HomeMy WebLinkAboutPermit M03-128 - BRICKLAYERS BENEFICIAL ASSOCIATION• BRICKLAYERS 15208 52 AV S M03 -128 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1157200010 Address: 15208 52 AV S TUKW Suite No: Tenant: Name: BRICKLAYERS BENEFICIAL ASSOCIATION Address: 15208 52 AV S, TUKWILA WA Owner: Name: ST CORPORATION Address: 1200 S 192ND SUITE 300, SEATTLE WA Contact Person: Name: LAIRD DONALDSON Address: 6770 EAST MARGINAL WY S, SEATTLE WA Contractor: Name: OWNER AFFIDAVIT IN FILE Address: 15208 52 AV S, TUKWILA WA Contractor License No: DESCRIPTION OF WORK: HVAC - FAN COILS (6 EACH) WITH HOT WATER HEATING AND SPLIT SYSTEM DX COOLING. ONE (1) BOILER FOR HOT WATER HEATING. ECONOMIZER CYCLE ON MEETING HALL SYSTEM. ** *REVISION #1 - HEATING: HOT WATER HEATING, UNITS HAVE BEEN CHANGED FROM FAN COILS TO GAS FIRED FURNACES. LOCATION OF FAN COILS (FURANCES) HAS CHANGED FROM THE BASEMENT TO THE MAIN FLOOR LEVEL. EXHAUST SYSTEM HAVE REVISED FROM CENTRAL FAN T INDIVIDUAL FANS IN THE VARIOUS RESTROOMS. OUTSIDE AIR INTAKE TO THE UPPER LEVEL FURNACES REVISED TO A ROOF MOUNTED LOUVER. MEETING ROOM IN LOWER LEVEL REVISD FROM HOT WATER HEATING TO A GAS FIRED DUCT FURNACE. * ** Value of Construction: $67,000.00 Type of Fire Protection: SPRINKLERS Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not resume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe orma ce of work. I am authorized to sign and obtain this mechanical permit. Signature: Date: ��� Date: `-/ doc: Mech MECHANICAL PERMIT M03 -128 Permit Number: M03 -128 Issue Date: 12/10/2003 Permit Expires On: 06/07/2004 Expiration Date: Phone: Phone: 206 767 -3986 Phone: Fees Collected: Uniform Mechnical Code Edition: $298.31 1997 Date: - 5 1 7 / 7 - z7 Printed: 04 -19 -2004 .: . W:. i :..a�:..;�in..,.<.::.;;:w:s;,l; Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 (L// /(r'f p— This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M03 -128 Printed: 04 -19 -2004 re 2 1u : 6 .J UO y O , W = CO LL W LL Q: g' O. z 1—. U O O O F-� W W W � — O:. W Z 0 Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1157200010 Address: 15208 52 AV S TUKW Suite No: Tenant: Name: BRICKLAYERS BENEFICIAL ASSOCIATION Address: 15208 52 AV S, TUKWILA WA Owner: Name: ST CORPORATION Address: 1200 S 192ND SUITE 300, SEATTLE WA Contact Person: Name: LAIRD DONALDSON Address: 6770 EAST MARGINAL WY S, SEATTLE WA Contractor: Name: OWNER AFFIDAVIT IN FILE Address: 15208 52 AV S, TUKWILA WA Contractor License No: DESCRIPTION OF WORK: HVAC - FAN COILS (6 EACH) WITH HOT WATER HEATING AND SPLIT SYSTEM DX COOLING. ONE (1) BOILER FOR HOT WATER HEATING. ECONOMIZER CYCLE ON MEETING HALL SYSTEM. Value of Construction: $67,000.00 Type of Fire Protection: SPRINKLERS Permit Center Authorized Signature: doc: Mech Print Name: R a i MECHANICAL PERMIT I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfformap work. I am authorized to sign and obtain this mechanical permit. Signature: W This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M03 -128 Permit Number: M03 -128 Issue Date: 12/10/2003 Permit Expires On: 06/07/2004 Expiration Date: Fees Collected: Uniform Mechnical Code Edition: Phone: Phone: 206 767 -3986 Phone: $293.38 1997 Date: Date: /. ` fb -63 Printed: 12 -10 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 1157200010 Permit Number: M03-128 Address: 15208 52 AV S TUKW Status: ISSUED Suite No: Applied Date: 08/12/2003 Tenant: BRICKLAYERS BENEFICIAL ASSOCIATION Issue Date: 12/10/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or Tess, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 11: Fuel burning appliances may not be installed in sleeping rooms, U.M.C. 304.5. 12: Appliances which generate flame, spark or glowing ignition, shall be elevated 18 inches above the floor (U.M.C. 303.1.3.). 13: Water heater shall be anchored to resist earthquake (U.P.C. 510.5). 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 16: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) doc: Conditions M03 -128 Printed: 04 -19 -2004 ..,.,-<.�..,... �... -..... 17: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 18: Local U.L. central station supervision is required. (City Ordinance #1900) 19: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 20: Duct detectors shall send a supervisory signal only upon activation. 21: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 22: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 23: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. L Signature: i ,� -� l Date: n Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 M03 -128 Printed: 04 -19 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1157200010 Permit Number: M03 -128 Address: 15208 52 AV S TUKW Status: ISSUED Suite No: Applied Date: 08/12/2003 Tenant: BRICKLAYERS BENEFICIAL ASSOCIATION Issue Date: 12/10/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 11: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Conditions PERMIT CONDITIONS 12: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) M03 -128 Printed: 12 -10 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 15: Local U.L. central station supervision is required. (City Ordinance #1900) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 17: Duct detectors shall send a supervisory signal only upon activation. 18: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 19: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 20: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions d--.R5 uu ) RJ? \SI \oc .h- M03 -128 Date: [ 2 ' 1 d - c 3 Printed: 12 -10 -2003 Name: Mailing Address: E -Mail Address: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: \applications\permit application (3.2003) 3/2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: 1 0 r Tenant Name: °vt¢ Ca (,t.VA `eA Property Owners Name: may ( ci et/� 7'e,t`e Mailing Address: te 0 Company Name: / n� Mailing Address: -e'- A - )1) -P f 1-e LA) cVO Vl i� ,'i�0 r t /!—'r j t� y> Page 1 King Co Assessor's Tax No.: L t C, /747-00 (� - D 7 ) �t 'r irt Suite Number: City New Tenant: D .... Yes p ..No State �[Tc 1 V'c. Dol,ta ' d x Day Telephone: %(.o l.� - 4 '"- 0 1A j +71 i In ��,�" CG1 City -ea - H l �F (A) A- �j i o State Zip Fax Number: '()(p � - 7(0/7 - �j T -27 C,1G�,cr. i,/ - 61/1'e (k r ( City Day Telephone: Fax Number: City Day Telephone: Fax Number: Zip 2(9 (r t 9 S - 3 State Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD: =-`All plans must be wet stamped byArchitectrofRecord: State Floor: I A 10c7 Zip Zip ENGINEER OF RECORD := ;All.plans must btz.wet stamped by,.Engineer oi'Record Company Name: g) 1 D >✓'G' t✓ ` 7 l�E' . r Y�l/ ("?'lam ' Mailing Address: lex 1'.1 i t �' 'et/ -�►� L) l L ?-r 4 �fCt. (4( u) A- GtcS(C� City State Zip Day Telephone: '206: ' C-; '2- ((0( Fax Number: 'L0(n [PP11411"?.P.MWT.PIV9givIATIQT, -206 431 -367 ark.. •� ' %. f Valuation of Project (t:ontraptor'R aid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? 0 ..Yes ❑.. No If "yes ", see Handout No. for requirements. .Provide All Building Areas in Square Footage Below 1 "'Floor .. 2 "° Floor 3 Floor ' Floors`_ Basement:: Accessory Structure!: Attached Garage Detached Garage Attached Carport Detached Carport;- •Covered Deck Uncovered Deck Interior: , Remodel Addition'to ..Existing Structure Type of .Construction per UBC .. Type of Occupancy per UBC PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: tappliations4xrmit application (3.2003) 3/2003 Page 2 Handicap: Will there be a change in use? 0 ....Yes 0 ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers 0..Automatic Fire Alarm 0..None 0.Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No If"yes". attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. Z H W _ 00 CO O W U W WO u . = W 2I— I- O Z I— �p uj N O 1— W 1— u" O w 1622 H t- O Z :PUBLIC WORKS PERMIT INFORMATION: . 206 -433; 0179 Scope of Work (please provide detailed information): Please refer to. Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila 0... Water District # 125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑...Temporary Water Meter Size.. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public Upplicatiorulpermit application (3.2003) 3/2003 fl 11 ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 11 Call before you Dig: 1- 800 - 424 -5555 WO# WO# W O# Private Private FINANCE INFORMATION Fire Line Size at Property Line ❑...Water ... Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip ❑ .. Highline ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑ ... Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage Page 3 ❑ ...Renton ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size " Unit Type: _ . Qty _Unit Type: Qty : Unit Type: YP .. Qty Boiler/Compressor: oer om P Qty Y Fumace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Fumace >100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU i Floor Furnace Ventilation Fan Z 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent ( Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic t7 j(., <-Utc-Q v‘e (:•v)tic, - Air Handling Unit <= I0,000 CFM (-P Incinerator - Comm/Ind 'MECHAN c p.wwry,w(34MATION _ 206 =43,1 -3 670 \applications\permit application (7.7003) Indicate type of mechanical work being installed and the quantity below: BUILDING OWNER OR AUTHORIZED AGENT: Signature: '-- 7/ Print Name: IAA.(/ V " /�'j/ �t' t' � - IV'CLU 'FOV Day Telephone: Mailing Address: ! 27 -1 T7 rJt,tC-,l:l . zl%Ll � E' City PAM. 4 MECHANICAL CONTRACTOR INFORMATION Company Name: �� .�� � ic- wILt6,'1' Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ L2 000C I Scope of Work (please provide detailed information): l�'>/ L . F<"r IA cc); `� (( ` rt1 wt - ' 'A Vt t L'c\ t4YGt VtCI GLU } � i �ll -PtitA 1�}� C ��C�� i \/ t "�? Lit/ *o v � C O vaowt t 7,ev cc l \r- wk •e tiw- a L Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ... Replacement .... ❑ Fuel Type: Electric ❑ Gas... Other: 'PERMIT APPLICATION NOTES - .Applicable tti;all permits in t60application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: A • J Z -0 '27 7:4 2 7L0 7 (A_J .4- State Zip I Date Application Accepted: go--/z-e3 Date Application Expires: Staff Init . 1 \k i�:::N4 .!4 4tit `.:'Gf :;g{i �� 4ntl. ?L:lT2. k�: « J..����E�•. TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Z RECEIPT re Parcel No.: 1157200010 Permit Number: M03 -128 o Address: 15208 52 AV S TUKW Status: ISSUED to 0 Suite No: Applied Date: 08/12/2003 W Applicant: BRICKLAYERS BENEFICIAL ASSOCIATION Issue Date: 12/10/2003 N LL wO 2 Receipt No.: R04 -00450 Payment Amount: 4.93 4 N 3 Initials: SKS Payment Date: 04/19/2004 10:55 AM H w User ID: 1165 Balance: $0.00 ? I._ I-- C) zi— t)) W Payee: BRCKLAYERS BENEFICIAL ASSOCIATION 0 N 0 1— w 1- U Type Method Description Amount W ~O Z: Payment Check 2171 4.93 W • c O F O Account Code Current Pmts MECHANICAL - NONRES 000/322.100 13.85 PLAN CHECK - NONRES 000/345.830 -8.92 Total: 4.93 0070 04/20 9716 -T0TAL - 4.93 Printed: 04 -19 -2004 z Initials: SKS 1 User ID: 1165 Receipt No.: R03 -01464 doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1157200010 Permit Number: M03428 Address: 15208 52 AV S TUKW Status: APPROVED Suite No: Applied Date: 08/12/2003 Applicant: BRICKLAYERS BENEFICIAL ASSOCIATION Issue Date: Payee: BRICKLAYERS BENEFICIAL ASSOCIATION TRANSACTION LIST: Type Method Description Amount Payment Check 2113 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000/322.100 234.70 000/345.830 58.68 Payment Amount: 293.38 Payment Date: 12/10/2003 02:38 PM Balance: $0.00 293.38 Total: 293.38 5476 12/10 9710 TOTAL 293.38 Printed: 12 -10 -2003 Tp f Is or 0 A des Cle: n 5 Seil Isrcin: Dt atd euse 3 (- ) v.i, Poe N: + / .0 - 2 37 7 8 (fl03 '"lag INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ;,c4Lj N pproved per applicable codes. Corrections required prior to approval. COMMENTS: fJk To Gh „C� Inspector: LJ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: Pr ec Type of Inspection: Address: f S 0'8 $2 41 ate Cal / U � . leds.--- Special Instructions: Date Wanted: 11-- ° — O S a.m. p.m. Requester // Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 MO 3 -i2 %Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: spector• Date: L 0 REINSPECTION FEE RE • UIRED. Pri • to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. R ipt No.: {Date: Projg t: Dt■Cv. CA.`I Type of Inspection: P` =, Address: I 20 8 52 Av.- S Date Called: �z� _-- o f rl a . Special instructions: Date Wanted: ' d 1 2-/0 a.m. 15, Requester: - 3 1 1 Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 v1103 -!Z8 COMMENTS: 1 " n ,t- ,-t /'d c c4 ,L. ,e — c9ti-.n e", Ins ec •r: Date: i n _ <^. ` L Ill- 0 f p 7.00 REINSPECTION FEE EQUIRED. Prio to inspec ion, fe must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Ty of Insn: 1 J Address: 15' 5' ; ,4 I.) . Secu( -e. Cti c.Cp() -) c a, �� e c1r (.1) A SC V P (A) % A L v r) :1(i \ 21 Ones (� , Qt' f C� ( PC'\ noo rtrLf t (' 1 •D 5 1 Pro' ct: Ty of Insn: 1 J Address: 15' 5' ; ,4 S Date Called. 03 )ac, /0S' Special Instructions: Date Wanted: , 0j p". Requester ) Phone No: /90e - 7t4-c5V 'INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431 =3670 Approved per applicable codes. 121 Corrections required prior to approval. Inspector: I Date: ' 0 - 10 3 ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: 'Date: U 2 6 U O 0 N J = W u W U. I d = W H = Z I- I- CD W I- uj 0 W I - U I- — O .. N O I-- z Pr t: Type of Ins a tion: Add J Date Called: 1r 1 plA Spe ial I nstructions: Instructions: Date Wanted: D ` , C ` C i p.m. Requester: / I � 1 1 1 PhNo: °4) — 7Rto- -- 75tR I INSPECTION RECORD Retain a copy with permit INSPECYON . NO. CITY OeTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER (206)431 -3670 r)k „. ... p proved per applicable codes. 0 Corrections required prior to approval. COMMENTS: pcu �ir C • l tea” .4- p fh �n e /� Date: /. // 4, y� ewe t___ 0 REINSPECTION FEE EQUIRED. P for to inspection, fee must be at 6300 Southcenter Blv' , Suite 10 Call to schedule reinspection. Receipt No.: Date: k Project' Type of Inspection: • Addr s `� /5 " YA Date ailed: Special Instructions: Date Wanted: / 0-1 C- J� e-( egt Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit M PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: / 04 . /62, 7 ,)-7(.‘„,1, 77-1 c'‘obt, ,‹ eh" I Date: Jo/ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee mus be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. Project: r ,'e k vi ✓ Type of Inspection: 2v h - r NI S,viStl j,, li Address: 1 1-S2(9e 52. ftvi so Date Called: In— i c_9`-/ Special Instructions: Date Wanted: 10 -- ) 3 —PL) a.m. p.m. Requester: i 1 Phpne No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit W1n -tzs (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: P spec r. 'Date: I , 3 — ok- L 47.05YREINSPECTION FEE RE�UIRED. Ptior to inspection, fee must be r idd t 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. • Recelp - f No.: Date: COMMENTS: .. 1 li el (4 Ilr`IS MA; e. "NO( he NL $ i v „L4-e Date Called �/ ^- 9 s\--\oir A rkocA\ `i AA , )0(..-e. vielat. - l /k- -1-n i N SA it of 7`C' Requesters AJ O*P ".. (..-\Z k j 4' ,c-r-VtOk^ (1 rct t ov\ • O V N C1 ✓' pi-t- () L • i P `t- ?c1 ()uUef O ---\-ra(J -6' vv- tvsov-C-.- • Pr ct: , q Typee�f Inspect / /' Address: / 20 G 5O � a LZP S, Date Called �/ ^- 9 Special Instructions: - / Date Wanted: a.m. Requesters Phone No: (JO & ) 77& X57 INSPECTION NO. CITY. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 A pproved per applicable codes. Inspector: \7 _ /j Q C Date: Q— 01 -0yl 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit PER J (206)431 -3670 El Corrections required prior to approval. 7 =77, gi:373.5) — s - ' Project Name 3 r c / r i Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor.: Pre-Fire: Permits: P Authorized Signature FINALAPP.FRM Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM . .A Retain .current inspection schedule , Ai '.,.., i Needs shift inspection \.' . Approved without correction notice Approved with correction notice issued Rev. 2/19/98 Steven M. Mullet, Mayor Permit No. / Address /J o :‘,:t Ai S Suite # Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575:4439 �A SIDER + BYERS 192 Nickerson, Suite 300 Seattle, WA 98109 *el: 206 -285 -2966 ax: 206 -285 -1045 f=IRM: Newton and Associates ATTN: Margaret Newton F ROM: Drew Arp I ROJECT:NAME /NO.: Bricklayer Meeting Hall 14 Summary of Mechanical Revisions to Plans que to high construction costs the original mechanical design has been revised. The following outlines the revisions: Pilease note: 3. Fax:2062851045 CI APPROVEOIIA A PP 1 6 2N4 OOLONG G 0 N FAX COVER SHEET I ufldersf d fh Apr 8 2004 8:20 DATE: 4 -7 -04 1. The cooling (DX split systems) has not changed. 2. The equipment zoning has not changed. 3. The equipment sizing (CFM) has not changed. 4. The number of units has not changed 5. HVAC controls remain the same, programmable t- stats. REVISION N0. P. 01 SIDER . BYERS FAX. NO.: W (a - 2. + 2 -. 4 S �3 RECEIVED CITY OF Tl1KWII A APR 0 8 2004 PERMIT CENTER visions: 1. Heating: the original boiler /hot water heating system has been deleted. in place of hot water heating, the units have been changed from fan coils to gas fired furnaces. 2. The Original mechanical layout had the fan coils that serve the upper level located in the basement. To reduce the amount of ductwork, the location of the fan coils (furnaces) has changed from the basement to the main floor level. The furnace are now enclosed in a furnace closet. The lexhaust systems have been revised from a central fan to individual fans in the \arious restrooms. SIDER 4 BYERS Fax:2062851045 Anr 8 2004 8:20 P.02 4. The outside air intake to the upper level furnaces has been revised from the basement mechanical room louver intake to a roof mounted louver in a dormer style roof detail. 5. The meeting room in the lower level has been revised from hot water heating to a gas :fired duct furnace. But other wise remains the same with economizer function. If there are any questions, please call our office. dopy: Bricklayer's Hall RECEIVED CITY OF TlI JKWII A APR 0 8 2004 PERMIT CENTER Protect Name: Bricklayers 41 Prepared by: Sider & B ers Hourly Analysis Program v.4.1 A jstem Sizing Summary for Block )ad Air System Information Air System Name Block Load Number of zones 1 Equipment Class UNDEF Floor Area 10410.0 ft Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space Toads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 26.4 Tons Load occurs at Jul 1600 Total coil load 316.4 MBH OA DB / WB 84.5 / 64.8 °F Sensible coil load 316.1 MBH Entering DB / WB 80.1 / 64.6 °F Coil CFM at Jul 1600 13693 CFM Leaving DB / WB 68.2 / 66.8 °F Max block CFM at Jul 1600 13693 CFM Coil ADP 56.8 °F Sum of peak zone CFM 13693 CFM Bypass Factor 0.100 Sensible heat ratio 0.999 Resulting RH 50 % ft 394.9 Design supply temp. 56.0 °F BTU /(hr -ft 30.4 Zone T -stat Check 1 of 1 OK Water flow @ 10.0 °F rise 63.31 gpm Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 382.8 MBH Load occurs at Des Htg Coil CFM at Des Htg 13693 CFM BTU /(hr -ft 36.8 Max coil CFM 13693 CFM Ent. DB / Lvg DB 51.4177.9 °F Water flow @ 20.0 °F drop 38.31 gpm Supply Fan Sizing Data Actual max CFM at Jul 1600 13693 CFM Fan motor BHP 0.00 BHP Standard CFM 13374 CFM Fan motor kW 0.00 kW Actual max CFM/ft 1.31 CFM /ft Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 5320 CFM CFM /person 20.00 CFM/person CFM /ft 0.51 CFM /ft FILE COPY RECEIVED cwr' OF TUKWILA AUG 1 2 2003 PERMIT CENTER 04/28/2003 02:49PM MD3•128 Page 1 of 1 Zone Name / Space Name ': ; Mutt. C oling 0 Sensible (MBH) ' .; Time of .: ' Load ' :Air Flow (CFM) ; > Heating . Load (MBH) :. .'Floor ` Area (ft ° Space ; CFM /ft' Zone 1 Zone Floor Area (ft') . . Zone . CFM /ft' Zone 1 288.9 13593 104 LOBBY 1 27.4 Jul 1600 1288 15.2 680.0 1.89 105 MEETING 1 87.8 Jul 1600 4130 24.9 2760.0 1.50 106 KITCHEN 1 9.4 Jul 1600 444 3.3 180.0 2.47 101 MECHANICAL 1 9.6 Jul 1600 453 2.4 144.0 3.15 102 WOMEN 2 1.2 Jul 1600 57 1.3 192.0 0.30 107 HALL 1 1.0 Jul 1600 47 1.0 195.0 0.24 108 MACHINE 1 6.2 Jul 1600 293 3.8 222.0 1.32 201 LOBBY 1 14.7 Jul 1600 693 7.3 481.0 1.44 202 CONF 1 11.9 Jul 1600 560 5.9 315.0 1.78 213 DILBERTVILLE 1 13.0 Jul 1600 609 1.6 725.0 0.84 204 OFFICE 1 7.8 Jul 1600 365 5.2 252.0 1.45 205 OFFICE 1 4.1 Jul 1600 195 2.3 169.0 1.16 206 OFFICE 1 4.1 Jul 1600 195 2.3 169.0 1.16 207 STAFF 1 6.7 Jul 1600 317 2.7 195.0 1.62 209 CORRIDOR 1 2.2 Jul 1600 105 2.0 303.0 0.35 211 WOMEN 2 1.6 Jul 1600 76 0.6 273.0 0.28 250.A OFFICE 1 26.1 Jul 1600 1229 14.5 1120.0 1.10 250.B OFFICE 1 32.9 Jul 1600 1549 15.4 1120.0 1.38 240 ELEVATOR 1 6.9 Jul 1600 325 0.1 60.0 5.42 241 STAIR 1 5.5 Jul 1600 259 4.4 156.0 1.66 212 CLOSET 1 0.3 Jul 1600 13 0.1 52.0 0.24 203 OFFICE 1 5.4 Jul 1600 255 2.3 182.0 1.40 Zone Name ::. Maximum Cooling Sensible (MBH) Design Air Flow (CFM) : ' Minimum Air Flow (CFM) Time of Peak Load :. Maximum : Heating Load (MBH) '' Zone Floor Area (ft') . . Zone . CFM /ft' Zone 1 288.9 13593 13593 Jul 1600 120.5 10410.0 1.31 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Coincident space loads Zone Sizing Data Zone Terminal Sizing Data Space Loads and Airflows Hourly Analysis Program v.4.1 'ne Sizing Summary for Block Lc Calculation Months Jan to Dec Sizing Data Calculated 04/28/2003 02:49PM No Zone Terminal Sizing Data required for this system. Page 1 of 1 Air Sy :m Design Load Summary for BI .c Load Project Name: Bricklayers 41 Prepared by: Sider & Byers Hourly Analysis Program v.4.1 04/28/2003 02:49PM Page 1 of 1 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB / WB 84.5 OF / 64.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS . Details Sensible (BTU /hr) Latent (BTU /hr) Details Sensible (BTU/hr) - Latent (BTUIhr) - Window & Skylight Solar Loads 2287 ft 98806 - 2287 ft Wall Transmission 4746 ft 10914 - 4746 ft 31325 - Roof Transmission 7010 ft 17200 - 7010 ft 15248 - Window Transmission 2287 ft 9004 - 2287 ft 64479 - Skylight Transmission 0 ft 0 - 0 ft 0 - Door Loads 95 ft 3038 - 95 ft 2876 - Floor Transmission 6865 ft 0 - 6865 ft 6542 - Partitlons 0 ft 0 - 0 ft 0 - Ceiling 0 ft 0 - 0 ft 0 - Overhead Lighting 11534 W 36488 - 0 0 - Task Lighting 1286 W 4209 - 0 0 - Electric Equipment 14634 W 48309 - 0 0 - People 266 55910 33695 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 5000 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 Total Zone: Loads . ::. 288876 33695 120471 0 Zone Conditioning - 275796 33695 - 119356 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 13593 CFM 0 - 13593 CFM 0 - Ventilatlon Load 5320 CFM 40259 -33380 5320 CFM 263487 0 Supply Fan Load 13593 CFM 0 - 13593 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads :` 316064 ;.. 315 ::> 382843 Central Cooling Coil - 316054 318 - 0 0 Central Heating Coll - 0 - - 382843 - Total Conditioning . .::: 316064 :. 318 382843 0 Key Positive. values are clg:loads: Negative values are htg loads Positive values are htg loads Negative. values are clg loads Air Sy :m Design Load Summary for BI .c Load Project Name: Bricklayers 41 Prepared by: Sider & Byers Hourly Analysis Program v.4.1 04/28/2003 02:49PM Page 1 of 1 Project Name: Bricklayers 41 Prepared by: Sider & Byers Air SystE Sizing Summary for Banquet Me ' ng Room Air System Information Air System Name Banquet Meeting Room Number of zones 1 Equipment Class CW AHU Floor Area 2760.0 ft Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Calculation Months Jan to Dec Space CFM Coincident space Toads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil Toad 9.4 Tons Load occurs at Aug 1400 Total coil load 112.7 MBH OA DB / WB 84.6 / 64.8 °F Sensible coil Toad 112.7 MBH Entering DB / WB 82.2 / 64.9 °F Coil CFM at Aug 1400 4342 CFM Leaving DB / WB 57.8 / 56.1 °F Max block CFM at Sep 1400 4342 CFM Coil ADP 55.1 °F Sum of peak zone CFM 4342 CFM Bypass Factor 0.100 Sensible heat ratio 1.000 Resulting RH 52 % ft 294.0 Design supply temp. 56.0 °F BTU /(hr -ft 40.8 Zone T -stat Check 1 of 1 OK Water flow @ 10.0 °F rise 22.54 gpm Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 174.1 MBH Load occurs at Des Htg Coil CFM at Des Htg 4342 CFM BTU /(hr -ft 63.1 Max coil CFM 4342 CFM Ent. DB / Lvg DB 37.4175.2 °F Water flow @ 20.0 °F drop 17.42 gpm Supply Fan Sizing Data Actual max CFM at Sep 1400 4342 CFM Fan motor BHP 0.00 BHP Standard CFM 4272 CFM Fan motor kW 0.00 kW Actual max CFM /ft 1.57 CFM /ft Fan static 0.00 in wg 04/28/2003 02:49PM Outdoor Ventilation Air Data Design airflow CFM 3000 CFM CFM /person 15.00 CFM /person CFM/ft 1.09 CFM /ft Hourly Analysis Program v.4.1 Page 1 of 1 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow ::,. .(CFM) : Minimum Air : Flow (CFM) Time of Peak Load ::: Maximum :Heating Load (MBH) Zone . Floor : _, _ :Area (ft=) Zone CFM/ft* Zone 1 92.3 4342 4342 Sep 1400 24.9 2760.0 1.57 Zone Name ! : : Space:Name >: Mult: C oolmg S ensible ;fMBH) Time o f >;; ': Air Flow.: ;;CFM) : Heating . Load ;;.(M8H) Floor Area ;(ft') Space ` s CFMlft? Zone 1 105 MEETING 1 92.3 Sep 1400 4342 24.9 2760.0 1.57 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space Toads Zone Sizing Data Zone ;ing Summary for Banquet Meeti 'Room Calculation Months Jan to Dec Sizing Data Calculated 04/28/2003 02:49PM Zone Terminal Sizing Data Space Loads and Airflows Hourly Analysis Program v.4.1 No Zone Terminal Sizing Data required for this system. Page 1 of 1 Air System , 3ign Load Summary for Banquet eating Room Project Name: Bricklayers 41 Prepared by: Sider & Byers ZONE LOADS Window & Skylight Solar Loads Wall Transmission Roof Transmission Window Transmission Skylight Transmission Door Loads Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor >? TotaliZone.Loads?::::;: Zone Conditioning Plenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coil Fans Duct Heat Gain / Loss ». Total System Loads::' ;:.:. Central Cooling Coil Central Heating Coil >'<Total Conditioning • Key DESIGN COOLING COOLING DATA AT Aug 1400 COOLING OADB /WB 84.5 °F /648 °F Details 560 ft 723 ft 1032 ft 560 ft 0 ft 0 ft 2760 ft 0 ft 0 ft 2981 W 0W 2760 W 200 0%/ 0% 0% 0% 0% 4342 CFM 3000 CFM 4342 CFM 0% Sensible (BTU /hr) 25765 1812 2826 2060 0 0 0 0 9322 0 9067 41206 0 0 0 92057 89905 0 0 0 0 22750 0 0 0 112865 112655 0 .112655 Latent (BTUIhr) 24000 0 0 24000 24000 -24000 0 Positive ;values are clgIoads Negative. values are htg loads DESIGN HEATING HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F Details 560 ft 723 ft 1032 ft 560 ft 0 ft 0 ft 2760 ft 0 ft 0 ft 0 0 0 0 0% 0 0 0 4342 CFM 3000 CFM 4342 CFM 0% Sensible (BTUIhr) 4772 2245 15792 0 0 2080 0 0 0 0 0 0 0 0 0 24889 25169 0 0 0 0 148896 0 0 0 :174066 0 174065 • .. ` , .174065 Latent (BTU /hr) 0 0 0 0 0 0 0 Positive values are htg loads Negative values are clg loads Hourly Analysis Program v.4.1 04/28/2003 02:49PM - .�•:.•. ?.:. ; Page 1 of 1 Project Name: Bricklayers 41 Prepared by: Sider & Byers Air System Information Air System Name AHU-2 System Sizing Summary for AH Number of zones 1 Equipment Class CW AHU Floor Area 567.0 ft Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 1.1 Tons Load occurs at Jul 1500 Total coil load 12.7 MBH OA DB / WB 85.0 / 65.0 °F Sensible coil load 11.8 MBH Entering DB / WB 78.1 / 64.4 °F Coil CFM at Jul 1500 549 CFM Leaving DB / WB 57.9 / 56.6 °F Max block CFM at Jul 1600 549 CFM Coll ADP 55.7 °F Sum of peak zone CFM 549 CFM Bypass Factor 0.100 Sensible heat ratio 0.925 Resulting RH 50 % ft 535.5 Design supply temp. 56.0 °F BTU/(hr-ft 22.4 Zone T-stat Check 1 011 OK Water flow @ 10.0 °F rise 2.54 gpm Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 8.4 MBH Load occurs at Des Htg Coil CFM at Des Htg 549 CFM BTU/(hr-ft 14.8 Max coil CFM 549 CFM Ent. DB / Lvg DB 64.3 178.7 °F Water flow @ 20.0 °F drop 0.84 gpm Supply Fan Sizing Data Actual max CFM at Jul 1600 549 CFM Fan motor BHP 0.00 BHP Standard CFM 640 CFM Fan motor kW 0.00 kW Actual max CFM/ft 0.97 CFM/ft Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 60 CFM CFM/person 15.00 CFM/person CFM/ft 0.11 CFM/ft Hourly Analysis Program v.4.1 04/28/2003 02:49PM Page 1 of 1 Zone Name:.. .. Maximum Cooling Sensible - (MBH) ': Design Air Flow (CFM) Minimum Air Flaw :::(CFM) :. : . Time of Peak . Load Maximum Heating Load (MBH) :: Zone Floor Area (it=) Zone CFMlfta Zone 1 11.7 549 549 Jul 1600 5.6 567.0 0.97 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space loads Zone Sizing Data Zone Sizing Summary for AHU -: Calculation Months Jan to Dec Sizing Data Calculated 04/28/2003 02:49PM Zone Terminal Sizing Data Space Loads and Airflows Zone 1 102 WOMEN 106 KITCHEN 107 HALL 1 1 1 ;;Cooling Sen3ibie jMBH► 1.2 9.4 1.0 Jul 1600 Jul 1600 Jul 1600 57 444 47 eating Load (MBH) 1.3 3.3 1.0 192.0 180.0 195.0 . Space CFM /tt° 0.30 2.47 0.24 Hourly Analysis Program v.4.1 No Zone Terminal Sizing Data required for this system. Page 1 of 1 Project Name: Bricklayers 41 Prepared by: Sider & Byers Hourly Analysis Program v.4.1 Air stem Design Load Summary for 1U -2 ZONE LOADS Window & Skylight Solar Loads Wall Transmission Roof Transmission Window Transmission Skylight Transmission Door Loads Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor »;Total Zone. Loads :'.> ' :; :: Zone Conditioning Plenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coil Fans Duct Heat Gain / Loss iTotatSystem LaadS Central Cooling Coil Central Heating Coil Total :Conditioning Ke y; DESIGN COOLING COOLING DATA AT Ju11600 COOLING OA DB ! WB 85.0 °F / 66.0 °F Details 16 ft 469 ft 120 ft 16 ft 0 ft 42 ft 567 ft 0 ft 0 ft 568 W 186 W 2000 W 4 0 % /0% 0% 0% 0% 549 CFM 60 CFM 549 CFM 0% Sensible (i3TU /hr) 260 853 341 65 0 169 0 0 0 1786 607 6587 975 0 0 0 • 11642 11262 0 0 0 0 495 0 0 0 ';:11757 11757 0 11757 Latent (BTU /hr) 1320 0 0 0 1320 1320 -371 949 950 960 Posib ve`.values are clgioads Negative values ..are htg loads DESIGN HEATING HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F Details 16 ft 469 ft 120 ft 16 ft 0 ft 42 ft 567 ft 0 ft 0 ft 0 0 0 0 0% 0 0 0 549 CFM 60 CFM 549 CFM 0% Sensible (BTU/hr) 3096 261 451 0 1184 571 0 0 0 0 0 0 0 0 0 5563 5421 0 0 0 0 2956 0 0 0 8377 0 8377 8377 Latent (BTUIhr) 0 0 0 0 0 0 0 Positive :are ;htg loads' • Negative values are clg loads 04/28/2003 02:49PM Page 1 of 1 Z 1 z ~ W re ,.j0 0 0 C1 J Nu_ WO u D. = W Z � I— O W uj O N 0 I— W uJ O t— Z Project Name: Bricklayers 41 Prepared by: Sider & Byers System Sizing Summary for AH Air System Information Air System Name AHU-3 Number of zones 1 Equipment Class CW AHU Floor Area 836.0 ft Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil Toad 1.6 Tons Load occurs at Jul 1400 Total coil load 18.7 MBH OA DB / WB 84.6 / 64.8 °F Sensible coil load 18.4 MBH Entering DB / WB 78.2 / 64.3 °F Coil CFM at Jul 1400 879 CFM Leaving DB / WB 58.4 / 57.1 °F Max block CFM at Jun 1000 879 CFM Coil ADP 56.2 °F Sum of peak zone CFM 879 CFM Bypass Factor 0.100 Sensible heat ratio 0.985 Resulting RH 50 % ft 636.3 Design supply temp. 55.0 °F BTU /(hr -ft 22.4 Zone T -stat Check 1 of 1 OK Water flow @ 10.0 °F rise 3.74 gpm Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 14.8 MBH Load occurs at Des Htg Coil CFM at Des Htg 879 CFM BTU /(hr -ft 17.7 Max coil CFM 879 CFM Ent. DB / Lvg DB 62.9 / 78.7 °F Water flow @ 20.0 °F drop 1.48 gpm Supply Fan Sizing Data Actual max CFM at Jun 1000 879 CFM Fan motor BHP 0.00 BHP Standard CFM 866 CFM Fan motor kW 0.00 kW Actual max CFM /ft 1.06 CFM/ft Fan static 0.00 in wg 04/28/2003 02:49PM Outdoor Ventilation Air Data Design airflow CFM 120 CFM CFM /person 15.00 CFM /person CFM/ft 0.14 CFM/ft Hourly Analysis Program v.4.1 Page 1 of 1 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Coincident space loads Zone Sizing Data Zone Terminal Sizing Data Space Loads and Airflows Hourly Analysis Program v.4.1 Zone Sizing Summary for AHU Calculation Months Jan to Dec Sizing Data Calculated No Zone Terminal Sizing Data required for this system. Zone 1 205 OFFICE 206 OFFICE 207 STAFF 209 CORRIDOR 1 1 1 1 Cooling Sensible •(MBH) 4.7 4.7 7.4 2.0 Time Load Jun 1000 Jun 1000 Jun 1000 Jun 1000 Flow (CFM► 220 220 347 92 Heating Load (MBH) 2.3 2.3 2.7 2.0 Floor Area ( g = : 169.0 169.0 195.0 303.0 1.30 1.30 1.78 0.30 04/28/2003 02:49PM Page 1 of 1 • : Maximum Design Minimum Time ;: Maximum : Zone :. Cooling Air Air of Heating :' Floor Sensible Flow Flow Peak Load :: Area . Zone Zone Name ;(MBH) .`: :.(CFM) ... ; Load • (MOH) : °; (ft') ; CFM/ft Zone 1 18.7 879 879 Jun 1000 9.3 836.0 1.05 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Coincident space loads Zone Sizing Data Zone Terminal Sizing Data Space Loads and Airflows Hourly Analysis Program v.4.1 Zone Sizing Summary for AHU Calculation Months Jan to Dec Sizing Data Calculated No Zone Terminal Sizing Data required for this system. Zone 1 205 OFFICE 206 OFFICE 207 STAFF 209 CORRIDOR 1 1 1 1 Cooling Sensible •(MBH) 4.7 4.7 7.4 2.0 Time Load Jun 1000 Jun 1000 Jun 1000 Jun 1000 Flow (CFM► 220 220 347 92 Heating Load (MBH) 2.3 2.3 2.7 2.0 Floor Area ( g = : 169.0 169.0 195.0 303.0 1.30 1.30 1.78 0.30 04/28/2003 02:49PM Page 1 of 1 bar Project Name: Bricklayers 41 Prepared by: Sider & Byers Air stem Design Load Summary for IU -3 ZONE LOADS Window & Skylight Solar Loads Wall Transmission Roof Transmission Window Transmission Skylight Transmission Door Loads Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor »Total:Zone: Loads :::< Zone Conditioning Plenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coil Fans Duct Heat Gain / Loss ».Total;System Laads... ... Central Cooling Coil Central Heating Coil »:Total' Conditioning ': Key COOLING DATA AT Jul 1400 COOLING OA DB / WB . 04.5 °F / 64.6 °F Details 160 ft 362 ft 836 ft 160 ft 0 ft 21 ft 0 ft 0 ft 0 ft 953 W 267 W 500 W 8 0% / 0% 0% 0% 0% 879 CFM 120 CFM 879 CFM 0% DESIGN COOLING Sensible (BTU /hr) 6685 1154 2568 588 0 77 0 0 0 2979 867 1642 1648 0 0 0 18209 17498 0 0 0 0 928 0 0 0 18426 18426 0 ;:.18426 Latent (BTU /hr) 960 0 0 0 960 960 -680 280 281 281 ;Positive:values are clg `loads' .:; : Negative :values htg loads HEATING DATA AT DES HTG HEATING OA DB /. WB 23.0 °F / 19.2 °F Details 160 ft 362 ft 836 ft 160 ft 0 ft 21 ft 0 ft 0 ft 0 ft 0 0 0 0 0% 0 0 0 879 CFM 120 CFM 879 CFM 0% DESIGN HEATING Sensible (BTUIhr) 2386 1819 4512 0 592 0 0 0 0 0 0 0 0 0 0 • 9309 8907 0 0 0 0 5888 0 0 0 14795 0 14795 14795 Latent (BTUIhr) 0 0 0 0 0 0 0 Positive values are htg loads Negative values are clg Toads Hourly Analysis Program v.4.1 04/28/2003 02:49PM Page 1 of 1 I Project Name: Bricklayers 41 Prepared by: Sider & Byers System Sizing Summary for AH Air System Information Air System Name AHU4 Number of zones 1 Equipment Class CW AHU Floor Area 434.0 ft Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Calculation Months Jan to Dec Space CFM Coincident space Toads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil Toad 1.3 Tons Load occurs at Sep 1400 Total coil load 16.4 MBH OA DB / WB 82.5 / 63.8 °F Sensible coil load 15.3 MBH Entering DB / WB 78.1 / 64.3 °F Coil CFM at Sep 1400 741 CFM Leaving DB / WB 68.7 / 57.4 °F Max block CFM at Sep 1400 741 CFM Coil ADP 56.5 °F Sum of peak zone CFM 741 CFM Bypass Factor 0.100 Sensible heat ratio 0.996 Resulting RH 60 % ft 339.3 Design supply temp. 55.0 °F BTU /(hr -ft 35.4 Zone T -stat Check 1 of 1 OK Water flow @ 10.0 °F rise 3.07 gpm Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil Toad 11.8 MBH Load occurs at Des Htg Coil CFM at Des Htg 741 CFM BTU /(hr -ft 27.2 Max coil CFM 741 CFM Ent. DB / Lvg DB 63.9178.9 °F Water flow @ 20.0 °F drop 1.18 gpm Supply Fan Sizing Data Actual max CFM at Sep 1400 741 CFM Fan motor BHP 0.00 BHP Standard CFM 729 CFM Fan motor kW 0.00 kW Actual max CFM /ft 1.71 CFM /ft Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 90 CFM CFM /person 15.00 CFM/person CFM /ft 0.21 CFM /ft Hourly Analysis Program v.4.1 04/28/2003 02:49PM Page 1 of 1 Zone Name / Space Name .:: Mult. Cooling Sensible , (MBH) ; ;. Time of Load : Air Flow (CFM► i Heating Load ( MBH) Floor Area (ft') Spa CFM /ft? Zone 1 Cooling :. Air Air ` of 204 OFFICE 1 9.1 Sep 1400 430 5.2 252.0 1.71 203 OFFICE 1 6.6 Sep 1400 311 2.3 182.0 1.71 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Coincident space loads Zone Sizing Data Zone Terminal Sizing Data Space Loads and Airflows Hourly Analysis Program v.4.1 Zone Sizing Summary for AHU- Calculation Months Jan to Dec Sizing Data Calculated No Zone Terminal Sizing Data required for this system. 04/28/2003 02:49PM Page 1 of 1 Maximum > Design : Minimum Time . ; Maximum : Zone Cooling :. Air Air ` of Heating ;: Floor Sensible Flow Flow Peak Load Area Zone Zone Name (MBH) :: ; (CFM) (CFM Load (MBH) '' `(ft') CFMlft° Zone 1 15.8 741 741 Sep 1400 7.4 434.0 1.71 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Coincident space loads Zone Sizing Data Zone Terminal Sizing Data Space Loads and Airflows Hourly Analysis Program v.4.1 Zone Sizing Summary for AHU- Calculation Months Jan to Dec Sizing Data Calculated No Zone Terminal Sizing Data required for this system. 04/28/2003 02:49PM Page 1 of 1 Project Name: Bricklayers 41 Prepared by: Sider & Byers ZONE LOADS Window & Skylight Solar Loads Wall Transmission Roof Transmission Window Transmission Skylight Transmission Door Loads Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor Total :ZoneLoads Zone Conditioning Plenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coil Fans Duct Heat Gain / Loss >y:TotalSystem Loads Central Cooling Coil Central Heating Coil Total: Conditioning Key: DESIGN COOLING COOLING DATA AT Sep 1400 COOLING OA DB / WB 82.5 °F / 63.8 °F Details 156 ft 315 ft 447 ft 156 ft 0 ft 0 ft 0 ft 0 ft 0 ft2 562 W 217 W 364 W 6 0% / 0% 0% 0% 0% 741 CFM 90 CFM 741 CFM 0% Sensible (BTU /hr) 8806 752 913 385 0 0 0 0 0 1759 706 1196 1236 0 0 0 15763 14795 0 0 0 0 475 0 0 0 15270 15270 0 15270 Latent (BTU /hr) 720 0 0 0 720 720 -641 79 81 81 • Positive: values are clg loads :.. Negative values are h loads. load DESIGN HEATING HEATING DATA AT DES HTG HEATING OA DB / WB . 23.0 °F / 19.2.°F : Details 156 ft 315 ft 447 ft 156 ft 0 ft O ft 0 ft 0 ft 0 ft2 0 0 0 0 0% 0 0 0 741 CFM 90 CFM 741 CFM 0% Sensible (BTUIhr) 2076 972 4385 0 0 0 0 0 0 0 0 0 0 0 0 7433 7358 0 0 0 0 4452 0 0 0 11810 0 11810 >11810 Latent (BTUfhr) 0 0 0 0 0 0 0 Positive values are htg Toads Negative values are cig loads Hourly Analysis Program v.4.1 Air stem Design Load Summary for 1U -4 04/28/2003 02:49PM Page 1 of 1 Project Name: Bricklayers 41 Prepared by: Sider & Byers System Sizing Summary for Ah Air System Information Air System Name AHU-6 Number of zones 1 Equipment Class CW AHU Floor Area 796.0 ft Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil Toad 2.2 Tons Load occurs at Aug 1600 Total coil load 26.5 MBH OA DB / WB 84.5 / 64.8 °F Sensible coil load 26.2 MBH Entering DB / WB 78.1 / 64.3 °F Coil CFM at Aug 1600 1260 CFM Leaving DB / WB 68.6 / 67.2 °F Max block CFM at Jul 1700 1260 CFM Coil ADP 66.4 °F Sum of peak zone CFM 1260 CFM Bypass Factor 0.100 Sensible heat ratio 0.987 Resulting RH 50 % ft 360.5 Design supply temp. 56.0 °F BTU /(hr -ft 33.3 Zone T -stat Check 1 of 1 OK Water flow @ 10.0 °F rise 6.30 gpm Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil Toad 20.4 MBH Load occurs at Des Htg Coil CFM at Des Htg 1260 CFM BTU /(hr -ft 25.7 Max coil CFM 1260 CFM Ent. DB / Lvg DB 63.9 / 79.1 °F Water flow @ 20.0 °F drop 2.04 gpm Supply Fan Sizing Data Actual max CFM at Jul 1700 1260 CFM Fan motor BHP 0.00 BHP Standard CFM 1239 CFM Fan motor kW 0.00 kW Actual max CFM/ft 1.58 CFM /ft Fan static 0.00 in wg 04/28/2003 02:49PM Outdoor Ventilation Air Data Design airflow CFM 160 CFM CFM /person 15.00 CFM /person CFM /ft 0.19 CFM/ft Hourly Analysis Program v.4.1 Page 1 of 1 Zone" Name / Space Mult Coo ling ' ;::.(MBH) ; Time of Load '. :: r Flow (CF■) eating Load . (MBH) .. Floor Area (ft') Space ?> CFM /if' Zone 1 Maximum Heating ; Zone Floor Sensible 201 LOBBY 1 15.0 Jul 1700 708 7.3 481.0 1.47 202 CONF 1 11.7 Jul 1700 552 5.9 315.0 1.75 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space Toads Zone Sizing Data Zone Terminal Sizing Data Space Loads and Airflows Hourly Analysis Program v.4.1 Zone Sizing Summary for AHU -! Calculation Months Jan to Dec Sizing Data Calculated 04/28/2003 02:49PM No Zone Terminal Sizing Data required for this system. Page 1 of 1 Maximum Cooling Des gn Air < :: • Mi nimum Air Time of ; Maximum Heating ; Zone Floor Sensible Flow . Flow Peak :: Load Area :: :':Zone Zone. Name . :. :(MBH) (CFM) :. (CFM■ ...:.: ;:`Load .OMBH) (tt?) :CFMIit2 Zone 1 26.8 1260 1260 Jul 1700 13.2 796.0 1.58 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space Toads Zone Sizing Data Zone Terminal Sizing Data Space Loads and Airflows Hourly Analysis Program v.4.1 Zone Sizing Summary for AHU -! Calculation Months Jan to Dec Sizing Data Calculated 04/28/2003 02:49PM No Zone Terminal Sizing Data required for this system. Page 1 of 1 Project Name: Bricklayers 41 Prepared by: Sider & Byers Hourly Analysis Program v.4.1 Air , stem Design Load Summary for AU-5 ZONE LOADS Window & Skylight Solar Loads Wall Transmission Roof Transmission Window Transmission Skylight Transmission Door Loads Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor »:Total Zone: Loadss: < Zone Conditioning Plenum Wall Load Plenum Roof Load Plenurn Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coil Fans Duct Heat Gain / Loss »Total:Syster• Loads. Central Cooling Coil Central Heating Coll » Total; Conditioning Ke y DESIGN COOLING COOLING DATA AT Aug 1600 COOLING OA DB / WB 84.0 °F / 64.8 °F Details 308 ft 423 ft 796 ft 308 ft 0 ft 0 ft 0 ft 0 ft 0 ft 824 W 158 W 200 W 10 0 % /0% 0% 0% 0% 1260 CFM 150 CFM 1260 CFM 0% Sensible (BTU /hr) 16924 900 1637 1211 0 0 0 0 0 2606 516 660 2091 0 0 0 26544 25011 0 0 0 0 1149 0 0 0 26160 26160 0 26160 Latent (BTU /hr) 1200 0 0 0 1200 1200 -862 :338 339 339 Positive values are clg loads Negative values are htg loads DESIGN HEATING HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F Details 308 ft 423 ft 796 ft 308 ft 0 11 0 ft 0 ft 0 ft 0 ft 0 0 0 0 0% 0 0 0 1260 CFM 150 CFM 1260 CFM 0% Sensible (BTU/hr) 2789 1731 8672 0 0 0 0 0 0 0 0 0 0 0 13192 13025 0 0 0 0 7397 0 0 0 20422 0 20422 20422 Latent (BTU/hr) 0 0 0 0 0 0 0 Positive values are htg loads Negative values are clg Toads 04/28/2003 02:49PM Page 1 of 1 Project Name: Bricklayers 41 Prepared by: Sider & Byers System Sizing Summary for AH Air System Information Air System Name AHU-6 Number of zones 1 Equipment Class CW AHU Floor Area 1271.0 ft Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 1.5 Tons Load occurs at Jun 1300 Total coil load 18.0 MBH OA DB / WB 82.0 / 64.4 °F Sensible coil load 16.9 MBH Entering DB / WB 78.3 / 64.7 °F Coil CFM at Jun 1300 798 CFM Leaving DB / WB 68.4 / 67.1 °F Max block CFM at Jun 1300 798 CFM Coil ADP 66.2 °F Sum of peak zone CFM 798 CFM Bypass Factor 0.100 Sensible heat ratio 0.937 Resulting RH 61 % ft 845.7 Design supply temp. 55.0 °F BTU /(hr -ft 14.2 Zone T -stat Check 1 of 1 OK Water flow @ 10.0 °F rise 3.61 gpm Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil Toad 11.6 MBH Load occurs at Des Htg Coil CFM at Des Htg 798 CFM BTU /(hr -ft 9.1 Max coil CFM 798 CFM Ent. DB / Lvg DB 59.2 / 72.9 °F Water flow @ 20.0 °F drop 1.16 gpm Supply Fan Sizing Data Actual max CFM at Jun 1300 798 CFM Fan motor BHP 0.00 BHP Standard CFM 786 CFM Fan motor kW 0.00 kW Actual max CFM /ft 0.63 CFM /ft Fan static 0.00 in wg 04/28/2003 02:49PM Outdoor Ventilation Air Data Design airflow CFM 180 CFM CFM /person 15.00 CFM /person CFM/ft 0.14 CFM /ft Hourly Analysis Program v.4.1 Page 1 of 1 Zone Name / Space Name " : "Muit Cooling Sensible (MBH) Time .. of Load Air Flow (CFM) Heating Load >. .:: (MBH) Floor Area : (ft') Zone :: CFM/ft Space CFMlft2 Zone 1 798 798 Jun 1300 2.8 1271.0 0.63 211 WOMEN 2 1.8 Jun 1300 85 0.6 273.0 0.31 213 DILBERTVILLE 1 13.3 Jun 1300 628 1.6 725.0 0.87 Zone Name Maximum Cooling Sensible : ::: ; Design Air Flow (CFM) Min mum -Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) ::: Zone Floor ::; Area , : (ft Zone :: CFM/ft Zone 1 17.0 798 798 Jun 1300 2.8 1271.0 0.63 Project Name: Bricklayers 41 Prepared by: Sider & Byers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Coincident space Toads Zone Sizing Data Zone Terminal Sizing Data Space Loads and Airflows Zone Sizing Summary for AHU -t Calculation Months Jan to Dec Sizing Data Calculated No Zone Terminal Sizing Data required for this system. 04/28/2003 02:49PM Hourly Analysis Program v.4.1 Page 1 of 1 z W ce "U0• fn0• co = J W O. u_ Q S W ZH I— 0 Z F--: tIJ U� O 0 I— w W. H U. • w H .0 ~ • z Project Name: Bricklayers 41 Prepared by: Sider & Byers Hourly Analysis Program v.4.1 Air , stem Design Load Summary for .IU -6 ZONE LOADS : :; Window & Skylight Solar Loads Wall Transmission Roof Transmission Window Transmission Skylight Transmission Door Loads Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor >:Total Zone Loads::::: >;. Zone Conditioning Plenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coil Fans Duct Heat Gain / Loss »Total System Loads::::: Central Cooling Coil Central Heating Coil >Total Conditioning Key: ::: DESIGN COOLING COOLING DATA AT.Jun 1300 COOLING OA DB / WB 82.0 °F / 64.4 °F Details 0 ft' 0 ft 1271 ft' 0 ft' 0 ft' 0 ft 0 ft' 0 ft 0 ft' 1411 W 363 W 1450 W 12 0% / 0% 0% 0% 0% 798 CFM 180 CFM 798 CFM 0% Sensible (BTU /hr) 0 0 4068 0 0 0 0 0 0 4385 1175 4750 2585 0 0 0 >16964 16001 0 0 0 0 899 0 0 0 16900 16900 0 . 16900 Latent (BTU /hr) 2290 0 0 0 2290 2290 -1156 1134 1134 .1134 Positive.;valuessre clg Toads .Negative valuesare htg loads DESIGN HEATING HEATING DATA AT DES HTG... • HEATING.OA:DB / WB . 23.0 °F 119.2 °F • Details 0 ft' 0 ft' 1271 ft 0 ft 0 ft 0 ft' 0 ft2 0 ft 0 ft' 0 0 0 0% 0 0 0 798 CFM 180 CFM 798 CFM 0% Sensible (BTU/hr) 0 2765 0 0 0 0 0 0 0 0 0 0 0 0 2766 2681 0 0 0 0 8933 0 0 0 11614 0 11614 11614 Latent (BTU /hr) 0 0 0 0 0 0 0 0 Positive values are htg Toads Negative values are clg loads 04/28/2003 02:49PM Page 1 of 1 09 -08 -2005 LAIRD DONALDSON 6770 EAST MARGINAL WY S SEATTLE WA 98108 RE: Permit No. M03 -128 15208 52 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow.the.Building Official to approve a one - time extension up to 180 daps. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/15/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Brenda Holt, Permit Coordinator xc: Permit File No. M03 -128 Bob Benedicto, Building Official City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 - 431 -3665 n NEWTON ASSOCIATES ARCHITECTS 12213 DENSMORE N. SEATTLE, WASHINGTON 98133 (206) 363.5806 May 11, 2004 Stephania Spencer Department of Community Development City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Re: Request for Mechanical Permit Extension Project Name: Bricklayers Union Hall Building Permit Number: D03 -246 Mechanical Permit Number: M03 -128 Project Address: 15208 52 Ave S Dear Stephania, Per your request I am sending this letter to request an extension on the mechanical permit for the Bricklayers Union Hall construction project. The current permit will expire on June 7, 2004 and yet the mechanical portion of the construction is not scheduled until sometime in late June. Your help in this process will be greatly appreciated. Please let me know if you need additional information. Thank you. Yours truly, oaeite4-a- ?///60-4-, Margaret R. Newton, A.I.A. / /c)4 May 5, 2004 Laird Donaldson 6770 East Marginal Way South Seattle, WA 98108 RE: Permit Application No. M03 -128 15208 52nd Avenue South Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Sincerely, Stefania Spe Permit Technician Xc: Permit File No. M03 -128 Bob Benedicto, Building Official City of Tukwila Department of Community Development Steve Lancaster, Director • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to June 7, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 April 20, 2004 Margaret R. Newton, A.I.A. Newton Associates Architects 12213 Densmore North Seattle, Washington 98133 RE: Request for Extension — Permit No. M03 - 128 — Bricklayers Union Hall Dear Ms. Newton: This letter is in response to your written request for an extension to Permit No. M03 -128. Based on the information received, the City of Tukwila Building Division will be extending your permit to November 5, 2004. Please be advised that this will be the only extension granted for this project and no further notice will be Qiven prior to the expiration date. A new permit and associated fees will be required after the above -noted expiration date. If you should have any questions, please contact our office at (206) 431 -3670. Robert Benedicto Building Official /sks File: Permit No. M03 -128 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M03 -128 DATE: 04 -08 -04 PROJECT NAME: BRICKLAYERS UNION HALL SITE ADDRESS: 15208 52 AVENUE SOUTH Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # 1 iafteN€e permit is issued D PARTMENTS: 4 -13 ��' Buil ing !vision gi Public Works ❑ PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ci Fire N Pre enion 0 13 Structural ❑ REVIEWER'S INITIALS: Documents /routing slip.doc 2-28-02 Planning Division Permit Coordinator DUE DATE: 05-11-04 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -13 -04 Complete [d Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4 ' aU'O4 El Response to Incomplete Letter # Response to Correction Letter # 54 Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: '1V,\ c' 1� 1 . Ce (A, -ei1/' c, 0 IA I NA t4(A ij Project Address: t S 20 P) 4.0 Sac_, Contact Person: IAMi q (lift -e j\) -•Q,t j c- Phone Number: 20 (Q ' (a 7 ) • G © Cp Summary of Revision: )-e-e a 176 (,, --C c�I RECEIVED A PR_ 2O PERMIT CENTER Sheet Number(s): VA(9 , , t , 1 7, 7 2 7. ' "Cloud" or highlight all area? of revision /ncludink date of I►evision Received at the City of Tukwila Permit Center by: b,---- Entered in Permits Plus onL -S - Ott' Plan Check/Permit Number: (M (7 2,— V 2.2 08/06/03 ACTIVITY NUMBER: M03 -128 DATE: 08 -13 -03 PROJECT NAME: BRICKLAYERS UNION BUILDING SITE ADDRESS: 15208 52 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After permit Is Issued DEPARTMENTS: Building Division P Public Works 0 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP � At0e, Fire Pfevention ® Planning Division ❑ Structural ❑ Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08 -14 -03 Complete [ Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROJSTING: Please Route IGEf Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 09 -11 -03 Approved ❑ Approved with Conditions [i Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2.28.02 PERMIT COORD COPY z a• w re g _i 00 roc cn 1 CO u_ w u.? d =w Z � I- 0 Z F- U w O - oI- w w 1- O .Z W U O z Revision No.. Staff Received � I Date j Initials Date .. Issued Staff Initials I I I Summary of Revision: Summary of Revision: Received By: Revision No. Date Received I Staff Initials I Date Issued Staff Initials Summary of Revision: Received By: Revision • No. Summary of Revision: Revision I No. Summary of Revision: PROJECT NAME: f i PERMIT NO:. /Zf Site Address: /5211# S Origh...1 Issue Date: REVISION LOG Date Received yeoy Date Received Staff Initials I Staff I Initials Received By: Received By: Date Issued Date Issued iplease print) (please print) (please print) 'Staff Initials Staff Initials p l ease pn Revision No. Date Received I Staff Initials Date ! Staff Issued 1 Initials Summary of Revision: Received By: 1 (please print) z _* w are i0 00 N 0 N u- WO 2 u-? � Z = ►- O Z U u) O N OH w �J LL z w U = O~ z AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON COUNTY OF KING AFFCONT 1/13/00 CITY OF ' 'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 ss. 7 iJ i Ro 6 s , states as follows: 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. � Ge , p ' ,:-.- Q- \S A S%ON F . L •, i ; o 0OTAR l m ; o i U iwo, Uf ' y Q . 1 16 11 � WAS` APPLICANT Signed and sworn to before me this 1 U day of 0r Ci. H -4 , 20 n •3 NOTARY PUBLIC in and fbr the State of Washington, residing at ki j County. Name as commissioned: A /iCe. A..Na.cy My commission expires: 6"16 -04 + BRICKLAYERS AND ALLIED CRAFTWORKERS INTERNATIONAL UNION NEW MEETING HALL AND ADMINISTRATIVE OFFICE BUILDING t • • AAG AB ACOUS ACT AD ADD ADJ ADJ ADMIN AFF ALT ALJM AMEND APROx ARCH AUTO BD BIT BKT BLDG BLKG BM BO BOF BOT BRG BSMT BTYVN BUR GAB GANTL GJT GLG CLR CMU COL CONC.; GONF CONN GONST GONT CON COORD GORR GPT GT GTR CTSK D DEMO DEPT DF DIA DiAG D,I DIV DN DR D5 DWG 17WLS EA EF EIFS EJT ELEV ELE EMERG ENCL ENTR EO EQ EQUIP EINC EXG EXIST EXP EXT FD FDN FE FN FAQ! FIXT FL 2F RIPTI And AT Pound/ Number Degree AUTOCLAVED AERATED CONCRETE ANCHOR BOLT ACOUSTICAL ACOUSTICAL CEILING TILE AREA DRAIN ADDENDUM ADJUSTABLE ADJACENT ADMINISTRATION ABOVE FINISH FLOOR ALTERNATE ALUMINUM AMENDMENT APPROXIMATE , ARCHITECTURAL /ARCHITECT AUTOMATIC BOARD BITUMINOUS BRACKET BUILDING . BLOCKING BEAM BY OWNER 5 ' OWNER FUTURE BOTTOM BEARING BASEMENT BETWEEN BUiLT-UP ROOFING CABINET CANTILEVER CONTROL JOINT CENTER LiNE CEILING CLEAR CONCRETE MASONR" UNIT COLUMN CONCRETE CONFERENCE GONNEGT /- ED / -iON CONSTRUCTION GONTNUE /OUS CONTRACT /OR COOP PNATE CORR :DOR CARPET CERAMIC TILE CENTER COUNTERSUNK DEPTH OR DEEP DEMOLITION DEPARTMENT DRINKING FOUNTAIN DIAMETER DIAGONAL DIMENSION DIVISION DOWN POOR DOWNSPOUT DRAWING DOWELS EXISTING EACH EXHAUST FAN EXTERIOR INSULATION AND FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRICAL EMERGENCY ENCLOSURE ENTRANCE ELECTRICAL OUTLET EQUAL EQUIPMENT ELECTRIC WATER COOLER EXCAVATE / -ED/ -ION EXISTING EXPANSION EXTERIOR FLOOR DRAN FOUNDATION FiRE EXTINGUISHER FIRE HOSE FINISH FIXTURE FLOOR le ASSREVIATIONS MARCY FLASH FLEX FLUOR FP PRMG F5 FSTOP FT FT& PURR FUT GA ALV GB GC GEN GL GMU GR .CAI B H HB HDGP HDR HOW HM HORIZ HR HT HVAG HIND ID N I' SUL tT ISO JAN JST JT L LAV LB LSS LIN LT LTG M MAN MATL MAX MEGH MEMB MEZZ MFR MH MIN Me:G MO MTL MTD MULL NA NIC NO NOM NT NTS OD OFF OH OPNG OPP PART PG PED PL PLAM PLS PLWD PR PRELIM PRESS PRM PROJ PT PVC R RB • PESCRIPTION FLASHING FLEXIBLE FLUORESCENT FIRE PROOFING FRAMING FLOOR SINK FIRESTOPPING FOOT /FEET FOOTING PURRING FUTURE GAUGE GALVANIZED GRAB BAR GENERAL CONTRACTOR GENERAL GLASS GLASS MASONRY UNIT GRADE GYPSUM WALLBOARD HEIGHT /HIGH HOSE BIB HANDICAP HEADER HARDWARE HOLLOW METAL .HORIZONTAL 1-HANDRAIL HEIGHT HEATING, VENTILATING, AIR CONDITIONING HARDWOOD INSIDE DIAMETER INCH INSULATION INTERIOR ISOLATION JANITOR JOIST JOINT LONG LAVATORY POUND POUNDS (WIEGHT) LINEAR LIGHT LIGHTING MIDDLE MANUAL ' MATERIAL MAXIMUM MECHANICAL MEMBRANE MEZZANINE MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MASONR" OPENING METAL MOUNTED MULLION NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOTE NOT TO SCALE ON CENTER OUTSIDE DIAmETER OFFICE OVERHEAD OPENING OPPOSITE PARTITION PRECAST CONCRETE PEDESTAL PLATE PROPERTY LiNE PLASTIC LAMINATE PLASTER PLYWOOD PAIR PRELIMINARY PRESSURE PRI•ARY PROJECTION PAINT POLYVINYL CHLORIDE OVA TILE RADiUS RISER RESILIENT BASE SCHED y ; « SD SECT .1 SF 5H •• 7 SHT SHTG AIM SLV 5M SOG 5P SPEC 50 • 5Q YD • 55 55T ST ST 5TG STD j 5TL STN ,t�! STOR • r STRUC,T SUPV ' Iw,UsP 5W 4 6WD 5YM T TAN TEL TEMP TER TG THRES 7 TRANSF •7V TYP U s UNFIN ' .UNO $6. UTIL VENT VERT VEST fN W/0 WG WD rDW IM P WSGT WT AWF • ABF3REV %REG REF REFR ` REM `'REOD RET Rf *RFI .. RM 4 RO • 15208 52nd Avenue South, '.Tukwila, Washington ,DESCRIPTION ROOF DRAIN RECESSED REFERENCE REFRIGERATOR REINFORCE /- ED / -ING REMOVE REQUIRED RETAINING RESILIENT FLOOR ROOM ROUGH OPENING SINK /SUPPLY FAN SCHEDULE SMOKE DAMPER SECTION SQUARE FOOT SHOWER SHEET SHEA S TH N SEALANT SLEEVE SURFACE MOUNTED SLAB ON GRADE STANDPIPE SPECIFICATIONS . • SQUARE SQUARE YARD SERVICE SINK STAINLESS STEEL t - STREET STONE TILE SOUND TRANSMISSION STANDARD STEEL STONE STORAGE STRUCTURAL SUPERVISOR SUSPENDED SWITCH SOFTWOOD SYMMETRICAL TOP ; TANGENT TELEPHONE TEMPERATURE TERRAZZO TONGUE 4 GROOVE THRESHOLD TREAD TRANSFORMER TELEVISION TYPICAL URINAL UNFINISHED UNLESS NOTED OTHERWISE UTILITY VENTILATION VERTICAL VESTIBULE (WIDTH /WIDE SMITH ,WITHOUT WATER CLOSET "4OOD WINDOW WATERPROOF WAINSCOT WEIGHT WELDED WIRE FABRIC Dimension Notes � los score Of WO* P417312147.M. Of 1Utivo.A 111A711,11110- 014111,01. Not p4 veil ' DO NOT SCALE DRAWiNGS!! .GenerQi Notes 1. Proir to beginninge construction, review and compare related drawin and report any conflicts or omissions to the Architect. 2. Prior to and throughout construction, verify existing condidions and dimensions relating to the Work. Report ' changes or discrepencies to the Architect. 5. Check with Owner prior to making any openings in walls, ceilings, roofs, floors, or structural members, to accomodate installation of pipes, .conduits, ec,iuipment and other utilities. . 4. Perform or work in compliance with all .applicable codes and Ordinances. 1. Unless noted otherwise dimensions are to: • . • Exterior face of veneer at exterior wale • Face of masonr at interior 1"v011s • Centerline of columns 2. Where a dimension needs verification, an ad justment shall be accommodated in the adjacent +/- dimension. 3. Written dimensions and notes have precedence over drawings. 4. Larger scale drawings have precedence over smaller scale drawings. Masonry Notes 1. Brick Veneer: modular units in color blend to be selected. Anchor to CMU backing with ties per structural notes. 2. Concrete Masonry Units (CMU): unit . • sizes as shown. Bond beams, reinforcing and grouting per structural notes. . . 3. Autoclaved Aerated Concrete Block (AAC): Light weight units in sizes as shown to be used in interior, non -load- bearing partition walls. Use thin -bed mortar at joints and provide control joins such that no straight run of wall exceeds 20'. Use manufacturer recommended fasteners when anchoring materials and /or fixtures to the AAC block. •Where • interior brick veneer occurs, anchor to AAC backing with surface- mounted veneer anchors using fasteners recommended by AAC manufacturer. 4. Glass Masonry Unit (GMU): unit sizes .as shown for interior sidelight application. 5. Rubble Stone Veneer: at front courtyard retaining walls. Anchor to GMU backing per structural notes. b. Expansion Joints: =,• Provide vertical expansion joints rear building corners, highly restrained walls and in lar a walls with no openings or discontinuities, and to isolate significant Changes in panel geometry isuch as door and window openings), material chop es, walls of different thickness, height or base height, and ad jac,ent walls with .substantially different weather exposures. • !Provide horizontal expansion joints below supporting ledgers and similar constraints to vertical expansion and below window sills, windows, louvers ono similar elements secured to the primary structure. ,FILE CQPY understand that tae P8n Check approvals ere subject lo errors and omissions and approval of adopted does n authorize the violation of any Or ordnance. Receipt of con- tractors copy of approved plant ack • t TABU OF CONTENTS SHEET DESCRIPTION A1.1 A1.2 A13 A1.4 A2.1 A2.2 A3.1' A5.2.1 A3.2.2 A3.2.3 A3.3.1 A33.2 A3.3.3 A3.3.4 A3.3.5 A3.4.1 A3.4.2 A3.4.3 A4.1 A4.2 A4.3 A5.1 A5.2 A5.3 A6.1 A - 7.1 A - 7.2 A - 7.3 AS.1 AAC .STUDS * GWB GMU BRICK RUBBLE STONE GLASS BLOCK 1. , • SITE PLAN BASEMENT : LCOR PLAN, WINDOVN SCHEDULE FIRST FLOG F? PLAN, DOOR SCHEDULE FIRE RESISTIVE. CONSTRUCTION PLANS BUILDING ELEVATIONS . EXTERIOR FEATURES . BUILDING SEC.,TIONS • • STAIRS: C LANS 4 SECTIONS ELEVATOR: PLANS 4 SECTIONS ENLARGED FLANS .WALL SECTIONS-EXTERIOR WALL SECTIONS- EXTERIOR NALL SECTIONS- EXTERIOR WALL SECTIONS- EXTERIOR WALL SECTIONS - INTERIOR ,DETAILS - BRICKS • DETAILS - STAIRS 0 DETAILS - MISC } TOILET ROO "/ 3: FLANS t ELEVATIONS INTERIOR ELrw IATIONS -MTG 1 -BALL, ADMINISTRATIVE OFFICE'S INTERIOR EL! '/ATIONS- LOBBIES ROOF PLAN ROOF DE + AL...S ... . ROOT' 4 ROOF DECK DETAILS .REFLECTED CEILING PLANS 1110 DOOR DETAILS - BASEMENT DOOR DETAILS -FIRST FLOOR DOOR DETAILS-INTERIOR WINDOW DETAILS 1'. GRAPHIC STANDARDS » DOOR NUMBER 25 ' WINDOW NUMBER 1 DETAIL AREA SYMBOL AREA SHOWN IN DETAIL SECTION RE SHEET REFERENCE WALL 'SECTION SYMBOL 4 . 0 DETAIL REFERENCE SHEET REFERENCE B UILDING SECTION SYMBOL • 4 N sat z to NEWTON ASSOCIATES ARCHITECTS 12213 DENSMORE AVE. N. SEATTLE, AA d e133 206? 363 -5806 (206) 364 -74 r AX Iier tonA knot 1 PATE: DESIGN REVIEW: AUGUST 14. 2002 D.R RESUBtITTALS: NOVEMBER 11. 2002 JANUARY 13, 2003 PRO&RESS SFr: '1/q /03 PERMIT SET: b/s/o3 MY OF TUKINILA AUG 1 2 1003 Plow ciTIR i A 0.0 Md3-1,21 ...:,:�,... un ..... .�.iw.....Mrww ..+..wr.. «�. ♦ 1:6 j+L...� ;) 't'i'p y tM► +� �• '' -�R 4 • • VICINITY PLAN LEGAL DESCRIPTION TAX PARCEL NUMBER 115720 - 0010 - 03 PROJECT DESCRIPTION JURISDICTION BUILDING CODE ZONING SITE AREA BUILDING FOOTPRINT GROSS BUILDING AREA OCCUPANCY CONSTRUCTION BUILDING HEIGHT ALLOWED BUILDING HEIGHT PROPOSED FIRE PROTECTION PARKING REQUIRED PARKING PROPOSED IMPORTANT NOTE: CIVIL ARE FOR INFORMATIONAL NO SCALE EXISTIN6 SIDEWAL BASEMENT: ANIC EQUIPMENT RETAN'6 WALL 20' -0 L DIP SLEEVE FOR 6'PVG 1 TRASH AND RECYCLN6 BELOW O 6V PVC -D•2% • MN' 24' -0" 21 -0 6' PVC SD •2%SIMN DIP SLEEVE DI BICYCLE RACK (GAP. 5 PVC 50 15t5 SL MM 120 -0" CONNECT TO BLD VERIFY SIZE OF WITH BLD& AND CITY 17 x 17 YA • DRAN CONNECT 6' PVC • 2% 1 tin YARD MAN (17 X 7) LRAILI r . ,� , •� �� (GOORUMATE W/ mai imioxig V►ND,�GAPE ARC.H EXISTING P _ VAULT. VERIFY LOCATION R HANIC 6" PVC. SD WO 5.8% SL • 12' -0" 4" FIRE PROTECTION MATER EXISTN6 STREET L_I6HT SANITARY SEWER MANHOLES PROPERTY SETBACK IJNES EXISTIN6 FIRE HYDRANT E) JSTN6 WATER VALVES EXISTN6 CITY OF TUKWILA UNIFORM BUILDING CODE - 1997 EDITION 0 - OFFICE 47, 576.04 SF (1.09 ACRES) 5,568 SF TOTAL 12,657 SF MIXED -USE: FIRST FLOOR: • 0' NEW SIDEWALK ALAN YV/ EXISITN6 ABANDON EXIST GB AND REMOVE GPEP PROM UNDER PROPOSED PARKI'6 LOT THAT PORTION OF TRACT 1, BROOKVALE GARDEN TRACTS, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 10 OF PLATS, PAGE (S) 47, IN KING COUNTY, WASHINGTON, LYING EASTERLY OF 52ND AVENUE SOUTH; EXCEPT THE SOUTH 51 FEET; AND EXCEPT THAT PORTION THEREOF CONDEMNED IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 596231 FOR PRIMARY STATE HIGHWAY NO. 1 B - OFFICE (4,953 SF GROSS) A - DIVISION 2.1 - ASSEMBLY (600 SF GR) A - DIVISION 2.1 - ASSEMBLY (5,024 SF GR) B - OFFICE STORAGE /BLDG MAINT 42,062 SF GR) GROUP A: TYPE V - 1 HOUR GROUP B: TYPE V - NON RATED 35'- 0" 20'- 0 3/4" FULLY SPRINKLERED 40 STALLS TOTAL: OFFICE : (5, 553 SF /1000) x 3 16.7 STALLS ASSEMBLY:2,342 SF / 100 • 23.4 STALLS 51 STALLS (34 FULL + 15 COMPACT + 2 ADA) UTILITIES (STORM SEWER, SANITARY SEWER AND WATER) SHOWN ON THIS SHEET PURPOSES ONLY. DO NOT USE THE UTILITY DESIGNS SHOWN ON THIS PAGE sil'er ' • EXIST1N6 WREN6 PROPERTY LNES y EXI5TN6 CHANV 9 LINK FENCE �i' 7 Ii PARALLEL PAR s6 6" 7 �--- EXISTN& CATCH BASIN i AP EX. 8' WATER MAN TERUNE OF STREET EXISTN6 MANHOLE 52nd AVENUE SOUTH TELEPHONE MANHOLE SITE PLAN NORTH me 7 = 20' O O 1 1 1 —vow; EX CB CAN BE MOVED ,(4SDOT) 1 50UTN AS WAN REMOVE 17 GPCP PPE ' fi SS PVC, 192% SL MN NEW WM 20 - 1JI OM VW UMW INMPIIIIIPIP NEW DRIVEWA s 'ieMIMI REMOVE EXISITN& C.UR5IN6 AT NEW DRIVEWAY GB, n 4fPE 1 IMPORTANT NOT CIVIL UTILJTES (SANITARY AND STORM SEWERS, WATER PIPING.) SHOWN ON THIS SHEET ARE FOR INFORMATIONAL PURPOSES ONLY. DO NOT USE THE CAVIL UTILITY LAYOUTS SHOWN ON THIS SITE PLAN FOR CONSTRUCTION PURPOSES. USE THE CAVIL ENC NEERN6 DRAAIN65. 1E0 DEC -5 l3 ps tow - 111a5 0- " rir EXISTN6 RETAINING WALL VERIF• .MMCT1ON CONNECTION PT WILL PROVIDE % SLOPE MN 8 " PVC: 5D• 2% SL MN rX►MH RAISE L%1 TO 1550 -0 '. 4 - 'e' (VERIFY) 3' WIDE SANITARY SEWER EASEMENT EXISTING BETA 146 WALL . TRANSFORMER X 1' X5' PROPERTY U S AU &N NEW W/ EXISTN6 SIDEWALK EXI5TN6 0 STREET L16HT CONNECT SAMTARY SEAM TO EXSTN6 5S STUB AND PROVIDE GLEANCVT (VERIFY D6Gr+AR6E F - ILL AGLOW FoR 2% SL MN FOR PROPOSED 5AN,TAR'' SEWER .INE5) EXIST SANITARY SEWER ENERGY CODE LEGEND THE HVAC SYSTEM IS BASED ON THE FOLLOWING CRITERIA COMPONENT: DESIGN: ROOF " U ' VALUE (BTUH /S.F. F) 0.036 WALL "U' VALUE (BTUH /S.F. F) 0.08 FLOOR "U" VALVUE (BTUH /S.f. F) 0.73 GLASS "U" VALUE (BTUH /S.F. F) 0.6 GLASS SHADE COEFFlCIENT 0.6 LIGHTING (WATTS /S.F.) 1.5 MISC. EQUIP. (TOTAL KILOWATTS.) PEOPLE (TOTAL) 266 COOLING INDOOR DESIGN TEMP. (F) 70 - COOUNG OUTDOOR DESIGN TEMP. (F) 85 DB 1 67 WB HEATING INDOOR DESIGN TEMP. (F) 70 HEATING OUTDOOR DESIGN TEMP. (F) 24 4: Si BLOWER COIL UNIT OPERATION GENERAL: SEVEN -DAY PROGRAMMABLE ROOM THERMOSTATS PROVIDE STAGED HEATING, COOLING, VENTILATION, AUTOMATIC CHANGEOVER FAN CONTROL AND NIGHT SETBACK. THERMOSTATS SHALL BE BASYS SZ 1017A SERIES OR APPROVED EQUAL. BCU- 1 I. FAN SHALL RUN CONTINUOUSLY DURING OCCUPIED HOURS. 2. OUTSIDE AIR ( ECONOMIZER) DAMPER SHALL OPEN TO MINIMUM SETPOINT DURING OCCUPIED HOURS AND CLOSE DURING UNOCCUPIED HOURS. 3 TWO STAGES OF COOLING SHALL SEQUENCE CONDENSING UNITS. 4 HEAT SIGNAL SHALL PROVIDE MODULATING CONTROL OF 2-STAGE DUCT FURNACE. 5. ECONOMIZER CONTROLS SHALL BE FULLY MODULATING WITH DISCHARGE AIR RESET. CHANGEOVER FROM MECHANICAL COOLING TO ECONOMIZER SHALL BE FULLY AUTOMATIC. ECONOMIZERS SHALL BE INTERGRATED TYPE , CAPABLE OF SIMULTANEOUS COMPRESSOR AND ECONOMIZER OPERATION. 6 RELIEF AIR DAMPERS SHALL BE FURNISHED WITH DIRECT COUPLED ACTUATORS AND SHALL BE SLAVED TO THE OPERATION OF OUTDOOR AIR DAMPEF'. DAMPERS ACTUATORS SHALL BE MODULATING TYPE. • 7 FAN OPERATION SHALL BE CONTROLLED BY A VFD PROGRAMMED FOR HIGH SPEED IN THE COOLING /ECONOMIZER MODE AND LOW SPEED IN THE HEATING MODE. EXACT RPM SET POINTS SHALL BE SET DURING AIR BALANCING. FURNACE UNIT OPERATION F-- I , F-2, F-3, F-4, F-5, F - 1.FAN RUNS CONTINUOUSLY DURING OCCUPIED HOURS. 2.MOTORIZED OUTSIDE AIR DAMPER SHALL BE FURNISHED WITH DIRECT COUPLED ACTUATORS. DAMPER SHALL BE FULL OPEN DURING OCCUPIED HOURS AND CLOSED DURING UNOCCUPIED HOURS. SET MANUALOUTSIDE AIR BALANCING DAMPER FOR MINIMUM CFM LISTED IN EQUIPMENT SCHEDULE. 3.A CALL FOR COOLING SHALL ENABLE THE CONDENSING UNIT. 4.A CALL FOR HEATING SHALL ACTIVATE 2 -STAGE GAS VALVE. ENTI-1APY SENSOR ECON DAMPER RELIEF DAMPER ECON. CONTROLLER LW MIN. SET PT, • Ti4ERMOSTAT BASYS MODEL SZ101lA 1 1 N.T.S. � � .r r 00 / GENERAL: THE FOLLOWING WORK SHALL BE CONSIDERED TO BE UNDER DIVISION 16: 1 ALL POWER WIRING FROM POWER SOURCE TO EQUIPMENT. 2 CHECKING CURRENT CHARACTERISTICS AND ROTATION OF ALL MOTORS. 3 FURNISHING AND INSTALLING DISCONNECT SWITCHES UNLESS `- SPECIFICALLY NOTED OTHERWISE. ti 4 FURNISHING AND INSTALLING ALL STARTERS. e . T HE FOLLOWING WORK SHALL BE CONSIDERED TO BE UNDER DIVISION 15: 1 ALL TEMPERATURE, INTERLOCK, AND EQUIPMENT CONTROL WIRING, CONDUIT, AND APPURTENANCES, HIGH AND LOW VOLTAGE. 2 ALL CONTROL WIRING, UNE OR LO'N VOLTAGE. INCLUDING BUT NOT LIMITED TO WIRING THROUGH THE COILS OF THE MAGNETIC STARTERS AND RELAYS, AND THROUGH THE CONTACTS OF THERMOSTATS AND OTHER PILOT DEVICES, EXCEPT WHERE NOTED OTHERWISE. . OWNER WILL NOT ENTERTAIN ADDITIONAL COSTS DUE TO LACK OF COORDINATION BETWEEN DIVISION 15 AND DIVISION 16 • OPY l linden htlld !hit th6 PIM Check apOliSiiii al in tc) ants end d'hlelibha plant datia hot dUthwite the vioiitf6h iity adopted code or ®rt'lifl r ci. RetAipt of con - I tractor'% ON 6 Witived pis acknowledged. By 4 • Dale Permit N o. -dAeM SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ELECTRICAL Wt PLUMBING (GAS PIPING CITY OF TUKWILA BUILDING DIVISION OUTSIDE AIR DX COIL IRN BCU 1 CONTROL DIAGRAM 5D t OtS ,, t o E9 SA S1 vie scope of * V�k Y' per;;VAL_Of I5CM4RE AIR TEMP SENSOR 20&V, 3PWWBYDIV16 120V BY DIV. 16 `Y GAS VALVE 120v/24v TRANSFOR1ER BY c Iv 15. SMOKE DETECTOR • JHIVAC GENERAL NOTES 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET, WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE MECHANICAL CODE, BUILDING CODE, UNIFORM FIRE CODE, ENERGY CODE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 10 OF THE 1997 MC AND WITH CURRENT SMACNA STANDARDS. 4. JOINTS OF DUCT SYSTEM SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. . 5. DUCTS SMALL BE INSULATED AS INDICATED ON PLANS TO MEET THE REQUIREMENTS OF THE 2001 W.S.E.C. AND SPECIFICATION SECTION 15250. 6. FLEXIBLE DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 6 FT IN LENGTH UNLESS NOTED OTHERWISE. x i 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 2.336 OF THE 1997 BC. 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOOR SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 9. PROVIDE SUPPLY DUCT SMOKE DETECTOR(S) FOR AUTOMATIC SHUT DOWN OF ALL I HEATING OR COOLING EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH THE 1997 MC. POWER WIRING AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 10. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS, UNLESS SHOWN ON ARCHITECTURAL DRAWINGS. REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE HVAC CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR. ENERGY CODE NOTES 1. SEE SCHEDULE FOR EQUIPMENT TYPE, CAPACITY AND EFFICIENCY. 2. PROVIDE THERMOSTAT CONTROLS CAPABLE OF A FIVE (5) DEGREE DEADBAND BETWEEN HEATING AND COOUNG. 3. PROVIDE AUTOMATIC SETBACK CONTROLS WITH NIGHT SETBACK AND SEVEN (7) DIFFERENT DAY TYPES. 4. PROVIDE DAMPERS FOR OUTSIDE AIR INTAKES AND EXHAUST FANS WHICH t. CLOSE AUTOMATTICALLY WHEN THE SYSTEM IS OFF, EXCEPT FOR THOSE . SYSTEMS WHICH OPERATE CONTINUOUSLY. 5. PROVIDE GAS -FIRED HEATING EQUIPMENT WITH MODULATING OR STAGED CONTROL FOR ALL EQUIPMENT OVER 225 MBH. 6. PROVIDE A MEANS OF BALANCING EVERY AIR SUPPLY OUTLET AND AIR OR WATER TERMINAL DEVICE. 7. SIMULTANEOUS HEATING AND COOLING IN A ZONE IS NOT PERMITTED. 8. SEAL TRANSVERSE AND LONGITUDINAL SEAMS OF ALL DUCTWORK. 9. DUCT INSULATION: SEE SPECIFICATION SECTION 15250. 1 0. PIPE INSULATION: SEE SPECIFICATION SECTION 15250. 1 1. ALL ELECTRIC MOTORS GREATER THAN 1.0 HP SHALL MEET WSEC TABLE 14--4 EFFICIENCY REQUIREMENTS. • s M 1 EXPIRES 2/16/06 I • r. • • ` COMM _IMBED F ........._C : _ RL OF D4 0 r . ' SYMBOL ABBRV OE tti OR OR r MECHANICAL SYMBOLS LEGEND iammommisamismanow VD SD S /FD VD BOO 00 OBD FCO WOO AFF NTS ss GSM EG CD VTR AP SA RA EA w w V MECHANICAL SHEET LIST MO.1 LEGENDS, NOTES 111.1 MECHANICAL EQUIPMENT SCHEDULES M2.1 LOWER LEVEL HVAC FLOOR PLAN M2.2 ENLARGED LOWER LEVEL PLAN M2.3 UPPER LEVEL HVAC PLAN M3.1 DETAILS P0.1 LEGEND. SYMBOLS AND SCHEDULES P2.0 FOUNDATION PLAN- PLUMBING P2.1 BASEMENT FLOOR PLAN- PLUMBING P2.2 FIRST FLOOR PLAN - PLUMBING P3.1 PARTIAL FLOOR PLAN, RISER DIAL P3.2 DETAILS • DESCRIPTION PLUMBING EQU I PMENT MECHANICAL EQUIPMENT DIFFUSER /GRILLE TYPE CFM DETAIL NUMBER SHT. WHERE DETAIL IS DRAWN FLAG NOTE COLD WATER HOT WATER HOT WATER CIRCULATING WASTE (BURIED) WASTE (ABOVE GRADE) VENT NATURAL GAS FIRE SERVICE COMPRESSED AIR CONDENSATE RAINLEADER ' t OVERFLOW DRAIN GATE VALVE ; BALL VALVE OR GAS COCK CHECK VALVE UNION . LINED DUCT FLEX DUCT SUPPLY DUCT RETURN OR EXHAUST DUCT VOLUME DAMPER MOTORIZED CONTROL DAMPER r REMOTE OPERATED VOLUME DAMPER i SMOKE DAMPER COIvB I NAT I ON SMOKE /FIRE DAMPER TURNING VANES FIRE DAMPER BACKDRAFT DAMPER FLEX CONNECTION THERMOSTAT, SENSOR MOUNT ® 4'--6" A.F.F. OPPOSED BLADE DAMPER FLOOR CLEANOUT WALL CLEANOUT ABOVE FINISHED FLOOR NOT TO SCALE STAINLESS STEEL GALVANIZED SHEET METAL EXHAUST GRILLE CEILING DIFFUSER VENT THROUGH ROOF ACCESS PANEL SUPPLY AIR RETURN AIR EXHAUST AIR REVISION NO rte ::: She.tt MO.1 e96- ..• r .•i..►+►�.•.....r+•.+...w.,wr.• . i..M. , 1. m R,Y _.� «V+•.fy►. •t , .. -.... a ..,A.. .. . ,�..;• «- - .....•. .... .......�...- .+� «.rl►.::.+v�i.�- ... -r +fir w i. iii � 7i•� A •. v *''li►`.L"r"t ,• - �► !i�F►.;M.i. � . r•.. r ., • - * �.1�/.r+r++..Y..el. •w. ..��., .. 4 y EXHAUST FAN SCHEDULE CONDENSING UNIT SCHEDULE MARK SERVES MFR , TYPE MODEL MODEL TYPE NET �MBH CFM O.A. SP INCH WC WATTS VOLT 'H WT. LBS 3ONES NOTES EF-- I %OMENS ROOM PANASONIC CARRIER FV -20V03 6 CEILING i 190 D. 8.P." 0.100 42 120/1 15 1.5 . 2 EF--2 MENS ROOM PANASONIC VOLT/PH FV- -20VQ3 1 CEILING 5 190 MEETING RM. 0.100 42 120/1 15 1 1.5 2 EF -3 SHOWER ROOM PANASONIC 2 FV -08VQ2 I CEILING I 90 208/3 0.100 , 21 120/1 15 0.7 2 EF-4 KITCHEN PANASONIC FV-30V03 CEILING 290 0.100 I 64 , 120/1 15 .2.0 1 EF -5 STAFF PANASONIC 1 FV -08VQ2 CEILING 90 ' , 0.100 21 120/1 15 0.7 3 EF -6 MENS ROOM PANASONIC l FV -15VQ3 CEILING 150 0.100 40 i 120/1 , 15 1.5 2 EF -7 WOMENS ROOM PANASONIC FV -15V03 CEILING 1 150 0.100 40 _ 120/1 _ 15 _ 1.5 2 BLOWER COIL UNIT SCHEDULE CONDENSING UNIT SCHEDULE MARX SERVED _ , TYPE 1 MAKE MODEL NOMINAL TONS NET �MBH , EXTERNAL O.A. COOLING COIL HEATING MOCP OP. WT. NOTES: FAN MOTOR DATA WEIGHT ACCESSORIES 1 I 2 CARRIER 38ARZ007 -5 6 MFR. 1 YODEL CFM VOLT /PH i D. 8.P." CFM TOTAL MBH SENS. _ STAGES TOTAL MBH WPD EAT BCU-I H P VOLT/PH MSS) 3 4 5 BCU -1 MEETING RM. 25.8 MAGIC AIRE [ 180 BHX3 -2 5400 1.2 , VARIES , 185 140 1 2 SEE DUCT FURNACE I 3.0 208/3 780 X , X X X X D(JCT FURNACE SCHEDULE CONDENSING UNIT SCHEDULE MARK MATCH TO UNIT 1 MAKE MODEL NOMINAL TONS NET �MBH EER ` VOLT PHASE MCA MOCP OP. WT. NOTES: CU--IA i BCU-I CARRIER 38ARZ007 -5 6 69 12.4 VOLT /PH i 208/230 3 25.8 , 35 260 4 CU 80% BCU-I CARRIER 38ARZ007 -5 6 69 12.4 1, 2, 208/230 3 25.8 35 260 4 i _ 1 . D(JCT FURNACE SCHEDULE MARK MAKE . - . MODEL CFM GAS HEATING ELECTRICAL WEIGHT NOTES: • INPUT MBH OUTPUT MBH EFF MIN. PRESS. AMP HP I VOLT /PH i DF -I REZNOR 1 HSC -300 5400 300 240 J 80% 5" W.C. 2.0 NA 1 120 1 300 1, 2, 3, 4, 5, 6 0 INDOOR UNIT SPLIT FURNACE SCHEDULE MARK MAKE MODEL F -2 LENNOX 026Q3 --50 F -3 LENNOX 1 G2603-50 1200 0.5 1/3 F - LENNOX i l G26Q35O 1200 1 0.5 l J3 F -5 LENNOX G2603-50 1200 0. 5 1 1/3 ■ F -6 LENNOX j G26Q3-5O 1200 0.5 NOTES: 1. SWITCHED BY WALL SNITCH 1200 2. SWITCHED WITH LIGHTS WITH 10 MIN. (ADJ.) TIME- -OFF DELAY. 3. PROVIDE 60 MINUTE TIMER BY DIV. 15. NOTES: I. CONCENTRIC TERMINA'' KIT 2. 24 V CONTROL TRANSFORMER 3. CONDENSATE DRAIN FLANGE KIT. 4. 409 STAINLESS STEEL HEAT EXCHANGER. 5. SEPARATED COMBUSTION 6. 2 -STAGE GAS VALVE ACCESSOR 1. PROVIDE TXV ON ALL DX COILS. 2. MIXING BOX WITH MODULATING ECONOMIZER. 3. PROVIDE VARIABLE FREQUENCY DRIVE (VFD). 4. PROVIDE 2" FILTERS 5. PROVIDE 208V-24V PAN RELAY CONTROL PACKAGE. SUPPLY TOTAL _t_ ESP CFM W.C. 0. 5 FAN HP 1/3 OSA CFM I 3 L 150 105 150 180 180 NOTES: I.PROVIDE TXV ON ALL DX COILS 2. SCROLL COMPRESSORS 3. CRANKCASE HEATER 4. ANTI -CYCLE TIMER 5. PROVIDE T7300-2003 SERIES 7-DAY PROGRAMMABLE THERMOSTAT COOLING --DX TOTAL MBH 35.4 1 25.8 35.4 35.4 35.4 35.4 SENSIBLE MBH 25.8 25.8 25.8 25.8 f EAT DB / WB BoLs7 80/67 80/67 80/67 80/67 t ui : �eraru rli r u 1. SCROLL COMPRESSORS 2. CRANKCASE HEATER 3.ANTI-CYCLE TIMER 4 OUTDOOR STAT PROGRAMMABLE 2 STAGE HEATING/COOLING WITH LOCKING DEBONAIR #3305250 --FS OAT DB / WB 85.0 85.0 85.0 85.0 85.0 SEER 1 0 00 id 00 10.00 10.00 10.00 HEATING --GAS ,tr MBH IN 50.0 50.0 50.0 50.0 50.0 MBH OUT OP. WT. EFF. VOLT PH MCA LBS. MARK 47 0.94 120/1_ 12 200 CU-2 47 _ 0.94 120/1 12 200 CU - 47 0.94 , 120/1 12 200 , CU-4 47 0.94 ' 120/1 12 200 CU -5 47 0.94 120/1 12 200 CU - ELECTRICAL OUTDOOR UNIT MAKE LENNOX NOTES: 1. SEE ARCHITECTURAL SPEC 2. PROVIDE ALUMINUM BIRDS 3. PROVIDE MULLIONS, AND 4. NO FLANGE MODEL HS29-036 LENNOX HS29-036 ELECTRICAL VOLT /PH 208/3 208/3 LENNOX ' HS29 --036 208/3 LENNOX HS29 208/3 LENNOX HS29 -036 1 208/3 r r, } MCA MGCP 14 14 14 14 14 20 20 20 20 20 OP. 'WT. LBS. NOTES: 200 I. 2, 3, 4, 5 200 I, 2, 3, 4, 5 200 1 2 3, 4. 5 200 I, 2, 3, 4, 5 200 I, SIvlLDING DKISION DIFFUSER AND GRILLE SCHEDULE ITEM MAKE MODEL 1/2" EGG CRATE, ALUMINIUM WHITE ' HORIZONTAL, STEEL WHITE FRAMES TYP + ' CEILING DIFFUSER TITUS MCD SIDE WALL SUPPLY REGISTER TITUS 300RL RETURN GRILLE TITUS 50F EXHAUST GRILLE WALL GRILLE TITUS TITUS 50F 355 RL DESCRIPTION • SQ. NECK PER PLANS 4 ADJ. MODULAR CORES STEEL WHITE ENAMEL HORIZONTAL DOUBLE DEFFECTION, STEEL, WHITE 1/2" EGG CRATE, ALUMINIUM WHITE ' SIZE 6 "X6" 8 "X8" 10"X 10" 12 "X12" 12 "X6 16 "X6 12 "X12" 12 "X24" 16 "X16" 24 "X24" 8 " -8 n 12 " -12" 36 "X24" MARK CD-1 CD -2 CD -3 CD-4 S -1 S -2 R -1 R -2 R -3 R-4 EA -1 EA -2 WG -1 WG-2 CM OF TUKWUAA • APPROVED APR 16 2004 AS NO all LOUVER SCHEDULE MARK L -2 RUSKIN L--I 1 RUSKIN L -3 RUSKIN L -4 1 RUSKIN MODEL ELF 375 D ELF 375 D ELF 375 D ELF 375 D WIDTH 48 48 42 36 FREE HEIGHT AREA 24 4 72 12 12 1.6 36 1 4. 52 1 MATERIAL STEEL STEEL STEEL STEEL FINISH KYNAR KYNAR KYNAR NOTES: I, 2, 3, 4 I. 2, 3, 4 I, 2, 3, 4 KYNAR [ 2, 3, 4 . FOR FINISH COLOR. CREEN. INSTALLATION HARDWARE AS REQUIRED. MULLION SPACING IS 48" MAX APR 8 2004 z w W m PIV6" )2: W t 1 SA AST RE'1 UD 1EXPWIES 2/16/06 1 o co 47) co � cco (.0 �N� C - N 16 m N U Nco' Z .. N 10 O X • CL y M y... ,. • 4.,0 .., Ere N 18 GAUGE SHEET METAL COVER PIPE CLAMP (TYPICAL) 5/16"X1-1/ 4" FLAT HEAD MACHINE SCREW AND NUT NINET DEGREE ANGLE FITTING. 3/8" X 2 1/2" X 8" PLATE w/ 2 - 3/8 " EXPANSION BOLTS 3" LONG. UNISTRUT PIPE CLAMP (TYP) INSULATION (TYP.) y y • NOTE: RUN STEEL COVER CONTINUOUS FROM CONDENSING UNITS TO RISERS OR PENETRATIONS AT BUILDING WALL. N.T.S. d) Z wQ E }0 • Mir4C .12.-1E.IIII-FE1111=-1- 111=1111 REFRIGERANT SUPPORT DETML N.T.S. • ANGLE IRON UNISTRUT P1026 / GAUGE GALVANIZED SLEEVE 6" LONG. (TYP.) • • INSULATION AROUND SUCTION LINES 1/4 2"X2 "X3 /I6" ANGLE 1 • 1 1 -5/8" GI- 4ANNEL CU -4 ON STAND J " 150 PAD EXTERIOR REFRIGERANT PIPE SUPPORT DETAIL 18 GAUGE GALVANIZED 3I-4EET METAL PROTECTIVE COVER RUN FROM COND. UNIT TO BUILDING. 1 5/8" X 1 5/8" UNISTRUT CHANNEL (GALVANIZED) (TYP.) POST PLATE UNISTRUT P2012A (TYP). ANCHOR TO SLAB. CONCRETE EQUIPMENT PAD 1 i 1 1 i� • STORAGE SEE I /4" SCALE ON M2.2. 1 • ..im.• • lo • 0 111•■••• • • ,•• • . • •• • • ..•,•.••• • • - • ormor +ma loom ` : 2 RELIEF LOWER 48 26XI6RA DD ,� SCALE: 1/8 " -1' -0' 8 " . d=if t ' 1 CD-3 200 TYP OF 2 ( WG I 1- , (CD-3 210 TYP OF 13 COURTYARD 1-BEAM PENETRATION • T7 OF 4 -- 10'4 HANG DUCT TIGHT TO BEAM FLAG NOTES BASEMENT FLOOR - MECHANICAL 18X12 TYP OF 3fr CD -3 260 I 11' U 1 REMOTE DAMPER QUADS IN SHEETROCK CEILINGS. (TYP) 10"• 124 14X12 5A 16X 12 SA 18X12 SA CITY Of APR 16 2004 AS NOIEO WILDING DIOSION • NANO TIGHT TO BEAMS M it4 12Z M2.1 I� 1 REVISED DRAW 1NG 3_4Z --04 BRICKLAYERS AND ALLIED CRAFTWORKERS INTERNATIONAL UNION NEW MEETING HALL AND ADMINISTRATIVE OFFICE BUILDING 15208 52nd avonuo South. Tukwila, Washington MECHANICAL ENLARGED s LOWER LEVEL HVAC PLANS 031401530 .3/Y0 l.8 GIN 03 oaddv GIN :A8 WAY 210 „m /•w>d /! 'TWOS PRoj I NC. 0205 7 _______ 4 x 1s *It' CIVMS ` 1 DePtRES 2 /1s /o6 r 192 Nickerson, Suite #300 S I D E R+ B Y E R S Seattle, Washington 98109 Phone: 206.2852968 , .,t L PiANILAL ENGINEERS, Fax: 206.285.1045 DWI. LAST KEIASED Sheet No. M 2.2 lb 6" DUCT FURNACE VENT ABOVE, 6" CA DUCT BELOW cu -1A 1 REFRICsEFcANt PIPING /SF?R 15ER AREA' 77///// [ cu -1B 1 1" CONDENSATE TO FD L 6 cu -2 1 IGU-4 TRANS STORAGE 36X18 5A tU/ 1" 5L el as I 5 - I 1 00 f 5cu -i I SCALE: 1/4" =1' -0" � cu -3 cu-6 1 32x20 RA DF -I 1 MOP SINK 36X18 5,4 Fl FVATE 'UNIT ON UNISTRUT STAND TO ALLOW PIING TO PA55 BE / LOW. `f — FCTRICAL SERVICE ARFA- O DUC OR EQUIPMENT Rc RvIGE GE AR I 11 PARTIAL STORAGE ROOM PLAN v SEE WALL SECTIO ''J" ON ARCH PLAtit I , 24x20 1i ; DAMPER ifft WOMEN COORDIN ; Tt WALL PENETRATIQN W/ G.C. r I • 1 L-4 1 36 "X36" LOUVER 16"X14" RA. 16"X14" 5.A. 20"X12" R.A. 16"X14" S.A. F.b 1 F-4 1 14 "X14" VFD MOUNT UNIT AT AFF 05A TRANS 16X56 TO 20X40 SECTION 1/4'•1' -0" PROVIDE ACCESS PANEL TO SERVICE MOTORIZED DAMPER 16 " p 1 IR in M2.2 0 L_J F -3 I 16 "X14" S.A. (TYP) SECTION 1 / "• 1' -0" J REFRIGERANT PIPING OEM WIS. 4 CONTROL CONDUIT SEE DETAIL 3/M3.2 8". 0.5.A. TO S". 0.5.A. TO 36"X16" R.A. PLENUM F-2 1 16"X14" RA. REFRIGERANT PIPING IN TRUSS BAYS STEEL CHANNEL W/ 3PRINc - I50LATORS FACTORY MIXING SOX 32X20 RA W/ 1" 51.. 18" DEEP PLENUM 5L 1" W/ INTERNAL PARTITION FOR OSA TO OTHER 13CU' S de , ..- -- LOUVER L -1 12"X48" SLEEVE WALL 1 F -4 f F 1 • 8". 0.5.A. 16 ". 16X14 5A 16X 14 RA F -5 col oval" mva iss's NpiEO orifietos wow COMBUSTION AIR 4 VENT (CONCENTRIC TERMINATION) THROUGH ROOF. TYPICAL FOR ALL FURNACES. 18" HIGH Cs3M FURNACE STAND, 16 GA. WIT- I" 5.L. 3/4" CONDENSATE TO FLOOR DRAIN TYPICAL FOR ALL FURNACES. SEE TRAP DETAIL 4/P3.2. fl1O3-ir 1 .+..+ :.......-- «...:.►ra.. ,. r�iri�.ar+ � ...iiwi�/t r y • 4 �.` uraz • +ru.Y f � r1 nwMr• N a.. �a e M • V\I _ ■ /MIr ■ • � • � • . �r • 0 • 1 . ►� rpas 1 1 I I mut io• Il or i tSE111 1 g • CD -3 250 CD -3 300 CD -3 300 TYP OF 4 EA TYP OF4EA 10 ". 5A TYP OF 4 OFFICE LEASE SPACE 10". 5,4 TYPOF4 �.1 13 9=1 01t4xtQ 5/F DAMPER ATI! FL LEVEL 36X16 RA F -5 I6X14_5A i EF - '1 4 • x� 8" EA • / 1 / fl fcp K I� M OOF DEC I r. 4 1 "e Fe DORMER LOCATED ABOVE DOORWAY. 16 "Q 14X14 aA UP TO ROOF VENT, GREEN DECK GRSR- WITH ROOF CURB. 6 ". EA CD -3 200 • 75 8 M 1 R - r - s% 1 ; 1.088Y 1111 1 U mom C CD-3 225 OPEN_ FFICE -' Ii : FIRST FLOOR - MECHANICAL SCALE: 1 /8'A' -0' • I CID-3 I 300 F-6 F -2 R -2 IQ". FERENCE ROOM CD -2 200 IC TYP OF2 T RISE UP IN TRUSSES 14" WIDE FURNACE BUILDING SECTION 1/8'•'1 -o' • • MEN WOMEN WOMEN HALL STAGE or( OUU APPROVED APR 16 2004 AS NOIED WADING DM ON OPEN OFF e$7*te440 ApR 08 Qpg 0 U) w rwitet N.. `EXPIRES 2/16/06 I 0 0 � o m 0 cc a r n"16 CO mON N �p N CO. . t�... Yl..- `..++v.v.�.•.�.rri.11�s ... r`�t:..1.. .� ` "''..IdT.�.''."la'= }.. - ++r•T.. �v..�w+Y Y •,r .. dir M2.3 LAST 6• MAXIMUM FLEX DUCT. PERF. DIFFUSER PLATE 1 M3.1 MI IN TYPICAL DIFFUSER N.T.S. SHEET METAL PLENUM WI TN I" LINER CEILING T -BAR OR SURFACE MOUNT DIFFUSER FOR GWB CEILING CEILING DIFFUSER OvER SIZE PLENUM 130X FOR 5.L I II XI M XI II s$z METAL ON DIFFUSER IO/'X 10" AND SMALLER NORMALLY CLOSED COMBINATION FIRE /SMOKE DAMPER 115" CLIP (TYPICAL) 1 PIGAL) WELD OR BOLT FIRE DAMPER TO SLEEVE NOTE: L =I /4 W (4" MINIMUM.) MAIN AIR DUCT 3" MIN w NOT ELECTRICAL POWER CONNECTION REQUIRED COORDINATE W/ ELECTRICAL SECTION OF WORK N.T.S. _ N . T. S. 1 3 MIN RATED WALL CONTINUOUS WELDED I6 GA. SLEEVE OPERATOR -- 1 -1/2" x 1 -1/2" x 1/8" ANGLE ALL AROUND. DO NOT SECURE TO WALL. WELD OR BOLT TO SLEEVE. U.L. LISTED COMBINATION FIRE /SMOKE DAMPER •t M3.1 DUCT CONNECTION ACCESS DOOR AIR BRANCH DUCT (TYPICAL) O 24 GA. LOCKING QUADRANT HANDLE OR REMOTE CEILING OPERATOR WHERE DAMPER 15 INACCESSIBLE REMOTE GABLE LINKAGE TO CEILING ADJUSTING QUADRANT CEILING DIFFUSER W/ DIFFUSER PLENUM INSULATION FLEX DUCT SQUARE TO ROUND TAKE -OFF DETAIL Scale: NONE YOUNG REGULATOR, MODEL 5020 CC VOLUME CONTROL DAMPER 22 GA. RIGID SHEET METAL WRAPPED WITH INSULATION INSULATED FLEX DUCT MAX. LENGTH 6' -0,1 SEE SECTION 1 I A (TYP.) 45 TAP 22 GA. BLADE NEOPRENE BUSHING EACH END DAr LAST WAND 0 c A 2 0 2 C • v b CNI GO c CO N J F- W 0 8 o zo s c o CD to ao r o .c m O N tNcD 2 g:2g A CZ z z 4 z Q z 3 . ai NOTE; TYPICAL FOR UPFLOW AND I-IOR I ZONTAL FURNACES. 41 .N.T.S. AIR FLOW TYPICAL FOR ALL RA. GRILLES RETURN AIR GRILLE • 1 SASH LOCK TYP, OF 2 SHEET METAL ELBOW W/ 11 LINER CEILING 7 -BAR OR SURFACE MOUNT RTN. AIR GRILLE OF DOOR I" TRACK TOP AND BOTTOM """-----RETURN CONNECTION DUCT I /8t THICK NEOPRENE GASKET FURNACE HINGE FULL I-1E I GHT � EXTERNAL FILTER SECTION DETAIL M3.1 N.T.S. (MODIFY DOOR FOR HINGED ACCESS) j4OTE: CI ALL COMPONENTS TO BE AS SPECIFIED= NO SUBSTITUTIONS OR Si-10P / FIELD FABRICATED PARTS. IT SIZE DAMPERS A5 INDICATED ON DRAWINGS. DAMPER FRAME TO COMPENSATE FOR DUCT LINER T1-4ICKNE5S. F.A. DUCT W/ LINER r FRESH AIR DAMPER ASSEMBLY DETAIL N.T.S. • DAMPER ACTUATOR MOTORIZED DAMPER HINGED, 51-1A51 -I LOCK ACCESS rx XR (10"x 10") LOCKING QUADRANT MANUAL AIR BALANCE DAMPER SET TO AIR QUANITIE5 ON AIR BALANCE SCHEDULE MARK SETPOINT AFTER AIR BALANCING. M EXPIRES 2/16/06 M3.1 1 .•v•aw...•• y�,.p.. ::J...v.�.' ; A •�- ��.JF.+.•�..�Mw....�.+.w. itii�iM _ w.= f► « .{�0 tiyi4�y' « .. 110 •t• • N•' 2 ei HWS LINE WHERE SHOWN ON SCHEME. SEE SHEET M -4. S.A. DUCT 51UT -OFF VALVE ADJUST BALL VALVE TO PREVENT EXCESSIVE CIRCULATION TNRU FEEDER N.T.S. CIRCUIT BALANCING VALVE (SELECTED FOR RATED FLOW AT MID RANGE OF SCALE) BOLL VALVE (TYP.) O 1 NOTE: REDUCE PIPING AT COIL CONNECTIONS IF NECESSARY X 12" LONG AIR CHAMBER - -HIGH POINT OF MAIN i 3/4" HOT WATER COIL • —14WR ���r 777711L�..LLYY//1 ` WW5 1 1/4" NWS LINE WHERE SHOWN ON SCHEME. SEE SHEET M -4. 1/4" PETCOCK ACCESS CAP (SCREWED) 3/4" 1 i KNEE BRACE SUPPORT MADE OF 2 "X2 "X3 /16 "XI' -O" MITRE JOINT AND WELn. ANCHOR TO WALL WITH TWO $10 X 3" LONG WOOD SCREWS PER ANGLE. PROVIDE 2" x 12" SOLID BLOCKING IN WALL SEE DETAIL A /A -I4. �---- CHEMICAL FEEDER 3/4" DRAIN VALVE WITH MALE HOSE END. CHEMICAL TREATMENT SCHEME • Alb NOV -- MAIN R.A. DUCT EDUCER TYP. err r qwwwwwwwr UNION (TYP.) BALANCE COCK / BALL VALVE STRAINER 1 3 -UJAY ATC VALVE (3 P5I DROP) BCU UNIT H.W. CONNECTION DETAIL N.T.S. I/2 "- EXTEND PIPE TO 6' AFF ALL VALVE 1/2" MALE NOSE END �.., CONNECTION. a MANUAL AIR VENT DETAIL M4.1 N.T.S. 3 WAY CONTROL VALVE, MODULATED BY BOILER CONTROL PANEL. DIAPI -NRAGM TYPE EXPANSION TANK r LOOR RETURN SENSOR FLOW SWITCH SEN SOf - 4 1 GENERAL NOTES: 1. PROVIDE UNION 4 514UT -OFF VALVE AT ALL CONNECTIONS TO EQUIPMENT 2. ALL I- JORIZONTAL PIPING SMALL BE MIN. 6' - O "A.F.F. 3. SEE HVAC PLANS FOR BOILER COMBUSTION AIR AND VENT SYSTEM. 4. PROVIDE MANUAL AIR VENTS AT ALL HIGI-I POINTS OF PIPING SYSTEM. SCALE: N.T.S. BYPASS BALL VALVE 3 / 4 " te r BACKFLOW PREvENTER W/ 1/2" DRAIN TO FLOOR DRAIN d • .4r! 2 � TO BOILER PANEL 0 ---- THERMOMETER I:IT1i b1 CW MAKEUP, SEE " PRV ASSY. SET AT 15 P5I LOOP 9ENSORS°. TYP OF 4 PROVIDE GAS COCK, UNION 4 6" DIRT LEG. (TYP. 2 PLACES) • NOT USED BOILER PIPING .SCHEMATIC O " DRAIN STRAINER - CIRCUIT SETTER 9E7tER ENABLE OR TRIPLE DUTY VALVE "---CHECK VALVE NWP -2 ENABLE 1 03 AUTO AIR VENT ROUTE 1/2" DRAIN TO FLOOR DRAIN. MAXIMUM 18" SECTION BETWEEN BOILER 5 4 R Q PIPE PRESSURE RELIEF VALVE TO FLOOR DRAIN. Q SEE PUMP DETAIL HWR 0-60 P5I GAUGE I:;11;:1lI TRIPLE DUTY VALVE FLAG NOTES: O PROVIDE AT BOTH SIDES OF ALL PUMPS. O PIPING CONTRACTOR SHALL PROVIDE IMMERSION WELL FOR LOOP SENSORS. CHEMICAL FEEDER BOILER CONTROL PANEL 2 "NWS OUTDOOR AIR SENSOR MmmamMiamm■smamms4r>msommi 1 1/4 " 1" 11f? "HWS 1 L REFRIGERANT PIPING (TYP) MANUAL AIR VENT (TYP) Illn•M■MinSIMMIMMIN■m■11:::Prmssmoani SIMMIMIMMIIIMMININI■IN■mnamsmaMM(15smsmsmol 1 3 /4" HW5 4 R 3 /4" HWS 4 R 4-- 1 3 /4" 14W5 4 R 3 S R 3 /4" 1-1W5 4 4 R • ►-1 ►► • T • •-•411* • 4I • • 0-4 ■ ► t • • ►-1 ► ► • • 0.4 ► •• • • Santa • .-4 ► • 41 41 • NW COIL (TYP) TX VALVE (TYP) DX COIL (TYP) (2CKT a7 13CU -1) BCU- I BCU -6 • BCU -3 BCU -4 BCU -2 BCU-5 l o2-i2 "8 I'VTV F 9 AUG1 4 rvEr. NMu 2 N TIN cr W co W LAST REVISED Shoot No. EXPIRES 2/ 16/04 M4.1 1) cr z z W 3 . 111 41 • a�A 1 BRICKLAYERS AND ALLIED CRAFTWORKERS INTERNATIONAL UNION NEW MEETING HALL AND ADMINISTRATIVE OFFICE BUILDING T5208 52nd avenue South, Tukwila, Washington HYDRONIC PIPING DIAGRAMS aarVF -- - — - I 0 0 W • i & 0 ° t W 0 to N • • .• ( r> /,� � �� � c . • 4,„ , t .4 t • `z , 00256 - NAL ` k r IRES 2/16/04 1 I � rti 180 Nickerson, Suite #304 S 1 D E R+ B Y E R S Seattle, Washington 98109 Phone: 206.285.2966 M t . r* A N ' C A L E N G J N E E R S Fax: 206.285.1045 DATE LAST PENNED Shpt Mo. M4.2 1 • • 0 HWS LINE WHERE SHOWN ON SCHEME. SEE 1-4EET M -4. SHUT -OFF VALVE ADJUST BALL VALvE TO PREVENT EXCESSIVE CIRCULATION THRU FEEDER 3/4" HWS LINE WHERE SHOWN ON SCHEME. SEE SHEET M -4. 1/4" PETCOCK ACCESS CAP (SCREWED) 3/4" 1/4" KNEE BRACE SUPPORT MADE ti\ OF 2 "X2 "X3 /16 "XI' -0" MITRE JOINT AND WELD. ANCHOR TO WALL WIN TWO 1110 X 3" LONG WOOD SCREWS PER ANGLE. PROVIDE 2" X 12" SOLID BLOCKING IN WALL SEE DETAIL A /A -14. \---- CI- IEMICAL FEEDER 3/4" DRAIN VALVE WITH MALE N05E END. CHEMICAL TREATMENT SCHEME N.T.S. 3 WAY CONTROL VALVE, MODULATED BY BOILER CONTROL PANEL. DIAPHRAGM TYPE EXPANSION TANK s RETURN SENSOR FLOW SWITCH SEN LOOK r --1 S.A. DUCT CIRCUIT BALANCING VALVE (SELECTED FOR RATED FLOW AT MID RANGE OF SCALE) BALL VALVE (TYP.) 1 N.= REDUCE PIPING AT COIL CONNECTIONS IF NECESSARY 41: N.T.S. GENERAL NOTES: I. PROVIDE UNION 4 SHUT -OFF VALVE AT ALL CONNECTIONS TO EQUIPMENT 2. ALL HORIZONTAL PIPING SHALL BE MIN. 6' - O"A.F.F. 3. SEE NVAC PLANS FOR BOILER COMBUSTION AIR AND VENT SYSTEM. 4. PROVIDE MANUAL AIR VENTS AT ALL W1GH POINTS OF PIPING SYSTEM. • SCALE: N.T.S. —-- HWS BYPASS BALL VALVE 3 LOOP SENSORS 1 I - 1 CW MAKEUP, SEE 3 /4" PRV ASSY. SET AT 15 P5I N N_____2 „ J ,v —CIRCUIT SETTER OR TRIPLE DUTY VALVE r—CHECK VALVE N \----GM] TYP OF 4 PROVIDE GAS COCK, UNION 4 6" DIRT LEG. (TYP. 2 PLACES) BOILER PIPING SCHEMATIC R.A. DUCT UNION (TYP.) BALANCE COCK/ BALL VALVE EDUCER TYP. .111•11111111111. 411111111111=1110 3-WAY ATC VALVE (3 P51 DROP) BCU UNIT H.W. CONNECTION DETAIL BACKFLOW PREVENTER W/ 1/2" DRAIN TO FLOOR DRAIN " DRAIN STRAINER • 4 3 se HWP- I ENABLE HWP - 2 ENABLE "wR 0 -60 P5I GAUGE BOILER CONTROL PANEL I-IWS 4 TRIPLE DUTY VALVE CHEMICAL FEEDER W I■ 3/4". X 12" LONG AIR CHAMBER HIGH POINT OF MAIN , FLAG NOTES: 0 PROVIDE AT BOTH SIDES OF ALL PUMPS. 0 PIPING CONTRACTOR SHALL PROVIDE IMMERSION WELL FOR LOOP SENSORS. ROUTE 1 '2 ° DRAIN TO FLOOR DRAIN. @ NOT USED 0 NOT USED O PIPE PRESSURE RELIEF VALVE TO FLOOR DRAIN. 0 SEE PUMP DETAIL 1/2 "- EXTEND PIPE TO 6' AFF BALL VALVE 1/2" MALE H05E END CONNECT ION. MAIN OUTDOOR AIR SENSOR MANUAL AIR VENT DETAIL N.T.S. CITY OF nA APPROVED DEC -5 A NUftu vi A AUG 1 t 2000 PERMIT *ENTER Mirbew ..YIiYI�'�kr .. .. .sM .. V � K ' 4 i J 1 //\\ 1// 1 \C 0 ' i L. 1 � 1( w , i J I \C 0 ' i p � tt L\, Q a. i J BRICKLAYERS AND AWED CRAFTWORKERS INTERNATIONAL UNION NEW MEETING HALL AND ADMINISTRATIVE OFFICE BUILDING 15208 52nd avenue South, Tukwila, Washington NYDRONIC APING DIAGRAMS \C 0 ' i p � tt 0 0 2 Q Q a. r * .iy xl 1r oozy 4 • 'ONALS G w IRES 2/16/04 180 Nickerson, Suite #304 S I D E R+ B Y E R S Seattle, Washington 98109 Phone: 206.285.2966 ME HANICAL ENG[NEERS Fax: 206.285.1045 DATE LAST MAIO SrtNt NO. M5.1 f� SI O5A 2 RA N.T.S. • OUTSIDE AIR DAMPER 1 " / I 1 I 1 1 1 1 1 1 1 1 1 rS 1 / // 24v / � THERMOSTAT a HOT WATER v4LVE DX COIL DISCHARGE AIR SENSOR Bcu- 2,4,5,6 FAN RELAY /CONTRACTOR 24v CONTROL TRANSFORMER ? 208v, IP-1 BY DIV 16 CU 2,4,5,6 BCU 2,3,4,5,6 CONTROL DIAGRAM CU -IA ENTHAPY SENSOR ECON DAMPER RELIEF DAMPER ECON. CONTROLLER UI/ MIN. SET PT. THERMOSTAT BASYS MODEL 3Z IOIIA N .T.S. / / GENERAL: THE FOLLOWING WORK SHALL BE CONSIDERED TO BE UNDER DIVISION 16: 1 ALL POWER WIRING FROM POWER SOURCE TO EQUIPMENT. 2 CHECKING CURRENT CHARACTERISTICS AND ROTATION OF ALL MOTORS. 3 FURNISHING AND INSTALLING DISCONNECT SWITCHES UNLESS SPECIFICALLY NOTED OTHERWISE. 4 FURNISHING AND INSTALLING ALL STARTERS. THE FOLLOWING WORK SHALL BE CONSIDERED TO BE UNDER DIVISION 15: 1 ALL TEMPERATURE, INTERLOCK, AND EQUIPMENT CONTROL WIRING, CONDUIT, AND APPURTENANCES, HIGH AND LOW VOLTAGE. 2 ALL CONTROL WIRING, LINE OR LOW VOLTAGE, INCLUDING BUT NOT LIMITED TO WIRING THROUGH THE COILS OF THE MAGNETIC STARTERS AND RELAYS, AND THROUGH THE CONTACTS OF THERMOSTATS AND OTHER PILOT DEVICES, EXCEPT WHERE NOTED OTHERWISE. OWNER WILL NOT ENTERTAIN ADDITIONAL COSTS DUE TO LACK OF COORDINATION BETWEEN DIVISION 15 AND DIVISION 16 A. GENERAL EXHAUST EF -1 UNIT SHALL OPERATE WITH OCCUPIED / UNOCCUPIED SCHEDULE FROM BCU -4 THERMOSTAT. PROVIDE FAN MOTOR CONTACTOR. B. EF - . STAFF ROOM EXHAUST FAN SHALL BE OPERATED BY A WALL MOUNTED 60 MINUTE TIMER. TIMER BY DIV. 15. r r FAN SEQUENCE OUTSIDE AIR HOT WATER VALVE DX COIL BCU 1 CONTROL DIAGRAM DISCHARGE AIR TEMP SENSOR VFD BY DIV. 15. DISCONNECT BY DIY 16 208v, 3P1-4 BY DIV 16 120v BY Div. 16 IRN 120v/24v TRANSFORMER BY DIV 15. 9 i BOILER SYSTEM NATURAL GAS BOILER SYSTEM 1. A CENTRAL PANEL SHALL CONTROL THE HYDRONIC HEATING SYSTEM. THE PANEL SHALL CONTROL STAGES OF BOILER FIRING, LOOP TEMPERATURE RESET AND ENABLE PUMPS. TEKMAR 252 -1 PANEL OR APPROVED EQUAL. PROCESSOR SHALL CONTROL LINE VOLTAGE PUMPS THROUGH RELAYS. PANEL SHALL BE U.L. LABELED. PANEL TO OPERATE SYSTEM AS FOLLOWS: 0. 120/60/1 SINGLE PANEL SUPPLY POWER CONNECTION b. SEQUENCE BOILER STAGES AS REQUIRED TO MEET SYSTEM LOAD DEMANDS WITH LEAST NUMBER OF STAGES ON —LINE. c. MODULATE BOILER RETURN WATER MIXING VALVE TO MAINTAIN 140 DEGREE RETURN WATER. d. ENABLE BOILER CIRCULATION PUMP AND MAIN LOOP PUMP. e. RESET MAIN HEATING SUPPLY LOOP TEMPERATURE BASED ON OUTDOOR AIR TEMPERATURE. f. BOILER PUMPS WILL BE KEPT ON LINE FOR . MINUTES AFTER THE BOILER HAS EEEN TAKEN OFF LINE. SYSTEM SHALL HAVE A WARM WEATHER SHUTDOWN FEATURE TO SHUTDOWN BOILER SYSTEM AND MAIN LOOP PUMP WHEN OUTSIDE TEMPERATURE RISES ABOVE AN ADJUSTABLE SETPOINT. I. OUTDOOR AIR TEMPERATURE SENOR SHALL PROVIDE INPUT FOR LOOP RESET. 9. BLOWER COIL UNIT OPERATION GENERAL: SEVEN —DAY PROGRAMMABLE ROOM THERMOSTATS PROVIDE STAGED HEATING, COOLING, VENTILATION, AUTOMATIC CHANGEOVER, FAN CONTROL AND NIGHT SETBACK. THERMOSTATS SHALL BE BASYS SZ 1017A SERIES OR APPROVED EQUAL. . BCU -1 BCU -2 THROUGH —6 r 1. FAN SHALL RUN CONTINUOUSLY DURING OCCUPIED HOURS. 2. OUTSIDE AIR (ECONOMIZER) DAMPER SHALL OPEN TO MINIMUM SETPOINT DURING OCCUPIED HOURS AND CLOSE DURING UNOCCUPIED HOURS. i 3. TWO STAGES OF COOLING SHALL SEQUENCE CONDENSING UNITS. 4. HOT WATER HEATING SIGNAL SHALL PROVIDE MODULATING CONTROL OF HOT WATER VALVE. 5. ECONOMIZER CONTROLS SHALL BE FULLY MODULATING WITH DISCHARGE AIR RESET. CHANGEOVER FROM MECHANICAL COOLING TO ECONOMIZER SHALL BE FULLY AUTOMATIC. ECONOMIZERS SHALL BE INTERGRATED TYPE CAPABLE OF SIMULTANEOUS COMPRESSOR AND ECONOMIZER OPERATION. B. RELIEF AIR DAMPERS SHALL BE FURNISHED WITH DIRECT COUPLED ACTUATORS AND SHALL BE SLAVED TO THE OPERATION OF OUTDOOR AIR DAMPER. DAMPERS ACTUATORS SHALL BE MODULATING TYPE. 7. FAN OPERATION SHALL BE CONTROLLED BY A VFD PROGRAMMED FOR HIGH SPEED IN THE COOLING /ECONOMIZER MODE AND LOW SPEED IN THE HEATING MODE. EXACT RPM SET POINTS SHALL BE SET DURING ,AIR BALANCING. 1. FAN RUNS CONTINUOUSLY DURING OCCUPIED HOURS. 2. MOTORIZED OUTSIDE AIR DAMPERS SHALL BE FURNISHED WITH DIRECT COUPLED ACTUATORS. DAMPER SHALL BE FULL OPEN DURING OCCUPIED HOURS AND CLOSED DURING UNOCCUPIED HOURS. SET MANUALOUTSIDE AIR BALANCING DAMPER FOR MINIMUM CFM LISTED IN EQUIPMENT SCHEDULE. 3. A CALL FOR COOLING SHALL ENABLE THE CONDENSING UNIT. 4. A CALL FOR HEATING SHALL MODULATE THE HOT WATER CONTROL VALVE. RECEIVIO env OF 11 ACWILA AUG 12 1003 PERKY apot„ M 4