HomeMy WebLinkAboutPermit M02-049 - HALLWOOD REAL ESTATEHALEWOOD REAL ESTATE 340 ANDOVER PK E M02 -049 t LUm 000 N Nu. W g LL Q: co • d O LLI U0 0- 0 I- ll! UJ. LL O WZ UN OF Parcel No.: 0223200032 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: FIVE STAR MECHANICAL Address: 3902 W VALLEY HY STE 200, AUBURN WA Contractor License No: FIVESM *010JT DESCRIPTION OF WORK: REPLACE 2 ROOF TOP PACKAGE HEAT PUMPS WITH 2 GAS ELECTRIC UNITS. Value of Construction: Type of Fire Protection: Permit Center Authorized Signature: KccL I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied- ' ith, whether specified herein or not. The granting of regulating co Signature: doc: Mech City of 'Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 HALLWOOD REAL ESTATE 340 ANDOVER PK E, TUKWILA, WA ROSELLINI ALBERT D PREMIUM DISTRIBUTORS INC, 5930 6TH AVE S RICHARD GARCIA 3902 WEST VALLEY HY, #200, AUBURN WA $4,000.00 MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: Fees Collected: Uniform Mechnical Code Edition: Date: Print Name: • �� 11� Phone: Phone: 206 - 786 -8894 Phone: 253 - 833 -8284 Expiration Date: 04/30/2002 MO2 -049 04/01/2002 09/28/2002 $90.25 1997 presume to give authority to violate or cancel the provisions of any other state or local laws of work. I am authorized to sign and obtain this mechanical permit. ti This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -049 Date: 4/ t Printed: 04 -01 -2002 Parcel No.: 0223200032 Address: Suite No: Tenant: HALLWOOD REAL ESTATE doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Permit Number: MO2 -049 Status: ISSUED Applied Date: 03/13/2002 Issue Date: 04/01/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 7: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 8: Manufacturers installation instructions required on site for the building inspectors review. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto- shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 13: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 14: Duct detectors shall send a supervisory signal only upon activation. 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 17: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 18: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Chief 53. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. MO2 -049 Printed: 04 -01 -2002 City of 'Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and governing this work will be complied with, whether The granting of this permit does not presume o give regulating cons tion • the •e• • rmance f ork. Signature. I, 1.....4 _...._ _. Print Name:2IG- t--•-■2._c doc: Conditions will comply with them as outlined. All provisions of law and ordinances specified herein or not. authority to violate or cancel the provision of any other work or local laws Date: 4 1 MO2 -049 Printed: 04 -01 -2002 Project Name/Tenant: Signatu : 1 4A Date: Va Mechanical Equipment: Print name:P LM 12-C,t fr. . Site Address : '34o A .CIF 32-- s'I.t2l -- Fes` —• s'U le-- City State/Zip: • ` 1 be Tax Parcel Number: 112 • 00=32 Property Owner: •Nbt.LrW t} 7 60 12 1- - t cs� Phone: (Z) 5 , �� Street Address: 01 1AD t)s- n2 `-( 0Yz-IVG. - 1-01c --t City State/Zip: c1£S I FDA Fax #: ( ) Contractor: v1v a_-), - Mt C Hl,0L(.._ .t_ Phone: (� E9S3 • fE-s2 r Street Address: '3'1%7- VI • VANI .l.. -v y `1 •_\ • 4 200 1V(i3, City State/Zip: `6' O \ Fax #: (2.ks3) 633 • L' Contact Person: Phone: Street Address: A- City State/Zip: Fax #: �#�•• - WNW • e ' ,(.. DAGEN . .s . sr..i l;: , i iri... 1 . 1 , . Signatu : 1 4A Date: Print name:P LM 12-C,t fr. . Phone: (..zak, ) _ TEG s3.ari4 Fax #: ( ) Address: 31. \,J , VN.LLIF-( W`f FA IF City / State/Zip: .k..0‘2; 9800 1 4111 Q:1 is « "unY /!/2/99 meth pamin.doc CITY OF TWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 'Project Numb Permit Number: Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. i� I �. .V :I �YI'. nr«c i.:.:J M••,P• i ;, :: i, Mr• v:1: ••..4:•� "I �. ••. P': un: '4Y'j Y' IG•'Alq.b h ': �� .: � �.„ , «•,, �,.�.';:w �:�,�,,._.Ln.•.,c, �.,: �.. �,�, );'�t11?I� agiCiAli 'R' ,r' ` tifOIEVy`A ND APi!ROVAL?R QUESTED. "(T�?gE;1�/LLED OUT BY'APPLIGIN Description of work to be done (please be specific): tZ t L_A c 2 C� "a Zr -rv'? 'Pa c -te-4% G P U P •v.) / y. Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the ` State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OFPERJURY,iY THE LAWS OF T ESTATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of. Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: 9 -•• Application ken lam: (initials) #3Z ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -15 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal • 9/21/99 miscpml.doc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requirements New Single Family Residence Heat loss calculations with specifications or Form H - 6. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. " 1 ■ Parcel No.: 0223200032 Permit Number: MO2 -049 Address: Status: APPROVED Suite No: Applied Date: 03/13/2002 Applicant: HALLWOOD REAL ESTATE Issue Date: Receipt No.: R020000425 Payment Amount: 90.25 Initials: KAS Payment Date: 04/01/2002 01:39 PM User ID: 1684 Balance: $0.00 Payee: FIVE STAR MECHANICAL TRANSACTION LIST: Amount City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Type Payment Check 11534 ACCOUNT ITEM LIST: Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Method Description 90.25 Description Account Code 000/322.100 72.20 000/345.830 18.05 Total: 90.25 -;;.`., 04/02 710 TOTAL AL 90. 25 Printed: 04 -01 -2002 r t Inspector: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 r r`C Address: . 3 Afr, we - IL Special instructions: Type of Inspection: r --, Date called: - 7 — 17 Date wanted: a.m. _ 1 -iS---U) Requester: Phone: Approved per applicable codes. Corrections required prior to approval. COMMENTS: -- A ) pirwki Covv)01-f 0V_ El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Date: PERMIT NO. (206)431 -3670 re W 0 cu 0 N 9 WO u_ ? . co d ju D O 0 W W O . U =. O~ Z Proj t ` a 't"ttlr VCe iiii a(2 Type of Inspe tion: Shirts -� Svv t P Shirt ..\YJ'�/ti Address: A i Date called: Special instructions: Date wanted: "7 — I0 - 0- a.m. .m Requester: Phone: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Pakt- - V.0 ` tr �\ ' \1t I'! Cw 4 (' f t he C Ov 14.` 1 Inspector. Q $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: tiSieif r $ kraratah �x :i w PERMIT NO. (206)431 -3670 Date: Project: N Type of Inspection: ZO0 till/ e . Address: 2 (3 90 APE) Date called: -_ a ^ 0- Special instructions: Date wanted: �- 3 a.m Requester;, thew ^e t Phone: iv, -gg9'1 INSPECTION NO. pr'oved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 ❑ Corrections required prior to approval. COMMENTS; 0 $47. 0 E REQUIR D. Prior to inspection, fee must be paid at 6300 Southcenter BIv.., Suite 100. Call to schedule reinspection. Receipt No: Date: �s: •`2 •�..): J�� f � ' �47t.1 , }.%4 Project Name / / /u..u,,J D r ( Address c/ o 0. ti o 1 _, d J - .) FINALAPP.FRM . yf .;;y';: .✓y'. '"C�'." i•ES �r Kblypa..�. s wx: a �.7d t. : City of Tukwila Fire Department TURWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature [ P o - tJ / John W. Rants, Mayor Thomas P. Keefe, Fire Chief MO.1 - o<<�✓ Permit No. .0 0 . 1 '03,) Date T.F.D. Form F.P. 85 Suite # /t, -u :2, Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 57$4439 FILE. Fy SEPARATE PERMIT REQUIRED ❑ ELECTRICAL 0 PLUMBING GAS PIPING CITY OFTUKWILA BUILIN � Sl' �� l REVISIONS ,,���.- TO NO CHANGES SHALL I THr: SCOPE OF WORK � ITHO ` 1T ?RIC 7, i QVAL OF Tub NEW r - +_�:; .. TE: FEVI:;iONS WILL REQUIFr. SAN �! f: '1 October 2001 2nd Reprint February 2002 Precedentrm 3- 10Tons -60 Hz Packaged Gas/Electric Rooftop units CITY Of TUKWU.A APPROVED MAR 2 9 2002 o AS KO la) RECEIVED CFTV OF TUKWILA MAR 1 5 200? PERMIT CENTER RT- PRCOO6 -EN 1v;wz-o 4q z re 6 00 co J N WD gQ CO = I--w zj_ I-0 W ~ w U� o � w II o Z U= 0' z Table GO-z- General Data ftT- PRCOS6 -EN YS 1 MINE" _ (5 - 6 Tons) General Data Standard Efficiency 5-Ton Convertible 6 -Ton Convertible YSC060A3, A4, AW YSC072A3, A4, AW Cooling Prrflonoono*' Gross Cooling Capacity 63,100 63,100 72,000 SEER/EER 9.90 10.201- - 110.2 Nominal CFM /ARI Rated CFM 2,000/2,000 2,000/2,000 2,400/2,100 ARI Net Cooling Capacity 60 ,000 60,000 69,000 Integrated Part Load Values - - - System Power (KW) 6.86 6.78 6.77 Heating Performance Heating Models Low Medium High Low Medium High Low Medium High Heating Input (Btu) 60,000 80,000 130,000 60,000 80,000 130,000 80,000 120,000 150,000 Heating Output (Btu) 47,000 63,000 103,000 48,000 64,000 104,000 64,800 97,200 121,500 AFUE % 81 81 80 81 81 80 81 81 81 Steady State Efficiency (96) 81 81 80 81 81 80 81 81 81 No. Burners 2 2 3 2 2 3 2 3 3 No. Stages 1 1 1 1 1 1 1 1 2 pp Gaffs Connection Pipe Sim fin.) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 NoiType 1IClimatuf Scroll 1!Climatuff Scroll 1 /Climatuff Scroll Outdoor load Rating (dB) 83 83 90 Outdoor Coil -Type Lanced Lanced Lanced Tube Sim (in.) OD 0.3125 0.3125 0,3125 Face Area (sq ft) 8.81 8.81 13.88 Rows/FPI 2/17 2/17 2/17 Indoor Co il -Type Lanced Lanced Lanced Tube Size On.) 0.3125 0.3125 0.3125 Face Area (sq ft) 5.00 5.00 9.89 Rows/FPI 3/16 3/16 2/16 Refrigerant Control Short Orifice Short Orifice Short Orifice Drain Connection No./Size (in.) 1/3/4 NPT WA NPT 113/4 NPT Outdoor Fan -Type Propeller Propeller Propeller No. UsetWiameter (in.) 1/22 1/22 1/26 DriveType/No. Spends Direct/1 Direct/1 Direct/1 CFM 3,470 3,470 No. Motors/HP 1/0.33 1/0.33 1/0.70 Motor RPM 1075 1,075 1,075 Moot Deena Indoor Fan -Type FC Centrifugal FC Centrifugal N/A No. Used/Diameter (in.) 1/11 x 11' 1/11 x 11° N/A DriveType/No. Speeds Direct/2 Direct/2 N/A No. Motors 1 1 N/A Motor HP (Standard/Oversized) 0.9011.00 0.90/1.00 N/A Motor RPM (Standard/Oversized) 985/1,080 985/1,0819 N/A Motor Frame Sim (Standard/Oversized) 48/48 48/48 N/A Dalt Drive Indoor Fan -Type - FC Centrifugal FC Centrifugal No. Used/Diameter (In.) - 1/11 x 11 1/12 x 12 DriveType/No. Speeds - BeitNariable Sheave BeltNariabie Sheave No. Motors - 1 1 Motor HP (Standard/Oversized) - 1.00/- 1.0012.00 Motor RPM (Standard/Oversized) - 1,750/- 1,750/1,750 Motor Frame Size (Standard/Oversized) - 48/- 56/56 Mars -Type Furnished n Throwaway Throwaway Throwaway (No.) Sim Recommended (2) 20 x 25 x V° (2) 20 x 25 x 1 ° (4)16 x 25 x 2 RaRigarant Margo (Lbs of R -22)' 4.9 4.9 7.1 NOTES: 1-7. Sae Notes on Pate 12. 8. VSC060A Oversized Motor Fan (Ureter Is 12 x 11. 9. Motor RPM shovrn is low speed. High speed PPM Is 1100/1135. 10. Fiber size shown is for low and medium heat models. High heat model filter size recommended Is 20 x 30 x 1. 11.Optlonal 2" pleated filters also available. 12.YSC072A when used Inc horizontal application has an EER of 10.1 and System Power (kW) o16.83. 13 Z W r J U 0 0 N 0 W = CO IL J F- W q LL W• 1-0 Z W W U 0- 1-" W LL (1l fJ O • 72 Ali dimensions are in inches. 357t — DownlowAhlbw Supply and Raton Though the Bose !!titles 34 ius — Horizontal Alford' Supply and Return 33bts lbrt Cheraw end Roof Opening Dim ensional Data (3 - 5 Tors) 74' SHAW 105 MM 3 6'16' 5014M 40' ( 17 32 3/ 11 . 4 (1016M CLEARANCE 48' (1219 MM) CLEARANCE 37' (940 MM) /\ 211? 5•7111A THROUGH THE E ELECTRICAL SUPPLY 3N -14 NPT CONDENSATE DRAIN 1 4 3/4' RETURN 71/4' 87 438/AM "' 225MM (6401.14) CLEARANCE HORIZONTAL FLOW -18' (457 MM) DOWNFLOW 38' (914 MM) TYPICAL ROOF OPENING • 337MM 44 1i CLEARANCE 38' (814 MM) 61/2' 311/16' 166114 MUM - 4 34' 1 1 MM X� 3 114' RT PRC006 -EN gtbb W1— Mathison Un tMd Comernbigillts (Lbi)Md Center OIGravity Dimensions (hJ Unit Maximum Weights (.bs)z Comex Weights (Lbs)1 Center of Gravity (In.) Tons Model No. Shipping Net A B C D Length Width 3 YSCO36A 534 480 151 124 96 109 32 19 YHCO36A 551 497 158 128 101 110 32 19 4 YSC048A 559 505 159 130 108 109 33 19 YHCO4BA 593 166 133 114 126 32 20 VSC060A 576 522 ) 169 134 105 114 32 18 YHCO6OA 628 ° 179 140 119 136 32 20 6 YSC072A 822 735 249 193 132 161 39 21 YHC072A 859 772 249 198 141 184 39 22 YSC090A 907 820 273 206 146 193 38 22 714 YSC092A 909 822 277 222 147 175 40 21 YHC092A 1010 923 306 243 165 210 39 22 Y5C102A 986 899 297 243 165 194 40 21 YHC102A 1044 957 310 252 175 220 40 22 10 YSC120A 1074 987 325 265 183 213 40 21 YHC120A 1147 1060 342 277 197 245 40 22 NOTE: 1. Comer weights are given for information only. 2. Weights are approximate. RTPRC006•EN Weights CENTER OP ORAVITY WIDTH D CENTER OF GRAVITY CENTER OF GRAVITY LENGTH NabieW2— Factory*stalIed Options AletIlikiights (Lbs) Accessory Economizer Barometric Relief Powered Exhaust • ff011111l Net Weight 3.5Tons 6.10Tons 26 36 7 10 80 Motorized Outside Air Damper 20 30 Manual Outside Air Damper 16 26 Roof Curb 70 115 Oversized Motor 5 8 Belt Drive Motor 31 — Smake Detector, Return 7 7 Smoke Detector, Supply 5 5 Coil Guards 12 20 Hinged Doors 10 12 Powered Convenience Outlet 38 38 Through the Base Electrical 8 13 Through the Base Gas 5 5 Unit Mounted Circuit Breaker 5 5 Unit Mounted Disconnect 5 5 Novar Conlrol 8 8 NOTES: 1.Weights for optbns not listed are >5 lb s. 2.Net weight should be added to unit weight when ordering factor•lnstalled accessories. 79 SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL 0 ELECTRICAL 0 PLUMBING 0 GAS PIPING CITY BUILDING TUKWILA DIV S BUILD ION Documentation of Existing HVAC Units 1! ,,: . r t 17C.r Weights and Installation 340 Andover Park East Tukwila Washington 98188 MAR 1 5 2002 CITY Of TUKWILA APPROVED MAR 2 9 2002 AS NO I ED Jain' E 1LCOOG oivraM RECEIVED CITY OF TUKWILA PERMIT CENTER .... Modd No. ■■■■■....a..............7 Evaporator Air 110F 0 Gelb asinine. Air T ratios Ente ' Condoner (F) CHAII-511-513 N 105 CHAO-851453 1Cooling CsPoeill/ Alai Certified Told capacity I Bulb) Total Air Volume mho 49.000 Comp. Mater Input Watts -............-.....4.........-____. 59.000 TOW unit watts Comp. Total Motor Cooling limpid Capacity Warn (Stub) 7407 Comp. Motor input Mans 8800 Dehumidifying capacity I 23% ___ 63 26% 9loynn wheel num. divan. x wsd. (in.) 1 5430 (21 10 x 6 .91 421 10 x 6 Blower Motor hp. 6100 38900 .97 1/2 1800 1/2 Refrigerant 1N-22/ dliaDe 5510 I 48,700 8 Ibs. 12 os. 5820 44.800 8 lbs. 11 oz. Condenser Coil Net E ace area Isis. (t.) 6560 2000 6.95 .99 8,33 1W-3 Tube diem. (WiTichlo. ol rows .94 5890 48.000 1T2-3 6320 I 41.500 Fins cits inch 6650 67 13 55.500 13 Condenser Fan [Nom fin.) & No. of &toles .76 5990 1 47,200 26-5 I e. 6420 I 42,500 26-5 Air volume (tectoly setting! Motor hp Motor watts (factory oath Net face arez hq. ft.? .85 8750 • 4100 56.600 4320 .5670 5730 I 52.300 112 6060 48,000 1/2 6480 I 43.500 670 3.75 6820 ' 670 4.58 Evaporator Coil Tube dints. l(n.I & No. of .54 Vi I 1/2-4 MEAN 112-4 Fins peg inch .57 6660 I 46.500 10 7080 10 1 I No. & site of Mhos lin.) den Consate T drain sire tAP isn.1 .55 5860 11) 161f2 x 31-112 it 1 (1) 16-ta x 27-7/8 x 1 .57 (1) 16.1)2 a 31-1/2 x 1 .- II) 16-1/2 It 27-718 ' 3/4 - 3 '11111111111 Net weight of basic units Ms) 11-P.1 7160 2000 770 .56 800 0110011111 Out finclosure (Without Power Saver) .59 6330 52.800 RT8-65 - 6830 I 48.400 lbs. Optional Duct Endosime with Power Saver & Controls Encino:II E99- Lfi4611HD 63 2000 RD8-65 - '350 lbs. Optional Roof Mountyrairrie 'Optional Minimum 6ptional Combination And Return Step 6670 55,000 .98 6850 RMF3.65 - • 100 lbs. Fresh Air Damper 7240 44,200 .96 7870 0A173-65 - '7 lbs. Ceiling Supply Down Diffuser .87 1 57.200 RTD-65 - 52 lbs. Optional Combination Ceiling Supply And Return Flush Diffusor 52.000 .94 7380 46.500 FO-65 - '26 lbs. i 2500 • "F D-66-0 - 33 lbs. Combination Supply Return Air Duet 6 uses 58.700 .92 7170 P-89592- -36 mi. 1R D F f i g l i f j 7520 I 48.800 Mar 12 02 03:29p fN.OTE-Rated In. accordepps.woh AR) SundenS.210: 460 elm artepormsestrmotomatsw. ton of.co011earcapacity, 95F autdoor.eir_toroPoratunitets1...:, .110db/67usts.entarI1lganteporatot •r. t tClustanst. polyurethane filar media, 'Net weight • •Flustsdiffusee with adludablabeff/a Maass. - • ... Pam Whitelam .1Z 71 .1;-„Lt • . . . •:, •". A 4;...17 ^ " " fit • • ft.- " • ren BUISING86761/MIMMM1950/10IMS OMSOLDPattnnetelltet~traval%st s ..,,- SPECIFICATIONS. RATINGS .kr. •411.4 25371372-4613 P • 2 ft7 Evaporator Air 110F 0 Gelb asinine. Air T ratios Ente ' Condoner (F) 05 N 105 115 Unit Model No. Erruf km Wit Bulb Degrees IF) Total Air Volume mho Comp. Mater Input Watts Total Cooling Capacity (Stub) Sensible To Total Ratio IS(T) Comp. Total Motor Cooling limpid Capacity Warn (Stub) Semible To Total Ratio MITI Comp. Motor input Mans Total Cooling Capacity (Stub) Sonsibla To Teasel Ratio (SIT) till _. EL9119 ___ 63 1600 51.200 .87 5430 46.800 .91 5690 I 43,000 .94 6100 38900 .97 6430 1800 52.700 .88 5510 I 48,700 .92 5820 44.800 .96 8230 I 40,400 .99 6560 2000 54,000 .99 5500 49,800 .94 5890 48.000 .95 6320 I 41.500 1.00 6650 67 18(10 55.500 MO .72 IggelE4111•111E1111111ErtAllIGL 51.300 .76 5990 1 47,200 .79 I e. 6420 I 42,500 .85 8750 • 2000 56.600 .76 .5670 5730 I 52.300 .79 6060 48,000 .82 6480 I 43.500 ._ .86 6820 ' 71 1. 1 . •. r. .54 Vi I 000 MEAN 6170 50 500 .57 6660 I 46.500 . • 7080 1800 58,900 .55 5860 55.100 .57 6260 51,500 1 6740 1 47,500 .61 7160 2000 59,800 .56 5910 56.400 .59 6330 52.800 .61 6830 I 48.400 .83 7240 E99- Lfi4611HD 63 2000 68.600 .85 6670 55,000 .98 6850 49.800 .92 7240 44,200 .96 7870 2250 60.300 .87 8670 57.200 .90 7080 52.000 .94 7380 46.500 -98 7530 2500 61.700 .90 6740 58.700 .92 7170 54.100 .96 7520 I 48.800 1.00 8000. - 67 2000 ' 61,800 .71 6760 59,100 .73 7190 54,200 .75 _ 7520 I 48,900 .78 2250 63,500 .72 6830 GO ■ .74 7290 56.100 .77 7660 I 51,100 .79 8170 ° 2500 64.700 .73 6900 52.200 .75 7370 57.700 .78 7750 52,800 .81 8300 .. 71 2000 84.800 .53 6900 62200 .54 1370 57,600 .56 7760 I 52.800 .57 ,_ 8300 • 2250 06,100 .56 6870 63,500 .56 7450 59,200 .57 7860 54.300 .58 8410 ' 2500 67,300 .56 7040 I 64.900 .57 7530 61,000 .513 MOO 58200 .60 8520. Mar 12 02 03:29p fN.OTE-Rated In. accordepps.woh AR) SundenS.210: 460 elm artepormsestrmotomatsw. ton of.co011earcapacity, 95F autdoor.eir_toroPoratunitets1...:, .110db/67usts.entarI1lganteporatot •r. t tClustanst. polyurethane filar media, 'Net weight • •Flustsdiffusee with adludablabeff/a Maass. - • ... Pam Whitelam .1Z 71 .1;-„Lt • . . . •:, •". A 4;...17 ^ " " fit • • ft.- " • ren BUISING86761/MIMMM1950/10IMS OMSOLDPattnnetelltet~traval%st s ..,,- SPECIFICATIONS. RATINGS .kr. •411.4 25371372-4613 P • 2 ft7 CHAR -1353 CHAR -1853 CHAR -2753 CHAS-953 196,000 12,700 26% 16 lbs. 12) - 12 x 6 2 3 10.2 318- 4 18 121 22- 5 6000 (21 1/2 1100 7.4 318 - 4 13 li2 (1120x25x1 116x2551 1425 CHAS -1353 t 130,000 17,100 28% 17 lbs. (21 -15x9 3 5 13.8 319 - 4 18 12) 22 -5 7550 (21 3/4 1640 9.4 318 -4 13 16) 16 x 20 x 1 CHAS -1853 200,000 25.000 29% 40 lbs. (2) -15x11 3 5 (2) 10.75 ea. 112 -4 13 (21 25 -112 - 6 13,500 (21 1 2820 12) 7.67 ea. 112 -4 13 14)20520x1 (4)16520x1 1.114 785 CHAR -2713 273,000 35 500 26% 48 lbs. (2) - 15 r 15 5 7.112 (2) 12.15 ea. 112 -6 13 (2125.112 -6 13,250 Outdoor Air Temperature Entering Coadenser (F) 115 Total Sensible Comp. Coding to Total Motor panty Ratio Watts tub 3000 3375 3750 3000 3375 3750 5500 4400 4950 5500 6000 6750 7500 8800 9900 85 95 105 Total Sonsible Comp. Total Sensible Comp. Total Sensitts Comp. Cooling to Total Motor Cooling to Total Motor Cooling to Total Motor Capacity Ratio Watts • icily Ratio Watts parity Ratio Watts t • . SIT In . ut Brim+ d 1 '.t ti . ,u 1 98,000 100,000 102,000 106.000 108.000 109,000 113,000 115.000 135,000 138.000 139.000 143.000 145.000 146,000 150,000 152,000 155.000 191,600 195.500 199.100 206.600 210.900 214.900 222.200 226,400 230,400 261.000 266 500 282,600 288,500 304,500 309,800 .91 .93 .97 .73 .75 76 90 .71 .73 .52 .53 .54 .89 .92 .70 .73 .54 .55 8900 9000 9100 9300 9400 9500 12,300 12,400 12.600 12,800 12,900 13.000 13.200 13,300 17.100 17.300 18.600 18.900 19.100 25,100 25.300 26.000 26.400 27.300 27.600 133.000 136.000 138,000 93,000 95,000 96, 000 100.000 102.000 104 000 107,000 111,000 129,000 131.000 140,000 143,000 148.000 148.000 181.400 185,000 195.800 199.800 203 400 210.600 214,500 218.100 248.000 252.500 268.000 273,000 288.000 292.600 .94 98 t.00 .74 76 .77 .93 .72 75 .77 .59 .61 .63 .53 .54 .55 .92 .95 .72 .75 .55 .56 9500 9600 9700 9900 10.000 10100 10.300 13.200 13.400 13. 13,600 13,800 14.000 14 200 18,400 19,500 19.700 20.200 20.400 20.600 26. 26.800 27,700 28,000 29.000 29 300 88,000 89.000 91.000 95.000 96,000 98,000 .96 1.00 1.00 .77 .78 .80 102.000 123.000_ .89 125.000 .92 133.000 .BD 136.000 .61 138.000 .63 141 000 .64 170.8170 174.000 104.600 .71 188.200 .73 191 300 198.300 .54 201.800 .55 205.000 , .56 235.000 .94 239.200 .97 254,000 .74 258,000 .76 272.000 .56 276 000 .58 10.200 10,300 10,400 10,700 10,800 10.900 11,200 11,300 14,000 14.200 14.300 14.400 14,600 14.700 14.800 20,800 21.200 29.400 29.70 30,800 31.200 21.600 22.000 22,000 28,100 28.400 83.000 84,000 86.000 89.000 91.000 92.000 115,000 117.000 118,000 121,000 123.000 125,000 127.000 129.000 131.000 160,100 162.900 165,700 173.100 176,300 179 200 186,100 189,100 192,000 222.000 226.500 239.400 242.700 255.800 259.500 (2) 1 2500 (2) 9.75 ea. 18) 20520x 1.00 1.00 1.00 .78 .80 83 1.00 .77 .80 .82 63 .65 .67 .55 .56 56 .98 1.00 .76 .78 .58 .59 11,200 11.300 11,400 11.600 11,800 11.900 12,100 12,200 12.300 15,100 .15.300 15,400 15,500 15.700 15.800 15.900 22,200 22.400 23,000 23,200 23,500 30.000 30 300 31.500 31,800 32,900 33 200 Condenser Coil Condenser Fan Evaporator Coil No. & size of filters (in.) Net taco area (sq h.) Tube diam. (in.) a No. of rows Fins per inch Diem. (in.) & No. of blades Air volume (cfml Motor hp Net face area Tube diam. (in.) 8. No. of rows Fins per inch Condensate drain site MPT (in.) Net wei • ht of basic unit lbs ,y • . . • - �� r i,' ''� om : tt ••k Mar 12 02 03:29p Blower Motor Hp See Drive Selection Table Minimum Maximum .wi Modal Mo. 'Cooling Capacity[Total capacity IBtuh) (SARI Standard Total unit watts Conditions Oshumidi yinq capacity Refrigerant charge 18-22) Blower wheel nom. diem. x arid. (in.) Pam Wh i teel am �&J 253 -872 -4613 P.3 • 7' M ti T�tirP�r ' . Ear 1 Z W 6 U 0 Ill = H Ili 0 g = • d 1- W Z = I- 0 ZI- W uJ U � O - 0H W I- -- - I L 0 W Z P- P /' Z •;,• ja ix,?;k' 47 ;µ,; t'�: :;�'! `,Cf yu�..�,.r „ � ..� , p [his is a typical picture ol'the 5 -ton units. 1' I hik is a picture o[tihc 7 -ton unit pan lain hcains Weight Comparison Existing Lennox 7 1 /2 ton unit weight = New Trane 7 1 /2 ton unit weight = Existing Lennox 5 ton unit weight = New Trane 5 ton unit weight = 820 lbs. 522 lbs. 1425 lbs. 800 lbs. ACTIVITY NUMBER: MO2 -049 DATE: 3 -15 -02 PROJECT NAME: HALLWOOD- VACANT SITE ADDRESS: 340 ANDOVER PARK EAST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building 'vision II fi '3 'Ig -�i Public 'Works REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.28 -02 �.:RMIT COORD COPY PLAN REVIEW /ROUTING SLIP PMT Fire Prevention in Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete d Comments: Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Approved with Conditions TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ DUE DATE: 3 -19-02 DATE: Planning Division Permit Coordinator Not Applicable ❑ DUE DATE: 4-16 -02 ❑ Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY DATE: , • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -049 PROJECT NAME: HALLWOOD- VACANT SITE ADDRESS: ° 34U ANDOVELPARKIAST Response to Correction Letter # DATE: 3 -15 -02 I natccriN Dr. X Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works vIt DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [je Comments: Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review equired ❑ No further Review Required M. ------ REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator ❑ DUE DATE: 3-19-02 Not Applicable ❑ DATE: — iC( —ZOO'S DUE DATE: 4 -16-02 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT NO.: /4D Z'd' MECHANICAL PERMIT APPLICATIONS INSPECTIONS O 2 ❑ 50 ❑ 60 ❑ 610 ❑ 700 o 1080 (E 1090 1100 ❑ 1101 ❑ 1102 ❑ 1105 ❑ 1115 ❑ 1400 1800 ❑ 4015 Pre - construction WSEC Residential WA Ventilation/Indoor AQC Chimney Installation/All Types Framing Woodstove Smoke Detector Shut Off Rough -in Mechanical Mechanical Equipment/Controls Mechanical Pip/Duct Insul Underground Mech Rough -in Motor Inspection Fire - Final Mechanical - Final Special -Smoke Control System CONDITIONS re 10001 No changes to plans unless approved by Bldg Div Er' 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I [E 10005 All permits, insp records & approved plans available ❑ 10014 Readily accessible access to roof mounted equipment 10016 Exposed insulation backing material Igir 10019 All construction to be done in conformance w /approved plans (::: 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: / ! -- '�Oo p j/,�CgvT FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) ✓ Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) 2.. Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP/1,750,000 BTU (qty) over 50 HP/1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) 2 over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $5) Add'! Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Permit Tech: Date: S-19. Date: 3 lq-z22-- ACTIVITY NUMBER: MO2 -049 DATE: 3 -15 -02 PROJECT NAME: HALLWOOD- VACANT SITE ADDRESS: 40D :Tv% cl )6 ti- X Original Plan Submittal Response to Incomplete Letter # DEPARTMENTS: Building Division Public Works DETERMINATION OF G Complete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAI :_ __..NESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route p Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.28 -02 PLAN REVIEW /ROUTING SLIP Response to Correction Letter # ❑ Approved with Conditiorps_ 5 5 \V\ r Planning Division 1 Z (\ Permit Coordinator Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision # After Permit Is Issued DUE DATE: 3-19-02 DATE: DUE DATE: 4 -16-02 Not Applicable ❑ Not Approved (attach comments) ❑ DATE: '•FVi!HM6.aY^ ,Q ownipmor1M Ill :EtrttmtA1: Aler.I' . t 1 PRW:¢1:.V41.1.n Complete ❑ Comments: DEPARTMENTS: Building Division ❑ Fire Prevention Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions. —� Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.2&02 DATE: DATE: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -049 DATE: 3 -15 -02 PROJECT NAME: HALLWOOD- VACANT SITE ADDRESS: 4 ocs. X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Planning Division Permit Coordinator DUE DATE: 3-19 -02 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ DUE DATE: 4 -16-02 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: L VOL- -rac,G 1 625.052.000 00971 F625- 052.000 (8/97) I : 625.052 -0N1 (i/97) DEPARTMENT OF LABOR AND INL' JSTR!ES r LICENSED AS PROVIDED BY LAW AS ELEC CONTR HVAC /RFRG LICENSE # EXP. DATE EC6A FIVESM* 006C3 ' 03 3/y EFFECTIVE DATE 02/21/2000 FIVE.STAR MECHANICAL 3902 W VALLEY HWY N AUBURN WA 98001 DEPARTMENT OF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR GENERAL ri t,ir': LICENSE t EXP. DATE EC01 'tFIVESM *0.09MA] .t f EFFECTIVE ,DATE'07 /01 2000 FIVE STAR MECHANICAL 3902 WEST VALLEY HWY N 200 AUBURN WA 98001 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ' EXP. DATE CCO1 ' FIVESM* 010JT _ ' a te' /� �QQ2 EFFECTIVE DATE ' . - 04/3071999 FIVE 'STAR MECHANICAL 3902 W VALLEY HWY N STE 200 AUBURN WA 98001 Mark GP-4,5 Make Model Tram YSC060ATRLA005.1 CFM Q S.P. 1900 (j .08 Fan Speed 1080 Heating Input 60K Heating Output AFUE 48K 81% Cooling Capacity 63K SEER ID Electrical Unit Require- MCA/ meats MAX 2 ^8- 30/3/60 313/30 Factory Curb NO Outside air Ecouo -miner Damper YES NO Total Neigbt 522# CONSTRUCTION NOTES AND SCOPE OF WORK I. Removal and disposal of two (2) Lennox rooftop units. II. Furnish and install two (2) Trane 5 -ton gas pack units with economizers and duct mounted smoke detectors. (208/230-three phase). III. Gas piping for above units. IV. Line and low voltage wiring connections to rooftop unit. V. Hoisting. VI. Permits. VII. Start and test of new equipment supplied by Five Star Mechanical. VIII. One-year parts and labor warranty on equipment and material furnished by Five Star Mechanical. Gas Pack Schedule Haliwood Gas Package unit — 1 Gas Package unit - 9 Gas Package unit — 2 Gas Package unit — 8 Gas Package unit — 3 Gas Package unit — 7 HVAC ROOF PLAN 1/8" 1'0" Gas Package unit - 4 (WORK IN THIS AREA ONLY Gas Package unit — 5 Gas Package unit — 6 6 u Mil -Dy9 * 0 CO z 0 In OMTE 3 t - o-z DRAWN CHECKED PROJECT NO. COMPACT DRWG. REF ORMWING N0. M -1