Loading...
HomeMy WebLinkAboutPermit M03-159 - SOUTHCENTER MALL - JAMBA JUICEJAMBA JUICE 680 SOUTHCENTER MALL M03 -159 Z • 6 U; 0O N 0 W = J H. LL I-- W, ZO.. W W` 2 p� U H: W WZ F: Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049004 Permit Number: M03-159 Address: 680 SOUTHCENTER MALL TUKW Issue Date: 10/29/2003 Suite No: Permit Expires On: 04/26/2004 Tenant: Name: JAMBA JUICE Address: 680 SOUTHCENTER MALL, TUKWILA WA Owner: Name: JG SOUTHCENTER LTD Address: 25425 CENTER RIDGE RD, CLEVELAND OH Contact Person: Name: LISA MACH Address: 705 SECOND AV, SUITE 710, SEATTLE, WA Contractor: Name: EMERALD AIRE INC. Address: 5108 D STREET NW, AUBURN WA Contractor License No: EMERAAI055BL Permit Center Authorized Signature: Print Name: doc: Mech MECHANICAL PERMIT DESCRIPTION OF WORK: PROVIDING ONE (1) ROOF MOUNTED UNIT AND INTERIOR DUCT FOR NEW JAMBA JUICE SPACE. INCLUDED IN SCOPE OF WORK WILL BE: CONTROLS, CRANE, INSULATION START, TEST, AND BALANCE. Value of Construction: $12,000.00 Fees Collected: $46.50 Type of Fire Protection: SPRINKLERS Uniform Mechnical Code Edition: 1997 A-se -ea. Date: /O ; z 1 —D 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating con ion or the p rm ce of wor . am authorized to sign and obtain this mechanical OS permit. r� l�f o n � (AA Date: C 29 S A )As/ . fro Vtr/�l This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M03 -159 Phone: Phone: 206 624 -6239 Phone: 206 872 -5665 Expiration Date:04 /01/2005 Printed: 10 -29 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049004 Permit Number: M03 -159 Address: 680 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 10/01/2003 Tenant: JAMBA JUICE Issue Date: 10/29/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Conditions PERMIT CONDITIONS 11: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 14: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire M03 -159 Printed: 10 -29 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 16: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) 17: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 18: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 19: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating constr ion or the performance of work. tkit- Date: / (Sl �! 1 �� d Signature: Print Name: doe: Conditions M03 -159 Printed: 10 -29 -2003 z U y o III X Nw w ? . O : w z � O z r- w Lji Dp ON 0 I— w w u. 0 . 2.;z U O 2 H Z Site Address: C Sow ��C,e -}er Y��LiJXi # j . Tenant Name: ZTatm ► autet_ Property Owners Name: Company Name: Company Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: %applications' permit application (3.2003) 3/2003 CITY OF TUKWILA Community Development tf'a'artment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** a t l Coo I li�t.lshty� P�1va Sus i ie (Zoo Los eles ('A Mailing Address: ‘.CONTACT,PERSON.`: Name: Ltsa Mai Mailing Address: 706 2 MVe r Git}e, 710 E -Mail Address: pl'aV1V)IV\g e PWta.. eotvn (Lit ICo>c Cons th Contact Person: ' teqC -}'t (-Fon Contact Person: DarTe,r .TohnS� on E -Mail Address: aht abk6 . Gorr) t.. .. ...c MSIrJ'.^ .".r. >C roN.L:'YJ.1•.Y.• Mailing Address: 23t-i- 5 Awe. S Contact Person: 1 01 1 A (eso E -Mail Address: t^ mtIleseY] wtlG0y6ConstrUC -1 • C-CYT Contractor Registration Number: GJ,LI --CDC. e 14i-I a 0 srritl"\ e dm - arch • C. , Page I -' n � i 1' ?�i� _i Building Perm> = Mechanical Permit N Public .Works Permit Project No . King Co Assessor's Tax No.: Suite Number: A F670 Floor: I of I c.eh .!" �cm- ct: Sow. Her'i'enth a ) / City State Day Telephone: City Fax Number: I~dvvxond S City Day Telephone: Fax Number: New Tenant: ® .... Yes (] ..No 200/ Go 24 —, 234 Qa/oq State Zip ZDCot' &ZS - Oz1 30 vJ /1/4 9 BaZ0 State Zip 42-5V - y! 85 426/774 -4/ Expiration Date: /2-l/0 /03 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD - All plans must be wet stamped by Architect of. Record City Day Telephone: Fax Number: ENGINEER OF RECORD -, All plans must be wet stamped by Engineer of Record City Day Telephone: State Zip eol /210 3 - 3 4 15 7 so /uo3- 5G2.9 State ZO(2 / 34O -2 -55 Fax Number: WO/ 3 40 — 2Z to (o • Valuation of Project (contractor's bid price):. 100 Existing Building Valuation: $ Scope of Work (please provide detailed info ;lion): Tev avY4- lvtnptolevvlev- i- y+struc fi' 514 SA. Fr. e.e'l'd+ eanA- ih e1t.vstitnol matt • - hnetre are no Ipeariv9 walls alAd no se./five Will there be new rack storage? 0 ..Yes ( .. No If "yes ", see Handout No. for requirements. Provide All Building Areas in. Square Footage Below I" Fl . . • • 2 "° 3` Floor Floors thru • Basement Accessory Structure! Attached,Garage • Detached Garage Attached Carport Detached Carport • Covered Deck Uncovered Deck 5'74 Nth ofk N/A N/A NIA N//6 tVA N/A NA N /Pc Addition to Existing Structure O 0 Type .of Construction per UBC.• V (sprinklereol 'TYpe.of Occupancy per. UBC B PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 ....Yes ® ..No If "yes ", explain: u Rek kI 4o . tr ravtt' FIRE PROTECTION/HAZARDOUS MATERIALS: �.. Sprinklers 0..Automatic Fire Alarm El -None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El „Yes If"yes". attach list of materials and storage locations on a separate 8 -1/2 x I I paper indicating quantities and Material Safety Data Sheets. '.appliationatpamit application (34003) 3/2003 Page 2 __......,_.«.....,_.c:. .....:......,...a: :,Lk.Guiio.»c�et..: _4e:�r.;, h..:.:.e.i.w::K(,�,- .._..•14i�.::..., i.+.ts�.,.4. Lis4:.uaii6.a.t4ji*J 4Lau.�.x ,.. ai ... Scope of Work (please provide detailed info =tion): hl0 .4.1c, de,VelOpillev14' n ^. a cfe..i pf cy�3njes - IW»orwetmeeV\* 40 u ,n 7 stYQc t 5 4 s. Reevraufav, t lh e s Sov+hcovrktr Mall Water District N.-Tukwila 0... Water District #I25 0... Water Availability Provided Sewer District ...Tukwila 0... ValVue ❑ .. Renton ❑ ...Seattle ❑...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided 0 ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): Hone, apply, ❑...Civil Plans (Maximum Paper Size— 22" x 34 ") ❑...Technical Information Report (Storm Drainage) ❑...Bond 0.. Insurance p.. Easement(s) Proposed Activities (mark boxes that apply): Mare appJ ❑...Right -of -way Use - Nonprofit for less than 72 hours 0 ...Right -of -way Use - No Disturbance .. .Construction/Excavation/Fill - Right -of -way Non Right -of -way 0 ...Total Cut ❑...Total Fill [..Sanitary Side Sewer 0 ...Cap or Remove Utilities .. .Frontage Improvements 0 ...Traffic Control .. .Backflow Prevention - Fire Protection Irrigation Domestic Water .. .Permanent Water Meter Size... ❑...Temporary Water Meter Size.. p ...Water Only Meter Size 0 ...Sewer Main Extension Public _ 0 ...Water Main Extension Public _ FINANCE INFORMATION Fire Line Size at Property Line N/A 0 ... Water [J ... Sewer Monthly Service Billing to: Name: t4/ Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: tapptiationatpa,mit application (3. :003) JII003 Please refer to. Public Works Bulletin #1 for fees and estimate sheet. cubic yards cubic yards a. ❑ O. ❑ Call before you Dig: 1 -800- 424 -5555 . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line WO# WO# WO# Private Private Number of Public Fire Hydrant(s) MJ6 ...Sewage Treatment Page 3 0 .. Highline .. • Geotechnical Report .. • Maintenance Agreement(s) .. • Right -of -way Use - Profit for less than 72 hours 0 .. Right -of -way Use — Potential Disturbance .. • Work in Flood Zone 0 .. Storm Drainage ❑.. .Deduct Water Meter Size " Day Telephone: City 0 ...Renton ❑...Traffic Impact Analysis ❑...Hold Harmless .. • Grease Interceptor .. • Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding Day Telephone: City State State Zip Zip Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <I00K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ IIP /1,750,000 BTU Heat/Refrig /Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind MECHANICAL, PERMIT .TION = 206=431 - 3670 MECHANICAL CONTRACTOR INFORMATION Company Name: l;wror�ld > v� , Iv,G - Mailing Address: 5105 D. st -rtefi n1u3 Contact Person: Cr'4 iev ' aV1 E -Mail Address: or'i( @, erreraldaire . car Contractor Registration Number: ,r EMEKoP.To s5 8L- Expiration Date: q 4/05 **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 12. Scope of Work (please provide detailed information): pRo..ittin (I) rte Mo.r -ka un it- and Ir*._t'I dot .cor new samba Ihckdect In ovr Re will be: crrni-rolS, ctalne , tnsu 1 A.-h of start , - test , arm balance-. Use: Residential: New Replacement ....0 Commercial: New ....0 Replacement ....E Fuel Type: Electric ►0' Gas ....Er Other: Indicate type of mechanical work being installed and the quantity below: Q+J b∎ rYI City Day Telephone: Fax Number: WA- 98co - 7 State Zip 2e5/ S7Z GTolac 255 /s72 - PERMIT APPLICATION NOTES . - Applicable to a t permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Ltsa M2ck (121/44 . Torte A t.a taies, Ivtc,) Mailing Address: 1O 2rd Ave. , 710 Seatf1 City Print Name: 4pplivaomtpermit application (3-2003) 3/2003 Page 4 Day Telephone: 20('0 /kill./ —((Z39 Wl- 907(7 State Zip Date Application Accepted: /0 -0/ -03 Date Application Expires: Staff Initials: ... a.. _:::.<ii;::;:...._:al.:.,.�.... `- r r:.ti.:i,_:�.r.�;.�z:;�:,11�c.;: Let :u;�:t.3:�.•�tr:,..>k.:iir�.k. Parcel No.: 2623049004 Permit Number: M03 -159 Address: 680 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/01/2003 Applicant: SAMBA JUICE Issue Date: Receipt No.: R03 -01311 Payment Amount: 46.50 Initials: SKS Payment Date: 10/29/2003 09:36 AM User ID: 1165 Balance: $0.00 Payee: EMERALD AIRE INC TRANSACTION LIST: Type Method Description Amount doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payment Check 6378 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT 46.50 Account Code Current Pmts 000/322.100 37.20 000/345.830 9.30 Total: 46.50 4172 10/29 9716 TOTAL 46.50 Printed: 10 -29 -2003 INSPECTION RECORD Retain a copy with permit INSPECTION NO. : ITYOF. TUKWILA BUILDING DIVISION, : Southcenter Blvd., #100, Tukwila, WA 98188 Pr t: i9'►b u1�� ry t4t 1 g ddress :.. 01.0c) Special, nstructions: Type of Iugeoh Date Called: Date Wanted' (- /0 a.m. p.m. I Requester: ,d/V A// � lone No: L/ �a C,0 y -- /�� l proved perapplicable codes. El Corrections required prior to approval. COMMENTS: e � ,c4 IJ Ail)" 2 4 L/ i (Ppi Ja Q S c i . 6614 # //7"P a /z. re ,c Date: _ Re .J /r I z- O REINSPECTION E REQUIRED rior to inspection, fee must be at 1300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. t No.: 'Date: INSPECTION RECORD Retain a copy with permit ::.INSPECTION NO. C I T Y OF:TUKWILA BUILDING DIVISION 300 Southcenter Blvd., #100, Tukwila, WA 98188 ;e , � Add rress ©© : n4ig1/ Special Instructions: Type of Inspection: R7 NIZ Date Called: Date Wanted: — X0 a.m. p.m. Requester: 2h ../ Ph ne N o: � � f / "? _/ 3 / ppr'oved per applicable codes. (206)431 -3670 Corrections required prior to approval. COMMENTS: Z/f.Chs a» -.4-4 dl mot /1 - c p � a- $47.00 REINSPECTI paid at 300 Southc Receipt No.: Date: // — Z-a N FEE REQU}((ED. Prior to inspection, fee must be nter Blvd., S ite 100. Call to schedule reinspection. Date: Proje t: � � ' c/1// Type of Inspection: ,�; �� r - �' 4.44 C A r . � �S c -t ?' Date Calle : // `0.3 Special Instructions: Date Wanted: a.m. // V p.m. Requester: Ph99n�e No: /. -Cn 66* - /oSz INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 specto Rec ' • o.: roved per applicable codes. REQUIRED. r INSPECTION RECORD Retain a copy with permit NO • (20 )431 -3670 Corrections required prior to approval. COMMENTS: r» � E 4 e t YV1 I p--11 S,�[e ,AI s rht.+ Da� -u bet- r ; Date: REINSPECT 16N FEE R for to inspection, fee must be aid t 6300 Southcenter Blvd., � 0. , 1 Call to schedule reinspection. 'Date: . -f1 is".i1i■-+ INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION ' : 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Proje t: :.� . r Pt Lt tN Address: . .0 V Special Instructions: Type of Inspection: 1Z d1 1.1 -i C - A Avv∎ Date Ca e 11 — 1 3 Date Wanted: a.m. 8—o P.m. Requester: _ (� L�C.r.1co IJ er Phone No: .. b (nCY — I t, ■pp•ov per applicable codes. ector: f"Y103 -1 S9 PERM (206)431 -3670 Corrections required prior to approval. COMMENTS: 1 — i n vJ I >J - I--rry Y, l.yC lr" Q cmcs + - ER pv I o.11. Q t .- 19 v� • t ` 1 }��+1� ro �Slos C- ∎ 64v. r S 1 I d oat) 1:t v 1PcsJ tS ? E rf A tLtit+-e c(J.. Date: . _ I REINSPECT k N FEE REO IRED. Prior to inspection, fee must be ald aC t300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.; ..; Date: Pro ct: \A� Type spection (A In • A dress �e S at( Date ailed: I b 2103 Special nstructions: a.m. Date Wanted: I1 ( (:3 )03 Request r: i. °V T Phone No: - 2(76 -LeOLI - I G INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1 )3_ JS9 PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 36713 Approved per applicable codes. COMMENTS: z r a ❑ 547.00 REINSPECTION FE l EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. El Corrections required prior to approval. Receipt No.: Date: Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM Sp' HP /BHP Flow Control ei livervice APPROYED Efficiency 8oA 11-oi Lec.u..)01c... LOA o4-1! ?B cop Itrer, too 74 ova tori oeo (oo IC — 12x,F jO -CT2 2C) AS riu l LD — I'4M ile , Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency 8oA 11-oi Lec.u..)01c... LOA o4-1! ?B cop Itrer, too 74 ova tori oeo (oo IC — 12x,F Project Info Project Address 1 iwc5A I taz- 0,irra cvi,ri m Date 7 r geD j (40 ) 3( _N1Tr -IZ 11 FC676 Brand Name For B Dept. Use CITY UK RECEIVED OF TUK WIIA � ' ' - ` �"Ti 1>-i,uI.A,., WA. 951 tA6 Total CFM Applicant Name: SEER or EER Applicant Address: �} 70S ZrfQ Avg 7 to Sf c 6vtiyp lv4-- Applicant Phone: a ^ 40.24_ 1.0..4.347 LeilmoNic, Equipment Schedules 0• The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER _ 3 IPLV Location V-O( LeilmoNic, LezAo42) 48 E OOa ![aoa (oo IC — 12x,F Mechanical Summary L • • f MECH -SUM 2001 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. A x of ax -tsc N( M62 TeAt1A,+r zpAca ❑ Includes Plans Include documentation requiring S - . 1 0:I _ 1 - ' U.: One ff FILE COPY TIVi8 mM Qam +g igkimPAr 3f tai o?rtr14161 r, nrn Compliance Option Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) 'If available. 2 As tested according to Table 14-1A through 14 -1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Mos- 159 June 2002 - KJM System Description See Section 1421 for full description of Simple System qualifications. , If HeatinglCooling or Cooling Only: K. Constant vol? %Air cooled? K Packaged sys? L - Split system? 0 Economizer included? <54,000 Btuh or 1900 cfm? If Heating Only: Q <5000 cfm? 0 <70% outside air? Mechanical Summary (back) M EC H -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. _1 ..s a: .i : . Heating/Cooling • or Cooling Only Reference Section 1421 No Reference LSection 1420 ..: C. • 0 Use Complex Systems Reference Section 1430 !Complex Systems I Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans 2001 Washington State Nonresidential Energy Code Compliance Forms Checklist MECH -CHK Juno 2002 • KIM Project Address J Ba,, r_\) IC.-- Soon( .. v14&.,1,. Date 7- l7_ '1.,20 t The following Information is necessary to check a mechanical permit application for compliance with the mechanical requirements In the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component 'Information Required Location Building Department on Plans, Notes HVAC REQUIREMENTS (Sections 1401 - 1424) 1411 Equipment performance A C�. 1411.4 Pkg. elec. htg.& ctg. List heat pumps on schedule 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1411.1 Combustion htg. Indicate Intermittent ignition, flue/draft damper & jacket loss 1412 HVAC controls leg 1412.1 Temperature zones s Indicate locations on plans (1e,5 1412.2 Deadband control Indicate 5 degree deadband minimum A. 1412.3 Humidity control Indicate humidistat II as. 1412.4 Automatic setback Indicate thermostat with night setback and 7 duff. day types IliSS 1412.4.1 Dampers Indicate damper location and auto. controls & max, leakage AA 1412.4.2 Optimum Start Indicate optimum start controls .a.. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule MSS 1412.6 Combustion htg. Indicate modulating or staged control 1 lc- » 1412.7 Balancing Indicate balancing features on plans y� 1422 Thermostat interlock Indicate thermostat interlock on plans las 1423 Economizers Equipment schedule 1413 Air economizers laS 1413.1 Air Econo Operation Indicate 100% capability on schedule A,a- 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb /1.4.. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance jr' 4 - • 1413.3 Integrated operation Indicate capability for partial cooling A a , 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 9� 1414.1 Duct sealing Indicate sealing necessary y� 1414.2 Duct insulation Indicate R -value of insulation on duct 4 lS%s 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yeS, 1416.1&2 Drawings & Manuals Indicate requirement for record drawings and operation does. Cle5 1416.3.2 Air Balancing indicate air system balance requirements ,�. 1416.3.3 Hydronic Balancing indicate hydronic system balance requirements VI IA.. 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report A •0.. 1424 Separate air sys. Indicate separate systems on plans Mechanical 4.1- "Summary Form Completed and attached. Equipment schedule with types, inpuVoutput, efficiency, cfm, hp, economizer SERVICE WAl ER HEATING AND HEATED (Sections 1440 - 1454) 1440 Service water htg. 4 � 1441 Elec. water heater Indicate R -10 insulation under tank A.. 1442 Shut -off controls Indicate automatic shut -off H a$ 4 1443 Pipe Insulation Indicate R -value of insulation on piping 4 i g s 4 1452 Heat Pump COP Indicate minimum COP of 4.0 A, Q 4 1452 Heater Efficiency indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control IL A. 1454 Pool covers Indicate vapor retardant cover rt. A. 1454 Pools 90+ degrees Indicate R - 12 pool cover 2001 \ iinaton State Nonresidential Enerav Code Comolien no is circled for any question, provide explanation: irm Z Z W 00 co J H W u- to _ I— W I-- 0 W H U o O- 0 I— LO W II' 0 tJ • Z U= O~ Z Oct 01 03 05:32p Thorpe & Associates 206- 625 -0930 p.1 To: Firm: City /State: Fax No: Ken Nelson City of Tukwila -Dept of Community Development Tukwila, Washington 206/431 -3665 FAX COVER,SHEET Project Name: Jamba Juice Southcenter Mall Project Number: 030764 FILE COPY Description: Date No. Pages Description - '• 7/31/03 9 Structural Calcuila Comments: Lisa Mach Assistant Plazlne.r Operator: Lisa Mach • • . Note: Original is being sent bv :courier: YES" X .Date: October 1, 2003 Time: 5:30 pm C4 l OF TUKWILA kPdMflW NO_ __ OCT 2 !I 7 AS NOV Ken, Please find the attached structural calcula #ons for the Jamba Juice Southcenter project located at 680 Southcenter Mall, submitted to the City of Tukwila today, October 1, 2003. The structural calculations provided at submittal are no longer applicable. The loft area they refer to is no longer a part of the structure. Please use these calculations for the framing design, seismic anchorage and :stability design, and structural plans and details. A hard copy is being couriered to you in the morning' -and shouly your department by 9:15 am. We apologize for ',the mix-up.'.. CITY OF TUKWILA • OC f r! 2003 PERMIT CENTER • We are transmitting • 10 pages, including this cover page If transmission is not complete, please call (206) 624 - 6239 and ask for the operator whose' name appears below. R.W. THORPE & ASSOCIATES, INC. §§ Planning • Landscape •• Environmental '• Economics §§ §RWT /A 705 2nd Ave Ste 710 Seattle, WA 98104, 206 Fix 206 625 -0930, e-mail planning©rwta com§ / .: Oct 01 03 05:32p Thorpe & Associates 206 - 625 -0930 p.2 3,0/01/2003 13 :53 9012633' DAEMS MYERS ARCH''"`: PAGE 02 1 07/31/02_3M 11:12 PAZ 1 20e 440 2206 AIM Q002 Structural Calculations for the: JAMBA JUICE TENANT IMPROVEMENTS WESTFIELD SHOPPING. TOWN Tukwila, WA IPP/R[9 10/30/ 04' 1 July 31, 2003 Submitted To: Deems and Myers Architectural Alliance, Inc. 301 West 5400 South #200 Salt Lake City, UT 84107 Tel: (801 )-263 -3457 Fax: (801 )-263.3529 By: Andersen Bjornstad Kane Jacobs, Inc. Consulting Civil and Structural Engineers 800 Fifth Avenue- Suite 3800 Seattle, WA 98104 -3103 Tel: (206)- 340 -2255 Fax: (206)-340 -2266 ABKT # 03085,00 REC*NED CITY OF TUKWIU _; 2003 PERMIT CENTER Oct 01 03 05:32p Thorpe 01 Associates 206 - 625 -0930 10/01/2003 13:53 8012633x", DAEMS MYERS ARCH ?'`"' t 07/31/00 THV 11:42 FAX 1 200 ILO 2200 ABU INDE TO COMPUTATIONS: p. PAGE 03 2003 EXISTING PRAMING DESIGN, C� ECK: PA GES: n: 2 ' Structural Computations -- -- ------ ---- -- -- Bl -- B3 00 SEISMIC ANCHO AND $�'ABILTY DESIGN: co w w = Jam, St ructural Computations ---------- •------------ .-- - ----- -- LI — LI N o w g 52 d St ructural Details ----- . ------ - ---- -. _-- -...._.-- ..... -.. DI — D3 w z.�. z D; w = o! - O; • z O z STRUCTURAL PLANS ANp DETAIL Oct 01 03 05:32p Thorpe 0, Associates 206 - 625 -0930 10/01/2003 13:53 90126330*Ni DAMS MVERS ARCH,"", 07/31/03 TRU 11 FAx _j 9 340 2200 ABKJ a NMI W4 Ilk Ver s.ta..nrre.W I St.e Beam Design to Mall 1 u,e 'Description Check Existing Steel Beam tar WAG unit Support General Information Steel Section : W1$X40 Center Span 24,00 6 Left Cant. 0.00 ft Right Cant O.00 It Lu ; Unbowed Length 0,00 R Point Loads Dead load 81 1.900 • 6.110 d 1 940 1.9 80 LAN Lead 3.300 3.300 3.300 3.300 Short Term Lucretia,' 8.000 11.500 17.000 22.500 r S4arrlmary End Flay. Span Ur OA�0A 3 1 . 0 00 00 End Fiaiy 1.DF _VOL. Moment 100,061 kkI re : Bending Stress 19.550 kei }biro 0.761 : 1 Shear 15,233 k Iv : Shear Stress 3,120 kse N /Fr 0.217:1 Fares & &tress Summary Ceteeutiens are dietgned 104180 9th Edition ASO and 11137 UDC R.. uiremenbt Pinnad-Pkmed 6m Wt. Added to Loads LL a ST Alt Togsber Tolle : Jambe Juke WwstllNd Shopping Town may: 0.56 Johnston. P.6. Dote: Oseesiptlon ; Framing Design for left Fbor Scope : .g 120.124 k.11 23.760 ksI 70,316 k 14.400 kit •5 y 36.00ks Load Duration Fedor 1.00 Elastic Modulus 29,000.0 kit 0.000 7.000 Y 0 6 1r 7 ft Stalk Lead cue Go a s O Max. Deeedion Length/DL Defl Lengthl(DL+LL Debi e c.. T71eee columns are 0 aed + Liu Lead pieced as noted -e. 01. U. LL +ST U. LL-ST Wain _ q . ,mg r Mar Ca_44. rats Mas. M • 100.09 k-ft 56.69 100,06 k-ft Max. M • kA Mite. Mg Left k•R Mart. M 44 ltigM 141 Sheer Le* 11.70 k 6.42 11.76 k Sheer 44 MOO 15.23 k 7.40 16.23 It Canter Dell, -0.640in •0.391 -0.640 -0.640 0,100 0.000 In Left Cant 0&i 0.000in 0.000 0.000 0.000 0.000 0.000 In Right Cant Dee 0.000 In 0.000 0,000 0.000 0.000 0.000 in ...Query Dell 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reiman e Lett 11,7s 642 11.76 11.70 k RosekortIglett 15.23 7,40 15.23 16.23 It Pa t:.Ie'd per 1.01, K`L/r < Co Jobe 03060.00 -0.640 in 621.4: 1 460.0: 1 i 8ectIon P7opertlss MM. Depth 121.010 in Weigle 40.08 MR r -X1 6.626 01 Width t1.l05U 1•a 519.0014 r-yy 1.565 In Well Thick 0,306 in I -yy 20.90 1114 Rt 1,620 le FlangeThl1sneu 0,506 in 5-et 64.710 Area 11.60 In2 13-yy 8.263 p.4 PAGE 04 004 01/63 Oct 01 03 05:33p Thorpe & Associates 206-825-0930 • 10/01/2003 13:53 0012637' DAEMS MYERS ARCH 07/31/03 TRU 11:43 FAX 1 206 340 2268 p Ste er WON r il Beam Design Description Check Existing Steal Beam for HVAC Link Support Sketch Lch4 Olagrom NISINS•aaiINN 3411 Nnwi • NOVI • •Nra. tM PON • 152N• 1.1 nes: James Juice Westfield Shoppino Town Joh 03068.00 Dow: DA" Johnston. P.R, Oahu Doseription : Rinsing Design for Loh Floor Scope emnOMMIMErar • at yoohNoda 1 • Mori 2 II alo10854maineefenerworleurCNsulations - *co ITT •!' r JJ 1 ;T•1:;:. ; ; 1. 1 I Jo! 1 1r, 0 . r i. 1. b.,. • ..;.; 1. • .64w4 p .5 PAGE 05 0005 SI/ ' ri • *11 . 4 1 4 .....7r ilr; t Oct 01 03 05:33p Thor e & Associates 206 - 625 -0930 p.6 AU/ bi / 2k1 3 13: 53 8012637-1 DAEMS MYERS ARCH', PAGE 06 07/31/02 TIIV 11:44 FAX 11 208 .►10 2208 ABKJ Q1000 v ld t yvAry. ANDERSEN BJORNS1AO KANE IACOBS•INC. Conwtttnd CId1 and %Nowa' Efftdnet. de Aril t. WASHNGTfiN AEKIO.>1>Vj.com PgpJ €CT: T/r> .�JI/ /C'� JcsI 0 � O 9S CV D " A " TE 3/ . . 6J 31 8UEOT: C rI 00.144r Cee/1 -61r' c Peek BY: iD r; OVOICr•_ 88//93 7s-r) s 5oa Taisrt 4•r t R, : 2980/ 97 Mrs w z oo _t_) 1721 ate ago (tom) Z - - 2latra IP 4. J 3-0 p/ e1 £ 3297 41- DE 4.t U9P,�1� 79 �� 11'TJ PeAe c .r -/ 1 Tel. ittpda?T 1,v�, ► +(4 6 *'* Loa - 25 X6) : /s• 1/.33 4 a�a ZPBo A B o s livCo€44m. r") /1f/Fwm fl* /N o al8i'vr z / es f / a o•• " woo _/�� ti S/ 7411f 1? 2 pe .o bve4egots* re.) MA If 14. Ate iE/ 671 •� t 3z_7 //or _i = 27 :4 Zlpo I • wk fie, 77‘ o rr .9i,do 7srE uv. r 0./ao s 0 c7,'UCT7 /15' 4 Ai o7 v7 e aj Z .9 G "Iv meow, o..+ /ry G fr 7, i 't; 7f/are /n► ,�- CGS • NO r / M fOJfic J"e6.4 ♦ r7 r/MT G e rho ro r711E EX/1"P" G' OREN ~le J 1r .7P i.rrt (E) / H5 O w J.r Ate A:246 7 it∎Peor eir 75 • ', AG ( '37- Oct 01 03 05:33p 20/01/2003 13:53 07/31/03 TERI 11:44 • ANDERSEN 8JORN5TAD KANE JACOBS•INC. Cnmvlrin Civil art! Sat/Oval 1PFinens Sunni. WA8++iNufa+ •1010ab4j.corn A summit S'ir FAX 2 206 340 2266 AJlXJ 750 / , at? G .T', fi 34x w (A.rP) J'2p ( 1 % e °a ir* /tf = o. or* ( .e 0..97A. • Z Age >Nl.s : /Y • • Mse T iev i ' 4 pR Idp I.e m Thorpe 04 Associates 206- 625 -0930 801263= DAEMS MYERS ARCH r y„a Amer$ peA $ T D /E'o 0, r 6 g 0 44` �1y7�t�. CAPACer r ` .. 1 0ip. C3 o .i s — 3 � G6. . w (C)(O Rir 6 . 9)(I.33)(10) �Ar Vsvo6, ; 0 . 9 ( ) Boa • 0 6/5. 0 aAT A/47k, d o rt, CRS .ii VSHEETI _ L 1/4./ .r 1/ APe7134 ns5 .t !' c. "wow "no o h fit(- G•t/? Conf•WGn e.4 z;s�•.,� di) 3.0 0.7Sk Zf driewe ..ripe 2. /7k .ch .r t, "040...1 z 4k .1 Li _re a /8 11 A3 41 Sdeci 3 1 11••• , S/0E 62 - rows-) . W PlAt i E, '.7 v i p.7 PAGE 07 i 007 z Wiz d' W 0 0 N 0 CO J I— N LL wO g Q co �. ▪ w. z 1 ._ . O . z U � O N. I- . w S O w O z Oct 01 03 O5:33p Thor�Oe & Associates 206- 625 -0330 p.8 18/01/2003 13:53 8012637 `# DAEMS MYERS ARCH PAGE 0B 07/31/03 TIN 11 :44 FAX 1 200 340 22111.. ABRJ MOO •- ._ Ref- oc,+ rya ►, h WAC WO' ROOF Horner, 7 4a 4,40, of Acv 4 ewr 74o M m4X,Mum Llxq,c 5/x s .c'n+s Ye" -/• ri 4 a � 4 ,C/ 7 /At /E'O oic" , A AS /# C p4,14/ i Z a ? . T i M e /+ ,7L/ GE T E / r i mP, "it m l 'spijcC -G za PAW/ G r c w#, (EJ Cen , L Al A Goo ue4ris X Gi /03 Oct 01 03 05:34p 10/ 01 / 2003 13:53 801263: DAEMS MYERS ARCH ,'''``, 07/01/03 TRU 11:43 FAX 1 He 140 me ABRJ ANDERSEN BJORNSTAD KANE JACO85• INC, Grnn,htng Civil end lwcwul [nginttn Stmt., WASHiNG1lN MKNIMAI•com PAOJECT: OAPIOA •0I Gf SUBJECT: DE 74/1-r 6",42 4 d. 24"O T 40Es (3 8 51 1,7,40 Oat Apia) L Poe P.atry 5.144711W. .s t. o 3enre1,4 y #Ck"• 4 ' ant 7»nruo v1 Thorpe & Associates 206- 625 -0930 vt .SrGi7 o s JOB tr 05 &S 0 6 QATE J 0.71/L fo3 _ .Td /f^Il t►HEiT.t_DZ Mow oiepr Ftege Peh.► d Aim c. t " Ispfroffn4c7utaa CuR.B Fere /?kxc. re) 4 e'4 .rte DEr B Roo, .4rv» JF4C.6", 6 Raw rneca QRAvv,.. G s p.9 PAGE 09 IJ 009 PtraP4E 1441X42 J'I1. TO G win, 3f4 '0 /A 3-p. p. 44E2.0 l Q /Z r Q.0 OR #/ -raj 130 /41..1 y SCAV W1 a /1. 0 0.4 Eltgt A T EACN AA/Q.*. 71a i - LIc 7Y� k VA C OAP r AA/CNNOP /46 6 Ati• SU PF-'o,Q 7 F' /eilm/n/ G, Oct 01 03 05:34p Thorpe b Associates 206- 625 -0930 .0/01/2003 13:53 801263: 1 DAEMS MYERS ARCH,"" x7/31/03 TRU 11:45 FAI 1 206 340 22.11 ABU OKLA r: Ti! ANDERSEN MORNS -AD KANE jACOIIS • INC. consul lnt Gwtl and ssiucaral 6y4M , SEATTLE. WA J UNC VON AMKI..Wri earn ,?U /CE A/4 le: I.•s( ve 7y1 /f. doC/ is o d/ 0 T /V 2, L. r• in/ ~o coAro 4 'p Ir 4, flu 4 Joe w 0 AI Cs WS, o e DATE 3 o Tbv �� 3 •Y: RS, .TWYJV v $mEETM v4,41P3 7 r k VA C (/iv/ r SU,°POA 'AMi, TO &x/ Sr/". fieAA' /N p. 10 PAGE 10 Qi 010 sic • ACTIVITY NUMBER: M03 -159 PROJECT NAME: JAMBA JUICE SITE ADDRESS: 680 SOUTHCENTER MALL DATE: 10 -01 -03 X Original Plan Submittal Response to Incomplete Letter # _ _ Response to Correction Letter # Revision # after /before permit is issued DEPARTMENTS: DG- AUK, 10-43-03 Building Division n Public Works ❑ Complete E 3/ Documents /routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP REVIEWER'S INITIALS: 572 > % / 0 - (a--03 Fire Prevention [n Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -02 -03 Incomplete ❑ PERMIT COORD COPY Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route [/ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 10 -30 -03 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [✓ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • F625-052-001)W97) -DEPARTMENT OF LABOR AND. INDUSTRIES • REG S _AS PROVIDED . BY. LAW :AS' CONS t0119-7 ?._. • .•: 1� �c3::- ",:; :I:iyr;r: :• ,,, =:! .ii• ••. mil° : '�t i�•�s�= x:3251 ; y^: a9l�C:ii::.i - :EMERMiD <AiIZE : TNC , • .5 .Q8'.::D• :.ST'REET: :N -.•.- • : AU8URN; WA; 98 (f0].•' . . • Detach And Display Certificate REGI STERl3:f € fi PQ„U�.DED`'.;BY LAW AS ` (Qbi ECQN't•.tot.G 3E .. . •. � € 7 t i R.:i- =-r.y1;. r11r_' it =i :.. t• ! i2.. I n= 2 -s i=hii: .,i_ 4 � l;Fw R EG-.i- '• # "I;'1. XP. '' jjj��, ` i o-1 iii- ' �' -- E A AAA Q8;,'4` FF l1lif C °' V"'' - G � EMERAI;D i?i�_; . € 5108 D.i { , _ . BURN• VIA -I': = • Signature t ;.: d by DEPARTMPVI.OkABOR AND INDUSTRIES Please Remove And Sign Identification Card Before Placing In Billfold m m MAR 2 8 2003 • E - o m NOTE: SEE EQUIPMENT SCHEDULE FOR DIVISION OF EQUIPMENT ORDER, SUPPLY AND INSTALLATIO N RESPONSIBILITY. IshI 1 6r1L14 LUUlt#MLIV I CONTRACTOR I JAMBA JUICE I OMMER /VEN;::; z � n u_ ► CA ? DC FURNISH I I Fa* INSTALL I 1 _ L FURNISH I I ,INSTALL Nc SAWCUT SLAB FOR (N) IN -FLOOR PLUMBING FIXTURES "§43 REPAIR, LEVEL & SLOPE FOR FINISHES AND TRANSITIONS • • tr © (N) CONCRETE EQUIPMENT CURB • aac; ■ • • X • , o 00 REMOVE (E) INTERIOR WALLS, PARTITIONS AND FINISHES EXTERIOR SIGN (SEPARATE PERMIT) REMOVE (E) FIXTURES, FINISHES AND EQUIPMENT • • MENU BOARDS • • MAPLE BASE IN CUSTOMER AREA z TILE, BASE & GROUT • • •I 1 � 0 INTERIOR GRAPHICS � CERAMIC � FLOORING (N) CUSTOMER AREA FLOG G , V • N I r r •r !• (,) FRAMING • • g U.L. PENETRATION CAULKING AT RATED ASSEMBLIES • I •l -k7") PATCH & REPAIR GYPSUM BOARD AT TENANT SIDE • • • • •. r.•.1 Law (=I a I A FRAMING PLYWD. & GYPSUM BOARD = (E) COIL FAN SYSTEM • • • • F.R.P. / TILE • • a 0 o PAINTING OR STAINING ,. • • ME GYPSUM BOARD CEILING & SOFFIT'S • • Q LAY -IN CEILING WITH SUSPENSION SYSTEM WIRING & CONNECTIONS • • • DOORS, FRAMES AND HARDWARE • I•I •1 PATCH & REPAIR (E) PARTITIONS AS REQ'D. _ • (N) RADIUS SOFFIT AND MENU BOARD SOFFIT THERMOSTATS AND CONTROLS • • • • CONTROL WIRE (LOW VOLT.) •• • PIM WWI 0 • • • • • MUM= . MS 4 • b ♦ • ■ W r • . b • • • • • • o PATCH & REPAIR (EJ EXTERIOR FINISHES TO MATCH E) • • cn ' 0 o 0 EXTEND WATER SERVICE TO SPACE I I . cc IshI 1 6r1L14 LUUlt#MLIV I au. Jr1LL 1 a NJ. I - NJ.J • .. r. w r w • r. r . r r • • V EXTERIOR SIGN (SEPARATE PERMIT) • • MENU BOARDS • • WALL GRAPHICS • • _ INTERIOR GRAPHICS , • • N I r r •r !• • • • • •. r.•.1 . . I A = (E) COIL FAN SYSTEM • • . a WIRING & CONNECTIONS • • DUCTWORK, DAMPERS AND GRILLES • • THERMOSTATS AND CONTROLS • • CONTROL WIRE (LOW VOLT.) 0 411 . . . ' 0 o 0 EXTEND WATER SERVICE TO SPACE • • EXTEND GAS SERVICE TO SPACE • • FINAL CONNECTIONS • , • _ HVAC CONNECTIONS • •, GAS PIPING A/C , • • , WATER HEATER • • • • RESPONSIBILITY SCHEDULE cn MILLWORK STAINLESS v FURNITURE z PLUMBING FIXTURES iEj ELECTRICAL SERVICE TO SPACE (N) ELECTRICAL & TELEPHONE PANELS .. 191 TRANSFORMER. a EQUIPMENT ROUGH -IN AND FINISH LIGHT FIXTURES, MOUNTING ACCESSORIES, & LAMPS MUSIC SYSTEM & SPEAKERS 14.1 EXIT/EMER6EN€Y LILT SEEM ALARM SYSTEM P.O.S. CONDUIT & CABLE PULLS P.O.S. EQUIPMENT INSTALLATION SEE SHEETS A3.1 -A3.3 SEE SHEETS A3.1 -A3.3 SEE SIIE-ETS A3.1 A3.3 SEE SHEETS A3.1-A3.4 • i • • • • ,•• • • g (NJ SPRINKLER SYSTEM HEADS(COORDINATE WITH LANDLORD) . • _• a _� Lora + SPRINKLER SYSTEM DROPS(COORDINATE WITH LANDLORD) _ _ • _ • , ....__ ifo NOTE: CONTRACTOR SHALL SUBMIT (3) SETS OF FIRE SPRINKLER SYSTEM PLANS ff FOR SEPARATE PERMIT. SEE EQUIPMENT SCHEDULE FOR SPRINKLER HEAD SPECIFICATIONS. ABBREVIATIONS ABV ADJ AFF ACT A/C ALT ARCH BLKG BD BLDG CLR CLG CONC COL CMU CON ST DTL DIAM DIM DR DWG DISP (`), EA ABOVE ADJACENT ABOVE FINISHES FLOOR ACOUSTICAL CEILING TILE AIR CONDITIONING ALTERNATE ARCHITECT(URAL) BLOCKING BOARD BUILDING CLEAR CEILING CONCRETE COLUMN CONCRETE MASONRY UNIT CONSTRUCTION DETAIL DIAMETER DIMENSION DOOR DRAWING DISPENSER EXISTING EACH EL, ELEV ELEVATION ELECT ELECTRICAL EQ EQUAL EXT EXTERIOR FF FINISHED FLOOR FT FEET FLR FLOOR FLUOR FLUORESCENT FOF FACE OF FINISH FOS FACE OF STUD FIN FINISH(ED) FRP FIBERGLASS REINFORCED PANEL FO FACE OF GA GAUGE GC GENERAL CONTRACTOR GL GLAZING, GLASS GYP GYPSUM HORIZ HORIZONTAL INT INTERIOR INSUL INSULATION MAX MAXIMUM MECH MECHANICAL MIN MINIMUM MTL METAL (N) NEW NIC NOT IN CONTRACT NTS NOT TO SCALE 0/ OVER O.C. ON CENTER O.S.C.I. OWNER SUPPLIED CONTRACTOR INSTALLED PSI POUNDS PER SQUARE INCH PLAM PLASTIC LAMIN ATE PLYWD PLYWOOD R.C.P. REFLECTED CEI _LNG PLAN SHT SHEET SIM SIMILAR SQ SQUARE SS STAINLESS STEEL TBD TO BE DETERM NED TYP TYPICAL UBC UNIFORM BUILCING CODE UON UNLESS OTHERWISE NOTED UTR UP THROUGH ROOF VtF VERIFY IN FIELD WH WATER HEATER BUILDING INFORMATION ADDRESS: TENANT OCCUPANCY: NUMBER OF STORIES: BUILDING TYPE: APPLICABLE CODES: PROPOSED USE: EXISTING USE: AREA: NUMBER OF EMPLOYEES: CUSTOMER SEATING: OCCUPANCY LOAD: (customer) (kitchen /service /storage) (toilets) (walk -in boxes) EGRESS REQUIREMENTS: TOILETS REQUIRED: TOILETS PROVIDED: • SOUTHCENTER MALL 680 SOUTHCENTER #F670 TUKWILA, WA 98188 B, RESTAURANT 1 TYPE V, SPRINKLERED 1997 UNIFORM BUILDING CODE, WAC 51 -40 1999 NATIONAL ELECTRIC CODE 1997 WASHINGTON STATE ENERGY CODE 1997 UNIFORM FIRE CODE, WAC 51 -44 1997 UNIFORM MECHANICAL CODE 1997 UNIFORM PLUMBING CODE CITY AMMENDMENTS WHERE APPLICABLE RESTAURANT RETAIL 574 SQUARE FEET 2 MAX. NONE 53 sq.ft. /15 =4 290 sq. ft. / 200 = 105 sq. ft. (not occupied) DEFERRED SUBMITTALS 1. FIRE SPRINKLER PLAN - LL FIRE SPRINKLER CONTRACTOR: CROWN FIRE PROTECTION (4 25) 481-7669 2. FIRE ALARM PLAN S,EP,A A 13._,_ REQU �RMIT D MECHANICAL yANICAL �EL �► TNlCA� L UM$ING GAS PIPING CITY OF TU BVIL DING 4 KWjLA ryISI pN 2 1 REQUIRED, 1 PROVIDED 1 (PER UBC SECTION 2902.3, CURFFL 114120.) PUBLIC TOILET ROOMS PROVIDED IN MALL ' "R4,K A spi 111 WOOS* ctVED 1 2Z0 o PROJECT TEAM JAMBA JUICE: AS USED IN THE CONTRACT DOCUMENTS, THE WORD "OWNER" REFERS TO JAMBA JUICE CO, THE LANDLORD'S TENANT, AND DOES NOT IMPLY OWNERSHIP OF THE REAL PROPERTY OR IMPROVEMENTS. ARCHITECT: MECH. /PLUMBING CONSULTANT: ELECTRICAL CONSULTANT: LANDLORD: CONSTRUCTION MANAGER: FILE col 1 that tha Plan Ch;,ck aparcvals are subjedt` o errors and omissions acid approval of planscikes not authorize the viclzt;on of any adoptethcode or ordinance. Receipt of con- tractoriscopy of approved plans acknowledged. • JAMBA JUICE COMPANY 1700 17th STREET SAN FRANCISCO, CA 94103 -5136 ATTN: THEO HARTMAN TEL: (415) 865 -1192 FAX: (415) 865 -1190 DAEMS AND MYERS 301 W. 5400 SOUTH _P00 MURRAY, UTAH 84107 ATTN: RICHARD DAEMS TEL: (801) 263 - 3457 FAX: j801 263- 352§EPARATE PERMIT AND BOULDER ENG, LLC AP PROVAL 811 WEST CEDAR ST � E Q UIRED POCATELLO, ID 83201 ATTN: CLIFF HOLMES TEL: (208) 478 -4613 FAX: (208) 478 -4617 BOULDER ENG, LLC 811 WEST CEDAR ST. POCATELLO, ID 83201 ATTN: CLIFF HOLMES TEL: (208) 478 -4613 FAX: (208) 478 -4617 WESTFIELD SHOPPINGTOWN SOUTHCENTER 11601 WILSHIRE BLVD., SUITE 1200 LOS ANGELES, CA 90025 ATTN: JOSE HERNANDEZ TEL: (3 5 75 -5918 S EPARATE FAX: (310 478 4468 pERMIT AND APPROVAL JAMBA JUICE COMPAN UIRED 1700 17th STREET Q SAN FRANCISCO, CA 94103 ATTN: JIM GRIFFITH TEL: (415)-865-1120 FAX: (415)-865-1190 VICINITY MAP • DRAWING INDEX ARCHITECTURAL A0.1 COVER SHEET A0.2 A1.1 A1.2 A2.1 A3.1 A3.1.1 A3.1.2 A3.1.3 A3.2 A3.3 A4.1 A5.1 A7.1 A8.1 A9.1 A9.2 A9.3 A9.4 GENERAL NOTES /REQUIREMENTS DEMOLITION PLAN SLAB & FRAMING PLAN COUNTER PLAN EQUIPMENT PLAN T- STATION PLAN JUICE COUNTER PLAN EZBAR WALL EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE REFLECTED CEILING PLAN FINISH PLAN EXTERIOR ELEVATIONS INTERIOR ELEVATIONS DETAILS DETAILS DETAILS DETAILS PLUMBING P1.0 PLUMBING WASTE & VENT ''_AN & SCHEDULE P1.1 PLUMBING SUPPLY PLAN P2.0 PLUMBING DETAILS P3.0 PLUMBING NOTES AND SP .CIFICATIONS P .0 PIPING RISER DIAGRAMS MECHANICAL M1.0 MECHANICAL PLAN M2.0 HVAC DETAILS/ SPECIFICATIONS ELECTRICAL E1.0 POWER AND SYSTEM PLAN E1.1 ENLARGED POWER PLAN E2.0 LIGHTING PLAN E3.1 ELECTRICAL DETAILS E3.2 ELECTRICAL PANEL SCHEDULES E3.3 ELECTRICAL SCHEMATICS E4.0 ELECTRICAL SPECIFICATIONS N.T.S. North 413 jamba • • Hulce STORE #561 SUTHENTER MALL 6Soutb�nter #F670 Tukwila WA 9161 Consultant DAEMS & MYERS ARCHITECTURAL ALLIANCE, INC. 301 WEST 5400 SOUTH #200 SALT LAKE CITY, UTAH 84107 PH: (801) 263 -3457 / FAX: (801) 263 -3529 Consultant Registration Issues and Revisions No. Date Issues 1 7/18/03 CONSTRUCTION -- RD 2 8/20/03 HEALTH DEPT. COMMENTS/ STRUCT. -- RD 3 9/30/03 OWNER/ LANDLORD COMMENTS -- RD Project Name JAMBA 5.0 PROTOTYPE Project Number JJ50 Description TITLE SHEET Computer File A01-- SCM.DWG Scale AS NOTED Template 5.0 (1001,/02) A01 0 1 2 003 Pwrr I Registration tt Gi �Itko . lc 41ATF WASHIWlsT(» All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of Daems & Myers Architectural Alliance, Inc, and were created, evolved, and developed kit use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation fur an/purpose whatsoever without the written permission of DMAA ; j07 By Check MO3•01v1.5 • 0 • Imemsminn GENERAL NOTES 1. THE CONTRACTOR IS HEREBY SPECIFICALLY DIRECTED, AS A CONDITION OF THE CONTRACT, TO ACQUAINT HIMSELF WITH THE ARTICLES CONTAINED IN THE GENERAL NOTES, AND TO NOTIFY AND APPRISE ALL SUBCONTRACTORS AND ALL OTHER PARTIES OF THE CONTRACT OF, AND BIND THEM TO ITS CONDITIONS. 2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION LOCATIONS, DIMENSIONS AND TYPES. DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY ARCHITECT FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. CONSTRUCTION PLAN BY ARCHITECT SUPERSEDES OTHER PLANS. 3. THE CONTRACTOR SHALL REVIEW DOCUMENTS AND VERIFY DIMENSIONS AND FIELD CONDITIONS. ANY CONFLICTS, OMISSIONS OR DISCREPANCIES SHALL BE REPORTED IN WRITING THREE (3) BUSINESS DAYS BEFORE RETURN OF BID. THE GENERAL CONTRACTOR WARRANTS, BY TENDERING HIS BID, THAT WORK IS BUILDABLE AS SHOWN. 4. DRAWINGS OF BASE BUILDING CONDITIONS ARE GENERATED FROM AS -BUILT DRAWINGS AND ON LIMITED FIELD OBSERVATION BY THE ARCHITECT. ACTUAL CONDITIONS MAY DIFFER FROM THOSE SHOWN. 5. THE CONTRACTOR SHALL FILE, OBTAIN AND PAY FEES FOR BUILDING DEPARTMENT AND ALL OTHER AGENCY APPROVALS AND PERMITS, CONTROLLED INSPECTIONS, AND FINAL WRITE -OFFS FOR PROJECT COMPLETION. COPIES OF TRANSACTIONS ARE TO BE FORWARDED TO THE PROJECT MANAGER AND BUILDING MANAGEMENT PRIOR TO COMMENCING WORK. 6. THE CONTRACTOR SHALL ARRANGE FOR ALL INSPECTIONS NECESSARY TO OBTAIN CERTIFICATE OF OCCUPANCY. 7. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT, EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS AND LANDLORD REQUIREMENTS. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION AND /OR MISALIGNMENT IN ACCORDANCE WITH APPLICABLE CODES, STANDARDS AND GOOD PRACTICE. 9. WORK AND /OR CONSTRUCTION OPERATIONS SHALL NOT UNDERMINE THE STRUCTURAL ;NTEGRITY OF THE BUILDING. 10. THE CONTRACTOR SHALL VERIFY THAT DRAWINGS ARE THE LATEST ISSUE PRIOR TO COMMENCING CONSTRUCTION. 11. THE CONTRACTOR SHALL, IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS, APPLY, INSTALL, CONNECT, ERECT, CLEAN AND /OR CONDITION MANUFACTURED ARTICLES, MATERIALS AND /OR EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS. IN CASE OF CONFLICT BETWEEN MANUFACTURER'S INSTRUCTIONS AND THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE PROJECT MANAGER AND THE ARCHITECT BEFORE PROCEEDING. 12. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OUTSIDE VENDORS INCLUDING BUT NOT LIMITED TO, TELEPHONE, DATA, "OWNER'S FORCES" ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING AND PATCHING REQUIRED TO RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. 13. ALL COMBUSTIBLE MATERIALS SHALL MEET APPLICABLE CODES. WOOD SHALL BE FIRE RETARDANT TREATED WHERE REQUIRED BY LOCAL BUILDING CODES. 14. THE CONTRACTOR SHALL PROVIDE BACK FLOW DEVICES AS REQUIRED BY LOCAL, STATE & FEDERAL CODES. 15. THE CONTRACTOR SHALL LEAVE A COPY OF REDLINED DRAWINGS AT THE STORE UPON COMPLETION OF WORK. DRAWINGS SHALL BE PLACED IN A 36" LONG 4" PVC WITH A CAP. PVC PIPE SHALL BE ATTACHED TO WALL. AT LOCATION SHOWN ON PLAN. t GENERAL NOTES (coNT.) WORK QOVERep BY IONTRACT QO VMEN'LS 1. WORK NOT PARTICULARLY DETAILED, NOTED OR SPECIFIED, SHALL BE THE SAME AS SIMILAR PAR IS THAT ARE DETAILED, NOTED OR SPECIFIED. 2. IN THE EVENT OF INCONSISTENCIES AMONG THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL INTERPRET THEM WHEN ASKED TO DO SO BY THE OWNER OR CONTRACTOR. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE RESULTS OF SUCH INTERPRETATIONS MADE BY OTHERS. 3. THE GENERAL CHARACTER OF DETAIL WORK IS SHOWN ON THE CONTRACT DOCUMENTS. SUBSEQUENT CLARIFICATIONS MAY BE MADE BY ADDITIONAL LAYOUTS OR LARGE SCALE OR FULL SIZE DETAILS. 4. DRAWINGS AND DIAGRAMS FOR MECHANICAL AND ELECTRICAL WORK SHALL BE CONSIDERED AS DIAGRAMMATIC ONLY, NOT TO BE USED FOR ANY STRUCTURAL GUIDANCE OR PHYSICAL LAYOUT. IN CASE OF CONFLICT, UNLESS OTHERWISE NOTED, 1HE ARCHITECT'S DRAWINGS SHOWING LOCATIONS FOR MECHANICAL AND ELECTRICAL ITEMS AND ACCESSORIES SHALL TAKE PRECEDENCE. 5. UNLESS OTHERWISE NOTED, IT IS THE INTENTION OF THE DRAWINGS AND SPECIFICATIONS FOR ALL WORK, EQUIPMENT, CASEWORK, MECHANICAL, ELECTRICAL AND SIMILAR DEVICES OF WHATEVER NATURE, BE COMPLETELY INSTALLED, HOOKED -UP, MADE OPERATIONAL AND FUNCTIONAL FOR THE PURPOSE INTENDED, AND THAT ALL COSTS FOR THIS BE INCLUDED IN THE CONTRACTOR'S PROPOSAL. 6. ALL ROOFING WORK SHALL BE PERFORMED AND ALL PENETRATIONS THROUGH THE ROOFING MEMBRANE SHALL BE PATCHED OR FLASHED BY THE LANDLORD'S ROOFER, CASCADE ROOFING (206) 464 -0441. THE COST FOR THIS WORK SHALL BE IN THIS CONTRACT. COORDINATE WITH LANDLORD'S ROOFER AND NOTIFY 48 HOURS IN ADVANCE OF WORK. OWNER FURNISHED PRODUCTS 1. PRODUCTS TO BE FURNISHED AND PAID FOR BY THE OWNER AND INSTALLED BY THE CONTRACTOR ARE INDICATED AS "OWNER SUPPLIED" IN THE EQUIPMENT SCHEDULE 2 . OWNER'S RESPONSIBILITIES FOR OWNER FURNISHE ) PRODUCTS: SUPPLY CONTRACTOR WITH PRODUCT LITERATURE, OWNER REVIEWED. PRODUCT DATA AND SAMPLES. PAY FOR PRODUCT DELIVERY TO SITE. REVIEW DAMAGED PRODUCTS WITH CONTRACTOR PROMPTLY. SUBMIT CLAIMS FOR TRANSPORTATION'S DAMAGE. REPLACE DAMAGED, DEFECTIVE OR DEFICIENT ITEMS. ARRANGE FOR MANUFACTURER'S WARRANTIES, INSPECTIONS AND SERVICE. 3 . CONTRACTOR'S RESPONSIBILITIES FOR OWNER FURNISHED PRODUCTS REVIEW SHOP DRAWINGS, PRODUCT DATA AND SAMPLE TO ADEQUATELY ACQUAINT HIMSELF WITH THE SCOPE OF WORK. REVIEW THE ORDER, SCHEDULE DELIVERY, RECEIVE, UNLOAD AND STORE PRODUCTS AT SITE; INSF'ECT FOR COMPLETENESS OR DAMAGE. IF ITEMS ARE DAMAGED, GENERAL CONTRACTOR TO NOTIFY PROJECT MANAGER AND OWNER. INSTALL AND FINISH PRODUCTS. REPLACE AN t' ITEMS DAMAGED AFTER RECEIPT. CONTRACTOR USE OF PRE AI E$ 1. CONSTRUCTION OPERATIONS: LIMITED TO AREAS NOTED ON DRAWINGS. 2. TIME RESTRICTIONS FOR PERFORMING WORK: VER FY WITH LANDLORD. 3. CONSTRUCTION WORK MAY BE SCHEDULED TO BE PERFORMED DURING NORMAL BUSINESS HOURS OVLY (UPON APPROVAL OF THE LANDLORD). 4. UTILITY OUTAGES AND SHUTDOWN SHALL BE COORDINATED WITH LANDLORD. GENERAL NOTES ccoNr> 5. AT ALL TIMES CONDUCT OPERATIONS TO INSURE THE LEAST INCONVENIENCE TO THE GENERAL PUBLIC COMPLY WITH APPLICABLE CODES AND ORDINANCES FOR SAFETY. 6. ASSUME FULL RESPONSIBILITY FOR THE PROTECTION AND SAFEKEEPING OF PRODUCTS STORED ON THE SITE UNDER THIS CONTRACT. 7. PERFORM DEMOLITION WORK AND SUCH SPRINKLER WORK, CONCRETE SAW CUTTING, PAINTING AND SIMILAR WORK CAUSING EXCESSIVE NOISE, DUST OR ODORS DISTURBING BUILDING OCCUPANTS, OR ANY WORK DISRUPTING TENANTS OR PUBLIC TRAFFIC WITHIN THE BUILDING, AFTER HOURS OR AT TIMES AND IN SUCH A MANNER AS OTHERWISE APPROVED BY LANDLORD. 8. COORDINATE USE OF PREMISES FOR WORK WITH THE LANDLORD. 9. LIMIT USE OF SITE FOR WORK AND STORAGE TO AREAS DESIGNATED UNLESS SPECIFIC ADDITIONAL AREAS ARE ALLOWED IN WRITING BY THE LANDLORD. STANDARDS AND CODES 1. GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK. IF THE CONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT VARIANCE THEREWITH, PROMPTLY NOTIFY THE PROJECT MANAGER AND ARCHITECT NECESSARY CHANGES SHALL BE MADE IN ACCORDANCE WITH THE GENERAL CONDITIONS. 2. IF THE CONTRACTOR KNOWINGLY PERFORMS ANY WORK WHICH IS CONTRARY TO SUCH LAWS, ORDINANCES, CODES, RULES AND REGULATIONS, HE SHALL PROMPTLY MAKE ALL CHANGES AS REQUIRED TO COMPLY THEREWITH AND BEAR ALL COSTS ARISING THEREFROM. 3. CONFLICTS: IN CASE OF CONFLICTS IN THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION, THE MOST RESTRICTIVE REQUIREMENTS SHALL GOVERN 4. WHERE CODES OR REGULATIONS, OTHER THAN THOSE LISTED IN THIS SECTION, ARE REFERRED TO IN VARIOUS SECTIONS OF THE SPECIFICATIONS. IT SHALL BE UNDERSTOOD THAT THEY APPLY TO THIS WORK AS FULLY AS IF CITED HEREIN. PARTITION NOTES 1. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF FINISHES INCLUDING CERAMIC TILE, VCT, ETC. 2. DIMENSIONS MARKED "CLEAR" ARE TO BE WITHIN 1/8" ALONG FULL HEIGHT AND FULL WIDTH OF WALLS. DIMENSIONS ARE AS FOLLOWS, UNLESS NOTED OTHERWISE: -- TO FINISHED FACE OF GYPSUM BOARD -- TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS -- TO TOP OF FINISHED FLOORS - TO BOTTOM OF FINISHED CEILINGS -- TO INSIDE FACE OF FINISHED MILLWORK 3. DIMENSIONS SHOWN AS V.I.F. SHALL BE VERIFIED BY THE CON1RACTOR IN THE FIELD BY LAYING OUT THE PARTITIONS. CONTRACTOR SHALL NOTIFY CONSTRUCTION MANAGER AND ARCHITECT OF ANY DISCREPANCY IN IN DIMENSIONS PRIOR TO PROCEEDING WITH THE WORK IN THAT AREA 4. NEW GYPSUM HOARD CONSTRUC LION ADJOINING EXISTING CONSTRUCTION IN THE SAME PLANE SHALL BE FLUSH WITH NO VISIBLE JOINTS, UNLESS OTHERWISE NOTED. 5. FOR BUILT IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20' -0" NON- CUMULATIVE. NOTIFY ARCHITECT IF THIS TOLERANCE IS EXCEEDED. • FINISH NOTES I. ENSURE THAT SURFACE TO RECEIVE FINISHES ARE CLEAN, TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL SATISFACTORY CONDITIONS HAVE BEEN CORRECTED. COMMENCEMENT OF WORK SHALL INDICATE INSTALLER'S ACCEPTANCE OF SUBSTRATE. 2. REPAIR AND PREPARE EXISTING SURFACES SCHEDULED TO REMAIN AS NECESSARY FOR APPLICATION OF NEW FINISHES. 3. CONTRACTOR TO INSURE DELIVERY AND INSTALLATION OF CASEWORK AND FINISH CARPENTRY WILL NOT BE DAMAGED BY OTHER CONSTRUCTION WORK. 4. ALL CODE- REQUIRED LABELS SUCH AS "UL ", FACTORY MUTUAL OR ANY EQUIPMENT IDENTIFICATION, PERFORMANCE RATING, NAME OR NOMENCLATURE PLATES SHALL REMAIN READABLE AND NOT PAINTED. 5. THE CONTRACTOR SHALL PATCH SURFACES TO MATCH ADJACENT IN A MANNER SUITABLE TO RECEIVE FINISHES. 6. COORDINATE WITH OWNER'S DESIGNATED REPRESENTATIVE FOR DELIVERY AND PLACEMENT OF ALL FURNITURE AND WALL -HUNG EQUIPMENT. 7. REFER TO FINISH SCHEDULE ON SHEET A5.1 FOR SPECIFIED FINISHES. 8. REFER TO INT. ELEVATIONS FOR MOUNTING HEIGHTS. 9. WHERE PERMITTED BY HEALTH AUTHORITIES, EXPOSED PIPES SHALL BE COPPER, UNPAINTED. RCP NOTES 1. 2. REFER TO MECHANICAL, ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR DESIGN OF THESE SYSTEMS (DUCT SIZES, CIRCUITING, ETC.) LOCATIONS OF FIXTURES, REGISTERS, SWITCHES, ETC. SHALL BE AS SHOWN ON THE ARCHITECTURAL PLANS AND DETAILS. NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO COMMENCING CONSTRUCTION. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, STRUCTURAL ELEMENTS AND OTHER APPLICABLE ITEMS. NOTIFY PROJECT MANAGER OF INADEQUATE CLEARANCES FOR CEILING LAYOUT. 3. ALL REGISTERS, SPRINKLER HEADS AND LIGHTING FIXTURES SHALL OCCUR WITHIN GRID LINES, INCANDESCENT FIXTURES OR OTHER CEILING ELEMENTS SHALL BE LOCATED AT THE CENTER OF ACOUSTICAL TILES UNLESS OTHERWISE NOTED. 4. ALL LIGHTS MUST BE SUSPENDED INDEPENDENT OF CEILING GRID SYSTEM. 5. REFER TO A4.1 FOR CEILING LAYOUT. HEALTH NOTES STRUCTURAL: -FULLY ENCLOSED BUILDING. - VERMIN PROOF. WALLS & CEILINGS: -LIGHT IN COLOR FOOD PREPARATION, UTENSIL WASH, & WALK -IN REFRIGERATION. (NOTE: LIGHT COLORED MEANS HAVING A LIGHT REFLECTANCE VALUE (LRV) OF 70% OR GREATER. LIGHTING: - SUFFICIENT NATURAL OR ARTIFICIAL LIGHTING, I.E. 20 FOOT CANDLES 30" ABOVE THE FLOOR. -LIGHT FIXTURES SHALL BE SHATTERPROOF OR W/ SHATTERPROOF SHIELDS, AND EASILY CLEANABLE. UTENSILS & EQUIPMENT: -ALL EQUIPMENT MEETS OR IS EQUIVALENT TO, APPLICABLE SANITATION STANDARDS. -ALL CRACKS & CREVICES AT JOINTS SEALED W/ AN APPROVED MATERIAL. - COUNTERS /CABINETS OF ACCEPTABLE QUALITY. • ACCESSIBILITY NOTES 1. NOTE: FOLLOWING ARE ADA GUIDELINES AND FOR GENERAL CONTRACTOR INFORMATION ONLY. LISTED ITEMS DO NOT REPLACE OR AMEND FEDERAL, STATE OR LOCAL CODES. IN CASE OF CONFLICT IN THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION, THE MOST RESTRICTIVE REQUIREMENTS SHALL GOVERN. 2. ALL EXTERIOR DOORS SHALL HAVE A 24" CLEAR HORIZONTAL OPEN SURFACE /AREA AT THE STRIKE SIDE /PULLSIDE OF DOORS. ALL INTERIOR DOORS SHALL HAVE 18" CLEAR AT THE STRIKE SIDE /PULLSIDE OF DOORS PROVIDE 12" CLEAR HORIZONTAL CLEAR SURFACE ON THE PUSH SIDE /STRIKE OF ALL DOORS. 3. ALL EMERGENCY EXITING ALARM AND SIGNAGE TO COMPLY WITH FEDERAL, STATE AND MUNICIPAL CODES FOR ACCESSIBILITY. 4. GENERAL CONTRACTOR SHALL ALLOW FOR APPLIED FINISH DIMENSIONS IN ADDITION TO STANDARD CONSTRUCTION TOLERANCES IN ACHIEVING ALL ACCESSIBILITY CLEARANCES PER DRAWINGS AND /OR ADA GUIDELINES 5. REFER TO INTERIOR ELEVATION SHEETS AND DETAIL #9/A9.2 FOR MOUNTING HEIGHTS. 6. EMERGENCY WARNING SYSTEMS SHALL COMPLY WITH ADA REQUIREMENTS FOR THE HEARING IMPAIRED. VISUAL WARNING STROBE LIGHTS TO BE DESIGNED TO HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE 7. WATER CLOSET & URINAL FLUSH VALVE CONTROLS, AND FAUCET AND OPERATING MECHANISM CONTROLS, SHALL BE OPERABLE WITH ONE HAND, SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST AND SHALL BE MOUNTED NO MORE THAN 44" ABOVE THE FLOOR. 8. THE FORCE REQUIRED TO ACTIVATE WATER CLOSET AND URINAL FLUSH VALVE CONTROLS, AND FAUCET AND OPERATING MECHANISM CONTROLS, SHALL BE NO GREATER THAN 5 LBF. 9. SELF - CLOSING FAUCET CONTROL VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 10. ALL DOOR HARDWARE TO BE LEVER ACTUATED, HARDWARE REQUIRING GRIPPING ARE NOT PERMITTED. 11. ALLEXTERIOR DOOR CLOSERS SHALL PROVIDE 8 )# MAX. PULL. ALL INTERIOR DOORS SHALL PROVIDE 5# MAX. PULL. 12. ALL ELECTRICAL CONVENIENCE OUTLETS AND SWITCHES TO BE LOCATED NOT LESS THAN 15" A.F.F. AND NOT MORE THAN 44" A.F.F. HAZARDOUS MATERIALS ASBESTOS AND HAZARDOUS WASTE EXCLUSION: 1. THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, (AND IS UNABLE TO REASONABLE OBTAIN SUCH INSURANCE) FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF OR THE FAILURE TO PERFORM PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED TO, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND RELATED TO THE INVESTIGATION DETECTION. FIRE CODE NOTE 1. A SEPARATE PERMIT IS REQUIRED PRIOR TO ANY INSTALLATION OF FIRE PROTECTION SYSTEM OR COMPONENT. SUBMIT (3) SETS OF AUTOMATIC FIRE EXTINGUISHING SYSTEM SHOP DRAWINGS AND SPECIFICATIONS TO THE PERTAINING DEVELOPEMENT SERVICES CENTER. 2. THE INSPECTION, HYDROSTATIC TEST, AND FLUSHING OF THE AFES SHALL BE WITNESSED BY THE BUILDING INSPECTOR SPECIALIST (FIRE) NO PIPING SHALL BE COVERED OR HIDDEN FROM VIEW UNTIL AN INSPECTION HAS BEEN COMPLETED. At LOW 48 HRS. FOR SCHEDULING AN APPOINTMENT. 3. PORTABLE FIRE EXTINGUISHERS SHALL BE IN ACCORDANCE WITH U.F.C. STANDARD 10 -1. DEFINITIONS 1. "FURNISH ": THE TERM "FURNISH MEANS SUPPLY AND DELI\ ER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. 2. "INSTALL ": THE TERM "INSTALL" DESCRIBES OPERATIONS A i 1HE PROJECT SITE INCLUDING THE ACTUAL UNLOADING, UNPACKING, ASSEMBLY, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS. 3. "PROVIDE ": THE TERM "PROVIDE" MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. • CITY OF TLIKWU A'PRO'Yt D lO C T 2 4 2GD3 1 L[� STORE #000 StUTH�NTER MALL 6&PSouthcentcr #F670 Tukwila, WA 98188 Consultant No. jamba juice DAEMS & MYERS ARCHITECTURAL ALLIANCE, INC. 301 WEST 5400 SOUTH 1200 SALT LAKE CITY, UTAH 84107 PH: (801) 263 -3457 / FAX: (801) 263 -3529 Consultant Registration Issues and Revisions 1 7/18/03 Date Issues Project Name JAMBA 5.0 PROTOTYPE Project Number JJ50 Description SPECIFICATIONS Computer File A02 SCM.DWG Sr dlt' AS NOTED Templ1ttt' : ► U ( /" ii /61) A0.2 Architect Registration r STATE ,' By Check CONSTRUCTION -- RD OCT U,3 Mr CENTER All ideas, deigns, arrangements, dfl I plans indicated or represented by this drawing are owned by and tlie property of Daems 8 Myers Architectural Alliance, Inch and we ce created, evolved, and developed for use on and in connei Lion with the specified propel. None of such ideas, designs, arrangements or plans shall be used by or disc kited to any person, firm, or rtxpxxation fix any purpose uw whatsoever without the written permission of DMAA _.. ..�..... 0 i PACHANICAL PLAN NOTES 0 1� PLUMBING CONTRACTOR INOORROU E REQUI CONDENSATE D PE PIPING �/ TO NEAREST ROOF D LANDLORD AND LOCAL CODE. () PROVIDE DRY TYPE SPRINKLER HEADS IN WALK - INS AS REQUIRED PER NFPA 13. t3�► NEW ROOF MOUNTED HVAC UNIT ON NEW CURB. CONFIRM VV EXACT LOCATION OF UNIT PRIOR TO INSTALLATION. NOTIFY ENGINEER IMMEDIATELY IF OBSTRUCTIONS PROHIBIT INSTALLATION. 0 120 V SERVICE TO BE LOCATED WITHIN 25 FEET OF AND ON THE SAME LEVEL AS THE ROOF MOUNTED EQUIPMENT FOR SERVICE AND MAINTENANCE. SEE ELECTRICAL FOR MORE INFORMATION. a OUTSIDE AIR INTAKES FOR HVAC SYSTEM SHALL NOT BE LOCATED CLOSER THAN 10' FROM SANITARY VENTS, APPLIANCE VENTS, OR EXHAUST FAN DISCHARGE. GENERAL NOTES: SCHEDULE BALANCING WITH THE OWNER'S FIELD REPRESENTATIVE. PROVIDE A COPY OF THE CERTIFIED AIR BALANCE REPORT AND CERTIFIED OUTSIDE AIR REPORT TO THE OWNER PRIOR TO OCCUPANCY. 2. FLEXIBLE DUCT SHALL BE LIMITED TO A MAX. LENGTH OF 6' -0" PER BRANCH RUNOUT. ELBOWS SHALL BE INSTALLED TO MAINTAIN A ONE AND ONE -HALF DIAMETER CENTERLINE RADIUS. 3. FILTER MEDIA SHALL BE UTILIZED TO PROTECT ALL RETURN OPENINGS DURING CONSTRUCTION. 4. A FREE AREA FOR MAINTENANCE ACCESS AROUND THE HVAC EQUIPMENT SHALL BE PROVIDED. MECHANICAL PLAN CONSTRUCTION NOTES REFER TO OWNER'S SPECIFICATIONS FOR MORE INFORMATION AND COORDINATION WITH OTHER TRADES. 1. IT IS REQUIRED THAT THE MECHANICAL CONTRACTOR MUST VISIT THE JOBSITE TO FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS, PLUMBING LOCATIONS AND ELECTRICAL RUNS. ADDITIONALLY, MECHANICAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS H.V.A.C. UNITS, DUCTWORK, ETC., PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE ANVOR PRE - DETERMINE ALL EXISTING CONDITIONS BEFORESUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE OWNER'S FIELD REPRESENTATr;'E FOR RESOLUTION. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES AND LANDLORD'S REQUIREMENTS. 3. UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE HEATING, VENTILATING AND AIR CONDITIONING WORK WHICH INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: A. NEW AIR CONDITIONING UNIT (V -01) SHALL BE FURNISHED BY JAMBA AND INSTALLED BY CONTRACTOR AS SCHEDULED ON THE DRAWINGS. B. REMOVE ALL EXISTING DUCTWORK AND EQUIPMENT NOT TO BE RE -USED AND DISPOSE OF SAME OFF LANDLORD'S PREMISES. C. FURNISH AND INSTALL ALL NEW DUCTWORK INCLUDING GRILLES, DIFFUSERS AND DAMPERS IN ACCORDANCE WITH S.M.A.C.NA CURRENT STANDARDS AND THE LANDLORD'S REQUIREMENTS - (SHOWN ON PLANS AS SOLID LINES). 1) ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE, AND BEAR UNDERWRITER'S AND UNION LABELS WHERE SUCH LABELING APPLIES. 2) ALL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET METAL OR PRE - INSULATED ALUMINUM CORRUGATED FLEXIBLE DUCT IN ACCORDANCE WITH THE STANDARD OF AMERICAN SOCIETY, REFRIGERATION AND AIR CONDITIONING ENGINEERS NATIONAL ASSOCIATION, FOR LOW PRESSURE, LOW VELOCITY DUCTWORK OR AS PER LOCAL CODE. 3) BRANCHES FROM MAIN LOW VELOCITY TRUNK DUCTWORK SHALL BE FURNISHED WITH SPUTTERS, DAMPERS OR SIMILAR BALANCING DEVICES IN ACCORDANCE WITH THE STANDARDS OF THE ASSOCIATED AIR BALANCING COUNCIL. (FIRE DAMPERS SHOULD BE PROVIDED AS REQUIRED BY ANY APPLICABLE CODES AND /OR JURISDICTIONAL AUTHORITIES). 4) ALL DUCTS FOR FINAL CONNECTION TO DIFFUSER SHALL BE CLASS 1 U.L. LISTED (SL 181) FLEXIBLE AIR DUCT NOT TO EXCEED 6' -0" IN LENGTH (THERMAFLEX, GLASSFLEX OR APPROVED EQUAL). 5) SUPPLY AND RETURN DUCTWORK SHALL BE INSULATED WITH ONE (1) INCH THICK MINIMUM BLANKET INSULATION WITH VAPOR BARRIER. ACOUSTICAL LINER MAY BE PROVIDED AS REQUIRED PER NFPA STANDARDS, I.R.I. REQUIREMENT AND UL RATED. (EQUAL TO MANVILLE FIBERGLASS INSULATION) 4. ALL COMPONENTS AND EQUIPMENT SHALL BE PROVIDED WITH AN EASE OF SERVICE AND MAINTENANCE AS REQUIRED BY CODE AND THE LANDLORD. 5. FURNISH AND INSTALL THERMOSTAT AS SHOWN ON THE PLAN AT A MIN. OF 3FT -MAX. OF 4FT A.F.F. (VERIFY LOCAL CODES). COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. PROVIDE CONTROL WIRING AND CONTROLS AS REQUIRED. 6. CONTRACTOR SHALL PROVIDE BROCHURES FOR ALL EQUIPMENT AND DEVICES TO THE OWNER FOR HIS REVIEW AND /OR APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 7. CONTRACTOR SHALL FURNISH A/C UNIT FILTER REPLACEMENT AFTER CONSTRUCTION IS COMPLETE. 8. INSTALLATION ACCEPTANCE MAY BE SUBJECT TO CONSTRUCTION REVIEW BY AN INDEPENDENT NR CONDITIONING FIRM. 9. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL TEST, START -UP AND BALANCE THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED TO INSURE PROPER WORKING ORDER. SUBMIT A COPY OF AIR BALANCE REPORT BY AN OUTSIDE CERTIFIED AIR BALANCE TECHNICIAN AND A COPY OF REPRODUCIBLE SET OF THE "AS BUILT" DRAWINGS TO THE OWNER AND TO THE LANDLORD FOR THE RECORDS, AND TO THE DESIGN ENGINEER'S OFFICE PRECEDENT TO FINAL PAYMENT. WALK —IN COOLER COMPRESSOR MOTOR LOCATED DIRECTLY ABOVE ON ROOF (TYP) 24 "x24" PERF. FACE RETURN AIR GRILLE, TITUS (PAR) LAY —IN BORDER TYPE -3 FOR T —BAR APPLICATION (TYP) WALK—IN COOLER COMPRESSOR MOTOR LOCATED DIRECTLY ABOVE ON ROOF (TYP) • 24 "X24" PERF. FACE CEILING DIFFUSER, TITUS (PAS) LAY —IN BORDER TYPE -3 FOR T —BAR APPLICATION (TYP). \[\\ 0 20x12 r 'O 320 CFM 12 THERMOSTAT FOR V -01. MECHANICAL PLAN 1/4- seD EQUIPMENT SCHEDULE LENNOX MODEL #LGA048 GAS FIRED PACKAGED ROOF TOP UNIT. NOMINAL COOLING CAPACITY: 4.0 TONS; 48,000 BTUH HEATING: 78,000 BTU, INTERMITTANT SPARK IGNITION, SINGLE STAGE. VOLTAGE: 208/230 -3 -60; MCA: 30 AMPS; MOCP: 40 AMPS 1600 CFM S.A. 0 0.60" E.S.P. 100 CFM O.A. MINIMUM SETTING. OPERATING WEIGHT: 740 LBS. PROVIDE WITH SENSIBLE CONTROLLED ECONOMIZER DAMPERS; DISCONNECT SWITCH; SEVICE OUTLET; POWER EXHAUST FAN. "LIGHTSTAT" MODEL TMD- AVU -RS AUTO - CHANGEOVER; 7 -DAY PROGRAMMABLE, NIGHT SET BACK; 5- DEGREE DEAD BAND; WITH INTERLOCK; THERMOSTAT FURNISHED AND INSTALLED BY G.C. SEE CONTROL WIRING DIAGRAM ON SHEET M2.0 NOTE: DO NOT LOCATE UNDER NIGHT LIGHT FIXTURE AND ON WALLS IN CUSTOMER'S AREA. "LIGHTSTAT" TMD - REMOTE SENSOR MOUNT AT 60" AFF. 1 3 North a SENSOR FOR V -01. SYMBOL LEGEND x R/A E.F. E] S P.O.C. OBD NEW 24 "X24 ", 4 —WAY PERFORATED FACE CEILING DIFFUSER FOR T —BAR APPLICATION EXISTING CEILING DIFFUSER NEW 24 "X24" PERFORATED FACE RETURN AIR GRILLE FOR T —BAR APPLICATION EXISTING RETURN AIR GRILLE ACCESS PANEL EXHAUST FAN THERMOSTAT REMOTE THERMOSTAT SENSOR DUCT SMOKE DETECTOR POINT OF CONNECTION UNDERCUT DOOR OPPOSED BLADE DAMPER I MVD --- ---- -� CFSD AFD NEW DUCTWORK EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK ;/, TO BE REMOVED FLEXIBLE AIR DUCT �1 CHANGE OF DUCT SIZE MANUAL VOLUME DAMPER COMBINATION FIRE /SMOKE DAMPER APPROVED FIRE DAMPER 0 ABD AUTOMATIC BACKDRAFT DAMPER (N) NEW (E) EXISTING W/H WATER HEATER jamba juice STORE #000 (S.0) SOUTIICE1■17ER MALL 6JSouth�nter #F6?O Thkwila, wasp DAEMS & MYERS ARCHITECTURAL ALLIANCE, INC. 301 WEST 5400 SOUTH /200 SALT LAKE CITY, UTAH 84107 PH: (801) 263 -3457 / FAX: (801) 263 -3529 Consultant Consultan • _ . istration Issues an ' Revisions No. Date 0 �I • Project Name SOUTHCENTER MALL Project Number Description Computer File jjECIArnl0.dwg Scale 1 /4 "a1r -0" Template 5.0 2 l a Boulder Engineering, LLC 811 West Cedar Pocatello, Wahl 83201 (208) 478 -4613 (208) 478 -4617 (fax) email beng @bengllc.com J Issues 1 7-18-03 CONSTRUCTION TWJ CDH 2 8 -20 -03 HEALTH DEPT. TWJ CDH 3 9-30-03 LANDLORD /OWNER COMMENTS TWJ CDH STORE 1 000 MECHANICAL FLOOR PLAN All ,tleji, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of Daems S, myers Architectural Alliance, IncQand were created, evolved, and dt•<..IoIied for use on and in connection with the specified project. None t,+ such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose %hatsoever without the written permission of DMAA Q M1. 159 • Architect Registration e sTA C c ertf ab wit.A ncT T goo 3 r , By Check • • 4 • GENERAL NOTES 3. PLUMBING CONTRACTOR: A. DUCTWORK: B. INSULATION: • • NOTES: 1. SET THERMOSTAT AS FOLLOWS - 75'F COOLING - 70'F HEATING 3. DO NOT INSTALL NEAR NIGHT LIGHT. 2. SOUND LINE (SL) AND EXPOSED TO WEATHER DUCTWORK: 1 1/2" THICK 1.5 TO 3 LB /CU.FT DUCT LINER. 208/230V - 3 -60 1 DISC. PACKAGED ROOFTOP 0 0 0 0 0 0 0 0 0 0 2. LABEL SHALL BE PLACED BELOW T -STATS SHOWING T -STAT SETTINGS. LABEL SHALL BE CONSTRUCTED OF BLACK BAKELITE w/ WHITE CENTER ENGRAVED LETTERS 3/16 ' HIGH. 4. INSTALL IN VICINITY OF MANAGER'S DESK. 1. GENERAL CONTRACTOR: A. FURNISH ROOF BASES TO AIR CONDITIONING UNITS, CUTTING AND PATCHING 2. ELECTRICAL CONTRACTOR: A. FURNISH AND INSTALL CONDUITS, LINE AND LOW VOLTAGE WIRING, FINAL CONNECTION TO AIR CONDITIONING UNITS AND ALL ITEMS NOTED ON THE DRAWINGS AS BY ELECTRICIAN. ALL WIRING SHALL CONFORM TO LOCAL CODES. A. PROVIDE AND INSTALL TRAPPED CONDENSATE LINES TO APPROVED RECEPTACLES, FINAL CONNECTION TO AIR CONDITIONING UNITS. 4. AIR CONDITIONING: A. ALL MATERIALS SHALL COMPLY WITH GOVERNMENT CODES, SAFETY ORDERS AND REGULATIONS. OBTAIN AND PAY FOR ALL NECESSARY PERMITS, FEES AND INSPECTION REQUIRED BY THE GOVERNMENT AUTHORITIES. 1. ALL DUCTWORK SHALL BE CONSTRUCTED CONFORMING TO SMACNA CURRENT STANDARDS AND TO GOVERNING CODES. ALL SEAMS OF SUPPLY AIR PLENUMS, RETURN AIR PLENUMS, SUPPLY AND RETURN DUCTWORK SHALL BE TAPED WITH 4" WIDE, 20 OZ. WEIGHT CANVAS WITH ARABOL LAGGING COMPOUND. 1. CONCEALED DUCTWORK: SUPPLY AND RETURN DUCTS SHALL BE INSULATED WITH 1" THICK AND 3/4 LB. DENSITY FIBERGLASS BLANKET 5. THE TOTAL INSTALLATION SHALL COMPLY WITH ANY AND ALL REQUIREMENTS OF THE LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION INCLUDING THE CITY CODES, STATE FIRE MARSHALL AND NFPA PAMPHLET 90 (LATEST ENFORCED EDITION). IN CASE OF CONFLICTS WITH IN CODES, DRAWINGS OR SPECIFICATIONS THE MOST STIRNGENT REQUIREMENT SHALL PREVAIL. 6. WITHIN THIRTY (30) DAYS OF AWARD OF THE CONTRACT, SUBMIT TO THE OWNER, SIX (6) COPIES OF A COMPLETE LIST OF MATERIALS AND EQUIPMENT PROPOSED FOR THE JOB INCLUDING ALL DATA, PART NUMBER, RATING CAPACITY, SIZE, DIMENSIONS, ELECTRICAL DATA, GRADE, PART NUMBER, MANUFACTURER, ETC. FOR ALL ITEMS SHOWN ON THE MECHANICAL PLANS ALONG WITH SHOP DRAWINGS. INCOMPLETE SUBMITTALS SHALL BE REJECTED AND RETURNED TO THE CONTRACTOR FOR CORRECTIONS WITHOUT REVIEW. NO WORK SHALL BE STARTED UNTIL SHOP DRAWINGS ARE APPROVED. 0 0 9. 0 0 0 0 AUTO - CHANGEOVER THERMOSTAT "LIGHTSTAT" MODEL # TMD -AVU NOT TO SCALE 11. LEGEND M ITEMS FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. (INCLUDING ALL LINE AND LOW VOLTAGE WIRING AND CONDUIT) (ME) RTU WIRING DIAGRAMS ITEMS FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. (INCLUDING ALL LINE AND LOW VOLTAGE WIRING AND CONDUIT) 7. THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT DUCTS, ALL OFFSETS, BENDS, SPECIAL FITTINGS AND LOCATIONS ARE NOT EXACTLY LOCATED AND ARE NOT BE SCALED. 8. THE CONTRACTOR SHALL COMPLY WITH ALL CONTRACT DOCUMENTS IN LAYING OUT HIS WORK AND EQUIPMENT AND HE SHALL BE FAMILIAR WITH ALL ARCHITECTURAL, PLUMBING, FIRE SPRINKLER AND ELECTRICAL DRAWINGS. HE SHALL COORDINATE THE WORK OF THIS SECTION WITH THE WORK OF OTHER TRADES AND ALL THE JOB SITE CONDITIONS. THE INSTALLATION OF DAMPERS, DUCT ACCESS DOORS OR OTHER INDICATED EQUIPMENT OR SPECIALTIES REQUIRING READING, ADJUSTMENT, INSPECTION REMOVAL OR REPLACEMENT SHALL BE ACCESSIBLE AND CONVENIENTLY LOCATED WITH REFERENCE TO THE TO THE FINISHED BUILDING. (COORDINATE WITH ARCHITECT). 10. INSTALL FIRE DAMPERS IN DUCTS PASSING THROUGH FIRE WALLS, AND FIRE RATED CEILINGS. ENTIRE INSTALLATION MUST BE LISTED APPROVED BY THE STATE OF FIRE MARSHAL'S OFFICE. IT IS THE MECHANICAL CONTRACTOR'S RESPONSIBILITY IS TO INVESTIGATE THE AVAILABLE VOLTAGE PRIOR TO PURCHASING THE EQUIPMENT. SHOULD THE VOLTAGE NOTED IN PLANS NOT BE AVAILABLE AT THE SITE, IT IS THE MECHANICAL CONTRACTORS RESPONSIBILITY TO PAY FOR ALL THE EXPENSES TO PROVIDE REQUIRED TRANSFORMERS TO OPERATE THE HVAC UNIT AT NO COST TO THE OWNER OR MECHANICAL CONSULTANT. FRESH AIR INTAKES FOR HVAC UNIT SHALL BE MINIMUM 10' AWAY FROM EXHAUST OUTLETS. DUCT SIZES NOTED ON PLANS ARE NET. CLEAR INSIDE DIMENSIONS. FURNISH A WRITTEN GUARANTEE FOR THE PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE OF WORK BY OWNER TO THE OWNER AND ARCHITECT. 15. THE CONTRACTOR SHALL INSTRUCT OWNER OR HIS AGENT IN ALL DETAILS OF THE OPERATION OF THE AIR CONDITIONING SYSTEMS. 16. PROVIDE FOUR (4) COPIES IN HARDCOVER THREE RING BINDERS CONTAINING COMPLETE MANUFACTURER'S INSTRUCTIONS, MAINTENANCE AND PARTS LISTS ON ALL EQUIPMENT INCLUDING CONTROLS TO OWNER OR HIS AGENT. 17. PROVIDE JAMBA JUICE WITH TWO (2) SETS OF AS -BUILT RECORD DRAWINGS. 18. IT IS A PREREQUISITE OF THIS PROJECT THAT ALL RESPONSIVE BIDDERS WILL VISIT SITE PRIOR TO BIDDING THIS JOB AND FAMILIARIZE THEMSELVES WITH ACTUAL JOB SITE CONDITIONS. SUBMITTAL OF BID SHALL INDICATE THE CONTRACTOR HAS EXAMINED THE SITE AND DRAWINGS AND HAS INCLUDED THIS, AS REQUIRED IN HIS BID. NO ALLOWANCE SHALL BE MADE FOR ANY ERROR RESULTING FROM CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND TO REVIEW DRAWINGS. BID SHALL INCLUDE COSTS FOR ALL AT NO COST TO JAMBA JUICE. • FIBERGLASS INSULATION (FURNISHED) LEVELING OF FRAME BY OTHERS 24. IF REQUIRED BY LOCAL CODES, ALL EQUIPMENT AND DUCTWORK SHALL BE PROVIDED WITH SEISMIC RESTRAINT AS PER SMACNA (91 ED.). 27. DUCTWORK INSULATION ROOF B. PULL JACKET AND INSULATION BACK OVER THE CORE AND USE TWO WRAPS OF APPROVED TAPE OR AN APPROVED CLAMP. NEW ROOF MOUNTING FRAME DUCT THRU ROOF NOT TO SCALE CURB MOUNTED A/C UNIT 19. COORDINATE EXACT LOCATION OF DUCTWORK, AIR INTAKES AND APPURTENANCES WITH OTHER TRADES BEFORE FABRICATION AND INSTALLATION. DO NOT SCALE THE DRAWINGS FOR LOCATION OF EQUIPMENT AND DUCTWORK. THESE DRAWINGS ARE FOR PLAN CHECK PURPOSES ONLY. SHOP DRAWINGS (i.e., DETAILED LAYOUTS COORDINATED WITH ALL OTHER BUILDING SERVICES; STRUCTURAL, ELECTRICAL CONTRACTOR, FIRE SPRINKLER CONTRACTOR AND PLUMBING CONTRACTOR REQUIREMENTS MADE IN THE FIELD WHICH REFLECT ACTUAL SITE CONDITIONS) NEED TO BE PROVIDED TO THE ARCHITECT /OWNER BEFORE INSTALLATION. USE DIMENSIONED STRUCTURAL AND ARCHITECTURAL DRAWINGS FOR COORDINATION PURPOSES. COORDINATE EXACT LOCATIONS WITH RELATED TRADES BEFORE BEGINNING WORK. ROOF CURB INSTALLATION 20. DUCT SMOKE DETECTORS SHALL BE FURNISHED AND WIRED BY MECHANICAL CONTRACTOR AND SHALL BE INSTALLED BY MECHANICAL CONTRACTOR IN R.A. DUCTS OF UNITS WITH CAPACITY OF 2,000 CFM AND OVER. PER LOCAL CODE, TO SHUT DOWN THE UNITS IN THE EVENT SMOKE IS DETECTED. CONTRACTOR SHALL PROVIDE A REMOTE TEST / INDICATOR FOR EACH DETECTOR MOUNTED ON CEILING IN THE SALES AREA BELOW UNIT. 21. PROVIDE MISCELLANEOUS STEEL AND /OR WOOD BLOCKING FIRE TREATED AND SUPPORT AT ROOF CURBS AND OPENINGS AS REQUIRED TO SUPPORT ROOF AND EQUIPMENT. SPECIFIC REQUIREMENTS SHALL BE VERIFIED WITH ARCHITECT AND APPROVED EQUIPMENT DRAWINGS PRIOR TO PLACEMENT. 22. CONSTRUCTION DUST AND DEBRIS SHALL BE REMOVED FROM ALL SUPPLY DIFFUSERS AND RETURN GRILLES AND SHALL BE VACUUMED FROM DUCTS AND DUCT LINER BEFORE START UP. 23. MECHANICAL CONTRACTOR MUST OBTAIN AND PAY FOR ALL PERMITS AND APPROVALS NORMALLY ASSOCIATED WITH INSPECTION OF WORK UNDER THIS SECTION. 25. ACCESS PANELS MUST BE PROVIDED FOR ALL LANDLORD OR TENANT EQUIPMENT WHICH IS ABOVE THE CEILING IN HARD CEILING AREAS. ACCESS PANELS MUST BE PAINTED TO MATCH ADJACENT CEILING FINISHES. 26. HVAC CONTRACTORS REQUIRED TO CHANGE FILTERS, PREPARE TEST AND BALANCE REPORT. CONTRACTOR WILL NOT BE PAID UNTIL JAMBA JUICE DEEMS AIR CONDITIONING SYSTEM IS SUITABLE AND CORRECT FROM AN OUTSIDE HVAC CONSULTANT. 27. DUCT CONNECTIONS TO BE WRAPPED WITH LISTED UL 181 TAPE IN ACCORDANCE WITH THE FOLLOWING: A. ATTACH THE INNER CORE TO THE COLLAR WITH AT LEAST TWO WRAPS OF APPROVED DUCT TAPE AND SECURE WITH AN APPROVED CLAMP. A. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A • NEOPRENE GASKET MICROMETAL WS- 9403 -02 6" WIDE, 16 GA., SEISMIC STRAP SECURED TO UNIT & CURB (MIN. 4 PER UNIT OR AS RECOMMENDED BY MICROMETAL (4) #10 X 1/2" TEK SCREWS FOR EACH SEISMIC STRAP. .K. NAILER (FURNISHED) JJ COUNTER FLASHING BY OTHERS RIGID INSULATION BY OTHERS 3/8" X e LAG SCREW AT EACH CORNER OF UNIT CANT STRIP BY OTHERS ROOFING ROOF JOIST OR BLOCKING. PROVIDE 4X6 BLOCKING AS REQUIRED BETWEEN ROOF JOISTS WITH SIMPSON HUS46 HANGERS. cglAgfr � cl 2 soil) B. DUCTWORK SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INCREASE DUCTWORK SIZES AS REQUIRED FOR INTERNALLY LINED DUCTWORK TO MAINTAIN INSIDE CLEAR DIMENSIONS. C. ALL SUPPLY AND RETURN DUCTWORK WITHIN 15 FEET OF THE AC UNIT INSIDE THE BUILDING SHALL BE INTERNALLY LINED. INTERNAL LINING SHALL BE 1 -INCH THICK, 1-1/2 LB DENSITY LINER. LINER SHALL HAVE A COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES SHALL BE COATED WITH ADHESIVE. D. INSULATE ALL OF THE FOLLOWING DUCTWORK: 1. CONCEALED SUPPLY DUCTWORK THAT IS NOT INTERNALLY LINED 2. UNTREATED OUTSIDE AIR DUCTWORK LOCATED WITHIN THE INTERIOR 3. EXTERIOR SUPPLY & RETURN DUCTWORK E. EXTERNAL INSULATION SHALL BE REINFORCED FOIL FACED, VAPOR SEALED FIBREGLASS. INSTALLED THERMAL RESISTANCE (DEG F -SQ FT -HR /BTU) SHALL BE AT LEAST 4.5 (1 1/2") FOR INTERIOR DUCTWORK AND 9.0 (3 ") FOR EXTERIOR DUCTWORK, OR AS REQUIRED BY LOCAL CODES, WHICHEVER IS MORE STRINGENT. PROVIDE EXTERIOR DUCTWORK INSULATION WITH WEATHERPROOF JACKETING. F. COVER INSULATION WITH 'FSK' JACKET. COVER WITH AN ADDITIONAL JACKET OF GLASS CLOTH, EMBEDDED IN A THICK COAT OF EQUAL TO BENJAMIN FOSTER 30 -35. APPLY ANOTHER COAT OF CEMENT OVER THE GLASS CLOTH. G. ALL INSULATION AND LINING SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. H. DUCTWORK EXPOSED TO THE WEATHER SHALL BE MADE WATERPROOF BY SEALING ALL SEAMS WITH HARDCAST TAPE, APPLIED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. AS ADDITIONAL WEATHER PROTECTION, APPLY ONE COAT OF ALUMINUM PAINT TO ALL OF THE TAPE. I. INSULATION OVER ANGLES AND STANDING SEAMS SHALL BE MINIMUM OF 1 INCH THICK. WHERE ANGLES AND STANDING SEAMS PROJECT FROM DUCTS, BANDS OF INSULATION AT LEAST 4 INCHES WIDE SHALL BE INSTALLED TO PROVIDE ADEQUATE COVERAGE. J. ACCESS PANELS AND DOORS OF SURFACES SPECIFIED TO BE INSULATED SHALL BE INSULATED ALSO UNLESS NOTED OTHERWISE. SHEET METAL COVERS SHALL BE INSTALLED OVER EDGES OF INSULATION AT ACCESS PANELS OR DOORS, BOTH ON THE PANELS OR DOORS AND ON ADJACENT SURFACES. jamba juice STORE #000 (S.0) MUMMER MALL, 680 Southcenter #F670 Tulrwile, WA 9161 I • • • • DAEMS & MYERS ARCHITECTURAL ALLIANCE, INC. 301 WEST 5400 SOUTH 1200 SALT LAKE CITY, UTAH 84107 PH: (801) 263 -3457 / FAX: (801) 263 -3529 Consultant Consultant Registration EXPIRES 1/01/04 Issues and Revisions No. Date Boulder Engineering, LLC 811 West Cedar Pocatello, Idaho 83201 (208) 478 -4613 (208) 478 -4617 (fax) email bong @bcngllc.com Architect Registration Issues By Check 1 7 - 18 - 03 CONSTRUCTION TWJ CDH 2 8 -20 -03 HEALTH DEPT. TWJ CDH 3 9 -30 -03 LANDLORD /OWNER COMMENTS TWJ CDH Trms”te Project Name SOUTHCENTER MALL Project Number Description STORE 1 000 Computer File jJSCMm20.dwg Scale AS NOTED � G T 0 1 2003 PesmT com Template 5.0 (10/3' ; 0� GENERAL Notes / SPECIFICATIONS All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of Daems & Myers Architectural Alliance, IncQand were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of DMAA Q M2.O mo 15? • • • I