Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M02-118 - LOWER JUNCTION - LOT 6
LOWER JUNCTION LOT 6 5436 S 150 ST M02 -118 w 00 cow w0 g a' w O 11.1 uj p: O co C ww U H Z w co: O Parcel No.: 8733000065 Address: 5436 S 150 ST TUKW Suite No: Tenant: Name: LOWER JUNCTION - LOT 6 Address: 5436 S 150TH STREET, TUKWILA, WA Owner: Name: SCHERLER ARNOLD E II Address: 5439 S 150TH ST, SEATTLE WA Contact Person: Name: DON TRYON Address: 14420 SE 84TH STREET, NEWCASTLE, WA Contractor: Name: TRYON CONCEPTS LLC Address: PO BOX 146, RENTON, WA Contractor License No: TRYONCL013DH DESCRIPTION OF WORK: INSTALL NEW FURNACE AND WATER HEATER Value of Construction: Type of Fire Protection: Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 $4,000.00 N/A �o •v / / MECHANICAL PERMIT Permit Number: MO2 -118 Issue Date: 01/06/2003 Permit Expires On: 07/05/2003 Phone: Phone: 425 255 -6518 Phone: 425 - 255 -6518 Expiration Date: 02/11/2003 Fees Collected: Uniform Mechnical Code Edition: Date: /`l. -13 Date: ( -6 - °3 $ 70.25 1997 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -118 Printed: 01 -06 -2003 Parcel No.: 8733000065 Address: 5436 S 150 ST TUKW Suite No: Tenant: LOWER JUNCTION - LOT 6 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296 - 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Manufacturers installation instructions required on site for the building inspectors review. 9: Water heater shall be anchored to resist earthquake (U.P.C. 510.5). I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Print Name: ( a /) �2 4D /1 doc: Conditions PERMIT CONDITIONS MO2 -118 Permit Number: MO2 -118 Status: ISSUED Applied Date: 06/10/2002 Issue Date: 01/06/2003 Date: l G -o r Printed: 01 -06 -2003 Project Nam eR J cJ A CT /d it) GD t 6 Value of M fhan� cal Equipment: Site Address : 5436 S, tSo *4 iO tii'cvr (c 4)4 Cliv Sta Z ip: 9"rtr Tax P rcel N umber: 3,� oo — 4665' Property Owne : Phone: (206) 2 4 6 _ 26 ( 9 Street Address: City State/Zip: 54.79 5 . (so s 747e t(4 e...b 9?(d? Fax II: ( ) Contractor: �g Phone: ( ,R 2 S - 09 t7 Street Address: D p / /2022 if AP Q, /UM etteaNG w4 • ityStat Ziy: '- Fax It: (4 47 ^( 4 Contact Person: City / State/Zip: Phone: Street Address: City State /Zip: /44ae S 14 Sf N o s -(-! e Wri 'foss Fax it: ) , . 9� Zfi 2 s S ;BUILDINICOWNER OR AUTHORIZEDAGENTe- i vs „, Date: Signature: � Print name 940 N Phone: (11 1 255 4 6 57 k - 4 — Fax It: ) 2 . 55 we(' Address: 9 City / State/Zip: CITY OF T ~ ''CWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 STAFF SE ONLY Project Number. Permit Number. / //c Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUTBYAPPLICANT) Description of work to be done (please e s ,cific)• ��25 ,i [U r& 4C Q u a r /-" Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: c Date application expires: —e ms. Application taken by: (initials) 11/2/99 web perniil.doc Z ~ W U CO 0 w= t— w a rt (n J ▪ a � Z = Z I � • 0 0 O C 0 F- W W I I- LI- .. W Z 0 0 Z ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal 11/2/99 ,nixcpmr,doc Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I. Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Project: L ��t u( r' :�c;1�1c i �O T of in ction: //'1 Addr ss: 54 3 s lo '1- Date Cal et d: 7 l 3 Special Instructions: Date Wanted✓j J f v 03 a.m. Requester /)D ' Phone Kgo ^ — g v M g INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: rhAi Coley, �e Inspector. :m iL9 Date: — 7 -- 10 - 03 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: I Low( r (iune-hon- ZS 1, Type of ispection:i Lio c r Address: 5 S )5 3 - 1 --- Date Called: ( / L / 110103 Special Instructions: Date Wanted: i 9 11 I C3 . . p.m. RequesteF„, t-ior Phone No: 355 - 5VOT • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 -- -PP roved per applicable codes. V4 COMMENTS: Inspec oLL 1 HS' El Corrections required prior to approval. Date: 1 4 -00 /b REINSPECTION F E REQUIRED. Pri )r to inspection, fee must be t 6300 SouthcenterBlvd., Suite 100. Call to schedule reinspection. Rec 'Date: 9 Project: 11X4 J 1J i ,1C1) 1 217 - L Type o nspectio : t (Q Z)( - '1 �7 d ress: 1 U __ j . aped: D SpecialZt Date Wanted: ( m i�( ! / P.m. Requester: 'Mc T Ph ne \ p LP I ..5 C)%19O INSPEC ION NO. Inspector: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 D Approved per applicable codes. :aror r r.a � ".:� n ii . !t 3 P1 �Q .t t:+l� .n' i� , .:f sssr y . t':; PERM )431 -3670 _ Corrections required prior to approval. COMMENTS: 1.) Sf'c \ tt U,($4C I r red U 1 t(c . rAtArk si-c L Y\ P, 4 (' C-1 �t ►" C� V C� ocf _I \ ocr,41. A ci4 } • V\4 Date: �1 _ 9- 0 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project Name: Site Address: 5/31/02 CITY OF TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 Residential Heating and Ventilation Compliance Form (Complete Sections I and II for Group R Occupancies 4 Stories or Less) MECHANICAL PERMIT APPLICATION NO.: 140Z- ItS aa BUILDING PERMIT APPLICATION NO.: � O2." %SS 7 C, (S'o s7 ^eAC d, r!� FILE COPY I. WASHINGTON STATE ENERGY CODE HEATING DESIGN METHOD (select A, B or C belowtS1y OF TUYilri..A APPROVED A. ❑ System Analysis - W.S.E.C. Chapter 4 (submit documentation) B. ❑ Component Performance Approach - W.S.E.C. Chapter 5 (submit documentation) DEC 2 3 2002 C. IN Prescriptive Option - W.S.E.C. Chapter 6 (for prescriptive, complete the following): j ; ri:.; i Gi 1. House Square Footage (heated space): -- caD -° --- 2. Heating System Installed, (check system type below): a. ❑ Electric Resistance /21 BTU /h per sq ft b. ❑ Electric (forced air) /24 BTU /h per sq ft c. ® Other Fuels (gas, heat pump) /27 BTU /h per sq ft 3. Calculation /(House Sq Ft): (see item #1 above) BTU /h X z7 (see item #2 a, b or c above) _ �i 3 7Zo Maximum BTU of Heating System II. WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (select A or B below): RECEIVED CITY OF TUKWILA JUN 1 0 2002 PERMIT CENTER A. ❑ Ventilation by Performance or Design Method - W.S.V.I.A.Q. Section 302 (submit documentation). B. ❑ Prescriptive Ventilation Options - W.S.V.I.A.Q. Section 303 (select one of the following): 1. ® Ventilation using Exhaust Fans (Section 303.4.1.) ❑ Exception for outdoor air inlets - Forced air heating system w /interior doors undercut 1 /2" 2. ® Ventilation integrated with Forced Air System (Section 303.4.2.) 3. ❑ Ventilation using Supply Fan (Section 303.4.3.) 4. ❑ Ventilation using Heat Recovery System (Section 303.4.4.) Prescriptive Minimum /Maximum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form). 1. House Square Footage: Z. 1 7 ( G 2. House Number of Bedrooms: 3. Required Outdoor Air Table 3 -2: Minimum - / cfm Maximum - ! S° cfm Floor's f 1 Area, 2 • g jm Bedrooms .. r • f .:, 3 4 5 6 7 8 4 inch Min Max Min Max Min Max Min Max Min Max Min Max Min Max < 500 50 75 65 98 80 120 95 143 110 165 125 188 140 210 :: X501=1000 :u. .' :133 ''; ' i70 " '' ``,105:.' - : 85 '' i',128 '. ::100 :..150 :' :: 1 ;173'. .130 :. :195'. ;145: , 2.18 - 1001 - 1500 60 90 75 113 90 135 105 158 120 180 135 203 150 225 +:1501-2000 >> : :':65; : 98= 80 •? • . :120`.:' '.95;' .143: '110 i '.165''; '125 'A 88.'i :.140, s • , 210'', - 155: ' 2001 - 2500 70 105 85 128 100 150 115 173 130 195 145 218 160 240 ;v 2501- 300($, .. ' „i1:13:!. 90f :'' 035:: ::105. 158 ;. 120;' :180 ?035 x:203 .::; No Limit ';225 165.: '.'248:: 3001 - 3500 80 120 95 143 110 165 125 188 140 210 155 233 170 255 °.!' ;',3501 - 4000' .” ' 85; : ' 128 ' ,,.100' 150 ": '- 115:: - ':130 ==195: ;145: :, 218: 0:60 • : 240 ':;175 263, =' 4001 -5000 95 143 110 165 125 188 140 210 155 233 170 255 185 278 `5001= 6000:` : ;:105 - ;158 :120;. `.180: '.135'.. i : 203 ' 150 ; 225 ' °;165 , :248:..: 180'' • :270': -1951 ::'293` 6001 -7000 115 173 130 195 145 218 160 240 175 263 190 285 205 308 °z- `•700,1= 8000: 6: ..125'` :;188.:..:140 :..: ".:.155: .=233 :. :170::_ 255: - ' :185::". `278 ': 200 •: = : '300'` ' >.215 - 323. 8001 - 9000 135 203 150 225 165 248 180 270 195 293 210 315 225 338 :'9000'i s :;145. ::2113" ':160` - .:240" 175. ' '`190. 285`; - 205 308 '. 220 . ; ;,330:; .235:: '..353' 5/31102 TABLE 3 -2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) For residences that exceed 8 bedrooms, inc ease the minimum requirement listed fo 8 bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 times the minimum. TABLE 3 -3 PRESCRIPTIVE EXHAUST DUCT SIZING 1. For each additional elbow subtract 10 feet from length. 2. Flex ducts of this diameter are not permitted with fans of this size. ... .. . <.,.r.'a.SfxY. <.rv1� 'a. kLrunt•3':.r.Yr �Nh i -iiu;tis , "k 14 ''pne •.� 4 51 !�:lfip kFt z z re w jU 00 CO 0 H w � N O W Z1.— t— 0 W F— W D ON C3 W W O W Z U= O~ Z Fan Tested CFM fp 0.25" W.G. Minimum Flex Diameter Maximum Length Feet Minimum Smooth Diameter Maximum Length Feet Maximum Elbows' 50 4 inch 25 4 inch 70 3 .``:_... ,'i50' " . ti .... • . , :,5 mcht `: . ' ,r90 ',• inch . { • .?100' . r , . ... • 3 50 6 inch No Limit 6 inch No Limit 3 :` :j. -. 80;: i . ''' inch . 1 ,'NA .4'inch. '20 80 5 inch 15 5 inch 100 3 ,. ; :',80; ,:, ::., ',. =6 inch`... , , , , :; =-90r ;:' �, ; :. • inch:. ....:: • •.:.:. No Limit` '., ... : • .. 3 . 100 5 inch' NA 5 inch 50 3 . . 4 '000 V 6' inch': , . "45' - 6 `; ' — .No‘Limit, 3 125 6 inch 15 6 inch No Limit 3 125: ; ... .. ', :,7-inch ;.• 70 7 -inch :No Limmit 3 5/31102 TABLE 3 -2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) For residences that exceed 8 bedrooms, inc ease the minimum requirement listed fo 8 bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 times the minimum. TABLE 3 -3 PRESCRIPTIVE EXHAUST DUCT SIZING 1. For each additional elbow subtract 10 feet from length. 2. Flex ducts of this diameter are not permitted with fans of this size. ... .. . <.,.r.'a.SfxY. <.rv1� 'a. kLrunt•3':.r.Yr �Nh i -iiu;tis , "k 14 ''pne •.� 4 51 !�:lfip kFt z z re w jU 00 CO 0 H w � N O W Z1.— t— 0 W F— W D ON C3 W W O W Z U= O~ Z Project Name: CITY OF TI;I;W'IiA Len de r dv a c -1 • APPROVED Address: 543 6 5, r5o sr veKtvh c4 DEC 2 3 2002 Residential Building Permit Number: t: +Jici) D02."' I�S CI5 ?:f ilA w'.. !' 7!4 A.'%h r 1. Prescriptive Option W.S.E.C. Chapter 6, (check building permit option used): ❑ I. ❑ II ❑ III. ❑ IV. ❑ V. ❑ vi. ❑ VII. ❑ VIII. 2. House Square Footage (HSqFt) Z 3 C, O 3. Heating System installed, (check system type below): RECEIVED CITY OF TUKWILA ❑ a. Electric Resistance /21 BTU /h per sq. ft. JUN 1. 0 2002 ❑ b. Electric (forced air) /24 BTU /h per sq. ft. PERMIT CENTER c. Other Fuels (gas, heat pump) /27 BTU /h per sq. ft. 4. Equipment: saw (Oa 5 5 o gcP ° r t a. Make rehfPF /t4 b. Model D7S 4'C R c. Size in BTU's loo ° c d 5. Calculation /(HSqFt) z 3600 (see line 2 above) BTU /h X 7-1 (see line 3 a, b, or c above) 63120 BTU Equipment Maximum Size 7/9/96 CITY (iF TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 Prescriptive Heating System Sizing for Single Family Homes - New Construction Washington State Energy Code Chapter 9, Climate Zone 1 PERMIT APPLICATION #: 1 g FILE COPY H -6 . _....f....�r ,. nnnrr 'IIs ore Applicant's Signature: —00x fiff" Date: t GAS FURNACES RGLH- SERIES Models with Input Rates from 45,000 to 150,000 BTU/HR [13 to 44 kW] (U.S. & Canadian Models) ENERGUIDE Yowl .. I..r.l.., • AFDE room END in m n a EFFICIENCY HATING CERTIFIED ama FORM NO. G11 -449 REV. 2 Supersedes Form No. G11 -449 Rev. 1 CRITERION® II 78 % -80% A. F. U. E. DOWNFLOW GAS FURNACES DIY OF Tiir,1 i • `._ , 2 3 t The Rheem • Criterion® II line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by the American Gas Associa- tion. Canadian models are certified by the Canadian Gas Association. Features • Patented Turbulex• heat exchanger, constructed of both stainless and aluminized steel for the maximum in corro- sion resistance. • Low profile "34 inch" [864 mm] design is lighter and easier to handle, and leaves room for optional equipment. • Both standing pilot and hot surface ignition models available. • Left or right side gas and electric inlet connections with quick, simple change. • Hot surface ignition models feature a new integrated board with humidifier and electronic air cleaner hookups. • Insulated blower compartment, a slow -open gas valve and a specially designed draft inducer motor make it one of the quietest furnaces on the market today. • Pre -paint galvanized steel cabinet. • Grab -holes in doors to aid in easy door removal and replacement. A variety of cooling coils and plenums designed to use with Rheem Criterion II gas furnaces are available as optional accessories. tA.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy lest procedures. RECEIVED CITY OF TUKWILA JUN 1 0 2002 PERMIT CENTER tIILv.tI8 � Draft Inducer Motor Hot Surface Ignitor with Remote Sense (Hot Surface Ignition Models) STANDARD EQUIPMENT RHEEM Chi i ERION It 78 -80% DOWNFLOW GAS FURNACE Pilot Assembly (Standing Pilot Models) Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut -oft valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi - speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; N.S.I. only twinning options, standing pilot models may not be twinned; fused transformer (secondary), 3rd speed option for continuous lan; common heat/cool terminal for H.S.I. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local Installer. Molded Permanent Filter Blower and Control Box Integrated Furnace Control In -Shot Burners and Gas Valve Turbulex'Heat Exchanger All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519 -53 for Canadian models. NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition is 100% lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES ��, *� ; r,;�, tis ; . X < �' a �, s • , ` I w � . ��� � s M B ES S 4 ' ) ;;c ,. t h (.w : '? .0.4,y: J` 045: USR 4M USR.. 04EAUS z MIA ti 1[USA O„E`AUSA = - 50AUER :' 0515 UER 06' EA1 ER 0511AUER'' 06 OK, .A_ . H'067AUEq t O 6MAUER ' 06EAUER�% ' -/06NAUER� ,t k057AUEA. '` 06EAU Ell ' 075 UER 1 7 UER 07EUER NAbE 0 5" �.. EA 0� U ' A75AMGR'' ,�pp �MAMGR . v(`O EAMGR *AMR ago EAM G�1 .7k, 'l " 100AUER '1, , 10MAUEjt f o AMER i ; 1ON AME. -' F r:ti 100A 01► = 1� lOEA '° <:. OOG JR ; 1 r ' 10E11R '°'' 6EGRlfi;� N ;; I B F ., 4 ; va t � � :. _ t' 6 � OEStI� ,' ;"'125ARJR • 2MAfiJR . 2EARJR 2NARJRt, 2L $SARJA '�2EA[t;lll'� ;s % ' 15MARJ�i+� s 15EARJF w " 15NARJ ' - 15011RJA� �'15E11FgA0 Input- BTU /Hr [kW] 0 45,000 [13] 50,000 [15] 67,500 [19.8] 75,000.[22]' 75,000 [22] 100,000 [29.3] 100,000 [29.3] 125,000 (36.61 150,000 [44] Heating Capacity BTU /Hr [kW] O 36,000 [11] 41,000 [12] 54,000 [16] 60,000,[1;01. 60,500 [18J 80,000 [23] 81,000 [24] 99,000 [29] 120,000 [35] High Altitude Input [kW] 40,500 [11.9] 45,000 [13] 60,800 [17.8] 67,500110.8] 67,500 [19.8] 90,000 [26.4] 90,000 [26.4] 112,500 [33] 135,000 [39.6] High Altitude Output Capacity [kW] 32,900 [9.6] 36,500 [10.7) 49,000 [14.4) 53,500117] 54,000 [15.8] 72,000 [21.1] 72,500 [21.2] 89,000 126.11 107,500 [31.5] Heat Ext. Static Pressure [kPa] .10 [.025] ,.10 [025] .12 1.029] .12 (.02 ,I .12 [.029] .15 1.037] .15 (.037] .20 [.05) .20 1.051 11x6 =10'AU Blower (D x W) (mm] 1 1 x 6 [279 x 152] 1 1 x 6 [279 x 152] 1 1 x 6 [279 x 152] 1 1 6 [279 1 2] 1 1 x 7 [279 x 178] [279 x 152] 11 x 7 = 10'AM 1 1 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 10 [279 x 254] [279 x 178 Motor H.P. [W]- Speeds [WI- /2 -4 -PSC '/2 -4 -PSC 1 /2 -4 -PSC 1 /2 -4 PSC 3 /4 -4 -PSC l/2 -4 -PSC 3 /4 -4 -PSC 3 /4 -4 -PSC 3 /4 -4 -PSC PSC Type [373] [373] [373] [373] -; [559) [373] [559] [559] 1559] Motor Full Load Amps 7.1 6.8 7.1 VII' : 9.5 7.1 9.5 9.5 9.5 Heating Speed MED -LOW MED -LOW MED -HIGH MED. H MED -LOW MED -HIGH MED -LOW MED -LOW MED -LOW Cooling Speed HIGH HIGH HIGH HIG L_ MED -HIGH HIGH MED -HIGH MED -HIGH MED -HIGH Cooling CFM @ .5' [kPa] E.S.P. 1200 1200 1200 1200 ; . 1600 1200 2000 2000 2000 (Nominal) [Us] [566] [566] [566] [506 , [755] [566] [944] [944] [944] Rated E.S.P. (In. W.C.) [kPa] .50 (.12] .50 [.12] .50 (.12] .50 [.12] - .50 [.12] .50 [.12) .50 (.12] .50 [.12] .50 [.12] ' 55 -85 =10'AU Temperature Rise Range °F 30 -60 25 -55 30 -60 40 =70 • 25 -55 [30.6 -47.2] 40 -70 40 -70 50 -80 1 °C] [16.7 -33.3] [13.9 -30.6] [16.7 -33.3] [22.2 =38.9] [13.9 -30.6] 45 -75 = 10'AM [22.2 -38.9] [22.2 -38.9] [27.8 -44.4] : .1 4. a. [25 -41.7] Max. Outlet Air Temp. °F 155 155 165 • ' 165 ; 155 190 190 180 190 ( °C) [68.3] [68.3] [73.9] , .- [73.91 [68.3] [87.8] [87.8] (82.2) [87.8] Standard Filter [mmj (1) 14 x 20 [356 x 508] (1) 14 x 20 [356 x 508] (2) 12 x 20 [305 x 508] (2) 12 z 20 [301X 508] (2) 12 x 20 [305 x 508] (2) 12 x 20 [305 x 508] (2) 14 x 20 [356 x 508] (2) 14 x 20 [356 x 508 ( x (2) 20 Approx. Shipping Weight (Lbs.) 85 85 105 05 105 115 120 140 150 [kg] [38.6] [38.6] [47.6] .147.6] [47.6] [52.2] [54.4] [63.5) [68.0] AFUE- Standing Pilot Models O 78% 79.5% 78.4% 78.6% 79.2% 78% 78% 78.1% 78.5% AFUE - H.S.I. Models OO 81.1% 82.2% 80.7% _..:. 80.5Vi 81.1% 80.2% 80% 80% 80% California Seasonal Efficiency- H.S.I./No, Models 73.8/73.9 75.9/76.2 73.8/73.9 74.4/74.9 75.1/75.5 75.2/75.2 74.7/74.7 75.2/75.3 76.0/75.9 BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS U.S. AND CANADA MODELS (DOWNFLOW NOTES: All models are 115V, 60HZ, 10. Gas connection size for all models is 1 /2' N.P.T. pp In accordance with D.O.E. test procedures. p See Conversion Kit Index Form No. 92- 21519 -52 for U.S. models and Form No. 92- 21519 -53 for Canadian models for high altitude derate. MODEL IDENTIFICATION DOWNFLOW MODELS R G L H - 07E A U E R Rheem Gas Downflow Design Heating Input Designation Variations Blower Heating & Cooling Fuel Type Furnace Series [ ] Designates Metric Conversions Standing NOx Electric NOx Input Pilot Model Ignition Model BTU /HR 045 04M 04E 04N 45,000 [13 kW] 050 05M 05E 05N 50,000 [15 kW] 067 06M 06E 06N 67,500 [20 kW] 075 07M 07E 07N 75,000 [22 kW] 100 10M 10E ION 100,000 [29 kW] 125 12M 12E 12N 125,000 [37 kW] 150 15M 15E 15N 150,000 [44 kW] A = Std. Designation Designation R = Natural Gas, Cabinet U = 11 x 6 S = 500 -1200 CFM U.S. Standard B = Wide [279 x 152 mm] [236 -566 Us] Furnace Cabinet M =11 x 7 E 1100 - 1330 CFM A = Natural Gas, [279 x 178 mm] [519 - 628 Us] Canadian R = 11 x 10 G = 1450 -1750 CFM Standard [279 x 254 mm] [684 -826 Us] Furnace J = 1800 -2075 CFM [850 -979 Us] : ,. r ' ---• 04, 05 14 • 3/ [19 mm) 34" (864 [326] 26 /e" (676 mm) 1 /2' DIA. [13 mm] Ms" DIA. (676 mm) —" LOW VOLTAGE mmJ 1594 (333] [22 mm) . ,,.. 4 CD mm] mm) 6 - 24 ELECTRICAL CONNECTION (HIGH VOLTAGE) .' 2613/,.' [518 mm] 23 1594 0 - -II - 11 - 0 1 I , I I 1 1 _ _ ! _ _ ! _ _ [681 mm] 16 [415] [518 /e . mm] O (621 mmJ GAS CONNECTION 6 [157 mm] - f 3 CD 0 r [25] 3 p/ }e" (157 mm) I - 1 DIA. [35 mm] : ,. r ' ---• 04, 05 14 [356] 12 [326] 10 [264] O 13 (333] p. ...e.41 0 . ,,.. 4 CD 0 �.,: :7rrr � 1 [25] 3 [76] 6 F II [152] CD �F 85 1' Is��' [38.6] 06, 07 17 [445) 16 [415] 12 [308] O 16 /8 [422] 0 3 CD 0 1 [25] 3 [76] 6 [152] ® 105 [47.6] 10 (A) 17 [445] 16 [415] 12 (308] O 16 [422] 0 3 CD 0 1 [25] 3 [76] 6 [152] 20 115 [52.2] 10 (B) 21 [533] 19 [504] 13 [352] O 20 [511] 0 0 0 1 [25] 3 (76] 6 [152] ® 120 [54.4] 12 24 [622] 23 [593] 15 [397] O 23 [600] 0 0 0 1 [25] 3 [76] 6 (152] CD 140 [63.5] 15 24 [622] 23 [593] 15 [397] CD 23 [600] 0 0 . 0 1 [25] 3 [76] 6 [152] CD 150 [68] NOTES: rn May reauire a 3'176 mml to 4'1102 mml or 3' (76 mml to 5' 1127 mml adaater. DOWNFLOW DIMENSION° LEFT SIDE r 1 1104lnnMfa• elPirIn enmMrcInnc A R.A. 6/e' fl B —+{ 6 /e" (16 mml (16 mm[ { TOP FRONT BOTTOM /18" S.A. E 19 [502 Mm] i 3/ (19 mm] • 28 [713 mm] TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] 20 /e' D ['-r(511mm1 RIGHT SIDE 6 / [16 mm] m May be 0' [0 mm] with type B vent. CD May be 1' [25 mm] with type B vent. Furnaces must be vented in accordance with ANSI Z21.47-1993 • CAN /CGA- 2.3 -M93 venting table guidelines Included with each furnace, and in accordance with local codes. 0 Y _". J I I 1 I. � a T r . ... .. I _ .. _ .... ... .. .... . Y.: .. ._j .. (MWLI ..-1 %j�..,,— . i'LJ•.,a. :,V: li 045AUS' LOW 6 1.e(��... r !/ 685 [323] I �i:..... 650 [3071 F:tiwt.w. 615 .`.. uri (2901 usil 580 n L: ��:. ( .LL.s,i [2 .. i41 545 [2571 A4 l� �•i. 4,r6 iJ. [/ 510 [241] 470 [222] 04MAUSR 11 x 6 1/2 MED -LO 980 [463] 955 [451 ] 930 [439] 900 [425] 870 1411 ] 840 [396] 805 [3801 04EAUS' [279 x 152] [373] MED -HI 1220 [5761 1195 [564] 1170 [552] 1135 [536) 1100 [519] 1065 [5031 1020 [481) 04NAUSR HIGH 1465 [691] 1440 [680] 1405 [663] 1365 [644] 1325 [625] 1280 [604] 1230 [5801 050AUE' LOW 735 [347] 715 [337] 690 [326] 660 [311] 635 [3001 605 [286) 575 [271] 05MAUER 11 x 6 1/2 MED -LO 1025 [484] 1015 [479] 995 [470] 975 [460] 955 [451] 930 1439] 905 [427] 05EAUE' [279 x 152] [373] MED -HI 1185 [559] 1165 [550] 1150 [543] 1130 [533] 1100 [519] 1075 [507] 1040 [4911 05NAUER HIGH 1345 [635) 1330 [628] 1310 [618] 1295 [611] 1265 [597] 1235 [583] 1205 [569] 067AUE' 06MAUER 06EAUE' LOW 835 [394] 820 [387) 800 [3781 775 [366) 750 [354) 720 1340] 685 [323) 06NAUER 11 x6 1/2 MED -LO 990[467] 975 [460] 955 [451] 935 [441] 905 [427] 875 [413] 835 [394] 075AUE' [279 x 152] [373] MED -HI 1140 [538] 1125 [531] 1105 [522] 1080 [510] 1050 [496] 1020 [481] 980 [463] 07MAUER HIGH 1300 [614] 1290 [609] 1265 [597] 1245 [588] 1215 (573] 1180 [557] 1140 [5381 07EAUE' 07EAUER 075AMG' LOW 1210 [571] 1205 [569] 1195 [564] 1180 [557] 1165 (550] 1155 [545] 1130 [5331 07MAMGR 11 x 7 3/4 MED -LO 1580 [746] 1560 [736] 1550 [732] 1530 [722] 1495 [706] 1465 1691 ] 1430 [675] 07EAMG' 1279 x 1781 [559] MED -HI 1915 [904] 1880 [887] 1825 [861] 1790 [845] 1740 1821 1 1675 [791] 1600 [755] 07NAMGR HIGH — 2050 [967] 1995 [942] 1940 [916] 1885 [8901 1835 [866] 1770 [835] , •-,- I 111 --i- —J .. t''1' 'AP Mr. - '` `''TFj "713 .:t. - t.1 .. r - .'t ; , ' I; ... q.P -4" 3891 10EAME* 11 x 7 1/2 MED -LO 1070 [505] 1055 [498] 1040 [491] 1010 [477] 980 [463] 945 (446) 905 [427] 10NAMER [279 x 178] [373] MED -HI 1240 [585] 1210 [571] 1190 [562] 1165 [550] 1135 [536] 1095 [517] 1055 [498] r .. . T . ' r HIGH 1420 1395 Tip .r:1:Y71•I.1F,'-' [658] [1 : 1 1370 I . 7 [647] 1340 [632) 1305 [616] i -- IF NW) ;T 1265 [ 1220 - [ [ 5 y 7 � 6 ) �� y i#1 it1 %;ir` I'':m4 ; 111 r, W1�7� "'. . it ie. 1 .1;.M1 100AUE* 11 x 6 1/2 MED -LO 1020 [481] 1000 [472] 980 [463] 965 [455] 930 [4391 895 [422] 860 [406] 10MAUER [279 x 1521 [373] MED -HI 1170(552] 1160 [547] 1140 [538] 1110 [524] 1080 [510) 1040 [491) 995 [470) HIGH 1330 [6281 1300 [614] 1270 [599] 1235 [583] 1200 [566] 1160 [547] 1115 [526] 100BRJ* LOW 1330[628] 1295 [611] 1285 [606] 1245 [588) 1225 [578] 1205 [569] 1160 [547] 10MBRJR 11 x 10 3/4 MED -LO 1690 (798] 1670 [788] 1655 [781] 1615 [762] 1585 [748] 1565 [739) 1525 [720) 10EBRJ' (279 x 254] [559] MED -HI — 2085 [984] 2055 [970] 2005 [946] 1970 [930] 1945 [918] 1880 [887] 10NBRJR HIGH — 2410 [1137] 2355 [1111] 2305 [1088] 2240 [1057) 2165 [1022] 2100 [991j 125ARJ' LOW 1330 [6281 1295 [611] 1280 [604] 1240 [585] 1215 [573] 1210 (571] 1175 [555] 12MARJR 11 x 10 3/4 MED -LO — 1690 [798] 1660 [783] 1635 [772] 1580 [7461 1535 [724] 1480 [698] 12EARJ' [279 x 254] [559] MED -HI — 2090 [986] 2035 [960] 1985 [9371 1930 [911 ] 1850 [873] 1785 [842) 12NARJR HIGH — 2395 [1130] 2335 [1102] 2260 [1067] 2185 [1031] 2080 [982] 1965 [927] 150ARJ' LOW 1300 [614] 1280 [604] 1230 [580] 1205 [5691 1170 [5521 1115 [526] 1030 [486] 15MARJR 11 x 10 3/4 MED -LO 1675 (791 ] 1650 [779] 1620 [765] 1570 [741] 1545 [729] 1485 1701 ] 1425 [6731 15EARJ* [279 x 254] [559] MED -HI 2105 [993] 2075 [979] 2035 [960] 1990 [939] 1955 [923] 1900 [897] 1815 [857] 15NARJR HIGH — 2340 [1104] 2290 (1081) 2215 [1045) 2145 [10121 2080 1982] 1995 [942] 0 BLOWER PERFORP MINCE DATA- D0WNFL01" MODELS NOTES: 'Designates "R" for U.S. models, and "A" for Canadian models. "Not to be used as a heating speed. Data compiled with factory filters installed. [ ] Designates Metric Conversions ir 0 C o W J N WO gQ co 3 t- Z � I 0 Z H W W U � 0 — 0 t— W W F- W Z co U O FURNACE tIN [in ;470,.. 14 [356] .P,LE U 4 '.<< 1 `W a c ..Nl`Iri ) ;,h' 16 ,;.: :;.; t rLI t ' . : k �,L, RXAA -C178 . , : ' 01 ., � : fiUM « `( r.,..i :t _l it ', RXAL -B16BU 14 [356] 20 [514] RXAA -C179 RXAL -B20BU 17 [445] 16 [413] RXAA -C186 RXAL -B16BU 17 [445] 20 [514] RXAA -C180 RXAL -B2OBU 17 [445] 21 [549] RXAA -C189 RXAL-B21BU 17 [445] 25 [641] RXAA -C181 RXAL -B25BU 21 [533] 22 [565] RXAA -C182 RXAL -B22BU 21 [533] 25 RXAA -C183 RXAL -B25BU 24 [622] 25 [641 ] RXAA -C184 RXAL -B25BU 24 [622] 21 [549] RXAA -C190 RXAL -B21BU COMBUSTIBLE OAR SASE" , USE' i '� �.,g RXGC -B14 RGLH -04, 05 14 [368] 13 (337] 11 [286] RXGC -B17 RGLH -06, 07, RGLH- 10( -)A 18 [457] 16 [425] 14 [451 ] RXGC -821 RGLH- 10( -)B 21 [546] 20 [514] 18 [464] RXGC -B24 RGLH -12, RGLH -15 25 [635] 23 [603] 21 [552] ACCESSORIES - DOWP`'! OW DOWNFLOW WARNING: Unit design Is certified for installation on non•com• buatible floor. A special factory supplied combustible floor sub -base is required when Installing on a combustible floor. Failure to install the subbase may result in fire, property damage and personal injury. COMBUSTIBLE FLOOR BASE DIMENSIONS 19t/2" (495 mm] -el 7 - I 1 1 1 1 28 7 (184 mm) --41 [51 mml 2" (721 mm) L_ 211/2" 1 Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. FIBERGLASS 3 LB. [1.4 kg] DENSITY 4 " [102 mm 3" [76 mm] I A I FLOOR NOTE: FLOOR OPENING 21 "546 mm) x B MAX. P LENUM SIZE 19 (495 mm] x C RHEEM AIR CONDITIONING DIVISION .., ...,:.u..u.v.v,.vw�:.�. . • PLENUM DATA — "A" COILS Plenum adapters are required in some instances for use on downflow applications when plenum and furnace size do not match. NOTE: See Form Number C11 -206 fo MultiFlex coil data. RXGW -AAA01 Humidifier and Electronic Air Cleaner Accessory Board for Robertshaw Control RBC1 and Honeywell ST9101 A 1014 Blower Controls. NOTE: Available for standing pilot models only. 1" (25 mml T' FIBERGLASS 3 LB. (1.4 kg] DENSITY PLENUM OR DUCTWORK P.O. Box 17010, Fort Smith, Arkansas 72917 -7010 RXPF -F01 and F02 FOSSIL FUEL KIT —is for use with Rheem Heat Pumps and Criterion II warm air furnaces. RXPF -F02 meets TVA requirements. RXGF -CC* FILTER RACK — Downflow top return mount. NOTE: Filter racks are shipped without filters. *Filters available through the Universal Parts® Department. GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Gas Heat Exchanger Limited Warranty Twenty (20) Years Draft Inducer Limited Warranty Five (5) Years Integrated Control Board Limited Warranty Five (5) Years (Standing Pilot and Hot Surface Control Boards) Any Other Part One (1) Year For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. i "In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice." PRINTED IN U.S.A. 8-96 BP FORM NO. G11.449 REV. 2 Supersedes Form No. G11.449 Rev. 1 RHEEMGLAS Fury Plus High Performance, Energy Miser® FILE COPY 1 Gas Water Heater Available in 40 and 50 gallon tall 30 and 40 gallon lowboy models • 5 -Year Limited Tank Warranty* • 1 -Year Limited Parts Warranty* • High performance and recovery CITY OF T: A ji1 1 :. �) t U 2 'I RECEIVED • Patented R -Foam® insulation process for C1T { OF 1U1<VJILP superior heat retention ,1UN 1 0 20 • Gasmaster'" burner with precision port 1T CENTER alignment for even heat transfer PERM • Heat saving flue baffle design • Compliant with many gas utility incentive programs ** • Meets or exceeds National Appliance Energy Conservation Act (NAECA) requirements • See Residential Warranty Information Brochure for complete warranty information. "40,000 BTU models only. SPECIFICATIONS n ' . r, ' Gas Input First Hour T Tank In Thousands. Recovery in Delivery APpx. . G.P.H. Y Model Cap I BTU /Hr. Rating Energy•Shpg. P Numbert go RI" G.P.H. actor'Wght.i E Gals.. LP Lbs. Nat. Sumer Nat. LP Nat. LP A B C D E F G H 41VR40 40 40 40 40.4 40.4 68 ' 68 0.62 127 , 61% 581/2 21 8 3 131/2 2 1/2 Roughing In Dimensions (Shown In Inches) A 41VR4ON• 40 37.5 — 40.4 — 68 — 0.62 127 ;61 581/2 .21 8 3 . 131/2 2 '/ L 141VR50 1 50 140 40 140.4 40.4 i 74 i 74 1 0.62 i 151 L 1603/4 157% 123 8 3 � 13'/ ! 2 LOW BOY 41VR50N' 50 40 — 40.4 — 74 — 0.62 151 60% 57% 23 8 3 13% 2 '/ 41 V30S 30 34 34 34.4 34.4 54 54 0.58 109 501/2 461/2 17'/% 8 3 13% 2 '/ 41V40S 40 37 37 37.4 37.4 65 65 0.56 138 521/4 481/4 191/4 8 _ 3 131/4 2 1/4 41V50S• 50 40 40 40.4 40.4 73 73 0.53 140 54 48 %2 22% 8 3 13% 2 1/2 For SCAOMD rule 1121 compliance (California only). Side relief valve connection on model 41V5OS only. t Specify LP gas when ordering. Add "P" suffix to the model number. Example. 41VR4OP Wr 11"A. MELar VALVE OVUM W' NAT. MIME VALVE 1111MMIQ _..._ ... - ra.,ronwri ?"�aMkY?'1'"�wir#__ MtR'3!V�i51: fo.w', THESE UNITS ARE DESIGNED TO MEET OR EXCEED A.N.S.I. (AMERICAN NATIONAL STANDARDS INSTITUTE) AND HAVE BEEN TESTED ACCORDING TO D.O.E. TEST PROCEDURES AND MEET OR EXCEED THE ENERGY EFFICIENCY REQUIREMENTS OF NAECA, ASHRAE STANDARD 90, BOCA CODE AND ALL STATE ENERGY EFFICIENCY PERFORMANCE CRITERIA FOR ENERGY CONSUMING APPLIANCES. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. The number one choice of plumbing professionals. RHEEM MANUFACTURING COMPANY WATER HEATER DIVISION 101 Bell Road, P.O. Box 244020, Montgomery, Alabama 36124 -4020 PRINTED IN U.S.A 3.97 WP nrwm ^"w,rt4 elrmmasr, 1 RHEEMGLAS® Fury Plus Energy Miser® CONSTRUCTION FEATURES 1. R -Foam Insulation —Rigid polyurethane foam for improved economy and fuel savings. The use of our patented insulator foam stops allows R -Foam to be injected directly between the tank and outer jacket. This uniform R -Foam application minimizes the possibility of costly heat loss caused by uninsulated areas (voids) common to some other foam processes. 2. Rheemglas Tank— Rheem® water heater tanks are made of special materials with exacting care. The tank surface is coated with an exclusive porcelain formula called Rheemglas and fused to the solid steel at 1600'. The result is a smooth, tough, glass -like lining that effectively resists the corrosive attacks of hot water chemicals, thereby assuring long water heater life. Tank is designed and tested to withstand 300 PSI hydrostatic test pressure for working pressure of 150 PSI, A.N.S.I. Standard. 3. Gasmaster Burner — Durable aluminized steel construction. Designed for efficient, quiet operation; precision port alignment; even heat transfer. Factory adjusted for natural gas. LP models feature a durable stainless steel burner designed specifically for LP gas. 4. Flue Baffle —New design— special baffle restrictor discs provide greater retention of flue gases. Keeps heat in flue longer for maximum heat dispersion to tank water. Retards air movement through flue during standby periods, minimizing heat loss. 5. Robertshaw• Control— Combination thermostat with factory preset balanced pressure regulation and built in E.C.O. (energy cut -off). LP models feature the R65RR control, the most advanced LP gas control available. 6. Anode Rod — Equalizes aggressive water action; different types factory installed and designed to match local water chemical characteristics throughout the U.S. 7. Dip Tube —A durable plastic formula, tougher, more heat resistant than ever before. 8. Relief Valve Opening —( %' N.P.T.) top connect Is exposed for faster, economical installation. 9. Drain Valve— Non - metallic, corrosion proof, designed for quick draining. 10. The Draft Diverter —Low profile design Is proven, efficient. THE GASMASTER BURNER Durable aluminized steel construction. Designed for efficient, quiet operation; precision port alignment, even heat transfer. Features energy saving low input pilot — only 350 to 400 BTUH. Well protected to maintain alignment, yet easy to light. — y in keeping with its policy of continuous progress and product Improvement, Rheem reserves the right to make changes without notice." FORM NO. 101-9 REV. 9 Z 1 Ix QQ � J O 00 (f) W W J CO W WO QQ N � _ W Z � 1— O Z W W U O 0- O H W W H- U- O Lil Z 0- O~ Z ACTIVITY NUMBER: MO2 -118 PROJECT NAME: LOWER !UNCTION - LOT 6 SITE ADDRESS: 5436 S. 150 STREET X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DEPARTMENTS: G��b� Mai y60. � 6-1111' Builldi DDivision ® � Fire Prevention © Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [s Comments: Permit: Center: Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route [Yr Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2-28.02 t- CRMIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete PERMIT COORD COPY DATE: 6 -10 -02 Revision # After Permit Is Issued DUE DATE: 6-11 -02 DUE DATE: 7-09 -02 Not Applicable ❑ Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: M REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST: # 'EXP. DATE CCO1 •TRYONCL013DH 02/11/2003 EFFECTIVE:- DATE 03/08/1999 TRYON CONCEPTS LLC PO BOX 146 • RENTON WA 98057 Issued by DEPARTMENT OF LABOR AND INDUSTRIES 1