Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M02-031 - UNITED RENTALS
UNITED RENTALS 17700 W VALLEY HY Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: Signature: Print Name: doc: Mech City of Pukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 3623049057 17700 WEST VALLEY HY TUKW UNITED RENTALS 17700 WEST VALLEY HY, TUKWILA, WA FORTE RONALD M PO BOX 816, RENTON WA BARRY ANDERSON 7649 S 180 ST, KENT, WA PERFORMANCE HEATING 7649 S 180 ST, KENT WA Contractor License No: PERFOHA15ORT DESCRIPTION OF WORK: REPLACE EXISTING 40 TON ROOFTOP VAV COOLING UNIT WITH NEW OF LIKE CAPACITY Value of Construction: $34,623.00 Fees Collected: Type of Fire Protection: Uniform Mechnical Code Edition: Permit Center Authorized Signature: 1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the rformancp of work. I am authorized to sign and obtain this mechanical permit. 4 / uGl't 514iP,1-1'2e4 MECHANICAL PERMIT MO2 -031 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 - 251 -0356 Phone: 425 251 -0356 Expiration Date: 04/28/2002 MO2 -031 02/19/2002 08/18/2002 ti --/` t_ Date: Date: $115.81 1997 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 02 -19 -2002 doc: Conditions City of Tukwila Parcel No.: 3623049057 Address: 17700 WEST VALLEY HY TUKW Suite No: Tenant: UNITED RENTALS • PERMIT CONDITIONS Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Number: MO2 -031 Status: ISSUED Applied Date: 02/07/2002 Issue Date: 02/19/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (248 - 6630). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 11: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1900. 12: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1- 5.5.4) 13: Local U.L. central station supervision is required. (City Ordinance #1900) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 16: Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1900) 17: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1900) 18: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) rs +rr+mw�ar.. tuw+ .•c, et aMr+vrw• <an ,"*9n:.J... nU MO2 -031 Printed: 02 -19 -2002 19: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 20: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 21: In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) 22: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. (City Ordinance #1900). 23: Duct detectors shall send a supervisory signal only upon activation. 24: ** *ELECTRICAL * ** UFC Article 85 - NPFA 70 - NEC 25: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) 26: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 27: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 28: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575- 4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Akirk- de Date: 2 MO2 -031 Printed: 02 -19 -2002 re � 0 0 2 co W O g Q uj W U 0 . O N' 0 t— W tlJ . u' O W Z UN O Project Name- /Tenant: Un►L° Re.K61S Signature: Value of echa ical Equipment: a 62-3 = Site Address : 17700 (Ajgcl" VALLe4 /4w- City State/Zip: 174KwitA /.N 98I8S Tax Parcel Number; -- 623c' -ejos7 Property Owner: 1Zoe■ F r+e. ara Phone: (4 - 25)25 -01 - Ce Phone: (877) 969 -4040 Street Address: /� 033 A/• G O A City State/Zip: a I < I. D g3e3s- Fax #: ( ) Contrdctor: Pe.r.PtitrIlletflte n /� o y Phone: (- 2S 25 - o'i;G ' Street Address: J 76 4 ! S . ISott S ,L. City State/Zip: Kew).- 98032 Fax #: (4 S'l at' l - o2-e,° Contact Person• ^^ Vaf / 1+r'c e rso r\ ) (A- Phone: (425 ) 25I - 0 3S - 00 Street A d ss: 7 q S'. Ig ,76( s+. City State/Zip: KrK 4 w 4 9eo - Fax #: (.1.2- ) 2,5 ( - 0200 BUILr OW ER UTHORIZED AGENT: Signature: Date: ,2. t Print name: i ara Phone: (4 - 25)25 -01 - Ce Fax #: {4-25 2 . 6 7 - o 2 $`" Address: - 7&4q S. te00..q Cit wil- 93072. CITY OF ` `JKWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 R STAFF USE ONLY • Protect Number. � 0 � 'O � Permit Number. Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): Replace_ �exrsll-r`rt�c 40 -t -art, t^efQ fdr '/4V cookki, %714 Hew /kec c;+. Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: g - -o 2_ Application taken by: (initials) 11/2/99 meth permil.doc ✓ ✓ Submittal Requirements Floor plan and systerin layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) ,/ Details and elevations (for roof mounted equipment) and proposed screening v Heat Loss Calculations or Washington State Energy Code Form #H -7 / . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. ,./ Structural engineer's . analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. t om, rt ' Mechanical Permits 11/2/99 ,Blscpnu.dac COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change -out or replacement of existing mechanical equipment 1 Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3623049057 Permit Number: MO2 -031 Address: 17700 WEST VALLEY HY TUKW Status: APPROVED Suite No: Applied Date: 02/07/2002 Applicant: UNITED RENTALS Issue Date: Receipt No.: R020000228 Payment Amount: 115.81 Initials: SKS Payment Date: 02/19/2002 10:51 AM User ID: 1165 Balance: $0.00 Payee: PERFORMANCE HTG & AC TRANSACTION LIST: doc: Receipt Payment Check 18714 115.81 ACCOUNT ITEM LIST: Current Pmts Amount MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Type Method Description Description Account Code 000/322.100 92.65 000/345.830 23.16 Total: 115.81 400` 02/21 9716 TOTAL 1.15.81 Printed: 02 -19 -2002 INSPECTION RECORD Retain a copy with permit . 1NSPE •N NO. ITY'OF TUKWILA BUILDING DIVISION 6300 Soudicenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 P kte - illy //t Special Instructions: ,' • Tyne of Inspection: mr)kle-- ,Sh I vino Dateit / /3 / J- Daterctr Requester: „ UP Ph 7 o 47 ( 35& Apkroved.Per applicable codes. Corrections required prior to approval. COMMENTS: rv\A °elm. s ' • ' ctor: 7.00 REINSPECTION E REQUIRED. Prio aid at t 300 Southcenter Blvd., Suite 100. Ipt No.: Date: 0 to inspection, fee must be all to schedule reinspection. Date: Project:;; _;:,.; : =%itJ/ •:: .. r ( Type of Inspection: .'S4.t©.. 5 LOUJL Address:- ':;- ..: .• • . , , Date Called: 9 ~� Special Instructions j F S� Qa Date Wa ed: ^ O� -17 a;m. Requ ster: J& FF ./T4 -." ` X1&1/6 Phone No: li 5 a5'/ — 035 INSPECTION RECORD Retain a copy with permit INSPECTION NO. IT rOF �� TUKWILA BUILDING DIVISION 300 #100, Tukwila, WA 98188 Approved'per codes. Inspec .r celpt No.::' (206)431 -3670 c orrections required prior to approval. Dat 47.00 REINSPECT!e FEE REQUIRED. Pri r to inspection, fee must be paid at b300.Southce ter Blvd., Suite 100 Call to schedule reinspection. Date: COMMENTS: Type of I pection: ; I N ) L AA.) G 7 ' ,4Z ( A Address: /77 / (1,� MOO W. Valley t ... �._. a k J- of a Requester: Ed ut kW ...ve-tu-A___I � `' A e IA.A. L 1\ 14 , ,..„ r - 1 .., t.,0.1, cceitcaziet4, 9 , ( k label t- Ur A. ( -fauu 10 tZ1A4.j Project: GG iebn Type of I pection: Address: /77 / (1,� MOO W. Valley Date called: 7 - / 1- D) Special instructions: CCII 01/ 'Or Ds/ 6356 0Jq) Date wanted: a Requester: Ed ut kW Phone:25 0 C di o INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 0 Approved per applicable codes. 'orrections required prior to approval. $47.00 REINSPECTION F E REQUIRED. Prior t inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to s edule reinspection. Receipt No: Date: D 3 l PERMIT NO. (206)431 -367 Date: /Z - 0 2.- • • • wrr .• eso., irAmr,7774772 t ,, 77-4, - 4 7 7" 1 4 r Projec Name I/AU Tt i Address ,Retain current inspection schedule q,Neds shift inspection Approved with correction notice issued Sprinklers: • Fire Alarm: Hood & Duct: Halon: Monitor: HiM/01-7Laeil Pre-Fire: Permits: :• •Authorized Signature FINALAPP.FRM 0 City of Tukwila .,----'• / ( Fire Department Thomas P. Keefe, Fire Chief / 7(, VA //t.--7 Approved without correction notice TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 / 1 4 6 0 Steven M. Mullet, Mayor Permit No. Suite # 9 / 4 422-- Da e / T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 £e'd 1H101 LIYORK' It' T/rne to Get Comfortable" Project Name UNITED RENTALS Architect Engineer Purchaser PERFORMANCE HEATING Submitted By FAMILIAN HVAC QUANTITY: UNITS DESIGNATION: Schedule No: [t RETURN AIR SUPPLY AIR 3 1518" FLANGED { FITTING A B ASE RAIL 1.1 DETAILA (DRAIN CONNECTION) VARIABLE VOLUME UNIT WITH FACTORY INSTALLED VFD Order No 83" _ 3&59• ' �''�- 127.5" r 240" 4 5" c. BASE RAIL MILLENNIUM 03-5/9" —�1 3-1/16" 646" ftT-- Me FP DETAIL 13 (ELECTRICAL CONNECTION) FOR COOLING ONLY AND ALL HEATING APPLICATIONS ESP2001 V2.6 Mitten 2001 Siabeeet to change without notice • Choc* local codes U'*J RTU - i FILE COPY 0-1/4" } Date 01/23/2002 Page 2 Model No: Y14ACO4M8KAGBB DETAIL C (GAS CONNECTION, THROUGH CURS) RECEIVED CITY OF TUKWILA i s, / Lu PERMIT CENTER FRONT 1 -1H "FPT 4518" 3:11t IN — mote Hces must be trilled et lob sae. a; + e A Pevd-ki s RTt 6NIYORIC ltt Time to Get Comfortable" MILLENNIUM VARIABLE VOLUME UNIT WITH FACTORY INSTALLED VFD Date 01/23/2002 Page 1 Order No Project Name UNITED RENTALS Architect Engineer Purchaser PERFORMANCE HEATING Submitted By FAMILIAN HVAC QUANTITY: 1 UNITS DESIGNATION: Schedule No: 40T VAV PKG NC Model No: Y14ACO4MAKAGBE COOLING FORMANCE Total Capacity Sensible Capacity Efficiency (at ARI) Part Load Efficiency Outdoor D8 Temp Entering D8 Temp Entering WB Temp Leaving DB Temp Leaving WB Temp Power Input (w /o blower) Elevation 504 391 9.5 9.7 95.0 80.0 87.0 57.3 57.0 48.40 0 MBH MBH EER 1PLV F F F F KW Ft SUPPLY AIR BLOWER PERFORMANCE Total Supply Air Outside Air External Static Pressure Supply Duct Connection Retum Duct Connection Blower Speed Motor Rating Brake HorsePower Power Input (blower only) 16000 CFM 0 CFM 2.00 IWG Bottom Bottom 815 R 25 HP 18.47 BHP 14.82 KW EXHAUST AIR BLOWER PERFORMANCE Exhaust Air External Static Pressure Blower Speed Motor Rating Brake HorsePower Power Input (blower only) 12000 CFM 0.60 IWG 889 RPM 15 HP 8.88 BHP 5.44 KW ELECTRICAL DATA Power Supply 480 -3-60 Total Unit Ampacity 146 Amps Maximum Overcurrent Device 175 Amps DIMENSIONS & WEIGHT Height 64 in Width 240 in Depth 92 in Total Weight (incl factory options) 5885 Lbs CLEARANCES Front 80 in Back 80 in Bottom' 0 in Top 120 in Left Side (filter access) 80 in Right Side (outdoor coil) 80 in Note:: Units must be Installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. ISO 9001 CI RTt Ptae GENERAL FEATURES - 9.5 EER. - ETL listed. - ISO 9001 certified. - Single curb size. - Double will construction provides superior cleanability and structural Integrity. • Hinged access doors provide easy service access to all components on both sides of the unit. - Industrial duty hermetic scroll compressors are efficient, quiet and fellable. - Sloped, stainless steel drain pan capable of draining more than 3 gallons per minute. Removable for easy cleaning. Stainless construction delivers long life. Muftlple cooling circuits provide outstanding part load performance, ideally suited for lower load days. - Interlaced evaporator coil provides larger heat transfer area at part load. - Condenser coils angled to protect them from hail, shipping and handling damage. - Single point power connection for easy installation. - Through - the -curb or through -the -base electrical connections are standard. • Retractable outside air hoods rotate into place from the shipping position, installing In minutes without fit-up in lifting problems. - Powder paint with en industry leading 750 hour salt spray rating offering superior cabinet life. - Mechanical cooling down to 40 degrees F (0 degrees F with condenser pressure control accessory) and up to 120 degrees F. 1 1/2 ' Insulation between the sheet metal skin surfaces protects the unit from sweating and delivers higher efficiency. • Sloped unit roof with specifically designed "drip lip" keeps the rain water from steaming down the side of the unit. • High and low pressure switches and a loss of charge switch protect the refrigeration systems. • Special polyurethane sleeves protect small diameter evaporator distributor tubing from rubbing together, giving longer life. • Fully factory packaged and run - tasted. - One -year compressor warranty. - One -year warranty on all other parts. . ,n ESP2001 V2.6 M rch 2001 Sub)ct to cnanga without notice • Check local codas L4 t+ J teb4b A e 1058 1 C O A 11 2 1108 e c 1 89 0 94 1220 A .0 1153 1203 1347 • e 1088 1153 1173 1317 C 1303 1398 1437 1457 20'd 11j101 036 - 21091.002 Rev A (0601) OLE 55: UNIT CORNERWEIGHT UNIT DESCRIPTION S A11C UNIT WITH 5C0/10/M =M B UM UN ft W1tN Economizes AND GA7 011 I) LiC71sC NEAT exec law Wrni EeaMOYRis MO GOIldarOANIMIO )ET AND POW{I) EXNAUIT T ABLE 56: INDOOR SOUND POWER RATING CPU 10.000 12950 17500 ESP IWG 1.5 1.5 1.3 SLOWPM RPM 750 940 800 BHP 7.5 12.8 20 OCTAVE IANO CENTERLINti FREQUENCY (Hz) 63 s0 93 05 125 88 01 92 sown POWEw tots 0.12WAr11 250 500 1000 85 88 1 88 I 83 85 80 89 89 84 2000 79 51 03 4000 74 77 78 8000 68 71 72 Sound Power Ratings for Supply Air Blowers in our Millenium Units with High Gas Heat, Economizer, 2: T/A Filters and Wet DX Sound power calculations complements of Lau's revised "Whirlwind" application selection software for alr moving com- nents. TABLE 57: OUTDOOR SOUND POWER RATING Wove Sand Centerline Frequer19Y (Mere:► 113 65 125 1 250 1 500 1 1000 J 2000 Sound Power Lev&, db (10) -12 Waltz L 4000 8000 53 83 98 17 ea 02 51 82 80 79 so 77 77 70 >3 74 75 71 72 73 89 70 71 MoDIL 112 i� 114 • *41C r NIT Memi _ NUeip/l 112 113 114 85 Note: These values have been accessed using a model of sound propagation from a point source into the hemi- spheric free field (AMCA 303 -79). The dBA values pro- vided are to be used for reference only. Calculation of dBA value s cover matters of sysem design, and the fan manufacturer has no way of knowing the details of each system. This consitutes an exception to any specification or guarantee requiring a dBA value or sound data in any other form than sound power level ratings. R .rut -t 4 db(A) 80 97 88 0 1398 1087 1487 dba 87 90 91 The sound ratings above occur at the blower wheel. To deter- mine the sound rating at a unit's supply and return air duct connection, subtract the attenuation factors listed below. Unitary Products Group Z 1 00 N0 W W F NW W LL Q u) d w O W 0 ON 0H WW u 0 z w 01- 0 Stun COIL 1 Doe 07 Mt. 1 87 IDr.. 17 Ib$, Wawa Moron (STD/ l,.in ) 7.5no 0/10 - - • ton. 10/20 0110 0/10 15NP 60/100 50/90 50/90 20141 105/110 95/100 66/110 25s1 - 155/200 155/200 WANT OUIDS VANU w/ . Acnuton 175 175 206 TABLE 54: UNIT CENTER OF GRAVITY "r MODEL ' TON TON 40 TON x r x 110/120 r x r eu.c Mir 99` 46" 45' 93' 49' OAtM Ul4r re Egon. 110' 1 ' 1 45' or 46' Pais Upir As ECON. S OAS oR ELECT. NEAT, STEAM OR Not WATEn MEAT 104' 45' 10 44" 95' I Disc UNIT /v/ BP ECaN. i Gramm DIMS. Met, & Porto Mauer 11 _ 45 11 44' 106" 1 45' 5,. 76/10 • 7,6N/ 100/110 . 100/110 1001110 10141 110/120 110/120 1101120 15N. 100/700 100200 4,3'eJ¼ Rev4&k TABLE 53: UNIT WEIGHTS COMPONENT Patio Uwei 235 MON 466 MOM 599 MOH 4OKW S0KW IOIKW MOr WATER COL 1 Row NOT WATER COI 2 Raw OA110MEnSC 1 6• RI010 ►tl CAPACTTv COIL COATED CONO. COIL NOT GAS Irma 25 TON 30 TON 4.300 4,000 OAS HIAT 90 90 1eo ELIC1 c NEAT 1 75 90 400 75 90 100 NOT WATER HEAT 71 90 97UM HEAT 40 Poem= 1 180 PA#MA CUM r 315 FULL CUM r 545 160 75 325 INMOST MOWN (Po/Ms Low A*W1? NEAR RWEN CONTROL 20919 O5V,410V & 31O- 3-55642 575V i 310.340 M2 1 10 10 40 4D Fame 60 RIMMOInaION 0 32 20 45 30 20 DISCONNECT 60 10 Cowv ue 10E Owner 1 40/40 j 40/40 40/40 Ammon 385 1 305 545 545 Weight Include/ 111e 10MP motor end economizer. Unitary Products Group 40 5,100 90 100 270 75 71 9* 90 tbs. 75 326 10 40 25 40 20 036 - 21091.002 Rev A (0001) 90 100 FIGURE 7 : CENTER OF GRAVITY • • 84 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP/UHP Flow Control Location of Service Location �� Cts, " M i CITE � D E BM F [Ip r L ill PE WIT f:PNTFP Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Total CFM OSA CFM Econo SEER or EER IPLV Location �� Cts, " M i CITE � D E BM F [Ip r L ill PE WIT f:PNTFP Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Total CFM OSA cfm Econo Input Btuh Output Btuh Efficiency` V L o v e- CITE � D E BM F [Ip r L ill PE WIT f:PNTFP Project Info Project Address f / 4 fJ_ -4 S Date 2 2 17 700 IN ? VALLEvf l-1 w 1 ept For Build g . Use --- FA I(W1t ->t WA- a1SQ Applicant Name: '(3o cry An kern} P r^ a rniance )- it A/C ,� lee.iiki Applicant Address: 44R 5, 'co Sf, I eel IJ' /► r g9o3 2 Applicant Phone: 45"_2S) — 03 S eo 2 1997 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. 1997 Was on State Nonresidential Ener. Code Com . Iir ^e Form Mechanical Summa' MECH -SUM FILE COPY First Edition -June 199B Compliance Option ,Simple System ❑ Complex System ❑ Systems Analysis (See Decision Flowchart (over) for qualifications) Equipment Schedules The following information Is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. '1f avallable. 2 As tested according to Table 14 -1, 14 -2 or 14-3. ' If required. ` COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 6 Flow control types: VAV, constant volume, or variable speed. M0a-031 System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? a Air cooled? ❑ Packaged sys? ❑ <54,000 Btuh 1,31 Economizer included? or 1900 cfm? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Mechanical Sum ary (back) ME CH -SUM 1997 Washington Skits Nonresidential Energy Cods Compliance Forms Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ,• 1997 hit)! ton State Nonresidentlat Ener! Code Coranliance Form <70% OA System Type or Cooling Only Includes Econo ? <54,000 Btu 1900 dm onstant olume r Cooled? Split stem? 84,000 Btu 2800 dm Sipple System Allowed Reference Sec. 1420 Use Complex System Heating Only no no eatirg/Cootng yes ackage yes stem no ( Reference Sec. 1423 yes no First Edition • June 1998 Reference Sec. 1430 'Complex Systems I Refer to MECH COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Proj 7 7 CO (..3Esr ✓ALLE L1 (' " ( I The following information Is necessary to check a mechanical permit application for compliance with the mechanical requirem en s in the Washington State Nonresidential Energy Code. AppNcability (circle) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS ctions 140 -1424) 1411 Eqpmt performance no n. a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 144 y no 61) 1411.1 Pkg. elec. htg. & clg. List heat pumps on schedule 1412 HVAC controls y.• gip 1412.1 Temperature zones indicate locations on plans yam no 1412.2 Deadband control Indicate 5 degree deadband minimum y no .a. 1412.3 Humidity control Indicate humidistat y no a.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types y no • a ✓1412.4.1 Dampers Indicate damper location and automatic controls y no a.a 1412.5 Heat pump control Indicate microprocessor on thermostat schedule y no q... 1412.6 Combustion htg. Indicate modulating or staged control y■ no 1412.7 Balancing indicate balancing features on plans y no :a 1422 Thermostat interlock Indicate thermostat interlock on plans •• n.a. 1423 Economizers Equipment schedule 1413 Air economizers no n.a. 1413.1 Operation Indicate 100% capability on schedule ya n.a. 1413.2 Control Indicate controls able to evaluate outside air no n.•. 1413.3 Integrated operation Indicate capability for partial cooling 1414 Ducting systems y 50 a. 1414.1 Duct sealing indicate sealing necessary yea no f:42 1414.2 Duct insulation Indicate R -value of insulation on duct y no 1415.1 Piping Insulation Indicate R -value of insulation on piping yes no a. 1424 Separate air sys. Indicate separate systems on plans lla Mech. Sum. Form Completed and attached. Equipment schedule with types, input/output, efficiency, ctm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440-1454) 1440 Service water Mg. yea ED a. 1441 Elec. water heater indicate R -10 insulation under tank yea no 1442 Shut -off controls Indicate automatic shut -off 1450 Heated pods y no 1452 (reserved) yea no 1453 Pool heater controls Indicate switch and 65 degree control y no 1454 Pool covers Indicate vapor retardant cover y no 1454 Pools 90+ degrees Indicate R -12 pool cover Nonresidential Energy 1997 We ' Compllence Forme on State Nonresidential Ener Mechanical Permit ns Checklist MECH -CHK 1997 Washington state Code • First Edition -June 1999 no is circled for any question, provide explanation: Code Com Ilanme Form 1997 V" - "hin r ton State Nonresidential Ener. Code Cr lance Form Electric Motors MECH -MOT 1997 Washington State Nonreeldentlel Energy Code Compliance Forms FlrM EdOlon • June 1990 Project Address Complete the following for all design A & B squirrel -cage, T frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location HP Type (open or closed) Minimum Nominal Full Load Efficienc Description of Application or Use Date For Building Department Use Synch. Speed For motors claiming an exception, list motor and note which exception applies. MIn.Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi-speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14-1 or 14-2) . 3. Motors that are an integral part (Le. not easily removed and replaced of specialized process equipment (Le. equipment which requires a special motor, such as an explosion -proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (Le. If the only U.L. listing for the equipment is with a Tess- efficient motor and there is no energy-efficient motor option). r,; .:m, J:;hk.k >. ,•:i - X , 040J•40eu,o4, vs,UJ& :444.d.i. J:2 ii+fiA�C. Open Motors - Closed Motors Synchronous Speed (RPM) 3,600 I 1,800 I 1,200 3,600 i 1,800 I 1,200 HP Efficiency ( %) Efficiency ( %) 1.0 - 82.5 80.0 75.5 82.5 80.0 1.5 82.5 84.0 84.0 82.5 84.0 85.5 2.0 84.0 84.0 85.5 84.0 84.0 86.5 3.0 84.0 86.5 86.5 85.5 87.5 87.5 5.0 85.5 87.5 87.5 87.5 87.5 87.5 7.5 87.5 88.5 88.5 88.5 89.5 89.5 10 88.5 89.5 90.2 89.5 89.5 89.5 15 89.5 91.0 90.2 90.2 91.0 90.2 20 90.2 91.0 91.0 9(12 91.0 90.2 25 91.0 91.7 91.7 91.0 92.4 91.7 30 91.0 92.4 92.4 91.0 92.4 91.7 40 91.7 93.0 93.0 91.7 93.0 93.0 50 92.4 93.0 93.0 92.4 93.0 93.0 60 93.0 93.6 93.6 93.0 93.6 93.6 75 93.0 94.1 936 930 94.1 93.6 100 93.0 94.1 94.1 93.6 94.5 94.1 125 93.6 94.5 94.1 94.5 94.5 94.1 150 936 95.0 94.5 94.5 95.0 95.0 200 94.5 _ 95.0 94.5 95.0 _ 95.0 95.0 1997 V" - "hin r ton State Nonresidential Ener. Code Cr lance Form Electric Motors MECH -MOT 1997 Washington State Nonreeldentlel Energy Code Compliance Forms FlrM EdOlon • June 1990 Project Address Complete the following for all design A & B squirrel -cage, T frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location HP Type (open or closed) Minimum Nominal Full Load Efficienc Description of Application or Use Date For Building Department Use Synch. Speed For motors claiming an exception, list motor and note which exception applies. MIn.Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi-speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14-1 or 14-2) . 3. Motors that are an integral part (Le. not easily removed and replaced of specialized process equipment (Le. equipment which requires a special motor, such as an explosion -proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (Le. If the only U.L. listing for the equipment is with a Tess- efficient motor and there is no energy-efficient motor option). r,; .:m, J:;hk.k >. ,•:i - X , 040J•40eu,o4, vs,UJ& :444.d.i. J:2 ii+fiA�C. P CAA ES 7 iVA 1. LE ti t '1 Date f� 2 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code, Use the checWist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Bui ing epartment Use Applicability I Code (circa) Section (Component Information Required Location on Plans Building Department Notes ADD NAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY y ■ /im J n.a. 1431.1 Field assem. sys. Provide calculations 1432 Controls y.. no C 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2 I emp. reset control y.. no n.a. 1432.2.1 Air systems indicate automatic reset no 1432.2.2 Hydronic systems Indicate automatic reset y.s no n.a. 1433 �~ Economizers indicate economizer on equipment schedule or provide calculations to justify exemption 1 I y .. no 1434 Separate air sys. Indicate separate systems on plans y.. no n.a. 1435 Simul. Mg. & dg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified yes no( n.a 1436 Heal recovery Indicate heat recovery on plans; complete and attach heat recovery calculations fray,) 1437 :200 Elec. motor etflc. MECH -MOT or Equip. Schedule with hp, rpm, efficiency R no e n.a. 1438 Variable flow sys. indicate variable flow on fan and pump schedules VII 1 no " is c(rcied for anv auestion. provide explanation: a 1997 Was Thton State Nonresidential Ener 1997 Washington State Nonresidential Energy Code Compliance Forms Code Com ►t •ce Form Mechanical - Comp - x Systems Checklist MECH -COMP First Edition • June 199E Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. Start Here Section 1411.1 Equipment Perf. Shall Meet Tables 14 -1 through 14 -: Capacity of Heating System Greater Than 600,000 Stub? F1eld- Assembled Equipmeat Air System Serving Multiple Zones Section 1432.2 Hot Wata apply Temperature Rae Controls Required Section 1432.2.: Supply Air Reset Controls Required 0 0 Section 1431.1 Calculations of Total On -site Ener Input & Output Required (continued on back) 43 .1.• la',... .n. ♦ -r. <_.. •:k:..,;r..�c:, ( .J 4 a4 �S ?:s' 4343. w: ,:al.Yb..:.reireagi >`..�.•'... •%'' Idbliti�. isi�7,' tC ,u ✓k i :�tvi FS'n �n'",v3�'•:,;,ti 1997 V,V in! ton State Nonresidential Ener. Code Co' - lance Form Mechanical - Co • Iex Systems (back) MECH -COMP 1997 Washington State Nonresidential Energy Code Compliance Forme FIN Edition • June 1999 See:tiaa 1411.4 Mud be Hat Pump Cool ing Capcity> 20.000 Btuh? Supply Air> 5000 am & Outside Air > 70 %? > 225,000 &uh Capacity? Fata a Pump >101-P? Section 1439 Venable Row Devi ms Required VAV Spam? oral Bldg Capacity > 240,000 & ah 1096 u tuts Nun -Scuie Secdoa 1433 Air-Side Eaaeum Required Sadao 1435 Flo Powered Tomball Units Required Stelae 1412.1 Modulating or Staged Cumtsrstlun Cumnds Required Swim 1435 Simukanaws Hating & Cuul ing Pruhibited Section 1437 Motors Must Meet Eficknues in Table 14-4 u u (continued from front) oat 0 n 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1620 206 623 0117 •tax 206 624 3115 www.coffman.com February 06, 2002 Mr. Mark Smeltzer PERFORMANCE HEATING & AIR CONDITIONING, INC. 7649 South 180 St. Kent, WA 98032 Project: United Rentals 17700 West Valley Hwy Tukwila, WA 98188 Subject: Lateral analysis of a new air conditioning roof top unit Dear Mark: Enclosed is our lateral analysis of the above unit. Our analysis is based upon unit dimensions and weight you have previously provided to us. The new unit weighs 7,608 pounds. This weight includes a 2,000 -pound curb adaptor. Our analysis shows that the following #12 self- tapping screws are required for seismic zone 3: 1. Connect the each side of the new unit to the curb with at least five (5) screws. 2. Connect the new curb to the existing curb with seven (7) screws along the short sides and twenty -three (23) screws along the long sides. Please call if you have any questions or concerns. Sincerely, LIW Marvin D. Emers. , .E. Structural Engineering MDE: 020381et020602 MDE M Smeltzer United Rental AC Unit Spokane, Washington 509 328 2994 Anchorage, Alaska 907 216 6664 a • 21 OFFMAN NG CIT YOF�TUKWILA PERMIT CENTER Structural Mechanical Electrical Civil Corrosion Program and Construction Management nnoa -oat Roof Top Air Conditioning Unit Replacement United Rentals 17700 West Valley Hwy Tukwila, Washington LATERAL ANALYSIS CALCULATIONS February 06, 2002 I 768 1 EXPIRES 4 21 l(i'✓ 1 Prepared by: COFFMAN NG1NEER 1601 Fifth Avenue, Suite 900 Westlake Center Office Tower Seattle, Washington 98101 (206) 623-0717 fa 4witz.ru-rzt: 1 ;ve.4,. 94 M Qt ,•4 r jJ, 1. Wood, ti (_ ) of) A C OFFMAN NGINEERS LAJ protect u i Ioctuon r/ Z ot 4Ua:) �e 7 by 144 sheet no. Job no (21 33 date©.2- 06- checked date client (JMo M ( r ( r--- } l � r ,a )(/ b4`0 7 ti X1,1.1 4: ° ei+ .N a G�-�" l.l'd -� '-PAc 14/4) C + ° t" — o 7 ' r A-a 1 CAT A'C - 1 r24::•,a; 11 U, U "c / 1 r "` ` 4,1 Nv 1l. y�C f.. : a ..... „vJ C7) ctrOwfr {`t�'4} h`et-�2 /„, c :*- �,,cr w t .. .. t i. °_ ;a t ` ! 0.•0 2 • 5• S.,tw- , ,t, ; t� 1 - 0 • Is” c is � ... I ^" l� 1 1444 r, .I:d2. c.v. a U '-11i „f � J +e+4wnsx+'uthw�lertrke'.xsrt..n +aisrnw�� r CVE ll a Tu k iJ i. 57.1.• p ia d " ( t (Trz COFFMAN project k) t { rEQ Re*rr location J KNJ t LTA , client , r �{'j'`" (j,�� Y', b 1 . 62-06-0Z —pZ checked date sheet no job no. ( - (V/o ) ( -) s F.•1 �� L f M ( 764 H o L .,0 6, � �� r� - 6 jI r X:71 r .rovet roc,:ti,$) c t \ ( P.? ,a, i l Of-4- CAU.AA.AA �" �1 ZOt 0,4,1;ii,r 5, v;;) Cht6Aryllevi,i„ Lri" c-A e. Nr 1 4-7. 4 S5 ) ` o L; (C. A COFFMAN < 1:s 17 S prolectl J V 4� 4/ 1�...�.7} i✓ jest 1 t...l�, / "1L ..�.t location �` JJ t L :' `, VV IL client FR AC" T.4.4 a, 1 si 1L 6: 12 c .L s 23 by Checked dale c shoal no L&T, G ' job no. n 7 , r• f .1b �_a.::l:i.�crti.'+.r: n.A•� i.�la ..�:��.....t fir_.. • Screw Size Section Gouge No. 12 (d= 0.209 ") No. 10 (d= 0.183 ") No. 8 (d= 0.161 ") No. 6 (d= 0.135 ") Shear Pullout Shear Pullout Shear Pullout Shear Pullout 25 74 50 69 44 65 39 60 32 20 185 92 173 81 163 71 149 60 18 276 120 258 105 242 93 222 78 16 387 151 363 132 341 116 N/A N/A 14 548 190 513 166 N/A N/A N/A N/A Min. Edge Dist. And 11/16" 9/16" 1/2" 1/2" 0.C. Spacing ONINN 1 Itus BUGLE HEAD - SELF DRILLING For drywall attachment to metal studs and joists. Also used for attaching cabinets through gypsum board and insulation board. Metal thickness — 20, 18 16 and 14 gouge. BUGLE HEAD For drywall attachment to metal studs and joists. Also used for attaching cabinets through gypsum board and insulation board. Metal thickness — 25 and 20 gouge. WAFER HEAD - SELF DRILLING For metal to metal framing connections when drywall, plywood and other similar wall materials are used on metal studs and joists. Metal thickness — 20, 18, 16 and 14 gauge. WAFER HEAD For metal to metal framing connections when drywall, plywood and other similar wall materiels are used on metal studs and joists. Metal thickness • 25 and 20 gouge. HEX HEAD - SELF DRILLING For attaching steel deck, backup plates, door frames, lathers channel to metal framing and structural connections. Metal thickness — 20, 18, 16 and 14 gouge. PAN HEAD - SELF DRILLING For attaching steel deck, backup plates, door frames, lathers channel to metal framing and structural connections. Metal thickness — 18, 16 and 14 gauge. Notes: 1. All values based on connected parts having a minimum yield stress, Fy =33 ksi and a minimum ultimate stress, Fu =45 ksi. 2. When connecting materials of different gauge thickness, use loads shown for the lighter gauge. 3. Applied shear loads may be multiplied by 0.75 for wind or earthquake loads per AISI A4.4. 4. For screws in tension, the head of the screw, or washer if provided, shall hove a minimum diameter of 5/16 inch. —53— QUANTITY: UNITS DESIGNATION: ScMdWe No: Model No; Y14AN44M$KAG88 [> RETURN AIR SUPPLY AIR 1.1? FPT &0.33' 4s DETAIL 71 .61" �► _ � � N A 6.48" 5.er 147F!'FPT FLAMED 4.516* FTTTLNO I BASE RAIL 7859"215` oar c_ 341115 BA C BASE RAIL 1.104•FPT DETAIL B (ELECTRICAL CONNECTION) 100.10" FOR COOLING ONLY AND ALL HEATING APPLICATIONS 1- 14'FP7 FRONT 31116 Nate Hole mud be 1i1.ct It Anti, DETAIL C (GAS CONNECTION, THROUGH CURB) IIYORIC Sr Motto Gee Cb Arabie" Profsct Dame 40 ton VAV MILLENNIUM AtahMect Engineer Purchaser ' PERFORMANCE HEATING Sub mItted By FAMILIAN HVAC JAN -31 -2002 15:32 i-r col p.2 MILLENNIUM Date 12/17/2001 Page 2 VARIABLE VOLUME UNIT NRTM FACTORY INSTALLED VFD AND OAS Order No 1111001 v3,r Minh soot f wt.a M change wee* men • Oh.a, MCnr coin 425 251 02E10 95% P.02 QTY. "BASE" DIM. '1' I. 4 ik 4 f 90 -3/4" x 248" 83" x 231" l' pajp(nsu! Suj J / ,s' ,4 . .!' _______ - RETURN U r L .8/E=BL 14" 69 - 3/8" II '34 -1/4" _ • 103 -1/8" ' QTY. "BASE" DIM. "TOP" INSIDE DIM. "TOP" OUTSIDE DIM. : A . f 90 -3/4" x 248" 83" x 231" 86" x 234" _______ - RETURN U SUPPLY 14" 69 - 3/8" II '34 -1/4" I • 103 -1/8" ' •' 5 -1 /E 2 -18' 248" SASE QTY. "BASE" DIM. "TOP" INSIDE DIM. "TOP" OUTSIDE DIM. TAG 90 -3/4" x 248" 83" x 231" 86" x 234" New York Y13/14 Millennium Old Trane SARA- 400/500 �. •� • u L u.7 • JJ�+ ROOF PRODUCTS INC 7616 LEE HIGHWAY CHATTANOOGA, TN 37421 1- 800 -262 -6669 F.423-892-2107 STANDARD FEATURES 1. 14 (is. Prime Ostvenized Steel Construction 2. Fully Welded Watertight One•pieee Consuuction 3. Primed Pointed after Fabrication 4, 1" Thick Neoprene Faced Fibergletslniulation 5. Closure Angles 6. Lund Distributing Interval Reintoreement (As Required) 7, Duct Supports & Oeaketirtg (when Required) b. Sloped Extensions to Eliminate Standing Water A4tT lxtci 1-oOo Cu2'& JAN -31 -2002 15 :32 rer•r ur'meiriee neat i ng l 405) 251-0280 OPTIONS; 1. 2. 3. 4, 234" Outside Top Dimension 231" Inside Top Dimension 103 -5/8" 1,1/2 "' 1-1'/2" 1'-112" I 28- 9/16" I 26" + I ' 71.5/16" Page Of ❑ APPROVED BY: DATE APPROVED: PROJECT NAME: CITY, STATE: CUSTOMER: JOB NUMBER: '244 .. " NSW cute z000 � S O u M', eG'U L. CogMg- 425 251 0280 96% P,05 -- .�..,�,.,.,,�»..�•.�..+., -.,�,. �xrr�s�^ ^�""�'_._.sa9�tl+e' �'�+e' n�rvn+rn�Y P - 5 1 1 1 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1620 206 623 0111 • fax 206 624 3115 www.coffman.com February 6, 2002 Project: United Rentals 17700 West Valley Hwy Tukwila, WA 98188 Dear Mark: Please call if you have any questions. Sincerely, / i ! �r Marvin D. Emerson, S.E. Structural Engineering MDE: Ikb 020381et020602 MDE M Smeltzer United Rentals Spokane, Washington S09 328 2994 Anchorage, Alaska 907 276 6664 Mr. Mark Smeltzer PERFORMANCE HEATING & AIR CONDITIONING, INC. 7649 South 180 St. Kent, WA 98032 Subject: Structural review of existing framing a new Air Conditioning replacement unit AEOFFMAN We have reviewed the existing roof framing of the above building. Our analysis is based upon existing framing information provided by your firm. The framing consists of 3' /z" x 13 purlins spaced at 8' o.c., spanning about 18' -0 ". These purlins are supported by a 5" x 15 '/2" glu- laminated beam over 6" sq. steel columns. You have provided the unit weight as being 5608 pounds. With the curb weight of 2000 pounds, the total load is 7608 pounds. A bearing wall supports one side of this unit. Our analysis shows that the existing wall studs, purlins and beams are capable of supporting this unit and will not need any additional reinforcement. CIT RECEIVED PERMIT CENTER l EXPIRES 4 21 1 Structural Mechanical Electrical Civil Corrosion Program and Construction Management MO. Roof Top Air Conditioning Unit Replacement United Rentals 17700 West Valley Hwy Tukwila, Washington STRUCTURAL REVIEW OF EXISTING ROOF FRAMING February 06, 2002 Prepared by: ACOFFMAN NGINEERS 1601 Fifth Avenue, Suite 900 Westlake Center Office Tower Seattle, Washington 98101 (206) 623.0717 • 1 '71 kJ ) c?.:1 - 0- L.A 4- ! ..! • v. . - ,-.- a f .) ••••.- i;„ !.. t. ' ....t -, ...., L 7 1 t 11 !,1 c.f.-/sA ,17 I. • af ( Tkt e, e..,L1 A !!!! / 4 0.. t I! t. ! at tk(;)( 164f) 1. r . a I , • t% ' •f " OFFMAN AIENGINEERS wood U kJ I I I --- 0 ,/ • r t.i-- - '.‘ ."' ' ' . ,. ' i.... . - by .4 . ,,,,./::.....t. sheet no- ...a / 7 1 "I • f diem 1 1 .,,, ! 1. )::,,,- , checked job no. date • 1 '71 kJ ) c?.:1 - 0- L.A 4- ! ..! • v. . - ,-.- a f .) ••••.- i;„ !.. t. ' ....t -, ...., L 7 1 t 11 !,1 c.f.-/sA ,17 I. • af ( Tkt e, e..,L1 A !!!! / 4 0.. t I! t. ! at tk(;)( 164f) 1. r . a I , • t% ' •f " • • e et kit *)';' r•t• I • . I w, kor. p (,7 4 e e.. ? 7/2-1 1 a ( ' 1 v"" 1 .4 C • + ) • 4.1) F - 7.5 I Y";' e U 1 2 .1.,4 : ( • L OFFMAN AFNG1NEER S 1 i 1 "".. - - , project • I • ; , . ' •''' ,.. i.- \ .1" 1 i ,..... " ..... . ,,,,,, by , .(tf. sheet no. -. .. , C........ ,..... ,, i ' --4 Irt ) AI !. location 1 •••••• "' ''' '' L. 1 -.. •,• • '' '',' * . ' ,„..,.1,i•-. client ■:-.. / . ' .'-, s ' . • “i4 • I, 1 . cheched job no. .,.., . .. . date • • e et kit *)';' r•t• I • . I w, kor. p (,7 4 e e.. ? 7/2-1 1 a ( ' 1 v"" 1 .4 C • + ) • 4.1) F - 7.5 I Y";' e U 1 2 .1.,4 : ( • L 5x15 -I/2 GLt- STEEL SADDLE TYPICAL 6x6 STEEL COLUMN - 5 /565' - 5x22 -1/2 GLB 3 -1/2 "x13" WOOD PURLIN @48" O.G. STEEL SADDLE TYPICAL 6x6 STEEL COLUMN 5x21 GLB CA) D B 3- I /2 "x13" WOOD PUF S' - O" O.G. TYPICAL EXTERIOR BEARING W/ STUDS @ 16" O.G. CORNER WEIGHT, TYP. EXISTING ROOF CURB 1 AS BASE FOR NEW GUP REPLACE EXISTING VA\ SET RTU -I ON EXISTING CURB ADAPTER EXISTING 3 -1 /2 "x13" GRC 54540' -0" ■ ti IL \i r ' , r t..1 ),;6 lla� IIYORIC no Tbee.to Get CbmkrtUle• Prefect Name 40 ton VAV'MILLENNIUM Archltect Engineer Puroheaer PERFORMANCE HEATING Submitted By FAMILIAN HVAC QUANTITY: UNITS DESIGNATION: Schedule No: RETURN AIR ilk SUPPLY MR 1,616" FP T FLANGE D iSle" / F1TTINO I BASE RAIL 1 - 1/r FP T (DRAIN CONNECTION) JAN -31 -2002 15:32 MILLENNIUM Date 12/17/2001 Page 2 VAR IAILE VOLUME UNIT 1MT1 FACTORY INSTALLED VFD AND OAS Aber No f BASE RAIL 1104'FPT 425 251 0280 3:1!1'6' 6.4r Ut U ,IL 6 (ELECTRICAL CONNECTION) FOR COOLING ONLY AND ALL HEATING APPLICATIONS 1141PI001 YI.I Minh MI 440401. duns lothowl more • Chace IocsI codas Model No; Y14AN44M$KAGBB 95% 34/16" FRONT Note Hole must be debar/ R lob ssle. DETAIL C (GAS CONNECTION, THROUGH CURB) P.02 / • sCakCtxC '!s7 . ztr?si4":0 3.i'S3V MODEL. TON TON • 40 TON r Y X r x Y, x -• MC ► IT 99 ' ' - 45 93 4 - 8A3ic UNIT Na Ecow. 11Q ,. •,. I : 9 ,• B•9ic UNIT tw EooN. & OAS OR ELECT. HEAT, STEAM on MOT WATER NEAT 10C 45 10 -4 • : ' UNIT 1W ECON. & � .1 i . MEAT, ac P0WER EYHAusr 11 45 11 108" 45' _ • y ,100 90 180 Z70 75 ON 90 to FIGURE T : CENTER OF GRAVITY I lbs 1 tbs. ' tbs, V1101 5/200 !OS 7S N110 V120 JAN -31 -2002 15:32 MISR br a1►1017r 036- 21091.002 Rev A (080 1) c TABLE 54: UNIT CENTER OF GRAVITY 4 ' 425 251 0280 95% • LIP UK I i coN \v y 80WVO pwFw 0- ATTS OCTAVE BAND CENTtRLINE FREQUENCY (Hz) 125 88 91 250 es 88 500 85 88 • 1000 T 2000 80 83 78 81 4000 8000 74 68 77 71 vv � v dba 87 90 le sound ratings above occur at the blower wheal. To deter - ine the sound rating at a unit's supply and return air duct tnnAction_ subtract the attenuation factors listed below. JAN -31 -2002 15:32 425 251 0280 95% P.04 fl 3 0 TON 40 TON c _ o A _ 8 C D _, ; 7 � 118% . 30 94 1220 : t 153 3 i ' : 1398 1 • 1259 1310 1 203 1 1 73 1437 467 16 1348 1347 1317 14557 1487 1 LIP UK I i coN \v y 80WVO pwFw 0- ATTS OCTAVE BAND CENTtRLINE FREQUENCY (Hz) 125 88 91 250 es 88 500 85 88 • 1000 T 2000 80 83 78 81 4000 8000 74 68 77 71 vv � v dba 87 90 le sound ratings above occur at the blower wheal. To deter - ine the sound rating at a unit's supply and return air duct tnnAction_ subtract the attenuation factors listed below. JAN -31 -2002 15:32 425 251 0280 95% P.04 fl QTY. "BASE" DIM. "TOP" INSIDE DIM. "TOP" OUTSIDE DIM. 4 1111' . uodo u8 /E`8L 7 / 7, Aa • Slgpfg In suje(ed 86" x 234" New York YI3 /14 Millennium Old Trane SAFTA- 400 /500 -.I QTY. "BASE" DIM. "TOP" INSIDE DIM. "TOP" OUTSIDE DIM. TAG 90.3/4" x 248" 83" x 231" 86" x 234" New York YI3 /14 Millennium Old Trane SAFTA- 400 /500 ROOF PRODUCTS INC - 7616 LEE HIGHWAY CHATTANOOGA, TN 37421 1- 800 -262 -6669 F.423- 892 -2107 STANDARD FEATURES. 1. 14 fia. Prime Oel"enized Steel Conetructlon 2. Fully Welded Watertight One•plece Construction 3. Primed fainted after Fabrication 4. 1" Thick Neoprene Faced Fiberg ats Insulation 5. Closure Angles 6. Load Distributing internal Reinforcement (AS Required) 7. Duct Supports it Ougketittg (when Required) B. Sloped Extensions to Eliminate Standing Water OPTIONS; 1. 2. 3. 4. 234" Outside Top Dimension 231" Inside Top Dimension 1 - 1/2" 1 -1/2" 1-1/2" 103-5/8" 1 28-9/16" 1 26" 71-5/16" 41" RETURN �` SUPPLY L . 14" 69-3/8" Acc5T r+��i 34.1/4" 248" BASE 103 -1/8" Page Of JAN -31 -2002 15:32 425 251 0280 5 -1/8" 112 -1/8'I ❑ APPROVED BY: DATE APPROVED: PROJECT NAME: CITY, STATE: CUSTOMER: JOB NUMBER: O E 0 U m O .0 H 311 Nsw cu.v z000 IBS, 15U M. eaV ?L vJS(6HTS 96> P.05 July 3, 2002 Mr. Barry Anderson 7649 S 180 St Kent, WA 98032 Dear Permit Holder: City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Application No. MO2 -031 Location: United Rentals 17700 West Valley Hy In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Cali the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress or a final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to August 18, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Kathryn A. Stetson Permit Technician Xc: Permit File No.MO2 -031 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206-431-3665 DEPAR MENTS: Buildin i ision Public Works \PRROUTE.DOC 5/99 APPROVALS OR CORRECTIONS: (4 weeks) 1 112 Fire Prevention [dr v 2 •!, Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete If Incomplete n TUES /THURS ROUTING: Please Route Y Structural Review Required n REVIEWER'S INITIALS: Approved Approved with Conditions) REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved ri Approved with Conditions REVIEWER'S INITIALS: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP PERMIT COORD COPY DATE: 02 -07 -02 ACTIVITY NUMBER: MO2 -031 PROJECT NAME: United Rentals SITE ADDRESS: 17700 West Valley Hy SUITE # 1k Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Planning Division Permit Coordinator DUE DATE: 02-12-02 Not Applicable Comments: No further Review Required DATE: DUE DATE 03 -12 -02 Not Approved (attach comments) ri DATE: DUE DATE Not Approved (attach comments) n DATE: ACTIVITY NUMBER: MO2 -031 DATE: 02 -07 -02 PROJECT .NAME: ' United Rentals SITE :ADDRESS: 17700 West Valley Hy SUITE # •Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Complete U'RROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP Fire Prevention n Planning Division Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Approved ri Approved wit Conditions REVIEWER'S INITIALS: 1� 11 Permit Coordinator n DUE DATE: 02-12-02 Not Applicable Comments: TUES /THURS ROUTING: Please Route n Structural Review Required ri No further Review Require REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (4 weeks) DUE DATE 03 -12 -02 Not Approved (attac comments) DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions I I Not Approved (attach comments) REVIEWER'S INITIALS: DATE: PERMIT NO.: MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 1 Pre - construction ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ Chimney Installation/All Types 700 Framing ] 1080 Woodstove 1090 Smoke Detector Shut Off 1100 Rough -in Mechanical ❑ 1101 Mechanical Equipment/Controls 1102 Mechanical Pip /Duct Insul 1105 Underground Mech Rough -in 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final ❑ 4015 Special -Smoke Control System CONDITIONS 10001 No changes to plans unless approved by Bldg Div ❑ 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & 1 10005 All permits, insp records & approved plans available 10014 Readily accessible access to roof mounted equipment 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 1004 Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: OkII4 !� FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended /Wall /Floor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig /Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) Plan Reviewer: Permit Tech: Date: Date: over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfrn (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'I Fees — Work w/o Permit (Y/N) lnsp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) 4 V0 co co al • u_ W O 2 g Q til U 0 I- W W, H H • O , Z rn Z PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -031 DATE: 02 -07 -02 PROJECT. NAME: United Rentals SITE ADDRESS: 17700 West Valley Hy SUITE # Original Plan Submittal Response to Incomplete Letter # Response.to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Complete n Comments: \PRROUTE.DOC 5/99 n APPROVALS OR CORRECTIONS: (4 weeks) Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES /THURS ROUTING: Please Route n Structural Review Required Approved Approved with Conditions REVIEWER'S INITIALS: /i # 57. z Planning Division Permit Coordinator DUE DATE: 02-1 2-02 Not Applicable No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE 03 -12 -02 Not Approved (attach comments) n n n DATE: — / ? — 0.e:2 CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: v 0 U 111111111•1111111. F625-052-000 (8/97) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST.. #- EXR.-TATE'' CCO1 PERFOHA15ORT 04/28/2002 EFFECTIVE DATE . 12/30/1985 PERFORMANCE HEATING & A/C INC 7649 S 180TH KENT WA 98032 1 N-) NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. HVAC EQUIPMENT SCHEDULE TAG MFR DESCRIPTION MODEL NOM. TONS INDOOR FAN EXHAUST FAN EER IPLV ELECTRICAL SOUND (BELS). WEIGHT (LBS.) REMARKS CFM. SP HP HP TYPE VOLTS PH.. MCA MOCP RTU -1 YORK PACKAGE ROOFTOP VAV UNIT Y14ACO4M8KAGBE 40 16,000 25 15 0-100% MOD 9.5 9.7 460 30 146 175 8.8 5608 W/ ECONOMIZER & SMOKE DETECTOR NOTE: THESE PROPOSALS, PLANS, SPECIFICATIONS & QUOTES ARE THE SOLE PROPERTY OF PERFORMANCE HEATING & AIR CONDITIONING, INC. (PHAC) AND ARE FOR THE SOLE, CONFIDENTIAL USE OF PHAC AND THE INDIVIDUAL TO WHICH THESE PLANS ARE DELIVERED. ANY DISSEMINATION OF SUCH MATERIALS OR PORTIONS THEREOF TO AN ADDITIONAL INDIVIDUAL OR COMPANY WITHOUT THE PRIOR WRITTEN PERMISSION OF PHAC IS STRICTLY PROHIBITED AND SHALL ENTITLE PHAC TO REASONABLE COMPENSATION FOR THE PREPARATION OF SUCH MATERIALS, TOGETHER WITH ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM SUCH MISAPPROPRIATION. ALL DRAWINGS AND SPECIFICATIONS ARE PRELIMINARY ONLY AND ARE SUBJECT TO CORRECTION, AMENDMENT AND SUPPLEMENTATION BEFORE COMMENCEMENT OF WORK. *5' -0" 5x15 -I/2 GLB STEEL SADDLE TYPICAL bxb STEEL COLUMN 5x22 -I/2 GLB 3 -1/2 "x13" HOOD PURLIN ®48" O.G. STEEL SADDLE TYPICAL bxb STEEL COLUMN TAX ASSESSOR'S PARCEL NUMBER: 3623049057 LEGAL DESCRIPTION: LOT 2 OF RENTON SHORT PLAT NO346 -79 REC NO 7907169001 SD PLATDAF - POR GL 2 & NE 1/4 OF NW 1/4 SD SEC LY ELY OF WEST VALLEY ROAD& WLY OF PSE RAN & LY NLY OF LNWCH IS 756 FT N OF MEAS AT R/ATHOF & PLT N LN OF S 180 TH ST LESS POR CONY FOR SR 181 SCOPE OF WORK: REPLACE EXISTING ROOFTOP VAV COOLING UNIT WITH NEW UNIT OF EQUAL CAPACITY. 5x21 GLB PARTIAL ROOF PLAN / FRAMING PLAN SCALE: 1/8" =1' -0" z ---3-1/2"x13" WOOD PURLINS - 8'-O" O.G. TYPICAL EXTERIOR BEARING HALL - 2X6 WOOD STUDS ® Ib° O.G. CORNER HEIGHT, TYP. 7 —EXISTING ROOF CURB TO REMAIN AS BASE FOR NEW CURB ADAPTER REPLACE EXISTING VAV UNIT HITH NEW RTLI -I SET RTU -I ON EXISTING CURB USING NEW ROOF CURB ADAPTER EXISTING 3 -I/2 "x13" GROSSBRACING RTU-I +4 -0" PARTIAL SOUTH ELEVATION SCALE: 1/8" =1' -0" i Ib5' -0" SITE/KEY PLAN SCALE: 1132" = 1' -0" RTU-I ,LE COP 1 uTde stand that the Plan Check approvals are subject to errors and omissions and approval of plans does, not authorize the violation of any adopted code or ordinance. Receipt of con- tractors copy of approved pans acknowledged. By _ �(lUl Date M � -0 � Permit No. 1 ` 0 i - O 2 t SEPARATE PERMIT REQUIRED FOR: 0 €iECYAW!CAL ['ELECTRICAL E UI -.113ING I f CAS PIPING CITY OF TUKWILA BUILDING DIVISION Mom 031 DATE c 1/28/02 DRAWN: MS /BA ENGR: MS /BA APPYD: JOB NUMBER: 4332Q M I SHEET 1 OF 1