Loading...
HomeMy WebLinkAboutPermit M03-126 - SOUTHCENTER MALL - ZUMIEZM03 -126 Zumiez 1008 Southcenter Mall Z — O 0 W W; W W 0' S2 a • W` =. Z�.., F- O: W� U• � co 'O H`. W - U W` -O w Z U= O Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Signatur : doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049004 Address: 1008 SOUTHCENTER MALL TUKW Suite No: Permit Center Authorized Signature: • Print Name: < vNit_ • ZUMIEZ 1008 SOUTHCENTER MALL, TUKWILA WA 3G SOUTHCENTER LTD 25425 CENTER RIDGE RD, CLEVELAND OH DAVID MURPHY 2101 NINTH AV, SUITE 211, SEATTLE WA Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109, REDMOND, WA Contractor License No: MERITMI163CM DESCRIPTION OF WORK: REMOVING EXISTING DUCTWORK AND REPLACING WITH NEW DUCTWORK. EXISTING HEAT PUMP TO REMAIN Value of Construction: $8,000.00 Type of Fire Protection: N/A MECHANICAL PERMIT Fees Collected: Uniform Mechnical Code Edition: M03 -126 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 341 -9875 Phone: 425 883 -9224 Expiration Date:06 /01/2005 M03 -126 10/13/2003 04/10/2004 $63.63 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: / 0 - / 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 10 -13 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS z • w Fx 2 6 v 00 u) 0 CO UJ J H w 2 u . w z �. 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any z O construction. These documents are to be maintained and available until final inspection approval is granted. uj U� O � off 111 u 6: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 H v Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). u O ti.i Z U O Parcel No.: 2623049004 Permit Number: M03 -126 Address: 1008 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 08/01/2003 Tenant: ZUMIEZ Issue Date: 10/13/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 8: Manufacturers installation instructions required on site for the building inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: JoH h 2--(`v, doc: Conditions M03 -126 Date: /D —/, 3 —62 Printed: 10 -13 -2003 z CITY OF TUKWILA -_ Community Development . dartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 10013 'p-r 1, 1A4C-r �� [ Tenant Name: Zu,►,4te2. Property Owners Name: WrierL.'I7 Mailing Address: ll(QOL UJt IhHIR -6 elDU1.0 U 1'7 ' -FLPQV.- 1,05 kz6tt,ES CA ct00 zS City t State ( Zip Name: Contact Person: E -Mail Address: Contractor Registration Number: -17,4mfl '3 Mu Mailing Address: 21 `- E -Mail Address:Ai/Mir tl't1uslAlty Cew4 GENERAL CONTRACTOR INFORMATION AAA Public Works Permit No. Project No. King Co Assessor's Tax No.: ce Suite Number: Floor: New Tenant: .... Yes 1 0 ..No Day Telephone: 0200 €4 1 "" T S/5 tk14 Xe' 121 City Fax Number:C20(9) 34 (-- - l 1 -11 State Zip Company Name: Q, Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mu,Y tr lt� { Va. Mailing Address: '2-10 ( l N, ctt+ 7.1\ Contact Person: t2,Aela Ntti'F -rK- E -Mail Address: Avvturrtu MU v Vfey t C Y1'2A Company Name: Mailing Address: jSI&A. a4, N1C. Contact Person: ', '" 'fvTt -% E -Mail Address: Cb k7eAlirA C, IrvaN71St S applications \permit application (3-2003) 3 /2003 Page 1 • i Z City State Zip Day Telephone('2 ) �44 - cicfsig Fax Number: (2c,) 3M1 -61k '( 1 ENGINEER OF RECORD - All plans must be wet stamped by Engineer, of Record , e - 2.- vi. t- W cASIO 1 City Slate Zip Day Telephone: 20(0 4fFj - 3 3Z (o Fax Number: 20(9 - 4-4 5 445° BUILDING PERMIT INFORMATION -- 20-431-361U Valuation of Project (contractor's bid price). Existing Bu .g Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes .. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single- family building footprint (arca of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑..Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0.. Yes ❑ ..No If "yes". attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantifies and Material Safety Data Sheets. \applicationatpermit application (3.2003) 3/2003 Page 2 Compact: Handicap: Existing Interior Remodel Addition to Existing Structure New Type of . Construction per UBC Type of Occupancy per UBC 1" Floor • 2n Floor • 3 " Floor Floors thru • Basement Accessory Structure* Attached Garage • ' • Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION -- 20-431-361U Valuation of Project (contractor's bid price). Existing Bu .g Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes .. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single- family building footprint (arca of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑..Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0.. Yes ❑ ..No If "yes". attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantifies and Material Safety Data Sheets. \applicationatpermit application (3.2003) 3/2003 Page 2 Compact: Handicap: I :PUBLIC WORKS PERMIT INFORMATION - 206 - 433 -0179 Scope of Work (please provide detailed in. nation): Water District ❑...Tukwila 0... Water District #125 ❑... Water Availability Provided Sewer District ❑...Tukwila 0... ValVue ❑ .. Renton ❑...Seattle ❑...Sewer Use Certificate ❑ ... Sewer Availability Provided ❑ .. Approved Septic Plans,Provided ❑...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") .. .Technical Information Report (Storm Drainage) .. .Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): .. .Right -of -way Use - Nonprofit for Tess than 72 hours 0 .. Right -of -way Use - Profit for less than 72 hours 0 ...Right -of -way Use - No Disturbance ❑ .. Right -of -way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way [...Total Cut [...Total Fill 0...Sanitary Side Sewer ❑...Cap or Remove Utilities ❑...Frontage Improvements [...Traffic Control 0 ...Backflow Prevention - Fire Protection Irrigation Domestic Water .. .Permanent Water Meter Size... ❑...Temporary Water Meter Size.. ❑...Water Only Meter Size ❑ ...Sewer Main Extension Public _ 0 ...Water Main Extension Public bpptiuHOnsVennit spphcawn (3.2003) 3/2003 Please refer to Public Works Bulletin #1 for fees and estimate sheet, cubic yards cubic yards I v It .. • Abandon Septic Tank .. Curb Cut .. • Pavement Cut .. • Looped Fire Line Call before you Dig: 1 -800- 424 -5555 WON WON WON Private Private 0 .. Highline ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless .. • Work in Flood Zone .. • Storm Drainage Page 3 ❑ ...Renton ❑ .. Grease Interceptor 0 .. Channelization .. • Trench Excavation .. • Utility Undergrounding 0 ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑...Water ❑...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) 0 ... Sewage Treatment Day Telephone: City Day Telephone: City State . State Zip Zip • C4 2 W 0 N N W - CO u- W � 2 a W Z ± 0 Z t' W UCI O 0 1— W W HU LL ~O .. Z W U = O Z Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler 3 -15 HP /500.000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1.000,000 BTU Suspended /Wall /Floor Mounted Heater - Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ IIP /1,750.000 BTU Heat/Refrig /Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind MECHANICAL PERMIT INFOR tkTION — 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: 7 a z Indicate type of mechanical work being installed and the quantity below: City State Zip Day Telephone: Fax Number: Contractor Registration Number: Expiration Date: **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price). $ ei(JerD Scope of Work (please provide detailed information): 12.61/bt6(ifr) . (1041 Ja.k hn. OT t°�15T1 Tee (21 W 6 7) 1440 V. hew 2t,y4n:p2 Ik - ref6C. "`J t.0 Vivo) ) atm:A000Y k . ct rr� -�(��l TuAuts Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas ....0 Other: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. 1 HEREBY CER PENALTY OF PE BUILDING OWN Signature: Date: 7/5//zoo 7� Day Telephone:( ) 5 ,- 611 15 Mailing Address: 24 O I Mt N A‘) E.. \ � C1. 1 City State Zip Print Name: Date Application Accepted: r /' Date Application Expires: Staff Initi s: \applications%permit application (3.200)) 31200) THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER BY THE LAWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 0 AGENT: -pis tp L4u9 ' Y Page 4 Receipt No.: R03 -01243 Initials: SKS User ID: 1165 ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049004 Permit Number: M03 -126 Address: 1008 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 08/01/2003 Applicant: ZUMIEZ Issue Date: Payee: MERIT MECHANICAL INC TRANSACTION LIST: Type Method Description Amount Payment Check 20876 MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Payment Amount: 63.63 Payment Date: 10/13/2003 10:18 AM Balance: $0.00 63.63 Account Code Current Pmts 000/322.100 50.90 000/345.830 12.73 Total: 63.63 3631 10/14 9716 TOTAL 63.63 Printed: 10 -13 -2003 Prow: /1 kr A c 7...- Type of Inspection: 1J le I S Au-ielowai Address: 1 0 0 4 S S owl ivien1.40, M411 Date Called: Special Instructions: A- D r /4 u4e Date Wanted: a.m. P.m. Requester: Phone No: Li 2 S" - 4 -2 eZ 3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 \IR( Approved per applicable codes. El Corrections required prior to approval. COMMENTS: -vyN-3)4- SL- cQ Ins ector: 1 R ceipt No.: INSPECTION RECORD Retain a copy with permit e-"A AJ yr) o 3 Date: ) O 7- s $47.00 REINSPECTION EE REQUIRED. Pri r to inspection, fee must be paid at 6300 Southcente Blvd., Suite 100. all to schedule reinspection. Date: , •—• • - ... • • .. Project: Type of Inspection: Address: �r,t1 i. , II, Date Called: /0- i4 Special Instructions: ie L(.tG4£G/ Date VP anted: 1i) r /5.-03 p. m. Requester Phone No: X f 6•- 442-2z1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit A/O -1t PERMIT NO. El Approved per applicable codes. Corrections required prior to approval. COMMENTS: I Date: /b - /S O S47.00 REINSPECTI N FEE REQUIREq! to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 00. Call to schedule relnspection. Receipt No.: Date: Proje Type of spection: Addr ess / O LSD M� Dafe alled: /C� — /.3 —d Special Instructions: 7� �ZQ `-� $& / 0 A /j C i �" �O.SS /ALE 1 Date Wanted: J, /� '.� `r r U� a.m. P. m . te Requ r: j Phon(4/02 -- f 7" 0 o G INSPECTION RECORD Retain a copy with permit .INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. I ►i' $47.00 REINSPECTION F E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. orrections required prior to approval. COM EN TS: 1 /ice & �- 7 /d?' 'Receipt No.: 'Date: ' h .1. �� f . "r- 4��• t; . � �. r . t r.+. $.,ry'�- �'�,,�"- :.r....::�rv.Y �a., �-� t ,.. � TRH `tin�q "^—rm'' '�a`,' S ;F Project Name Z )h ►-P 7.. Address . /003 So h r r. (t.- / / City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Needs shift inspection TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current-, inspection .schedule Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: APO -x // :Authorized Signature Date FINALAPP.FRM Steven M. Mullet, Mayor Permit No. D03 , Mc) - %z Suite # Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East, • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M03 -126 PROJECT NAME: ZUMIEZ SITE ADDRESS: 1008 SOUTHCENTER MALL X Original Plan Submittal _ Response to Correction Letter # DATE: 08 -04 -03 Response to Incomplete Letter # Revision # After permit Is Issued DEPARTMENT 0 -51 57/ ilk_ g 4-a3 Building Division © Fire Prevention 0 Public Works ❑ Structural ❑ REVIEWER'S INITIALS: Documents /routing slip.doc 2 -28 -02 Planning Division Permit Coordinator DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08 -05 -03 Complete E Incomplete Com P P ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R9UTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 09 -02 -03 0 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: r F625. 052.000 (8/97) • Notary Public in and for the State of Washington residing in Redmond. sad Detach And Display Certificate DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST.CONT GENERAL EXP... ;CCO1 :'MERITMI163CM 06/01/20,0,5: ``EFFECTIVE DATE ' MERIT MECHANICAL INC PO BOX 2109 REDMOND WA 98073 -2109 Detach And Display Certificate I certify that this is a true and correct copy of an original license. — -1 WORK FURNISHED AND /OR INSTALLED BY OTHERS THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING ALL THE WORK EXCEPT AS NOTED. PORTIONS OF THE PROJECT WILL BE CONTRACTED SEPARATELY BY THE OWNER WITH CONCURRENT INSTALLATION DURING THE GENERAL CONTRACTORS WORK. GC - GENERAL CONTRACTOR . ; .7 UN.e ,4, r , ITEM DESCRIPTION AWINVno FURNISHED BY INSTALLED BY REMARKS OWNER GC OWNER GC STOREFRONT • V f7 � — r N co O N r r C r N N CO ' •• ♦ ♦ ••• •..... ♦ ♦ ♦.•• ♦ ♦ ♦ ♦1 • •• ••••• •••••••••••••• • • ' SEE A3.04 ' ' SEE A9.02 AND ELECTRICAL LIGHT FIXTURES DRESSING ROOM MIRRORS IRON HOOKS DOOR ROSETTE CASHWRAP (F -1) FINISHED DECORATIVE METAL ON CASHWRAP SOFFIT DISPLAY GRID BEHIND CASHWRAP (F -2) STANDARD PILASTER (F -3) ENLARGED PILASTER (F 3A) STANDARD PILASTER I MIRROR 1 SHELF (F -38) ENLARGED PILASTER i MIRROR / SHELF (F -3C) PILASTER !MIRROR COMBO (F -3D) 10 FOOT VERT MERCHANDISE STANDARDS (P -1) SIGN VALANCE W/ LIGHT BOX (P -2) SOLID VALANCE (P -2A) VALANCE BRACKET PAIRS (R &L) (P .3) VALANCE CONCEALED STRAPS (P4) - -- - VALANCE END PANEL STRIPS (P -5) VALANCE BAY END CAP PAIRS (R &L) (P-6) SPEAKERS SPECIALTY WALL OVER- PAINTING IN SALES AREA SENSORMATIC MATT & TAG REMOVER GENERAL NOTES A SEE APPROPRIATE DRAWINGS FOR :;E ERAL NOTES OF OTHER DISCIPLINES ELECTRICAL PLUMBING 4WD ME AAN CAL B X NOT SCALE DRAWINGS- LSE DliczNSIONS ONLY C DIMENS+OIkS WHERE S4OWN ARE NORMALLY GIVEN A TO COL LAIN CENTER LINE B TO FINtSI- FACE OF Clot,' OR 3Y16 D. DIMENSIONS SHOWN DN ..ARGER SCALE DRAWINGS GOVERN E FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID NOTIFY ARCHITECT OF UNEXPECTED CONDITIONS OR DISCREPANCIES FROM DRAWINGS F ELEVATIONS AND LEVELS A ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE G. 'ALIGN' AS INDICATED ON THE DRAWING SHALL BE UNDERSTOOD TO MEAN TO AL:GN THE FINISH MKERIAL OF THE WALLS OR COLUMNS INDICATED H ALL INTERIOR GYPSUM WAL... BOARD IS 5/8 ' TYPE X GWB ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE. SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR LOCATION OF WATER RESISTANT GWB I. NOT USED J. PROVIDE WATER RESISTANT TYPE X GWB IN ALL TOILETS. JANITOR'S CLOSETS AND BEHIND INTERIOR BRICK WORK K BEFORE PATCHING ANY FIRE -RATED CMU PARTITION. FILL ANY EXPOSED CELLS SOLID WITH GROUT L. ALL FINISH CEILING HEIGHTS SHALL BE CONFIRMED UNLESS NOTED OTHERWISE ON REFLECTED CEILING PLANS M. PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK. N. PROVIDE AL_ ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION 0. PROVIDE ONE TYPE 5E- 2A -10BC FIRE EXTINGUISHER PER 3.000 SF AND NOT MORE THAN 75 FT OF TRAVEL DISTANCE R THERE SHALL BE NO BACK -TO -BACK ELECTRICAL. TELEPHONE. OR OTHER OUTLETS. SEPARATE OUTLETS BY 6' AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24' MIN. AT FIRE RATED PARTITIONS. Q. WHERE HVAC OR OTHER MECHANICAL ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS. STUDS SHAD BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRAT :ONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE. SMOKE AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. R. ABANDONED UTILITIES SHALL BE REMOVED COMPLETELY TO THEIR SOURCE. SEE ELECTRICAL AND MECHANICAL WALLS. FLOORS. AND CEILING FINISHES SHALL BE PATCHED TO MATCH ADJACENT SURFACES. S. REMOVE ALL EXISTING MERCHANDISING SYSTEMS IJNO. CONFIRM DISPOSAL WITH MALL MANAGEMENT. T. ALL CHANGES IN PROJECT SCOPE DUE TO CONTRACTOR GENERATED ALTERNATIVES OR EXISTING FIELD CONDITIONS SHALL BE TRANSMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. U. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING AND INSTALLING OF OWNER FURNISHED ITEMS LISTED. V. FRCVIDE EXIT ILLUMINATION PER LOCAL CODES W. MODIFY OR REPLACE THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS COMPLY WITH ALL GOVERNING ORDNANCES AND MALL CRITERIA. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS. X. INSTALL ALL COMPONENTS OF FIRE RATED ASSEMBLIES PER RATING CRITERIA. Y. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH MALL CRITERIA AND LOCAL CODES AS REQUIRED. Z. SPRINKLER HEADS MOUNTED IN HARD (GWB) CEILINGS TO BE FULLY RECESSED WITH WHITE CAPS. MALL GENERAL NOTES 1. THE GENERAL CONTRACTOR IS TO READ THROUGH AND FAMILIARIZE THEMSELVES WITH THE MALLS TENANT DESIGN HANDBOOK BEFORE PLACING HIS BID. 2. THE GENERAL CONTRACTOR IS TO SUBMIT A COPY OF THE FOLLOWING ITEMS TO THE LANDLORD BEFORE DOING ANY WORK: A. A QUALIFICATION STATEMENT B. CERTIFICATES OF INSURANCE AS OUTLINED IN THE TENANT CONSTRUCTION MANUAL. (SEE SPECIFICATION MANUAL) C. CONSTRUCTION SCHEDULE. D. LIST OF SUBCONTRACTORS AND CONTACTS. E. COPY OF THE BUILDING PERMIT. F. CURRENT CONTRACTORS LICENSE FOR LOCAL JURISDICTION 3. GENERAL CONTRACTOR MUST HAVE PRE - CONSTRUCTION MEETING WITH THE MALL'S OPERATIONS MANAGER PRIOR TO START OF CONSTRUCTION. 4. A COPY OF THE LANDLORD APPROVED DRAWINGS ARE TO BE ON THE JOB SITE AT ALL TIMES. 5. FOR ADDITIONAL REQUIREMENTS, REFER TO THE CENTERS TENANT DESIGN HANDBOOK ABBREVIATIONS ABBREVIATION TERM ti3V CLG ACT ADJ AFF ALUM ARCH AUTO BLDG BLKG CL CLG CLR CMU COL CONC CONT C DIM DN DS DWG EA EF EL ELCT ENG EQ EQUIP EXS IN F EC FF FIN \Set \AO Ol Cover.dgn 07/31/2003 02: 43 PH ANC AT ABOVE CEILING ACOUSTICAL TILE ADJACENT OR ADJUSTABLE ABOVE FINISHED F! OOR ALUMINUM ARCHITECT. ARCHITECTURAL AUTOMATIC BUILDING BLOCKING CONTROL. JOINT CENTERLINE CEILING CLEAR CONCF.ETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CORRIDOR DRINKING FOUNTAIN DIMENSION DIAMETER DOWN DOCUMENT SET DRAWING EACH EXHAUST FAN EXPANSION JOINT ELEVATION ELECTRICAL ENGINEER EQUAL EQUIPMENT EXISTING EXTERIOR FIRE EXTINGUISER FINISHED FACE FINISH HM HOR HR GT IN INS MAX MECH MANF MIN MISC MO MTD MTL N/A NIC NO NOM NTS DC OD DPNG FURNISHED AND INSTALLED PL/LAM BY OWNER PLMG FLASHING PMR FLOOR PREFAB FOUNDATION PSF FURNISHED BY OWNER PSI INSTALLED BY GENERAL PTD CONTRACTOR PVC FS, FOS FACE OF STUD PWD FT FOOT, FEET R FTG FOOTING RCMU GA GAGE GALV GALVANIZED RD GC GENERAL CONTRACTOR REINF GWB GYPSUM WALLBOARD REQD GYP /SHT GYPSUM SHEATHING SC HW HARDWOOD SD HOLLOW METAL SIM HORIZONTAL HANDRAIL SQ HEIGHT STD INCHES NSULATION STRUC MAXIMUM TPD MECHANICAL TRTNMD MANUFACTURER TS MINIMUM MISCELLANEOUS MASONRY OPENING MOUNTED METAL NON APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OPENING OPPOSITE FIO FLASH FND FOIC EXIT 39 OCCUPANTS MIN EXIT WIDTH REQD: 15.6' EXIT WtDT -I PROVIDED: 36' 1 AREA. 143 SF 1 OCCUPANT MAX SYMBOL LEGEND STORAGE -/ PARTITIONS REVISION BUG KEYNOTE CALL OUT ELEVATION DATUM PARTITION TYPE: SEE A9.01 FOR LEGEND FINISH MATERIAL CALL OUT LIGHT FIXTURE, WINDOW TYPE PLASTIC AMINATE PLUMBING PROTECTED MEMBRANE ROOFING PREFABRICATED POUNDS PER SQUARE INCH PAPER TOWEL DISPENSER POLYVINYL CHLORIDE PLYWOOD RADIUS REINFORCED CONCRETE MASONRY UNIT (CONSTRUCTION) ROOF DRAIN REINFORCED. REINFORCEMENT REQUIRED SOLID CORE SOAP DISPENSER OR SMOKE DETECTOR SQUARE FOOT (FEET) SIMILAR SQUARE STAINLESS STEEL ,STANDARD STEEL STRUCTURE OR STRUCTURAL TOILET PAPER DISPENSER TREATED WOOD (PRESERVATIVE) TUBE STEEL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERTICAL VERTICAL VIF VERIFY IN FIELD (EXISTING CONDITION) VOL VOLUME WI WITH W/O WITHOUT vYD WOOD WP WATERPROOFING, WATERPROOF, WEATHERPROOF EXISTING MASONRY TO REMAIN EXISTING NON -RATED TO REMAIN EXISTING 1 HR. RATED TO REMAIN EXISTING TO BE DEMOLISHED NEW LOW WALL PARTITION NEW NON -RATED PARTITION NEW 1 -HR RATED PARTITION DR. DR. �M. DR. 1 004 j 0•3 I 003 SYMBOLS DOOR NUMBER 001 A 1‹ HARDWARE GROUP i� - INTERIOR ELEVATION NUMBER A4.Q1 ( z ROOM NAME xxxj �- SHEET NUMBER - DETAIL NUMBER SHEET NUMBER - SECTION NUMBER SHEET NUMBER GRID - ROOM NUMBER - (1) HOUR SEPARATION rl E 4 = 0 ELECTRICAL DUPLEX UTILITY OUTLET @ 18' AFF. UNO EXISTING DUPLEX UTILITY OUTLET 4-PLEX OUTLET DEDICATED & ISOLATED UTILITY OUTLET 4D DATA OUTLET 0 JUNCTION BOX SPEAKER 4T TELEPHONE !p WALL SCONCE SPRINKLER 0 SPRINKLER HEAD ADJACENT TIMMY AREA 2,285 SF 77 OCCUPANTS MAX ADJACENT TENANT 0 By Date t - ' Permit No. BUILDING CLASSIFICATION OCCUPANCY: M SEISMIC ZONE: 3 CONSTRUCTION TYPE: 0-N PROJECT AREA: 2,720 SF MAX. OCCUPANTS: APPLICABLE CODES AMERICANS WITH DISABILITIES ACT FILE COPY I understand that the Plan Check approvals are :object to errors and omissions and approval of pans does not author Sze the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. O ( LIFE SAFETY PLAN SCALE: 1l8' = 1'-0' 1 RETAIL. 2,285 SF 130 SF PER OCCUPANT = 77 OCCUPANTS STORAGE: 143 SF / 300 SF PER OCCUPANT =1 OCCUPANT TOTAL = 78 OCCUPANTS TOTAL EXIT WIDTH: 78 OCCUPANTS X .2 INCHES PER OCCUPANT =15.6 INCHES # OF EXITS REQD: 2 WASHINGTON STATE BUILDING CODE, (ADOPTED FROM THE 1997 UNIFORM BUILDING CODE) WITH AMENDMENTS WASHINGTON STATE MECHANICAL CODE, (ADOPTED FROM THE 1997 UNIFORM MECHANICAL CODE) WITH AMENDMENTS WASHINGTON STATE ELECTRICAL CODE, (ADOPTED FROM THE 2002 NATIONAL ELECTRICAL CODE) WITH AMENDMENTS WASHINGTON STATE FIRE CODE, (ADOPTED FROM THE 1997 NATIONAL FIRE CODE) WITH AMENDMENTS WASHINGTON STATE ENERGY CODE, (ADOPED FROM THE 2001 NATIONAL ENERGY CODE) WITH AMENDMENTS WASHINGTON STATE PLUMBING CODE, (ADOPTED FROM THE 2000 UNIFORM PLUMBING CODE) WITH AMENDMENTS SEPARATE PERMIT REQUIRED FOR: r- • :CHANICAL De. ECTRICAL JIBING R AS PIPING CITY OF TUKWILA BUILDING DIVISION REVISIONS "'O O- HAP'fOE'3 SHALL BE MADE TO t "aF (0.4, WIT OUT PROOF w CF TU',WILA BUILDING DIViSIc:, t'TE: REVISIONS WILL REQUIRE A NEW PLAN INAII TTAL At ::) MAY INCLUDE ADDITIONAL PLAN REYE'W F$$ NORDSTROM MALL MAP SCALE: NTS EXIT 39 OCCUPANTS MIN EXIT WIDTH REQ'D• 15.6' EXIT WIDTH PROVIDED: 118' J SEARS THE BON MARCHE INDEX TO DRAWINGS ARCHR'ECTURAL A0.01 GENERAL INFORMATION SHEET A 01 DEYOL'TXOtu DL*N. TEMPORARY 3ARRK ALE A2.01 FLOOR PLAN A3.01 STOREFRCNT PLANS ELEVATION & SECTIONS A3.02 S'OREFFJNT DETAILS Al 03 STOREFRONT ARCH A5.01 ENLARGED TOILET & DETAILS A5 02 NITERIOR DETAILS Al 01 ?EFFECTED CEILING PLAN A8.01 If: FRIOR ELEVATIONS A9.01 PARTmON TYPES A9 02 FINISH. LIGHTING AND DOOR SCHEDULES A10.01 CASHWRAP SECTIONS AND ELEVATIONS A10.02 OWNER FURNISHED FIXTURES AND DETAILS !MECHANICAL & ELECTRICAL IM-1.0 MECHANICAL LEGEND, NOTES. AND PLAN E -1.0 ELECTRICAL NOTES & FIXTURE SCHEDULE E -2.0 LIGHTING PLAN E -3.0 POWER PLAN E-4.0 ELECTRICAL PANEL SCHEDULES. DETAILS (PROJECT TEAM OWNER: ARCH! i ECT. MECHANICAL & ELECTRICAL ENGINEERS: STRUCTURAL ENGINEERS: MALL TENANT COORDINATOR: MALL MANAGEMENT: PROJECT DESCRIPTION PROJECT NAME: PROJECT LOCATION: L_. ZUMIEZ. iNC. 1420 80t. STREET SW. SU'TE A EVEFRETT. WA. 98203 T: (425) 551 -1500 F: (425) 551 -1595 DAVID MIURPH-; t, ALP 2101''! i H AVENUE SUITE 211 SEATTLE, WA 9F 121 T: 206 341 -98'5 F: (206) 341 -9' 17 HARGIS ENGINEERS, ;NC 600 STEWART STREET. SUITE 1800 SEATTLE, WA9810 T: (206 448 -3376 F:1,206) 448 -4450 COFFMAN ENGINEERS '6015TH AVENUE. SUITE 900 SEATTLE WA 98101 T: (206) 623 F: (206) 624 -3775 JOSE HERNANDEZ WESTFIELD SHOPPING CENTERS 11601 WILSHIRE BOULEVARD, 12TH FLOOR LOS ANGELES, CA 90025 P: (310) 575 -5918 F: (575) 575 -5991 HEATHER BLY SOUTHCENTER MALL 633 SOUTHCENTER MALL TUKWILA. WA 98188 P: (206) 246-0423 F (206) 244 -8%7 ZUMIEZ - SOUTHCENTER MALL SOUTHCENTER MALL TUKWILA, WA PROJECT INCLUDES THE INTERIOR DEMOLITION AND RENOVATION OF A 2,720 SF RETAIL SPACE IN SOUTHCENTER MALL, INTO A " ZUMIEZ" RETAIL STORE. PROJECT INCLUDES NEW FINISHES, STORE FIXTURING, CASEWORK, STOREFRONT, LIGHTING. AND MODIFICATIONS TO THE EXISTING MECHANICAL AND ELECTRICAL SYSTEMS. MERVYN'S JC PENNY MD3I7 - ZUMIEZ SPACE # 1008 zummz `. )l THLF- \"TF.R \1 �r.lk # It < a 1 E a• it A 481t3M ?I l E RYH1 `:ARE( I a:r \•rn \nm :m m T a.- ' a .'♦ Mram \un .e. RECEIVED CITY OF TUKWILA AUG1 0 1 2003 PERMIT CENTEP PROIECT NUMBER: 03402 ZUMIEZ STORE # 498 ISSUED FOR PERMIT / BID / MALL REVIEW DATE: 7 - PRELIMINARY MALI REVIEW 7 PERMIT, BID/MALL REVIEW SHEET TITLE: REGnTE X44/ 1 t- /`t�l UOdD AVID J MURPHY STATE OF WASHINGTON GENERAL INFORMATION SHEET SHEET NUMBER' A0.01 11I 1 14x0 SG 200 CFM • 4 ----4 \ II / d t>I FLAG NOTES 1� EXISTING HVAC UNIT TO REMAIN, PROVIDE SERVICE ON COMPRESSOR, FAN MOTORS & VALVES. CLEAN COILS & AIRWAYS & REPLACE FILTERS. UNIT SHALL MEET THE ORIGINAL SPECIFICATIONS. MAINTAIN ACCESSIBILITY TO UNIT. CONTROLS WILL BE THROUGH THE THERMOSTAT. 2 ..> PROVIDE COLLAR AT WALL PENETRATION. VERIFY LOCATION WITH ARCHITECT PRIOR TO INSTALLATION. [3 REMOVE EXISTING EXHAUST FAN & ASSOCIATED DUCTWORK. CAP CURB & SEAL. PROVIDE R-30 INSULATION @ CURB. �4 _ > 32x20 DN TO BULLHEAD TEE W2 -29x18 DUCTS. PROVIDE BLANK SHEET METAL @ TRANSITION TO GIVE APPEARANCE OF CONTINUOUS RUNS. [ i: 9 > PROVIDE NEW THERMOSTAT PER MALL REQUIREMENTS (FIELD VERIFY EXACT LOCATION) SEE MALL TENANT CRITERIA MANUAL FOR CONTROL WIRING & SEQUENCE OF OPERATION. COORDINATE W /LANDLORD. 29x18 FLAT OVAL 5 > NOT USED. > SPIRAL GALVANIZED SHEET METAL WITH SIDE GRILLES. VERIFY MOUNTING HEIGHT OF DUCT W /ARCHITECT PRIOR TO INSTALLATION. PAINT SIDE GRILLES METALLIC SILVER > PROVIDE MODIFICATION OF EXISTING 4" FIRE MAIN BASED ON ARCH RCP. EXISTING MAIN @ 13' -2" BOTTOM OF PIPE. > 24x24 HIGH WALL TRANSFER GRILLES AND DUCT. VERIFY LOCATION WITH ARCHITECT. 10 - REMOVE EXISTING HP -1 & ALL ASSOCIATED DUCTWORK & CONTROLS. CAP CURB & SEAL. PROVIDE R -30 INSULATION ® CURB EXISTING HVAC EQUIPMENT SCHEDULE EXISTING UNITS ARE WATER SOURCE HEAT PUMPS !E)HP -1 TRANE MODEL WCD048C300BC SERIAL #M0810 FOR FUTURE USE 1 T + / 29x18 FLAT OVAL (LHP -2 TRANE WCD120B300BA SERIAL #G3B143789D, 4000 CFM, 208 V/3 Ph, 127,000 BTUH COOLING, 66,900 BTUH HEATING, DESIGN CONDITIONS. IND00P 75` nl_ITDOOR 84 nR/65 ° F WB; SUMMER -50% RH INDOOR INDOOR 70', OUTDOOR 23 DB/19 ° F WB, WINTER 32x20 S.L 29xi8 FLAT OVAL \ 6/ 4=1 GENERAL NOTES SCALE: 1/4"=1'-0" MECHANICAL PLAN DEMOLITION GENERAL NOTES 1. COMPLETELY REMOVE ALL EXISTING SUPPLY, RETURN, AND EXHAUST DUCTWORK FROM THIS SPACE, ALONG WITH ALL THERMOSTATIC CONTROL DEVICES. 1. MODIFY FIRE SPRINKLER SYSTEM TO MATCH ARCHITECTS REFLECTED CEILING PLANS. COMPLY WITH ALL LOCAL, BUILDING AND FIRE CODES. SUBMIT SPRINKLER DRAWINGS TO LANDLORD'S INSURER FOR REVIEW AND APPROVAL. PROVIDE FULLY RECESSED SPRINKLER HEADS WITH TRIM & CAPS WHERE LOCATED IN GWB CEILING & SOFFIT. 2. FIELD VERIFY ALL EXISTING HVAC LOCATIONS PRIOR TO BEGINNING WORK. 3. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES. PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION AND SERVICING OF EQUIPMENT. 4. ALL SUPPLY GRILLES SHALL BE KRUEGER 5880 ALL TRANSFER GRILLES SHALL BE KRUEGER S580. PAINT AS INDICATED, VERIFY W /ARCHITECT. 5. EXISTING SMOKE DETECTION SYSTEMS AND ALL ASSOCIATED DUCTWORK TO REMAIN. 6. START UP AND TESTING OF HVAC EQUIPMENT SHALL BE DONE BY CONTRACTOR. WHEN THE EQUIPMENT IS BEADY FOR START UP, CONTRACTOR SHALL OBTAIN AND COMPLETE THE START UP FORM. 7 AIR BALANCE OF THE HVAC SYSTEM SHALL BE DONE BY DIVISION 15. BALANCE SHALL MEET REQUIREMENTS OF OUTSIDE AIR REQUIREMENT SCHEDULE ON SHEET SUBMIT COPY TO ARCHITECT. 8 SUBMIT ALL MANUFACTURERS INSTALLATION INSTRUCTIONS FOR ALL MECHANICAL APPUANCES TO THE BUILDING DEPT. FOR REVIEW. MOUNT AT 5 - --0' A.F F VERIFY EXACT LOCATION - WA c -4TECT 7 I - • • C SL LL 6 LEGEND 0 _. - ROUND TSTAT THERMOSTAT SUPPLY AIRFLOW RETURN AIRFLOW VOLUME DAMPER REDUCER PIPING UP CW W v �T I SUCTION LINE LIQUID LINE PIPING DOWN COLD WATER WASTE UNDERGROUND VENT FIRE/SMOKE DAMPER FIRE DAMPER CONDENSATE DRAIN 26x14 SG 380 CFM r& - T l rPI 1 29x18 FLAT OVAL F -1 2 > EXH SG SL TG TYP CW HW AFF E ROD c 1 ABBREVIATIONS - SYMBOL DESIGNATES FIXTURE/EQUIPMENT TYPE & NUMBER FLAG NOTE CALLOUT EXHAUST SUPPLY GRILLE SOUND UNED TRANSFER GRILLE TYPICAL COLD WATER HOT WATER ABOVE FINISHED FLOOR EXISTING BOTTOM OF DUCT is 1 zumiez t"OLTHCE LATER MALL SPALF. 1 icc8 '?'u& WII.4. WA 98188 M (: RPHY" `AREY fica !IA 1.1..K11171 T +oc .. .,►_ f foe N Hargis Enginoars, Inc. B00 Stewart St. Ste 1800 Seattle, WA 98101 Tel 206- 448 -3376 Fax: 206- 448 -4450 www.hargis.biz 1EXPIRE _.!ki.100Y RECEIVED OF TUKWILA • 0 1 2003 RMIT CENTER PROJECT NUMBER: 03148 ZUMIEZ STORE 8 498 ISSUED FOR: PERMIT /BID SET DATE: 07.23.03 07.2 8.03 SHEET TITLE: MECHANICAL LEGEND, NOTES, AND PLAN SHEET NUMBER: REVIEW SET PERMIT /BID SET ■ I M•1.0 M