Loading...
HomeMy WebLinkAboutPermit M03-092 - PACIFIC SUNWEARPACIFIC SUNWEAR 17340 SC PARKWAY M03-092 Signature: Permit Center Authorized Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049079 Address: 17340 SOUTHCENTER PY TUKW Suite No: Tenant: Name: PACIFIC SUNWEAR Address: 17340 SOUTHCENTER PY, TUKW ILA, WA Owner: Name: MBK NORTHWEST DEPT 436 Address: P 0 BOX 34935, SEATTLE WA Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105, KENT, WA Contractor License No: COMFOMI015LA Value of Construction: $80,000.00 Type of Fire Protection: E F L ` 6 'R-N2._ MECHANICAL PERMIT Contact Person: Name: JEFF GANZER Address: COMFORT MECHANICAL, 6830 S 220TH ST DESCRIPTION OF WORK: INSTALL THREE 4 -TON HEAT PUMPS WITH NIGHT SETBACK THERMOSTATS; PROVIDE AIR DISTRIBUTION SYSTEM; PROVIDE AND INSTALL TOILET EXHAUST FAN. Fees Collected: Uniform Mechnical Code Edition: 1997 Permit Number: MO3 -092 Issue Date: 06/17/2003 Permit Expires On: 12/14/2003 Phone: Phone: 425 251 -9840 Phone: 425 - 251 -9840 Expiration Date:06 /01/2004 $194.31 Date: 77--3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance f work. I am authorized to sign and obtain this mechanical permit. Date: 6- 0 .5 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M03 -092 Printed: 06 -17 -2003 Parcel No.: 2623049079 Address: 17340 SOUTHCENTER PY TUKW Suite No: Tenant: PACIFIC SUNWEAR 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS M03 -092 Permit Number: M03 -092 Status: ISSUED Applied Date: 06/11/2003 Issue Date: 06/17/2003 Date: 0 /P v 3 Printed: 06 -17 -2003 z 6U 00 ND J CO IL H w g Q d 1— w z � � z I- w w U O N t- wW Li: O w 0 z CITY OF TUKWILA Community Development department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 sITELOCATI . 40 ao-re ?Pc Tenant Name:PACIF.lc_Su We.o.e.__ SA - 0 ft Property Owners Name: K wt d-o Re-4 A e Mailing Address: 5l3 t M Act4 LTA. 111- Site Address: Name: 3 C.7 2.-e--( Day Telephone: ( Liz5) 2 tirS Li 0 Mailing Address: (get 5 22.0 'ST , Lki A- 2' 0 3 z City \ State Zip Fax Number: ( Z c l 1 E-Mail Address: (2) COW (-Or2..1 co %An \- es - r •i * X-55 DA-t1-5 L 2-1 o C--rAN3 4.4 ‘15-lew t ke_ c-4. 92-G3 I City State Zip Day Telephone: \ '6 Fax Number: l Expiration Date: An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** Company Name: Mailing Address: Contact Person: C_.0 TT HA‘ E-Mail Address: Contractor Registration Number: • Company Name: Pv A rJ t LTZ Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Mailing Address: V)42. 5 t3. /Ac e. ) Loof Contact Person: - 1" - %%iv, 6r-7 k- G--a-- E-Mail Address: Company Name: Mailing Address: Contact Person: E-Mail Address: tapplicationskpennit application (3-2001) 3/2003 Page 1 King Co Assessor's Tax No.: e_i1/4.0-1•43 City Suite Number:V 0 Floor: New Tenant: fl .... Yes ID ..No C State C t 510 0 Zip S e.mt - k NI-E- A o City State Zip Day TelephoneC6 0 - 42../0 Fax Number:Q o 1) ° VA - 2 2 ENGINEER: OVRECOlta....:Aq:01400 ni0t.be.Wet st0100bi;0giiteer..:9fRieffied ' State Zip City Day Telephone: Fax Number: t.BUILVIINIt r YE .Y 11Vk UK11�A:1 `llJPty== ? 4! U ,, Qt9M'3b Lu ' sali'aivt,gt.ii 4Y. Valuation of Project (contractor's bid price): Will there be new rack storage? [] ..Yes ❑ .. No lapplicationalpermit application (3400)) 3/2003 Page 2 5 . � Existing Builc.. o Valuation: S Scope of Work (please provide detailed information): If "yes ", see Handout No. for requirements. FrovideAll Building Area s in Square Footage '• Below '. '`•Floor 2 " Floor • 3 Floor Floors Basement Accessory Structures Attached Garage, Detached Garage Attached Carport Detached Carpo Covered Deck • ,: Uncovered Deck - Additidn to : ' ? :: _..Existing Structure. '.. - Type of Construction per UBC Type•of ;...:. Occupancy Per UBC PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑..Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No If ' yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. r 3PUBL CiWO RI{S PERMIT INFQIttk[AiU 4 Z • . 1i• ; .:�ii ' r0 pt : ¢; �,i .Po-^ r• •:Y�S1cr;:. ■ Scope of Work (please provide detailed in.,..mation): Please refer. to Public Works Bulletin #1 for fees and estimate sheet. Water District ...Tukwila 0... Water District #125 ❑ ...Water Availability Provided Sewer District ❑...Tukwila D... ValVue ❑ .. Renton ❑...Seattle ❑...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance 0 ...Construction /Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ...Total Fill cubic yards cubic yards ❑...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ...Backflow Prevention - Fire Protection Irrigation Domestic Water „ ❑...Permanent Water Meter Size... [...Temporary Water Meter Size.. O.-Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ... Water Main Extension Public tapplication,tpermit application (3.2003) 3/2003 ❑ .. Abandon Septic Tank 0 .. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line „ Call before you Dig: 1- 800 -424 -5555 WO# WO# WO# Private Private Page 3 33= Ui79 t.;' -5! ti: ❑ .. Highline .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance .. Work in Flood Zone ❑ .. Storm Drainage 0 ...Renton [] .. Grease Interceptor 0 .. Channelization .. Trench Excavation 0 .. Utility Undergrounding ❑...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line 0 ... Water ❑ ...Sewer Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) 0...Sewage Treatment Day Telephone: Mailing Address: Zip City State Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: C ity State Zip Q ;H Z c 0 N 0 co u.1 JI CO u_ W u _ co 3 H W Z = ZI- LL! ul U O O I— I— U. O lli = O Z Unit Type: Qty Unit Type: Qty Unit Type:. Qty Boiler /Compressor: Qty Furnace <I00K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 2.. 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System - Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind MECHANICAL..PERNIIT I TF.OR►. _ 2O6=43I 36 t, ,n �y x «•.� r "d +C r \: .�. •I ;�- l�''` MECHANICAL CONTRACTOR INFORMATION Company Name: (.e.C..14 - Act 3 lc A - N C- Mailing Address: 67 `83 0 S co . 22 0 ST V.g-;.3 rt 1 IPtr-- � 2- City State Zip Day Telephone: (2•C) 2.5 ( - his - 4 , 0 Fax Number: - 2 - ) ( 2-'5' ! - c 1 c 6 - Contact Person: JizFF '�• -�'- E -Mail Address: I E-F'F esuv✓ . C`0 -T KIN , L mow\ Contractor Registration Number: E-C- (e P C-0 v ' C MZ 0 0 4 D Pt Expiration Date: (3' c3 1 ! 0 **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 8 to t e ez `- \ Scope of Work (please provide detailed information): FenVLy7 f..4. 1�y t14 (_ ) L TOr'S N'i .t" - 1-0 1 KY 1 it 1•1/41 , P_I t.K.- T 1/4 lrr.(ZAM. O 5T1 S ) TQv v\ o -e. P \ 2 1 ::) lS i e-k. ■3 t)'f, orJ $�.1 �` 1E..ML 2 20 u‘ 0 -e p.,$ D N S'tVkL>,- - V - 0 L L.4�T �X -'- 4 vim' 'r 7-'-N-t--1 t 6 Replacement .... Replacement ....El Fuel Type: Electric [ Gas Other: Use: Residential: Commercial: New ... New ...D Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT ORIZED AGE T: Signature: F ra.ei z a. /e. Mailing Address: ic:.75 3 0 St9 ..D.2 0 kIrt ST , Print Name: %applicationslpermit application (7.2003) 30003 Page 4 Date: to 1 l l 1 0 3 Day Telephone:(y Z 5) 2 S I Q' LI O 1+4_V--N c W P �$ CD3?- Cit State Zip Z . 1- w JU 00 to LO Lu -i � N u_ W u-? Z • = ZO • uj Ucl ON 0 H W W H u. O Ill Z co O F- 2 Date Application Accepted: j Date Application Expires: ' 3 Staff Initi City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT � Parcel No.: 2623049079 Permit Number: M03 -092 Address: 17340 SOUTHCENTER PY TUKW Status: APPROVED U 0 Suite No: Applied Date: 06/11/2003 co w, Applicant: PACIFIC SUNWEAR Issue Date: w i co a. w 0 . Receipt No.: R03 -00732 Payment Amount: 194.31 g Q N 2 Initials: SKS Payment Date: 06/17/2003 09:15 AM H W Us ID: 1165 Balance: $0.00 z P .. F- O zF- w w Payee: COMFORT MECHANICAL, INC. ' m p . U CI 1— CU W TRANSACTION LIST: Type Method Description Amount U, u - F Payment Check 6693 194.31 ai Z' N U 0 H; .Z ACCOUNT ITEM LIST: Description doc: Receipt MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000/322.100 155.45 000/345.830 38.86 Total: 194.31 9683 06/18 7716 TOTAL J.94.31 Printed: 06 -17 -2003 Project. Type of Inspection: Address: f 3'--10 S. C - Vy Date Called: - 7- 31- 03 Special Instructions: Date Wanted: 7 - 31 - U 3 a.m. :rri' Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 A pproved per applicable codes. inspectors INSPECTION RECORD Retain a copy with permit Mo3 09�? PERM (206)431 -3670 Corrections required prior to approval. COMMENTS: r �•P r vVI i C n i -eq-P o -\-r) , (,,, Date: 31- 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: IDate: Project: tCr SV y\ Type + of \vA Inspection: C 5 I v� C' w O l Address: \ ? Sc P Date Called: - q_o Special Instructions: • Date Wanted: a.m. Requester: Phone No: trio.* INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 ' 6)431 -3670 N Approyed per applicable codes. Corrections required prior to'approval. COMMENTS: Inspector: ;,i }a tb Date: , ... c7129_0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: Date: INSPECTION RECORD Retain a copy with permit 1'16 '5- 69 PERMIT COMMENTS: , ) M C T\ S WV:Ale LS hu\ Cl &W v' Q frovoi rQciu,fed 2) . p r_ [t I >l4\ k \vyvv Oos4(&* t k V\&' t ©(.V V��ci� ct p prOVlnl ceci J► Ye Date Wanted: -- 1 ' (� 1 �` O p.m. Requester: Phone No: / t = 300409 vh�civV cal 1 v\ s9�c�lc-v % . Co w\ -t . .. D f( ji.lr in_ ,,,.- CI e1 0 inl1 -e4 Project: �� s . . v Type of Inspection:[" ` 1 s: 1 110 s c k.w 1 Date C alled: `1-8.0 Special Instructions: l a Date Wanted: -- 1 ' (� 1 �` O p.m. Requester: Phone No: . , 4:.,., : '" — .4,y.7:477 t7-- , sue ,s w ;n.,R{... r-:. r.,,,} pry,. _. , . .�. ^S INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. nspecto : Date -7` ag _ ©� $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Z • W r4 2 6= O 0 U) WI J I • u. W � LL = = W i~ Z f.. W ▪ O W U 0 0 W u. O W Z U= o z Proj : r CU..-- - LAil f nsppection: , Add es y 1 ii-t) S,C �� . L`' Date Called: �] 17103 Special Instructions: ate Wanted_, "� � � � /0,3 p.m. Requesc Ph° e INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 So thcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit PERMI 06 431 -3670 Corrections required prior to approval. COMMENTS: 1 ; pi)r r 41-(0),J ,L, S u `. © . C IAA 4r�( 'Q V Qka( -P -}- I�.irlitnli� - 1-a ti Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: P ct: p ra (/ 1 c _San [oat r Type of In pection: ) U C " Address: /73vo SG � D ate Called: co i S D Special Instructions: Date Wanted: ( f C 7 OE a.m. p.m. Requeste7- / , -/U fi ►tee l f $. Phon e 6 _ � � 3 1' COMMENTS: F.; uv ee'f / /-' 4/ r i Inspecto Date: 6 ', . 0 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 1 -3670 Corrections required prior to approval. El $47.00 REINSPECTION FEEREQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Fire Department Project Name 1 L .SVL, Address f ( C� �- t .. current inspecti.on`schedule..,..... Needs shift inspection Approved without correction .no Approved with correction notice issued Sprinklers: Fire Alarm: `7` Hood & Duct: Halon Monitor: Pre -Fire: Permits: Authorized Signajure FINALAPP.FRM City of Tukwila TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM clo y ,/l Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief Permit No. Ai D'3 - 09)- Suite # 7 . 9 Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206- 575-089 TRANE® St) 'FIN 02 UJ 5Urvie. SUtorv:k .Rps • T. Packaged Heat Pumps PrecedentTM 3-10Tons -60 Hz October 2001 RECEIVED CITY OF TUKWILA PERMIT CENTER PKGP-PRC003-EN Unit Cabinet The compact cabinet with rounded corners takes up less room and is less costly to ship. The beveled and ribbed top is not only aesthetically pleasing, it is designed to prevent water from pooling Single Point Power A single electrical connection powers the unit. Compressors Precedent"' contains the best compressor technology available to achieve the highest possible performance. Our compressor line includesTrane -built Climatuff0 reciprocating and scrolls. Easy Access Panels Easy access panels reduce the number of possible water entry points. Low Ambient Cooling All Precedent units have cooling capabilities down to 0 °F as standard. Remove two screws for access to the standardized internal components and wiring. 4 Features and Benefits Easy - Adjust Idler Arm With the Easy- Adjust Idler Arm, the belt and sheaves on belt drive units can be quickly adjusted without moving the mounted fan motor.The result is a major savings in time and money. Colored And Numbered wring You save time and money tracing wires and diagnosing the unit. Convertible Units • The units ship in a downflow configuration.They can be easily converted to horizontal by simply moving two panels. • Units come complete with horizontal duct flanges so the contractor doesn't have to field fabricate them.These duct flanges are a time and cost saver. Unit Base For added water integrity, Precedent has a raised 1 lip around the unit's downflow supply and return to prevent water from blowing into the ductwork. Patented Condenser Coil Precedent boasts a patented 1 +1 +1 Hybrid coil, permanently gapped for easy cleaning. Sloped Drain Pans Every Precedent unit has a non - corrossive, removable, double - sloped drain pan that's easy to clean and reversible to allow installation of drain trap on either side of the unit. Through the Base Condensate Every unit includes provisions for through the base condensate drain connections. This allows the drain to be connected through the roof curb instead of a roof penetration. Foil -Faced Insulation All panels in the Evaporator section of the unit have cleanable foil -faced insulation. All edges are either captured or sealed to ensure no fibers get into the airstream. PKGRPRC003 -EN te-) • mums Table GD-f - General Data Outdoor Sound Rating (dB)' 12 General Data (3,4Ton) 3 Ton Convertible Units 4 Ton Convertible Units WSCO36A1 WSCO36A3,A4,AW WSC048A1 WSC048A3, 4,AW Cooling Performance' Gross Cooling Capacity 38,100 38,100 50,800 50,800 SEER 9.80 10.20 10.50 10.70 Nominal CFM / ARI Rated CFM 1,200 / 1,200 1,200 / 1,200 1,600 / 1,600 1,600 / 1,600 ARI Net Cooling Capacity 36,600 36,000 48,500 48,500 Integrated Part Load Value - - - - System Power (KW) 4.09 3.96 5.16 5.05 Heating Performance' High Temp. Btuh Rating 35,000 35,000 47,000 47,000 System Power KW 3.46 3,35 4.68 4.53 Low Temp. Btuh Rating 18,600 18,600 28,800 28,800 System Power KW 2.78 2.65 4.14 4.02 HSPF (Btu/Watts -hr) 6.75 6.95 6.80 6.90 Compressor No./Type 1 /Climatuff® 1 /Climatuff 1 /Climatuff Scroll 1 /Climatuff Scroll 84 84 83 83 Outdoor Coil - Type Lanced Lanced Lanced Lanced Tube Size (in.) OD .3125 .3125 .3125 .3125 Face Area (sq ft) 9.59 9.59 9.59 9.59 Rows/FPI 2/17 2/17 3/17 3/17 Refrigerant Control Expansion Valve Expansion Valve Expansion Valve Expansion Valve Indoor Coll - Type Lanced Lanced Lanced Lanced Tube Size (in.) .3125 .3125 .3125 .3125 Face Area (sq ft) 6.17 6.17 6.68 6.68 Rows /FPI 3/16 3/16 3/16 3/16 Refrigerant Control Short Orifice Short Orifice Short Orifice Short Orifice Drain Connection No. /Size (in.) 1pA NPT 1 / 3 /. NPT 1 NPT ipA NPT Outdoor Fan - Type Propeller Propeller Propeller Propeller No. Used/Diameter (in.) 1/22 1/22 1/22 1/22 Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM 2,950 2,950 3,200 3,200 No. Motors /HP 1/.25 1/.25 1/.40 1/.40 Motor RPM 1,075 1,075 1,075 1,075 Direct Drive indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used 1 1 1 1 Diameter x Width (in.) 10 x 10 10 x 10 11x 11 11 x 11 Drive Type /No. Speeds Direct/2 Direct/2 Direct/2 Direct/2 No. Motors 1 1 1 1 Motor HP (Standard /Oversized) .33/.50 .33/.50 .60/.80 .60/.80 Motor RPM (Low /High Speed) 950/1,060 950/1,060 930/1,000 930/1,000 Oversized Motor RPM (Low/High Speed) 1,100/1,145 1,100/1,145 1,000/1,100 1,000/1,100 Motor Frame Size (Standard /Oversized) 48/48 48/48 48/48 48/48 Belt Drive Indoor Fan -Type - FC Centrifugal - FC Centrifugal No. Used - 1 - 1 Diameter x Width (in.) - 11 x 11 - 11 x 11 Drive Type /No. Speeds - BeltNariable Speed - BelWariable Speed No. Motors - 1 - 1 Motor HP (Standard /Oversized) - 1.00/ - - 1.00/ - Motor RPM (Standard /Oversized) - 1,750/- - 1,750/ - Motor Frame Size (Standard /Oversized) - 56/- - 56/- Filters - Type Throwaway Throwaway Throwaway Furnished? Yes Yes Yes Yes (No.) Size Recommended (in.) (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1 Refrigerant Charge (Lbs of R -22) 7.5 7.5 10.2 Throwaway (2)20x25x1 10.2 NOTES: 1, Cooling Performance and Heating Performance Is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb . Gross capacity does not include the effect of fan motor heat. ARI capacity is net and Includes the effect of fan motor heat. Units are suitable for operation to *20% of nominal cfm. Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program, which is based on ARI Standard 210/240. 2. SEER is rated at ARI conditions and In accordance with DOE test procedures. 3. Outdoor Sound Rating shown Is tested in accordance with ARI Standard 270. For more information refer to Table PD -25. 4, Refrigerant charge Is an approximate value. For a more precise value, see unit nameplate and service instructions. PKGRPRC003 -EN Table PD 28 - 4Ton Three Phase Heating Capacities (Net) WSC048A1 At 1600 CFM Outdoor Temp. F. Outdoor Temp. F Instantaneous Heating Capacity (Btuh /1000) At Indicated Indoor Dry Bulb Temp. Performance (4Ton) Data Integrated Heating Capacity (Btuh /1000) Total Power in Kilowatts At At Indicated Indoor Dry Bulb Temp.' Indicated Indoor Dry Bulb Temp. 60 70 75 80 60 70 75 80 60 70 75 80 -8 17.2 16.9 16.8 16.6 15.5 15.2 15.1 14.9 3.78 4.11 4.30 4.51 -3 19.5 19.0 18.9 18.8 17.6 17.1 17.0 16.9 3.73 4.07 4.26 4.49 2 21.8 21.3 21.1 21.0 19.6 19.2 19.0 18.9 3.82 4.14 4.34 4.55 7 24.4 23.8 23.5 23.3 22.0 21.4 21.2 21.0 3.86 4.18 4.38 4.59 12 27.0 26.3 26.0 25.8 24.3 23.7 23.4 23.2 3.90 4.23 4.43 4.63 17 29.8 29.0 28.7 28.4 26.8 26.1 25.8 25.6 3.96 4.28 4.48 4.68 22 32.7 31.8 31.4 31.1 29.4 28.6 28.3 28.0 4.01 4.34 4.53 4.74 27 35.7 34.7 34.3 33.9 32.1 31.2 30.9 30.5 4.07 4.39 4.59 4.79 32 38.8 37.7 37.3 36.8 34.9 33.9 33.6 33.1 4.13 4.46 4.65 4.85 37 41.8 40.7 40.2 39.7 37.6 36.6 36.2 35.7 4.19 4.52 4.72 4.92 42 44.9 43.8 43.2 42.7 40.4 39.4 38.9 38.4 4.26 4.60 4.79 4.99 47 48.1 46.8 46.2 45.6 48.1 46.8 46.2 45.6 4.33 4.68 4.87 5.07 52 51.3 49.9 49.2 48.6 51.3 49.9 49.2 48.6 4.42 4.76 4.95 5.15 57 54.4 52.9 52.2 51.5 54.4 52.9 52.2 51.5 4.51 4.85 5.04 5.24 62 57.5 55.9 55.1 54.3 57.5 55.9 55.1 54.3 4.60 4.95 5.14 5.34 67 57.3 55.5 54.6 53.7 57.3 55.5 54.6 53.7 4.58 4.92 5.10 5.29 72 60.5 58.5 57.6 56.7 60.5 58.5 57.6 56.7 4.70 5.04 5.22 5.42 For other airflow conditions, see heating capacity correction factor (Table PD -36). Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. NOTE: 1.Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle. Instantaneous Heating Capacity (Btuh /1000) At Indicated Indoor Dry Bulb Temp. Table PD - 4Ton Single Phase Heating Capacities (Net) WSC04a43 At 1600 CFM Integrated Heating Capacity (Btuh /1000) Total Power in Kilowatts At At Indicated Indoor Dry Bulb Temp.' Indicated Indoor Dry Bulb Temp. 60 70 75 80 60 70 75 80 60 70 75 80 -8 17.4 17.0 16.8 16.6 15.7 15.3 15.1 14.9 3.61 3.99 4.22 4.48 -3 19.5 19.1 18.8 18.6 17.6 17.2 16.9 16.7 3.57 3.96 4.20 4.48 2 21.9 21.3 21.2 21.1 19.7 19.2 19.1 19.0 3.65 4.02 4.24 4.50 7 24.3 23.7 23.5 23.4 21.9 21.3 21.2 21.1 3.69 4.05 4.27 4.52 12 27.0 26.3 26.1 25.9 24.3 23.7 23.5 23.3 3.73 4.09 4.31 4.54 17 29.7 28.9 28.7 28.5 26.7 26.0 25.8 25.7 3.78 4.14 4.35 4.58 22 32.5 31.7 31.4 31.1 29.3 28.5 28.3 28.0 3.83 4.19 4.40 4.62 27 35.5 34.6 34.3 33.9 32.0 31.1 30.9 30.5 3.89 4.24 4.45 4.67 32 38.6 37.7 37.3 36.9 34.7 33.9 33.6 33.2 3.95 4.30 4.51 4.72 37 41.7 40.7 40.2 39,8 37.5 36.6 36.2 35.8 4.01 4.37 4.57 4.78 42 44.8 43.7 43.2 42.7 40.3 39.3 38.9 38.4 4.08 4.44 4.64 4.85 47 48.0 46.8 46.3 45.7 48.0 46.8 46,3 45.7 4.16 4.52 4.72 4.93 52 51.2 49.9 49.3 48.7 51.2 49.9 49.3 48.7 4.25 4.61 4.81 5.01 57 54.4 53.0 52.3 51.7 54.4 53.0 52.3 51.7 4.35 4.71 4.90 5.10 62 57.6 56.0 55.3 54.5 57.6 56.0 55.3 54.5 4.45 4.81 5.00 5.20 67 57.4 55.7 54.8 53.9 57.4 55.7 54.8 53.9 4.45 4.79 4.97 5.16 72 60.7 58.8 57.9 57.0 60.7 58.8 57.9 57.0 4.58 4.93 5.11 5.30 For other airflow conditions, see heating capacity correction factor (Table PD -36). Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. .c . NOTE: 1. Integrated heating capacities and powers Include the effects of defrost In the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle. CC�r:: PKGRPRC003 -EN Standard Ceiling Installation Standard Inline Installation 15 flInttallations Gemini Gemini GC 100 Series ' --- The Gemini GC 100 series fans can be installed as a standard ceiling installation or as an inline installation. The fan can be converted in 7 '` the field from a standard ceiling construction to an inline construction. Airflow is illustrated by the black arrows. Standard Ceiling Installation Standard Inline Installation Gemini 200 - 2000 Ceiling and Inline Series The Gemini 200 - 2000 ceiling and inline series of fans can be installed as a standard ceiling installation or as an inline installation. The fan can be converted in the field from a standard ceiling construction to an inline construction. Airflow is illustrated by the black arrows. Shaded areas illustrate ductwork furnished by the installer. Alternate Ceiling Installation Alternate Inline Installation GC 520 1.25 1.12 a 1.00 0.88 • 0.75 5 0.62 d 0.50 0 0.38 • 0.25 0.12 0 0 GC 120 - 180 1.50 1.35 C7 1.20 1.05 c 0.90 m 0.75 d 0.60 a c+ 0.45 c / 0.30 0.15 0 GC 120 -180 60 20 0 Flow (CFM) GC 920.960 1.00 0.90 a 0.80 3 0.70 c 0.60 5 0.50 Li! • 0.40 0 0.30 c 0.20 0.10 0 0 370 75 150 225 Flow (CFM) 180 240 300 300 375 740 11 0 14801850 Flow (CFM) GC 220 -740 GC 220 -240 0.50 0.45 d 0.40 3 0.35 0.30 m 0.25 m 0.20 0 0.15 0.10 0.05 0 0 GC 620 -640 1.00 0.90 C7 0.80 3 0.70 5 0.60 5 0.50 0.40 0 0.30 co 0.20 0.10 0 0 GC 1000 1.00 0.90 C. 0.80 3 0.70 0.60 a) 0.50 d 0.40 0 0.30 • 0.20 0.10 0 30 60 90 120 150 Flow (CFM) 0 120 240 360 480 600 Flow (CFM) 470 940 1410 1880 2350 Flow (CFM) C'J c a) C) d a U CC CA GC 822 -960 GC 320-340 1.00 0.90 0.80 §. 0.70 g m 0.60 0.50 0.40 0 0.30 c�n 0.20 0.10 0 0 GC 720 - 740 1.25 1.12 1.00 0.88 0.75 5 0.62 d 0.50 0 0.38 0.25 0.12 0 0 GC 2000 1.50 1.35 1.20 1.05 0.90 0.75 0.60 0.45 0.30 0.15 16 Q 0 N 0 55 110 165 220 275 Flow (CFM) 180 360 540 720 900 Flow (CFM) 720 1440 2160 2880 3600 Flow (CFM) GC 420 1.00 0.90 0.80 0.70 4. 0.60 5 0.50 T) 0.40 0 0.30 0.20 0.10 0 0 70 0.50 0.40 0.30 0.20 0.10 0.00 00 GC 1000 -2000 GC 822 -862 1.00 0.90 0.80 C7 0.70 0.60 m a, n. U m _. Cq 300 140 2 0 280 350 Flow (CFM) 600 900 Flow (CFM) 1200 1500 Model GC Watts/ BHP RPM 0.0 SP .100 SP .125 SP .250 SP .375 SP .500 SP .625 SP .750 SP .875 SP CFM Sones CFM ISones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones 00-120 33 1200 92 1.6 77 1.7 74 1.7 50 2.2 24 2.9 7.1 1797 6.7 1566 6.6 1088 6.5 GC -140 70 1500 110 1.9 109 2.3 109 2.4 109 3.0 108 3.6 106 4.3 89 4.9 52 5.6 00-160 113 1500 154 3.3 166 3.9 168 4.0 173 5.0 171 5.1 166 5.3 156 5.5 128 5.6 .26 GC -180 192 1500 253 5.0 250 5.4 249 5.5 245 6.0 241 6.5 235 6.6 222 6.6 204 6.6 185 6.9 00-220 39 1050 120 1.2 107 1.2 104 1.1 73 1.3 2929 8.7 2734 8.6 2494 8.4 2158 8.2 .82 *1000 GC -240 65 1200 147 2.2 130 1.9 126 1.9 99 1.5 7.9 2170 7.8 1358 7.6 .59 *900 - 00-320 74.9 1365 217 4.4 205 4.1 202 4.0 182 3.8 148 3.3 .44 *800 - - GC -340 135 1610 257 4.9 237 4.5 232 4.4 212 4.3 187 4.1 00-420 170 1145 327 5.3 294 4.2 287 4.0 260 3.4 236 2.9 202 2.7 00-520 172 1205 356 5.9 347 5.7 344 5.7 332 5.5 318 5.0 301 4.6 279 4.3 249 4.0 00-620 233 960 451 3.7 433 3.3 428 3.3 400 3.3 359 3.3 297 3.6 GC -640 351 1075 559 4.6 520 4.3 512 4.3 476 4.1 429 3.9 346 3.8 00-720 301 1375 709 6.7 687 6.6 682 6.6 653 6.5 619 6.4 578 6.2 535 6.0 480 5.7 385 5.5 GC -740 374 1625 852 8.6 823 8.3 815 8.3 775 7.9 727 7.5 672 7.0 616 6.3 552 5.6 463 5.0 00-822 293 910 944 4.4 929 4.6 925 4.7 904 5.0 879 4.9 830 4.8 GC -842 380 974 1187 6.1 1157 6.2 1149 6.2 1106 6.4 1043 5.9 905 5.4 637 4.7 GC -862 450 1098 1433 8.5 1371 8.2 1355 8.1 1266 7.8 1149 6.9 995 6.1 775 5.3 GC -920 0.28 925 1471 7.6 1427 7.4 1415 7.3 1356 7.5 1286 7.7 1190 8.1 1003 8.4 00-940 0.38 1040 1653 9.1 1582 8.8 2565 8.8 1481 8.6 1400 8.4 1293 8.5 1089 8.7 GC -960 0.48 1112 1807 10.2 1716 9.7 1694 9.6 1588 9.1 1491 8.7 1386 8.6 1197 8.5 Model GC Max' watts/ BHP RPM 0.0 SP .100 SP .125 SP .250 SP .375 SP .500 SP .625 SP .750 SP .875 SP CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones GC 1000 .56 1100 - - 2231 7.8 2208 7.8 2089 7.6 1957 7.1 1797 6.7 1566 6.6 1088 6.5 .51 '1000 - - 2145 6.6 2121 6.6 1997 6.2 1856 5.8 1671 5.6 1404 5.5 .37 *900 - - 1910 5.5 1884 5.4 1740 5.0 1563 4.6 1283 4.5 .26 *800 - - 1673 4.3 1642 4.3 1470 3.7 1200 3.5 GC 2000 1.14 1140 - - 3471 9.4 3441 9.4 3282 9.3 3105 9.3 2929 8.7 2734 8.6 2494 8.4 2158 8.2 .82 *1000 - - 3081 8.6 3046 8.6 2861 8.5 2663 8.2 2448 7.9 2170 7.8 1358 7.6 .59 *900 - - 2744 7.1 2705 7.1 2489 6.9 2267 6.6 1969 6.4 1179 6.2 .44 *800 - - 2402 5.7 2356 5.7 2111 5.4 1809 5.1 1031 4.9 GC 120 - 960 Performance shown is for installation Type B: free inlet, ducted outlet. Performance ratings for GC -120 through GC -180 include the effects of inlet g ille in the airstream. Per- formance ratings for GC -220 through GC -960 include the effects of inlet grit e and backdraft damper in the airstream. Speed (RPM shown is nominal. Perfo mance is based on actual speed of the test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type B: free inlet fan sone levels. GC 1000 - 2000 Performance ratings for GC -1000 and GC -2000 is for installation Type B: free inlet, ducted outlet. Performance ratings do not Include the of ects of appurtenances In the air- stream. Speed (RPM) shown is nominal. Performance is based on actual speed of the test. The AMCA Certified Ratings Seal applies to air performance ratings only. *GC 1000 and GC 2000 RPM shown with optional FSC. 17 DEPARTMENT l✓ oz-c ) Build f f ' f ivi ion Public Works ❑ PERMIT COORD Qy PLAN REVIEW /R�l7 SLIP ACTIVITY NUMBER: M03 -092 PROJECT NAME: PACIFIC SUNWEAR SITE ADDRESS: 17340 SOUTHCENTER PY DATE: 06 -11 -03 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued 1 ( 11 -16L- Fire Prevention Q Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06 -12 -03 Complete [l Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROyTING: Please Route Structural Review Required El No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 07 -10 -03 Approved ❑ Approved with Conditions [ ( Not Approved (attach comments) El Notation: APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip,doc 2-28-02 PERMIT COORD COPY DATE: F62-052-0(8) (8/97) ' . L i F42,5-052-1)00 (1.1/97) DEPARTMENT OF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR HVAC/RFRG rVLICENSE # EXP. DATE EC6A COMFOM1004DA03/01/2004 EFFECTIVEHDATE'W '03/01/2000 COMFORT MECHANICAL INC 6617 S 193RD •PL' P105 KENT WA 98032 ' DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS :_.coNsT CONT.SPECIALTY CCAACG 'EFFECTIVE 'DATE 06/01/1999 COMFORT-MtCHANICAL INC 6617 SO 193RD PL #P-105 KENT WA 98032 - 1 • PRC lIJf SPACE NO. 17340 PARKWAY SUPER CENTER •' }1 2%7 tne VICINITY MAP TUKWLA. WAS* 4GTON KEY PLAN PARKWAY SUPER CENTER PROJECT LOCATION o mss: Namatwrr Tect4 Jour rs ., 19. 44141 I S 18001. St 2.1 af .::insfr MAP N.T.S. .y.4. 9I PARKWAY SUPER CENTER SPACE NO. X7340 17340 SOUTH CENTER PARKWAY TUKWILA, WASHINGTON 1. PROJECT NAME PACSUN 2. PROJECT DESCRIPTION:.______ — _ . CLOTHING SALES (RETAIL) a PROJECT LOCATIOIt PARKWAY SUPER CENTER 17340 SOUTH CENTER RR SPACE NO. 17340 T: }VW • PACIFIC SUNWEAR STORES CORP. 45ti LAS • M,riA_0MA .AVENUE_ ANAHEIM, CALIFORNIA 92806 -2101 (714` 414 - KIM BENNETT I•:cennett@k :_ .•csunweor.corr 4. TENANT: 5. LANDLORD 6. TENANTS ARCHITECT 7. GOVERNING a. CONSTRUCTION TYPE 9. OCCUP ANC Y• 10. GROSS LEASED PREPASES: 12. EXIT REQUIREMENTS: 13. EXIT ILLUMINATION: 14. MUMCIPAL REVEW: 15. MISCELLANEOUS NOTES: 16. FIRE SPRINKLERS: KSACO REALITY GROUP 5238 MANZAN1 TA AVE. CARMICHAEL, CALIFORNIA 95608 CONTACT: BILL ANDREWS F., NE • F) 349.7495 AAD : tttch 15425 NORTH GREENWAY- HAYDEN l JOP, SUITE #100 SCOTTSDALE. ARIZONA 85260 ?HONE: (602) 998 -4200 TAX: (602) 998 - 7223 E -MAIL: sh^ne_mc. nor * nww.com CODES: _ ALL WORK SHALL BE !N CONFORMANCE WITH, BUT NOT 'LIMITED TO. THE REQUIREMENTS OE THE FOLLOWING: AND ANY OTHER STATE AND LOCAL L DES HAVING JURISDICTION. BULDNrG: 1997 UNIFORM BUILDING CODE MECHANICAL PLUMBING: ELECTRICAL HANDICAP: ENERGY: FIRE: III -N PROJECT DATA IA (MERCANTILE) 3,909 SO. FT 11. OCCUPANT LOAD ..TOTAL NUMBER OF OCCUPANTS PUBLIC AREA: NON PUBLIC AREA: 1997 'CNiFCRM MECHANICAL CODE 1997 UNIFORM PLUMBING CODE 1999 NATIONAL ELECTRIC CODE 1998 CABO ANSI A117.1 2001 UNIFORM ENERGY CODE 199 / UNIFORM FIRE CODE = 106 TOTAL NUMBER OF EMPLOYEES AT ONE TIME = 3 3,075 S.F. _ 30 = 103 834 S.F. - 300 = 3 TWO (2) EXITS REQ., TWO (2) EXITS PROVIDED F- MFRPFNCY FXII II I UMINATION SHALI_ 9E PROVW,,FD AS SHOWN ON SHEET E2. COM9AUMTY DEVELOPMENT DEPARTMENT 6300 SOUTH CENTER BLVD_ TUKWILA. WASHINGTON 95'88 CONTACN PHONE : (206) 805 431BE.J670 LDICoTO TENANT'S CENTRAL CON T RACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXIST - LNG CONDITIONS PRIOR 7 0 START OF CONSTRUCTION AND SHALL REPORT ALL DIS- CREPANCIES TO TENANTS ARCHITECT. TENANTS GENERAL CON TRACTOR SHALL CONFORM ' O Al. L REQUIREMENTS REGARD - ING CONSTRUCTION PROCEDURES, INSURANCE, ETC.. AS SET FORTH BY THE LANDLORD. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS c YIST!NG WI THIN THIS SPACE. THE CON !RAC IOR SHALL REWORK AND MODIFY FOR NEW ROOM _AYOJT AND CEILING HEIGHTS IN CONFORMANCE WITH N .P. A. 13 STANDARDS AND LOCAL CODES & KLGULA ?IONS. ALL WORK SHALL BE DONE BY A QUALIFIED SPRINKLER CON TRACTOR WHO SHALL DESIGN AND PREPARE SHOP DRAWINGS AND SUBM T THEM TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALL- ATION. SPRNKLER CON TRAC OR SHALL BE LANDLORD APPROVED. HEADS IN CEIL'NG TILES 1 ; • __5 NR!E IN A It AREA "tiivKLLn • AD )CK ROOM. TOILET ROOMS, OFFICE & HALLWAYS: SEMI RECESSED W/ CHROME ESCUTHEONS E5 AREA: SEMI RECESSED W/ CHROME iriSCU THEONS SP3 D1 Al FLOOR PLAN A2 FIXTURE / FLOOR FINISH PLAN A3 ! REFLECTED CEILING PLAN A5 INTERIOR ELEVATIONS A6 SECTIONS AND DETAILS A7 ! SECTIONS AND DETAILS A8 SECTIONS AND DETAILS M1 I MECHANICAL PLAN M2 El E3 DEMOLITION PLAN RESPONSIBILITY SCHEDULE MECHANICAL NOTES AND SPECS. ELECTRICAL POWER PLAN E2 I ELECTRICAL LIGHTING PLAN ermIt No �. A .,_ 7 c :E�,L ,�1 p r� CNa PRIC,p OF F INDEX OF DFA vii iI GS T I TITLE SHEET Sp1 ! SPECIFICATIONS SP2 E FINISH SCHEDULES AND SPECIFICATIONS A4 ! STOREFRONT ELEVATION AND SECTIONS P1 PLUMBING PLAN, NOTES AND SPECS. ELECTRICAL SCHEDULES, DIAGRAMS AND NOTES FILE COPY urderstard trat tale Plar C oleo( approvals are Sa.c ect to errors and omissions and approval of ej1a••S does not atr:! 1 iZe the v : otattv{1 of any adopte' Cale- 7 Grot.^.3r1Ce. - (eCcat '. of con - tractor's copy of app OVed liars acknowledged. n f� (z`s J ate - 0 I SEPARATE PERMIT REQUIRED FOR: [ TECHANICAL ECTRICAL 1_0% :- JMBING AS PIPING I CITY OF TUKWILA , BUILDING DIVISION REc GITv dF . T y C' y1' ..'•9�►.'1 �" a'A Y �4'L•J"rl:•.'?. ►Yr 0o.M w ^� " At: - ?`4 Y ?!J►.• :/. I: 101 . GI• 4�^ !O -: h_. I ._ .a . . qr • • - •..1.11 S4: .- �•1.^.... ^_9'• . -. - ^ -411" _ • L ti) I C 0 di _ a tr r ay.:* CC � I 0 a.. ki in H MED UK WILA PERMIT ENTER LAIL SCAiE DRAWN ar: PROJECT No: 735 tzt z z 0 z NONE -030x. /103 -09z CS 0 -03 SHEET: I- LL LI 3 u 1 10"0 10'© /.2 350 MECHANICAL PLAN tom,; (SEA' _ l -- 4 4 (NEW, 3/4 � Ib - 4 CO '2x 4 _.� :16x b / - b 4 I ■ /1_ it ^tiE� — / - =6x6 ,� g 4 3/4' 5 G.O. i^'O'GAi./ \N :! • l 400 \ \ i } - - 2 � w ! -- - t_ -- 1 450 D',.CT SMOKE DETECTOR -I6x HEATING ONLY SETBACK THERMOSTAT 3EItYfA1Af�!sT.l fUl�(CMF.'3�' ,a F' - �{f nwY:prq SyAU`]4RfQpLf..V+f.AMIwY:�ac. K/ ASFMVC +psrti�„�lCU,2_^Ywi�.+N.:tYMx� KEYED NOTES 24X24, ;2 "4P NECK CD-i. BALANCE TO CFM NCTED. 24X24,. !0"m NECK CD-2. BALANCE TC CFi i NOTED 24x24. 22x22 NECK R6 24x24. 22x22 NECK R6 -2. T -STAT ►oRO,tDE 10`1/ CLEAR PLAST C LOCKING COVER GOORD NATE EXACT' LOCATION WITH ARCHITECTS INTER OR eLEV A T! ONS. 3/4" CONDENSATE DRA.N LINE DOWN N WALL 'O LAVATORY T.AILPILGE a "m TOILET EXHAL:ST DUCT uP T4RWu&. ROOF - O GAP LOCATE GAP 'r! IO' - O" .AWAY PROM ANY FRESH AiR NTAKES. ° :EL.D VER: F't' NEW FULL SIZE SA t RA DU'GTS DOWN THROUE-+ EX•S7 ROOT` OPENING FROM NEJA4 ROOF MOUNTED HEAT PUMP 24 HOUR ""MLCLOCK COORD 'NATE EXACT LOCATION WITW ARCH.TECT'S NTER'OR ELEVATIONS SEE "IRIN6 DIA6RAv DETAIL ON SHEET M2. NEW ROOFT0iF PACKAGED HEAT °;'NO Uy;T TO REPLACE EX ST N6 ROOFTOP °ACKA&ED AG vN' REWORK EXIST N6 EX.S7146 ' AND PROVIDE NEW GJR6 AS REQU,RED TO ACCOMMODATE NCW uN. F'ELD VERIFY ■ .. A •r - 735 • -f. Y Y ' " S-'3 XaRti<'e: F°+C'+^ "! 'J'f r _2 ? s��'M'� _ -- �K' .., .. :7:46"'. 3f iP. - - •_.__. f r.. •^.2+r r .s tor i9: .-•• - • tr_. _. -. Ftf • ••• yam r • 72, ": 'sfr _ .. 7..._. it - r' • 3 - � _ • a - _.es se+e+.f s e •• :-e s'aC f9.- • =a' r. -aaac. or 1) 41j 0 L Tr 'S. cu N t5 . to >1 2 ri C.3 g§ cc L to —se ik ,., . L#I2 UA l t. SCALE: DRAWN BV' PROJECT No. RECEIVED CITY OF TUKWILA PERMIT CENTER CS -Orf -G3 SHEET: 1/ 4= _p M 1 5 TRANE HVAC EQUIPMENT PACKAGE NIG... ^ �'• A.._ T ILANE • I AG =.. 110 +'1E\' - AA ACES :.G» AS . ' telltY •5 A.^5 !'-c . A5 9.0 'JA '4! ■4C7 SPIEL • G•• 0 0 0R .144. G 504re . i! •aR � _ = ' ' ON ON - --E °:..: = N./E -R % <ASE /E 0\4_ Az/Lc..., \-3 1°A -1 1LGK Vits.'""450 T OP4 GAS 6 'A\ TRa \s \A J\A_ AZ; == 0 �t�7 626 -5.5- - 6 D RFC- _ \° .e66 cc.- E - C__ °R=. =_ 4.726 5-2A5. E -E i =C - ==`- = -�cC . die - �c�i= v '^► r-.- i4'TC:. \= i v --� ▪ • \JET .:R / +R c \S - C = CR G \A_ =Ci_ °\- °AG<A, ' -A E - / -G =Gr 1 =YE\ - = -CAE OE_ :R_^. 5- - C ' -E A E \ C\ CC - _ ACCOr \' E. NEC- /°_ A - RA \E. \A : \A_ A\ S =\ =t . \= •�__ \G r .0 . -+ :mac °=_= ' _ _a._ _ N E - - 1 " :C \ 'T= - �R c = r=- "_ nArc�t - \-" C_ /ER" . :` \A C\ S / \E - \D \5 - A__ 1 ,^.\ =CR. A :7A - Z ✓ 5.- =YEN '- C-E _ /ER _ _R5 =R. LER - \ _:r N_ - ✓_ Gr`� =. \:\"= -A \._,_= A \✓ E\ = \:5. AARRA \'" \5=R -A\ O\= • 1 • 1 • - • • • • • IF � r ,UIPMENT PACKAGE NOTE: ORDERING PROCEDURES PARTS WARRANTIES 4 � ' E -0;.R YEG!-AN GA_ G_OGK ° '\ - _RYA_ Cu; YODEL - 24 ✓CL - FANS =CRMER • 10:.. AG T ' °OWE=c RE_ G . \\EG - C A A G \ - A \D =A \G. '.0O_ \5 A. I AC. \' T f I -; --� -.- t 1 R L = J R AC J\1T A: _\ ` SE' =AGI< P-EA \G O\�' SE'' -BACK • \6 MODE TO 60°' \ - - ERYC_ - AT WIRE .N GONYOUt" \--DOUBLE °OLE 5N6LE 'AROW .MA6\E' C CON ACTOR. A__ ,A R N.C. AND S - AR - ERS. ARE NGL.DEO \ -E C - °C G.A_ 2 / 5 ON C = _�E ° r • = GA 0\5 � __ G0\ - ••A'S ET G ARE v \DER - S ✓ _ ON WON' - ER.YCSTATS AND ;CN S,h.'GAES 5AALL E E _OGA - E^✓ AS -'OWN OR D REGTE.D, AND A__ CON - ROLS RELAYS. STARERS 1 \0 ihe N6 5i+ C_C\FORY - O - }-E NEC. A.__ GC". -ROLS Sr-A__ EE =URN S-PED C A \D PR°ERL" r„,17.4 . F'v_ �:E r„,17.4 \c'R:1G''C \5 FOR °WPER E- ECTRIGAL �OhhEG - 'C \5. RES °CNS E:I_;' =OR °4C G \NEC: "ON5 AND O°ERA - 'ON !S INCLUDED AERE \ HVAC TIMECLOCK WIRING DIAGRAM COLD CLIMATE HEATING SETBACK NTS GD -2 NEW ROOFTOP PACKAGED HEAT PUMP UNIT - S .* S'TC A__ . _ . ^ . \ ' "-'ES Ave, E\ - '�° °Qa ES a ..N- °C/*R - vER /O_TAGE 1 =-A.5-17. A DRAA \15 G.'..._ \6 G.`,� - \ v -EA A.A.:: A \D C'v AS= v \'- v ✓_' R=_a. R=._ A_ _\ s-.- /_ \C __ . ` G%+ °:.� -• S 6RC5= GC _ GA °;: ^' R° R°_ =A\ .-- �. °R,, ✓ ✓E Sc; CC = _'ER. AND = - RACsC = ZED A 500 ccv ✓E c •-. -_ - C EC O ZE - OC% °C.',AER =" S_ c= AND ,^.\.... 0 - 5� °R.. / J _ n ' GC% _ C♦ v R n ' .. _ A �'__ 7 -FRY 05 n - 5-57 E cC \ \E rc , : r -= a - - - �_ C : < =C'c == = -C< YCD _ == n R \S vs. E_- ' _ '- ✓ __ , GEL 45 D • = =.5 R R6 1 RE - .R\ SR __F. R5 -2 RE ..R\ GR _ -_ NEW EXHAUST FAN SCHEDULE B p i A emu/ A\ 7' .� ... _ .. .3- D3" ASCC r ibOC 146.4. I 'bCC ✓G °AS N:.C!.`R 5 "'K.^_ \5 CA0 600 6e-4 STEEL 23R I 57E=_ F =X 5_= DUCT M.AX. 4-- 0- ='`'`v G 5 R,C• 5?2 6 5 b e ACC line C= 3S 55. bT `GC 5:,e C 5 St G 53 2 e0 6 ? C -.c0 52e A\ 2 = NEW GRILLE, REGISTER, AND DIFFUSER SCHEDULE STEE^ I 24 x24 15 x b 1 2 x24" :25.3:x25.51 _A"- N ° =ORA "AFE_ ARC•„\D 5N466� Z ROUND 5.A RA °S °R CR - 'O \S-A,_;_• \6 2 D C.. - ACR< A_^.c'✓E \6 _:NE STRA° Ec F_AN =CR ✓- i - i- 50 I YC - CR e,.aR_ vE-r 7.7 SAC< °AN SCRD:R I 24 x24 123.5'x23.5• . -AY-IN S Z. LAY--'N i C.,E:L: \6 -- L - - - » a -∎ I -voc ..�„ - i" A'-DE x 2C GA STRA° 7, 6'TEN,N6 SC SEG.e° SSA ,' S-Ev°- ME -A_ SGREA5 a. C.G. '-Ax NOTE • S.oS 'O GONSTR.,GT ON/ BID THE CONTRACTOR V'S1 TH 5 5 AND F1ELD VESiF`' T«=E EX!ST' \6 _OGA`'ONS AND SIZES OF ANY LANDLORD °RO '/ .DED Oct =_X;5'; \G. OUTS'•DE AIR INTAKES _- RO,rG+. ROOF, _AND_ORD °ROV,DED AA �R P' °, \6 MA \5 TO LE EXHAUST MANS, O;rTS!D! A R DUG'AOR< CONDENSA'°_ _ NE YA NS. ETC. �J. - TyE CONTRACTOR 5AALL j ° !ELD VERIFY ANY/ GOND "IONS AHICH MAY GONRL,GT "'tn. : APE DESIGN Si -'OWN ON - ESE PLANS. NOT'F`'' A RCHIT C M'NED;AT=' " 4.-AA`s' Et-ADE c P°c5C_D CS A C•w 1 . 5- NON= °AR S'E =.. 24 x24 23.' x25 c ..A" -N ° =_R =ORA • NONE 24"x24.' "77 7 .',5" MODE_ # T^JC. ROUND NECK (SE_E °OR NECK a;,. =. BORD =R - ` ^OE 3- LA`'' -!N D :F' = ✓SES VT.S SQUARE SUPPLY AIR DIFFUSER DETAIL MECHANICAL GENERAL NOTES A- "CR.< S-& _ Gr #'- =�__ *�_ .1a • -s c . AND _•i\^_' SOS GR r=at - - GCvo_s - rC - a_.. - SE •. A O - Gya_sc S'A •ARE= CF yYrC "SA Gs - 5 err - �, N.4 \. =aa. - _S.S S S-R C R. :,: \:. +- O'\. ' :R .w. °YE\ AND °R ✓ - T -■ G:�\C�: C4 = -'''__ . - \ A\✓ °i"' ¢;iR, A_,._ °E'Rv' _ DOG. \`S AND SEE : .:LE5 R=_A 7 0 \5 - A__r* 0\ C. .. nC'R< - °R ;; C 7 =.. Y -- sA5 A ° . ^ i SA-. - -'f v i\ AC 5-A- f S - - ...s s - E AND =x \G cc\=. - c\s - c s�,RE -_�- -- ^CR.< 55 q°_Sa \ :.♦ - -R DR.an \65 A \D \ - .Icc! gab : ° \ ONS C.. AN e_ \S ►_ -_:i A = \:i E - ' .� c G. _�_ - =D \ ,,,_ :R.. A As-R.-az :►\D _-•�_- :v ^� \-� _` - \� -eD= =RC/ D= - .e\ \5 / -\ S \ A__ a_Ec,S A\: ..AN-A_ /.^._,Y_ :A °ERS __- - \ __ __ __ °=R O:,v ° =R= F - "C-A_ SRS =\ RA.; - :mac: -i: S v_AS .r/ / \5 ;55S -S -: °S :O °R SA \Gc_ A O. E - A D �_ _ g:5 O°C_S- c4„ ✓ 6 7.7_C - nCR< . -A-- E'_` /o\ ZJ �- 'E A_ : _ i�< =CRY NS 0, A._ n -- _ /a = ASS =R A i V 5 A \O _= -v5 S -A -- 3 S34_1 \ A vA \ \ER - C °RC - / C= A ✓A °�R` S - E\G_CS.R°_ 3 {.6= .° =C _- = .5= . SC AND C'./..EN == e:.- eC .\: GA_ /+. Z =:7 v_ A_ D. nCSc< r -- - -- G< = 55S5_455' \S._A C\ n -- =C _ / °^.R =ASS °_R A_ _C \ AND SEAYS 5^A-- 5= 5=A_ED i A YA\NER - C °RC / OE -> G _ - /A °CR 6 - E \G_CS.RE 2 GAGE .° -^. Sc - D.D. SA-GE-56 - C Sc F'FS _ _- c= :..G =RCY .:r °v=\ _ ^A__ =a _ \E_ AGO�S GA _ N_. - ON F- = Dc \S - =_=N 3_: C nOR< 5-A-- 5E - _`S''A -_Ex V -'tS , - c\E NA_ \54. -A -- A : = °c4 EASS _ - iC =C _- - :• _° ° A -- J A`d° -_ ti : - CS A. NZ.; C RC CC ___ AR ., ^ _ J = =r3ER = __x 5_. D -,cS< E -A -- \:. = XG__:. = -__= \ =-A -- \C sss s C \S ✓= �ec=s - 0\ -._ .- SE- 0\ s __ _ 2. REL - S =cs_ e_= • - = v,� • s.�= .A__ ncR< S -A -- 5° LcGA'=D - 0 A. iC D CON._ G - S A -- O - RADE5 °RC / J . 4:73, l.a'' C__ARANGE =C.R •R.C.A: .RA_ J=5 -r5 N °R CF=e C°°RA cN A\17 5.ER'/ C=_ .0= !O. °Y'=\• C FRC / DE A RE AD" 'C -rss SYS''� rr1 :. A AcR< 5.ARA•. =_D \ AFC - 71 -'N6 AGA \S- Dsz =cG_. /e, ACR<YA \S- ° AND Ya - : _'_5 =CR. A °°_R OD G= ONE YEAS =ROY - .RN OVER Tc CANER CONDENSA'75 AND GCC_SR. 174A \s: - von v -AR-17 OR.AAN GO = �R L NES : AND SMAL_ER Dihv -ARD DR-A/\\ :C°C =_R =CR - - AN--; -C J SA \46E -v°_ =CR _ NE5 ' - +/4 AND -AR✓ R. SC -DES A -- 50_2=R 2. DUC - ACR< St'-A__ BE • °ALTORY YADE : _ASS :SA_ ✓.A\ .:ED 5•.E = v= - rte ihr7 'RON 5UPFCR 75 SEG .RED -C O• /E+.t -E_.AD YENA `RS A _ -0" D':.GTAORK MA'BR.ArB S -Ai__ 5.7. °ER AOCQ\D'X r . Y c aa4 3. °R.^.V JE AS =PART OF TAE yaciAAN c4_ A R '/v.\'.R 54._ANGIN6 coNTRAGTOR G °_R _ =D S `-__ • ASscC' °> SA_ANG °_ GOO 55 = - O A_A \G° Z °cR 'C ASS- • - 5-f- -- CANER °ROV •DE :.G SYCKE :ETEG - ORS N SA DUCTS. - 0 OVER R DE .N ' AND °RCV•DE 5-. O,hN AAE.N UPON DE-Ec- CN c= :YOKE. .. • .0 1041:. ;ft1 ^ ]t fit..' ..Q34 _• O. Gf Z c cu u0 I..= kr ca r iv; >, 11 u '� I z 5,71)2 W D � J W < LU I. C/3 4 735 0 DAP SCALE: DRAWN BY PROJECT No • • RECEIVED CITY or TUKWILA PERMIT CENTER . E 3 43 O c5- c,._c3 SHEET. N - 5. -p,: M2 HVAC NOTES 2. 3 5 6 -. S. A_._ AOR< - O ^E A5 °ER ^+E :r.� 5FEG5 A,_i_. _OGA- CODES. R;r� =• A\:. REGt.LA •'DNS ALL AOC< TO BE AS °QS ASr. A_= AND SMAG \A 6L :.E_'\ES. A...'- DUC.7 5'ZES 5+-CFFN ARE C.-EAR NE,DE. A._ DUG - S '0 SE S-E = YE D`.G - 5 AS •OR A5 -RAE A\:. SYAG\A GLIDE_ •\E5 °RCV :.E \EGESSAR' 7 .RN. \6 ' ✓A. \E5 5 - ^'R 2-AM ° =R5. JC_:.'E = XTRAG - OR5. AND C7 F_A ORES NEEDED =OR A 5•1OO7- A\:. CON =LOA OF A R LOCAT'CNS 5-CAN OF -+V.AC ECtt. °YE\- AND :.UGTS ARE 5.CAE)'A G ONLY :'ER;C" STRuGTLRAL :7E7AuL.5 .AND OT -ER :.E'A _S '' ^ A,- AFFEG SOL, \5 AND 0 - AC5:N C7'- "ESE COMPONENTS. is YORE 51..0°0R - 5 ARE NEED°' ¢O• -` /AC, E .. °Y°_N- COCRD;NA - E W;,-- ''-E ASC -,'F :" °RC' ✓ WFS °E :�LGT TRANS+= =CR. Ac:'''_AL. -VAC . \. 'NS --.ED ROOF PENE -RA OHS, F ANY, TO BE MADE AS °Esc _._. SO°_C S VER..r" DE'A _5 /Y■ - - ._.. Pte.` / D E. 4N1D INSTA -L T+..E4MC5 - A S A- _OGA7..O,� A5 D RCG - 'ED BY - - , 1= ARG -''G- GCORD HATE ACT.AL LOCAT'ONS OF D -SER5 RE& S"'=e5 \D GR L-5-5 5 n T- GEL \G DE - A , _5 AND CT -ER =EA".R.ES SUG- AS ._ S-- N5 F x -.RES - r. '-+A' YAY AFC=-C PLAGEYE\' C= - -E -,VAC SYSTEM G0'r'PCNE \TS. GENERA-. GON'RAGTOR S-A_... 5UP°LY AL- =oU °M_\- CCNTRCLS A\D n R :N6. COORD. \ATE h,n.4 YA;_,.. RE ° RESE\TA`'✓E FOR ;LATER- OG<: \6 ,h,T ■ YR.,- CONTRO_ SYS "EY i'A5 RECi,''RE:.1 DUCTWORK SYMBOLS S N6_E DOUi3__ ABBR DEsGR °- ON • REG7Ati6V_AR ,,CT *- - ---,' s s Y a • ROL:ND DUCT - i 4 • • 45 DE6 TAP- USE AT BRANCH DUC - = ONLY - 4 \1 + 4- t - 9 -4----- + - i - ! e . • DUG,. 3PL '. IW17AMj E .:3E AT ELHOWL AND - EES: °RC °CRT DUCT AREAS ?`� GF`M'S • G JRV°-D E1.SOW -Y N RAD L5 R 5 W!DT;•+ - -- y -� 4- - . 4- 1 • V DE6. ELBOW Ai?r- SN6LE RADIUS TURNING VAS - • j°LEXIBLE "DUCT C.ONNEGT'ON 'r- 111111 -'r 1 a I FD P!RE DAMIFER 7 ( ` BALANCING DAHpF-R ( -5E 0 B D. UNLESS 8D NOTED OTHERhIsE) ;, \EW TO EXISTING CONNEECT:ON ll • 50!N -IN FLEX DUO" TAKE -000 A/DAM0ER 7 r e {l.�I 5A i 51.0 AIR e Z r XH EXHAUST AIR • Z RA RETURN A R • REL.. I RELIEF" AIR • - .i _____ 2. , 147411 ; OSA OUTSIDE AIR • (T) LC 1 Tt+ERMOSTAT X: JN,T OR ZONE NU*fBER • �TJ1 X T 71 -+ERMO5TAT ■/SHERWOOD GUARD TRANE HVAC EQUIPMENT PACKAGE NIG... ^ �'• A.._ T ILANE • I AG =.. 110 +'1E\' - AA ACES :.G» AS . ' telltY •5 A.^5 !'-c . A5 9.0 'JA '4! ■4C7 SPIEL • G•• 0 0 0R .144. G 504re . i! •aR � _ = ' ' ON ON - --E °:..: = N./E -R % <ASE /E 0\4_ Az/Lc..., \-3 1°A -1 1LGK Vits.'""450 T OP4 GAS 6 'A\ TRa \s \A J\A_ AZ; == 0 �t�7 626 -5.5- - 6 D RFC- _ \° .e66 cc.- E - C__ °R=. =_ 4.726 5-2A5. E -E i =C - ==`- = -�cC . die - �c�i= v '^► r-.- i4'TC:. \= i v --� ▪ • \JET .:R / +R c \S - C = CR G \A_ =Ci_ °\- °AG<A, ' -A E - / -G =Gr 1 =YE\ - = -CAE OE_ :R_^. 5- - C ' -E A E \ C\ CC - _ ACCOr \' E. NEC- /°_ A - RA \E. \A : \A_ A\ S =\ =t . \= •�__ \G r .0 . -+ :mac °=_= ' _ _a._ _ N E - - 1 " :C \ 'T= - �R c = r=- "_ nArc�t - \-" C_ /ER" . :` \A C\ S / \E - \D \5 - A__ 1 ,^.\ =CR. A :7A - Z ✓ 5.- =YEN '- C-E _ /ER _ _R5 =R. LER - \ _:r N_ - ✓_ Gr`� =. \:\"= -A \._,_= A \✓ E\ = \:5. AARRA \'" \5=R -A\ O\= • 1 • 1 • - • • • • • IF � r ,UIPMENT PACKAGE NOTE: ORDERING PROCEDURES PARTS WARRANTIES 4 � ' E -0;.R YEG!-AN GA_ G_OGK ° '\ - _RYA_ Cu; YODEL - 24 ✓CL - FANS =CRMER • 10:.. AG T ' °OWE=c RE_ G . \\EG - C A A G \ - A \D =A \G. '.0O_ \5 A. I AC. \' T f I -; --� -.- t 1 R L = J R AC J\1T A: _\ ` SE' =AGI< P-EA \G O\�' SE'' -BACK • \6 MODE TO 60°' \ - - ERYC_ - AT WIRE .N GONYOUt" \--DOUBLE °OLE 5N6LE 'AROW .MA6\E' C CON ACTOR. A__ ,A R N.C. AND S - AR - ERS. ARE NGL.DEO \ -E C - °C G.A_ 2 / 5 ON C = _�E ° r • = GA 0\5 � __ G0\ - ••A'S ET G ARE v \DER - S ✓ _ ON WON' - ER.YCSTATS AND ;CN S,h.'GAES 5AALL E E _OGA - E^✓ AS -'OWN OR D REGTE.D, AND A__ CON - ROLS RELAYS. STARERS 1 \0 ihe N6 5i+ C_C\FORY - O - }-E NEC. A.__ GC". -ROLS Sr-A__ EE =URN S-PED C A \D PR°ERL" r„,17.4 . F'v_ �:E r„,17.4 \c'R:1G''C \5 FOR °WPER E- ECTRIGAL �OhhEG - 'C \5. RES °CNS E:I_;' =OR °4C G \NEC: "ON5 AND O°ERA - 'ON !S INCLUDED AERE \ HVAC TIMECLOCK WIRING DIAGRAM COLD CLIMATE HEATING SETBACK NTS GD -2 NEW ROOFTOP PACKAGED HEAT PUMP UNIT - S .* S'TC A__ . _ . ^ . \ ' "-'ES Ave, E\ - '�° °Qa ES a ..N- °C/*R - vER /O_TAGE 1 =-A.5-17. A DRAA \15 G.'..._ \6 G.`,� - \ v -EA A.A.:: A \D C'v AS= v \'- v ✓_' R=_a. R=._ A_ _\ s-.- /_ \C __ . ` G%+ °:.� -• S 6RC5= GC _ GA °;: ^' R° R°_ =A\ .-- �. °R,, ✓ ✓E Sc; CC = _'ER. AND = - RACsC = ZED A 500 ccv ✓E c •-. -_ - C EC O ZE - OC% °C.',AER =" S_ c= AND ,^.\.... 0 - 5� °R.. / J _ n ' GC% _ C♦ v R n ' .. _ A �'__ 7 -FRY 05 n - 5-57 E cC \ \E rc , : r -= a - - - �_ C : < =C'c == = -C< YCD _ == n R \S vs. E_- ' _ '- ✓ __ , GEL 45 D • = =.5 R R6 1 RE - .R\ SR __F. R5 -2 RE ..R\ GR _ -_ NEW EXHAUST FAN SCHEDULE B p i A emu/ A\ 7' .� ... _ .. .3- D3" ASCC r ibOC 146.4. I 'bCC ✓G °AS N:.C!.`R 5 "'K.^_ \5 CA0 600 6e-4 STEEL 23R I 57E=_ F =X 5_= DUCT M.AX. 4-- 0- ='`'`v G 5 R,C• 5?2 6 5 b e ACC line C= 3S 55. bT `GC 5:,e C 5 St G 53 2 e0 6 ? C -.c0 52e A\ 2 = NEW GRILLE, REGISTER, AND DIFFUSER SCHEDULE STEE^ I 24 x24 15 x b 1 2 x24" :25.3:x25.51 _A"- N ° =ORA "AFE_ ARC•„\D 5N466� Z ROUND 5.A RA °S °R CR - 'O \S-A,_;_• \6 2 D C.. - ACR< A_^.c'✓E \6 _:NE STRA° Ec F_AN =CR ✓- i - i- 50 I YC - CR e,.aR_ vE-r 7.7 SAC< °AN SCRD:R I 24 x24 123.5'x23.5• . -AY-IN S Z. LAY--'N i C.,E:L: \6 -- L - - - » a -∎ I -voc ..�„ - i" A'-DE x 2C GA STRA° 7, 6'TEN,N6 SC SEG.e° SSA ,' S-Ev°- ME -A_ SGREA5 a. C.G. '-Ax NOTE • S.oS 'O GONSTR.,GT ON/ BID THE CONTRACTOR V'S1 TH 5 5 AND F1ELD VESiF`' T«=E EX!ST' \6 _OGA`'ONS AND SIZES OF ANY LANDLORD °RO '/ .DED Oct =_X;5'; \G. OUTS'•DE AIR INTAKES _- RO,rG+. ROOF, _AND_ORD °ROV,DED AA �R P' °, \6 MA \5 TO LE EXHAUST MANS, O;rTS!D! A R DUG'AOR< CONDENSA'°_ _ NE YA NS. ETC. �J. - TyE CONTRACTOR 5AALL j ° !ELD VERIFY ANY/ GOND "IONS AHICH MAY GONRL,GT "'tn. : APE DESIGN Si -'OWN ON - ESE PLANS. NOT'F`'' A RCHIT C M'NED;AT=' " 4.-AA`s' Et-ADE c P°c5C_D CS A C•w 1 . 5- NON= °AR S'E =.. 24 x24 23.' x25 c ..A" -N ° =_R =ORA • NONE 24"x24.' "77 7 .',5" MODE_ # T^JC. ROUND NECK (SE_E °OR NECK a;,. =. BORD =R - ` ^OE 3- LA`'' -!N D :F' = ✓SES VT.S SQUARE SUPPLY AIR DIFFUSER DETAIL MECHANICAL GENERAL NOTES A- "CR.< S-& _ Gr #'- =�__ *�_ .1a • -s c . AND _•i\^_' SOS GR r=at - - GCvo_s - rC - a_.. - SE •. A O - Gya_sc S'A •ARE= CF yYrC "SA Gs - 5 err - �, N.4 \. =aa. - _S.S S S-R C R. :,: \:. +- O'\. ' :R .w. °YE\ AND °R ✓ - T -■ G:�\C�: C4 = -'''__ . - \ A\✓ °i"' ¢;iR, A_,._ °E'Rv' _ DOG. \`S AND SEE : .:LE5 R=_A 7 0 \5 - A__r* 0\ C. .. nC'R< - °R ;; C 7 =.. Y -- sA5 A ° . ^ i SA-. - -'f v i\ AC 5-A- f S - - ...s s - E AND =x \G cc\=. - c\s - c s�,RE -_�- -- ^CR.< 55 q°_Sa \ :.♦ - -R DR.an \65 A \D \ - .Icc! gab : ° \ ONS C.. AN e_ \S ►_ -_:i A = \:i E - ' .� c G. _�_ - =D \ ,,,_ :R.. A As-R.-az :►\D _-•�_- :v ^� \-� _` - \� -eD= =RC/ D= - .e\ \5 / -\ S \ A__ a_Ec,S A\: ..AN-A_ /.^._,Y_ :A °ERS __- - \ __ __ __ °=R O:,v ° =R= F - "C-A_ SRS =\ RA.; - :mac: -i: S v_AS .r/ / \5 ;55S -S -: °S :O °R SA \Gc_ A O. E - A D �_ _ g:5 O°C_S- c4„ ✓ 6 7.7_C - nCR< . -A-- E'_` /o\ ZJ �- 'E A_ : _ i�< =CRY NS 0, A._ n -- _ /a = ASS =R A i V 5 A \O _= -v5 S -A -- 3 S34_1 \ A vA \ \ER - C °RC - / C= A ✓A °�R` S - E\G_CS.R°_ 3 {.6= .° =C _- = .5= . SC AND C'./..EN == e:.- eC .\: GA_ /+. Z =:7 v_ A_ D. nCSc< r -- - -- G< = 55S5_455' \S._A C\ n -- =C _ / °^.R =ASS °_R A_ _C \ AND SEAYS 5^A-- 5= 5=A_ED i A YA\NER - C °RC / OE -> G _ - /A °CR 6 - E \G_CS.RE 2 GAGE .° -^. Sc - D.D. SA-GE-56 - C Sc F'FS _ _- c= :..G =RCY .:r °v=\ _ ^A__ =a _ \E_ AGO�S GA _ N_. - ON F- = Dc \S - =_=N 3_: C nOR< 5-A-- 5E - _`S''A -_Ex V -'tS , - c\E NA_ \54. -A -- A : = °c4 EASS _ - iC =C _- - :• _° ° A -- J A`d° -_ ti : - CS A. NZ.; C RC CC ___ AR ., ^ _ J = =r3ER = __x 5_. D -,cS< E -A -- \:. = XG__:. = -__= \ =-A -- \C sss s C \S ✓= �ec=s - 0\ -._ .- SE- 0\ s __ _ 2. REL - S =cs_ e_= • - = v,� • s.�= .A__ ncR< S -A -- 5° LcGA'=D - 0 A. iC D CON._ G - S A -- O - RADE5 °RC / J . 4:73, l.a'' C__ARANGE =C.R •R.C.A: .RA_ J=5 -r5 N °R CF=e C°°RA cN A\17 5.ER'/ C=_ .0= !O. °Y'=\• C FRC / DE A RE AD" 'C -rss SYS''� rr1 :. A AcR< 5.ARA•. =_D \ AFC - 71 -'N6 AGA \S- Dsz =cG_. /e, ACR<YA \S- ° AND Ya - : _'_5 =CR. A °°_R OD G= ONE YEAS =ROY - .RN OVER Tc CANER CONDENSA'75 AND GCC_SR. 174A \s: - von v -AR-17 OR.AAN GO = �R L NES : AND SMAL_ER Dihv -ARD DR-A/\\ :C°C =_R =CR - - AN--; -C J SA \46E -v°_ =CR _ NE5 ' - +/4 AND -AR✓ R. SC -DES A -- 50_2=R 2. DUC - ACR< St'-A__ BE • °ALTORY YADE : _ASS :SA_ ✓.A\ .:ED 5•.E = v= - rte ihr7 'RON 5UPFCR 75 SEG .RED -C O• /E+.t -E_.AD YENA `RS A _ -0" D':.GTAORK MA'BR.ArB S -Ai__ 5.7. °ER AOCQ\D'X r . Y c aa4 3. °R.^.V JE AS =PART OF TAE yaciAAN c4_ A R '/v.\'.R 54._ANGIN6 coNTRAGTOR G °_R _ =D S `-__ • ASscC' °> SA_ANG °_ GOO 55 = - O A_A \G° Z °cR 'C ASS- • - 5-f- -- CANER °ROV •DE :.G SYCKE :ETEG - ORS N SA DUCTS. - 0 OVER R DE .N ' AND °RCV•DE 5-. O,hN AAE.N UPON DE-Ec- CN c= :YOKE. .. • .0 1041:. ;ft1 ^ ]t fit..' ..Q34 _• O. Gf Z c cu u0 I..= kr ca r iv; >, 11 u '� I z 5,71)2 W D � J W < LU I. C/3 4 735 0 DAP SCALE: DRAWN BY PROJECT No • • RECEIVED CITY or TUKWILA PERMIT CENTER . E 3 43 O c5- c,._c3 SHEET. N - 5. -p,: M2