Loading...
HomeMy WebLinkAboutPermit M02-089 - SWEET BASIL RESTAURANTM02 -089 Sweet Basil 16876 Southcenter Py cc LLI2 0 No w 11J =' • LL W O' 2 92 a 3. p, U O N, OH W W. V: • O , Z uj O Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049129 Permit Number: MO2 -089 Address: 16876 SOUTHCENTER PY TUKW Issue Date: 05/22/2002 Suite No: Permit Expires On: 11/18/2002 Tenant: Name: SWEET BASIL RESTAURANT Address: 16876 SOUTHCENTER PY, TUKWILA, WA Owner: Name: CAPITAL & COUNTIES USA Address: 101 CALIFORNIA ST #2525, SAN FRANCISCO CA Contact Person: Name: THOMAS LI Address: 10609 ROWLAND AVENUE SW, LAKEWOOD, WA Contractor: Name: S A CONSTRUCTION Phone: 253 973 -8500 Address: 27526 26TH AVENUE SOUTH, FEDERAL WAY, WA Contractor License No: SCONS * *022LS Expiration Date: 06/15/2002 DESCRIPTION OF WORK: INSTALLATION OF A COMMERCIAL KITCHEN HOOD, INCLUDING AN EXHAUST FAN, AIR MAKE -UP FAN AND DUCT SYSTEM Value of Construction: Type of Fire Protection: Permit Center Authorized Signature: Signature: Print Name: doc: Mech $ 7,500.00 N/A .gNer(A ( 51 JNT l MECHANICAL PERMIT Phone: 415 421 -5100 Phone: 253 973 -8500 Fees Collected: Uniform Mechnical Code Edition: lA i U2 Date: 5 ' a ”"Q Z MO2 -089 $68.88 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construct)on or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: S12 2/U 2_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 05 -22 -2002 DEPARTMENTS: ACTIVITY NUMBER: MO2 -089 PROJECT NAME: SWEET BASIL RESTAURANT SITE ADDRESS: 16876 SOUTHCENTER PARKWAY XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 04 -18 -02 Revision # After Permit Is Issued Buildin s Public orks 1✓ C _ PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Struf ctural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Planning Division Permit Coordinator DUE DATE: 4 -23-02 x Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route [Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 5 -21 -02 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Oocumentskouting stip.doc 2-28-02 kLRMIT COORD COPY DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: MO2 -089 DATE: 04 -18 -02 PROJECT NAME: SWEET BASIL RESTAURANT SITE ADDRESS: 16876 SOUTHCENTER PARKWAY XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Documents/routing slip.doc 2.28.02 APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS RO TING: Please Route ' Structural Review Required ❑ No further Review Required REVIEWER'S NITIALS::.,f Approved Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 4-23-02 Complete pgf Incomplete ❑ Not Applicable ❑ Comments: i,,4 ) comp(O . dfitOlb, Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: 4 DUE DATE: 5-21-02 ❑ Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • PERMIT NO.: MO 2 089 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 2 Pre- construction ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 610 Chimney Installation/All Types ❑ 700 Framing ❑ 1080 Woodstove ❑ / 1090 Smoke Detector Shut Off 1100 Rough -in Mechanical ❑ 1101 Mechanical Equipment/Controls ❑ 1102 Mechanical Pip /Duct Insul ❑ 1105 Underground Mech Rough -in ❑ _ 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final 4015 Special -Smoke Control System CONDITIONS 10001 No changes to plans unless approved by Bldg Div 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I 10005 All permits, insp records & approved plans available 10014 Readily accessible access to roof mounted equipment 9,) 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: S P\LSTA utzp, !J T FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'1 Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Plan Reviewer, Permit Tech: Date: ✓ l Sil CZ Date: 6- jV v Dv Ug N W. WD 2 QQ u-Q N 3 O 111 � • 0 • c 0 ; 1— W W. F U N O Z PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -089 PROJECT NAME: SWEET BASIL RESTAURANT SITE ADDRESS: 16876 SOUTHCENTER PARKWAY XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 04 -18 -02 Revision # After Permit Is Issued DEPARTMENTS: Building Division ❑ Public Works ❑ Complete ❑ APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Planning Division Permit Coordinator DUE DATE: 4 -23-02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE. LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 5 -21-02 DATE: % O? 3 - Oa ❑ Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: A_ -� /h Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Project Name/Tenant:$ / L 1 Q5r / R-es�a ol. rer /71- ( G / / �1 T Value o7�� al Equipment: Site Address : G 7 //� � � /�� City Stat �}/ -i Tax Pa c ,( Property O nen �r etor rJDyE Signature:, Phone: ( ) / - ?�S " — f9' d - /,200 Syyeet Addres s: 44 _ #P Cit State/Zip: Fax #: ( ) Contractor 4.. / Print name: 76 L ) Phone: ( ) Phone: ( Street Address: 4 Ain_ C Zip: Fax ) grr i, 74 T Contact Person: �/�as G l t Phone: ( ) 3 -r73 - -RS F�jdd / Obf� �c&.D .4hI/f ,�p W zejezua� ,�jtyS Fax ( q41 / ' 4BUlIDINGfO �E'R.:ORAU.THOR/ZED1'CENV: 1 " .. Signature:, Date: /g / e>2___ Print name: 76 L ) Phone: ( _ Fax #: ! �/r Add / 7 �Dh/Dr✓srGI 41- PI t City /State/Zip: 4t JM WI q 5 CITY OF T(KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: ',1 11I IN ONIY Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. f, Y1 EdiiA AIJP i:RMITrREVIEW AND AP.PROWAL REQUESTEDe (TOrBE "F /LL' D;OUTBVAPPL /CANT)`, `, Description of work to be done (please be specific): /rJO � /�� i ark A c leY e map ‘eiz, P. a cts`f kl • A.- emote y /t-Yt, K 1.t e , 11/2/99 meth pernadoc Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: y -/er do Date application expires: Application taken by: (initials) z w re 0 0 U) U) u_ WO 2 LL < to d I- z = I— O W H Ljj D 0 0 O 0 F- W H IL O .z . W U= H� O z ✓ Submittal Rvquirentwtls Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requirements New Single Family Residence Heat Toss calculations or Form H -6. Equipment specifications. 11/2/99 mtscpmt.doc Change -out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. City fr Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049129 Permit Number: MO2-089 Address: 16876 SOUTHCENTER PY TUKW Status: ISSUED Suite No: Applied Date: 04/18/2002 Tenant: SWEET BASIL RESTAURANT Issue Date: 05/22/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296 - 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 12: Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking application shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is automatically shut off to all equipment under the hood, when the system is actuated. (UFC 1006) 13: A wet chemical portable fire extinguisher having a minimum rating of 2A:1B:C:K shall be installed within 30 feet of commercial food heat - processing equipment, as measured along an obstructed path of travel. (UFC 1006.2.7). 14: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 15: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1900. 16: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) 17: Local U.L. central station supervision is required. (City Ordinance #1900) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 19: Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1900) 20: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire doc: Conditions MO2 -089 Printed: 05 -22 -2002 i City o fr l ik.1 a Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Alarm" or "Fire Alarm Control ". (City Ordinance #1900) 21: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 22: In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) 23: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. (City Ordinance #1900). 24: ** *ELECTRICAL * ** UFC Article 85 - NPFA 70 - NEC 25: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) 26: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 27: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 28: Doors into electrical control panel rooms shall be makred with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. (UFC 8509.3) 29: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 30: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575- 4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Te hC)LCL �JY+ 1 doc: Conditions MO2 -089 Date: -- V2Z Uz— Printed: 05 -22 -2002 Payee: SWEET BASIL TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt Af City of T ukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Current Pmts Amount Payment Cash MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Type Method Description Parcel No.: 2623049129 Permit Number: MO2 -089 Address: 16876 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 04/18/2002 Applicant: SWEET BASIL RESTAURANT Issue Date: Receipt No.: R020000689 Payment Amount: 68.88 Initials: KAS Payment Date: 05/22/2002 02:52 PM User ID: 1684 Balance: $0.00 68.88 Description Account Code 000/322.100 55.10 000/345.830 13.78 Total: 68.88 Printed: 05 -22 -2002 sect: c,u - � a r�4 v Typ f inspyection: f- d uc tdrI7 Date 5.c. ri< I I called: Special structions: Date wanted p n. / � �� Re er: rin ki Pho : 0) tf IC. 3 I . 3 INSPECTION NO. •CITY OF,TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 98188 INSPECTION RECORu Retain a copy with permit ;')'9) • PI Da -O.g , ) ER IT NO. /�'�/ (206)431 -3670 Approved per applicable codes. fl Corrections required prior to approval. COMMENTS: $47.00 REINSPECTION EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call t� schedule reinspection. Receipt No: Date: • (206)431-3670 Type of Inspection: Date Wanted: Requ ter: : .:IN S PECTION REC Retain a copy with permit INSPECTION NO. • ITV OF TUKWILA BUILDING DIVISION 300Southcenter131vd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: rod used -coy V‘ood VIIAS ( ct -e-or • f.fAcit4z. or 0, votlick \ S4-civvrck n pp r OCil 1 I t -4-' ow f riCre IAC)nd 2-0A'Gt tit "">icstf %An -CtAr (..U0/4114, - -e \va.. ssue - v;:e eirs VO•PtA4 40 Int o A r))0si .." • Inspector: 4,14 4" IT 0 orrections required prior to approval. Date: o it _ 02 $47.00 REINSpECTION FEE REQUIRED. Prior to inspection, fee must be paid at300Southcenter Blvd., Suite 100. Call to schedule reinspection. r eceipt No.:" 'Date: Project:.. :: .. / ,U16 -• .. /L k T Type of Inspection: - / Ai ) c 0 &Ugh - Addres :: e .76 :S urqo,e P Date C d: a Y - 6 - o� Special Instructions:. )_ %/...':-... • } .eli.,``7.::< . , �Q . L Date W nted: 7 —q ....c= m p.m. Requester: PONN5 Phone No: ■ INSPECTION RECcD Retain a copy with permit INSPECTION NO: ITLOF TUKWILA BUILDING DIVISION 300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. O. PE T (206)431 -3670 COMMENTS: GlX c ii g:,v47-7 7� % 4. % ' / z .ie y 1 .. /r (l 1 / /4-7 e-47, Corrections required prior to approval. $47.00 REINSPECT • N FEE REQUIREfti. Prior to inspection, fee must be .paid at 1300 Southcenter Blvd., Suite 100. Call to schedule reinspection. R No. :. IDate: City of Tukwila Project Name !�'� e-4 aqs i 0 P3"iCt4.' " Address /(, «- � • P Retain current inspection schedule Needs shift inspection Y Approved without correction notice 1 y 47.77 :k Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Y Halon: Monitor: rr- - - Pre -Fire: Permits: fi r / ; 11 Authorized Signature FINALAPP.FRM Rev. 2/19/98 Steven M. Mullet, Mayor Permit No. A101• " Date Suite # T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206-575-4439 Public Health Seattle & King County HEALTHY PEOPLE. HEALTHY COMMUNITIES. Alonzo L. Plough, Ph.D., MPH, Director and Health Officer April 12, 2002 Thomas Li Al Construction 10609 Rowland Avenue SW Lakewood, WA 98499 RE: Sweet Basil 16876 Southcenter Pkwy Tukwila, WA 98188 Dear Mr. Li: We have approved the plans for your food service establishment. Your establishment has been assigned the following business identification number (SR#1034544). Please use this SR# in all future contact with us. Before you open for business, you must complete the enclosed application for a permit and return with the correct fee of ($318.00) for a (6301) permit. If you open before you obtain your permit, your permit fee will be double. Before you open you need to schedule a pre - operational inspection by the Health Department. Although your application for a food service establishment permit from Public Health Seattle and King County will be approved during this inspection, you may need to obtain additional permits or approvals from other agencies. It is the responsibility of the food service establishment operator /owner to obtain all necessary permits and approvals. Operating the establishment without these required permits or approvals may subject you to legal action by the appropriate agencies. If you open without health inspection, you may be closed. Once your plumbing permit has been finalized, contact me at (206) 205 -1903 to schedule the pre- operational inspection. Failed pre - operational inspections will require a $100.00 fee for a repeat inspection. Be sure all other business inspections are done (plumbing, building, etc.) before you call for your Health Department inspection. Sincerely, (9g Mike Milbach Plans Examiner MM:dg Enclosure v Alder Square Environmental Health Services 1404 Central Avenue South, Suite 101 • Kent, WA 98032 T (206) 296 -4708 F (206) 296 -0163 • www.metrokc.gov /health WA% RECEIVED CITY OF TUKWILA APR 1 8 2002 PERMIT CENTER o Moe - o89 City of Seattle ® King County Gregory J. Nickels, Mayor Ron Siren, Executive • Z re 2 0 0 rn � O w Q . 52 a w D O - O I- = w 1— F.: u_ li z = z COMMERCIAL KITCHEN HOOD WORK SHEET/ CHECK LIST Two copies of this worksheet/checklist must accompany plan sets submitted with commercial kitchen range hood permit applications. It explains and organizes information needed by the Department of Construction and Land Use to efficiently review plans and issue permits. DCLU will keep this document as part of the permanent project the and will use it to verify code compliance. The applicant is responsible for assuring the accuracy consis- tency of the information. (� T3A 5) L <z /. A. Project Address: I C9 d 7 4 d c-! 77, rr /Tr P tA/ Y l U /& )i L f � � /c & B. Established use and history of building Is it an existing restaurant, food processing area or food service area? n Yes FfNo If no, provide construction or change of use permit number C. Location of exterior ductwork and mechanical equipment 1. Is ductwork or mechanical equipment located outside of building other than roof top? ri Yes No 2. Applicant shall provide plan and elevation views showing ductwork, duct enclosure, hood, cooking surface air supply, exhaust system, and equipment support system including structural framing detail (Examples 1, 2, and 3). D. Type of Hood 1. For grease and smoke removal: (Example: deep fryer, charbroilers, grill and roasting ovens) 2. For steam, vapor, heat or odor removal: (Example: steamer, pastry and pizza oven). Hood shall have a permanent, visible label identifying E. Type of material and gage TYPEIHOOD Duct and Ple,wm Hood Flashing 3. Is hood for solid fuel cooking equipment? If yes, a separate exhaust system is required. Type of Material Gage Min. Req. Proposed Stainless Steel Galvanized Steel Stainless Seel Galvanized Steel Stainless Steel Galvanized Steel 18 Ga. Ga. 16 Ga. . Ga. LC Ga. .1 22 Ga. Ga. 22 Ga. ZZ Ga. 22 Ga. Ga. it as a Type II hood. RECEIVED CITY OF TUKWILA APR 1 8 2002 PERMIT CENTER August 1998 Type I 1 Quantity Type II Quantity Yes ZNo TYPE II HOOD Gage Min. Req. Proposed 24 Ga. Up to 12" dia. Ga. 22 Ga. Up to 30" dia. Ga. 24 Ga. Up to 12" dia. Ga. 22 Ga. Up to 30" dia. Ga. NOT REQUIRED 2.z Ga. Gu. 24 Ga. Ga. MOZO89 Sheet 1 F. Quantity of air exhausted through the hood CANOPY HOOD Hood shall extend beyond cooking surface on all open sides not less than Min. 6" Proposed !o in. Distance between lip of hood and edge of cooking surface shall not exceed Max. 4' Proposed?' ft. Cooking surface area = X Hood area (A) = X TYPE I (N = 4 Q= 150A = 150 X HOOD (N = 3 or less Q = 100A = 100 X TYPE II (N = 4 Q = 75A = 75 X HOOD (N = 3 or less Q = 50A = 50 X H. Type Air Velocity CFM /Duct Area (Ft of Hood (FPM) Z ft2 cfm = %' a cfm . cfm. cfm. G. Exhaust duct system 1. Applicant shall provide the specified air velocity in exhaust d ct. 2. Duct size in. x . 1 8 in.,.duct area = in. x 144 NON- CANOPY HOOD N = no. of hood sides exposed 0 = quantity of air A = area of hood in ft L = lineal feet of the front cooking equipment surface Q =300L Q = 300 X = cfm. Q = 150L Q = 150 X = cfm. in = ft Proposed Air Velocity I Req. 1500 to 2500 "� � � / . 7 4 3 FPM II Recom. 500 to 2500 / 2. Static pressure loss duct in. + grease filters /extractor Static pressure Exhaust outlet location 1. Exhaust outlet shall terminate above roof in. at Extend above roof Distance from same or adjacent building Distance above adjoining grade Distance from property line Distance from windows and doors Distance from mechanical air intake Distance of duct above adjoining grade at alley 2. If exhaust outlet terminates at exterior wall, provide cleaning equipment. See Director's rules 5 -96. FPM in. + other in. = Total in. of H 3. Fan and Motor shall be of sufficient capacity to provide the required air movement. Fan motor shall not be installed within ducts or under hood. 71 0(4 Fan make and model /.;2 4 s 941,7 HP • 1 14 d cfm. Min. required 24 in. 10 ft. 10 ft. 10 ft. 10 ft. 10 ft. 16 ft. Li Yes Proposed in. ft. ft. ft. ft. ft. ft. No Sheet 2 I. Makeup air 1. Applicant shall provide makeup air not less than 90% of the exhaust. 17i cfm. 2. Makeup air system shall be electrically interlocked with the exhaust system, such that the makeup air system will operate when the exhaust system is in operation. Provide note on plan sheet no. 3. Makeup air shall be provided by a fan or motorized damper of sufficient capacity. Windows and door openings shall not be used for the purpose of providing makeup air. 4. If more than 2500 cfm supplied to the space other than the hood, provide heater capable of heating makeup air supplied to the space to 65 degrees F . Heater model # Input BTU Output BTU Heater CFM AFUE FAN t'Ciz - i;t)t( Vb .'F' \. 4 MOT RIZED DAMPER Make and model H.P. Recommended air velocity,500 fpm Static pressure ' /',3 & Ai 2 v/ in. at cfm. Duct area req. = cfm /500 fpm /500 = ft Duct Dimension A fix /,ir' , area � j, 0(Q2 ft Duct. Dimension req. = • Air velocity = cfm /area 4-1i' / . Dk E Eff. Damper opening X = ft2 = ‘ '‘// fpm J. Slope of duct and cleanout access { l� A 1. Horizontal duct Tess than 75' long min slope 1/4 in /ft proposed in /ft more than 75' long • min slope 1 in /ft proposed in /ft 2. Tight- fitting cleanout doors shall be provided at every change in ductwork direction. K. Duct enclosure Total no. proposed 1. Ducts penetrating a ceiling, wall or floor shall be enclosed in a duct enclosure from the point of penetration to the outside air. A duct may only penetrate,exterior walls at locations where unprotected openings are permitted by Table 5A of the 1997 Seattle Building Code. • 2. For code compliance purposes, it is acceptable to assume that ducts penetrating concrete, brick or steel ceilings, walls or floors shall require a 2 -hour fire - resistive duct enclosure, and for others, it shall be 1 hour. Type of Const. Min. Fire- Resistive Proposed Const. of Enclosure IF.R., II ER II, III, IV, V 2 hour 1 hour hr. hr. Proposed Material and Construction 1/4 kw 7 4 2 5 ) ( - 1 - t j 1 Y 4 i - 5-r1123 3. Duct enclosures shall be separated from the duct by at least 3 and not more than 12 inches. Proposed in. 4. Duct enclosure shall be sealed around the duct at the point of penetration and vented to the exterior through a weather- protected opening. 5. Duct enclosures shall serve only one kitchen exhaust duct. 6. Tight - fitting access openings shall be provided at each cleanout door. Access enclosure doors shall have a fire- resistance rating equal to the enclosure. L. Multiple hood venting 1. Number of hoods vented by a single duct system: A single duct system may serve more than one hood located in the same story of the building, provided that the interconnecting ducts do not penetrate any fire construction. 2. A hood outlet shall serve not more than a 12 -foot section of hood. Sheet 3 M. Additional information for Type 1 hood only: 1. Grease filters shall be installed at minimum 45 degree angle and equipped with drip tray and gutter beneath lower edge of filters. Proposed degrees. '2. Distance between lowest edge of grease filters and cooking surface of: Grill, fryer, exposed flame shall be not Tess than 2 ft. Exposed charcoal, charbroil shall be not less than 3 -1/2 ft. 3. Type I hood and duct shall have clearances from combustible construction of: UNPROTECTED Hood Min. Req. 18 in. Proposed in. Duct Min. Req. 18 in. Proposed in. 4. Hoods less than 12 inc es from ceilings or walls shall be flashed solidly. Flashing provided Yes n No Distance from ceiling in., wall in. 5. All joints and seams shall be made with continuous liquid -tight weld or braze made on the external surface of the duct system. Vibration insulation connector may be used provided it consists of noncom- bustible packing in a metal sleeve joint. 6. Centrifugal fans used for discharging grease exhaust shall be positioned in a bottom horizontal discharge position only. A duct that diverts the fan discharge shall not exceed 3 times the diameter of the fan outlets connected to the fan outlet. The duct shall be provided with an adequate drain opening at the lowest point to permit drainage of grease to a suitable collection device. 7. Fire extinguishers. Shop drawings shall be submitted to DCLU for Fire Department approval prior to field installation. References 1) Seattle Mechanical Code 1997 2) Director's Rule 5 -96 3) Seattle Building Code 1997 PROTECTED with 1 -Hour Fire -Rated Material Min. Req. 3 in. Proposed ° ' in. Min. Req. 3 in. Proposed 3 in. Proposed ft. Proposed ; r' ft. Sheet 4 O 0 (,) w • 0 ga D. a tu z w ~ n o. • co o ff wW 1 v O w z 0— z 1 Qty Inlet Sound Power by Octave Ban Lwa dBA Sates 82 125 - — 250 500 - 1 000 2000 4000 80 0 79 87 1 83 75 73 69 61 56 80 69 16.7 Qty Model Volume (CFM) SP lin. WC) FRPM operarinA per thp Motor Information Size (hp,) V/C/P Enclosure RPM 1 CUBE- 220-15 A. 5,250 0.75 845 1.46 1112 208/6013 OJP 1725 I 5 4 5 I`7 1 R I 51,..m•m7"+s. 1 IIIIihrim be- '` 41111 IIMENA IMEMII I 1 r INW i w. .. AM 111.1ilM111111 111111k.'M .0 4 t . 411:11.111.1P i IRIN 9 4- 01 %'. NM 11111111k sent ny: UUHSt & euMi ANY 206 284 4523; 10/12/01 1:0GPMl;JotFax_4560;Page 2/5 ffi Greenheck 10/12/01 Fan and Ventilator MARK: 5250 CFM NOTES: All dimensions shown are in units of inches Fan weight is without accessories DIMENSIONS Roof Opening (in.) 26.5 x 26.5 PERFORMANCE (Elevation ft. 0, Airstream Temperature •F = 70) SOUND 1.6 14 1S /.0 0 4 0.b 0.4 A2 0.0 0 eicennecr< CAPS 1.8.32 Appro. Fan Weight (lb.) 128 4,000 ;000 JOB: Al Construction naa 25.5 CUBE Belt Drive Exhaus Up t Fabiast n Centrifugal CONSTRUCTION FEATURES • Aluminum housing • Backward Inclined aluminum whed • Curb cap with prepunched mounting holes • Motor and drives Isolated on shock mounts • Drain trough • Ball bearing motors • Adjustable motor p,iliey • Adjustable motor plate • Fan shaft mounted in ball bearing pillow blocks • Bearings mee: or exceed temperature ratng of fan • Static resistant belts • Corrosion resistant fasteners SELECTED OPTIONS & ACCESSORIES Switch • Nema.1, Toggle, Mounted & Wired Meat Baffle ULIcUL -782 - "Parer Vent, for Rest. Exh. Appliances" Bearings with Grease Fittings 3,000 4,000 Volume pm 0,000 0,000 LwA. A weighted souna power level, based on ANSI S1.4. d13A • A weighted sound pressure level. based on 11.5 c6 anenuation per octave band at 5.0 tt Songs calculated using AMCA 301 at 5.0 ft. 1.000 16 1.4 12 1.0 00 0 0 0.4 0.2 111/O G1011011 11,1111.6e1(,111. 1GNI �•4 0.0 qtr Modal Volume (CFM) SP (in. WC) r IC Sst' Ar Motor Information — lilinelekl- IA Enclosure RPM 71 RSFP•150.15 4,725 0.25 557 1.13 I 208/6013 TEFC 1725 • ` / qtr Modal Volume (CFM) SP (in. WC) FRPM Operating Power (hp Motor Information Size (hp.) VICIP Enclosure RPM 71 RSFP•150.15 4,725 0.25 557 1.13 11/2 208/6013 TEFC 1725 62'3, Inlet • nd Power • y • - vIe - and Lwa 20x20 23 x23 250 50 f.. ... ... fs. • 0 :.• .. 77 71 7 8 73 73 1 65 80 69 16.8 I Damper Size (in.) Roof Opening (In.) Appro. an Weight (Ib,) 20x20 23 x23 250 • JOB: Al Construction ffl Greenheck 10/12/01 Fan and Ventilator MARK: 4725 10/01 NOTES: M dimensions shown are in units of Inches Fan weight Is without accessories DIMENSIONS PERFORMANCE (Elevation ft • 0, Airstream Temperature 'F = 70) SOUND 0.70 0.42 0..0 0.40 0.10 0.]0 0.10 0.00 C0006100.11 GAPS 1.4.3.2 • RS F p Filtered Louvered Roof Supply Fan CONSTRUCTION FEATURES • Exterior base panels, louver sections and insulated cover all of aluminum construction • Curb cap with prepunched mounting holes • Blower and motor assembly isolated on shock mounts • Forward curved stee: fan wheel • Adjustable motor pulley • Adjustable motor plate • Ball bearing motor • Fan shaft mounted In ball bearing pillow blocks Static free belts • Corrosion resistant fasteners SELECTED OPTIONS & ACCESSORIES Standard .1 In. Washable Aluminum Filters UL/cUL•705 - "Power Ventilators" 0 1,000 2.000 V.wm. (CFM) LwA • A weighted sound power level, based an ANSI S1.4. d8A • A weightea sound pressure level, based on 11.5 dB attenuation per octa.e band at 5.0 ft. Sones calculated using AMCA 301 at 5.0 ft. 2.000 0020 1.4 13 10 0 . 4 1 0.. 1 0.4 0.2 au I Inu. GO ,., lnu LOnr"o, IOhM(,11TbN, ,oL SKIM 0.0 1 REGISTERED • AS PRO IDED 131' - LAW AS CONST COIsn CENErv• L. • • '••• • ..• • • ••• 7 . ' • . • REGIST.• f$ EXP DATE SCONS**022LS 06/15/2002 EFFECTIVE DATE . 06/10/2998 . . • - •S A * CONSTRUCTION . 27526 2611.i AVE S. • ;: FEDERAL' WAY.• VA • ); 003 • • • • sottiti c u/t44 .:cm bQ4JTMI5T iA.tv ANT.),p1TAUSTKE4 • MI6 ir: z 1 re aa JU UO co CD ILI W I . H WD N 3 u7 W z1.- 1- 0 Z 1- W U � co 0— 0 1- W W HF LLO w z s2 Z. /tit AC A■. Cd SDI�.. Its /2 hp p( fl J . Q(u l v P. (o(L ku.) ° ZiaE tY1/1 WoK 44204 41444' k0 L CIA A At&A '1oi E1l11 ' 4 (v))( to k> 4! ( r Mre i• A.A. ✓ , L EQUIPMENT SC$EDULE No Name /Size 1. Dining Table (30 "x30 "& 30 "x42 ") 2. Show Case 3. Cash Register 1. Ice Bin 3. Counter (30 "Wide) i. 2 Dr refrIgerator(47 "Lx30 "dx78 "h) ' Ice Maker (300 #) I, Tea Urn Sandwich Cooler (4'wx30'dx3'h) 0. Rice Cooker 1. Hand sink (13'dx17 "w) 2. Broiler ( 12 "x23 ") )6,' 'l'tO'2 13. Deep Fryer (16 "wx28 "dx3'h) 14. Range (3'wx32 "dx3'h) 15. Wok Unit (70 "Lx 41 "dx36"h) 16. Hood (45 "dx14'L) 17. Walk in Cooler (8'wx10'dx91 "h) 18. Clean Table (4' Lx 30 "d) 19. Dish Wash Machine (30 "x30 ") 20. Soiled / Pre -rinse Unit (6'Lx30 "d; 21. Work Table (30 "x4') 22. Veg. Sink (6'Lx28 "dx3'h) 23. Shelving 24 Employee Cabinet 25. 2 Dr Freezer (54 "wx30 "dx78 "h) 26. Mop (2'x2') M11-16 1St WkU. '9PO> t4b4 , r o).-.0g9 4KONAV ' kiv) v 4 ,/4 <' A l-Til4'tith<00 - 4617 W 0A sly ( 6c R <t4'> A`a. IiN>7 W 'Writ qt0ZAA-wm-041 1- a'1 bk -ouf 1x1 , ) u FY - &MA-t1Je) a & ( Pd 4Cb mffkI, S (upy 1,6la ew <1 S�IA1 ' 9f< pat, lam' ,t'•D" 4j a> O 0 13 0 0 v _ 1Z >fi Co m t 4.4e 0) 0 AO ON 2- At A 6,954 SF 16 1 1 11 111 1 hw c >�MU CO O. M 5 LO O N ,n /+t 5 .2G8 SF 7 7A 6,625 SF G\ltk(A , f> .arm efr Osam 'I1001.: :4Z4.1iiammo(istt:"s!" 11I1I!1III1IIiIiI!IftIii s '� i ... I � I I . pj tl 1'(o cki417 4(14 0 f t4«ot'1 'R i C ,la` i% Ikvk a4b 0 /( 'k /K 4"12C1 (( IYA C44049014 i i 4P/A(0114 roFP:150 *1v5 OM 0, tiq•" t 1 *My' -ft L.Lac0i, 39,088 SF �hbllo� 1t> LL111111111h�� FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con - tractors copy of approved plans acknowledged. By �Phf;Y,t-t„ t� r Date r� NOTES PennftNo. M - pea 1. THE EXHAUST & MAKE UP AIR SYSTEM SHALL BE CONNECTED BY AN ELECTRICAL INTERLOCKING SYSTEM. 2. ALL EQUIPMENTS SHOWN ON THIS DRAWING SHALL BE AS SPECIFIED OR EQUAL. 3_ THE PROPOSED WALL TO BE CONSTRU(- 1113 TO MEET THE FIRE CODES FOR TYPE I HOOD IN LEU OF MINERAL WOOL PAD( 1 1111 FIRE RESISTIVE SHIELD.). 4. STAINLESS STEEL SHEETS SHALL BE COVERED THE ENTIRE COOKING AREA AND 18" EXTENDED TO NON- COMBUSTION WALL AREA. 5. ALL HOOD AND DUCT JOINS & SEAMS SHALL BE EXTERNAL GREASE TIGHT WELDED. 6. EXHAUST FAN AND MAKE UP FAN SHALL BE 24"(MIN) DISHARGE ABOVE ROOF. 7. MNINUM DISTANCE BETWEEN EXHAUST FAN & MAKE UP FAN SHALL BE NOT LESS THAN 10'. 8. HOOD FIRE SUPPRESSION SYSTEM BY OTHER PERMIT. The Scope of this Proiect This project is a tenant improvement project from a retail space ( jewelry store) to change to a Thai restaurant. Including the following items: 1. Floor plan 2. Hood system plan 3. Electrical system plan 4. Plumbing plan. The existing structure, floor, ceiling, wall, HVAC, parking space, & doors are remained unchanged. , REVISIONS Iv •! ;:L j CITY OF TUKWILA BUILDING DiVI^ ON KO CHANGES SHALL BE MADE TO FccpE OF VFORK WITHOUT PRIOR DVAL OF TUKWILA BUILDING DIVISION, `!] F R!_NS WILL REQUIRE A FEW RAN SUBMIT. GM' IDOtRA APPROVED MAY 15 2192 CAM ILA 4 P , 5 ?..7p PERLaf c8 , PROJECT INFORMATION Name SWEET BASIL restaurant Footage: 2464 SF Location: 16876 south center pkwy, TUKWILA WA 98188 Tenant Denchai SUNTI, 206 - 234 - 4662 Address: 743 Melody Lane, Edmond, WA 98020 Property Owner : Gregory D. CLOSE, 425 - 990 -6200 Address: 600 108th Ave., NE Suite 530, Bellevue WA 98004 Designer : ` Thomas LI 253- 973 -8500 Address: 10609 Rowland Ave. SW Lakewood WA 98499 CONTRACTOR: S. A. Construction, Kevin TA 206 - 329 -8430 Address: 812 S Rainier Ave., Seattle WA 98144 #SCONS * *022LS TAX ID: 21920/1 .419.4 O 1\10.1 CONSTRUCTION' TYPE: WOQT7 \L Y SEIMIC: ZONE: Commercial OCCUPANCY: •