HomeMy WebLinkAboutPermit M02-050 - HALLWOOD REAL ESTATEM02 -050 Hallwood Boeing 340 Andover Pk East Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: 3902 WEST VALLEY HY, #200, AUBURN WA Contractor: Name: FIVE STAR MECHANICAL Address: 3902 W VALLEY HY STE 200, AUBURN WA Contractor License No: FIVESM *010JT DESCRIPTION OF WORK: REPLACE 7 ROOF TOP PACKAGE HEAT PUMP UNITS WITH 7 GAS ELECTRIC UNITS. Value of Construction: Type of Fire Protection: City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0223200032 340 ANDOVER PK E TUKW RICHARD GARCIA Permit Center Authorized Signature: The granting regulating c doc: Mech HALLWOOD REAL ESTATE 340 ANDOVER PK E, TUKWILA, WA MECHANICAL PERMIT ROSELLINI ALBERT D PREMIUM DISTRIBUTORS INC, 5930 6TH AVE S Print Namer 6 AU-C ti ti Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 - 786 -8894 Phone: 253 - 833 -8284 Expiration Date: 04/30/2002 $20,000.00 Fees Collected: Uniform Mechnical Code Edition: Nz±I1A,1icJ(i m7 J2fl MO2 -050 04/01/2002 09/28/2002 Date: 91 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. tliis permit do not presum to give authority to violate or cancel the provisions of any other state or local laws ct(n o��thperformance f work. I am authorized to sign and obtain this mechanical permit. Signature! `'F --- `"' 2 �' Date: A $242.44 1997 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -050 Printed: 04 -01 -2002 DEPARTMENTS: Bui diri� Division �' ❑ Public Works PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -050 PROJECT NAME: HALLWOOD- BOEING SITE ADDRESS: 340 ANDOVER PARK EAST X Original Plan Submittal Response to Correction Letter # DATE: 3 -15 -02 Response to Incomplete Letter # Revision # After Permit Is Issued DETERMINATION OF COMPLETENESS: Complete rd Comments: Fire Prevention ,Q Structural (Tues., Thurs.) Incomplete Planning Division Permit Coordinator DUE DATE: 3-19 -02 ‘ Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments detennined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 1E Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.29.02 DUE DATE: 4 -16-02 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: L.RMIT COORD COPY ti 1 ACTIVITY NUMBER: MO2 -050 Response to Correction Letter # DATE: 3 -15 -02 PROJECT NAME: HALLWOOD- BOEING SITE ADDRESS: 340 ANDOVER PARK EAST X Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Is Comments: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.2802 PLAN REVIEW /ROUTING SLIP Fire Prevention p Planning Division ❑ Structural ❑ Permit Coordinator ❑ Incomplete Et' DUE DATE: 3 -19-02 TUESITHURS ROUTING: Please Route ❑ Structural Review IMuir d ❑ No further Review Required REVIEWER'S INITIALS: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: -3 " I9_ 2402. DUE DATE: 4 -16-02 Not Approved (attach comments) ❑ DATE: 3' ICI-2.002_ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: U N� w LL WO LL Q co 3 W . W U (1-1 O I— WW U. O W Z O Z PERMIT NO.: t U)Z- (5O MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 2 ❑ 50 ❑ 60 ❑ 610 ❑ 700 ❑ 1080 53 1090 1100 ❑ 1101 ❑ 1102 ❑ 1105 ❑ 1115 • 1400 E 1800 ❑ 4015 Pre - construction WSEC Residential WA Ventilation /Indoor AQC Chimney Installation /All Types Framing Woodstove Smoke Detector Shut Off Rough -in Mechanical Mechanical Equipment/Controls Mechanical Pip/Duct Insul Underground Mech Rough -in Motor Inspection Fire - Final Mechanical - Final Special -Smoke Control System CONDITIONS ( 10001 No changes to plans unless approved by Bldg �/ Div l� 10002 Plumbing permits shall be obtained through King �/ Co u 10003 Electrical permits obtained through L & I 1 10005 All permits, insp records & approved plans available ( 10014 Readily accessible access to roof mounted equipment �, / 10016 Exposed insulation backing material sr 10019 All construction to be done in conformance w /approved plans ( 10027 Validity of Permit 10036 Manufacturers installation instructions required on site 10041 Ventilation is required for all new rooms & spaces • 10042 Fuel limning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: /44 t ��,v4 FEES Basic Fee (Y/N) tr Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) t✓ Add'I Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Permit Tech: Date: 3 • t - 2002 Date: q -d7 ACTIVITY NUMBER: MO2 -050 DATE: 3 -15 -02 PROJECT NAME: HALLWOOD- BOEING SITE ADDRESS: • 340 ANDOVER PARK EAST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division ❑ Fire Prevention Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: Incomplete APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.28-02 PLAN REVIEW /ROUTING SLIP 0 TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator DUE DATE: 3-19 -02 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 0 DUE DATE: 4 -16-02 Not Approved (attach comments) ❑ DATE: 3 - CJ Z . Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Project Name/Tenant: uN1-L A■1 0012) t'QL- 1 4(5^ 0 .f. UT ,.:4"./..%A. D'�AGE :11t;r�x ;a: , Ti t''' i [ {; t ; „ ,F , Value of Mechanical Equipment: if 20 (5 c7 ;) Site Address : • 1 W41::) aV1;yL 1 - .s. i City State/Zip: 9la 188 Tax Parcel Number: C) 223 zc_ •— 0 0 32 Property Owner: 44 L` �WOM , d.O► -q Mt c- tj.L. -..75 Date: Phone: (-Loy.) C.x Street Address: (n t- It t z -I PZ.t V -fl , City State/Zip: 98188 Fax #: ( ) Contractor: - r=1 Ve 5 M. -cNMt l Lit..t_.. Fax #: (`l Phone: (•u"3) Fs33Z2: Street Address: , 1 3R 62_ 1.4..-_s-r- VI~t..t.- �Ww `( fJ • - 'o City State/Zip: j vF., , 90001 Fax #: (3) e ' i e :�.) Contact Person: 17-4. c_I -15•4-b lia — Csd12.c -t.1. Phone: (-Zok, ) - 765G3 - 8°Pct4- Street Address: City State/Zip: 3no y W - Vn41- `1 VW I 4 z.a r. 4.0 t3 , h1 L.. cie I Fax #: iBYUIL !1(; ' Q. L, Sign. ur • rig 0 .f. UT ,.:4"./..%A. D'�AGE :11t;r�x ;a: , Ti t''' i [ {; t ; „ ,F , ”" '` +' .. . ,. -a :: "` ' . 1 . i`S,Ir�i Date: Print name: .A� la � 12_ C- �.YL -U� Phone: ( �-i se e,Pi Fax #: (`l 3) , ,ri-e, Address: �sMl5<« City / State/Zip: CITY OF TL '14/ILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. � d A I.Y. Wt IA ArZN�ii A� �i.„�:�r..y, t..; ..i� ;NE � -y [ I }� 1 Y n i'..: v „e:. �,,•ywi�. >.� ;�.�.. u '. �� r 'o N+s� „ ,,.. meopo� L p itorat etvio D APPRQVxili QUESTED:.lb!BE;F eab;ei.a Y•'APPLICAN. Description of work to be done (please be specific): WEP LI LE 1i?•c'o F TO 1�.GY --�G J t j t'TS . vs)/ '7 6 E. Ut1 v"T” • gvas..-c PoH I Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY 9F PERJg1QY BY THE LAWS OF T f(E STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 3 73•0■ 11/2/99 ',tech perndtdoc Date application expires: Application taken by: (initials) V Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -15 . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut - off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal 9/21/99 nslscpmLdoc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence I Heat loss calculations with specifications or Form H - 6. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223200032 Address: 340 ANDOVER PK E TUKW Suite No: Tenant: HALLWOOD REAL ESTATE PERMIT CONDITIONS 1 Permit Number: MO2 -050 Status: ISSUED Applied Date: 03/13/2002 Issue Date: 04/01/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 13: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 14: Duct detectors shall send a supervisory signal only upon activation. 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 17: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 18: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Chief 53. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions MO2 -050 Printed: 04 -01 -20(2 00 co cn W uj o LL Q` cn O W uj 3 p U ON OH wW l!! U cA O 1 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating cons ruc ion or the er rman of work. Signature: Date: Print Name:(,} -Usg2) MO2 -050 Printed: 04 -01 -2002 • Receipt No.: R020000426 Initials: KAS User ID: 1684 TRANSACTION LIST: ACCOUNT ITEM LIST: City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 , Parcel No.: 0223200032 Permit Number: MO2 -050 Address: 340 ANDOVER PK E TUKW Status: APPROVED Suite No: Applied Date: 03/13/2002 Applicant: HALLWOOD REAL ESTATE Issue Date: Payee: FIVE STAR MECHANICAL Current Pmts Amount MECHANICAL - NONRES PLAN CHECK - NONRES Type RECEIPT Method Description Payment Amount: 242.44 Payment Check 11533 242.44 Description Account Code 000/322.100 193.95 000/345.830 48.49 Payment Date: 04/01/2002 01:43 PM Balance: $0.00 Total: 242.44 ?4 34/02 9710 TOTAL 242.44 doc: Receipt Printed: 04 -01 -2002 ce IL/ C) 8 2w W O . u. d : 1111 j U0 O N 0 H WW V , U. z : N . O INSPECTION RECO', - I Retian a copy with permit INSPECTION N0.. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Type of Inspection: 4-\\ble sivove SLA-Adt.,„ Date Called: Proje ■ v....c : Y )4' ( Address: . A ' ikcov 0 . ?1) Special Instructions; Date Wanted: a.m. P.m. Requester: -- Phone No: COMMENTS: mo tc4P CsAbr S ri- - pprov e ifn-t Caw 014 k OV--• 't ( • . : Approved per applicable codes. Corrections required prior to approval. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be , paid at b300 Southcenter Blvd., Suite 100. Call to scheduleeinspection. r eceipt 'Date: - N A: 4- 0: fxy /VD O 6-13 eirr (206)431-3670 INSPECTION Approved per applicable codes. INSPECTION RECO Retairi:a copy with permi ITY •OF: TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 20.6)431 -3670 Project: -2` Addre s: t;;;:: : . Specia Instructions: Type of Insp 1 gelAr. 54,"4,..,r Date Called: Date Wante�� p. m. Requester: Phone No: COMMENT tc%////aea Corrections required prior to approval. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 1300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: w U 9 w Z W O tu np U ON 0 $- w W u. W Z = . O �- NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. Pr j ct: =Ha /IGVO ( Tyne of Ins ection: 5 0-d 1114 - 1- - n - A1' 0 / !'er Pk._ E DatgJtar a O Special Instructions: �!1'1 I 1 ✓ /047/1 Date Via ted: 6.7i. a3 /OR Requ r: Phone No:_ — 7M- n /Y INSPECTION RECOU Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION '6300Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. MENTS: eceipt No.: !Date: r• . (Date• 7.00 REINSPECTION F E REQUIRED. Prio to inspection, fee must be paid at $300 Southcenter Blvd., Suite 100. all to schedule reinspection. Pl - .41 Sx ' : % ;i 1,.. 4f. � Projegt a J Type of IAsp c io - / . _ Address: d / APE nE Date called: _ va J� Special instructions: I Date wanted: /� 5^ .3 �a a.m p.m. Reque er: giala4 GU Phon � 8 15 INSPECTION NO. INSPECTION RECOR Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 MOO -o0 PERMIT NO. 1 * (206)431 -3670 COM ENTS: Inspecto( J J r A „ Date: fJ $47 0 R SP 0 r ' EQUIRk Prior to inspection, fee must be paid at 63 Southcenter Blvd 'Suite 100. Call to schedule reinspection. Receipt No: Date: Approved per applicable codes. fl Corrections required prior to approval. 'Authorized Signature FINALAPP.FRM City of Tukwila Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name ]r:' // � //e A• Address 4 i Approved without correction notice Sprinklers: - - Firer' "Alarm: Hood & Duct: /' Halon: I Monitor: (2,,.. /Ark/ ;T Pre -Fire: r% Permits: e/( Rev. 2/19/98 �!l7 Retain current inspection schedule Needs shift inspection t- / 14- i Approved with correction notice issued Steven M. Mullet, Mayor Permit No. /• // �-" Suite # `%/ Sj/ v 2 Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206. 575 -4439 H�► • e^ iIlrr4nrc. +--ri • FILE COPY SEP P, OLECTRI ePLUNIBI 1G d GAS CITY Of TUKWILA BUILDING D1a1SlCN 340 Andover Park East Tukwila Washington 98188 CITY Of TUKWILA APPROVED MAR 2 9 2002 !t}1LD$ G DiVTsK Documentation of Existing HVAC Units ts and Installation RECEIVED CITY OF TUKWILA MAR 1 3 2002 PERMIT CENTER Modal No. CHM1- 511.513 CHI48461.653 -- Total tCoaoling Capacity Aft! Certified capacity l8tuhl ' 49,000 Total unit watts 7400 _59.000 BB00 Dehumidifying capacity 23% 26% Blower wheel nuns diary x wed. firm.) (21 10 x 6 (21 10 a 6 Blower Motor hµ 112 1/2 Refrigerant (R -221 thorns I 8 lbs. 12 of 8 lbs. 11 o:. Condenser Coil Net face area (W. ft.) I 695 8.33 1/2 Tube diant in, i >tlo. 01 rows I 1 -3 Fins pm inch 13 13 Condenser Fan Diary (in.) & No. of blades Air volume (factory setiirrip Motor hp I 1 26 -5 26 -5 4100 4320 112 1/2 670 Motor watts (facto setti 670 Evaporr ator Coil Net face area Igi. hi 1 3.75 4.58 Tubediarr. fin.) 8 No. ottiows i 1/2 -4 1/2-4 Fins par inch I 10 10 11No.4 Condansiiia driin sir Nat weight of basic T.._� iAT' (in,i I I �� 111161ax31 -112x1 (1) 16112 x 27 -7/8 x 1 314 (1)16.112 a 31.1/2 a1 (I) 16-1/2 x 27.7/8 3/4 units fibs) I1•Pk .1 I 770 i 800 Optional Duct Enclosure (Without Power Saver) j R78-65-'229 lbs. Optional Duct Enclosure with Power Sever 8 Controls installed R(J8 -65 - •360 lbs. RMF365 - • 100 lbs Oita eel Rod Moun optional Minimum Woal And Return Step lin Frae m Fresh Air Damper OAD3.65 - •7 lbs. Ceiling Supply Owen Diffuser RTO 65 - '52161. Optional Combination .Ceiling Supply And Return Flints Diffuser FO-66 - '26 lbs. J "F0.66.0 - '33 lbs. Comburulon Supply Return Air Duct & IRTD Diffuse r495.92 '36 the. FD Dif fusor I r •" Mar 12 02 03:29p Pam Whitelam t tCleanable pohrurotharrafMan media. *Nat weight • • Flurl,.4l(fusor with adluttsblabeffle SPECIFICATIONS. 253 - 072 -4613 p.2 VNOTE -Rated in eccordapr:e.wth ARt titaed*if.210:460dmwt pastor. eb.y olumanorton eS oolitlitcapechy .M5F andoorrr.aolls"swfo. „ 60dbl 67ials. enter.Ingt+eanorator:Mr. _ • RATINGS Unit Entering Wet Modal MAW No. Degrees Evaporator Air 80F Dry Beth i (FI Total Air Volum, (Clint 1600 1800 2000 51.200 .87 5430 46900 .91 52.700 .88 5510 48.700 .92 54.000 .B9 5590 � 49,800 .94 • .72 5670 .76 5730 .54 5800 .55 5860 .56 5910 .85 0670 .87 6670 .90 6740 .71 5760 .72 6830 .73 6900 .53 6900 .56 6970 .56 7040 300 Outdoor Air Temperature Entering Condenser iF) $5 95 105 113 Total SoosiMM Comp. Total Swwible Comp. Told Sensible Comp. Toth Sensible Coding To Total Motor Coding To Total Motor Cooling To Tone Motor tooling To Total Capacity Ratio Input Capacity Raba leprt !apardy Ratio legit Capacity Ratio Misfit) (VT) Watts ( (smolt) (S/T) Watts i (Bhlh) 15171 Netts 1Btuf11 ISR) 54, 67 1800 55,500 2000 54600 1600 57.800 71 1800 68,900 2000 59,800 2000 68.600 63 2250 6a 2500 61.700 2000 61,800 67 2250 63.500 2500 64.700 2000 64,800 71 2250 66.100 2500 67.300 .73 51.300 .76 \. 5990 52.300 .79 6060 54 000 .56 6170 i.T. .% I \1 55.100 .57 6260 56.400 .59 6330 55,000 .88 6950 57,200 .90 7080 58.700 .92 7170 59.100 .73 7190 60 .74 7290 62,200 .75 7370 62.200 .54 7370 63,500 .56 7450 64.900 .57 7530 6480 43.500 .86 6660 1 46.500 . 6740 i 47,600 .61 5690 43,000 .94 6100 38.900 • 97 5820 44,800 .96 6230 1 40.400 .99 5890 44000 .98 6320 1 41.500 1.00 00 1, 47.200 .79 , 6420 1 42.300 .85 48.000 .82 50 .. .57 51,500 I .69 52,800 .61 6830 1 48.400 .63 Motor lrput Vtotts 6430 6560 6660 49.800 52:000 .92 7240 a 44,200 .94 7380 1 48.500 54.100 ( .96 7520 i 48.800 1.00 54.200 ' .75 7520 1 48900 56.100 .77 7660 51,100 .78 .79 57.700 .78 7760 ! 52.800 .81 57.600 .56 7760 1 52800 , .57 59,200 .57 7860 1 54.300 .58 61.000 .56 7980 58200 .60 0750 • 6820 "t ``iYi. 7080 Vii" •a•• 7160 Tri; 7240 z;' • `': 7670 ••`2 7830 8000. 8000 y =` 8170 �+ 8300 8300 • 5410 :' s 8520 �...'n '••' :: :•4^?! 1;.i iirr�:i::..: • ••. °' A � ' .i.7. �,J.�,1.: ... .. • .•.• >:.:iC.w'i . k1'• �, m "' �L'r : . - i C• � i? . • 'ti •2f t .A G.., .:tx �:�: .. ;�! i: i' Pr7; 0.•(•: S.b 1. •. �• :.: •=1? t•fY, ?' y Ii` 1'•. • • tJ:•..... •• i,ii '. :Ta•'. ]'r,,,l i.l.y_.. .T..;, 7• �'• ..i.a..h .... ,.'(::. .�x ,V.,•1' I'C.�f.M1W!n.�tttlmtM{ :i v :( j iy 5 l �AA": ? F,•' / ,'�l� ' ; + = fi t . t tiw�1'.i ! .:1� '441;96"0` 1 :Z•rsa� CLi 2, Mar- 12 02 03:29p Pam Whitolam ►-, j L y''a J1 �V. • • 1 �f. r✓; Condensate drain site MPT (in.) i', al '.; ' r,;1 ir 'Y tot rY 51 Ci •Coding Capacity. Total @AR1 Standard Conditions Refrigerant charge 111 22) Blower wheel nom. diem. x Arid. (in.) Blower Motor Hp See Drive Selection Table Condenser Coil Condenser Fan Evaporator Coil No. & site o1 filters (in.) Nat wei • ht of basic unit lbs. Unit Model No. CH A8.1353 CHAS' 1853 63 67 71 63 67 71 63 CHA8.2753 67 71 • • Model No. Total unit watts Dehumidifying capacity Minimum Maximum Net face area Isq. 1t.1 Tube diam. (in.) & No. of rows Fins per inch Diem. (in.) & No. of blades Air volume (cfml Motor Watts input (to0111 Net face area Tube diam. (in.) & No. of rows Fins per inch Evaporator Air SOF • Seib Entering Wet Bulb Degrees (F) capacity 1Btuh) hp 4950 5500 4400 138.000 .87 139.000 .90 143.000 .71 4950 5500 4400 4950 5500 6000 6750 7500 6000 6750 7500 6000 6750 7500 8800 145.000 146,000 150.000 152,000 155.000 191.600 195.500 199,100 _ 206.600 210.900 214.900 222.200 226,400 230.400 261.000 .73 .76 .58 .60 .62 .84 .87 .89 .67 .69 .71 .52 .53 .54 .89 12.300 12.400 12,600 12,800 12,900 13,000 13.200 13.300 17,000 17.100 17.300 17.800 18.000 18, 200 18.600 18,900 19.100 25.100 131.000 133.000 136,000 138.000 140,000 143,000 146.000 148.000 181,400 185.000 188.300 195.800 199.800 203,400 210.600 214,500 218.100 248.000 .90 .93 .72 .75 .77 .59 .61 .63 88 .90 .92 .69 .71 .72 .53 .54 .55 .92 9900 , 95.000 10,000"' 96.000 10,100 98,000 10.300 102.000 10.400 104,000 10,500 105,000 12 900'E 123 000 13.000 ( 125.000 13,200 1 126.000 13.400 1 129.000 13,500 131.000 13,600 133.000 13,800 1 136,000 14.0001 138,000 14,2001 141,000 18,4001 170.800 18.600 1 174.000 18,800 l 177,100 19.300 184.600 19.5001 188,200 19.700 191,300 20.2001 198,300 20.400 i 201.800 20.600 ' 205.000 26,600 235.000 .77 .78 .80 .59 .60 .61 .89 .92 .96 .74 10,700 10,800 10.900 11.200 11.3130 11.400 13 800 14,000 14.200 .77 .80 .61 .63 .64 .90 .93 .95 .71 .73 74 .54 .55 .56 .94 14.300 14,400 14,600 14,700 14,800 19.900 20.100 20,300 20,800 21,000 21.200 21.600 22.000 22,000 28.100 89.000 91.000 92.000 96,000 98.000 100.000 115 000 117.000 118,000 121 000 123.000 125.000 127.000 129.000 131,000 160.100 162.900 165.700 173,100 176.300 179,200 186,100 189,100 192,000 222.000 .78 .80 .83 .60 61 .62 .92 .96 1. 00 .77 11.600 11.800 11.900 12,100 12,200 12.300 14 800 15.000 15,100 .15,300 .80 .82 .63 .65 .67 .93 .96 .98 .73 .75 .76 .55 .56 56 .98 15,500 15.700 15.800 15.900 21.300 21,500 21 600 22.200 22.400 22,600 23.000 23.200 23.500 30.000 15.400 Total Air Volume (Clio) (sq. ft.) 63 3375 100,000 CHAS 953 I 67 3375 108.000 71 3375 115,000 4400 9900 85 Total Sensible Cooling to Total Capacity Ratio if/Rohl (S(T) 3000 98,000 3750 102.000 3000 106.000 3750 109,000 3000 113.000 3750 117,000 135 000 266,500 8800 282.600 9900 288,500 8800 304.500 9900 309.800 • }r f 4, j I: i ".•ri �: Q0.,,,.. .1zz lzr .vr...wc�mro;. rr :.J ,'. •n�.1:n arm:F ,. i• .91 .58 .84 .92 54 .55 Comp. Motor Watts Input 12 200 25,300 27.300 27.600 i'i'i: • CHAS-953 196.000 I t 130,000 12,700 269E 16 lbs. 12) - 12 x 6 ( 121-15x9 121 22- 5 2 3 10.2 303- 4 18 5000 (21 112 1100 7.4 318 - - 13 11)20x25s1 ) 16 x 25 x 1 1425 Outdoor Air Ten+peretwe Entering Condenser (F) Total Cooling "ty ((kohl 8900 93,000 .93 9000 95.000 .97 9100 96, 000 .73 9300 100.000 .75 9400 102.000 76 9500 104,000 .57 9700 107,000 .57 9800 109,000 129 000 252.500 288.000 292.600 95 Sensible to Total Retie (SITI .98 1.00 .74 76 .77 .58 .58 9900 111,000 .59 .86 .96 .55 .56 CHAS -1353 9700 17,100 28% 17 lbs. 3 5 13.8 3(8 -4 18 12) 22 - 5 7550 (21 314 1640 9.4 318 -4 13 16) 16 x 20 x 1 1860 Comp. Total Sensible Motor Cooling to Total Watts Capacity Ratio btout� Muhl (T .94 9500 88,000 .96 9600 89.000 1.00 91.000 26.800 i 239,200 3- 872 -4613 •1s 1:�:R:p7g 4. 105 1.00 • CHAR -1853 200,000 25.000 29% 40 lbs. (2)- 15 x 11 3 5 (2) 10.75 ea. 112 - 4 13 (21 25.112 - 13,500 (2) 1 2820 (2) 7.67 ea 112 -4 13 (4) 20 x 20 x 1 (4) 16 x 20 x 1 1 -1(4 785 P• x�� CHAS -2753 273,000 35,500 26% 48 lbs. ?. 5 ; (2) - 15 x 15 7.1/2 (2) 12.15 ea. 112 -6 13 (21 25.112 - 13.250 (2) 1 2500 (21 8.75 ea. 112 -4 181 20 x 20 x 1 3280 • s 4 : •r ,c{ra - r'�o ... ..a t r s+n!iert w c,"x7 o lr •4'• - i...'.yar?71 .. ;;,. t • �:y l °�,{,iµt .0 ]�4 ki,^ 71 :", ;lV : .A i1f,4 ' "v •, ' " t r ;� . l 't . !;. ?,' i�r.k�f�' " / . +Q , - y ,-'i 1 • 1T � i f s ` ! x ` 71 } ~ ' t 1 f.. :-iN fsil t i .i' c``1'I d ? :r �•a:b f .,. "1 ".•Y<T Comp. Motor Watts lnout 10,400 Total Coolitg pty (Stahl 10,200 1 83.000 10,300 ( 84.000 86.000 .97 28,400 225.500 1 00 70 26.000 268.000 .72 27.1130 254,000 .73 26.400 273.000 .75 28,000] 268,000 .76 29.700 242.700 .78 .74 29.400 239.400 .76 29,0001272,000 .56 30,800 255,800 .58 29 300276,000 .58 31.200 259.500 .59 'S .1 � 11 �F.. %�' 1�, i,•,.i .err rR.F' f: } • � 'ba:�,�7 ; �'.'���4'h.iki�' � rt7�._'s(,i* '� i:F�ti r° l i� >�i.��' ,,.' 1 : i 'i ' v..q. v :.'•.;tbdi.', {��( 115 nsble Comp. to Total Motor Ratio Watts ISin hoot 1.00 11,200 1.00 11.300 1.00 11 400 30,300 31.500 s∎• k•J., 31.800 32,900 33,200 k : : T 1 I;. , "S.1' ir".4.0 •^. •I'his is a typical picture of the 5-ton units. is [his is a picture of the 7 H-ton unit -k span lain Ileams.T z Z W IX 2 --I 0 00 U) 0 CJ) W u_ u j 0 Ce -7 u_ < ° Z F- 1— 0 Z LU u 0 (1) 0 1— UJ u j 1— r - u_ 0 Z (I) o 1- z New Trane 7 ton unit weight = Weight Comparison Existing Lennox 7 ton unit weight = Existing Lennox 5 ton unit weight = New Trane 5 ton unit weight = 820 lbs. 522 lbs. 1425 lbs. 800 lbs. REQUIRED POR: c HANIC /4L arro LUMBING _ LECrRICCL VG S PIPING 801 Ll�i TUKWILA DIVISION Packaged Gas/Electric Rooftop units Precedentrm 3- 10Tons -60 Hz 2nd Rep October 2001 F 2002 CITY OF TUKV&A APPROVED MAR 2 9 2002 tis W) FED lat/21 MA LD 4G DTiR5t 1 RECEIVED CITY OF TUKWILA MAR 1 3 2002 PERMIT CENTEP RT- PR0006•EN MO 2 050 qr;.... ;.:u;:': }•:i �.: - ..'F +.`;; >. r� t' i9�t, C> i• 193�a'.: 7t3rt: rsz:. vtat 4+ raarv. .s ;*Citi 4444 r i7i�ss:X4} i 4>: ‘.Q k o4i,� �vbskl` Table G -G Coaling Piar1annonos' Gross Cooling Capacity 63,100 63,100 72.000 SEER/EER' 9.9d- 10.20/- -/10.2" Nominal CFM /ARI Rated CFM 2,000/2,000 2,0002,000 2,400/2,100 ARI Net Cooling Capacity 60 ,000 60,000 69,000 Integrated Part Load Value' - - - System Povver(KW) 6.86 6.78 6.77 Mating Partonnonot Heating Models Low Medium High Low Medium High Low Medium High Heating Input (Btu) 60,000 80,000 130,000 60,000 80,000 130,000 80,000 120,000 150,000 Heating Output (Btu) 47,000 63,000 103,000 48,000 64,000 104,000 64,800 97,200 121,500 AFUE 96 81 81 80 81 81 80 81 81 81 Steady State Efficiency (96) 81 81 80 81 81 80 81 81 81 No. Burners 2 2 3 2 2 3 2 3 3 No. Stages 1 1 1 1 1 1 1 1 2 Gas Connection Pipe Size (in.) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 PfoJType 1/Climatuff Scroll 1 /Climatuff Scroll 1 /Climatuff Scroll Outdoor Sound Rating (dB)° 83 83 90 Outdoor Col -Type Lanced Lanced Lanced Tube Size (in.) OD 0.3125 0.3125 0.3125 Face Area (sq ft) 8.81 8.81 13.88 Rows/FPI 2/17 2/17 2/17 Indoor Cog -Type Lanced Lanced Lanced Tube Size (in.) 0.3125 0.3125 0.3125 Face Area (sq ft) 5.00 5.00 9.89 Rows/FPI 3/16 3/16 2/16 Refrigerant Control Short Orifice Short Orifice Short Orifice Drain Connection No./Size (in.) 1/3/4 NPT 1/3/4 NPT 1/3/4 NPT Outdoor Fan -Type Propeller Propeller Propeller No. UsediDiameter On.) 1/22 1/22 1/26 DriveType/No. Speeds Direct/1 Direct/1 Direct/1 CFM 3,470 3,470 No. Motors/HP 1/0.33 1/0.33 1/0.70 Motor RPM 1075 1,075 1,075 Divot Oran Indoor Fan -Type FC Centrifugal FC Centrifugal N/A No. Used Diameter (in.) 1/11 x11° 1/11 x 11° N/A DrlveType/No. Speeds Direct/2 Direct/2 N/A No. Motors 1 1 N/A Motor HP (Standard/Oversized) 0.90/1.00 0.90/1.00 N/A Motor RPM (Standard/Oversized) 985/1,08(? 985/1,08CP N/A Motor Frame Size ( Standard/Oversized) 48/48 48/48 N/A Rolf Dram Indoor Fan -Type - FC Centrifugal FC Centrifugal No. Used/Diameter (in.) - 1/11 x 11 1/12 x 12 DriveType/No. Speeds - BeltNariable Sheave BeltNariable Sheave No. Motors - 1 1 Motor HP (Standard/Oversized) - 1.001- 1.00/2.00 Motor RPM ( Standard/Oversized) - 1,750/- 1,750/1,750 Motor Frame Size (Standard/Oversized) - 48/- 56/56 FRtars -type Furnished " Throwaway Throwaway Throwaway (No.) Sian Recommended (2) 20 x 25 x V° (2) 20 x 25x V' (4)16 x 25 x 2 MN1jMant Chugs (Lbs of R -22)' 4.9 4.9 7.1 NOTES: 1-7. See Not on Page 12. a YSC06OA Oversized Motor Fan Diameter is 12 x 11. 9. Alter RPM shown is low speed. High speed RPM is 1100 /1135. 10.FAter size shown Is for low and medium heat models. High heat model filter size recommended Is 20 x 30 x 1. 11.0ptional 2" pleated filters also available. 12.YSC072A when used In a horizontal application has an EER of 10.1 and System Power (kW) of 6.93. RT•PRC006 -EN YSC060A1 41) MANE* General Data Standard Efficiency 5 -Ton Convertible 6 -Ton Convertible YSC060A3, A4, AW YSC072A3, A4, AW 13 > a Grua - canaralara Coaling Prrfonnenoat Gross Cooling Capacity EER Nominal CFM /ARI Rated CFM ARI Net Cooling Capacity Integrated Part Load Value' System Power (KW) Heating Prrlmmmoo' Heating Models Heating Input (Btu) Heating Output (btu) AFUE % Steady State Efficiency ( %) No. Burners No. Stages Gas Connection Pipe Size (in.) ype ar Outdoor Sound Rating (dB)° Outdoor Cots -Type Tube Size (in.) OD Face Area (sq R) Rows/FPI Indoor Cod -Type Tube Size (in.) Face Area (sq ft) Rows/FPI Refrigerant Control Drain Connection NOJSize (in.) Outdoor Fan -Type No. Used/Diameter (in.) DriveType/No. Speeds CFM No. Motors/HP Motor RPM ■ eit Drive Wear Fan -Type No. Used/Diameter (in.) DriveTypelNo. Speeds No. Motors Motor HP (Standard/Oversized) Motor RPM (Standard/Oversized) Motor Frame Size (Standard/Oversized) Mere -lype Furnished n (No.) Size Recommended Refrigerant Chew (Lbs of R -22)' 14 Low 120,000 97,200 81 81 3 1 1/2 Single Compressor YSC090A3, A4, AW 95,000 10.1° 3,000/2,625 90,000' 8.91' Medium 150,000 121,500 81 81 3 2 3/4 1/Trane 3.D Scroll 90 Lanced 0.3125 17.0 3/17 Lanced 0.3125 9.89 3/16 Short Orifice 1/3'4 NPT Propeller 1/26 Direct/1 1/0.70 1075 FC Centrifugal 1/12 x 12 BelWariabie Sheave 1 2.00/3.00 1,750/1,750 56/56 Throwaway (4)16x25x2 11.9 General Data High 200,000 162000 81 80 4 2 3/4 73/4-Ton Convertible Low 120,000 97,200 81 81 3 1 1/2 Dual Compressor YSC092A3, A4, AW 92,000 10.4' 3,000/2,625 8Z000 11.0° 8.37 Medium 150,000 121,500 81 81 3 2 3/4 2/Climatuff Scrolls 90 Lanced 0.3125 17.0 2/17 Lanced 0.3125 9.89 3/16 Short Orifice 1 /34 NPT Propeller 1/26 Direct/1 1/0.70 1,075 FC Centrifugal 1/12x12 BeltNariable Sheave 1 2.00/3.00 1,750/1,750 56/56 Throwaway (4)16x25x2 6.2 Circuit 1/3.4 Circuit 2 NOTES: 1.7. See Notes an Page 15. 8. YSC090A %ten applied in a horizontal configuration is 10.1 EER, and 8.91 System Power (KW). 9. YSC092A when applied in a horizontal configuration has a 10.1 EER, 10.7 Integrated Part Load Value, and 8.61 System Power (KW). 10.YSC102A when applied in horizontal configuration has an 11.3 Integrated Part Load Value, 9.8 System Power (KW) and 99,000 ARI Net Cooling Capacity. 11.Optional 2" pleated niters also available. (71/2 w 81T ) Standard Efficiency High 200,000 162000 81 80 4 2 3/4 83/4-Ton Convertible YSC102A3,A4,AW 105,000 10.110 3,400/3,000 100,000 11.8 9.9 Low Medium High 120,000 150,000 200,000 97,200 121,500 162000 81 81 81 81 81 81 3 3 4 1 2 2 112 3/4 3/4 2/Climatuff Scrolls 92 Lanced 0.3125 19.83 2/17 Lanced 0.3125 12.36 3(16 Short Orifice 1/3'4 NPT Propeller 1/26 Direct/1 1/0.70 1,075 FC Centrifugal 1 /12x12 BelWariable Sheave 1 2.00/3.00 1,750/1,750 56/56 Throwaway (4)20x25x2 7.9 Circuit 1/3.7 Circuit 2 RT- PRC006 -EN • z r w UO N 0 • u_ WO 2 g co ? F- W U � O 0 I- W W, W Z O All dimensions are in inches. 3-71sns — DownicwAMow Supply and limn flaougn the Base Utilities 3-Mtn — Unit Mann= and Roof Opening 72 34 Tcns — Horizontal Meow Supply and Return Dimensional Data 6761.1 106 00 AIM CLEARANCE 3T (IMO MM) ,• _ L .v.• J ,6,rr 66an 23! L.4 au,w — r9 . 5•rat. (3 - % Tons) THROU9�� E SUPPLY 17 1/4• 67 436MM '"225MM 3/4.14 NPT CONDENSATE DRAIN THROUGH WE BASE AL TYPICAL ROOF OPENING RETURN (10, MM) \� � > 663'16' 0 (,7ffi MIA) � 9140 6•41 I4• 23 /4• 591MM 311 t 1 ' 5I&l 3 3/16' 61MM — 3/4' 121MM 7MM 337MM CLEARANCE iipph HORIZONTAL FLOW • 16' (457 MM) DOWNFLOW 36'1514 MM) CLEARANCE 46' (1218 MM) CLEARANCE 39' (914 MM) RT PRC006.EN z re W 0 0 CO 0 N u_ W W d F- 0 Z 1- W uj 0 0 I- ili uj — O U OF" z ) All dimensions are in inches /millimeters. 6.10Tars —Dawn lowAirAowSupplyand 7lrnugh the Base Utilities 0-10bns —Hw an aiMiowSuppyandRerun 8.117Tone — Unit Mamma and Roof Opening RT- PR0006•EN Dimensional Data 104 32 T 11611M AM SW ( MM) (1 161 MM) 225 CLEARANCE 48' (1219 MM) RETURN 7 01 w CLEARANCE 38' (914 MM) o • 771W - 1 Toffs) SUPPL S1' 676 MM MU CONDENSATE s l� 1 »w ROUG THE 3 11414 NPT LM HOLE CONDENSATE DRAIN 40 4. 10151.01 TNROIR0N ELECTRICAL — .^ 1111 . 1 10 71 276w TYPICAL ROOF OPENING 46' / \ (1168 MM) / i ce 53 114 25 71 MM CLEARANCE iipik HORIZONTAL FLOW • 18' (457 MM) DOWNFLOW 35' (914 MM) / (1352 MM) CLEARANCE 36' (914 MM) f 61? 113/01 75 . :.- ti',.�.. _;,.:_:,,i.w.:ar..:,axbb.ai.. .:.:a...:�<usuu:•:M.,. A..:. z 1 ix W 00 N 0 W co u. WO u N a W 0 O N 0 I— WW H u. O il Z 0- O I.. z Title NR1— Marinun Unit And ComerI W N.S (Lbs1And it Of Gravity Dimensions (4t) Tons 3 4 5 6 834 10 Unit Maximum Weights (Lbs)t Corner Vsbights (Lhs)1 Center of Gravity (In.) Model No. Shipping Net A 8 C D Length Width YSCO38A YHCO36A YSC048A YHC048A YSC060A YHC060A YSC072A YHC072A YSC090A YSC092A YHC092A YSC102A YHC102A YSC120A YHC120A NOTE: 1. Corner weights are given for information only. 2. Weights are approximate. RT- PRC006•EN Weights 534 480 151 124 96 109 32 19 551 497 158 128 101 110 32 19 559 505 159 130 108 109 33 19 593 `__ 166 133 114 126 32 20 576 `57Z/ 169 134 105 114 32 18 628 574 179 140 119 136 32 20 822 735 249 193 132 161 39 21 859 7 249 198 141 184 39 22 907 820 273 208 146 193 38 22 909 277 222 147 175 40 21 1010 923 306 243 165 210 39 22 986 899 297 243 165 194 40 21 1044 957 310 252 175 220 40 22 1074 987 325 265 183 213 40 21 1147 1060 342 277 197 245 40 22 CENTER OF GRAVITY WIDTH D CENTER OF GRAVITY CENTER OF GRAVITY LENGTH Tithe 4K2 — Factr y4nstWJed Options Net Weights (WW Accessory Economizer Barometric Relief Powered Exhaust • MINE* Net Weight 3.5Tons 6 -10Tons 26 36 7 10 80 Motorized Outside Air Damper 20 30 Manual Outside Air Damper 16 26 Roof Curb 70 115 Oversized Motor 5 8 Belt Drive Motor 31 — Smoke Detector, Return 7 7 Smoke Detector; Supply 5 5 Coil Guards 12 20 Hinged Doors 10 12 Powered Convenience Outlet 38 38 Through the Base Electrical 8 13 Through the Base Gas 5 5 Unit Mounted Circuit Breaker 5 5 Unit Mounted Disconnect 5 5 Novar Control 8 8 NOTES: 1.Welghts for options not listed are >5 lbs. 2.Net weight should be added to unit weight when ordering factoryinstalled accessories. 79 nvrmM.+ r... n.. e...+.+..,.-.•.....- �...,..- .....,vv.�.....«�.'m..�.aar`+n .. .xa�uwn.nw��« eau+ fn�nm.�n«n�F�R.Qq'!tn'�.Vii" ei rY 0.7.7 j • WI TR NE Package Gas/ Electric Units Convertible Models YCC018 -060F 1 -1/2 5 Ton 0 American Standaid lnc. 1992 YC -D -9 FILE C'Onv Gip( (NA 1 i IKW$l._A ApoN'Ti t D MPR 29 21' z ~ • W O 0 w= W • O 2 � a w _ Z �. I— O Z I— w � • p U 0- O f— ill F— LO .. z W U = O • 1— z General Data ■ • MODEL YCC0ISF1LOB YCC GB YCCO30FILOB YCCO30F1MOB RATED VOLTS /PH /HZ 208- 230/1/60 208 -2 /1/60 208- 230/1/60 208- 230/1/60 A.R.I. RATINGS (COOLING)® BTUH 18000 23400 29200 29800 Indoor Air Flow (CFM) 600 800 1000 1000 System Power (KW) 1.93 2.55 3.11 3.27 EER /SEER (BTU/WATT -HR.) 9.35 / 10.00 9.10 / 10.00 9.20 / 10.00 9.10 / 10.00 Noise Rating No. 8.0 8.0 8.0 8.0 A.G.A. RATINGS (HEATING)® (High) Input BTUH 50000 50000 50000 75000 A C Capacity BTUHOO 7 400 400 %0 408 00 60000 Temp. Rise °F (Min./Max.) 30 / 60 30 / 60 30 / 60 35 / 65 (Law) Input BTUH 40(100 40000 40000 60000 BTUHOO 32000 32000 32000 48000 AFUE/CSE 78 %/76% 78 %/76% 78 %/76% 78 %/76% Temp. Rise °F (Min. /Max.) 30 - 60 30 - 60 30 - 60 35 - 65 Type of Gast NATURAL NATURAL NATURAL NATURAL POWER CONNS. - V/PH/HZ 208 - 230/1/60 208- 230/1/60 208- 230/1/60 208 - 230/1/60 Min. Brch. Cir. 13.2 15.7 20.1 21.3 Br. Cir. - Max. ( 20 25 30 35 Prot. Rtg. - Recmd. (Amps) 20 25 30 35 COMPRESSOR CUMATUFF'" CLIMATUFP" CLIMATUFF'" CUMATUFF'" No. Used 1 1 1 1 Volts /PH /HZ 200- 230/1/60 200- 230/1/60 200- 230/1/60 200- 230/1/60 R.L. Amps - L.R. Amps 8.0 -48 10.0 -67 13.3 -79 13.5 -79 OUTDOOR COIL - TYPE Rows / F.P.I. Face Area (Sq. Ft.) Tube Size (in.) PLATE FIN PLATE FIN PLATE FIN PLATE FIN 2/15 2/15 2/15 2/15 4.5 4.5 5.43 5.43 3/8 COPPER 3/8 COPPER 3/8 COPPER 3/8 COPPER INDOOR COIL - TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows /F.P.I. 2/15 3/15 3/15 3/15 Face Area (Sq. Ft.) 3.25 3.25 3.25 3.96 Tube Size (in.) 3/8 COPPER 3/8 COPPER 3/8 COPPER 3/8 COPPER Refrigerant Control CAPILLARY CAPILLARY CAPILLARY CAPILLARY Drain Conn. Size (in.) 3/4" FEMALE NPT 3/4" FEMALE NPT 3/4" FEMALE NPT 3/4" FEMALE NPT Duct Connections SEE OUTLINE DRAWNG SEE OUTUNE DRAWNG SEE OUTLINE DRAWING SEE OUTLINE DRAWNG OUTDOOR FAN - TYPE PROPELLER PROPELLER PROPELLER PROPELLER No. Used / Dia. (in.) 1 / 18 1 / 18 1 / 18 1 / 18 Type Drive / No. Speeds DIRECT / 1 DIRECT / 1 DIRECT / 1 DIRECT / 1 No.Motors - HP 1 -1/5 1 -1/5 1 -1/5 1 -1/5 Motor Speed R.P.M. 1080 1080 1080 1080 Vohs /PH /HZ 200 -230/1 /60 230/1/60 230/1/60 230/1/60 F.1_ Amps - L.R. Amps 1.6 -3.3 1.6 -3.3 1.6 -3.3 1.6 -3.3 INDOOR FAN - TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Dia. x Width (in.) 9X9 9X9 9X9 10X9 1 1 1 1 Drive / (No.) DIRECT / 2 DIRECT / 2 DIRECT / 2 DIRECT / 2 No. Motors - HP 1 -1 /4 1 -1 /4 1 -1 /4 1 -1 /3 Motor Speed R.P.M. 1080 1080 1080 1080 Vohs /PH /HZ 200- 230/1/60 200 - 230/1/60 200 - 230/1/60 200 - 230/1/60 F.L. Amps - L.R. Amps 1.8/1.4 - 2.9 1.6/1.4 - 2.9 1.6/1.4 - 2.9 2.8/2.2 - 5.1 COMBUSTION FAN - TYPE CENTRIFUGAL _ CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive - Speeds (No.) DIRECT -1 DIRECT -1 DIRECT -1 DIRECT -1 Motor HP - Speed (RPM) 1/35 - 3480 1/35 - 3480 1/35 - 3480 1/35 - 3480 Vohs /PH /HZ 240/1/60 240/1/60 240/1/60 240/1/60 F.L. Amps 0.6 0.6 0.6 0.6 FILTER - FURNISHED? NO NO NO NO Type Recommended THROWAWAY THROWAWAY THROWAWAY THROWAWAY Min. Face Area -Lo (ft.) ®O 2.0 2.67 3.33 3.33 REFRIGERANT Charge (lbs. of R -22)0 GAS PIPE SIZE (IN.) DIMENSIONS Crated (in.) Uncrated WEIGHT Shipping (lbs.) / Net (lbs.) See notes on page 14 8 3.8 lbs. 4.0 lbs. 4.4 lbs. 4.5 lbs. 1/2" 1/2" 1/2" 1/2" HXWXD HXWXD HXWXD HXWXD 31 -1/4 X 38 X 57 31 -1/4 X 38 X 57 31 -1/4 X 38 X 57 35 -1/4 X 38 X 57 SEE OUTLINE DRAWNG SEE OUTLINE DRAWNG SEE OUTLINE DRAWING SEE OUTLINE DRAWING 341 / 301 350/310 398 / 358 398 / 358 1 GANNET MODEL CORNER WEIGHT (IBS) UNIT WEIGHT (NETIDS.1 A B C D E F G H J II L M N P WI W2 W3 W4 YCC018F -L 68.3 61.7 84 92.9 55-1/4 36 25.3/16 18.9/16 11.1/16 6-9/16 6 -13/16 17 21.5/16 25 17-1/2 10 3 4-7/16 YCCO24U. 69.4 60.0 85 99.5 YCCO30F1 70.5 61.4 87 99.8 B YCCO36F{ 84.06 6808 92.1 113.7 358 55-1/4 36 29-3/16 18 -9/16 11.1/16 6-9/16 6-13/16 17 20-3/4 25-13/16 17.1/2 10 3 4-7/16 YCO33C1 -M 713 68.3 95.6 109.7 352 19-3/4 24-13/16 Y00036F- M 86 67.6 93.2 115.13 364 C YCCO36F -H 90.3 731 101 123.7 389 62.3/4 36 29-3/16 18-9/16 11-1/16 6-9/16 11.1/8 17 19-3/4 28.1/4 28.1/4 17.1/2 10 3 8-3/4 YCC042F -M 103.7 88.7 968 122.6 412 19.3/4 YCC041F -M 1041 146 102.2 126.4 418 19-3/4 28-1/4 D YCC048F H 123.8 104.6 132.5 157 518 64-5/16 45 33-3/8 21.1/16 15-1/16 4-15/16 9.1/8 21.15/16 25 29 1/2 20 14 3 -1/2 8.5/16 YCC060F - M 1354 109.8 1373 169.3 552 25 29-1/2 Dimensional Data 38 C K HORIZONTAL SUPPLY OPENING DOWNFL SUPPLY OPENING HORIZONTAL RETURN OPENING SECT. X -X TYPICAL CROSS SECTION OF SUPPLY & RETURN PERIMETER FLANGES YCC018 -060F Outline - Rear (ALL DIMENSIONS ARE IN INCHES) APPEARANCE SURFACE OF SUPPLY & RETURN PANEL and Weights L k 0!RENSIORAL SURFACE ISEE TABLE CONDENSATE DRAIN FOR 3 \4" FEMALE NPT DOWNFLOW RETURN OPENING SECT Y -Y TYPICAL CROSS SECTION OF DOWNFLOW SUPPLY & RETURN PERIMETER FLANGES EVAPORATOR COIL & BLOWER PANEL 1� DIA. ENTRY FOR 1/2 N.P.T. GAS CONNECTION r Dwg. 21D661690 Rev. • R25-052.000 (8/971 `1k(i4 CbL F625- 0 (#/97 DEPARTMENT OF LABOR AND INL.uSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR HVAC /RFRG LICENSE It EXP. DATE EC6A FIVESM *006C3 Q ,;/-p/ O1,? EFFECTIVE DATE :02/23/1060 FIVE•STAR MECHANICAL 3902 W VALLEY HWY N AUBURN WA 98001 DEPARTMENT OF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR GENERAL '' /'i �3i� LICENSE 0# EXP. DATE ECO1 t... FIVESM *009MA i:Ma o f io EFFECTIVE .DATE. 74:.- 04:1 '07/01 2000 FIVE STAR MECHANICAL 3902 WEST VALLEY HWY N 200 AUBURN WA 98 Alk 4s r • DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL '.# EXP. DATE CC01 FIVESM *010JT pj`iQ.p EFFECTIVE DATE ;•04 /30/1999 FIVE STAR MECHANICAL 3902 W VALLEY HWY N STE 200 AUBURN WA 98001 z • •_..c.•.:.., air:.: !. ..:i.�!xiw ( z �w 0 N0 to w LL Q zj H -O w ~ w U0 0— oI- w W H- LL' w z U= O z Marl: GP -1 GP- 2,3,7 -9 GP -6 Ma. rane mac Model YCCO24F1L013 YSC060A3RLA0051 Trane YSC090A3RLA0051 Fan Heating Heating CFM Q S.P. Speed Input Output AFUE 800 1080 40K 32K 80% 1900 C? .08 1080 60K 48K 81% 3000 1080 97K 120K 81% CONSTRUCTION NOTES AND SCOPE OF WORK 2002 Mcrosog 1999 Navreoh, 00T, C mpuseamh Gas Pack Schedule Hamm! Cooling Capacity 23 63K 90 J r 340A uv, Park E,_. Seattle, WA klIAB 1! F I; l l m E jl SEER 0 0 103 Electrical R .. 208 - 230/1/60 208 - 2103/60 208 - 230/3/60 I. Removal and disposal of six (6) Lennox rooftop units. II. Removal and disposal of one (1) Trane rooftop unit. III. Furnish and install five (5) Trane 5 -ton gas pack units with economizers and duct mounted smoke detectors. (208 /230 -three phase). IV. Fumish and install one (1) Trane 2 -ton gas pack unit with fresh air damper. (208 /230- single phase). V. Furnish and install one (1) Trane 7 '/2 -ton gas pack unit with economizer and duct mounted smoke detector. (208/230 -three phase). VI. Gas piping for above units. VII. Line and low voltage wiring connections. VIII. Hoisting. IX. Permits. X. Start and test of new equipment supplied by Five Star Mechanical. XI. One -year parts and labor warranty on equipment and material furnished by Five Star Mechanical. o - SW =41st t Or. U. MCA/ Fac-ory MAX Cerb Ec000 -mine. Outside. Damper Total Weight 15.725 NO NO YES 310# 315/50 NO YES NO 522# 42.7 /60 NO YES NO 820# Gas Package unit —1 Gas Package unit - 9 Gas Package unit — 2 Gas Package unit — 8 Gas Package unit — 3 Gas Package unit — 7 H\''AC ROOF PLAN 1/8" = 1'0" Gas Package unit - 4 INC) WORK IN THIS AREA' Gas Package unit — 5 Gas Package unit — 6 oa- 050 So 4'N 0 0 CO rn DRAWN� IY° CO CO W. CO W� 7 J n <0 W z m 00 < 0o ;Q -. 1— z 0 to DAIS 3 1.02- CHECKED PROJECT NO. 325 CONTRACT. DRWG. REF. DRAWING N0. M -1