City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2623049129 Permit Number: MO2 -089
Address: 16876 SOUTHCENTER PY TUKW Issue Date: 05/22/2002
Suite No: Permit Expires On: 11/18/2002
Tenant:
Name: SWEET BASIL RESTAURANT
Address: 16876 SOUTHCENTER PY, TUKWILA, WA
Owner:
Name: CAPITAL & COUNTIES USA
Address: 101 CALIFORNIA ST #2525, SAN FRANCISCO CA
Contact Person:
Name: THOMAS LI
Address: 10609 ROWLAND AVENUE SW, LAKEWOOD, WA
Contractor:
Name: S A CONSTRUCTION Phone: 253 973 -8500
Address: 27526 26TH AVENUE SOUTH, FEDERAL WAY, WA
Contractor License No: SCONS * *022LS Expiration Date: 06/15/2002
DESCRIPTION OF WORK:
INSTALLATION OF A COMMERCIAL KITCHEN HOOD, INCLUDING AN EXHAUST FAN, AIR
MAKE -UP FAN AND DUCT SYSTEM
Value of Construction:
Type of Fire Protection:
Permit Center Authorized Signature:
Signature:
Print Name:
doc: Mech
$ 7,500.00
N/A
.gNer(A ( 51 JNT l
MECHANICAL PERMIT
Phone: 415 421 -5100
Phone: 253 973 -8500
Fees Collected:
Uniform Mechnical Code Edition:
lA i U2 Date: 5 ' a ”"Q Z
MO2 -089
$68.88
1997
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construct)on or the performance of work. I am authorized to sign and obtain this mechanical permit.
Date: S12 2/U 2_
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
Printed: 05 -22 -2002
DEPARTMENTS:
ACTIVITY NUMBER: MO2 -089
PROJECT NAME: SWEET BASIL RESTAURANT
SITE ADDRESS: 16876 SOUTHCENTER PARKWAY
XX Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
DATE: 04 -18 -02
Revision # After Permit Is Issued
Buildin s
Public orks 1✓ C _
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Fire
Struf
ctural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
Planning Division
Permit Coordinator
DUE DATE: 4 -23-02
x
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route [Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 5 -21 -02
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
Oocumentskouting stip.doc
2-28-02
kLRMIT COORD COPY
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
ACTIVITY NUMBER: MO2 -089 DATE: 04 -18 -02
PROJECT NAME: SWEET BASIL RESTAURANT
SITE ADDRESS: 16876 SOUTHCENTER PARKWAY
XX Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Is Issued
DEPARTMENTS:
Building Division
Public Works
Documents/routing slip.doc
2.28.02
APPROVALS OR CORRECTIONS:
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
TUES /THURS RO TING:
Please Route ' Structural Review Required ❑ No further Review Required
REVIEWER'S NITIALS::.,f
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
Planning Division
❑ Permit Coordinator ❑
DUE DATE: 4-23-02
Complete pgf Incomplete ❑ Not Applicable ❑
Comments: i,,4 ) comp(O . dfitOlb,
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
DATE: 4
DUE DATE: 5-21-02
❑
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
•
PERMIT NO.: MO 2 089
MECHANICAL PERMIT APPLICATIONS
INSPECTIONS
❑ 2 Pre- construction
❑ 50 WSEC Residential
❑ 60 WA Ventilation/Indoor AQC
❑ 610 Chimney Installation/All Types
❑ 700 Framing
❑ 1080 Woodstove
❑ / 1090 Smoke Detector Shut Off
1100 Rough -in Mechanical
❑ 1101 Mechanical Equipment/Controls
❑ 1102 Mechanical Pip /Duct Insul
❑ 1105 Underground Mech Rough -in
❑ _ 1115 Motor Inspection
1400 Fire - Final
1800 Mechanical - Final
4015 Special -Smoke Control System
CONDITIONS
10001 No changes to plans unless approved by Bldg
Div
10002 Plumbing permits shall be obtained through King
Co
10003 Electrical permits obtained through L & I
10005 All permits, insp records & approved plans
available
10014 Readily accessible access to roof mounted
equipment
9,) 10016 Exposed insulation backing material
10019 All construction to be done in conformance
w /approved plans
10027 Validity of Permit
10036 Manufacturers installation instructions required
on site
❑ 10041 Ventilation is required for all new rooms &
spaces
❑ 10042 Fuel burning appliances
❑ 10043 Appliances, which generate....
❑ 10044 Water heater shall be anchored....
Additional Conditions:
TENANT NAME: S P\LSTA utzp, !J T
FEES
Basic Fee (Y/N)
Supplemental Fee (Y/N)
Plan Check Fee (Y/N)
Furnace/Burner
to 100,000 BTU (qty)
Over 100,000 BTU (qty)
Floor Furnace (qty)
Suspended/Wall/Floor - mounted Heater (qty)
Appliance Vent (qty)
Heating/Refrig/Cooling Unit/System (qty)
Boiler /Compressor
to 3 HP /100,000 BTU (qty)
to 15 HP /500,000 BTU (qty)
to 30 HP /1,000,000 BTU (qty)
to 50 HP /1,750,000 BTU (qty)
over 50 HP /1,750,000 BTU (qty)
Air Handling Unit
to 10,000 cfm (qty)
over 10,000 cfm (qty)
Evaporative Cooler (qty)
Ventilation Fan (qty)
Ventilation System (qty)
Hood (qty)
Incinerator — Domestic (qty)
Incinerator — Comm /Ind (qty)
Other Mechanical Equipment (qty)
Other Mechanical Fee (enter $$)
Add'1 Fees — Work w/o Permit (Y/N)
Insp Outside Normal Hours (hrs)
Reinspections (hrs)
Miscellaneous Inspections (hrs)
Add'I Plan Review (hrs)
Plan Reviewer,
Permit Tech:
Date: ✓ l Sil CZ
Date: 6- jV v Dv
Ug
N W.
WD
2 QQ
u-Q
N 3
O
111 �
• 0
• c
0 ;
1—
W W.
F
U N
O
Z
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: MO2 -089
PROJECT NAME: SWEET BASIL RESTAURANT
SITE ADDRESS: 16876 SOUTHCENTER PARKWAY
XX Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
DATE: 04 -18 -02
Revision # After Permit Is Issued
DEPARTMENTS:
Building Division ❑
Public Works ❑
Complete ❑
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2-28-02
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete
Planning Division
Permit Coordinator
DUE DATE: 4 -23-02
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE. LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route ❑ Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
DUE DATE: 5 -21-02
DATE: % O? 3 - Oa
❑
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: A_ -� /h
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Project Name/Tenant:$ / L 1 Q5r / R-es�a ol. rer /71-
( G / / �1 T
Value o7�� al Equipment:
Site Address : G 7 //� � � /�� City Stat �}/ -i
Tax Pa c ,(
Property O nen
�r etor
rJDyE
Signature:,
Phone: ( ) /
- ?�S " — f9' d - /,200
Syyeet Addres s:
44
_ #P
Cit State/Zip:
Fax #: ( )
Contractor 4.. /
Print name:
76 L )
Phone: ( )
Phone: (
Street Address: 4
Ain_ C Zip:
Fax ) grr i, 74 T
Contact Person:
�/�as
G l
t
Phone: ( )
3 -r73 - -RS
F�jdd
/ Obf� �c&.D .4hI/f
,�p
W zejezua�
,�jtyS
Fax ( q41 /
'
4BUlIDINGfO
�E'R.:ORAU.THOR/ZED1'CENV: 1
" ..
Signature:,
Date:
/g / e>2___
Print name:
76 L )
Phone: (
_
Fax #:
! �/r
Add / 7
�Dh/Dr✓srGI 41- PI
t
City /State/Zip:
4t
JM WI
q 5
CITY OF T(KWILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Project Number:
Permit Number:
',1 11I IN ONIY
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
f, Y1 EdiiA
AIJP i:RMITrREVIEW AND AP.PROWAL REQUESTEDe (TOrBE "F /LL' D;OUTBVAPPL /CANT)`, `,
Description of work to be done (please be specific):
/rJO � /�� i ark A c leY e map
‘eiz, P. a cts`f kl • A.- emote y /t-Yt, K 1.t e ,
11/2/99
meth pernadoc
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application accepted:
y -/er do
Date application expires:
Application taken by: (initials)
z
w
re
0
0
U)
U) u_
WO
2
LL <
to
d
I-
z =
I— O
W H Ljj
D 0
0
O
0 F-
W
H
IL O
.z .
W
U=
H�
O
z
✓
Submittal Rvquirentwtls
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening
Heat Loss Calculations or Washington State Energy Code Form #H -7
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for new and the replacement of existing roof equipment
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer.
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
RESIDENTIAL: Two complete sets of attachments required with application submittal
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
Submittal Requirements
New Single Family Residence
Heat Toss calculations or Form H -6.
Equipment specifications.
11/2/99
mtscpmt.doc
Change -out or replacement of existing mechanical equipment
Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition.
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
City fr
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
Parcel No.: 2623049129 Permit Number: MO2-089
Address: 16876 SOUTHCENTER PY TUKW Status: ISSUED
Suite No: Applied Date: 04/18/2002
Tenant: SWEET BASIL RESTAURANT Issue Date: 05/22/2002
1: ** *BUILDING DEPARTMENT * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by
that agency, including all gas
piping (296 - 4722).
4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be
inspected by that agency
(206- 835 - 1111).
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These
documents are to be
maintained and available until final inspection approval is granted.
6: Readily accessible access to roof mounted equipment is required.
7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as
amended, Uniform Mechanical Code
(1997 Edition), and Washington State Energy Code (1997 Edition).
8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a
permit for, or an approval
of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to
give authority to violate
or cancel the provisions of this code shall be valid.
9: Manufacturers installation instructions required on site for the building inspectors review.
10: ** *FIRE DEPARTMENT CONDITIONS * **
11: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10.
12: Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking application shall be
protected by an approved automatic
extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is
automatically shut off to
all equipment under the hood, when the system is actuated. (UFC 1006)
13: A wet chemical portable fire extinguisher having a minimum rating of 2A:1B:C:K shall be installed within 30 feet of commercial
food heat - processing equipment,
as measured along an obstructed path of travel. (UFC 1006.2.7).
14: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72
15: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City
Ordinance #1900.
16: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems.
(NFPA 72 -1- 5.5.4)
17: Local U.L. central station supervision is required. (City Ordinance #1900)
18: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention
Bureau. No work shall commence
until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3)
19: Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance
#1900)
20: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire
doc: Conditions
MO2 -089 Printed: 05 -22 -2002
i
City o fr l ik.1
a
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Alarm" or "Fire Alarm Control ".
(City Ordinance #1900)
21: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2))
22: In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to
provide notification of fire at
that location. (NFPA 1 -5.6)
23: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for
access shall be placed in the
lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. (City Ordinance #1900).
24: ** *ELECTRICAL * ** UFC Article 85 - NPFA 70 - NEC
25: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide
access to the panel and 30
inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c))
26: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22)
27: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70)
28: Doors into electrical control panel rooms shall be makred with a plainly visible and legible sign stating "ELECTRICAL ROOM" or
similar approved wording. (UFC
8509.3)
29: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such
condition or violation.
30: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-
4407.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature:
Print Name: Te hC)LCL �JY+ 1
doc: Conditions
MO2 -089
Date: -- V2Z Uz—
Printed: 05 -22 -2002
Payee: SWEET BASIL
TRANSACTION LIST:
ACCOUNT ITEM LIST:
doc: Receipt
Af
City of T ukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Current Pmts
Amount
Payment Cash
MECHANICAL - NONRES
PLAN CHECK - NONRES
RECEIPT
Type Method Description
Parcel No.: 2623049129 Permit Number: MO2 -089
Address: 16876 SOUTHCENTER PY TUKW Status: APPROVED
Suite No: Applied Date: 04/18/2002
Applicant: SWEET BASIL RESTAURANT Issue Date:
Receipt No.: R020000689 Payment Amount: 68.88
Initials: KAS Payment Date: 05/22/2002 02:52 PM
User ID: 1684 Balance: $0.00
68.88
Description Account Code
000/322.100 55.10
000/345.830 13.78
Total: 68.88
Printed: 05 -22 -2002
sect:
c,u - � a r�4 v
Typ f inspyection:
f- d uc
tdrI7 Date
5.c. ri< I I
called:
Special structions:
Date wanted p n.
/ � ��
Re er:
rin ki
Pho : 0) tf IC. 3
I . 3
INSPECTION NO.
•CITY OF,TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila WA 98188
INSPECTION RECORu
Retain a copy with permit
;')'9)
•
PI Da -O.g , )
ER IT NO. /�'�/
(206)431 -3670
Approved per applicable codes. fl Corrections required prior to approval.
COMMENTS:
$47.00 REINSPECTION EQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call t� schedule reinspection.
Receipt No:
Date:
•
(206)431-3670
Type of Inspection:
Date Wanted:
Requ ter:
: .:IN S PECTION REC
Retain a copy with permit
INSPECTION NO. •
ITV OF TUKWILA BUILDING DIVISION
300Southcenter131vd., #100, Tukwila, WA 98188
Approved per applicable codes.
COMMENTS:
rod used -coy V‘ood
VIIAS ( ct -e-or
• f.fAcit4z. or 0, votlick
\
S4-civvrck n pp r OCil 1
I t
-4-' ow f riCre IAC)nd
2-0A'Gt
tit "">icstf %An -CtAr (..U0/4114,
- -e \va.. ssue
- v;:e eirs
VO•PtA4 40 Int
o A r))0si
.." •
Inspector:
4,14 4"
IT 0
orrections required prior to approval.
Date: o it _ 02
$47.00 REINSpECTION FEE REQUIRED. Prior to inspection, fee must be
paid at300Southcenter Blvd., Suite 100. Call to schedule reinspection.
r eceipt No.:"
'Date:
Project:.. :: .. /
,U16 -• .. /L k T
Type of Inspection:
- / Ai ) c 0
&Ugh -
Addres ::
e .76 :S urqo,e P
Date C d: a
Y - 6 - o�
Special Instructions:.
)_ %/...':-... • }
.eli.,``7.::< . ,
�Q .
L
Date W nted:
7 —q ....c=
m
p.m.
Requester:
PONN5
Phone No: ■
INSPECTION RECcD
Retain a copy with permit
INSPECTION NO:
ITLOF TUKWILA BUILDING DIVISION
300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
O.
PE
T
(206)431 -3670
COMMENTS:
GlX
c ii g:,v47-7
7�
% 4. % ' /
z .ie y 1 .. /r
(l 1 / /4-7 e-47,
Corrections required prior to approval.
$47.00 REINSPECT • N FEE REQUIREfti. Prior to inspection, fee must be
.paid at 1300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
R No. :.
IDate:
City of Tukwila
Project Name !�'� e-4 aqs i 0 P3"iCt4.' "
Address /(, «- � • P
Retain current inspection schedule
Needs shift inspection
Y Approved without correction notice
1 y 47.77 :k
Fire Department Thomas P. Keefe, Fire Chief
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct: Y
Halon:
Monitor: rr- - -
Pre -Fire:
Permits:
fi r / ; 11
Authorized Signature
FINALAPP.FRM Rev. 2/19/98
Steven M. Mullet, Mayor
Permit No. A101• "
Date
Suite #
T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206-575-4439
Public Health
Seattle & King County
HEALTHY PEOPLE. HEALTHY COMMUNITIES.
Alonzo L. Plough, Ph.D., MPH, Director and Health Officer
April 12, 2002
Thomas Li
Al Construction
10609 Rowland Avenue SW
Lakewood, WA 98499
RE: Sweet Basil
16876 Southcenter Pkwy
Tukwila, WA 98188
Dear Mr. Li:
We have approved the plans for your food service establishment.
Your establishment has been assigned the following business identification number
(SR#1034544). Please use this SR# in all future contact with us.
Before you open for business, you must complete the enclosed application for a permit and return
with the correct fee of ($318.00) for a (6301) permit. If you open before you obtain your permit,
your permit fee will be double.
Before you open you need to schedule a pre - operational inspection by the Health Department.
Although your application for a food service establishment permit from Public Health Seattle and
King County will be approved during this inspection, you may need to obtain additional permits
or approvals from other agencies. It is the responsibility of the food service establishment
operator /owner to obtain all necessary permits and approvals. Operating the establishment
without these required permits or approvals may subject you to legal action by the appropriate
agencies. If you open without health inspection, you may be closed. Once your plumbing permit
has been finalized, contact me at (206) 205 -1903 to schedule the
pre- operational inspection. Failed pre - operational inspections will require a $100.00 fee for a
repeat inspection. Be sure all other business inspections are done (plumbing, building, etc.)
before you call for your Health Department inspection.
Sincerely,
(9g
Mike Milbach
Plans Examiner
MM:dg
Enclosure
v
Alder Square Environmental Health Services
1404 Central Avenue South, Suite 101 • Kent, WA 98032
T (206) 296 -4708 F (206) 296 -0163 • www.metrokc.gov /health
WA%
RECEIVED
CITY OF TUKWILA
APR 1 8 2002
PERMIT CENTER
o
Moe - o89
City of Seattle ® King County
Gregory J. Nickels, Mayor Ron Siren, Executive
•
Z
re 2
0
0
rn
� O
w
Q .
52 a
w
D
O -
O I-
= w
1— F.:
u_
li z
=
z
COMMERCIAL KITCHEN HOOD WORK SHEET/ CHECK LIST
Two copies of this worksheet/checklist must accompany plan sets submitted with commercial kitchen range hood
permit applications. It explains and organizes information needed by the Department of Construction and Land
Use to efficiently review plans and issue permits. DCLU will keep this document as part of the permanent project
the and will use it to verify code compliance. The applicant is responsible for assuring the accuracy consis-
tency of the information. (� T3A 5) L <z /.
A. Project Address: I C9 d 7 4 d c-! 77, rr /Tr P tA/ Y l U /& )i L f � � /c &
B. Established use and history of building
Is it an existing restaurant, food processing area or food service area? n Yes FfNo
If no, provide construction or change of use permit number
C. Location of exterior ductwork and mechanical equipment
1. Is ductwork or mechanical equipment located outside of building other than roof top? ri Yes No
2. Applicant shall provide plan and elevation views showing ductwork, duct enclosure, hood, cooking
surface air supply, exhaust system, and equipment support system including structural framing detail
(Examples 1, 2, and 3).
D. Type of Hood
1. For grease and smoke removal:
(Example: deep fryer, charbroilers, grill and roasting ovens)
2. For steam, vapor, heat or odor removal:
(Example: steamer, pastry and pizza oven).
Hood shall have a permanent, visible label identifying
E. Type of material and gage
TYPEIHOOD
Duct and
Ple,wm
Hood
Flashing
3. Is hood for solid fuel cooking equipment?
If yes, a separate exhaust system is required.
Type of Material Gage
Min. Req. Proposed
Stainless Steel
Galvanized Steel
Stainless Seel
Galvanized Steel
Stainless Steel
Galvanized Steel
18 Ga. Ga.
16 Ga. . Ga.
LC Ga. .1
22 Ga. Ga.
22 Ga. ZZ Ga.
22 Ga. Ga.
it as a Type II hood.
RECEIVED
CITY OF TUKWILA
APR 1 8 2002
PERMIT CENTER
August 1998
Type I 1 Quantity
Type II
Quantity
Yes ZNo
TYPE II HOOD
Gage
Min. Req. Proposed
24 Ga. Up to 12" dia. Ga.
22 Ga. Up to 30" dia. Ga.
24 Ga. Up to 12" dia. Ga.
22 Ga. Up to 30" dia. Ga.
NOT REQUIRED
2.z Ga. Gu.
24 Ga. Ga.
MOZO89
Sheet 1
F. Quantity of air exhausted through the hood
CANOPY HOOD
Hood shall extend beyond cooking surface
on all open sides not less than Min. 6" Proposed !o in.
Distance between lip of hood and edge of
cooking surface shall not exceed Max. 4' Proposed?' ft.
Cooking surface area = X
Hood area (A) = X
TYPE I (N = 4 Q= 150A = 150 X
HOOD (N = 3 or less Q = 100A = 100 X
TYPE II (N = 4 Q = 75A = 75 X
HOOD (N = 3 or less Q = 50A = 50 X
H.
Type Air Velocity CFM /Duct Area (Ft
of Hood (FPM)
Z ft2
cfm
= %' a cfm .
cfm.
cfm.
G. Exhaust duct system
1. Applicant shall provide the specified air velocity in exhaust d ct.
2. Duct size in. x . 1 8 in.,.duct area = in. x
144
NON- CANOPY HOOD
N = no. of hood sides exposed
0 = quantity of air
A = area of hood in ft
L = lineal feet of the front
cooking equipment surface
Q =300L
Q = 300 X = cfm.
Q = 150L
Q = 150 X = cfm.
in = ft
Proposed Air
Velocity
I Req. 1500 to 2500 "� � � / . 7 4 3 FPM
II Recom. 500 to 2500 /
2. Static pressure loss
duct in. + grease filters /extractor
Static pressure
Exhaust outlet location
1. Exhaust outlet shall terminate above roof
in. at
Extend above roof
Distance from same or adjacent building
Distance above adjoining grade
Distance from property line
Distance from windows and doors
Distance from mechanical air intake
Distance of duct above adjoining grade at alley
2. If exhaust outlet terminates at exterior wall, provide cleaning equipment.
See Director's rules 5 -96.
FPM
in. + other in. = Total in. of H
3. Fan and Motor shall be of sufficient capacity to provide the required air movement. Fan motor shall not
be installed within ducts or under hood.
71 0(4
Fan make and model /.;2 4 s 941,7 HP •
1 14 d cfm.
Min. required
24 in.
10 ft.
10 ft.
10 ft.
10 ft.
10 ft.
16 ft.
Li Yes
Proposed
in.
ft.
ft.
ft.
ft.
ft.
ft.
No
Sheet 2
I. Makeup air
1. Applicant shall provide makeup air not less than 90% of the exhaust. 17i cfm.
2. Makeup air system shall be electrically interlocked with the exhaust system, such that the makeup air
system will operate when the exhaust system is in operation. Provide note on plan sheet no.
3. Makeup air shall be provided by a fan or motorized damper of sufficient capacity. Windows and door
openings shall not be used for the purpose of providing makeup air.
4. If more than 2500 cfm supplied to the space other than the hood, provide heater capable of heating
makeup air supplied to the space to 65 degrees F .
Heater model # Input BTU Output BTU
Heater CFM AFUE
FAN t'Ciz - i;t)t( Vb .'F' \. 4 MOT RIZED DAMPER
Make and model H.P. Recommended air velocity,500 fpm
Static pressure ' /',3 & Ai 2 v/ in. at cfm. Duct area req. = cfm /500 fpm /500 = ft
Duct Dimension A fix /,ir' , area � j, 0(Q2 ft Duct. Dimension req. = •
Air velocity = cfm /area 4-1i' / . Dk E Eff. Damper opening X = ft2
= ‘ '‘// fpm
J. Slope of duct and cleanout access { l�
A
1. Horizontal duct Tess than 75' long min slope 1/4 in /ft proposed in /ft
more than 75' long • min slope 1 in /ft proposed in /ft
2. Tight- fitting cleanout doors shall be provided at
every change in ductwork direction.
K. Duct enclosure
Total no. proposed
1. Ducts penetrating a ceiling, wall or floor shall be enclosed in a duct enclosure from the point of
penetration to the outside air. A duct may only penetrate,exterior walls at locations where unprotected
openings are permitted by Table 5A of the 1997 Seattle Building Code.
• 2. For code compliance purposes, it is acceptable to assume that ducts penetrating concrete, brick or steel
ceilings, walls or floors shall require a 2 -hour fire - resistive duct enclosure, and for others, it shall be 1 hour.
Type of Const. Min. Fire- Resistive Proposed
Const. of Enclosure
IF.R., II ER
II, III, IV, V
2 hour
1 hour
hr.
hr.
Proposed Material and Construction
1/4 kw 7 4 2 5 ) ( - 1 - t j 1 Y 4 i - 5-r1123
3. Duct enclosures shall be separated from the duct by at least 3 and not more than 12 inches. Proposed in.
4. Duct enclosure shall be sealed around the duct at the point of penetration and vented to the exterior
through a weather- protected opening.
5. Duct enclosures shall serve only one kitchen exhaust duct.
6. Tight - fitting access openings shall be provided at each cleanout door. Access enclosure doors shall
have a fire- resistance rating equal to the enclosure.
L. Multiple hood venting
1. Number of hoods vented by a single duct system:
A single duct system may serve more than one hood located in the same story of the building, provided
that the interconnecting ducts do not penetrate any fire construction.
2. A hood outlet shall serve not more than a 12 -foot section of hood.
Sheet 3
M. Additional information for Type 1 hood only:
1. Grease filters shall be installed at minimum 45 degree angle
and equipped with drip tray and gutter beneath lower edge of filters. Proposed degrees.
'2. Distance between lowest edge of grease filters and cooking surface of:
Grill, fryer, exposed flame shall be not Tess than 2 ft.
Exposed charcoal, charbroil shall be not less than 3 -1/2 ft.
3. Type I hood and duct shall have clearances from combustible construction of:
UNPROTECTED
Hood Min. Req. 18 in. Proposed in.
Duct Min. Req. 18 in. Proposed in.
4. Hoods less than 12 inc es from ceilings or walls shall be flashed solidly.
Flashing provided Yes n No Distance from ceiling in., wall in.
5. All joints and seams shall be made with continuous liquid -tight weld or braze made on the external
surface of the duct system. Vibration insulation connector may be used provided it consists of noncom-
bustible packing in a metal sleeve joint.
6. Centrifugal fans used for discharging grease exhaust shall be positioned in a bottom horizontal
discharge position only. A duct that diverts the fan discharge shall not exceed 3 times the diameter of
the fan outlets connected to the fan outlet. The duct shall be provided with an adequate drain opening
at the lowest point to permit drainage of grease to a suitable collection device.
7. Fire extinguishers. Shop drawings shall be submitted to DCLU for Fire Department approval prior to field
installation.
References
1) Seattle Mechanical Code 1997
2) Director's Rule 5 -96
3) Seattle Building Code 1997
PROTECTED
with 1 -Hour Fire -Rated Material
Min. Req. 3 in. Proposed ° ' in.
Min. Req. 3 in. Proposed 3 in.
Proposed ft.
Proposed ; r' ft.
Sheet 4
O 0
(,)
w • 0
ga
D. a
tu
z
w ~
n o.
• co
o ff
wW
1 v
O
w z
0—
z
1
Qty
Inlet Sound Power by Octave Ban
Lwa
dBA
Sates
82
125
- — 250
500 -
1 000
2000
4000
80 0
79
87
1 83
75
73
69
61
56
80
69
16.7
Qty
Model
Volume
(CFM)
SP lin. WC)
FRPM
operarinA
per thp
Motor Information
Size (hp,)
V/C/P
Enclosure
RPM
1
CUBE- 220-15
A.
5,250
0.75
845 1.46
1112
208/6013
OJP
1725
I
5 4 5
I`7 1
R I
51,..m•m7"+s.
1
IIIIihrim
be- '`
41111
IIMENA
IMEMII
I
1 r
INW
i
w.
..
AM
111.1ilM111111
111111k.'M
.0
4 t . 411:11.111.1P
i
IRIN
9 4- 01
%'.
NM
11111111k
sent ny: UUHSt & euMi ANY 206 284 4523; 10/12/01 1:0GPMl;JotFax_4560;Page 2/5
ffi Greenheck 10/12/01
Fan and Ventilator MARK: 5250 CFM
NOTES: All dimensions shown are in units of inches
Fan weight is without accessories
DIMENSIONS
Roof Opening
(in.)
26.5 x 26.5
PERFORMANCE (Elevation ft. 0, Airstream Temperature •F = 70)
SOUND
1.6
14
1S
/.0
0 4
0.b
0.4
A2
0.0
0
eicennecr< CAPS 1.8.32
Appro. Fan
Weight (lb.)
128
4,000
;000
JOB: Al Construction
naa
25.5
CUBE Belt Drive Exhaus Up t Fabiast n Centrifugal
CONSTRUCTION FEATURES
• Aluminum housing • Backward Inclined aluminum whed • Curb cap with prepunched
mounting holes • Motor and drives Isolated on shock mounts • Drain trough • Ball
bearing motors • Adjustable motor p,iliey • Adjustable motor plate • Fan shaft mounted
in ball bearing pillow blocks • Bearings mee: or exceed temperature ratng of fan •
Static resistant belts • Corrosion resistant fasteners
SELECTED OPTIONS & ACCESSORIES
Switch • Nema.1, Toggle, Mounted & Wired
Meat Baffle
ULIcUL -782 - "Parer Vent, for Rest. Exh. Appliances"
Bearings with Grease Fittings
3,000
4,000
Volume pm
0,000
0,000
LwA. A weighted souna power level, based on ANSI
S1.4. d13A • A weighted sound pressure level. based
on 11.5 c6 anenuation per octave band at 5.0 tt Songs
calculated using AMCA 301 at 5.0 ft.
1.000
16
1.4
12
1.0
00
0 0
0.4
0.2
111/O G1011011
11,1111.6e1(,111. 1GNI �•4
0.0
qtr
Modal
Volume
(CFM)
SP (in. WC)
r
IC
Sst' Ar
Motor Information
—
lilinelekl- IA
Enclosure
RPM
71
RSFP•150.15
4,725
0.25
557
1.13
I
208/6013
TEFC
1725
•
` /
qtr
Modal
Volume
(CFM)
SP (in. WC)
FRPM
Operating
Power (hp
Motor Information
Size (hp.)
VICIP
Enclosure
RPM
71
RSFP•150.15
4,725
0.25
557
1.13
11/2
208/6013
TEFC
1725
62'3,
Inlet • nd Power • y • - vIe - and
Lwa
20x20
23 x23
250
50 f..
...
... fs. • 0
:.• ..
77
71
7 8
73
73 1
65
80
69 16.8
I Damper Size
(in.)
Roof Opening
(In.)
Appro. an
Weight (Ib,)
20x20
23 x23
250
•
JOB: Al Construction
ffl Greenheck 10/12/01
Fan and Ventilator MARK: 4725 10/01
NOTES: M dimensions shown are in units of Inches
Fan weight Is without accessories
DIMENSIONS
PERFORMANCE (Elevation ft • 0, Airstream Temperature 'F = 70)
SOUND
0.70
0.42
0..0
0.40
0.10
0.]0
0.10
0.00
C0006100.11 GAPS 1.4.3.2
•
RS F p Filtered Louvered Roof Supply Fan
CONSTRUCTION FEATURES
• Exterior base panels, louver sections and insulated cover all of aluminum construction
• Curb cap with prepunched mounting holes • Blower and motor assembly isolated on
shock mounts • Forward curved stee: fan wheel • Adjustable motor pulley • Adjustable
motor plate • Ball bearing motor • Fan shaft mounted In ball bearing pillow blocks
Static free belts • Corrosion resistant fasteners
SELECTED OPTIONS & ACCESSORIES
Standard .1 In. Washable Aluminum Filters
UL/cUL•705 - "Power Ventilators"
0
1,000 2.000
V.wm. (CFM)
LwA • A weighted sound power level, based an ANSI
S1.4. d8A • A weightea sound pressure level, based
on 11.5 dB attenuation per octa.e band at 5.0 ft. Sones
calculated using AMCA 301 at 5.0 ft.
2.000 0020
1.4
13
10
0 .
4 1
0..
1
0.4
0.2
au
I Inu. GO ,.,
lnu LOnr"o,
IOhM(,11TbN, ,oL
SKIM
0.0
1
REGISTERED • AS PRO IDED 131' - LAW AS
CONST COIsn CENErv• L. • • '••• • ..• • • ••• 7 .
' • . • REGIST.• f$ EXP DATE
SCONS**022LS 06/15/2002
EFFECTIVE DATE . 06/10/2998
. . • -
•S A * CONSTRUCTION .
27526 2611.i AVE S. • ;:
FEDERAL' WAY.• VA • ); 003 • •
• •
sottiti c u/t44
.:cm bQ4JTMI5T iA.tv ANT.),p1TAUSTKE4
•
MI6 ir:
z
1
re
aa
JU
UO
co
CD ILI
W I .
H
WD
N 3
u7
W
z1.-
1- 0
Z 1-
W
U �
co
0—
0 1-
W W
HF
LLO
w z
s2
Z.
/tit AC
A■. Cd SDI�..
Its /2
hp
p( fl J . Q(u l v P. (o(L ku.)
° ZiaE tY1/1
WoK
44204 41444'
k0
L CIA A At&A
'1oi E1l11 ' 4 (v))( to k> 4! (
r Mre i•
A.A. ✓ , L
EQUIPMENT SC$EDULE
No Name /Size
1. Dining Table (30 "x30 "& 30 "x42 ")
2. Show Case
3. Cash Register
1. Ice Bin
3. Counter (30 "Wide)
i. 2 Dr refrIgerator(47 "Lx30 "dx78 "h)
' Ice Maker (300 #)
I, Tea Urn
Sandwich Cooler (4'wx30'dx3'h)
0. Rice Cooker
1. Hand sink (13'dx17 "w)
2. Broiler ( 12 "x23 ")
)6,'
'l'tO'2
13. Deep Fryer (16 "wx28 "dx3'h)
14. Range (3'wx32 "dx3'h)
15. Wok Unit (70 "Lx 41 "dx36"h)
16. Hood (45 "dx14'L)
17. Walk in Cooler (8'wx10'dx91 "h)
18. Clean Table (4' Lx 30 "d)
19. Dish Wash Machine (30 "x30 ")
20. Soiled / Pre -rinse Unit (6'Lx30 "d;
21. Work Table (30 "x4')
22. Veg. Sink (6'Lx28 "dx3'h)
23. Shelving
24 Employee Cabinet
25. 2 Dr Freezer (54 "wx30 "dx78 "h)
26. Mop (2'x2')
M11-16 1St
WkU. '9PO>
t4b4 , r
o).-.0g9
4KONAV ' kiv) v 4 ,/4 <' A
l-Til4'tith<00 -
4617 W 0A sly
( 6c
R <t4'>
A`a. IiN>7 W
'Writ qt0ZAA-wm-041
1- a'1 bk -ouf
1x1 , ) u FY - &MA-t1Je)
a &
( Pd 4Cb
mffkI, S (upy
1,6la ew <1
S�IA1 '
9f< pat, lam' ,t'•D"
4j
a>
O
0
13
0
0
v _
1Z
>fi
Co
m
t
4.4e
0)
0
AO
ON
2-
At A
6,954 SF
16
1 1 11 111 1
hw c >�MU
CO
O.
M
5
LO
O
N
,n
/+t
5 .2G8 SF
7 7A
6,625 SF
G\ltk(A , f>
.arm
efr Osam 'I1001.: :4Z4.1iiammo(istt:"s!"
11I1I!1III1IIiIiI!IftIii
s '� i ... I � I I . pj
tl 1'(o cki417
4(14 0 f t4«ot'1 'R i C
,la` i% Ikvk a4b 0 /( 'k /K
4"12C1 (( IYA C44049014 i i 4P/A(0114 roFP:150
*1v5 OM 0, tiq•" t 1 *My'
-ft L.Lac0i,
39,088 SF
�hbllo� 1t>
LL111111111h��
FILE COPY
I understand that the Plan Check approvals are
subject to errors and omissions and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con -
tractors copy of approved plans acknowledged.
By �Phf;Y,t-t„ t� r
Date r�
NOTES PennftNo. M - pea
1. THE EXHAUST & MAKE UP AIR SYSTEM SHALL BE
CONNECTED BY AN ELECTRICAL INTERLOCKING SYSTEM.
2. ALL EQUIPMENTS SHOWN ON THIS DRAWING SHALL BE AS
SPECIFIED OR EQUAL.
3_ THE PROPOSED WALL TO BE CONSTRU(- 1113 TO MEET THE
FIRE CODES FOR TYPE I HOOD IN LEU OF MINERAL WOOL
PAD( 1 1111 FIRE RESISTIVE SHIELD.).
4. STAINLESS STEEL SHEETS SHALL BE COVERED THE
ENTIRE COOKING AREA AND 18" EXTENDED TO NON-
COMBUSTION WALL AREA.
5. ALL HOOD AND DUCT JOINS & SEAMS SHALL BE
EXTERNAL GREASE TIGHT WELDED.
6. EXHAUST FAN AND MAKE UP FAN SHALL BE 24"(MIN)
DISHARGE ABOVE ROOF.
7. MNINUM DISTANCE BETWEEN EXHAUST FAN & MAKE UP
FAN SHALL BE NOT LESS THAN 10'.
8. HOOD FIRE SUPPRESSION SYSTEM BY OTHER PERMIT.
The Scope of this Proiect
This project is a tenant improvement project from a retail space (
jewelry store) to change to a Thai restaurant. Including the following
items:
1. Floor plan 2. Hood system plan 3. Electrical system plan 4.
Plumbing plan.
The existing structure, floor, ceiling, wall, HVAC, parking space, &
doors are remained unchanged.
, REVISIONS
Iv •! ;:L j
CITY OF TUKWILA
BUILDING DiVI^ ON
KO CHANGES SHALL BE MADE TO
FccpE OF VFORK WITHOUT PRIOR
DVAL OF TUKWILA BUILDING DIVISION,
`!] F R!_NS WILL REQUIRE A FEW RAN SUBMIT.
GM' IDOtRA
APPROVED
MAY 15 2192
CAM
ILA
4 P , 5 ?..7p
PERLaf c8 ,
PROJECT INFORMATION
Name SWEET BASIL restaurant
Footage: 2464 SF
Location: 16876 south center pkwy, TUKWILA WA 98188
Tenant Denchai SUNTI, 206 - 234 - 4662
Address: 743 Melody Lane, Edmond, WA 98020
Property Owner : Gregory D. CLOSE, 425 - 990 -6200
Address: 600 108th Ave., NE Suite 530, Bellevue WA 98004
Designer : ` Thomas LI 253- 973 -8500
Address: 10609 Rowland Ave. SW Lakewood WA 98499
CONTRACTOR: S. A. Construction, Kevin TA 206 - 329 -8430
Address: 812 S Rainier Ave., Seattle WA 98144 #SCONS * *022LS
TAX ID: 21920/1 .419.4 O 1\10.1
CONSTRUCTION' TYPE: WOQT7 \L Y
SEIMIC: ZONE: Commercial OCCUPANCY:
•