Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M02-052 - ENCORE BROKERS
M02 -052 Encore Brokers 18251 B Cascade Av S EXPIRED OCT 16 2002 sif4 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 7888900150 Address: 18251 CASCADE AV S TUKW Suite No: Tenant: Name: ENCORE BROKERS INC Address: 18251 13 CASCADE AVE S, TUKWILA, WA Owner: Name: ESTATE OF JAMES CAMPBELL Address: C/O COLLIERS INTERNATIONAL, 20206 72ND AVE S Contact Person: Name: DOUG WALTER Address: 19405 144 AV NE, WOODINVILLE, WA Contractor: Name: WA BOTTING COMPANY Address: PO BOX 1200; STE 200, WOODINVILLE, WA Contractor License No: WABOTC *099JA DESCRIPTION OF WORK: INSTALL TYPE I COMMERCIAL KITCHEN EXHAUST HOOD AND EXHAUST SYSTEM WITH MAKE -UP AIR Value of Construction: Type of Fire Protection: Permit Center Authorized Signature: doc: Mech MECHANICAL PERMIT $5,700.00 Fees Collected: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of t is permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating co tructio or the performance of work. I am authorized to sign and obtain this mechanical permit. 7 Signature: /o�%b/ Date: ' ) 22 Print Name: (1 ( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -052 Permit Number: MO2 -052 Issue Date: 04/04/2002 Permit Expires On: 10/01/2002 Phone: (206)872 -4680 Phone: 425- 482 -9500 Phone: 206 - 364 -0340 Expiration Date: 04/01/2002 Uniform Mechnical Code Edition: Date: $ 56.00 1997 Printed: 04 -04 -2002 1 DEPARTMENTS: Building ion Public Works 5151 Approved ❑ Notation: Documents/routing slip.doc 2.28 -02 APPROVALS OR CORRECTIONS: ILL 54-6(Ap /040)1' Fire Prevention [)L Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Approved with Conditions nvca,...nrwraw Ise REVIEWER'S INITIALS: e AdOO alOOO i .iuu��d PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -052 DATE: 3 -20 -02 PROJECT NAME: ENCORE BROKERS SITE ADDRESS: 1825 B CASCADE AV S X.: Original Plan. Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued PERMIT COORD COPY Planning Division ❑ Permit Coordinator DUE DATE: 3-21-02 Not Applicable ❑ Comments: Permit. Center. Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTI G: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 4 -18-02 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 4 z 1 &I-. 00 0 w� w u. ? cS d � z F 1- Z 0— 0H W O t z 0 0 ~ Z ACTIVITY NUMBER: MO2 -052 DATE: 3 -20 -02 PROJECT NAME: ENCORE BROKERS SITE ADDRESS:; 18251 B CASCADE AV S X ; Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Comments: Permit Center (fie Only INCOMPLETE: LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Documentshouling slip.doc 2 -2802 PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: 4sA Fire Prevention Structural Incomplete ❑ Structural Review Required REVIEWER'S INITIALS: Fah Planning Division Permit Coordinator DUE DATE: 3-21-02 Not Applicable ❑ No further Review Required DATE: DUE DATE: 4 -18-02 Approved ❑ Approved with Conditions Not Approved (attach comments) U Notation: REVIEWER'S INITIALS: DATE: 3 1 Z (OZ, Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT NO.: NCO 2 `' a52 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 2 ❑ 50 ❑ 60 ❑ 610 ❑ 700 ❑ 1080 ❑- 1090 1100 1101 1102 1105 1115 1400 1800 ❑ 4015 Pre- construction WSEC Residential WA Ventilation/Indoor AQC Chimney Installation/All Types Framing Woodstove Smoke Detector Shut Off Rough -in Mechanical Mechanical Equipment/Controls Mechanical Pip/Duct Insul Underground Mech Rough -in Motor Inspection Fin - Final Mechanical - Final Special -Smoke Control System CONDITIONS 10001 No changes to plans unless approved by Bldg Div 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I 10005 All permits, insp records & approved plans available 10014 Readily accessible access to roof mounted equipment 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans 10027 Validity of Permit 10036 Manufacturers installation instructions required on site 10041 Ventilation is required for all new rooms & spaces 10042 Fuel burning appliances 10043 Appliances, which generate. Water heater shall be anchored.... Additional Conditions: TENANT NAME: C A cite. Srb44e r FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Bumer to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 clan (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm/Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add' I Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: ' 1/4 Date: 31i I Permit Tech: J ( U� Date: 01 )-1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -052 DATE: 3 -20 -02 PROJECT NAME: ENCORE BROKERS SITE ADDRESS: 18251 B CASCADE AV S . Original Plan.. Submittal Response to Incomplete Letter .# Response to Correction Letter # Revision #• After Permit Is Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 3-21-02 Complete ❑ Incomplete ❑ Comments: :Permit'CenterUse Only 'INCOMPLETE: LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire 0 Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 al Planning Division No further Review Required DUE DATE: 4-18 -02 DATE: 3/2-'7 2-- ❑ Permit Coordinator ❑ Not Applicable LI REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Project Name/Tenant: Ed C1)12.E e W 85 � � Value oMechanical Equipment: d Site Address : City State/Zip: I 77 G 04-5 6 A-UE r / A 4 8g Tax Parcel Number: 7t 8'tv - o/ — a f / w. Property Owner: f /ale. Phone: ( ) 2c6. 323- % Street Address: City State/Zip: S('2b a /4Aztr3J ,-fEA-7 LOA Fax #: ( ) Contractor: �J�}' / �//�� /A• / ,r, //�^!�/1// /rte k' A 8L,/ / �r MA d�� Phone: (y yg2 ' --,� %- Fes".V56.1 str`e gt:c t` E N.. , k9m.hatit)cu4 ZIA-1. 0'7 State/Zip: & Fax #: ( 4 y$ - // e> Contact Person. � %tJ-A-6 . -rte - GAG.im eC.�{ �; Phone: ( ) 4//4 = 4 45.2-9 - 5-. c4 Street dress: City State/Zip: 1 e 14/ & AAA -r : t U , �A 72 Fax #: ( ) 124 562- iL.% BUILDING N R'OR:AUTOR /ZGENT::r '. . Signature: / / Date: 3 _ 247 ,... e32.... Fax #: ( i ' g - 'JD 7 2 Print name:. a Phone: (5/2�)��2 —.. Address:` ,/ i AtE. City/Sta C.FU /au/rr t CITY OF ,T 'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ECHANICALPERMIT -REVIEWAND REQUESTED: (TO BE FILLED " OUT'BYAPPLICANT) Description of work to be done (please be specific): i._ i 1 ,y► :LA/ sl4 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 3 - a0 - oa Date application expires: Application taken by: (initials) 1I/2/99 meth permit. doc ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. .4. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat Toss calculations or Form H -6. Equipment specifications. Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in,safe condition. 11/2/99 miscpmi.doc Change -out or replacement of existing mechanical equipment 1 Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. • • INSPECTION RECORD Retain a copy with permit :: INSPECTION .NO. .. ITY OF T,UKWILA BUILDING DIVISION 300Soutlicenter Blvd #100 Tukwila, WA 98188 Approved per applicable codes. • Project .. igeoptgs Typefrjsp22: 1 Date Called: 4-2 — 1/ Date Wanted: 7 1 407 '79 Requester:— Phone No: 24 - P72 2 ,'I e' ISI Corrections required prior to approval. COMMENTS: ..•1Y • • ..• $17.ODREINSPECTI FEE REQUIRED. Prior to inspection, fee must be Paid'at t300:SciuthCenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: YlifitanageteMBIZEMMENNESERMSEEM r Parcel No.: 7888900150 Address: 18251 CASCADE AV S TUKW Suite No: Tenant: ENCORE BROKERS INC 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 12: An approved automatic fire - extinguishing system is required for this project. 13: All new automatic fire - extinguishing systems and all modifications to exsting automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 14: Local U.L. central station supervision is required. (City Ordinance #1900) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 16: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) 17: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 18: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 19: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575- 4407. doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Permit Number: MO2 -052 Status: ISSUED Applied Date: 03/20/2002 Issue Date: 04/04/2002 MO2 -052 Printed: 04 -04 -2002 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions tA )4t MO2 -052 Date: � 'z] p Printed: 04 -04 -2002 Parcel No.: 7888900150 Permit Number: MO2-052 Address: 18251 CASCADE AV S TUKW Status: APPROVED Suite No: Applied Date: 03/20/2002 Applicant: ENCORE BROKERS INC Issue Date: Receipt No.: R020000449 Payment Amount: 56.00 Initials: SKS Payment Date: 04/04/2002 09:13 AM User ID: 1165 Balance: $0.00 Payee: W.A. BOTTING COMPANY TRANSACTION LIST: dew, Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 Amount Type RECEIPT Method Description Payment Check 115653 56.00 ACCOUNT ITEM LIST: Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES Description Account Code 000/322.100 44.80 000/345.830 11.20 Total: 56.00 04/04 7ib TOTAL 56.1)0 Printed: 04-04-2002 P o ,, ;� {} MITI, LA Type of Ins I Add Date called Special instructions: l Date want . hi I Requester. , 4 1/ ' (J1 P eocp) 36 P-75a7 . ;?.��':.,�:; ra:x.;t�4:... _ «r.: � ±i� «;a`:' i:, ux.'.: t:.. �,'.:;: ix; •f'r:v,v..:;..�i. >...'�t�;'.'r i.. INSPECTION NO. CITY OF:TUKWILA BUILDING DIVISION 6300.SouthcenterBlvd, #100, Tukwila, WA 98188 Approved per applicable codes. :'C':Y'iTE�i?`k'.w.�5`'.:C:�, •G .,..= + t': :::iii: INSPECTION RECORD Retain a copy with permit 1Ioa -osa PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: Q: 73 ite --; RI/ G' )) t2 a 1 ~.�t� / (/)7 Z.i ►- a h �, • Li 5 Inspector: E INSPECTIO FEE RE REQUIRED. P Date $47.00 R Q Prior inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • Project: tAl GatC. Type= lectir:: • ," " ' - Addressi _ 1 1 f f l'8g5 I 6 ameadtAILS Date called:, -'..-. . . Special instructions: Date wanted: 7 i Requester Phone: - " 4?06-.73 • irA T_ 1. 1 :3 fl- INSPECTION RECORo Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 . INSPECTION NO. MO6-0‘A PERMIT NO (206)431-3670 pproved per applicable codes. [II Corrections required prior to approval. COMMENTS: o,. L44 Key 0 REINSPECTION FEE EQUIRED. Pr or to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Cal to schedule reinspection. Receipt No: eat Date; • reg 0 co 0 co Ill ijE u j 0 ILJ g < co 3 I— 0 Z F— LU uj 0 0 — 0 i— tu u j g U. /6 0 CITY Of TUKWILA APPROVED MAR 2 9 2002 AJ AS 140IED j •,', e"";': 4 . - ..... , „ L) c,,..... N c;..,..;,A..r.,,,.., ....._., ..., ... 3 rri. jem 0. ipc...4,....2,._...., ...... ,....„...4: -C). 4 ....,,F , ....,...., . , -4....., vv. - .1 rls.....e :,-...... c:,... •t;: •-' 1: „,. .- c; )-3'•-• 1 ,-, • - . •-- , ...,, •,. . - Catalog 10-115H Belt Drive Upblast Centrifugal Exhausters Series NIBT 240A MAR 2 0 ZOOZ CENTER M01-00-- MODEL NBRTD DIMENSIONS (INCHES) WHEEL DIA. A B C D E F H J K 140A 28 21 2 20 21 31 23 31/2 14 180A 32 241/4 151/4 3 24 25 35 271/2 3'/2 18 240A 41 271 191/4 3 30 311/2 44 33' 31 24 300A 50 30'/4 243/4 3 36 381/2 53 411 51/4 30 360A 60 35'/4 291/4 3 42 46 63 471/ 51/ 371/4 480A 70 41V4 34'/2 3 50 551/2 73 551/4 51/4 461/2 Commercial Kitchen Ventilator For Grease Laden Air 100% top discharge belt- driven centrifugal power roof ex- hausters designed especially for restaurant and cafeteria range hoods, where top discharge of air is now required. All NBRTD belt driven exhausters are U.L. listed and have a capacity range of 654 to 21,792 CFM. NBRTD exhausters are built to handle high exhaust requirements and their low contour and bold, simple lines complement any building structure. Features • Motor compartment is forced cooled when operating, seal- ing the motor from exhaust air, while providing positive cooling and maximum motor life. • Rugged overlapping skirt spinnings are closed at base to form built -In grease trough with drain. Assures 100 up- ward discharge of exhaust air. Upper edge of skirt spin- ning is beaded for strength. • Designed to prevent entry of snow or rain into building when fan is not operating. Eliminates the requirement for damper on discharge side of the fan. • Specially designed cover directs the flow of air upward, and away from the roof. Virtually eliminates contaminants from accumulating under the fan or on the roof. • Rugged, corrosion resistant, spun aluminum housing; heavy -duty steel substructure; galvanized steel curb cap; stainless steel and cadmium- plated fastenings. • Premium tubular frame design to provide maximum strength with minimum weight. • Prelubricated ball bearing drive and motor mounted in compartment isolated from exhaust airstream. • Heavy -duty cast iron adjustable pulleys to permit speed variation. • Non - overloading, all aluminum wheel and hub dynamically and statically balanced assures long life and quiet operation. • Single screw adjustment of belt tension maintains cons- tant air delivery. • Heat shield — nominal 1" thick metal foil insulation on motor compartment base plate. Page 10 / Catalog 10 -115 JennFan, SnyderGeneral Corporation, certifies that the NBTD /NBRTD models shown herein are licensed to bear the AMCA Seal. The rat- ings shown are based on tests and procedures performed in accordance with AMCA Publica- tion 211 and AMCA Publication 311 and comply with the AMCA Certified Ratings Program. Dimensional Data .-.2‘40/1 • Removable external covered grease trough (optional). • External mounted weatherproof junction box. • Class B insulated motor. • Designed for maximum operating temperature of 300° F. NOTES: 1. For accessories see page 2. 2. For complete roof curb selections available see page 11. 3, 140A, 180A and 240A NBRTD models may be used for wall mount. Models must be ordered for wall mount. 4. Products with 5 HP motors with larger than 184T frame, motors will be shipped separately. 5. NBRTD models are available as U.L. 762 listed for units with 1 /4 to 5 HP motors. Units requiring a 1 / 6 HP motor will be provided with a 1 /4 HP motor. NOTE: NFPA-96 requires at least 40 inches of clearance from the discharge to the roof surface when unit is used for kitchen exhaust. The NBRTD models from 1/4 HP through 5 HP are available as listed by Underwriters Laboratories (Subject No. 762) Investigation for Power Ventilators for Restaurant Exhaust Appliances. NOTE: When used as a restaurant exhaust appliance. the Ian must be installed in accordance with NFPA•96. Also consult local codes. These fans are listed by the Canadian Standards Association Testing Laboratories as approved. D J r4 2 0 co 0 co W uJ O LLQ W g. O Z W 0 � O — tD F- Ili 'L i w Z 0 O F- Z Model 240A Speed Range Horsepower 0" SP %" SP Ye SP %" SP Vi" SP 4'4" SP 1" SP 1Vi" SP 2" SP 219" SP RPM CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM _ ion's' BHP Sonesl BHP Son's' BHP Sanest BHP Sonesl BHP Sonesl BHP Sonesl BHP Son's► BHP Son's' BHP Son's] BHP 2036 1576 345 4.1 1 .047 3.61.060 1 1 1 1 1 1 1 2184 1769 1161 370 4.7 1 .057 4.4 1 .072 3.2 1 .073 1 1. 1 1 1 1 2420 2054 1506 410 5.7 1.078 5.6 1 .097 4.4 1 .101 1 1 1 1 1 1 470 2774 2447 2080 1701 7.2 1.118 7.2] .141 6.3 1 .154 5.41 .152 1 1 1 1 1 510 3010 2698 2402 1926 1792 8.3 1.150 8.31 .178 7.5 1 .191 6.6 .196 6.0 1 .047 1 1 1 1 550 3246 2946 2697 2318 t 1952 9.4 1.189 9.6 1 .219 8.8 1 .236 7.91 .248 7.2 1 .243 1 1 1 1 ► 575 3394 3100 2872 2542 2080 10.2 1 .216 10.4 ► .248 9.7 1 .267 8.7 1 .281 8.0 1 .279 1 1 1 1 590 3482 3193 2975 2667 2236 10.6 1 .233 10.9 1 .267 10.3 1 .287 9.3 1 .301 8.5 1 .304 1 1 1 1 635 3748 3469 3271 3020 2675 1361 _ 12.1 1 .290 12.4 ► .328 11.9 ► .352 11.0 1 .367 10.0 ► .382 9.1 ► .315 ► ► ► .....-1 670 3955 3684 3494 3277 2986 2402 13.2 1 .341 13.6 1 .382 13.3 1 .409 12.4 1 .426 11.4 1 .444 10.2 1 .439 1 `! l J�J 725 4279 4021 3838 3660 3425 2762 1792 J 15.1 1 .432 15.6 1 .478 15.5 1 .510 14.7 1 .533 13. .548 12.3 .488 ► ► 7 4545 4296 4118 3956 3758 3205 2778 16.7 1 .518 17.3 1 .567 17.2 1 .603 16.7 1 .630 1 .8„1�662=J3 -te 13.2 1 .667 1 1 4928 4693 4519 4370 4211 3777 3168 18.7 1 .660 19.2 1 .714 19.1 1 .757 18.6 1 .789 17.9 1 .814 16.3 1 .854 15.3 1 .862 1 1 ► 850 5017 4785 4611 4464 4312 3899 3320 19.1 1 .700 19.6 1 .752 19.5 1 .795 19.0 1 .829 18.3 1 .856 16.7 1 .896 15.8 1 .913 1 1 915 5401 5180 5010 4869 4734 4398 3939 3120 21.0 1 .869 21.01 .929 21.0 1 .979 21.0 1.01 20.0 1 1.05 18.7 1.09 17 8 1 1.14 16.0 1 1.11 1 ► 950 5607 5393 5225 5086 4957 4652 4244 3390 22.0 1.972 22.01 1.04 22.0 11.09 22.01 1.13 21.0 1 1.17 19.8 11.22 18.911.26 17.0 11.25 1 990 5843 5636 • 5470 5333 5208 4934 4570 3540 23.0 11.10 23.01 1.17 23.0 11.22 23.01 1.27 22.0 1 1.31 21.0 11.37 20.01 1.41 18.5 11.42 1 1040 6138 5939 5777 5641 5520 5275 4955 4056 2752 25.0 11.28 25.01 1.35 25.0 11.41 24.0 1.46 24.0 1 1.50 23.0 1 1.57 22.01 1.61 21.01 1.67 19.0 1 1.54 1070 6315 6120 5960 5825 5706 5472 5177 4351 3842 26.0 1 1.39 26.0 1 1.46 25.0 1 1.53 25.0 1 1.58 25.0 1 1.62 24.0 1 1.70 23.0 1 1.74 21.0 ► 1.83 20.0 1 1.79 1110 6552 6362 6205 6071 5953 5730 5465 4728 3863 27.0 1 1.55 27.0 1 1.63 27.0 1 1.69 26.0 1 1.75 26.0 1 1.80 25.0 1 1.88 24.0 1 1.93 23.0 1 2.04 21.0 1 1.99 ► 1155 6817 6634 6479 6347 6231 6017 5779 5126 4212 1676 28.0 1 1.75 28.0 {1.83 28.0 1 1.90 27.0 1 1.96 27.0 1 2.01 26.0 1 2.10 25.0 1 2.16 24.0 1 2.27 23.0 1 2.27 20.0 1 1.60 Belt Drive Top Discharge C N eT Series 240A tt al Exhauster Page 6 / Catalog 10 -115 JennFan, SnyderGeneral Corporation. certifies that the NBTD /NBRTD models shown herein are licensed to bear the AMCA Seal. The rat- ings shown are based on tests and procedures performed in accordance with AMCA Publica- tion 211 and AMCA Publication 311 and comply with the AMCA Certified Ratings Program, NOTES: 1. BHP does not include belt drive losses. 2. Performance shown is for unit without inlet ducts. 3. The sound ratings shown are loudness values in fan sones at 5 It. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A. tree inlet tan sone levels n 9 J z t � W UO fn 0 W J IE N � WO 2 P._ a W W V 0 H W W U. O W U= O Z Efficient and Effective Cooling. When you need to cool a home, condo- minium, manufactured housing or apartment complex, these reliable standard coolers are the low -cost alternative to expensive refrigerated air conditioning systems. Unlike air condition- ing systems that recirculate dry, stale air over and over, our evaporative coolers circulate clean, fresh air using as little as 1/4 of the electricity required for air conditioning. That's up to 75% savings in electric costs. We offer you a choice in our ducted line of coolers. With 3 side - discharge and 3 down - discharge models offering different cooling and horsepower capacities, you're assured of getting the exact cooling requirements for your job. And, with our aids and accessories, coolers can be mounted on roofs, set on pads, or hang on an outside wall. Remember, you can also add one of our coolers to an existing air conditioning system. Our ducted coolers have a 5 -year limited warranty on cabinet leakage due to rust -out which is backed by the industry leader with over 50 years of evaporative cooler manufacturing experience. Our ducted coolers are C.O.L.A. (City of Los Angeles) Approved. Standard features Cabinet rrosion resistant, heavy gauge galvanized steel. POLY- BONDS coated, welded, maintenance -fret cabinet with reinforced corner posts for added strength. O Protective Finish r POLYBOND ® exclusive coating, is an attractive, appliance type finish that protects the exterior and all parts contacting water to resist corrosion. This finish Is so durable it is backed by a five-year warranty against leakage due to rust -out. R Bottom Pan ORIGLNAL sturdy deep drawn steel bottom pan with Plastisol seal makes for a leak -proof design. °Motor L.L recognized motor designed and tested specifically for use in evaporative coolers. Special features include mois- ture resistant rotoustator with special winding and pro- tected switch mechanism. High torque and isolated vthra• ion characteristics nuke it quiet and efficient ©Water Trough Specially designed. one -piece POLYBON'D tis protected water trough enhances even water distribution and is clog -free. ()Pad Frame Heavy duty, embossed pad frame for long life Ircle® ED330/430/630 ES330/430/630 I l t st■olos MADE IN U.S.A. Pump ghest quality pump in the industry. U.L recognized flame-retardant plastic, designed to operate at doe widest range of water levels in the industry. Built -in blecd•otf adapter and (Inc mesh filter screen prevents clogging. The pump shaft is encased in plastic to eliminate the possibility of corrosion. ()Water Distribution Specially designed system for even water distribution is retained with corrosion resistant hot-dipped galvanized steel retainer clips ()Blower Wheel Balanced blower wheel of heavy gauge galvanized steel. for quiet operation and maximum au flow Sturdy shaft fits firmly into keyed pulley Blower Support Bar Durable. heavy gauge plower support bar Easy Access Pad Frames orrosion resistant, spnng•steel snap latch system Float Valve Adjustable float valve wish Celcon seat and Buena plunger designed for most efficient operauun putted Aka 1er ; � .i iv ►*1 Models _ _ _ ED330/430/630 -� ES330/430/630 T Bleed•Of'/ Klt ensure consistent performance. every unit has a bleed• off kit included. Drive System Dependable operating drive system tested for long life ®JunctIon Box Factory installed, plug-in junction box conveniently located for easy access. All components arc U.L recognized and the junction box is approved by the City of lus Angeles. - .M"P.: }ea:.H. .n•.x:^+?'ttY.•+:Y.�wri ;n �Ilrik:.MLi;.Mil , Model Number Certified Ind. Rating 0 stattic pressure i (water gaugejute) .1 .20 .4 .5 Ind. Rating HP Electrical Specifications Speed Phase Volts Amps Watts Part na Pump GPM Head tit.) Bleed- GPM ES/ED330 3000 1900 1865 1825 1745 1620 1460 3000 13 1 or 2 1 115 8.4 617 EP200A 2 45 5 2 4 ES /ED430 4000 3100 3020 2850 2625 2290 1900 4000 ' 1 or 2 1 115 8 4 617 EP200A 2.45 5 3 6 ES /ED430 4500 3600 3530 3350 3120 2860 2565 4500 '7 1 or2 1 115 9.6 730 EP200A 2.45 5 4 2 3'2 — ' 5 1'4 3 3028 16 16 59 10 2202 135 308 E0430 230 5.2 730 EP400A 2 45 5 4 2 ES /K630 , 5500 4300 4000 3730 •• 3370 3280 5500 ' 2 1 or 2 1 115 9.6 730 EP200A 2.45 5 4 7 12'/4 6 18'h 6 3'h — 5'n 1:4 3/36/31 19'18 : /4 68 13 230 5.2 730 EP400A 2 45 5 4 7 ES /E0630 6500 4900 4610 4350 4080 3920 3880 6500 3 4 1or2 1 115 11 8 930 EP200A 2 45 5 5 5 230 6.0 930 EP400A 2.45 5 5 5 Number H Cabinet W 0 Duct Opening Location A B C E Drain Location F G Bottom Pan Depth K thRI r Water• Service Knock• out Elaclrlcal • Service Out Knock-Out N oM d Blower S d1 h a l litt Length g Blower Pulley Pitch Dia. Effective Pad Aria (aq, ,n.) WI hts' 9 Ship Operate ping ing ES330 28'4 28 28 13 13 10 7' a 14 4' 4 3'2 — 5'2 11/2 3.23 23 12 12 3 '4 45 6 1273 80 180 E0330 281/4 28 28 13 13 4 7 14 41/4 3 33/4 5 1'h 4 12 12 3 /4 44 63/4 1697 90 190 ES430 35 34 34 17 17 11 8 17 54 3'2 — ' 5 1'4 3 3028 16 16 59 10 2202 135 308 E0430 35'4 34 34 17 17 4 8's 17 544 3" 33', 51/2 1'4 4.30.28 16 16 58 10 2936 145 318 ES630 42'4 37 37 19 19 12'/4 6 18'h 6 3'h — 5'n 1:4 3/36/31 19'18 : /4 68 13 3072 180 400 00630 42'4 37 37 19 19 4 Bsb l8'5 6 3 3 5'a 1'4 4/36131 1918 66 13 4096 190 410 ED430 E0630 ES330 ES430 ES630 DIMENSIONS: SPECIFICATIONS: UPC BAR CODES: ED330 - 047906433303 - 047906434300 - 047906436304 - 047906423304 - 047906424301 - 047906426305 DOWNDRAFT A garoCIrdee Adolber414/nc, • 500 S. 15th Street • Phoenix. Arizona 85034 We reserve the right to change specifications without prior notice or liability. SIDE VIEW y .4 c J 1 t SIDEORAFT , In pounds. Sideldown discharge weights shown. Shipping weight is cabinet and carton. Accessories and motor boxed separately. 2 Not recommended above .5. 'Blower motor (high speed) and punp. ' ' Hob for 1/2' electrical fitting. Vrain Is 3/4' male hose thread. ' Water Knock out clearance for running 114• tubing. Cooler Versatility Our ducted, window model and portable coolers are suitable for installation on may types of living accommodations, leisure and workspace areas. Select the model you prefer based on size space to be cooled and the mounting technique needed. Installation Aids and Accessories We provide a complete line of quality installation aids and accessories. Water connector kits; cooler switches; thermostats; grills; mounting brackets and skirt kits (with POLYBOND°) are a few of the accessories available. Contact your contractor, home supply store or us directly. Our evaporative coolers and components are designed and tested in accordance with one or more of the following standards or agencies: Mr Delivery — Data published derived from tests conducted in accordance with A.M.C.A. (Air Movement and Control Assoc.) Standard 210. Aspen Pads — Built to Federal Specification PP-E-911 for Type 1, Class A, Grade 4. Sealant • Water Immersion — per ASTM D870 • Flexibility — per ASTM D756 • Corrosion Resistance — per ASTM 8117 • Cycle Freeze/Thaw — per ASTM C117. POLYBONDS • Corrosion Resistance — per ASTM B117 • Pencil Hardness — per ASTM D3363 • Adhesion — per ASTM D3359 • impact Resistance — per ASTM D2794 • Flexibility — per ASTM D522 • Specular Gloss — per ASTM D523 • Surface Burning Characteristics of Building Materials (best rating) Per U/L 723 and ASTM 0.84. Motor and Pumps — Recognized under the U/L component recognition program for the application — construction, thermal overload, running overload, and locked rotor protection. Polymeric Materials — Tested in accordance with U/L 94 and 756C. L900797A Rev 1091 •v fj State of Washington County of Snohomish Dated: DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL .REGIST. # .EXP. DATE CC01 WABOTC *099JA 04/01/200 EFFECTIVE.. DATE . 04/01/1991 W A HOTTING COMPANY PO BOX 1200 STE 200 WOODINVILLE WA 98072 • y . r - r.. r - •� - Y �i . r+ .�� " �:u ter 47.: • ; • te r u...rs ���� •���. r:.. • . • I certify that this is a true and correct copy of a document in:the possession of W.A. Botting Co. as of this. date. Notary 1ic in and for the State of Washington My appointment expires: ..�.:,.b.a:.. City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Lt W I U w N LL W0 g a to 3 = W W U 0— Based on the above, you are hereby advised to: 0 1— W U w •Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next scheduled inspection LL ~O This inspection is intended to determine if substantial work has been accomplished since issuance of the V LP- permit or last inspection; or if the project should be considered abandoned. H The Building Code does allow the Building Official to approve a one -time extension up to 180 days. Z Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to October 15, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. September 9, 2002 Mr. Doug Walter 19405 144 Av NE Woodinville, WA 98072 RE: Permit Application No. MO2 -052 Location: Encore 18251 Cascade Av S Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Thank you for your cooperation in this matter. Sincerely, KCl✓t Gib Lu C � ,d C Cl/u Kathryn A. Stetson Permit Technician Xc: Permit File No.MO2 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 - 3665 �.�� t TYPE I EXHAUST SYSTEM SPECIFICATIONS TYPE I WALL CANOPY 10 -0" x 3' -6" Capture 10 -0' x 3' -9" Overall Constructed of fully welded 18 gauge stainless steel - liquid tight to include U.L. Classified - baffle type grease filters. Make -up air ductwork constructed of' fully sealed 24 gauge galvanized steel. 1997 U,M,C, REQUIREMENT @ 100 CFM PER SQ FT x 35.00' = 3500.00 NORTH EXHAUST FAN 3/8' ALTHREAD HOOD HANGER Jenn Fan Model #NBRTD -240A - 1HP - 220V - 1PH 3500 CFM @ .625' ESP 785 RPM - WT. 190 LBS. Includes grease catch receptacle Arctic Circle Model #ES -630 - 1 /2HP - 115V - 1PH 3500 CFM @ .300 ESP 115V - 1PH 23' 19' 6' -6' WEATHER SHIELD EXHAUST SYSTEM FAN MAKE -UP AIR SYSTEM 19/18 EXHAUST DUCTWORK Exhaust Duct to be 18' x 18' @ 3500 CFM = 1556 FPM Velocity Exhaust ductwork constructed of fully welded 16 gauge galvanized steel. Make -up air ductwork, insulated per UMC 20' x 20' @ 3500 CFM = 1259 FPM Velocity ONE HOUR FIRE RATED DUCT ENCLOSURE EXHAUST SYSTEM SECTION Scale 1/2' = 1' 0' EXHAUST SYSTEM ELEVATION TYPE I EXHAUST SYSTEM NOTES 1. The exhaust and Make -up air systems are to meet requirements of' the Uniform Mechanical Code and NFPA - 96. 2. Exhaust hood and ductwork must be located a minimum of 18' from any combustible material. Exhaust must be a minimum of 10' -0' from any air intake, adjacent building, or adjoining property lines. 3. Exhaust and make -up air systems must be electrically interconnected to be operated simultaneously by a single on /off switch. 4. Any Type I exhaust system shall have a fire suppression system. APPROXIMATE SYSTEM EQUIPMENT WEIGHTS EXHAUST HOOD W/ COMPONENTS EXHAUST SYSTEM DUCTWORK EXHAUST FAN MAKE -UP AIR FAN MAKE -UP SYSTEM DUCTWORK TOTAL 1045 LBS. NOTE: THE EXHAUST AND MAKE -UP AIR FANS AND THE EXHAUST HOOD ARE EXISTING EQUIPMENT THAT ARE RELOCATED FROM ENCORE BROKERS, INC. PREVIOUS BUSINESS LOCATION 0 ..%•. - aut EXHAUST FAN / WEATHER SHIELD ONE HOUR FIRE RATED DUCT ENCLOSURE 3/8' ALTHREAD HOOD HANGERS 18/18 24' MINIMUM z r-6'MM. 6 MIN. STAINLESS STEEL WALL FLASHING / ON METAL STUD WALL CONSTRUCTION IrAIVAIrAVAV COOKLINE EQUIPMENT (NO BROILERS) Dr - 0' MINIMUM FROM ANY AIR INTAKE 20/20 380 LBS. 140 LBS. 190 LBS. 180 LBS. 155 LBS. 23' I.D. MAKE -UP AIR UNIT 00 og BEAM 32' ONE HOUR FIRE RATED DUCT ENCLOSURE X U.L. DESIGN #U -405 ROOF PENETRATION FOR MAKE -UP AIR DUCTWORK I.D. Dimensions of Curbed Roof Penetration 20' x 20' Insulated Make -up Air Ductwork Scale 1/2' = 1' 0' NON -FIRE RATED DUCT BUILDING PENETRATION EXHAUST HOOD EQUIPMENT PLAN VIEW Scale 1/4' = 1' 0' SITE PLAN VIEW 5/8' GWBX - Fire Taped 2 -1/2' Metal Stud Construction 5/8' GWBX - Fire Taped 3' Air Space (3' Min. - 12' Max.) 14' x 24' Welded Exhaust Ductwork ENCLOSURE RUNS FROM FINISHED CEILING TO 18' MINIMUM ABOVE FINISHED ROOF SURFACE No Scale No Scale EXHAUST FAN 10'0' MINIMUM it p LI e �1 GAS PlolNG OF 'FUKS` t $ITMp`NG 0IViSIOM RIVERSIDE DR ENCORE BROKERS, INC 18251 -B Cascade Ave. S Tukwila, WA 98188 CASCADE AVE S Not to Scale MAKE -UP AIR FAN 0Z° 0'17 I understand that subject o : r . I c pans does ? h z t c any ! adopted co c: r pt c con- tractors copy of roe,.,. ,_.a s _ < .,.d eged- 1 By 4 t Date V- - L�2_ Permit No. MO2' 052 CITY OF TUNwi(11'.. AMMO MAR 29 2002 Kt3 � As psolED ) RI.P.JYNG 3 FIRED OCT 1t 2002 MAR Z 0 `LOU CLIMATE ENGINEERS 19450.- 144TH AV=_, NE wmaN,, =,. a 90202 PHONE: 425-L82-9500 A DIVISION OF W.A. DOTTING COMPANY PROJECT ENCORE BROKERS INC. DATE 3/19/02 JOB NUMBER 6668 -01 CONTACT DOUG WALTER 50 YEARS OF SOLUTIONS IN AIR Heating, Ventilating and Air Conditioning Systems - Specialty Sheet Metal Design -- Fabrication: - Installation CONTRACTOR'S LIC. NO. WABOTC•099JA SHEET 1 of 1