Loading...
HomeMy WebLinkAboutPermit M02-036 - LOWER JUNCTION - LOT 5LOWER JUNCTION LOT 5 5428 S 150 ST M02 -036 City of ijukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 8733000060 Address: 5428 S 150 ST TUKW Suite No: Tenant: Name: LOWER JUNCTION - LOT 5 Address: 5428 S 150 ST, TUKWILA WA Owner: Name: SCHERLER ARNOLD E Address: 5439 S 150TH ST, TUKWILA WA Contact Person: Name: DON TRYON Address: 14420 SE 84 ST, NEWCASTLE, WA Contractor: Name: TRYON CONCEPTS LLC Address: PO BOX 146, RENTON, WA Contractor License No: TRYONCL013DH DESCRIPTION OF WORK: INSTALL NEW FURNACE AND WATER HEATER INTO NEW SINGLE FAMILY RESIDENCE Value of Construction: Type of Fire Protection: Permit Center Authorized Signature: Signature: doc: Mech $4,000.00 N/A MECHANICAL PERMIT -i%'e Permit Number: MO2 -036 Issue Date: 01/06/2003 Permit Expires On: 07/05/2003 Phone: Phone: 425 255 -6518 Phone: 425 - 255 -6518 Expiration Date: 02/11/2003 Fees Collected: Uniform Mechnical Code Edition: Date: " z23 $70.25 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: /-6 3 Print Name: 2di✓ 1i2 (Feb A..) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -036 Printed: 01 -06 -2003 I 0 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 8733000060 Address: 5428 S 150 ST TUKW Suite No: Tenant: LOWER JUNCTION - LOT 5 PERMIT CONDITIONS Permit Number: MO2 -036 Status: ISSUED Applied Date: 02/20/2002 Issue Date: 01/06/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: .CDP°7 G Date: / (p -c) 3 Print Name: AA) 772vo .) MO2 -036 Printed: 01 -06 -2003 Project Name /Tenant: �.. LUGJE'!Z �UNCT� O 4) C01 S Value of chanical Equipment: of Site Address : City State /Zip: S. /SC) 14 S/ —7-(-11r4431 (6 cJw 9.',.X ' Tax Parsel Number: ' 3 - 4246 a Property Own .Ko Sc4.er /e f- !4) 6, _ 1 Phon ( ) 206 24 -e6(? Street Address: 5 , Stat Zip: S. /5c) -71 75 Kw 14 Fil 12 Fax #: ( ) Contractor: PA 5 ,4 Ti�6 PP5 M"�4)(33 DA Phone: S ) ( F es . ..07e 7 9 Street Address: �i City Stat Zip: /20 2 2 7 ?lee Ne kl,A -k ed Qpo3 Fax #: ((15) DZ o S -e « Contact Person: . .__.- A) (( � ;,) Ph one: y 255 as47 Street Address: /44242 S 'E 4.4 5, City St e/Zip: 4 6 () 9 k s 7 Fax 11 ?.,r ) 25 5. _ F6 Z BUILDING !OWNERORAUTHORIZEDAGENT:: Signature: ...—,--N � Date: 2 --2a r0 Z Print nam e:D !4) 6, _ 1 Phone: 4115 ) .2ss.4s l"• Fax II: (!{E5 ) 94771 Address: /44( St- .kw ..4 ',i" City /State/Zipkk //Q 624 p0o 11/2/99 Hier. pennit,due CITY OFT1►WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 STAFF t)SE ONLY Project Number: Permit Number. 1'►'102 •03(i Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL; PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done 14 b / e�peci 'c): I" /& 4 T G � !�t C re et K a Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LA WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: ,,?d2 Date application expires: ?NW I-0 a Application taken by: (initials) &CP ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C, over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. • Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal 11/2/99 m!acpmr.duc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Ire ,tel 11 tr WO fill! RECEIPT w W Parcel No.: 8733000060 Permit Number: MO2 -036 • ? . §. Address: 5428 S 150 ST TUKW Status: APPROVED N Suite No: Applied Date: 02/20/2002 ( _. Applicant: LOWER JUNCTION - LOT 5 Issue Date: N LL; W o Receipt No.: R03 -00010 Payment Amount: 70.25 2 g J , Initials: SKS Payment Date: 01/06/2003 11:53 AM u - D ; User ID: 1165 Balance: $0.00 = fy Z , Payee: TYRON CONCEPTS, LLC. P-; M 0 co TRANSACTION LIST: 0 N; Type Method Description Di- Payment Check 2863 70.25 Q', • w Z V N O Z ACCOUNT ITEM LIST: doc: Receipt City of Tukwila Current Pmts 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Amount MECHANICAL - RES PLAN CHECK - RES Description Account Code 000/322.100 000/345.830 56.20 14.05 Total: 70.25 ,4 ill. 01/07 9716 TOTAL 5051.50 Printed: 01 -06 -2003 • Project: + J liiv.ch 0 v' isl S Type of Inspection: 1 -S,V� Address: S L1 ;$ S , 1 50 S+ Date Called: - 1 - ‘,2 - Special Instructions: Date Wanted: a 1 . Requester: V\ Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Moz -o3fol Approved per applicable codes. El Corrections required prior to approval. COMMENTS: $r 0A Cov►" ? 01L Inspector: Date: - 0 3 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: (Date: 122:i'V;4•41' in;i2ii j,��ri:;3Ar97;7 ir4+ ?;t2,:�.%s3.`WA Z I W �U U co co w co IL w 0 u_ a co d I— O z �. D O N O 1— W uj iil! 52 Z P oJeect:. I I Y J onC - ho i -Lo Type spection• L — A v Address 5 R -S /50 37 Date Called: ' ,? f� , Special Instructions: Date Wanted 03 Requester: Phone o kiN- ;4;': >;::;e:'�'.:'.ti �,. +..Si Zvi +• x [ ti,:i',t;',n��:.) Approved'per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: V 7.00 REINSPECTION FE REQUIRED. Prio to inspection, fee must be paid at 6300 Southcenter B d., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Z rew 00 cow co � 0 w 0 ga u. Z z° LU Ili U� ON 0 I— W W g LLO Z Ui 0 z N. Project Name: y< < , ,,�,0 i Lo 70N c 77o�c) LD'7 5 `'-� �``� Address: 5/1 S. 1` Si Residential Building Permit Number: 45 1. Prescriptive Option W.S.E.C. Chapter 6, (check building permit option used): CI I. CI ii ❑III. CI iv. f CI vi. ❑VII. CI VIII. 2. House Square Footage (HSqFt) Z36/ 3. Heating System installed, (check system type below): El a. CITY a. Electric Resistance /21 BTU /h s . ft. RECEIVED P sq. OF TUKWILA ❑ b. Electric (forced air) /24 BTU /h per sq. ft. FEB 2 0 2002 ® c. Other Fuels (gas, heat pump) /27 BTU /h per sq. ft. PERMIT CENTER 4. Equipment: a. Make le lA b. Model gt4 K 675 c. Size in BTU's (oo oo 5. Calculation /(HSqFt) 23C•( (see line 2 above) BTU /h X 2 7 (see line 3 a, b, or c above) 63 - 741 BTU Equipment Maximum Size PERMIT APPLICATION #: M V ' o o 7/9/96 CITY Ot- TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 FEU {i _ OERS COPY Prescriptive Heating System Sizing for Single Family Homes - New Construction Washington State Energy Code Chapter 9, Clin t o +ne'1ttk p 'PRO'1E 0 DEC 2 3 ?002 TW !iJILiJ H -6 Applicant's Signature: l/Ly0' . Date: Z' —o Z Moe- o� t — Ca4-S u P.P. & S. Heating & A/C Inc. 12022 98th Ave. NE Kirkland, WA 98034 ref:45 A 6,45 re.Razto ,A-a& ,Mln)G, 0.41) , c'og s cr a gook_ . -WE sz,v u,J iT in+4 / SI : (Z,~ 507. UPS 1.h- — 1 9 FYN pc.%TPuT" 1-{P Wi so sA(.. Gays Lomat& itir.gcrsk 1�U og unlnrs; CITY OF TUKWILA APPROVE!) DEC 2 3 2002 t ar JZ , f •V /� a 1 Moe •ow RHEEMGLAS Fury Plus High Performance, Energy Miser® rmosavew.e... Gas Water Heater CITY OF Ti;vA;LA Available in 40 and 50 gallon tall - 30 and 40 gallon lowboy models DEC 23 2c • 5-Year Limited Tank Warranty* • 1-Year Limited Parts Warranty* • High performance and recovery • Patented R-Foam® insulation process for FEB 2 0 2002 superior heat retention • Gasmaster burner with precision port PERMII t 'Ef‘J ER alignment for even heat transfer • Heat saving flue baffle design • Compliant with many gas utility incentive programs** • Meets or exceeds National Appliance Energy Conservation Act (NAECA) requirements • See Residential Warranty Inlormation Brochure for complete warranty Information - 40.000 BTU models only. SPECIFICATIONS Gas Input First Hour T ; Tank in 111°i/sands Recovery In oeuyely ; EliiLnEPS COPY Roughing in Dimensions Y Model Ca BTU/Hr. G.P.H. Rating 'Enlit0Y (Shown in Inches) ' p. L____________ ' P Numhert GaN. 90 Rise G.P.H. Factor ; Wght.. ' E LP Lbs. Nal. 'Burner Nat. LP Nat. LP ABCD, EF CH 41VR40 40 40 40 40 4 40 4 68 68 0.62 127 61% 581/2 21 8 3 131/2 2 1/2 41VR40N 40 375 — 40 4 — 68 — 0.62 127 61 581/2 21 8 3 131/2 2 1/2 A L 41VR50 ; 50 40 40 40.4 40.4 74 74 I 0.62 151 60 571/2 • 23 8 ' 3 ' 131/2 2 1 /2 41VR50N• 50 40 — 404 — 74 — 0 62 151 60Y, 571/2 23 8 3 131/2 2 1/2 411P0S 30 34 34 344 344 54 54 0.58 109 501/2 461/2 17 8 3 131/2 2 411/40S 40 37 37 374 37 4 65 65 0.56 138 521/2 481/2 19 8 3 131/2 2 1/2 . _ . . . BOY - 41V50S 50 40 40 40 4 40 4 73 73 . 0 53 140 54 481/2 221/2 8 3 137. 2 1/2 • • For SCAOMO rule 1121 compliance (California only) ' • Side relief valve connection on model 41V50S only 1 Specify LP as when ordering Add "P" suffix to the model number Example 41VR4OP a . eir RECEIVED CITY OF TuKvou. THESE UNITS ARE DESIGNED TO MEET OR EXCEED A.N.S.I. (AMERICAN NATIONAL STANDARDS INSTITUTE) AND HAVE BEEN TESTED ACCORDING TO D.O.E. TEST PROCEDURES AND MEET OR EXCEED THE ENERGY EFFICIENCY REQUIREMENTS OF NAECA, ASHRAE STANDARD 90, BOCA CODE AND ALL STATE ENERGY EFFICIENCY PERFORMANCE CRITERIA FOR ENERGY CONSUMING APPLIANCES. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. The number one choice of plumbing professionals. RHEEM MANUFACTURING COMPANY WATER HEATER DIVISION 101 Bell Road. P.O Box 244020, Montgomery, Alabama 36124.4020 PAINTED IN U.S.A 3.97 WP RHEEMGLAS® Fury Plus Energy Miser CONSTRUCTION FEATURES 1. R•Foam insulation —Rigid polyurethane foam for improved economy and fuel savings. The use of our patented insulator foam stops allows R -Foam to be injected directly between the tank and outer jacket. This uniform R -Foam application minimizes the possibility of costly heat loss caused by uninsulated areas (voids) common to some other foam processes. 2. Rheemglas Tank— Rheem• water heater tanks are made of special materials with exacting care. The tank surface is coated with an exclusive porcelain formula called Rheemglas and fused to the solid steel at 1600'. The result is a smooth, tough, glass -like lining that effectively resists the corrosive attacks of hot water chemicals, thereby assuring long water heater life. Tank is designed and tested to withstand 300 PSI hydrostatic test pressure for working pressure of 150 PSI, A.N.S.I. Standard. 3. Gasmaster Burner — Durable aluminized steel construction. Designed for efficient, quiet operation; precision port alignment; even heat transfer. Factory adjusted for natural gas. LP models feature a durable stainless steel burner designed specifically for LP gas. 4. Flue Baffle —New design — special baffle restrictor discs provide greater retention of flue gases. Keeps heat in flue longer for maximum heat dispersion to tank water. Retards air movement through flue during standby periods, minimizing heat loss. 5. Robertshaw• Control— Combination thermostat with factory preset balanced pressure regulation and built in E.C.O. (energy cut -off). LP models feature the R65RR control, the most advanced LP gas control available. 6. Anode Rod — Equalizes aggressive water action; different types factory installed and designed to match local water chemical characteristics throughout the U.S. 7. DIp Tube--A durable plastic formula, tougher, more heat resistant than ever before. 8. Relief Valve Opening —( %' N.P.T.) top connect Is exposed for faster, economical installation. 9. Drain Valve —Non- metallic, corrosion proof, designed for quick draining. 10. The Draft Diverter —Low profile design is proven, efficient. THE GASMASTER BURNER Durable aluminized steel construction. Designed for efficient, quiet operation; precision port alignment, even heat transfer. Features energy saving low input pilot — only 350 to 400 BTUH. Well protected to maintain alignment, yet easy to light. "In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice' FORM NO 101.9 REV. 9 a as, 7‘gs7 SERIFS t t Iw ' Models with Input Rates fro 45,000 to 150,000 BTU/HR [13 to 44 1 K :l (U.S. Canv;dian Models) 444 ) 1>u 1w . -` 1 ` , FtF 4 i tl3,+.. 0 r ...., l3 ult.nr RS COPY r:. Al l v1;104110% n u1+ F 7 [..,, NA11N4 Ifi� s �;,ty .1 _ -.: Y«7C:D+[rr._ �•al.�r�x+av�. 'Y'i+.•- - "1"SiiC1T� wtiL: �.:1T...',<::....,.✓:.... • k: «.__..... if1 :. .. - ... _ .::zz z:,z xrr:�lr E rr ICIENCV "� CENTIEIEU 7." ama • ; lz R TERI¢ `p'(® fl FORM NO. G11 -449 REV. 2 Supersedes Form No. G11 -449 Rev 1 RECEIVED CITY OF %Kta'II A FEB 2 0 ?007 PERMIT CENTER 78%-8''% . A.F.U.E. DOWN F LOW G;A.. FURNACES t The Rheem® Criterion' II line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by the American Gas Associa- tion. Canadian models are certified by the Canadian Gas Association. Features n Patented Turbulex�° heat exchanger, constructed of both stainless and aluminized steel for the maximum in corro- sion resistance. • Low profile "34 inch" [864 mm] design is lighter and easier to handle, and leaves room for optional equipmgnt. e Both standing pilot and hot surface ignition models available. n Left or right side gas and electric inlet connections with quick, simpie change. ea Hot surface ignition models feature a new integrated board with humidifier and electronic air cleaner hookups. Insulated blower Compartment, a slow -open gas valve and a specially designed draft inducer motor make it one of the quietest furnaces on the market today. al Pre -paint galvanized stool cubinct. • Grab -holes in doors to aid in easy door removal and replacement. A variety of cooling coils r.n;l pk�nums designed to use with Ahearn Criterion 11 gas furnaces are available as optional accessories. tA.F.U.E. (Annual Fuel U;.lui:tion F1ti Enorgy lost procedures <:y) cal in mxordanco with Department of Mat- oSG I «,<r„ = «f 1 1 z w W aa 2 JU 0 W = N W W QQ cn a = 1-- Z � I— O w ~ w U O - W W u O W U 0 Z • Oral! Inducer Motor Hot Surface Ignitor with Remote Sense (Hot Surface Ignition Models) ST, EQUIPMENT RHEEM CRr =RION II 78 -80% DOWNFLOW GAS FURNACE Pilot Assembly (Standing Pilot Models) :omplutely assembled and wired; induced draft; pressure switch; redundant pain gas control; blower compartment door safety switch; solid stale time ,r.' .roe off blower control; limit control; manual shut -off valve, pressure errJL.:ator for natural and L.P. (propane) gas; transformer; direct drive multi - ;peed blower motor. Furnaces are equipped with cooling /heating relay and r r 'former (1OVA) ready for air conditioning applications. (Please note: a . stat is not included as standard equipment.) Flame sensor diagnostics; i.L.l. only twinning options, standing pilot models may n_ctt he twinned; fused (scrondary), 3rd speed option for continuous fan; common t /,., 0! ;+rar.:a; !Jr H.S.I. COTE !unlace is not listed for use with fuels other than natural or L.F. (propane) gas. h c� nprete !elms of limited and other warranties are available at our ales office, or through local installer. Molded Permanent Filter Blower and Control Box Turbulex' Heat Exchanger In -Shot Burners and Gas Valve All models can he convened by a qualified Rheem distributor or local service dPaler to use L P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheern parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519 -53 for Canadian models. NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition is 100% lockout type. • • MODEL NUMBERS RGLH• SERIES 045AUSR 04MAUSR • O4EAUSR O4NAUSR 045AUSA 04EAUSA 050AUER 05MAUER , 05EAUER 05NAUER 050AUEA 05EAUEA 067AUER 06MAUER 06EAUER 06NAUER D67AUEA 06EAUEA 075AUER 07MAUER • 07EAUER 07NAUER 075AUEA 07EAUEA 075AMGR 07MAMGR 07EAMGR 07NAMGR 075AMGA 07EAMGA 100AUER 10MAUER 10EAMER 10NAMER 100AUEA 10EAMEA 1008RJR 10EMRJR 10EBRJR 10NBRJR 100BRJA 10EBRJA 125ARJR 12MARJR 12EARJR 12NARJR 125ARJA 12EARJA 15OARJR 15MARJR 15EARJR 15NARJR 150ARJA 15EARJA Input - BTU /Hr [kW] 'r 45.000 113] 50,000 1151 67.500 [ 19 81 75.000 [22] 75,000 (221 100.000 [29 3] 100.000 129 3j 1.'5.00 136 6] 150.000 (441 Heating Capacity BTU /Hr 1k WI .1' 36,000 (11) 41.000 [12] 54.000 116] 60.000 (18] 60.500 (18] 80.000 1231 81 000 (241 D9000 (291 120 000 135) High Altitude Input IkW] 40,500 111 9] 45.000 (13] 60,800 117 8] 67,500 [19.8] 67.500 119.8] 90.000126. 90,000 [26 41 112 500 (33] 135.000 139 6] High Altitude Output 32.900 [9.6) 36500 (10.7) 49,000 114 41 53.500 (15.71 54.000 (15 8] 72.000 [21.11 72.500 121 21 L!OOO (26 11 10.500 [31 5] Heat Ext. Static Pressure (Val .10 1.0251 10 (.0251 12 1.0291 .12 [.0291 12 [029] 15 (.037] 15 ] 037] 20 1 05] 20 ( 05) 11x6 =10'AU Blower (DxW)[mmJ 11x6 [279 x 152] 11x6 [279 x 152] 11x6 [279 x 152] 11x6 [279 x 152] 11x7 [279 x 178] 1279x152] 11 x 7 = 10'AM 11x10 11x10 [279 x 254] [279 x 254] 11x10 (279 x 254] 1279 x 178 Motor H.P. (W)- Speeds (W1- 1 /2 -4 -PSC 1 /2 -4 -PSC 1 /2 -4 -PSC 1 /2 -4 -PSC 3 /4 -4 -PSC 1 /2.4 -PSC 3 /4.4 -PSC 3 /4.4 -PSC 3 /4 -4 -PSC PSC Type (373] [373] (373] [373] [559) (3731 [559] (559) [559] Motor Full Load Amps 7.1 6.8 7.1 7.1 9.5 7.1 9.5 9.5 9.5 Heating Speed MED -LOW MED -LOW MED -HIGH MED -HIGH MED -LOW MED -HIGH MED -LOW MED -LOW MED -LOW Cooling Speed HIGH HIGH HIGH HIGH MED -HIGH HIGH MED -HIGH MED -HIGH MED -HIGH Cooling CFM 0.5" [kPa] E.S.P. 1200 1200 1200 1200 1600 1200 2000 2000 2000 (Nominal) [Us] [566) (566] (5661 [5661 [755] (566] [944] (944] (944) Rated E.S.P. (In. W.C.) (kPa] .50 [.12] .50 (.12] .50 1 121 .50 [.12) .50 [.12] .50 1.12] .50 (.12) .50 (.12] .50 1.12] 55-85 = 10'AU Temperature Rise Range °F 30 -60 25 -55 30-60 40 -70 25 -55 [30.6-47.2) 40-70 40 -70 50 -80 [ °C] [16.7 -33.3) [13.9.30.6) [16.7 -33.3] [22.2 -38.9) [13.9 -30.6] 45 -75 = 10'AM [22.2.38.9] 122.2 -38.9) (27.8 -44.4] 125 -41.7] Max. Outlet Air Temp. °F 155 155 165 165 155 • 190 190 180 190 ( °C] [68.3] (68.3) [73.9] [73.9] [68.3] [87.8] [87.8] [82.2] [87.8] Standard Filter (mm] (1) 14 x 20 [356 x 508] (1) 14 x 20 [356 x 508] (2) 12 x 20 [305 x 5081 (2) 12 x 20 (305 x 508] (2) 12 x 20 [305 x 508] (2) 12 x 20 [305 x 508] (2) 14 x 20 (2) 14 x 20 [356 x 508] [356 x 508] (2) 14 x 20 [356 x 508] Approx. Shipping Weight (Lbs.) 85 85 105 105 105 115 120 140 150 [kg]: . (38.6] [38.6] [47.6) [47.6] [47.6) [52.2] [54.4] 163.5] (68.0] AFUE- Standing Pilot Models O 78% 79.5% 78.4% 78.6% 79.2% 78% 78% 78.1% 78.5% AFU E- S . Models O 81.1% 82.2% 80.7% 80.5% 81.1% 80.2% 80% 80% 80% Californta Seasonal Efficiency- H.S.1. /No Models 73.8/73.9 75.9/76.2 73.8/73.9 74A/74.9 75.1/75.5 75.2/75.2 74.7/74.7 75.2/75.3 • 76.0/75.9 BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COS1 ANU EFEIUIENGY INFUHIVIAI IUN NWAILAbLt FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS U.S. AND CANADA MODELS ( DOWNFLOW NOTES: All models are 115V, 60HZ, 10. Gas connection size for all models is 1/2' N.P.T. p In accordance with D.O.E. test procedures. (2) See Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519-53 for Canadian models for high altitude derate. cm :arses rrr1= , *+m .0 "7 -0 . ,.-,; MODE. IDENTIFICATION ---- DOWNFLOW MODELS fi G L H - Rheem Gas Downflow Design Furnace Series [ ) Desirrr,tes Metric Conversions Standing Pilot 07E Heating Input Designation NOx Electric NOx Input Model Ignition Model BTU /HR 045 04M 04E 04N 45,000 [13 kW] 050 05M 05E 05N 50,000 [15 kW] 067 06M 06E 06N 67,500 [20 kW] 075 07M 07E 07N 75,000 [22 kW] 100 10M 10E 10N 100,000 [29 kW] 125 12M 12E 12N 125,000 [37 kW] 150 15M 15E 15N 150,000 [44 kW] A U Variations Blower A = Std. Designation Cabinet U = 11 x 6 B = Wide 1279 x 152 mm] Cabinet M =11 x 7 [279 x 178 mm] R =11x [279 x 254 mm] aszW -W: E R Heating & Cooling Fuel Type Designation R = Natural Gas, S = 500 -1200 CFM U.S. Standard [236 -5013 Us] Furnace E = 1100 -1330 CFM A = Natural Gas, (519 -628 Ifs) Canadian G = 1450 -1750 CFM Standard (684 -826 L /s) Furnace J = 1800 -2075 CFM (850 -979 Us] d is GLii .. s: r..' f ,vl` O ,1 TY� i'/ l � ; `!• .. •: l '' a } 14' 1 � ) ir t ;, ��'} ��/'• ' ` . �LS ._ '1"1. L Y,;,;rr���;5 '� /. �a � i >: .F .C'�f� i.Y i . , r1 .r x . t �. .; C1, L���I � $IDE•, �” "�' : �:; "cs , p t S 3 t•� 4 CI I � . tl� r 6DF:i.6 11010 � r 1, v s t l{ °.i._r '' +':�;.. �,; ,r *.i:E4t .� 7 N f 1 , ; 1,,?. „ t y A L 1 y j' r , f ` A7 x � .•1r1+,1')� ri,6:; ",6 i �Ly4 •. L4�' rJ�i+�'f � � i . r ` � �J7, � _�3}S` . ,. f lk 1p, " 1 4 Y ri ) [111.G j 1� t � � 41!�� f' -, 11 04, 05 14 [356] 12 [326] 10 /e [264] O 13 [333] 0 4 0 0 1 [25] 3 [76] 6 [152] C1)1 85 [38.6] 06, 07 17 [445] 16 [415] 12 /e [308] O 16 [422] 0 3 0 0 1 (25] 3 [76] 6 [152] cj) 105 [47.6] 10 (A) 17 [445] 161 [415] 12 [308] 0) 16 [422] 0 3 a 0 1 [25] 3 [76] 6 (152] CJ 115 [52.2] 10 (8) 21 (533] 19 [504] 13 [352] O 20 [511] 0 0 0 1 [25] 3 [76] 6 [152] c3) 120 [54.4] 12 24 [622] 23 [593] 15 [397] O 23 [600] 0 0 0 1 [25] 3 [76] 6 (152] 0 140 [63.5] 15 24 [622] 23 [593] 15 [397] O 23 [600] 0 0 0 1 [25] 3 [76] 6 [152] 0) 150 [68] )TES: m May reauire a 3'176 mm) to 4'1102 mml or 3'176 mml to 5'1127 mml adapter. )OWI4FLOW DIMENSIONS 26 /e" [676 mm) LOW VOLTAGE • ELECTRICAL CONNECTION (HIGH VOLTAGE) 2 613/i? [681 mm) • ( . 'y . GAS CONNECTION LEFT SIDE ] Designates Metric Conversions f 6 157 mm) (16 mm) 23 203/e (594 mm) (518 mm) 5 /g" —� TOP A R.A. FRONT 3/ [19 mm) BOTTOM 1/16 S.A 34" E 5 /e" [16 mm) )8 64 mm[ [502 mm) 19 3/4" 119mm) 23 e" [594 mm) Lamm' 03/e" 6 (157 mm) { '-.E]LE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] 28416" [713 mm) 20'/? r r [511 mm) 26 (676 mm) 1 /2" DIA. [13 mm) i /n" DIA. [22 mm) 1 DIA. [35 mm) 24''/16" [621 mm) RIGHT SIDE [16 mm) e May be 0' [0 mm] with type B vent. 0 May be 1' [25 mm] with type B vent. Furnaces must be vented In accordance with ANSI Z21.47-1993 • CAN /CGA- 2.3 -M93 venting table guidelines included with each furnace, and in accordance w;th local codes. FURNACE " ..WIDTH' ' ° IN.fmm1 PLENUM WIDTH . ' - 'IN. Rim] PLENUM ADAPTER ' ' DOWNFLOW - COIL PLENUM 14 [356] 16 RXAA -C178 RXAL -B16BU 14 [356] 20 [514] RXAA•C179 RXAL -B208U 17 [445] 16 [413] RXAA -C: °6 RXAL -B16BU 17 [445] 20 /4 [514] RXAA -C180 RXAL-B20BU 17 [445] 21 [549] RXAA -C189 RXAL -B21BU 17'/2 [445] 25 [641] RXAA -C181 RXAL -B25BU 21 [533] 22 [565) RXAA -C182 RXAL -B22BU 21 [533] 25 [641] RXAA -C183 RXAL -B25BU 24 [622] 25 [641 ] RXAA -C184 RXAL -B25BU 24 [622] 21 [549] RXAA-C190 RXAL-B21BU COMBUSTIBLE •FLOOR BASE; `' USE WITH ';': ' ' FURNACE SIZES`. •, ' A .' IN. [mm] B IN. [mm) C IN. [mm) RXGC -B14 RGLH -04, 05 14 13 [337] 11 [286] RXGC -B17 RGLH-06. 07, RGLH- 10( -)A 18 [457) 16 14251 143/4 [451] RXGC -621 RGLH- 10( -)B 21 [546) 20 /4 1514) 18 [464] RXGC -B24 RGLH -12, RGLH -15 25 [6351 23 1603) 21 [552] ACCESSORIES- DOWNFL"!V DOWNFLOW WARNING: Unit design is certified for installation on non -com- bustible floor. A special factory supplied combustible floor sub -base is required when installing on a combustible floor. Failure to install the sub -base may result in fire, property damage and personal in(ury. COMBUSTIBLE FLOOR BASE DIMENSIONS • 7.1 1 /x" 046 mm) Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. _ ( • - acceding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. .197C* iNen i7� .•: 114 U S A 19 [495 mm] • 28 [721 mm) FIBERGLASS 3 LB. (1.4 kg) DENSITY 9.96 BP 7 [184 am] 4" 3" (102 mm) 176 mm) r –I- 3" [76 mm) RXGW -AAA01 Humidifier and Electronic Air Cleaner Accessory Board for Robertshaw Control RBC1 and Honeywell ST9101 A 1014 Blower Controls. NOTE: Available for standing pilot models only. L.; • I A •1 FLOOR PLENUM OR DUCTWORK NOTE: FLOOR OPENING 21 (546 mml x B MAX. PLENUM SIZE 19 [495 mm] x C 1" [25 mm) FIBERGLASS 3 LB. [1.4 kg) DENSITY GENERAL TERMS OF LIMITED WARRANTY* PLENUM DATA — "A" COILS Plenum adapters are required in some instances for use on downflow applications when plenum and furnace size do not match. NOTE: See Form Number C11 -206 for MultiFlex coil data. RXPF -F01 and F02 FOSSIL FUEL KIT —is for use with Rheem Heat Pumps and Criterion II warm air furnaces. RXPF -F02 meets TVA requirements. RXGF -CC* FILTER RACK— Downflow top return mount. NOTE: Filter racks are shipped without filters. 'Filters available through the Universal Parts® Department. Gas Heat Exchanger Limited Warranty Twenty (20) Years Draft Inducer Limited Warranty Five (5) Years Integrated Control Board Limited Warranty Five (5) Years (Standing Pilot and Hot Surface Control Boards) Any Other Part One (1) Year For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. RHEEM AIR CONDITIONING DIVISION P.O. Box 17010, Fort Smith, Arkansas 72917.7010 "In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice." FORM NO 011.449 REV 2 supvrsednb run., Ru Gil 449 Rev I BLOWER :vmorEe". NUMBE r -RG1.H SER11 S , O45AUS'• '04MAUSR 04EAUS' 04NAUSR PERFORMAP' t rBLOWE i. �.SIZE a r 1111) � c 11 x 6 (299 x 1521 sp . .; fMOT R; T x 11 11 ] 1/2 (373) w Norm BLOWE, :, , 4 E . - LOW MED•L0 MED -HI HIGH IE DATA- DOWNFLOW MnDELS �+ _ �wr � ; : 1 , ; ; q` � y , u ; n ii,, /<r b2 ' t 1 1 ^_: 685 [323] 980 (4631 1220 [576) 1465 [691) ,. :rrax..ar2'�' if.i .,,,,,-.- : - t , EXTERNAL y 4411 ub5 k . is '.; , [ . I ,. 650 (307) 955 [4511 1195 [564) 1440 1680] k o ��.. 5Nlati PRESSURE. ' t3 l 4' I S t 4,! [ :L 1 is. 615 [290] 930 [4391 1170 [552] 1405 (663) ... ,.h . eifiiIR DL_.rERlk. IN CHES•(kP ,� a1; �W A y TER . COLUMN y , r , t x • r r ,r .r . ° 4 [ 7Y� .4.> r 580 [2741 900 (4251 1135 (536) 1365 (644) k. N . ::7, c a;.. . : ' , l %, . 545 12571 - 870 (4111 1100 [519) 1325 [625] ;. ,,...., ii .: - w .. i4 • � , +� D ' Z [' . , ;, i 5.10 .(241) 840 [396] 1065 [503) 1280 (604) ::,:t.'49* : . y ' • r r t . Z .., 470 r 1222) 805 [380) 1020 [4811 1230 [580] 050AUE• 05MAUER 05EAUE• 05NAUER 11 x 6 [279 x 1521 1/2 [373) LOW MED -LO MED -HI HIGH 735 (347] 1025 [484) 1185 [559] 1345 [635) 715 1015 1165 1330 (337) (479) [550) (6281 690 [326] 995 (470) 1150 [543) 1310 (6181 660 (311) 975 [4601 1130 [533) 1295 [611) 635 (300) 955 [451) 1100 (519) 1265 [597] 605 [286] 930 [439) 1075 [507] 1235 [5831 575 [2711 905 [427] 1040 14911 1205 [5691 067AUE' 06MAUER 06EAUE• 06NAUER 075AUE• 07MAUER 07EAUE' 07EAUER 11 x 6 [279 x 152] 1/2 [373] LOW MED -LO MED -HI HIGH 835 (394] 990 [467] 1140 [5381 1300 [6141 820 975 1125 1290 [387) (460] [531] [609] 800 [3781 955 [451] 1105 [522] 1265 [597] 775 [3661 935 1441) 1080 (510] 1245 [588] 750 [354) 905 (427] 1050 [4961 1215 [5731 720 [340] 875 1413) 1020 14811 1180 [557) 685 [323] 835 (394) 980 [463) 1140 (538] 075AMG• 07MAMGR 07EAMG' 07NAMGR 11 x 7 [279 x 178] 3/4 [559] LOW MED -LO MED -HI HIGH 1210 (571) 1580 [746) 1915 1904] — 1205 1560 1880 2050 [569] (736) (887) [967] 1195 [564] 1550 (732] 1825 18611 1995 (942) 1180 [557] 1530 [722] 1790 [845] 1940 [916] 1165 [550) 1495 [706) 1740 [8211 1885 [890] 1155 (5451 1465 [691] 1675 [791] 1835 [866] 1130 [533] 1430 [675] 1600 (7551 1770 [835) 1 :1 V ';? 10EAME• 10NAMER I' n: s'•` : 11 x 7 [279 x 1781 r fix'`'..; 1/2 [373) kla MED -LO MED -HI HIGH gt:93.5s1441 J* 1070 (505) 1240 [5851 1420 (6701 910a 1055 1210 1395 [429)".1 [498) [5711 [658] 885r [t •81 `•':- 1040 1491] 1190 [562] 1370 [6471 t'855 i:[„4041c "-:: ' 1010 [477) 1165 (550) 1340 [632] . A25.t[3891" '` 980 (4631 1135 [536] 1305 [616] i5'= ]3YOV.. 945 (446) 1095 [5171 1265 [597] 4 -4 - .7.043591 .. 905 (427) 1055 [498] 1220 [576] '+ z ri 4 100AUE* 10MAUER t 11 x 6 [279 x 152] ti 1/2 [3731 i ia.W MED -LO MED -HI HIGH piw$35:(4181. d 1020 (481] 1170 [552] 1330 [628] • 865 1000 1160 1300 .•(4Q81 3 [4721 (5471 [6141 s:84A.1'139613t':: 980 [463] 1140 [538] 1270 [599] _815y:.[3.851,7 965 (455] 1110 (524) 1235 [583] t78D 1[37.31: 1' 930 [439) 1080 [5101 1200 (566] Q.:.[359]'..:,: 895 (422] 1040 (491 ] 1160 [547) ?:135.i' 860 [406) 995 [4701 1115 [526] 100BRJ• 10MBRJR 10E8RJ• 10N8RJR 11 x 10 (279 x 254) 3/4 (5591 LOW MED -LO MED -HI HIGH 1330 (6281 1690 [7981 — — 1295 1670 2085 2410 [611] [788] (984] [11371 1285 [606) 1655 [781] 2055 [970] 2355[1111] 1245 [588] 1615 [762] 2005 (946) 2305[1088] 1225 [5781 1585 [748] 1970 [930] 2240 [1057] 1205 [569] 1565 [739] 1945 (9181 2165(10221 1160 (547] 1525 [720] 1880 (8871 2100 [991] 125ARJ' 12MARJR 12EARJ• 12NARJR 11 x 10 [279 x 254] 3/4 [5591 LOW MED -LO MED -HI HIGH 1330(628] — — — 1295 1690 2090 2395 [611] [798] [9861 [1130) 1280 [604) 1660 [7831 2035 [960] 2335 [1102] 1240 [585] 1635 [772] 1985 [937) 2260 [1067) 1215 [573) 1580 [746) 1930 [911] 2185 [1031] 1210 [571) 1535 [724] 1850 (873] 2080 [9821 1175 [555] 1480 [698] 1785 [8421 1965 [927) 150ARJ' • H 15MARJR 15EARJ• 1 5N/IRJR 11 x 10 (279 x 2541 3/4 [559] LOW MED -LO MED -HI HIGH 1300 [614] 1675 (791) 2105 [9931 — 1280 1650 2075 2340 (604] [779] [979] [1104] 1230 [580] 1620 1765) 2035 [960] 2290 [1081] 1205 [569] 1570 1741 ] 1990 [939] 2215 [1045] 1170 [552) 1545 [729] 1955 [923] 2145 [10121 1115 [526) 1485 [701 ] 1900 [897] 2080 [9821 1030 [486] 1425 [673] 1815 [857] 1995 (942] NtI ES: 'Designates "R" for U.S. models, and "A" for Canadian n odels. • •'Not to be used as a heating speed. Data compiled with factory filters installed. [ ] Designates Metric Conversions Z �gg W 7U .0 0 ww N J W0 2 W Z � h- 0 W 2 U o 0 1- W W U. O lll _ O Z DEPARTMENTS: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved 11 Approved with Conditions CORRECTION DETERMINATION: Approved El Approved with Conditions ri REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: m02 -036 DATE: 02 -20 -02 PROJECT NAME: ,LOWER JUNCTION - LOT 5 SITE ADDRESS: XXX SOUTH 150 TH STREET Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Buildin Division L - I Fire Prevention r7 Planning Division 3 - I'mo Public Works n Structural ri Permit Coordinator DUE DATE: 02-21-02 Incomplete n Not Applicable No further Review Required DUE DATE 03 -21 -02 n Comments: DATE: Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE Not Approved (attach comments) ri DATE: REGI STERED AS PROVIDED BY LAW AS ' CONST CONT GENERAL REGIST : # UP. DATE CCO1 TRYONCL013DH 02/11/2003 EFFECTIVE DATE 03/08/1999 TRYON CONCEPTS LLC PO BOX 148.: RENTON WA . 98057 7 _ Issued 'by DEPARTMENT OF LABOR AND INDUSTRIES •