - 2 AMPS. 1/60/120V TO EXHAUST FAN EF -2 MOTOR STARTER - 2 AMPS. 1/60/120V I INTERLOCK TO SHUNT TRIP - DRY CONTACT - 5 AMPS MAX. (SHUNT TRIP SUPPLIED BY ELECTRICAL CONTRACTOR) T wHI TE RED win FOUR (4) WIRES MAKEUP AIR UNIT SFA -100 MOTOR STARTER. MOTORIZED DAMPER AND END SWITCH AND SUMER- 120V /1/60 - 5 AMPS. TO SUPPLY UNIT SFA -IGO MAU -1 MOTOR STARTER - 2 AMPS. l/60/120V NOTE 2: MOTOR STARTERS OVERLOADS AND DISCONNECTS BY ELECTRICAL DIVISION r 0 IGNITION CONTROL ROBERTSHOW SP 845NL DISCONNECT SNATCH EEMAC3R ENCLOSURE DRY CONTACT FOR BUILDING F1RE ALARM FIRE ANUNCIATION. 5 AMPS MAXIMUM. N/O TWO (2) MARES TO THE WET CHEMICAL CONTROL HEAD. 120V/1/60 - 1AMP II BELIMO MODEL LF120 -F MOTORIZED INLET DAMPER MOTOR WITH END SWITCH GND TR PV/MV TH PV MV II GND MOM MINIM SFA-IGO UNIT CONTROL S W BL R GY P BL El IGNITOR 120V 24V LIMIT CONTROL R ofO PILOT OPERATOR MAIN OPERATOR MODULATION OPERATOR a t PIM. 24V KC. 4OVA rtmilFOIMERS fM r CONTROL WIRING SCHEMATIC FOR EXHAUST FAN MOTOR STARTERS AND UL CERTIFIED RPD11 REMOTE CONTROL UNIT A FROM CIRCUIT RPD11 CONTROLLER TERMINAL 13 & 4. 120V/1/60 — 3 AMPS POWER WIRING TO EXHAUST FAN MOTOR STARTER BY GENERAL CONTACTOR'S ELECTRICIAN. 208V/3/60 - 6.1 FLA • FROM CIRCUIT RPD11 CONTROLLER TERMINAL 13 & 4, 120V/1/60 - 3 AMPS POWER WIRING TO EXHAUST FAN MOTOR STARTER BY GENERAL CONTACTOR'S ELECTRICIAN. 208V/3/60 - 9.1 FLA 0 POWER WIRING BY GENERAL CONTRACTOR A CONTROL WIRING BY MECHANICAL CONTACTOR FROM 4 TO 3 FROM 13 TO Al A FROM 4 TO 3 FROM 13 TO Al EXHAUST FAN MOTOR STARTER SUPPLIED BY SPRING AIR SYSTEMS LOCATED IN KITCHEN AREA INSTALLED BY THE GENERAL CONTRACTOR 0 /R EXHAUST FAN MOTOR STARTER SUPPLIED BY SPRING AIR SYSTEMS LOCATED IN KITCHEN AREA INSTALLED BY THE GENERAL CONTRACTOR EXHAUST FAN #1 EXHAUST FAN DISCONNECT SNITCH EXHAUST FAN #2 EXHAUST FAN DISCONNECT SWITCH ft4 oi9 r EXHAUST MOTOR • RECEIVIEG CCTV pr norm, , FEB 0 4 2003 r*FaI IT CEtvrF N fr) L i3 N c‘ cil 04 cs Zr ( 11 ) . � z ;k ts) 44 `t V u 0 QS (0 V • — _11 �Mr SWEET INDEX Q -101 - KITCHEN PLAN Q -102 - SCHEDULES Q -103 - ELECTRICAL Q -104 - PLUMBING Q -201 - ELEVATIONS Q -202 - ELEVATIONS Q -501 - WOOD DRAWI Q -504 -HOOD DRAWINGS Scars NOT TO SCALE D. 12/13/02 50 • • HOOD ITEM NO. 30 HOOD MODEL NO. DD- B -F -MP 14.0/4.5 N) w I- 0 Z 2 SIP 78" QUICK SEAL QSA1 1N 1 FL 417 54" 42,5721 IF 1FL QJ►1 QrJ11 0 z 245 2FL; 7" J 1 36" -- (RANGE) 168" 1100 1FL 52" 417369 42.572 el 2451 2451 2FL 1 2FL plaNIESEMMEInir Tir 36" . F 1 RYPAN) CORNER PULLEY �--' 423251 IN 1FL HOOD SEAL QSA13 QUICK SEAL QSA1 W I- 0 z IL ) w H 0 Z GAS VALVE Mr 0 § D REU:ASE FLOW 1302 11 M OPOT: 423819 23-1 N X R-1/2 111 1 -1/2 0 CO2 CARTRIDGE: 101 -20 (423441) REMOTE PULL P/N 4835 11/11) a WET CHEMICAL FIRE SUPPRESSION SCHEMATIC FACTORY PRE-PIPED ITEM # 95 QUICK SEAL OSA1 23" 78" HOOD ITEM NO. 94LEFT HOOD MODEL NO. DD- B- -F--MP 10.75/4.5 1N 1FL 45" 41 72 245 W F- 0 2 423572 6 0 1 1 1 1FL 17" 60" (RANGE) 2W 2FL z L ® • CND r a H000 SEAL QSA9 1N 1FL 4 36" (GRIDDLE) FIELD PIPING 72" 1N 1F1 QUACK SEAL 77285 I- 0 Z 42 36" 2FL SALAMANDER 1N 1FL • • 2W 2FL 26" 42 1N 1FL • • • • 42372 42 572 N 1FL j J " ,.2FL .,1 24"- 12 29 ---16 X14 2 • • • • • • 36" 36" 36" (GRIDDLE)(CHARBROILER) (CHARBROILER) HOOD ITEM NO. 94RIGHT HOOD MODEL NO. DD-- B- F---MP 14.0/4.5 2W 2FL 0 0 16" 16" 22 =- ---- -- (GAS (GAS FRYER) FRYER) • 42 •7 1 11111161•D IMAM 0 1FL HOOD SEAL 05413 I M1111■■I Imo■ c AEI ////////////// 1// 1ff// ff ff!!!ff / /fl / / / / / /!ff!! / / / //. %/I QUICK SEAL CORNER PULLEY 423251 IL, LLI 0 I-- Z GAS VALVE RELEASE REGULATED ACTUATOR F� 4 0299 11 P 08 %TS:11 M DM: 423879 DM: 4 23-1 11111-1/2117-1/20 I 14.1 11X1 -1/t D CO2 CAR1RbCE: 101 -20 423441 CO2 CARIRDGE: 101 -30 423443) 2 HOSE GROW 10TS (PT/ 418511) r 0 .❑. SICLE TP* EN40SUAE 3.0 GAL FLOM POINTS: 11 P 4.30317 M/S DPW: 423879 A MEx : 79372 23 1119917 Q REMOTE PULL P/N 4835 MET CHEMICAL FIRE SUPPRESSION NOTE: 1. THE CONTRACTOR INSTALLING THE EXHAUST DUCT MUST INSTALL AN 101PA - 96 RATED ACCESS DOOR ABOVE TILE NO00 EXHAUST DUCT COLLAR FOR ACCESS TO THE WHET CHEMICAL NOZZLE PROTEC THE EXHAUST DUCTWORK AFTER THE HOOD. 2. THE REMOTE PULL STATION SHOULD BE MOUNTED AT A POINT OF EGRESS AND POSITIONED AT A HEIGHT DETERMINED BY THE AUTHORITIES I I- TOP OF HOOD HAVING JURISDICTION. 3. THE FIRE SUPPRESSION SYSTEM IS TO BE INSTALLED, INSPECTED. AND MAINTAINED IN ACCORDANCE TO NFPAI7A AND NFPA96 EXHAUST DUCT BY OTHERS MET CHEMICAL NOZZLE ACCESS DOOR 4. THE APPUANCES NOZZLES AND FUSIBLE UNK LOCATION ARE BASED ON THE APPLIANCE LAYOUT INFORMATION MADE AVAILABLE TO SPRING AIR SYSTEMS INC. THE APPUANCES AND 14E1R LOCAION MUST BE REVIEWED BEFORE APPROVING DRAWINGS. 5. THE MECHANICAL GAS VALVE IS DESIGNED TO SHUTOFF THE FLOW OF GAS TO THE APPUANCES APON ACTUATION OF THE REGULATED RELEASE ASSEMBLY, THE GAS VALVE IS SUPPLIED BY SPRING AIR SYSTEM INC. AND INSTALLED IN THE APPUANCE GAS UNE BY THE MECHANICAL CONTRACTOR. THE GAS VALVE MUST BE INSTALLED HORIZONTAL AND MUST NOT BE LOCATED UNDER THE HOOD. LEGEND 1/16' S/S CABLE 3/11 NPT FACTORY PIPE 3/B" NPT FIELD PIPE II TERMINAL DETECTOR. P/N 417366 ri SERIES DETECTOR. P/N 417369 • crr FEB 0 4 2003 PERMIT CE (.0 0 Z _Nt co C5 - (Cs (01 to 13 O u co 0 3 tt) 3 r SFEET • IICDC Q -101 - KITCHEN PLAN Q -102 - SCHEDULES Q -103 - ELECTRICAL Q -104 - PLUMBING Q -201 - ELEVATIONS Q -202 - ELEVATIONS Q -501 - HOOD DRAWL Q- 504 -HOOD DRAWINGS Scale I/2 " =1 Dots 12/13/02 '"'Q -504 • EVAPORATOR COIL. FREEZER SMOKER LT SKILLET FILM. KETTLE & POT RANGE. HEAVY DUTY. GAS SINK. PREP MATER HEATER. BOOSTER FAUCET. WALL MOUNT 3 COMP. DISH SINK SINK. MOP W /FAUCET SINK. DROP -IN SINK. DROP -0I COFFEE MAKER. SATELLITE MIEN DROP -IN. WATER & ICE STATION 1 /2 111 1AILI la 1 ® ®MII® 1-1/2 - _ - - - - ��� ____ 2 1/2 m Era -ED ��� MEE11111131 ____ 1 1/ ED ® -ED -� -_ ®I:11 - 3/4 1/2 ED ® -1E1 ® � - - -- 2 ® - - -- 2 ®� 3 / 4 1013:11111113 2 0 1/ ® ® -E1 '1 1/4 ©---r_ 3 /4 1/ ® ®•® 1 -1 S�' 1 / 4 113_-__ - -® •111 3/8 3/a ®.11111-- 1 / 2 _uz_® 3/4 MN BEI IN QM - 3/4 30.5 _ - 3/4 10 - 3 /4 ill IN En - _ CAS DISCONNECT EMI El -GAP TO FS EIII NI MI - EN El _ 2ND oRAM IS DRAIN -RINSE PAN ®11111111-- - -- 40 E11111111 11111111M RUN BLOW -OFF TO FLOOR DRAIN - _ -- TO CODE _ .... II FAUCET K -240 CIII _ IIMI_ On NI NMI ] . , NR-GP TO FS MN IN - -- So NI MIMI MI ®_-M ' -GAP TO FS D MIMI ill ell 0 = = -GAP TO FS EN 4.5'W.C., •••., 14.5' wt.; MAX 2 p EVAPORATOR COIL COOLER 81 1 ICE MAKER W/o BIN 3/6 74 1/2 99 100 101 102 005 2 908 2 BOB 1 910 1 811 1 812 1 913 1 914 1 815 1 FD 7 FS 11 FT1 81 2 SALAMANDER BROILER, GAS RANGE, HEAVY DUTY, MODULAR, GAS SALAMMDER BROILER. GAS REFRIGERATOR. SHORTY UNDERBMR BLENDER STATION UNDERSAR GLASS RACK GLAS9pA9IER UNOERBAR SINK UNOERBIAR FILLERS & ORMNEOAROS BACK B* COOLER 1/2 21 1/2 21 1 -1/2 26 1/2 31.5 1 -1/2 28 1 -1/2 14 1 -1/2 23 1 -1/2 27 1 -1/2 7.5 1 -1/2 1 16 1 -1/2 27 1/2 25 .375 INLET & OUTLET (SAME HT. NECK OF 1N ASTE CUP SATES UP TO A 3" DIA` PIPE FT EQUIPMENT CATEGORY 1. rr SYMBOL z Lai La C 1- z ^ a W ^ W W d 0 ,.. s.-. 3 z "CZ • ` 3 'CZ f--� f- ? 0 U`-' wia ON O ON Oa Ot a ' N �L c.�cn o< zcn xo z< OvI GeC ---- - - - - -- ABBRV CW HW HWC W W V GENERAL PLUMBING NOTES: 2. REFER TO ARCHITECTURAL DRAWINGS FOR ACTUAL LOCATION AND ELEVATION OF FIXTURES. PLUMBING EMARKS PLUMBING SYMBOLS LEGEND DESCRIPTION PLUMBING FIXTURES SHALL BE DESIGNED OR EQUIPPED TO MEET FOLLOWING WATER USE EFFICIENCY STANDARDS: a. WATER CLOSETS (TANK STYLE OR FLUSH VALVE). 1.6 GPF. b. URINALS. 1.0 GPF c. SHOWER HEADS & BATHROOM FAUCETS. 2.5 GPM d. LAVATORY & KITCHEN FAUCETS. 2.5 GPM SINK AND LAVATORY DRAINS SHALL BE CHROME PLATED 17 GA. BRASS TUBING BY ENGINEERED BRASS, DEARBORN OR BRASSCRAFT. PROVIDE INSULATED P -TRAP & SUPPLY COVERS 0 ALL EXPOSED P -TRAPS & SUPPLIES PER A.D.A. STANDARDS PLUMBING EQUIPMENT DETAIL NUMBER SHT. WHERE DETAIL IS DRAWN KITCHEN EQUIPMENT COLD WATER HOT WATER HOT WATER CIRCULATING WASTE (BURIED) WASTE (ABOVE GRADE) VENT FIRE SERVICE GAS PIPING CONDENSATE GATE VALVE 3. INSTALL WATER HAMMER ARRESTORS ON HOT AND COLD WATER PIPING OF EACH FIXTURE GROUP. UNITS SHALL BE EQUAL TO WADE "SHOCKSTOP ". SELECT UNIT SIZE AND LOCATION PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORD WITH PDI STANDARD WH -201. PROVIDE ACCESS PANELS AT ARRESTORS ABOVE CWB CEILINGS. 4. COLD WATER AND HOT WATER PIPING SHALL BE ROUTED FULL SIZE AS SHOWN ON PLANS WITH APPROPRIATE SIZE REDUCTION AT POINT OF CONNECTION TO FIXTURE. 5. INSTALL WATER PIPING ON WARM SIDE OF BUILDING INSULATION. 6. WHEN CONNECTING TO EXISTING BURIED WASTE PIPING, VERIFY PROPER FLOW CONDITIONS BEFORE COVERING. BURIED WASTE AND VENT PIPING SHALL BE MIN. 2" DIA. & SLOPED 1 /4 " /FT. EXCEPT WHERE OTHERWISE INDICATED. 7. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS EXCEPT IN SHOWER STALLS. CONTRACTOR SHALL INSTALL LOCKABLE ACCESS PANELS AT PRIMERS CONCEALED IN WALLS. KITCHEN EQUIPMENT CONNECTION SCHEDULE (PURCHASED BY K.E.C. & CONNECTED UNDER DIVISION 15 N QTY 106 902 003 1 8. COORDINATE VENT THROUGH ROOF (VTR) LOCATIONS WITH HVAC UNITS. MAINTAIN MIN. 10' -0" CLEARANCE. OFFSET VTR AS NECESSARY. 9. INSTALL WATER HEATERS IN ACCORD. WITH MANUFACTURERS RECOMMENDATIONS AND SET OUTPUT TEMPERATURE TO 115 DEG. F. UNLESS OTHERWISE NOTED. FOR ELEC. WATER HEATERS SET ON CONCRETE FLOORS, PROVIDE R -10 INSUL. PAD. 10 RISER DIAGRAMS & PLANS DO NOT SHOW SOME PIPING OFFSETS REQUIRED FOR STRUCTURAL CLEARANCES. EXACT ROUTING MAY VARY FROM THAT INDICATED. 11. SITE WATER PRESSURE IS 100+ PSIG PER TUKWILA WATER DEPT. 12. ROUTE CONDENSATE & INDIRECT WASTE LINES AS NOTED ON CONNECTION SCHEDULE BELOW. EQUIPMENT CATEGORY FRYER, DEEP FAT, GAS UNOERSAR GLASS RACK UNOERIMR co. MB CE BM SYMBOL WIDOW FILLERS • ORNNBOMRDS ABBRV TP GW FCO WCO GCO AFF NTS VTR AP PR K.E.C. P.O.C. SS INDICATES FLAG NOTE NUMBER (2) 2 2" INDICATES 2" PIPE SIZE INDICATES QUANTITY OF 2. 114 o-oiq CC M W M W W V 3- 3 9 W 9 W � N 04. ON OQ. ogic Zvi X0 DESCRIPTION BALL VALVE OR GAS COCK CHECK VALVE UNION TRAP PRIMER LINE GREASE LADEN WASTE FLOOR CLEANOUT WALL CLEANOUT GRADE CLEANOUT ABOVE FINISHED FLOOR NOT TO SCALE VENT THROUGH ROOF ACCESS PANEL PLUMBING RISER KITCHEN EQUIP. CONTRACTOR POINT OF CONNECTION TO EXISTING STAINLESS STEEL z ov w z � z cz O1+- z 1 -1/2 14 1 -11 /2 2626 3/4 3/4 1.25 3/4 3/4 3/4 400 10 .25 160 • z PLUMBIN G c�d REMARK MR -GAP TO FS AIR -GAP TO FS 1 0 "'r' GAS DISCONNECT, MECH 31 REAR FEED, FRNT MANIFOLD REMOTE REFRIGERATION 35 69.5 FACTOR1f INTERCONNECTED 180 31 FRONT MANIFOLD 35 69.5 FACTORY INTERCONNECTED REMOTE REFRIGERATION 31 FRONT MANIFOLD REMOTE REFRIGERATION NR -GAP TO FS TO SUPPLY ITEM NO 81.1 81.2 82 84 95 95.2 31 REM FEED. FRNT MANIFOLD 106 AIR -GAP TO FS 802 UNIT HIS 10-CIRCUIT BEVERAGE COD PLATE. NR-GAD TO FS 803 MR -GAP TO FS AIR -GAP TO FS SEE SPEC (WAY REG'S.) DRAM IS 1IET WASTE: DECK MTD. FAUCET NR --GAP TO FS 20"X 1/r 1.0. LINE DRAM THROUGH ACCESS HOLE IN (MALL NR -CAP TO FS BEER GRAM CONNECTION EXITS BOTTOM REAR OF DRIP TRAY. VEIMFY. NR -SAP TO FS 97 98 99 100 101 102 103 104 909 810 811 812 813 814 1115 FS FS PLUMBING FIXTURE SCHEDULE MARK ITEM WC -1 WATER CLOSET SEAT FLUSH VALVE WC -2 SAME AS WC -1 EXCEPT MOUNT 0 17" WIDE SIDE OF W.C. STALL. UR URINAL VALVE L -1 LAVATORY FAUCET DRAIN L -2 LAVATORY FAUCET DRAIN SS SERVICE SINK FAUCET THERMO. MIXING VALVE LB LAUNDRY BOX HB -1 FREEZE -PROOF HYDRANT EXTERIOR HB -2 HOSE BIBB YH YARD HYDRANT FD -1 FLOOR DRAIN FD -2 FLOOR DRAIN FS -1 FLOOR SINK 11H -2 WATER HEATER CP -1 CIRC. PUMP MFR: MODEL KOHLER: 4330 BEMIS: 1955 C SLOAN: "ROYAL" #111 KOHLER: K - 4989 -T SLOAN: "ROYAL" 186 -1 KOHLER: #2196 -4 CHICAGO: 2200- 4 -E12VP CHICAGO: KOHLER: 2032 CHICAGO: 895 - 320 -E3 DEARBORN BRASS: 760W FIAT: MSB -2424 FIAT: 830-M #TA -300 ACORN: 8186 ZURN: #Z- 1321 -4 -6--18 CHICAGO: #952 -318 HB -3 HOSE BIBB ZURN: FREEZE -PROOF #Z- 1325 -4 -18 ZURN: #Z- 1370 -17 -18 ZURN: Z -415 -S FD -1A FLOOR DRAINS (KITCHEN) SAME AS FD -1. ZURN: Z- 415 -S -9 Z -191 O- K --2 -33 GI -1 GREASE ROCKFORD: INTERCEPTOR #GF -2824 WH -1 WATER A.O. SMITH: HEATER PEC -52 PVT: #54P250A -MX ET -1 EXPANSION AMTROL: TANK #ST - 12C ARMSTRONG: S- 25 -3/4" DESCRIPTION WALL - MOUNT, SIPHON JET, ELONG. RIM., VIT. CHINA, 1 1 /2" TOP SPUD, WHITE. 1.6 GPF, MOUNT 0 15" RIM HEIGHT. SEE ARCH. DWGS. FOR MOUNTING HEIGHT. WHITE PLASTIC, OPEN FRONT, W/O COVER. A.F.F. INSTALL FLUSH VALVE HANDLE TOWARD WALL MOUNT, SIPHON JET, VIT. CHINA, 3/4" TOP SPUD. 1 GAL. FLUSH, WHITE, A.D.A. COMPUANT. 17" X 20 "OVAL, COUNTER TOP, SELF RIM, VIT. CHINA, 4" CTRS, WHITE. 4 1/2" SPOUT, AERATOR, SGL. LEVER HANDLE, 4" CHROME PLATE. CTRS, VANDAL RES. PERFORATED STRAINER. 20" X 18 ". WALL MOUNT, VIT. CHINA, 4" CTRS. W /CONCEALED ARM CARRIERS. GOOSENECK SPOUT, AERATOR, LEVER HANDLES 4" CTRS. PERFORATED STRAINER W /OFFSET TAILPIECE. FLOOR STYLE 24" X 24" X 10" MOLDED COMPOSITION STONE, 3" DIA. FLAT STRAINER. #E -77 -AA VINYL BUMPERGUARD, WHITE. WALL MOUNT W /BRACE, VAC. BKR., BUCKET HOOK, 3/4" HOSE THD., #832-M 30" HOSE & BRACKET. SAFE TO COLD WATER, CHROME PLATE. 9" X 10 ", 18 GA. STEEL WALL W/3/4" H & CW VALVES W/VAC. BKR. & 2" WASTE. WALL MOUNT. BRASS CONST., 3/4" HOSE MID., VAC. BKR. WHEEL HANDLE, CHROME PLATE. BRASS CONST., 3/4" HOSED END, VAC. BKR., WHEEL HANDLE. CHROME PLATE. WALL MOUNT MIXING VALVE W /BRONZE BOX W/O COVER VAC. BKR. BRASS CONST., 3/4" HOSED END, WALL CLAMP, CHROME PLATE. WHEEL HANDLE. BRONZE BOX, 3/4" HOSE END. VAC BKR., WHEEL HANDLE 24" BURY DEPTH. 1/4" DRAIN PORT IN VALVE HOUSING & BOX. 3" C.I. BODY, 5" SQ. ADJ. NICKEL BRONZE STRAINER, TRAP PRIMER TAPPING. PROVIDE TRAP PRIMER FOR ALL INSTALLATIONS EXCEPT SHOWERS. REFER TO FLOOR DETAIL FOR DRAIN CONST. & /OR COVERING. 4" C.I. BODY, 10" X 10" SQ. ADJ. NICKEL BRONZE STRAINER TRAP PRIMER TAPPING, 9" OVAL N.B. FUNNEL. DRILL OUT STRAINER BELOW FUNNEL. REFER TO FLOOR DRAIN DETAIL FOR DRAIN VARIATIONS DEPENDING ON FLOOR CONST. & /OR COVERING. 8" X 8" X 6" DP. CAST IRON CODY W /3" DRAIN. ACID RES. ENAM. COATING ON BODY & 1 /2" GRATE. UNLESS OTHERWISE NOTED ON FOOD SERVICE PLANS. REFER TO FLOOR DRAIN DETAIL FOR DRAIN VARIATIONS DEPENDING ON FLOOR CONST. & /OR COVERING. 23" X 29" W /4" OUTLET, WELDED STEEL CONST. W /ASPHALT COATING OUTSIDE & ENAMEL INSIDE, REINFORCED STEEL COVER, 40 GPM, 54 GAL.. HOLDING CAPACITY, INTEGRAL CONCRETE ANCHOR FLANGE W /INTEGRAL EXTENSION. 50 GAL. STORAGE, (2) 4500 WATT ELEMENTS (NON - SIMULTANEOUS) 240 VOLT /1 PH. 250 GAL. STORAGE. 540 GPH RECOVERY 0 100 DEG. F TEMP., RISE W /NAT. GAS, TEMP. /PRESS. GAUGES, ELEC. LOW WATER CUTOFF. SOUD STATE FLAME SAFEGUARD, DRAFT REGUALTOR, 10 YR. SERVICE POLICY 540 MBH INPUT. AIR INTAKE ASSY. & ALARM BELL. FAB. STEEL W /BUTYL DIAPHRAGM, POLYPROPYLENE LINER. ASME RATED. 2.4 GAL. ACCEPTANCE VOLUME. ET -2 EXPANSION AMTROL: FAB. STEEL W /BUTYL DIAPHRAGM, POLYPROPYLENE TANK #ST - 60V - LINER. ASME RATED. 2.4 GAL. ACCEPTANCE VOLUME 10 GPM 0 7' TDH., 1750 RPM, 1/12 HP, 115 VOLT, AU. BRONZE STAINLESS STEEL SHAFT SLEEVE. PROVIDE ELEC. TIME CLOCK EQUAL TO INTERMATIC #WH4O. NOTE: PROVIDE BID ALTERNATE PRICE FOR SENSOR FLUSH VALVES & FAUCETS FOR WC -1 & 2, UR, L -1 do L -2. WC -1 & 2 EQUAL TO SLOAN ROYAL #111ES -S, UR FLUSH VALVES EQUAL TO SLOAN ROYAL #188 -1, ES -3 & LAY. FLUSH VALVES EQUAL TO CHICAGO #550 -4. ALL COMPLETE W /TRANSFORMER, #127 POWER SUPPLY & #119 THERMOSTATIC ln VALVE FOR LAYS. • Ory r .;, FEB 0 4 ,: POINT ;;E:‘, - tams vivo. I StA C DAVID A. CLARK ARCHITECTS City of Tukwila 13900 Interurban ave. So. Tukwila, WA 98168 206- 433-0179 New Foster Golf Links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 1701 KS a.cavra.r►. GCH > 1/8/03 SI DER -BYERS 180 Nickerson, Suns #304 Seen% � Fax 206.285.1046 1rl■11r,11111 PLUMBING FIXTURE - SCHEDULE & LEGEND SOMA 1 /8"=1' -0" PI■aaalNIr P -101 • (P 5'-0" Fi AI± DOUBLE -SIDED FINISHED FLOOR ELEV: 20.00' 14.17 (VERIFY) 6 "WUP TO 6" FCO ie= 15.47 (VERIFY) 6" W ±I.5 %SL MEETING A ' MEETING B 2" W UP TO I O " (TYP OF 2) (TYP kOF 2) . 2" W II- 6" GCO 4" W RESTROOM CONNECT 6" WASTE TO SITE UTILITIES 0 ire= 12.00' UNDER DIVISION 15. • n a N CO D a PORCH 21'2" CW • DENOTES SPACE ALLOCATION FOR WET 4 DRY SPRINKLER RISERS 0 P.O.G. TO SITE UTILITIES 2I'2" DOMESTIC WATER UP 6 " FUPTO RISER SPRINKLER SYSTEM SHALL DRAIN DOWN TO FD-2. 3 "Q (TYP OF 2) O (TYP OF 6) OUTSIDE SEATING FOUNDATION PLAN - PLUMBING SCALE: ve•sito• COV'D DINING COV*D DINING L J FLAG NOTES: O 4" WASTE UP TO WATER CLOSET ABOVE. 02 FIRE SPRINKLER RISER, DETECTOR DOUBLE CHECK VALVE ASSY., & WATER MOTOR ALARM. �3 2" WASTE UP TO LAVATORY (1 1/2" ABOVE GRADE). 2" W/2 OR MORE LAVATORIES. (7±) 2" WASTE UP TO URINAL W /WALL CLEANOUT BELOW FIXTURES. US NOT USED. O 2" WASTE UP TO SINK. PROVIDE WCO BELOW COUNTERTOP. (1) WASTE UP TO FLOOR DRAIN, (SIZE NOTED) W /2" VENT. SEE DETAIL 8/P -301. O8 WATER HEATER ABOVE. SEE DETAIL 12/P -301. O COORD. EXACT LOCATION OF SITE CONNECTIONS WITH CML. ow7" City of Tukwila 10 COORD. LOCATION OF PIPING ABOVE ELCTRICAL ROOM WITH DIV. 16 13900 Interurban ave. So. PRIOR TO INSTALLATION. REQUIRED CLEARANCES FROM ELECTRICAL Tukwila, WA 98168 EQUIPMENT MUST BE MAINTAINED. 206- 433-0179 11 3" WASTE UP TO SERVICE SINK W /2" VENT. N Foster Golf links 12 WASTE UNE UP TO FLOOR CLEANOUT. SIZE NOTED. Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 COVERED PATIO W Le: 16.87 0 2% SLOPE SEE 1/4" SCALE PLAN #I/P -303. 03 -019 • ti Le: 16.43' (VERIFY) INSTALL W/ 24" MANHOLES FLUSH WI FINISHED GRADE SEE 514T. P-303. 15.93' (VERIFY) 3" SAN. SEWER LINE TO DUMPSTER AREA 6" W UP DRAIN. TO6 "GOO 18 LF. OF6 "W FEB n 4 Ionia wishes I DAVID Awn+rECrs PlR'" 1701 I*A_ Witt KS GCH DNS 1/8/03 SI DER - BYERS 180 Nickerson, Suite #304 Seattle, Washington 96109 Phone: 2062852936 Faoc 206.285.1045 NSW TM& WMa "4" 1 /8"= V-0" 4,0,4 i P -200 r • a•e -■•war FOUNDATION PLAN - PLUMBING �i� • B F G Cw ONLY K L � a 3" V L r L (TYP OF 2) (TYP OF 2) 3" 2" • 4" VTR REST ROOM L W/O FUNNEL 2"VDN 6" F 2 CW CONCEAL ALL PIPING T4IS AREA ABOVE CEILING 2 1 2" DOMESTIC WTR SERVICE FLOOR 112" W (250 MBN) (TYP OF 6) N 44 cw /_ fr N $44QjJ - - - � - MIME --- ••■• r- rr- MM. _MIIMMIIM _-- - -- ./■// - r mENDr r milEM.rr!__!r - yrrrr r>.NINI r r rONONo - �- r Jr III 112 " I 1 1 2" V (TYP) II 4" W, SEE 514T. P200 NOTP PROVIDE 2" WALL CLEANCUTS URINALS. N� EXPOSED PIPINGc'1141S'AREA. 2" v DN 44 "H4 CWDN TO MIXING VALVE SEE M -201 FOR VENT PIPE AND AIR INTAKE MINI.. r MEMO _!r! rr !•-- 4MENEDrr r_!rr O■ _ __ra.- rNII - WIIMM. •• MEMO r r EMMEN r r!_ r NININE r_-!rr 34"H4 2"V 4" W (TYP OF 2) COV'D DINING I "CW (14 FU'S) 11,4" CW ? V 2" v 2" W FLOOR PLAN - PLUMBING SCALE 1/11W-0* • J L 3 NW I12" CU) i (23 FU'S) i Its" CV I .1.111•11111- rlrrr -WOONNINI- 2" W 2" V J • 2" v d I" CW TO - �— COV'D DINING 4" V 7 — WATER HAMMER ARRESTORS 2" CW 91 _1 l48 FU'S) / �__lrr OlN r_ rNr r r r_r rr�rr_r� r r 3�4" I'NU I •r—'-- 2" CU) 4 VTR -I I 1 4" v r T '1T V 3j H 4 Cel I. CW — ,•�— 3 /4" I" CW I I I I , — 34" 3" v I1 (TYP) I I I I I --- I uR I I I 1I - L uR ". I 1 €, (k I "CW(15FU'S) 114"(IOFU'S) 2" V 2" V G I" OD rn, WATER, WASTE & VENT RISER DIAGRAM 0.201 N.T.S. (125 MBN) HOSPITALITY (120 MBN) COFFEE BAR 200 MBI-I ------ _-- --= - - - 3i-KE PIPING SECURED 4 CONCEALED OVER BEAM DINING - r MINIM _r iii n. rrr r ; FINISHED FLOOR ELEV: 20.00' w/ " 14 4 CW 3 "W 3 /4" RUC TO W14-2 8" TYPE "B" GAS VENT UP THRU ROOF W/ WEATHER CAP PER MFGR G (450 MB4) 3•G(1290MB1-1) 4" W 4" W I" CW -- ' I I I _JI COVERED PATIO 4" W Fri a a SEE (4" SCALE KITCHEN PLAN t2/P -303. 3 44" 14W 1140 TO WTR 14TR. ISO. VALVES IN MECH. RM. • MIXING vALYE EQUAL TO LEONARD $210 -F MOUNTED 60" AM ON MECH. RM. WALL ADJUST TO 115 ALSO SEE DETAIL $1/p -302. 4" FCO GAS METER MANIFOLD W/ (2) METERS= I#I 450 MB14 42 3200 MEW s liQIE GAS METER $1 PROVIDES G,45 FOR FIRE PLACE, FURNACE IF-1 4 FURNACE $F -2, UH-I GAS METER $2 PROVIDES GAS FOR KITCHEN, ALL DOMESTIC WATER HEATING, FURNACE IF -3, F -4, F-5 4 F-6 4 KITCHEN AIR MAKE -UP UNIT. WV , FEB 0 4 2003 — cg 1 arms 2/I• /I City of Tukwila 13900 Interurban ave. So. Tukwila, WA 98168 206- 433-0179 New Foster Golf Links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 Jana 1701 KS GCH 1/8/ av<vlara 180 Nickerson, Suite 004 Static Washington 98109 Phone: 2082852966 Fax 206.286.1045 FLOOR PLAN - PLUMBING .u. 1/8"=r-0" a,111aia■r P -201 er • N.T.S. T14D. ROD TO STRUCTURE PIPE HANGER SUSPENDED OR WALL STYLE INSULATION CONTINUOUS THRU HANGER. OP I N.T.S. INSULATION OVER PIPE TE 4 MARK PIPING PER SPEC. TYPICAL PIPE HANDER DETAIL INSULATION SHIELD DO NOT UNDERMINE FOOTING WITHIN THIS AREA. SECTION N.T.S. CONC. FOOTING SEE STRUCT. • STRAINERS PRESSURE GAUGE (TYR) I v --- 21 CW BY-PASS BALI. VALVE DOUBLE CHECK VALVE ASSY. EQUAL TO WATTS MODEL 001 QT - 2k2" (TYP. OF 2) NOTE: SECURE PRV D.C.VA ASSEMBLYS TO WALL W/ UNISTRUT CLAMPS. B-LINE PIPE CLAMP 1 52100 (GALV.) B-LINE STRUT 624 (GALVJ BOLT BOTH ENDS TO STUDS WI BRACKETS (TYP. OF 2 2" VENT 4" SPUD TO CARRIER (NOT SI- 1O(Lt4) SIDE DISCHARGE WADE : 310 (SEE PLANS) VERT. DISCHARGE WADE: 330 / 340 (SEE PLANS) OM. • 011111110 PRV DETAIL Pd01 N.T.S. • 21'2" 2" PRESSURE REDUCER 61 GPM 2 -I /2" CW SERVICE PRESSURE RELIEF VALVE, PIPE TO -.. 1 .- .. FLOOR DRAIN. STRAINER BLOUIDOUN VALVE (TYP) 11"4" PRESSURE REDUCER 33 GPM 21'2" WATER r I SERVICE FROM METER 31'2" STUD WALL + 4a, GWB GATE VALVE TO SERVICE STRAINER (TYP. FOR 2) (GALV.) OF 2) 1�i� ESCUTCHEON FOR BARRIER FREE WATER CLOSET INSTALLATIONS, INSTALL FLUSH VALVE HANDLE TOWARD THE "WIDE SIDE OF THE WATER CLOSET AREA AT MAX. 44" A.F.F. FINISHED WALL SEAT IF STANDARD HEIGHT IT BARRIER FREE HEIGHT NOTES I. SECURE PIPING 0 OTHER WATER CLOSETS 4 URINALS IN SIMILAR MANOR 2. CARRIER WIDTH FOR BACK TO BACK FIXTURES IS 13 ". 3. MODIFY CARRIER COUPLING (cal NO EXPENSE TO OWNER) TO FIT CHASE WIDTH. VERIFY WIDTH ON ARCH DRAWINGS. 4. DIMENSIONS 51-40WN ARE WADE MODEL 310 4 330 / 340 (4 "). VERIFY DIMENSIONS OF ALTERNATE MFGRS. FLUSH VALVE INSTALLATION DETAIL • • 5 1 2 " MIN. 2" MAX -- ACCESS PANEL FOR 5ERV ICE• —�"" COPPER ELBOW SHANK N.T.S. WALL FURRING WI INSUL �♦ CMU WALL 1� =44, UNION IN RISER 0 ELBOW 1-4OSE BIBB SHANK SHALL PENETRATE CMU WALL WALL FLANGE VACUUM BREAKER WHEEL HANDLE 3 4 " HOSE ../�— TI -1READ NOTE: ACTUAL EQUIP. CONFIG. MAY VARY. SEE PLUMBING FIXTURE SCHEDULE. BLDG. EXTERIOR WALL HOSE BIBB DETAIL • z n FULL SIZE (3 /4"MINJ ,%, VENT UP THROUGH 4 ROOF FOR INSIDE INSTALLATIONS (SEE PLANS) UNION SCREENED VENT FOR OUTSIDE INSTALLATIONS • CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH WITH TOP OF FLOOR. SEE SPEC. SECTION 15420 PARAGRAPH 2.03 . NOTE: FOR GRADE CLEANOUTS (G.C.O.) IN VERTICULAR TRAFFIC AREAS, PROVIDE ACCESS HOUSING EQUAL TO WADE 1 8300 MF -39. N.T.S. ROOF PENETRATION TURNED DOWN ELBOW WI INSECT SCREENED OPENING. TERMINATE MIN. IC-C• FROM NVAC OUTSIDE AIR INTAKE v It" C.I. BEND. C.I. WASTE LINE LENGTH TO SUIT. GAS VALVE 3 4" MEDIUM PRESS. GAS PIPING UNION ESCUTCHEON 0 CLG N.T.S. I• REDUCER AS NECESSARY N.T.S. 1 '2" b GALV. ALL -TND. SECURE TO STRUC ABOVE (TYP. OF 2) SEE SPECIFICATION FLOOR LINE ‘ N--- WASTE LINE k " BEND IF CLEANOUT OCCURS AT END OF LINE FLOOR CLEANOUT DETAIL 11'2" LOW PRESS. (8" W.CJ GAS PIPING (430 MB1.4) REDUCER AS NECESSARY NOTE: SEE GAS RISER DIAGRAM 13/P303 UNION AS NECESSARY �--- GAS PRESSURE REDUCING VALVE: FISHER MODEL $5102C, IN SIZE W/ I'2" ORFICE INLINE GAS P.R.V. DIAGRAM • -3,4 " 14 4 o GATE VALVE i I UNION (T P 1FU BAR 4 " ( DRAIN "x 'x3 /I6 1 '2" BOLT TO STRUCTURAL BLOCKING r (TYP. OF (2) 34 4 "CWDNTOLB. FLOW DIRECTION BRACKET MOUNTED WATER HEATER DETAIL c BALANCE OF PIPING SAME AS FLOOR CLEANOUT DETAIL SEEPAGE HOLES (TYP) CHROME WALLCOVER AND SCREW. INCA (GRATE PER SCHEDULE FIN. t FLOOR —\ 4 U ELD ALL JOINTS ALL AROUND. 2 AFTER FABRICATION REMOVE SHARP EDGES, WELD SLAG AND RUST. FINISH WIN ONE COAT EPDXY PRIMER AND TWO COATS GRAY EPDXY PAINT. . INSTALL BRACKET WITH PLATFORM AT HEIGHT NOTED A.F.F. COORDINATE WIN GENERAL CONTRACTOR 4 PROVIDE SEISMIC BRACING PER U.P.C. SECTION 510.5 . a CONTRACTOR SHALL VERIFY ALL DIMENSIONS WI REFERENCE TO ACTUAL WTR HTR USED. MAY EXTEND AS A WASTE OR A VENT LINE. WALL O NO- SPIGOT PIPING PLUGGED TEE WIN CLEANOUT IF PIPE EXTENDS UP. PLUGGED ELBOW W/ CLEANOUT OTHERWISE FLOOR LINE CAST -IRON PIPE. PROV IDE CLEANOUTS 0 SINKS 4 URINALS PER U.P.C- CLEANOUTS SHALL BE LOCATED SOW FIXTURE. WALL CLEANOUT DETAIL N.T.S. MD oiq NOTES: I. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS 4 FLOOR SINKS EXCEPT SHOWER DRAINS OR WI- ERE OTHERWISE NOTED. 2. SECURE PRIMER. EXPOSED IN MECH. ROOM OR JAN. VALVE CLOSET CONCEALED BEHIND ACCESS PANEL IN OTHER AREAS WHERE NOTED. 3. INSTALL ONLY "DX" STYLE FLOOR DRAINS 4 SINKS IN WOOD CONST. SECURE TO FLOOR WI S.S. SCREWS. SUPPLY LINE TO FIXTURE ACCESS PANEL FOR CONCEALED UNITS N.T.S. er SUPPORT FROM - STRICT. TEMP. PRESSURE RELIEF VALVE, PIPE TO BLDG EXTERIOR 8� PLYWOOD DRAIN PAN EQUAL TO SMITTY MFG. MEMBRANE IF APPLICABLE r _ • . 0 TRAP PRIMER LINE TO OTHER FLOOR DRAINS AS REQUIRED. I L I SUPPLY TUBE rL TRAP PRIMER DETAIL k2" BALL VALVE TRAP PRIMER ve►LvE TRAP PRIMER VALVE DISTRIBUTION UNIT 1 2" TRAP PRIMER (TP) LINES. (TYPJ • REctemm FEB4 4?1 3 Immo wives City of Tukwila 13900 Interurban ave. So. Tukwila, WA 98168 206- 433 -0179 New Foster Golf Links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 r6Stel SI DER - BYERS 180 Nickerson, Shits 6304 Sedge, INeehirglcn 96109 Phones 2062852986 Roc 206.285.1045 • PLUMBING DETAILS PLUMBING i r • i r ga l ' S P -301 • F b" INLE I.e. 11.84' I" FROM WATER HEATER - 140 F SHUT -OFF VALVE REDUCED PRESSURE BACKFLOW PREVENTER EQUAL TO WATTS MODEL #909- QT- 5-1-1UJ- FDA - r SEE PLAN ON SHT. P I1 -- FINISHED FLOOR 7 FIN. GRADE CONTACTOR TO AViJ5T TO GRADE gill= NINO e 1'4 N. T.S. APPROX. WTR. LINE SEE NOTE GROUT ALL AROUND, BOTH SIDES ---�. 9'-0" SCALE: N.T.S. WATER HAMMER ARRESTOR PRESSURE REDUC VALVE SET FOR 20 psi TEST COCK f300 TER HEATER BELOW D.W. • — PRESS. RELIEF VALVE PIPE TO F.D. I P -TRAP 24 LOCKING FRAME 4 COVER AIR 4 GAS TIGHT, 3 PLCS. LOCATE AS SHOIINJ, AT VAULT CENTERLINE 3' MAX 3'-0" I,e: 11.57 (VERIFY) STAINLESS STEEL STRAP AND 5/8" ANCHOR BOLT (TYPICAL) PRECAST UTILITY AULT CO., NC. 4464 R E S QU A ' (SE " N OTE 2) DISHWASHER / BOOSTER HEATER PIPING SCHEMATIC LEX COUPLING (TYP. OF 2) INSTALL SURFACE CLEAN -OUT 6" OUTLET NOTES= I. PRECAST CONC. BAFFLE SHALL BE HELD IN PLACE BY (2) 3 "x3 "x4s" ANGLE (4FT LONG) ATTACHED TO VAULT WALL WIN (4 EA.) ' ?" BOLTS 4 NUTS (WITH WASHERS) SPACED 14" O.C. ANGLE, FASTNERS SHALL BE STAINLESS STEEL OR GALVANIZED AND A514PI4ALT COATED. 2. PRECAST VAULT MD BAFFLE SHALL HAVE 8 "• KNOCKOUTS AT ALL PIPE OPENINGS. IF KNOCKOUTS ARE NOT PRESENT THAN 8 "• PIPE OPENINGS SHALL BE CORE- DRILLED. 3. CONNECTIONS TO CONCRETE WALLS WITH P.V.C. PIPE REQUIRE KOR -N- SEAL CONNECTOR OR A.C. x P.Y.C. BRANT ADAPTER. SEAL ALL PIPE CONNECTIPONS WITH NONSHRINK GROUT. 4. LINE -SIZED P.Y.C. PIPE SHALL BE USED THROUGHOUT. 5. FILL WITH CLEAN WATER PRIOR TO START OF SYSTEM. GREASE INTERCEPTOR INSTALLATION DETAIL PROVIDED BY KITCHEN CONTRACTOR 2 "VENT FULL SIZE INDIRECT WASTE tato - 1 910010 KM PIPE FROM GAS METER NON- HARDENING MASTIC EQUAL TO METALBESTOS PLASTIC SEALER 22 GA. GSM FLASHING 22 GA GSM THIMBLE I I/2" X 1/4" GSM GUIDE STRAP THERMOMETER TEMPJPRESS. I V RELIEF VALVE PIPE DRAIN TO FD-2. i DIELECTRIC UNION (TYP.) 3/COC4" KDRr41N WALL SLEEVE, SEE SPEC. ESCUTCHEON POLYURETHANE FOAM LUBRICATED PLUG COCK WITH LOCK -UP, SIZE FULL LINE I 8" _; ---- -- II dd. 6' DRIP LEG REMOVABLE CAP PIPING PENETRATION DETAIL N.T.& ROOF NOTES WEATHER CAP WITH BIRDSCREEN EQUAL TO METALBESTOS. 8" VENT, MAINTAIN MIN. 2" CLEARANCE TO COMBUSTIBLE STORM COLLAR 8 " DIA TYPE "B "VENT SECURE TO STRUCTURE WITH 1/? DIA BOLTS. 2" GAS CP -I 1 I'2 WW WATER HEATER DETAIL All N. T.B. TOP OF FLOOR SLAB N. T.S. I. INSTALL VENTING PER MFGRS. INSTRUCTION 2. SET WTR. HTR. OUTPUT TO 140 ° F. i / I ys" cuu - - ---- -- ".-- �'HpCF. -- -- - - - - - -� 3/4" HWC AmL I -- _ I I I I D4 r ' I "* P z ANCHOR WATER 1-EATER TO WALL W/ TWO I "x18 GA. GALV. STEEL STRAPS. SECURE TO WALL WI FOUR 3/8"x2 LAG SCREWS 4 FOUR FENDER WASHERS GAS COCK 6" DIRT LEG 4" CONCRETE HOUSEKEEPING PAD 8" TYPE "B" COMBUSTION AIR INTAKE 3. SECURE BOTH W14-3 4 ET -2 TO WALL W/ SEISMIC RESTRAINTS. 4. INSTALL ET -2 EXPANSION TANK ON WALL BRACKET SIMILAR TO THAT SHOWN FOR WH-I. SEE DETAIL I2 /P -30I. NOTE: LONG SWEEP PVC ELBOW 6.625" OUTSIDE DIA., 6" INSIDE DIA, 30" RADIUS. (ELECTRIC SUPPLY HOUSE IS SOURCE) ,(23> .0 6" PVC SLEEVE BURIED AS 51-1OWN ON PLANS. VERIFY W/ KEG. SODA SLEEVE ELBOW DETAIL EXTERIOR WALL 34" 140° HOT 4 COLD WATER PIPING IN WALL 115 TEMPERED NO? WATER TO FAUCET 7FERIMOSTAIG MIXING VALVE IN NOT VTR. SUPPLY LINE EQUAL TO LENARD MODEL t 210-F. RU (140 DEG. F) ROUGH-IN CUl ROUGH -IN HAND SINK CONNECTION DETAIL N.T.S. 1 14 4 CW SUPPLY I/2" ANGLE STOP SEE SPEC. SECTION /5450 NOTES: I. WALL MOUNTED HANDSINK SEMI, SIMILAR ARRANGEMENT FOR COUNTER -TOP SINKS 4 LAVATORIES. 2. PROVIDE INSUALATED "P -TRAP" COVERS 4 SUPPLIES 0 EXPOSED TRAPS PER A.D.A. REQUIREMENTS. 3. INSTALL MIXING VALVE ON THE FOLLOWING EQUIPMENT L -I, #29, 35, 46, 51 60, 82,B05 • • PRE -RINSE UNIT MOUNTED TO WALL CHROME ACUUM BREAKER START/STOP SWITCH CONNECTED UNDER DIVISION I6� f SOLENOID vALvE DISCONNECT-/ SUPPLIED W/ DISPOSER, CONNECT UNDER DIVISION 16 N.T.S. DISH- WASHER 111" CONNECTION W/ 2" ROUGH -IN W/ 2" VENT DISPOSER AM. I` I. ExPOSED PIPING SHALL BE CHROME PLATED OR STAINLESS STEEL 2. EXPOSED WIRING SHALL BE SEALED IN WATERPROOF CONDUIT. DISPOSER CONNECTION SCHEMATIC RECIENED CM Or rUIMPALA FEB 0 4 2003 pct lams vives I City of Tukwila 13900 Interurban ave. So. Tukwila, WA 98168 206 - 433 -0179 New Foster Golf Links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 1701 IONAMMNii KS GCH n. 1/8/03 Mnigatilk r ILiakv SIDER -BYERS 180 Nickerson, Suite 8304 Sestrs, WseNnglon 98109 Phone: 2082852988 Fax 206,285.1045 merims PLUMBING DETAILS PLUMBING • SEE SIT. P -200 FOR CONTINUATION l �d� T • • • 4" W 2 "WUPTO 1 51 T W UP TO 1 82 1 TO 2 "W UPTO 4 2 "vUP 2O3 "WUP TO In 60 1 3" W WW 2" v F5-I N. 1 1 1 I 1 • ■ • ♦ \\ NM SIND 3" W 3 "WUPTO W /2 "v ®3" W UP TO W/2"v €110 3 "WUP TO 3" FCO 3 "WUP TO FD-IA L_ FD-IA W /2 "v 4 4 , 31 111GiiIPM 2 "WUP TO 3" W 3 "WUPTOFCO 3 "WUP TO W /2 "v IA 3 "WUP TO FT W/2 "vim, 2 "WUP TO 3 "WUP TO FD-IA W /2 "v IMF • • • • •• m0 3•W LIP TO 11)1 2" v N 3" W 3 " W 3" W —�- 1 3 "WUP TO 3" KO 3 "WUPTO W/2 "v E!_ 11 ) ,/ , 3 WUP // TO 2" FCO / FD-1A • • D 3" UP TO W /2 "v � " CW DN TO kW" TO W/ 2" V 3 "WUPTO 45 1 te= 18.50' m + 's' 62 a � s E. OOP MOO • 1. 0 i Ill" 44W 1 CV " 3,4 MC 3, 4" G (MED. PRESS) _ -- - JWINNNI lin rot 4. • p ..n,i Y GAS SOLENOID VALVE PROVIDED BY HOOD MFR, CONNECTED UNDER DIVISION 15. INDETLOCK W/ FIRE SUPPRESSION SYSTEM. TYPE -I HD) SEE ITEM $ \V-I 0,114. DN TO lit" Cs ON TO mrdmi 3" G (1290 MBH) 2"v DN ®"4 " G DN TO ►+ 3 /4 " DN TO NM NI W/2"v ► : D FD -1A 1/ 4200 BI4 COO • • 1.I a 4e, 1t, 1 11 1 4"GW 3" GU/ 2"v 3 "VUP 3 "WUP TO W/ 2" V ll� III VIII+ 2" CW 4 11z" I-IW ‘k.‘ 3/4" 1 1 • '..� ____ 111 -� • ---1 1 _row —L- - •■= 140°---------- ili••- -- - - -- 000 es III 4 _- -- DN-- -TO -_ _ _ -- 'r_-_-1 19 I4 • 11' cw 4 I "HW rt a 344 "I4 BELOW GRADE r j 81 1 • I ' , 3 /4 "GUIDN 1 3" v DN 4 CONN. TO (4)2 "v 3 44 "CWTO 4 3/4• I-I 4 CW DN TO BELOW SINK BI I y� CW 4 3 4 " HWC 3,TM 14 DN TO W / 2"v 1 31 1 1 BI5 1 D BD 2" v 3 4" HWC , 3/4" HWC SEE ITEM 1 I" 1-1.0 DN _� • o 1. - IIIIi1 I .' 2 1 FT I W /3 "W .y' 3, " 3i 4 144 Cw I4 TO UN TO 1 _44_- _ _ / 2 " v • E =3�� ' !' n • CW 4 2" V ?vDN 30 VTR i_i •••• �— , I 3/ II 4 vW 42"v { COND LINES BY Div. 15 4 DN TO lAf a): r 4 TEE TO (2) 2 "v 1y2" � Mb • 11 + I LZ Y III :50t � ! r-- I 1G L-- " 1" . • I ;?�' 2" v4LVES 1.1 �- v 1 Ii4 "GDN T01 24 3 i4 "14 CW DN TO 1 MEND IMIM o3 -orb 1 25. 1 1 21 1 " HWC A (55 CA) I I 1 i CAA HB-3 VIR "H4 DN TO 14 4 CW 1 29- 1 3,TM 14 4 CW DN TO CHAS MITER 11 (450 MBH) 1 35.1 12 (2800 MBH) PROVIDE 3 4" COND. DRAIN FROM A1-U -1 TO SERV. SINK. KITCHEN AIR MAKE -UP UNIT PROVIDED BY KIT. EQUIP. SUPPLIER CONNECTED UNDER DIV. 15 PROVIDE ACCESSIBLE GAS COCK aS UNIT. FLUSH W/ GRADE . r i' .- 07/ # Ii i , /. - LOCATE MANHOLE — COYER FROM EDGE OF SIDEWALK. MY FEB 0 4 2003 F"ERMT c „IE. � f � BREAKFAST BAR AREA (N1C) \ , 4" W UP TO 4" FCO FLAG NOTES: \'Y ` 6" SODA LINE UP SEE DETAIL $6/P302 (TYP OF 2) 3 "wuPTO W /2 "v 3" W UP TO W /2 "v0 LOUNGE FINIS$IED FLOOR ELEv: 20.00 6" SODA LINES COORDINATE BURIED SODA LINE LOCATION W/ K.E.G. 3 "WUP TO 3 "WUP TO 3 "FCO W /2 "v 3 "WUP HALL SEE PLAN VIEW #2 THIS SHT. W/ 2" v 3 Au up TO ♦ 3" FCO 0 CONTRACTOR SHALL LOCATE PLUMBING ROUGH --IN FROM FOOD SERVICE DWGS. SHT'S, Q -101 THROUGH 0 -504. SET FLOOR DRAINS & FLOOR SINKS PER DWG. 0 -104. INSTALL CONDENSATE & INDIRECT DRAINS SHOWN ON THIS PLAN & NOTED ON SHT 0 -104. K1I FLOOR SINKS (AND THE FLOOR TRENCH) THAT RECEIVE CONDENSATE AND /OR INDIRECT WASTE FROM KITCHEN EQUIP. DO NOT REQUIRE TRAP PRIMERS. PRIMERS REQ'D. ON ALL FLOOR DRAINS. SEE GEN. NOTE #7 ON SHT. P -101 03 INSTALL WATER HAMMER ARRESTORS 0 LOCATIONS INDICATED. SEE SPEC. & GEN. NOTE #3 ON SHT. P -101. ® PROVIDE ACCESSABLE GAS COCKS 0 EACH PIECE OF EQUIP. SEE GAS RISER DIAGRAM. 1 1/2" GAS TO KITCHEN AIR MAKE -UP UNIT MAU. SEE RISER DIAGAM. FOUNDATION PLAN - PLUMBING SCALE: 1/4•.,• -0• GAS SOLENOID VALVE FOR EQUIP. BELOW EXHAUST HOODS. GAS PRESSURE REG. BY K.E.C., CONN. BY DN. 15 (TYPICAL). 4 2" W UP TO i 3 "WUP TO (4) 2 "VUP W /2 "v 3 " WUPTO WU/2"V0 16" FOOTING aS BLDG. PERIMETER (TYP) SEE STRUCT. OWLS. / FE CAB 1 /5 ,/,`, 1 2" v Y 3 /4 "H TO W/ 2" v PROVIDE WCO + 9" AFF / 7 - 4200 bliEMFAST BAR AREA (NI 3 44 " I - DN,- ' 01 60 I Wi 2" 3 4" Cal DN TO • W UP TO W/ WCO 1 69 1 LINE SLEEVE UP , 4 3 4" Clil DN 3 4" 14 4 CUJ UP TO 3 4° 14 4 CUJ UP TO LOUNGE 34. CW UP TO 1309 1 W UP TO FCO TO 3" FCO / TO 11 2" CUJ DN TO /I" 150. vALvES SCALE ve.rw • L--\ r Ha - 1 i ; KITCHEN PLAN - PLUMBING GAS RISER DIAGRAM SCALE: NTS 1 S t 24" AFF --/// ON TO ON TO 4 ,,7 0 e4), I ,v4,7 e 4.14- Po -94, Po DAVID k Cia ARCHITECTS MUM NINNINIS City of Tukwila 13900 Intenirban ave. So. Tukwila, WA 98168 206-433-0179 rows NCV7 Foster Golf Links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 1701 011AWNI SO KS GOCIICII) NE GCH T78/03 180 Nickerson, Suite #304 Seed., Washington 98109 Phone: 2082852988 Fax 208.285.1045 OMR T•110 PLU1VIBING DETAILS PLUMBING PINS 11011111M P-303 • FAN SCHEDULE COOLING COIL SCHEDULE MARK MAKE COOLING CAPACITY SUPPLY ELECTRICAL SP ELECTRICAL HP NOTES WGT. MAX i ESP MARK SERVES MFR: MODEL TYPE CFM INCH WC RPM (WATTS) VOLT /PH LBS SONES NOTES EF- 1 MEN'S 126 COOK: GC -160 CEILING 100 0.125 1500 (113W) 120V/1PH 15 4.0 1,2,A 1 EF -2 WOMEN'S 127 COOK: GC -160 CEILING 100 0.125 1500 (113W) 120V/1PH 15 4.0 1,2,A EF -3 RESTROOMS 115- 116 COOK: GN -860 INUNE 1,000 0.500 1050 (473W) 120V/1PH 75 6.0 2,B EF -4 CART BARN COOK: SPD- 20S10D WALL 2,685 0.250 950 1/3 120V/1PH 40 13.0 2,C EF -5 DISHWASHER i COOK: GN -740 INUNE 600 0.500 1050 . _ (473W) 120V/1 PH , 75 6.0 4,D EF -6 TYPE -1 HOOD EXHAUST FAN AND CURB PROVIDED BY KITCHEN CONTRACTOR 3 EF -7 TYPE -1 HOOD EXHAUST FAN AND CURB PROVIDED BY KITCHEN CONTRACTOR 3 1,770 1,035 0.50 I I 150.0 I i I I I I 300 1,2,3,4 NOTES: CONTROL NOTES: 1. ALUMINUM GRILLE A. TIME DELAY SWITCH WITH LIGHT CONTROL. PROVIDED BY M.C. INSTALLED BY E.C. 2. BACKDRAFT DAMPER B. SCHEDULED OPERATION, CONTROLLED BY FURNACE CONTROLLER TIME CLOCK, ALL DIV 15 3. COORDINATE W/ KITCHEN CONTRACTOR FOR DUCT C. CO SENSOR W /MANUAL OVERRIDE SWITCH. WALL SWITCH, CO SENSOR FURNISHED BY M.C. CONNECTION. AND INSTALLEDBY E.C. , MANUAL SWITCH FURNISHED AND INSTALLED BY E.C. 4. PROVIDE ROOF CAP D. INTERLOCK W/ DISHWASHER, INTERLOCK WIRING UNDER DIV 15, CORDINATE W /E.C. FOR RELAY. OR CONTACTORS GAS FURNACE SCHEDULE COOLING COIL SCHEDULE MARK MAKE COOLING CAPACITY SUPPLY ELECTRICAL HEATING ELECTRICAL OP. WT. LBS. NOTES TOTAL OSA i ESP FAN N.G. INPUT OUTPUT AFUE TEMP VOLT /PH HP MOCP (FLA) MARK MAKE MODEL CFM CFM - -, W.C. HP MBH MBH X RISE F -1 TRANE: TUX 120 1,600 480 0.50 3/4 120.0 112.0 92% 70 115/1 3/4 15 205 2,4 F -2 REZNOR: CAUA-250 3,570 1,300 0.75 2.0 250.0 200.0 $OX 50 208/3 2 7 380 1,2,3.4 F -3 REZNOR: CAUA -200 3,000 2,260 0.75 2.0 200.0 160.0 80% 50 208/3 2 7 300 1,2,3,4 F -4 REZNOR: CAUA - 150 , 1,620 975 0.50 1.0 150.0 120.0 80X 55 208/3 1 3.7 300 1,2,3.4 F -5 a REZNOR: CAUA - 150 1,770 1,035 0.50 1.0 150.0 120.0 1 80X 55 5 . 208/3 1 3.7 , 300 1,2,3,4 F -6 REZNOR: CAUA -200 3,010 2,760 0.80 2.0 _ 200.0 160.0 80% 50 208/3 2 7 300 12,3,4 * CU: CONDENSING UNIT (COOUNG ONLY), HP: HEAT PUMP UNIT • � � 1 NOTES: - 1. TUBULAR STAINLESS STEEL HEAT EXCHANGER 2. VERTICAL CONCENTRIC ADAPTER COMBUSTION AIR/VENT KIT 3. TWO STAGE GAS VALVE 4. FACTORY SUPPLIED COOLING COIL, SEE COOLING COIL SCHEDULE BELOW CONDENSING UNIT HEAT PUMP SCHEDULE *) COOLING COIL SCHEDULE MARK MAKE COOLING CAPACITY HEATING ELECTRICAL PRESSURE DROP NOTES . TOTAL MBH SENSIBLE MBH EAT DB / WB OAT , DB / WB SEER •22F OAT MBH VOLT/PH MCA CIR. AMP OP. WT. LBS. MARK MAKE MODEL CU -1 WANE TTPO48C3 47.5 33.6 80/67 95 11.30 N/A 208/3 20 30 245 0.15" C U -2 TRANE TTA090A3 92.4 70.8 80/67 95 10.30 N/A 208/3 37.1 60 322 90.2 CU -3 TRANE TTA090A3 90.2 65.5 80/67 95 10.30 N/A 208/3 37.1 60 322 42.0 CU -4 TRANE TTPO60C3 60.0 42.0 80/67 95 10.30 N/A 208/3 22 35 310 80/67 CU -5 TRANE TTP060C3 60.0 42.0 80/67 95 10.30 N/A 208/3 22 35 310 95 CU -6 TRANE TTA090A3 90.2 65.5 80/67 95 10.30 N/A 208/3 37.1 60 322 HP-7 TRANE TWA090A3 90.2 65.5 80/67 95 10.30 58.0 208/3 37.1 60 414 * CU: CONDENSING UNIT (COOUNG ONLY), HP: HEAT PUMP UNIT • DIFFUSER AND GRILLE SCHEDULE COOLING COIL SCHEDULE MARK MAKE MODEL CONDENSING UNIT AIR FLOW PRESSURE DROP COOLING CAPACITY MCD NOTES TOTAL MBH SENSIBLE MBH EAT DB / WB OAT DB / WB SEER OP. VT. LBS. CC -1 TRANE: TXC048 CU -1 1,600 0.20" 47.5 33.6 80/67 95 11.30 70 , HP CC -2 REZNOR: ACUB -090 CU -2 3,570 0.15" 92.4 70.8 80/67 95 10.30 110 VERTICAL CC -3 REZNOR: ACUA -090 CU -3 3,000 0.23" 90.2 65.5 80/67 95 10.30 105 ATTIC VENT CC -4 REZNOR: ACUA -060 CU -4 1,620 0.09" 60.0 42.0 80/67 95 10.30 83 ENAMEL CC -5 REZNOR: ACUA -060 CU -5 1,770 0.09" 60.0 42.0 80/67 95 10.30 83 24 "X24" CC -6 REZNOR: ACUA -090 CU -6 3,010 0.23" 90.2 65.5 80/67 95 10.30 105 RG -6 NOTE: SCHEDULED PERFORMANCE IS MINIMUM ACCEPTABLE PERFORMANCE WHEN MATCHED WITH THE INDICATED OUTDOOR UNIT AT THE SCHEDULED AIR FLOW RATE DIFFUSER AND GRILLE SCHEDULE ITEM MAKE MODEL DESCRIPTION SIZE MARK CEILING DIFFUSER TITUS MCD FOUR ADJ. CORES, STEEL, OBD, WHITE, FLAT FRAME SURFACE MOUNT. (BORDER 1) (BORDER 3 FOR LAY IN STYLE) 8 "X8" CD -1 10"X10" CD -2 12"X12" CD -3 14"X14" CD -4 16"X16" CD -5 CEIUNG TITUS TMS -M ROUND NECK, 360 DEG THROW 12" DIA. CD -6 . DIFFUSER X.C. , HP ALUMINUM, WHITE, ADJ. VANES ■ AHU -7 TRANE: TWE090A3 3,000 TO VARY FROM HORIZONTAL TO 0.50 1.5 90.2 65.5 80/67 VERTICAL 10.3/2.28 58.0 SUPPLY REGISTER TITUS 300RL DOUBLE DEFLECTION, STEEL, COLOR TO MATCH WALL COLOR 36 SR -1 BACK DRAFT DAMPER 24"X32" 2.50 LV -7 ATTIC VENT RUSKIN: ELF375X 4" DEEP, EXTRUDED ALUMINUM 48 "x32" RETURN , TITUS 5OF 1/2"x1/2"x1/2" ALUMINUM, WHITE 8 "X8" RG -1 GRILLES LV -9 ENAMEL 12"X12" RG -2 24"X12" RG -3 24 "X24" RG -4 48 "X24" RG -5 12 "X36" RG -6 AIR HANDLING UNIT SCHEDULE PARK SERVES MFR: SUPPLY A. COOLING HEATING ELECTRIC OP. VT. LBS. NOTES TOTAL OSA ESP FAN TOTAL SENS. EAT DB / WB OAT DB / WB EER /COP (NOTE 2) • 22F OAT MBH VOLT /PH MCA MAX. FUSE MARK MAKE MODEL CFM CFM X.C. , HP MBH MBH AHU -7 TRANE: TWE090A3 3,000 375 0.50 1.5 90.2 65.5 80/67 95 10.3/2.28 58.0 208/3 7.0 15 315 1 BACK DRAFT DAMPER 24"X32" 2.50 LV -7 ATTIC VENT RUSKIN: ELF375X 4" DEEP, EXTRUDED ALUMINUM 48 "x32" 5.30 LV -8 _ BIRD SCREEN, _ 24 "X28" _ 1.33 LV -9 r NOTES: 1. ECONOMIZER 2. EER WITH HP -7 AND RATED AT ARI CONDITIONS AND IN ACCORDANCE WITH DOE TEST PROCEDURES, COP AT 17F/15F OUTDOOR DB /WB LOUVER SCHEDULE PARK SERVES MFR: MODEL F. AREA CFM ITEM MAKE: MODEL DESCRIPTION SIZE (S.F.) MARK INTAKE RUSKIN: ELF375DX 4" DEEP, EXTRUDED ALUMINUM 75%81" 22.0 LV -1 LOUVER 36 BIRD SCREEN, 96 "x18" 5.70 LV-2 1/2 208V / 1PH 0.8 48 0 x32" 5.30 LV -3 42"X36" 5.30 LV -4 EXHAUST /REUEF RUSKIN: ELF375X 4" DEEP, EXTRUDED ALUMINUM 75"x81" 22.0 LV -5 LOUVER BIRD SCREEN, 24 "X32" 2.50 LV -6 BACK DRAFT DAMPER 24"X32" 2.50 LV -7 ATTIC VENT RUSKIN: ELF375X 4" DEEP, EXTRUDED ALUMINUM 48 "x32" 5.30 LV -8 _ BIRD SCREEN, _ 24 "X28" _ 1.33 LV -9 AIR DOOR SCHEDULE PARK SERVES MFR: MODEL WIDTH INCHES CFM AIR VELOCITY • NOZZLE FPM INSTAL. HEIGHT (FT) SOUND (1) PRESS.LEVEL ELECTRICAL WEIGHT LBS NOTES HP VOLT /PH FLA AD - 1 KITCHEN MARS: WA36 36 1,700 1,800 7 54 1/2 208V / 1PH 0.8 16 NO ELEC. HTG. NOTES: 1. SOUND PRESSURE LEVEL TO BASED ON dBA MEASURED IN FREE AIR 10 FT FROM THE NOZZLE 2. W/ 8 FT THREE CONDUCTOR CORD 3. CONTROL SWITCH UNDER DIV 16. COORDINATE W/ ELECTRICAL ELECTRIC WALL HEATER SCHEDULE MARK SERVES MFR: MODEL CAPACITY WATTS VOLT /PH NOTES EH -1 SPRINKLER ROOM MARKEL: E4003TA -RP 1,000 120V/1PH 1,2,3 EH RESTROOMS 126 MARKEL: E4003TA -RP 1,000 120V/1PH 1,2,3 EH -3 RESTROOMS 127 MARKEL: E4003TA -RP 1,000 120V/1PH 1,2,3 NOTES: 1. W /BUILT IN THERMOSTAT 2. INSTALLED BY E.C. 3. COLOR TO BE SELECTED BY ARCHITECT UNIT HEATER SCHEDULE MARK ITEM MFR: MODEL DESCRIPTION UH -1 GAS UNIT HEATER REZNOR: FE 125 ELECTRIC: 125.0 MBH N.G. INPUT 100.0 MBH OUTPUT, 1600 CFM 1/8 HP, 115V/ 1 PH a I • • ENERGY CODE NOTES I. SEE SCHEDULE FOR EQUIPMENT TYPE, CAPACITY AND EFFICIENCY. 2. PROVIDE THERMOSTAT CONTROLS CAPABLE OF A FIVE (5) DEGREE DEADBAND BETWEEN HEATING AND COOLING. 3. PROVIDE AUTOMATIC SETBACK CONTROLS WITH NIGHT SETBACK AND SEVEN (7) DIFFERENT DAY TYPES. 4. PROVIDE DAMPERS FOR OUTSIDE AIR INTAKES AND EXHAUST FANS WHICH CLOSE AUTOMATTICALLY WHEN THE SYSTEM IS OFF, EXCEPT FOR THOSE SYSTEMS WHICH OPERATE CONTINUOUSLY. 5. PROVIDE MICROPROCESSOR -BASED THERMOSTAT FOR HEAT PUMP CONTROLS. 6. PROVIDE GAS -FIRED HEATING EQUIPMENT WITH MODULATING OR STAGED CONTROL FOR ALL EQUIPMENT OVER 225 MBH. 7. PROVIDE A MEANS OF BALANCING EVERY AIR SUPPLY OUTLET AND AIR OR WATER TERMINAL DEVICE. 8. SIMULTANEOUS HEATING AND COOLING IN A ZONE IS NOT PERMITTED. 9. SEAL TRANSVERSE AND LONGITUDINAL SEAMS OF ALL DUCTWORK. IO.DUCT INSULATION: SEE SPECIFICATION SECTION 15250. II.PIPE INSULATION: SEE SPECIFICATION SECTION 15250. I2. ALL ELECTRIC MOTORS GREATER THAN 1.0 HP SHALL MEET WSEC TABLE 14-4 EFFICIENCY REQUIREMENTS. HVAC GENERAL NOTES I. MOUNT ALL SENSORS AND THERMOSTATS AT 4'-6" ABOVE FLOOR. 2. ALL DUCT DIMENSIONS SHOWN ARE CLEAR DIMENSIONS INSIDE DUCT LINER. 3. ALL FILTERS SHALL BE INSTALLED SO THEY MAY BE EASILY REMOVED AND REPLACED. 4. ROUTE CONTROL CONDUIT TO OUTDOOR CONDENSING UNITS WITH REFRIGERANT PIPING. 5. DO NO PLACE CONDENSING UNITS UNDER ROOF DRIP EDGE OR VALLEYS. 6. ROUTE CONDENSATE PIPING TO GRADE WITH REFRIGERANT PIPING. 7. AIR BALANCE ALL DIFFUSERS AND GRILLES SHOWN. 8. THERMOSTAT SENSORS SHALL HAVE INSULATED BACKING PAD FOR CMU WALL INSTALLATION AND /OR INSTALLED AT EXTERIOR WALL. 9. DUCT INSULATION: SEE SPECIFICATION SECTION 15250. Mop -01 SYMBOL • t 1 E.* AA. WOWS MECHANICAL SYMBOLS LEGEND •.1111111111111111111_ C �E L 0 R 2 3 H .111■11.1• O M SI ANIMISM S /FD FD BDD C 0 EX CX RLX RX ODD FCO WCO AFF NTS SS GSM EG CD RAG VTR AP SA RA EA ABBRV CW HW HNC W W V • w • ENERGY CODE LEGEND THE HVAC SYSTEM IS BASED ON THE FOLLOWING CRITERIA COMPONENT: ROOF "U" VALUE (BTUH /S.F. F) WALL "U" VALUE (BTUH /S.F. F) FLOOR "U" VALVUE (BTUH /S.F. F) GLASS "U" VALUE (BTUH /S.F. F) GLASS SHADE COEFFICIENT LIGHTING (WATTS /S.F.) MISC. EQUIP. (WATTS /S.F.) PEOPLE PER 100 SO. FT. COOLING INDOOR DESIGN TEMP. (F) COOLING OUTDOOR DESIGN TEMP. (F) HEATING INDOOR DESIGN TEMP. (F) HEATING OUTDOOR DESIGN TEMP. (F) DESIGN: =0.026 =0.057 *N.A. =0.35 =0.40 =I.6 =INCLUDED IN LIGHTS - =75 =85 =70 =23 • DESCRIPTION PLUMBING EQUIPMENT MECHANICAL EQUIPMENT DIFFUSER /GRILLE TYPE CFM DETAIL NUMBER SHT. WHERE DETAIL IS DRAWN FLAG NOTE COLD WATER HOT WATER HOT WATER CIRCULATING WASTE (BURIED) WASTE (ABOVE GRADE) VENT NATURAL GAS FIRE SERVICE COMPRESSED AIR CONDENSATE RA I NLEADER OVERFLOW DRAI GATE VALVE BALL VALVE OR GAS COCK CHECK VALVE UNION LINED DUCT FLEX DUCT SUPPLY DUCT RETURN OR EXHAUST DUCT VD VOLUME DAMPER MOTORIZED CONTROL DAMPER REMOTE OPERATED VOLUME DAMPER SD SMOKE DAMPER COMBINATION SMOKE /FIRE DAMPER FIRE DAMPER BACKDRAFT DAMPER FLEX CONNECTION TURNING VANES REMOVE DUCT, PIPE OR MECH. EQUIPMENT THERMOSTAT, MOUNT 0 4 A.F.F. CARBONDIOXIDE SENSOR MOUNT 0 4 A.F.F. CARBONdONOXIDE SENSOR MOUNT 0 6" A.F.F. UNLESS NOTED OTHERWISE YOUNGS MODULATOR CONTROL EXISTING CONNECT TO EXISTING RELOCATE EXISTING REMOVE EXISTING OPPOSED BLADE DAMPER FLOOR CLEANOUT WALL CLEANOUT ABOVE FINISHED FLOOR NOT TO SCALE STAINLESS STEEL GALVANIZED SHEET METAL EXHAUST GRILLE CEILING DIFFUSER RETURN AIR GRILLE VENT THROUGH ROOF ACCESS PANEL SUPPLY AIR RETURN AIR EXHAUST AIR 4`TTy OF T IKWn FEB 0 4 2003 JEffer COOL, (outs 2 /I0/0S I DAVID k CUPRIC ARCHITECTS City of Tukwila 13900 Interurban ave. So. Tukwila, WA 98168 206 -433 -0179 New Foster Golf Links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 jima 1701 1=AWP KS 01111110011D Eft GCH 1/8/03 SI DER -BYERS 180 Nickerson, Suite #304 Sege., Washington 98109 Phone: 2062852966 Faac 208285.1045 N/A 102111111111s M - 101 w111111111■■■rWilr HVAC SCHEDULES NOTES AND LEGEND 4 • I 12 DRYER VENT CAP, 12" ABOVE GRADE, PRO BACKDR4FT PROVIDE Cx AND SLEEVE FAN. 1 ELEC_ I4TR. FURNISHED BY M.C. INSTALLED BY EC. ELEC. 1-ITR. FURNISHED BY M.G. INSTALLED BY EC1 a. L NOTES: TROOt4 1TOM t N I2' -2" A.F.F. A� 4 ic.biLittle.TIoN AIR INTAKE UP PROVIDE CONCENTRIC ADAPTOR FOR BOTH INTAKE 4 VENT. UBLE -SIDED RG -3 ON WALL BOTTOM 'C IO' -6" A.F.F. 244 DN 10X6 -- COMBUS IR INT FLUE 18XIO iii111 MUM LIMN= MEM IM %I . EMEMEMN 111111111111111111111111 �� SEE ARCH. ELEVATIONS ING A -201 BELOW 20X20 DN SUPPORTED FROM WALL 16X16 DN UH -I 24X SEE INSTALL AS HIGH AS POSSIBLE SUPPORT FROM W RETAIL sro. l" VENT U THROUGH R W/LINER RG -2 I OX I O 215 -------- - - - - -- PROVIDE PROTECTIVE GUARD 10+ 0 CONDENSING UNIT 5HALL BE INSTALLED ON 4" CONCRETE PAD. CONCRETE PAD BY G.C. O DUCTWORK BELOW TRUSSES AND ROOF INSULATION, PROVIDE 1 INSUL_ PER SPECS. ® DUCTWORK BETWEEN TRUSSES AND ABOVE ROOF INSULATION, PROVIDE INSUL PER SPECS TO MEET REQUIREMENTS OF DUCTWORK AT BUILDING EXTERIOR 14x14 UP IN SOFFIT PROVIDE ON TOP, 6" BELOW CEILING FACING NE I I RG-6 I 24 OAI. ELEC. 14TR.. EH I FURNISHED BY M.C. INSTALLED BY EC. c l 8 a LCG. _2 14x14 UP IN SOFFIT PROVIDE ON TOP, 6" BELOW CEILING FACING NE I RG-6 , 7 AIR DOOR FOR FUTURE NOT IN TI41S CONTRACT SEE ENLARGED PLAN I -M30I OUTSIDE SEATING AIR DOOR FOR FUTURE NOT IN T14IS CONTRACT TYP. FOR 6 SCALE: 1/8' ■1'-0' COY'D DINING 124' I04 L- J FLOOR PLAN - HVAC AIR DOOR FOR FUTURE NOT IN THIS CONTRACT (TYP.OF 2) a 10. J • • COVD DINING IT (4 26X26 COUNTER BALANCED BACK DRAFT DAMPER MAX. PRESSURE DROP O. SEE ENLARGED KITCHEN PLAN I -M202 " 4 KITCHEN 26 DN TO REIRILLE PATIO 6X26 COUNTER BALANCED BACK DRAFT DAMPER MAX. PRESSURE DROP 0.01" G.C. TO PROVIDE ACCESS PANEL IN CEILING 24X18 RELIEF DUCT DN TO RG -4 (TYP. OF 2) I CD-2 I 210 TYP. FOR 6 (3 DI G 204 (2 EA) MD3 -01 H. ELEVATIONS A -20I T LOCATION al I I I I I I i • I I I p I I 1 I r I r I 1 I SEE ARCH. ElEVA71 DRAWING A-201 FOR EXACT LOCATIOis4 a • 1 /Th an os roo FEB 0 4 /003 I MINX 1/1./ � City of Tukwila 13900 Interurban ave. So. Tukwila, WA 98168 206- 433-0179 m New Foster Golf links Clubhouse 13500 Interurban Ave. Sa Tukwila, WA 98168 Palk 1701 mow KS .,r: GCH 1/8/03 180 Nickerson, Suite 1304 Sedge, Washington 98100 2082852966 Fax 208.285.1045 1 T1Tns FLOOR PLAN - HVAC KCAL! 1 / 8 "_ 1 ' - MINIMISM M -201 • • • • • 'g1 1i' • i , 1I E i , CO 1.- s - - - -. c_7 GOMBINATI FLUE AND CA INTAKE AP FOR F-I ii FLUB CAP FOR, UH-I C I it �FLUEC. I MIN. IO FT ( V ; BY KITCHEN u • A BY KIT N TRACT R COMBINATION FLUE AND CA INTAKE CAP FOR F -/, F -3, F -4, F AND F-6 ROOF PLAN - HVAC SCALE: vIr.r• 12x10 MAKE UP DN TO TYPE -I HOOD I6X1O I6xIO MAKE UP DN TO TYPE -I I8xIO 16+ I8x1ODNT ma al 0 DN TO HOOD 20x I6 UP TO •- Mj ..= - •.• • . � we ' – 30x10 MAKE UP DN TO TYPE -I HOOD D \ t' (4) 30x10 MAKE DN T OOF CAP FOR /W EXHAUS+ BREAKFAST BAR AREA (NIC) (Z� v . • A . n.' LOUNGE • FOR LOCATION EXHAUST DUCT UP IN CHIMNEY, COORDINATE W/ �. - r _ HOOD 14A4$ FROM TRUSSES W/ 16XIO DUCT AND I6XIO UP THROUGH ROOF CAP 115E ALL ALUMINUM DUCTWORK DE TRANSITIONS AND FLEX. CONNECTION INLET AND OUTLET ENLARGED KITCHEN PLAN - HVAC SCALE: 1/ruit-0° FLAG NOTE r MAKE UP AIR UNIT BY KITCHEN CONTRACTOR GAS FLUE BOTTOM 6IC -6" ABOVE A.F.F. 2O RELIEF DUCT (2 EA) 20X20 COUNTER BALANCED PROVIDE TRANSITION AS NECESSARY BACK DRAFT DAMPER MAX. PRESSURE DROP 0.01" • REFRIGERANT LINES SIZE PER MFR. RECOMMENDATIONS PROVIDE PVC CONDUIT FOR BURIED REFRIGERANT PIPING COORDINATE FLASHING AROUND DUCT W/ G.C. FLASHING BY G.C. 30X24 ON TRANSITION TO I6X36, CONNECT TO MAKE UP AIR UNIT MAKE UP AIR UNIT BY TOR INATE CACT LOCATION DE INSULATION CS. SUSPENDED FROM TRUSSES GREASE DUCT SHALL BE WRAPPED W/ 114R FIRE RESISTIVE ENCLOSURE. SEE DETAIL 341302 0 SCE DETAIL 3/M302. COORDINATE W/ KITCHEN CONTRACTOR FOR DUCT CONNECTION TO THE FAN AND EIOOD. PROVIDE ALL NECESSARY TRANSITIONS AND WRAPPING AT FAN CONNECTION OWNER WILL ENTERTAIN ADDITIONAL COST DUE TO LACK OF COORDINATION BETWEEN MECHANICAL AND KITCHEN CONTRACTORS • r ' . , a„C. FE B 0 4 O MAR C onus :Asia a GCH City of Tukwila 13900 Interurban ave. So. Tukwila, WA 98168 206- 433-0179 wpm New Foster Golf Links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 17 KS 1/8/03 MIVINIONS SI DER -BYERS 180 Nickerson, Suits #304 Seattle, Washington 98100 Phone: 2062852986 Fax 206285.1045 ENLARGED KITCHEN PLAN & ROOF PLAN HVAC rs NOTED Pan MEM M -202 • �� a FLUE AND COMB. AIR INTAKE PIPES UP THROUGH ROOF W/ COMBINATION VENT KIT. SEE ROOF PLAN ON M202 FOR EXACT ROOF PENETRATION LOCATION (TYP. OF 5) 18x22 BELOW ZE REF. PIPING ATIONS ( REF. PIPI UP AND 20X20 DF1 W/TRANS. T • 36X20 ( • •• COIL OUTLET 30X24 IN DOR FURNACES IFISTAL.LLD IRON SU - • -T5 SI F- 34F-6, SEE SECTI • 5". COMB. AIR AND FLUE PIPE FR NOTE: DO NOT RUN DUCTWORK OR PIPING ABOVE ELEC. PANELS TOP OF THE TRIM I" DUCT LINER (TYP.) 22X22 SUPPLY 5. COMB AIR INTAKE AND FLUE PIPE TO MECHANICAL ROOM SET FURNACE 4" CONCRETE PAD CONCRETE PAD BY G.C. N.T.S. RTN. AIR GRILLE ON WALL 1 M301 5 M301 ENLARGED PLAN 1/4" =1' -0" IIIIIIIIUIIIIIIIIII 20X20 SECTION SHEET METAL ELBOW W/ It LINER CEILING T-BAR RTN. AIR GRILLE RETURN AIR GRILLE CAP LocaInoN L_ 6 M301 TO IN WALL 111111111111, 1111111111111 SHEET METAL SCREWS. CAULK AND SEAL ALL (TYP) CONTINUOUS RUBBER IN SHEAR ISOLATION PADS 5" FLUE AND COMBUSTION AIR PIPES PIPES. MAXIMUM LENGTH 40 FT FOR F -3, F -4, F -5, AND F-6. MAXIMUM LENGTH 50 FT FOR F -2 DEDUCT 8FT FOR EACH 90 DEGREE ELBOW PROVIDE CONCENTRIC ADAPTER BELOW ROOF. SEE DETAIL 1 -M301 SEISMIC BRACING & VIBRATION ISOLATION OF FURNACE DETAIL INSULATI I" X 18 GAGE STRAP HANGERS AT 8' SPACING. (I) 110 X 2* SHEET METAL SCREWS 0 EACH TRUSS CHORD (TYPL *10X3/4 "SELF TAPPING CADMIUM PLATED SHEET METAL SCREWS TO ANCHOR STRAPS TO DUCT. ALL STRAPS TO BE TIGHT AGAINST DUCT AND SUPPORT IrEMBERS.(TYP.) e. : ".•rr •r••••••••.i`.. a iii i•Wi i .i'i .: NO POP RIVETS ALLOWED I" DUCT LINER (TYP.) 2 M301 FLEX. CONN. FLEX. CONN. 31X16 MIXED AIR UP INTO UNIT SECTION 1/4"et- DUCT STRAP HANGER DETAIL PERF. DIFFUSER PLATE 30X24 OAI. IN DORMER BEHIND N.T.S. 20X20 RETURN 7 M301 3 M301 it MIN. COMBUSTION AIR INLET CEILING DIFFUSER TYPICAL DIFFUSER 2" PVC FLUE PIPE UP THROUGH ROOF 3" PVC COMB. AIR INTAKE PIPE UP THROUG$4 ROOF SECTION 1/4"•1 — 18" MIN. SHEET METAL PLENUM WITH IN LINER CEILING T-BAR OR SURFACE MOUNT DIFFUSER FOR GWB CEILING 16X16 RETURN LW MOTORIZED DAMPER I4' CEILING II'-6" CEILI 24X24X24 PLENUM 5" DIA. COMBUSTION AIR PIPE VENT AND COMBUSTION AIR ROOF PENETRATION DETAIL NO TE HANG UNITS WITH PIPE HANGERS INTO SUPPORT TIMBER IN ROOF TRUSSES 24 GA. COMBINATION COMBUSTION AIR AND FLUE PIPE CONCENTRIC ADAPTER NSATE DRAINS TO IN VACUUM BREAKER TO ATMOSPHERE FURNACE CONDENSATE DRAIN COOLING COIL CONDENSATE DRAIN CONDENSATE DRAIN TRAP DETAIL SCALE: NONE Al b3 -OI'? Y l:FNTF CENTER SUPPLY '. PLENUM DUCT IN PLENUM 1 it � 8"MIN N.T.S. SUPPLY DUCT FLEX DUCT. CEILING T-BAR PARTITION t TRANSFER GRILLE ASSEMBLY NOTE: DO NOT RUN CONDENSATE DRAIN IN FRONT OF FURNACE. THIS WILL ALLOW ACCESS TO FURNACE COMPONEMTS AND FILTERS. COOLING COIL CABINET (TYPICAL) COOLING COIL CONNECTIONS MAC (TYPICAL) COOLING COIL CONDENSATE DRAIN CONDENSATE DRAIN TRAP WALL SIDEWALL SUPPLY GRILLE �SIDE M90/ WALL SUPPLY GRILLE N.T.S. SHEET METAL PLENUM WITH I" LINER CEILING GRILLE ., FEB 0 4 200.E Peon I ors 2/I•/os 1 DAVID A. UM ARCHITECTS awl City of Tukwila 13900 Interurban ave. So. Tukwila, WA98168 206- 433 -0179 New Foster Golf links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 Pi 1701 DRAINS Mr: KS MODE GCH 1/8/03 manslomfas SI DER - BYERS 180 Nickerson, Suits #304 Seale, Washington 96100 Phone: 2062862966 Roc 206.285.1045 SECTIONS & DETAILS - HVAC 1 /8 " =V-0" • • SEQUENCE OF OPERATION I. GAS FURNACE F —I: SEVEN—DAY PROGRAMMABLE ROOM THERMOSTAT PROVIDE STAGED HEATING, COOLING VENTILATION, AUTOMATIC CHANGEOVER, FAN CONTROL AND NIGHT SETBACK. FAN RUNS CONTINUOUSLY DURING OCCUPIED HOURS. OUTSIDE AIR DAMPER SHALL BE AT MINIMUM OUTSIDE AIR POSITION DURING OCCUPIED HOURS. GAS VALVE SHALL OPEN TO MEET 70F (ADJ.) ZONE HEATING TEMPERATURE SETPOINT, COMPRESSORS SHALL BE CYCLED TO MEET 75F (ADJ.) ZONE COOLING TEMPERATURE SET POINT. DURING UNOCCUPIED HOURS, FAN SHALL BE GENERALLY OFF AND OUTSIDE AIR DAMPERS SHALL BE CLOSED. IF THE ZONE TEMPERATURE DROPS BELOW 60F (ADJ) UNOCCUPIED SETPOINT, FAN SHALL CYLCE WITH FULL GAS HEATING TO MAINTAIN UNOCCUPIED HEATING SET POINT. FAN SHALL STOP AND SEND ALARM IF SUPPLY TEMPERATURE DROPS BELOW 40F. I I . GAS FURNACES F-2, F-3, F-4, F-5 AND F-6: SEVEN—DAY PROGRAMMABLE ROOM THERMOSTAT PROVIDE STAGED HEATING, COOLING VENTILATION, AUTOMATIC CHANGEOVER, FAN CONTROL AND NIGHT SETBACK, MODULATING VENTILATION CONTROL IN RESPONSE TO CO2 SENSORS, ECONOMIZER CONTROLS, AUTOMATIC CHANGEOVER, FAN CONTROL AND NIGHT SETBACK. DURING OCCUPIED HOURS FANS RUN CONTINUOUSLY WITH OUTSIDE AIR DAMPERS MODULATED AS DESCRIBED BELOW. WHEN SPACE CALLS FOR HEAT GAS HEATING SHALL BE STAGED TO MEET ZONE HEATING SET POINT. WHEN SPACE CALL FOR COOLING HEATING WILL BE DISABLED AND OUTDOOR CONDENSING UNITS CYCLE TO MEET ZONE COOLING SET POINT. DURING UNOCCUPIED MODE OUTSIDE AIR DAMPERS CLOSE AND FAN IS GENERALLY OFF WHEN ZONE TEMPERATURE DROPS BELOW UNOCCUPIED ZONE TEMPERATURE SET POINT FANS START AND GAS HEATING STAGED TO MEET ZONE MINIMUM TEMPERATURE. ECONOMIZER /CO2 SEQUENCE: UNITS SHALL BE EQUIPPED WITH HONEYWELL W72I5 B OR APPROVED EQUAL ENHANCED ECONOMIZER MODULE. OUTSIDE AIR AND RETURN AIR DAMPERS SHALL BE FURNISHED WITH HONEYWELL M74I5 DAMPER ACTUATORS FOR ECONOMIZER AND VENTILATION CONTROLS. OUTSIDE AIR DAMPER SHALL BE OPENED FROM 0% TO MIN. OUTSIDE AIR POSITION TO LIMIT INDOOR CO2 LEVEL AT A MAXIMUM OF 44OPPM RELATIVE TO OUTSIDE. WHEN THE OUTSIDE AIR TEMPERATURE IS BETWEEN 55 F AND 75 F AND SPACE CALL FOR HEAT THE ECONOMIZER CONTROLS SHALL OVERRIDE CO2 SEQUENCE AND OPEN OUTSIDE AIR DAMPER UP TO 100 %. CHANGEOVER FROM MECHANICAL COOLING TO ECONOMIZER SHALL BE FULLY AUTOMATIC. ECONOMIZERS SHALL BE INTERGRATED TYPE CAPABLE OF SIMULTANEOUS COMPRESSOR AND ECONOMIZER OPERATION. III. AIR HANDLING UNIT AHU -7 AND HEAT PUMP HP -7: SEVEN—DAY PROGRAMMABLE ROOM THERMOSTAT PROVIDE STAGED HEATING, COOLING VENTILATION, AUTOMATIC CHANGEOVER, FAN CONTROL AND NIGHT SETBACK. FAN RUNS CONTINUOUSLY DURING OCCUPIED HOURS. DAMPER SHALL BE AT MINIMUM OUTSIDE AIR POSITION DURING OCCUPIED HOURS. UNIT SHALL RUN IN HEATING MODE TO MEET 70F (ADJ.) ZONE HEATING TEMPERATURE SETPOINT. UNIT SHALL RUN IN COOLING MODE AND COMPRESSORS SHALL BE CYCLED TO MEET 75F (ADJ.) ZONE COOLING TEMPERATURE SET POINT. DURING UNOCCUPIED HOURS, FAN SHALL BE GENERALLY OFF AND OUTSIDE AIR DAMPERS SHALL BE CLOSED. IF THE ZONE TEMPERATURE DROPS BELOW 60F (ADJ) UNOCCUPIED SETPOINT, FAN SHALL CYLCE WITH UNIT IN HEATING MODE TO MAINTAIN UNOCCUPIED HEATING SET POINT. FAN SHALL STOP AND SEND ALARM IF SUPPLY TEMPERATURE DROPS BELOW 40F. ECONOMIZER OPERATION: OUTSIDE AIR DAMPERS SHALL BE FURNISHED WITH M7459AI001 ECONOMIZER CONTROLLERS. RETURN AIR DAMPERS SHALL BE FURNISHED WITH M84I5A ACTUATORS. ECONOMIZER CONTROLS SHALL PROVIDE 100% OUTSIDE AIR; CHANGEOVER FROM MECHANICAL COOLING TO ECONOMIZER SHALL BE FULLY AUTOMATIC. ECONOMIZERS SHALL BE INTERGRATED TYPE CAPABLE OF SIMULTANEOUS COMPRESSOR AND ECONOMIZER OPERATION. IV. EXHAUST FANS: SEE EXHAUST FAN SCHEDULE. V. KITCHEN VENTILATION SYSTEMS: SEE KITCHEN EQUIPMENT DRAWING(S) Q -503 AND KITCHEN SPECIFICATIONS. VI. MECHANICAL — ELECTRICAL COORDINATION: THE FOLLOWING WORK SHALL BE CONSIDERED TO BE UNDER DIVISION 16: A. ALL POWER WIRING FROM POWER SOURCE TO EQUIPMENT. B. CHECKING CURRENT CHARACTERISTICS AND ROTATION OF ALL MOTORS. C. FURNISHING AND INSTALLING DISCONNECT SWITCHES UNLESS SPECIFICALLY NOTED OTHERWISE. D. FURNISHING AND INSTALLING ALL STARTERS UNLESS NOTE OTHERWISE. THE FOLLOWING WORK SHALL BE CONSIDERED TO BE UNDER DIVISION 15: A. ALL TEMPERATURE, INTERLOCK, AND EQUIPMENT CONTROL WIRING, CONDUIT, AND APPURTENANCES, HIGH AND LOW VOLTAGE. B. ALL CONTROL WIRING, LINE OR LOW VOLTAGE, INCLUDING BUT NOT LIMITED TO WIRING THROUGH THE COILS OF THE MAGNETIC STARTERS AND RELAYS, AND THROUGH THE CONTACTS OF THERMOSTATS AND OTHER PILOT DEVICES, EXCEPT WHERE NOTED OTHERWISE. C. ALL CONTROL WIRING, LINE OR LOW VOLTAGE, INTERLOCK WIRING, LINE OR LOW VOLTAGE, AND NECESSARY MAGNETIC STARTERS AND RELAYS, AND OTHER DEVICES FOR KITCHEN VENTILATION SYSTEMS SHALL BE UNDER DIVISION 15. REFER TO KITCHEN DRAWINGS FOR SCOPE OF WORK. OWNER SHALL NOT ENTERTAIN ANY ADDITIONAL COSTS DUE TO THE LACK OF COORDINATION BETWEEN MECHANICAL— ELECTRICAL AND KITCHEN CONTRACTORS. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR ALL CONTROL SYSTEMS UNLESS NOTED OTHERWISE ON DRAWINGS. SEQUENCE OF OPERATION N.T.S. • 22 GA. FLASHING AT SHAFT 22 GA. S.S. INFILL PANELS TO NATO-11400D DUCT SENSOR (DAMPER OVERRIDE) O.A. SENSOR Al N.T.S. ROOF CURB FURNISHED BY KITCHEN CONTRACTOR INSTALLED BY G.G. HEAT AO L_- HONEYWELL CONTROLLER CONTROLLER 12" MIN. L Al I20v. POWER BY DIV. I6 N.T.S. AO J AO Al N\NN KITCHEN 1400D BY KITCHEN CONTRACTOR, SEE KITCHEN DRAWINGS CO2 SENSOR, VENTILATION CONTROL GREASE DUCT SEE M -202 FOR SIZE CEILING RA DAMPERS POINT OF CONNECTION FOR DIV 15 TYPE -I KITCHEN EXHAUST (TYPICAL) INDOOR SENSOR CONTROL DIAGRAM FOR FURNACES (TYP. FOR F- 2,3,4,5,6) EXHAUST FAN BY KITCHEN CONTRACTOR SM WEATHER 1400D POINT OF CONNECTION FOR DIV 15 ROOF PEAK ROOF GREASE DUCT 4FIRE WRAPPING FURNISHED AND INSTALLED BY DIV 15 SEE M -2O2 FOR SIZE 1 HR ENCLOSURE, "FYREWRAP" OR APPROVED EQUAL SEE NOTE 9 GENERAL NOTES FOR GREASE EXHAUST SYSTEM FOR KITCHEN 1. EXHAUST DUCT SHALL BE CONSTRUCTED OF NOT LESS THAN 0.055 INCH (NO. 16 MANUFACTURER'S STANDARD GAUGE) STEEL OR STAINLESS STEEL NOT LIGHTER THAN NO. 18 MANUFACTURER'S STANDARD GAUGE. 2. ALL JOINTS AND SEAMS SHALL BE MADE WITH CONTINUOUS LIQUID TIGHT WELD OR BRAZE MADE ON EXTERNAL SURFACE OF THE DUCT SYSTEM. 3. DUCT SYSTEM SHALL BE SO CONSTRUCTED AND INSTALLED THAT GREASE CANNOT BECOME POCKETED IN ANY PORTION THEREOF, AND THE SYSTEM SHALL SLOPE NOT LESS THAN 1/4 INCH PER LINEAR FOOT TOWARDS THE HOOD. WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 1 INCH PER LINEAR FOOT. 4. ANY PORTION HAVING SECTIONS INACCESSIBLE FROM THE DUCT ENTRY OR DISCHARGE SHALL BE PROVIDED ADEQUATE CLEANOUT OPENINGS. CLEANOUT OPENINGS SHALL BE EQUIPPED WITH TIGHT FITTING DOORS CONSTRUCTED OF STEEL HAVING A THICKNESS NOT LESS THAN THAT REQUIRED FOR THE DUCT. DOORS SHALL BE EQUIPPED WITH A SUBSTANTIAL METHOD OF LATCHING, SUFFICIENT TO HOLD THE DUCT TIGHTLY CLOSED. CLEANOUTS SHALL BE INSTALLED EVERY 20 FEET AND EVERY CHANGE IN DIRECTION AS A MINIMUM. 5. DUCT SYSTEM SHALL BE CLOSED IN TWO HOUR FIRE RESISTIVE CONSTRUCTION. THE DUCT ENCLOSURE SHALL BE SEALED AROUND THE DUCT AT THE POINT OF PENETRATION AND VENTED TO THE EXTERIOR THROUGH WEATHER PROTECTED OPENINGS. 6. DUCT SYSTEM SHALL BE SIZED FOR A MINIMUM VELOCITY OF 1500 FEET PER MINUTE AND MAXIMUM VELOCITY OF 2500 FEET PER MINUTE. 7. DUCT SYSTEM SHALL NOT CONTAIN FIRE DAMPERS, BALANCING DAMPERS OR TURNING VANES. 8. WHERE REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION, DUCT SYSTEM SHALL BE FIRE SPRINKLERED. 9. ALL EXHAUST DUCT SHALL BE WRAPPED FROM THE POINT IT PENETRATES THE CEILING UP TO ROOF PENETRATION. WRAPPING SHALL MEET UMC. WRAPPING SHALL BE "FYREWRAP" OR APPROVED EQUAL WITH UL LISTINGS. PROVIDE ACCESS PANELS ON WRAPPING AT EACH DIRECTION CHANGE AND WHERE THERE IS AN ACCESS PANEL ON DUCT. • T • k• • 101 2/16/04 1 DAVID A. CLARK AR , Pt, City of Tukwila 13900 Interurban ave. So. Tukwila, WA 98168 206- 433-0179 New Foster Golf Links Clubhouse 13500 Interurban Ave. So. Tukwila, WA 98168 yna 1701 Illh KS ONO= sir GCH 1/8/03 1111111110 Nit 1111111071/1" XILIIILS77 SAL INILWAIWIS 111110111111111111MMI h. SI DER - BYERS 180 Nickerson, Suits *304 Seale, Wotan 98109 Phone: 208.2852988 Fax 206.285.1045 ![Ili N.T.S. NM MOM M -302 DETAILS, CONTROLS SEQUENCE OF OP. HVAC _1