Loading...
HomeMy WebLinkAboutPermit M02-008 - CONTINENTAL MILLSM02 -008 Continental Mills 18000 Andover Pk W. City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049018 Address: 18000 ANDOVER PK W TUKW Suite No: Tenant: Name: CONTINENTAL MILLS Address: 18000 ANDOVER PK W, TUKWILA, WA Owner: Name: LA PIANTA LTD PARTNERSHIP Address: PO BOX 88050, TUKWILA WA Phone: (206) 575 -3200 W Contact Person: ? Name: BRETT PETERSON Phone: 253 437 -7189 Address: 18000 ANDOVER PK W, TUKWILA, WA w W m p Contractor: v c Name: G L Y CONSTRUCTION INC Phone: a F .. ' Address: PO BOX 6728, BELLEVUE, WA W W Contractor License No: GLYCOI *01809 Expiration Date: 09/30/2002 2 .-O 11.1 Z U H Value of Construction: $96,000.00 $130.19 Z Type of Fire Protection: SPRINKLERS, AFA 1997 DESCRIPTION OF WORK: PROVIDE AND INSTALL EXHAUST HOODS AND UTILITY DISTRIBUTION SYSTEM Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or thg performance of work. I am authorized to sign and obtain this mechanical permit. Signature:9W Print Name: r eAcc KAA- C_ MECHANICAL PERMIT doc: Mech This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -008 Permit Number: MO2 -008 tu re Issue Date: 02/07/2002 V Permit Expires On: 08/06/2002 a 0 co o tu u. W O' J (A d Fees Collected: Uniform Mechnical Code Edition: Date: 2 7 DL i Date: 711-'02- Printed: 02 -07 -2002 ACTIVITY •: NUMBER: MO2 -008 DATE: 01 -16 -02 PROJECT NAME: Continental Mills R & D Remodel SITE ADDRESS: 18000 Andover Park West XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: N e4A wilding Division re p IOC. t- -o' Public Works DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP n TUES /THURS ROUTI G: Please Route Structural Review Required ri No further Review Required REVIEWER'S INITIALS: Incomplete APPROVALS OR CORRECTIONS: (ten days) Approved C Approved with Conditions 1 IZ 1 ---#9 Fire Prevention NOG I,V:, —1 2 Structural Planning Division Permit Coordinator DUE DATE: 01-17-02 Not Applicable n DATE: DUE DATE 02 -14 -02 Not Approved (attach comments) Ti REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: Approved Approved with Conditions Ti REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 PERMIT COORD COPY DUE DATE Not Approved (attach comments) DATE: Complete TUES /THURS ROUTING: Please Route \PRROUTE.DOC 5/99 REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -008 DATE: 01 -16 -02 PROJECT NAME: Continental Mills R & D Remodel SITE ADDRESS: 18000 Andover Park West XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division X Fire Prevention Public Works Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) StructyralReview Required APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: V-Ckt CORRECTION DETERMINATION: Approved n Approved with Conditions n u DUE DATE: 01-17-02 Incomplete n Not Applicable Planning Division Permit Coordinator No further Review Requir d DATE: DUE DATE 02 -14 -02 Not Approved (att ch co ments) ( I DATE: DUE DATE Not Approved (attach comments) REVIEWER'S INITIALS: DATE: I PERMIT NO.: MD 2. " 005 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 2 Pre- construction ❑ 50 WSEC Residential ❑ 60 WA Ventilation /Indoor AQC ❑ 610 Chimney Installation/All Types ❑ 700 Framing ❑ 1080 Woodstove ❑ 1090 Smoke Detector Shut Off 1100 Rough -in Mechanical ❑ 1101 Mechanical Equipment/Controls ❑ 1102 Mechanical Pip/Duct Insul ❑ 1105 Underground Mech Rough -in ❑ 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final ❑ 4015 Special -Smoke Control System CONDITIONS 10001 No changes to plans unless approved by Bldg Div 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I 10005 All permits, insp records & approved plans available 10014 Readily accessible access to roof mounted equipment 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: G•w 111 64)k i ( AAT Y (5 FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) r Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP/1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'l Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Permit Tech: SKS Date: Date: ( ACTIVITY NUMBER: MO2 -008 DATE: 01 -16 -02 PROJECT'NAME: Continental Mills R & D Remodel SITE ADDRESS: 18000 Andover Park West XX Original. Plan Submittal Response to Incomplete Letter # _Response to Correction Letter #. Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: \PRROUTE,DOC 5/99 PLAN REVIEW /ROUTING SLIP n Fire Prevention Structural ri Structural Review Required Incomplete ri Not Applicable CORRECTION DETERMINATION: Approved Approved with Conditions n n Planning Division Permit Coordinator No further Review Required DUE DATE 02 -14 -02 Not Approved (attach comments) REVIEWER'S INITIALS: PC-- # .- DATE: / 2 3- 0? P DUE DATE: 01-17-02 DATE: DUE DATE Not Approved (attach comments) n DATE: Projett. NamefTenant (�N'F► rip./ h� �� /s >�G D � ' � Itla> „City State /Zip: ties Ai et�„ I Aa t,�/ - Value of Mechanical Equi ment:� ? (ter Tax Parcel Number: Site Address : 6006 auleriva e k Property O er: , A b el 44 A41 AA It /• r 84148 . Phone: (� Street Address: WI 2-6 41nver -- a.rk- v.k.sl- City State/Zip: - 11.411-4,4 I A- W►4 iel tt Fax ft: ( ) Contractor: 6 v � V �1, inalim . Phone: ( — L/.37.-7(4.39 Fax it: ( ) 25 3 — 1 -(3? — ? 1 Ot Street Address: 100 114j Air, . SE. City State/Zip: Ze.ltcvt,.t, WA c j 4 Contact Person: Ertl{ f e lecseA/ Phone: ( ) 253 411-1-1 el Street Address: Sa.w.t. as s,rk add r t�5 City State/Zip: Fax ft: ( ) 25 44} -1-1 P'Q . BUILDING OWNS w R'AUTHO; i ENT: jyvt i ■ 4— qtr , b.. • 1, • ' Date: t , / • _ inalim 13 /'bw.✓ - . _ - 807 Address: ' D r S . t'1 Al e 34 City ate i s f i e D 3 ___. JAN 15 ' 02 10: 3 0AM TIJKWILA DCD /PW sai CITY OF . tJKW1LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 P. 2 /3 Project Number. Permit Number,. ({ STAFF I,JSE ONLY en 0ke0a ; I, Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. • MECHANICAL PERMIT REVIEW ANDAPPROVAL REQUESTED: (TO BE FILLED OUT'BYAPPLIGANT) ' t ;. Descri Lion of work to be done (ple se be specific): t r»vtaC( ane 2rt Sir /I 6 Aausue- / I $ 4 rtel Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11/2/99 Expiration of Plan Review • Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform mechanical Code (current edition). No application shall be extended more than once. Dace application accepted: / / Zr nc92 Dace application expires: Application taken by: (initials) ZWIS doc: Conditions City of Tukwila Parcel No.: 3523049018 Address: 18000 ANDOVER PK W TUKW Suite No: Tenant: CONTINENTAL MILLS PERMIT CONDITIONS Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Number: Status: Applied Date: Issue Date: 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. that agency, including all gas piping (296 - 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries inspected by that agency MO2 -008 ISSUED 01/16/2002 02/07/2002 Division. Plumbing will be inspected by and all electrical work will be (248- 6630). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication showing the fire performance rating thereof. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 10: Manufacturers installation instructions required on site for the building inspectors review. 11: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 12: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any con- struction. These documents are to be maintained and avail- able until final inspection approval is granted. 13: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 14: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 15: Manufacturers installation instructions required on site for the building inspectors review. 16: ** *FIRE DEPARTMENT CONDITIONS * ** 17: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 18: Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking application shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is automatically shut off to MO2 -008 Printed: 02 -07 -2002 City of'1'ukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 all equipment under the hood, when the system is actuated. (UFC 1006) 19: A wet chemical portable fire extinguisher having a minimum rating of 2A:1 B:C:K shall be installed within 30 feet of commercial food heat - processing equipment, as measured along an obstructed path of travel. (UFC 1006.2.7). 20: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard 10 -1) 21: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 22: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 23: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1900. 24: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1- 5.5.4) 25: Local U.L. central station supervision is required. (City Ordinance #1900) 26: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 27: Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1900) 28: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1900) 29: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 30: In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) 31: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. (City Ordinance #1900). 32: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) 33: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 34: Doors into electrical control panel rooms shall be makred with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. (UFC 8509.3) 35: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions &2( Date: i? /7 ffz_ MO2 -008 Printed: 02 -07 -2002 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 RECEIPT Parcel No.: 3523049018 Permit Number: MO2-008 Address: 18000 ANDOVER PK W TUKW Status: APPROVED Suite No: Applied Date: 01/16/2002 Applicant: CONTINENTAL MILLS Issue Date: Receipt No.: R020000177 Payment Amount: 130.19 Initials: SKS Payment Date: 02/07/2002 09:30 AM User ID: 1165 Balance: $0.00 Payee: SMITH & GREENE TRANSACTION LIST: doc: Receipt Amount Type Method Description Payment Check 48612 130.19 ACCOUNT ITEM LIST: Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES Description Account Code 000/322.100 104.15 000/345.830 26.04 Total: 130.19 17 Riinted: 02-07-2002 Projet ; I f twri p m e j 1 /(CJ_ Type of Inspection Address: /4 called .. Special instructions: Date wa mm. Requester: ',: Phone: :. . INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 OMMENTS: $47.00 REINSPECTION 'E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: , Date: INSPECTION RECORD Retain a copy with permit Approved per applicable codes. Corrections;required prior to approval. . PERMIT NO. . (206)431 -3670 Project. ' 1 Type of Ins ection: Address: dress: , � 1 ate called: ` . Special instru ions: ,�•i -`( ' / - �i Date want e : ,-}� a.m. v1 Requester: / hone:= r nspector: •.,y V ' •.� . l" �'/ �`,f X/. w. i,?• 1if�f' 7,epw,ti$:iiU:'iti.;s��l.w;�t��: b�n'4.Ck' :�leiji''i.:� }'.re r1 r INSPECTION RECORD Retain a topy permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVSION';, 6300 Southcenter Blvd, #100, Tukwila, WA 98188 $pproved'}ier icable odes. OMMENTSr PERMIT NO. (206)431 -3670 orrections;rrequired. 1irior.to approval: $47.00 REINSPECTI • FEE.REQUIREb: Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite °Call to schedule reinspection. Proje : // Type of Ins : ction: Address 404 P ate cal ed: Special instructions: Date wan 5-0 a. p.m. Requester: Phone: ,.e, ti, �^ n^ IM ..:nNb,��r��'Ys`SYIJS��v,,gC•.. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: / 7 tom 5 e y� Q,4 G i.464-e-.103 4- f - taw 4 ‘..5 / • 6 c 1%00,A, 0[4 5.,.,,.� A/ -- $q4' ,..� ,.-4fv k� col." 4 q4., c e'._ 7 . c5U / / 1 I r y `t / / i-za' r' c, t 1"- ..- 4 j '40.17 r." (/1 4 5.. rr ./.4--G i �-�.� 5 . 114',/ a .€4e-7,-,/..,s p,,./ spar cp / ,-.,...6-06.4e.._ Inspector: $47.00 REINSPECTION - REQUIRED. Prior to inspection, fee must be paid at`6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: INSPECTION RECORD Retain a copy with permit ON.* 1 7.Avolie Date: PERMIT NO. (206)431 -3670 Corrections required prior to approval. City of Tukwila Fire Department Thomas P. Keefe, Fbe Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name Csav e.. t' a L � + LL Address 1 0 D O � � �U r' r `C c �1C �.J Qs 1, (6 Retain current inspection schedule X. Needs shift inspection rrl - -- Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre - Fire -r-- Permits: C: 53 'Authorized Signature FINALAPP.FRM Cif S 21 vZ F o3 8 Permit No. Dal — Z51?, 1)1 01 - Z..+ C!)7uz — o r>>ot - 03-1 Date T.F.D. Form F.P. 85 John W. Rants, Mayor Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 • Fax (206) 5754439 Sent By:•Hultz /BHU Inc.; Hultz1BHU.Inc Consulting Engineers 253 383 3283; Apr - 12 10:47AM; Page 1/2 � � L FYI 2 -Q 1407 North 31.0 Street, Sluts 2000 Tacoma WA 98407 0 (253)383 -3257 0 Fas(253)383 -3283 0 general@hultzbhu.cum FAX MEMO To: 1,J15,6 -i. -(,. Date: 4- / 2. -o 7-- Attn: h100/�.1 Sri /4 - A.. From: J1 !v /J let)) Ta,) Subject: C.-4W r'l J 1 r - ) ► +- i- C File No: d / - O 7D Copied: 3 /very &Mt...co,...) -GLY Fax No: I (Z01.) 2 - 9 1 4 1 - ! ��1� -Z1 +5' 3 - S'(o e 0 :Dxtvt= L iz ��..1 ^ c, i of 7 ri., ,c, Total Number o f Page 39,s- n ding cover shee : i C Zo o ) µ 3 I - 4.3'" Hard Copy Will Be Sent: Yes/No e.4$7/3 O� S /G•r % tiid S - I�•/ /"�7� ' 9i )7 , 77Ef , z)2. 732.r97,J.iJG /Leo f o f f / G / f ,C/ 2 - f E.,/ Ai-to r ( � 3 ) 3 63- 3 a S 7 O 00 T oo DA .�} Ey:1ST' Es4 FAAJs /Sr RA RR 2a- too CFA/ • �xrsr. AN v SA > J 2 ;81j> CFA S ` � � 1I 19 6 GEM No r E S CD ( 2 Z x2.2. CLG Exit, LL ES !s14-2_ GFM EA. EF-I OF F- 3 — F• '-- TOTAL Bey Fe°i Ft.2 = 5 244 CFM e L.DG Z aar -AGE SAD cFM 300 C Fri 450 N GFM 800 1— GFM 2Nb. FUL EF- ! — z 2 bJ1> Ft^2 PLE►.1LAM 4, T OTAL. Fix Non SA 114 A!R in1 1,000 1,925 • GFN1 cFM • c0 TRA-• Jh -)6 RM 1 2,925 • GPM rorm -i... RA F Z6/I /s: r c a 14-o cFfr7 NEW EXH SAWS EF -4- EF- 3 I, 560 R 29 GIM c FM 1, 109 4-FM �S r FL-C .PL.0 ,JwM SA 9,00o cFM g!_ da LERIe/4GE SOO GFM 'OA ,9,b Goo G A7414 -1 NOTICE: IF THE DOCUMENT IN This FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. t w w oo w 21 me. IN Ro = O Z � x CO CO (i) w N o w rn y r N ‘10 N 0 -4 - m CCIt CD N N /1,64.4/ 64/3 ) 7/"Y Balance Due: $ /80./ r Need Current Contractor Registration Card: L Yes 'No Need to Enter Contractor Information in Sierra: D Yes vff-No 7-30-4,Z EQUPMENT UST ITEM NUMBER ',yawn° DESCRIPTGON I 1 PRESSURE FRYER 2 1 BREAD SLICER 3 1 SHEETER 4 1 WORK STATION 5 5 INGREDIENT BINS 8 1 SGALE 7 1 SGALE 8 1 WALL SHELF 9 1 MIXER 10 1 MIXER 11 1 FRY WARMER 12 1 SCALE 13 1 MIXER 14 1 WORK STATION 15 1 WORK STATION 16 15 BREAD MACHINES P 17 5 BUS CART 18 1 VENTILATOR 19 1 UTILITY DISTRIBUTION SYSTEM 20 1 STANDARD OVEN 21 1 DOUBLE CONVECTION OVEN 22 1 STANDARD DOUBLE OVEN 23 1 CONVECTION OVEN 24 1 FRYER 25 1 FRYER W/ STAND 26 1 KETTLE W /STAND 27 1 REEL OVEN 28 1 REEL OVEN 29 1 GRIDDLE W /STAND 30 1 GRIDDLE W /STAND 31 1 ROTISSERIE W /STAND 32 1 HOT TOP RANGE 33 1 CONSUMER RANGE 34 1 C ONSUMER OVEN 35 1 CONSUMER OVEN 36 1 CONSUMER CONVECTION OVEN 37 1 COMMERCIAL MICROWAVE 38 1 CONSUMER MICROWAVE 39 1 MOBILE STAND 40 1 VENTILATOR 41 1 UTILITY DISTRIBUTION SYSTEM 42 1 PROOFER 43 1 SOILED DISH TABLE /POT SINK 44 1 CONDENSATE HOOD 45 1 WARE WASHER 46 1 GLEAN DISH TABLE 47 - SPARE NUMBER 48 1 WALK -IN COOLER /FREEZER 49 1LOT COOLER SHELVING 50 1LOT FREEZER SHELVING 51 1 REFRIGERATION SYSTEM 52 - SPARE NUMBER 53 3 GUTTING TABLE 54 1 FRY GUTTER 55 1 DISPOSER 58 1 UTENSIL RACK 57 1 WALL 'SHELF 58 1 UNDERGOUNTER WARE WASHER 59 1 UNDERGOUNTER WARE WASHER 80 ; 1 DISPOSER FRY STATION 4•x6• PIPE CHASE -, EQUIPMENT SHOWN N THIS LOCATION FOR DEMO /TRAINING USE MOVED FROM MAIN COOKING AREA 69, Kitt() Qt 6 T 56 L_JL_J i I SAMPLE FIXES T — FI %NG FIR BAKING 2 ELHNI[A SERIVVICE *. ITEM #40 REMOTE ®® S SUPPRESSION SYSTEM DATA A i 4 THRAI:1E_ N 1ZeEE4 re, CC-0 rtg• 1e-tee-ere-0 0-6 KG -1 - EQUIFMENT KG -2 - SCHEDULES KG -3 - UTILITIES KC -4 - ELEVATIONS KG -5 - ELEVATIONS TRAIN11 \1G PQGH SUBMITTAL REVIEW ❑ /PROM ils SUMMED »; *pR°vm NOTD o mu.) commatan o mow Rem t n win 'sag : SUPPUEF.. 311 *�1RSnM ikA01R ryUGy IIKfNt*L'aFN�S If CCW'IR�Gi KAN4 AIYJ L^E37LAI� CURrY'.f.AT Or VRp'EF.. cA nm!S Sf F3 ROEA A404 AR R NE . 1tE . suPrll3xs a71995S L:iE. D A T E : I 2 / 1 / 6 1 1 (206) 523 -9620 BY: 51.1 � - __l GEORGE E. BUNDY k ASSOCIATES Y_i�®�� .1026 N.E RAVENNA BL4D.' SEATTLE. WASHINGTON 98105 I 1 1_ I. ' RECEIVED NOV 27 2001 GLY CU NO CHANGES SHALL BE MADE TO TriE SCOPE OF WORK WITHOUT PRIOR ; a-ROVAL OF TUKWILA BUILDING DIVISION. NOTE: RDAS*. WRL REQUWE A NEW PUN SUBMITTAL MB MAY niiA°7E AAOTONAL PLAN REVIEW FEES. FILE COPY I understand that the Plan Check approvals are subject to elrors and omissions and approval of plans does hot authorize the violation of any adopted cede or ordinance. Receipt of con- tractors cply of approved plans acknowledged. By f° v0 Date 2I -162 Permit No. MOa ^ oo6-11400 -c STORAGE REvisl6Na tl 1 are NOTED ' (h) NOT APPROVED -CORRECTS RESUBMIT This revieN does not rdieve the sum,. from °Inva ens vbdMt earusorccnanlaacysocetals quantities aart cewnh he contract GL ONS 'U PO JAN 3 0 2002 o As NO g` L 7G t51,94 H _ SEPARATE PEW 1/ REQU RED FOR: MECHANICAL [J�LEDTRICAL LI.MBIP4G re& PIPING CITY OF TUKWILA BUILDING DIVISION 0 U *At 1Wz fV ttl m Z r — O� z V IL 3sJ :3F 34 O 33 [ ! __ ij DM 23 — 31 24 f I XL_J ' I e I:11 lull FRY STATION 4•x6• PIPE CHASE -, EQUIPMENT SHOWN N THIS LOCATION FOR DEMO /TRAINING USE MOVED FROM MAIN COOKING AREA 69, Kitt() Qt 6 T 56 L_JL_J i I SAMPLE FIXES T — FI %NG FIR BAKING 2 ELHNI[A SERIVVICE *. ITEM #40 REMOTE ®® S SUPPRESSION SYSTEM DATA A i 4 THRAI:1E_ N 1ZeEE4 re, CC-0 rtg• 1e-tee-ere-0 0-6 KG -1 - EQUIFMENT KG -2 - SCHEDULES KG -3 - UTILITIES KC -4 - ELEVATIONS KG -5 - ELEVATIONS TRAIN11 \1G PQGH SUBMITTAL REVIEW ❑ /PROM ils SUMMED »; *pR°vm NOTD o mu.) commatan o mow Rem t n win 'sag : SUPPUEF.. 311 *�1RSnM ikA01R ryUGy IIKfNt*L'aFN�S If CCW'IR�Gi KAN4 AIYJ L^E37LAI� CURrY'.f.AT Or VRp'EF.. cA nm!S Sf F3 ROEA A404 AR R NE . 1tE . suPrll3xs a71995S L:iE. D A T E : I 2 / 1 / 6 1 1 (206) 523 -9620 BY: 51.1 � - __l GEORGE E. BUNDY k ASSOCIATES Y_i�®�� .1026 N.E RAVENNA BL4D.' SEATTLE. WASHINGTON 98105 I 1 1_ I. ' RECEIVED NOV 27 2001 GLY CU NO CHANGES SHALL BE MADE TO TriE SCOPE OF WORK WITHOUT PRIOR ; a-ROVAL OF TUKWILA BUILDING DIVISION. NOTE: RDAS*. WRL REQUWE A NEW PUN SUBMITTAL MB MAY niiA°7E AAOTONAL PLAN REVIEW FEES. FILE COPY I understand that the Plan Check approvals are subject to elrors and omissions and approval of plans does hot authorize the violation of any adopted cede or ordinance. Receipt of con- tractors cply of approved plans acknowledged. By f° v0 Date 2I -162 Permit No. MOa ^ oo6-11400 -c STORAGE REvisl6Na tl 1 are NOTED ' (h) NOT APPROVED -CORRECTS RESUBMIT This revieN does not rdieve the sum,. from °Inva ens vbdMt earusorccnanlaacysocetals quantities aart cewnh he contract GL ONS 'U PO JAN 3 0 2002 o As NO g` L 7G t51,94 H _ SEPARATE PEW 1/ REQU RED FOR: MECHANICAL [J�LEDTRICAL LI.MBIP4G re& PIPING CITY OF TUKWILA BUILDING DIVISION 0 U *At 1Wz fV ttl m Z r — O� z V IL FOOD FACILITIES EQUIPMENT SCHEDULE W g 0 W DESCRIPT OIL z O ~ -I O o MANUFACTURER Q�IC�)DLI� I� ®. WATER WASTE ELECTRICAL GAS STEAM D= W !1 � t1 t Z KEY: 0 (A W ~ z KEY: 0.F.0.1. - OWNER FURN., GINNER INSTALLED O F C . GVVNERFURN.,CONTR.WSTAU.ED CFC .I.- COlRRFURN.. CONTR.INSTALLED N.I.C. N OT IN INSTALLING TRADES C - CONTRACTOR - KITCHEN CONTRACTOR fA- MECHANK AL CONTRACTOR , E- ElECTRICJILCONTWUSTOR o- G+nnaER o v ...... O o - ci V O _ o C.) o z W. z c y I- _. ° In D rn D' d 0 m )- n ( REF`,', \RK� 1 1 PRESSURE FRYER CHESTER FRIED EXISTING MGF -20 240 1 22.0 1 *no 0 2 1 BREAD SLICER BERKLE EXISTING MB 120 120 1 1 6.2 10.8 2 3 1 121111 ©R 0 0 3 1 SHEETER ACME EXISTING MRS II 4 1 WORK STATION FABRICATE 4 .® K 5 5 INGREDIENT BINS RUBBERMAID 3602 5 113 K 6 1 5GALE OHAUS EXISTING 7 1 SCALE OHAUS EXISTING 120 1 X �$ 0 8 1 WALL SHELF FABRICATE 8 M© K 9 1 MIXER HOBART EXISTING A200 1/2 120 1 9 ©■ KE 10 1 MIXER HOBART EXISTING A200 1/2 750W 120 120 1 1 10 11 ©■ X KE 0 11 1 FRY WARMER KEATING EXISTING 12 13 1 1 5GALE MIXER OHAUS EXISTING KITCHEN AID EXISTING K5MG505 �� 120 120 1 1 3.0 12 13 X X ®® O 0 14 15 1 1 WORK STATION WORK STATION FABRICATE FABRICATE 1/ F.S. 14 15 M© •© KM K 18 15 BREAD MACHINES REGAL EXISTING IIMMINIEW FEE ■ 480W. 120 1 18 17 X MI o© O K 17 5 BUS CART w, RE FABfICATE 18 1 VENTILATOR HALTON KVC 120 20/208 1 3 (LIGHTS 1" 500K CLOG ED) 18 19 113 M® KEM KEN 19 1 UTILITY DISTRIBUTION SYSTEM HALTON KD5 1/2" 1/2" 20 1 STANDARD OVEN MONTAGUE EXISTING 1365 3/4" 40K 20 ©N KM PROVIDE AND INSTALL GASTERS ON UNIT 21 1 DOUBLE CONVECTION OVEN MONTAGUE EXISTING 2 -115A (23120 1 7 . 4 '233/ 4115Kea 21 ©® KEM ' PROVIDE AND INSTALL CASTERS ON UNIT 22 1 STANDARD DOUBLE OVEN MONTAGUE EXISTING 236 3/4' 80K 22 ©® KM PROVIDE AND INSTALL CASTERS ON UNIT 23 1 CONVECTION OVEN LANG 2GGGO -AP C2)120 1 7.1ea .23 1/2'55Kea 23 ®® KEM PROVIDE AND INSTALL CASTERS ON UNIT 24 1 FRYER TRY MASTER EXISTING H17FD 17.0 208 3 24 ®® KE PROVIDE AND INSTALL CASTERS ON UNIT 25 1 FRYER W /STAND WELLS EXISTING FG7 6.9 208: VERIFY 25. ®$ KE PROVIDE WITH NEW 5TAND 26 1 KETTLE W /STAND GROEN EXISTING TDB /7 -20 1/2• 1/2" F.5. 0.3 208 VERIFY 26 ©m KEM 27 1 REEL OVEN REED EXISTING R9762 120 1 10.0 3/4" 100K 27 ®■ KEN C23'0" DIA. EXH. DUCT CONN'S. VERIFY REQUIREMENTS WITH MFR. 28 1 REEL OVEN REED EXISTING 89762 120 1 10.0 3/4" 1OOK 28 ©i KEM C23 6" DIA. EXH. DUCT CONN`S. VERIFY REQUIREMENTS WITH MFR_ 29 1 GRIDDLE W /STAND STAR EXISTING 515TGA 750W. 208 1 29 In KE PROVIDE WITH NEW STAND 30 1 GRIDDLE W /STAND HOBART EXISTING 0055 12.0 208 3 30 ©I KE PROVIDE WITH NEW STAND 31 1 ROTISSERIE W /STAND HENNY PENNY EXISTING SCR 0 208 3 22.8 31 ®® KE PROVIDE WITH NEW STAND 32 1 HOT TOP RANGE SOUTHBEND 164 -1 1 ' 40K ®: KM PROVIDE WITH REAR GAS CONNECTION AND s cAT 33 1 CONSUMER RANGE EXISTING 220 1 KE PROVIDE AND INSTALL CASTERS ON UNIT 34 1 CONSUMER OVEN GENERAL ELEGTRIG EXISTING JKP13GV 2.6 220 T 34 ®I KE 35 1 CONSUMER OVEN GENERAL ELECTRIC EXISTING JKP13GV 26 220 1 35 X KE 36 1 CONSUMER CONVECTION OVEN KITCHEN AID EXI SUPER SELEGTA 30 2.6 220 1 _ X KE 37 1 COMMERCIAL MICROWAVE MENUMASTER GENERAL ELECTRIC EXISTING F5 10 EVP JES 1030TWOO2 1.05 125 120 120 1 1 37 38 ©• ©m KE KE 38 1 CONSUMER MICROWAVE 39 1 MOBILE STAND FABRICATE 39 ■© K 40 1 VENTILATOR HALTON KVC 120 1 (LIGHTS.) 40 •© KEM 41 1 UTILITY DISTRIBUTION SYSTEM HALTON KD5 1/2' 1/2" 120/20' 3 1" 500K CLOOFED) 41 I© KEN 42 1 PROOFER DOUGH'S DELIGHT EXISTING 3001 2.0 120 1 42 ©i KE, 43 1 SOILED DISH TABLE /POT SINK FABRICATE 2)3/4:12)3/4 C3) 2" 43 l© KM 44 1 CONDENSATE HOOD FABRIGATE • 13,5' 158 44 ■© KEM 8 -x10 "' EXHAUST DUCT CONN. s 1000GEM. FAN SWITCH BY E.G_ 45 1 WARE WASHER HOBART AM -14TC 3/4" F.5 C23219$ 3 ..:. 3re1 45 ■© KEN 2 ELEC. CONN'S. - 25 (MOTORS + CONTROLS) + 3S IAMPS C70 RISE BOOSTER 46 1 GLEAN DISH TABLE FABRIGATE 48 ■© K 13'5 15.8 47 - SPARE NUMBER 47 ll 48 1 WALK -IN COOLER /FREEZER IMPERIAL MANUFACTURING F.S 120 1 48 MU KEN 49 1LOT COOLER SHELVING INTERMETRO Q - - - -G 49 N© K 50 1LOT FREEZER SHELVING INTERMETRO - - - -NG 50 © K KEM A C .OLEO U I T= E R I FY 1 -.0c--P0 -1 . 0 1 . 4 51 52 1 - REFRIGERATION SYSTEM SPARE NUMBER GOLDZONE MPL -1GZ 205 -230 3 22.8 51 52 :: A • 53 3 CUTTING TABLE FABRICATE 53 X MI O 54 1 FRY GUTTER EXISTING 54 OM K 55 1 DISPOSER SALVAJOR 100 -SA -WJ 1/2" V 1 208 1 55 no KEM TEE GOLD WATER FROM ITEM #14 56 1 UTENSIL RACK FABRIGATE 5657 K 57 1 WALL SHELF FABRICATE IIII 58 1 UNDERGOUNTER WARE WASHER EXISTING 58 KEN LOCATED PER ARCHITECTURAL 59 1 UNDERGOUNTER WARE WASHER EXISTING 59 ©I KEN LOCATED PER ARCHITECTURAL 60 1 DISPOSER SALVAJOR 100 -SA -WJ 1/2" 1/2" 2" 1 208 1 60 I® "KEM PROVIDE WITH PRE- RINSE FAUCET 81 61 ME - UACCE4 is ?(2.0,10e6 L- at r. Mb2o? KC -I - EQUIPMENT KC -2 - SCHEDULES KC -3 - UTILITIES KC -4 - ELEVATIONS KG -5 - ELEVATIONS U I.1 RECEIVED • CITYOFTUKWRA JAN 1 6 T T PERMIT CENTER 120/10 Ci: 208/30 POWER AND CONTROL J WIRING PREYNRED DOOR PANEL. - REMOTE PULL SWITCH GENERAL NOTES SINGLE SPECIAL POWER RECEPTACLE 30A- 208V /1PH UNLESS OTHERWISE INDICATED. FLUSH FLOOR BOX 0 COMPUTER DATA LINK 1. REQUIREMENTS SHALL STUB OR SLEEVE THRU MOOR TO FACILITATE CONNECTING TO EQUIPMENT. MERE WORTS ARE NOM, REQUIREMENTS TO RISE WITHIN WALLS, ON COMMUNE, AND STUB NAj0 EO H OUT AT SAIDIITS. HARD PIPING TO EXTEND THR U EINCHES OUT FROM WALL MAC UNLESS OTHERWISE NOTED. 2. ALL ELECTRICAL OUTLE S AND CONNECTIONS ARE TO BE GROUNDED. S. FAUCETSFURNISIED BY KRONER CONTRACTOR MD INSTALLED TO FO(TURES BY MECHANICAL COMMA... 4. SIN( WASTE FD'INGB AND TABPIECEB FURNTBHED ON SINKS BY KITCHEN OONIRACTOR. T'TRMB AND CONCOCTING SECTIONS TO ROOM. FURNISHED AND INSTALLED BY LOCHIAMCAL CONTRACTOR 5. FLOOR WASTES AND PULSING FIXTURES BY MECILANCAL CONTRACTOR S. FIRE -FUEL SHUT-OFF REOUNED ON Al. EECTRK,ALAND GAS EDLIPLEM UNDER VENTILATOR. PROVIDED AND METALLED BY B.ECTRCALANCOR IIECHANGA, CONTRACTOR PLUMBING: PPM FOR WATER WASTE. STEAM SUPPLY AND RETURN, NCLDMIBTRAPB, MINOS. NORM VALVES. CONNECTIONS BETWEEN PPM AND THE VARIOUS PECES OF EQUIPMENT WILL BE MADE BY MECN'•AB^y CONTRACTOR AT TM TILE EQUIPMENT IS BEING NITALLED BY KITCHEN CONTRACTO GNNCALCONTRACTOR MOLL NBTAU_ ALL FIANCE, VALVES, AND CONTROLSFNCMSHED NNE FOOD seem EOLMPENT LDOBENEUB, AND MALL PROVIDE ALL NIERCONIOC LNG PIPING REQUIRED TO COMPLETE EACH EQUPMENT HOOKUP TO THE POINT OF FMNAL CONNECTION FOR TIE UNLITYSERVICE. ELECTRICAL: THE ELECTRICAL CONTRACTOR WILL ROUW4N CORNET% PILL•N WIRE AND CONNECT CIRCUITS TO EQUIPMENT. THE ELECTRICAL CONTRACTOR WILL TERMINATE HIS WORK ATATERMINAL BOX, POWER PANEL. STARTER. OR 018CONNECT8IAITCH INSTALLED CN THE F000 SERVICEEBWUENT. FIELD MARR00 BY THE ELECIPoCALCONTRA, .'TOR WLL NCNIDEALL NECESSARY LATERALS AND CONNECTIONS TO OPERATE ANY ELEC ROAM EQUIPMENT REQUITING ON SITE ASSEMBLY. SUCH AS MUM BOXES. VEND ATORS AND RACEWAYS. SWITCHES, DECK OVENS, ETC. COOLER/FREEZER REFRIGERATION UNIT RUE CLOCK RUN DRAIN UNE OUTSIDE OF FREEZER TO NEAREST FL DRAIN. -\ OUTLET FOR DRAIN LINE HEATER • (BENEATH BL. COIL) BLOWER COIL ELECTRIC DEFROST HEATED AIR VENT OOR HEATER WALK -IN FREEZER DETAIL (TYP) ELECTRIC DEFROST SYSTEM ELECTRICAL REQUIREMENTS COMPRESSOR BLOWER COIL 208V/30, 2.51-IP 208V/10. 2.2AMP5 THERMOSTAT (T) DRAIN LINE HTR. LIGHTS DOOR H1R. HEATED AIR VENT 120V, 2.0 AMPS 120V 80 W. EA. 120V, 3.0 AMPS 120V. 1.5 AMPS NOTE: ALL FIELD WIRING SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR, INCLUDES HOOK -UP, INTERNAL AND EXTERNAL WIRING, CONDUIT AND FITTINGS AND LABOR TO MAKE COMPONENTS OPERATIONAL. EXTEND ELECTRICAL FROM FACTORY INSTALLED INCANDESCENT FIXTURE TO FIELD INSTALLED FLUORESCENT FIXTURE(S) AT CEIUNG. UGHT SWITCH IS FACTORY INSTALLED. EXTERNAL THERMOMETER MOUNTED BY K.E.C. AND WIRED BY ELECTRICAL CONTRACTOR. ELECTRICAL ® BLOWER COIL O EQUIPMENT CONN. QJ JUNCTION BOX Sal LIGHTS Qs EQUIPMENT SWITCH $ SWITCH D 20A-120V SINGLE RECEPTACLE 41) 20A -120V DUPLEX RECEPTACLE, WALL MOUNT +411* UNLESS OTHERWISE NOTED DUPLEX RECEPT. WALL MOUNT +18' 20A -120V UNLESS OTHERWISE NOTED ( DUPLEX RECEPT. FIXTURE MOUNT • DUPLEX RECEPT. FIXTURE HORIZONTAL • DUPLEX RECEPT. WALL HORIZONTAL • FOURPLEX SINGLE SPECIAL POWER RECEPTACLE, WALL MOUNT 448' 30A 208Vl1PH UNLESS OTHERWISE NOTED 6 SINGLE SPECIAL POWER RECEPT. FIXTURE MOUNT 30A-208V /1PH UNLESS OTHERWISE NOTED C) CONDUIT STUB 20A -125V DUPLEX RECEPT. FLUSH FLOOR BOX. UNLESS OTHERWISE NOTED DISCONNECT SWITCH 208/30- RUN DRAIN UNE OUTSIDE OF LOCATE IN COOLER COOLER TO NEAREST FL DRAIN. AT BL COIL 120/10 PROVARED DOOR PANEL - WALK -IN COOLER DETAIL (TYP) II A 4 NOTE: MECHANICAL • HOT WATER O COLD WATER ® DIRECT WASTE O WASTE CONNECTION A STEAM SUPPLY A STEAM RETURN D I GAS SUPPLY O GAS CONNECTION CI FLOOR DRAIN I1 FUNNEL FLOOR DRAIN ELI FLOOR SINK - - FLUSH MOUNTED SANITARY TYPE O AIR SUPPLY R'1 HYDRAULIC SUPPLY HYDRAULIC RETURN STEAM SHUT-OFF VALVE VENT PIPE BEVERAGE CONDUIT CHILLED WATER SUPPLY CHILLED WATER RETURN COOLER/FREEZER REFRIGERATION UNIT AIR VENT ELECTRICAL REQUIREMENTS COMPRESSOR BLOWER COIL THERMOSTAT (T) DRAIN UNE HTR. LIGHTS DOOR IITR. HEATED AIR VENT 208V/30, 1.OHP 120V, 4.0AMPS NjA N/A 120V, 80 W. EA. NjA N/A ALL FIELD WRING SUPPUED AND INSTALLED BY ELECTRICAL CONTRACTOR, INCLUDES HOOK -UP, INTERNAL AND EXTERNAL WIRING, CONDUIT AND FITTINGS AND LABOR TO MAKE COMPONENTS OPERATIONAL EXTEND ELECTRICAL FROM FACTORY INSTALLED INCANDESCENT FIXTURE TO FIELD INSTALLED FLUORESCENT FIXTURE(S) AT CEILING. LIGHT SWITCH IS FACTORY INSTALLED. EXTERNAL THERMOMETER MOUNTED BY K.E.C. AND WIRED BY ELECTRICAL CONTRACTOR. __ � - _ - - IT'-' I PLUG MOLD BY E.C., SEE SHEET #K2 FOR REQUIRED LOADS, PLUS ADD ADDITIONAL OUTLE U PLUG MOW BY EC., SEE SHEET #K2 FOR REQUIRED LOADS, PLUS ADD ADDITIONAL OUTLETS i 1 O L� I LA J PLUG MOLD BY E.C., SEE SHEET #K2 FOR REQUIRED LOADS, PLUS ADD ADDITIONAL OUTLETS 1/14, 1/2 H /CW, DOWN FROM CLG. THRU CHASE, TEE CW TO PRE -RINSE #55, 2 DIRECT WASTE - .. - F #14 ES. 1i (1) PLUG MOLD ABOVE TOP. (1) PLUG MOLD BELOW TOP 21 10 - . 1D 3' -3 i 188. 208 EC. TO TO S ID #27. (2) 6' EXH. CONN. VERIFY REQUIREMENTS - PE 3/4 GAS CONN. 0 5 100.000 BTU'S. DOWN FROM CEILING TFiLHNICAi. :.•St5•V ILL::.. • • l3 T PIPING 1 Va W GAS CONN. 0 BTU'S, 1/2 OWN FROM 5 KITCHE1" SCALE: #41, X GAS CONN. O 500,000 EN'S. 1/2 • H /CW. DOWN FROM CEILING ADD FLOOR SINK /41, 120/208V/30. 220V. DOWN FROM CEILING 2' -8 4.¢P I',.5 15.10 143. 2)2' TE CONN'S.. PLU H P LOCAL CODES .V/30 AMPS, STUB -UP f(4 5, /30, 5 EAMPS, STUB -UP 120V, PRE -WIRED DOOR PANELS. E R BLOWER COIL, FREEZER NLINE HEATER AND LIGHTS. V FROM CEILING - #20, 120V, 10.0A PS, 3/4 GAS CONN. 0 100.000 BTU'S, DOWN FROM CEILING - #211, (2) 6- EXH. CONN. VERIFY. REQUIREMENTS #37, 120V. 1.05KW +4B' #38, 120V. 1.25KW +48 #60. 20BV/10, 1HP, +18 EC. TO WIRE THRU SWITCH TO SOLINOID AND DISPOSER OS - DIRECT WASTE #60 1/2' H /CW +14 $43. 3/4 H /CW +14' T'-Er DATA 43, 3/4 H /CW +14- 14 2 - -8 #44. FAN SWITCH +50 BY EC. 145. do 4B. FLOOR SINK TIP_ (F.S.) }144. 3/4 HW +16', 120F. MIN. #44„ B's10' EXHAUST DUCT CONNECTION 0 1000CFM �- BLOWER COIL MAINLINE. `- RUN PRIOR TO WALK -IN BOX INSTALLATION. 5 WIRES FROM BLOWER COIL TO COMPRESSOR (LOCATED IN ITEM #51). ELECTRIC DEFROST : T _ If L1 i I L Ti L I 1 Li 1 I +78 ..18 [DOWN FROM CEUNG _ 1/4" = 1' -0" TRAINING ROOM 1 LL L I "U MO2--4008 ROUGH -IN PLAN (D 0 II W ll0II ei fjz __ ` N� VCF TUKNIILA r ■ JAN I PERMIT CENTER KC -1 - EQUIPMENT KC -2 - SCI-IEAULES KC -3 - UTILITIES KC -4 ELEVATIONS KC -B ELEVATIONS 11/5 /01 KC -3 1/•411 =11_ 011 O _ - 11 I 0 \I \I ►fin® (/10, 1HP, I NN 01 THRU S S 01 ANI M vii n .• � II I #48 COC DON 1 �I II ® I 26. VE BY M.C. ■ NE D v T , 500,00C •0- --- CEILING I'M 120/10 Ci: 208/30 POWER AND CONTROL J WIRING PREYNRED DOOR PANEL. - REMOTE PULL SWITCH GENERAL NOTES SINGLE SPECIAL POWER RECEPTACLE 30A- 208V /1PH UNLESS OTHERWISE INDICATED. FLUSH FLOOR BOX 0 COMPUTER DATA LINK 1. REQUIREMENTS SHALL STUB OR SLEEVE THRU MOOR TO FACILITATE CONNECTING TO EQUIPMENT. MERE WORTS ARE NOM, REQUIREMENTS TO RISE WITHIN WALLS, ON COMMUNE, AND STUB NAj0 EO H OUT AT SAIDIITS. HARD PIPING TO EXTEND THR U EINCHES OUT FROM WALL MAC UNLESS OTHERWISE NOTED. 2. ALL ELECTRICAL OUTLE S AND CONNECTIONS ARE TO BE GROUNDED. S. FAUCETSFURNISIED BY KRONER CONTRACTOR MD INSTALLED TO FO(TURES BY MECHANICAL COMMA... 4. SIN( WASTE FD'INGB AND TABPIECEB FURNTBHED ON SINKS BY KITCHEN OONIRACTOR. T'TRMB AND CONCOCTING SECTIONS TO ROOM. FURNISHED AND INSTALLED BY LOCHIAMCAL CONTRACTOR 5. FLOOR WASTES AND PULSING FIXTURES BY MECILANCAL CONTRACTOR S. FIRE -FUEL SHUT-OFF REOUNED ON Al. EECTRK,ALAND GAS EDLIPLEM UNDER VENTILATOR. PROVIDED AND METALLED BY B.ECTRCALANCOR IIECHANGA, CONTRACTOR PLUMBING: PPM FOR WATER WASTE. STEAM SUPPLY AND RETURN, NCLDMIBTRAPB, MINOS. NORM VALVES. CONNECTIONS BETWEEN PPM AND THE VARIOUS PECES OF EQUIPMENT WILL BE MADE BY MECN'•AB^y CONTRACTOR AT TM TILE EQUIPMENT IS BEING NITALLED BY KITCHEN CONTRACTO GNNCALCONTRACTOR MOLL NBTAU_ ALL FIANCE, VALVES, AND CONTROLSFNCMSHED NNE FOOD seem EOLMPENT LDOBENEUB, AND MALL PROVIDE ALL NIERCONIOC LNG PIPING REQUIRED TO COMPLETE EACH EQUPMENT HOOKUP TO THE POINT OF FMNAL CONNECTION FOR TIE UNLITYSERVICE. ELECTRICAL: THE ELECTRICAL CONTRACTOR WILL ROUW4N CORNET% PILL•N WIRE AND CONNECT CIRCUITS TO EQUIPMENT. THE ELECTRICAL CONTRACTOR WILL TERMINATE HIS WORK ATATERMINAL BOX, POWER PANEL. STARTER. OR 018CONNECT8IAITCH INSTALLED CN THE F000 SERVICEEBWUENT. FIELD MARR00 BY THE ELECIPoCALCONTRA, .'TOR WLL NCNIDEALL NECESSARY LATERALS AND CONNECTIONS TO OPERATE ANY ELEC ROAM EQUIPMENT REQUITING ON SITE ASSEMBLY. SUCH AS MUM BOXES. VEND ATORS AND RACEWAYS. SWITCHES, DECK OVENS, ETC. COOLER/FREEZER REFRIGERATION UNIT RUE CLOCK RUN DRAIN UNE OUTSIDE OF FREEZER TO NEAREST FL DRAIN. -\ OUTLET FOR DRAIN LINE HEATER • (BENEATH BL. COIL) BLOWER COIL ELECTRIC DEFROST HEATED AIR VENT OOR HEATER WALK -IN FREEZER DETAIL (TYP) ELECTRIC DEFROST SYSTEM ELECTRICAL REQUIREMENTS COMPRESSOR BLOWER COIL 208V/30, 2.51-IP 208V/10. 2.2AMP5 THERMOSTAT (T) DRAIN LINE HTR. LIGHTS DOOR H1R. HEATED AIR VENT 120V, 2.0 AMPS 120V 80 W. EA. 120V, 3.0 AMPS 120V. 1.5 AMPS NOTE: ALL FIELD WIRING SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR, INCLUDES HOOK -UP, INTERNAL AND EXTERNAL WIRING, CONDUIT AND FITTINGS AND LABOR TO MAKE COMPONENTS OPERATIONAL. EXTEND ELECTRICAL FROM FACTORY INSTALLED INCANDESCENT FIXTURE TO FIELD INSTALLED FLUORESCENT FIXTURE(S) AT CEIUNG. UGHT SWITCH IS FACTORY INSTALLED. EXTERNAL THERMOMETER MOUNTED BY K.E.C. AND WIRED BY ELECTRICAL CONTRACTOR. ELECTRICAL ® BLOWER COIL O EQUIPMENT CONN. QJ JUNCTION BOX Sal LIGHTS Qs EQUIPMENT SWITCH $ SWITCH D 20A-120V SINGLE RECEPTACLE 41) 20A -120V DUPLEX RECEPTACLE, WALL MOUNT +411* UNLESS OTHERWISE NOTED DUPLEX RECEPT. WALL MOUNT +18' 20A -120V UNLESS OTHERWISE NOTED ( DUPLEX RECEPT. FIXTURE MOUNT • DUPLEX RECEPT. FIXTURE HORIZONTAL • DUPLEX RECEPT. WALL HORIZONTAL • FOURPLEX SINGLE SPECIAL POWER RECEPTACLE, WALL MOUNT 448' 30A 208Vl1PH UNLESS OTHERWISE NOTED 6 SINGLE SPECIAL POWER RECEPT. FIXTURE MOUNT 30A-208V /1PH UNLESS OTHERWISE NOTED C) CONDUIT STUB 20A -125V DUPLEX RECEPT. FLUSH FLOOR BOX. UNLESS OTHERWISE NOTED DISCONNECT SWITCH 208/30- RUN DRAIN UNE OUTSIDE OF LOCATE IN COOLER COOLER TO NEAREST FL DRAIN. AT BL COIL 120/10 PROVARED DOOR PANEL - WALK -IN COOLER DETAIL (TYP) II A 4 NOTE: MECHANICAL • HOT WATER O COLD WATER ® DIRECT WASTE O WASTE CONNECTION A STEAM SUPPLY A STEAM RETURN D I GAS SUPPLY O GAS CONNECTION CI FLOOR DRAIN I1 FUNNEL FLOOR DRAIN ELI FLOOR SINK - - FLUSH MOUNTED SANITARY TYPE O AIR SUPPLY R'1 HYDRAULIC SUPPLY HYDRAULIC RETURN STEAM SHUT-OFF VALVE VENT PIPE BEVERAGE CONDUIT CHILLED WATER SUPPLY CHILLED WATER RETURN COOLER/FREEZER REFRIGERATION UNIT AIR VENT ELECTRICAL REQUIREMENTS COMPRESSOR BLOWER COIL THERMOSTAT (T) DRAIN UNE HTR. LIGHTS DOOR IITR. HEATED AIR VENT 208V/30, 1.OHP 120V, 4.0AMPS NjA N/A 120V, 80 W. EA. NjA N/A ALL FIELD WRING SUPPUED AND INSTALLED BY ELECTRICAL CONTRACTOR, INCLUDES HOOK -UP, INTERNAL AND EXTERNAL WIRING, CONDUIT AND FITTINGS AND LABOR TO MAKE COMPONENTS OPERATIONAL EXTEND ELECTRICAL FROM FACTORY INSTALLED INCANDESCENT FIXTURE TO FIELD INSTALLED FLUORESCENT FIXTURE(S) AT CEILING. LIGHT SWITCH IS FACTORY INSTALLED. EXTERNAL THERMOMETER MOUNTED BY K.E.C. AND WIRED BY ELECTRICAL CONTRACTOR. __ � - _ - - IT'-' I PLUG MOLD BY E.C., SEE SHEET #K2 FOR REQUIRED LOADS, PLUS ADD ADDITIONAL OUTLE U PLUG MOW BY EC., SEE SHEET #K2 FOR REQUIRED LOADS, PLUS ADD ADDITIONAL OUTLETS i 1 O L� I LA J PLUG MOLD BY E.C., SEE SHEET #K2 FOR REQUIRED LOADS, PLUS ADD ADDITIONAL OUTLETS 1/14, 1/2 H /CW, DOWN FROM CLG. THRU CHASE, TEE CW TO PRE -RINSE #55, 2 DIRECT WASTE - .. - F #14 ES. 1i (1) PLUG MOLD ABOVE TOP. (1) PLUG MOLD BELOW TOP 21 10 - . 1D 3' -3 i 188. 208 EC. TO TO S ID #27. (2) 6' EXH. CONN. VERIFY REQUIREMENTS - PE 3/4 GAS CONN. 0 5 100.000 BTU'S. DOWN FROM CEILING TFiLHNICAi. :.•St5•V ILL::.. • • l3 T PIPING 1 Va W GAS CONN. 0 BTU'S, 1/2 OWN FROM 5 KITCHE1" SCALE: #41, X GAS CONN. O 500,000 EN'S. 1/2 • H /CW. DOWN FROM CEILING ADD FLOOR SINK /41, 120/208V/30. 220V. DOWN FROM CEILING 2' -8 4.¢P I',.5 15.10 143. 2)2' TE CONN'S.. PLU H P LOCAL CODES .V/30 AMPS, STUB -UP f(4 5, /30, 5 EAMPS, STUB -UP 120V, PRE -WIRED DOOR PANELS. E R BLOWER COIL, FREEZER NLINE HEATER AND LIGHTS. V FROM CEILING - #20, 120V, 10.0A PS, 3/4 GAS CONN. 0 100.000 BTU'S, DOWN FROM CEILING - #211, (2) 6- EXH. CONN. VERIFY. REQUIREMENTS #37, 120V. 1.05KW +4B' #38, 120V. 1.25KW +48 #60. 20BV/10, 1HP, +18 EC. TO WIRE THRU SWITCH TO SOLINOID AND DISPOSER OS - DIRECT WASTE #60 1/2' H /CW +14 $43. 3/4 H /CW +14' T'-Er DATA 43, 3/4 H /CW +14- 14 2 - -8 #44. FAN SWITCH +50 BY EC. 145. do 4B. FLOOR SINK TIP_ (F.S.) }144. 3/4 HW +16', 120F. MIN. #44„ B's10' EXHAUST DUCT CONNECTION 0 1000CFM �- BLOWER COIL MAINLINE. `- RUN PRIOR TO WALK -IN BOX INSTALLATION. 5 WIRES FROM BLOWER COIL TO COMPRESSOR (LOCATED IN ITEM #51). ELECTRIC DEFROST : T _ If L1 i I L Ti L I 1 Li 1 I +78 ..18 [DOWN FROM CEUNG _ 1/4" = 1' -0" TRAINING ROOM 1 LL L I "U MO2--4008 ROUGH -IN PLAN (D 0 II W ll0II ei fjz __ ` N� VCF TUKNIILA r ■ JAN I PERMIT CENTER KC -1 - EQUIPMENT KC -2 - SCI-IEAULES KC -3 - UTILITIES KC -4 ELEVATIONS KC -B ELEVATIONS 11/5 /01 KC -3 1/•411 =11_ 011 PLUG MOLD 0Y E.G. CUPBOARD PER ARCHITECTURAL TYP. hadh ®d hadh9 PLUG MOLD BY E.G. TYP. —BANK OF DRAWERS TYP. O ELEVATION 1 SCALE: 3/8 " =1' -0" O ELEVATION SCALE: 3/8 " =1' -0" I =I had I a I j u 14i c 2 z u � O ELEVATION SCALE: 3/8 " =1' -0" ® ELEVATION SCALE: 3/8 " =1— 0" CUPBOARDS AND CADNET5 TYP. PER ARCHITECTURAL TYP. PLUG MOLD TYP. BY E.G. O ELEVATION SCALE: 3/8 " =1' -0" BLOWER COIL i . 1► II OOa 1O a s 000 a a a �OOO 5/5 UTENSIL HOOKS TYP. E FINISHED BACK 8 COMPARTMENTED PACKAGING (VERIFY) O ELEVATION SCALE: 3/8"=1.' — 0" <54 5/5 PPE CHASE ELEVATION SCALE: 3/8 " =1' -0" DISPOSER CONTROL (1 SHEET PAN STORAGE — ii BANK OF DRAWERS TYP. a �l I e I LEGS PINNED TO FLOOR TYP. WHERE NOT ATTACHED TO AN UNDERSHELF 1 4, O" 00 DISPOSER I CONTROL 15) 6 11 ELEVATIO N SCALE: 3/8 " =l' -0" 17) 15 1) N 4NIE' it . . [—TI TRASH GR OWNet PLUG MOL� BY E.G. PULL -OUT SHELF BLOWER COIL DRANUNE / ALL CUSTOM FABBICA - rEesc. GQUiP',MCWF P R GEBA 11P P (COVED M ANU FACTURES S HOP DR [ 814eur • aOEx C -i - EQUIPhTENT C -2 - SCHEDULES C -3 - UTILITIES C -4 - ELEVATIONS G -5 - ELEVATIONS tlp9RAt SET MM. MY. L In NMI PLUG MOLD 0Y E.G. CUPBOARD PER ARCHITECTURAL TYP. hadh ®d hadh9 PLUG MOLD BY E.G. TYP. —BANK OF DRAWERS TYP. O ELEVATION 1 SCALE: 3/8 " =1' -0" O ELEVATION SCALE: 3/8 " =1' -0" I =I had I a I j u 14i c 2 z u � O ELEVATION SCALE: 3/8 " =1' -0" ® ELEVATION SCALE: 3/8 " =1— 0" CUPBOARDS AND CADNET5 TYP. PER ARCHITECTURAL TYP. PLUG MOLD TYP. BY E.G. O ELEVATION SCALE: 3/8 " =1' -0" BLOWER COIL i . 1► II OOa 1O a s 000 a a a �OOO 5/5 UTENSIL HOOKS TYP. E FINISHED BACK 8 COMPARTMENTED PACKAGING (VERIFY) O ELEVATION SCALE: 3/8"=1.' — 0" <54 5/5 PPE CHASE ELEVATION SCALE: 3/8 " =1' -0" DISPOSER CONTROL (1 SHEET PAN STORAGE — ii BANK OF DRAWERS TYP. a �l I e I LEGS PINNED TO FLOOR TYP. WHERE NOT ATTACHED TO AN UNDERSHELF 1 4, O" 00 DISPOSER I CONTROL 15) 6 11 ELEVATIO N SCALE: 3/8 " =l' -0" 17) 15 1) N 4NIE' it . . [—TI TRASH GR OWNet PLUG MOL� BY E.G. PULL -OUT SHELF BLOWER COIL DRANUNE / ALL CUSTOM FABBICA - rEesc. GQUiP',MCWF P R GEBA 11P P (COVED M ANU FACTURES S HOP DR [ 814eur • aOEx C -i - EQUIPhTENT C -2 - SCHEDULES C -3 - UTILITIES C -4 - ELEVATIONS G -5 - ELEVATIONS tlp9RAt SET MM. MY. + ® 53 53) 1 1@' CAULK TABLE 2- 1 1/2' WALL BOARD FASTENERS ASREQD f_ 1 L I 1rr STUD VARIES 8° TO 12' ASREQD �� 4 � r ' ® STUD NOTCH FOR5TUDS .._. 7O " ``` �' STEEL CHANNEL L.ENGTHASREQ'D _ - FASTEN INTO STUDS WffHFLATHEAD SUSPENDED CEILING AND EXTRUDED TRIM --- FASTENERS SPLASH �. 11/2' TO 3' BY G.C. ,W 18 GA. S/S CEILING CLOSURE CK TO HOOD PE WELD BY K.E.C. ENCLOSURE 1112° ■ 0• I ■ �■ ■ �■ CORNER TABLE EDGE I I I I I WM VENTILATOR - - � / E \ HOOD COUNTER SUNK SCREWS NOTE: WALL BACKING FOR ALL SHELVES, SPLASHES, BRACKETS AND EQUIP. ATTACHMENT, FURNISHED & INSTALLED BY GENERAL CONTRACTOR, COORDINATED BY KITCHEN EQUIPMENT CONTRACTOR W CKJNG DETAIL I�I I I ELEVATION c CURB EDGE \ J NO Cry) E NO SCALE B ) NO SCALE A ►io sc�LE 1 SCALE: 3/8 " =1' - 0" VARIES 0 • FABRICATE / CENTER BRACKET BEHIND EA FRONT LEG AND W/REQ SECURE CH TO WALL 'D, / � F ASTEN ERS FOR MAX. HOLDING STRENGTH. 3/8' DIA. PEG HOLE OF 12 GA. 3/S \ ANGLE DETAIL FASTENERS SUSPENDED CEILING AND EXTRUDED TRIM CEILING ENCLOSURE, � � FASTEN TO WALK -IN PERIMETER. BY K.E.C. — FINISHED FLOOR BY G.C. — 7/S' THICK MARINE TYPE PLYWOOD WITH GALV. STEEL COVERING AT FREEZER. COOLER & FREEZER 4° THICK URETHANE WALL DOOR 141" FINISHED FLOOR SUSPENDED CEILING AND EXTRUDED TRIM BY G.C. EXISTING REEL ■ FASTENERS CEILING ENCLOSURE, FASTEN TO WALK -IN PERIMETER. BY K.E.C. FASTENERS Ur SLOPE COVED BASE BY G.C. S/S HEATED H WITH THRESHOLD FLOOR FLUSH WITH FIN. FLOOR BULWOSEATRAMP \�\�\ \\\��" == BY G.C. "` """ /� BY G.C. WALK -IN COOLER, r // 4° URETHANE BUILDING FLOOR - OVEN / \ N ENCLOSURE " 30 IkSPHALT PAPF_R -1/3 LAP NOTE FREEZER. / \ W ENCLOSURE VERIFY FLOORING TYRE WITH ARCHITECT COOLER/FREEZER FLOOR I H � No scams G SCALE N RACKET E F (C TYP. O ELEVATION SCALE: 3/8 " =1'— 0" DISPOSER TYP. CONTROL PRE -RINSE FAUCET - O ELEVATION 11 SCALE: 3/8" =1' -0" DRAM TAILPIECE. RUN DRAINLINE TO FLOOR SINK - FLOOR SINK TYP. -� BLOWER COIL DRAINLINE 5 FAN SWITCH BY E.G. 44 46 LJ rl BLOWER COIL LJ O 10 ELEVATION SCALE: 3/8 " =1' -0" 12 O ELEVATION SCALE: 3/8 " =l' 0" ELEVATIO N SCALE: 3/8 " =1' -0" INSULATED PAD ALL CUSTOM F A13 RICATED t OtPMENT PER GEBI; kPPROVED MANUFAGTOR"ERS S HOP , IDRP , WINCCS, II V w emx IIEr11311 Awvriafrw. CRR JAR I C 16,12 PERMIT CENTER KC -1 EQUIPMENT KC -2 - SCHEDULES KC -3 - UTILITIES KC -4 - ELEVATIONS KC -5 - ELEVATIONS a VIRT . ear Scab /4 = I' 0" '`ge 11/6/01 KC 5 1 "-7 PROJECT: CONTINENTAL MILLS TITLE R -102 FIRE SYSTEM LAYOUT DATE: 08/07/01 DWG: 8343 -1A REV: 09/27/01 H - H - 67' STANDARD FEATURES I_,..,- rx ^ ' °' °"° ^ °° ° °°'° w STANDARD FEATURES El T 60' S.S. FILTERS (KSA) 6 d d d 0 b b b -0 0 6 12' H -5 INCANDESCENT LIGHTS / / /// / / / / /OiY//H / /// CU CM MOUNTED IN KDS RISER, 67' 1 -3 GALLON REGULATED RELEASE 1 -TWO TANK ENCLOSURE W\ TWO 3 GALLON TANKS 1- DOUBLE TANK NITROGEN 0--0 i 4 4' 4 4 4 OPTIONS 7 INSULATION Q 1 ° p SUPPLY FIRE DAMPER 0 El SUPPLY FIRE DAMPER pn p<1 CARTRIDGE (73022) 7 z 2 H -1 12' H -1 H -2 126' 126' 1) ANSUL R -102 FIRE SYSTEM 2) THREE TANK SYSTEM 09 GALLON) 3) ALL 3/B' BLACK IRON PIPE W/ S.S APPLIANCE DROPS — 0 H -4 -_ 4)4 221 VVALVETIZE =7T j j — 2 H -2 _12 zz H -3 i 5 ' 1,1- 51' 6• ` _ FLUORESCENT LIGHTS 2 i ~ (N u 2 SNITCH PANEL IN (D FIRE PROTECTION IN <D FIRE PROTECTION IN (D IN <u # N (N a) u (N u ® ^� )j( 24' v/0 EXHAUST DAMPER v/ ENxAD$T DAMPER # v/0 EXHAUST DAMPER. v/ EEHAUST SAMPER 3. SIDE SKIRTS EXPOSED SURFACES . 4 S.S. SIDE SKIRTS 3'. 1 3 ' — I I V 260 260 2 60 (2I .2I 21 293 (2 ) r2 2) 230 230 230 2 2) 2> — CEILING CLOSURE �autilD::uw % - B O 0 - - B O I 0 � "`9A "' CEILING CLOSURE - J40� S 1E- 0 OVEN / 8343 -5 INSULATED BACKSPLASH CFM INSULATED BACKSPLASH PROJECT. CONTINENTAL MILLS ` 24• STAND -OFF' . I m 6 m # 6 0 0 OVEN OVEN CONVECTION OVEN 67' OVEN ALL 18 GA. 304 S.S. Ha /ton R s B 'III .l FRYER '— GRIDDLE GRIDDLE RANG RANGE OVEN ® I 0 I 'I J II ® B pp FRYER E p V V 7� � ,[T iI u ZT IT ll U l( 11 T7 fT • Na /fan MODEL: KVC ,,,,, ,,oi^ s a`w STANDARD FEATURES NC LEVEL. MODEL: KVC ^ ' °' °"° ^ °° ° °°'° w STANDARD FEATURES FLUORESCENT LIGHTS 60' S.S. FILTERS (KSA) 6 7 60' {--- S.S. FILTERS (KSA) 6 INCANDESCENT LIGHTS H -5 INCANDESCENT LIGHTS 32 Db 7 OPTIONS 7 INSULATION # INSULATION SUPPLY FIRE DAMPER i SUPPLY FIRE DAMPER 126' 53 19' 5' _- 12' 59.5 7' 1 r^ ® 51' 24' X 126' 54.5' 17' _12 • \ 59 5 ' 1,1- 51' 6• ` OPTIONS OPTIONS FLUORESCENT LIGHTS 2 FLUORESCENT LIGHTS 2 SNITCH PANEL SNITCH PANEL FIRE PROTECTION # FIRE PROTECTION U.L. LISTED # U.L. L. LISTED 7 ® ^� )j( 24' v/0 EXHAUST DAMPER v/ ENxAD$T DAMPER # v/0 EXHAUST DAMPER. v/ EEHAUST SAMPER 3. SIDE SKIRTS EXPOSED SURFACES . 4 S.S. SIDE SKIRTS 3'. 1 3 ' — I I E: — CEILING CLOSURE \ PORTS \` f I I 3'_... r^ II i.5, PERF FRONT I 0 � "`9A "' CEILING CLOSURE DVL NO. STD. BACKSPLASH EXHAUST AIR INFORMATION STD. BACKSPLASH 8343 -5 INSULATED BACKSPLASH CFM INSULATED BACKSPLASH PROJECT. CONTINENTAL MILLS STAND -OFF 24• STAND -OFF' -- CFN MATERIAL MATERIAL E %POSED SURFACES IB GA. 304 S.S. # E %POSED SURFACES 18 GA. 304 S.S. 3' ,• 67' R[ -FUSE ALL 18 GA. 304 S.S. Ha /ton 3' I RE - F■SE, \ ALL 18 LA. 301 S.S. COMMENTS. H -1 OF FOUR HOODS END TO END P. HACK TO BACK WITH KDS IN BETWEEN. COMMENTS. TYP OF (3) HOODS END TO END AND BACK TO BACK WITH KDS IN BETWEEN. I 24' 1 \r/ i pAB CppTWF -JE • j DRTS AIR I � = 7 18' `\ 1 ],5• PERF FRONT 24' III \--'-'-'-' � / TAB =Xs MTURE - JE P S RSA T _ ' y I 18 LS" PERF FRONT REV, 05!27/01 ® r �� @0 REV: 09/27/01 �I mwm Pi -ie PATE DWG. N0. ITEM N13AM . EXHAUST A INFORMATION DATE DWG. NO. ITEM Na EXHAUST AIR INFORMATION 08/07/01 8343 -1 H -1 CFN SP 08/07/01 8343 -2 H -2,3,4 CFN SP PROJECT. CONTINENTAL MILLS 2541 EA .25 SUPPLY AIR INFORMATION PROJECT. CONTINENTAL MILLS 2250 EA 6750 TOTAL 20 SUPPLY AIR INFORMATION CFM SP CFM sP LOCATION TUKWILLA, WA. CAPTURE AIR INFORMATION 945 .25' TI LOCATION. TUKWILLA, VA CAPTURE AIR INFORMATION 945 EA 2835 TOTAL ,2c,. EFM SP CFM 1 SUBMITTED BY. HALTON CO. 116 .68' Halton SUBMITTED BY:'. HALTON CO. 116 E P OT 348 TOTAL H . / /.�, MODEL: KVC ,,,,NTrm. AT TRH Rr R�, °°' STANDARD FEATURES NC LEVEL. 60' S.S. FILTERS otSA) 8 FLUORESCENT LIGHTS 2 28 Db H-3 7 INSULATION # SUPPLY FIRE DAMPER # H -5 2925 32 Db OPTIONS INCANDESCENT LIGHTS SWITCH PANEL FIRE PROTECTION UL LISTED V � n �1f1' /0 EXHAUST DAPPER V/ EXHAUST DAPPER 159' 69' 7 IICC 28 , SIDE SKIRTS 12' CEILING CLOSURE STD. BACKSPLASH INSULATED BACKSPLASH STAND -OFF MATERIAL 33 3. EXPOSED SURFACES . 4 S.S. 3'. 67 RE USE E: L REVS 09/27/01 \ PORTS \` . ILTERS II i.5, PERF FRONT I 0 � "`9A "' DATE DVL NO. ITEM NO EXHAUST AIR INFORMATION 08/07/01 8343 -5 H -5 CFM SP PROJECT. CONTINENTAL MILLS 2925 24• .SUPPLY AIR INFORMATION -- CFN SP CAPTURE AIR INFORMIATMN 1165 25' LOCATION TUKWILLA, WA C. SUBMITTED BY. HALTON CO. 143 .68'. Ha /ton EXHAUST SOUND LEVEL DATA HOOD . EXHAUST CFM NC LEVEL. N -1 2541 30 Db H -2 2250 28 Db H-3 2250 28 Db H - 4 2250 28 Db H -5 2925 32 Db PROJECT: CONTINENTAL MILLS DATE: 08/07/01 DWG: 8343 -5A REV: 09/27/01 REMOTE MOUNTED: (1) REGULATED RELEASE I) ANSUL R -102 FIRE SYSTEM 2) TWO TANK SYSTEM (6 GALLON) (1) EXTRA TANK 3) ALL 3/8' BLACK IRON PIPE W/ S.S APPLIANCE DROPS — 43GAS VACVE 77? 260 260 r2> <2) OD I GRIDDE N0V '1 158' H - 5 230 230 t2) r2) FRYER TYPICAL "KVE" BACK TO BACK INSTALLATION CAPTURE -JET FAN 102' 84' 70P OF Ho D 120' MIN U.L. LISTED UP -BLAST EXHAUST FAN IN DROP CEILING Pala /ton F ! .fi! 6 " SUBMITTAL RE Y �E W APPVO+m AS MIMED D xAPP40YED AS NOTED T ": MT APPROVED D RIMMED FON ODRRECTIONS D 1rslBwt ir� 11 AM3IEVF 91" ,: M M A T IONS. CO NIB DF CJ:.. .15 . _ATE. +TIFNS F NOD DIL IENi'!Y PMfrc.. ,1 MO NOD NY01SEx.S Ant ri'- s rs r.r;P.B+6wDrD.. . Di0_, "2a O i (208) J-vYlJ NY P/ GEORGE E BUNDY A IO?H N.E RAVENNA ELF. ( @ S1ATTL:, TNSHIN100: 32171 PROJECT. CONTINENTAL MILLS DATE. 08/22/01 DWG: 8343 -1C REV. 09/27/01 Ha /tan 'HANGER BRACKET LAYOUT HOODS #1, 2, 3 4 126.0 t : 006 -1(400 -0 BAEOASNOTED ( )NOTAPPROVED- CORRECT &RESUBMIT This review does not relay the sup,. from nisponsibilly tor worn, accuracy or ac >ts eline.6rnq quantifies or coNori Nhce Mln the mimaueoo,R,ent GLY NS T•- ON - PROJECT: ` CONTINENTAL MILLS TITLE: HOOD LAYOUT LOCATION: TUKWILLA, WA DATE: 08/07/01 4.5' 67.0' RECEIVED NOV 27 2001 GL Y RECEIVED CITY OFTUKKWILA PERIMT cENTER REV DATE: 09/27/01 DWG #: 3 4 3 A UTILITY CONNECTIOINS /LOCATIONS ITEM# ITEM DESCRIPTION HOT DIA WATER CONN. TYPE COLD DIA WATER CONN. TYPE MBH GAS DIA CONN. TYPE VOLTAGE ELECTRICAL PHASE AMPAGE GONE TYPE SUPPLY STEAM LBS /HR :ONO RETURN 29 GRIDDLE ( ---- 3/ 4 cgc. ` p 220 1 3,6 CEP 30 GRIDDLE % Y R R R RRR RISER i % • • • 0 0 Y O 4 /� 7 Y 0 d • C ELE CTRI GL r< CTR z RISER / 208 3 33.3 CEP ir (.l)24PW/3`l' I. Kw ?atm -. 31 ROTISSERIE O O 208 3 22.8 CEP 0 o 32 HOT TOP RANGE 40 1' 0D 33 CONSUMER RANGE H -1 — H - 2 220 1 300 C &P. 34 CONSUMER OVEN 220 1 11.8 CEP 35 CONSUMER OVEN 220 1 1L8 CEP 36 CONSUMER CONV. OVEN ' 220 1 11.8 CMP 20 STANDARD OVEN 40 3/4' OD 22 STANDARD DBL. OVEN 80 3/4' 0D 21 DBL. CONY. OVEN 115 3/4' RB 120 1 7.4 CEP 21 DBL. CONV. OVEN 115 3/4' OD 120 1 7,4 CEP 23 CONVECTION OVEN 55 1/2' on .120 1 7.1 CEP 23 CONVECTION OVEN 55 1/2' OD 120 1 7.1 CEP 24 FRYER 208 3 472 CEP 25 FRYER 208 3 192 C&P. 26 KETTLE 1/2' QD 1/2' QD 208 3 17.5 CEP CONVENIENCE OUTLET 120 1 20 .DUPLEX CONVENIENCE OUTLET 120 1 20 DUPLEX SUB TOTALS 5 00 208/3 140 220/120/1 138 RESERVE FOR FUTURE '.. 200 208/3 ss 220/120/1 56 TOTALS w /20% elect, safety 700 208/3 235 220/120/1 235 SERVICE SIZE 1 '.., NPT - -oti I NPT 11/4' NPT 208/3. 250 240/120/1 250 30.0' 27 120/1, 15AMP CONVENIENCE OUTLET 3/4' GAS QD 3/4' GAS QD 3/4' GAS QD x.EEXTRA CUTOUTS FOR GAS AND ELECTRICAL SERVICE TO BE PROVIDED WITH COVER PLATES ?? ALL HOSES AND CORDS TO BE 60 "L. 54" RESTRAINING CABLES TO BE USED ON APPLIANCES, PROJECT' CONTINENTAL MILLS TITLES KDS LAYOUT DATE 08/06/01 DWG 8343 REV 08/23/01 RISER HEIGHT= CLG HEIGHT + 2' 24' -- -30' -- 252' PEDESTAL —30'— 16 GA, 304 S.S. CONSTRUCTION ACCESS PANEL Ha /tan 1/2' GAS QD 1/2' GAS QD SEE DETAIL LLB l 120/1, 15AMP CONVENIENCE OUTLET ELECTRICAL CORDS Ha /tan KDS KITCHEN DISTRIBUTION SYSTEM ENTERING ELECTRICAL FROM BLD SOURCE 7 ELECTRIC GAS VALVE WATER HOOKUP 011= QUICK DISCONNECT WHOSE C &P= CORD & PLUG NPT= NATIONAL PIPE THREAD MAIN CIRCUIT BREAKER CONTROL CIRCUIT BREAKER GAS. CONTROLS CIRCUIT BREAKER STATUS LIGHTS (OPTIONAL, EXHAUST FAN SWITCH (OPTIONAL) VENT LIGHT SWITCH GAS /STEAM HOOKUP DETAIL 'A' TYPICAL CONTROL PANEL ID J O IDO t(CIAWAMIAIMEMER " VW. ID GAL. URU TRC RETIRE I NR YR ACME I I ANSUL L❑CATI ❑N MODEL: KBD DATE 09/12/01 DWG, N0.', 8343 -3 PROJECT. CONTINENTAL HILLS LOCATION TUKWILLA, WA.. SUBMITTED BY, HALTON CO. u�T ITEM N6 'L• 19• 17' 12' 12' QUANTITY TAG H-1 H -2,3,4 MATERIAL FRAME 16E8 CONT. RELIED ADJUSTABLE PANEL 18 GA SS. Halton Mz '&' TYPICAL SERVICE LAYOUT FOR UTILITY DISTRIBUTION SYSTEMS JAN JAN PERWIYCO4T31 H Itan PROJECT: CONTINENTAL MILLS TITLE: KITCHEN DISTRIBUTION SYSTEM LOCATION: TUKWILLA, WA REV DATE: 09/11/01 �d N DATE: 08/06/01 DWG # :v v v 126,0' ® ® ® H -4 126,0' H -3 C a i/ ( ---- 3/ 4 cgc. ` p % Y R R R RRR RISER i % • • • 0 0 Y O 4 /� 7 Y 0 d • C ELE CTRI GL r< CTR z RISER / �1 V Y Y Y Y !• Y Y n� ir (.l)24PW/3`l' I. Kw ?atm -. O O n� O O 0 o H -1 — H - 2 30.0' 27 120/1, 15AMP CONVENIENCE OUTLET 3/4' GAS QD 3/4' GAS QD 3/4' GAS QD x.EEXTRA CUTOUTS FOR GAS AND ELECTRICAL SERVICE TO BE PROVIDED WITH COVER PLATES ?? ALL HOSES AND CORDS TO BE 60 "L. 54" RESTRAINING CABLES TO BE USED ON APPLIANCES, PROJECT' CONTINENTAL MILLS TITLES KDS LAYOUT DATE 08/06/01 DWG 8343 REV 08/23/01 RISER HEIGHT= CLG HEIGHT + 2' 24' -- -30' -- 252' PEDESTAL —30'— 16 GA, 304 S.S. CONSTRUCTION ACCESS PANEL Ha /tan 1/2' GAS QD 1/2' GAS QD SEE DETAIL LLB l 120/1, 15AMP CONVENIENCE OUTLET ELECTRICAL CORDS Ha /tan KDS KITCHEN DISTRIBUTION SYSTEM ENTERING ELECTRICAL FROM BLD SOURCE 7 ELECTRIC GAS VALVE WATER HOOKUP 011= QUICK DISCONNECT WHOSE C &P= CORD & PLUG NPT= NATIONAL PIPE THREAD MAIN CIRCUIT BREAKER CONTROL CIRCUIT BREAKER GAS. CONTROLS CIRCUIT BREAKER STATUS LIGHTS (OPTIONAL, EXHAUST FAN SWITCH (OPTIONAL) VENT LIGHT SWITCH GAS /STEAM HOOKUP DETAIL 'A' TYPICAL CONTROL PANEL ID J O IDO t(CIAWAMIAIMEMER " VW. ID GAL. URU TRC RETIRE I NR YR ACME I I ANSUL L❑CATI ❑N MODEL: KBD DATE 09/12/01 DWG, N0.', 8343 -3 PROJECT. CONTINENTAL HILLS LOCATION TUKWILLA, WA.. SUBMITTED BY, HALTON CO. u�T ITEM N6 'L• 19• 17' 12' 12' QUANTITY TAG H-1 H -2,3,4 MATERIAL FRAME 16E8 CONT. RELIED ADJUSTABLE PANEL 18 GA SS. Halton Mz '&' TYPICAL SERVICE LAYOUT FOR UTILITY DISTRIBUTION SYSTEMS JAN JAN PERWIYCO4T31 H Itan PROJECT: CONTINENTAL MILLS TITLE: KITCHEN DISTRIBUTION SYSTEM LOCATION: TUKWILLA, WA REV DATE: 09/11/01 �d N DATE: 08/06/01 DWG # :v v v UTILITY CONNECTIOINS /LOCATIONS . ITEM. ITEM DESCRIPTION HOT DIA WATER CONN. TYPE COLD MA WATER CONN. TYPE MBH GAS 01A CONN. TYPE VOLTAGE ELECTRICAL PHASE AMPAGE CONN. TYPE SUPPLY STEAM LBS /HR COND RETURN 2 9 GRIDDLE ., 220 - 1 3.6 CLP- k ; 30 GRIDDLE 208 3 33.3 CEP 31 ROTISSERIE 208 3 22.8 CLP 32 HOT TOP RANGE 40 . 1' OD .. - 33 CONSUMER RANGE 220 1 - 30.0 CLP - 34 CONSUMER OVEN 220 I 11.8 CEP 3 5 CONSUMER OVEN 3 6 CONSUMER CONY. OVEN 2 0 STANDARD OVEN 40 : .3/4' OD - - 2 2 STANDARD DBL. OVEN 80 . 3/4' OD - y : - 21 DBL. CONY. OVEN 115' 3/4' : OD - 120 1 7.4 = CEP - - 21 DBL. COW. OVEN 115 3/4' OD 120 1 7.4 CEP 2 3 CONVECTION OVEN 55 1/2' 0D 2 3 CONVECTION OVEN 55 - 1/2' 0D 24 FRYER - 208 3 472 - C &P 25 FRYER 208 3 19.2 CEP - 2 6 KETTLE 1/2' OD 1/2' OD 208 - 3 17.5 . .CEP - CONVENIENCE OUTLET 120 - 1 - 20 DUPLEX CONVENIENCE OUTLET 120 1 20 DUPLEX SUB TOTALS 500 - 208/3 140 220/120/ 100.2 RESERVE FOR FUTURE 200 20e /3 56 220/120/ 40 TOTALS w /20% elect. safety 700 208/3 235 220 /120/1 168 SERVICE SIZE l{ m'� NPT 3 41 i1 e–" NPT 1 1/4' NPT 208/3 250 240 /120/1 180 jE J/ 31.0' 0 120/1, 15AMP 29 30 CONVENIENCE OUTLET 3/4' GAS TYP 24.0'— / 1' /GAS 0 158.0' 34rIc y' -1/2' GAS 0 �od00000 F 31 3 34 21 24 25 26 35 23 36 (1i)263 V/6' 1 n pCOUj 1/2' HOT WATER r1 /2' COLD WATER 3/4' GAS I 1/2' GAS (4 2.0' 36.0' --- r‘. 120/1, 15AMP — CONVENIENCE OUTLET * *EXTRA CUTOUTS FOR GAS AND ELECTRICAL SERVICE TO BE PROVIDED WITH COVER PLATES ** w *ALL HOSES AND CORDS TO BE 60 "L. 54 "L RESTRAINING CABLES TO BE USED ON APPLIANCES. PROJECT. CONTINENTAL MILLS TITLE. KDS LAYOUT DATE. 08/06/01 DWG= 8343 REV. 09/11/01 RISER CLG H'. PEDESTAL Halton KITCHEN DISTRIBUTION SYSTEM ENTERING ELECTRICAL FROM BLD SOURCE ELECTRIC GAS VALVE /1 WATER HOOKUP KDS GAS /STEAM HOOKUP DETAIL 'A' TYPICAL CONTROL PANEL corvErnw aT(wc. 0 " CIAVNI.c *nc f-I cmvXAMM ay. . • DD= QUICK DISCONNECT w /HOSE C&P= CORD & PLUG NPT= NATIONAL PIPE THREAD H Icon REV. 11/13/01 4146 TYPICAL SERVICE LAYOUT FOR UTILITY DISTRIBUTION SYSTEMS 40' — 8.5'— WALL STYLE CI .ASE RECENEID CITY OF TUKWtLA Ha /tan (OPTIONAL) EXHAUST FAN SWITCH (OPTIONAL) VENT LIGHT SWITCH 0mE. mu 10 MUT 1411q-N frI2Itfl REV DATE: 11/13/01; PROJECT: CONTINENTAL MILLS. TITLE: KITCHEN DISTRIBUTION SYSTEM. LOCATION: TUKWILLA, WA DATE: 08/07/01 DWG # ,8 3 4 3 C PERMITU Y€ - 24 / 16 G A. 158' 304 S S. CONSTRUCTION ,ACCESS PANEL —24' x. HEIGHT TIGHT • 2• 24' — r i .—' r Il l k ; u u jE J/ 31.0' 0 120/1, 15AMP 29 30 CONVENIENCE OUTLET 3/4' GAS TYP 24.0'— / 1' /GAS 0 158.0' 34rIc y' -1/2' GAS 0 �od00000 F 31 3 34 21 24 25 26 35 23 36 (1i)263 V/6' 1 n pCOUj 1/2' HOT WATER r1 /2' COLD WATER 3/4' GAS I 1/2' GAS (4 2.0' 36.0' --- r‘. 120/1, 15AMP — CONVENIENCE OUTLET * *EXTRA CUTOUTS FOR GAS AND ELECTRICAL SERVICE TO BE PROVIDED WITH COVER PLATES ** w *ALL HOSES AND CORDS TO BE 60 "L. 54 "L RESTRAINING CABLES TO BE USED ON APPLIANCES. PROJECT. CONTINENTAL MILLS TITLE. KDS LAYOUT DATE. 08/06/01 DWG= 8343 REV. 09/11/01 RISER CLG H'. PEDESTAL Halton KITCHEN DISTRIBUTION SYSTEM ENTERING ELECTRICAL FROM BLD SOURCE ELECTRIC GAS VALVE /1 WATER HOOKUP KDS GAS /STEAM HOOKUP DETAIL 'A' TYPICAL CONTROL PANEL corvErnw aT(wc. 0 " CIAVNI.c *nc f-I cmvXAMM ay. . • DD= QUICK DISCONNECT w /HOSE C&P= CORD & PLUG NPT= NATIONAL PIPE THREAD H Icon REV. 11/13/01 4146 TYPICAL SERVICE LAYOUT FOR UTILITY DISTRIBUTION SYSTEMS 40' — 8.5'— WALL STYLE CI .ASE RECENEID CITY OF TUKWtLA Ha /tan (OPTIONAL) EXHAUST FAN SWITCH (OPTIONAL) VENT LIGHT SWITCH 0mE. mu 10 MUT 1411q-N frI2Itfl REV DATE: 11/13/01; PROJECT: CONTINENTAL MILLS. TITLE: KITCHEN DISTRIBUTION SYSTEM. LOCATION: TUKWILLA, WA DATE: 08/07/01 DWG # ,8 3 4 3 C PERMITU Y€ -