Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M02-007 - BOEING #9-50
," ,••• ' . '''.4111111411 Boeing 9-50 M02-007 Value of Construction: Signature: Print Name: doc: Mech }' y City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003400018 Permit Number: MO2 -007 Address: 9725 EAST MARGINAL WY S TUKW Issue Date: 01/22/2002 Suite No: Permit Expires On: 07/21/2002 Tenant: Name: BOEING #9 -50 Address: 9725 EAST MARGINAL WY S, TUKWILA, WA Owner: Name: BOEING Address: PO BOX 3707 - M/S 1 F -09, SEATTLE WA Contact Person: Name: KAREN PASCOAL Address: 20109 144 AVE NE, WOODINVILLE, WA Contractor: Name: JOHANSEN MECHANICAL INC. Address: P.O. BOX 1768, WOODINVILLE, WA Contractor License No: JOHANMI173PK DESCRIPTION OF WORK: RE -HANG EXISTING HVAC UNIT. NEW DUCTWORK PER PLANS. Type of Fire Protection: Uniform Mechnical Code Edition: Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. a MECHANICAL PERMIT $40,000.00 Fees Collected: MO2 -007 Phone: Phone: 425 -481 -2266 Phone: 425 481 -2266 Expiration Date: 02/01/2002 $69.13 1997 Date: Date: l L" 2. 0 2 - This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 01 -22 -2002 t.a. ,_,hr: ACTIVITY NUMBER: MO2 -007 DATE: 01 -16 -02 PROJECT NAME: Boeing 9 -50 Walls SITE ADDRESS: 9725 East Marginal Wy S SUITE # X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Awl ) -11- - C Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (4 weeks) Approved \PRROUTE.DOC 5/99 PERMi i CPY PLAN REVIEW /ROUTING SLIP CORRECTION DETERMINATION: Fire retention Structural Incomplete n Not Applicable Structural Review Required Approved with Conditions Approved I Approved with Conditions REVIEWER'S INITIALS: REVIEWER'S INITIALS: PERMIT COORD COPY Planning Division Permit Coordinator No further Review Required DUE DATE 02 -14 -02 Not Approved (attach comments) DUE DATE: 01-17-02 Not Approved (attach comments) DATE: DUE DATE DATE: ACTIVITY NUMBER: MO2 -007 DATE: 01 -16 -02 PROJECT NAME: Boeing 9 -50 Walls SITE ADDRESS: 9725 East Marginal Wy S SUITE # X Original. Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Please Route X n Complete Incomplete Comments: TUES /THURS ROUTING: REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP Structural APPROVALS OR CORRECTIONS: (4 weeks) Approved n Approved ith Condition REVIEWER'S INITIALS: DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: \PRROUTE.DOC 5/99 Fire Prevention Structural Review Required n No further Revie Req red DATE: Planning Division Permit Coordinator DUE DATE: 01-17-02 Not Applicable DUE DATE 02 -14 -02 Not Approved (att ch co ments) DATE: 11 ACTIVITY NUMBER: MO2 -007 PROJECT NAME: Boeing 9 -50 Walls SITE ADDRESS: 9725 East Marginal Wy S DATE: 01 -16 -02 SUITE # ^. Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works n n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Structural Review Required x REVIEWER'S INITIALS: l,__`53 APPROVALS OR CORRECTIONS: (4 weeks) Approved n Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 01-17-02 Not Applicable No further Review Required DATE: ( 1 (O 2- DUE DATE 02 -14 -02 Not Approved (attach comments) I I DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Project Name /Tenant: I Qoe;,i. - SO (.(�a $ Value of Mechanical Equipment: 4 40, COO Tax Parcel Number: DOO 3 q OP Q f 6 Phone: ( ) Site Address : / q 7 '?s > Qs4 MA rai.u�,$ a, City State /Zip: S - Ckw;Iin 60A- Property Owner: � OL ^S Street A ress U C C 1\ ox 3 - /lA /S j ( =off' City State/Zip: Sealt e 119A Fax II: ( Contractor: // ,,nn� � J / �/na,,, ce...i Ades 4., ;Ca/ ANC Phone: ( l/Z S ) L 6 D I - �a 6 Street Address: Cit� State/Zip: loq - / 11 ' 1 AJL= h U 0;4 W4 9`6072 Fax #: (4 • ) ‘. (q6 . ~ 6V3 Contact Person: r Phone: ( c(ZS ) Street Address: d t a 4 -- / �y f& City S State/Zip: Aim Al 1 .,,li,,:lit 4111 ffc.72 Fax #: ( ) vZ �- �� 6 �� �3 3 '. :BUILDING ;0, ER'OR }AU N' Signature: Date application accepted: . , 1/2/99 mach permlt.doc CITY OF T( `WILA Permit Center 6300 Southcqnter Boulevard, Suite 100 Tukwila, WA 1 98188 (206) 431- 300 echanical Permit A • plication Application and plans must be complete in order to be accepted for plan review. Appjlications will not be accepted through the mail or facsimile. •_ . , ..: ; MEC1=1p1V1, Al ,pl;' 201tiREVIEW AND A6 REc ..ESTEp; (TO:BEFILLED OUT'BY,•APpLIcAN Description of work to be done (please be specific): (de_ - iia c Pi( ; / — /(19 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidayit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAW READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR,THIS,•PERMIT. City /State/Zip: Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application expires: '7-1ro t t« Application taken by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. r 11/2/99 uilscp l.doc New Single Family Residence Change -out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of .gas Fireplace Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements Heat loss calculations or Form H -6. Equipment specifications. Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water . heaters or vents being installed or replaced. Parcel No.: 0003400018 Permit Number: MO2 -007 Address: 9725 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 01/16/2002 Tenant: BOEING #9 - Issue Date: 01/22/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (248- 6630). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions r• City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Av,/ J MO2 -007 Date: / c) Printed: 01 -22 -2002 C.ity of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003400018 Permit Number: MO2 -007 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 01/16/2002 Applicant: BOEING #9 -50 Issue Date: Receipt No.: R020000068 Payment Amount: 69.13 Initials: SKS Payment Date: 01/22/2002 10:15 AM User ID: 1165 Balance: $0.00 Payee: JOHANSEN MECHANICAL INC TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt Current Pmts Amount MECHANICAL - NONRES PLAN CHECK - NONRES Type Payment Check 037974 69.13 RECEIPT Method Description Description Account Code 000/322.100 55.30 000/345.830 13.83 2875 01/23 9716 TOTAL 69.1.3 CITY OF TUKWILA RECEIPT Pfd LCD 55.30 P1 DCD 13.83 CI -IECI; 69.13 Total: 69.13 01/23/02 16 1535 0097 2875 Printed: 01 -22 -2002 Proj 4 ` O Type of Ins coon: ` Ad ress: t, ( . ' � Date called:, .. - Special instructions: Date wanted: a.m. Requester :. Phone: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 il. Approved per applicable codes. fl Corrections required prior to approval. COMMENTS: SC. 4e? S ,644,,, i .��./� >4:2 : -6 7 C y9 L1fez r. ztv ef.:7- (, >7 Inspecto Da 0 $47.0 S EE REQUIRED. Prior to jnspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: R IT NO. 206)431 =3670 •'j • - Project Name Fire Department Needs shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM City of Tukwila 11■•■ 'Now TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM ,S Retain current inspection schedule Approved without correction notice \ Approved with correction notice issued T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. in - Col Address C \ - 1,- c f) ;) S Suite # Date "P r Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 ;0 • • • • „ • • •• • . • • !'" • .4." • : • .• s••••,?.. ,•,•• .• A.'SRONZIDEDY.A3Y ". • • • • • ' • • •'• • • ; • 41'4;;;;V ONS.T.' CONTeI "GENERAB • _... • ' • ' • TA/LENT:OF:LABOR ANO INDUSIKESs=' - • •• • • -., • • 4.: • 3f; i ! d rr4 • 4 *;: • .'" 4 .17W On • • 4.11 tar.4...use4.1 , C'T . ,.., :.' • .;, ' itM-i • '•,:::::::.'; ....,., . .1:::-'' • ., y . ,Zi • • -....-.- : Ai•- - , -4- . -i' . . • '. -' 4?-; C - ',.,...., ...' • ,. ,, .. J01 ' .. iN.: ......e - 7t. f .„3,` . .;, - -,. : 1,1 -:4 .0• 7 ‘," .. ... v '..."'‘...--%, -2 i,' .. - . -- " -- 4.i. ;::- .•. : P ....}343X. -I 17 , .:.-=4::: ; .-.,,, . " .. -....:- . - :A........,,wA -..:. ...: .. • ••0. !-:-.,,...•-•. -,..0........? . 4 .-‘,.... 4s ••,:-:„. , J .. 8 .." - ' '' w..,. , • • •,...4 ,,. ,....y ,.,,,, - ., ..,,...,.• 4 .5 ,li,:i. • r.". ....vq, • y . .'47 ,.. .., 2.,,oly , . - ':".- : ,4, ow „t•-.5.,?:1 TIME" O .. '... ....4 .4. ......, .. • , t. - - r ..'■ • :' . ••••• A. . .. •:., -....,:.- .. ....A ',..,._.,..,......", 4.1 ' ....-....,.;/...",",,..4k4:.,..,.iii.S, ...;,: ' , , .. r • . . • j' ".14' .. 'le •4..' " *Y.. % , ' It.1: .1 *; • ' ' ' • 0, " . , :i# "4 •1 1 9...: • ...... .1 , 1..'..f& t . li ' , • 'ill,. ,.1)- .-.--,-"' • +1 • l' . :45,. 7 1 . • , ....i. .„ • • : ' ::.,.• ,.. • .4f .71 • „,., , . J -4.19 • ....s, — - . ., .'• lic,.....+...t,', ' • • - ,. ., . - O'' '.• . t e ,. ;., _ _ 4. , - , ...1..:11).,i • it ■ LU 6 -Jo 00 co o cow w 0 2 g < W - a I— al Z I-0 Z IJU w 2 D co 0 - 0I— LU t u IL 3 z sl2 0 PERMIT NO.: NI V 7 01 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 2 Pre- construction ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 610 Chimney Installation/All Types ❑ 700 Framing ❑ 1080 Woodstove 1090 Smoke Detector Shut Off 1100 Rough -in Mechanical 1101 Mechanical Equipment/Controls 1102 Mechanical Pip /Duct Insul 1105 Underground Mech Rough -in 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final ❑ 4015 Special -Smoke Control System o 0 ❑ CONDITIONS X 10001 No changes to plans unless approved by Bldg Div ❑ 10002 Plumbing permits shall be obtained through King 10003 Electrical permits obtained through L & I Sir 10005 All permits, insp records & approved plans available 10014 Readily accessible access to roof mounted equipment 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans 10027 Validity of Permit ❑ 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 1004/ Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: SO6 \S FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended /Wall /Floor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig /Cooling Unit/System (qty) Boiler /Compressor to 3 HP/ 100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 0 0 (qty) CD over 10,000 10,,000 0 c tin (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'I Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Plan Reviewer: X�/, \ Date: ( Permit Tech: z_ Date: 1- j g "07/ y: > ><�:� :. ;�x:+�n ��t:!x�n: <r:: >:<: : > < i >r} y t44 ..t. ..: yi '}•::. }'¢'.tY. }::ip;: n:tni'i: ?. } } } }:• }:in: :. .... -. :�r � �•ri ?'.' }S +: ?;i.•f: '•} �il��{k ti :r. vR ::: tY: }:: ti�!'R::? : ........? ...... i•%• }:. Y :•:•:y };::.:• } }:• }:•:•.:•:•... . ::•i: a P uocoris✓ �go , acaA— ga •�gi -a��� Balance Due: $ 0.i3 Need Current Contractor Registration Card: eed to Enter Contractor Information in Sierra: Yes 36\0S■5 c' Yes Z j W QQ J O U N D Lu J = CO LL WO 2 Z � F- O Z F- w w U � O - � F- W W H0 9--O z W U= O~ z NSI ■ n Is- I ii ■S 1M11 M5 24 "0 GA GALV. LONG! DINAL M ICT SLED D UC F F A' S D D 40" X 12" 2 V. 12" L DU T EXTEN TO RUM LO (TY 5) 18 GA 3ALV. . CONCENTRIC REDUCE (typ) � A 5 SMALLER T N 37 "0 RUSKIN , FSD6OV 2" X 32'11 WIITH ELEC. F SE LINES `ND DAMPER ACTUATOR, FLO DU ;T RE DETECTOR. INSTALL WI CTORY FRAME MOUNTI G ANGL S D 20 GA SLEEVE. CSNNECT WARE DAMPER TO 30' ROUND JCT VIA FACTORY T' ' SITIO JCT. 12 "0 x 90° 18 GA GALV. 5 GORE ELL WITH 18" CE LINE RADIUS SLIP CO REPLACE LOWER WINDOW WITH �'W,, 444N1-I LOWER AND MOTORIZED DAMPER BD X17.7' WALL 8x1 DO 8' A.F. 14W 200 1M11 1M 17 180 17.5 OPENIN ACCES I • ni 77:411 i m _ i m r"� 16x24 EX BOTTOM 010" AVE. . 650/1100 CFO (3 TYP) EG / EXISTI<• 7 12 "0 2s GA GALV. LONGITUDINAL SEAM I , . D IST 2" X 45"" DUCT G DUCT WORK ---� EXISTING - 30x 2 SUPPLY GRILLE 1000 CFM (TYP 2) 8/20 32/16 18 "0 x 90° 18 GA 5 GORE ELL WITH 27 LINE RADIUS SLIP CO TITUS #DL20" X DRUM LOUVER, W'H E (TYP 7) CO F.D P.O.0 10' -0" EXISTING 32x16 SUPPLY GRILLE 1000 CFM 4 4k I � 18' 20 GA G` V. 4W LONGITUDINALEAM ALV. " CEN NNECTI 20" X 10 22 GA TO DRUM LOUVER GALV. 12" LONG '- �,�j DUCT EXTENSION t�\� Il (TYP 7) ri=r1 30 "0 20 GA GAL . LONGITUDINAL SEAM DUCT 38 "0 x ° 18 GA GAL L 3 CORE E WITH 45" q LATER o LINE RADIU SLIP CONN (GTIONS (typ 2 ) 30 "0 x 18 GA GALV. M if RED ELL WITH 5 RNING VANES D SLIP _I CONNEC I NS 30 "0 18 GALV. BULLHEAD E WITH . f 5 TURNING ANES AND SLIP CONNVCTIONS EXISTING 1 36" 4 11 10" 1 18 GA GALV. I40/20 TO 30 "0 TRANSITION WITH SLIP CONNECTION 0 ROUND END AND DUCT FLANGE ON RECTANGLE END 9 GA NG ON 1M11 M5 P I Pr 24 "0 20 GA G LONGITUDINAL x TITUS #D 40" X 0 1 ®DUCT GA GALV. DRUM LO VER, W WITH DA PER, 25 II (TYP 5i, 1 - I , md GALV. BEA D ' COUPLING WITH VE. TYPICA ' M ill n N'^ RUSKIN #BD6 32' ACKDRAFT DAMPER. SQUARE DAMPER TO 3 QUCT VIA FACTORY TRP 'OCT. t VER X 32" CONNEC ROUNI ISITION 30 "0 x 90' 18 GA GALV. r 5 GORE ELL WITH 30" CENTE LIN11 RADIUS SLIP CONNECTIOJS I 4 36 "0 20 GA DUCT X 42 "0 x D 3 GORE ELL LINE RADIX' LANGE CON LV EA 20 GA GAL SLEAVE CO PL 4" SLEAVE. TY DUCTS SM`LLE 30 "0 20 GA ALV LONGITUDINAL SEA DUCT AL 45' ITV AN EC 1 1/4" X COMPA ION FOR DU TS FIRST FLOOR HVAC PL 60 "4 1 ALV. LONGITUU ` r.EAM .1 4 DUCT I IMAM 7' GTH. I I J ii- DED WITH HAN 37''0 8 GA GALV. 02" CENTER COMPANION NS (typ 2 ) /4" X 1/8" NGE JOINT RGER THAN 15/19 p 36x18 1170 CFM 10' -0" 24/20 -f -- FUEL TEST 'B DWG 109 -05 TOP OF DUC 11' -0" AFF G 12/8 15/19 1682 CFM 36x18 SUPPLY GRILLE RELOCATED A.H.0 #1 18500 CFM @ 2.5" S.P. 15HP, 480V, 30 "PACE" A -30 0 4505 Ii Ia 1 1 ilk /. M7 32/26 4D / 512 CFM SUPPLY GRILLE VD D TURN I G VANE (TYP.) 36/18 2 CONSTRUCTION NOTES RELOCATE AHU AND MAINT. PLATFORM DUE SOUTH FROM ITS ORIGINAL LOCATION AS PER THE STRUCTURAL DRAWINGS. INSTALL A 42" X 33" TO 60 "W X 48" LONG 18 GA GALV. TRANSITION. CONNECT TO AHU WITH FLEX CONNECTION MEETING SMACNA FIGURE 2 -17 CONSTRUCTION STANDARDS. - INSTALL 60 "0 18 GA GALV. LONGITUDINAL SEAM DUCT WORK WITH 1 1/4" X 1 1/4 X 1/8" THICK COMPANION FLANGE CONNECTIONS. LIMIT DUCT SECTION LENGTH TO A MAXIMUM OF 72" TO MEET GIRTH REINFORCING JOINT REQUIREMENTS. E22>-SUPPORT THE DUCT WORK AS PER DETAIL #1 & #2 ON SHEET M551 AT A MAXIMUM 72" BETWEEN SUPPORTS. PROVIDE LATERAL AND TRANSVERSE SIESMIC BRACING ON THE THE DUCT SUPPORT AS PER DETAIL #3 & #4 ON SHEET M551. © TIE INTO THE 60" SUPPLY DUCT WITH A 30' LATERAL AND ROUTE 30 "0 20 GA GALV. LONGINTUDINAL SEAM DUCT WORK TO. THE NEW REFRIGERATION ROOM. 1/..--SUPPORT THE DUCT WORK AS PER DETAIL #1 & #2 ON SHEET M551 AT A MAXIMUM 120" BETWEEN SUPPORTS. .INSTALL A 60 "0 X 42 "0 X 36' LONG 18 GA GALV. CONCENTRIC REDUCE WITH 1 1/4" X 1 1/4" X 1/8" THICK COMPANION FLANGE CONNECTIONS. INSTALL 42 "0 20 GA GALV. LONGITUDINAL SEAM DUCT WORK WITH 1 1/4" X 1 1/4" X 1/8 " THICK COMPANION FLANGE CONNECTIONS. UMIT DUCT SECTION LENGTH TO A MAXIMUM OF 72" TO MEET GIRTH REINFORCING JOINT REQUIREMENTS. 10 INSTALL (2) 42 0 x 45' 18 GA GALV. 5 GORE ELLS WITH A CENTER LINE RADIUS OF 52" AND COMPANION FLANGE CONNECTIONS TO OFFSET THE DUCT WORK TO MISS EXISTING OBSTRUCTIONS IN THE CEILING SPACE. INSTALL A 42 "0. X 36 "0 X 24" LONG 18 GA GALV. CONCENTRIC RED. WITH 1 1/4" X 1 1/4" X 1/8" COMPANION FLANGE CONNECTIONS ON THE DISCHARGE OF THE ELLS. ® [2:2,- ROUTE 36 "0 20 GA GALT. LONGINTUDINAL SEAM DUCT WORK WITH SLIP CONNECTIONS FROM THE DISCHARGE OF THE 42 "0 TO 36 "W REDUCER. CONNECT DUCTS AND FITTINGS WITH DIAMETES LESS THAN 37" WITH 20 GA GALV. BEADED SLEEVE COUPLINGS WITH 4' SLEEVES. INSTALL A 36"0 X 30 X 24 LONG 18 GA GALV. CONCENTRIC REDUCER WITH SLIP CONNECTIONS. t4 ROUTE 30 "0 20 GA GALT. LONGINTUDINAL SEAM DUCT WORK WITH SLIP CONNECTIONS FROM THE DISCHARGE OF THE 36'0 TO 30 "0 REDUCER. INSTALL A 30 "0 X 24 "0 X 18 LONG 18 GA GALV. CONCENTRIC REDUCER WITH SLIP CONNECTIONS. ROUTE 24 "0 20 GA GALV. LONGINTUDINAL SEAM DUCT WORK WITH SUP CONVECTIONS FROM THE DISCHARGE OF THE 30 "4 TO 24'0 REDUCER. TIE INTO THE SUPPLY DUCT WORK WITH A 40 X 12" 20 GA GALV. 12" LONE LATERAL AND INSTALL A TITOS #DL40X12 DRUM LOUVER WITH DAMPER. BALANCE TO 2500 CFM. INSTALL A 32" X 32" RUSKING #FSDHOV 1 1/2 HOUR COMBINATION SMOKE /FIRE DAMPER WITH ELECTRICE FUSE AND DAMPER ACTUATOR AND DUCT MOUNT SMOKE DECTECTOR. MOUNT IN WALL WITH FACTORY 20 GA GALV DUCT SLEAVE AND MOUNTING ANGLES. ATTACH TO 30 "0 DUCT WITH FACTORY DUCT TRANSITIONS. PROVIDE A 12" SQUARE ACCESS DOOR FOR INSPECTION OF THE NEW FIRE DAMPER. 1g INSTALL A 32" X 32 RUSKING IRON BACKDRAFT DAMPER IMMEDIATELY BEFORE FIRE DAMPEG ATTACH TO 30 "0 DUCT WITH FACTORY DUCT TRANSITIONS. INSTALL A 30 "0 X 90' MITERED ELL WITH (5) TURNING VANES AND ROUTE THE NEW DUCT DOWN TO A BULLHEAD TEE WITH 5) TURNING VANES WITH A BOTTOM OF DUCT ELEV. OF 11' - 8" AFF ROUTE 30 "0 20 GA GALS. LONGINTUDINAL SEAM DUCT WORK WITH SUP CONNECTIONS FROM THE DISCHARGE OF THE 30'0 BULLHEAD TEE. CONNECT DUCTS AND FITTINGS WITH 20 GA GALV. BEADED SLEEVE COUPLINGS WITH 4' SLEEVES. INSTALL A 30 "0 X 90' 18 GO GALV. 5 GORE ELL WITH A CENTER LINE RADIUS OF 30" LINED UP WITH THE CENTER UNE OF THE EXISTING 40' X 20" DUCT. INSTALL A SECOND 30 "0 X 90: 18 GA GALV. 5 GORE ELL WITH A CENTER LINE RADIUS OF 30" ON THE DISCHARGE OF THE FIRST 900 ELL TO LINE UP THE NEW 30 "0 DUCT WITH THE ELEVATION OF THE EXISTING 40' X 20" DUCT. INSTALL A 40" X 20" TO 30 "0 X 36" LONG 18 GA GALV. TRANSWON TO THE EXISTING DUCT. PROVIDE A 12" SQUARE ACCESS DOOR FOR INSPECTION OF THE EXISTING FIRE DAMPER. CONNECT THE NEW TRANSITION TO THE 30 "0 X 45' ELL WITH A 30 "0 18 GA GALV DUCT. INSTALL A 30 "0 X 24 ° 0 X 18" LONG 18 GA GALV. CONCENTRIC REDUCER WITH SLIP CONNECTIONS. FLAG NOTE TWENTY SIX IS NOT USED FLAG NOTE TWENTY SEVEN IS NOT USED FLAG NOTE TWENTY EIGHT IS NOT ' 1 CONSTRUCTION NOTES (CONT.) 29 ROUTE 24 "0 20 GA GALV. LONGINTUDINAL SEAM DUCT WORK. WITH SLIP CONNECTIONS FROM THE DISCHARGE OF THE 30 "W TO 24 "0 REDUCER. INSTALL A 24'0 X 20 "O X 16" LONG 18 GA GALV. CONCENTRIC REDUCER WITH SUP CONNECTIONS 31 ROUTE 20 "0 20 GA GALV. LONGINTUDINAL SEAM DUCT WORK WITH SLIP CONNECTIONS FROM THE DISCHARGE OF THE 24 "0 TO 20'0 REDUCER. INSTALL A 20 "0 X 18 "0 X 12" LONG 18 GA GALV CONCENTRIC REDUCER WITH SLIP CONNECTIONS. ROUTE 18 "0 20 GA GALV. LONGINTUDINAL SEAM DUCT WORK WITH SLIP CONNECTIONS FROM THE DISCHARGE OF THE 20 "0 TO 18 "0 REDUCER. INSTALL A 18 "0 X 12 "0 X 12" LONG 18 GA GALS. CONCENTRIC REDUCER WITH SUP CONNECTIONS. ROUTE 12 "0 20 GA GALV. LONGINTUDINAL SEAM DUCT WORK WITH SLIP CONNECTIONS FROM THE DISCHARGE OF THE 18 "0 TO 12 "0 REDUCER. TIE INTO THE SUPPLY DUCT WORK WITH A 20" X 10" 22 GA - GALV. 12" LONG LATERAL AND INSTALL A TITUS #D-20X10 DRUM LOUVER WITH DAMPER. BALANCE TO 430 CFM. BALANCE ONE EXISTING 32" X 16" GRILLE AND TWO EXISTING • 30" X 12" GRILLES TO 1000 CFM EACH. CAP THE END OF EACH NEW DUCT RUN AND THE OPEN END OF THE EXISTING DUCT WORK WITH 18 GA GALV. CAPS. FILL THE EXISTING OPENING IN THE 12 THICK SHEAR PANEL WITH TWO TRACKS OF 3 5/8" X 18 GA GALS. METAL STUDS ®16" ON CENTER. ATTACH A MIN. OF (2) LAYERS OF TYPE "X" GWB TO EACH TRACK OF STUDS FLUSH WITH EACH SIDE OF THE SHEAR PANEL FILL VOID BETWEEN THE TRACKS OF STUDS WITH FIBERGLASS INSULATION. THE COMPLETED • ASSEMBLY MUST MEET A 2 HR UL 411. RATING. PAINT THE TO MATCH SHEAR PANEL NOTE: 1). ALL WORK TO BE COMPLETED IN COMPLIANCE WITH THE 1997 UNIFORM MECHANICAL CODE AND ALL APPLICABLE CITY OF TUKWILA ORDINANCES. 2) ALL NEW DUCT WORK WILL BE PANTED WHITE TO MATCH THE EXISTING CEILING COLOR. N 0 el By Date - (��- Permit No. 1M1D I ■ CURRENT REVISION 702415 -02 SHEET j/ SYMBOL B 1M12 DATE 16- NOV -01 --- _ENHECK CW13- 180 -10, :0 (1725/1140) MOTOR, -_ _ 1 "sp (1180 FAN RPM), .5 "sp (780 FAN RPM) REVISIO I MYLAR TO CAD DWG #109- 050 - 4506 -M1 702416 -01 DLD HU 702'15 -02 COP 5260 GEM @ 1/8 "" 1 5x BY APPROVED CCSI RWS WALL MOUNTED EXHAUST FAN W /BACKDRAFT DAMPERS @ APPROX 20' A.F.F. DATE 12.10.00 1031 01 RWS •Ic NOD -01 SYM LABELED "EMERG EXHAUST FAN" REVISION APPROVED SCALE: 1/8" 1' -0" DATE Q /Na° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT: DRAWN S. 2AROUDNY CHECKED SL ONG1."REH DATE SL CHECKED ROOF EXHAUSTER, SEE DETAIL 1M11 1M506 BACKDRAFT DAMPER, SEE DETAIL DATE 7.24.85 7.24.85 7.24.85 TITLE 1M1 SUBTITLE FIRST FLOOR HVAC PLAN LEGEND GENERAL NOTES F 'ENCE DRAWINGS I understand that the Plan Check approvals are suojec( to en and omissions and approval of Oars does not authorize the violation of any adopted code or ordinance. Receipt of con - tractor's copy of approved plans acknowledged. PERNIIT D FOR: r�L [WEL CFI- ' i:"C TG I CITY OF TUR"i3 LA BUILDING DIVISION Mo;t oo7 '5 KEY PLAN SCALE: NONE 111 CITY Of TAKWILR APPROVED JAN 1 A DD`32 flFl `TUG DP/7s - N CITY OF TUKWILA JAN 16 2002 PERMIT CENTER 3 "4 STEAM SUPPLY (NEW) ♦ ROOF EL. 40' -0" ) l lJ B -LINE B -22A, DBL STRUT l L ( 3 l (,1 `$ l lJ lJ 1, (..,_ — — — i �— -- 1"-.-„,\-\--- I \ /— __ ! � = fi 5 = 67 • 1 j ' ' -- Cr 10 10 0 9'- 1— \- BOTTOM OF N -S BEAM 18 GA GALV. CAP ON "0 DUCT 10 0" "4 LONGITUDINAL 18 20 GA SEAM GALV. DUCT — R.. - { 7 "4 x 90' 11VGA GALV, MITERED ELL N -S BEAM \,...‘" n U O O ,' a e O O o O o O 24 ' oo .0. -0 oa oo 18 GA GALV. CONCENTRIC REDUCER (typ) O ' i N 1 — MI \ WITH S TURNING VANES AND SLIP J 30 "0 x 90' 18 GA GALV. \ i � \ C ONNECTIONS Q M h. 24-' .... H 1 ■ _ END OF 24 5'- 9" / 8'- 0" - -- „9 -,91 A.H.U. #1 "SP I 20 GP, GALV. BEADED SLEAVE COUPLING WITH 4" SLEAVE. TYPICAL DUCTS SMALLER THAN 37 "0 24"0 20 GA GAIT LONGITUDINAL SEAM 20" X 12" TITUS DRUM LOUVRE Q 600 CFM (TYP 6) 18500 �i M L 2.5 M551 30 "0 18 GA GALV. BULLHEAD TEE WITH 5 TURNING VANES AND SLIP CONNECTIONS 4'- 6" I / 9-,91 A A _ ^ J �24 "4 20 GA GALV. LONGITUDINAL SEAM DUCT 20 GA GALV. 20 GA GALV. BEADED SEAM SLEAVE COUPLING WITH 4" SLEAVE. TYPICAL DUCTS SMALLER THAN 37 "0 60 "4 18 GA GALV. LONGITUDINAL SEAM DUCT IN MAXIMAM 5' -0" 6'- 0" 36" 3'- 5" _ --.11 11 30 "4 20 GA GALV. 18 36 "0 20 GA GALV. LONGITUDINAL SEAM LONGITUDINAL SEAM DUCT DUCT 72" LENGTH. 1 1/4" CONDENSATE RETURN (NEW) © 30''0 30 "4 1 1/4" X 1 1/4" X 1/8" DUCT COMPANION FLANGE JOINT FOR DUCTS LARGER THAN 36 "0_ M551 42 "4 x 45' 18 GA GALV. 3 GORE ELL WITH 52" CENTER LINE RADIUS AND COMPANION FLANGE CONNECTIONS (typ 2) SECTION 18 GA GALV. 40/20 TO 30 "4 Y TRANSITION WITH SLIP CONNECTIONS ON THE ROUND END AND DUCT FLANGE ON THE RECTANGLE END. EXISTING I 30" x 12" GRILLE 1000 CFM (TYP 2) r ROOF EL. 40' -0" l J \' D "o L E B-22A W l 1 . t END G T� AEXISTIfti; ON / 10 0" �. 0' J _ BOTTOM OF EXISTING ri __� _ _32=X ' CRI-LL -- 1"-.-„,\-\--- I \ /— __ ! � _i I _ — 22/48 Q e 0O �o Q O o I % 0 22" X 48" DUCT 10' 0" 10'- 0 \ 10 0" "4 LONGITUDINAL 18 20 GA SEAM GALV. DUCT 1000 CFM 1 it 1, 0 ----7 I #I 20 42 ' f o OO o O { 7 "4 x 90' 11VGA GALV, MITERED ELL N -S BEAM \,...‘" oo -0.... OOee r MI 4 WITH S TURNING VANES AND SLIP 30 "0 x 90' 18 GA GALV. C ONNECTIONS Q ■ 5 GORE ELL WITH 30' CENTER LINE RADIUS SLIP CONNECTIONS 10'- 0" I 9'- 0" 8'- 0" - -- „9 -,91 Io n ga galv. longitudinal seam - 20 GP, GALV. BEADED SLEAVE COUPLING WITH 4" SLEAVE. TYPICAL DUCTS SMALLER THAN 37 "0 24"0 20 GA GAIT LONGITUDINAL SEAM 20" X 12" TITUS DRUM LOUVRE Q 600 CFM (TYP 6) © M551 M551 30 "0 18 GA GALV. BULLHEAD TEE WITH 5 TURNING VANES AND SLIP CONNECTIONS A A _ ^ /f \, r"-- C 1Tt OR 1 a { D41� CITY OF TU 'AN 1 0 J1:2 REVISION 702415 -02 BY KGP APPROVED RWS DATE 20- NOV -D1 SYM 2.5 REVISION BY APPROVED DATE SCALE: 1 /4' =1 " -0 SECTION SCALE: 1/4"=1' -0" gLAMOAEliet"' 1M11 1M506 A 1M11 1M506 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEP, DATE DRAWN K. PENROD CHECKED ERCWEER NECKED DATE 8.21.01 1.5 1.5 SUBTITLE TITLE HVAC SECTIONS & DETAILS sai'll CURRENT REVISION SHEET 702415 -02 1 SYMBOL M550 _ PERMIT CENTER DATE 20- NOV -01 4 i ROOF, EL. 40'- ( ) lJ l ( ) ( ) lJ Li r l J S N s 12 "0 20 GA GALV. LONGITUDINAL SEAM DUCT 18 "0 20 GA GALV. LONGITUDINAL SEAM DUCT ■1 20" X 12" TiTUS 18 GA GALV. •DRUM LOUVRE 18" X 12" X 12" LONG 600 CFM (TYP 2) - / / Q M551 _' �, I OONCENTRIC- REDUCER `SLIP CONNECTION . a 551 V 51 I N � I i ACING WITH B -22 —SH UM 2/1 PITCH. PROV. '.T A SAME. 30' INTERVAL TRANSVERSE BRACING HOLE ADJ. HINGE TO HANGERS & STRU ING WITH B -22 —SH IMUM 2/1 PITCH. PROV. AT A MAX. 30' INTERVAL HOLE ADJ. HINGE TO HANGERS & STRUCTURE REVISION SCALE: NONE SCALE: NONE 702415 -02 BY KGP 11 GAUGE DUCT BAND DETAIL: SEISMIC DUCT BRACING APPRO RWS COL. LINE BEAM WITH /� EMBEDDED UNISTRUT CHANNEL 1/2 "0 ALL THREAD SUPPLY DUCT DETAIL: ROUND DUCT HANGER UNDERNEATH BEAMS COL- LINE BEAM WITH EMBEDDED UNISTRUT CHANNEL DATE 19— NOV -01 ATTACH VERTICAL STRUT TO HORIZONTAL MEMBER WITH B —LINE 4 HOLE ANGLE 3 1M11 M551 REVISION SECTION SCALE: 1/4 " =1' -0" 1M11 M551 C 1M11 M551 USE 1/2 "0 BLOTS AND NUTS TO BOLT B -22A DBL. STRUT WITH U— CLAMPS TO CONCRETE INSERTS IN BEAMS EXISTING CONCRETE BEAM APPROVED SCALE: NONE ATTACH VERTICAL STRUT TO HORIZONTAL MEMBER WITH B —LINE 4 HOLE ANGLE DATE 16 GA DUCT STRAP TO FIX DUCT TO TRAPEZE HANGER. SCALE: NONE B —LINE B -22A, DBL STRUT EXISTING CONCRETE BEAMS DETAIL: ROUND DUCT HANGER BETWEEN BEAMS 1M11 M551 p_.mo�seoc. N-1/2" ALL THREAD SUPPLY DUCT �1 1/2" WIDE X 16 GAUGE DUCT BAND 1/2 THREAD ROD WITH TRAPEZE HANGER AT MAXIMUM 8' INTERVAL. USE B -22 SG TRUT AS VERT BRACE. B —LINE #22 —A DBL STRUT DETAIL: SEISMIC DUCT BRACING USE 1/2 "0 BLOTS AND NUTS TO BOLT B -22A DBL. STRUT WITH U- CLAMPS TO CONCRETE INSERTS IN BEAMS TRANSVERSE BRACING WITH B -22A DBL STRUT AT A MAXIMUM 2/1 PITCH. PROV. SEISMIC BRACING AT A MAX. 30' INTERVAL USE B, LINE FOUR HOLE ADJ. HINGE TO BOLT BRACING TO HANGERS & STRUCTURE 4 1M11IM551 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT DATE CHECKED N DRAWN CHECKED TRAP: 2" 0 AMSTRONG MODEL 15 —B8 -2 ATE TITLE SUBTITLE 0 UPGRADE COMPRESSED AIR SYSTEM 1/4" STEAM COIL HEATING SCALE: N.T.S. SECTIONS AND DETAILS CONTROL VALVE "ROBERTSHAW" NO. 2510- 058 -3" P.R.V. 3 "- 150/15 PSI SARCO 25P FLG 1M61 M551 3 "0 STEAM SUPPLY CURRENT REVISION 702415 -02 SYMBOL SHEET M551 CITY OF T KW LR A °PRV`iED JAN 18 2 " AS i,u,Lo stir_ RE000IED CIT OF TOKWILA. JA!•! 1 9 L;iiI PEHMFTGENTER DATE 19— NOV -01