HomeMy WebLinkAboutPermit M02-044 - COMPAQM02-044
Compaq
3515 S 116 St
Value of Construction:
Type of Fire Protection:
Print Name:
doc: Mech
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 1023049043
Address: 3415 S 116 ST TUKW
Suite No:
Tenant:
Name: COMPAQ
Address: 3415 S 116 ST, TUKWILA, WA
Owner:
Name: BEDFORD PROPERTIES INC
Address: 12720 - GATEWAY DR., SUITE 107
Contact Person:
Name: TERRY COURSE
Address: 899 WEST MAIN ST, AUBURN, WA
Contractor:
Name: IECS INC.
Address: P.O. BOX 19252, SEATTLE, WA
Contractor License No: IECS * * *044QL
DESCRIPTION OF WORK:
INSTALL TWO GAS /AC ROOFTOP UNITS & DUCTWORK. INSTALL 1 AC ONLY ROOFTOP UNIT &
DUCTWORK.
Permit Center Authorized Signature:
$4,800.00 Fees Collected:
Uniform Mechnical Code Edition:
MECHANICAL PERMIT
JI1J(4I t C7? ,kM
Permit Number: MO2 -044
Issue Date: 03/20/2002
Permit Expires On: 09/16/2002
Phone:
Phone: 253 - 939 -9260
Phone: 206 939 -9495
Expiration Date: 11/02/2002
$84.50
1997
Date: 3-d0 "
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
rformance of work. I am authorized to sign and obtain this mechanical permit.
Date: �, -
regulating�pstr
Signat
k)-2
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
MO2 -044
Printed: 03 -20 -2002
DEPA TMENTS:
Buil i 'vision rer
MA' 3 M
Public Works
Please Route
TUES /THURS ROUTING:
PERMIT C�$R
PLAN REVIEW/ INC, LIP
ACTIVITY NUMBER: MO2 -044
DATE: 03 -05 -02
PROJECT NAME: Compaq
SITE ADDRESS: 3415 S 116 St
x Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Is Issued
Structural Review Required
Fire Preve ti n
AIwG 3 . � .o�
Structural ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials:
Planning Division
Permit Coordinator XL
DUE DATE: 03-07-02
Not Applicable C
No further Review Required
REVIEWER'S INITIALS: DATE:
DUE DATE: 04 -04-02
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions g Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials:
Documentshouting slip.doc
2 -28.02
PERMIT COORD COPY
re w
QQ
J U
00
N
W =
J
CO LL
w 0
5/2
I-
z I—
w ui
2 o
U
O
I•-
w w
� F -
z
V=
O
z
ACTIVITY NUMBER: MO2 -044
DATE: 03 -05 -02
PROJECT NAME: Compaq
SITE ADDRESS: 3415 S 116 St
_Original :Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Building Division
Public Works
Please Route
Documents/routing slip.doc
2 -28-02
TUES /THURS ROUTING:
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
Planning Division
Permit Coordinator
C
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03-07-02
Complete & Incomplete ❑ Not Applicable ❑
Comments: C Ne,GL \ 1n50L - kr n ti r t... wGt,he . kar,_s-e_ -- SeP
t.u.i at ■ p e✓tAti F CO2 -01 '- I1 w -e6-1 Lsp wails D (i/
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Structural Review Required ❑ No further Review Requi ed ❑
DATE: 3, D
DUE DATE: 04 -04 -02
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE: 3
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
PERMIT NO.: M O 044
MECHANICAL PERMIT APPLICATIONS
INSPECTIONS
8
2 Pre- construction
50 WSEC Residential
60 WA Ventilation/Indoor AQC
610 Chimney Installation/All Types
700 Framing
1080 Woodstove
1090 Smoke Detector Shut Off
1100 Rough -in Mechanical
1101 Mechanical Equipment/Controls
1102 Mechanical Pip/Duct Insul
1105 Underground Mech Rough -in
1115 Motor Inspection
1400 Fire - Final
1800 Mechanical - Final
❑ 4015 Special -Smoke Control System
CONDITIONS
10001 No changes to plans unless approved by Bldg
Div
10002 Plumbing permits shall be obtained through King
Co
10003 Electrical permits obtained through L & I
10005 All permits, insp records & approved plans
available
10014 Readily accessible access to roof mounted
equipment
10016 Exposed insulation backing material
10019 All construction to be done in conformance
w /approved plans
10027 Validity of Permit
10036 Manufacturers installation instructions required
on site
10041 Ventilation is required for all new rooms &
spaces
10042 Fuel burning appliances
10043 Appliances, which generate.
Water heater shall be anchored....
Additional Conditions:
FEES
TENANT NAME: (NV p- cif
Basic Fee (Y/N)
Supplemental Fee (Y/N)
Plan Check Fee (Y/N)
Furnace/Burner
to 100,000 BTU (qty)
Over 100,000 BTU (qty)
Floor Furnace (qty)
Suspended/Wall/Floor - mounted Heater (qty)
Appliance Vent (qty)
Heating/Refrig/Cooling Unit/System (qty)
Boiler /Compressor
to 3 HP /100,000 BTU (qty)
to 15 HP /500,000 BTU (qty)
to 30 HP /1,000,000 BTU (qty)
to 50 HP /1,750,000 BTU (qty)
over 50 HP /1,750,000 BTU (qty)
Air Handling Unit
to 10,000 cfin (qty)
over 10,000 cfm (qty)
Evaporative Cooler (qty)
Ventilation Fan (qty)
Ventilation System (qty)
Hood (qty)
Incinerator - Domestic (qty)
Incinerator - Comm/Ind (qty)
Other Mechanical Equipment (qty)
Other Mechanical Fee (enter SS)
Add'I Fees - Work w/o Permit (Y/N)
Insp Outside Normal Hours (hrs)
Reinspections (hrs)
Miscellaneous Inspections (hrs)
Add'l Plan Review (hrs)
Plan Reviewer:
Permit Tech:
Date: Q
Date: 3��" L --02-•
J
{
ACTIVITY NUMBER: MO2 -044
PROJECT NAME: Compaq
SITE ADDRESS:
3415 S 116 St
DATE: 03 -05 -02
x Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Building Division
Public Works
Complete ❑
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete n
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route ❑ Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: ✓ 0
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2.28 -02
PLAN REVIEW /ROUTING SLIP
❑ Permit Coordinator ❑
Planning Division
DUE DATE: 03-07 -02
Not Applicable ❑
No further Review Required
DUE DATE: 04 -04 -02
DATE: ? " /'/" 0,2
1-
—1 U
00 0
U w
w
2
grj
Do
1
ZjE
w
W
0
co
0 —
0I—
W W
H -- U.
)
=
O
Z
Project NanWTenanb ' V Kai [ ip.era:
COW%PmG? • O t7t
S Addrsu :
3 4 L $11(o 57, h
Chy 5taWZIp
" LL.V.I.v U-A LA./ A
�rerr . N urben
1 b 4" �'t 043 - O `7
re t'.""a _ � ILA) PA-
�t L ,�► 1� _ S
A wl AN C -1- ' ' hhh-N! 1 , P
w,one, cN 15 3R�1 - 1 00 o
p L
FR o,t.1 Cc7, 9 't 111
fax *:t i
Contratt.n t5. T�'C,
! ""ne �q� - 9S�i`il4aS_ pax e: r� b e�
k 6tyi5 nri xa tA.L , A - V 00 1
Phone. ( 133 i °13°1 -9 455
Street "
A PI W) tA)
City state /Zip:
.. t Pru.aLLO. A) wA
Pi 0: t )
.' 3 `I 3°i -° �l�O
caetnta p«w� ; e�J Co(�t.r2.�c: �� �U°
• 9 pi - L l y 9 5
Sued A - —
OW StadLp
Fax f: i
eU N AUTHORIZED AGENT,
*annum
-- Oete:3_,s 2
F
Prins "`pr R-2
r
! ""ne �q� - 9S�i`il4aS_ pax e: r� b e�
k 6tyi5 nri xa tA.L , A - V 00 1
Ad "" f9 '1 IN r r'''`-'�1✓'✓
I'tAR el •22 64:29PM Wir.WILA MD 'fit
CITY t..• TUKWILA
Permit Coster
6300 Southwater loufavared Suite IOC
Tukwila WA 96108
(206) 431.3670
■14.t i).ti1it , 11 Permit r\;)I)I1(,tlit)11
Application and plans mmf be complete in order 1* be accepted for plan eevlew.
wtieas will not lm accepted &mesh the mail or facsimile.
F. 2.
MECHANICAL PERMIT REVIEW AND APPROVAL R[QUUTeDr (TO of PULED OUT RYAMYLCAN1)
Ossscriptlon of wort: to be done (please be spelt)*
S JS P& tr - t S AG 2007 TAP touJco264
3 $m LL— 1 Ire— OAJL•/ 2oCYF 1 -P %Leer .T ••0 DAL c:1 1e.t_
Curren Copy of Washington Slate DepatVMnt of WW1 and Istdsatties Valid Contnetor'a Licetw. If not awlabk at the time of
sppilatIen, a copy of fhb IOa•• r dI be misdeed before the pennk le based OR Word Form tope, "Affidavit in Uwe of Coatrataor
Neelatreden•.
Sulfate OwienAutlaricsd Apet: If the applicant k other than the owner. rebored ardtiMstrolneer, er contractor licensed by the
State of Washington, a notarieud letter from the property owner Guth ertzing the mpg to :Omit this permit application and oban die
webs wlq be required as pan of this submittal.
I HINNY cgaflit' MAT i HAVE READ AND EXAMINED T74S APPL1CAftON AND KNOW THE SAW 70 11 Pauli UNDEM
"NAM OP ftlRJURV RY7HE L4 WS Of fll S TAT E OF W4 H14GT h(. AND 1 AM AUTHORIZE P 0 AMPLY FOR THIS f[RMA.
Eadration el Pim Rsi • Appltcotions for which no permit is lewd within 160 days following the date of awl' adios shall teplra by
Imitation. The building dicta; may extend the time fur action by the irooticanl fur apoiod not exceeding 110 days span written
mewl by the applicant as defined in Sect ion 114.4 of the Uniform Medtanieal Code kwrent edition). No owliration shall be
extended mom then arse.
Parcel No.: 1023049043
Address: 3415 S 116 ST TUKW
Suite No:
Tenant: COMPAQ
doc: Conditions
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
Permit Number: MO2 -044
Status: ISSUED
Applied Date: 03/05/2002
Issue Date: 03/20/2002
1: ** *BUILDING DEPARTMENT * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by
that agency, including all gas
piping (296- 4722).
4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be
inspected by that agency
(206- 835 - 1111).
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These
documents are to be
maintained and available until final inspection approval is granted.
6: Readily accessible access to roof mounted equipment is required.
7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication
showing the fire performance
rating thereof.
8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as
amended, Uniform Mechanical Code
(1997 Edition), and Washington State Energy Code (1997 Edition).
9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a
permit for, or an approval
of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to
give authority to violate
or cancel the provisions of this code shall be valid.
10: Manufacturers installation instructions required on site for the building inspectors review.
11: ** *FIRE DEPARTMENT CONDITIONS * **
12: * ** SPRINKLER SYSTEMS * ** - UFC ARTICLE 10 - NFPA 13
13: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under
overhangs greater than four feet
wide. (NFPA 13- 4- 5.5.3.1)
14: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or
adding sprinkler heads.
15: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems.
(NFPA 72 -1- 5.5.4)
16: Local U.L. central station supervision is required. (City Ordinance #1900)
17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900)
18: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention
Bureau. No work shall commence
until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3)
19: Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance
#1900)
20: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire
Alarm" or "Fire Alarm Control ".
(City Ordinance #1900)
MO2 -044 Printed: 03 -20 -2002
o QQ : �
WV
V
N ca
aa
W
rn
u.
�.
a
O
Lu
V O
O N'
O t–
w
1 -
O
.Z
V Z .
p I-
z
The granting of this permit does note
regulating construction or -tbe :p rfor
Signature:
Print Name:
doc: Conditions
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
21: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped
with an automatic shutoff.
Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the
main supply -air duct served
by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in
accordance with the
manufacturer's installation instructions. (UMC 608)
22: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2))
23: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900)
24: In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to
provide notification of fire at
that location. (NFPA 1 -5.6)
25: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for
access shall be placed in the
lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. (City Ordinance #1900).
26: Duct detectors shall send a supervisory signal only upon activation.
27: ** *ELECTRICAL * ** UFC Article 85 - NPFA 70 - NEC
28: An aisle to and working space shall be provided for each electrical panel. An aisle width not Tess than 24 inches shall provide
access to the panel and 30
inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c))
29: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22)
30: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70)
31: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such
condition or violation.
32: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-
4407.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
e to give authority to violate or cancel the provision of any other work or local laws
MO2 -044
Date: 3 ? v-
Printed: 03 -20 -2002
W
00
W
u.
uJ
w
I- 0
Z H
uj
0 N
o
w W.
0
u' O
W Z
U2
O~
z
Payee: GEORGE HUMPHREY
TRANSACTION LIST:
doc: Receipt
Amount
Payment Check 1573
ACCOUNT ITEM LIST:
Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
Type
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
RECEIPT
Parcel No.: 1023049043 Permit Number: MO2 -044
Address: 3415 S 116 ST TUKW Status: APPROVED
Suite No: Applied Date: 03/05/2002
Applicant: COMPAQ Issue Date:
Receipt No.: R020000388 Payment Amount: 84.50
Initials: KAS Payment Date: 03/20/2002 01:39 PM
User ID: 1684 Balance: $0.00
Method Description
84.50
Description Account Code
000/322.100 67.60
000/345.830 16.90
Total: 84.50
03/21 TOTAL
A1_
Printed: 03 -20 -2002
Project:/ —�J�
Type of Inspection: •
de
Address:
r � /fi
lld
ate cae:
Db t t - M —o
Special instructions:
Date wanted:', '.
-^').•�
. I 4 ,,
Requester:.
Phone:
r •
4
Approved per applicable codes.
'
1 COMMENTS:
Inspector:
211
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permi
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
Corrections .. required prior to approval.
1 oz- o 4 /
PERMIT NO.
(206)431 -3670
Ej $47.00 REINSPECTION FE4 EQUIRED. Prior to 'inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. CaII to schedule'reinspection.
:;Date: 3
Receipt No:
'Date:
Pryjp
Type o nspection• .,.
nrr =
A r es
�5 S , (l - �e
' .
Date called;.'
2v 02
Special instructions:
Date wanted .
Req ter:'.... [[
P s 3 '3 : r I q5
PERMIT NO.
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
4 6300 Southcenter Blvd, #100, Tukwila, WA 98188
pproved per applicable codes.
COMMENTS:
.( /) s4/1 y 6 - ,s.� n :s- � p s...
v r /l?.11�/ (- /7/ S 4/i
,Qs 7z-op
6 01-2 Td )114 / n t/7/.?/:! .c'./ - -/ o'1-r1
��•s�P(��..r�rj l7 .et- N 7, J Tt/ e
— i ;t1 �e. ccJJ
Ins'ector
.00 REINSPECTION I E REQUIRED.
t 6300 Southcenter BIv ., Suite 100. Ca
eceipt No:
Date: "
3 /---o a.._
rior to inspection, fee must be paid
1 to schedule reinspection.
Date:
L`.i:•:a.11tlaLa:..�)f.:..�. .7`. 1.8�? ., _ ,:
INSPECTION RECORD
Retain a copy with permit
(206)431 -3670
Corrections - required prior to approval.
Exhibit A -2
SITE PLAN OF BUILDING
FILE. COPY
•vr, -.r)' Ir.:!n are
t al. -. r•r .n . 1 ..
CITY Of TINOLA
APPROVED
MAR 1 9 2002
i4SU I,;.0
DNG DIVISION
,,,,„RECEIVED KILA
MAR - 5 2002
PERMIT CENTER
Mod - oLN
w
MR 04 2002 09:25 FR
Alitsiakmilitwasteasuilisimiiiimulatamaalikagrflawitaistaa'wwwitadicia
Main Comm /Server Room
Voice Systems Definity Phone Service
All Equipment Cabinets PBX equipment 120 1 60 12
WAN Systems
LAN Hubs
ATT System Management Mist Syst. Mgt. Devices
CPU G3MA, etc, 120 1 60 5
Monitors VDU's 120 1 60 3
Printers Output devices 120 1 60 4
PBX UPS 120 1 60 4.5
maavanoammtiv"- waszTE mac
Compaq S450 48 Port 10/100 Switch
CISCO 2514 Router Backbone Connectivity 120 1 60 2
SMTs System Mgt. 120 1 60 2
CSU & DSU Channel/Digital Serv. Unit 120 1 60 1
Compaq Rack 3000 UPS
Offitlit4 -1..MalkelE
Mik,12StMiNittalinaliriME
TO 912539399260 F.02
LAN connectivity 120 1 60 1.0
LAN connectivity 120 1 60 0.5
RECEIVED
L'ITY OF Mimi
LA
MAR - 5 2002
PERMIT CENTER
M oki
MAr
re
C) (0 8
ww
uj
L u 0
g
u- <
11J w
2
D
u)
0 —
0
ILI u j
9u,
t=
0 1—
Z
.4 2002
MHK i4 002 09:25 FR
//14rc4
1.44 1 20 1.44 4,910 4,910 Yes varies
1
0.60 0 20 0.00 2,046 0 yes NEMA 5-20R
1
0,36 1 20 036 1,228 1,22$ yes NEMA 5-20R
0.48 1 20 0.48 1,637 1,637 yes NEMA 5-20R
0.54 1 20 0.54 1,841 1,841 no NEMA L5-15R
0.24 1 20 0.24 818 818 yes NEMA 5-20R
0.24 1 20 0.24 818 818 yes NEMA 5-20R
0.1.2 1 20 0.12 409 409 yes NEMA 5-20R
0.12 2 20 0.24 409 818 yes NEMA 5-15R
0.06 1 20 0.06 205 205 no NEMA L5-30R
grorsigotuoimaimeaunammusaara
TO 912539399260 P.O/03
** TOTAL PAGE.03 *w
m o o
Feb -ZS -U:4 U4:4t7M
Date:
I
JOB DATA:
BUYER:
UNIT NUMBER: f - W _C..\ GP -3
PERFORMANCE DA IA CERTIFIED BY:
• Standard um: year limited warranty for hod) TUGS and
10C/X.
• 10 year %Yarrtnr; on the SOCi X compressor.
• 5 ; ear wet rent: on the 50CS oumpressor.
• Units certified and listed by Ut . and e -UL. Units are rated
in accordance with ARI Standard 210.
• Low sound ratings.
• ilnic.4 are pre-wired, prc-piped, and pre - charged for mini -
m;:rrt mstaltiitiur. expense.
• 1 SEER coo hog efficiency, on 50GX; with Energy StartlC'
Itet:oaninnn.
• Compressor vibration icct ation pru% ides quieteroperation.
• easily Convertctl for :low operation with included
horizontal dues covers.
• Cabinets are etinsw.teteti of heavy - dory, phttsphined. line
coated pre - painted steel capable ofwithst:nding 500 hoots in
salt spray.
Supersedes:
COMPAQ COMPUTER
SEATTLE MECHANICAL
Unit Operating Weight 254 Ih (unit);
(curb)
COOLTN¢;
Nr. Total Capacity 16.000 Bnth
Net Sensible Capacity 12,30P :huh
Compressor Power input ; x., kW O l t o5 'r
Outdoor-Air Tcrnpernture
Indoor Ertteri:tc- Air d4,. 8O_'1= wh _
Sea. t Energy Efficiency Katie 1Q.D
I.: — 600 h:tt. Static Pressjte _45 in. wg
Indoor Fin Motor 1!4 Hp Rpm Bhp
PERFORMANCE DATA
85 .1b HEATINC
87
US
LOCATION:
5o0501e -0S0/500X02$o60
SIngle•Packapa
Electric Cooling Units
SWIM p 0,
MODEL NUMBER:
FEATURES
' F
TUKWILA WA.
CARRIER $
50G -3
1 DATE:
50GS /5(1CX unit are rttf•cnruar :d, r reran: euultng units de-
signed for easy installation and maintenance and dependable
performance. All units have th,eharge upertnes for either Itor-
icuntul CT duwnfluw configurancm. and all have low aunnd
levels. Units arc intended for outdoor installation and may be
located on a rooftop, or a ground -level concrete slab. or direct-
ly un the ground if laca: codes pc.mit
• Eas•to•5crvicc cahi ::eL5 with single -panel aeecssibitiry.
• Direct -Drive multi - speed, permcnent split capacitor (PSC)
indoor motor Is standard.
• Direct - drive, PSC outdoor tan motor.
• C :nits constructed t;t ahimimirn tins bonded to copper
tubes.
• Wire grille provides udditiunri protection for the coil.
• Environtf'fr composite rust-proof unit hose pane
• Sloped drain pan minintrita standing water is the unit
• Refrigerant service connections make checking operating
pressures easier.
• ('upper & pre - coated fin ceti5 arc available from the fse-
; err by spacial order, for u.c in curTusive envir:mmcnts.
• Three -phase units availulagY Of TUKWILA
APPROVED
Power Input To Unit
Indoor Operating Temp
Outdoor -Air - Temp -- -
Electric Capacity Required
50031503X
0
MAR - 5 2002
Ravi.
02/25! 02
MAR 1 9 2002
AS NO (EU
tt11 LDNG O1VtglON
IT CENTER
kW
70 .'•t dh
24 °F (Winter Design)
n Btuh
KW Heater Selected
RECEIVED
CITY OF TUKWILA
Fab -25 -uz u4: l:�r
JOB NAME:
BUYER.
UNIT NUMBER:
COMPAQ COMPUTER
SEATTLE MECHANICAL
u- 1,0 GP -2
PERFORMANCE DATA CERTIFIED BY:
48t,S Packaged Gas Heat / Electric Coop units
LOCATION:
CONTACT:
TUKWILA, WA.
TERRY
MODEL: 48(35.0300403
AIREFCO, INC. / SALESPERSON
DATE: { 2/25/02
DESCRIPTION
High efficiency, self contained gas heat! electric cool units designed for easy installation,
maintenance and dependable performance. All units can be installed in horizontal or vertical air flow
configurations.
STANDARD FEATURES
Rated in accordance with ARE Standard No. 210 Direct drive , mu:tt -speed PSC blower motor
Low sound ratings Integrated gas control ooard
Certified and listed by IJL and UL, Canada Vibration isolation for quieter operation
Units are pre - wirec, pre -piped and pre- charged Composite rust -areof basepar
Direct spark ignition Sloped drain pan minimizes standing water
Corrosion resistant heat exchangers LIMITED WARRANTY
Heat pump style base pan One (1) year parts only on aft parts
Electric ground lug Additional four (4) year on compressor (NO LABOR)
Operating Weight:
COOLING
Total Capacity:
Sensible Capacity:
Power input to unit 3.03 KW
Outdoor DB: 95 (F)
Entering Indoor OS: 80 (F)
Entering Indoor W6 67 (F)
SEER: 10
Unit Power Supply:
MCA: 20.8
280 LBS Curb:
28,800 (Btuh)
20,700 (Btuh)
Unit CFM:
1,000
ELECTRICAL DATA
208/230 VOLTS,
30
MOCP:
ACCESSORIES
Low Ambient Control
Winter Start Control
High Pressure Switci
Low Pressure Switch
Crankcase Heater
85 LES
PERFORMANCE DATA
HEATING
Input:
Output:
AFUE:
Outdoor DB:
Indoor O6:
1 PH,
40.000 (Stun)
32.040 (Btuh)
30.1%
95 (F)
80 (F)
ESP:
TXV
Economizer
X Curb
Filter rack
Manuai air de
50 HZ
0.5 WC
RECEIVED
CITY OF TUKWILA
MAR -- 5 2002
PERMIT CENTER
tfi ,.i•±..4ar.'::fly�'.'•:L.. "A;;' "�i`�. >�h: 1e.:414'44:r4)
re iu
0
u) O
NW
F
W
c
Z F
uj
D p
O co
0 I--
W W
U
LL Z
'
V =
O I.
Z
• Fab -2b -OZ 03:b4F+
JOB NAME:
BUYER:
UNiT NUMBER:
Znt 11
PERFORMANCE DATA CERTIFIED BY:
Operating Weight:
COOUNG
Total Capacity:
Sensible Capacity:
Power input to unit
Outdoor DB:
Entering Indoor DB:
Entering Indoor WB
SEER:
10
Unit Power Supply:
MCA: 31.1
60,000 (Btuh)
43.900 (Btuh)
6.74 KW
95 (F)
80 (F)
67 (F)
44905 Packaged Gas Heat / Electric Cool Units
LOCATION:
CONTACT:
MODEL #:
AIREFCO, INC. 1 SALESPERSON
DESCRIPTION
High efficiency, self contained as heat / electric cool units designed for easy installation,
maintenance and dependable performance. All units can be installed in norizcntal or vertical alr flow
configLrations.
STANDARD FEATURES
Rated in accordance. with ARE Standard No. 210 Direct drive , mt:Iti -speed PSC blower motor
Law sound ratings In.egrateo gas control board
Certified and listed by UL and tJL, Canada Vibration Isolation for quieter operation
Units are pre - wired, pre -piped and pre - charged Composite rust-proof basepan
Direct spark ignition Sloped drain pan minimizes standing water
Corrosion resistant heat exchangers LIMITED WARRANTY
Heat rump style base pan One (I) year parts only on all parts
Electric ground lug Additicnai four (4) year on compressor (NO LABOR)
450 LBS Curt::
100 LBS
PERFORMANCE DATA
HEATING
Input:
Output:
AFUE:
Outdoor DB:
Indoor DB:
Unit CFM:
2000
ELECTRICAL DATA
208/230 VOLTS,
3PH,
DATE:
MOCP:
ACCESSORIES
Low Ambient Control
Winter Start Control
High Pressure Switch )( Curb
Low Pressure Switch Filter race;
Crankcase Floater Manual airda
TXV
Economizer
48GS - 0600905
90,00G (Btuh)
70,47C (Btuhi
76.6
95(F)
80 (F)
ESP:
60 HZ
0.5 WC
45 RECEIVED
CITY OF TUKWILA
MAR — 5 2002
PERMIT CENTER
r v�
Mu a-ogq
Sent By: HUDSON & ASSOCIATES;
( 22 )
DIAPHRAGM
NAILING
SCHEDULE
<22' -0 "›.
<22' -0 "Y
24' -6"
5. \CC'- _000.2% 19 \20!9.;2 CWG
R.D
6 }
� b
.1. 4 " ,
. VIDNAL' C
-3 1/211
TYP.0 GRID E
2a -6
0
2063246248;
X
D -6
y \�
24' -6"
R
filar -1.02 10:08; Page 215
R.D
24' -6"
' 13 — 6 "
4x8 SKYLIGHF —,
TYPICAL
RE:ARCH
1/2` PELICAN
MILL 058
(NO-E 'URNISI F
TI /2' THICKNESS)
4.`‘
tzs
PERMIT CENTER
24
#II 415 LBS
FILE CC1Py
110 -6 rn l
4 x 14
DENSE
® 8' -0
B1J I LD I NG 5
FRA VI I \QYO E D�'' 1�1
U �`..
0 %04C- MAR - 5 2002
F- , Ma,. J 1 08:4W2002
t,ss
r.
M 0 3.- 0 lal
CD Z
C N O
(T ) n o
to 0 1}
O
o
0 3
- LJ
C
(D
m
In
—4
r1
N
N
0
N
#12 x 212" WOOD
SCREW ® 24 "OC
1b LAG SCREW
24 "OC
PENETRATE BEAM
BELOW 4" MIN
UNIT #9 AND #10 WEIGH 280
POUNDS
UNIT #11 WEIGHS 415 POUNDS
i g
EXISTING
2x STIFFENERS
HEAD OFF W /4x6
EXISTING
PURLIN ® 8 OC
EXISTING
GLB
SECTION A
SCALE: 4 1 4" = 1' -0"
#12 TEK SCREW 0
18 "OC ® UNIT TO
CURB
CURB BY MECH.
CONTRACTOR
4x P.T. SLEEPER
RIPPED TO LEVEL
UNIT
4x6 BLOCKING
W /U46 HANGER
EA END
PLACE CURBING
OVER PURLIN
OR PROVIDE 4x6
w /HANGER.
NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN
THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT.
cV
N
1
L
LL
z
n
Q
CO
• Y
w
cn
lL
a;
c_
u,
ri
m
7
NC
X
0
0
O
H
D
m
0)
N
0
CD
N
rn
00
N
O
0
Sert'ay: HUDSON & ASS00IATES; 2063246248; Mar -1 -02 10:09; p age 4/5
RICHARD HUDSON & ASSOCIATES, INC. JOR Cow■ eh 62 Lam. ..'rF-,Z 7. L .
CONSULTING ENGINEERS SMEE7NO 53 0 . 3
1605 12Th AVENUE • SUITE 18
SEATTLE, WASHINGTON 98122 CA'_cULLArea eY 12 4 DPIE 2 ji 1 ! 0-L—
206- 324 -6160 • Fax 206 - 324 -6248
rhudsonOhudsonengineers. com
- ° °r rc r
VN hexig
. L .. .. <..
i 1 i .. r •
O i . 1
rq CflwR.tr1A�, M....? r irrq
`YPIfin S is 1: i
61.0 -Lrm
r
% 4 c? ",.:q-'' z. --�
I OL.)1 Ne"-
„. to 1 l
MO 3.OuIlI
•
Load Express: Load Calculation Software
Load Express: Load Calculation Software
General Job
Job Description: CO ■`tp p tR w 047 iiLt. S
Building Owner.
Program User.
Comments:
Program was Run:
Dataset Name:
Alternative 1 Alt1
Geographical Data
Location:
Weather File:
Latitude:
Elevation:
Seattle, Washington
47 deg
386 ft
3/ 4/02 at 9:56 :43 AM
Untitled
Design Data
Summer Dsn Dry Bulb
Summer Dsn Wet Bull
Winter Design Dry But
Density -Sp Heat Prodt
Design Simulation pen
CITY OF TUKWILAA
APPROVED
MAR 1 9 2002
AS t? f ED
RU1LDING D1V181Of4
80.0 deg F
64.0 deg F
26.0 deg F
1.0988 Btu- min/(hr- ft3 -F)
Apr To Nov
F:1) r‘, noN1
Building Peak Data
Month/Hour: Jul / 15
Cooling Capacity: 63.1 Mbh
Cooling Sensible: 54.1 Mbh
Sensible Heat Ratio (SHI 0.856
Heating Capacity -35.3 Mbh
CIT
RECEIVED
MAR - 5 200Z
PERMIT CENTER
Version 2.2
Title Page
M0).-04q
Load Egress: Load Calculation Software Version 2.2
Zone /Air Handler Descriptions
Alternative - 1 Alt1
Zone /Air Handler Descriptions
Air Handier Type Description
1 CONSTANT AHU1
Zone Type Description
1 Commercial Retail Zone1
Moa'Io
Load Express: Load Calculation Software
Alternative 1 AIt1
General Job Data
Weather Location: Seattle, Washington
Weather Region: Northwest
Clg Simulation Start Month: Apr
CIg Simulation End Month: Nov
Zone Data
Alternative Number: 1
Zone Number: 1
Fir Width: 40 ft
Flo.., (.ength: 48 ft
Ceiling Height: 20 ft
Fir -to -Fir Height: 21 ft
No. of Dup Zones: 1
Ceiling U- Factor: 0.04 Btu /(hr- F -ft2)
Floor Calculation Type: Slab -On -Grade
Floor Loss Coefficient: 0.54 Btu /(hr -F -ft)
Floor Perimeter Length88.00 ft
W H
ft ft
WALL 1 48 x 18
WALL 2 40 x 18
1 40 x 48
Pt. 1 48 x 18
PART 2 40 x 18
Type
8" L.W. Concrete Blk, 6" Ins
8" L.W. Concrete Blk, 6" Ins
Steel Deck, 3.33" Ins
Frame, 0.75" gypsum board
Frame, 0.75" gypsum board
1 -2 Story Office
Building Opening Time: 8 am
Building Closing Time: 6 pm
Building Direction: 0
CIg Sensible SF: 0.00
Cooling Dry Bulb:
Relative Humidity:
Heating Dry Bulb:
People Density:
People Activity:
People Sensible Load:
People Latent Load:
Misc. Equip. Type:
Misc. Equip. Sensible Loac
Misc. Equip. Latent Load:
Misc. Equip. Sensible to Ri
Lighting Intensity:
Lighting Type: Fluorescen
U- Factor Color Percent ( %) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension % Glass Shading Coeff Shadi
Spc Temp Spc Temp
degF deg F
0.14 Light
0.14 Light
0.04 Light
0.39
0.39
0 RA
South
West
North
70 deg F
50 %
70 deg F
200 ft2 /pers
Warehouses
580 Btuh /pers
870 Btuh /pers
Std appliances
2.00 Watt/ft2
0.00 Watt/ft2
0 Btuh
2.00 Watt/ft2
t hung below ceiling
No 0
0
0
0 0
0 0
0
75
85
CIg Latent SF: 0
Htg Sensible SF: 0
People Diversity: 100 %
Bldg Simulation Type: Cooling and Heating
Version
Zone Input D.
Ballast Factor: 1.00
% Percent Light to RA 0 %
Vent Type: General Office Space
Vent Cool Design: , 20.00 cfm /pers
Vent Heat Design: 20.00 cfm /pers
Supply Cool Design: 0 cfm
Supply Heat Design: 0 cfm
Infiltration Type: Pressurized, Tight Construction
Infilt. Cooling Desig 0.00 ach /hr
Infilt. Heating Desig 0.00 ach /hr
Room Exhaust: 0.00 cfm
0
0
0
70
50
0.00
0.00
0.00
0.00
0.00
it Li
UO
coo,
N W.
N LL
O
0 LL a :
co
•
w;`
cy
0 t-.
w
U
U-
Z,
w ;
U W
O '
1
: Load Exiireek Load Calculation Software
Air Handler Input
Alternative 1
( Air Handler 1
Fan Configuration: Draw
Fan & Motor Efficiency: 56.00 %
Cooling Supply Air Temp: 55.00 deg F
Heating Supply Air Temp: 0.00 deg F
Minimum Relative Humidity: 50 %
Supply Fan Static Pressure: 2.50 in H2O
Return Fan Static Pressure: 2.00 in H2O
CONSTANT AHU1
Supply Duct Location:
Supply Duct Insulation:
Supply Duct Temp Rise:
Retum Duct Insulation:
Retum Duct Temp Rise:
Terminal Type:
Total Cool Airflow:
Total Heat Airflow:
Zone(s) Connected:
Retum Air
No Duct Insulation
1.0 deg F TD
No Duct Insulation
2.0 deg F TD
CONSTANT
0 cfm
0 cfm
1
verston t.t
Air Handler Input
Load Express: Load Calculation Software
Alternative 1
Design Cooling:
Airflow (dm) Cooling Cooling Coil
Total Outside % O.A. Total Sensible S.H.R. Entering Leaving
Air Handler #/Type Btuh Btuh DB WB DB WB
BLDG BLOCK 63,134.30 54,053.80 0.86
BLDG PEAK 63,134.30 54,053.80 0.86
1 CONSTANT 2,314.16 192.00 8.30 63,134.30 54,053.80 0.86 73.86 60.57 52.37 50.73
,) Building Peak Load Components
MolHr:
Bldg 7/15
Air Hand 1 7/15
Zone 1 7/15
Solar
Cooling (Btuh) Heating (Btuh)
versio2.2
Peak Load Information
ft2lton dm/ton cfm/ft2 Total
tons
364.94 5.3
364.94 5.3
364.94 439.9 1.2 5.3
Cond Internal OA+Inf Misc Total Cond OA +Inf Misc Total
8,704.6 37,220.9 2,838.2 14,370.7 63,134.3 - 20,448.0 - 9,282.8 - 5,610.5 - 35,341.3
8,704.6 37,220.9 2,838.2 14,370.7 63,134.3 - 20,448.0 - 9,282.8 - 5,610.5 - 35,341.3
8,704.6 37,220.9 2,838.2 14,370.7 63,134.3 - 20,448.0 - 9,282.8 - 5,610.5 - 35,341.3
Load Express: Load Calculation Software Version 2.2
Peak Load Summary - Alternative 1
Zone 1 Zone1
Areas ( ft2 )
Floor:
SlabOnG /ExFIr:
Roof:
Skylight:
Wall:
Wall Glass:
Partition:
1,920.0
88.0
1,920.0
0.0
1,584.0
0.0
1,584.0
Alt1
Space Sens Load
Spc Sens Ld W /Sfty Fctr
Cool Airflow
Cool Airflw W /Sfty Fctor
Cooling Check
Cool Check W /Sfty Fctr
Heat Airflow
Heat Airtlw W /Sfty Fctr
38,142.6 Btuh
38,142.6 Btuh
2,314 cfm
2,314 cfm
1.21 cfm /ft2
1.21 cfm /ft2
2,314 cfm
2,314 cfm
Peak Load Summary
Heating Coil Peak
Outside Air: OADB: 26
Cooling Coil Peak
Peaked at Time: Mo /Hr:
Outside Air: OADB:
WB:
RELHUM:
7 / 15
80
64
41.8%
Moa.0W
Cooling Coil Peak
Heating Coil Peak
Total Load
Sens Load
Percnt of Tot
Peak Tot Sens
Percnt of Tot
( Btuh)
( Btuh )
( %)
( Btuh)
(%)
ENVELOPE LOADS
Solar
Skylight Solar
0.00
0.00
0.00
Glass Solar
0.00
0.00
0.00
Sub Total
0.00
0.00
0.00
0.00
0.00
Conducted
Skylight
0.00
0.00
0.00
Roof
2,131.01
2,131.01
- 3,041.28
Glass
0.00
0.00
0.00
WaII
737.27
737.27
- 9,757.44
Partition
5,836.32
5,836.32
- 5,558.40
SlabOnG /ExFIr
0.00
0.00
- 2,090.88
Sub Total
8,704.59
8,704.59
13.79
- 20,448.00
57.86
INTERNAL LOADS
Lights
11,470.50
11,470.50
0.00
People
13,539.70
5,187.68
0.00
Misc
12,210.70
12,210.70
0.00
Sub Total
37,220.90
28,868.90
58.96
0.00
0.00
MISC LOADS
Outside Air
2,838.17
2,109.74
- 9,282.84
Humidification
0.00
0.00
- 5,610.49
Infiltration
0.00
0.00
0.00
Sup. Fan Heat
4,132.42
4,132.42
0.00
Ret. Fan Heat
3,305.94
3,305.94
0.00
Duct Heat Pkup
7,628.53
7,628.53
0.00
Exhaust Heat
- 696.23
- 696.23
0.00
Sub Total
17,208.80
16,480.40
27.26
- 14,893.30
42.14
OV /UNDR Sizing
0.00
0.00
0.00
Grand Total
63,134.30
54,053.80
- 35,341.30
W /Safety Factor
63,134.30
54,053.80
- 35,341.30
Load Express: Load Calculation Software Version 2.2
Peak Load Summary - Alternative 1
Zone 1 Zone1
Areas ( ft2 )
Floor:
SlabOnG /ExFIr:
Roof:
Skylight:
Wall:
Wall Glass:
Partition:
1,920.0
88.0
1,920.0
0.0
1,584.0
0.0
1,584.0
Alt1
Space Sens Load
Spc Sens Ld W /Sfty Fctr
Cool Airflow
Cool Airflw W /Sfty Fctor
Cooling Check
Cool Check W /Sfty Fctr
Heat Airflow
Heat Airtlw W /Sfty Fctr
38,142.6 Btuh
38,142.6 Btuh
2,314 cfm
2,314 cfm
1.21 cfm /ft2
1.21 cfm /ft2
2,314 cfm
2,314 cfm
Peak Load Summary
Heating Coil Peak
Outside Air: OADB: 26
Cooling Coil Peak
Peaked at Time: Mo /Hr:
Outside Air: OADB:
WB:
RELHUM:
7 / 15
80
64
41.8%
Moa.0W
Load' Express: Load Calculation Software
Load Express: Load Calculation Software
General Job
Job Description:
Building Owner.
Program User:
Comments:
Program was Run:
Dataset Name:
Compaq/ OP( "1
3/ 4/02 at 11:45:05 AM
Untitled
Alternative 1 AIt1
Geographical Data
Location:
Weather File:
Latitude:
Elevation:
Seattle, Washington
47 deg
386 ft
Design Data
Summer Dsn Dry Bulb
Summer Dsn Wet Bull
Winter Design Dry Bull
Density-Sp Heat Prodt
Design Simulation peri
80.0 deg F
64.0 deg F
26.0 deg F
1.0988 Btu- minl(hr -ft3 -F)
Apr To Nov
COPY
CI A �
APPROVED
{U
MAR 1 9 2002
As NO ED
ISUtLDNG DIVISION
Building Peak Data
Month/Hour: Jul / 17
Cooling Capacity: 27.9 Mbh
Cooling Sensible: 25.7 Mbh
Sensible Heat Ratio (SHI 0.922
Heating Capacity -15.7 Mbh
Version 2.2
Title Page
C ITY Y OF E TUK WIt A
MAR — 5 2002
PERMIT CENTER
Load Egress: Load Calculation Software
Version 2.2
Alternative - 1 AIt1
Zone/Air Handler Descriptions
Air Handler Type Description
1 CONSTANT AHU1
Zone Type Description
1 Commercial Retail Zone1
Zone/Air Handler Descriptions
MO'1'1 •
1
Load Express: Load Calculation Software
Alternative 1 AIt1
General Job Data
Weather Location: Seattle, Washington
Weather Region: Northwest
Clg Simulation Start Month: Apr
CIg Simulation End Month: Nov
Zone Data
Altemative Number: 1
Zone Number: 1
FIc+ ^•.Width: 30 ft
Fk _Length: 25 ft
Ceiling Height: 9 ft
Fir -to -Fir Height: 20 ft
No. of Dup Zones: 1
Ceiling U- Factor: 0.00 Btu /(hr- F -ft2)
Floor Calculation Type: Slab -On -Grade
Floor Loss Coefficient: 0.54 Btu /(hr -F -ft)
Floor Perimeter Length40.00 ft
WALL 1 17 x 9
GLASS 1 11 x 6
Rc^ ^'q 1 30 x 25
P/ 1 1 112 x 9
! r
W H Type
ft ft
Face Brick, 6" L.W. Concrete, 6" Ins
Single Coated 1/2 in.
Steel Deck, 3.33" Ins
Frame, 0.75" gypsum board
1 -2 Story Office
Budding Opening Time: 8 am
Building Closing Time: 6 pm
Building Direction: 0
CIg Sensible SF: 0.00
Cooling Dry Bulb:
Relative Humidity:
Heating Dry Bulb:
People Density:
People Activity:
People Sensible Load:
People Latent Load:
Misc. Equip. Type:
Misc. Equip. Sensible Loac
Misc. Equip. Latent Load:
Misc. Equip. Sensible to Ri
Lighting Intensity:
Lighting Type: ecessed fluorescent, not vented
U- Factor Color Percent ( %) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension % Glass. Shading Coeff
Spc Temp Spc Temp
deg F deg F
0.14 Ught West
0.90 0 Plenum
0.08 Ught 0 RA North
0.39
72 deg F
50 %
68 deg F
100 ft2 /pers
General Office Space
210 Btuh /pers
255 Btuhlpers
Std appliances
0.50 Watt/ft2
0.00 Watt/ft2
0 Btuh
3.00 Watt/ft2
0
0
Yes 0
0
CIg Latent SF: 0
Htg Sensible SF: 0
People Diversity: 100 %
Bldg Simulation Type: Cooling and Heating
0 0
O 0 Area
O 0
75 70
Version
Zone Input D. iz
Ballast Factor: 1.00
% Percent Light to RA: 0 %
Vent Type: General Office Space
Vent Cool Design: 20.00 cfm /pers
Vent Heat Design: 20.00 cfm /pers
Supply Cool Design: 0 cfm
Supply Heat Design: 0 cfm
Infiltration Type: Pressurized, Tight Construction
Infilt. Cooling Desig 0.00 ach /hr
Infilt. Heating Desig 0.00 ach /hr
Room Exhaust: 0.00 cfm
Shadi
0.00
0.58 No Sh
0.00
0.00
Z
CC u .
�
Load Express: Load Calculation Software versio2.2 0 0
Peak Load Information t0 W = '
N LL
dizra W O
Altemative 1
LL Q '. I li Design Cooling: O ' '
Airflow (dm) Cooling Cooling Coil 3 W'
Total Outside % O.A. Total Sensible S.H.R. Entering Leaving ft2lton cfm/ton cfm/ft2 Total Z o
Air Handler 0/Type Btuh Btuh DB WB DB WB tons 4 OF ',
BLDG BLOCK 27,900.30 25,725.00 0.92 322.58 2.3 W W
BLDG PEAK 27,900.30 25,725.00 0.92 322.58 2.3 M 0
1 CONSTANT 1,097.04 150.00 13.67 27,900.30 25,725.00 0.92 74.22 59.92 52.87 50.76 322.58 471.8 1.5 2.3
N
'O ,
O I--,
Ili W'
Cooling (Btuh) Heating (Btuh) 0
Mo/Hr: Solar Cond Internal OA +Inf Misc Total Cond OA +Inf Misc Total I Z �
Bldg 7/17 6,901.9 3,660.2 11,843.2 1,268.2 4,226.9 27,900.3 - 5,857.2 - 6,922.6 - 2,913.4 - 15,693.2 V - ` .
Air Hand 1 7/17 6,901.9 3,660.2 11,843.2 1,268.2 4,226.9 27,900.3 - 5,857.2 - 6,922.6 - 2,913.4 - 15,693.2 I--
Zone 1 7/17 6,901.9 3,660.2 11,843.2 1,268.2 4,226.9 27,900.3 - 5,857.2 - 6,922.6 - 2,913.4 - 15,693.2 0
) Building Peak Load Components
Load Express: Load Calculation Software Version 2.2
Sensible Load Profile
Sensible Load Profile (Mbh) - Alternative 1 Alt1
Hour
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Alr Hand 1 4 4 3 3 3 3 3 12 14 15 17 18 19 21 24 25 26 25 15 10 8 6 5 5
Bldg 4 4 3 3 3 3 3 12 14 15 17 18 19 21 24 25 26 25 15 10 8 6 5 5
Zone 1 4 4 3 3 3 3 3 12 14 15 17 18 19 21 24 25 26 25 15 10 8 6 5 5
2
U
2 up
w 0
J
lL
N 3 t
Z � .
UJ
3 p;
;p N
w w'
111 Z
V N'!
Load Express: Load Calculation Software Version 2.2
Peak Load Summary
Peak Load Summary - Alternative 1
Air Hand 1 AHU1
Areas ( ft2 )
Floor:
SlabOnG /ExFIr:
Roof:
Skylight:
Wall:
Wall Gass:
Partition:
750.0
40.0
750.0
0.0
87.0
66.0
1,008.0
AIt1
Space Sens Load
Spc Sens Ld W /Sfty Fctr
Cool Airflow
Cool NOW W /Sfty Fctor
Cooling Check
Cool Check W /Sfty Fctr
Heat Airflow
Heat Airflw W /Sfty Fctr
20,492.7 Btuh
20,492.7 Btuh
1,097 cfm
1,097 cfm
1.46 cfm /fit
1.46 cfm /ft2
1,097 cfm
1,097 cfm
Heating Coil Peak
Outside Air: OADB: 26
Cooling Coil Peak
Peaked at Time: Mo /Hr:
Outside Air: OADB:
WB:
RELHUM:
7 / 17
78
62
40.2%
M4 Oqq •
re W
U O ,
y 0
W W
WO
u- <
to
W
Z O:
u) ;
D p
0
0 N
0
WW
u. O.
Ill Z
Cooling Coil Peak
Heating Coil Peak
Total Load
Sens Load
Percnt of Tot
Peak Tot Sens
Percnt of Tot
( Btuh)
( Btuh )
(%)
( Btuh)
( %)
ENVELOPE LOADS
Solar
Skylight Solar
0.00
0.00
0.00
Glass Solar
6,901.93
6,901.93
0.00
Sub Total
6,901.93
6,901.93
24.74
0.00
0.00
Conducted
Skylight
0.00
0.00
0.00
Roof
1,901.87
1,901.87
- 2,520.00
Glass
543.82
543.82
- 2,696.62
Wall
47.20
47.20
- 511.56
Partition
1,167.26
1,167.26
778.18
SlabOnG/ExFlr
0.00
0.00
- 907.20
Sub Total
3,660.15
3,660.15
13.12
- 5,857.21
37.32
INTERNAL LOADS
Lights
7,166.37
7,166.37
0.00
People
3,437.53
1,525.03
0.00
Misc
1,239.27
1,239.27
0.00
Sub Total
11,843.20
9,930.66
42.45
0.00
0.00
MISC LOADS
Outside Air
1,268.16
1,005.42
- 6,922.57
Humidification
0.00
0.00
- 2,913.46
Infiltration
0.00
0.00
0.00
Sup. Fan Heat
1,959.01
1,959.01
0.00
Ret. Fan Heat
1,567.21
1,567.21
0.00
Duct Heat Pkup
964.37
964.37
0.00
Exhaust Heat
- 263.73
- 263.73
0.00
Sub Total
5,495.00
5,232.27
19.70
- 9,836.04
62.68
OV /UNDR Sizing
0.00
0.00
0.00
Grand Total
1
27,900.30
25,725.00
- 15,693.20
W /Safety Factor
27,900.30
25,725.00
- 15,693.20
Load Express: Load Calculation Software Version 2.2
Peak Load Summary
Peak Load Summary - Alternative 1
Air Hand 1 AHU1
Areas ( ft2 )
Floor:
SlabOnG /ExFIr:
Roof:
Skylight:
Wall:
Wall Gass:
Partition:
750.0
40.0
750.0
0.0
87.0
66.0
1,008.0
AIt1
Space Sens Load
Spc Sens Ld W /Sfty Fctr
Cool Airflow
Cool NOW W /Sfty Fctor
Cooling Check
Cool Check W /Sfty Fctr
Heat Airflow
Heat Airflw W /Sfty Fctr
20,492.7 Btuh
20,492.7 Btuh
1,097 cfm
1,097 cfm
1.46 cfm /fit
1.46 cfm /ft2
1,097 cfm
1,097 cfm
Heating Coil Peak
Outside Air: OADB: 26
Cooling Coil Peak
Peaked at Time: Mo /Hr:
Outside Air: OADB:
WB:
RELHUM:
7 / 17
78
62
40.2%
M4 Oqq •
re W
U O ,
y 0
W W
WO
u- <
to
W
Z O:
u) ;
D p
0
0 N
0
WW
u. O.
Ill Z
Load Express: Load Calculation Software Version 2.2
Peak Load Summery
Peak Load Summary - Alternative 1 AIt1
Bldg 1
Areas ( ft2 )
Floor: 750.0
SlabOnG /ExFIr: 40.0
Roof: 750.0
Skylight: 0.0
Wall: 87.0
Wall Glass: 66.0
Partition: 1,008.0
Heating Coil Peak
Outside Air: OADB: 26
Cooling Coil Peak
Peaked at Time: Mo /Hr: 7 / 17
Outside Air: OADB: 78
WB: 62
RELHUM: 40.2%
1
Cooling Coil Peak
Heating Coil Peak
Total Load
Sens Load
Percnt of Tot
Peak Tot Sens
Percnt of Tot
•,
( Btuh)
( Btuh )
( %)
( Btuh)
( %)
ENVELOPE LOADS 1
Solar I
Skylight Solar 1
0.00
0.00
0.00
Glass Solar ■
6,901.93
6,901.93
0.00
Sub Total
6,901.93
6,901.93
24.74
0.00
0.00
Conducted
Skylight
0.00
0.00
0.00
Roof
1,901.87
1,901.87
- 2,520.00
Glass
543.82
543.82
- 2,696.62
Wall
47.20
47.20
- 511.56
Partition
1,167.26
1,167.26
778.18
SlabOnG /ExFIr
0.00
0.00
- 907.20
Sub Total
3,660.15
3,660.15
13.12
- 5,857.21
37.32
INTERNAL LOADS
Lights
7,166.37
7,166.37
0.00
People
3,437.53
1525.03
0.00
Misc
1,239.27
1,239.27
0.00
Sub Total
11,843.20
9,930.66
42.45
0.00
0.00
MISC LOADS
Outside Air
1,268.16
1,005.42
- 6,922.57
Humidification
0.00
0.00
- 2,913.46
Infiltration
0.00
0.00
0.00
Sup. Fan Heat
1,959.01
1,959.01
0.00
Ret. Fan Heat
1,567.21
1,567.21
0.00
Duct Heat Pkup
964.37
964.37
0.00
Exhaust Heat
- 263.73
- 263.73
0.00
Sub Total
5,495.00
5,232.27
19.70
- 9,836.04
62.68
OV /UNDR Sizing
0.00
0.00
0.00
Grand Total
27,900.30
25,725.00
- 15,693.20
W /Safety Factor
27,900.30
25,725.00
- 15,693.20
Load Express: Load Calculation Software Version 2.2
Peak Load Summery
Peak Load Summary - Alternative 1 AIt1
Bldg 1
Areas ( ft2 )
Floor: 750.0
SlabOnG /ExFIr: 40.0
Roof: 750.0
Skylight: 0.0
Wall: 87.0
Wall Glass: 66.0
Partition: 1,008.0
Heating Coil Peak
Outside Air: OADB: 26
Cooling Coil Peak
Peaked at Time: Mo /Hr: 7 / 17
Outside Air: OADB: 78
WB: 62
RELHUM: 40.2%
1
Load Express: Load Calculation Software Version 2.2
Peak Load Summary
Peak Load Summary - Alternative 1
Zone 1 Zone1
Areas ( ft2 )
Floor:
SlabOnG / ExFIr:
Roof:
Skylight:
Wall:
Wall Glass:
Partition:
750.0
40.0
750.0
0.0
87.0
66.0
1,008.0
AIt1
Space Sens Load
Spc Sens Ld W /Sfty Fctr
Cool Airflow
Cool Airflw W /Sfty Fctor
Cooling Check
Cool Check W /Sfty Fctr
Heat Airflow
Heat Airflw W /Sfty Fctr
20,492.7 Btuh
20,492.7 Btuh
1,097 cfm
1,097 cfm
1.46 cfm /ft2
1.46 cfm /ft2
1,097 cfm
1,097 cfm
Heating Coil Peak
Outside Air: OADB: 26
Cooling Coil Peak
Peaked at Time: Mo /Hr: 7 / 17
Outside Air: OADB: 78
WB: 62
RELHUM: 40.2%
M0t' qq
Cooling Coil Peak
Heating Coil Peak
Total Load
( Btuh)
Sens Load Percnt of Tot
( Btuh) ( %)
Peak Tot Sens
( Btuh)
Percnt of Tot
( %)
ENVELOPE LOADS
Solar
Skylight Solar
0.00
0.00
0.00
Glass Solar
6,901.93
6,901.93
0.00
Sub Total
6,901.93
6,901.93
24.74
0.00
0.00
Conducted
Skylight
0.00
0.00
0.00
Roof
1,901.87
1,901.87
- 2,520.00
Gass
543.82
543.82
- 2,696.62
Wall
47.20
47.20
- 511.56
Partition
1,167.26
1,167.26
778.18
SlabOnG /ExFIr
0.00
0.00
- 907.20
Sub Total
1
3,660.15
3,660.15
13.12
- 5,857.21
37.32
INTERNAL LOADS
Lights
7,166.37
7,166.37
0.00
People
3,437.53
1,525.03
0.00
Misc
1,239.27
1,239.27
0.00
Sub Total
11,843.20
9,930.66
42.45
0.00
0.00
MISC LOADS
Outside Air
1,268.16
1,005.42
-6,922.57
Humidification
0.00
0.00
- 2,913.46
Infiltration
0.00
0.00
0.00
Sup. Fan Heat
1,959.01
1,959.01
0.00
Ret. Fan Heat
1,567.21
1,567.21
0.00
Duct Heat Pkup
964.37
964.37
0.00
Exhaust Heat
- 263.73
- 263.73
0.00
Sub Total
1
5,495.00
5,232.27
19.70
- 9,836.04
62.68
OV /UNDR Sizing
0.00
0.00
0.00
Grand Total
27,900.30
25,725.00
- 15,693.20
W /Safety Factor
27,900.30
25,725.00
- 15,693.20
Load Express: Load Calculation Software Version 2.2
Peak Load Summary
Peak Load Summary - Alternative 1
Zone 1 Zone1
Areas ( ft2 )
Floor:
SlabOnG / ExFIr:
Roof:
Skylight:
Wall:
Wall Glass:
Partition:
750.0
40.0
750.0
0.0
87.0
66.0
1,008.0
AIt1
Space Sens Load
Spc Sens Ld W /Sfty Fctr
Cool Airflow
Cool Airflw W /Sfty Fctor
Cooling Check
Cool Check W /Sfty Fctr
Heat Airflow
Heat Airflw W /Sfty Fctr
20,492.7 Btuh
20,492.7 Btuh
1,097 cfm
1,097 cfm
1.46 cfm /ft2
1.46 cfm /ft2
1,097 cfm
1,097 cfm
Heating Coil Peak
Outside Air: OADB: 26
Cooling Coil Peak
Peaked at Time: Mo /Hr: 7 / 17
Outside Air: OADB: 78
WB: 62
RELHUM: 40.2%
M0t' qq
•
F(12:i-IIi.! 11110 1:)/i
... ... -
1)1 1 \ l II\ 11.,k1 (11: 1,AI1( )1 10,
REGISTERED AS PROVIDED BY LAW AS
CONST CONT SPECIALTY
REGIST. # EXP. DATE
CCAACG IECS***044QL 11/20/2002
EFFECTIVE DATE 11/13/1996
IECS INC
PO BOX 19252
SEATTLE WA 98109-125
1
.LLI.
a
0 Q •
Z.. . 0 L
u) a
9 :
5 CV m 711r U) ii.,
ui 0;
4 cz,
ez
t-
ui .2
41112) AO
-la
>
Ili 0 ii.. *It
5 = a.
tu
cillit 1-.4.,:i
zi..._
....c. CC
11J ui
o 2 a
AD -;
.0 1-
• • • ... . . ...._
.. \\ •Ill ut
...: z.
o rzi
z
1\\ 1
Need Current Contractor Registration Card: ❑ Yes No
Need to Enter Contractor Information in Sierra: ❑ Yes No
isi% t��::y:ikiilij's' ;i ?i ?�3?ie;';� •::iw; ±;`.�e: ?•'Ei2.
z
iz
W
I
00
u) 0
co w
J
WO
co d
I-O
z H
UJ W
U�
0 %
(:)
WW
g
u'O
U =
O ff "
z
LEGAL DESCRIPTION
"AY ASSESSOR'S PARCEL NUMBER: 102304 - 9043 -0
DESCRIPTION. NEW PARCELS A,B AND C OF "�-iL urn OF TUKWILA BOUNDARY LINE ADJUSTMENT #89-8-B, AS RECORDED UNDER KING
COUNTY RECORDING # RECORDS OF KING COUNT,
WASHINGTON
COMPAa
3415 S 116TH STREET p
TUKWILA, WA 98168 -1978
GENERAL NOTES
DRAWING INDEX
9NTERI03 ARCHITFr TURF
�PC A !'CCt-tITECTS
� - -� � 13m1 ed Erred Rd.ame.uaww gems
te1425-64142M fax .5.4374230
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL APPLICABLE SAFETY CODES.
2. THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING OWNER /ARCHITECT /ENGINEER HARMLESS FOR INJURY OR DEATH TO PERSONS
OR FOR DAMAGE TO PROPERTY CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES. OR SUBCONTRACTORS.
3. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT HIS OWN EXPENSE.
4. NKLER, MECHANICAL, AND ELECTRICAL ARE DER SEPARATE PERMIT.
5. COCSPRIES: ALL PLUMBING, WORK SHALL CONFORM TO THE APPLICABLE 9 CODES A ORDINANCES. IN CASE OF ANY CONFLICT WHERE THE
METHODS OR STANDARDS OF INSTALLATION OF THE MATERW.S SPECIFlED DO NOT EQUAL. OR EXCEED THE REQUIREMENTS OF THE LAWS OR
65..
GOVE. NOFY LL CONFLICTS.
NAN THAWS OR ORDINANCES SHLL RN TI THE ARCHITECT OF A
ORDI CES, E L A
. STRUCTURAL, PLUMBING, MECHANICAL, ELECTRICAL AND FlRE PRO TECTION DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS.
THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRTTEN REQUEST
'4-0.0 COVER SHEET & GENERAL INFORMATION
�A -3.t DEMOLITION, FLOOR, FINISH, FURNITURE & CEWNG PLANS
IA -9.1 ELEVATIONS. DETAILS &SECTIONS
FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL BE CORRECTED BY THE
CONTRACTOR AT NO EXPENSE TO THE BUILDING OWNER, TENANT, OR ARCHITECT.
7. USE G.W.B. METAL TRIM AT ALL CORNERS AND EDGES. PAINT TO MATCH ADJACENT WALL.
8. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING SPACE CLEAN, WASH ALL WINDOWS AND GLASS, POLISH ALL
HARDWARE. REPLACE AND PATCH AREAS OF CDUNG DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT.
9. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY PERMITS & FEES. EXCEPT THE BUILDING PERMIT WHICH WILL BE PROVIDED BY THE OWNER:
10. CONTRACTOR TO SUBMIT A UST OF PROPOSED PRODUCT SUBMITTALS AND SHOP DRAWINGS TO TENANT FOR APPROVAL
PRIOR TO START OF CONSTRUCTION. MINIMUM SUBMITTALS: CEILING TILE, CASEWORK AND MILLWORK SHOP DRAWINGS, CARPET,
APPLIANCES, LIGHTING, AND ALL FINISH SELECTIONS.
11. ALL PRODUCTS AND MATER S SPECIFIED IN THE DRAWINGS (W/ EXCEPTION TO SPECIFIC FINISH COLORS AND FLOORING) ARE INTENDED TO BE
ON AN ° OR EQUAL" BASIS. ANY PROPOSED SUBSTITUTIONS MUST BE SUBMITTED TO THE TENANT IN WRITING FOR APPROVAL WITHOUT
DELAY OF SCHEDULE
12. FURNITURE SPECIFICATION AND INSTALLATION BY OTHERS.
DIMENSIONS
compA
CUSTOMER
SERVICES
OFFICE
TUKWILA, WASHINGTON
A
JPC
i N
VICINITY MAP Ill
SCALE NTS
r jAAPpI/gST7 l ,^` 7 'I�
T
-
" : -
T'4
�,- Y _ rR. -
'
5112th St W - _
SYMBOLS LEGEND
®' ROOM NUMBER REFERENCE
DOOR TYPE /HARDWARE CONVENTION:
ROOM NUMBER
DOOR TYPE
HARDWARE TYPE
ma
>d
0 STOREFRONT/REUTE CONVENTION
ELEVATION POINT
�'
AIL REFERENCE WALL SECTION
DETAIL
-- FiLE CO'Y
understand that the Won C,ask approvals are
subject to errors and cirissic::s and approval of
plans does not authorize the ns vicIatica and a of any
adopted Code or ordinance. Rers_iP of can -
tractors copy of approved plans acknowledged.
/
By
Da '--> = -��.
Date Z
1. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT
WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY
THE ARCHITECT OF MAY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK.
2. DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLUMNS AND FINISHED FACE OF PARITTONS, UNLESS NOTED OTHERWISE
DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE 70 BE SIX (6) INCHES FROM THE FACE OF THE
WJACENT PARTTION OR CENTERED BETWEEN PARTTONS.
3. DO NOT SCALE DRAWINGS: THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS.
NOTIFY THE ARCHITECT IF DISCREPANCIES ARE FOUND.
4. COORD INATION: THE GENE CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND COORDINATION OF THE WORK
OF ALL TRADES TO ASSURE COMPWWCE WITH THE DRAWINGS.
5. CONSTRUCT WALLS PLUMB AND SQUARE W/ ammo STRUCTURE AND NEW CONSTRUCTION UNLESS NOTED OTHERWISE
FIRE PROTECTION .
Permit No M !2. -f
SEPARATE PERMIT
REQUIRED FOR
CI AEC
,-,Y ELECTRICAL
, pLI PLUMBING
L(v GAS PIPING
CITY OF TUKWILA
BUILDING DIVISION '
4r _*th
G� ��yN�
tYY""
- 9 1 -*
�'r ';` ' , yY�
h5
� 6',,
T'''
�� Slilt Si
S 1"15t11 SL S71At11
S `� 4 _ �'� `:�'"" >x
7 � ti SC '
Siiel
02001 MapQwSt o,m, Inc, 0200 - • n Techwkrgba 1 ) 1
® BUBBLE REFERENCE BUBBLE -
A REVISION REFERENCE
INTERIOR ELEVATION SYMBOL
� >
a... MR. L.G.
_
�9 Eg�
RE V IH BE
C3A 0 SHALL LL BE MADE TO
OF V/ORK WITHOUT PRIOR
G TUKVJILABUILDIN Dlv;'
o as NEW suss
- • - �'' `w T
CODE INFORMATION
APPLCABLE EDITIONS OF BUILDING CODES:
1997 UNIFORM BUILDING CODE
1997 UNIFORM FIRE CODE
7997 UNIFORM MECHANICAL CODE
1997 NATIONAL ELECTRICAL CODE
1997 WASHINGTON STATE ENERGY CODE (WAG 51 -11)
1997 WASHINGTON STATE BARRIER FREE REGULATIONS
FEDERAL GUIDELINES OF THE AMERICANS WITH DISABILITIES ACT
TYPE OF CONSTRUCTION: 111 -N
NUMBER OF STORIES: 1 STORY
� `dp4 C P
Os4� 7 7/73/07
1. IF NECESSARY, PROVIDE ARE PROTECTION AT ALL PENETRATIONS OF Fl. RATED DEMENTS AS REQUIRED BY CODE
CONSTRUCTION
x �O K ° 01 -100 -0454
0 REFERENCE KEY (REFER TO KEY NOTES)
� BREA KUNE SYMBOL
ELECTRICAL LEGEND
- -
.Approvals
° _
8262 a�pyv,
7. COORDINATE CONSTRUCTION SCHEDULING WITH BUILDING REPRESENTATIVE AND AR CHITECT TO ALLOW ONGOING OPERATION
OF THE FACILITY DURING CONSTRUCTION-
2. CONTRACTOR SHALL ZING CONSTRUCTION.
AND VERIFY LOCATIONS OF STRUCTURAL, PLUMBING, MECHANIC.., AND ELECTRICAL ELEMENTS
AND OTHER EXISTING COND.°. PRIOR TO BEGINNING THE WORK.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FIRE TREATED BLOCKING REQUIRED FOR WALL AND CEIUNG MOUNTED ITEMS.
4. ALL NEW CONSTRUCTION SHALL BE STABILIZED G AGAINST LATERAL MOVEMENT IN ACCORDANCE W. THE REQUIREMENTS OF THE LATEST
ADOPTED EDITION OF THE UNIFORM HURD!. CODE MAX DISTANCE ACCEPTABLE BRACES SHALL BE 8'-O".
5. THERE SHALL BE NO EXPOSED PIPE, CONDUITS, DUCTS. VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND
FINISHED, UNLESS NOTE) AS E(POSED ON CONSTRUCTION DRAWINGS.
CONSTRUCTION LEGEND
ilk EXISTING WALL CONSTRUCTION
NEW WALL CONSTRUCTION
_
_= EXISTING CONSTRUCTION TO BE REMOVED
A GRID HEIGHT PARTITION (NON - RATED): 2 -1/2 METAL
STUDS AT 24 O/C WITH ONE LAYER OF 5/8 TYPE 'X'
EACH SIDE TO BOTTOM OF SUSPENDED GEEING
SYSTEM &WIRE SECURITY MESH ABOVE TO STRUCTURE.
WHERE INDICATED INSTALL NON -FACED BATT INSULATION.
REFER TO DETAIL B/0 -9.1 FOR ADDITIONAL INFORMATION.
GRID HEIGHT PARTITION (NON - RATED): 2 -1/2" METAL
E GWB STUDS AT 24" 0/C WITH H ONE LAYER OF 5/8 TYPE 'X'
EACH SIDE TO BOTTOM OF SUSPENDED CD UNG
SYSTEM. REFER TO DETAIL 7/IA -9.7 FOR ADDITIONAL
INFORMATION. SYSTEM.
FULL HEIGHT P40010 N (NON- RATED): 3 -5 /8" METAL [-III
STUDS AT 24" O/C WITH ONE LAYER OF 5/8 TYPE 'X
GWB EACH SIDE TO BOTTOM OF STRUCTURE. REFER
TO DETAIL 9/l -9.1 FOR ADDITIONAL INFORMATION.
NOTE: EXISTI WALLS WITH WALLTYPE Q TO BE BUILT
TO STRUCTURE AND MATCH NEW CONSTRUCTION.
Q
DUPLE( RECEPTACLE
FOURPLIX RECEPTACLE
DEDICATED FOURPLEX RECEPTACLE
. VOICE/DATA/POWER FLOOR AT
P tky
FLUSH FLOOR BOX
®E VOICE /0ATA WALL RECEPTACLE (EXISTING)
Q (2) VOICE/ (2) DATA WALL RECEPTACLE
a 2 VOICE /DATA DROP FOR WORKSTATIONS (ELECTRICAL PANELS).
NUMBER DENOTES QUANTITY OF STATION (4 CAT5E PER
STATION).
O 2 J -BOX FOR ELECTRICAL CONNECTION TO WORKSTATION
(2 CIRCUIT PER STATION)- NUMBER DENOTES NUMBER OF
QIRQDITS.
"' ll CARDREADER LOCATION (PROVIDED BY TENANT)
7 2x4' INDIRECT FLOURESCENT LIGHT FIXTURE
ILLUMINATED EXIT LIGHTING ON BATTERY BACKUP
®
O RECESSED COMPACT FI OURESCENT DOWNLIGHT
L4., HVAC RETURN GRILL
® H440 SUPPLY GRILL
m FIRE SPRINKLER HEAD
$ SINGLE POLE LIGHT SWITCH
c�
T' 3 -WAY LIGHT SWITCH
WALL FINISH REFERENCE KEY (REFER TO FINISH SCHEDULE)
P7
T
FLOOR FINISH REFERENCE KEY (REFER 70 FINISH SCHEDULE)
IIPNFJJJ
h
81 BASE REFERENCE KEY (REFER TO FINISH SCHEDULE)
6. OFFSET STUDS WHERE REQUIRED 50 THAT FINISH. WALL SURFACES WILL BE FWSH.
7. PROVIDE GALVANIC ISOLATION BETWEEN DISSWRAR METALS.
CEILING
NORTH REFERENCE
FECC. NEW 6/S SEMI- RECESSED WALL MOUNTED FIRE EXTINGUISHER CABINET
F E
�. NEW B/S WALL MOUNTED Fl EXTINGUISHER
DRAWING NAME CONVENTION:
INTERIOR ARCHTECTURE
�DRAWING SERIES
( FLOOR NUMBER
I _ ^ .
L
1. CEILING HEIGHTS, WHERE INDICATED. ARE FROM FlNLSHED FLOOR ELEVATION! TO BOLTON OF CEILING GRID OR OTHER FINISH SURFACE
2 SUPPORT DATA - LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRE OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS,
11/20/01 SPACE P.
12/21/01 75% PROGRESS SET
01 /04/02 95% PROGRESS SET
90 DEG. APART AND CONNECTED TO THE MAIN RUNNER WfiF11N 2" OF THE CROSS RUNNER AND N THE STRUCTURE ABOVE AT AN ANGLE
NOT EXCEEDING 45 DEG. FROM THE PLANE OF THE CDLWG. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION,
W. THE FIRST POINT W TIN 4' -0" FROM EACH WALL SEE DETAIL 14/71- 14-9.1.
3. VERTICAL SUPPORTS SHALL BE NO. 8 US. GAUGE WIRE 70 SUPPORT A MAX. 16 SQ. FL OF CDUNG AND SADDLE -TIED AROUND
MAIN RUNNERS, PER CHAPTER 47.1812. OF THE UBC STANDARDS. CROSS RUNNERS ATTACHED TO MAIN RUNNERS BY SADDLE -TYING
WITH ONE STRAND NO. 16 US. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER CHAPTER 47.1812 OF THE UBC STANDARDS.
DISCONTINUOUS ENDS OF CROSS - RUNNERS AND WAN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES
01/15/02 700% CON. ISSUE
01/27/02 CLIENT REVISIONS
02/01/02 CLIENT REVISIONS
FIRE PROTECTON: FULLY SPRINKLERED
OCCUPANCY: AND S7
TENANT IMPROVEMENT AREA 4,929 SF
AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL.
4. CONTRACTOR SHALL INSTALL CEILING TILES ONLY AFTER ALL CABLING AND CEILING PLENUM EQUIPMENT/DUCTWORK HAS BEEN INSTALLED.
FINISHES
1. ALL PAINT AND OTHER APPLIED FINISH ITEMS SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
2. CARPET CONTRACTOR SHALL FURNISH AND INSTALL RUBBER REDUCE. STRIPS AT LOCATIONS WHORE CARPET AND VINYL COMPOSITION TILES
MEET. PROVIDE COLOR SAMPLES TO TENANT FOR APPROVAL
3. FLOOR COVERING IN CLOSETS SHALL BE THE SAME AS THAT OF THE SPACE UNTO WHICH THE CLOSET DOOR OPENS, U.N.O.
4. PREPARE FLOOR PER FLOORING AND CARPET MANUFACTURER'S RECOMMENDATIONS
TO PROVIDE LEVEL AREA FOR FLOORING INSTALLATION AND LEVEL FLOORING TRANSITIONS.
5. CONTRACTOR TO SUBMIT FULL UST OF ALL FINISHES AND PROVIDE SAMPLES TO TENANT FOR APPROVAL
PRIOR TO START OF ANY FINISH. WORK
PLUMBING, MECHANICAL & ELECTRICAL
1132
COVER SHEET
GENERAL
INFORMATION
IMM
1A-0.0
® 2004 R Ar e1.202tc, RAC
/ A M
PROJECT TEAM
Il V
BUILDING OWNER
AMB INSTITUTIONAL .WAN. FUND I, LP
PIER 1, BAY 1
SAN FRANCISCO, CA 94111
PHONE 415- 394 -9000 a =CdYED
FAX: 415- 394 -9001 caT: of TDKWILA
MAR
TENANT PERMIT CENTER
COMPAQ COMPUTER CORP.
1.75 NE 24TH
BELLEVUE, WA 98005
PHONE 425 - 401 -6108
FAX: 425 - 562 -8609
CONTACT: NANCY ANDERSON
INTERIOR ARCHITECT 0(4
JPC ARCHITECTS 0 °'
!T
, PLLC AA �vvY///
13201 BEL -RED ROAD
BELLEVUE. WA 9.305
PHONE (425) 641 -9200
FAX: (425) 637 -8200
CONTACT: CHAR PATTERSON
ARCHITECT OF RECORD: CHAR PAUERSON
GENERAL CONTRACTOR
UNIMARK CONSTRUCTION
1325 4th AVENUE, SUITE 610
SEATTLE, A NUE,
PHONE: 206 - 628 -5110
FAX: 206- 628 -51.
CONTACT: DAVE RAUMA
ELECTRICAL DESIGN - BUILD CONSULTANT
TBD
MECHANICAL DESIGN - BUILD CONSULTANT
TBD
MU2 - O
1 x 8 SUSPENDED FLUORESCENT UGFMNG
N = NEW
E = EXISTING
R = RELOCATED
1. PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGS TO BE SUBMITTED UNDER SEPARATE PERMIT.
2. MECHANICAL & ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE TO MAINTAIN COMPLIANCE WITH APPLICABLE CODES AND STANDARDS
AND OBTAIN ALL NECESSARY PERMITS AND APPROVALS.
3. DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT.
4. CENTER OF ELEC. AND VOICE /DATA OUTLETS LS 0 18° AFT., U.N.O., SPEC!. HEIGHTS ARE NOTED ADJACENT TO OUTLETS.
5. DIMENSIONS TO AND FROM ELECTRICAL OUTLETS SHOULD BE A MAXIMUM OF 6" FROM CENTER OF ELECTRICAL OUTLET
ABBREVIATIONS
AT CO. CONTRACTOR F.H.OHpGHT IN iNNSUIXiTRON O.C. ON CENTER
® CENTERLINE CORK CORRIDOR O.D. OUTSIDE DIAMETER SIN. S MIUR OA OVERALL SHT. SHEET
NUMBER CPT. CARPET FIN. FINISH(ED) ) JAN. JANITOR S.LM. SPECIAL LAMINATED
' SQUARE FEET C.T. CERAMIC TILE FIR. FLOOR JT. JOINT OH. OVERHEAD EDGE
o r DEGREE(S) GTR. CENTER OPRH. OPPOSITE HAND SPEC. SPECIFICATION
A/C AIR CONORIONING FLUOR. FLUORESCENT KIT. KRCHEN OPNG. OPENING SQ. SQUARE
'Au, ACOUSTICAL F. FACE OF STUD (S1 KF�_ KICKPLATE OAP. OPPOSITE S.STL STAINLESS STEEL
AC.T. ACOUSTIC TILE DEMO. DEMOLMON F.O.C. FACE OF CONC DEN. DETAIL LAM. LAMINATE(D) P.B. PANIC BAR STD. STANDARD
O.F. FACE OF FINISH STL STEEL
ADD. ADDENDUM L H . L. LEFT HAEFT HA ND P -LAM P.BD. PARTICLE BOARD
D.F. DRINKING FOUNTAIN
PUR FT. FOOT // FEET FURRING L.H STORY STORAGE
ADJ. ADJACENT . FURfR PLASTIC LAMINATE STRUCT. STRUCTURAL
.US. ADJUSTABLE
FLOOR DIM. DIMENSION T.E. TENANT'S EXPENSE PR. PAIR PLYWOOD SUSP, SUSPENDED
A.F.F. ABOVE FINISH DIAL DIAMETER r"'' R FUTURE / L. LENGTH /LONG PLWD. LL. 0 BY LANULORO AT PAIL P401 T.B. TOWEL BAR
DN. DOWN ITN. FARTTON T.C. TERRA COTTA
DR. DOOR GA GAUGE TEL TELEPHONE
ALT. ALTERNATE DWG. DRAWING G.B. GRAB BAR LT- LIGHT Q.T. QUARRY TILE TEMP. TEMPERED
A RCH. APPROXIMATE
ARCH. ARCHITECT DWI. DRAWER G.C. GENERAL LVR. LOUVER TERN. TERRAZZO
CONTRACTOR TAD. RADIUS T THIC 0808)
BD. BOARD MAX. MAXIMUM R.B. RESILIENT BASE THRESH. THREESSHOLD
BET. BETWEEN E FAST GEM- GEN ERAL M.C. MEDICINE CABINET R.D. ROOF DRAIN TKBD. TACKBOARD
BLDG. BUILDING EA. EACH GL GLASS {GLAZING MECH. MECHANICAL R.T. RESILIENT TILE T.L. TWIST LOCK
BIJC. BLOCK EL' ELEVATION G.W.B. GYPSUM WALL MEMB. MEMBRANE REF. REFERENCE T.V. TELEVISION
D OT. BLOCKING ELEC. ELECTRICAL BOARD MET. METAL REEL REFLECTED TYP. TYPICAL
DOT. BOTTOM
B/S BUILDING STANDARD ELEV. ELEVATOR GYP- �P�M
M ENCLOSE(URE) MFR. R. MEZZANINE REFRY REFRIGERATOR MANUFACTURE(R) REG. REGISTER UNFlN. UNFINISHED
E
EQ. EQUAL MIN. MINIMUM ftDNF. REINFORCING U.N.O. UNLESS NOTED
EQUIP. EQUIPMENT H.C. HOLLOW CORE MISC. MISCELLANEOUS REQ. REQUIRED OTHERWISE
CAB. CABINET EST. ESTIMATE HD. HEAD MID. MOUNTED REV. REVISION VCT VINYL COMP. TILE
CET. CERAMIC DR EXHAUST HDCP HANDICAPPED MULL MULLION R.H. RIGHT HAND VEIN. VENEER
CHAMP. CHAMFER EXIST. EXISTING HER. HEADER RM. ROOM VERT. VERTICAL
C LG. CIRCLE EXT.. EXPANSION H .M. HARDWARE N. NORTH R.O. ROUGH OPENING VEST. VESTIBULE
CLG. CEILING EXT. EXTERIOR H.M. HOLLOW METAL N.F.S. NON FROST SUSCEPTIBLE VFY. VERIFY
CAR. CLEAR(ANCE) HOER. HORIZONTAL N.I.C. NOT IN CONTRACT 5: SOUTH V.W.C. VINYL WALL
COL V. COUNTER F.E. FIRE EXTNGUISHFR NO NUMBER S.C. SOLID CORE COVERING
COL COLUMN
CONC. CONCRETE F.EC. FIRE EXTINGUISHER HR. HOUR NOM NOMINAL S.C.D. SEAT COVE W. WEST/WIDE
N.T.S. NOT TO SCALE DIS PENSER A y/ Aye
CON. CON! CONSTRUCTION N H.VAC. V L SEAL SEALANT Wb 0 W OOD
W WITHOUT
AIR CONDITONIIIG SH. SHF.F WEIGHT
SECT. SECTION W.T. WAINSCOT
TO CENTER OF TELEPHONE OUTLET.
6. DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION DRAWINGS SHOULD BE CALLED TO THE ATTENTION OF JPC ARCHITECTS.
CASEWORK AND MILLWORK NOTES
1. ALL MILLWORK AND CASEWORK SPECIFIED ON THESE DRAWINGS SHALL BE FURNISHED AND INSTALLED BY THE MILLWORK
CONTRACTOR UNLESS OTHERWISE NOTED.
2. MILLWORK CONTRACTOR SHALL BE RESPONSIBLE FOR FINISHING ALL MILLWORK AND CASEWORK IN HIS SHOP. DO NOT FIELD FINISH.
3. MILLWORK CONTRACTOR SHALL SUBMIT THREE (3) FINISH SAMPLES, 6 MINIMUM IN SIZE, OF EACH FINISH SPECIFlED, FOR TENANT'S
APPROVAL PRIOR TO FABRICATION.
4. MILLWORK CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND SPECIFICATIONS FOR TENANT'S AND ARCHITECT'S APPROVAL QRIOR TO FABRICATION.
JPC ARCHITECTS RESERVES THE RIGHT 70 REJECT ANY MILLWORK ITEMS THAT HAVE BEEN FABRICATED WITHOUT APPROVED SHOP DRAWINGS.
SHOP DRAWINGS MUST BE CLEAR AND CONTAIN ALL DIMENSIONS, CONNECTIONS, ELEVATIONS, EXISTING SITE CONDITIONS, SECTIONS,
HARDWARE, SEAM LOCATIONS, AND ALL OTHER PERTNANT DATA
5. ALL MATERIALS AND WORKMANSHIP MUST BE EQUAL IN ALL RESPECTS TO THE STANDARDS SET FORTH IN THE ARCHITECTURAL WOODWORKING
QUALITY STANDARDS AND ARCHITECTURAL WOODWORKING INSTITUTE (ATM.) MOST CURRENT EDITION PUBLISHED BY THE &W.I. AND THE
STANDARDS SET BY THE PROJECT TEAM.
6. PLYWOOD SHALL BEAR THE GRADE AND TRADEMARK IDENTIFICATION OF THE AMERICAN PLYWOOD ASSOCIATION (A.PA).
7. PARTICLEBOARD BACKING SHALL BE PERMITTED IN AREAS OF THE CASEWORK THAT ARE NOT VISIBLE.
S. ENEERS WITHIN PANEL FA SHALL B ONE PIECE ITCHES HOWEVER, SHOULD JOINE REQUIRED, THEY SHALL BE END MATCHE
AN D /OR SUP MATCHED AS A CES PPROVED BY JP C ARCHTECTS. FL SEAMS MUST BE PLACED IN EQU AL B INCREMENlTS AND CENTERED ON ADJACENT D
ELEMENTS.
9, SUBMIT SAMPLES TO THE ARCHITECT FOR APPROVAL TO SHOW GRAIN VARIATION RANGE PRIOR TO PROCEEDING.
10. PROVIDE CUT -OUTS IN MILLWORK AS REQUIRED FOR ALL EECTRICAL AND PLUMBING TENTS. VERIFY ALL REQUIREMENTS PRIOR TO FABRICATION.
11. FIT AND SECURE CABINET HARDWARE PER MANUFACTURER'S PRINTED INSTRUCTIONS. EXERCISE CAUTION NOT TO MAR OR INJURE SURFACES.
REPAIR ANY AND ALL DAMAGED SURFACES TO LIKE -NEW CONDITION AS APPROVED BY TENANT.
12. ALL MILLWORK ELECTRICAL MATERIAL, WORKMANSHIP, & INSTALLATIONS SHALL BE IN CONFORMANCE WITH APPLICABLE LOCAL, STATE & NATIONAL
ORDINANCES AND CODES. ALL MATERIAL AND FlXTUR(S TO BE U.L APPROVED.
13. GENERAL CONTRACTOR TO FURNISH ALL NECESSARY 18 GAGE METAL STRAPPING FORA COMPLETE AND SECURE INSTALLATION.
- MECHANICAL PLAN c ,, D ,
Scale: 1/8 " =1' -0"
19 FURNITURE PLAN
Scale: i/8 ° =1' -0
OD FINISH PLAN
Scale: 1/8 " =1-0"
O FLOOR PLAN c - D
Scale: 7/8 " =1' -0
I I �rl
� iiLLf.
gMBUIMININIMEN
l►lm.Sg1UA• ®1.
IMMEMMOKM
IIIIMBaffal
•... _ TITAN I
1
C1 I
C2 ACCENT ARPET INTERFACE
PATTERN: C 867 MFG: GRAD
COLOR: 168617 GRAY
LOCATION: AS NOTED ON PLAN
1 C3 I
VCT FLOORING
V7
I V
I v3
V4
V5
BASE
NOTE
USE STRAIGHT BASE IN CONTINUOUS ROLLS FOR
ALL CARPETED AREAS. USE COVE BASE FOR
ALL HARD SURFACE AREAS.
MFG: ARMSTRONG
COLOR: 61 GRAPHITE GRAY
SIZE 4" HIGH
LOCATION: BASE THROUGHOUT U.N.O.
CARPET
GENERAL CARPET MFG: INTERFACE
PATTERN: 19E1002500
COLOR: 169820
LOCATION: FLOORING THROUGHOUT U.N.O.
MFG: INTERFACE
PATTERN: 16244040
COLOR: 4514 AMETHYST
LOCATION: ACCENT CARPET AS
NOTED ON PLAN
MFG: ARMSTRONG
STYLE: EXCELON (SOT)
COLOR: 51950 MARBLE BEIGE
SIZE 12" x 12"
LOCATION: AS NOTED ON FINISH PLAN
MFG: ARMSTRONG
STYLE: STANDARD EXCELON
COLOR: 51809 DESERT BEIGE
SIZE: 12" x 12"
MFG: ARMSTRONG
STYLE: STANDARD EXCELON
COLOR: 51805 CAMEL BEIGE
SIZE: 6" X 6"
MFG: ARMSTRONG
STYLE: STANDARD EXCELON
COLOR: 51910 CLASSIC BLACK
SIZE: 6" x 6"
LOCATION: AS NOTED ON FINISH PLAN
MFG: ARMSTRONG
STYLE: STANDARD EXCELON
COLOR: 51934 LAV. SHADOW
SIZE: 6" x 6"
Pi
AEI
11111111k N I'
e c
2
d
0
;1 .�'C�1.O.� �lVil /p'1��� �I
I74 6 ■11i;l■11l1■■■11■■■11■D11■iI
immktliamistremme ,r-----
I110K4MMI INVII! 11 ■il ■ ■■ ■■YY■■ , ■II
\EEMBIs solig■1131D■■■■D■■■■■Ii
o NNE PAIRMa'sii ■1111■■■ ■11/11 ■III
;1EL\ ■■■■■■ ■D■Il
!It1Pc rl'>fi,k1M it•iai ■ ■ ■•111t:1 ■ ■ ■II!
rr>►�ai.t ig !ME M: �J■■■ G�,D ■ ■lij
2i1 Il a S 11E■■ ■ ■■►■■II'
I■EMES MillI RMN ■D i ■ ■■■III
- - . MESS M ■►NIIii16 ■i Mall '11■ ■ ■ ■11lil
M_IPEEN ENTIF,r1DE VENN 11111•1112111111
1111•D ■■III
1■■11G!■ 3■ ■ ■ ■11■ IMII• ■TIP
■■■D■■■G■D■n,= -=-..�.
2`" ■ ■ ■■ ■■■ ■1111.11■E117
>_ ERE Mil ■ ■■■ ■■■ 1 i
■■■■■■■g.a■■■ ■1111■■■
�■■ d1D ■■■ ■olimm ■■ m■■■I
1 I'JGiie ■ ■ ■11D ■■ ■_i ■�7M ■I I,!
I■/t ■■IW■ ■1111■/21.11■INra■■I
i■■■ ■■ %■11■ ■ ■■■■ ■■\u■■ ■■I
i■D■■■■■IE21 ■r _ - - --1
.- 111111
m■ ■11■ ■11211111
11
FINISH LEGEND
p2 MFR: ICI
COLOR: 946
FINISH: EGGSHELL
CEILING PLAN
Scale:
PAINT
MFR: BENJAMIN MOOD
COLOR: 1534
FINISH: EGGSHELL
PLASTIC LAMINATE
MFG: NEVAMAR
COLOR: S -6 -17 BLACK
FINISH: TEXTURED
LOCATION: WALL & BASE CABINETS
EXISTING FINISH TO REMAIN
FINISH KEY NOTES
0 SEE 15/IA -9.1 FOR FLOOR PATTERN.
O CONTRACTOR TO CLEAN &SEAL CONCRETE
FLOOR BEFORE INSTAWNG NEW VINYL FLOOR.
FINISH GENERAL NOTES
1. ALL INTERFACE CARPETS TO BE INSTALLED BY CERTIFIED INTERFACE
CARPET INSTALLERS.
CF SALES - 206 - 447 -9732
RESOURCE WASHINGTON - 206- 622 -5163
FLOORING IS TO BE Cl THROUGHOUT, U.N.O.
WALLS ARE TO BE PAINTED P1, U.N.O.
WALL BASE IS RBI, U.N.O. PROVIDE IN COIL LENGTH TO MINIMIZE
SEAMS.
5_ PREP & FLOAT THE EXISTING SUBFLOOR AS REQUIRED THROUGHOUT.
LABOR IS TO BE ACCOMPLISHED AS PER FLOORING MFG.
RECOMMENDATION TO ENSURE MFG. WARRANTY OF FLOORING MATERIAL
PRIOR OR INSTALLATION.
6. NO PAINTING OR INFERIOR FINISHING IS TO BE DONE UNDER CONDITIONS
WHICH WILL JEOPARDIZE THE QUALITY OF APPEARANCE OF SUCH WORK.
Z. PRIOR TO PAINTING, DRYWALL MUST BE CLEAN & DRY. NAIL HEADS
MUST BE SET & SPACKLED. JOINTS MUST BE TAPED & COVERED WITH
JOINT COMPOUND. SPACKLED NAIL HEADS & TAPE JOINTS MUST BE
SANDED SMOOTH & DUST REMOVED.
8. CRACKS, HOLES, IMPERFECTIONS IN EXISTING WALLS, PARBRONS OR
GYPSUM BOARD ARE TO BE FILLED WITH PATCHING PLASTER &
SMOOTHED OFF TO MATCH ADJOINING SURFACES.
9. PROVIDE TENANT WITH BRUSH -OUTS OF EACH PAINT COLOR & FINISH
FOR APPROVAL AT LEAST TWO WEEKS PRIOR TO S. APPLICATION.
ON -SITE APPLICATION IS REQUIRED ONE WEEK PRIOR TO FINAL
APPROVAL
10. EXISTING POWER /DATA SWITCH /OUTLET COVERS & ALL SURFACE
HARDWARE TO BE REMOVED & STORED FOR REUSE PRIOR TO PAINTING,
& REINSTALLED AFTER PAINTING.
11. NEW ELECTRICAL SWITCH & OUTLET COVER PLATES, SURFACE HARDWARE,
ETC. ARE TO BE INSTALLED AFTER PAINTING & ARE TO MATCH EXISTING.
12 CONTRACTOR IS RESPONSIBLE FOR ALLOWING FOR DELIVERY & LEAD
TIMES FOR ALL FINISHED WITHIN THE CONSTRUCTION SCHEDULE
DELIVERY TIMES MUST BE CONFIRMED. EXCESSIVE LEAD TIMES MUST BE
BROUGHT TO THE ARCHITECTS AITENT1ON IMMEDIATELY.
13. SEE FINISH PAM, ELEVATIONS & DETAILS FOR CLARIFICATION OF EXTENT
OF FINISH MATERIALS.
14. INTERSECTIONS OF FLOOR FINISH MATERIALS ARE TO BE LOCATED
DIRECTLY UNDER CENTER OF DOOR, WHERE OCCURS, U.N.O.
75. FOLLOW MANUFACTURER. PROVIDED DETAILED INSTALLATION GUIDELINES &
USE MANUFACTURER RECOMMENDED ADHESIVE PRODUCT & TOOLS AS
REQUIRED. PROVIDE TENANT WITH MANUFACTURER RECOMMENDED CARE
& MAINTENANCE INSTRUCTIONS.
16. EXISTING WALLS TO BE RE- PAINTED ARE TO RECEIVE (2) COATS OF
PRIMER PRIOR TO PAINTING.
DEMO GENERAL NOTES
WHERE EXISTING POWER / DATA/TELECOM OUTLETS ARE
INDICATED FOR REMOVAL, ALL ASSOCIATED WIRE,
CONDUIT, JUNCTION BOXES, & ACCESORIES SHALL
ALSO BE REMOVED TO THEIR POINT OF CONNECTION
AT NEAREST BREAKER PANEL NOTE VOICE & DATA
WIRING WILL BE REMOVED BY TENANT CONTRACTOR.
2.
WHERE NEW POWER /DATA/TELECOM OUTLETS ARE
INDICATED ADJACENT TO THOSE IDENTIFIED FOR
REMOVAL, CONTRACTOR SHALL REUSE EXISTING
CONDUIT & JUNCTION BOXES WHERE POSSIBLE &
CONSISTENT WITH APPLICABLE CODES.
DEMO KEY NOTES
O WALL TO BE REMOVED.
O DOOR, FRAME, & HARDWARE TO BE RELOCATED.
FLOOR GENERAL NOTES
2.
13
14
15
16
17
18
79
20
27
23
24
25
1. CONTRACTOR SHALL MAINTAIN A CLEAR & UNOBSTRUCTED
PATH TO EXITS AT ALL TIMES.
PROVIDE FIRE TREATED WOOD BLOCKING OR EQUIVALENT
SHEET METAL AT ALL WALL MOUNTED MILLWORK & HARDWARE.
3. ALL NEW WALL CONSTRUCTION TO BE BUILDING STANDARD
U.N.O. WALL CONSTRUCTION TO BOTTOM OF ACT GRID 11.5.0.
ALL INSULATION MATERIALS; INCLUDING FACINGS. SUCH AS
VAPOR BARRIERS OR BREATHE PAPERS INSTALLED WITHIN
FLOOR- CEILING ASSEMBLIES, WALLS CRAWL SPACES. OR
ATTICS, SHALL HAVE A FLAME - SPREAD RATING NOT TO
EXCEED 25 & A SMOKE DENSITY NOT TO EXCEED 450 WHEN
TESTED IN ACCORDANCE WITH U.B.C. STANDARD 8.1.
4.
5.
DOORS ARE EXISTING U.N.O.
FLOOR KEY NOTES
O EXIG PAINTED Taco 80ARD 4k8k3 /4 FIRE TREATED
PLYW TOUCH UP TO MATCH NEW ROOM PAINT.
O PROVIDE 24/7 COOLING IN NOTED AREA
O PROVIDE WIRE MESH ABOVE EXISTING WALL.
O EXISTING FIRE HOSE (36" MIN. CLEARANCE)
O S EXISTING FIRE PIPING.
O NEW COPIER 81' TENANT (USING 11X1.50 POWER).
O NEW PROXIMITY CARD READER.
LA Co PROVIDED & INSTALL MICROWAVE.
PROVIDE & INSTALL REFRIGERATOR.
DUSTING WALL TO BE EXTENDED FULL HEIGHT PER DETAIL
11 9/IA -9.1.
O PROVIDE. & INSTALL DISPOSAL & INSTA -HOT TO EXISTING SINK.
12,
PULL EXISTING WIRE AND PROVIDE BLANK COVER PLATE.
NEW CABINETS TO MATCH EXISTING. SEE 19/IA -9.1 FOR
ELEVATION.
RELOCATED FIRE EXTINGUISHER CABINET ® 54" AF.F. PROVIDE
IDENTIFICATION SIGNAGE AT EACH EXTINGUISHER LOCATION AS
REQUIRED.
REMOVE EXISTING WIRE AND PULL NEW PER COMPAQ STANDARDS.
SERVER/TELCO CABINET BY TENANT.
208V - 30 AMP DEDICATED OUTLET.
NEMA DEDICATED NEUTRAL FOR MISC. SYSTEMS.
NEMA ULIGAI u NEJTRA1 FOR PBX & VOICE MAIL U.P.S.
POWER FOR SECURITY SYSTEM TRANSFORMER (ABOVE CEILNG).
PULL WIRE, PATCH AND PAINT OPENING.
TENANT PROVIDED P.D.U.
CONVERT POWER TO FOURPLEX.
TENANT PROVIDED WALL MOUNTED MAIL BOX UNIT. CONTRACTOR
TO INSTALL & PAINT DARK GRAY (TENANT TO PROVIDE SAMPLE TO
MATCH) VERIFY FINAL LOCATION W/TENANT.
FURR -0UT & INSULATE EXTERIOR WAREHOUSE WALLS PER
MECHANICAL CONTRACTOR.
CEILING GENERAL NOTES
1. CONTRACTOR TO MODIFY EXISTING FIRE SPRINKLER SYSTEM
AS NECESSARY TO ACCOMMODATE REVISED FLOOR PLAN.
2. FIRE SPRINKLER DRAWINGS TO BE SUBMITTED TO TENANT
FOR REVIEW & APPROVAL PRIOR TO START OF WORK.
3. SUPPLEMENTAL SUPPORT WIRES FOR ELECTRICAL CONDUIT
SHALL BE ATTACHED ONLY TO MAIN RUNNERS & LOCATED
AT INTERSECTIONS WITH CROSSING GRID.
4. ALL ABOVE - CEILING CONDUIT SHALL BE INSTALLED DIRECTLY
ABOVE & PARALLEL TO CEILING GRID MEMBERS UNLESS
OTHERWISE NECESSARY FOR SAFETY OR CODE COMPLIANCE
5. INSTALL SEISMIC BRACING PER DETAIL 14/IA -9.1
ACOUSTICAL CEILING GRID SYSTEM, TYP.
CEILING KEY NOTES
O PATCH /REPLACE DAMAGED CEILING TILES TO MATCH EXISTING.
O 2 PROVI DE ° BLOW -IN ACOUSTICAL INSULATION ® WALLS IF NOT
EXISTING & A 2' -0" PERIMETER AT DOLING.
0 BUILDING STANDARD 2X4 FLUORESCENT LIGHTING. VERIFY EACH
SPECIFIC FIXTURE FOR SPECIAL REQUIREMENT DESIGNATION. D
= DEMOLISH (SALVAGE); E = EXISTING (TO REMAIN); R
RELOCATED; N = NEW (MATCH EXISTING STANDARD). REFER TO
DESIGN -BUILD DOCUMENTS FOR ADDITIONAL INFORMATION.
O HATCHED AREA INDICATES EXTENTS OF NEW 2x4 CEILNG GRID
TO MATCH. EXISTING.
O WALL OR CEILING MOUNTED ILLUMINATED EXIT LIGHT. REFER TO
DESIGN -8U. DOCUMENTS FOR ADDITIONAL INFORMATION.
O SUSPEND NEW. ACT ® 8 -6" ABOVE OFFICE SPACE TO MATCH
EXISTING CONDITION.
4 RELOCATE EXISTING FLUORESCENT FIXTURE.
JPC `ARCHITECTS
13201 Bei -Red RdB�ewo4 WA 98005
tel a25- bat -02nq fmc�a25- 631EZ0a
COMPAa
CUSTOMER
SERVICES
OFFICE
Design Team
Pram
o.aaa
TUKWILA, WASHINGTON
JPC
M.R., LG.
C.P.
Datr 11/13/01
"'" -100 -0454
oTtoov6
MAR + g 1.991
��70X
iS1
Na mtr 0.aabum
11/20/01 SPACE PLAN
12/21/01 755 PROGRESS SET
01/04/02 957 PROGRESS SU
01/15/02 1007 CONST. ISSUE
01/27/02 CLIENT REVISIONS
Q 02/01/02 CLIENT REVISIONS
CITY OF ?U
MAR - 5 2002
PERMITCEP5R
MO2 -044
2724141
FINISH,
FURNITURE &
CEILING PLAN
VV CC4VA N 1 C./►L.,
immessmo
IA-3.1
2001, x AidiGCb, uc