Loading...
HomeMy WebLinkAboutPermit M03-079 - RREEF MANAGEMENT - VACANT SPACE• RREEF (VACANT SPACE) 817 INDUSTRY DRIVE M03-079 z 11- uj CC 2 = 0 • o • uJI •co co ILI CO u. uj 0 D. a Z 0 LLI D O (1) • H. LU uj I 0 I- LL P. — 0 , z ud co P 0 Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 z Parcel No.: 2523049034 Permit Number: M03 -079 z Address: 817 INDUSTRY DR TUKW Issue Date: 05/30/2003 ce Suite No: Permit Expires On: 11/26/2003 6 v UO co o W= co ii. w Owner: g Name: CALWEST INDUSTRIAL PROP Phone: ' 4( Address: C/O DELOITTE & TOUCHE LLP, 2235 FARADAY AVE #O Si2 0 w Contact Person: z H Name: TOM REDDY Phone: 206 - 361 -0071 z O 0 Address: PO BOX 33370, SEATTLE WA I tu m p Contractor: U co Name: PRO STAFF MECHANICAL INC Phone: 206- 361 -0071 0 1- Address: PO BOX 33370, SEATTLE WA w w Contractor License No: PROSTMI072NG Expiration Date:06 /30/2004 H H u- .z w U= O F z Tenant: Name: RREEF (VACANT SPACE) Address: 817 INDUSTRY DR, TUKWILA WA DESCRIPTION OF WORK: ADD (1) NEW 2 -TON GAS /ELECTRIC A/C UNIT ON ROOF COMPLETE WITH NEW DUCT DISTRIBUTION, DIFFUSERS AND PROGRAMABLE THERMOSTATS. Value of Construction: $4,395.00 Type of Fire Protection: Permit Center Authorized Signature: 2ebp ` MECHANICAL PERMIT Fees Collected: $47.88 Uniform Mechnical Code Edition: 1997 A4-eX-Ce-C Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the 'erformance of work. I am authorized to sign and obtain this mechanical permit. s 1s0 (o Signature: ( ) Y " ' Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M03 -079 Printed: 05 -30 -2003 Parcel No.: 2523049034 Address: 817 INDUSTRY DR TUKW Suite No: Tenant: RREEF (VACANT SPACE) 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835- 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 7: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 8: Manufacturers installation instructions required on site for the building inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name : v doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS M03 -079 Permit Number: M03 -079 Status: ISSUED Applied Date: 05/22/2003 Issue Date: 05/30/2003 Date: 5- f° Printed: 05 -30 -2003 z ~ w U J H N u w 0 2 u. ? - = w � w ~ U o - 0 I— w w O . .Z w U - . 0 Site Address: Tenant Name: Property Owners Name: R fU Mailing Address: 57.A1 13/..vt7, Name: T0 E-Mail Address: Company Name: Mailing Address: Contact Person: E-Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E-Mail Address: Company Name: Mailing Address: t4 /' kapplicationapermit application (1.2003) 112003 --- CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** g (7 .i.p./12.4s7-0-q ( NONE AT T1415 "Timele Mailing Address: Po 170 c- 33T7 g Ned/100T CAI 1. Co iNel **An original or notarized copy of current Washington Contact Person: E-Mail Address: Page 1 King Co Assessor's Tax No.: 2 103 Lf. o ) Suite Number: gi 7 Floor: 1 City Day Telephone: SE - F)rfLe City Fax Number: New Tenant: J .... Yes ..No WA State State Zip c.) 3a( o/ 1/0 1 981 State Zip (2c)(0) S,) - og-zi I.iTRA INFoRMATio Zip City Day Telephone: Fax Number: Expiration Date: State Contractor License must be presented at the time of permit issuance** ::,.:ARCHITECTOERECORP;4640', Ci • - wet stampe y..-.rchttec of Record.....';' State Zip City Day Telephone: Fax Number: , . ENGINEER OVRECORD 7 -Au plans must be wet stamped by Engineer of Record State Zip City Day Telephone: Fax Number: BUILDING PERMIT ;INFORMATION : — 2064431 =3670 Valuation of Project (contractor's bid price): $ Will there be new rack storage? ❑...Yes ❑ .. No If "yes ", see Handout No. Existing Building Valuation: $ Scope of Work (please provide detailed information): for requirements. Provide All Building Areas in Square Footage Below 1" Floor 2'° Floor. 3"'• Fl oor ' Floors thru Basement Accessory . Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Existing Interior Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq 11): Floor area of principal dwelling: Floor area for accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ .. Sprinklers ❑...Automatic Fire Alarm ❑...None 0.. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑...No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. Water ❑ .. City of Tukwila Water District ❑ .. Water District 11125 ❑... Highline Water District ❑...City of Renton Water District Sewer ❑ .. City of Tukwila Sewer District ❑ .. Val Vue Sewer District ❑...City of Renton Sewer District ❑...City of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) tapplicationayxnnit application (1.2003) Page 2 .....��. .....,2. ..... __.. . ti...I .3 :.�� .ii...r�r ..............ii; •..- .- _,.�tw..:. ;-ti ' ?t: �....._,.�,:.'�,u. ;'3v1.:.JC,; - ... Scope of Work (please provide detailed information): Street Use: ❑ .. Street Use Land Altering and /or Hauling: ❑ .. Land Altering: 0...Cut Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Vpplicationalpermit application (1 -2003) 1/2003 Call before you Dig: 1-800-424-5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑... Channelization /Striping Storm Drainage: ❑ .. Storm Drainage ❑...Flood Control Zone Water ... ❑ cubic yards 0... Fill 0... Curb cut/Access /Sidewalk Sewer Information: ❑ . City of Tukwila Sewer District ❑ .. Val Vue Sewer District 0... City of Renton Sewer District ❑ .. City of Seattle Sewer District 0.. Sanitary Side Sewer 0.. Sewer Main Extension ❑ ..Private ❑ .. Public Water Information: ❑ .. City of Tukwila Water District ❑ .. Water District # 125 0... Highline Water District ❑...City of Renton Water District ❑ .. Water Main Extension 0.. Private ❑...Public ❑ .. Water Meter/Exempt: Size(s): ❑.. Deduct ❑...Water Only ❑ .. Water Meter Permanent #: Size(s): ❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons 0 .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation ❑ .. Miscellaneous: City Sewer ... ❑ Sewage Treatment ❑ City cubic yards ❑ .. Hauling Day Telephone: State Fire Line .... ❑ Zip Day Telephone: State Zip Unit Type:.. Qty Unit Type:: Qty Unit Type: Qty Boiler /Compressor:. Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator —Comm/Ind MECITANICALPERMIT INFt.AcMATION 206. =3670 • MECHANICAL CONTRACTOR INFORMATION Company Name: Pit o -S TA nlr (HA cA 1 Mailing Address: Po SG X 33 7o Std m GC w, R.y > ; 3 City Stalc Zip Contact Person: �` 0/ Day Telephone: � -a 6) .3 6 (- u 1 I E -Mail Address: - wt a7 r ro =C 4 e ra o ciA n i cq E . cq+i Fax Number: (2 :46/ - o U 2 `F Contractor Registration Number: It rM 107 LNG Exp iration Date: { `30 /rD't * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ "I") 3 q 5 , 00 Scope of Work (please provide detailed information): A 0) 4e w 2 --1 j n s A (ec{ r ; c. roof Cor"t(le Fe w. 4 L yl c) 4.c.f d es{ ✓tb . o„t d(' C"to Use: Residential: New ....❑ Replacement ....0 Commercial: New .... E'' Replacement ....0 Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: `PERMIT APPLICATION NOTES,— all permits ><n th>IS apphcatio Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT .• RIZED AGENT: Signature: Print Name: Mailing Address: \applicationa\permil application (1.2003) 1/2003 Page 4 City o () roq trek lhtnI Otte. 1'11ee l Date: S 1 ° Day Telephone: State A4 /c. u l r f 0n Zip Date Application Accepted: Date Application Expires: /( - Z 2 - o3 Receipt No.: R03 -00664 Initials: SKS User ID: 1165 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2523049034 Permit Number: M03 -079 Address: 817 INDUSTRY DR TUKW Status: APPROVED Suite No: Applied Date: 05/22/2003 Applicant: RREEF (VACANT SPACE) Issue Date: Payee: PRO -STAFF MECHANICAL INC ACCOUNT ITEM LIST: Description doc: Receipt Payment Check 7489 MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Payment Amount: 47.88 Payment Date: Balance: TRANSACTION LIST: Type Method Description Amount 47.88 Account Code Current Pmts 000/322.100 38.30 000/345.830 9.58 Total: 47.88 05/30/2003 10:01 AM $0.00 9116 06/02 9716 TOTAL 47.88 Printed: 05 -30 -2003 Project: j e e.� - ( V aL a- Type of Inspection: ) Address: r - .1 Ll-vdu � Q. Date Called: , a J Special Instructions: P (- eet.�x C:6'� (Z Date Wanted: r, a U3 Requester: ' D ill Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA‘98188 Approved per applicable codes. E] Corrections required prior to approval. COMMENTS: ` t;6 Cow1l-e4e J 1 V\ Inspect &: 4 1 47.00 REINSPECTION FEE R Date: r j ` � _ O � D $ QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: (206)431 -3670 COMMENTS: Q 0,.t ‘ v, - ck r o ved Typect ri o Ad r s: �7 _Z a s�f� -t D Date Cal: Called: 07 Specia I nstructions: II I1 CL ( ✓" {LC 1 ek v (Iv et_, d 1k1/4-. = *)-)j) t Ins Pt inv. Phone (ni/n L¢ 4-e -- a e?voih-rof N p UV' 4- ‘ V'fA l \ A \ r1/ IMbSAGi 1 Pr ect: Typect Ad r s: �7 _Z a s�f� -t D Date Cal: Called: 07 Specia I nstructions: II I1 CL ( ✓" {LC 1 ek v (Iv et_, d Date Wanted a .m 91,/0_3 p Reque er: K! �K Phone D _ EOg`!J 0Co-5 // ,INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 IA 0 5- diq PERMIT (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. Inspector: Date: t ` ) 4 0 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. z 1 Z W re 2 J U 0 U 0 . W w O LL a N = � W O� ui D O U N 0 H W W 1 U -- 11 - - O tiJ z O� z File: M03 -0079 35mm Drawing #1 •'1 6W BUILDING SIZING SUMMARY Building Name : 817 Industry Location : Seattle- Tacoma, Washington Block Load Lite v1.00 Prepared By : Pro -Staff Mechanical,Inc Page 1 of 1 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 1. INPUT DATA City State Data Source Latitude Elevation TABLE 2. INPUT DATA -- BUILDING System Type : Clg & Warm Air Htg System Start 700 Duration 16 hrs SIZING SPECIFICATIONS Supply Ventilation Exhaust FAN Configuration : Blow -Thru Static Pressure TABLE 3. SIZING DATA -- COOLING Total coil load = Sensible coil load = Total sensible = Supply temperature = Supply air (actual)= Supply air (std) _ Ventilation air = Direct exhaust air = Reheat required = Floor area (sqft) Overall U -value Vent air CFM /sqft Vent air CFM /person Heating coil load = Ventilation load = Total load = Ventilation airflow= Supply airflow = WEATHER = Seattle- Tacoma = Washington = User Modified = 47.5 deg. = 386.0 ft 1.50 55.0 F 160 CFM 50 CFM 22,227 15,428 13,691 55.0 643 634 160 50 0 in. 620 0.136 = 0.26 = 20.00 TABLE 4. SIZING DATA -- HEATING 17,038 BTU /hr 7,838 BTU /hr 9,200 BTU /hr 160 CFM 643 CFM FILE COPY I 'MIFF an Chen ap ov T :4 � � re : 1 3 G i � � �� r I 47 p � of : .Dai l.y.. Rang .2 2 r. 0', .F Winter • dry -bulb. . :�f x0y 4. c :a :T g ' Atmos. Clear Num = i ,4 t . 01D MAY 2 8 2003 - tithe THERMOSTAT SETP Cooling (Occ)I0fL K Cooling (Unocc) : 75.0 Heating 70.0 FACTORS Coil Bypass Safety (Sens) Safety (Latent) Heating Safety RETURN AIR PLENUM Total coil load Sensible coil load SQFT /Ton Cooling BTU/hr/sqft Cooling CFM /sqft Heating BTU /hr /sqft = Heating CFM /sqft = Floor area (sqft) _ Overall U -value = Vent air CFM /sqft = Vent air CFM /person = • • • • F F 0.050 0 W • 0 s • • 0 W N CITY RECEIVED TUEKWILA MAY 22 2003 PERMIT CENTER BTU /hr Load occurs C June 1500 BTU /hr Outdoor Db /Wb = 81.0/ 72.0 F BTU /hr Coil Conditions: F Entering Db /Wb = 77.5/ 66.1 F CFM Leaving Db /Wb = 55.0/ 54.5 F CFM Apparatus dewpoint= 53.8 F CFM Bypass factor = 0.050 CFM Resulting RH = 53.7 W BTU /hr 1.85 Ton 1.29 Ton 334.73 35.85 1.04 27.48 1.04 620 0.136 0.26 20.00 ******************** * * * * * * *. * * * * * * * * * * * * * * * * * * * * * ** SIZING SPECIFICATIONS Supply Ventilation Exhaust 6W BUILDING DATA FOR 817 Industry Prepared By : Pro -Staff Mechanical,Inc i1 -28 -82 Block Load Lite Program v1.00 Page 1 of 2 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Table 1. HVAC SYSTEM DESCRIPTION System Type : Clg & Warm Air Htg THERMOSTAT SETPOINTS System Start 700 Cooling (Occ) 75.0 F Duration 16 hrs Cooling (Unocc) : 75.0 F Heating 70.0 F 55.0 F 160 CFM 50 CFM FAN Configuration : Blow -Thru Static Pressure : 1.50 in. FACTORS Coil Bypass Safety (Sens) . Safety (Latent) : Heating Safety . 0.050 0 % 0 % 0 % RETURN AIR PLENUM : N ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 2. GENERAL BUILDING DATA GENERAL BUILDING DATA Floor Area 620.0 sqft Building Weight: M Exposures : N, E, S, W Are Multiple Wall, Roof, or Glass Types Used ? N No. Partitions : 0 LIGHTING W /sqft 1.20 W /sqft Unocc Diversity: 0 % Wattage Mult. 1.00 Fixture Type : Rec., Not Vented OTHER ELECTRIC W /sqft 1.00 W /sqft Unocc Diversity: 0 PEOPLE Total People Unocc Diversity: Activity Level : Sensible Gain . Latent Gain MISCELLANEOUS LOADS Sensible Latent Unocc Diversity: INFILTRATION Cooling Heating SLAB Area Perimeter Depth 8 People 0 % Office Work 245.0 BTU /hr /per 205.0 BTU /hr /per 0 BTU /hr 0 BTU /hr 0 % 0.10 CFM /sqft 0.10 CFM /sqft 620 sqft 24 ft 2.00 ft ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** BUILDING DATA FOR 817 Industry Prepared By : Pro -Staff Mechanical,Inc 11 -28 -82 Block Load Lite Program v1.00 Page 2 of 2 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 3. WALL, ROOF AND GLASS DATA U -Value (BTU /hr /sqft /F) Weight (lb/sqft) Color EXTERNAL SHADING DATA Window Height = Window Width = Reveal Depth = Exposure E Wall S Wall W Wall N Wall Roof (Hor) WALL 0.080 M M 7.0 ft 4.0 ft 2.0 in ROOF GLASS 0.050 L D Overhang Height Overhang Extension Fin Separation Fin Extension Gross Area Glass Area (sqft) (sqft) 180.0 0.0 0.0 36.0 620.0 U -Value Glass Factor Int. Shades ? 70.0 0.0 0.0 28.0 0.0 0.750 1.00 N 0.0 in 0.0 in 0.0 in 0.0 in ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 7 DETAILED BUILDING LOAD REPORT Building Name : 817 Industry 11 -28 -82 Location : Seattle- Tacoma, Washington Block Load Lite v1.00 Prepared By : Pro -Staff Mechanical,Inc Page 1 of 1 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 1. LOAD COMPONENT SUMMARY for June 1500 ( 81.0/ 72.0 F) Load Component Solar Loads Wall Transmission Roof Transmission Glass Transmission Skylight Transmission Partitions Lighting Other Electric People Infiltration Miscellaneous Slab Pulldown /Warm -up Safety Factor Total Loads Ventilation Load Supply Fan Load Plenum Load Thru Wall Plenum Load Thru Roof Plenum Load - Lights Reheat Load Details 98 sqft 118 sqft 620 sqft 98 sqft 0 sqft 0 sqft 1.20 W /sqft 1.00 W /sqft 8 people 0/ 0/ 0 % Total Coil Loads 15,428 TABLE 2. WALL AND GLASS BREAKDOWN Component Walls : NE E SE S SW W NW N Glass : NE E SE S SW 0 70 0 0 0 620 sqft 160 CFM 643 CFM 0 % 0 % 0 0 0 110 188 0 0 0 0 0 0 0 0 0 0 8 2 Design Cooling Loads Sensible Latent (BTU /hr) (BTU /hr) 0 112 0 0 0 5,181 190 1,984 157 0 0 2, 193 1,962 1,628 1,640 396 1,441 0 0 0 0 0 1,022 715 0 0 0 0 0 4,429 0 0 0 13,691 3,081 3,718 Design Heating (BTU /hr) 434 1,426 3,381 0 0 3,037 921 0 9,200 7,838 6,799 17,038 Total Cooling Cooling Heating Net Area Transmission Solar Load Transmission (sqft) (BTU /hr) (BTU /hr) (BTU /hr) 0 405 0 0 0 0 0 29 0 2,415 0 0 0 W NW N Hor 0 0 0 0 0 0 0 0 28 45 752 966 0 0 0 0 CITY OF TW W LA APPROVED MAY 2 8 2033 AS FY01ED .r?' h.h P, rNt...s TRANE' FIL ' COPY Package Gas/ Electric Units Convertible Models YCC018 -060F 1 -1/2 5 Ton YC -D -9 RECEIVED CITY OF TUKWILA 2.2 2_0t)3 PERMIT CENTER z W J0 0 W = W � • ° w z � zr w O co 0- 0 H- W W F- LL O .. z W U= 0 z MODEL RATED VOLTS /PH/HZ A.R.I. RATINGS (COOLING)® BTUH Indoor Air Flow (CFM) System Power (KW) EER /SEER (BTU/WATT -HR.) Noise Rating No. A.G.A. RATINGS (HEATING)® (High) Input BTUH Capacity BTUHOO AFUE Temp. Rise °F (Min. /Max.) (Low) Input BTUH BTUHO® AFUE/ E Temp. Rise °F (Min. /Max.) Type of Gas® POWER CORNS. - V/PH /HZ Min. Bich. Cit. Ampacity Br. Cir. - Max. (Amps) Prot. Rtg. - Recmd. (Amps) COMPRESSOR No. Used Volts /PH /HZ R.L. Amps - L.R. Amps OUTDOOR COIL - TYPE • Rota /F.P.I. Face Area (Sq. Ft) Tube Size (in.) INDOOR COIL - TYPE Rows / F.P.I. Face Area (Sq. Ft.) Tube Sae (m.) Refrigerant Control Drain Conn. Size (in.) Duct Connections OUTDOOR FAN - TYPE No. Used / Dia. (in.) Type Drive / No. Speeds No. Motors - HP Motor Speed R.P.M. Volts /PH /HZ F.L. Amps - L.R. Amps INDOOR FAN - TYPE Dia. x Width (in.) No. Used Orrye / Speeds (No.) No. Motors - HP Motor Speed R.P.M. Volts /PH /HZ F.L. Amps - L.R. Amps COMBUSTION FAN - TYPE Drive - Speeds (No.) Motor HP - Speed (RPM) Volts/PH/HZ F.L. Amps FILTER - FURNISHED? Type Recommended Min. Face Area-Lo (ft.) ®O REFRIGERANT Charge (Ibs. of R-22)® GAS PIPE SIZE (IN.) DIMENSIONS Crated (in.) Uncreted WEIGHT Shipping (Ibs.) / Net (Ibs.) See notes on page 14 8 YCC0111FILOB 208- 230/1/80 18000 600 1.93 9.35 / 10.00 8.0 50000 408% 30 / 60 40000 32000 78 %/76% 30 -60 NATURAL 208 - 230/1/60 ' 13.2 20 20 CLIMATUFr 1 200 - 230/1/80 8.0 - 48 PLATE FIN 2/15 4.5 3/8 COPPER PLATE FIN 2/15 3.25 3/8 COPPER CAPILLARY 3/4" FEMALE NPT SEE OUTLINE DRNMNGF PROPELLER I 1/18 DIRECT / 1 1 -1/5 1080 200 - 230/1/60 1.8 - 3.3 CENTRIFUGAL DIRECT / 2 1 -1/4 1080 200 - 230/1/60 1.8/1.4 - 2.9 CENTRIFUGAL DIRECT -1 1/35 - 3480 240/1 /60 0.6 NO THROWAWAY 2.0 3.8 Ibs. 1/2" HXWXD 31- 1/4X38X5 SEE OUTLINE D NG 341 / 301 General Data I i -f/L YCCO24FILOB 208- 230/1/60 23400 800 2.55 9.10 / 10.00 8.0 50000 40000 78% 30 / 60 40000 32000 78 %/76% 30 - 60 NATURAL 20B- 230/1/60 15.7 25 25 CUMATUFFTM 1 200 - 230/1/60 10.0 - 67 PLATE FIN 2/15 4.5 3/8 COPPER PLATE FIN 3/15 3.25 :.. 3/8 COPPER CAPILLARY 3/4" FEMALE NPT SEE OUTUNE DRAWING PROPELLER 1/18 DIRECT / 1 1 -1/5 1080 230/1 /60 1.6 - 3.3 CENTRIFUGAL 9X9 DIRECT / 2 1 -1/4 1080 200 - 230/1/60 1.6/1.4 - 2.9 CENTRIFUGAL DIRECT - 1 1/35 - 3480 240/1/60 0.6 NO THROWAWAY 2.67 4.0 Ibs. 1/2" HXWXD 31- 1/4X38X57 SEE OUTLINE DRAWIN 35 YCCO30F1 LOB 208 -230/1 /60 29200 1000 3.17 9.20 / 10.00 8.0 50000 40000 30 / 60 40000 78% / 30 -.60 NATURAL 208 - 230/1/60 20.1 30 30 CLIMATUFP" 200 -230/1 /60 13.3 - 79 PLATE FIN 2/15 5.43 3/8 COPPER , -PLATE FIN, :•.. 3.25 3/8 COPPER CAPILLARY 3/4" FEMALE NPT SEE OUTLINE DRAWING PROPELLER 1/,18 DIRECT / 1 1 -1/5 1080 230/1/60 1.6 - 3.3 CENTRIFUGAL 9X9 DIRECT/ 2 1 -1/4 1080 200 - 230/1/60 1.6/1.4 - 2.9 CENTRIFUGAL DIRECT -1 1/35 - 3480 240/1 /60 0.8 NO THROWAWAY 3.33 4.4 Ibs. 1/2 HXWXD 31 -1/4 X 38 X 57 SEE OUTLINE DRAWING 398 / 358 YCCO30F1MDB 208 - 230/1/60 29800 1000 3.27 9.10 / 10.00 8.0 75000 60000 78% 35/85 48000 78 %/76% 35 - 65 NATURAL 208-230/1/60 21.3 35 35 CLIMATUFP" 1 200-230/1/60 13.5 - 79 PLATE FIN 2/15 5.43 3/8 COPPER PLATE FIN 3/.15 3.96' 3/8 COPPER CAPILLARY 3/4" FEMALE NPT SEE OUTLINE DRAINING PROPELLER 1/18 DIRECT / 1 1 -1/5 1080 230/1/60 1.6 - 3.3 CENTRIFUGAL 10 X 9 DIRECT / 2 1 -1/3 1080 200 - 230/1/60 2.8/2.2 - 5.1 CENTRIFUGAL -1 1/35 - 3480 240/1/60 0.6 .. . NO THROWAWAY 3.33 4.5 Ibs. 1/2" HXWXD 35 -1/4 X 38 X 57 SEE OUTLINE DRAWING 398 / 358 • • Side Distance (In.) Bottom 0.0 Back (Duct) 1.0 Left 6.0 Right 6.0 Front 12.0 Top 36.0 SERVICE CLEARANCE DIMENSIONS MODEL NO. A B C D YCC018 -036F -L VCCO30,036F -M 2'6" 2'6• 6 "• 2'0" MODELS AIR DUCT OPENINGS A B C D '.Y00018 -038F -L YCCO30,038F -M SuVpiyDuct 21 11 -1/4 — — Return Duct — — 11 -1/2 18-1/8 (AN dimensions are in nches) 32 1'6' with 26% Fresh air accessory 2'8' with Economizer Dimensional Data BAYCURB030 Roof Mounting Curb Outline YCC018 -036F— Units Required Clearance for Unit Installation and Roof Penetration Hole Size Required From Dwg. 21D729942 Rev. 2 Clearance From Combustible Materials From Dwg. 210662114 Rev. 0 • w J U. 0 W w J w ? . N I-- w Z �. 1- z W uj U O E E- 11) 11 0 • w Z 0 - O z SUPPLY AIR DUCT DIVIDER DUCT SUPPORT ROOF MOUNTING CURB SIDE RAIL NOTES: 1. OVERLAP AND POSITION JOINTS IN P.V.C. RUBBER GASKET. 2. AIR SEALS := APPLY P.V.C. RUBBER LAST TO INSURE THERE IS ADEQUATE P.V.C. FOR THE WATER SEAL. 3. USE TYPICAL SEALING METHODS TO PREVENT AIR DUCT LEAKAGE AT CURB -DUCT JOINT. Dimensional Data Field Fabricated (Side X Side) Ducts — YCC018 -060F Units Installed from Above Mounting Curb 3 /4" FLANGES (TYP. FOR BOTH DUCTS) ../ ' � END RAIL I This member on YCC018-036F-L models only. I P.V.C. Rubber Gasket Position on BAYCURB030AA for Unit Placement — YCC018 -060F Units GASKET SEAL x W P.V.C. GASKET THIS PORTION OF GASKET IS OPTIONAL This member on YCC018- 036F -L models only. CABINET SIZE MODEL "A" "B" "C" "D" "E" "F" "G" "H" YCC018 & 024, YCCO30F -L 14 -1/8 16 -5/8 36 34 25 -3/16 13 -3/4 — — YCCO30E-M, YCCO36F -L, YCCO36F -M 14 -1/8 16 -5/8 • 36 34 29 -3/16 13 -3/4 — — YCCO36F-H, YCC042F -M, YCC048F -M 14 -1/8 16 -5/8 36 34 29 -3/16 13 -3/4 8 -1/8 7/8 "D" YCC048F -H, • YCC060F -M 14 -13/16 21 45 34 33 -3/8 13 -3/4 10 -1/8 9 -7/8 i i . l l O.D. COIL HOLD DOWN CLIP "D" CABINET UNIT BASE CURB Dimensional Data YCC018 -060F Outline — Front with BAYCURB030A Curb (ALL DIMENSIONS ARE IN INCHES) CORRECT UNIT GASKET ECONOMIZER CURB —�� INCORRECT GASKET From Dwg. 21D661772 Rev. 0 " CABINET ''1' f f O.D. COIL HOLD DOWN CLIP "D" CABINET UNIT BASE CURB Dimensional Data YCC018 -060F Outline — Front with BAYCURB030A Curb (ALL DIMENSIONS ARE IN INCHES) CORRECT UNIT GASKET ECONOMIZER CURB —�� INCORRECT GASKET From Dwg. 21D661772 Rev. 0 " CABINET MODEL A B C D E F YCC018 /024F -1. YCCO3OF -1. ' 55.1/4 36 26-3/16 12 -15/16 36-3/4 KNOCKOUTS FOR 1/2' AND 1' CONDUIT YCCO30F M YCCO38FL/F -M 65 -1/4 36 29-3/16 12 -15/16 36.3/4 KNOCKOUTS FOR 3/4' AND 1-1/4' CONDUIT YCCO36F -H YCC042F -M YCC048F4M 62-3/4 36 29-3/16 14-1/2 27-1/2 KNOCKOUTS FOR 3 /4'AND 1-1/4' CONDUIT YCC048F -H YCCO60F -M 64.5/18 45 33.3/8 14.13/16 27.15/16 KNOCKOUTS FOR 3 /4'AND 1-1/2" CONDUIT • CONTROL BOX ACCESS PANEL HOLE FOR 1/2" CONDUIT (UNIT CONTROL WIRES) D 48 Dimensional Data YCC018 -060F Outline — Front (ALL DIMENSIONS ARE IN INCHES) F UE 1" DIAMETER K.O. FOR 1/2 N.P.T. CAS CONNECTION 0UBUSTION BLOWER ACCESS AS VALVE ACCESS CONDENSER COIL IN THIS AREA ONLY ON YCC042F —M, YCC04EF .41 ONDENSER COIL C From Dwg. 21D661689 Rev. 0 2 Z ' '„ W J U 0 0. co o . W W J (/) IL W 0; J LL. OD Z � Z O W W U D 0 W W (I6 O' w Z U= 0 I– z CURET MODEL CORNER WEIGHT II m UNIT WEIGHT REIMS.) A 8 C D E F G H J K 1 M N P wt W2 W3 W4 1, A YCCOI8F -1. 68.3 61.7 84 92.9 307 55-1/4 36 25-3/16 18 -9/16 11. 1/16 6-9/16 6.13/16 17 21.5/16 25 17.1/2 10 3 4-7/16 YCCO24F -L 69.4 60.0 85 99.5 314 YCCO30F -1. 70.5 61.4 87 99.8 319 B YCCO36FL 64.06 68.08 92.1 113.7 358 55.1/4 36 29-3/16 18 -9/16 11-1/16 6-9/16 6-13/16 17 20-3/4 25-13/16 17 -1/2 10 3 4.7/16 YCCO30F -M 78.3 68.3 95.6 109.7 352 19-3/4 2413/16 YCCO36F -M 56 67.6 93.2 115.13 364 C YCCO36F41 90.3 73.8 101 123.7 389 62.3/4 36 29-3/16 18.9/16 11-1/16 6-9/16 11.1/8 17 19-3/4 28-1/4 17 -1/2 10 3 8-3/4 YCC042F -M 103.7 88.7 96.8 122.6 412 19-3/4 28-1/4 YCC048F -M 104.6 84.6 102.2 126.4 418 19-3/4 28-1/4 0 YCC048FII 123.8 104.6 132.5 157 518 64 -5/16 45 33-3/8 21.1/16 15.1/16 4-15/16 9-1/8 21.15/16 25 29.1/2 29.1/2 20 14 3-1/2 8-5/16 YCC060F -M 135.4 109.8 137.3 169.3 552 25 38 . Dimensional Data and Weights YCC018 -060F Outline - Rear (ALL DIMENSIONS ARE IN INCHES) C HORIZONTAL SUPPLY OPENING DOWNFL SUPPLY OPENING HORIZONTAL RETURN OPENING SECT. X -X TYPICAL CROSS SECTION OF SUPPLY & RETURN PERIMETER FLANGES APPEARANCE SURFACE OF SUPPLY & RETURN PANEL L * M D IMENSIONAL SURFACE I SEE TABLE) EVAPORATOR COIL & BLOWER PANEL 1i DIA. ENTRY FOR 1/2 N.P.T. GAS CONNECTION CONDENSATE DRAIN FOR 3 \4" FEMALE NPT DOWNFLOW RETURN OPENING SECT Y -Y TYPICAL CROSS SECTION OF DOWNFLOW SUPPLY & RETURN PERIMETER FLANGES rom Dwg. Z1D6ti1baU Hev. ECONOMIZER.. ,r APPLICATION : MODEL MODELS A 8 C D E F G H BAYECON054AA YCC018 -042F 20 16 -5/8 23-1/2 22 -9/16 8 -5/8 22-1/4 25 -1/8 1 -1/2 BAYECON055AA YCC048 -060F 20 21 26 OMIT 12 -1/8 26 -1/8 32 -1/8 1 -3/4 MIST ELIMINATOR 16 X 20 X 1 GASKETED ATTACHMENT FLANGES ECONOMIZER RAIN HOOD Optional Equipment D ': Economizer and Rain Hood (Downflow Applications) : END PANEL (ECON054AA MODEL ONLY DISC TYPE THERMOSTAT ECONOMIZER MOTOR C BAROMETRIC RELIEF CONTROL MODULE MOTOR DECK CONE GROMMET MIXED AIR SENSOR From Dwg. 21D730082 Rev. 2 31 � U : 0 U 0 CO W W LL Q 2 I W 2' Z H 0 : Z 0 0 N 0 I-' til Z U ± : Z ACTIVITY NUMBER: M03 -079 DATE: 5 -22 -03 PROJECT NAME: RREEF (VACANT SPACE) SITE ADDRESS: 817 INDUSTRY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: 4 Building Division Public Works n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Complete PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTI G: Please Route Structural Review Required Approved with Conditions Approved ❑ Notation: APPROVALS OR CORRECTIONS: Documents/routing slip,doc 2.28-02 M51 n itt- b-2-3&5 Fire Prevention REVIEWER'S INITIALS: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator DUE DATE: 5-27-03 Not Applicable n No further Review Required DATE: DUE DATE: 6 -24-03 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 6 J0 00 to w w J U) w w u_ cop _° z F I— O w U � O59. 1— w w 0 i= u. O w z U= O ~ z . 4 5 1 :4 bt tseatik..sti4) S 14s- aoTAPT v• e • cr... .. e• •d V.' • 1° 1 0 t • My appointment expires • i p% ' .!.q • , 0?4b;i: . it• State of Washin toe County of * 'ter riTy of A docusent ; e possession.of, fit? g the Medita4te-4 as of this ate. Dated: (444 (Signature of Notary Public) /VP Title REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # CCO1 PROSTMI072NG EFFECTIVE DATE PROSTAFF MECHANICAL PO BOX 33370 SEATTLE. WA- 38133 ! i I I ! I ' • I , • : INC EXP. DATE 06/30/2004 08/07/1993 LICENSED AS PROVIDED BY LAW AS ELEC CONTR HVAC/RFRG LICENSE # EXP. DATE EC6A PROSTMI006C8 02/28/2004 EFFECTIVE DATE 02/28/2000 PRO-STAFF MECHANICAL INC PO BOX 33370 SEATTLE WA 98133-8031 • 1 File: M03 -0079 35mm Drawing #1 NEW TRANS GAS/ELECTRIC PACKAGED AC EQUIPMENT SCHEDULE SIZE CFM 2 -Ton 800 VICINITY MAP EQUIPMENT NOTES: 1. Economizer. 2. Factory Roof Curb. 3. Insulate all ductwork per code. R -7 4. Outside air intake to be 10' - 0" from exhaust outlet, gas flues & plumbing vents. 5. Honeywell 7-Day programmable night setback thermostat with 5 degree dead -band capability. COOLING (BTU COOLING EER/SEER 9.10/10.00 • SCOPE OF WORK: • One new Trane 2 -Ton gas /electric AC unit with factory roof curb, economizer programmable thermostat. and ♦ Ductwork distribution, diffusers and grilles. • Gas piping. • Crane, equipment start -up & test, in -house comfort air balance. HEATING HEATING INPUT OUTPUT 50,000 40,000 AFUE 78% 1 Inch i 1 G E STCOTT ® Since 18721 III�ll ►I�I;� 2 1 3 VOLTAGE 2 - 230/1/60 FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. I1II1II 1Ili1 4 ELECTRICAL MCA =15.7 FUSE = 25 By Date Permit No. • NO CHANGES SHALL BE MADE TO THE SCOPE ItF , ,. I 'ON( WITHOUT PRIOR APPROVAL OF i! K °.ILA f I„ LD NG DIVISION. (=NOTE: REVISIONS WILL R e,/ tirP.5 A. NEW 'PLAN ,SUBMITTAL WEIGHT (LBS.) 310 HVAC FLOOR PLAN I SCALE 1/8 " =1' 0" M O- 111111111 1 1 111111 I 1111111 51 6 G b6 Et. Z6 61. 06 6 8 L 9 9 P s Z . wo iiiili111111111111111111lIl!I IIIIIIIIIIIII! lili111111111111iiiiliiii1iiiiliiii1iiii111111iiiili IIII IIIIIIIIIIIIIIIIII�IIIIIIilllllllllllllllllllllll r Ac- � 3 CITY Of RAW APPROVED MAY 2 8 2003 As WED t".:ii.:11-:VARATE PERMIT REQUIRED FOR: 0 mr,CHANICAL 1 i. EI..ECTRICAL ehLU IBIN G reGAS PIPING CITY OF TUKWILA BUILDING. DIVISION if- NEW ' . i6 -77 E S '11 2 0 -