HomeMy WebLinkAboutPermit M02-107 - HEWES RESIDENCEHEWES RESIDENCE 4033 SOUTH 150T" ST �w 6 CO W0 �? (A v Z W Lu EXPIRED oN. 0H =W 10 -14 -03 Ip WZ O z M02 -107 �4_W.. ..., r. i ...,.... 4 S LY.�S Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: doc: Mech City of''ukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0041000567 4033 S 150 ST TUKW HEWES RESIDENCE 4033 S 150 STREET, TUKWILA, WA HEWES STEVE 14720 26 LN S, SEA TAC, WA STEVE HEWES 14710 26 LN S, SEATAC WA Contractor: Name: OWNER AFFIDAVIT Address: Contractor License No: DESCRIPTION OF WORK: INSTALL NEW FURNACE AND WATER HEATER AND MAIN DUCT TO EXISTING RETURN AIR AND SUPPLY DUCTS. Value of Construction: $1,800.00 Fees Collected: Type of Fire Protection: Uniform Mechnical Code Edition: Permit Center Authorized Signature: 1< I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construry` .r the p= yformance of work. I am authorized to sign and obtain this mechanical permit. I�� Oier°7 Signature: -� i ' � ' Date: Print Name: t tC R (A( A l MECHANICAL PERMIT MO2 -107 Permit Number: Issue Date: Permit Expires On: Expiration Date: Phone: Phone: 206 - 618 -2778 Phone: MO2 -107 06/06/2002 12/03/2002 Date: - 0 ? $61.19 1997 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 06 -06 -2002 Parcel No.: 0041000567 Address: 4033 S 150 ST TUKW Suite No: Tenant: HEWES RESIDENCE 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296 - 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206 -835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: Fuel burning appliances may not be installed in sleeping rooms, U.M.C. 304.5. 11: Appliances which generate flame, spark or glowing ignition, shall be elevated 18 inches above the floor (U.M.C. 303.1.3.). 12: Water heater shall be anchored to resist earthquake (U.P.C. 510.5). I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construct,_ or he performance of work. Signature: Print Name: doc: Conditions City of ' tukwi1a Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS MO2 -107 Permit Number: MO2 -107 Status: ISSUED Applied Date: 05/21/2002 Issue Date: 06/06/2002 Date: Printed: 06 -06 -2002 it W � UO ND W CO Li. W } g J u_ a Z Z 0 W W. D. .O — 0 I— W w : H 0: O iti Z. O Project Name/Tenant: 1 C L Value of Megchanic quipment: 1 600,0c Site Address : 40 '3 S / / 3 C ity Stat Zip: Tax Parcel Number: Date: Property Owner: S H r , Q ,)/ 02 Print name: g - 6- f Phone: (, ) 6 . /j/ ,.. 72 c Street Address: /2 / 7/ 6 , z A ' J E City State/Zip: Fax #: ( ) ) Contractor: � /1 f 47/6 /O Tc9 I o' ■ 6 City/State/Zip: Phone: ( ),! Street Address:� 1 City State/Zip: Fax #: ( Contact Person: l i / Phone: c2,06) c2,06) �) G/8 .? 778 Street Address: City State/Zip: Fax #: ( ) ''BUILDING O 1F HORI - _AGENT: ' ter/ /�� lJi�NA, Date: 5 ,)/ 02 Print name: g - 6- f 3 Phone: 0,0 6 ) Fax #: ( ) Address: f 47/6 /O Tc9 I o' ■ 6 City/State/Zip: ),! 7 / 1 11/2/99 niech pern,U.doc CITY OF " IKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 R STAI I USE ONLY Project Number. Permit Number. Nlv2 -�v7 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. , MECHANICAL' PERMIT' REVIEW AN AN &APOROVAt REQUESTED (TO REFILLED OUTiBYAPPLICANT) Description of work to be done (please be specific): 0(}67e e_) a/4P E /)ci e r 7 - o a /S /A) "arc/ Ste, Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor • Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: .f. oot Date application expires: / —� / — v im Application taken by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. ,■OTE: Waterheaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Payee: SBH ENTERPRISES TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt Current Pmts Amount Payment Check 2318 MECHANICAL - RES PLAN CHECK - RES Type City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 0041000567 Permit Number: MO2 -107 Address: 4033 S 150 ST TUKW Status: APPROVED Suite No: Applied Date: 05/21/2002 Applicant: HEWES RESIDENCE Issue Date: Receipt No.: R020000752 Payment Amount: 61.19 Initials: KAS Payment Date: 06/06/2002 01:25 PM User ID: 1684 Balance: $0.00 Method Description 61.19 Description Account Code 000/322.100 48.95 000/345.830 12.24 Total: 61.19 Printed: 06 -06 -2002 Project: N eit12 S Type of Inset Addres • 1 4033 S. 150 St • Date called: d I -02 eeclal instructions: rucctiions: +111/1e. 1 Le 4 .e_ C eat. lid ila 17- 0 Date wanted: ( a .m Req ster a-e :v e - e we 5 4hoa:o6_to i2- 2 -7 7 $ INSPECTION NO. `. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 0 Approved per applicable codes. rA zivXzcp ':.4e•. SIG`.+�th'4;:D.- `� .�.y$'hCY:7.�:i• INSPECTION RECORD Retain a copy with permit M 0a -; 1 i PERMIT NO. (206)431 -3670 COMMENTS: 5 4, -, (. 4, /` cr v l 1 � kia I 3 �I c�lrert�L /�/ //�-� C j iz-ze Corrections required prior to approval. 0 S4 REINSPECTIOWFEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt N'b: Date: Z c4 2 U W0 Zo W uj 2 p 0I- W I 1- L - 1 - - O . O Project:. Type of Inspection: Address: L i 07Y 745-Date 5 /5b called: ' Special instructions: Date wanted: � Requester: Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila; WA 9818 COMMENTS: 7- ,/ .) j r . /4 4.-r--A•re l , I-4, )7/4 ti �'t .Y,t /.. /aA `/ Date: 7 0 .Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -367 Corrections required prior to approval. E I $47.00 REINSPECTIONtE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: COMMENTS: / 1 "2€'e�- -- "ZC '? t l�GjdL -�' - 41-1 2-- 4Du tie_ c���'4",.!' c-4 44, ,?e Date called: 7 -1 -v «, `/4 6 ye, f3A3 ,€ ii, ( fr i., . , l z f � -, ' -t ;'/ c 4 - . '5 L/'" td -.." a-‘ ri_yetl.4 70 4 (a - 114, I-- i - cola/ teo ! / s o z, { /t-1C9 - fll,5 -) 7 fr1 ', . , p p , 1-7 477g/ /' i ,/ e -, w,by„ -,-. // ffA-ui .1,1 t . A tso. 1_,. cl� / ,I1 ���,r" - I - -- 5 6 _4/ di. „_/. , . li, {,e7,/,,,/ 5. ,«e_4 Inspector: `�/ _/” l'!A .. A !' !/ /J 4.i Date: 7---2-677 Project: ;, ;;_ ::: i) R .; " : Type,of Inspection: . lvnr, ,1A:el Address %' : ' = ,. ' 41,3.3. .. ich st Date called: 7 -1 -v Special inttFuctions: ,(( Date wanted: 1 -1--o2. a.m. p.m. Requester: - Phone: a2O lo/ $ - .2178 ._ 'i3!..n .... :,:;e:.; zip; •:�!tµii,'.iit :f•::,:� / INSPECTION RECORD Retain a copy with permit INSPECT! • NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila,AA 98188 Mtn-- X PERMIT NO (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. 0 $47.00 REINSPECTICYN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: 1 „ 0 0 to W w J N W u - P.' a W U � N 0 I— W W U. . . z z eating &Cooling ERN QUIRED FO ECHANICAL LECTRICAIQ LUMBING AS PIPING OF TUKWI I understand that the Plan ChetirjpRaSaMT subject to errors and omissions an approva o ' does not authorize the vi ! . 9 RofHE opted code or ordinance. Receipt ot ctor's copy of approved plerttlfittia By Date Permit No. IT MC LA UP SION FILE COPY (0 g 1 id D2 MY OF TUKVALX PR ROVED ) EL PG8UAA JUN - 201112. LOW FURNACE i tk;; Piii C,'131tr3�lC'a d {LrY'�� © WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or Toss of life. • — Do not store or use gasoline or other flammable va- pors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the as supplier's instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qual- ified installer, service agency or the gas supplier. G Furnace •E r ,i dr GAS -FIRE I ' STALLER: AL MUST BE LEFT WITH THE EQUIPMENT USER. Do not use this furnace if any part has been under water. Immediately call a qualified service technician to inspect the furnace and to replace any part of the control system and gas control which has been under water. ' ORMATION MANUAL PERATION AND " NCE OF YOUR NEW FURNACE $ O Pal! D pp o MODEL PG8DAA DOWNFLOW /HORIZONTAL FURNACE 0 CITY OF TOM / 11 4 MAY 2 3 2002 PERMIT CENTEF, UNIT SIZE A D E VENT CONN SHIP. WT (LB) 024045 14 -3/16 12 -9/16 12 -11/16 4 122 036045 14 -3/16 12 -9/16 12 -11/16 4 124 024065 14 -3/16 12 -9/16 12 -11/16 4 132 036065 14 -3/16 12 -9/16 12-11/16 4 134 042091 17 -1/2 15 -7/8 16 4 150 048091 21 19 -3/8 19 -1/2 4 154 036111 17 -1/2 15 -7/8 16 4 160 048111 21 19 -3/8 19-1/2 4 166 066111 24 -1/2 22 -7/8 23 4 GUY Y OF TUKWI A 184 048135 21 19 -3/8 19 -1/2 5' APPROVED 5' 178 194 060135 24 -1/2 22 -7/8 23 060155 24-1/2 22 -7/8 23 5* film - ; f n n r 204 3 19 7," Oval collar 28 12" VENT CONN 1/2-IN. DIA HOLE POWER ENTRY 7, ,t -IN. DIA ACCESSORY 1 3 /4- IN. DIA HOLE GAS ENTRY 1/2-IN. DIA HOLE THERMOSTAT WIRE ENTRY SIDE INLET 1 -6— 24 5 /16" AIR INLET • d I " I� 2 VW " r 125 1 16" 4 2 39" i D 11 A 1 .r 15 443" 0 O O 0 0 0 0 0 O 0 O 0 o_ O 0 o O ° O O O ° O I1 6 " �� E k 221.16- NOTES: 1. Two additional Dili -in. dia holes are located in the top plate. 2. Minimum return -air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturers recommendations for equivalent diameters. a. For 800 CFM- 16 -in. round or 14 x 12 -in. rectangle. b. For 1200 CFM- 20 -in. round or 14 x 19 -in. rectangle. c. For 1600 CFM- 22 -in. round or 14 x 23 -In. rectangle. d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side Inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. -*Fig. 2— Dimensional Drawing Table 1— Dimensions (In.) INTRODUCTION ivt; 1 E -4 The model PG8UAA, Series C and D Furnace is available in sizes 45,000 through 155,000 Btuh rn i g ��Di-vrttC}iJ The design of the upflow gas -fired furnace is A.G.A. /C.G.A. certified for natural and propane gases and for installation on noncombustible flooring. The furnace is factory- shipped for use with natural gas. The manufacturer's accessory gas conversion kit is required to convert furnace for use with propane gas. These furnaces SHALL NOT be installed directly on carpeting, tile, or any other combustible material other than wood flooring. This furnace is for installation in alcoves, attics, crawlspaces, basement~, closets, or utility rooms. The design of this furnace line is not A.G.A. /C.G.A. certified for installation in mobile homes, recreation vehicles, or outdoors. Before installing the furnace, refer to the current edition of the NFGC and the NFPA 90B. Canadian installations must be installed in accordance with NSCNGPIC and all authorities having jurisdiction. For a copy of the NFGC NFPA54/Z223.1, contact International Approval Services U.S. Inc., 8501 E. Pleasant Valley Road, Cleveland, OH 44131 or National Fire Protection Association Inc., Batterymarch Park, Quincy, MA 02269. For a copy of NFPA 90B, contact National Fire Protection Association Inc., Batterymarch Park, Quincy, MA 02269. Before installing the furnace in Canada, refer to the current edition of the NSCNGPIC. Contact Standards Department of Canadian Gas Association, 55 Scarsdale Road, Don Mills, Ontario, Canada M3B 2R3. —3— 5 1s 2 11A 2 " f 2 TYP j " e � �F� Q AIRFLOW 19 OUTLET 7 2-IN. DIA POWER ENTRY 1 1/2-IN. DIA Q R.H. GAS ENTRY 7 b -IN. DIA ACCESSORY 1/2-1N. WIRE ENTRY SIDE INLET Grp 23 SIDE RETURN DUCT LOCATION LUJ 1 RECEIVED OF TUKWILA MAY 2 3 2002 PERMIT CENTER A00210 Project Name: H I Q. Li) LC Address: ki0 3 3 S. ‘50 Si. Residential Building Permit Number: 1. Prescriptive Option W.S.E.C. Chapter 6, (check building permit option used): ❑ I. ❑ II ❑ ill. ❑ iv. ❑ v. ❑ vi. ❑ vu. ❑ vin. 2. House Square Footage (HSqFt) l d 3. Heating System installed, (check system type below): ❑ a. Electric Resistance /21 BTU /h per sq. ft. r IT' OF TUK r3 b. Electric (forced air) /24 BTU /h per sq. ft. trc. Other Fue - gas eat pump) /27 BTU /h per sq. ft. MAY 2 3 ?002 4. Equipment: a. Make �a�• Al— b. Model c. Size in BTU's Ss ooa 5. Calculation /(HSqFt) (see line 2 above) BTU /h X (see line 3 a, b, or c above) BTU Equipment Maximum Size CITY Q,f TUKWILA Permit C. .'ter 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 Prescriptive Heating System Sizing for Single Family Homes - New Construction Washington State Energy Code Chapter 9, Climate Zone 1 PERMIT APPLICATION #: pt oz_ /0 7 H -6 Applicant's Signature: I Date: CITY if TUKWILA APPP010 7/9/96 ! " `Ovecl ©v‘ C0(..\ CL) ot,,4 0 r■ S JUN - 5 2i1( }Z h j UtLU it,'TFt l ► G DTtiF! Istal January 6, 2003 Mr. Steve Hewes 14710 26 Ln S SeaTac, WA 98168 Dear Permit Holder: City of Tukwila RE: Permit Application No. MO2 -107 Location: Hewes Residence 4033 S 150 St In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: This inspection is intended to determine if substantial work has been accomplished permit or last inspection; or if the project should be considered abandoned. The Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to February 16, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, K G. Kathryn A. Stetson Permit Technician Xc: Permit File No.MO2 -107 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98/88 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 Department of Community Development Steve Lancaster, Director •Call the City Of Tukwila Permit Center at (206) 431 -3670 to scheduled inspection WA Steven M. Mullet, Mayor arrange for the next since issuance of the May 29, 2002 Steve Hewes 14710 26 Lane S Sea Tac, WA 98188 w o vow N LL w 0 2 J This letter is to inform you that your permit application received at the City of Tukwila Permit Center on O May 21 2002, is determined to be incomplete. Before your permit application can begin the plan review w w process the following items need to be addressed. 2 D O N Building Division Ken Nelsen, Sr. Plans Examiner 0 H 206/431 -3677 v . • H ui N O RE: Letter of Incomplete Application #1 Development Permit Application Number MO2 -107 Hewes Residence 4033 S 150 St Dear Mr. Hewes: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 1. Please provide a floor plan indicating the location of the new furnace. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Sheet' must accompany every resubmittal. 1 have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3684. Sincerely, 4tAATU iefiCitieTht- Kathryn A. Stetson Permit Technician encl File: Permit File No. MO2 -107 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98/88 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: MO2 -107 PROJECT NAME: HEWES RESIDENCE SITE ADDRESS: 4033 SOUTH 150 STREET Original Plan Submittal Response to Correction Letter # DATE: 5 -31 -02 Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMEENN Buildi D [, Division Public�orks (1 �� ❑ Complete Please Route TOES /THURS ROUTING: Documents/routing slip.doc 2-28-02 PLAN REVIMRSDfNVG SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete REVIEWER'S INITIALS: 1:.►:1`�`� f C O O RD ❑ Planning Division ❑ Permit Coordinator DUE DATE: 6-4-02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required ❑ No further Review Required DUE DATE: 7 -02 -02 REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: re w 00 co o u w w • 0 u _ = F W Z � 1- 0 Z 1— w U � O � 1— W W H- 1'O .. Z O~ Z ACTIVITY NUMBER: MO2 -107 PROJECT NAME: HEWES RESIDENCE SITE ADDRESS: 4033 SOUTH 150 STREET DATE: 5 -23 -02 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division d Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: Permit Center Use. Only INCOMPLETE LETTER MAILED: 5'2 6 1-01. LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: PERMIT COORD COP PLAN REVIEW /ROUTING SLIP Incomplete Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 10 Fire Pr vention Planning Division ❑ Structural ❑ Permit Coordinator Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: W, :MIT COORD C DUE DATE: 5-28-02 DUE DATE: 6-25 -02 Not Applicable ❑ DATE: r4 2 J U U N LU U4_ H CO LL W l � 0 u. (i) d Z Z0 11J uj U w ON 0 I— W W .Z O~ Z ■ City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6 / 3 //" v Plan Check/Permit Number: MO2-107 ® Response to Incomplete Letter # _1_ [] Response to Correction Letter # • Revision # after Permit is Issued Project Name: Hewes Residence Project Address: 4033 S 150 St. Contact Person: '7E✓& Flew.64 Phone Number: ;,),0 G/' .2"77" Summary of Revision: fflea . - � ►� - d� 5� 0°°(? p Jct v, Ir�.2 Occ to.� a 110 Gc a,-. (L / Se-ehyk► / /4,00 76'4 V---KP *// Gn, > '4, rn 7 ctLi-12- ,\3V Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Ei Entered in Sierra on 1 RECEIVED CITY OF TUKWILA PERMIT CENTER 05/29/02 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON ) COUNTY OF KING AFFCONT 1/13/00 CITY OF TI 'CWILA Permit Cente, 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 ss. , states as follows: APPLICANT titO Signed and sworn to before me this btti day of June residing at i< County. Name as commissioned: All c e 4 Deac y My commission expires: 6 " ) H -4 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. /-- , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work A. O\ � C ' ' t1 • P � 1'I : : 0 4 IAOTAR PUBUC ; • �7 A � q • 6 -0� &� ( �tl � op NOTARY PUBLIC in a`fid for the State of Washington, , 20 0 2 . n.w...nw.1uw.r.wnm.*PPO .1..11eWeCoureVit.P014.1. rrn:wrthenNS..1 . 18.27.090 Exemptions. This chapter shall not apply to: 1. An authorized representative of the united States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT 1/13/00 of the operation is made into contracts of amounts Tess than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work.