HomeMy WebLinkAboutPermit M02-036 - LOWER JUNCTION - LOT 5LOWER JUNCTION
LOT 5
5428 S 150 ST
M02 -036
City of ijukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 8733000060
Address: 5428 S 150 ST TUKW
Suite No:
Tenant:
Name: LOWER JUNCTION - LOT 5
Address: 5428 S 150 ST, TUKWILA WA
Owner:
Name: SCHERLER ARNOLD E
Address: 5439 S 150TH ST, TUKWILA WA
Contact Person:
Name: DON TRYON
Address: 14420 SE 84 ST, NEWCASTLE, WA
Contractor:
Name: TRYON CONCEPTS LLC
Address: PO BOX 146, RENTON, WA
Contractor License No: TRYONCL013DH
DESCRIPTION OF WORK:
INSTALL NEW FURNACE AND WATER HEATER INTO NEW SINGLE FAMILY RESIDENCE
Value of Construction:
Type of Fire Protection:
Permit Center Authorized Signature:
Signature:
doc: Mech
$4,000.00
N/A
MECHANICAL PERMIT
-i%'e
Permit Number: MO2 -036
Issue Date: 01/06/2003
Permit Expires On: 07/05/2003
Phone:
Phone: 425 255 -6518
Phone: 425 - 255 -6518
Expiration Date: 02/11/2003
Fees Collected:
Uniform Mechnical Code Edition:
Date: " z23
$70.25
1997
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit.
Date: /-6 3
Print Name: 2di✓ 1i2 (Feb A..)
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
MO2 -036 Printed: 01 -06 -2003
I
0
doc: Conditions
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 8733000060
Address: 5428 S 150 ST TUKW
Suite No:
Tenant: LOWER JUNCTION - LOT 5
PERMIT CONDITIONS
Permit Number: MO2 -036
Status: ISSUED
Applied Date: 02/20/2002
Issue Date: 01/06/2003
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be
inspected by that agency, including all gas piping (296- 4722).
4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
work will be inspected by that agency (206- 835 - 1111).
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear
identification showing the fire performance rating thereof.
7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
9: Manufacturers installation instructions required on site for the building inspectors review.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature: .CDP°7 G Date: / (p -c) 3
Print Name: AA) 772vo .)
MO2 -036
Printed: 01 -06 -2003
Project Name /Tenant: �..
LUGJE'!Z �UNCT� O 4) C01 S
Value of chanical Equipment:
of
Site Address :
City State /Zip:
S. /SC) 14 S/ —7-(-11r4431 (6 cJw 9.',.X '
Tax Parsel Number:
' 3 - 4246 a
Property Own
.Ko
Sc4.er /e f-
!4) 6, _ 1
Phon ( )
206 24 -e6(?
Street Address:
5
, Stat Zip:
S. /5c) -71 75 Kw 14 Fil 12
Fax #: ( )
Contractor:
PA 5
,4 Ti�6
PP5 M"�4)(33 DA
Phone: S ) ( F es . ..07e 7
9
Street Address: �i City Stat Zip:
/20 2 2 7 ?lee Ne kl,A -k ed Qpo3
Fax #: ((15) DZ
o S -e «
Contact Person: . .__.-
A) (( � ;,)
Ph one: y 255 as47
Street Address:
/44242 S 'E 4.4 5,
City St e/Zip:
4 6 () 9 k s 7
Fax 11 ?.,r )
25 5. _ F6 Z
BUILDING !OWNERORAUTHORIZEDAGENT::
Signature: ...—,--N
�
Date: 2 --2a r0 Z
Print nam e:D
!4) 6, _ 1
Phone: 4115 ) .2ss.4s l"•
Fax II: (!{E5 )
94771
Address: /44(
St- .kw ..4
',i"
City /State/Zipkk //Q 624 p0o
11/2/99
Hier. pennit,due
CITY OFT1►WILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
STAFF t)SE ONLY
Project Number:
Permit Number.
1'►'102 •03(i
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
MECHANICAL; PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT)
Description of work to be done 14 b / e�peci 'c): I" /& 4
T G � !�t C re et K a
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LA WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application accepted:
,,?d2
Date application expires:
?NW I-0 a
Application taken by: (initials)
&CP
✓
Submittal Requirements
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening
Heat Loss Calculations or Washington State Energy Code Form #H -7
H.V.A.C, over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for new and the replacement of existing roof equipment
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer.
•
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
11/2/99
m!acpmr.duc
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
RESIDENTIAL: Two complete sets of attachments required with application submittal
Submittal Requirements
New Single Family Residence
Heat loss calculations or Form H -6.
Equipment specifications.
Change - out or replacement of existing mechanical equipment
I Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition.
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
Ire ,tel
11 tr WO fill!
RECEIPT
w W
Parcel No.: 8733000060 Permit Number: MO2 -036 • ? . §.
Address: 5428 S 150 ST TUKW Status: APPROVED N
Suite No: Applied Date: 02/20/2002 ( _.
Applicant: LOWER JUNCTION - LOT 5 Issue Date:
N LL;
W o
Receipt No.: R03 -00010 Payment Amount: 70.25 2
g J ,
Initials: SKS Payment Date: 01/06/2003 11:53 AM u - D ;
User ID: 1165 Balance: $0.00 = fy
Z ,
Payee: TYRON CONCEPTS, LLC. P-;
M 0
co
TRANSACTION LIST: 0 N;
Type Method Description Di-
Payment Check 2863 70.25 Q',
• w Z
V N
O
Z
ACCOUNT ITEM LIST:
doc: Receipt
City of Tukwila
Current Pmts
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Amount
MECHANICAL - RES
PLAN CHECK - RES
Description Account Code
000/322.100
000/345.830
56.20
14.05
Total: 70.25
,4 ill. 01/07 9716 TOTAL 5051.50
Printed: 01 -06 -2003
•
Project: +
J liiv.ch 0 v'
isl
S
Type of Inspection: 1
-S,V�
Address:
S L1 ;$
S ,
1 50 S+
Date Called:
- 1 - ‘,2 -
Special Instructions:
Date Wanted:
a 1 .
Requester:
V\
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Moz -o3fol
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
$r 0A Cov►" ?
01L
Inspector:
Date: - 0 3
El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
(Receipt No.:
(Date:
122:i'V;4•41' in;i2ii j,��ri:;3Ar97;7 ir4+ ?;t2,:�.%s3.`WA
Z
I
W
�U
U
co
co w
co IL
w 0
u_ a
co d
I— O
z �.
D
O N
O 1—
W uj
iil! 52
Z
P oJeect:.
I I Y J onC - ho i -Lo
Type spection•
L — A v
Address
5 R -S /50 37
Date Called:
' ,?
f� ,
Special Instructions:
Date Wanted 03
Requester:
Phone o
kiN- ;4;': >;::;e:'�'.:'.ti �,. +..Si Zvi +• x [ ti,:i',t;',n��:.)
Approved'per applicable codes.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Corrections required prior to approval.
COMMENTS:
V
7.00 REINSPECTION FE REQUIRED. Prio to inspection, fee must be
paid at 6300 Southcenter B d., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
Z
rew
00
cow
co
� 0
w 0
ga
u.
Z
z°
LU Ili
U�
ON
0 I—
W W
g
LLO
Z
Ui
0
z
N.
Project Name: y< < , ,,�,0 i
Lo 70N c 77o�c) LD'7 5 `'-� �``�
Address:
5/1 S. 1` Si
Residential Building Permit Number: 45
1. Prescriptive Option W.S.E.C. Chapter 6, (check building permit option used):
CI I. CI ii ❑III. CI iv. f CI vi. ❑VII. CI VIII.
2. House Square Footage (HSqFt)
Z36/
3. Heating System installed, (check system type below):
El a. CITY a. Electric Resistance /21 BTU /h s . ft. RECEIVED
P sq. OF TUKWILA
❑ b. Electric (forced air) /24 BTU /h per sq. ft. FEB 2 0 2002
® c. Other Fuels (gas, heat pump) /27 BTU /h per sq. ft. PERMIT CENTER
4. Equipment:
a. Make le lA
b. Model gt4 K 675
c. Size in BTU's (oo oo
5. Calculation /(HSqFt) 23C•( (see line 2 above)
BTU /h X 2 7 (see line 3 a, b, or c above)
63 - 741 BTU Equipment Maximum Size
PERMIT APPLICATION #: M V ' o o
7/9/96
CITY Ot- TUKWILA
Permit Center
6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188
Telephone: (206) 431 -3670
FEU {i _ OERS COPY
Prescriptive Heating System Sizing for
Single Family Homes - New Construction
Washington State Energy Code Chapter 9, Clin t o +ne'1ttk
p 'PRO'1E 0
DEC 2 3 ?002
TW !iJILiJ
H -6
Applicant's Signature:
l/Ly0' .
Date:
Z' —o Z
Moe- o�
t — Ca4-S u
P.P. & S. Heating & A/C Inc.
12022 98th Ave. NE
Kirkland, WA 98034
ref:45 A 6,45 re.Razto ,A-a& ,Mln)G,
0.41) , c'og s cr a gook_ .
-WE sz,v u,J iT
in+4 / SI :
(Z,~ 507. UPS 1.h- — 1 9 FYN pc.%TPuT"
1-{P Wi so sA(.. Gays Lomat& itir.gcrsk
1�U og unlnrs;
CITY OF TUKWILA
APPROVE!)
DEC 2 3 2002
t ar JZ , f •V /� a 1
Moe •ow
RHEEMGLAS Fury Plus
High Performance, Energy Miser®
rmosavew.e... Gas Water Heater
CITY OF Ti;vA;LA
Available in 40 and 50 gallon tall -
30 and 40 gallon lowboy models DEC 23 2c
• 5-Year Limited Tank Warranty*
• 1-Year Limited Parts Warranty*
• High performance and recovery
• Patented R-Foam® insulation process for FEB 2 0 2002
superior heat retention
• Gasmaster burner with precision port PERMII t 'Ef‘J ER
alignment for even heat transfer
• Heat saving flue baffle design
• Compliant with many gas utility incentive programs**
• Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirements
• See Residential Warranty Inlormation Brochure for complete warranty Information
- 40.000 BTU models only.
SPECIFICATIONS
Gas Input First Hour
T ; Tank in 111°i/sands Recovery In oeuyely ;
EliiLnEPS COPY
Roughing in Dimensions
Y Model Ca BTU/Hr. G.P.H. Rating 'Enlit0Y (Shown in Inches)
' p. L____________ '
P Numhert GaN. 90 Rise G.P.H. Factor ; Wght..
'
E LP Lbs.
Nal. 'Burner Nat. LP Nat. LP ABCD, EF CH
41VR40 40 40 40 40 4 40 4 68 68 0.62 127 61% 581/2 21 8 3 131/2 2 1/2
41VR40N 40 375 — 40 4 — 68 — 0.62 127 61 581/2 21 8 3 131/2 2 1/2
A
L 41VR50 ; 50 40 40 40.4 40.4 74 74 I 0.62 151 60 571/2 • 23 8 ' 3 ' 131/2 2 1 /2
41VR50N• 50 40 — 404 — 74 — 0 62 151 60Y, 571/2 23 8 3 131/2 2 1/2
411P0S 30 34 34 344 344 54 54 0.58 109 501/2 461/2 17 8 3 131/2 2
411/40S 40 37 37 374 37 4 65 65 0.56 138 521/2 481/2 19 8 3 131/2 2 1/2
. _ . . .
BOY -
41V50S 50 40 40 40 4 40 4 73 73 . 0 53 140 54 481/2 221/2 8 3 137. 2 1/2
•
• For SCAOMO rule 1121 compliance (California only)
' • Side relief valve connection on model 41V50S only
1 Specify LP as when ordering Add "P" suffix to the model number Example 41VR4OP
a .
eir
RECEIVED
CITY OF TuKvou.
THESE UNITS ARE DESIGNED TO MEET
OR EXCEED A.N.S.I. (AMERICAN
NATIONAL STANDARDS INSTITUTE) AND
HAVE BEEN TESTED ACCORDING TO
D.O.E. TEST PROCEDURES AND MEET
OR EXCEED THE ENERGY EFFICIENCY
REQUIREMENTS OF NAECA, ASHRAE
STANDARD 90, BOCA CODE AND
ALL STATE ENERGY EFFICIENCY
PERFORMANCE CRITERIA FOR ENERGY
CONSUMING APPLIANCES.
Before purchasing this appliance, read
important energy cost and efficiency
information available from your retailer.
The number one choice of plumbing professionals.
RHEEM
MANUFACTURING
COMPANY
WATER
HEATER
DIVISION
101 Bell Road. P.O Box 244020, Montgomery, Alabama 36124.4020
PAINTED IN U.S.A
3.97 WP
RHEEMGLAS® Fury Plus Energy Miser
CONSTRUCTION FEATURES
1. R•Foam insulation —Rigid polyurethane foam for improved economy and fuel savings.
The use of our patented insulator foam stops allows R -Foam to be injected directly
between the tank and outer jacket. This uniform R -Foam application minimizes the
possibility of costly heat loss caused by uninsulated areas (voids) common to some
other foam processes.
2. Rheemglas Tank— Rheem• water heater tanks are made of special materials with
exacting care. The tank surface is coated with an exclusive porcelain formula called
Rheemglas and fused to the solid steel at 1600'. The result is a smooth, tough, glass -like
lining that effectively resists the corrosive attacks of hot water chemicals, thereby
assuring long water heater life. Tank is designed and tested to withstand 300 PSI
hydrostatic test pressure for working pressure of 150 PSI, A.N.S.I. Standard.
3. Gasmaster Burner — Durable aluminized steel construction. Designed for efficient, quiet
operation; precision port alignment; even heat transfer. Factory adjusted for natural gas.
LP models feature a durable stainless steel burner designed specifically for LP gas.
4. Flue Baffle —New design — special baffle restrictor discs provide greater retention of flue
gases. Keeps heat in flue longer for maximum heat dispersion to tank water. Retards air
movement through flue during standby periods, minimizing heat loss.
5. Robertshaw• Control— Combination thermostat with factory preset balanced pressure
regulation and built in E.C.O. (energy cut -off). LP models feature the R65RR control, the
most advanced LP gas control available.
6. Anode Rod — Equalizes aggressive water action; different types factory installed and
designed to match local water chemical characteristics throughout the U.S.
7. DIp Tube--A durable plastic formula, tougher, more heat resistant than ever before.
8. Relief Valve Opening —( %' N.P.T.) top connect Is exposed for faster, economical
installation.
9. Drain Valve —Non- metallic, corrosion proof, designed for quick draining.
10. The Draft Diverter —Low profile design is proven, efficient.
THE GASMASTER BURNER
Durable aluminized steel construction.
Designed for efficient, quiet operation;
precision port alignment, even heat
transfer.
Features energy saving low input pilot —
only 350 to 400 BTUH. Well protected to
maintain alignment, yet easy to light.
"In keeping with its policy of continuous progress and
product improvement, Rheem reserves the right to
make changes without notice'
FORM NO 101.9 REV. 9
a
as, 7‘gs7
SERIFS t t Iw '
Models with Input Rates fro
45,000 to 150,000 BTU/HR
[13 to 44 1 K :l
(U.S. Canv;dian Models)
444 )
1>u 1w
.
-` 1 ` , FtF
4 i tl3,+.. 0
r ....,
l3 ult.nr RS COPY
r:.
Al l v1;104110% n u1+
F 7 [..,, NA11N4
Ifi� s �;,ty
.1 _ -.: Y«7C:D+[rr._ �•al.�r�x+av�. 'Y'i+.•- - "1"SiiC1T� wtiL: �.:1T...',<::....,.✓:.... • k: «.__..... if1 :. .. - ...
_ .::zz
z:,z xrr:�lr
E rr ICIENCV
"� CENTIEIEU
7." ama
• ; lz
R TERI¢ `p'(® fl
FORM NO. G11 -449 REV. 2
Supersedes Form No. G11 -449 Rev 1
RECEIVED
CITY OF %Kta'II A
FEB 2 0 ?007
PERMIT CENTER
78%-8''% . A.F.U.E.
DOWN F LOW
G;A.. FURNACES
t
The Rheem® Criterion' II line of downflow gas furnaces is
designed for installation in closets, alcoves, utility rooms, or
attics. The design is certified by the American Gas Associa-
tion. Canadian models are certified by the Canadian Gas
Association.
Features
n Patented Turbulex�° heat exchanger, constructed of both
stainless and aluminized steel for the maximum in corro-
sion resistance.
• Low profile "34 inch" [864 mm] design is lighter and easier
to handle, and leaves room for optional equipmgnt.
e Both standing pilot and hot surface ignition models
available.
n Left or right side gas and electric inlet connections with
quick, simpie change.
ea Hot surface ignition models feature a new integrated
board with humidifier and electronic air cleaner hookups.
Insulated blower Compartment, a slow -open gas valve and
a specially designed draft inducer motor make it one of the
quietest furnaces on the market today.
al Pre -paint galvanized stool cubinct.
• Grab -holes in doors to aid in easy door removal and
replacement.
A variety of cooling coils r.n;l pk�nums designed to use with
Ahearn Criterion 11 gas furnaces are available as optional
accessories.
tA.F.U.E. (Annual Fuel U;.lui:tion F1ti
Enorgy lost procedures
<:y) cal in mxordanco with Department of
Mat- oSG
I «,<r„ = «f
1
1
z
w W
aa 2
JU
0
W =
N W
W
QQ
cn a
=
1--
Z �
I— O
w ~
w
U
O -
W W
u O
W
U
0
Z
•
Oral! Inducer Motor
Hot Surface Ignitor
with Remote Sense
(Hot Surface Ignition Models)
ST, EQUIPMENT
RHEEM CRr =RION II 78 -80%
DOWNFLOW GAS FURNACE
Pilot Assembly
(Standing Pilot Models)
:omplutely assembled and wired; induced draft; pressure switch; redundant
pain gas control; blower compartment door safety switch; solid stale time
,r.' .roe off blower control; limit control; manual shut -off valve, pressure
errJL.:ator for natural and L.P. (propane) gas; transformer; direct drive multi -
;peed blower motor. Furnaces are equipped with cooling /heating relay and
r r
'former (1OVA) ready for air conditioning applications. (Please note: a
. stat is not included as standard equipment.) Flame sensor diagnostics;
i.L.l. only twinning options, standing pilot models may n_ctt he twinned; fused
(scrondary), 3rd speed option for continuous fan; common
t /,., 0! ;+rar.:a; !Jr H.S.I.
COTE !unlace is not listed for use with fuels other than natural or L.F.
(propane) gas.
h c� nprete !elms of limited and other warranties are available at our
ales office, or through local installer.
Molded
Permanent Filter
Blower and
Control Box
Turbulex' Heat Exchanger
In -Shot Burners
and Gas Valve
All models can he convened by a qualified Rheem distributor or local service
dPaler to use L P. (propane) gas without changing burners. Factory approved
kits must be used to convert from natural to L.P. (propane) gas and may be
ordered as optional accessories from a Rheern parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form No. 92- 21519 -52
for U.S. models and Form No. 92- 21519 -53 for Canadian models.
NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition
is 100% lockout type.
•
•
MODEL NUMBERS
RGLH• SERIES
045AUSR
04MAUSR
• O4EAUSR
O4NAUSR
045AUSA
04EAUSA
050AUER
05MAUER ,
05EAUER
05NAUER
050AUEA
05EAUEA
067AUER
06MAUER
06EAUER
06NAUER
D67AUEA
06EAUEA
075AUER
07MAUER
• 07EAUER
07NAUER
075AUEA
07EAUEA
075AMGR
07MAMGR
07EAMGR
07NAMGR
075AMGA
07EAMGA
100AUER
10MAUER
10EAMER
10NAMER
100AUEA
10EAMEA
1008RJR
10EMRJR
10EBRJR
10NBRJR
100BRJA
10EBRJA
125ARJR
12MARJR
12EARJR
12NARJR
125ARJA
12EARJA
15OARJR
15MARJR
15EARJR
15NARJR
150ARJA
15EARJA
Input - BTU /Hr [kW] 'r
45.000 113]
50,000 1151
67.500 [ 19 81
75.000 [22]
75,000 (221
100.000 [29 3]
100.000 129 3j
1.'5.00 136 6]
150.000 (441
Heating Capacity BTU /Hr 1k WI .1'
36,000 (11)
41.000 [12]
54.000 116]
60.000 (18]
60.500 (18]
80.000 1231
81 000 (241
D9000 (291
120 000 135)
High Altitude Input IkW]
40,500 111 9]
45.000 (13]
60,800 117 8]
67,500 [19.8]
67.500 119.8]
90.000126.
90,000 [26 41
112 500 (33]
135.000 139 6]
High Altitude Output
32.900 [9.6)
36500 (10.7)
49,000 114 41
53.500 (15.71
54.000 (15 8]
72.000 [21.11
72.500 121 21 L!OOO (26 11
10.500 [31 5]
Heat Ext. Static Pressure (Val
.10 1.0251
10 (.0251
12 1.0291
.12 [.0291
12 [029]
15 (.037]
15 ] 037] 20 1 05]
20 ( 05)
11x6 =10'AU
Blower (DxW)[mmJ
11x6
[279 x 152]
11x6
[279 x 152]
11x6
[279 x 152]
11x6
[279 x 152]
11x7
[279 x 178]
1279x152]
11 x 7 = 10'AM
11x10 11x10
[279 x 254] [279 x 254]
11x10
(279 x 254]
1279 x 178
Motor H.P. (W)- Speeds (W1-
1 /2 -4 -PSC
1 /2 -4 -PSC
1 /2 -4 -PSC
1 /2 -4 -PSC
3 /4 -4 -PSC
1 /2.4 -PSC
3 /4.4 -PSC 3 /4.4 -PSC
3 /4 -4 -PSC
PSC Type
(373]
[373]
(373]
[373]
[559)
(3731
[559] (559)
[559]
Motor Full Load Amps
7.1
6.8
7.1
7.1
9.5
7.1
9.5 9.5
9.5
Heating Speed
MED -LOW
MED -LOW
MED -HIGH
MED -HIGH
MED -LOW
MED -HIGH
MED -LOW MED -LOW
MED -LOW
Cooling Speed
HIGH
HIGH
HIGH
HIGH
MED -HIGH
HIGH
MED -HIGH MED -HIGH
MED -HIGH
Cooling CFM 0.5" [kPa] E.S.P.
1200
1200
1200
1200
1600
1200
2000 2000
2000
(Nominal) [Us]
[566)
(566]
(5661
[5661
[755]
(566]
[944] (944]
(944)
Rated E.S.P. (In. W.C.) (kPa]
.50 [.12]
.50 (.12]
.50 1 121
.50 [.12)
.50 [.12]
.50 1.12]
.50 (.12) .50 (.12]
.50 1.12]
55-85 = 10'AU
Temperature Rise Range °F
30 -60
25 -55
30-60
40 -70
25 -55
[30.6-47.2)
40-70 40 -70
50 -80
[ °C]
[16.7 -33.3)
[13.9.30.6)
[16.7 -33.3]
[22.2 -38.9)
[13.9 -30.6]
45 -75 = 10'AM
[22.2.38.9] 122.2 -38.9)
(27.8 -44.4]
125 -41.7]
Max. Outlet Air Temp. °F
155
155
165
165
155 •
190
190 180
190
( °C]
[68.3]
(68.3)
[73.9]
[73.9]
[68.3]
[87.8]
[87.8] [82.2]
[87.8]
Standard Filter (mm]
(1) 14 x 20
[356 x 508]
(1) 14 x 20
[356 x 508]
(2) 12 x 20
[305 x 5081
(2) 12 x 20
(305 x 508]
(2) 12 x 20
[305 x 508]
(2) 12 x 20
[305 x 508]
(2) 14 x 20 (2) 14 x 20
[356 x 508] [356 x 508]
(2) 14 x 20
[356 x 508]
Approx. Shipping Weight (Lbs.)
85
85
105
105
105
115
120 140
150
[kg]: .
(38.6]
[38.6]
[47.6)
[47.6]
[47.6)
[52.2]
[54.4] 163.5]
(68.0]
AFUE- Standing Pilot Models O
78%
79.5%
78.4%
78.6%
79.2%
78%
78% 78.1%
78.5%
AFU E- S . Models O
81.1%
82.2%
80.7%
80.5%
81.1%
80.2%
80% 80%
80%
Californta Seasonal Efficiency-
H.S.1. /No Models
73.8/73.9
75.9/76.2
73.8/73.9
74A/74.9
75.1/75.5
75.2/75.2
74.7/74.7 75.2/75.3 •
76.0/75.9
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COS1 ANU EFEIUIENGY INFUHIVIAI IUN NWAILAbLt
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
U.S. AND CANADA MODELS ( DOWNFLOW
NOTES: All models are 115V, 60HZ, 10. Gas connection size for all models is 1/2' N.P.T.
p In accordance with D.O.E. test procedures.
(2) See Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519-53 for Canadian models for high altitude derate.
cm :arses rrr1= , *+m .0 "7 -0 . ,.-,;
MODE. IDENTIFICATION ---- DOWNFLOW MODELS
fi G L H -
Rheem Gas Downflow Design
Furnace Series
[ ) Desirrr,tes Metric Conversions
Standing
Pilot
07E
Heating Input Designation
NOx Electric NOx Input
Model Ignition Model BTU /HR
045 04M 04E 04N 45,000 [13 kW]
050 05M 05E 05N 50,000 [15 kW]
067 06M 06E 06N 67,500 [20 kW]
075 07M 07E 07N 75,000 [22 kW]
100 10M 10E 10N 100,000 [29 kW]
125 12M 12E 12N 125,000 [37 kW]
150 15M 15E 15N 150,000 [44 kW]
A U
Variations Blower
A = Std. Designation
Cabinet U = 11 x 6
B = Wide 1279 x 152 mm]
Cabinet M =11 x 7
[279 x 178 mm]
R =11x
[279 x 254 mm]
aszW -W:
E R
Heating & Cooling Fuel Type
Designation R = Natural Gas,
S = 500 -1200 CFM U.S. Standard
[236 -5013 Us] Furnace
E = 1100 -1330 CFM A = Natural Gas,
(519 -628 Ifs) Canadian
G = 1450 -1750 CFM Standard
(684 -826 L /s) Furnace
J = 1800 -2075 CFM
(850 -979 Us]
d is
GLii
..
s: r..'
f ,vl` O ,1
TY� i'/ l �
;
`!• .. •:
l '' a
}
14' 1 � ) ir t ;, ��'} ��/'•
' ` . �LS
._ '1"1. L
Y,;,;rr���;5 '�
/.
�a �
i >:
.F .C'�f� i.Y i . ,
r1 .r x
. t �.
.; C1,
L���I �
$IDE•,
�” "�'
: �:; "cs
, p t S
3 t•� 4 CI I � .
tl� r
6DF:i.6
11010
� r
1, v s t l{
°.i._r '' +':�;..
�,; ,r
*.i:E4t
.� 7 N f
1 , ; 1,,?. „
t y
A L 1
y j' r ,
f ` A7
x � .•1r1+,1')�
ri,6:; ",6
i �Ly4 •. L4�'
rJ�i+�'f � � i
. r ` �
�J7, � _�3}S`
. ,.
f lk 1p, "
1 4 Y
ri ) [111.G j 1� t
� �
41!�� f' -, 11
04, 05
14
[356]
12 [326]
10 /e [264]
O
13 [333]
0
4 0
0
1 [25]
3 [76]
6 [152] C1)1
85 [38.6]
06, 07
17
[445]
16 [415]
12 /e [308]
O
16 [422]
0
3 0
0
1 (25]
3 [76]
6 [152] cj)
105 [47.6]
10 (A)
17
[445]
161 [415]
12 [308]
0)
16 [422]
0
3 a
0
1 [25]
3 [76]
6 (152] CJ
115 [52.2]
10 (8)
21
(533]
19 [504]
13 [352]
O
20 [511]
0
0
0
1 [25]
3 [76]
6 [152] c3)
120 [54.4]
12
24
[622]
23 [593]
15 [397]
O
23 [600]
0
0
0
1 [25]
3 [76]
6 (152] 0
140 [63.5]
15
24
[622]
23 [593]
15 [397]
O
23 [600]
0
0
0
1 [25]
3 [76]
6 [152] 0)
150 [68]
)TES: m May reauire a 3'176 mm) to 4'1102 mml or 3'176 mml to 5'1127 mml adapter.
)OWI4FLOW DIMENSIONS
26 /e"
[676 mm)
LOW VOLTAGE
• ELECTRICAL
CONNECTION
(HIGH VOLTAGE)
2 613/i?
[681 mm)
• ( . 'y .
GAS CONNECTION
LEFT SIDE
] Designates Metric Conversions
f
6
157 mm)
(16 mm)
23
203/e (594 mm)
(518 mm)
5 /g" —�
TOP
A
R.A.
FRONT
3/
[19 mm)
BOTTOM 1/16
S.A
34"
E
5 /e" [16 mm)
)8 64 mm[
[502 mm)
19
3/4"
119mm)
23 e"
[594 mm)
Lamm' 03/e"
6
(157 mm)
{
'-.E]LE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
28416" [713 mm)
20'/?
r r [511 mm)
26
(676 mm)
1 /2" DIA. [13 mm)
i /n" DIA.
[22 mm)
1 DIA.
[35 mm)
24''/16"
[621 mm)
RIGHT SIDE
[16 mm)
e May be 0' [0 mm] with type B vent.
0 May be 1' [25 mm] with type B vent.
Furnaces must be vented In accordance with ANSI Z21.47-1993 • CAN /CGA- 2.3 -M93 venting table guidelines included with each furnace, and in accordance
w;th local codes.
FURNACE
" ..WIDTH' '
° IN.fmm1
PLENUM
WIDTH . '
- 'IN. Rim]
PLENUM ADAPTER '
' DOWNFLOW
- COIL
PLENUM
14 [356]
16
RXAA -C178
RXAL -B16BU
14 [356]
20 [514]
RXAA•C179
RXAL -B208U
17 [445]
16 [413]
RXAA -C: °6
RXAL -B16BU
17 [445]
20 /4 [514]
RXAA -C180
RXAL-B20BU
17 [445]
21 [549]
RXAA -C189
RXAL -B21BU
17'/2 [445]
25 [641]
RXAA -C181
RXAL -B25BU
21 [533]
22 [565)
RXAA -C182
RXAL -B22BU
21 [533]
25 [641]
RXAA -C183
RXAL -B25BU
24 [622]
25 [641 ]
RXAA -C184
RXAL -B25BU
24 [622]
21 [549]
RXAA-C190
RXAL-B21BU
COMBUSTIBLE
•FLOOR BASE;
`' USE WITH ';': '
' FURNACE SIZES`.
•, ' A .'
IN. [mm]
B
IN. [mm)
C
IN. [mm)
RXGC -B14
RGLH -04, 05
14
13 [337]
11 [286]
RXGC -B17
RGLH-06. 07, RGLH- 10( -)A
18 [457)
16 14251
143/4 [451]
RXGC -621
RGLH- 10( -)B
21 [546)
20 /4 1514)
18 [464]
RXGC -B24
RGLH -12, RGLH -15
25 [6351
23 1603)
21 [552]
ACCESSORIES- DOWNFL"!V
DOWNFLOW WARNING: Unit design is certified for installation on non -com-
bustible floor. A special factory supplied combustible floor sub -base is
required when installing on a combustible floor. Failure to install the sub -base
may result in fire, property damage and personal in(ury.
COMBUSTIBLE FLOOR BASE DIMENSIONS
• 7.1 1 /x"
046 mm)
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
_ ( • - acceding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
.197C* iNen i7�
.•: 114 U S A
19
[495 mm]
•
28
[721 mm)
FIBERGLASS
3 LB. (1.4 kg) DENSITY
9.96 BP
7
[184 am]
4" 3"
(102 mm) 176 mm)
r –I-
3" [76 mm)
RXGW -AAA01
Humidifier and Electronic Air Cleaner
Accessory Board for Robertshaw
Control RBC1 and Honeywell
ST9101 A 1014 Blower Controls.
NOTE: Available for standing pilot
models only.
L.; •
I A •1
FLOOR
PLENUM OR
DUCTWORK
NOTE: FLOOR OPENING
21 (546 mml x B
MAX. PLENUM SIZE
19 [495 mm] x C
1" [25 mm)
FIBERGLASS
3 LB. [1.4 kg) DENSITY
GENERAL TERMS OF LIMITED WARRANTY*
PLENUM DATA — "A" COILS
Plenum adapters are required in some instances for use on downflow applications
when plenum and furnace size do not match.
NOTE: See Form Number C11 -206 for MultiFlex coil data.
RXPF -F01 and F02
FOSSIL FUEL KIT —is for use with
Rheem Heat Pumps and Criterion II
warm air furnaces. RXPF -F02 meets
TVA requirements.
RXGF -CC*
FILTER RACK— Downflow top
return mount.
NOTE: Filter racks are shipped
without filters.
'Filters available through the
Universal Parts® Department.
Gas Heat Exchanger Limited Warranty Twenty (20) Years
Draft Inducer Limited Warranty Five (5) Years
Integrated Control Board
Limited Warranty Five (5) Years
(Standing Pilot and Hot Surface Control Boards)
Any Other Part One (1) Year
For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.
RHEEM
AIR CONDITIONING
DIVISION
P.O. Box 17010, Fort Smith, Arkansas 72917.7010
"In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice."
FORM NO 011.449 REV 2
supvrsednb run., Ru Gil 449 Rev I
BLOWER
:vmorEe".
NUMBE r
-RG1.H
SER11 S ,
O45AUS'•
'04MAUSR
04EAUS'
04NAUSR
PERFORMAP'
t
rBLOWE
i. �.SIZE a r
1111)
� c
11 x 6
(299 x 1521
sp . .;
fMOT R;
T x
11 11 ]
1/2
(373)
w
Norm
BLOWE, :,
, 4 E
. -
LOW
MED•L0
MED -HI
HIGH
IE DATA- DOWNFLOW MnDELS
�+ _ �wr
� ; : 1 ,
; ; q` � y , u ; n ii,,
/<r b2
' t 1 1 ^_:
685 [323]
980 (4631
1220 [576)
1465 [691)
,. :rrax..ar2'�'
if.i .,,,,,-.-
: - t , EXTERNAL
y 4411 ub5 k .
is '.; , [ . I ,.
650 (307)
955 [4511
1195 [564)
1440 1680]
k o ��..
5Nlati
PRESSURE.
' t3 l 4' I S
t 4,! [ :L 1 is.
615 [290]
930 [4391
1170 [552]
1405 (663)
... ,.h .
eifiiIR DL_.rERlk.
IN CHES•(kP ,� a1; �W A y TER . COLUMN y ,
r , t x • r r ,r .r .
° 4 [ 7Y� .4.> r
580 [2741
900 (4251
1135 (536)
1365 (644)
k. N .
::7,
c
a;.. . : '
, l %,
. 545 12571 -
870 (4111
1100 [519)
1325 [625]
;. ,,....,
ii .: -
w .. i4 • � ,
+� D ' Z
[' . , ;, i
5.10 .(241)
840 [396]
1065 [503)
1280 (604)
::,:t.'49*
: . y ' •
r
r t . Z ..,
470 r 1222)
805 [380)
1020 [4811
1230 [580]
050AUE•
05MAUER
05EAUE•
05NAUER
11 x 6
[279 x 1521
1/2
[373)
LOW
MED -LO
MED -HI
HIGH
735 (347]
1025 [484)
1185 [559]
1345 [635)
715
1015
1165
1330
(337)
(479)
[550)
(6281
690 [326]
995 (470)
1150 [543)
1310 (6181
660 (311)
975 [4601
1130 [533)
1295 [611)
635 (300)
955 [451)
1100 (519)
1265 [597]
605 [286]
930 [439)
1075 [507]
1235 [5831
575 [2711
905 [427]
1040 14911
1205 [5691
067AUE'
06MAUER
06EAUE•
06NAUER
075AUE•
07MAUER
07EAUE'
07EAUER
11 x 6
[279 x 152]
1/2
[373]
LOW
MED -LO
MED -HI
HIGH
835 (394]
990 [467]
1140 [5381
1300 [6141
820
975
1125
1290
[387)
(460]
[531]
[609]
800 [3781
955 [451]
1105 [522]
1265 [597]
775 [3661
935 1441)
1080 (510]
1245 [588]
750 [354)
905 (427]
1050 [4961
1215 [5731
720 [340]
875 1413)
1020 14811
1180 [557)
685 [323]
835 (394)
980 [463)
1140 (538]
075AMG•
07MAMGR
07EAMG'
07NAMGR
11 x 7
[279 x 178]
3/4
[559]
LOW
MED -LO
MED -HI
HIGH
1210 (571)
1580 [746)
1915 1904]
—
1205
1560
1880
2050
[569]
(736)
(887)
[967]
1195 [564]
1550 (732]
1825 18611
1995 (942)
1180 [557]
1530 [722]
1790 [845]
1940 [916]
1165 [550)
1495 [706)
1740 [8211
1885 [890]
1155 (5451
1465 [691]
1675 [791]
1835 [866]
1130 [533]
1430 [675]
1600 (7551
1770 [835)
1 :1 V ';?
10EAME•
10NAMER
I' n: s'•` :
11 x 7
[279 x 1781
r fix'`'..;
1/2
[373)
kla
MED -LO
MED -HI
HIGH
gt:93.5s1441 J*
1070 (505)
1240 [5851
1420 (6701
910a
1055
1210
1395
[429)".1
[498)
[5711
[658]
885r [t •81 `•':-
1040 1491]
1190 [562]
1370 [6471
t'855 i:[„4041c "-:: '
1010 [477)
1165 (550)
1340 [632]
. A25.t[3891" '`
980 (4631
1135 [536]
1305 [616]
i5'= ]3YOV..
945 (446)
1095 [5171
1265 [597]
4 -4 - .7.043591 ..
905 (427)
1055 [498]
1220 [576]
'+ z ri 4
100AUE*
10MAUER
t
11 x 6
[279 x 152]
ti
1/2
[3731
i ia.W
MED -LO
MED -HI
HIGH
piw$35:(4181. d
1020 (481]
1170 [552]
1330 [628]
• 865
1000
1160
1300
.•(4Q81 3
[4721
(5471
[6141
s:84A.1'139613t'::
980 [463]
1140 [538]
1270 [599]
_815y:.[3.851,7
965 (455]
1110 (524)
1235 [583]
t78D 1[37.31: 1'
930 [439)
1080 [5101
1200 (566]
Q.:.[359]'..:,:
895 (422]
1040 (491 ]
1160 [547)
?:135.i'
860 [406)
995 [4701
1115 [526]
100BRJ•
10MBRJR
10E8RJ•
10N8RJR
11 x 10
(279 x 254)
3/4
(5591
LOW
MED -LO
MED -HI
HIGH
1330 (6281
1690 [7981
—
—
1295
1670
2085
2410
[611]
[788]
(984]
[11371
1285 [606)
1655 [781]
2055 [970]
2355[1111]
1245 [588]
1615 [762]
2005 (946)
2305[1088]
1225 [5781
1585 [748]
1970 [930]
2240 [1057]
1205 [569]
1565 [739]
1945 (9181
2165(10221
1160 (547]
1525 [720]
1880 (8871
2100 [991]
125ARJ'
12MARJR
12EARJ•
12NARJR
11 x 10
[279 x 254]
3/4
[5591
LOW
MED -LO
MED -HI
HIGH
1330(628]
—
—
—
1295
1690
2090
2395
[611]
[798]
[9861
[1130)
1280 [604)
1660 [7831
2035 [960]
2335 [1102]
1240 [585]
1635 [772]
1985 [937)
2260 [1067)
1215 [573)
1580 [746)
1930 [911]
2185 [1031]
1210 [571)
1535 [724]
1850 (873]
2080 [9821
1175 [555]
1480 [698]
1785 [8421
1965 [927)
150ARJ'
• H 15MARJR
15EARJ•
1 5N/IRJR
11 x 10
(279 x 2541
3/4
[559]
LOW
MED -LO
MED -HI
HIGH
1300 [614]
1675 (791)
2105 [9931
—
1280
1650
2075
2340
(604]
[779]
[979]
[1104]
1230 [580]
1620 1765)
2035 [960]
2290 [1081]
1205 [569]
1570 1741 ]
1990 [939]
2215 [1045]
1170 [552)
1545 [729]
1955 [923]
2145 [10121
1115 [526)
1485 [701 ]
1900 [897]
2080 [9821
1030 [486]
1425 [673]
1815 [857]
1995 (942]
NtI ES: 'Designates
"R" for U.S. models, and "A" for Canadian n odels.
•
•'Not to be used as a heating speed.
Data compiled with factory filters installed.
[ ] Designates Metric Conversions
Z
�gg W
7U
.0 0
ww
N
J
W0
2
W
Z �
h- 0
W
2
U o
0 1-
W W
U. O
lll
_
O
Z
DEPARTMENTS:
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
TUES /THURS ROUTI G:
Please Route Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS: (ten days)
Approved 11 Approved with Conditions
CORRECTION DETERMINATION:
Approved El Approved with Conditions ri
REVIEWER'S INITIALS:
\PRROUTE.DOC
5/99
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: m02 -036 DATE: 02 -20 -02
PROJECT NAME: ,LOWER JUNCTION - LOT 5
SITE ADDRESS: XXX SOUTH 150 TH STREET
Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Is Issued
Buildin Division L - I Fire Prevention r7 Planning Division
3 - I'mo
Public Works n Structural ri Permit Coordinator
DUE DATE: 02-21-02
Incomplete n Not Applicable
No further Review Required
DUE DATE 03 -21 -02
n
Comments:
DATE:
Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
DUE DATE
Not Approved (attach comments) ri
DATE:
REGI STERED AS PROVIDED BY LAW AS
' CONST CONT GENERAL
REGIST : # UP. DATE
CCO1 TRYONCL013DH 02/11/2003
EFFECTIVE DATE 03/08/1999
TRYON CONCEPTS LLC
PO BOX 148.:
RENTON WA . 98057
7 _
Issued 'by DEPARTMENT OF LABOR AND INDUSTRIES
•