Loading...
HomeMy WebLinkAboutPermit M03-213 - CLAUSEN RESIDENCEClausen Residence 4402 S 164 St EXPIRED 11 -11 -05 M03 -213 z Z oo U)0. W= • J � CO hi. .. • • 'W o. IL , :0 W = - O: Z. • li.l U =. City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 5379800600 Address: 4402 S 164 ST TUKW Suite No: Tenant: Name: CLAUSEN RESIDENCE Address: 4402 S 164 ST, TUKWILA WA Owner: Name: MICHAEL CLAUSEN Address: 4402 S 164TH ST, TUKWILA WA Contact Person: Name: MICHAEL CLAUSEN Address: 4402 S 164 ST, TUKWILA WA Contractor: Name: BROOKS DESIGN & BUILD Phone: Address: 4050 W LK SAMMAMISH PY NE #107, REDMOND WA Contractor License No: BROOKD981J3 Expiration Date:04 /05/2004 DESCRIPTION OF WORK: REPLACE EXISTING FURNACE WITH NEW FORCED AIR GAS FURNACE. Value of Construction: $3,000.00 Type of Fire Protection: AFA Permit Center Authorized Signature: l�Qi Signature: Print Name: A4( doc: Mech MECHANICAL PERMIT M03 -213 z Permit Number: M03 -213 a z Issue Date: 01/22/2004 e: 2 Permit Expires On: 07/20/2004 6 v 00 0 0 Fees Collected: Uniform Mechnical Code Edition: Phone: Phone: 206 248 -1024 $65.00 1997 . Date: / I hereby certify that I have read and examined tiffs permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this per it does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio the performance of work. I am authorized to sign and obtain this mechanical permit. Date: / - 22- 0 `1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 01 -22 -2004 i •i.i.wa�'W:+.x�. u:.l..r.'7.i: W W LL w 2 = w z F— O z ►- w w 0 O � 0 F- W u Z 0~ Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 5379800600 Address: 4402 S 164 ST TUKW Suite No: Tenant: CLAUSEN RESIDENCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 7: Manufacturers installation instructions required on site for the building inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions ficLR -2 PERMIT CONDITIONS M03 -213 Permit Number: M03 -213 Status: ISSUED Applied Date: 12/15/2003 Issue Date: 01/22/2004 Date: 1 -7 2 ' ° Printed: 01 -22 -2004 :n._.,, ._ f.� v.. ru:,_ v _ .... ,.._..,,,..., _ _ .._r _ _.. Site Address: LI 4 0 •L Tenant Name: Property Owners Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100. Tukwila, WA 98188 Mailing Address: HIV 0 .Z Name: ? N;c\.o. ( c\ ���,� Company Name:. 'Y..cooK s Mailing Address: E -Mail Address: Mailing Address: Contact Person: 6= it Contact Person: E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** s . J h`l St s. I404 aC 5� Mailing Address: by :> c. ( lag 4 E -Mail Address: b.' Contact Person: — 5 - 95 0',s. 1, r J'OICs co, 4,1 ,/ Stl ov. Company Name: i y a k s ,4 }ti aoKS (ay. - . nPt E -Mail Address: Suite Number: New Tenant: I JYw,` °\ City King Co Assessor's Tax No.: — 0 b a u - 0 9 \r State Day Telephone: City Fax Number: w � State Floor: 2_. .... Yes [ No Zip X188) Zip .Ta ; i . !•��? ; 4:JV. I. f �r.TS t �1{.� ?.C.t i4"n f , �'a 1 State 490 Zip 3S City Day Telephone: (42 Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** • - • t Kt ' 4 �: fi • lil 1 ' } tri 'it..•y l...•tc :i"' 1 i'3i :...'••ti.tft.r•. :CO :.All: lams: ust betivetsta eb bri r d decnitectorReco •e •r'+F') tA' f'•. .'•ily'hi; yr'X f -S j d ti :�•�i ,rw•l�ati.". "' s'! i 4 i'. F" w t:(� I?. tt ..:, : :' ;�. I ,, i:, : r, , `t •mo . i �c � : r` f t (1 i4 a t j "r. r, r�, -. 'L!•: +r N7: _ ry.'Yt.,:4 « rJ ';Y.. 5�".: , :'.'�:.i. >.: ..... .. a'.y i::a. •:. City State Zip Day Telephone: '-I2 03 12 g o Fax Number: y 2 r ir3 ►2`l0 Rs ; R;E i , ; . •:� ~� , . ,:.,. .. ... r. Q )fan M pst,pe:,�iiet.sr� mpeya;b" Eiiigig`e r of ' d ' 4I; !: t: x �. . . +7 1'w' : l' •: :'� • T• FENGINEE - , uo r ...a ....:..... .n• , .. ...r.. d*+�s :., r:.1 .. 1.>•'t.: S. "a. u..r a ).a��'. -: .::'J, }4 '` .� . r. i 1 .S•... ,�._'r. ..,❖). Company Name: Mailing Address: State Zip City Day Telephone: Fax Number: ?i nisi ±r .Lcit,' 2)411ti.::erki ` 410. ,3tir Unit Type:, . 'Qty Unit Type: • ;: : Qty .Unit•Type _ *_• ;r-;': . -Qty : Boiler /Compressor .. Qty ',; Furnace <100K BTU J Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit < =10,000 CFM Incinerator — Comm/Ind 4 • i �' { i., !. . i1 .s.4 ftlirt. NSF }.��.' ;'f;"•,yT.ce's4 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: - aa2eio. Qt—t irer-t7 Indicate type of mechanical work being installed and the quantity below: Print Name: PIN: c ‘" at' Mailing Address: 6�1 5 �' City Day Telephone: Fax Number: City State Zip Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 3 000 Scope of Work (please provide detailed ig Use: Residential: New ....❑ Replacement ....' Commercial: New .... EI Replacement ....ID Fuel Type: Electric 0 Gas...' Other: t is ble o'a rin>< i t t: do i�-�� �A'��Q1�IN:OT� li ,S'' ��l�pl rt , 11:�3� `�%uir• fji�!s':��Q.... � o "' •'' rKi•• �,. j•+ r t ' y +• •,:.:. i ,.� E;ryj- , •fi r < ".. :�.Y `� 4e e l A-: +�'xi t 1 • t •n .�4•ta, ^ 1i•• . ! lSL ° i ,t i G • , t r t e «t', ' 1rY L ,4 `( .3.y ra >: ti:c:•,•. nC eynT�.t {. �G ..- .,�� �.,.�..� ..�} L4 ry.. }5:.•t.� ".r� d , ;;.a• . .c._._I nn•-.�i. Day Telephone: 2 c:6 2(18 io 11 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 E • AUTHORIZED AGENT: Signature: --w- /' Date: r? • I — 0`3 • State Zip Date Application Accepted: Date Application Expires: �O Staff Initials: i a.44i ti�tn:NY.., , Ca :�:£`YL:. t irlt�A.f. na.: `a: %: ',+(ti+s]G��.j�: f i:G', } .is�: tG,t� :;t^Sv ' 55 •�S rY;c ' �;�•' Eat 1•• f �LilFit r`tiwt+, +:i2L;v 3Sti City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Z RECEIPT T W ce Parcel No.: 5379800600 Permit Number: M03 -213 v v 0 ` Address: 4402 S 164 ST TUKW Status: ISSUED N 0 Suite No: Applied Date: 12/15/2003 w W Applicant: CLAUSEN RESIDENCE Issue Date: 01/22/2004 - ' W O a5 Receipt No.: R05 -00302 Payment Amount: 49.50 u. a c d Initials: SKS Payment Date: 03/01/2005 01:51 PM H W . User ID: 1165 Balance: $0.00 ? i 1- O Z I- 0 D C3 O— 0 I - I V Amount LL, ~O Payment Cash 49.50 W c o U =, O 1— z Payee: JASON BROOKS TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - RES Account Code Current Pmts 000/322.100 49.50 Total: 49.50 0380 03/01 9716 TOTAL 49.50 doc: Receipt Printed: 03 -01 -2005 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 5379800600 Address: 4402 S 164 ST TUKW Suite No: Applicant: CLAUSEN RESIDENCE Payee: CLAUSEN FISHERIES,INC. ACCOUNT ITEM LIST: Description doc: Receipt Payment Check 1337 MECHANICAL - RES PLAN CHECK - RES RECEIPT Permit Number: M03 -213 Status: APPROVED Applied Date: 12/15/2003 Issue Date: Receipt No.: R04 -00065 Payment Amount: 65.00 I Initials: SKS Payment Date: 01/22/2004 03:28 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount 65.00 Account Code Current Pmts 000/322.100 52.00 000/345.830 13.00 Total: 65.00 6783 01/23 9716 TOTAL 713 25 Printed: 01 -22 -2004 COMMENTS: tt � I., vX0tvx■ Y e r c"v Q r Sr ry o - C t AU O rk - v fl uv\ ui ev P - `ekc kOoN P T 6 't rA/V\ — \ i �-■ p-e 0 - S 54 - evv\ . it r AN5S Wrt- ¶ j , r v a vci Ca ( e G v-1 Lk1a . " 1-1, \ A Mt A ∎r Q∎ ietk \. r c) 1 P t. S S Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Projecy` ( IG)SSPr - PS Type of Inspection: frOc -treSC . Address: ; S � �P -I try Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: t. z INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. Inspector:" s&i9 Date:' , 5 04.,' $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Type o pection: roc) rr� SS 4 p ) 5P Y e LA() V on -1 cam. V',n ct 0 r (vak . 3o4 o∎4e $/' PA (Li �-o✓ - � ' VA l y cN4 .tr rA( Ir5r , 9c - A :0I^ . tOni k S ,ror a.m. p.m. Requester: Phone No: Project: C(GVc4 - er 1 Type o pection: roc) rr� SS Addre 10 S 1 to)-1 gl Date Called: 6- oZ 1 Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 M03 (206)431 -3670 El - Approved per applicable codes. 0 Corrections required prior to approval. Inspector- (Date: - ,)9 -Ott $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: r B. C. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RESIDENTIAL HEATING AND VENTILATION COMPLIANCE FORM (Complete Sections I and II for Group R Occupancies 4 Stories or Less) Project Name: ChlzrzA) lSuf Site Address: ( -)y � 5. 169 4^ I. WASHINGTON STATE F,NERGY CODE HEATING DESIGN METHOD (select A, B or C below): 4 A. ❑ System Analysis — W.S.E.C. Chapter 4 (submit documentation) 0 Component Performance Approach — W.S.E.C. Chapter 5 (submit documentation) -- - UILGIhlG DIVISION Prescriptive Option — W.S.E.C. Chapter 6 (for prescriptive, complete the following calculation): House Square Footage (heated space): Z -,Q X 20 BTU/h = 23 ❑ Heating System Installed, (check system type below): RECErU WII -F, CITY OF DEC 1 5 2003 II. WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (select A or B below): 1. ❑ Electric Resistance 2. ❑ Electric (forced air) 3. i2r Other Fuels (gas, heat pump) A. ❑ Ventilation by Performance or Design Method - W.S.V.I.A.Q. Section 302 (submit documentation). B. ❑ Prescriptive Ventilation Options - W.S.V.I.A.Q. Section 303 (select one of the following): 1. ❑ Ventilation using Exhaust Fans (Section 303.4.1.) ❑ Exception for outdoor air inlets — Forced air heating system w /interior doors undercut 2. ❑ Ventilation integrated with Forced Air System (Section 303.4.2.) 3. ❑ Ventilation using Supply Fan (Section 303.4.3.) 4. ❑ Ventilation using Heat Recovery System (Section 303.4.4.) Er Prescriptive Minimum /Maximum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form). 1. House Square Footage: 2 �� 2. House Number of Bedrooms: 3. Required Outdoor Air Table 3 -2: Minimum - 4 1 0 / cfm Maximum - ( cfm Effective: 7/1102 tapplicationstheatinp and ventilation system — form h-6 (7.2002) MECHANICAL PERMIT APPLICATION NO.: BUILDING PERMIT APPLICATION NO.: Permit Center /Building Division: 206 - 431 -3670 Public Works Department: 206 - 433 -0179 Planning Division: 206 -431 -3670 Mo3 -u0 7.b cI g<te CITY OF TUKWILA APPROVED JAN 2 ; 2004 AS it Maximum BTU of Heating System Output Floor Area, ft2 Bedrooms . 4._ IA* , : or'less 3 4 5 6 7 8 k -.A Y•.';►. Min': +.Max Min Max Min Max Min Max Min Max Min Max Min Max '' j<5 s ! 60 ,. .—T5 65 98 80 120 95 143 110 165 125 188 140 210 t;: w ',:t :501�1' . r ' � r'5h� b "!,` ':,...Wi' .; V .�, :��:�., �t ti"+$ii1i'. ',�. ra105 '.,;t: ? , �i 128; >. -100;; ;:150•;'1 '1x15- :. 1;73:'.: '�: '130': :195•. '�` F-1 ` <i218 :f 1001 -1500 60 90 75 113 90 135 105 158 120 180 135 203 150 225 :1 ., S01i,2000L`• -.;': ';.":653 's`98; a ';: °: "'.. `i'120 :: s - 95 ° '143'l10 ' 1 :'' ti,1B8 = 1:140° :2,10' 1155:" 233'i 2001 -2500 70 105 85 128 100'a 150. '11:5∎' a.1.73.. .10 195. 1 i '218 160 240 `?.x•• ;` = :75 :: ::'1:13; , -9Q'' '135 4057: ',ASP. F 120 :.i18O 015:; i?203 . '1 :1 , "7225 7165is k2481, 3001 -3500 80 120 95 143 110 165 125 188 140 210 155 233 170 255 .i 3501 4000';.' zi8S 428' :` :' :100 : = 1:15(K X1`1:5` : -' 130 ' 5 .1195 445'1 .:x2181 .= :16U.' :!` :=240 4-7.1 :426V, 4001 -5000 95 143 110 165 125 188 140 210 155 233 170 255 185 278 '' ' ;-- 5001.6000.(.; < :n ,- .:.•.. :� ;* , sv _,,. ..158 ' ;'1;20' ,. .. , <tBQ :� ;, z %135<< tom . ;. i t •x;150.: > .._ �225� :.165: w. V2 48w M804 ' .270'x' :;195 `j293!„Ft 6001 -7000 115 173 130 195 145 218 160 240 175 263 190 285 205 308 `. ' 7001-8006 .: ';'125 ; '.'1.88 ` .' ;; x,210 ", ^ 1 '.;'233' ` `,'s 1'7' .. ?.-255 :146V', :'7278'`: '2001 ,i4 00g ;':115 : ..:36 8001 -9000 135 203 150 225 165 248 180 270 195 293 210 315 225 338 _,P2 :.. : >9000!0.... 145if `�218. '.`t 60' : °:240:{ :x,:1.75'. = :263,' ;:i'l 90' i :2�'. °�i. '205 ?.. i :3b8,.:; `220's,130`, :'235! ;;;353';: Fan Tested CFM 0 0.25" W.G. Minimum Flex Diameter Maximum Length Feet Minimum Smooth Diameter Maximum Length Feet Maximum Elbows' 50 4 inch 25 4 inch 70 3 . -?. :-1, 3 !�' . j z: , � ?: ...... j :- , >,� :50 . : /:�.. u , '' .'L'. ='7:' � :ri %r:,a.. `.x.� ,.. 5'ir1C11 :. :�'•.._, : :,. f:;. .t �'•' -4'' 90:.,.. r. ..., ....71: ' f <:l "! : ' - Y�,'. r; e.0 ; .Fk?> .,., . _ `. .l•.:•�' • :7'' a "` ±;< :;.' :. :.1.00 <'.. . .. , 1 't,•:i1':. - : :� :;, t }ii '.�ih : � - -, .. :,.�z•.;,,1`i.�;.� 50 6 inch No Limit 6 inch No Limit 3 �a :2 'g .i "'.1 ?t, . .,«80.�'�.,•,�,. .:,, :.'.,' ?:? •2..''' ',` 4 :;� 4'inch s' t . + F. `:' :C;' ,;y � :. >a�. : :a + '�;xNip►' ! : : st ., Cr',� '! .:;r �' ?�4��iticii?"�, : a i:,&a.{;+? , :•v. Y'i= 1 'jF'-' = �.'. ,: ..,.,..,20���,.,,r,. :.•- .,'�.. `v:? : =.F 'a .,..,.�„ �.� ; �x �.�3'. ;�,!r.���„ - 80 5 inch 15 5 inch 100 3 :vi r: :: '':rc� r, ?.,;TMy %'i � .4 :.,80. :�> .���..., � ' g,f `'s',§71';.n',+ . - . - _. � :6 "i ch .'' ! .., ;.r. .z :,;, ��.a „a��90 .. 5 � : : :' i = ��� :�. ;,� :ec, :” >r aiA C:: .,, :rr - :�' fri „�:•,. "!,` ':,...Wi' .; V .�, :��:�., �t 100 5 inch' NA 5 inch 50 3 .. ` 1.00 6:irich _... ... :45 °� :. ;',: ..,:.. "6 incH':',: , . .. r ..No.ltrrnt = .,. .` :1' .. . 125 6 inch 15 6 inch No Limit 3 c.. <s. � ';125f; .,•'+1:!: e. r . '.i T; !. �•3, ..,� .7�tncii'' ._..��w)�1 :.[ :'F':, .�'- '..b -, X70 . :1����:,�+ y. { e i'•'. ,7_�inch ^: .,, . ��> 7',;:.... No`Limrt '- t : ' : ..4 ?`n.. �; .:.. � 3, —A� TABLE 3 -2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) For residences that exceed 8 bedrooms, increase the minimum requirement listed fo 8 bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 times the minimum. Effective: 7/1/02 %applicationstheatinp and ventilation system - form h-6 (7 -2002) 1. For each additional elbow subtract 10 feet from length. 2. Flex ducts of this diameter are not permitted with fans of this size. TABLE 3 -3 PRESCRIPTIVE EXHAUST DUCT SIZING I N T E G R I T Y> Type of Appliance Operation Exhaust system Rinnai model number Minimum /Maximum gas rate (Input Btuh) Electrical Electrical consumption Hot water capacity Temperature range (with remote) Temperature (without remote) Approved gas types Installation Dimensions Weight Energy Factor Thermal Efficiency Service Connections Rinnai 13 -3/4" FILE COPY r B� 0 O NO Temperature controlled, continuous flow, gas hot water system. With or without remote controls, mounted in kitchen, bathroom, etc. Direct vent, forced combustion REU-2532W-C-US 15,000 BTU's - 199,000 Btuh Natural ane Appliance - AC 120 Volts - 60Hz. Remote control - DC 12 Volts Normal Standby Anti -frost protection 0.5 to 6.5 GPM (50 °F rise): MCC controller 96 - 180 °F 140 °F (Factory Default) y! C c; G Natural or Propane - Ensure unit matches gas type i External Only 48 Lbs. Natural Gas: 0.82 Natural Gas: 84% Gas supply 3/4" MNPT Cold water inlet 3/4" MNPT Hot water outlet 3/4" MNPT INCOMPLETE TO halbION NO 2. LTR #_I- 72 watts 5.5 watts 84 watts 0.7 t 2532W -C II 1 s an Cnn V I pt R Abb MAICE t JAN 2 4 2005 8.5 GPM (35 °F rise) Wlla tom CABLE ACCESS Ca 0 WATFR IM FT FOaER SUPPLY Propane: 0.84 Propane: 85% RECEIVED CITY OF TUKWILA JAN 1 8 2005 PERMIT CENTER 2532W - SP - MD3Z13 C I N T E G R Ignition system Water temperature control Water flow control Minimum /maximum water supply pressure Water Flow Capacity Curves (For 1 to 5 units manifolded in parallel) Safety Devices Remote Control Remote control cable Clearances from combustibles Clearances from non - combustibles Clearances from Eaves, Porches, Overhangs Clearances from Opening, Window, Door, etc. Min. and Max. gas supply pressure Manifold Gas Pressure (Inches W.C.) Warranty Rinnai Direct electronic ignition Simulation feed forward and feedback Water flow sensor, electronic water control device, and electronic by -pass control device 20 —150 PSI (50 or above is recommended for maximum flow) 7 1 _i 1 Unit —2 Units 3 Units —4 Units — 5 Units MIME Mi, L M MU I . L 45.0 40.0 35.0 8 30.0 • X • 25.0 .2 20.0 • 15.0 • 10.0 5.0 0.0 0 25 50 75 100 AT— Temperature Rise CF) www.rinnai.us 125 150 • Flame failure - Flame rod • Remaining flame (OHS) • Boiling protection - 203 °F • Thermal fuse 264 °F • Combustion fan rpm check • Automatic frost protection • Over current - Glass fuse (3 amp) MCC -45 -4 US Main Control (96 -180 °F range) Non - polarized two -core cable • Top of heater 12" • Back of heater 0" • Front of heater 24" • Bottom of Heater 12" • Sides of heater 6" • Top of heater 2" • Back of heater 0" • Front of heater 24" • Bottom of heater 2" • Sides of heater 1/2" • Installations within RGB -25 Recess Box: Clearances from combustibles to recess box top, bottom, back and sides = 0" Top of heater 36" From Vent Discharge 12" Natural Gas: Min. 6" W.C. Propane Gas: Min. 10" W.C. (NAT) Max. 10.5" W.C. (LPG) Max. 14" W.C. Natural Gas: 3.4" W.C. high fire 0.56" W.C. low fire Propane Gas: 5.1" W.C. high fire 0.88" W.C. low fire Five years heat exchanger / five years parts Technical Support: 1- 800 - 621 -9419 ti ity Certificate: 1307478 (113206) Project: 1384553 Issued to: Rinnai America Corporation 103 International Drive Peachtree City, GA 30269 USA Attention: Certificate of Compliance PRODUCTS REU- V2532W- US -(N,P) REU -V2532 W C- US -(N,P) James A. Cika CSA INTERNATIONAL The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' US Class No.: 2902 -93 Commercial Heaters (Gas) Water Heater For Outdoor Installation Only Maximum Electric Input Model Number Rating Rating For Use With Natural and Liquefied Petroleum Gases Instantaneous Water Heater for Water Heating and Spacing Heating Master Contract: 189893 Date Issued: Dec. 11, 2002 Issued by: Robert Loria Authorized by: George Gruss Operations Manager Trade Name: RINNAI CONTINUUM 199,000 15,000 199,000 15,000 Minimum Input Storage Rating Capacity Altitude The 'C' and 'US' indicators adjacent to the CSA Mark signify that the product has been evaluated to the applicable CSA and ANSI/UL Standards, for use in Canada and the U.S., respectively. This 'US' indicator includes products eligible to bear the 'NRTL' indicator. NRTL, i.e. National Recognized Testing Laboratory, is a designation granted by the U.S. Occupational Safety and Health Administration (OSHA) to laboratories which have been recognized to perform certification to U.S. Standards. DOD 507WD 2002/04/30 Project: 1384553 MARKINGS DOD 507WD 2002/04/30 • CSA INTERNATIONAL Certificate: 1307478 Master Contract: 189893 PRODUCTS Class No.: 2902 - 13 Commercial Heaters (Gas) Water Heater For Outdoor Installation Only Date: Dec. 11, 2002 Maximum Minimum Electric Input Input Storage Model Number Rating Rating Rating Capacity Altitude For Use With Natural and Propane Gases Instantaneous Water Heater for Water Heating and Space Heating Trade Name: RINNAI CONTINUUM REU- V2532W- US -(N,P) B 199,000 15,000 N B 179,100 13,500 H REU- V2532WC-US -(N,P) B 199,000 15,000 N B 179,100 13,500 H APPLICABLE REQUIREMENTS ANSI Z21.10.3- 2001•CSA 4.3 -2001, Gas Water Heaters, Volume III Gas Fired Automatic Storage Type Water Heaters with Inputs above than 75,000 BTUH, Circulating and Instantaneous All markings and printed instructions are in compliance with the above mentioned requirements. Samples are contained in the main certification report. • CSA INTERNATIONAL Supplement to Certificate of Compliance Certificate: 1307478 (113206) Master Contract: 189893 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 1384553 Dec. 11, 2002 Changed NGK flame `sensor to Teikoku Tsushin and corrected drawings per mfr.'s 10/17/02 letter. Replaced drawing Nos. 0000 (03,04,06,07,12,13,40,43,52, 54). 1343789 2002 -09 -16 . Authorized recess box for outdoor water heater. . 1307478 • 2002 -06 -24 Original Certification. DOD 507WD 2002/04/30 Model number series REU- V2532W(C) -US APPLICABLE REQUIREMENTS ANSI Z21.10.3- 2001•CSA 4.3 -2001 CSA INTERNATIONAL Edition 1: 2002 06 - 24; Project 1307478 - Cleveland Issued by Alberto Nieves Editioti.2: 2002- 09 -16; Project 1343789 — Cleveland Issued by Alberto Nieves Edition 3: Dec. 11, 2002; Project 1384553 - Cleveland Issued by Robert Loria Contents: Certificate of Compliance - Page 1 to 2 Supplement to Certificate of Compliance — Page 1 Description and Tests — Pages 1 to 6 Drawings - Markings- Instructions — Pages 001 to 065 Class No.: 2902 -93 Commercial Heaters (Gas) Water Heater Class No.: 2902 - 13 For Outdoor Installation Only MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 Gas Water Heaters, Volume III Gas Fired Automatic Storage Type Water Heaters with Inputs above than 75,000 BTUH, Circulating and Instantaneous The test report shall not be reproduced, except in full, without the approval of CSA International. 8501 E. Pleasant Valley Road, Cleveland, OH, U.S.A. 44131-5575 Telephone: 216.524.4990 1.800.463.6727 Fox: 216. 642.3463 www.csa- international.org Descriptive and Test Report MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 MARKINGS All markings and printed instructions are in compliance with the above mentioned requirements. Samples arc contained in the main certification report. ALTERATIONS New Report no changes were required FACTORY TESTS Factory test to be in accordance with Part III of the applicable requirements detailed in the Certificate of Compliance TESTS See Main archive file for details of testing Page No: 2 Date Issued: Dec. 11, 2002 Left Side: 6 inches Right Side: 6 inches Rear: 0 inch Top: 12" Floor: 24" • MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 Character Description R Rinnai E Export U Water Heater (U- wakashiki in Japanese) ✓ Project Number 25 Max Capacity (liter /min) at 25° C rise 32 Project Number W Outside Wall Installation C Commercial US American and Canadian Specification N Natural Gas P Liquefied Petroleum Gas Manifold Pressure Natural Gas Liquefied Petroleum/ Propane Gas Minimum Inlet Pressure Natural Gas Liquefied Petroleum/ Propane Gas Maximum Inlet Pressure Natural Gas Propane Gas MODEL NUMBER BREAKDOWN OPERATING PRESSURES Max Rate 3.4 inches w.c. 5.1 inches w.c. 6.0 inches w.c. 10.0 inches w.c. 10.5 inches w.c. 14.0 inches w.c. CLEARANCES ELECTRICAL RATING Page No: 3 Date Issued: Dec. 11, 2002 Min Rate .56 inches w.c. .88 inches w.c. 120 volts 3 Amps 60 Hertz 1 Phase tY W 0 O, N 0 W = CO IL: Lu 0 LL QI = a , � Wm I- 0 Z H: ILI a l o 1—` w w, EL): U tL. 0. . uj U N Z. MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 Read columns vertically for complete assemblies GAS CONTROL ASSEMBLIES Electronic Ignition Systems Page No: 4 Date Issued: Dec. 11, 2002 Z Type of Mfr. of Model Size of Control 1 ' Control Control Number Natural Propane Y � W t QQ . Combination Rinnai Seiki C36E -41 -S 1 1 U O Control NO W W J Ignition . R. B. Controls EI -189 x x N u_ Module W O }} 5. u_ Q Ignitors) NGK H73 -120 x x N D. _ . Flame Teikoku Tsushin AH41 -216 x x z 1.-, Sensors F - O Z I— M > Manual Jomar T- 20(3,4) 3/4 3/4 U t]. Valve ,Cl O — H W W H V O Z U1. ' 0 MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 COMBUSTION AIR MOTOR: TRANSFORMERS: Manufacturer WIRE AND CONDUIT: RELAY: Manufacturer Model No. Location Omron Corp. ELECTRICAL EQUIPMENT Ratings Manufacturer Model RPM Amp Volts HZ Phase Shinano Kenshi Cop H89- 262 -CW 4,320 Hi. .9 35 60 1 1,920 Low .3 14 60 1 COMBUSTION AIR BLOWER WHEEL(S) AND BLOWER HOUSING(S): Blower Wheel Blower Wheel Blower Size No. Housing Manufacturer Model No L X Dia. (in.) Blades Mfr. Size(in.) Nisshin Bou H89- 263 -CW 1.57 IN. L. x 3.74in. Dia. 63 Tekuno Parts 5.19 • Model'. . Ratings Class Page No: 5 Date Issued: Dec. 11, 2002 Tamura Seisakusho ET -281 120 VAC E(UL 1411) LIMIT SWITCH(ES): Manufacturer Model Type Setting Size(in) Nihon GT BU129 -824 -2 NC BiMetal 194 °F. Voltage Temperature Manufacturer Gage Ratings Ratings Application Sumitomo 18 AWG 600V 221 °F UL 1015 Hitachi 20 -24 AWG 300V 221 °F UL 1015 PCB Application UL 41515 001 — 002 003 004 005 006 007 — 009 010 011 012 013 • 014 -015 016 017 — 026 027 028 029 030 — 034 035 036 037 038 040 040 041 042 043 — 044 045 046 -049 050 051 052 —053 054 — 055 056 -058a 059 060 061 062 — 065 MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 PAGE NO. DESCRIPTION Manufacturers tolerances have not been verified. CSA International DRAWING - MARKING - INSTRUCTION INDEX Unit Photograph Details Unit Outer Dimension Details Unit Cut -away Diagram Details Schematic Component Diagram Details Casing assembly Details Unit Panel Details Wall Installation Bracket Details Heat Protection Plate Details Heat Exchanger Assembly Details Manifold Assembly Details Burner Unit Details Damper Details Combustion Chamber Details Conformable Window Details Front Scaling Packing Details Front Panel Packing Side Details Ignition System Details High Tension Cord Details Water Filter Assembly Details Actuator Assembly Details Gas Connection Details Lower Packing Details Duct Assembly Details Duct Casing Details Upper Packing Details Flue Outlet Details P.C.B Details Blower Motor Assembly Details Transformer Details Over Heat Switch Details Water Inlet & Outlet Component Details Wiring Diagram Details Marking Installation Instruction Commercial Installation Instruction T/S Basic Operation Details Addenda to Installation Manuals Page No: 6 Date Issued: Dec. 11, 2002 0O 0 ; W W N W W 0 ` g - to ICI H Z F- 0 `. Z H: D 0 0' 0 N' 1 — W W H r . u- O : 1 11 2 . Z 3204 N.E. 145th Street Shoreline, WA 98155 -7528 206 - 267 -4334 fax Owner: Clausen Residence 4402 S 164 St Tukwila, WA 98188 DESIGN REPORT Plan review approval Is subject to; ' " and omissions:, i Approval of construction documents does** the violation of any adopted code or ordinance, of approved He and conditions is acknowledged: BY Date: , City of witilcvvila 3/16/2004 By: Jason Hewitt INCOMPLETE LTR# 206 - 267 -4328 ph Job site: REVIEWED FOR CODE COMPLIANCE APP R0VED JAN 2 4 2005 OF Tukwila D IVISION Same SEPARATE PERMIT REQUIRED FOR: 4 Mechanical C1 1 / Electrical � LZ/ Plumbing u Gas Pip'ng City Of Tukwi a BUILDING DIVISION Rio changes shall be made of WO C'iS E" .� "_ Include p r ♦ "' ' taros►al of r zlifa t :-:1 IyizEklE tg ,y vision. NOTE: R ;,fw;on3 will re end may Include plan plan r .,.. plan revic RECEIVED CITY OF TUKWILA JAN 1 8 2005 PERMIT CENTER � �`�'_� • 170 3-2/3 TABLE OF CONTENTS Summary CAD Drawings Floor Sections AutoCAD Loop Drawings, Length and Location Boiler Schematic Heat Loss reports Material page Heating design summary Manifold summary Drawings SUMMARY Owner: Clausen Residence Job site: Same 4402 S 164` St z Tukwila, WA 98188 n: w . u6 JU . 0 CO 0 Deliverables: w w services Northwest Mechanical is providing in this design report: J The following P g � � P cn u. Floor sections, loop drawings, boiler schematic, heat loss report. w 0 ga =C� Design: The following design criteria were used in determining the heat load for the homeowner. al • Winter indoor temperature of 70 °F, and outdoor temperature of 21 °F. z • Summer indoor temperature of 74°F, and outdoor temperature of 90 °F. z O0, • Temperature extremes based on 0.2% of design dry bulb temperature. w w 2 • Temperature variations are based on ASHRAE © 1997 v • Air ventilation based on WAC 51 -11 402.1.5 as 0.35 air changes per hour. .p u) r • All dimension rounded to nearest half foot. 01— w w z O ~ z.. Assumptions made unless specified in the plans. R- values: Floor coverings: hardwood 0.80, tile 0.3, vinyl 0.10, linoleum 0.12, stone 0.50, and carpet or hardwood with two layers of plywood 2.0. Ceilings 38, Walls 21, Floor 30, Entire Slab 10. U- values: Windows 0.40, and Doors 0.20. No radiant or supplemental heat in any closet, storage, mechanical room, pantry, wine cellar, garage. Room Name Zone Tube spacing Length of tubes Manifold Manifold water temperature Floor R- Required supplemental heat Alternate heating type Hall House_Z 8 73 Manifold 149 Hardwood 1 0 Kitchen House_Z 8 273 Manifold 149 Tile 0.3 0 Laundry /Rec Base_Z 12 231 Manifold 149 Concrete 0 0 231 Living Dining House_Z — 8 294 Manifold 149 Hardwood 1 0 294 Music Music_Z 12 200 Manifold 149 Concrete 0 0 Office Office _Z 8 227 Manifold 149 Hardwood 1 0 Workshop Base_Z 12 218 Manifold 149 Concrete 0 0 Entry House_Z 2,938 Stairs House_Z 0 Bath House_Z 2,025 Nuheat Base Stairs Base_Z 0 Master Bed Upstairs_Z 3,143 Master Bath Upstairs_Z 2,048 Top Hall Upstairs_Z 74 Top Stairs Upstairs_Z 1,130 Closet Upstairs_Z 1,024 Storage Upstairs_Z 792 Bed Upstairs_Z 2,605 Report: Heat loss summary table 112" WIRSBO HEPEX TUBING STABLED TO SUBFLOOR FLOOR JOIST WITH R -19 MIN 4" SLAB WITH FIBERGLASS REINFORCING 112" WIRSBO HEPEX STAPLED TO INSULATION 2" R -10 POLYSTYRENE INSULATION 6" BASE MATERIAL PROVIDE PROPER DRAINAGE FOR STANDING WATER AROUND BUILDING C. 4- D C B A 8 8 aNmunooa 3141 AO )liflVflO 9H1013la SI ll 30I10N SIHI NVHJ, 21V310 9531 SI 31 SIHl NI 1N3W11000 3H1 AI :30110N 7 7 6 6 5 5 4 4 3 3 2 2 1 1 n C B A 121VdV ..1 .S 15101 NMOO AVM 3H1 AO E/1 310H .Z /110 NM 61 H11M IIVM aN V 1SIOr 210011 13d21VO 11VM31VIfSNI 000101101 0r Atrifffeityr# AISTAVZSMITY 3N001113 HIIM 31Vld NOISSM3 1V3H WnNIWnIV 0103XIdiV S2131N30 .8 NO X3d3H OSS211M 2/1 doOlu9ns .b/E OVd H11M 13daVO NIW 6t H1IM IIVM ONV 1SIOf 21001] NIW 61. IIVM ONV 1S10r IOo13 311/1S21O3111 GOOMa21VH ., 00010010 ioriff-We Zz , 000MOaVH 3NO0I1IS I{LIM 31Vld NOISSM3 1V3H WnNIWniY 01 O3X113V S1131N30.8 NO X3d3H 09S IIM 211 3N001II5 H1IM 31Vld NOISSIW3 1V3H WON wn1V O103XIidV 52131N33 .13 NO X3d3H 09SdIM 2/1 ao0139ns .) /E b 9 9 a 1. Z 9 9 L L NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 9 9 V 9 O a 4 1 .oLz .091 Ql03INVW 3aISlfO 031`d001 2131V3H 1 .091 F v 9 0 0 L Z 9 9 L L 9 8 v 8 0 0 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 4 1` .0EE .0£Z / .OLZ V 9 0 L 1. 9 9 L L NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR 'THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 9 8 V 8 0 a 1:8 1301.Y11.520 3M1701 MOO =I F ;ATM TWO JaleaH Jalem 3snoH cu. 13.1.VM 10H Josuas Auei 3A1VA9NIXIMAVM C 2A7101 3114� 3ATIAI03WJ 301ra itiniveilkintal. 45 Id =0:a=1/ -//// b130NYHOX3 .LV3H 1. INPUNCISNVdn ci 2ELLVM 0100131Ni 1 Zd r 4 V 8 0 0 1. z -17 9 9 L L 9 8 V 8 0 a NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. V 9 0 0 t J a' ld Zd dAl SdWfld :Z -Ld OVAVZ - - -- OVAOZL -- S 9 9 L L NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 9 8 V 8 0 a Oil ON ON ON ON 9 9 9 ti t7 £ H N -I 7J 101138 3NOZ L OOVl V 9 0 0 t J a' ld Zd dAl SdWfld :Z -Ld OVAVZ - - -- OVAOZL -- S 9 9 L L NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 9 8 V 8 0 a 1 Partitions (none) For: Location: For • Intl AP, W� US Latitude: 47°N Outdoor: • bub (°F) Wei bid Wind() Doors 1100: Metal door, polystyrene core, with storm Component Constructions Entire House Northwest Mechanical 3204 NE 145th ST, Shoreline, WA 98155 -7528 Phone: (206) 267 -4328 Fax: (206) 267-4334 Email: jesonOnwmechanlcal.com Web: www.nwmechenicel.corn Pro ect Information Clausen Residence 4402 S 164th ST, Tukwia, WA 96188 Design Conditions Heating 21 10.0 Construction descriptions Walls 12E -Osw: Wood stud frame, siding or stucco, no board insulation, R -19 cavity insulation 12C -Osw: Wood stud frame, siding or stucco, no board insulation, R -13 cavity insulation 15B13- 0wc -4: Basement - 8" concrete, wood framing, interior finish, R -13 cavity, no board insulation, 4' Windows 4A1 -2ov: Operable, vinyl frame, low -e glass, e=0.20 surface 2, 2 pane BAcw -2w: Skylight, clear, small wood curb, 1 pane, wood sash Indoor: � 8(19 Relative humidity (%) Cooling Moisture difference (gr11b) 18 (M) Infiltration: 64 Constudion quality 10.0 Freplaces Job: 5048 Date: 3/10104 By: J Hewitt Heating Cooling 70 16 30 50 20.4 -16.5 S Average 1 (Average) .• vvrigft-IItsc ft Right -Suite Residential 5.9.34 RSR21411 \\Nwm11Shared1Design - JesonlProjecls \Clausen Residence 5048 \Clausen.rrp Cale = MJ8 Orientation Or Area U -value insul R Htg HTM Loss Dig HTM Gain (f') (BtuMf -'F) (RL'FBtuh) (BtuIVW) (Bt oh) (MOM) Ruh) n 184 0.068 19.0 3.33 613 1.31 241 e 112 0.068 19.0 3.33 373 1.31 147 w 76 0.068 19.0 3.33 253 1.31 99 all 372 0.068 19.0 3.33 1240 1.31 487 n 205 0.091 13.0 4.46 914 2.12 436 e 308 0.091 13.0 4.46 1374 2.12 655 s 349 0.091 13.0 4.46 1556 2.12 742 w 376 0.091 13.0 4.46 1678 2.12 799 all 1239 0.091 13.0 4.46 5522 2.12 2632 n 169 0.059 13.0 3.45 584 0.39 66 e 218 0.059 13.0 3.58 780 0.48 104 s 190 0.059 13,0 3.57 679 0.48 90 w 212 0.059 13.0 3.55 753 0.46 97 all 789 0.059 13.0 3.54 2796 0.45 358 n 40 0.470 0.0 23.0 921 16.6 663 n 33 0.470 0.0 23.0 760 18.6 547 n 6 0.470 0.0 23.0 138 16.6 99 e 20 0.470 0.0 23.0 461 52.8 1057 e 57 0.470 0.0 23.0 1313 52.8 3012 e 6 0.470 0.0 23.0 138 52.8 317 s 80 0.470 0.0 23.0 1842 31.6 2525 s 6 0.470 0.0 23.0 138 31.6 189 w 78 0.470 0.0 23.0 1796 52.8 4122 w 12 0.470 0.0 23.0 276 52.8 634 all 338 0.470 0.0 23.0 7784 39.0 13167 12 1.160 0.0 56.8 682 168 2012 n 21 0.210 0.0 10.3 216 5.95 125 2004 - Mar -16 15:56:25 Page 1 11DO: Wood door, solid core, no storm e 21 0.390 0.0 19.1 401 11.1 232 Callings 18A -38ad: Ceiling below roof Joists, dark shingles, R -38 blanket 828 0.029 38.0 1.42 1177 0.69 573 or loose fill 16B -38ad: Calling under vented attic, no radiant barrier, dark 106 0.026 38.0 1.27 134 1.35 142 shingles, R -38 insulation Floors 22A -wph: Hardwood covered slab on grade, heavy moist soil, 20 1.358 0.0 66.5 1331 0.00 0 No edge haul, No horiz insul 43C0: Rad.Pnl floor room, 3/4" ply subflr, staple up 720 0.000 0.0 0.00 0 0.00 0 45A0: Radiant Panel- Concrete basement slab, embedded tubing 868 0.000 0.0 0.00 0 0.00 0 wrightsc ft Right-Suite Residential 5.9.34 RSR21411 \ \Nwm11Shared1Deaign - Jeson1Projects 1Clausen Residence 5048 \Clausen.rrp Cale = MJ8 Orientation Page 2 2004 - Mar -16 15:56:25 Ram name Room area (ft') Air tarp ('F) Room load (Btuh) Supp. he (Btuh) F/C Panel area (ft') Tubing area (ft') Surf. temp. (`F) Deily. trip. ( F) Panel output (Btuh /ft') Back loss (Btuh /ft') Music 182 70 516 0 LL LL LL LL LL LL LL 182 180 71 149 3 0.2 Living Dining 377 70 5702 0 355 352 79 149 16 3.0 Entry 50 70 2938 2938 Stairs 28 70 0 0 Hall 44 70 0 0 44 42 68 149 0 0.0 Kitchen 221 70 3503 0 178 175 81 149 20 3.2 Bath 84 70 2025 2025 Workshop 221 70 956 0 221 218 72 149 4 0.4 Laundry/Rec 466 70 1944 0 466 461 72 149 4 0.4 Base Stairs 28 70 0 0 Office 143 70 1561 0 143 141 76 149 11 2.1 Master Bed 310 70 3143 3143 Master Bath 112 70 2048 2048 Top Hall 52 70 74 74 Top Stairs 70 70 1130 1130 Closet 74 70 1024 1024 Storage 52 70 792 792 Bed 170 70 2605 2605 Totals 2682 I 29961 15778 1588 1569 "' ` -' ` Radiant Heating Design Summary Northwest Mechanical Job: 6049 Date: 3110/04 By: J Hewitt 3204 NE 145th ST, Shoreline, WA 98155 -7528 Phone: (208) 267 -4328 Fax: (206) 267 -4334 Email: Jason @nwmechanical.com Web: www.nwmechanical.com Project ,i nfor aioii For. Clausen Residence 4402 S 164th ST, Tukwls, WA 98188 Total floor area: Radiantly heated area: To panel area: Total tubing area: Total roan bad Total Total supplemental heat Total back loss: Boner output required: 2682 ft Design temperature: 1662 ft Ma>Qrnrn supply temperature: 1588 ft Total flow rate: 1569 ftz Ma cinum head loss: 29961 Btuh Total tubing required: 14183 Ruh Number of loops: 15778 Btuh Number of zones 2260 Btuh Number of manifolds: 32221 Btuh 21 °F 149 °Fm 5.03 ft H2O 2039 ft 9 5 1 ace', .eatin • In f %ri atio Wrnghtsc3ft Right -Suite Residential 5.9.34 RSR21411 11 Nwm11Shared1Design - JasonTroJects1Clausen Residence 50481CIausen.rrp Cale = MJ8 Orientation 2004 - Mar -16 15:56:25 Page 1 z W 6 J U U O N 0 CO W J NW w 0 cn _ ° H W Z = t- o . w ~ w Ca U 0 W w t - O, W Z U = . O Z Radiant Heating Manifold Summary Northwest Mechanical 3204 NE 145th ST, Shoreline, WA 98155 -7528 Phone: (206) 267-4328 Fax: (206) 267 -4334 Email: jesonOnwmechanical.com Web: w•w.nwmechanical.com Project Information, Totals for Manifold Max. head loss (ft H2O) Valves head in worst loop (ft H2O) Max. supply temp. ( °F) For. Clausen Residence 4402 S 164th ST, Tukwila, WA 98188 Job: 6048 Date: 3110104 By: J Hewitt Manicid name Manifold bcation: Manbid Name Heating zone Heated area (ft Room temperature ( °F) Cover R (ft Surface temperature ( °F) Radiant panel type Tube spacing (in) Tube type/size Distance to manifold (ft) Loop length (ft) Temperature drop ( °F) Flow (gpm) Head loss (ft H2O) Supply temperature ( °F) Balance valve (turns from closed) Loop number 1 Music Music Z 182 70 0.00 71 45A0 12.0 12" BPEX 10 200 79.4 0.01 0.00 149 2 Using Dining -A House Z 178 • 70 1.00 79 43C0 8.0 12" BPEX 15 294 19.2 0.36 1.79 149 3 UNng Dining -B House Z 178 70 1.00 79 43C0 8.0 1/2" BPEX 15 294 19.2 0.36 1.79 149 4 Hall House Z 44 70 1.00 68 43C0 8.0 1/2" BPEX 5 73 0.0 0.00 0.00 149 5 Kitchen House Z 178 70 0.30 81 43C0 8.0 1/2" BPEX 5 273 12.2 0.68 5.03 149 5.03 Total flow (gpm) Total panel output (Btuh) 149 Total tubing required (ft) wrnghtsoft Right -Suite Residential 5.9.34 RSR21411 11Nwm11Shared1Design - JasonlProjects1Ciausen Residence 5048 %Clausen.rrp Calc = MJ8 Orientation 1.55 14183 2039 continued... 2004 - Mar -16 15:56:25 Page 1 ,' ' `` •;;' , Radiant Heating Manifold Summary Totals for Manifold Max. head loss (ft H2O) Valves head in worst loop (ft H2O) Max. supply temp. ( °F) Northwest Mechanical For: Clausen Residence 4402 S 164th ST, RAW la, WA96188 5.03 Total flow (gpm) Total panel output (Btuh) 149 Total tubing required (ft) Wr.ghtsaft Right -Suite Residential 5.9.34 RSR21411 11 Nwm11SharedlDesign - Jason \Projects \Clausen Residence 50481Clausen.rrp Calc = MJ8 Orientation Job: 5048 Date: 3110104 By: J Hewitt 3204 NE 145th ST, Shoreline, WA 98155 -7528 Phone: (206) 267-4328 Fax: (206) 267-4334 Email: )asonOnwmechanical.com Web: www.nwmechanlcai.com Project Information Manbuld name Manifold bration: Manifold Name Heating zone Heated area (ft Room temperature ( °F) Cover R (ft °F/Btuh) Surface temperature ( °F) Radiant panel type Tube spacing (in) Tube type /size Distance to manifold (ft) Loop length (ft) Temperature drop ( °F) Flow (gpm) Head loss (ft H2O) Supply temperature ( °F) Balance valve (turns from closed) Loop number 6 WAshop Base Z 221 70 0.00 72 45A0 12.0 1/2' BPEX 0 218 79.4 0.03 0.01 149 7 LaundrylRec -A Base Z 233 70 0.00 72 45A0 12.0 12" BPEX 0 231 79.4 0.03 0.02 149 8 LaundrylRec -8 Base Z 233 70 0.00 72 45A0 12.0 1/2" BPEX 0 231 79.4 0.03 0.02 149 9 Office Once z 143 70 1.00 76 43C0 8.0 1/2" BPEX 8 227 61.7 0.06 0.06 149 1.55 14183 2039 2004.Mar-16 15:56:25 Page 2 Base MANIFOLD 1 Job #: 5048 Performed by J Hewitt for: Clausen Residence 4402 S 164th ST Tukwila, WA 98188 Northwest Mechanical 3204 NE 145th ST Shoreline, WA 98155 -7528 Phone: (206) 267 -4328 Fax: (206) 267 -4334 Scale: 1 : 59 Page 1 Right -Suite Residential 5.9.34 RSR21411 2004 - Mar -16 15:57 :17 11Nwm1■Shared■Design - JasontPr... Main Job #: 5048 Performed by J Hewitt for: Clausen Residence 4402 S 164th ST Tukwila, WA 98188 Northwest Mechanical 3204 NE 145th ST Shoreline, WA 98155 -7528 Phone: (206) 267 -4328 Fax: (206) 267 -4334 Scale: 1 : 59 Page 2 Right -Suite Residential 5.9.34 RSR21411 2004 - Mar -16 15:57:17 NNwm1 \SharedlDesign - Jason \Pr... L. t I ril tp Job #: 5048 Performed by J Hewitt for: Clausen Residence 4402 S 164th ST Tukwila, WA 98188 Top Northwest Mechanical 3204 NE 145th ST Shoreline, WA 98155-7528 Phone: (206) 267-4328 Fax: (206) 267-4334 ij Scale: 1 : 59 Page 3 Right-Suite Residential 5.9.34 RSR21411 2004-Mar-16 15:57:17 alwm1 \Shared\Design - Jason \Pr... HEAT LOSS RM X RMXSQFT 2580 $512.00 T -STAT WIRING TF1.01 PUMP CONTROL ELECTWIRE TSTAT 18 -3 60 $8.99 R21.08 RELAY 1ZN NIX SP81D 1 $57.60 PEX PIPE SA1.03B HEPEX PLUS .5 Al220500 2200 $1,408.00 BEND SUPPORTS R12.03 90 DEG EL 8 $6.78 CABLE TIES R10.01 7" LONG 1000 CT 0.25 $5.31 MANIFOLD R11.03 PORTS RED 8 $195.84 MANIFOLD R11.04 PORTS BLUE 8 $195.84 MANIFOLD R14.04 SBK FITTING ASSB .5 16 $83.20 MANIFOLD R11.01 BASIC KITS 1 $92.16 MANIFOLD R11.02 ISO UNION 1 $24.48 Electric Mats 41170 110V Floor Sensing Thermostat w /Built -in Timer 1 $219.52 Electric Mats Custom mat 1 $800.00 ENGINEERED FLOORIN 48592 WIRSBO JOIST -TRAK .375 41(4" 225 $1,404.00 SILICONE TUBES 8 $50.56 THERMOSTAT 1 R20.06 WIRSBO THERMOSTAT A3030101 4 $184.83 TELESTATS R11.08 SBK 16 $737.28 Parts Price $ 7,125 CIRCULATOR R19.01B UP15 -42FC FLOW CHECK 1 $112.00 PUMP FLANGE L26.02 FLNG .75 CI 519801 1 $9.41 CIRCULATOR R19.05 UP15-42B7 1/2 HP 1 $271.20 PUMP FLANGE L26.01 FLNG .75 BRZ ISO 1 $34.80 HEAT EXCHANGER 47893 FLAT PLATE .75 TAP 1 $304.00 BALL VALVE L30.09 1/2" 1 $6.00 CHECK VALVE L28.09 3/4" 2 $15.65 SPIROVENT R22.17 POWERVENT 1 THREADED *523913 1 $102.00 EXPANSION TANK TF2.04 *30 484021 1 $38.11 B.F.P. WATTS R22.22 1/2 009 -QT 1 $136.00 B.F.P. WATTS R22.23 AIR GAP 1 $27.89 AUTO FILL VALVE R22.01 TACO 329 -3 1 $49.60 LETRO THERM R15.07 SL -2 1 $32.00 HEAT LOSS T -STAT WIRING PUMP CONTROL CIRCULATOR PUMP FLANGE CIRCULATOR PUMP FLANGE HEAT EXCHANGER BALL VALVE CHECK VALVE SPIROVENT EXPANSION TANK B.F.P. WATTS B.F.P. WATTS AUTO FILL VALVE LETRO THERM PEX PIPE BEND SUPPORTS CABLE TIES MANIFOLD MANIFOLD MANIFOLD MANIFOLD MANIFOLD Electric Mats Electric Mats ENGINEERED FLOORING SILICONE TF1.01 ELECTWIRE TSTAT 18-3 R21.08 RELAY 1ZN NIX SP81D RM X RMXSQFT 2560 $512.00 60 $8.99 1 $57.60 R19.01B UP15 -42FC FLOW CHECK I $112.00 L26.02 FLNG .75 CI 519601 1 $9.41 R19.05 UP15- 42871/2 HP 1 $271.20 L26.01 FLNG .75 BRZ ISO 1 $34.80 47893 FLAT PLATE .75 TAP 1 $304.00 L30.09 1/2" 1 $6.00 L28.09 3/4" 2 $15.65 R22.17 POWERVENT 1 THREADED 0523913 1 $102.00 TF2.04 #30 484021 1 $38.11 R22.22 1/2 009-QT ' 1 $136.00 R22.23 AIR GAP 1 $27.89 R22.01 TACO 329-3 1 $49.60 R15,07 SL -2 1 $32.00 SA1.03B HEPEX PLUS .5 Al220500 R12.03 90 DEG EL R10,01 7" LONG 1000 CT R11.03 PORTS RED R11.04 PORTS BLUE R14.04 SBK FITTING ASSB .5 R11.01 BASIC KITS R11.02 ISO UNION 41170 110V Floor Sensing Thermostat wBuitt -in Timer Custom mat 48708 WIRSBO JOIST -TRAK 0.5 4'X4" TUBES 2200 $1,408.00 8 $6.78 0.25 $5.31 8 $195.84 8 $195.84 16 $83.20 1 $92.16 1 $24.48 1 $219.52 1 $800.00 225 $1,404.00 8 $50.56 THERMOSTAT 1 R20.06 WIRSBOTHERMOSTATA3030101 TELESTATS R11.08 SBK 4 $184.83 16 $737.28 Parts Price $ 7,125 Type of Appliance Operation Exhaust system Rinnai model number Minimum/Maximum gas rate (Input Btuh) Electrical Electrical consumption Hot water capacity Temperature range (with remote) Temperature (without remote) Approved gas types Installation Dimensions Weight Energy Factor Thermal Efficiency Service Connections Rinnai 13 -3/4" 1 -1 • m M N 1 understand that the Plan Check approvals are ub :apt to cr and crr!is ions and approval of Temperature controlled, continuous flow, •gas hothw4t . ystem. With or without - remote controls, mounted in kitchen, bathroom Direct vent, forced combustion REU- 2532W -US 15,000 BTU's - 199,000 Btuh Appliance - AC 120 Volts - 60Hz. Remote control - DC 12 Volts Normal Standby Anti -frost protection 0.5 to 6.5 GPM (50 °F rise); MC controller, 96 - 140 °F; BC and BSC controllers, 96 - 120 °F 120 °F (Factory Delault) Natural or Propane - Ensure unit matches gas type it's being installed on. External Only 8 -7/8" ALE COPY 48 Lbs. Natural Gas: 0.82 Natural Gas: 84% Gas supply 3/4" MNPT Cold water inlet 3/4" MNPT Hot water outlet 3/4" MNPT 72 watts 5.5 watts 84 watts Natural Gas or Pro 2532W ° t a % F. TUtM APPRGUED t4P,t( .i U 20O4 AS W i i.0 0.7 to 8.5 GP (WE,ril;rrP D1\ /1Old 3/4" - 1" - 3 -1/2" 4 -3/8" co N CITY OF TIJKWII A Propane: 0.84 FEB 2 3 2004 Propane: 85% PERMIT CENTER REVISION Na M03.2/3 etc. 2532W SP -1 Ignition system Water temperature control Water flow control Minimum/maximum water supply pressure Water Flow Capacity Curves (For 1 to 5 units manifolded in parallel) Safety Devices Remote Controls Remote control cable Clearances from combustibles Clearances from non - combustibles Clearances from Eaves, Porches, Overhangs Clearances from Opening, Window, Door, etc. Min. and Max. gas supply pressure Manifold Gas Pressure (Inches W.C.) Warranty Rinnai Continuum Ilesni ItLt Out 01 Ii t Onlet 00515 Direct electronic ignition Simulation feed forward and feedback Water flow sensor, electronic water control device, and electronic by -pass control device 20 —150 PSI (50 or above is recommended for maximum flow) 45.0 40.0 35.0 E at 30.0 20.0 • • 15.0 —1 Unit 2 Units 3 Units 4 Units 5 Units 25 50 75 100 125 150 AT — Temperature Rise (•F) • Flame failure - Flame rod • Boiling protection - 203 °F • Combustion fan rpm check • Over current - Glass fuse (3 amp) MC -45-4 US BC -45 -4 US or BSC -45-4 Non - polarized two -core cable • Top of heater 12" • Front of heater 24" • Sides of heater 6" • Remaining flame (OHS) • Thermal ('use 264 °F • Automatic frost protection (96 -140 °F range) (96 -120 °F range) www.rinnai.us • Back of heater 0" • Bottom of Heater 12" • Top of heater 2" • Back of heater 0" • Front of heater 24" • Bottom of heater 2" • Sides of heater 1/2" • Installations within RGB -25 Recess Box: Clearances from combustibles to recess box top, bottom, back and sides = 0" Top of heater 36" From Vent Discharge 12" Natural Gas: Min. 6" W.C. Propane Gas: Min. 10" W.C. (NAT) Max. 10.5" W.C. (LPG) Max. 14" W.C. Natural Gas: 3.4" W.C. high fire 0.56" W.C. low fire Propane Gas: 5.1" W.C. high fire 0.88" W.C. low fire Residential: Ten years heat exchanger / five years parts Commercial or Space heating: No Warranty — Use 2532W -C Technical Support: 1- 800 - 621 -9419 Certificate: Project: Issued to: PRODUCTS REU-V2532W-US-(N,P) REU- V2532WC- US -(N,P) DOD 507WD 2002/04/30 CSA INTERNATIONAL FILE COPY Certificate of Com p lance 1307478 (113206) Master Contract: 189893 1384553 Rinnai America Corporation 103 International Drive Peachtree City, GA 30269 USA Attention: James A. Cika MAR : ' 21.104 As [WILD The products listed below are eligible to bear the CSA ll�ax , i%ot� i i x:740 with adjacent indicators 'C' and 'US' US Class No.: 2902 -93 Commercial Heaters (Gas) Water Heater For Outdoor Installation Only Date Issued: Dcc. 11, 2002 Issued by: Robert Loria Authorized by: George Gruss Operations Manager CITY OF TUIWIIIA APPROVED Maximum Minimum Electric Input Input Storage Model Number Rating Rating Rating Capacity Altitude For Use With Natural and Liquefied Petroleum Gases Instantaneous Water Heater for Water Heating and Spacing Heating REVIS1OV NO,_ t Trade Name: RINNAI CONTINUUM 199,000 15,000 199,000 15,000 RECEIVED r 17 f A FEB 2 3 2004 PERMIT CENTER The 'C' and 'US' indicators adjacent to the CSA Mark signify that the product has been evaluated to the applicable CSA and ANSUUL Standards, for use in Canada and the U.S., respectively. This 'US' indicator includes products eligible to bear the'NRTL' indicator. NRTL, i.e. National Recognized Testing Laboratory, is a designation granted by the U.S. Occupational Safety and Health Administration (OSHA) to laboratories which have been recognized to perform certification to U.S. Standards. CSA INTERNATIONAL Certificate: 1307478 Master Contract: 189893 Project: 1384553 PRODUCTS Class No.: 2902 - 13 Commercial Heaters (Gas) Water Heater For Outdoor Installation Only Maximum Minimum Electric Input Input Storage Date: Dec. 11, 2002 Model Number Rating Rating Rating Capacity Altitude For Use With Natural and Propane Gases Instantaneous Water Heater for Water Heating and Heating Trade Name: RINNAI CONTINUUM REU- V2532W- US -(N,P) B 199,000 15,000 N B 179,100 13,500 H REU- V2532WC- US -(N,P) B 199,000 15,000 N B 179,100 13,500 H APPLICABLE REQUIREMENTS ANSI Z21.10.3 - 2001 •CSA 4.3 - 2001, MARKINGS Gas Water Heaters, Volume III Gas Fired Automatic Storage Type Water Heaters with Inputs above than 75,000 BTUH, Circulating and Instantaneous All markings and printed instructions are in compliance with the above mentioned requirements. Samples are contained in the main certification report. DOD 507 W D 2002/04/30 05A INTERNATIONAL Supplement to Certificate of Compliance Certificate: 1307478 (113206) Master Contract: 189893 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 1384553 Dec. 11, 2002 Changed NGK flame sensor to Teikoku Tsushin and corrected drawings per mfr.'s 10/17/02 letter. Replaced drawing Nos. 0000 (03,04,06,07,12,13,40,43,52, 54). 1343789 2002 -09 -16 Authorized recess box for outdoor water heater. 1307478 • 2002 -06 -24 Original Certification. DOD 507WD 2002/04/30 Model number series REU- V2532W(C) -US APPLICABLE REOUIREMENTS ANSI Z21.10.3 2001•CSA 4.3 -2001 y CSA INTERNATIONAL Edition 1: 2002- 06 -24; Project 1307478 - Cleveland Issued by Alberto Nieves Editioti.2: 2002- 09 -16; Project 1343789 — Cleveland Issued by Alberto Nieves Edition 3: Dec. 11, 2002; Project 1384553 - Cleveland Issued by Robert Loria Contents: Certificate of Compliance - Page 1 to 2 Supplement to Certificate of Compliance — Page 1 Description and Tests — Pages 1 to 6 Drawings- Markings- Instructions — Pages 001 to 065 Class No.: 2902 -93 Commercial Heaters (Gas) Water Heater Class No.: 2902 - 13 For Outdoor Installation Only MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 Gas Water Heaters, Volume III Gas Fired Automatic Storage Type Water Heaters with Inputs above than 75,000 BTUH, Circulating and Instantaneous • The test report shall not be reproduced, except in full, without the approval of CSA International. 8501 E. Pleasant Valley Road, Cleveland, OH, U.S.A. 44131 -5575 Telephone: 216.524.4990 1.800.463.6727 Fax: 216. 642.3463 www.csa- Internatlonal.org Descriptive and Test Report MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 13 845 53 Page No: 2 Date Issued: Dec: 11, 2002 MARKINGS All markings and printed instructions are in compliance with the above mentioned requirements. Samples are contained in the main certification report. ALTERATIONS New Report no changes were required FACTORY TESTS Factory test to be in accordance with Part III of the applicable requirements detailed in the Certificate of Compliance TESTS See Main archive file for details of testing MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 Character Description MODEL NUMBER BREAKDOWN R Rinnai E Export U Water Heater (U- wakashiki in Japanese) ✓ Project Number 25 Max Capacity (liter /min) at 25° C rise 32 Project Number W Outside Wall Installation C Commercial US American and Canadian Specification N Natural Gas P Liquefied Petroleum Gas Left Side: 6 inches Right Side: 6 inches Rear: 0 inch Top: 12" Floor: 24" Manifold Pressure Natural Gas Liquefied Petroleum/ Propane Gas Minimum Inlet Pressure Natural Gas Liquefied Petroleum/ Propane Gas Maximum Inlet Pressure Natural Gas Propane Gas Max Rate 3.4 inches w.c. 5.1 inches w.c. 6.0 inches w.c. 10.0 inches w.c. 10.5 inches w.c. 14.0 inches w.c. CLEARANCES OPERATING PRESSURES Min Rate .56 inches w.c. .88 inches w.c. ELECTRICAL RATING 120 volts 3 Amps 60 Hertz 1 Phase Page No: 3 Date Issued: Dec. 11, 2002 z W ' 6 D U O to U) 9 _ H • tL W O: g Q. to 3 ' W. z �. O' z W U • 0 0) O t-' W u J le) z H =I . O1-. z MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 Read columns vertically for complete assemblies Type of Mfr. of Model Size of Control Control Control Number Natural Propane Combination Rinnai Scilci Control Ignitor(s) NGK Manual Valve Jomar GAS CONTROL ASSEMBLIES Electronic Ignition Systems C36E -41 -S 1173 -120 T- 20(3,4) Page No: 4 Date Issued: Dec. 11, 2002 Ignition R. B. Controls 11I -189 x x Module : Flame Teikoku Tsushin AH41 - 216 x x Sensors 3/4 3/4 Zi 00 W W ' , co u- W o u- Q ' O W O 0 ' UI 0 :0 l- W Ui 0 F., Z • MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 COMBUSTION AIR MOTOR: Ratings Manufacturer Model RPM Amp Volts HZ Phase Shinano Kenshi Cop H89 262 - CW 4,320 Hi. .9 35 60 1 1,920 Low .3 14 60 1 COMBUSTION AIR BLOWER WHEEL(S) AND BLOWER HOUSING(S): Blower Wheel Blower Wheel Blower Size No. Housing Manufacturer Model No. L X Dia. (in.) Blades Mfr. Size(in.) Nisshin Bou H89 - 263 -CW 1.57 IN. L. x 3.74in. Dia. 63 Tekuno Parts 5.19 TRANSFORMERS: Manufacturer Model , . Ratings Class Tamura Seisakusho ET -281 120 VAC E(UL 1411) LIMIT SWITCH(ES): Manufacturer Model Type Setting Size(in) Nihon GT BU129 -824 -2 NC BiMetal 194 °F. WIRE AND CONDUIT: Manufacturer Sumitomo Hitachi ELECTRICAL EQUIPMENT Page No: 5 Date Issued: Dec. 11, 2002 Voltage Temperature Gage Ratings Ratings Application 18 AWG 600V 221 °F UL 1015 20 -24 AWG 300V 221 °F UL 1015 RELAY: Manufacturer Model No. Location Application Omron Corp. PCB UL 41515 • re 2 . J U o 0: N • W W =. J � CO u_ W • Q. � W, 1— 0- Z 1—' W uj D. N 0 I—. W W I—V•. tL P — 0. . z. Z 001 — 002 Unit Photograph Details 003 Unit Outer Dimension Details 004 Unit Cut -away Diagram Details 005 Schematic Component Diagram Details 006 Casing assembly Details 007 — 009 Unit Panel Details 010 Wall Installation Bracket Details 011 Heat Protection Plate Details 012 Heat Exchanger Assembly Details . 013 Manifold Assembly Details • 2 — 015 Burner Unit Details • 016 Damper Details 017 — 026 Combustion Chamber Details 027 Conformable Window Details 028 Front Scaling Packing Details 029. Front Panel Packing Side Details 030 — 034 Ignition System Details 035 High Tension Cord Details 036 Water Filter Assembly Details 037 Actuator Assembly Details 038 Gas Connection Details di 039 Lower Packing Details 040 Duct Assembly Details 041 Duct Casing Details 042 Upper Packing Details 043 — 044 Flue Outlet Details 045 P.C.B Details 046 — 049 Blower Motor Assembly Details 050 Transformer Details 051 Over Heat Switch Details 052 —053 Water Inlet & Outlet Component Details 054 — 055 Wiring Diagram Details 056 — 058a Marking 059 Installation Instruction 060 Commercial Installation Instruction 061 T/S Basic Operation Details 062 — 065 Addenda to Installation Manuals MASTER CONTRACT: 189893 REPORT: 1307478 PROJECT: 1384553 PAGE NO. DESCRIPTION Manufacturers tolerances have not been verified. CSA International DRAWING - MARKING - INSTRUCTION INDEX l'age No: 6 Date Issued: Dec. 11, 2002 3 va ; 7 IN T Type of Appliance Operation Exhaust system Rinnai model number Minimum/Maximum gas rate (Input Btuh) Electrical Electrical consumption Hot water capacity Temperature range (with remote) Temperature (without remote) Approved gas types Installation Dimensions Rinnai Weight Energy Factor Thermal Efficiency Service Connections EGR IT — .71711=1•14. FILE COPY 13-3/4" 171 • f low, Check agrovg are Temperature controlled, continuous ow,.gas.,96 fro em- al With or without remote controls, mounted in kitchen, bitlitlipm, et Direct vent, forced combustion REU-2532W-C-US 15,000 BTU's - 199,000 Btuh Appliance - AC 120 Volts - 60Hz. Remote control - DC 12 Volts Normal Standby Anti-frost protection 0.5 to 6.5 GPM (50 rise); MCC controller 96 - 180°F 140°F (Factory Default) Natural or Propane - Ensure unit matches gas type it's being installed on. External Only L rf 8-7/8" L) L.r) • 48 Lbs. Natural Gas: 0.82 Natural Gas: 84% Gas supply 3/4" MNPT Cold water inlet 3/4" MNPT Hot water outlet 3/4" MNPT REVISION NO, SP-1 1•405•21 I I' 72 watts 5.5 watts 84 watts 3 " Natural Gas an&Pronnn APPRovED MAR Q 2.004 AS WALD 0.7 to 8.5 GPMBatiigt;oDIV • • • 0 3 ••• • 3/4" - - 3-1/2" 4-3/8" c■I Propane: 0.84 Propane: 85% PFCEIVED " "1KWIl A FL H 1. 3 2004 CENTER Ignition system Water temperature control Water flow control Minimum/maximum water supply pressure Water Flow Capacity Curves (For 1 to 5 units manifolded in parallel) Safety Devices Remote Control Remote control cable Clearances from combustibles Clearances from non - combustibles Clearances from Eaves, Porches, Overhangs Clearances from Opening, Window, Door, etc. Min. and Max. gas supply pressure Manifold Gas Pressure (Inches W.C.) Warranty Rinnai www.rinnaieus Direct electronic ignition Simulation feed forward and feedback Water flow sensor, electronic water control device, and electronic by -pass control device 20 — 150 PSI (50 or above is recommended for maximum flow) g 30.0 ce 25.0 s 20.0 40.0 35.0 0 45.0 3 15.0 10.0 5.0 0.0 0 —1 Unit 2 Units 3 Units 4 Units 5 Units 25 50 75 100 125 150 AT — Temperature Rise )'F) • Flame failure - Flame rod • Remaining flame (OHS) • Boiling protection - 203 °F • Thermal fuse 264 °F • Combustion fan rpm check • Automatic frost protection • Over current - Glass fuse (3 amp) MCC -45 -4 US Main Control (96 -180 °F range) Non - polarized two -core cable • Top of heater 12" • Front of heater 24" • Sides of heater 6" • Back of heater 0" • Bottom of Heater 12" • Top of heater 2" • Back of heater 0" • Front of heater 24" • Bottom of heater 2" • Sides of heater 1/2" • Installations within RGB -25 Recess Box: Clearances from combustibles to recess box top, bottom, back and sides = 0" Top of heater 36" From Vent Discharge 12" Natural Gas: Min. 6" W.C. Propane Gas: Min. 10" W.C. (NAT) Max. 10.5" W.C. (LPG) Max. 14" W.C. Natural Gas: 3.4" W.C. high fire 0.56" W.C. low fire Propane Gas: 5.1" W.C. high fire 0.88" W.C. low fire Five years heat exchanger / five years parts Technical Support: 1- 800 -621 -9419 10 -03 -2005 MICHAEL CLAUSEN 4402 S 164 ST TUKWILA WA 98188 RE: Permit No. M03 -213 4402 S 164 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 11/11/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, )4 4 C ifer Marshall, Permit Technician xc: Permit File No. M03 -213 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 May 23, 2005 Ms. Diana Clausen 4402 South 164 Street Tukwila, WA 98188 RE: Request for Extension — Permit No. M03 - 213 — 4402 South 164 Street Dear Ms. Clausen: This letter is in response to your written request for an extension to Permit No. M03 -213. Based on the information received, the City of Tukwila Building Division will be extending your permit to November 11, 2005. Please be advised that this will be the only extension granted for this project and no further notice will be given prior to the expiration date. A new permit and associated fees will be required after the above -noted expiration date. If you should have any questions, please contact our office at (206) 431 -3670. Robert Benedicto Building Official /sks File: Permit No. M03 -213 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director sks Page I T:\Links\Docs\M03- 213\M03 -213 - Extension Approval.doc 05/23/2005 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Dtoff Pf -7) E1 1- 1Z LAST' t N6? G/7/06 9111141 rwcc rnMB r Ova vvwava B■lL Nwdimt , pwilAkki ( 1AA) M03 0-13 * lAq0 S 1(oL 5T 1 ry, r t cc ./ylo Gvw WAhoitiv) Amcv4-, q\k- Y0.nn/ kit O prv\AM,A3 94014- ,ezvr Gi/- kaow-t/a, IARAAij buctii c&n yr& Wyk/ i\i-tvut tmAAQ4 r Ovvvu awre!) 91Vz .kw f WV Uiw' ovy4 � ' �ro �� Otriv . T o✓vw Oki 1-4-air) of W/) to* fYw `11+e Ciry OF TVT NAY ED Y 1 2 �'ERM CEN CoSi cytA4 5 2005 - 1C) V 4 0005 i2)16*A_ di-(-(0221 ■i4 io(0- 515- 39c, 03 -31 -2005 MICHAEL CLAUSEN 4402 S 164 ST TUKWILA WA 98188 RE: Permit No. M03 -213 4402 S 164 ST TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, Stefania Spencer, Permit Technician xc: Permit File No. M03 -213 Bob Benedicto, Building Official City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/14/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 January 4, 2005 Mr. Michael Clausen 4402 South 164 Street Tukwila, WA 98188 RE: Letter of Incomplete Application # 1 to Revision #2 Development Permit Application M03 -213 Clausen Residence — 4402 South 164 Street Dear Michael: Enclosures File: Permit File No. M03 -213 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you that your revision received at the City of Tukwila Permit Center on December 27, 2004, is determined to be incomplete. Before your revision can continue the plan review process the following items need to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have questions concerning the following: 1. Provide mechanical equipment info sheet. 2. Provide the house mechanical drawings for new heating system installation. 3. Include energy calculations. Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Sincerely, Stefania Spencer Permit Technician 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431.3665 11 -02 -2004 MICHAEL CLAUSEN 4402 S 164 ST TUKWILA WA 98188 RE: Permit No. M03 -213 4402 S 164 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Sincerely, Stefania Spencer, Permit Technician City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writinM and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 12/26/2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Qilc GGc.� xc: Permit File No. M03 -213 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 June 14, 2004 Michael Clausen 4402 South 164th Street Tukwila, WA 98188 Dear Permit Holder: Sincerely, City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Permit Application No. M03 -213 4402 South 164th Street In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to July 20, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Stefania Spencer Permit Technician Xc: Permit File No. M03 -213 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206.431.3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M03 -213 PROJECT NAME: CLAUSEN RESIDENCE SITE ADDRESS: 4402 SOUTH 164 STREET DATE: 01 -18 -05 Original Plan Submittal X Response to Incomplete Letter # 1 TO Response to Correction Letter # X Revision # 2 after /fie permit is issued DEPARTMENTS: or Buildirl O di ision � � Public Works ❑ Fire Prevention ❑ Planning Division Structural ❑ Permit Coordinator DETERMIN N OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01 -20 -05 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS StING: Please Route Lj Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02 -17 -05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip,doc 2 -28 -02 PERMFF COORD COPY City of Tukwila REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I / (7 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # • Revision # 2 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: CLAUSEN RESIDENCE Project Address: 4402 SOUTH 164 STREET A5 -J �Opcc Contact Person: Michael Clausen Summary of Revision: Aec t 4 . J t c # L agvi P/ S`i 57-1 ( E.v e2 c, u4-4 S -- /ie r Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ( pz .._ Entered in Permits Plus on , ✓ 19 • 09 \ applications \forms - applications on linc\rcvision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southccnter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www,ci.tukwila. Plan Check/Permit Number: M03 -213 TO CoSS Steven M. Mullet, Mayor Steve Lancaster, Director Phone Number: LIZ S— f; 90 -- 380 RECEIVED CITY OF TUKWILA JAN 1 8 2005 PERMIT CENTER • } ACTIVITY NUMBER: M03 -213 PROJECT NAME: CLAUSEN RESIDENCE SITE ADDRESS: 4402 SOUTH 164 STREET Original Plan Submittal Response to Correction Letter # DATE: 12 -28 -04 Response to Incomplete Letter # X Revision # 2 e before permit is issued DEPARTM NTS: Buil in Di A 1 0 °1 1 � I I ,�I,p • ' ' Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator X DETERMINATION OF COMPLETENESS: (Tues., Th rs.) Complete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: l"5 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg If Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete PERMIT COORD COPY DUE DATE: 12 -30 -04 Not Applicable ❑ DUE DATE: 01 -27 -05 DATE: Date: /Z - 08 - Zco 1 AND e MOST FA^I City of Tukwila \ applications \torms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tulovila.wa.us w177-1 R rt'Jt -• Plan ChecWPermit Number: EAS ' r '' IL -L /-6.4 le4 E Pci r (^) POP-Z5 1r 77 Steven M. Mallet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # K r Revision # � after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: CL- AuSC,i Psesr 0E-JCS Project Address: c/go z S /(p S Contact Person: - irks oN) E2oorc Phone Number: cf 2S u 90 - 380V Summary of Revision: CNArvc.p( :� F12.0F12.0/-1 Ut Fo2CED ,qt(Z [(EAT defop -(C (N R o2 KEA (N S , - 6^'i i kW/al..) rc... Hopi Sy icon. 71''t. Pw0P -- 1-(0 2A eo ro 2S Tor. Ic'r_cb 2 JRec:".•-, S . / 57Eit . 6A of tiC x/-177-1 I li f -/frte Ft cM-I C F A/6AT , es A « - (ArrilkE 4-' n Ir X ( RECEIVED CITY OF TI IKWII A DEC 2 8 2004 PERMIT CENTER E4c E( 13 . D--t 7v ? Fe- I—► /14ASTF& / 3 4 T7 - ( 7 2—) A T 7 ^ - , / -- — F o R n 4 , 3 , ( , ) Rc.002 - l r1Th(k S t•' l- V" �- r Orevi' , A4 FK/4Au5 r— BA7?- 1RcxD.. -. a- S / 1 /, .,��,‘. Da .. tac, r FAeo S 1/vr t O iE.E0 A- 0 rc 7 - r•,.t S W IT wt L.L Cys -E_ 7396.1.. o,.) Pic A, ?er 771/ Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: c ir Entered in Permits Plus on / : 8 - C • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M03 -213 PROJECT NAME: CLAUSEN RESIDENCE SITE ADDRESS: 4402 S 161" STREET Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after DATE: 02 -23 -04 /before permit is issued DEPARTMENTS: MSI 44. 2- -O Building Division Fire Prevention Q Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -24 -04 Complete E6 Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RROTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03 -23 -04 PP ❑ Approved Not App Approved A roved with Conditions ]� Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 PERMIT COORD COPY City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1-013 ZZ j 1 nn (, Plan Check/Permit Number: / '' O 3 - 2 / 3 Response to Incomplete Letter # 0 Response to Correction Letter # r id Revision # ! after Permit is Issued [] Revision requested by a City Building Inspector or Plans Examiner Project Name: ( Re.-s Project Address: We? S /( rn Sr 77, e 1_4,4 Contact Person: Phone Number: 4Z V ' 890 — 30 V Summary of Revision: No-r (.0 Gels FUR- niAt2,r 1 A s >� C '(-I L.) ivic /.0 7;FlS 4 . -Ti r-EQ S og# c -s r -. Ri f7-i1zcort w L. L._ `IAv£ I✓Lt"(,7 .iC I. / c7C�I /7r, L)P5;7 / 1 ; o Z))OF 3 WALL /.Jj4 I Ai 1 A CJ.-+ ; r -1 c)u S FLOC) (:vA ell7D2 I/1), L__ (C US E) TZ) SOP PC. I k r t - 7E Pa- Pi -c02- /')!6 % A 6 o.- I) co...)-0,Q4) U S F �v )ivATE r-Icz 7 2. t_t .) P P[ DvrvGS ►r, L ►fiaT 1,11ATEI2 - RecEIVED CITY OF TUKWIL4 FL: f.; ni PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on __23 'O'( 08/06/03 ACTIVITY NUMBER: M03 -213 PROJECT NAME: CLAUSEN RESIDENCE SITE ADDRESS: 4402 SOUTH 164 STREET X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #_ Revision # after /before permit is issued DEPARTMEN S: Buildin i ision Fire Prevention Q Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -16 -03 P Incomplete Complete [► Incom lete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP TUES /THURS RO NG: Please Route L1L1( Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -13 -04 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slIp.doc 2 -28 -02 PERMIT COORD COPY DATE: 12 -15 -03 Not Applicable ❑ DATE: Revision No. Date Received Staff Initials ; I Staff Initials Staff Initials Date .. Issued ( Staff Initials e.Z. I /.z o284 Summary of Revision: I sees' • Summary of R _�� I- �,, 112S, €zs Received By: .€0 eve. �lll I•l�..: , ___ _D- Received By: i ,,, k Revision No. Date Received Staff Initials Date I Issued I Staff Initials I I Summary of Revision: • Received By: PROJECT NAME: �� cam PER/4!1T NO:. - (2i3 Site Address: 4 'i J /G .)4ae - -- Orig...al Issue Date: REVISION LOG Revision • No. Summary of Revision: Revision No. Revision No. Summary of Revision: Summary of Revision: Date Received Date Received Date Received Staff + Date Initials ( Issued kie 447 . Z24} u/.. ILq.�e t� I Zl e CL . 6..C,e (! Received Bf: ) j I Staff I Initials Staff Initials Received By: Received By: v Date Issued Date Issued (please print) (please print) (please print) (please print) (please print) ' Initials Staff I Initials Staff Initials • : •••••, • • • ••• • • • . . vek • &M ROOKD81 E - • - EF DATE •04 BROOKS DESIGN & BUILD 4050 W LI( SAMMAMISH PKWY NE107 REDMOND WA 98 • • F' \i ti \ » i •\ • " • •'' • '.•!.!•:: : ' Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 5379800600 Address: 4402 S 164 ST TUKW Suite No: Tenant: Name: CLAUSEN RESIDENCE Address: 4402 S 164 ST, TUKWILA WA )..11(", •(", . L ( � i er In `> t',• MECHANICAL PERMIT Owner: Name: MICHAEL CLAUSEN Phone: Address: 4402 S 164TH ST, TUKWILA WA Permit Number: M03 -213 Issue Date: 01/22/2004 Permit Expires On: 07/20/2004 ■Pw Contact Person: Name: MICHAEL CLAUSEN Phone: 206 248 -1024 Address: 4402 S 164 ST, TUKWILA WA WW„/ m..". z Phone: '~ z �w aa � J U CO 0 co w w = e — U) w w Value of Construction: $3,000.00 Fees Collected: $65.00 1 Type of. Fire Protection: AFA Uniform Mechnical Code Edition: 1997 . c m �w z1- -1 Permit Center Authorized Signature: Q■ Date: / Y w I- w I hereby certify that I have read and examined t is permit and know the same to be true and correct. All provisions of law and v 0 ordinances governing this work will be complied with, whether specified herein or not. o o SP- The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws i o regulating constructiop'or the performance of work. I am authorized to sign and obtain this mechanical permit. ~ g R. _ O Date: i 7z ', al U= O ff" Z Contractor: Name: BROOKS DESIGN & BUILD Address: 4050 W LK SAMMAMISH PY NE #107, REDMOND WA Contractor License No: BROOKD981J3 Expiration Date:04 /05/2004 DESCRIPTION OF WORK: REPLACE EXISTING FURNACE WITH NEW FORCED AIR GAS FURNACE. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M03 -213 Printed: 01 -22 -2004 • SECOND FLOOR DEMOLITION PLAN EXISTING 1 x DECKING SmEAR PANEL -SEE SCHEDULE FOR TYPE EXISTING CONCRETE FOUNDATION EXPANSION JOINT 4* CONCRETE Si.Ac RE MOVE- BACK HALF OF EXISTING ROOF INCLUDING E XISTING DORMER REMOVE DOOR REMOVE DOORS EXIST. FLOOR JOISTS 6" C 0 GRADE '"'t Ex . \<_- ' - DENOTES WALLS TO BE REMOVED — SUPPORT EXISTING STRUCTURE DURING DEMOLITION. • SEE FLOOR PLANS FOR HEADER SIZES. • DEMO MAY HAVE TO BE TIMED TO COINCIDE W/ SPECIFIC CONSTRUCTION TASKS. EXISTING MAIN FLOOR WALL EXISTING PONY WALL EXISTING CEDAR SIDING s F 0C ".‘ADS—%: S X11 FOUNDATION DETAIL A2 EXISTING SCALE - 3/4" - FOOTING SCHEDULE MARK Fl F2 MARK SIZE(in) 24 x 24 30 x 30 COLUMN BASE SCHEDULE MANUFACTURER MODEL 80 NO BASE REQ'D --USE (2) SIMPSON TS22 8 SIMPSON A8U44 82 SIMPSON ABU46 83 CUSTOM -3 8 "x5.5x5.5" PLATE w/(2)3 /8x4 "LAGS SEE 10/A5 FOR DETAIL * *INSTALL PER MANUFACTURER ** THICK(in) 12 12 14'± REINFORCEMENT (4)44 EA WAY (5)44 EA WAY UP �� ^t�'•. .; r .,..�� r. 'yam :; -�: .• = —!�� i i L 28'± EX C.-MK; E ?TP-`C FOLNW SON ABOW FOUNDATION PLAN MARK C1 C2 C3 1 I J COLUMN SCHEDULE COLUMN CAP SCHEDULE MARK MANUF. MODEL DESCRIPTION PO NO CAP REQ'D - USE (2)SIMPSON TS22 P1 SIMPSON 8C46 POST CAP P2 CUSTOM - 3/16" STEEL POST CAP W/ (2 S 1 /2" THROUGH BOLTS SEE 11/A6 FOR DETAIL * *INSTALL PER MANUFACTURER ** 14'± SIZE(in) 4x4 4x6 TS2.5x2.5x 1 /4 • MAT' L DF #2 DF #2 STEEL DENOTES EXISTING CONCRETE FOUNDATION CONSTRUCTION DENOTES NEW CONCRETE FOUNDATION CONSTRUCTION DENOTES EXISTING 2x4 FRAMED WALL CONSTRUCTION DENOTES NEW 2x4 FRAMED WALL CONSTRUCTION 1117,.271 ALIGN W/ EXISTING WALL ABOVE EPDXY NEW HORIZONTAL FOOTING REINFORCEMENT INTO' EXIST. FOOTING - EMBED' 7' min_ TYP (2) FOOTINGS I EXISTING MASONRY CI ;MNEY & CONCRETE FOOTING J D(ISTING FOUNDATION -H I w 1 82 Cl F2 I- 18"Wx12*D FOOTINGS 1 r.I_ I __ ALIGN _ W/ DOOR C R.O. ABOVE p SIM I A�,GN W/ DOOR R.O. ABOVE z I- 0 0 14 " D x 12 W KNOCKOUT CI C- DOORS FOR HYDRONIC TUBING. TYPICAL 0 (4) LOCATIONS SiM EPDXY NE* - 1ORIZONTAi FOC7ING REjNr ORCEMEW :VO. + 418"Wx 12"D FOOTING EX•ST. FOOT NC; - EMBED; 7' m;r. TYP • EACI- EN ; II— _ i i f ALIGN NEW FOOTING �~ Ml� WALL ABOVE EPDXY NEW HORIZONTAL FOOTING REINFORCEMENT INTO DCIST. FOOTING - EMBED 7' min.TYPOEACHEND NORTH 5` 0' 5' PVVV4 SCALE - 1/4 = 1' - 0' HOLD DOWN SCHEDULE MARK MANUFACTURER MODEL * *INSTALL PER MANUFACTURER ** - H cD N SIMPSON SIMPSON SIMPSON SIMPSON SIMPSON SIMPSON SIMPSON SIMPSON ALIGN WITH CL NEW 2ND STORY WALL ABOVE ALIGN WITH CL RIDGE ABOVE MST27 MST37 MST48 MST60 ITT131 HTT 1 6 HTT22 HD15 81 Cl CONNECTION TYPE LOAD ALLOkED WOOD TO WOOD 276C. WOOD TO WOOD WOOD TO WOOD WOOD TO WOOD BOLT TO CONCRETE -NAIL TO STUD BOLT TO CONCRETE-NAIL TO STUD BOLT TO CONCRETE -NAIL TO STUD BOLT TO CONCRETE -BOLT TO STUD � o 3 � z Q 3 rI frnfor /!I /.W.M////W[/I/N /011160///I/Y~ ===== I //// I/M. FA! .1.01111111.101..l. 40 MP' ..w�+t..++..�.. <t-T3 14'± i L a2 381,t, 4460 580C 2185 3480 5250 15303 28'± C2 X S A.; EN - q'y FOUNDAT -ON ABOVE FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. By Date Permit No. i I BASEMENT FLOOR PLAN V3 14'± MARK L • ,SHEAR WALL SCHEDULE CONSTRUCTION DESCRIPTION 1/2" PLYWOOD W /10d NAILS 0 2 "O.C. ANQHQRAGE: (3) 16d 0 5 "O.C. OR 3/4" BOLTS 0 24" O.C. W/ 2x2x3/16" BEARING PLATES. USE 3x MEMBERS O ADJOINING PANEL EDGES. 1/2" PLYWOOD W/1 0d NAILS O 3 "O.C. ANCHORAQE: (2) 16d 0 5 "O.C. OR 5/8" BOLTS 0 24" O.C. W/ 2x2x3/16" BEARING PLATES. USE 3x MEMBERS O ADJOINING PANEL EDGES. 1/2" PLYWOOD W /10d NAILS 0 6" O.C. ANCHQRAGL: (2) 16d 0 10" O.C. OR 5/8" BOLTS 0 32" O.C. W/ 2x2x3/16" BEARING PLATES. C � 1/2" PLYWOOD, (2) SIDES, W /10d NAILS O 4" O.C. ANCHQRAC : (3) 16d 0 5" 0.C. OR 3/4" BOLTS 0 24" O.C. W/ 2x2x3/16" BEARING PLATES. USE 3x MEMBERS 0 ADJOINING PANEL EDGES. STORAGE LAUNDRY (2) ON— DEMAND WATER HEATERS SHOP 4" SLAB H Cl ALIGN W/ DOOR 1 R.O. ABOVE UP 2- 6x6 -8/ i MUSIC .• SLAB AQ b /!/j dt# I B1 Cl B1 Cl I OLP AF • ! E PERMIT HEL? JI: B FOR: 0 ' r CHA '.r. SAL VELECTR CAL PLUMBING GAS PI ?iN3 CITY OF TU KWILA 1 L14'.J;SI WATER GAS r; • 1 81 ALIGN W /_DOOR ROUGH Cl OPENING ABOVE ALIGN W/ DOOR ROUGH OPENING ABOVE /ALIGN W WINDOW ROUGH OPENING ABOVE AL GN WITH CL RIDGE ABOVE A4.IGN NEW WALL W/ WALL ABOVE ALTERNATE WATER I HEATER LOCATIONS AL;GN w/ WINDOW ROUGH OPENING ABOVE EXISTING 1 PONY WALL 4 111111k ORTH 5' 0' 5' PVT/WV SCALE - 1/4• at 1' - 0• /103 -223 r I. iu I 0 IU C3 0 au re Q z 0 0 0 z 4 Z w Cf) V <<iE i•• - +.e-.. $ 5a-- - •: DECEMBER 3, 2003 REVISION 1.0 FEBRUARY 19, 2004 • W V Z LU to LU oC � OC H u) O an A2.1 S