Loading...
HomeMy WebLinkAboutPermit M03-182 - GALLIANO'S CUCINAGALLIANO'S CUCINA 14201 INTERURBAN AVENUE SOUTH M03-182 re al2 6 JU 00 U)p' W = N Cl).. u O 2 IL Q N d' H w Z I, I- a Z F--; w U� w UJ' V' "; z: O~' z Tenant: Name: Address: Owner: Name: Address: City of fukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3365901470 Address: 14201 INTERURBAN AV S TUKW Suite No: GALLIANO'S CUCINA 14201 INTERURBAN AV S, TUKWILA WA THE SOUTHLAND CORP C/O TAX DEPT LOC 27482, PO BOX 711 Contact Person: Name: MIKE LEAHY Address: 727 S KENYON ST, SEATTLE WA Contractor: Name: EVERGREEN REFRIGERATION INC Address: 727 S KENYON, SEATTLE, WA Contractor License No: EVERGI *201D7 DESCRIPTION OF WORK: INSTALLING 2 HVAC UNITS, 4 EXHAUST FANS AND ASSOCIATED DUCTWORK. Value of Construction: $17,000.00 Type of Fire Protection: SPRINKLERS MECHANICAL PERMIT Permit Center Authorized Signature: /i %t.46-L (ie:/./; Q Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 763 -1744 Phone: 206 - 763 -1744 Expiration Date:07 /31/2004 M03 -182 12/11/2003 06/08/2004 Fees Collected: $124.44 Uniform Mechnical Code Edition: 1997 Date: //1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: (2 6 ,-,Th Print Name: Aga . I `y Rcs doc: Mech M03 -182 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 12 -11 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 3365901470 Permit Number: M03 -182 Address: 14201 INTERURBAN AV S TUKW Status: ISSUED Suite No: Applied Date: 10/30/2003 Tenant: GALLIANO'S CUCINA Issue Date: 12/11/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 10: Manufacturers installation instructions required on site for the building inspectors review. 11: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 12: Fuel burning appliances may not be installed in sleeping rooms, U.M.C. 304.5. 13: Appliances which generate flame, spark or glowing ignition, shall be elevated 18 inches above the floor (U.M.C. 303.1.3.). 14: Water heater shall be anchored to resist earthquake (U.P.C. 510.5). 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: doc: Conditions M03 -182 Printed: 12 -11 -2003 ...' • i.fy �•r iLL.J 'i� cc yaw.•: S' 17: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 18: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 19: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 20: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 21: Duct detectors shall send a supervisory signal only upon activation. 22: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 23: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 24: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 51.1. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: / )// V0 3 Print Name: j JCJcc''u I - ./Q\ 5 doe: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 M03 -182 Printed: 12 -11 -2003 Site Address: t 1- 12-0 \ . _'J » y Tenant Name: GALLc.4,�tj G��Crt Property Owners Name: AA-12.4., Mailing Address: Name: E -Mail Address: Company Name: Cs/ ¢L t�An.l r; S • Contact Person: ,,Ajq-�4 t --1-L 10 E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: \applicationstpennit application (3.2003) 3/2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Soulhcenter Blvd., Suite 100 Tukwila, WA 98188 Building Penult '.No Mech Perm Public Works Permit Project Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Mailing Address: ?Z City or office use' only CATI King Co Assessor's Tax No.: Suite Number: Floor: I New Tenant: ••.. Yes ..No State 1 .. Zip TACT-PERSO Day Telephone: y66 - 763 -1 7`I �• m--e._ (A)*- gg166 City State Zip Fax Number: 2P7- - 23S. 7 Mailing Address: /Z - c� .42 j o o cam : 5'>= ¢rst C LJA-- City State � �f � tp Day Telephone: 2-41 - 3- 7 66 Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF REC plans :must be wet stamped by Architec Company Name: Mailing Address: Zip Contact Person: E -Mail Address: Page 1 City Day Telephone: Fax Number: State ENGINEER OF RECORD All,'plans must be.wet stamped by Engineer of Recori • .. .'. . .ems /:_�t Y �. ,. .. .... ! ...f. i_. •.:..r .. .., r '.... .� .. �. t. State Zip City Day Telephone: Fax Number: 'BUILDING PERMIT 1NFORMA.I'ION. := 206 431 = 3670 , Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ ..Yes ❑.. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: \applications \penult application (3.2003) 3/2003 Page 2 Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ED ..Yes ❑ ..No If "yes", attach list of materials and storage locations on a separate 8-1/2 x 11 paper indicating quantities and Material Safety Data Sheets. ..: 1 y � L1C es, Scope of Work (please provide detailed information): Proposed Activities (mark boxes that apply): 0 ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Ri -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ ,. Easement(s) ❑ .. Cut ❑ ...Total Fill ❑...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ... Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO# ❑ ...Temporary Water Meter Size.. WO# ❑ ...Water Only Meter Size WO# ❑ ...Sewer Main Extension Public Private ❑ ...Water Main Extension Public Private FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: \applications\permit application (3.2003) 3/2003 ;S: :PERMYT:YNF tMATIO] cubic yards cubic yards i 206- 433.017 Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line „ ❑ r. Highline Sewer District ❑ ...Tukwila 0... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage Number of Public Fire Hydrant(s) ❑ ... Sewage Treatment Page 3 ❑ ...Deduct Water Meter Size Day Telephone: City ❑ ...Renton ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding State Zip Day Telephone: City State Zip Z W re O 0 N J W 1 Q to � d ▪ W Z I- 0 Z W 0 O D O 1— W W u W Z 0I Z Unit Type: Qty. Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >100K BTU 2... Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan '-1 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Flood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind ECIIOIGAL PERMIT INFO ..AVIATION =106-431 MECHANICAL CONTRACTOR INFORMATION Company Name: i ve-TyC RF.35.t1 12 GRr e%t) :t Mailing Address: `727 S Contact Person: M -Kr-, E -Mail Address: Contractor Registration Number: FA) .i7 I .D'7- Expiration Date: 7 3 I G� * *An original or notarized copy of current Washington State Contractor License must be presented at the ime of permit issuance ** Valuation of Project (contractor's bid price): $ \'1 Scope of Work (please provide detailed information): t t ' . - tL 2 t-} U h C— .E///41.)S t ( A M 5 ANT) >v 9 wog— Use: Residential: New .... Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric Gas .... Other: \appliations\permit application (3.2003) 3/2003 Indicate type of mechanical work being installed and the quantity below: Page 4 V. city Day Telephone: 1, State Zip 70h— 7 9 — L 7 Fax Number: Za6 - 7d 5 25 ,5'7 ERMIt'AP PLICATION NOTES Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Qi13\'P.prC bA Print Name: \kaeL)1\\ QjacCCb� Mailing Address: `72 7 S \(---e_t=4 Date: )0/6)/ Day Telephone: )D6 — 6 i - 5 clq City State Zip Date Application Accepted: /e se-- v 3 Date Application Expires: Staff Initials: S Y i ACCOUNT ITEM LIST: Description Account Code Current Pmts z RECEIPT < l re 2 Parcel No.: 3365901470 Permit Number: M03 -182 6 = Address: 14201 INTERURBAN AV S TUKW Status: APPROVED U O Suite No: Applied Date: 10/30/2003 c o w Applicant: GALLIANO'S CUCINA Issue Date: _1 H WO Receipt No.: R03 -01477 Payment Amount: 124.44 1 Q . u)= Initials: LAW Payment Date: 12/11/2003 03:01 PM H w User ID: 1630 Balance: $0.00 = zI I- 0 z I - Payee: EVERGREEN REFRIGERATION INC D 0 0 O SP- o t— Ill =U Type Method Description Amount '— U.. F- O Payment Check 056086 124.44 Z Iii U co O ~' TRANSACTION LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 MECHANICAL - NONRES PLAN CHECK - NONRES 000/322.100 99.55 000/345.830 24.89 Total: 124.44 3563 12/15 9716 TOTAL 124.44 Printed: 12 -11 -2003 z Protect: 64/6 01&/0A Type of Iwection: Fhyi/A/ Address: _ /� / I / yaa/ _ /4erLlI / LA-A / Date Called: y -� " LI - v/ Special Instructions: Date Wanted: S _ 2 a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERM 206)431 -3670 hQ Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6i .Pe / - / B'�'✓� l 6)Z. 7 w nspect Date: —DC $ .00 REINSPECTION EE REQUIRFO. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. eceipt No.: 'Date: Z -- • Z . � W 6 U U O ND W = � LL WO u _ I Z 1 ._ : � W uj • en O —. W UJ I I-- 0 O W Z U - O Z Prt: , � � ���� Type of Ins ction: (I4 �`p 1 I(.ICJ / II a o A `7 �0 1 itffA l.,l�'z r Date Called: 5 Special Instructions: rei r ....., I. VD ate Wanted: ` a.m. Requester: r i , _ I�/J/�/', t n Ph on No: INSPECTION RECORD Retain a copy with permit 0 3 — +3 PERMIT INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 . pproved per applicable codes. `~-j required prior to approval. COMMENTS: M fie. 5 h144 ]7 rve Date: 2 o/,! y El $4 ' • ' REINSPECTION FEE' EQUIRED. Pri /r to inspection, fee must be pa • t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. receipt No.: Date: 2 Pr � ct: / � 1 I t7A /c Type of Inspe on: A r s ' Date Called: Specs I Instructions: r , Date Wanted: a.m: Ioy (.m. Requester: "°' N Phone �� — r D - 7q- .ir8o Approved per applicable codes. Date: rh a3 , -t ga INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 �ar fections required prior to approval. COMMENTS: (7) 3144 kuk clAddii? . 4 AA...cLA„-‘,\ L_ Dates i 47.00 REINS ECTION FEE EQUIRED. Prior to inspection, fee must e aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PP ijec : 7n/ ( - ` 5 Type of Inspection: u.oPe /�_ '- /4 �^ ? w: Address: / S / /4/ 7Z .4 /P Date Called: - 73 -o e-7 Special Instructions: J Date Wanted: 7 ".04/ C a.m p.m. Requeste : TA " T Ph 0 ) (79 - 5/O C/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERM( CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,(2 ' 6) J-3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ) T na 01- m I >`nrt%i L/ CLWLL b Date: 5/ 5 1.00 REINSPECTION FE REQUIRED. Prior o inspection, fee must be p aid at 6300 Southcenter lvd., Suite 100. C II to schedule reinspection. (Receipt No.: 'Date: Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location RTU -1 LENNOX LGA0900 -130 93000 3000 600 10.30 104000 ROOF RTU -2 LENNOX OCS16- 030 -75 27400 1000 200 10.0/8.7 60000 ROOF 240 0.38 2.2A RESTROOM Heating Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' RTU -1 LENNOX LGA090S -130 104000 3000 600 125000 104000 80.000 RTU -2 LENNOX GCS16- 030 -75 60000 1000 200 75000 60000 80.000 240 0.38 2.2A RESTROOM Project Info Project Address GALLINANO'S CUCINA Model No. CFM Date # # # # # # # ## HP /BHP 16435 MILITARY ROAD SOUTH Location of Service EF -1 For Building Dept. Use ..I I RECEIVED T OCT T 1 UKWILA O Applicant C f 3 0 2003 r)Cn. 4,............ UBCA -18 TUKWILA, WASHINGTON 0.50 1HP Applicant Name: Evergreen Refrigeration, Inc ILO Address: 727 South Kenyon Street, Seattle WA 98108 Applicant Phone: 206- 763 -1744 EF -3,4 GROAN Fan Equipment Schedule Equip. ID Brand Name Model No. CFM SP HP /BHP Flow Control Location of Service EF -1 ILO UBCA -18 3500 0.50 1HP HOOD EF -2 ILO CRHCA -100 700 0.40 1 /4HP HOOD EF -3,4 GROAN L250 240 0.38 2.2A RESTROOM 2001 Wa ^hington State Nonresidential Energ Code Corn- " Form Mechanical Summa MECH -SUM 2001 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans r •' CITY of APVRMD DEC ' nj3 k t, q h� t,i :i,f✓4 FILE COPY Include documentation requiring compliance with commissioning requirements, Section 1416. , 3 -/aL June 2002 • KJM INSTALL 2 HVAC UNITS, 4 EXHAUST FANS, AND ASSOCIATED DUCTWORK. Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following Information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill In the required information below. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <54,000 Btuh ❑ Economizer included? or 1900 cfm? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? r Mechanical Summ. (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only No 2001 WPo in ton State Nonresidential Ener• Code Comte " Form Yes 10. Heating/Cooling or Cooling Only Reference Section 1421 Yes Yes Yes Yes Reference Yes—* Section 1423 Reference Section 1420 Yes Simple System N Allowed Reference Section 1430 2001 Washington State Nonresidential Energy Code Compli- -e Form Mechanical Perm ' lans Checklist 2001 Washington Slate Nonresidential Energy Code Compliance Forms MECH -CHK June 2002 - KJM Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown In Table 14 -1A through 14-1G. If a nationally recognized certification program exists for a product covered In Tables 14 -1A through 14 -1G, and It includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) shall also have an intermittent Ignition or Interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with Input ratings 225,000 Btu /h (65 kW), Including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the fo lowing: 141t4 Packaged Electric Heating and Cooling Equlpmen : Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by Individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humldistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Blu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system Is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity ( nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets In the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating Is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, Including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulbl40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following Information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode, 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 Inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 Inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 14142 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements Include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be Isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally Insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. Exception: Piping Installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51-26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2001 Washington State Nonresidential Energy Code Compli- -e Form Mechanical Perm ' lans Checklist 2001 Washington Slate Nonresidential Energy Code Compliance Forms MECH -CHK June 2002 - KJM Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown In Table 14 -1A through 14-1G. If a nationally recognized certification program exists for a product covered In Tables 14 -1A through 14 -1G, and It includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) shall also have an intermittent Ignition or Interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with Input ratings 225,000 Btu /h (65 kW), Including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the fo lowing: 141t4 Packaged Electric Heating and Cooling Equlpmen : Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by Individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humldistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Blu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system Is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity ( nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets In the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating Is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, Including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulbl40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following Information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode, 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 Inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 Inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 14142 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements Include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be Isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally Insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. Exception: Piping Installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51-26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) Mechanical Perm lans Checklist MECH -CHK 2001 Washington State Nonresidential Energy Code Compliance Forms June 2002 - KJM Project Address OALLINANWS cvcxNA Dat 10/ 30/2003 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1411.4 Pkg. elec. htg.& cig. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Ml 1411.1 Combustion htg. Indicate Intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans Mi 1412.2 Deadband control Indicate 5 degree deadband minimum 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 duff. day types Ml yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage M1 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans Hi. 1422 Thermostat Interlock Indicate thermostat Interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & cig tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary Ml yes 1414.2 Duct Insulation Indicate R -value of Insulation on duct Ml. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.1&2 Drawings & Manuals Indicate requirement for record drawings and operation docs. yes 1416.3.2 Air Balancing Indicate air system balance requirements Ml 1416.3.3 Hydronic Balancing Indicate hydronic system balance requirements yes 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report Ml 1424 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer Ml • 2001 Washington State Nonresidential Energy Code Compli-- ^e Form. Date: OCT -20 -2003 16:11 FROM -BMC WEST To: Attention; Fax Number: Thank You, BMC WEST BUILDING MATERIALS - South Sound Commercial/ Multi- Family Division 10.29.2003 Evergreen Refrigeration; Design & Build Associates Matt Patton; Frank Nichols 206.763,2389; 360.825.8867 Project: Galllano's Cucina Restaurant From: BMC West Tacoma Commercial Truss Division Number of pages (including coversheet): 4 Matt and Frank, (copy to appropriate Building Official) Enclosed is a copy of the roof truss layout and flat truss supporting mechanical units. Loads have been applied per information provided by Evergreen Refrigeration. Trusses have been designed to carry both units at the same time, although it looks like this condition. will only exist on one truss.. Clouded figures and locations on engineering page represent concentrated loads and locations applied to truss. Any questions please feel free Dale S. i3ro n Commerci. /Multi - Family Projects Director 753-568-4535 Truss Information Fax T-086 P.001 /004 F-640 FILE COPY 0I1y O RECEIVED OCT 3 O 2003 PERMIr oENrER Cif CF. T i J i DEC Zi103 INCOMPLETE LTR #.4___ 9721 40 Avenue SW Tacoma, Washington 98499 -4395 Phone: 253.582.1444 Fax: 253.588:4535 Toll Free: 1.800.4BMCWEST z =H w et 2 J O 00 N co tu u. J H w (B. a = W F- _ z � zI w Lu N 0 N 0E- wW I - U LL ..z Uw 0 z OCT 2 9 ?liin a VUI *Wai• *loam vs.. Ivo to IP' 0 1 1' 1 0 1 •7 FO 20.0.4 7.1112 6•0•0 84 " a-0.0 I 9 xi olock.inc, Prort•ol 00.0-0 IA WA A t4 U T Telephone: Name: Address: ps-ri ikyt■ii11.1\ 0 • DV-C ti) Kz; Job: 9 9 I. 9 9 9 0 C09167-1 9 I0 Description: Galliano's Cucina Delivery 1 &.,-v.,, 12B Drawn By: DsB z z re 6" 6 0 _i 0 0 co co w W E u_ w 0 g 11 u. — a LLI 1 Z w 2 M 0 co • ( 12 • I— w w (Li • U) 0 Z U1.1 L•"LUUU in I Job Trust C09167 fPO1M IHM WESt 0.0.0 L 0•00 Ie12 4.5:5 4.53 PIi1 LOADING (psi) TCLL 25.0 TCDL 150 BCLi. 0.0 BCDL 10,0 LUMBER TOP CHORD DOT CHORD WEBS 111Un1 uNN III o I 744 7.44 4511 — Truss Type SL, 3 FLAT I s axis (X�►: [AO. 6.9,0 =2=01, 10,TPTc72 SPACING 2.0.0 Plalos Incleasa 1.15 Lumber Increase 1.15 Rep Slrees Iner NO Code UBC97 /ANSI95 2 X 4 HF 1850f 1.5E 2 X 4 HF 1650F 1.5E 2 X 4 HF Stud •Except• K -L 2 X 6 HF No.2, E -F 2 X 4 HF 1650F 1,5E 10.3 -12 5.10.9 [1:0.3 O,Edge) REACTIONS (Ib/size) K= 1005/0.5.6, F= 100510 -5 -e Max Hors K= 7d(load case 4) Moe Uplih K=- 117(loaa case 3), F=- 110(load case 5) Mel Gray K= 1290((oad case •I), F= 1320(lotld case 7) 4,6 — CSI TC 0.61 BC 0.77 WO 0.00 (Matrix) Taw Ply . (,7 1159) ceiiiana, G`uuna 7 2 • Job Reference (optional) _ ' 57000 a Jun 0 2003 MIT — Induatnee, Inc, W 3 Oct 00 10:31 :20 2003 Page 1 134.15 6.0.6 3.1 = BRACING TOP CHORD DOT CHORD 15.3.3 4•11•7 DEFL in (toe) Vert(11) .0.22 H Vert(TL) -0.82 H -J Hort(TL) 0.06 F 1st LC LL Min Udell c 240 FORCES (IN- First Load Case Only TOP CHORD A -K= -897. A•L =o, A•M =•3825, B -M= -3818, 0 -N= •5091, N.O= •5080. C -O =-5085, C -0=.5082. 0•P= -3363, E•P =378, 54=402 DOT CHORD J.K =807, I -J =5197. H -I =5197, G•H =4546, F•G =459 WEDS A -1=2051, (142.1051, B•H= -117, D•H =565, 0.01-1334.E-G=29£14 NOTES 1) 2 -ply truss to be connected together with 100 Com(non(.148 "4") Nails as follows: Top chords connected as lottow4: 2 X 4 -1 row at 0.4.0 oc, 2 X 0 rows at 0.0.0 oc. Bottom chords connected as fallow:;: 2 X 4 - 1 row at 0.0.0 oc. Webs connected us follows: 2 X 4 - 1 row at 0.9.0 oc, 2) This truss has Sean dosignod for the wind roads generated by 80 mph winds at 25 It abovo ground level, using 5,0 psf lop chard deed bad end 3.0 pal bottom chord deed load, in tho gable end roof 2006 on an occupancy Wager) II, condition I enclosed building, will, exposure B ASCE 7.95 per UBC97 /ANSI95 If end verticals or cantilevers esrsL they are exposed to wind. If porches exist, they Ara not exposed to wind. The lumbar DOL Moreau is 1.33, and Thu plate grip increase is 1,33 3) Providu adequate drainage to proven, water pending. 4) Tnls Ouse Ma been dualoned for a'10.0 pal bottom chord live load nonconcurrent with any other Live loede per Table No. 1641, UBC -07. 5) Load mitts) 7 has /have bean modilied.Building dosigner must review toad:. to verify that they a correct for thu intended use of this truss, 6) Design onsp assum 24x2 (Oat orientation) pudins at oar spacing indiOaled, fastened to truss TC w/ 2 -10d nails. IA warelep- V•dty 4ae15s earaalalu,a •e4 5650 MOTE' ON THIS AND INCLUDED MITER REFERENCE eacC MI ■IFORI Ulf 1 0119.1 van ler no .sy WO WON nM oVCl Mi . YAW c aanou on1i .5011 perimeters shoots, and in 1w an lndM4 budding unopened unope le be Inaallw and blend venially. Appiralexy Al 554511 W l.nl .nlOnl and proper 14(040 6On d aompinem 11 le:pOnuo,IN of ouxd 0111555* • not I114n •$Url.r. 011KM13 JeWa It far 1.11■wIouppdn olMan4IJSI wee mambo oaly. Adddonal emeedary Wenn ie i,.•,r. Mobile. dump nonce ".IMl b le. M1pwnteiler 41e4 erecbl. Addnbnal oonnioald -/.050 al the nelal, •J/L4••• to Os. r..pon.Io■dy of In. alikalni 001155.4. Fen gown* eoldanr• laudoOno leaetanon. oaey tnluW. Names. risers. maaen and 'wham) Lemon OST-is Ouauy alonomo. D3 Si 0•anw] Opotntalu• ...flu nle-el hawing leuaaa0 and tome MnMmo50Ulon av1Yaoe from VLSI Maio 1n:1111w. 513 OOnoni3On... Uaa en, WI 53110 I /dad 3.999 3.389 Me 4x12 = 20.5.12 -0.15 PLATES MI120 20-5-12 5.2.9 Weight; 157 lb Sheathed or 4-10-3 as purtinf, except end vortical', and 0.0.0 oc purlins (10.0.0 max.): A -L Rigid coiling directly applied 01 10.0.0 oc bracing. R10352831 I 0 -o-0 GRIP Cole • 1:341 314 u 0.0.0 1851111 1 0 2-Cin D C r t' �.1 i \ i J —� • ■ `1 1— EXPIRES: 01-24-04 October 9,2003 . 4- ia...:,:ys- :,�:.L;:....0 Ut.t It111I rnua - Oar, 11E4 T NIS NSO Typo I , 009187 � FP01M SL �GFLAT BMC WEstT 1acom0 II LOAD CASEIS) Slbndurd Except: 7) User defined: lumbar Increase =1.15, Plele Incrcwle.1.15 Uniform Lode (p11) Vert: A. Concuntraled Lo Volt: .0, F•K =•20.0 =400.0 N= .100.0 0= -200.0 P= •200.0 0 Winans • Vanry u. Ig11 o0/.01.IM0 psi MCAD NOISE. 00751113 ADO INCLUDED WEEK MIUOUDNCE PAD* I II.7*7a *DOOMS US! now WAN 101 me *Warm WTNk anhl,can. Tma 0.001 001.0 moo u00n panln0 * th0a4. and b foe an IMndual anl/Iny r4/404110111113 00 1171.011 lad Imo*, 041011111O. App14.2011y o1010IIn pN perm 100 Drops 1.16apon1lon of LOmp0Mnt a I..0pn/i11ny ofbu10110 x110o., . 1101 ow, NOsnW, Dosing own M101 II.1a1 1141po11pIM.W011a1w00 41 A0a110nat10npaalyIIII3140 63 46010 sitobilaY &..1O sanwcr.0 I. 1110 I moolosD1ey M 01001.Ua. A00010031pa0al0n0n1 b,ucino of 101 own0 :maw* lila 604060 0113 O0r 0 roaillll Oh.a kes's. wally 03111101, 11aa0.. 0100Iy. mom and uneNO conLUll 01T.a. Naar SWOON. 04O- Ins 'I 6030 11.0 MII.DI MM a0n IMa000 nd aam.aoo M0600 0001111,m on isN .OwnTac &PUl Hooison:Ovr53/111 • ♦JJ JJJ •JJJ 1 11010.0 1 • ow,. goo, 1 •••■ ow' TPIy 2 R10352631 7 Job Reference (optional) '5 b b e Jun 92)03 MheR Intluytrios nc. Wea Oc10e 10:31:20 70b3 Page 2 NOTES 7) Special hangar(.) or oonneclion(s) required to support Conconlrated load(I) 100.01b down at 4.0.0 100.01b down at 6.0.0, and 200.0Ib down at 11.0.0, and 200.0Ib down at 15.4.0 on top chord. Design for unspecified conne01ion(o) is delegated to tho building designer. 0 1 - % • ..-• r� fill - W 6D _JO 0 0 . CO J W O 2 LL <: co_ a x W ; Z � ,. I- O' Z I uj 0 O N ; 0 I— W W LL S. lll V - '. Z VVI LO LUUJ IU1II I I1V111 VII IILVI •VY VVY 9VVV BMC WEST BUILDING MATERIALS Date; 10.29.2003 - South Sound Commercial %' Multi - Family Division Truss Information Fax To: Evergreen Refrigeration; Design & Build Associates Attention: Matt Patton; Frank Nichols Fax Number: 206.763.2389; 360.825.8867 Project: Galliano's Cucina Restaurant From: BMC West Tacoma Commercial Truss Division Number of pages (including coversheet): 4 Matt and Frank, (copy to appropriate Building Official) Enclosed is a copy of the roof truss layout and flat truss supporting mechanical units. Loads have been applied per information provided by Evergreen Refrigeration. Trusses have been designed to carry both units at the same time, although it looks like this condition. will only exist on one truss... Clouded figures and locations on engineering page represent concentrated loads and locations applied to truss. Any questions please feel free'to ei�, r ��� Thank You, i U �� 7 0417.6.A Dale S. Bro n Commerci.I /Multi - Family Projects Director V V V 1• V V I I V V Y 1 V Y V AgONIVED OI1Y OF TUKWILA OCT 3 0 2003 PERMIT CENTER 9721 40 Avenue SW Tacoma, Washington 98499 -4395 Phone: 253.582.1444 Fax: 253.588:4535 Toll Free: 1.800.4BMCWEST OCT 2 9 ?MY.) November 6, 2003 Mike Leahy 727 South Kenyon Street Seattle, WA 98108 RE: Letter of Incomplete Application #1 Development Permit Application Number M03 -182 Galliano's Cucina — 14201 Interurban Avenue South Dear Mike: This letter is to inform you that your application received at the City of Tukwila Permit Center on October 30, 2003, is determined to be incomplete. Before your application can continue the plan review process the following items need to be addressed: Building Department: William Rambo, at 260 431 -3670, if you have questions concerning the following: Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Sincerely, Enclosures City of Tukwila 1. Please provide a roof plan showing all equipment and clearances to each other. (also, see enclosure) .1.---or—e.a... --4,:•aet.C.et— Stefania`Spencer Permit Technician File: Permit File No. M03 -182 Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206.431 -3665 PERMIT COORD COI- r PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M03 -182 DATE: 11 -13 -03 PROJECT NAME: GALLIANO'S CUCINA SITE ADDRESS: 14201 INTERURBAN AVENUE SOUTH Original Plan Submittal X Response to Incomplete Letter # I Response to Correction Letter # Revision # /before permit is issued DEPARTMENTS: Building Dl visio Public Works ❑ Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -18 -03 Complete Documents /routing slIp.doc 2 -28 -02 Incomplete Not Applicable ' Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROyTING: Please Route 21 { Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -16 -03 Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: PERMIT COORD COPY DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Building - Divisio n/ Public Works ❑ PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M03 -182 DATE: 10 -30 -03 PROJECT NAME: GALLIANO'S CUCINA SITE ADDRESS: 14201 INTERURBAN AVENUE SOUTH X Original Plan Submittal Response to Incomplete Letter # _ _ Response to Correction Letter # Revision # /before permit is issued 11 -447 DETERMINATION OF COMPLETENESS: (Tues., Th s.) Complete ❑ TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Comments: Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: rl-4 ' LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Pei Fire ❑ Ping ❑ PW ❑ Staff Initials: •S/GS APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Documents /routing slip.doc 2.28.02 611 ( -a- Fire Prevention Planning Division Structural ❑ Permit Coordinator PERMIT COORD COPY DUE DATE: 11 -04 -03 Not Applicable ❑ DUE DATE: 12 -02 -03 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M03-182 Response to Incomplete Letter # 1 ❑ Response to Correction Letter # to ❑ Revision # after /before Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person GALLIANO'S CUCINA 14201 INTERURBAN AVE SOUTH Phone Number Q06-7-63-1? 1 1-1 Mike Leahy Summary of Revision: 47 c C4Z6Ted r ya � 1450 C CA aca ; o� 0-€ / , n c c 4 t coo f p /... <Q 1ci cc 4 ne C� U c cc,,44k, S (Rat-0 (v, Q ►1 r 5R.0 V i C 2.1yt 'cc is Q 5- A 44.0 4744 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: SAS [ Entered in Sierra on //''3 -03 11/06/03 SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION x 10. DUCT SECTION SLrrL.Y In. kg DUCT SECTION - T Vii In. 7 1 LOA0110 /102 Base Wilt RECTANGULAR DUCT -..� x Iv , 284 131 ROL M DUCT 0 . "...\". 167 19-E LE DUCT 381 VD VCI Lk. DAJr IN 64 374 ZD ZONE DAMPER 145 LOAl20 Base Unit MD MOTTORQED DAMPER 300 136 FD FIRE DAMPER 364 MP FRE/'SMO E PALM QZOV PO1'ER KEW 344 - ' 352 G54.616 RADIATION DAMPER 0 50 SMOKE DETECTOR 0 T TrERMO'STAT 152 S SENSOR ----- R-------- R KEFRIMEANT LIES ---- -- R---- --- LOAIS0 Max. Unit 6 NATURAL WS LP ' S , 364 11 348 021.6,6 or UNN WAVY) 450 204 IIE UST) ii By EXHAUST FAN (Cd.1+16 AAOLIVTED) r �j mire rAN PR�c'J!'ELLER FAN aka I , 'hOE'WM4 DI'rL 1JV• /; �••: MGT Fr TMN6 00.4. a 2' -.•'. DATUM UNIT TAG • OW RISER MODEL AA IS cc DO 10. kg In. kg In. k, In. k! LOA0110 /102 Base Wilt 314 142 , 284 131 52q , 149 366 167 LQAON /10! Max. Unit 381 173 339 64 374 170 411 145 LOAl20 Base Unit 328 r 144 300 136 343 l56 364 174 LOAl20 Max. Unit 344 174 352 KO 367 176 447 203 LOA160 Bast Unit I 3% 152 312 152 4 553 KO 389 04 LOAIS0 Max. Unit 403 153 , 364 145 348 Id 450 204 MODEL EE FF in as in on LOA0110 /10:: seam Unit 47 N44 ZH/2 546 LOA0110 /102 Max. Unit 44 868 23 547 LOAl20 Base Unit 47 1q4 zi-1/2 546 LOAl20 Mau. Unit 44 r:8 23 547 LOA160 Bale Unit 47 1207 22 559 LOA160 Max. Unit 46 Iii 24 `IO MODEL EE 1 FF in se in an 00810.024 F • M J 00811 - 030 26-1/2 724 19-3/4 502 OC811 -o3s 24-5/6 20-4/ 4 -- 00811.041 33-1/2 851 22 559 00811 -000 34-1/2 676 23 584 a r r 1460.11t S 1 50th 6t . tb RTU I RTU 2 Jo Mem memorial P4rkL IS • SCALE : N.T.I. { $134th 1 r ~ 4I I pr ngsiPa►r. VICINITY PLAN MARK MANF. LENNOX LENNOX t1tst ti S' N S Zs T kwll� � I ltaitelnut,Plrk I I s14Pthlst rn us 1500 0 1 y S 152.nd 6I _. S 1 52nd P -300/1 MODEL L6AO90S -I30 6GS16- 030 -75 NOTES: I. THE ROOFTOP UNIT GOD'S COMPLETE WITH A SMOKE DETECTOR N TFf MAN SUPIP'l.Y DUCT N ACCORDANCE WITH UMC SEC. 508. 2. THE ROOFTOP LINT COMES COMPLETE WITH AN ECONOMIZER N ACCORDANCE WITH THE WSEG SF_G. 1423. 3. THE ROOFTOP UNIT GONE COMPLETE WITH AN O UTSCOE AR HOOD. AN ECONOMIZER 15 NOT REQUIRED N ACCORDANCE WITH THE WSEG 1423. 4. THE ROOFTOP LINT GOMES COMPLETE WITH POWER EXHAl15T. 5. THE ROOFTOP [ VT V17TH A STAN -Er- 5TEa. FEAT EXCHANGER. DD OUTDOCR AT HOOP or MIA Mt TONS. T 7.5 2.5 • TENDS • Ewa • . Ttskw BACK VIEW 561473). UIFT SIDE SIDS VW 1 . 1 - 1 .4; lf d 44 4 4 /1St. 3 I43rd Q s 151st >t I g 1s1st PI ss AIRFLO SP CFM INS CFM 3000 10 4'.4 • . • .. • •o r MOTOR TOP VIEW 94-v4 (252D • )1 \ Fort Dent ' `'4, • J 0.G• 0.35' GCND GOL so �X b, • K COtg MIN. OSA CC 600 200 T M ) 4540) �3i/403) t • • GAS PACKAGE EQUIPMENT SCHEDULE a 2.V.e C N DAMER WAKE RETURN AR AR Or'E1(6 W PO EK Mt 8' Q27 x 205 ma RTU 1 MOTOR HP 2 I/2 I1%L.ATION DRIVE . FRONT VIEW 4.5-3/8(2423). 9- 3/4M PRAME RETURN AIR #1 D.D. TOP VIEW (Balm S•otlon) i / BTUH 27,400 4 C2521-- YI►.A C 6 AR I 1OP VIEW TOTAL 93,000 EASE DOTTOM 1 rbDE PAI'E1. ' V viir COUNTER MO LJIYT'INb Mae w! 1 . CANT STRIP '0M« Wiggt TYP O PLA a1Mls OSTINL MARK Er -I Er -t EF -3 EF -4 COOLING SEER EER aft 10.0 CENTER OF OAAVITY- ti ---28 c7o ---- + ‘DOTTOM Y AR 4Ma ir SECTION A -A MANP. /MODEL 166 - UDGA -I6 M.6 - GRDGA -106 MOAN - 1450 DROAN - L250 A 10.3 8.7 - H5/16(46) INPUT BTUH 125,000 75,000 BY Date Permit N EXHAUST FAN SCHEDULE aPw I SP 3'!00 700 240 240 HEATING OUTPUT BTUH 104,000 40,000 1 understand that the Ran solliect to errc*s and plans does not authorize t `adopted code or ordinance tractor's copy of approved • 0.5' 0 .4' 0.373' 0.375' II -II rE..? 31105 PAC CI "ANC - 3 BE WOE 10 1 PRIOR 1 SCCPE ' • , ti ° GNP �.; CF ,,.. , , . ,_A a k)I NG /�, r_ , � �' \�V1��. � � . , , . � � N .N p+,A�l 111J0Of'1'TI P!�TE REVISIONS Mn��p ,....� t - � �.�.3 t" "1 ...t,t, . ho.-4 . FILE C / t3 AFUE (%) 60 60 SEPARATE PER IT REQUIRED FO ❑ MECHANICAL E LECTRICAL [PLUMBING VGAS PIPING CITY OF TUKWI BUILDING DIVISI N • HP /AMP PY 1/4 2.2 A 2.2 A EF - 3,4 VOLTS (V) 208 -230 206 -230 POWER M"v /10 P3V /I0 15v/10 ELECTRICAL PHASE 30 10 CENTER OF GRAVITY. heck approvals are ns and approval of violation of any . Receipt of con - ans acknowledged 1-0/16(46) - T H5/16(4ii 0 FRAME RETURN OMENA e time Tyro I lieu, Roof Mounted) tome Type I Dion Hsu, Roof Mwntii torus Mono Row**, GoilinO Mounted Servo 6 5u1bflit to y •f ha.Lm#1re. b p i i �"°ra at I. �41Mm *ter 4 k polprpied Wi414 4111140# 440 4414 kudsmi 3. Inla lKi. buFH hail gchuafs f► make-Up Air '.pers. IF MWs •kf !:r f3 olrhawy N OwFtuk, lir d&Nef Mash Dptn -W ProviAt abiftiraA wtics• M.C.A. (A) 44 r � 61 E MO OPN ■ SLIFFLY orews 5/6 20 ,• •'41, r. 0 20-V2 <521 MAX FUSE (A) 50 TOP VIEW BASE SECTION FRAME TOP VIEW OURS REMARK Wade, Carlin Mounted 30 dM In..Y AIR OP deb UNIT DIMENSION Fier 8 24-VV H UNIT LBS 1300 A 373 - •' 115/1(46) A MODEL GCS 00815 -024 OC81 /•030 OCSIS -04111 OC81s -04S GC81s -oS0 TON 2 2.5 3 4 6 UNIT DIMENSION (INCHES) A 46 52 B 60 72-1/2 C 23 29 D b 22 E 13 16 F D 22 0 I0 7-1/2 3 5 J 4 3 3-1/6 4-1/8 L 4-I/8 6-1/8 M 2 5 5 6 R 4 3/4 PWR.EX. LBS 28 H3A6 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS Rem% DRAWINGS OP THE ACTUAL INSTALLATION SHALL DE PIQYIPED TO THE OWNER WITHIN 40 DAYS OP THE PATE OP SYSTEM ACCEPTANCE PER If A'ShVN6TON STATE ENER6Y GODS (SSEG) 'SECTION 14161 AN OPERATING MANUAL AND MAINTENANCE MANUAL. 'SHALL DE PROVIDED TO THE OUILDING OWNER PER WSEG 'SECTION 1416.2. ALL HVAG SYSTEM'S SHALL OE DALANGEP AND A WRITTEN DALANGE REPORT 'SHALL pE PROVIDED TO THE OWNER PER Wtmm 'SECTION 14161 .y HVA GONT OL S SHALL .. ., •, G • 0 AND ADJUSTED, 'SEQUENCES OP OPERATION 'SHALL DE TESTED TO ENSURE THAT THEY OPERATE N ACCORD WITH 'SPEGV%ATION'S AND APPROVED PLAN'S, AND A GOMnLETE REPORT Or TEST PROCEDURES AND RESULTS SHALL DE PILED WITH THE OWNER PER WSEG 'SECTION 1416.4i rER /LL QT R SY' T : HVAG CONTROL SYSTEMS SHALL DE TESTED, GAL.IDRATED ACV AOJJ'ST 'SEQUENCE'S OP OPERATION 'SHALL DE TESTED TO EN'SURE THAT THEY OPERATE N ACCORD WITH 'SPECIFICATIONS AND APPROVED PLAN'S PER THE WSEG SECTION 1416.4.2; NECE'S'SARY TESTS SHALL DE OENTrED PER WSEG 'SECTION 1416.4.21 % .� .. Jr.i :7 i :� ` +: i �' 7T:'�- +'.� «': ► l"�.: a �'.�'�T` t . 4' /r,TT `.'� "� i • =� L ;•tom -`. -frh • AND A GObPLETE FINAL GObNAi'S'SION1146 RETORT PROCEDURE'S AND RE5IJL.T5 SHALL. DE PILED WITH THE OWNER PER WSEG 'SECTION 1416.4.2.2.1 LT air Volst,ht,e. 7 WEIGHT ECONO LBS 66 4111* 411•0 IMO .. ..} . 17 1 1117 4A DIL OUTDOOR AR PAMPER WIELD INSTALLED) OUTLET\L CURB DIMENSION MAN. OSA LBS 12 CURB Standard 126 75 6AS N- r A CONTROL DOX HORIZONTAL SUITLY AR RETURN AR '-51(46)- 1625) 2511 51567 AN A-A SACK VIEW RTU 2 TOP VIEW TOTAL LBS 520 460 GoM a ,eR GOL INTAKE AR .ti OrTIONAL s M N INb SIDE VIEW CURS FLTER SIZES NO. (LxWxD) 1 NO 68'x24'x2') 1 NO. (16'x25'xl') NAILER STRIP SOUND REDUCTION I ROOrt CURD roves ENTRY 0 0TH (7/8') TYPICAL PLASHING POR 11111,111 NOW MOUNTING PRAM, NOTES 1,2,4,5 1,3 GENERAL NOTES °U LIMN K LI • • ♦ w ALL DUCT D�NSIONNS ON PLAN ARE GL.EAR "Ave DNAEN'SION'S p 2' TO EACH DIMENSION T OOTAN OUTSIDE ADO 410 EACH Ap r DUCTWORK It ON THE EXTERIOR OP DiALON6. 1.2 THE PIRST NukeeR ON ALL DUCT DIMEN'SION'S IS THE WIDTH AND THE SECOND NUMDER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PL.EMJMA'S SHALL HAVE A PLATE 'SPREAD RATN6 LESS THAN 29 AND A PLAIIAE 'AAOKE DEVELOPMENT RATING LESS THAN 50, PER UMG 1447, WSEG.601.4. 1.4 SEAL ALL. TRANSVERSE JOINTS POR DUCTWORK WITH ''STATIC PRESSURE OETWEEN 1/2 INCISES AND 2 ACHE'S. DUCTWORK WHICH IS OE'SkifED TO OPERATE AT PRESSURE'S ADOVE I/2 INCH WATER COLUMN 'STATIC PRES% *f SHALL SE 'SEALED N ACCORDANCE WITH STANDARD RS-I6. 1.5 ALL DUCT 6AIXiES PER TADLE 6 -A M TADLE 6 -15 OP 1447 SIG. 1.6 ALL DUCT SUPPORT'S PER TADLE 4 -E OP 1447 UMG. 1.7 ATTACH PIPPLM:ER5 AND GRILLES TO T -DAR GRID PER GODES. 1.6 iDALANGINO DAI►rER5 ARE TO DE INSTALLED ON ALL DRANGH DUCTS OR orrutERS. VUQT INSULATIQJI 2.1 INSULATE OR LltE DUCTWORK PER WSEG EM MY AND MECHANICAL. GODES. GINERAL comp 3.1 SEW/CAL. GONT''ACTOR TO PROVIDE AND GUT OPENN6S FOR ALL ROOFTOP, GEM..N6, FLOOR, AND WALL PENETRATIONS, INGLUDN6 WEATHERPROOF SEALING AND FIRE PROOF LINNIN6 PER S.M.G. 3.2 GENERAL GONT ACTOR TO VERIFY PENETRATION LOCATION AND DIMENSION'S WITH ERI wrote FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 6ENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUrPORT AS REQURED FOR MECHANICAL WORK. 3.5 6ENERAL GONT :'ACTOR TO PROVIDE ADEQUATE EN6INEERIN6 AS REQUIRED FOR MECHANICAL WC K. 3.6 6ENERAL GONT!'AGTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUrMENT. 3.7 GENERAL GONTI :ACTOR TO LEVEL ALL FACTORY CURDS PROVIDED DY ERN, PROVIDE ALL CANT 5TRi.'S AND CURD INSULATION, AND SEAL A6AINST LEAKS. 3.8 GENERAL GONT ` AGTOR TO PROVrf ALL GUTTN6 AND PATCHING OF T CEILING AS REQUIRED FOR HVAG INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL. OPENIN65 THROU6H FLOORS PROVIDED FOR DUCTWORK N'S1 ALLATION N ACCORDANCE WITH TADLE 6A OF UNIFORM DIJN.DIN6 CODE (1447 EDIT'ON), WHERE REQUIRED DY SECTION 71 OF UDC 0447). 5LECTRICAL 4J ERI TO INSTALL ALL LOW VOLTAGE CONTROL WRING, CONDUIT WILL. DE PROVIDED DY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO FROVIDE ALL ELECTRICAL CONVECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL. EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERI MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL. CONTRACTOR TO INTERLOCK DATHROOM EXHAUST FANS WITH L16HT SWITCH. 4.5 ERI TO PROVIDE 7 -DAY NIGHT SETDAGK, PROGRAM MADLE TYPE T -STAT WITH GAPADL.ITY OF 5'F DEADDAND. 4.6 ERI TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. PLUMBING 5J PLUMDN6 GENT :ACTOR TO FURNISH AND INSTALL ALL 6A5 PrN6 FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMDIN6 CONTRACTOR OFFSET VENTS 10 FEET AANMJM FROM ALL HVAG FRESH AIR INTAKES OR 3' ADOVE 46IE5T POINT OF INTAKE. 5.3 CONDENSATE MAINS AND DRAIN LINES DY ERN., DRAIN TO ROOF WITHIN 12' OF UNITS. INEnelY ODE CC,MPLIMICE 6.1 AT A IAA, EACH FLOOR IS TO DE CONSIDERED A SEPERATE ZONE. VERPY THERMOSTATIC ' CONTROL. FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL DE EQUPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEG. 1412.41 6.3 AIR ECONOWAS 3 WHERE REQUIRED DY CODE ARE INDICATED DY THE EQUIPMENT SCHEDULE AT Wax GAPADLITY, CONTROL AND OPERATION OF THE EGONOMISER SHALL COMPLY "". - H WSEG SEC. 1423. MECHANICAL GOD OMPLIANCB 7., WHERE MUM') PROVIDE AUTOMATIC SHUTOFF ACTIVATED DY SMOKE DETECTORS N EACH SYSTe.14 DELIVERING hEATN6 OR GOOLN6 AIR N EXCESS OF 2000 CFM. DETECTORS SHALL DE LOCATED N THE MAIN SUPPLY AMR PER UMG 1447 SEC. 60& w ww+,.r,,. - . .■••••• w.•.ww+■�I+ -.�wM w Tee+. - ... S cc LL. w w ac z w w ce 0 w w NO O u. • 1 tc d 0 I REVISIONS DATE *TV OR TUKWILA CT 30 201 3 purr CiFt llp DRAWING DATE: DWG. BY: BY: JOB NO DWG. FILE: M 1 0 4 4 0 0 GIN GIALLIAMI 0:1 co CC c• OURS DIMENSION (MOMS) MODEL A • C 0 • F • M J K New18.41 % -5/6 92 -5/4 44-7/8 41-1/4 24-5/6 20-4/ 4 -- 22-5/16 4-1/2 RMP1S M 15 ,O-1✓2 46-7/0 24-1/4 20.1/2 4 4 17 9 a r r 1460.11t S 1 50th 6t . tb RTU I RTU 2 Jo Mem memorial P4rkL IS • SCALE : N.T.I. { $134th 1 r ~ 4I I pr ngsiPa►r. VICINITY PLAN MARK MANF. LENNOX LENNOX t1tst ti S' N S Zs T kwll� � I ltaitelnut,Plrk I I s14Pthlst rn us 1500 0 1 y S 152.nd 6I _. S 1 52nd P -300/1 MODEL L6AO90S -I30 6GS16- 030 -75 NOTES: I. THE ROOFTOP UNIT GOD'S COMPLETE WITH A SMOKE DETECTOR N TFf MAN SUPIP'l.Y DUCT N ACCORDANCE WITH UMC SEC. 508. 2. THE ROOFTOP LINT COMES COMPLETE WITH AN ECONOMIZER N ACCORDANCE WITH THE WSEG SF_G. 1423. 3. THE ROOFTOP UNIT GONE COMPLETE WITH AN O UTSCOE AR HOOD. AN ECONOMIZER 15 NOT REQUIRED N ACCORDANCE WITH THE WSEG 1423. 4. THE ROOFTOP LINT GOMES COMPLETE WITH POWER EXHAl15T. 5. THE ROOFTOP [ VT V17TH A STAN -Er- 5TEa. FEAT EXCHANGER. DD OUTDOCR AT HOOP or MIA Mt TONS. T 7.5 2.5 • TENDS • Ewa • . Ttskw BACK VIEW 561473). UIFT SIDE SIDS VW 1 . 1 - 1 .4; lf d 44 4 4 /1St. 3 I43rd Q s 151st >t I g 1s1st PI ss AIRFLO SP CFM INS CFM 3000 10 4'.4 • . • .. • •o r MOTOR TOP VIEW 94-v4 (252D • )1 \ Fort Dent ' `'4, • J 0.G• 0.35' GCND GOL so �X b, • K COtg MIN. OSA CC 600 200 T M ) 4540) �3i/403) t • • GAS PACKAGE EQUIPMENT SCHEDULE a 2.V.e C N DAMER WAKE RETURN AR AR Or'E1(6 W PO EK Mt 8' Q27 x 205 ma RTU 1 MOTOR HP 2 I/2 I1%L.ATION DRIVE . FRONT VIEW 4.5-3/8(2423). 9- 3/4M PRAME RETURN AIR #1 D.D. TOP VIEW (Balm S•otlon) i / BTUH 27,400 4 C2521-- YI►.A C 6 AR I 1OP VIEW TOTAL 93,000 EASE DOTTOM 1 rbDE PAI'E1. ' V viir COUNTER MO LJIYT'INb Mae w! 1 . CANT STRIP '0M« Wiggt TYP O PLA a1Mls OSTINL MARK Er -I Er -t EF -3 EF -4 COOLING SEER EER aft 10.0 CENTER OF OAAVITY- ti ---28 c7o ---- + ‘DOTTOM Y AR 4Ma ir SECTION A -A MANP. /MODEL 166 - UDGA -I6 M.6 - GRDGA -106 MOAN - 1450 DROAN - L250 A 10.3 8.7 - H5/16(46) INPUT BTUH 125,000 75,000 BY Date Permit N EXHAUST FAN SCHEDULE aPw I SP 3'!00 700 240 240 HEATING OUTPUT BTUH 104,000 40,000 1 understand that the Ran solliect to errc*s and plans does not authorize t `adopted code or ordinance tractor's copy of approved • 0.5' 0 .4' 0.373' 0.375' II -II rE..? 31105 PAC CI "ANC - 3 BE WOE 10 1 PRIOR 1 SCCPE ' • , ti ° GNP �.; CF ,,.. , , . ,_A a k)I NG /�, r_ , � �' \�V1��. � � . , , . � � N .N p+,A�l 111J0Of'1'TI P!�TE REVISIONS Mn��p ,....� t - � �.�.3 t" "1 ...t,t, . ho.-4 . FILE C / t3 AFUE (%) 60 60 SEPARATE PER IT REQUIRED FO ❑ MECHANICAL E LECTRICAL [PLUMBING VGAS PIPING CITY OF TUKWI BUILDING DIVISI N • HP /AMP PY 1/4 2.2 A 2.2 A EF - 3,4 VOLTS (V) 208 -230 206 -230 POWER M"v /10 P3V /I0 15v/10 ELECTRICAL PHASE 30 10 CENTER OF GRAVITY. heck approvals are ns and approval of violation of any . Receipt of con - ans acknowledged 1-0/16(46) - T H5/16(4ii 0 FRAME RETURN OMENA e time Tyro I lieu, Roof Mounted) tome Type I Dion Hsu, Roof Mwntii torus Mono Row**, GoilinO Mounted Servo 6 5u1bflit to y •f ha.Lm#1re. b p i i �"°ra at I. �41Mm *ter 4 k polprpied Wi414 4111140# 440 4414 kudsmi 3. Inla lKi. buFH hail gchuafs f► make-Up Air '.pers. IF MWs •kf !:r f3 olrhawy N OwFtuk, lir d&Nef Mash Dptn -W ProviAt abiftiraA wtics• M.C.A. (A) 44 r � 61 E MO OPN ■ SLIFFLY orews 5/6 20 ,• •'41, r. 0 20-V2 <521 MAX FUSE (A) 50 TOP VIEW BASE SECTION FRAME TOP VIEW OURS REMARK Wade, Carlin Mounted 30 dM In..Y AIR OP deb UNIT DIMENSION Fier 8 24-VV H UNIT LBS 1300 A 373 - •' 115/1(46) A MODEL GCS 00815 -024 OC81 /•030 OCSIS -04111 OC81s -04S GC81s -oS0 TON 2 2.5 3 4 6 UNIT DIMENSION (INCHES) A 46 52 B 60 72-1/2 C 23 29 D b 22 E 13 16 F D 22 0 I0 7-1/2 3 5 J 4 3 3-1/6 4-1/8 L 4-I/8 6-1/8 M 2 5 5 6 R 4 3/4 PWR.EX. LBS 28 H3A6 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS Rem% DRAWINGS OP THE ACTUAL INSTALLATION SHALL DE PIQYIPED TO THE OWNER WITHIN 40 DAYS OP THE PATE OP SYSTEM ACCEPTANCE PER If A'ShVN6TON STATE ENER6Y GODS (SSEG) 'SECTION 14161 AN OPERATING MANUAL AND MAINTENANCE MANUAL. 'SHALL DE PROVIDED TO THE OUILDING OWNER PER WSEG 'SECTION 1416.2. ALL HVAG SYSTEM'S SHALL OE DALANGEP AND A WRITTEN DALANGE REPORT 'SHALL pE PROVIDED TO THE OWNER PER Wtmm 'SECTION 14161 .y HVA GONT OL S SHALL .. ., •, G • 0 AND ADJUSTED, 'SEQUENCES OP OPERATION 'SHALL DE TESTED TO ENSURE THAT THEY OPERATE N ACCORD WITH 'SPEGV%ATION'S AND APPROVED PLAN'S, AND A GOMnLETE REPORT Or TEST PROCEDURES AND RESULTS SHALL DE PILED WITH THE OWNER PER WSEG 'SECTION 1416.4i rER /LL QT R SY' T : HVAG CONTROL SYSTEMS SHALL DE TESTED, GAL.IDRATED ACV AOJJ'ST 'SEQUENCE'S OP OPERATION 'SHALL DE TESTED TO EN'SURE THAT THEY OPERATE N ACCORD WITH 'SPECIFICATIONS AND APPROVED PLAN'S PER THE WSEG SECTION 1416.4.2; NECE'S'SARY TESTS SHALL DE OENTrED PER WSEG 'SECTION 1416.4.21 % .� .. Jr.i :7 i :� ` +: i �' 7T:'�- +'.� «': ► l"�.: a �'.�'�T` t . 4' /r,TT `.'� "� i • =� L ;•tom -`. -frh • AND A GObPLETE FINAL GObNAi'S'SION1146 RETORT PROCEDURE'S AND RE5IJL.T5 SHALL. DE PILED WITH THE OWNER PER WSEG 'SECTION 1416.4.2.2.1 LT air Volst,ht,e. 7 WEIGHT ECONO LBS 66 4111* 411•0 IMO .. ..} . 17 1 1117 4A DIL OUTDOOR AR PAMPER WIELD INSTALLED) OUTLET\L CURB DIMENSION MAN. OSA LBS 12 CURB Standard 126 75 6AS N- r A CONTROL DOX HORIZONTAL SUITLY AR RETURN AR '-51(46)- 1625) 2511 51567 AN A-A SACK VIEW RTU 2 TOP VIEW TOTAL LBS 520 460 GoM a ,eR GOL INTAKE AR .ti OrTIONAL s M N INb SIDE VIEW CURS FLTER SIZES NO. (LxWxD) 1 NO 68'x24'x2') 1 NO. (16'x25'xl') NAILER STRIP SOUND REDUCTION I ROOrt CURD roves ENTRY 0 0TH (7/8') TYPICAL PLASHING POR 11111,111 NOW MOUNTING PRAM, NOTES 1,2,4,5 1,3 GENERAL NOTES °U LIMN K LI • • ♦ w ALL DUCT D�NSIONNS ON PLAN ARE GL.EAR "Ave DNAEN'SION'S p 2' TO EACH DIMENSION T OOTAN OUTSIDE ADO 410 EACH Ap r DUCTWORK It ON THE EXTERIOR OP DiALON6. 1.2 THE PIRST NukeeR ON ALL DUCT DIMEN'SION'S IS THE WIDTH AND THE SECOND NUMDER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PL.EMJMA'S SHALL HAVE A PLATE 'SPREAD RATN6 LESS THAN 29 AND A PLAIIAE 'AAOKE DEVELOPMENT RATING LESS THAN 50, PER UMG 1447, WSEG.601.4. 1.4 SEAL ALL. TRANSVERSE JOINTS POR DUCTWORK WITH ''STATIC PRESSURE OETWEEN 1/2 INCISES AND 2 ACHE'S. DUCTWORK WHICH IS OE'SkifED TO OPERATE AT PRESSURE'S ADOVE I/2 INCH WATER COLUMN 'STATIC PRES% *f SHALL SE 'SEALED N ACCORDANCE WITH STANDARD RS-I6. 1.5 ALL DUCT 6AIXiES PER TADLE 6 -A M TADLE 6 -15 OP 1447 SIG. 1.6 ALL DUCT SUPPORT'S PER TADLE 4 -E OP 1447 UMG. 1.7 ATTACH PIPPLM:ER5 AND GRILLES TO T -DAR GRID PER GODES. 1.6 iDALANGINO DAI►rER5 ARE TO DE INSTALLED ON ALL DRANGH DUCTS OR orrutERS. VUQT INSULATIQJI 2.1 INSULATE OR LltE DUCTWORK PER WSEG EM MY AND MECHANICAL. GODES. GINERAL comp 3.1 SEW/CAL. GONT''ACTOR TO PROVIDE AND GUT OPENN6S FOR ALL ROOFTOP, GEM..N6, FLOOR, AND WALL PENETRATIONS, INGLUDN6 WEATHERPROOF SEALING AND FIRE PROOF LINNIN6 PER S.M.G. 3.2 GENERAL GONT ACTOR TO VERIFY PENETRATION LOCATION AND DIMENSION'S WITH ERI wrote FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 6ENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUrPORT AS REQURED FOR MECHANICAL WORK. 3.5 6ENERAL GONT :'ACTOR TO PROVIDE ADEQUATE EN6INEERIN6 AS REQUIRED FOR MECHANICAL WC K. 3.6 6ENERAL GONT!'AGTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUrMENT. 3.7 GENERAL GONTI :ACTOR TO LEVEL ALL FACTORY CURDS PROVIDED DY ERN, PROVIDE ALL CANT 5TRi.'S AND CURD INSULATION, AND SEAL A6AINST LEAKS. 3.8 GENERAL GONT ` AGTOR TO PROVrf ALL GUTTN6 AND PATCHING OF T CEILING AS REQUIRED FOR HVAG INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL. OPENIN65 THROU6H FLOORS PROVIDED FOR DUCTWORK N'S1 ALLATION N ACCORDANCE WITH TADLE 6A OF UNIFORM DIJN.DIN6 CODE (1447 EDIT'ON), WHERE REQUIRED DY SECTION 71 OF UDC 0447). 5LECTRICAL 4J ERI TO INSTALL ALL LOW VOLTAGE CONTROL WRING, CONDUIT WILL. DE PROVIDED DY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO FROVIDE ALL ELECTRICAL CONVECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL. EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERI MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL. CONTRACTOR TO INTERLOCK DATHROOM EXHAUST FANS WITH L16HT SWITCH. 4.5 ERI TO PROVIDE 7 -DAY NIGHT SETDAGK, PROGRAM MADLE TYPE T -STAT WITH GAPADL.ITY OF 5'F DEADDAND. 4.6 ERI TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. PLUMBING 5J PLUMDN6 GENT :ACTOR TO FURNISH AND INSTALL ALL 6A5 PrN6 FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMDIN6 CONTRACTOR OFFSET VENTS 10 FEET AANMJM FROM ALL HVAG FRESH AIR INTAKES OR 3' ADOVE 46IE5T POINT OF INTAKE. 5.3 CONDENSATE MAINS AND DRAIN LINES DY ERN., DRAIN TO ROOF WITHIN 12' OF UNITS. INEnelY ODE CC,MPLIMICE 6.1 AT A IAA, EACH FLOOR IS TO DE CONSIDERED A SEPERATE ZONE. VERPY THERMOSTATIC ' CONTROL. FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL DE EQUPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEG. 1412.41 6.3 AIR ECONOWAS 3 WHERE REQUIRED DY CODE ARE INDICATED DY THE EQUIPMENT SCHEDULE AT Wax GAPADLITY, CONTROL AND OPERATION OF THE EGONOMISER SHALL COMPLY "". - H WSEG SEC. 1423. MECHANICAL GOD OMPLIANCB 7., WHERE MUM') PROVIDE AUTOMATIC SHUTOFF ACTIVATED DY SMOKE DETECTORS N EACH SYSTe.14 DELIVERING hEATN6 OR GOOLN6 AIR N EXCESS OF 2000 CFM. DETECTORS SHALL DE LOCATED N THE MAIN SUPPLY AMR PER UMG 1447 SEC. 60& w ww+,.r,,. - . .■••••• w.•.ww+■�I+ -.�wM w Tee+. - ... S cc LL. w w ac z w w ce 0 w w NO O u. • 1 tc d 0 I REVISIONS DATE *TV OR TUKWILA CT 30 201 3 purr CiFt llp DRAWING DATE: DWG. BY: BY: JOB NO DWG. FILE: M 1 0 4 4 0 0 GIN GIALLIAMI 0:1 co CC c• 0 120 imprm 8' SCALE : 114 • ?-0' • i HVAC PLAN a 250 CFM (TYP 4) 16' 7 1/2 TON 22' PEAL —! 120 • ,� SCALE : 114' • 1 KEYNOTES: O TYPE I KITCHEN HOOD TO BE PROVIDED BY O'FER9 (9EPERATE PERMIT) 2O DUCT MOUNTED POWER EXHAViT. HVAC ROOF PLAN (CLEARANCES) 0SA SEPERATION RTU I EF4 SEPERATION • 0`2A SEPERATION RTU 2 CIP* NO 1 3 2003 INCOMPLETE LTR #. S