Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M02-095 - RESIDENCE INN - BUILDING 11
M02 -095 Residence Inn Building 11 16201 West Valley Hy Z 1-1 0 N O v) W N LL W O gQ co 3 Z �. HO ZF- U • 0 U N OH WW • O Li;Z U N OF ( Value of Construction: Type of Fire Protection: The granting of this permi regulating constructio Signature: Print Name: doc: Mech City of 'lukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0005800006 Address: 16201 WEST VALLEY HY TUKW Suite No: Tenant: Name: RESIDENCE INN - BUILDING 11 Address: 16201 WEST VALLEY HY, TUKWILA, WA Owner: Name: TUKWILA HOTEL ASSOCIATES Address: PO BOX 3646, BELLEVUE WA Contact Person: Name: MICHAEL IVANCIC Address: 2112 116 AV NE, BELLEVUE, WA Permit Center Authorized Signature: the pe $27,000.00 SPRINKLERS ZV? MECHANICAL PERMIT Contractor: Name: K & D MECHANICAL INC Address: 1911 SW CAMPUS DRIVE, #321, FEDERAL WAY Contractor License No: KDMECI *008C) Permit Number: MO2 -095 Issue Date: 09/26/2002 Permit Expires On: 03/25/2003 Phone: Phone: 425 -451 -4084 Phone: 253 - 945 -8204 Expiration Date: 02/07/2004 DESCRIPTION OF WORK: REBUILD PORTIONS OF 8 UNIT BUILDING DAMAGED BY FIRE AND WATER DAMAGE. TO BE REBUILT FROM SLAB UP ALL 8 UNITS TO INCLUDE 8 HEATPUMPS, AND 8 WATER HEATERS. COMPLETE HVAC SYSTEMS INCLUDING VENTING, DUCT WORK, EXHAUST FANS, THERMOSTATS. Fees Collected: Uniform Mechnical Code Edition: Date: $430.88 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. oes not • resume to give authority to violate or cancel the provisions of any other state or local laws ance work. I am authorized to sign and obtain this mechanical permit. �%' Date: 1F 2- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -095 Printed: 09 -26 -2002 ACTIVITY NUMBER: MO2 -095 PROJECT NAME: Residence Inn Building 11 SITE ADDRESS: Response to Correction Letter # 16201 W Valley Hy DATE: 05 -01 -02 Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Is Issued DEPAR Building Division Fr Fire Prevention Auc S -Z�f_o Net_ 5 - 12 Public Works Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROUT G: PLAN REVIEW /ROUTING SLIP Incomplete ❑ Planning Division Permit Coordinator DUE DATE: 05-02-02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Route tructural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved U Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05 -31-02 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -26 -02 ACTIVITY NUMBER: MO2 -095 PROJECT NAME: Residence Inn Building 11 SITE ADDRESS: 16201 W Valley Hy Response to Correction. Letter # DATE: 05 -01 -02 X Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05-02-02 Complete g Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required E REVIEWER'S INITIALS: DATE: 6 - 12 , 1 0Z_ APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SUP Fire Prevention Structural Incomplete n Planning Division ❑ Permit Coordinator ❑ Not Applicable n DUE DATE: 05 -31 -02 Approved ❑ Approved with Conditions— Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: .4- Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2.28 -02 DATE: S — Li PERMIT NO.: (\\ O 2 - 09 MECHANICAL PERMIT APPLICATIONS INSPECTIONS R 2 Pre- construction 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 610 Chimney Installation/All Types ❑ 700 Framing ❑ 1080 Woodstove ❑ 1090 Smoke Detector Shut Off SI 1100 Rough -in Mechanical 1101 Mechanical Equipment/Controls 1102 Mechanical Pip/Duct Insul 1105 Underground Mech Rough -in 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final 4015 Special -Smoke Control System CONDITIONS 10001 No changes to plans unless approved by Bldg Div fig 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I 10005 All permits, insp records & approved plans available ❑ 10014 Readily accessible access to roof mounted equipment 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate. 14 10044 Water heater shall be anchored.... Additional Conditions: • N11.10 11,1PV ireAN TENANT NAME: 2a ck �'�, \�: a s FEES Basic Fee L Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Bumer to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/WallFloor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unh SSystem (q ty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP/1,750,000 BTU (qty) Air Handling Unit to 10,000 cfin (qty) over 10,000 cfin (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator – Domestic (qty) Incinerator – Comm/Ind (qty) Other Mechanical Equipment (qty) F3 Other Mechanical Fee (enter SS) Add'l Fees – Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Plan Reviewer: Permit Tech: — u Date: 4- 2 "'`j - 0 z- Date: 5 DEPARTMENTS: Building Division Public Works Complete C Comments: Please Route REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SUP ACTIVITY NUMBER: MO2 - 095 PROJECT NAME: Residence Inn Building 11 SITE ADDRESS: 16201 W Valley Hy K . Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 05 -01 -02 Revision # After Permit Is Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ n Planning Division Permit Coordinator n DUE DATE: 05-02-02 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Structural Review Required ❑ No further Review Required S/ DATE: S 1 DUE DATE: 05 -31-02 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -25.02 1- 00 � wo g? co 3 2 — O W D O O • (12 D I- • W • o O 0 O ~ Z Project Name/Tenant: .BIbEd -a-_ 1I- U t Wc. 31 Value of Mechanical Equipment: Site Address : City State/Zip: t41to1 W. VtiLtAy # td, tAWe -f TMKW ILA °r$tsf3 Tax Parcel Number: (.5 o G -77 4-a t vu, Property Owner: tta> c' -S USA. Phone: ( ‘ 1 ) 163s- Igoe) Street Address: 3 0z 12.0"1014— P o i l tt..id v A r a y PAL rsc City State/Zip: l-t r-t- , 334,FtD Fax #: ( ) 5 1.1 4 .59 - 7318 Contractor: Fax #: ( Phone: ( ) 7 � Street Address: City State/Zip: Fax #: ( ) �� Q �� Contact Person: t-hl.c1.1aEL Ivatr -tc.tc Phone: ( ) 1z5 4-5* l - 4 094. Street Address: City State/Zip: - Z-1 1 2.. I IG - rLA Av er 1..-1. RELLE E . Wid. 90C Fax #: ( ) 1 -1Z5 - 45i - 407,9 ;'BUIL'b %NC "OW �. Rd''41, O .' ,': ; 1 �' \`� Date: l ' / el / Print name: L , 1-.)t KI t E i EIj3E Phone: ( � (. — V-08 c-1, Fax #: ( z > ti-5t - (0 7 � Address: Z l_ ,. A . L Ciry /State/Zip: t3E LCE. V L t E. �� Q �� CITY OF T' 'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. I E .HANICAL',:PEtMiffiE IEW:ANOAPPROVA1:REC2UESTED ` (TO'BEALEDbUT , BYAPPLICANT) Description of work to be done (please be specific): Rt_ -aui po2-i(ota5 of 8-t-R- T I.tLot t7tlf-.li cFT2 81 F Ii2E WA.T Er.. ..Dg7-1ocj E.. 'TD RE RE ( LT 'R sLaLt Ui Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 1 Date application expires: Application taken by: (initials) 11/2/99 nech permii,doc ✓ .Submittal Requirements Floor plan and system layout pQ . Roof pl cal Code 504 e)) identify individual equipment and the location of each installation (Uniform NA , Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 1A.Ix• H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Y Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. 0, IN Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits 11/2/99 miscpmt.doc COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change -out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. Signature: Print Name: doc: Conditions City of 'Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0005800006 Address: 16201 WEST VALLEY HY TUKW Suite No: Tenant: RESIDENCE INN - BUILDING 11 PERMIT CONDITIONS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or Tess, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Manufacturers installation instructions required on site for the building inspectors review. 9: Water heater shall be anchored to resist earthquake (U.P.C. 510.5). I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the perfor ce of work. v ril l)ii vl t s Permit Number: MO2 -095 Status: ISSUED Applied Date: 05/01/2002 Issue Date: 09/26/2002 Date: MO2 -095 Printed: 09 -26 -2002 TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt City of 'Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0005800006 Address: 16201 WEST VALLEY HY TUKW Suite No: Applicant: RESIDENCE INN - BUILDING 11 Receipt No.: R020001416 Payment Amount: 430.88 Initials: SKS Payment Date: 09/26/2002 12:34 PM User ID: 1165 Balance: $0.00 Payee: K & D MECHANICAL Current Pmts Amount Payment Check 2320 MECHANICAL - NONRES PLAN CHECK - NONRES Type RECEIPT Method Description Description Account Code 000/322.100 344.70 000/345.830 86.18 Permit Number: MO2 -095 Status: APPROVED Applied Date: 05/01/2002 Issue Date: 430.88 Total: 430.88 Printed: 09 -26 -2002 Pr ct: ` e5/4-eince (Tfin - igitil Type of In ction: 1 Ad ress.. h. ID iia Date Call d: / 7 / 0 �` Special Instructions: Date Wanted: ° ;. ,r..., d 0 / ..m. Request . Ph UG. ! e9UCV f S7'/7 INSPECTION RECC'Th Retain a copy With permit • INSPECTION NO. CITY OF TUKWILA. BUILDING DIVISION ,6300.Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 igi Approved per applicable codes. Corrections required prior to approval. COMMENTS: 47.00 REINSPE paid at 6300 Sout Receipt No.: `` rw, + C T f € 4 C - t 1= ► r) ,a ( PERMI ?Cok a t cs. 0_e8.r'✓'.2 a T €_-1-e Date: .v� C 0 ) /0 g/05 ION FEE REQUIR . Prior to inspe tion, fee must be center Blvd., Suite 100. Call to schedule reinspection. IDate: COMMENTS: _ , 4r • ziA//7 ///3 Type of Inr, tiA 0 ap-Vdo Al s 4 /4 4 — rri , s 5 ■ •• t , 04- l) 1 T 1 6 6 21 Date Wanted) a z? _ 3 / .. 24‘i Pr- te / 1 / 3 PhoMo: _ 5 7/ 5v0 .r 6 /1A, e — # 1: 's 5 # 4 - "v e nal'e ear / • J.de- a / Aril* 4 ..) Od 4 7 li/t/-e° — /0 /..: ' A) 14/d ho 4- ;e0r- ?_/,.//7/„, • - -z/dvils- N . CZ 00 4 .ti e —An/ s /iv S ke,) NJ s 1.4.1 4 1-e-/ 7 s T a i1/) A ,t/Ch O 01-/-7 Siil t/Ah t) 49-01C_ P ject: ig I re5 - en e c .Lyn-81-16 // Type of Inr, tiA Arelo i / I , I Date Caied: — C7 ,9 / — ,0 Special Instructions: Date Wanted) a z? _ 3 / .. Requestere #0 PhoMo: _ 5 7/ 5v0 ( p. 7 INSPECTION RECCO Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 Date: 0. 206)431-3670 )". El Approved per applicable codes. Corrections required prior to approval. 47.00 REINSPECT • N FEE REQUI '. Prior to inspection, fee must.be paid at 6300 Southcenter Blvdz Sui e 100. Call to schedule reinspection. Receipt No.: IDate: COMMENTS: / 9, 145, ... 4 t Type of Inspection /---/ A e t' �t Z,/A/ /" / f e Z % ) : ea ve(c,vs» 4 / SY. /5 r • 006 1 I /✓S / /74l 44/A 77 4-.+4/4 .5 ,-.► -�, Date Wanted: / — Z2 - 03 ,4vi/w lit./ , -/ • Requester: 0 ; — v /5 2/i/ /7S / /2 90 //2y _ A'!}'I e "9 Ai lad✓`t° P Ject: ► S it falia' - -1N/(/ 8 /1 Type of Inspection /---/ A e t' Address: /G z0 / w, / t% / /e-ei Date Called: /- 2/ —U.� Special Instructions: Date Wanted: / — Z2 - 03 a.m. p.m. Requester: 0 ; — v Phone No: ■ 2 ab -5 7 -3 0 INSPECTION RECD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 20 • )431 -3670 Approved per applicable codes. Corrections required prior to approval. Date: /'- --e 47.00 REINSPECT! FEE REQUIRSO. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Sul 100. CaII to schedule reinspection. Receipt No.: 'Date: S- � -'--.v � 4X:f._±tM:i_i ��..$ *3'"�>i,el'+�'rtST. eta"' au1G�' 3i2�' Yi .�'h�Gdyi'*- C'1Si'.'S'ssiJ:..V .. �..'S:.'wr:.T =:u,`? r =.1 Project:. • /(J - ran e. - 1;/-.P5// Type of Inspection: 'Re 1 n S pe c13 cal /7J7 7 re / w v/, .5 .:fir ( Date��Ca: (s dal In . /2 r-61 1 f 1 co f ex I,, ai, ., -et h S Date Wanted: i a _1 -oa Requ er: i' Phon No: mo_- Approved per applicable codes. Inspecto INSPECTION REC Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Corrections required prior to approval. COMMENT& C c)rvr 'In�.� • TO In^ trP or4 44 /-- o h ‘ Date: ) 1 9_ 1 El $47.00 REINSPECTION FEE REQUIRED. Prior to, inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: PERM I A10. (► (21 6)431 -3670 Project: Type of Inspectio ems /`!" Addre" `' i � . v. a, Date Callec1 Special I structions: Date Wanted: a. . Requester: Phone No: •a14:k:.u INSPECTION REC Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PER j oo NO ( 06)431 -3670 El Corrections required prior to'approval. COMMENTS: /4 r/42:n9i■- //79t.7 - )-7 0 $47.00 REINSPECTION1 EE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No.: 'Date: r Projectap J44k Type of Inspection: /f�� " Addres : /6 et) /j g G Date Called: Special Ins ructions: / Date Wanted: /1 40 _ Requester: Phone No: Inspector: INSPECTION REC Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS' A ! / 2<3 d ,104 971 7a �r�f .� 4, ../Al /471A. r c /• r // c, /f cteako derild u / f1 1"/ / ✓' • ey /4'4 t1 S 7 L / ^.Cp At-Le cv 5-e 1 1 - , ./t `-C . airA — � - r $47. REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: {Date: (206)431 -3670 Prbject:t Ke5v1Q t q n C o n - B 1 -- . V1 I 1:: r "1" of Inspection: t)Oc le) — ‘ kn ltd 1 Jo u- \A ,( Date CallgE Special Instructions: Date Wantec: — — 0 Lt; .._,, a.m. Requester: r (Ac. Phone 20 2() '. 773 -a INSPECTION REC Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- 670 El Approved per applicable codes. .0 Corrections required prior to approval. COMMENTS: 4 riewk s 9 <=e ' c_rx." j .2*A 4 7. 9, Nod / 4;2_ <41_4. r<e 746, c hex/ tfik; io4 17 i4/0 iwi2.44 Inspector 2L 742 d 2-frz 1./..1e• // cee 7 1-- LS $47.00 REINSPECTIdI FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 041.,■1504:eP:::ef..411",i.fk Pro t: :;a• ' PAu ( Type of In ection: • i1 / , ti ,� / //� 7 s s. Date Called: cialvInstructions: : 1 , ;th 0194 Date Wanted: 1 / I aa..m.. Requester: i j 0 one No: c2 (— 57/ — 3 gS /O INSPECTION NO:' :,,, PERM fj'1 ITY TUKWILA BUILDING DIVISION 300 Southcenter :Blvd:, #100, Tukwila, WA 98188 (206)431 -3670 pr ca ' Approved: per: applicable codes. COMMENTS 1 � ^ �A C U c- � - C Cf 5 q! a t),c+ \; Pint obetA t�P�? , c rc1 -kCt Cu t nspector: INSPECTION RECO° Retain a copy with permit Corrections required prior to approval. `Date: 17_2 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be ':paid .at.6300.Southcenter Blvd., Suite 100. Call to schedule reinspection. luwastuarmagranormamenseMENEMM Z U 0 co u`l to w w W ° 2 oI w U lu) - O ms`s (M TS—. T t lTh T t G � Ct; n: -In re • 1d ���a w �Q I c. uy C1I5d:J (7 n / 04 f Da te Special Instructions: f Del ` 11 Date Wanted/ r `gym" Requester: n Phggeto: '' 57).. 36 I b INSPECTION REcd Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Me a ' v 9 Sl PER NO (206)431 -3670 p proved p er a pplicable codes. D Corrections required prior to approval. COMMENTS: y — J''t /�yi 1 - 4 , e - dZ rte, ( � L /) /.5) yam/ «LaU. ct-7"�4'�z ( ` Y+ '.t om' -f� $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No:: (Date: Month N NNE NE ENE E ESE SE SSE S January 16.1 16.1 16.1 53.6 129.0 183.4 230.6 251.9 257.9 February 21.4 21.4 36.9 112.4 175.7 229.5 253.9 260.9 262.5 March 27.1 27.1 91.8 159.2 217.2 242.8 253.0 243.7 238.0 April 33.0 68.6 137.1 195.3 225.5 239.1 225.9 204.4 192.1 May 37.3 105.1 162.3 210.6 229.9 225.1 199.4 170.1 154.1 June 51.1 117.6 171.4 213.7 226.9 216.7 186.9 154.0 137.4 July 39.4 104.2 161.3 207.5 222.7 220.4 195.6 165.7 151.0 August 34.8 65.4 134.3 187.4 219.3 230.1 218.4 197.6 186.3 September 28.2 28.2 86.3 145.2 203.9 232.3 242.6 235.6 227.9 October 22.1 22.1 36.4 105.4 171.4 216.2 245.2 253.6 252.2 November 16.3 16.3 16.3 56.6 123.7 184.3 224.4 244.6 251.3 December 13.7 13.7 13.7 34.5 105.1 162.2 212.5 238.1 245.0 Month SSW SW WSW W WNW NW NNW HOF Mult January 251.9 227.1 188.2 121.9 59.5 16.1 16.1 92.5 1.00 February 262.5 255.6 227.5 179.4 105.7 . 40.2 21.4 147.6 1.00 March 244.1 251.9 247.4 210.6 163.3 87.7 27.1 199.6 1.00 April 204.0 224.1 238.5 228.6 194.9 132.9 70.0 238.0 1.00 May 169.6 197.8 223.8 231.1 208.5 165.6 103.6 259.3 1.00 June 152.9 185.9 214.0 228.2 209.8 175.3 113.9 265.4 1.00 July 164.4 194.2 217.4 226.5 202.6 164.4 101.1 257.6 1.00 August 197.1 216.1 229.9 220.5 187.9 129.3 68.8 234.8 1.00 September 235.7 242.6 232.9 203.5 146.7 86.2 28.2 191.4 1.00 October 252.2 242.3 219.1 167.3 108.3 30.0 22.1 144.2 1.00 November 245.2 225.7 182.6 125.7 52.6 16.3 16.3 91.1 1.00 December 235.2 212.0 163.5 105.1 33.6 13.7 13.7 69.9 1.00 Project Name: Residence Inn Building 011 Tu. a Prepared by: Neir & Associates, Inc. Design Parameters City Name Location Latitude Longitude Elevation Summer Design Dry-Bulb Summer Coincident Wet -Bulb Summer Daily Range Winter Design Dry-Bulb Winter Design Wet -Bulb Atmospheric Clearness Number Average Ground Reflectance Soil Conductivity Local Time Zone (GMT +/- N hours) Consider Daylight Savings Time Daylight Savings Begins Daylight Savings Ends Simulation Weather Data Current Data is Design CIg Months Seattle IAP Washington 47 5 Deg. 122.3 Deg. 449.0 ft 85 0 °F 65 0 °F 18 3 °F 23 0 °F 19 2 °F 1 05 0 20 0 800 BTU /hr /ft/F 8 0 hours Yes April, 1 October, 31 ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑(❑❑❑❑❑) 1997 ASHRAE Handbook January to December Design Day Maximum Solar Heat Gains (The MSHG values are expressed in BTU /hr /ft ) Mutt. = User - defined solar multiplier factor. Carrier Hourly Analysis Program v4.04 n.. sign Weather Parameters & MSH's CIUY cO 1UKWIU APPROVED MAY 2 8 2002 \! CITY RECEIVED CITY NAY - 1 2002 PERMIT CENTER Moao 04/20102 03:50 PM Page 1 Project Name: Residence Inn Building 011 Prepared by: Neir & Associates, Inc. ical Occupancy (Fractional) Hourly Profiles: 1:Profile One Schedule Input Data Hour Value 00 100 01 100 02 100 03 100 04 100 05 100 08 100 07 100 08 100 09 100 10 100 11 100 12 100 13 100 14 100 15 100 16 100 17 100 18 100 19 100 20 100 21 100 22 100 23 100 Assignments: Design Jan 1 Feb 1 Mar 1 Apr 1 May 1 Jun 1 Jul 1 Aug 1 Sep 1 Oct 1 Nov 1 Dec 1 04/18/02 06:34 PM Carrier Hourly Analysis Program v4.04 Page 1 ,Protect Name: Residence Inn Building 011 TL a 'Prepared by: Neir & Associates, Inc. • Typical Thermostat (Fan / Thermostat) Hourly Profiles: 1:Profile One Schedule Input Data Hour Value 00 0 01 0 02 0 03 0 04 0 05 0 06 0 07 0 08 09 0 10 0 11 0 12 0 13 0 14 0 15 16 0 17 18 0 19 0 20 21 0 22 0 23 0 O = Occupied U = Unoccupied Assignments: Design Jan 1 Feb 1 Mar 1 Apr 1 May 1 Jun 1 Jul 1 Aug 1 Sep 1 Oct 1 Nov 1 Dec 1 04/18/02 06:35 PM • • Carrier Hourly Analysis Program v4.04 Page 1 Layers Thickness Density Specific Ht R -Valud Weight In lb/ft' BTU /Ib /F hr -ft= -F /BTU lb/ft' Inside surface resistance 0.000 0.0 0.00 0.685 0.0 5 /8 -in gypsum board 0.625 50.0 0.26 0.560 2.6 R -21 batt insulation 0.650 0.5 0.20 21.000 0.0 1 /2 -in gypsum board 0.500 50.0 0.26 0.448 2.1 Asphalt roil 0.063 70.0 0.36 0.153 0.4 Wood siding 0.500 37.0 0.28 0.817 1.5 not used - - - - - not used - - - - - not used - - - - - Outside surface resistance 0.000 0.0 0.00 0.333 0.0 Totals 2.338 24.00 6.6 Project Name: Residence Inn Building 011 Tu. Prepared by: Neir & Associates, Inc. Wall Layers Details (Inside to Outside) Wood Siding + Sheathinq + R -21 Batt Wall Constructions __ Wall Details Outside Surface Color Medium Absorptivity 0.675 Overall U -Value 0 042 BTU /hr /ft /F 04120102 02:35 PM Carrier Hourly Analysis Program v4.04 Page 1 re al U g N W, N W 0 g J, LL Q cy F ` 0 �, 0 I-- Ili la U u' O Ii z O ' Layers Thickness Density Specific Ht R -Value Weight lb/ft' in lb /ft' BTU /IbIF hr -ft' -F /BTU Inside surface resistance 0.000 0.0 0.00 0.685 0.0 5 /8 -in gypsum board 0.625 50.0 0.26 0.560 2.6 5/8 -In gypsum board 0.625 50.0 0.26 0.560 2.6 R -30 batt insulation 9.500 0.5 0.20 30.449 0.4 not used - - - - - not used - - - - - Not used - - - - - Not used - - - - - Not used - - - - - Outside surface resistance 0.000 0.0 0.00 0.333 0.0 Totals 10.750 32.59 5.6 Project Name: Residence Inn Building 011 Tula Prepared by: Neir & Associates, Inc. Cathedral + GWB + R - 30 Batt Roof Details Outside Surface Color Dark Absorptivity 0 900 Overall U -Value 0 031 BTU/hr/ft Roof Layers Details (Inside to Outside) Roof Constructions 0420102 02:35 PM Carrier Hourly Analysis Program v4.04 Page 1 Layers Thickness Density Specific Ht. R Value Weight lb/ft' in Ib /ft' BTU /Ib/F hr -W -F /BTU Inside surface resistance 0.000 0.0 0.00 0.685 0.0 5 /8 -in gypsum board 0.625 50.0 0.26 0.560 2.6 5 /8 -in gypsum board 0.625 50.0 0.26 0.560 2.6 R -30 batt insulation 9.500 0.5 0.20 30.449 0.4 Not used - - - - - Not used - - - - - Not used - - - - - Not used - - - - - Not used - - - - - Outside surface resistance 0.000 0.0 0.00 0.333 0.0 Totals 10.750 32.59 5.6 Project Name: Residence Inn Building #11 Tuk\ Prepared by: Neir & Associates, Inc. Truss /Flat + GWB + R - 30 Batt Roof Details Outside Surface Color Dark Absorptivity 0 900 Overall U -Value 0 031 BTU /hr /ft /F Roof Layers Details (Inside to Outside) Roof Constructions Carrier Hourly Analysis Program v4.04 0420/02 02:36 PM Page 1 Glazing Glass Type Transmissivity Reflectivity Absorptivity Outer Glazing 3/16" clear 0.810 0.083 0.107 Glazing #2 3/16" clear 0.810 0.083 0.107 Glazing #3 not used 1.000 0.000 0.000 1 .-. Project Name: Residence Inn Building 011 Tule& . Prepared by: Nair & Associates, Inc. Typical Window Window Constructions Window Details Detailed Input Yes Height 1 00 ft Width 1 00 ft Frame Type Vinyl Internal Shade Type None Glass U -Value 0 520 BTU /hr /ft /F Overall Shade Coefficient 0 714 Glass Details Gap Type 1/2" Air Space 04/20/02 02:36 PM Carrier Hourly Analysis Program v4.04 Page 1 • Typical Door Door Constructions Project Name: Residence Inn Building #11 Tukwila 0420/02 Prepared by: Neir & Associates, Inc. 02 :36 PM Door Details Gross Area 21 0 ft Door U -Value 0 600 BTU /hr /ft /F Z Glass Details Glass Area 0 0 ft Glass U -Value 0 580 BTU /hr /f 2 /F Glass Shade Coefficient 0 880 Glass Shaded All Day? No O N 0 N W; ca uj LL Q; 1 a; jr W Z � O 2p co 0 H tu W Z N ; O c Carrier Hourly Analysis Program v4.04 Page 1 Exp. Wail Gross Area (tt) Window 1 Qty. Window 2 Qty. Door 1 Qty. N 168.0 0 0 0 W 40.0 0 0 0 E 208.0 50 0 0 S 76.0 0 0 1 Space Input Data Project Name: Residence Inn Building 511 Tul..J 04/26102 Prepared by: Neir & Associates, Inc. 08 :31 AM #1111 - Studio A 1. General Details: Floor Area 515.0 ft Avg. Ceiling Height 8.000 ft Building Weight 70.000 Ib/ft 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 3 People Wattage 200.0 Watts Activity Level Seated at Rest Ballast Multiplier 1.08 Sensible 230.0 BTU/hr/person Schedule Typical Occupancy Latent 120.0 BTU/hr /person Schedule Typical Occupancy 2.2. Task Lighting: Wattage 0 00 W/ft' Schedule None 2.3. Electrical Equipment: Wattage 0 00 W/R' Schedule None 3. Walls, Windows, Doors: 3.1. Construction Types for Exposure N Wall Type Wood Siding + Sheathing + R -21 Batt 3.2. Construction Types for Exposure W Wall Type Wood Siding + Sheathing + R -21 Batt 3.3. Construction Types for Exposure E Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 3.4. Construction Types for Exposure S Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Door Type Typical Door 4. Roofs, Skylights: Exp. H Roof Gross Area (f') 515.0 Roof Slope (deg.) 0 Skylight Qty. 0 4.1. Construction Types for Exposure H Roof Type Cathedral + GWB + R -30 Batt 2.5. Miscellaneous Loads: Sensible 152 BTU/hr Schedule Typical Occupancy Latent 0 BTU/hr Schedule None 5. Infiltration: Design Cooling 0 50 CFM/ft' Design Heating 0 50 CFM/ft Energy Analysis 0 0 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Slab Floor On Grade Floor Area 515.0 ft Carrier Hourly Analysis Program v4.04 Page 1 Project Name: Residence Inn Building #11 Tu. Prepared by: Neir & Associates, Inc. Total Floor U -Value 0.100 BTUIhrM lF Exposed Perimeter 51.8 ft Edge Insulation R -Value 10.0 hr -ft -F/BTU 7. Partitions: (No partition data). Space Input Data 04/26102 08:31 AM Carrier Hourly Analysis Program v4.04 Page 2 Exp. Wall Gross Area (ft Window 1 Qty. Window 2 Qty. Door 1 Qty. E 168.0 10 0 1 S 192.0 40 0 0 s Project Name: Residence Inn Building 411 Tukwila Prepared by: Neir & Associates, Inc. #1112 - Studio B 1. General Details: Floor Area Avg. Ceiling Height Building Weight 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 3 People Wattage 200.0 Watts Activity Level Seated at Rest Ballast Multiplier 1.08 Sensible 230.0 BTU/hr /person Schedule Typical Occupancy Latent 120.0 BTU/hr /person Schedule Typical Occupancy 2.2. Task Lighting: Wattage 0 00 W/ft Schedule None 2.3. Electrical Equipment: Wattage 0.00 W/ft Schedule None 3. Walls, Windows, Doors: 3.1. Construction Types for Exposure E Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Door Type Typical Door 3.2. Construction Types for Exposure S Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 4. Roofs, Skylights: 7. Partitions: (No partition data). 492 0 ft 8.000 ft 70.000 Ib/ t Exp. H Roof Gross Area (ft 492.0 Roof Slope (deg.) 0 Skylight Qty. 0 4.1. Construction Types for Exposure H Roof Type Cathedral + GWB + R-30 Batt 5. Infiltration: Design Cooling 0.50 CFM/ft Design Heating 0 50 CFM/ft Energy Analysis 0 0 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Slab Floor On Grade Floor Area 492.0 ft Total Floor U -Value 0.100 BTU/hr/ft Exposed Perimeter 51 5 ft Edge Insulation R -Value 10 0 hr- ft -FIBTU Carrier Hourly Analysis Program v4.04 Space Input Data _J 2.5. Miscellaneous Loads: Sensible 152 BTU/hr Schedule Typical Occupancy Latent 0 BTU/hr Schedule None - 04/26/02 08:26 AM Page 1 Exp. Wall Gross Area (ft Window 1 Qty. Window 2 Qty. Door 1 Qty. S 168.0 0 0 0 E 40.0 0 0 0 W 208.0 50 0 0 N 76.0 0 0 1 Project Name: Residence Inn Building #11 Tu. Prepared by: Neir & Associates, Inc. #1113 - Studio A 1. General Details: Floor Area 515.0 ft Avg. Ceiling Height 8 000 if Building Weight 70.000 lb/ft 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 3 People Wattage 200.0 Watts Activity Level Seated at Rest Ballast Multiplier 1.08 Sensible 230.0 BTU/hr /person Schedule Typical Occupancy Latent 120.0 BTU/hr /person Schedule Typical Occupancy 2.2. Task Lighting: Wattage 0.00 WAN Schedule None 2.3. Electrical Equipment: Wattage 0.00 WAN Schedule None 3. Walls, Windows, Doors: 3.1. Construction Types for Exposure S Wall Type Wood Siding + Sheathing + R -21 Batt 3.2. Construction Types for Exposure E Wall Type Wood Siding + Sheathing + R -21 Batt 3.3. Construction Types for Exposure W Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 3.4. Construction Types for Exposure N Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Door Type Typical Door 4. Roofs, Skylights: Exp. H Roof Gross Area (1N) 515.0 Roof Slope (deg.) 0 Skylight Qty. 0 4.1. Construction Types for Exposure H Roof Type Cathedral + GWB + R -30 Batt 5. Infiltration: Design Cooling 0 50 CFMAN Design Heating 0 50 CFM/ft Energy Analysis 0 0 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Slab Floor On Grade Floor Area 515 0 ft Carrier Hourly Analysis Program v4.04 Space Input Data 2.5. Miscellaneous Loads: Sensible 152 BTU/hr Schedule Typical Occupancy Latent 0 BTU/hr Schedule None 04/26102 08:32 AM Page 1 Project Name: Residence Inn Building 011 Tukwila Prepared by: Neir & Associates, Inc. Total Floor U -Value 0.100 BTU/hr/tt'/F Exposed Perimeter 51.5 ft Edge Insulation R-Value 10.0 hr- R: -FBTU 7. Partitions: (No partition data). Space Input Data • 0426102 08:32 AM Carrier Hourly Analysis Program v4.04 Page 2 Exp. Wall Gross Area (ft') Window 1 Qty. Window 2 Qty. Door 1 Qty. W 168.0 10 0 1 N 192.0 40 0 0 r, - Project Name: Residence Inn Building 011 Tukb.... Prepared by: Neir & Associates, Inc. #1114 - Studio B 1. General Details: Floor Area 492.0 ft' Avg. Ceiling Height 8.000 ft Building Weight 70.000 IbM 2. internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule Free Hanging 200.0 Watts 1.08 Typical Occupancy 2.2. Task Lighting: Wattage 0.00 W/ft' Schedule None 2.3. Electrical Equipment: Wattage 0.00 W/ft Schedule None 3. Wails. Windows, Doors: Space Input Data 2.4. People: Occupancy 3 People Activity Level Seated at Rest Sensible 230.0 BTU/hr /person Latent 120.0 BTU/hr/person Schedule Typical Occupancy 2.5. Miscellaneous Loads: Sensible 152 BTU/hr Schedule Typical Occupancy Latent 0 BTU/hr Schedule None 3.1. Construction Types for Exposure W Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Door Type Typical Door 3.2. Construction Types for Exposure N Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 4. Roofs, Skylights: Exp. H Roof Gross Area (ft') 492.0 Roof Slope (deg.) 0 Skylight Qty. 0 4.1. Construction Types for Exposure H Roof Type Cathedral + GWB + R-30 Batt 5. Infiltration: Design Cooling 0 50 CFM/ft' Design Heating 0 50 CFM/ft Energy Analysis 0.0 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Slab Floor On Grade Floor Area 492.0 fl= Total Floor U Value 0100 BTU/hr/ft Exposed Perimeter 51 5 ft Edge Insulation R -Value 10.0 hr -ft -F/BTU 7. Partitions: (No partition data). 04Q6/02 08:33 AM Carrier Hourly Analysis Program v4.04 Page 1 Exp. Wall Gross Area (ft Window 1 Qty. Window 2 Qty. Door 1 Qty. N 168.0 0 0 0 W 40.0 0 0 0 E 208.0 50 0 0 S 76.0 0 0 1 ri Project Name: Residence Inn Building #11 Tur. ! 04/26/02 Prepared by: Neir & Associates, Inc. 08:33 AM #1121 - Studio A 1. General Details: Floor Area Avg. Ceiling Height Building Weight 515.0 ft 8.000 ft 70.000 lb/ft 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 3 People Wattage 200 0 Watts Activity Level Seated at Rest Ballast Multiplier 1.08 Sensible 230.0 BTU/hr /person Schedule Typical Occupancy Latent 120.0 BTU/hr /person Schedule Typical Occupancy 2.2. Task Lighting: Wattage 0.00 Witt' Schedule None 2.3. Electrical Equipment: Wattage 0.00 W/ft' Schedule None 3. Walls, Windows, Doors: Space Input Data 2.5. Miscellaneous Loads: Sensible 152 BTU/hr Schedule Typical Occupancy Latent 0 BTU/hr Schedule None 3.1. Construction Types for Exposure N Wail Type Wood Siding + Sheathing + R -21 Batt 3.2. Construction Types for Exposure W Wall Type Wood Siding + Sheathing + R -21 Batt 3.3. Construction Types for Exposure E Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 3.4. Construction Types for Exposure S Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Door Type Typical Door 4. Roofs, Skylights: Exp. H Roof Gross Area (fN) 515.0 Roof Slope (deg.) 0 Skylight Qty. 0 4.1. Construction Types for Exposure H Roof Type TrusslFlat + GWB + R-30 Batt 5. Infiltration: Design Cooling 0.50 CFM/ft Design Heating 0 50 CFM/ft' Energy Analysis 0 0 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). Carrier Hourly Analysis Program v4.04 Page 1 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. Exp. Wall Gross Area MI Window 1 Qty. Window 2 Qty. Door 1 Qty. E 204.0 10 0 1 S 204.0 24 0 0 Project Name: Residence Inn Building #11 Prepared by: Neir & Associates, Inc. #1122 Main 1. General Details: Floor Area 522 0 ft: Avg. Ceiling Height 9.500 ft Building Weight 70.000 Ib/ft 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 3 People Wattage 200.0 Watts Activity Level Seated at Rest Ballast Multiplier 1.08 Sensible 230.0 BTU/hr /person Schedule Typical Occupancy Latent 120.0 BTU/hr /person Schedule Typical Occupancy 2.2. Task Lighting: Wattage 0.00 W/ft Schedule None 2.3. Electrical Equipment: Wattage 0.00 W/ft Schedule None 3. Walls, Windows, Doors: Space Input Data 3.1. Construction Types for Exposure E Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Door Type Typical Door 3.2. Construction Types for Exposure S Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 4. Roofs, Skylights: Exp. E Roof Gross Area (ftl 315.0 Roof Slope (deg.) 35 Skylight Qty. 0 4.1. Construction Types for Exposure E Roof Type Cathedral + GWB + R-30 Batt 5. Infiltration: Design Cooling 0.50 CFM/ft' Design Heating 0 50 CFM/R Energy Analysis 0 0 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). 2.5. Miscellaneous Loads: Sensible 180 BTU/hr Schedule Typical Occupancy Latent 0 BTU/hr Schedule None 04/'26/02 '08:41 AM Carrier Hourly Analysis Program v4.04 Page 1 Exp. Wall Gross Area (ft Window 1 Qty. Window 2 Qty. Door 1 Qty. E 30.0 0 0 0 S 162.0 24 0 0 Project Name: Residence Inn Building #11 Tukw. Prepared by: Neir & Associates, Inc. #1122 Loft 1. General Details: Floor Area Avg. Ceiling Height Building Weight 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 2 People Wattage 100.0 Watts Activity Level Seated at Rest Ballast Multiplier 1 08 Sensible 230.0 BTU/hr /person Schedule Typical Occupancy Latent 120.0 BTU/hr /person Schedule Typical Occupancy 2.2. Task Lighting: Wattage 0.00 Wlft Schedule None 2.3. Electrical Equipment: Wattage 0 00 W/ft Schedule None 3. Walls, Windows, Doors: 288.0 ft 3.000 ft 70.000 IbNt 3.1. Construction Types for Exposure E Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 2nd Window Type Typical Window 3.2. Construction Types for Exposure S Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 4. Roofs, Skylights: Exp. H Roof Gross Area (111 312.0 Root Slope (deg.) 0 Skylight Qty. 0 4.1. Construction Types for Exposure H Roof Type Truss /Flat + GWB + R-30 Batt 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs only when the fan 0.50 CFM/ft 0 50 CFM/ft 0 0 CFM is off. Space Input Data 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None 0426/02 08:42 AM Carrier Hourly Analysis Program v4.04 Page 1 '11 ` W D p: O N ` F_ . W W IL l .. z. U N: O Z • 1 Exp. Wall Gross Area (In Window 1 Qty. Window 2 Qty. Door 1 Qty. S 168.0 0 0 0 E 40.0 0 0 0 W 208.0 50 0 0 N 76.0 0 0 1 ;ii Project Name: Residence Inn Building #11 Tukwila Prepared by: Neir & Associates, Inc. #1123 - Studio A l 'alemamaisT 1. General Details: Floor Area 515.0 ft Avg. Ceiling Height 8.000 ft Building Weight 70.000 Ib/ft' 2. Internals: 2.1. Overhead Lighting: Fixture Type Free Hanging Wattage 200.0 Watts Ballast Multiplier 1.08 Schedule Typical Occupancy 2.2. Task Lighting: Wattage 0.00 W/ft Schedule None 2.3. Electrical Equipment: Wattage 0.00 W/lN Schedule None 3. Walls, Windows, Doors: Space Input Data 3.1. Construction Types for Exposure S Wall Type Wood Siding + Sheathing + R -21 Batt 3.2. Construction Types for Exposure E Wall Type Wood Siding + Sheathing + R -21 Batt 3.3. Construction Types for Exposure W Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 3.4. Construction Types for Exposure N Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Door Type Typical Door 4. Roots, Skylights: Exp. H Roof Gross Area (1t') 515.0 Roof Slope (deg.) 0 Skylight Qty. 0 4.1. Construction Types for Exposure H Roof Type Truss/Flat + GWB + R -30 Batt 5. Infiltration: Design Cooling 0 50 CFM/ft Design Heating 0 50 CFM/ft Energy Analysis 0 0 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). Carrier Hourly Analysis Program v4.04 6 2.4. People: Occupancy 3 People Activity Level Seated at Rest Sensible 230.0 BTU/hr /person Latent 120.0 BTU/hr /person Schedule Typical Occupancy 2.5. Miscellaneous Loads: Sensible 152 BTU/hr Schedule Typical Occupancy Latent 0 BTU/hr Schedule None 0426102 08:41 AM Page 1 •s1.�a:re:mn nmc - tssa:.�.•. - r! Srti�E. cw <F;:'+�.ucrcc.4�:z»• �:�: -«z:.: _•.. t��..�a.n.:x� o.- _,.. ,. NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. V Z = O o a A r m C a • Exp. Wall Gross Area (ftq Window 1 Qty. Window 2 Qty. Door 1 Qty. W 204.0 10 0 1 N 204.0 24 0 0 •1 Project Name: Residence Inn Building 811 Tukwila Prepared by: Neir & Associates, Inc. 81124 Main 1. General Details: Floor Area 822.0 ft' Avg. Ceiling Height 9.500 ft Building Weight 70.000 Ib/it 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule Free Hanging 200.0 Watts 1 08 Typical Occupancy 2.2. Task Lighting: Wattage 0 00 W/ft Schedule None 2.3. Electrical Equipment: Wattage 0.00 W/ft Schedule None 3. Walls, Windows, Doors: 3.1. Construction Types for Exposure W Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Door Type Typical Door 3.2. Construction Types for Exposure N Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 4. Roofs, Skylights: Exp. W Roof Gross Area (ft') 315.0 Roof Slope (deg.) 35 Skylight Qty. 0 4.1. Construction Types for Exposure W Roof Type Cathedral + GWB + R -30 Batt 5. Infiltration: Design Cooling 0.50 CFM/ft Design Heating 0 50 CFM/ft Energy Analysis 0 0 CFM Infiltration occurs only when the fan is off. 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Space Input Data 2.4. People: Occupancy 3 People Activity Level Seated at Rest Sensible 230.0 BTU/hr /person Latent 120.0 BTU/hr /person Schedule Typical Occupancy 2.5. Miscellaneous Loads: Sensible 180 BTU/hr Schedule Typical Occupancy Latent 0 BTU/hr Schedule None 04/26/02 08:42 AM Carrier Hourly Analysis Program v4.04 Page 1 Exp. Wall Gross Area (ft') Window 1 Qty. Window 2 Qty. Door 1 Qty. W 30.0 0 0 0 N 162.0 24 0 0 a; Project Name: Residence Inn Building #11 TL. ..a Prepared by: Neir & Associates, Inc. #1124 Loft 1. General Details: Floor Area Avg. Ceiling Height Building Weight 2.2. Task Lighting: Wattage 0.00 W/tt Schedule None 2.3. Electrical Equipment: Wattage 0.00 W/f1 Schedule None 3. Wails, Windows, Doors: 4. Roofs, Skylights: 288.0 ft 8.000 ft 70.000 lb/ft 4.1. Construction Types for Exposure H Roof Type Truss /Flat + GWB + R-30 Batt 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs only when the fan 7. Partitions: (No partition data). Carrier Hourly Analysis Program v4.04 0.50 CFM/ft 0 50 CFM/ft 0 0 CFM is off. Space Input Data 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Free Hanging Occupancy 2 People Wattage 100.0 Watts Activity Level Seated at Rest Ballast Multiplier 1.08 Sensible 230.0 BTU/hr /person Schedule Typical Occupancy Latent 120.0 BTU/hr /person Schedule Typical Occupancy 3.1. Construction Types for Exposure W Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window 2nd Window Type Typical Window 3.2. Construction Types for Exposure N Wall Type Wood Siding + Sheathing + R -21 Batt 1st Window Type Typical Window Exp. H Roof Gross Area (ft 312.0 Roof Slope (deg.) 0 Skylight Qty. 0 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None 04/26102 08 :42 AM Page 1 Project Name: Residence Inn Building 111 Tuk..ua Prepared by: Neir & Associates, Inc. 1. General Details: Air System Name #1111 System Equipment Class Split AHU Air System Type Single Zone CAV Number of zones 1 6 -System Input Report - #1111 Syc –m _J 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Design Airflow 20 00 CFM /person Unocc. Damper Position Closed Damper Leak Rate 5 % Central Cooling Data: Supply Air Temperature 55 0 °F Coil Bypass Factor 0 100 Cooling Source DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Central Heating Data: Supply Temperature 110.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw -thru Fan Performance 0.00 in. wg. Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 #1111 - Studio A x1 Thermostats and Zone Data: Zone _All Cooling T -stat: Occ. 75 0 °F Cooling T -stat: Unocc. 85 0 °F Heating T -stat: Occ. 70 0 °F Heating T -stat: Unocc. 60 0 °F T -stat Throttling Range 3 00 °F Diversity Factor 100 % Direct Exhaust Airflow 0 0 CFM Direct Exhaust Fan kW 0 0 kW 0426/02 08:55 AM Thermostat Schedule Typical Thermostat Unoccupied Cooling is _Available Carrier Hourly Analysis Program v4.04 Page 1 Zone Supply Airflow (CFM) Zone Htg Unit (BTU /hr) Reheat Coil (BTU /hr) FPMBX Fan (CFM) 1 258.7 - - - ii t Air - System Input Report - #1111 System Project Name: Residence Inn Building 011 Tuk:. . ' _ 04/26/02 Prepared by: Neir & Associates, Inc. 08:55 AM Supply Terminals Data Zone All Terminal Type Diffuser Minimum Airflow 0 00 CFM /person Zone Heating Units Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer- Generated) System Sizing Data: Cooling Supply Temperature 55 0 °F Supply Fan Airflow 258 7 CFM Ventilation Airflow 60 0 CFM Heating Supply Temperature 110.0 °F Hydronic Sizing Specifications Chilled Water Delta -T 10 0 °F Hot Water Delta -T 20 0 °F Safety Factors Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads Carrier Hourly Analysis Program v4.04 Page 2 t e. Ar Input Report - #1112 Sys'' - n Project Name: Residence Inn Building 011 Tukwila - 0426102 Prepared by: Neir & Associates, Inc. 08:55 AM 1. General Details: Air System Name #1112 System Equipment Class Split AHU Air System Type Single Zone CAV Number of zones 1 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Design Airflow 20 00 CFM /person Unocc. Damper Position Closed Damper Leak Rate 5 % Central Cooling Data: Supply Air Temperature 55 0 °F Coil Bypass Factor 0 100 Cooling Source DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Central Heating Data: Supply Temperature 110.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw -thru Fan Performance 0 00 in. wg. Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 #1112 - Studio B x1 Thermostats and Zone Data: Zone Ali Cooling T -stat: Occ. 75 0 °F Cooling T -stat: Unocc. 85 0 °F Heating T -stat: Occ. 70 0 °F Heating T -stat: Unocc. 60 0 °F T -stat Throttling Range 3 00 °F Diversity Factor 100 % Direct Exhaust Airflow 0 0 CFM Direct Exhaust Fan kW 0 0 kW Thermostat Schedule Typical Thermostat Unoccupied Cooling is Available Carrier Hourly Analysis Program v4.04 Page 1 Zone Supply Airflow (CFM) Zone Htg Unit (BTU /hr) Reheat Coil (BTU /hr) FPMBX Fan (CFM) 1 281.4 - - - 3t • to -- System Input Report - #1112 Sys` -m Project Name: Residence Inn Building 011 Tuk....a 0426/02 Prepared by: Weir & Associates, Inc. 08:55 AM Supply Terminals Data Zone All Terminal Type Diffuser Minimum Airflow 0.00 CFM /person Zone Heating Units Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer- Generated) System Sizing Data: Cooling Supply Temperature 55 0 °F Supply Fan Airflow 281.4 CFM Ventilation Airflow 60 0 CFM Heating Supply Temperature 110.0 °F Hydronic Sizing Specifications Chilled Water Delta -T 10 0 °F Hot Water Delta -T 20 0 °F Safety Factors Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads Carrier Hourly Analysis Program v4.04 Page 2 Project Name: Residence Inn Building #11 Tukwila Prepared by: Neir & Associates, Inc. 1. General Details: Air System Name Equipment Class Air System Type Number of zones F''1System Input Report - #1113 Syr'm _J 01113 System Split AHU Single Zone CAV 1 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Design Airflow 20 00 CFM /person Unocc. Damper Position Closed Damper Leak Rate 5 % Central Cooling Data: Supply Air Temperature 55 0 °F Coil Bypass Factor 0 100 Cooling Source DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Central Heating Data: Supply Temperature 110.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw-thru Fan Performance 0.00 in. wg. Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 #1113 - Studio A x1 Thermostats and Zone Data: Zone All Cooling T -stat: Occ. 75 0 °F Cooling T -stat: Unocc. 85 0 °F Heating T -stat: Occ. 70 0 °F Heating T -stat: Unocc. 60 0 °F T -stat Throttling Range 3 00 °F Diversity Factor 100 % Direct Exhaust Airflow 0 0 CFM Direct Exhaust Fan kW 0 0 kW Thermostat Schedule Typical Thermostat Unoccupied Cooling is Available 04/26/02 08:55 AM Carrier Hourly Analysis Program v4.04 Page 1 Zone Supply Airflow (CFM) Zone Htg Unit (BTU /hr) Reheat Coil (BTU /hr) FPMBX Fan (CFM) 1 312.9 - - - AIr..System Input Report - #1113 Sys +gym Project Name: Residence Inn Building 011 Tula Prepared by: Neir & Associates, Inc. Supply Terminals Data Zone All Terminal Type Diffuser Minimum Airflow 0 00 CFM /person Zone Heating Units Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer - Generated) System Sizing Data: Cooling Supply Temperature Supply Fan Airflow Ventilation Airflow Heating Supply Temperature Hydronic Sizing Specifications Chilled Water Delta -T Hot Water Delta -T Safety Factors Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % 550 °F 312.9 CFM 60 0 CFM 110.0 °F 10 0 °F 200 °F Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads 04/26/02 08:55 AM Carrier Hourly Analysis Program v4.04 Page 2 . ( Air-System Input Report - #1114 System Project Name: Residence Inn Building 011 Tuk Prepared by: Neir & Associates, Inc. 1. General Details: Air System Name Equipment Class Air System Type Number of zones 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Design Airflow 20.00 CFM /person Unocc. Damper Position Closed Damper Leak Rate 5 % Central Cooling Data: Supply Air Temperature 55 0 °F Coil Bypass Factor 0 100 Cooling Source DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Central Heating Data: Supply Temperature Heating Source Schedule Capacity Control Carrier Hourly Analysis Program v4.04 #1114 System Split AHU Single Zone CAV 1 110.0 °F Electric Resistance JFMAMJJASOND Cycled or Staged Compressor - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw -thru Fan Performance 0 00 in. wg. Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 #1114 - Studio B x1 Thermostats and Zone Data: Zone All Cooling T -stat: Occ. 75 0 °F Cooling T -stat: Unocc. 85 0 °F Heating T -stat: Occ. 70 0 °F Heating T -stat: Unocc. 60 0 °F T -stat Throttling Range 3 00 °F Diversity Factor 100 % Direct Exhaust Airflow 0 0 CFM Direct Exhaust Fan kW 0 0 kW Thermostat Schedule Typical Thermostat Unoccupied Cooling is Available 04/26/02 08:56 AM Page 1 Zone Supply Airflow (CFM) Zone Htg Unit (BTU /hr) Reheat Coil (BTU /hr) FPMBX Fan (CFM) 1 205.0 - - - k -System Input Report - #1114 Sys'"T Project Name: Residence Inn Building 011 Tukwila 0426/02 Prepared by: Neir & Associates, Inc. 08:56 AM Supply Terminals Data Zone ___All Terminal Type Diffuser Minimum Airflow 0 00 CFM /person Zone Heating Units Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer- Generated) System Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 205.0 CFM Ventilation Airflow 60 0 CFM Heating Supply Temperature 110.0 °F Hydronic Sizing Specifications Chilled Water Delta -T 10 0 °F Hot Water Delta -T 20.0 °F Safety Factors Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads Carrier Hourly Analysis Program v4.04 Page 2 • Project Name: Residence Inn Building 011 Tuk....d 0426/02 Prepared by: Neir & Associates, Inc. 09:11 AM 1. General Details: Air System Name Equipment Class Air System Type Number of. zones A ;-System Input Report - #1121 Sys` --m #1121 System Split AHU Single Zone CAV 1 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Design Airflow 20 00 CFM /person Unocc. Damper Position Closed Damper Leak Rate 5 % Central Cooling Data: Supply Air Temperature 55 0 °F Coil Bypass Factor 0 100 Cooling Source DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Central Heating Data: Supply Temperature 110.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw -thru Fan Performance 0 00 in. wg. Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 #1121 - Studio A x1 Thermostats and Zone Data: Zone Cooling T -stat: Occ. 75.0 °F Cooling T -stat: Unocc. 85 0 °F Heating T -stat: Occ. 70 0 °F Heating T -stat: Unocc. 60 0 °F T -stat Throttling Range 3 00 °F Diversity Factor 100 % Direct Exhaust Airflow 0 0 CFM Direct Exhaust Fan kW 0 0 kW Thermostat Schedule Typical Thermostat Unoccupied Cooling is Available Carrier Hourly Analysis Program v4.04 Page 1 Zone Supply Airflow (CFM) Zone Htg Unit (BTU /hr) Reheat Coil (BTU /hr) FPMBX Fan (CFM) 1 251.5 - - - ti • N.- System Input Report - #1121 Sys + °m _J Project Name: Residence Inn Building #11 Tukk.. 0426/02 Prepared by: Neir & Associates, Inc. 09:11 AM Supply Terminals Data Zone _All Terminal Type Diffuser Minimum Airflow 0 00 CFM /person Zone Heating Units Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer- Generated) System Sizing Data: Cooling Supply Temperature 55 0 °F Supply Fan Airflow 251.5 CFM Ventilation Airflow 60 0 CFM Heating Supply Temperature 110.0 °F Hydronic Sizing Specifications Chilled Water Delta -T 10 0 °F Hot Water Delta -T 20.0 °F Safety Factors Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads Carrier Hourly Analysis Program v4.04 Page 2 Project Name: Residence Inn Building #11 Tukviiiia Prepared by: Neir & Associates, Inc. 1. General Details: Air System Name Equipment Class Air System Type Number of zones D- 'System Input Report - #1122 Sye "m 01122 System Split AHU Single Zone CAV 1 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Design Airflow 20 00 CFM /person Unocc. Damper Position Closed Damper Leak Rate 5 % Central Cooling Data: Supply Air Temperature 55 0 °F Coil Bypass Factor 0 100 Cooling Source DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Central Heating Data: Supply Temperature 110.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw -thru Fan Performance 0 00 in. wg. Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 #1122 Main Thermostats and Zone Data: Zone Cooling T -stat: Occ. Cooling T -stat: Unocc. Heating T -stat: Occ. Heating T -stat: Unocc. T -stat Throttling Range Diversity Factor Direct Exhaust Airflow Direct Exhaust Fan kW x 1 All 75 0 °F 85 0 °F 70 0 °F #1122 Loft x1 04/26/02 09:12 AM 60 0 °F 300 °F 100 % 0 0 CFM 0 0 kW Thermostat Schedule Typical Thermostat Unoccupied Cooling is Available Carrier Hourly Analysis Program v4.04 Page 1 Zone Supply Airflow (CFM) Zone Htg Unit (BTU /hr) Reheat Coil (BTU /hr) FPMBX Fan (CFM) 1 373.3 - - - Ak,System Input Report - #1122 System Project Name: Residence Inn Building #11 Tu,... 04/26102 Prepared by: Neir & Associates, Inc. 09 :12 AM Supply Terminals Data Zone All Terminal Type Diffuser Minimum Airflow 0 00 CFM /person Zone Heating Units Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer- Generated) System Sizing Data: Cooling Supply Temperature 55 0 °F Supply Fan Airflow 373.3 CFM Ventilation Airflow 100.0 CFM Heating Supply Temperature 110.0 °F Hydronic Sizing Specifications Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads Carrier Hourly Analysis Program v4.04 Page 2 Project Name: Residence Inn Building #11 Tu. Prepared by: Neir & Associates, Inc. 2. System Components: Ventilation Air Data: Airflow Control Design Airflow Unocc. Damper Position Damper Leak Rate Carrier Hourly Analysis Program v4.04 1. General Details: Air System Name #1123 System Equipment Class Split AHU Air System Type Single Zone CAV Number of zones 1 Constant Ventilation Airflow 20 00 CFM /person Closed 5% Central Cooling Data: Supply Air Temperature 55 0 °F Coil Bypass Factor 0 100 Cooling Source DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Central Heating Data: Supply Temperature 110.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw-thru Fan Performance 0 00 in. wg. Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 #1123 - Studio A x1 Thermostats and Zone Data: Zone _All Cooling T -stat: Occ. 75 0 °F Cooling T -stat: Unocc. 85 0 °F Heating T -stat: Occ. 70 0 °F Heating T -stat: Unocc. 60 0 °F T -stat Throttling Range 3 00 °F Diversity Factor 100 % Direct Exhaust Airflow 0 0 CFM Direct Exhaust Fan kW 0 0 kW Air,System Input Report - #1123 Sysl m Thermostat Schedule Typical Thermostat Unoccupied Cooling is _Available 04/26102 09:12 AM Page 1 Zone Supply Airflow (CFM) Zone Htq Unit (BTU /hr) Reheat Coil (BTU /hr) FPMBX Fan (CFM) 1 312.9 - - - A;--System Input Report - #1123 Sysfr m Project Name: Residence Inn Building 011 Tuko...a 0426/02 Prepared by: Neir & Associates, Inc. 09:12 AM Supply Terminals Data Zone All Terminal Type Diffuser Minimum Airflow 0 00 CFM /person Zone Heating Units Zone All Zone Heating Unit Type None Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer - Generated) System Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 312 9 CFM Ventilation Airflow 60.0 CFM Heating Supply Temperature 110.0 °F Hydronic Sizing Specifications Chilled Water Delta -T 10 0 °F Hot Water Delta -T 20.0 °F Safety Factors Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method Coincident space loads Peak zone sensible load Carrier Hourly Analysis Program v4.04 Page 2 Ak System Input Report - #1124 System I Project Name: Residence Inn Building #11 TL. 0426/02 Prepared by: Neir & Associates, Inc. 09:13 AM 1. General Details: Air System Name #1124 System Equipment Class Split AHU Air System Type Single Zone CAV Number of zones 1 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Design Airflow 20 00 CFM /person Unocc. Damper Position Closed Damper Leak Rate 5 % Central Cooling Data: Supply Air Temperature 55 0 °F Coil Bypass Factor 0 100 Cooling Source DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Central Heating Data: Supply Temperature 110.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Compressor - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw -thru Fan Performance 0 00 in. wg. Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain 0 % Duct Leakage 0 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 #1124 Main x1 Thermostats and Zone Data: Zone All Cooling T -stat: Occ. 75 0 °F Cooling T -stat: Unocc. 85 0 °F Heating T -stat: Occ. 70 0 °F Heating T -stat: Unocc. 60 0 °F T -stat Throttling Range 3 00 °F Diversity Factor 100 % Direct Exhaust Airflow 0 0 CFM Direct Exhaust Fan kW 0 0 kW Thermostat Schedule Typical Thermostat Unoccupied Cooling is _ _Available Carrier Hourly Analysis Program v4.04 #1124 Loft x1 Page 1 Zone Supply Airflow (CFM) Zone Htg Unit (BTU /hr) Reheat Coil (BTU /hr) FPMBX Fan (CFM) 1 290.0 - - - Project Name: Residence Inn Building #11 Tukwila Prepared by: Neir & Associates, Inc. Supply Terminals Data Zone All Terminal Type Diffuser Minimum Airflow 0 00 CFM /person Zone Heating Units Zone All Zone Heating Unit Type None 4. Sizing Data (Computer- Generated) System Sizing Data: Cooling Supply Temperature 55 0 °F Supply Fan Airflow 290.0 CFM Ventilation Airflow 100.0 CFM Heating Supply Temperature 110.0 °F Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND Hydronic Sizing Specifications Chilled Water Delta -T 10 0 °F Hot Water Delta -T 20 0 °F Safety Factors Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Peak zone sensible load Space Airflow Sizing Method Coincident space loads t---,System Input Report - #1124 Syr" Carrier Hourly Analysis Program v4.04 Page 2 04!26/02 09:13 AM Project Name: Residence Inn Building #11 Ti. .a Prepared by: Nair & Associates, Inc. Air Sy,stem Sizing Summary for #1111 System Air System Information System Name #1111 System Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 515.0 ft' Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 0.4 Tons Load occurs at Jul 1600 Sensible coil load 0.4 Tons OA DB / WB 85 0165.0 °F Coil CFM at Jul 1600 259 CFM Entering DB / WB 78.9184.4 'F Max possible CFM 259 CFM Leaving DB / WB 60.8158.0 'F Design supply temp. 55 0 'F Coil ADP 58.8 °F ft 1243.4 Bypass factor 0100 BTU/hr/R' 9 7 Resulting RH 50 % Water flow @ 10.0 'F rise - gpm Zone T -stat Check 1 of 1 OK Central Heating Coil Sizing Data Max coil load 8898 BTU/hr Load occurs at Des Htg Coil CFM at Des Htg 259 CFM BTU/hr/R' 13.0 Max possible CFM 259 CFM Ent. DB / Lvg DB 58.4182.8 'F Water flow @ 20.0 °F drop - gpm Supply Fan Sizing Data Actual max CFM at Jun 1100 259 CFM Fan motor BHP 0 00 BHP Standard CFM 254 CFM Fan motor kW 0.00 kW Actual max CFM/ft 0.50 CFM/ft Fan static 0.00 in. wg. Outdoor Ventilation Air Data Design airflow CFM 80 CFM CFM /person 20.00 CFM /person CFM/ft' 012 CFM/ft' 04/26/02 08:53 AM Carrier Hourly Analysis Program v4.04 Page 1 're W 00 9 u) W u- N a 2 p 0 f- W W; . H 0. 9--O w z i ' ~O t" Z Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone 1 5.5 259 259 Jun 1100 4.0 Zone Name I Space Name Mutt Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH► Zone 1 #1111 - Studio A 1 5.5 Jun 1100 259 4.0 • I Zr'e Sizing Summary for #1111 Systr'm Project Name: Residence Inn Building #11 Tub.... Prepared by: Neir & Associates, Inc. Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizing Data Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system Saace Loads and Airflows Carrier Hourly Analysis Program v4.04 Page 2 04/26/02 08 :53 AM Project Name: Residence Inn Building #11 Tu. Prepared by Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 Air System Design Load Summary for #11 System 04/26/02 08:53 AM Page 3 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OADBIWB 55.0 °F165.0 °F HEATING DATA AT DES HTG HEATING OADBIWB 23.0 °F119.2 °F ZONE LOADS Details Sensible (BTUIhr) Latent ( BTUIhr) Details Sensible ( BTUIhr) Latent (BTUIhrj - Solar Loads 50 ft 2197 - 50 ft - Wall Transmission 421 ft 354 - 421 ft' 825 - Roof Transmission 515 ft 1016 - 515 ft 743 - Glass Transmission 50 ft' 175 - 50 ft 1222 - Skylight Transmission 0 If 0 - 0 ft' 0 - Door Transmission 21 ft' 85 - 21 ft 592 - Floor Transmission 515 ft 0 - 515 ft 635 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 216 W 737 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 690 360 0 0 0 Infiltration - 0 0 0 0 0 Miscellaneous - 152 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5405 360 - 4016 0 Zone Conditioning - 4466 360 - 3757 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 Return Fan Load 259 CFM 0 - 259 CF 0 - Ventilation Load 60 CFM 504 -360 60 CF 2941 0 Supply Fan Load 259 CFM - 0 0 - - 259 CF - 0 0 - - Space Fan Coil Fans Duct Heat Gain / Loss 0% 0 - 0% 0 » Total System Loads - 4970 0 - 6698 0 Central Cooling Coil - 4970 0 - 0 0 Central Heating Coil - 0 - - 6698 - » Total Conditioning - 4970 0 - 6698 0 Key: Positive values are clg Negative values are htg loads loads Positive values are htg loads Negative values are cig loads Project Name: Residence Inn Building #11 Tu. Prepared by Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 Air System Design Load Summary for #11 System 04/26/02 08:53 AM Page 3 i Project Name: Residence Inn Building 011 Ti. I Prepared by: Nair & Associates, Inc. Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Air System Sizing Summary for #1112 Sys,m Air System Information System Name 01112 System Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 492 0 ft Central Cooling Coil Sizing Data Total coil load 0.5 Tons Sensible coil load 0 5 Tons Coil CFM at Sep 1500 289 CFM Max possible CFM 289 CFM Design supply temp. 55.0 °F ft 1088.7 BTU/hr/f 11 0 Water flow 7, 10.0 °F rise - gpm Load occurs at Sep 1500 OADB /WB 825183.8 °F Entering DB /WB 78.2163.9 °F Leaving DB /WB 80.5157.6 °F Coil ADP 58.8 °F Bypass factor 0.100 Resulting RH 49 % Zone T -stat Check 1 of 1 OK 04/26/02 09:14 AM Central Heating Coil Sizing Data Max coil load 8318 BTU/hr Load occurs at Des Htg Coil CFM at Des Htg 289 CFM BTU/hr/ft 12.8 Max possible CFM 289 CFM Ent. DB / Lvg DB 59.5180.1 °F Water flow @ 20.0 °F drop - gpm Supply Fan Sizing Data Actual max CFM at Sep 1500 289 CFM Fan motor BHP 0.00 BHP Standard CFM 284 CFM Fan motor kW 0.00 kW Actual max CFM/ft 0.59 CFM/ft Fart static 0.00 in. wg. Outdoor Ventilation Air Data Design airflow CFM 60 CFM CFM /person 20 00 CFM /person CFM/ft 0.12 CFM/ft Carrier Hourly Analysis Program v4.04 Page 1 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) 3.7 Zone 1 6.1 289 289 Sep 1500 Zone Name I Space Name Mutt Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Zone 1 #1112 - Studio B 1 6.1 Sep 1500 289 3.7 Project Name: Residence Inn Building #11 Tukwila Prepared by: Neir & Associates, Inc. Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizin4 Data Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system Space Loads and Airflows 7 Sizing Summary for #1112 Syr'° m Carrier Hourly Analysis Program v4.04 04r261o2 09:14 AM Page 2 Air Sysn Design Load Summary for #111- System Project Name: Residence Inn Building 011 Tu. .a Prepared by: Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 0426102 09:14 AM Page 3 DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1500 COOLING OA DB I WB 82.5 °F 1 83.8 °F HEATING DATA AT DES HTG HEATING OA DB I WB 23.0 °F 119.2 °F ZONE LOADS Details Sensible (BTUIhr) Latent ( BTUIhr) Details Sensible (BTUIhr) - Latent (BTUIhr) - Solar Loads 50 ft' 3367 - 50 ft' Wall Transmission 289 ft' 369 - 289 ft' 566 - Roof Transmission 492 ft' 657 - 492 ft' 710 - Glass Transmission 50 ft' 107 - 50 ft' 1222 - Skylight Transmission 0 ft' 0 - 0 ft 0 - Door Transmission 21 ft' 52 - 21 ft 592 - Floor Transmission 492 ft' 0 - 492 ft 617 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 216 W 737 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 690 360 0 0 0 Infiltration - 0 0 0 0 0 Miscellaneous - 152 0 - 0 0 Safety Factor 0% ! 0% 0 0 0% 0 0 » Total Zone Loads - 6131 360 - 3707 0 Zone Conditioning - 5094 360 - 3379 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 289 CFM 0 - 289 CFM 0 - Ventilation Load 60 CFM 339 -360 60 CFM 2939 0 Supply Fan Load 289 CFM 0 - 289 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5433 0 - 6318 0 Central Cooling Coil - 5433 0 - 0 0 Central Heating Coil - 0 - - 6318 - » Total Conditioning - 5433 0 - 6318 0 Key: Positive values are clg loads Negative values are htg loads Positive values are Mg loads Negative values are clg loads Air Sysn Design Load Summary for #111- System Project Name: Residence Inn Building 011 Tu. .a Prepared by: Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 0426102 09:14 AM Page 3 Air System Sizing Summary for #1113 Sustem Project Name: Residence Inn Building 011 TL i 04/26/02 Prepared by: Nair & Associates, Inc. 09:14 AM Air System Information System Name 11113 System Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 515.0 ft' Sizing Calculation Information Zone and Space Sizing Method: Z Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated fX a Central Cooling Coil Sizing Data a Total coil load 0.5 Tons Load occurs at Jul 1700 0 0 Sensible coil load 0.5 Tons OA DB / WB U.S / 64.8 °F CO W Coil CFM at Jul 1700 320 CFM Entering DB / WB 78.4164.3 °F Max possible CFM 320 CFM Leaving DB / WB 60.7158.1 °F H Design supply temp 55.0 °F Coil ADP 58.8 °F N LL ft 1028.5 Bypass factor 0.100 W O BTU/hr/ft 11.7 Resulting RH 50 % Water flow @ 10.0 °F rise - gpm Zone T -stat Check 1 of 1 OK J u_? Central Heating Coil Sizing Data W Max coil load 6688 BTU/hr Load occurs at Des Htg Z Coil CFM at Des Htg 320 CFM BTU/hr/ft 13.0 H 0 Max possible CFM 320 CFM Ent. DB / Lvg DB 60 5 /80.2 °F Z H Water flow @ 20.0 °F drop - gpm W W m p . Supply Fan Sizing Data 0 Ni Actual max CFM at Jun 1800 320 CFM Fan motor BHP 0.00 BHP 0 t Standard CFM 315 CFM Fan motor kW 0.00 kW W W Actual max CFM/fl' 0.82 CFM/ft= Fan static 0.00 in. wg. H ti- b Outdoor Ventilation Air Data W N Design airflow CFM 60 CFM CFM /person 20 00 CFM /person V CFM/ft 0.12 CFM/ft2 0 I — z Carrier Hourly Analysis Program v4.04 Page 1 1 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone 1 6.8 320 320 Jun 1800 4.0 Zone Name I Space Name Mutt Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Zone 1 #1113 - Studio A 1 6.8 Jun 1800 320 4.0 • Ze Sizing Summary for #1113 Sys!'n I Project Name: Residence Inn Building #11 Tuk..,,a 0426/02 Prepared by: Neir & Associates, Inc. 09:14 AM Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space loads Zone Sizing Data Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system Saace Loads and Airflows Calculation Months Sizing Data Calculated Jan to Dec Carrier Hourly Analysis Program v4.04 Page 2 { Project Name: Residence Inn Building #11 Tun...la Prepared by: Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 Air SKs *•' Design Load Summary for #11' — _System 0426/02 09:14 AM Page 3 • •' • DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB / WB 84.5 °F 184.8 °F HEATING DATA AT DES HTG HEATING OA DB 1 WB 23.0 °F 119.2 °F ZONE LOADS Details Sensible ( BTUIhr) Latent ( BTUIhr) Details Sensible ( BTUIhr) Latent (BTUIhr) Solar Loads 5011 3361 - 50 ft - - Wall Transmission 421 ft 548 - 421 ft 25 - Roof Transmission 515 ft 967 - 515 ft 743 - Glass Transmission 50 ft 171 - 50 ft 1222 - Skylight Transmission 0 ft 0 - 0 f1 0 - Door Transmission 21 ft 83 - 21 ft 592 - Floor Transmission 515 ft 0 - 515 ft 635 - Partitions 0 ft - 0 ft 0 - Ceiling 0 ft 0 - 0 ft 0 - Overhead Lighting 216 W 737 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 690 360 0 0 0 Infiltration - 0 0 0 0 0 Miscellaneous - 152 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6708 360 - 4018 0 Zone Conditioning - 5534 360 - 3742 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 320 CFM 0 - 320 CFM 0 - Ventilation Load 60 CFM 475 -360 60 CFM 2946 0 Supply Fan Load 320 CFM 0 - 320 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 6009 0 - 6688 0 Central Cooling Coil - 6009 0 - 0 0 Central Heating Coil - 0 - - 6688 - » Total Conditioning - 6009 0 - 6688 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Project Name: Residence Inn Building #11 Tun...la Prepared by: Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 Air SKs *•' Design Load Summary for #11' — _System 0426/02 09:14 AM Page 3 • •' • Project Name: Residence Inn Building #11 Tu.. Prepared by: Neir & Associates, Inc. Air System Information System Name 01114 System Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 492 0 ft' Sizing Calculation Information Z Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated re I Central Cooling Coil Sizing Data U O Total coil load 0 3 Tons Load occurs at Jul 1700 N 0 Sensible coil load 0 3 Tons OA DB / WB 84 5164.8 °F N w Coil CFM at Jul 1700 212 CFM Entering DB /WB 79.1 164.4 °F Max possible CFM 212 CFM Leaving DB / WB 61.0 / 58.0 °F N ii., Design supply temp. 55.0 °F Coil ADP 59.0 °F W 0 ft 1447.1 Bypass factor 0.100 2 BTU/hr/ft' 8 3 Resulting RH 50 % g Q : Water flow © 10.0 °F rise - gpm Zone T -stat Check 1 oil OK d . Central Heating Coil Sizing Data � Max coil load 6500 BTUIhr Load occurs at Des Htg Z I Coil CFM at Des Htg 212 CFM BTU/hr/ft 13.2 Z O Max possible CFM 212 CFM Ent. DB / Lvg DB 56.0 / 84.8 °F W W Water flow @ 20.0 °F drop - gpm M Supply Fan Sizing Data 0 I— Actual max CFM at Jun 1800 212 CFM Fan motor BHP 0.00 BHP W W Standard CFM 209 CFM Fan motor kW 0.00 kW 0 Actual max CFM/ft 043 CFM1f Fan static 0.00 in. cog. U. 0 Z '. Outdoor Ventilation Air Data U • Design airflow CFM 60 CFM CFM /person 20.00 CFM /person . O F CFM/ft 012 CFM/ft' Z Carrier Hourly Analysis Program v4.04 Air g <<stem Sizing Summary for #1114 ^''stem ° . ,.� .. �-•- -�- -- -- ..__.,.,.. ,,�� . -.,gym: 0426/02 09:15 AM Page 1 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone 1 4.5 212 212 Jun 1800 3.7 Zone Name / Space Name Muft Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Zone 1 #1114 - Studio B 1 4.5 Jun 1800 212 3.7 Za.cie Sizing Summary for #1114 Syr Project Name: Residence Inn Building *11 TL a Prepared by: Neir & Associates, Inc. Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Space CFM Zone Sizing Data Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system Space Loads and Airflows Peak zone sensible load Coincident space loads Calculation Months Jan to Dec Sizing Data Calculated Carrier Hourly Analysis Program v4.04 0426/02 09:15 AM Page 2 ij Project Name: Residence Inn Building #11 1.. .,da Prepared by: Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 Air Sy.tolm Design Load Summary for #1'' - 1 System 0426/02 - 09:15 AM Page 3 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB 1 WB 84.5 °F 184.8 °F HEATING DATA AT DES HTG HEATING OA DB 1 WB 23.0 °F 119.2 °F ZONE LOADS Details Sensible (BTUIhr) Latent (BTUIhr) Details Sensible (BTUIhr) - Latent (BTUIhr) - Solar Loads 50 ft 1379 - 50 ft Wall Transmission 289 ft 320 - 289 ft 566 - Roof Transmission 492 ft 924 - 492 ft 710 1222 - - Glass Transmission 50 ft 171 - 50 ft Skylight Transmission 0 ft 0 - 0 ft 0 - Door Transmission 21 ft 83 - 21 ft 592 - Floor Transmission 492 ft 0 - 492 ft 617 - Partitions 0 ft 0 - 0 ft 0 - Ceiling 0 ft 0 - 0 ft 0 - Overhead Lighting 216 W 737 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 690 360 0 0 0 Infiltration - 0 0 0 0 0 Miscellaneous - 152 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 4455 360 - 3707 0 Zone Conditioning - 3604 360 - 3564 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 212 CFM 0 - 212 CFM 0 - Ventilation Load 60 CFM 476 -360 60 CFM 2935 0 Supply Fan Load 212 CFM 0 - 212 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 4080 0 - 6500 0 Central Cooling Coil - 4080 0 - 0 0 Central Heating Coil - 0 - - 6500 - » Total Conditioning - 4080 0 - 6500 0 Key: Positive values are cig loads Negative values are htg loads Positive values are htg loads Negative values are cig loads ij Project Name: Residence Inn Building #11 1.. .,da Prepared by: Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 Air Sy.tolm Design Load Summary for #1'' - 1 System 0426/02 - 09:15 AM Page 3 ig Project Name: Residence Inn Building 011 Tuk....a Prepared by: Neir & Associates, Inc. Air °-'item Sizing Summary for #1121 ' item Air System Information System Name *1121 System Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 515.0 ft Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 0.4 Tons Load occurs at Jul 1600 Sensible coil load 0 4 Tons OA DB /WB 85.0165.0 °F Coil CFM at Jul 1600 259 CFM Entering DB /WB 78.9164.4 °F Max possible CFM 259 CFM Leaving DB /WB 60.8158.0 °F Design supply temp. 55.0 °F Coil ADP 58.8 °F ft 1243.4 Bypass factor 0.100 BTUIhr/ft 9 7 Resulting RH 50 % Water flow @ 10.0 °F rise - gpm Zone T -stat Check 1 of 1 OK Central Heating Coil Sizing Data Max coil load 5988 BTU/hr Load occurs at Des Htg Coil CFM at Des Htg 259 CFM BTU/hr/ft= 11.6 Max possible CFM 259 CFM Ent. DB / Lvg DB 58.5180.3 °F Water flow @ 20.0 °F drop - gpm Supply Fan Sizing Data Actual max CFM at Jun 1100 259 CFM Fan motor BHP 0.00 BHP Standard CFM 254 CFM Fan motor kW 0.00 kW Actual max CFM/ft 0.50 CFM/ft Fan static 0.00 in. wg. Outdoor Ventilation Air Data Design airflow CFM 60 CFM CFM /person 20 00 CFM /person CFM/ft' 012 CFM/ft Carrier Hourly Analysis Program v4.04 04/26/02 09:19 AM Page 1 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) 3.4 Zone 1 5.5 259 259 Jun 1100 Zone Name I Space Name Mutt Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Zone 1 #1121 - Studio A 1 5.5 Jun 1100 259 3.4 7--ne Sizing Summary for #1121 Syr' Project Name: Residence Inn Building #11 Tu,...11a 04/26102 Prepared by: Neir & Associates, Inc. 09:19 AM Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizing Data Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system Space Loads and Airflows Carrier Hourly Analysis Program v4.04 Page 2 Project Name: Residence Inn Building #11 Tu. ..a - Prepared by: Neir & Associates, Inc. Air Sy " m Design Load Summary for #11'`' S ystem 0426/02 09:19 AM Carrier Hourly Analysis Program v4.04 Page 3 "i DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB 1 WB 65.0 °F 1 65.0 °F HEATING DATA AT DES HTG HEATING OA DB I WB 23.0 °F 119.2 °F ZONE LOADS Details Sensible (BTUIhr) Latent (BTUIhr) Details Sensible (BTUIhr) Latent (BTUIhr) - Solar Loads 50 ft' 2197 - 50 ft Wall Transmission 421 ft 354 - 421 ft 825 - Roof Transmission 515 ft 1016 - 515 ft 743 - Glass Transmission 50 ft' 175 - 50 ft 1222 - Skylight Transmission 0 it' 0 - 0 ft' 0 - Door Transmission 21 ft' 85 - 21 ft' 592 - Floor Transmission 0 ft' 0 - 0 ft' 0 - Partitions Oft 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 216 W 737 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 690 360 0 0 0 Infiltration - 0 0 0 0 0 Miscellaneous - 152 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5405 360 - 3382 0 Zone Conditioning - 4466 360 - 3043 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 259 CFM 0 - 259 CFM 0 - Ventilation Load 60 CFM 504 -360 60 CFM 2945 0 Supply Fan Load 259 CFM 0 - 259 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 4970 0 - 5988 0 Central Cooling Coil - 4970 0 - 0 0 Central Heating Coil - 0 - - 5988 - » Total Conditioning - 4970 0 - 5988 0 Key: Positive values are clg loads Negative values are htq loads Positive values are htg loads Negative values are clg loads Project Name: Residence Inn Building #11 Tu. ..a - Prepared by: Neir & Associates, Inc. Air Sy " m Design Load Summary for #11'`' S ystem 0426/02 09:19 AM Carrier Hourly Analysis Program v4.04 Page 3 "i Project Name: Residence Inn Building 011 T. Prepared by: Neir & Associates, Inc. Air System Sizing Summary for #1122 °stem a Air System Information System Name *1122 System Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 810.0 ft' Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 0.6 Tons Load occurs at Sep 1500 Sensible coil load 0 6 Tons OA DB / WB 82.5 / 63.8 °F Coil CFM at Sep 1500 382 CFM Entering DB / WB 78 5163.9 °F Max possible CFM 382 CFM Leaving DB / WB 61.2157.7 °F Design supply temp. 55 0 °F Coil ADP 59 3 °F ft'/Ton 1387.9 Bypass factor 0 100 BTU/hr/ft 8 6 Resulting RH 49 % Water flow Q 10.0 °F rise - gpm Zone T -stat Check 1 of 1 OK Central Heating Coil Sizing Data Max coil load 8510 BTUihr Load occurs at Des Htg Coil CFM at Des Htg 382 CFM BTU/hr/ft 10 5 Max possible CFM 382 CFM Ent. DB / Lvg DB 57.2178.2 °F Water flow @ 20.0 °F drop - gpm Supply Fan Sizing Data Actual max CFM at Sep 1400 382 CFM Fan motor BHP 0.00 BHP Standard CFM 376 CFM Fan motor kW 0.00 kW Actual max CFM/ft' 0.47 CFM/ft Fan static 0 00 in. wg. Outdoor Ventilation Air Data Design airflow CFM 100 CFM CFM /person 20.00 CFM /person CFM/ft' 0.12 CFM/ft Carrier Hourly Analysis Program v4.04 0426/02 09:19 AM Page 1 Zone Name I Space Name Mutt Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Zone I 8.1 382 382 #1122 Main 1 4.7 Sep 1400 223 2.6 #1122 Loft 1 3.4 Sep 1400 159 1.4 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone 1 8.1 382 382 Sep 1400 3.9 • I Tree Sizing Summary for #1122 Sy' Project Name: Residence Inn Building #11 TuKvvila Prepared by: Neir & Associates, Inc. Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Coincident space loads Zone Sizin4 Data Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system Space Loads and Airflows Carrier Hourly Analysis Program v4.04 04/26/02 09:19 AM Page 2 r W tu O - OH W . fa Z co ~ O Z 1 Project Name: Residence Inn Building #11 - Prepared by: Neir & Associates, Inc. • Carrier Hourly Analysis Program v4.04 Air Sy m Design Load Summary for #1' 0426/02 09:19 AM Page 3 DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1500 COOLING OA DB I WB 82.5 °F 183.8 °F HEATING DATA AT DES HTG HEATING OA DB I WB 23.0 °F 119.2 °F ZONE LOADS Details Sensible (BTUIhr) Latent (BTUIhr) Details Sensible (BTUIhr1 Latent (BTUIhr) - Solar Loads 58 ft 3975 - 58 ft - Wall Transmission 521 ft 723 - 521 ft 1020 - Roof Transmission 627 ft= 775 - 627 ft' 904 - Glass Transmission 58 ft' 125 - 58 ft 1418 - Skylight Transmission 0 ft 0 - 0 ft' 0 - Door Transmission 21 ft 52 - 21 ft 592 - Floor Transmission 0 ft 0 - 0 ft 0 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 324 W 1105 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 5 1150 600 0 0 0 Infiltration - 0 0 0 0 0 Miscellaneous - 180 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 8084 600 - 3934 0 Zone Conditioning - 6434 600 - 3585 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 382 CFM 0 - 382 CFM 0 - Ventilation Load 100 CFM 569 -600 100 CFM 4925 0 Supply Fan Load 382 CFM 0 - 382 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 7003 0 - 8510 0 Central Cooling Coil - 7003 0 - 0 0 Central Heating Coil - 0 - - 8510 - » Total Conditioning - 7003 0 - 8510 0 Key: Positive values are cig loads Negative values are htg loads Positive values are htg loads Negative values are cig loads Project Name: Residence Inn Building #11 - Prepared by: Neir & Associates, Inc. • Carrier Hourly Analysis Program v4.04 Air Sy m Design Load Summary for #1' 0426/02 09:19 AM Page 3 • Project Name: Residence Inn Building #11 1 ukwila Prepared by: Neir & Associates, Inc. Air Sizing Summary for #112: ystem Air System Information System Name #1123 System Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 515.0 ft' Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 0 5 Tons Load occurs at Jul 1700 Sensible coil load 0.5 Tons OA DB / WB 84 5164.8 °F Coil CFM at Jul 1700 320 CFM Entering DB / WB 78.4164.3 °F Max possible CFM 320 CFM Leaving DB / WB 60.7158.1 °F Design supply temp. 55.0 °F Coil ADP 58.8 °F ft 1028.5 Bypass factor 0.100 BTU/hr/ftt 11 7 Resulting RH 50 % Water flow (@ 10.0 °F rise - gpm Zone T -stat Check 1 of 1 OK Central Heating Coil Sizing Data Max coil load 6256 BTU/hr Load occurs at Des Htg Coil CFM at Des Htg 320 CFM BTU/hr/ft 12.1 Max possible CFM 320 CFM Ent. DB / Lvg DB 60.7179.1 °F Water flow C 20.0 °F drop - gpm Supply Fan Sizing Data Actual max CFM at Jun 1800 320 CFM Fan motor BHP 0.00 BHP Standard CFM 315 CFM Fan motor kW 0.00 kW Actual max CFM/ft 0.62 CFM/ft Fan static 0.00 in. wg. Outdoor Ventilation Air Data Design airflow CFM 60 CFM CFM /person 20 00 CFM /person CFM/f? 0.12 CFMMt 04/26/02 09:20 AM Carrier Hourly Analysis Program v4.04 Page 1 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) 3.4 Zone 1 6.8 320 320 Jun 1800 Zone Name 1 Space Name Muit Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Zone 1 01123 - Studio A 1 6.8 Jun 1800 320 3.4 7-le Sizing Summary for #1123 Sy( in Project Name: Residence Inn Building 011 Tukwila 04/26102 Prepared by: Neir & Associates, Inc. 09:20 AM Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizinst Data Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system Space Loads and Airflows Carrier Hourly Analysis Program v4.04 Page 2 - Project Name: Residence Inn Building #11 Tufs.ala Prepared by: Nair & Associates, Inc. • Carrier Hourly Analysis Program v4.04 Air Syr' , m Design Load Summary for #1'' System 04/26/02 09:20 AM Page 3 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB I WB 84.5 °F 164.8 °F HEATING DATA AT DES HTG HEATING OA DB I WB 23.0 °F 119.2 °F ZONE LOADS Details Sensible (BTUIhr) Latent (BTUlhrl Details Sensible (BTUIhr) Latent (BTUIhrI Solar Loads 50 ft 3361 - 50 ft - - Wall Transmission 421 ft 548 - 421 ft 825 - Roof Transmission 515 ft 967 - 515 ft 743 - Glass Transmission 50 ft 171 - 50 ft2 1222 - Skylight Transmission 0 ft 0 - 0 ft 0 - Door Transmission 21 ft 83 - 21 ft 592 - Floor Transmission 0 ft 0 - 0 ft 0 - Partitions 0 ft 0 - 0 ft 0 - Ceiling 011 0 - 0 ft 0 - Overhead Lighting 216 W 737 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 690 360 0 0 0 Infiltration - 0 0 0 0 0 Miscellaneous - 152 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6708 360 - 3382 0 Zone Conditioning - 5534 360 - 3295 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 320 CFM 0 - 320 CFM 0 - Ventilation Load 60 CFM 475 -360 60 CFM 2961 0 Supply Fan Load 320 CFM 0 - 320 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 6009 0 - 6256 0 Central Cooling Coil - 6009 0 - 0 0 Central Heating Coil - 0 - - 6256 - » Total Conditioning - 6009 0 - 6256 0 Key: Positive values are clg loads Negative values are Mg loads Positive values are Mg loads Negative values are cig loads - Project Name: Residence Inn Building #11 Tufs.ala Prepared by: Nair & Associates, Inc. • Carrier Hourly Analysis Program v4.04 Air Syr' , m Design Load Summary for #1'' System 04/26/02 09:20 AM Page 3 . Project Name: Residence Inn Building 011 '1. Prepared by: Neir & Associates, Inc. Air�system Sizing Summary for #1124 S'!em Air System Information System Name *1124 System Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 810.0 ft' Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 0.5 Tons Load occurs at Jul 1700 Sensible coil load 0 5 Tons OA DB / WB 84.5164.8 °F Coil CFM at Jul 1700 290 CFM Entering DB / WB 79.5164.4 °F Max possible CFM 290 CFM Leaving DB / WB 81.8158.1 °F Design supply temp. 55.0 °F Coil ADP 59.8 °F ft 1778.4 Bypass factor 0.100 BTU/hr/ft 6 8 Resulting RH 50 % Water flow @ 10.0 °F rise - gpm Zone T -stat Check 1 oil OK Central Heating Coil Sizing Data Max coil load 8330 BTU/hr Load occurs at Des Htg Coil CFM at Des Htg 290 CFM BTU/hr/ft° 10.3 Max possible CFM 290 CFM Ent. DB / Lvg DB 53.2180.2 °F Water flow @ 20.0 °F drop - gpm Supply Fan Sizing Data Actual max CFM at Jun 1800 290 CFM Fan motor BHP 0.00 BHP Standard CFM 285 CFM Fan motor kW 0 00 kW Actual max CFM/ft 0.36 CFM/ft' Fan static 0.00 in. wg. Outdoor Ventilation Air Data Design airflow CFM 100 CFM CFM /person 20.00 CFM /person CFM/ftt 0.12 CFM/ft 0422/02 02:31 PM Carrier Hourly Analysis Program v4.04 Page 1 Zone Name/ Space Name Mutt Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Zone 1 6.2 290 290 #1124 Main 1 4.1 Jun 1800 193 2.6 #1124 Loft 1 2.1 Jun 1800 97 1.4 Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) 3.9 Zone 1 6.2 290 290 Jun 1800 Si Project Name: Residence Inn Building #11 1 wtwila Prepared by: Neir & Associates, Inc. Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizing Data Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system Space Loads and Airflows Carrier Hourly Analysis Program v4.04 — one Sizing Summary for #1124 S �'em 042/2 02:31 PM Page 2 Project Name: Residence Inn Building #11 Tu, wila Prepared by: Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 Air Sy' mm Design Load Summary for #1 — t System 04/22/02 02:31 PM Page 3 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB I WB 84.5 °F /84.8 °F HEATING DATA AT DES HTG HEATING OA DB I WB 23.0 °F 119.2 °F ZONE LOADS Details Sensible (BTUIhr) Latent (BTUIhr) Details Sensible (BTUIhr) Latent (BTU/hr) Solar Loads 58 ft 1520 - 58 ft - - Wall Transmission 521 ft 529 - 521 ft2 020 - Roof Transmission 627 ft 1276 - 627 ft 904 - Glass Transmission 58 ft 198 - 58 ft 1418 - Skylight Transmission 0 ft 0 - 0 ft 0 - Door Transmission 21 ft 83 - 21 ft 592 - Floor Transmission 0 ft 0 - 0 ft' 0 - Partitions 0 ft 0 - 0 ft 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 324 W 1105 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 5 1150 600 0 0 0 Infiltration - 0 0 0 0 0 Miscellaneous - 180 0 - 0 0 Safety Factor 0% /0% 0 0 0% 0 0 » Total Zone Loads - 6041 600 - 3934 0 Zone Conditioning - 4671 600 - 3430 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 290 CFM 0 - 290 CFM 0 - Ventilation Load 100 CFM 801 -600 100 CFM 4899 0 Supply Fan Load 290 CFM 0 - 290 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5472 0 - 8330 0 Central Cooling Coil - 5472 0 - 0 0 Central Heating Coil - 0 - - 8330 - » Total Conditioning - 5472 0 - 8330 0 Key: Positive values are cig loads Negative values are htg loads Positive values are htg loads Negative values are cig loads Project Name: Residence Inn Building #11 Tu, wila Prepared by: Neir & Associates, Inc. Carrier Hourly Analysis Program v4.04 Air Sy' mm Design Load Summary for #1 — t System 04/22/02 02:31 PM Page 3 LICENSE DETAIL INFORMATION Form Page 1 of 1 STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License KDMECI *008CJ Name K & D MECHANICAL INC Address 1911 S W CAMPUS DR. 321 Address City FEDERAL WAY State WA Zip 98023 Phone Number 2539458204 Effective Date 2/11/2000 Expiration Date 2/7/2004 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code AIR CONDITIONING Other Specialties COMMERCIAUINDUSTRIAUREFRIG UBI Number 601994103 * * *VIEW CROSS REFERENCE FILE FOR THIS LICENSE* * * * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * 'VIEW *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page https: / /wws2 .wa.gov /lni/bbip /TF2Form.asp ?License= KDMECI *008CJ 09/26/2002 RISER DIAGRAM VIEW C) SEE PLUMBING RISER 5HEET M -2 FOR PIPE SIZES I —SEE S!M ?L.AR :AVI'' I FOR HVAC STup o UNIT "A' tg1.3 P -3 � ���11 SEE SIMILAR UNIT I FOR HVAC 4 311114■, 3/4 "H 4 CWDN TO BELOW SLAB TYP 6 ' m EXI DUCT STUDIO JM T "5" #11 :2 'T - 1 I P P -5 � TYP LOWER FLR HVAC `A"OUT - - - - - g -p T 'T -- 1 — I T - 1 -- 1 1 1 1 1 1 1 1 1 I I I I I I t I l I I I I I I t t L _1 1_-L.£ 1 2 " Nvr ,, N FROM AB P-5 CP-b� I-1/2 ✓ UP 1 0 1 op h - 7 'I f I tt F^ d d P-5 P-6J TWR - 150 GFM 00 0 0 I 1 I I I I I V I STUDIO UNIT "A #1111 T - T1 ' - T I t t 1 I 1 t I I i I t 1 I t I I I I I t I V SEE SIMILAR UNIT FOR HVAC I - I/2 ✓�_UN1T EXHAUST FANS BY OTHERS (TYF' ALL UNITS) I4X8 EXHAUST LOUVE L _ -1 (TYP ALL STUDIO UNITS] MAINTAIN 3 rT MIN. DISTANCE TO BLDG. OPENINGS 5TU1:710 UNIT "B'' *11r4 CD-10X10 27 CFM b ". EXHAUST FIRST FLOOR PLAN - HVAC & PLUMBING SCALE: I /4" = I' -O NOTES: 1. t3ELOW SLAB PIPING 15 EXISTING 2 IREA "? ✓E SLAB AS REQUIRED 3. VEP.'r'Y THAT THE STUBS ARE NOT CRACKED OR BROKEN. 4 '✓EF "r THE USE Or EACH STUB I CONNECT NEW WIPING TO THE APPROPRIATE STUB + STUBS THAT ARE CRACKED OR BROKEN BELOW THE SLAB FOR GONNEGTION AT 600D PIPE b iF THERE ARE CONFLICTS WITH STUB 4 WALL LOCATIONS, CONTACT ARC-+t "EGT FOR REG ^' J./TIC"' S 8X8 P -2 BLDG R CONT. B OT R S II r44-1) MAIN SHUT OFF VA. FOR BLDG REFRI6 PIPIN IRUN IN CEILING SP PE I REFRIG PIPING U° I ti WALL TO JPPE � Ql 2 "C W(CONT BY OTHERS) EXTEND DUCT Ti® INTAKE INSTALL MOTORILtV LOW LEAKAGE DAMPER NEAR END OF DUr,T. INTERLOCK FAN -COIL UNIT FAN -- 1 4 "X8" OUTSIDE AIR INTAKE LOWE (TYP ALL STUDIO UNITS ON FIRST FLOOR) (' cal i RISER DIAGRAM VIEW S FILE COPY By Date ? z C <Z Permit No. 1' tO L O- SEPARATE PERMIT REQUIRED FOR: C-} :CHANICAL [V ! CTRICAL [Y /t ±IVIBING ()AS PIPING CITY OF TUKWILA BUILDING DIVISION O I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractors copy of approved plans acknowledged. 571710 UN "A" #'�23 I -I/2 P -3) SEE SHT M -2 FOR HVAC 4 PLUMBING ABV. CEILING - I- 1/2"V. UP FROM BELOW 1..OFT UNIT "C" #',22 PAN 1100, M t\Y 2 t 2002 hau Lo r 1 -3/2 V iJP ®FLOW nEVi3 ONS 4 "WDIN 'P -3 NO CHANGES SHALL BE MADE TO T; - '= SCOPE OF WZi K WITHOUT PRIOR D��L O' TUKWILA BUILDING DIVISION. ' 5 w1LL REQUIRE A NEW PLAN SUBMITTAL • ' - "AL. PLAN 11VIEW FE- S �0 O 00 '1,-41F ri M BELOW DN I -1/2" V UP FROM BELOW 2" VTR-' j`.OFT UN T "C #;'2 I I -1/2' V/ UP 1 BELOW -:,2 V ABV GE�IN6 1 -1/2" W ON 1 -I/2' V/ UP FROM BELOW LOFT UNIT "A" #1121 P -3 BELOW SECOND FLOOR PLAN - HVAC & PLUMBING SCALE: 1/4" = I' -0" M -2 FOR PLUMBING 3/4" H 2" GW DN IN WAS_ I -1/2" UP FROM -` --- EXTEND DUCT TO G -! NTAKE. INSTALL MOTORIZED LOW LEA DAMPER NEAR END OF DUCT. INTERLOCK WITH FAN -COIL UNIT FAN. >TES: INSTALL FLOOR DRAIN SO THAT RAISED FLAN6E OF STRAINER TOP , S FLUSH WITH FLOOR SURFACE. CAULK JOINT. TYP FOR ALL Nf;,,W CONSTRUCTION MARRIOTT RESIDENCE INN TUK✓VI LA V' A 1 '4EIR 4 A$SOGiATCS V 42 - bbb -614O s120 I4'I'TH AVE. SE Pm 436444 *164 SAMMAM15H, AA 18015 E. "4'1'4.'411'4 cd" 3/4" H 4 CA ASV CEILING RECEIVED CITE' OF :,JKW,LA MAY - 1 2002 PERMIT CENTEF, 44 "X8" OUTSIDE AIR INTAKE LOUVERS ! -i (TYP. EACH STUDIO UNIT ON SEGONr' o c-Fn1 CONTMER MO�-095 OiM,40 Mi It M -I sw1.e. A3 NOTED rotooe, sY A.J ',Are; 4 -2b-O2 e ,sea FIRST 6 SECOND FLOOR PLAN -HVAC t PLUMBING REFR> GER. N o, P. NC + °X 2. CouCT 4 . . BETWEEN C R AIR c FLOOR TREATED LUMBER BLOCKING WHERE REVD. FOR DRA 1 NAGE CLEARANCE TYPICAL FC -1 INSTALLATION DETAIL SCALE: NONE (P 3' EXTRACTONEI APPRC X. ' ' -4' CEILING — FLEXIBLE CONNECTION —FAN-COIL UN.T WITH COOLING COIL - --WALL MOUNT FAN -COIL L*4 T AS HIGH AS POSSIBLE, VERIFY HEIGHT FOR "ATER HEATER CLEARANCE CONTRACTOR T'7 PRO` VE VIBRATION ISOLATION !RUBBER IN 5h£AR) KEEP SOTTO(f FRONT OF ',MIT CLEAR FOR FILTER REmOV 4L A TRAIN DOWN TC FLOOR ORA i k. DO NOT OBSTRUCT ACCESS TO WATER -EATER OR FAN -COIL UNIT WATER HEATER B`' F LUMBIN& CONTRACTOR SEE DETAIL ON SHT Q t 0 46"r A— A h .7h OF - TE c '4EA"F_R AN—CO Fv' T I ASSOC 1 A' E::: PIP.H6 3I 9& _ NOT REC RE ACCESS OQ RE` - /A` O E TEM h \ f ° 4 \, v I ° , I1 I \� 11 I \ °° I i °\ h (P _ d p �2) ' t./ V 1 � N oti LOFT WATER RISER WASTE & VENT RISER NO SC AL E RISER DIAGRAM VIEW REFRIG PIPING DOWN IN WALE_ SEE S-4T M -I E EXTEND DUCT T FC-1 INTAKE, INSTALL MOTORIZED LOW I_EAKAGE DAMPER NEAR END OF DUCT INTERLOCK WITH FAN-COIL PAN O } T TO FR ABOVE \® ,t FR 6 X14 200 fFM 1 -1/4' GW DN. 60 EXH. Jp EXHAUST F Ar tit (B' OTHERS, (TN-1 10300 EXXHzAUST C?'JC.T L TO . 14/TONE st345 ROOFCAP TYP. LOFT PLAN - HVAC & PLUMBING D IOxIO 200 CFM _ VERIFY LOCATION_ OF ALL_ T- STATS --- IN/ARCH, TYP LOFT UNIT C. *1122 ti HI HI�t7 MANUAL VOLUME DAMPER, TYP SECOND FLOOR/LOFT SUITE PLAN -`HVAC & PLUMBING SCALE: 1/4" = I' —O" J SCALE: I /4" = 1' -0" P -3 ti 61P =x74AUST UP FROM BELOW a 095 14 "X8" OUTSIDE AIR INTAKE i_OL (TYP. EACH LOFT UNIT) t C C' C1 1 LOFT JNiT "C" ttlj24 3" V. UP TO LOFT I -1/4" CW UP TO LOFT UP TO LOFT TO LOFT SEE SHY - ! I M - FOR PIP',NG SIZES L !EXPIRES /j - GPI `14 11Writu MAY 2 8 inn U MARR.IOTT RESIDENCE INN TUK.V4I I LA INA RECEIVED CITY OF KW ILA MAY - 1 2002 PERMIT CENTF'.. fx.All, AS NOTED ` °'Rlwr+K A.J. mil. 4 -26-03 SECOND FLOOR /LOFT PLAN —HVAC e PLUMBING NEIR I A3SOG iATtS v 42 - 66e - 6; 40 20 -1471H AVE. SE f. 42, a M � 2 3AMMAM19H,_ WA AbO15 8. nawcw°ttbl com [1014441. 4 ■ 1/ P -2 -1 --.._ X314" P 3/4 ' P -I P -2 P -3 P -4 P -5 P-6 P -� D -+ 4 - , I Cy P-! FIXTURE or SYMBOL '- yGONNECT '<'' "(.4s T R O iCEMAKE ... NO SCALE 3: "' 4 ✓W - PLUMBING F ctONNECTIQN 5GHE1?lh..E DESCRIPTION W.0 .(TANK) LAV. TuB /SHOHER DISHWAS E-R KITCHEN SINK DISPOSAL 0 WALL HYt2RANT FLOOR DRAIN 4 1 -1/2" 1 -1/2" I -1/2" 1 -I/2" 1 --1/2" 2 „ 1 -1/2" 1 -1/2" INDIRECT 1 -1/2" 2" I -I/2" a / f 2' '1. 1/2" 1/2" 1/2" 1/2" 1/2" ..2 °` - -_ !/2 "(TYP 4) LOCAL CONNECTIONS r P -4? WASTE VENT , HOT WATER GOLD WATER 1/2" 1/2" 1/2" _ � 4 -C.0 GT ./2' - 0 10EMAKER HOT & COLD WATER RISER FIRST & SECOND FLOORS 5/4" TRAP PRIMER • 1 -I /2 a/4' !"CH ,..- / / I- I /2 "CW , >GONNECT i ----\„ N...____ P - - /-- ? 4 TO ICEAKER � P 5/4'14W - 2 "CW SERJ (CONT. BY OTHERS 5 ' - o" OUTSIDE BLD'G.; --MAIN SHUT OFF VA FOR BLDG. t--1/2•!-, 3 "VTR I \ � L � 1 I 2" L {� '. t-1/2" � 1 1 I -I/2'� n ■ 2"V-- I �I -1/2` ■ M SA-'F '/ /E •'""" " .A..._ • 3/4 UN =ON 'TYP CAI-) I� VAL /E _ - _._ S4DE OR TOP; cyj P4 T RELIEF P ±PE FULL SIZE TO FLOOR AIR-GAP PITTING �— TYP TO P -5 TYP. WH -1 & WH -2 PIPING DETAIL 3 " VTR._ 1 � C2 „ NO SCALE 4'„._ 95 T' , �i v %, X 3,. M! XED HW AT �G'F - HERMOP'fETE`c ` 3/ C;1 IN 41W DN FROw 4 LOFT 4" I SEE FLOOR F__ ANS FOR _OGAT;C WASTE & VENT R ISER FIRST & SECOND FLOORS NO SCALE IN. 0 oil VA. f -I /2 I -1/2" ■ td-V2" 2 " 1 -1/2 2 : 1 -1 1 � 1 1 - I/2, - 1 2 . 1 r 4" r— t 4' FLOOR BRA :'v c''R \1 E THE A ED !nC'Ot7 iNDER ,',A — ER HEATER. 2 SE- yW'EER - MPERA : vR5 ANT 55 °F 5. ALL PtP',NG CONNECTED 'O r,4 -EA A__ OR T! =A©Ev A LEX SLE CONNECT QttiS. ,P -2 l -I/2" O *IE. _ 4- 26-02 1 E !- t/2 "--I f P -2 MARRIOTT RESIDENCE INN TUKINILA, wA MAY 2 8 2002 k-` AA RECEIVED CITE OF TUKWILA MAY - 1 200? PERMIT CENYFr, sGM. AS NOTED oRnv« er A .J. PLUMBING RISER DIAGRAMS, SCHEDULE 4 DETAIL EXPIRES /1 - // - 0 4 I NE1R 4 ASSOCIATES v ,y;1y_ 8140 oRVw�s �s�ee X1 20 -141rN AVE 3C SAMMAMISH, WA 4 18075 E. nolr P. 42S-845e)-61154 a•attbl can M-3 lX drt:2.NT ' SPECIALTIES. .. .`. Auk. '"i"_ "li{, ., _ • 'i oR.'• x. _ ._ •- /E L+ ' aP - R aK. J a Ac REA=A.RS ExTE'D , £ e. R � ._ : + G3*'S+' - x? :?^4: _ : • .T?•E :° T 7E ***'' A5' E. _' OF 1415 WD■t• - C - - »r=. - x -- :.«R vr'i. E3 D , iii• - BE A5r_-i.N.E.O -A- HIS SID 'NCI_LID -•. -- -.'�'. ._.e. - ,.,+r-w:.- •,.:� 4.�'.. =Q .. ° Q;;✓":. A ...:' .C:�_ "r AC; S'r .hr.; a.�'�B•irS ✓`ORA INGLJG'•kt -a' _. �.'�.`. ��./�.. '... .i " -t.' �ST �1.'r C_. 'L!'i TG . �a ✓Y '; ./•t.�.. �+4.' �. \ ":-'L �.�'�: NI.Hi✓_jT N.T. GA- AL_ PERm'S A1' ,N C 1t ' ' _ A++� =^ -.Lae PRE /IOUS 91.'L.D NO OItS REOU•R>?.. FOR THE NORK • - OPEN, D .N6 H' i ` 4TH ► 'C P G AN'GAL GON SHALL HE RESPONSIBLE FOR ALL GJTT'►1fi AND NORM AND SHALL SIJ ER 5E � .i+� ,-7'R G' r+Of2i: S r f3Y OTHERS A.. REQUIRED 5^ -AIL_ $€ 4PPy- Over. -� B'- THE Alec ;TE'.' PRIOR To o R3)ERII-t Se18M'T WITHIN TEN (0) AS OF CON'TRAGT AWARD, F•VE COP +ES OF SUBMITTALS SHOWING DETAILED DESCRIPTIONS CC. _,xT�iRES 5.9VPMENT AND t•ATER:ALS DESI&'ATI P ON TIME PLAN ;IF. MANUFACTURERS NAME, CATALOG NRS 2. SUBMITTALS SHALL 5E REVIEWED BY ARCHITECT PRIOR TO EQUIPMENT OR ' iNG G NSTA 'aOiti: CONFORM WITH ALL h1ASUFAGTURER'S !RECOMMENDATIONS AND ACCEPTED D TRADE PRAGTIGE:S 2 AL.L J.sG' DIMEN5,0145 SNONN OIy DRAr{1NG REPR T WE F .EE AREA NGREASE AS REGvIREG WHERE LINED 3 ALL MX TOORK 54ALL 9E FABRICATED AND 445TALLED IN AC.GOfRGANCE WIT" SMACNA LOW VELOCITY STANDARDS 4. INSTALL A I4A 4iAL VOLUME DAMPER FOR EAC + AIR TERMINAL AND WHERE SHO1'NN ON DRAWING OR REQUIRED FOR PROPER BALANC N5 OF VENTILATION SYSTEM. PROVIDE FRICTION TYPE- DAMPER WITHIN 16. OF OUTLET FOR ALL TERMINALS INSTALLED IN NON - ACCESSIBLE CEILINGS 5. APPLY A PERMANENT LABEL WITH MINIMUM I -1/2' 1+16111 STENCILED LETTERS ON ALL EQUIPMENT WITH UNIT AND GUEST ROOM DEli16hATIONS. 6. ALL E MMPMENT FIXTURE PIPING AND ouon IIORK SHALL BE SEISMICALLY RESTRAINED PER SMACNA AND LOCAL GODS QEQU+QE1 . •1. INSTALL REFRi ANT "PINS PER MANUFACTURER ?5 RECOMMENDATIONS AND APPLICABLE CODES. 8. °ROVIDE /ALVIN& TO ALLOW FOR REFRIGERANT IRECON/1512Y TO MEET CURRENT GODes. q. INSTAL I';.DOp :"RAINS IN OPEN AREA OF CLOSET 50 ItIAT THEY ARE NOT COVERED BY WATER HEATER. .F AN EXISTING FLOOR DRAIN MILL BE COVERED BY A WATER HEATER, INSTALL ADEQUATE BLOCKING UNDER NcATER 11E•ATER TO ALLOW FOR RELIEF VALVE AND CONDENSATE PIPING DISG"ARGE 10. INSTALL TRAP PRIMER FOR ALL ABOVE GRADE FLOOR DRAINS, IT IS BELIEVED THAT THE EXISTING BELOW GRADE FLOOR DRAINS IN THE FLOOR SLAB WERE R'RIMED. CONTRACTOR SHALL DETERMINE IF THE WERE PRIMED AND IF THERE 15 AN EXISTING PRIMING LANE THAT CAN BE REUSED OTIIERRI'NiSE, THE FLOOR. DRA'1 S IN THE FLOOR SLAB WILL NEEL) TO BE REMOVED AND PRIMED II. ALL VISIBLE PIPING THAT EXTENDS THROUGH FLOORS. WALLS AND CEILINGS SHALL HAVE THE APPROPRIATE ESCUTCHEON INSTALLED 12. MEGNANICAL CLOSETS ARE E=XTREMELY SMALL INSTALL THE FAN -COIL UNITS AS H16" AS PO LEAVING ENOUGH! GI_EARAN:E FOR THE WAT7_'R HEATER AND ITS ASSocIATED PIPING INSTALL ALL PIPING TO ALLOW QUICK REMOVAL OF WATER HEATER AND SCRRViGIN& OP THE FAN -COIL UNIT, ELEGTR'GAL GLEAAF.i -\1 AI() AIR FLTE}RS_ IIVSTALi PIPING AROUND THE PERIMETER OF THE CLOSET AND MOUNT VAL MS ON THE WALL TO ALLOW MAXI1.4014 C.LEARANC -ES. 15 BRING ANY CONFLICTS TO THE ATTENTION OF THE ARGINTECT FOR RES OU./T'ION. H. 2e _1NAT70N: THE MECHANICAL COMITRAGTOR SHALL GOORDIINATE EQUIPMENT SELECTION AND INSTALLATION WITH ALL OTHEW GRAFTS SO AS NOT TO CAUSE INTERFERENCft WITH ITEMS OF CONSTRUCTION NOT RELATED TO MECHANICAL SYST'Et Et-FAIT SCHEDULE ON PLANS REPPIEP2ENTS THE TTVE AID STAN:ARD OF dUALIT'' OP EQUIPC'MENT TO DE PRIOVIDED ALL. EGIUIPM!!NT SHALL BE UL LISTED AND APPROVED FAY LOCAL CODE FOR INSTAI„LATION. 2. GEILIN6 PIFR.13EW (c-Q): MODULAR. GOIRL OMR/SEW SQUARE, MOVABLE CORPS, OPPO"ED BLADE DAMPER, SURFACE MOUITTep WITH VANDAL PROOF Sic*REre 9T>C!d, GORE AND ALUMINUM FRAME, "SOFT WIHTF. SHOEMAKER MA seiti Es on /+PPROvww • JP NrAi _ RE6. siT' Il -rot, evotnG+►._ •Mc HoR_ZoNTk STEEL S,AtJES ADAISTAIBILE FA! '3 OR ANNOY A+ : > &,.gFEN g 4. .0.+. 'p'4aaCJF u ✓.i•L J q,f. ERE F i .24 �� .►. r . 00R RE TSTtiR 'Tq' fa... Ski S'M._ PARALLEL BLADE 7Am'�t ANC' OPa BIr.Ak :2AMP9R - '+C fD"C 4 Z.1i Y 2° ORAP*•- rt•K4C' IFLE►. OE AAE R nAt uses WATER A% Q : A'v STAN+. ARD OCAVET °2848 012 *1-00R MOUNTED FUGH ''ANK. ELONGATED nw b €aA J OP F_ .S. SEAT BIE' 5' IAl2OO R. 4- 0H15A"E_. t.. FRONT NITH .iyER SOL:v °1. ST rNr+ - W.: H r.+c CHECK -a'"+ff. �• ?,' i A /ATORY AMERaGAN STANDARD, OOVAL'rN 11A •0446.OI r X i4a WHRTE, J: T1 tw.e ORNA F;TTI rye AMLR!GAW 5TANDARA, OREi:ANT■ i-2365.00,3„002 50 C.O4TWOL .tANo- Nil- GiR -D DRA•>ti. *ERA - OR ,HD "LO+++ RE5 R'GTO�'i PER .'.00R '^JRA:N Pe+Nt5., NIPS +. NPS -.r2 GHRO7'"tE PLATED CAST SRAS5 TRAF THICK TUBULAR'. BRASS HASTE TO r1ALL AND NALL ESCUTCHEON S PPLI P 3 /b* .D►+ +O.• CARO.E- P'..AT COPPER ,. Th j'OF OES/9404.4ER AMERICAN STA NOARD. 15AL$ " A. 0 0 ,1 55 O••' OR *0l5 ' r:45, r*i;TE. ENAIHELEO STEM_ SLIP R rtlTi± ACGESS+BiLTY GRAB BAR AND BEltiCH. FITTINGS AMERICAN STANDARD ORE- ANT. Ii445'S55OI.002 V ALVE 111 OREL=ANT. •666. 02.5.00'2 DIVERTER SPOUT At4o v'IATE!!P'K *SM -550 SHONER HAD F . EXIBL E '49E AND F:TTINGG DRAIN +S I -I/2° (D t4 40, GFRorE EXPOSED PARTS BRASS POP -UP WASTE Ali) OVERFLOPt SUPPLIES: MPS 1/2A (ION 15) GOPPOR TL61N& WET" BALL. SATE OR , ..3LOBE VALES D I° SHER. SE 'D2000ZAD, 34 H X 24' rl X 26e D, 4 CYCLES/1'T OPTIONS. PERMATUB AND 200R. SOUND INSIJLATy - MOND FINISH 500 WATT DRYING ELEME47 1 14P MOTOR 20?F INLET WATER TEMPERATURE 35 GPM CIRCULATION ) i• 4 64. FACTORY ATTACHED DRAIN HOSE. 'I AMP, 120 /AC, 60 ++Z, UL LISTED. six FOOT POWER CORD WITH 3 -PRONG MALE PLUG. (P-5) Grrci N SINK: 13-KAY, OCELEBRI"!A, 0 12CR- 2522 -40, I- GO'M{PARTHENT, 20 GA. STAINLESS STEEL 25. X 22 x WITH 4 FAUGE' HOLes F`TTTNBS: ORELIANTA, A4205.001002, SINGLE CONTROL LEVER HANDLE WITH SPRAY AND LIFT AND TURN DRAIN AERATOR AND FLOW RESTRICTOR PER CODE DRAIN PIPING: NPR I- I /2A (DN -40) CHROME PLATE) CAST BRASS TRAP. 0.043 THICK TUBULAR BRASS WASTE TO WALL, CONTINUOUS WASTE AND Kau.. ESCUTCHEON. SUPPLIES: NPS 412 (DN 40) CHROME-PLATED COPPER WITH STOPS (P-6) DISPOSAL IN- SINK- ERATOR 6 BADGER IA WITH r1ALL SNITCH CONTROL, b? LONG CORD AAD MALE PLUG 1/3 HP 115 VOLT (P- WALL +rYDRANT. PRO.ZGTING r' NICKEL BRONZE, NON - FREEZE, WITH INTEGRAL AND DRAWABLE VAGUJ• BREAKER, KEY OPERATION. PROVIDE ONE KEY. ANSI AI12.21.310. INLET: 7. THREAD$? OR SOLDER JOINT. OUTLET: GARDEN HOSE THREADS. J. R. 5MmT 1. 05604QT OR Apmcmt,ovEp (D-I) FLOOR DRAIN: 2. OUTLET, ROUND TOP FLOOR DRAIN AND NICKEL BRONZE ADJUSTABLE STRAINER 'NTH RAISED FLANGE. ZURN *Z -415 -P WITH ®TYPE 51A STRAINER AIL: ?A PRIMER GONIEGTION. INSTALL WITH TOP OF RAISED FLANGE FLUSH WITH FLOOR SURFACE TRAP SEAL I°RIMeR VALVE: ASSE 1016. WATER - SUPPLY -FED TYPE WITH BRONZE BODY AND ATM05PHERIc-- VENTEC DRAIN CHANTER. 7A NPS (ON 15) THREADED, UNION OR SOLDER JOINT INLET AI, OUTLET GONNEGTIONS ?A NPS (ON 15) THREADED OR SOLDER -X2INT GRAVITY DRAIN OUTLET CONNECTION. -'RECISION PLUMBING PRODUCTS *PR- 500 K MATEl2:AL5: I. DUCTWORK. GALVANIZED STEEL WITH &AGE PER SMAGNA STANDARDS. 2. FLEXIBLE DUCTWORK: SHALL BE SPRING ST'EEi.. HELIX WITH INTEGRAL GLASS FIBER INSULATION AND VAPOR BARRIER FIVE (S) FEET MAXIMUM LENGTH RAINS ASSEMBLY SHALL MEET GLASS 1 REQUIREMENTS OF NPPA BULLETIN 90A AND BEAR UL LABEL_ OFF. •2002- 06- Sx04I1 • 3. ALL RECTANGULAR DUCTWORK SHALL BE LINED AND ALL ROUND DUCTWORK SHALL HAVE INSULATION WITH INTEGRAL VAPOR BARR.1ER THAT MISTS LOCAL ENERGY CODE REQUIREMENTS. 4 DRAIN, WASTE AND VENT PIPING M+AY BE ABS PLASTIC PROPERLY PRIMED AND SOLVENT MELDED 5. ALL OTHER ABOVE SRADE PIPING INCLUDING CONDENSATE DRAIN LINE FROM FAN-COIL UNIT SHALL BE TYPE L COPPER. L. G1t.ANGIN6: I. PRIOR TO FINAL_ INSPECTION AND AGGEPTANC.E, THE MECHANICAL CONTRACTOR SHALL BALANCE THE HVAC SYSTEM TO THE SATISFACTION OF THE ARCHITECT 2. PROVIDE COMPLETED GOPY OF BALANCING REPORT TO ARCHITECT I" I lTl?Q1 ,t, I. FAN -COIL AND HEAT PUMP UNITS: SHALL BE OPERATED WITH A SEVEN (T) DAY PROGRAMMABLE, TWO STA®E HEAT AND ONE STAGE COOL 24 VOLT THERMOSTAT HONEYWELL T850ID OR APPROVED 2. MOTORIZED DAMPER FOR OU'T'SIDE AIR SHALL OPEN HIEN FAN -COIL UNIT PAN IS ON AND CLOSE WHEN PAN 15 N. fiRithAtestill& QUARANTL'+E MA/VICAL.AJ AND WORKMANSHsP FOR A PC1RI0 ' OF ONE YEAR PROM DATER OF FINAL ACCEPTANCE , 'III - °I.:' -4-- -2 iNATE>Z jHEAT I MOO5 • r � w • (EXPIRES // // -0 ( 1E�GRIVT.�N - F__OsA4 ''00 : 6 0 5 E S. -.0S5 "5 / -4c � r'AN m T Rr-L- ./"R / /r%+/:. J -kF k s -, v h/A - ✓V�i ./✓ Jai t� �'A► 5 auto , fE 2.08 ! w a - 5 `.f^t 6 2019 / AC,C 'SAT �►`� r ARR. - _ } - - - - - ''�`... THERMOSTATIC ANTI- SCALD, AD..I_STASLE TEN.IP RAN- GE RE RANE QO ° F -i2r'. `' ` 05 _ ' '� x•tiG ✓A MII'vIMt)T -' FLOYN RA 8 GPM 'Ax.! -1U-A ^LOS RATE. ill GONNECTlONS 1 !MATER ELE , TRIG 50 GAL-ON STORAGE A ; " c -1 �. ,� ORA,�E .,.AP .., � _L. *�EN�.. _. �. AT f� .rl , 1+9 r1' RE A M ER R 5 ST AKCAR.D 5 AND EART+L:o.AK = R• -S .A yT DIY , i iti.ov4 A Appaotko MAY 2 8 2032 Az) 1%.,;(-) rr • MARR,OTT RESIDENCE INN TUKAILA, WA NEI* t A3£�OGiAt'ES v 425 -068 -6440 a20- Iq`7 AV'E SE F 425 -666 -6164 SAMMAMISit WA alteaT5 - E r com • 5.4Arc C A� mo...ftq-Er' T p C`TA� :i00, GAPAG •�I' =:L' A M'i' SENS'BL_ 3 GARR'.E - 3 'ASH d &O'e r EAT 8.5 ° r _ 0 A NimuNe R , AMPAC -„ = 3 5 A c 20$ y SEER = EER = s0 :�P =3.08 PF 8G tt ••_ T.3v/fC DEL +`' RE_ A-' _ /APO ATOR 7 5RFI 11 -eRNAOS'AT R -CLOY+ T x / � vL �C?ER 4 SL.'OR ► rET. . 83; . * N.. )^4ELL. ARv0 { A O. SMI , k DEL -50 ELEC- TRI.S, 80 GAL LO\ SYORAGE CAPAC T" 2 ELEl NTS EACH AT 5Kl^; 208V.. 14) Wt'-± I A.G.S'ri'TH ' MFR.'S STANDARD COMPONENT'S AN E ARTt- ,QL,AKE RESTRAINT t i3EN -bO HVAC NOTES I. ALL INSULATION AND LINING SHALL MEET THE CURRENT WASHINGTON STATE ENERGY :,ODE REQUIREMENTS. 2. FLEXIBLE DUCTWORs:. SHALL BE INSTALLED FREE OF SHARP BENDS AND TC A MAXIMI M LEND 7 - OF 4 FEET AT EACH AIR TERMINAL. 3. ALL MECHANICAL EQUIPMENT SHALL BE VIBRATION SOLATW TO PROVIDE NO OBJECTIONABLE NOISE IN CCCCLJPIED SPACE. 4. OUTSIDE AIR INTAKES SHALL BE ADJUSTED FOR TIDE AIR QUANT!TIE 5t-OWN ON PLANS. 5. ALL 40 ;^"UCT TURNS SHALL HAVE LONG RADIUS E -SOW CR HAVE TURNING VAt UNLESS SOWN OTHERWISE b. CEILING SPACE AND MECHANICAL CLOSET 15 EXTREMELY LIMITED. COORDINATE ALL WORK WITH OTHER TRADES TO PREVENT CONFLICTS. PLUME3I NG NOTES 1. DESIGN DRAWINGS ARE BASED ON EXISTING GOND T'ON5 AND INFORMATION FUR: 'SHED TO THE ENGINEER. 2. ALL WORK SHALT_ GOMPL Y WITH THE CURRENT UNIFY PLUMBING CODE AND WASI- 1`JGTON STATE ENERGY CODE. 3 FIXTURES ARE TO BE INSTALLED WHERE INDICATED ON ARCHITECTURAL PLANS, COP ETELY OPERATIONAL AND !N COMPLIANCE WITH CODE. 4. FOR FIXTURE BRANCH, DRAIN AND VENT SIZES SEE - IXTURE CONNECTION SCHEDULE. 5. LOCATE CLEAN -OUTS WHERE SHOWN ON PLANS OR YE:2UIRED PER THE UNIFORM PLUMBINE CODE 6. ALL WATER ROUGf•± -INS TO BE TERMINATED WI n+ SI ,,T - OFF VALVES BEFORE CONNECTION T .: EQUIPMENT AND FIXTURES. ? PURGE AND SrtKILiZE ALL WATER LINES PER CODE BEFORE CONNECTION TC r ' ' XTURES AND L' UIPMENT. 8. ALL SOIL AND WASTE LINES .ARE SHOWN AT POINT OF CONNECTION AT FIXTURE. GI. EXAMINE CONNECTION DIAGRAMS BEFORE PROGEED'NG WITH ANY ROUGH -IN 'WORK. 10. ALL BELOW SLAB PLUMBING SHALL BE A MINIMUM Or 2 ' . RECEI4ED CITE` ,fir T' IKWILA MAY 1 ?GC? PERMIT EN 1F ~ a A5 NOTED ' RST A.J. DAll'. 4 -26-02 [pow* lev+es, L SPECIFICATIONS 4 EQUIPMENT SCHEDULE OIRAMNS tweet M -4