Loading...
HomeMy WebLinkAboutPermit M02-123 - REI SOUTHCENTERREI SOUTHCENTER 230 ANDOVER PARK WEST U UO0 cow CO IL WO u.< se a z. W 0- o f- W W H. Cum ii = z Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Permit Center Authorized Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0223100070 230 ANDOVER PK W TUKW REI SOUTHCENTER 230 ANDOVER PK W, TUKWILA, WA THE SEATTLE FUR EXCHANGE, INC. ATTN: JAMES E. SWEENY, PO BOX 88159 STEVE SWANSON MITHUN, 1201 ALASKAN WAY #200 Contractor: Name: G B SYSTEMS INC Address: 7202 NE 175TH. ST, KENMORE, WA Contractor License No: CBSYSI *088BS Value of Construction: $30,000.00 Type of Fire Protection: SPRINKLERS MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: 206 - 246 -7611 Phone: 206 - 623 -3344 Phone: 425 -482 -0584 Expiration Date: 01/10/2003 DESCRIPTION OF WORK: ADD TWO NEW AC UNITS AND MODIFY EXISTING DUCTWORK FOR TENANT IMPROVEMENT. MO2 -123 Fees Collected: Uniform Mechnical Code Edition: Date: 8`/ D a MO2 -123 08/01/2002 01/28/2003 $142.19 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Date: — 1'0 o� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 08 -01 -2002 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223100070 Address: 230 ANDOVER PK W TUKW Suite No: Tenant: REI SOUTHCENTER PERMIT CONDITIONS 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 10: Manufacturers installation instructions required on site for the building inspectors review. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 15: Local U.L. central station supervision is required. (City Ordinance #1900) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 18: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and Tukwila Fire Department job Number available doc: Conditions MO2 -123 Printed: 08 -01 -2002 Permit Number: MO2 -123 Status: ISSUED Applied Date: 06/13/2002 Issue Date: 08/01/2002 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 to confirm shut down approval. (City Ordinance #1900) 19: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 20: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 21: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575- 4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions MO2 -123 Date: E Printed: 08 -01 -2002 Project Name/Tenant: p r 1 , e % Cevite , / Value pan I E uipment: ' 2W P c N X, - PAYI4 'JIv' W 41 Ili KWl i Staa 6g Ta t� a Z2- , t p) - U0 /CO - 04 '4 n r2 ( r 020040 NFAT7Y1 Phone: (2r73) jfiG., $1. L ttie 9 t A exam /rr to , 9 s.s5 „Ity State/Zip: Fax #: ) Contractor: pc Phone: ( ) Street Address: City State/Zip: Fax #: ( ) Contact eAurci I Cv' f VY1 j'n- t'l�t� Phone (206) &23. 344 Street Address: V �,,� r 71 ITV* s t . I` �1-r le °WO '..111 Qty S�� iip: Fax #: ( ) 62 11,0C 7 CITY OF T"KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 R SIMI E USE ONI Y Project Number. ---/A011-4a3--- Permit Number. Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICALP,ERMIT. REVIEW, AND APPROVAL?REQUESTED6=(10 BE:FIILED;OUT BYAPPLI,CANT), Description of work to be done (please be specific): ADD 'tW V N i PC, UNITS P q D vt STf N h OtrilAtYr.. re.5ta rCN "NT% W QgOV Fi vY1 F7( Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. ;; ::OR�AUTHORIZE CENT: BUILDING ?' NE Signature. Print name: Address , ?S 5•22 Date: c • ( • oz. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: b i3 - oa- Date application expires: /0-13 Application taken by: (initials) 11/2/99 reech pem►ii.doc ✓ /►' Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) r Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. . Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal 11/2/99 miscpmr.doc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace v �► Narrative with specification of equipment and chimney type. li u g exJing chimney, provide a letter by a certified chimney sweep stitin ...S Cab 4 : -3 • e • - `..+ . 1 IS' gam . ..• y - s titer ,, t4 an' 'v -� '�cluded in the Unifo N4i i ill ti p, lVase, kcluc a �,�w� eels r ven s ipstalledorreplaced. Y'P� • City of iukwi1a 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223100070 Address: 230 ANDOVER PK W TUKW Suite No: Applicant: REI SOUTHCENTER Payee: GB SYSTEMS, INC TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt Current Pmts Amount RECEIPT Type Method Description Payment Check 15347 142.19 Description Account Code MECHANICAL - NONRES 000/322.100 113.75 PLAN CHECK - NONRES 000/345.830 28.44 Permit Number: MO2 -123 Status: APPROVED Applied Date: 06/13/2002 Issue Date: Receipt No.: R020001084 Payment Amount: 142.19 Initials: SKS Payment Date: 08/01/2002 02:00 PM User ID: 1165 Balance: $0.00 Total: 142.19 13 /o' ' TO a 11:: 1) ,,... v 4....w,... Printed: 08 -01 -2002 Project: Type of Inspection:. —. t1not Add ess: . )- td A PO Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: 4 2 T) ' INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: � r rPck` l arts --Pro wet Rep ci rp ro veL9 �e �rw, ►-� Cam, .l�-I. Calms Fi J Inspectors Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. (Receipt No.: 'Date: :M1- P r q ; Type of anion: _ u t 0 (" A ressr.:. qty: ` • R44) : Date Called: lam Dg Spec I � ( Date Wante a : m. Requester, A) Pho N. App codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY TUKWILA BUILDING DIVISION 6300,Southcente' Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS:. R h c — /0 — ikm\rWmi C S1 sIv'e s; R. /*PS 'Ace F . h ' IL F T 'P" I / :F} l . AAA Q.q s ieVV) .El1c°17,c6: 1 Ro `1- 21&)1 (n btu e b P i ispe@ %tor: Date: / f a d 7 REINSPECTIO FEE REQUIRED. Prio to Inspection, fee must be . aid : at t300.Southcenter Blvd., Suite 100. all to schedule reinspection. Receipt No:; Date: Pr ct: /i Type • • n pe 4, A t 1! " ; . `'' graire4/0/k Avn vv. Date at ed: i / Special Instructions: Date Wanted: / f 0i7 j 62, a.m. p.m. Requester: 2 1371 Phone 720 0 5,7/' ^ 3,77 INSPECTION RECORD { { Retain a copy with permit � oa3 INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - � �J 6300 Southcenter Blvd., #100, Tukwila, WA8� � )431 -3670 C V COMMENTS: Cig, 7/-22°--) 1-, - /s4 • Approved per applicable codes. Corrections required prior to approval. $47.00 REINSPE ON 'E REQUIRED. Prior to inspection, fee must be paid at 1300 Southcenter Blvd., Suite 100. Call to schedule.reinspection. `Receipt No.: 'Date: Prit L Type f lnsp tion; A : col 14els: 4 .70 1 6 . 0 , , p g 14 Date Called: ONt 2 Special Instructions: Ge-- ,O r 1 :Ae, L . viae - eArteA Date Wanted: /0/..-7/ a.m. Requester 9 Phone No 3 r Approved per applicable codes. INSPECTION RECORD Retain a topy with permit INSPECTIONINO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 CaMMENTS: 1 • it d;e-c-4-1 5 e....-tz."1„...-.e_e/ P /p t p1,97-7 nee.46/ I f' Corrections required prior to approval. $47.00 REINSPECTION FEE EQUIRED. Prior to inspection, fee must be paid at t 300 Southcenter Blvd., Suite,100. Call to schedule reinspection. Receipt No.: 'Date: f • COMMENTS: 4Cir({ Aur+ \ -e4 d clIrea Auci Lve.1 ✓ gwer , ( 'W\f Z2q 11 ( `--G +r r � Au Ci SAthrca i P G r r-, (AAA is PvI1C 6(0104 a Req / ester: IG / • r - o . � ne 1. 3 0 ''�lv 7 Proj Typ Inspection:: A/ Address: A 02/2i t Mov Date C ed: --oa— Special Instructions: Al , ,) Date Vy�nteed: a Req / ester: IG / r - o . � ne 1. 3 0 ''�lv 7 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. 'Inspector: INSPECTION RECORD Retain a copy with permit Rcm4„ei, (206) 431 -3670 Date. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: sou , i ∎!' f ..i;. � a. . n INSPECTION RECORD Retain a copy with permit INSPE • N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. v. ,�3o 9N�v�lC/�7r 4.)D cial Inst uction Date 4(anted: a. RequeSter� Ph Y ,ll7) 5 7/ - 2 3 7 TyKof Inspection: n 1(6 - /4J ate Cail Corrections required prior to approval. COMMENTS: Date t 3 - 2 S4 .1 s REINSPECT ON FEE REQUIRED. Prior to inspection, fee must be paidatt300Southcenter Blvd., Suite 100. Call to schedule reinspection. 5.44. �r�water W%LA,. iv .6. (:) mot -, )1) Steven M. Mullet Ma City of Tukla , 7 , + ,� y or J +�, 1•j' t ;-* / : Fire Department Thomas P. Keefe, Fire Chief 1908 7 77:7 ,.,ltu�Y.7.7, 77, .43 :; .r77- . +k+.:� 1,,j7 G" M I.T' .. t " .� • Project Name 11 ET TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Address , 'T3U )A d0.) ---Retain- current inspection. schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: \ !)\ - ..46:1 - P p1 - 5) Authorized Signatufe FINALAPP.FRM Rev. 2/19/98 Permit No. ill o--" 93 Date Suite # 0(f )1 0 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 TOTAL SENSIBLE SHR COOLING STUN PER ZONE BTUH BTUH CFMo1 55 SO. FT. RETAIL 493197.1 383120.0 0.78 17655.3 33.0 SHOP 13305.1 11241.6 0.84 518.0 24.6 STORAGE 24243.2 23670.0 0.98 1090.8 7.5 TLT -RMS 3332.4 2759.2 0.83 127.2 7.2 LOCKERS 8464.5 6744.9 0.80 310.8 14.3 OFFICE 20173.5 17802.7 0.88 820.4 19.5 TOTAL 562715.6 445338.3 HUf'c (-OA 1D C c - c LOADS SHOWN BELOW HAVE BEEN EVALUATED AT 48 DEGREES NORTH LATITUDE REI-SOUTH-CTR COOLING LOAD SUMMARY HEATING LOAD SUMMARY 20522.5 HEATING HEATING WATTS PER BTUH KW SO. FT. 435435.6 127.6 8.5 7438.0 2.2 4.0 17255.0 5.1 1.6 2235.0 0.7 1.4 4740.0 1.4 2.3 9657.6 2.8 2.7 476761.2 139.7 HECEIVED OF TUKWILA 1 3 2001. PERMIT CENTER CITY OF TUKWILA APPROVED JUL 2 9 20n Ki 1.40 ILO '1_011,10 -. 'i 1 CALCULATIONS FOR ZONE RETAIL ASHRAE CLTD /CLR COOLING LOAD CALCULATIONS PEAK MONTH - JUL OUTSIDE TEMP 84 LATITUDE 48 PEAK HOUR - 4PM INSIDE TEMP 75 GLASS SOLAR GAIN - FACTORS- DIR TYPE LF HT SOLAR GLASS W 2 30.0 X 16.0 X 85.9 X .85 = GLASS TRANSMISSION GAIN TYPE AREA U TD 2 480.0 X .65 X 9 = 2808.0 WALL SOLAR AND TRANS GAIN DIR TYPE LF HT U TD W 1 54.0 X 24 X 0.080 X 68 = 7050.2 W 2 30.0 X 8 X 0.080 X 68 = 1305.6 ROOF SOLAR AND TRANS GAIN AREA U TD 14468 X .05 X 58 X 100 % = 41957.2 SKYLIGHT SOLAR AND TRANS GAIN AREA SOLAR STOR SHADE TRANS 480 X 244 X .62 X .66 + 2462.4 = 50387.9 INTERNAL GAINS AREA 14948 SO FT PEOPLE 299.0 PEOPLE X 245 LIGHTS 22422 WATTS X 3.413 X 100 % = INFIL. 2989.6 CFM X 1.08 X 9 = MISC BTUH TOTAL ROOM SENSIBLE BTUH PLENUM LIGHT HEAT AT 0 X PLENUM ROOF HEAT AT 0 % FAN MOTOR HEAT AT 8 % ROOM SENS. VENT. 2989.6 CFM X 1.08 X 9 TOTAL SENSIBLE BTUH 0.A.LATENT 5979.2 CFM X .68 X 12 = PEOPLE LATENT 299.0 PEOPLE X 205 = GRAND TOTAL BTUH 363.7 SO FT /TON 0.78SHR BTUH SHADE % 35032.4 0.27 LOAD CALCULATION FOR RE1- SOUTH-CTR PREPARED BY DEHAAS ENGINEERING KENT WASHINGTON 05 -14 -2002 W.F. W /GLASS 130.6 1304.9 BTUH I.F. W /ROOF 73245.2 17.4 76526.3 29193.4 10203.5 327709.8 0.0 0.0 26216.8 29193.4 383120.0 48790.3 61286.8 493197.1 41.1TONS GLASS TRANSMISSION LOSS TYPE AREA U TD 2 480.0 X .65 X 50 = 15600.0 WALL TRANSMISSION LOSS DIR TYPE AREA U TD W 1 1296.0 X 0.080 X 50 = 5184.0 W 2 240.0 X 0.080 X 50 = 960.0 ROOF TRANSMISSION LOSS AREA U TD 14468 X .05 X 50 = 36170.0 SKYLIGHT TRANSMISSION LOSS AREA U TD 480 X .57 X 50 = 13680.0 SLAB LOSS 84 LF X 25 BTUH = 2100.0 HEATING LOAD CALCULATIONS OUTSIDE TEMP 20 INSIDE TEMP 70 INFIL. LOSS 2989.6 CFM X 1.08 X 50 = 162185.8 VENT. LOSS 2989.6 CFM X 1.08 X 50 = SPACE HEAT LOSS = PICK -UP LOAD TOTAL HEAT LOSS 8.5 WATTS /SO FT 162185.8 398065.6 = 37370.0 • 435435.6 127.6 KW CALCULATIONS FOR ZONE SHOP REI-SOUTH-CTR ASHRAE CLTD /CLR COOLING LOAD CALCULATIONS PEAK MONTH - JUL OUTSIDE TEMP 84 LATITUDE 48 PEAK HOUR - 3PM INSIDE TEMP 75 ROOF SOLAR AND TRANS GAIN AREA U TD 508 X .05 X 51 X 100 X = 1295.4 SKYLIGHT SOLAR AND TRANS GAIN AREA SOLAR STOR SHADE TRANS 32 X 244 X .66 X .66 + 164.2 = 3565.3 INTERNAL GAINS AREA 540 SC FT PEOPLE 7.2 PEOPLE X 245 = LIGHTS 810 WATTS X 3.413 X 100 X = MISC BTUH TOTAL ROOM SENSIBLE BTUH PLENUM LIGHT HEAT AT 0 % PLENUM ROOF HEAT AT 0 X FAN MOTOR HEAT AT 8 % ROOM SENS. VENT. 72.0 CFM X 1.08 X 9 TOTAL SENSIBLE BTUH 0.A.LATENT 72.0 CFM X .68 X 12 = PEOPLE LATENT 7.2 PEOPLE X 205 = GRAND TOTAL BTUH 487.0 SG FT /TON 0.84SHR BTUH 1.F. W /ROOF 1764.0 12.8 2764.5 368.6 9757.9 0.0 0.0 780.6 703.1 11241.6 587.5 1476.0 13305.1 1.1TONS HEATING LOAD CALCULATIONS OUTSIDE TEMP 20 INSIDE TEMP 70 ROOF TRANSMISSION LOSS AREA U TD 508 X .05 X 50 SKYLIGHT TRANSMISSION LOSS AREA U TD 32 X .57 X 50 SLAB LOSS 0 LF X 25 BTUH = 1270.0 = 912.0 0.0 VENT. LOSS 72.0 CFM X 1.08 X 50 = 3906.0 SPACE HEAT LOSS = 6088.0 PICK-UP LOAD = 1350.0 TOTAL HEAT LOSS = 7438.0 4.0 WATTS /SO FT 2.2 KW 1 CALCULATIONS FOR ZONE STORAGE REI- SOUTH-CTR ASHRAE CLTD /CLR COOLING LOAD CALCULATIONS PEAK MONTH - JUN OUTSIDE TEMP 77 LATITUDE 48 PEAK HOUR - 5PM INSIDE TEMP 75 ROOF SOLAR AND TRANS GAIN AREA U TD 3234 X .05 X 64 X 100 % = 10348.8 INTERNAL GAINS AREA 3234 SO FT BTUH I.F. W /ROOF PEOPLE 2.0 PEOPLE X 245 = 490.0 6.8 LIGHTS 3234 WATTS X 3.413 X 100 % = 11037.6 MISC BTUH 0.0 TOTAL ROOM SENSIBLE BTUH 21876.4 PLENUM LIGHT HEAT AT 0 % 0.0 PLENUM ROOF HEAT AT 0 % 0.0 FAN MOTOR HEAT AT 8 % ROOM SENS. 1750.1 VENT. 20.0 CFM X 1.08 X 2 = 43.4 TOTAL SENSIBLE BTUH 23670.0 O.A.LATENT 20.0 CFM X .68 X 12 = 163.2 PEOPLE LATENT 2.0 PEOPLE X 205 = 410.0 GRAND TOTAL BTUH 24243.2 1600.8 SG FT /TON 0.98SHR 2.OTONS HEATING LOAD CALCULATIONS OUTSIDE TEMP 20 INSIDE TEMP 70 ROOF TRANSMISSION LOSS AREA U TD 3234 X .05 X 50 = 8085.0 SLAB LOSS 0 LF X 25 BTUH = 0.0 VENT. LOSS 20.0 CFM X 1.08 X 50 = 1085.0 SPACE HEAT LOSS = 9170.0 PICK -UP LOAD = 8085.0 TOTAL HEAT LOSS = 17255.0 1.6 WATTS /SO FT 5.1 KW CALCULATIONS FOR ZONE TLT-RMS REI-SOUTH-CTR ASHRAE CLTD /CLR COOLING LOAD CALCULATIONS PEAK MONTH - JUL OUTSIDE TEMP 84 LATITUDE 48 PEAK HOUR - 3PM INSIDE TEMP 75 INTERNAL GAINS AREA 460 SG FT BTUH I.F. W /ROOF PEOPLE 2.0 PEOPLE X 245 = 490.0 5.6 LIGHTS 552 WATTS X 3.413 X 100 % = 1884.0 MISC BTUH 0.0 TOTAL ROOM SENSIBLE BTUH 2374.0 PLENUM LIGHT HEAT AT 0 % 0.0 PLENUM ROOF HEAT AT 0 % 0.0 FAN MOTOR HEAT AT 8 % ROOM SENS. 189.9 VENT. 20.0 CFM X 1.08 X 9 = 195.3 TOTAL SENSIBLE BTUH 2759.2 O.A.LATENT 20.0 CFM X .68 X 12 = 163.2 PEOPLE LATENT 2.0 PEOPLE X 205 = 410.0 GRAND TOTAL BTUH 3332.4 1656.5 SC FT /TON 0.83SHR 0.3TONS HEATING LOAD CALCULATIONS OUTSIDE TEMP 20 INSIDE TEMP 70 SLAB LOSS 0 LF X 25 BTUH = 0.0 Z CC .le g N 0 07UU VENT. LOSS 20.0 CFM X 1.08 X 50 = 1085.0 W O SPACE HEAT LOSS = 1085.0 Q 2 Q PICK-UP LOAD = 1150.0 LL co : 3 d . TOTAL HEAT LOSS = 2235.0 1.4 WATTS /SG FT 0.7 KW W CALCULATIONS FOR ZONE LOCKERS REI-SOUTH -CTR ASHRAE CLTD /CLR COOLING LOAD CALCULATIONS PEAK MONTH - JUL OUTSIDE TEMP 84 PEAK HOUR - 3PM INSIDE TEMP 75 INTERNAL GAINS AREA 594 SO FT LATITUDE 48 BTUH I.F. W /ROOF PEOPLE 6.0 PEOPLE X 245 1470.0 10.6 LIGHTS 712.8 WATTS X 3.413 X 100 % = 2432.8 MISC BTUH 1800.0 TOTAL ROOM SENSIBLE BTUH 5702.8 PLENUM LIGHT HEAT AT 0 % 0.0 PLENUM ROOF HEAT AT 0 % 0.0 FAN MOTOR HEAT AT 8 % ROOM SENS. 456.2 VENT. 60.0 CFM X 1.08 X 9 = 585.9 TOTAL SENSIBLE BTUH 6744.9 O.A.LATENT 60.0 CFM X .68 X 12 = 489.6 PEOPLE LATENT 6.0 PEOPLE X 205 = 1230.0 GRAND TOTAL BTUH 8464.5 842.1 SO FT /TON 0.80SHR 0.7TONS HEATING LOAD CALCULATIONS OUTSIDE TEMP 20 INSIDE TEMP 70 SLAB LOSS 0 LF X 25 BTUH = 0.0 Z W � V ' UQ CO 00 W 00 LL VENT. LOSS 60.0 CFM X 1.08 X 50 = 3255.0 W 0 SPACE HEAT LOSS = 3255.0 2 PICK -UP LOAD = 1485.0 g J TOTAL HEAT LOSS = 4740.0 N C1 . 2.3 WATTS /SO FT 1.4 KW .LLJ Z HO Z I-- ill 111 D p V O -- 0 I- UU W '. H . 2! Z UU U = O ~. Z CALCULATIONS FOR ZONE OFFICE REI- SOUTH -CTR ASHRAE CLTD /CLR COOLING LOAD CALCULATIONS PEAK MONTH - JUL OUTSIDE TEMP 83 LATITUDE 48 PEAK HOUR - 5PM INSIDE TEMP 75 ROOF SOLAR AND TRANS GAIN AREA U TD 1034 X .05 X 62 X 100 % = 3205.4 INTERNAL GAINS AREA 1034 SO FT BTUH I.F. W /ROOF PEOPLE 8.3 PEOPLE X 245 = 2026.6 16.0 LIGHTS 1240.8 WATTS X 3.413 X 100 % = 4234.9 MISC BTUH 6352.3 TOTAL ROOM SENSIBLE BTUH 15819.2 PLENUM LIGHT HEAT AT 0 % 0.0 PLENUM ROOF HEAT AT 0 % 0.0 FAN MOTOR HEAT AT 8 % ROOM SENS. 1265.5 VENT. 82.7 CFM X 1.08 X 8 = 718.0 TOTAL SENSIBLE BTUH 17802.7 O.A.LATENT 82.7 CFM X .68 X 12 = 675.0 PEOPLE LATENT 8.3 PEOPLE X 205 = 1695.8 GRAND TOTAL BTUH 20173.5 615.1 SG FT /TON 0.88SHR 1.7TONS HEATING LOAD CALCULATIONS OUTSIDE TEMP 20 INSIDE TEMP 70 ROOF TRANSMISSION LOSS AREA U TD 1034 X .05 X 50 = 2585.0 SLAB LOSS 0 LF X 25 BTUH = 0.0 VENT. LOSS 82.7 CFM X 1.08 X 50 = 4487.6 SPACE HEAT LOSS = 7072.6 PICK-UP LOAD = 2585.0 TOTAL HEAT LOSS = 9657.6 2.7 WATTS /SO FT 2.8 KW ACTIVITY NUMBER: MO2 - 123 PROJECT NAME: REI Southcenter SITE ADDRESS: 230 Andover Pk West K Original Plan Submittal DATE: 06 -13 -02 Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPART /•214;e• Buildi NI Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 21 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP Fire Prevention AINL (p -W Structural Incomplete ❑ PERMIT COORD COPY Planning Division Permit Coordinator E DUE DATE: 06-18 -02 Not Applicable ❑ ❑ No further Review Required ❑ DUE DATE: 07 -16 -02 r ACTIVITY NUMBER: MO2 -123 PROJECT NAME: REI Southcenter SITE ADDRESS: 230 Andover Pk West DATE: 06 -13 -02 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete X Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TOES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review quire ❑ REVIEWER'S INITIALS: /o-r- APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions f k 1 1 Notation: lu, REVIEWER'S INITIALS: Documents/routing slip.doc 2-28.02 x n PLAN REVIEW /ROUTING SLIP Fire Prevention ``�'' Incomplete El Not Applicable = j, l h. ldt .&_i,. 54— a L Structural ' E ❑ Planning Division Permit Coordinator El ❑ DUE DATE: 06-18 -02 DATE: DUE DATE: 07 -16 -02 Not Approved (attach comments) ❑ DATE: 1/ Z'7iUZ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT NO.: I kDZ l 03 MECHANICAL PERMIT APPLICATIONS INSPECTIONS 2 Pre-construction WSEC Residential 60 WA Ventilation/Indoor AQC 610 Chimney Installation/All Types Vi 700 Framing 1080 Woodstove 1090 Smoke Detector Shut Off 1100 Rough -in Mechanical 1101 Mechanical Equipment/Controls 1102 Mechanical Pip/Duct Insul 1105 Underground Mech Rough -in 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final 4015 Special -Smoke Control System CONDITIONS • 10001 No changes to plans unless approved by Bldg Div off 10002 Plumbing permits shall be obtained through King Co • 10003 Electrical permits obtained through L & I 10005 All permits, imp records & approved plans available IS 10014 Readily accessible access to roof mounted equipment • 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans • 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & sPues ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: 1E FEES Basic Fee (YIN) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unii/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP/I ,750,000 Bill (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator - Domestic (qty) Incinerator - Comm/Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'I Fees - Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Plan Reviewer: /A-. Date: 6 7/2770 2 - Permit Tech: Date: 1 ACTIVITY NUMBER: MO2 -123 PROJECT NAME: REI Southcenter SITE ADDRESS: 230 Andover Pk West x DATE: 06 -13 -02 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ TUES /THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2.28 -02 CI PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete n Structural Review Required Planning Division ❑ Permit Coordinator No further Review Required DATE: ( i t).0/0 DUE DATE: 06-18 -02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: [i] REVIEWER'S INITIALS: DATE: DUE DATE: 07-16-02 Approved ❑ Approved with Conditions Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: F625 -O52 -0 (8/97) LICENSED AS PROVIDED- BY LAW AS ELEC CONTR.'HVAC /RFREXP. DATE LICENSE " #.• EC6A' :,::GBSYSI *000CM 002/14/2000 gFF'ECTIVE ; DATE ." :.: G, B SYSTEMS 7202 NE.'17 , ST ;,� •,:., KENMORE Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY REGIST . # EXP . DATE CCAACG GBSYSI *088BS 01/10/2005 EFFECTIVE DATE 01/10/1992 G B SYSTEMS INC 7202 NE 175TH ST KENMORE W 028 Please Remove And Sign Identification Card Before Placing In Billfold Signature Issued by DEPARTMENT Of- L BOR AND INDUSTRIES 1 vsNe . . 413.:A•i•*. • • • - .r 2 . '• E :.. .04 3`...EIS • - . . •• S 17.: S .. Bi Date Pe/rat -0 7-- , r, SEPARATE PERM:T P: FOR: I L - :....1HAP:CAL. I e:.TRICAL II UMBiNG i '-.S, Fa■-'ING CITY CF TUKWILA BUILD:kV; D:VISION r visioNs BE WADE r3 - WiTrkOVT PR-OR • .63 MO g3 MITHUN Architects. Desigr e^s.PlarneTs Pier 56 1201 Alaskan Wad Suite 200 Seartie, WA 98101 TE1 206 6233344 FAX 206 623 7005 fln L fl x - D 0 JUNE 10, 2002 PERMIT/BID SET 02284.00 COPYRIGHT c MITHUN, INC DUCT MOUNTED GRILLE LEGEND PLAN VIEW SECTION VIEW DESCRIPTION TYPE 22.5 GRILLE MOUNTED FOR H AL ORIZONT DISCHARGE DIFFUSION PATTERN AT 221.2 PATTERN UNLESS NOTED OTHERWISE u L..1 LAY IN RIFF LAY IN GRILLE SURFACE MT DIFF SURFACE MT RAG VARIES SUPPLY DUCT Ct GRILLE MOUNTED FOR DISCHARGE AT TO DEGREES BELOW HORIZONTAL MR DIFFUSION PATTERN AT 22Yt ° PATTERN UNLESS NOTED OTHERWISE Q __/ 30 °� 22.5 AIR DIFFUSION - 1/4 15/15 45 GRILLE MOUNTED VERTICAL DISCHARGE AIR DIFFUSION PATTERN AT 45. PATTERN UNLESS NOTED OTHERWISE 0 4 TOP RM 204 W_y DIFFUSER GRILLE SCHEDULE SYMBOL MANUFACTURER M SIZE TYPE COMMENTS (=4;- E OB CFME © C FME CFME S12E O CFM O CFM TUTUS MOD, TYPE 3 BORDER TITUS 50F, TYPE 3 BORDER TITUS 300RS, TYPE I BORDER TUTUS 350RL, TYPE 1 BORDER EXISTING DIFFUSER Ti TAR, CONCENTRIC ROUND AS NOTED AS NOTED AS NOTED AS NOTED AS NOTED AS NOTED LAY IN RIFF LAY IN GRILLE SURFACE MT DIFF SURFACE MT RAG VARIES SUPPLY SUPPLY, NOTES 1 RETURN,E'.HAUST,TRANSFER BALANCD DAMPER EXHAUST PER PLAN SUP,LY, NOTES 2.3 RETURN. TRANSFER, NOTE 4 FIELD VERIFY SIZE, LOCATION A PROPER TYPE FOR APPLICATION INSTALL IN POSITION /1 EXHAUST FAN SCHEDULE UNIT NO. SERVICE AND LOCATION GREENHECK MOOEL NO FAN TYPE CFM ESP (VOLT/ i , PHASE I RPM HP/ I BPD WATTS WT LBS NOTES EF - 1 LOUNGE /SHOWER GB-090 ROOFTOP -CENT. 900 11/4",120/1 1380 1/4 15/15 I, 5C 1,2,4 EF -2 TOP RM 204 SP -252 CABINET 400 1,'4'1120/1 -CO- 224 i INT'GL 37 1.3,6 EF -3 REPAIR SHOP :,8 -130 ROOFTOP -CENT. 1100 1 /2" 120/1 1090 1/4 16/16 70 1.2.5.7 - - 4000 - - 6061 - I - ! 1 . 2.3 ,4 1 SEISM .�_` BRACE PER JBC A:OLTREMEN 1NC PER SW 0,40E ,NES - 6 24 SL SA - Fr'pNG w ^'.:RN WANES EA ' S DE 0 ELEVATION AC -4 NC t: 4 "COLLAR t HIGH 't ANSmoN IEF -31 SEAL rl / BENCH COMPRESS SOUNDLININO 1/2" AROUND ,300 FRAME - / r -64'74 5. SA Or. 14eSu RvNST GN5 ANC OFFSETS -PER ELENA ^ON A -A BELOW 1 2"HIGH ■!- 3/4" x 34 SLOTS */CENTERLINES AT HOOD .3 ,E" AND 9" ABOVE BENCH SURFACE .B' OFFSE'� \. \ 36" LENGTH CENTER ON BENCH O SHOP BENCH HOOD NO SCALE SEE ROOFTOP EXHAUST FAN CURB DETAL 1/M -3 SL \ -140SM TRANS 15/15 SL `14aSM 14eSM TRANSITION TO 36/6 SM Fir BENCH HOOD. SEE DETAIL 2/M -1 LOCATE BOTTOM OF HOOD 2- MAXIMUM ABOVE BENCH VERIFY HEIGHT w /ARCHITECT O Z SHOP EXHAUST ELEVATION NO SCALE FAN BASE SIZE OD CURB SIZE FAN BASE - 1 1/2 FASTEN FAN CAP TO CURB I BOO SIZE `(2i. DUCT + 1 ° DUCT DO W'&4 CONSTANT - BRANC4 0•UC' CEN c - LNE E_EYAT EA S•:E MACH ExnnNIG A: - DUCT Eli iA' ON ROOF FASTEN DUCT FLANGE TO CURB ,_ __,--2X12 MINIMUM LEVEL ROOF CURB, CANT STRIP AND ROOFING TOR MAT ERIAL BY GENERAL CONTRAC FASTEN BOO TO CURB OR DUCT SOUNDL!NE D PEP w Aw RISER NOTE MECHANICAL CONTRACTOR COORDINATE CURB SIZE AND LOCATION WITH GENERAL CONTRACTOR. VERIFY CORRECT BDD SIZE AND FIT IN DUCT. mAPs FLOOR O EXHAUST FAN INSTALLATION DETAIL NO SCALE r I L_ CIENTEA. SIE wee APC SIZE REOLI ENEN S FOR SIDE DF DuC : oNIEC'106.5 OR MR BETWEEN ORaER'TATCAiS (SEE PLANS AN' WC' NOWT: GRILLE LEGO..:. OR OWEWITA SPIRAL )4JC7 CONCE/l E: SEA.AN'T AT DUG' /CAI. : ONNECTIO N SHEETMETAL CAN 0 DIFFUSER CAN /SPIRAL DUCT DETAIL NO SCALE NEW MR COND(T ONING jsr SCHEDULE &IN !Ste. CE I , NOM GAS 14A MBN• CFW ESP 1 F41, V ._ A EA/ F FC ?wr TNDTES AREA •a00E_ TOMS NPtiT o. T . •G , cry R ' v'0.'<ah AC - 4 EAST RETA T.`: 15 250 2C3 6000 iC 5 3 Tlsa .' s 464/3 , 46 2304' ' .2 ' • '. 6 AC - DOFF : C'T YH }6A+L T I 6C / 48 1 20“ y S _ 1 30C 12 5, 46C ' 3 9 , 60C ' _2 3 4 6 7 ' I 1 I , I I I I # �- -.I NOTES Rf C PRQ AC UNIT PER AGREEMTN' w''H TRANS, ME CNAN ICAS CONTRACTOR INSTAL. 2 FACTORY PROVIDE - 0 -1001 r00uLATIIVi ECO O+ ZER */INTEGRAL ENTHA CONTROL - 50X BARQETRIC RE IEF CAPACITY - TH*OUGH 'HE BASE ELECTRICAL AND GAS CON EC' 0N.5 - WITCHING ROOF CURB FIR DOW ..WIT WITH WOOL NAILING STRIPS - CT CONTROL INTERFACE FOR NOVAR CONTROLS - NON -BUSED DISCONNECT SIN•TCH - 120v/•a- CONVENIENCE OUTLET 3 HVAC CONTROLS BE GINNER PRON.OED AS PART OF THE INTEGRATED 51A 'cri GEAR TRANS SHALL FACTORY map.' AC A ' CO +'ROLLERS ANC CTI BOARDS THE W N CONTROLLER AND CON'.CL BOARDS *ILL BE FACTOR NDUNTED IN THE ELECTRICAL PANE_5 BY OTHERS ZONE TEMPERATURE SENSORS. OUTSIDE A:R TEMPERATURE SENSOR AND PUSH BUTTON OVERRIDE CONTROLLER SHALL BE NSTALLED AND *-RED BT ELECTRICAL CONTRACTOR 4 ELECTRICAL CONTRACTOR PROVIDE AND INSTALL POWER AIRE TO S NGLE PO NT CONNECTION 5 MECHAN CAL CONTRACTOR PROVIDE AND ,NSTALL SUPPLY DUCT SN,10KE DETECTOR ELECTRICAL CONTRACTOR PROVIDE AND .NSTALL POWER w RE ANC RELAY '0 FIRE CONTROL PANEL E. NE CHAN. CA_ CONTRACTOR INSTAL_ FACTORY PROVIDED ROOF CURBS ANC PROVIDE SEI9AIC RESTRAINT AS REOU,RED BY APPLICABLE CODE 7 FACTORY OPTION INCLUDES ' HP BELT DRIVE FAN MOTOR, BALANCE 'C 807 RPM FOR FLOY CONDITIONS IN SCHEDULE ABOVE NOTES EXISTING AC UNIT CONTRACTOR VERIFY PROPER FUNCTION IN ALL MODES OF OPERATION 2 MECHANICAL CONTRACTOR VERIFY CONSTANT FAN OPERATION AND VENTILATION DAMPERS OPEN DURING OCCUPIED NODE. OA DAMPER SHUT DOWN IN UNOCCUPIED MODE. 3 REBALANCE AC UNITS SER'V,NG REI TENANT AREAS T::: MATCH GRILLE AND C CFM'S AS NOTED ON SHEET 14-3 4 HVAC CONTROLS SHALL BE OWNER PROVIDED AS PART OF THE INTEGRATED SWITCH GEAR ELECTRICAL CONTRACTOR SHAL FIELD MOUNT AC UNIT CONTROLLERS AND CTI BOARDS. THE MAIN CONTROLLER AND CONTROL BOARDS WILL BE FIELD MOUNTED IN THE ELECTRICAL PANELS BY OTHERS ZONE TEMPERATURE SENSORS, OUTSIDE AIR TEMPERATURE SENSOR AND PUSH BUTTON OVERRIDE CONTROLLER SHALL BE INSTALLED AND WIRED BY THE ELECTRICAL CONTRACTOR NOTES 1. DISCONNECT BY ELECTRICAL CONTRACTOR. 2. FIELD INSTALL ADD PER DETAIL 1/1.4-3. 3 CONTROL CONTRACTOR PROVIDE LINE VOLTAGE THERMOSTATS TO ELECTRICAL CONTRACTOR FOR INSTALLATION. (60 -90F RANGE OF OPERATION). 4 CONTROL CONTRACTOR INTERLOCK EF -1 TO AC -11 OCCUPIED MODE OPERATION. 5 ELECTRICAL CONTRACTOR PROVIDE AND INSTALL WALL SWITCH ON /OFF CONTROL, 6. FACTORY OPTIONS INCLUDE ROUND DUCT CONNECTOR KIT. 7. FACTORY OPTIONS INCLUDE EXPLOSION PROOF MOTOR, SPARK PROOF RUB RING. NOTES, 1. FOR T -BAR CEILING. 2. DOUBLE DEFLECTION GRILLE FOR GYPSUM WALL BOARD ANC DUCT MOUNTED CANS 3. PROVIDE OPPOSED BLADE DAMPER UNLESS A MANUAL DAMPER IS SHOWN ON THE PLANS. 4. 3/4" BLADE SPACING AT 35 DEGREE ANGLE ABBV FULL NAME A AC AFF BOO BOO BOTT BTU BTUH BWG BWR CAP CFM COMB CONN DB DMPR DN EC ELEV ESP EXH FD FLA FOB FOT G GALV GC COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR BACKDRAFT DAAfER BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS BOTTOM WALL GRILLE BOTTOM WALL REGISTER CAPACITY CUBIC FEET PER MINUTE COMBUSTION CONNECT DUCT BOARD DAMPER DOWN EGGCRATE ELEVATION EXTERNAL STATIC PRESSURE EXHAUST FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP GAS LINE (LOW PRESSURE) GALVANIZED GENERAL CONTRACTOR HVAC ABBREVIATIONS ABBV FULL NAME GPM GALLONS PER MINUTE 14G HOT GAS LINE ID INSIDE DIMENSION MBH THOUSAND BTUH MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MIN MINIMUM PER HOUR MPG MEDIUM PRESSURE GAS MT MOUNT NOM NOMINAL OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER 00 OUTSIDE DIMENSION PO PRESSURE DROP RA RETURN AIR REG REGISTER (GRILLE WITH DAMPER) RED REQUIRED RIO ROUGH IN ONLY SA SUPPLY AIR SL SOUND LINING SM SHEET METAL SP STATIC PRESSURE SS STAINLESS STEEL TOO TOP OF DUCT TV TURN VANES TWG TOP WALL GRILLE TWR TOP WALL REGISTER TYP TYPICAL LINO UNLESS NOTED OTHERWISE MO.-/Z5 DUCT LEGEND ALL DUCT SIZES REFERENCE INSIDE DIMENSION (ADD INSULATION THICKNESS FOR 0.0.) DESCRIPTION SYMBOL RECTANGULAR SHEETMETAL - BARE SOUNDLINE SHEETMETAL (1 SHEETMETAL WRAPPED W /1W INSULATION SPIRAL ROUND SHEETMETAL - BARE POUND SHEETMETAL WRAPPED W /1Y:` INS. ROUND SM W /1'SPIRAL DUCT LINER FLEX DUCT SQUARE -TO -ROUND DUCT TRANSITION 14112 SM 14/12 SLSM 14/12 SMW I2•SM 126W 126 AC IH I I I I I I I I I I1 I I I I I I I I I I I I ITN ITII II I II HVAC GENERAL NOTES 1 THESE PLANS ARE SCNEWI' C ANC DC NOT SN40w E KACT ROUTING OR EVERY OFFSET M. p.• IM BE REOL REC THE HVAC ODNTRACTOR `- DOOR;,' '.ATE A TN ALL OTHER TRADES AND VER FY A__ CLEARA04ES BEFORE 9 DOING OP COMA •.0 . NG *OP. 2 MATER ! A S METHODS AND , NSTALLAT CA SHALL COMPL' WITH THE PR:p. , S 10145 DF THE ' 99 :1N 1 FORM NEC AN CA- CAE . 'HE '99' _h FORM MECHAN CAL CODE ANC THE 1998 WASHINGTON STAN E ENERGY CODE AND ALL OTHER APPLICABLE LOCAL CODES Aip ORDINANCES 3- DUCT CONSTRUCTION ANC HANGING 5HA__ :OYP_r * *H THE 1997 UMC AND * TH CU.'RENT SWCNA STANDARDS EARTHO.,A•E BRACE ALL DUCTS 24" 0•AME'ER ANC LARGER WHICH ARE TUSPENEEC BY HANGERS '2" OR uC : N LENGTH PROV EARTHOI.,AKE BRACING AT 30' ON CENTER 4Ax MLA/ FIBERGLASS DUC'BO.Rc SHALL NO' BE USED 4 ALL CONCEALED DUCT SYSTEMS SHALL BE SEALED W T.. LISTED MIASTIC TYPE DUCT SEA_ANT AT ALL JO,4TS SEAL FIT CON.__'.QN$ * "H DUCT SEALANT (NOT TAPE; EXPOSED DUCTS SHALL BE INTERNALLY SEALED 5 CONCEALED DUCTS SHA.- BE :NSULATEZ AS REQUIRED BY THE '998 WASHINGTON STATE ENERGY CODE - DUCT WRAP IN ROOF CEILING JOIST SPACE SHALL BE 3 5 ", 0 75 LB /CL FT FIBERGLASS DUCT I NSULA T ! ON W7 A FAC APP_ ED REINFORCED ALUM I NUM FC L VAPOR BARRIER - SOUND LINING IN DUCTS w 'HE BUILDING, SHALL BE 1`, 1 5 _8 /C_ FT FIBERGLASS DUCT LINING COATED TO PREVENT = BER EROSION AT VELOCITIES UP TC 4000 FPM - SOUND LINING, IN ROOFTOP DUCTS SHALL BE 2 5', 1 5 LB /CU F' FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 4000 FPM 6 FLEXIBLE DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" F BERGLASS INSULATION (R -5), ANC NON-PERFORATED iNTER:OF LINER W•TH WIRE HELIX DUCT SHA__ BE UL 18' LISTED CLASS , AIR DUCT F_ExIBLE DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED O HERWiSE IN ROOF CE;LiNG JOIST SPACE FLEX B_E DUCTS SHALL HAVE AN R -8 INSULATION RATING 7. PROVIDE EARTHQUAKE RESTRA NT FOR -'VAC EQL'PMENT IN ACCORDANCE WITH THE 1 997 UNIFORM BUILDING CODE AND PER LOCAL CODES AND ORDINANCES 8 PROVIDE TURN VANES IN ALL MITERED 90'S AND TEE'S, 9. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECTS, MEC- AN TO PRO'. 'DE ALL REDU.PEC MOTOR STARTERS AND OVERLOADS. SINGLE PHASE EXHAUST FANS SHALL BE EQUIPPED Ai'. THERMAL OVERLOAD PROTECTION A 10 DISPOSE OF ALL DEMOLISHED MATERIALS PER LOCAL CODES AND ORDINANCES 11. MAINTAIN 10' BETWEEN OUTSIDE AIR * TO AC UNITS FROM EXHAu ST FA. OUTLETS, PLUMB NG VENTS GAS FLUE OUTLETS 12 NEW EXPOSED DUCTS SHALL BE OF MIN 24 GA CONSTPJN. EXPOSED ROUND DUCTS SHALL BE SPIRAL WOUND SPECIAL PRECAUTIONS SHALL BE TAKEN TO PRCV' :DE FOR ACCEPTABLE APPEARANCE. EXPOSED DUCTS SHALL BE INTERNALLY SEA_ED AND SHA.' CIE FREE OF DEN'S AND BLEMISHES LABELS SMALL NCT TEC BE T APPLIED TO EXPOSED DUCTS FINAL APPROVAL OF EXPOSED DUCT ACCETANCE IS BY THE ARCHI 13 PROVIDE FIRE D'J.IPERS, SMOKE DAMPERS AND COMB NAT FIRE /SMOKE DAMPERS WHERE NDICATED ON PLANS AND AS REQUIRED BY SECTIONS 713 13 AND 71 3 '1 OF THE '997 UBC PRO LISTED FIRE STOPPING AT PENETRATIONS OF ASSEMBLIES ACCORDING TO SECTION 7 L ,)F HE 1997 UBC INSTALL FIRE DAMPERS AND CEIL,NG FIRE /SMOKE DAMPERS ,N AC.LOF.DANCE WITH THE MANUFACTURE'S INSTRUCTIONS, THE TERMS C= THE.P LISTING. AND THE RED IREv1ENTS OF THE CODE 14 1AECH'N :CAL CONTRACTOR SHALL PROVIDE AND MOUNT RETURN DUCT SMOKE DETECTORS FOR AUTOMAT C SHOT DOWN OF ALL HEATILS DA COOLING EOU.PMENT DELIVER:bG IN EXCESS OF 2000 CAM IN ACCORDANCE WITH SECTION 6C6 THE '998 IMO POWER WRING AND NTERLOCK WIRING WITH THE BUILDING FIRE ALARV SYSTEM IS BY THE ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL PROVIDE WEATHER 'ROOF ENCLOSURES FOR DUCT SMOKE DETECTORS WHERE NECESSARY ON ROOD DUCT SYSTEM. COORD NATE W/ ELECTRICAL CONTRACTOR THE MECHANICAL SCOPE OF WORK INCLUDES, BL" S NO L;M TEC TC THE FOLLOWING ITEMS LISTED BELOW, AS WELL AS THE INFORMATION PRESENTED IN THESE °L.ANS AND THE PROJECT SPECIFICATIONS. 1 MECHANICAL CONTRACTOR VERI =Y FIELD CONCIT ONS AND , NDICATE N WRITING TO THE ARCHITECT ANY CONDITIONS WHICH INTERFERE WITH CONSTRLCT!ON PER THESE PLANS AND SPECIFICATIONS. 2. PERFORM OR COORDINATE DEMOLITION WORK AS DESLPIBED ON SHEET M-2. DISPOSE OF ALL DEMO'D EQUIPMENT AND MATERIALS PER LOCAL CODES AND ORLINANCES. 3. INSTALL AC UNITS AC -4 AND AC -5 PER SHEET M-3 COORDINATE ROOF CURB LOCATION AND ROOF WORK WITH GENERAL CONTRACTOR AND ROOFING CONTRACTOR INSTALL NEW DUCTWORK AND GRDs PER SHEET M-3. PROVIDE AND INSTALL TRANSFER GRILLES ANC BAROMETRIC rELIEF CAPS PER SHEET M-3. 4 BALANCE ALL NEW ANC EXISTING UNIT SUPPLY AIR AND OUTSIDE AIR FLOWS PER THE VALUES SHOWN ON THE AC UNIT SCHEDULE ON SHEET M-1 AND PER THE PLAN ON SHEET M-3 5. INSTALL REPAIR SHOP AND REI OFFICE AREA EXHAUST FANS (EF- 1,2,3) AND ASSOCIATED DUCTWORK GRD'S AND TRANSFER GRILLES AS INDICATED ON THE PLANS. 6. REPLACE EXISTING AC UNIT THERMOSTATS WITH NEW NOVAR CONTROL SYSTEM DETAILD IN THE PLANS AND SPECIFICATIONS. VERIFY PROPER HEATING AND COOLING STAGING OPERATION INCLUDING ECONOMIZER MODULATION AND OPERATION. ELECTRICAL CONTRACTOR PROVIDES AND INSTALLS NOVER CONTROLS. MECHANICAL CONTRACTOR COORDINATE AND VERIFY PROPER UNIT OPERATION AFTER INSTALLATION MANUAL DAMPER (MD) DAMPER LEGEND MOTORIZED CONTROL DAMPER (CD) HORIZONTAL COMB. FIRE /SMOKE DAMPER (HFSD) UL LISTED 555S, 1-1/2 HR. CLASS II LEAKAGE REMODEL SCOPE OF WORK VERTICAL COMB. FIRE /SMOKE DAMPER (FSD) 1„ • - - UL USTED 5555. 1-1/2 HR. CLASS II LEAKAGE II ISM 1 'A4' CaVv ,.4,Yf�. I. T :r. PERMIT CENTEP 1 MITHUN Arch :tects.Oes.grlers. Planners Pier 56 1201 Alast.r. Way Suite 200 Seattle. WA 98101 TEi 206 62 3 3344 FAX 206 623.7005 SMC `()( N1) \IE( LANI( _al_ coNsl - 1.T1m. HMI3 !R 4., PJ 4 sillIV'.H_ •..4. PA salt rPOI, TIa -1.142 BG SS IG IG SMM AU. 02284.00 JUNE 10, 2002 _HVAC NOTES, LEGENDS SCHEDULES & DETAILS SMC -066 M EN 1 C.D. SET COPYRIGHT © 2002 MITHUN EXISTING AIR CONDITIONING UNIT SCHEDULE (FOR REFERENCE ONLY) UN, ' NC SERVICE 14F'GR A AREA I EL NOM TONS GAS NEAT MBH 1 NOM 'ESP FAN & ; v-OA JEER/ I ELECTR ISA. WT 1Nq'ES LBS . !PUT OUTPUT, CFM , If 1 CFM ii SEERi VOLT /P MCA AC.1 W RETAIL 15 -- -- 6000 _ - 1 a004 I - - - ' AC 2 RETAIL INTERIOR 6 - -- 2400 - 400, - ■ - - 2 ,3. 4 AC.3 BACK OF STORE f 10 - - 4000 - - 6061 - I - ! 1 . 2.3 ,4 SEISM .�_` BRACE PER JBC A:OLTREMEN 1NC PER SW 0,40E ,NES - 6 24 SL SA - Fr'pNG w ^'.:RN WANES EA ' S DE 0 ELEVATION AC -4 NC t: 4 "COLLAR t HIGH 't ANSmoN IEF -31 SEAL rl / BENCH COMPRESS SOUNDLININO 1/2" AROUND ,300 FRAME - / r -64'74 5. SA Or. 14eSu RvNST GN5 ANC OFFSETS -PER ELENA ^ON A -A BELOW 1 2"HIGH ■!- 3/4" x 34 SLOTS */CENTERLINES AT HOOD .3 ,E" AND 9" ABOVE BENCH SURFACE .B' OFFSE'� \. \ 36" LENGTH CENTER ON BENCH O SHOP BENCH HOOD NO SCALE SEE ROOFTOP EXHAUST FAN CURB DETAL 1/M -3 SL \ -140SM TRANS 15/15 SL `14aSM 14eSM TRANSITION TO 36/6 SM Fir BENCH HOOD. SEE DETAIL 2/M -1 LOCATE BOTTOM OF HOOD 2- MAXIMUM ABOVE BENCH VERIFY HEIGHT w /ARCHITECT O Z SHOP EXHAUST ELEVATION NO SCALE FAN BASE SIZE OD CURB SIZE FAN BASE - 1 1/2 FASTEN FAN CAP TO CURB I BOO SIZE `(2i. DUCT + 1 ° DUCT DO W'&4 CONSTANT - BRANC4 0•UC' CEN c - LNE E_EYAT EA S•:E MACH ExnnNIG A: - DUCT Eli iA' ON ROOF FASTEN DUCT FLANGE TO CURB ,_ __,--2X12 MINIMUM LEVEL ROOF CURB, CANT STRIP AND ROOFING TOR MAT ERIAL BY GENERAL CONTRAC FASTEN BOO TO CURB OR DUCT SOUNDL!NE D PEP w Aw RISER NOTE MECHANICAL CONTRACTOR COORDINATE CURB SIZE AND LOCATION WITH GENERAL CONTRACTOR. VERIFY CORRECT BDD SIZE AND FIT IN DUCT. mAPs FLOOR O EXHAUST FAN INSTALLATION DETAIL NO SCALE r I L_ CIENTEA. SIE wee APC SIZE REOLI ENEN S FOR SIDE DF DuC : oNIEC'106.5 OR MR BETWEEN ORaER'TATCAiS (SEE PLANS AN' WC' NOWT: GRILLE LEGO..:. OR OWEWITA SPIRAL )4JC7 CONCE/l E: SEA.AN'T AT DUG' /CAI. : ONNECTIO N SHEETMETAL CAN 0 DIFFUSER CAN /SPIRAL DUCT DETAIL NO SCALE NEW MR COND(T ONING jsr SCHEDULE &IN !Ste. CE I , NOM GAS 14A MBN• CFW ESP 1 F41, V ._ A EA/ F FC ?wr TNDTES AREA •a00E_ TOMS NPtiT o. T . •G , cry R ' v'0.'<ah AC - 4 EAST RETA T.`: 15 250 2C3 6000 iC 5 3 Tlsa .' s 464/3 , 46 2304' ' .2 ' • '. 6 AC - DOFF : C'T YH }6A+L T I 6C / 48 1 20“ y S _ 1 30C 12 5, 46C ' 3 9 , 60C ' _2 3 4 6 7 ' I 1 I , I I I I # �- -.I NOTES Rf C PRQ AC UNIT PER AGREEMTN' w''H TRANS, ME CNAN ICAS CONTRACTOR INSTAL. 2 FACTORY PROVIDE - 0 -1001 r00uLATIIVi ECO O+ ZER */INTEGRAL ENTHA CONTROL - 50X BARQETRIC RE IEF CAPACITY - TH*OUGH 'HE BASE ELECTRICAL AND GAS CON EC' 0N.5 - WITCHING ROOF CURB FIR DOW ..WIT WITH WOOL NAILING STRIPS - CT CONTROL INTERFACE FOR NOVAR CONTROLS - NON -BUSED DISCONNECT SIN•TCH - 120v/•a- CONVENIENCE OUTLET 3 HVAC CONTROLS BE GINNER PRON.OED AS PART OF THE INTEGRATED 51A 'cri GEAR TRANS SHALL FACTORY map.' AC A ' CO +'ROLLERS ANC CTI BOARDS THE W N CONTROLLER AND CON'.CL BOARDS *ILL BE FACTOR NDUNTED IN THE ELECTRICAL PANE_5 BY OTHERS ZONE TEMPERATURE SENSORS. OUTSIDE A:R TEMPERATURE SENSOR AND PUSH BUTTON OVERRIDE CONTROLLER SHALL BE NSTALLED AND *-RED BT ELECTRICAL CONTRACTOR 4 ELECTRICAL CONTRACTOR PROVIDE AND INSTALL POWER AIRE TO S NGLE PO NT CONNECTION 5 MECHAN CAL CONTRACTOR PROVIDE AND ,NSTALL SUPPLY DUCT SN,10KE DETECTOR ELECTRICAL CONTRACTOR PROVIDE AND .NSTALL POWER w RE ANC RELAY '0 FIRE CONTROL PANEL E. NE CHAN. CA_ CONTRACTOR INSTAL_ FACTORY PROVIDED ROOF CURBS ANC PROVIDE SEI9AIC RESTRAINT AS REOU,RED BY APPLICABLE CODE 7 FACTORY OPTION INCLUDES ' HP BELT DRIVE FAN MOTOR, BALANCE 'C 807 RPM FOR FLOY CONDITIONS IN SCHEDULE ABOVE NOTES EXISTING AC UNIT CONTRACTOR VERIFY PROPER FUNCTION IN ALL MODES OF OPERATION 2 MECHANICAL CONTRACTOR VERIFY CONSTANT FAN OPERATION AND VENTILATION DAMPERS OPEN DURING OCCUPIED NODE. OA DAMPER SHUT DOWN IN UNOCCUPIED MODE. 3 REBALANCE AC UNITS SER'V,NG REI TENANT AREAS T::: MATCH GRILLE AND C CFM'S AS NOTED ON SHEET 14-3 4 HVAC CONTROLS SHALL BE OWNER PROVIDED AS PART OF THE INTEGRATED SWITCH GEAR ELECTRICAL CONTRACTOR SHAL FIELD MOUNT AC UNIT CONTROLLERS AND CTI BOARDS. THE MAIN CONTROLLER AND CONTROL BOARDS WILL BE FIELD MOUNTED IN THE ELECTRICAL PANELS BY OTHERS ZONE TEMPERATURE SENSORS, OUTSIDE AIR TEMPERATURE SENSOR AND PUSH BUTTON OVERRIDE CONTROLLER SHALL BE INSTALLED AND WIRED BY THE ELECTRICAL CONTRACTOR NOTES 1. DISCONNECT BY ELECTRICAL CONTRACTOR. 2. FIELD INSTALL ADD PER DETAIL 1/1.4-3. 3 CONTROL CONTRACTOR PROVIDE LINE VOLTAGE THERMOSTATS TO ELECTRICAL CONTRACTOR FOR INSTALLATION. (60 -90F RANGE OF OPERATION). 4 CONTROL CONTRACTOR INTERLOCK EF -1 TO AC -11 OCCUPIED MODE OPERATION. 5 ELECTRICAL CONTRACTOR PROVIDE AND INSTALL WALL SWITCH ON /OFF CONTROL, 6. FACTORY OPTIONS INCLUDE ROUND DUCT CONNECTOR KIT. 7. FACTORY OPTIONS INCLUDE EXPLOSION PROOF MOTOR, SPARK PROOF RUB RING. NOTES, 1. FOR T -BAR CEILING. 2. DOUBLE DEFLECTION GRILLE FOR GYPSUM WALL BOARD ANC DUCT MOUNTED CANS 3. PROVIDE OPPOSED BLADE DAMPER UNLESS A MANUAL DAMPER IS SHOWN ON THE PLANS. 4. 3/4" BLADE SPACING AT 35 DEGREE ANGLE ABBV FULL NAME A AC AFF BOO BOO BOTT BTU BTUH BWG BWR CAP CFM COMB CONN DB DMPR DN EC ELEV ESP EXH FD FLA FOB FOT G GALV GC COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR BACKDRAFT DAAfER BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS BOTTOM WALL GRILLE BOTTOM WALL REGISTER CAPACITY CUBIC FEET PER MINUTE COMBUSTION CONNECT DUCT BOARD DAMPER DOWN EGGCRATE ELEVATION EXTERNAL STATIC PRESSURE EXHAUST FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP GAS LINE (LOW PRESSURE) GALVANIZED GENERAL CONTRACTOR HVAC ABBREVIATIONS ABBV FULL NAME GPM GALLONS PER MINUTE 14G HOT GAS LINE ID INSIDE DIMENSION MBH THOUSAND BTUH MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MIN MINIMUM PER HOUR MPG MEDIUM PRESSURE GAS MT MOUNT NOM NOMINAL OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER 00 OUTSIDE DIMENSION PO PRESSURE DROP RA RETURN AIR REG REGISTER (GRILLE WITH DAMPER) RED REQUIRED RIO ROUGH IN ONLY SA SUPPLY AIR SL SOUND LINING SM SHEET METAL SP STATIC PRESSURE SS STAINLESS STEEL TOO TOP OF DUCT TV TURN VANES TWG TOP WALL GRILLE TWR TOP WALL REGISTER TYP TYPICAL LINO UNLESS NOTED OTHERWISE MO.-/Z5 DUCT LEGEND ALL DUCT SIZES REFERENCE INSIDE DIMENSION (ADD INSULATION THICKNESS FOR 0.0.) DESCRIPTION SYMBOL RECTANGULAR SHEETMETAL - BARE SOUNDLINE SHEETMETAL (1 SHEETMETAL WRAPPED W /1W INSULATION SPIRAL ROUND SHEETMETAL - BARE POUND SHEETMETAL WRAPPED W /1Y:` INS. ROUND SM W /1'SPIRAL DUCT LINER FLEX DUCT SQUARE -TO -ROUND DUCT TRANSITION 14112 SM 14/12 SLSM 14/12 SMW I2•SM 126W 126 AC IH I I I I I I I I I I1 I I I I I I I I I I I I ITN ITII II I II HVAC GENERAL NOTES 1 THESE PLANS ARE SCNEWI' C ANC DC NOT SN40w E KACT ROUTING OR EVERY OFFSET M. p.• IM BE REOL REC THE HVAC ODNTRACTOR `- DOOR;,' '.ATE A TN ALL OTHER TRADES AND VER FY A__ CLEARA04ES BEFORE 9 DOING OP COMA •.0 . NG *OP. 2 MATER ! A S METHODS AND , NSTALLAT CA SHALL COMPL' WITH THE PR:p. , S 10145 DF THE ' 99 :1N 1 FORM NEC AN CA- CAE . 'HE '99' _h FORM MECHAN CAL CODE ANC THE 1998 WASHINGTON STAN E ENERGY CODE AND ALL OTHER APPLICABLE LOCAL CODES Aip ORDINANCES 3- DUCT CONSTRUCTION ANC HANGING 5HA__ :OYP_r * *H THE 1997 UMC AND * TH CU.'RENT SWCNA STANDARDS EARTHO.,A•E BRACE ALL DUCTS 24" 0•AME'ER ANC LARGER WHICH ARE TUSPENEEC BY HANGERS '2" OR uC : N LENGTH PROV EARTHOI.,AKE BRACING AT 30' ON CENTER 4Ax MLA/ FIBERGLASS DUC'BO.Rc SHALL NO' BE USED 4 ALL CONCEALED DUCT SYSTEMS SHALL BE SEALED W T.. LISTED MIASTIC TYPE DUCT SEA_ANT AT ALL JO,4TS SEAL FIT CON.__'.QN$ * "H DUCT SEALANT (NOT TAPE; EXPOSED DUCTS SHALL BE INTERNALLY SEALED 5 CONCEALED DUCTS SHA.- BE :NSULATEZ AS REQUIRED BY THE '998 WASHINGTON STATE ENERGY CODE - DUCT WRAP IN ROOF CEILING JOIST SPACE SHALL BE 3 5 ", 0 75 LB /CL FT FIBERGLASS DUCT I NSULA T ! ON W7 A FAC APP_ ED REINFORCED ALUM I NUM FC L VAPOR BARRIER - SOUND LINING IN DUCTS w 'HE BUILDING, SHALL BE 1`, 1 5 _8 /C_ FT FIBERGLASS DUCT LINING COATED TO PREVENT = BER EROSION AT VELOCITIES UP TC 4000 FPM - SOUND LINING, IN ROOFTOP DUCTS SHALL BE 2 5', 1 5 LB /CU F' FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 4000 FPM 6 FLEXIBLE DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" F BERGLASS INSULATION (R -5), ANC NON-PERFORATED iNTER:OF LINER W•TH WIRE HELIX DUCT SHA__ BE UL 18' LISTED CLASS , AIR DUCT F_ExIBLE DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED O HERWiSE IN ROOF CE;LiNG JOIST SPACE FLEX B_E DUCTS SHALL HAVE AN R -8 INSULATION RATING 7. PROVIDE EARTHQUAKE RESTRA NT FOR -'VAC EQL'PMENT IN ACCORDANCE WITH THE 1 997 UNIFORM BUILDING CODE AND PER LOCAL CODES AND ORDINANCES 8 PROVIDE TURN VANES IN ALL MITERED 90'S AND TEE'S, 9. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECTS, MEC- AN TO PRO'. 'DE ALL REDU.PEC MOTOR STARTERS AND OVERLOADS. SINGLE PHASE EXHAUST FANS SHALL BE EQUIPPED Ai'. THERMAL OVERLOAD PROTECTION A 10 DISPOSE OF ALL DEMOLISHED MATERIALS PER LOCAL CODES AND ORDINANCES 11. MAINTAIN 10' BETWEEN OUTSIDE AIR * TO AC UNITS FROM EXHAu ST FA. OUTLETS, PLUMB NG VENTS GAS FLUE OUTLETS 12 NEW EXPOSED DUCTS SHALL BE OF MIN 24 GA CONSTPJN. EXPOSED ROUND DUCTS SHALL BE SPIRAL WOUND SPECIAL PRECAUTIONS SHALL BE TAKEN TO PRCV' :DE FOR ACCEPTABLE APPEARANCE. EXPOSED DUCTS SHALL BE INTERNALLY SEA_ED AND SHA.' CIE FREE OF DEN'S AND BLEMISHES LABELS SMALL NCT TEC BE T APPLIED TO EXPOSED DUCTS FINAL APPROVAL OF EXPOSED DUCT ACCETANCE IS BY THE ARCHI 13 PROVIDE FIRE D'J.IPERS, SMOKE DAMPERS AND COMB NAT FIRE /SMOKE DAMPERS WHERE NDICATED ON PLANS AND AS REQUIRED BY SECTIONS 713 13 AND 71 3 '1 OF THE '997 UBC PRO LISTED FIRE STOPPING AT PENETRATIONS OF ASSEMBLIES ACCORDING TO SECTION 7 L ,)F HE 1997 UBC INSTALL FIRE DAMPERS AND CEIL,NG FIRE /SMOKE DAMPERS ,N AC.LOF.DANCE WITH THE MANUFACTURE'S INSTRUCTIONS, THE TERMS C= THE.P LISTING. AND THE RED IREv1ENTS OF THE CODE 14 1AECH'N :CAL CONTRACTOR SHALL PROVIDE AND MOUNT RETURN DUCT SMOKE DETECTORS FOR AUTOMAT C SHOT DOWN OF ALL HEATILS DA COOLING EOU.PMENT DELIVER:bG IN EXCESS OF 2000 CAM IN ACCORDANCE WITH SECTION 6C6 THE '998 IMO POWER WRING AND NTERLOCK WIRING WITH THE BUILDING FIRE ALARV SYSTEM IS BY THE ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL PROVIDE WEATHER 'ROOF ENCLOSURES FOR DUCT SMOKE DETECTORS WHERE NECESSARY ON ROOD DUCT SYSTEM. COORD NATE W/ ELECTRICAL CONTRACTOR THE MECHANICAL SCOPE OF WORK INCLUDES, BL" S NO L;M TEC TC THE FOLLOWING ITEMS LISTED BELOW, AS WELL AS THE INFORMATION PRESENTED IN THESE °L.ANS AND THE PROJECT SPECIFICATIONS. 1 MECHANICAL CONTRACTOR VERI =Y FIELD CONCIT ONS AND , NDICATE N WRITING TO THE ARCHITECT ANY CONDITIONS WHICH INTERFERE WITH CONSTRLCT!ON PER THESE PLANS AND SPECIFICATIONS. 2. PERFORM OR COORDINATE DEMOLITION WORK AS DESLPIBED ON SHEET M-2. DISPOSE OF ALL DEMO'D EQUIPMENT AND MATERIALS PER LOCAL CODES AND ORLINANCES. 3. INSTALL AC UNITS AC -4 AND AC -5 PER SHEET M-3 COORDINATE ROOF CURB LOCATION AND ROOF WORK WITH GENERAL CONTRACTOR AND ROOFING CONTRACTOR INSTALL NEW DUCTWORK AND GRDs PER SHEET M-3. PROVIDE AND INSTALL TRANSFER GRILLES ANC BAROMETRIC rELIEF CAPS PER SHEET M-3. 4 BALANCE ALL NEW ANC EXISTING UNIT SUPPLY AIR AND OUTSIDE AIR FLOWS PER THE VALUES SHOWN ON THE AC UNIT SCHEDULE ON SHEET M-1 AND PER THE PLAN ON SHEET M-3 5. INSTALL REPAIR SHOP AND REI OFFICE AREA EXHAUST FANS (EF- 1,2,3) AND ASSOCIATED DUCTWORK GRD'S AND TRANSFER GRILLES AS INDICATED ON THE PLANS. 6. REPLACE EXISTING AC UNIT THERMOSTATS WITH NEW NOVAR CONTROL SYSTEM DETAILD IN THE PLANS AND SPECIFICATIONS. VERIFY PROPER HEATING AND COOLING STAGING OPERATION INCLUDING ECONOMIZER MODULATION AND OPERATION. ELECTRICAL CONTRACTOR PROVIDES AND INSTALLS NOVER CONTROLS. MECHANICAL CONTRACTOR COORDINATE AND VERIFY PROPER UNIT OPERATION AFTER INSTALLATION MANUAL DAMPER (MD) DAMPER LEGEND MOTORIZED CONTROL DAMPER (CD) HORIZONTAL COMB. FIRE /SMOKE DAMPER (HFSD) UL LISTED 555S, 1-1/2 HR. CLASS II LEAKAGE REMODEL SCOPE OF WORK VERTICAL COMB. FIRE /SMOKE DAMPER (FSD) 1„ • - - UL USTED 5555. 1-1/2 HR. CLASS II LEAKAGE II ISM 1 'A4' CaVv ,.4,Yf�. I. T :r. PERMIT CENTEP 1 MITHUN Arch :tects.Oes.grlers. Planners Pier 56 1201 Alast.r. Way Suite 200 Seattle. WA 98101 TEi 206 62 3 3344 FAX 206 623.7005 SMC `()( N1) \IE( LANI( _al_ coNsl - 1.T1m. HMI3 !R 4., PJ 4 sillIV'.H_ •..4. PA salt rPOI, TIa -1.142 BG SS IG IG SMM AU. 02284.00 JUNE 10, 2002 _HVAC NOTES, LEGENDS SCHEDULES & DETAILS SMC -066 M EN 1 C.D. SET COPYRIGHT © 2002 MITHUN • J D E EXISTING Ac - MAINTAIN DUCTING AS IS - DEMO TSTAT & WIRE DEMOLITION PLAN SCALE" 1 /8" = 1 '0" DINOLITION NOTES' THESE DEMOLMON PLANS WERE MADE WITH LIMITED ACCESS AND AS-BUILT INFORmATioN. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS ANC EXAMINE THE REMODEL PLANS TO UNDERSTAND DEMOLMON INTENT PRIOR TO BID OR START OF DEMOLITION. DUCTWORK DEr.40LiTION INCLUDES CONNECTED ORD's. BRANCH AND FLEX DUCTS. DUCTWORK AND ACCESSORIES MAY BE SALVAGED AND REUSED PENDING PROPER SIZE, SHAPE AND APPROVAL BY ARCHITECT. — I I EXISTING AC-2 MAINTAIN DUCTING AS .5 - DEMO TSTAT & WIRE F G H J DEMO PLumaiNG AND HVAC SYSTEMS IN THIS AREA CAP ALL WATER, VENT AND WASTE LINES IN WALL AND FLOOR PENETRATIONS MAJN 0* SuPL SERVING Az..‘. TENAK mANTAiN CW SUPPLY SERVING ADJACENT TENANT MAINTAIN CW SUPPLY SERVING ADJACENT TENANT DEMO DEMO TRANSFER TRANSFER GRILLES GRILLES EXISTING AC-3 I COORDINATE DEMO OF FIRE RISER A BRANCH LINE BY SPRINKLER CONTRACTOR CAP AT SUPPLY LINE CONN.-- --4 . 1 CONCENTRIC SUPPLY AND RETURN _J UNIT. MAINTAIN SA A RA RISERS —DEMO SA DUCT ,n2../2 0 2 21 3 4 5 6 TTVM I', EN TEI MITHUN Arc!' dects.Des,gnets- ne• s Poet s6 1201 Alaskan Way Suite 200 Seattle WA 98' co 206 623 33,44 Fax 206 623 7005 S M C )1 I) ME( - 1! . CON !.TI N (,• • K4 74, fat Amif L[i BC, O WN, SO MAW S S 011PEC, G P ROJECT DOMED I G MAIN BM cut. 02284.00 JUNE 10, 2002 AT HVAC AND PLUMBING DEMOLITION PLAN SMC-066 M 2 PERMIT/ BID SET COPYHIL,H1 '4 MITHUN rAS "EN 4_ 94 • r4,rA1E Tc CARP • • - „'2' =A&. € ARC •-''- -90A. 'S - ' A" EA: F_Asr _i;L rMl,; AC S-RtP Are. v t C CLQ %S r, A! : C1e V' vE+ERA_ 'CON 'a AC" OR R^c: N w - _ - •A_ s. A.0 4,4 CA`. ST"; :P BY GENERA_ CON'RA_ OR FAN EASE SIZE OD C_RB SIZE 'AN BASE - 1 1/2 RC3 OFNG CURE s SQE ROOF : ECx -' LA,. SuPPCPT - 9 :T.+ERS I Q ROOF CURB INSTALLATION DETAIL •.D SCALE GREENHECK 60/30 BAROMETR RELIEF HOC: INS - ALL •4000 ANGLE SUP°OPT FAS "ENERS W""- WING N UTS FOP ACCESS TO OAUPER BY OPENING DAP A.0NG BOLT AXIS_ BALANCE '!E" DNS ALLLED 66 .3.' RELIEF DAMPED - C 0.04' BUILDING POSIT'4E PRESS,. RE USE RUSKIN COUNTER BALANCED DAMPER /CB; -4 2x1: MINIM AC Uw / I j - ..E./EL ROOF CURE, CANT STRIP AND POOcING — MA cR,A, B' GENERA._ CDNTRAC OR BOLT AND SEAL RE"AJMNG FLANGE TO CURB 0 BAROMETRIC RELIEF CAP DETAIL NC SCALE A; • C.Far ANC FACTOR wAS3 °RCA DE7 BY RE AK I NS' ED 81' AE _HA, CA_ ::ONTRAC A B 102 10 TYPICAL CASs 101 SER'. __ F 10 AC-1 0 , / I EXISTING AC -1 I' \ I 15 TONS, 6000 CFM -{ r - MAINTAIN AS IS. REBALANCE PER EXISTING AC SCHEDULE - " - AND PER THIS PLAN. • RET 1a_ I in RE TA I L!r ifwr_ D G H MEZZANINE FLOOR PLAN SCALE' - / 8' = 1'0' o 1BoSM MAPS/ 1300 �_ Lm-- 180SM AC -2 E I I I I H ii MAIN FLOOR PLAN SCALE' 1/8" = 1'0" . 0.106A4 220 SM 220Su -0 - - - — EXISTING AC -2 6 TONS, 2400 CFM MAINTAIN AS IS. REBALANCE PER EXSTG AC SCHEDULE RE TA ,_ Iu DUCT MOUNTED SUPPLY GRILLE - TYPICAL SEE DUCT /GRILLE LEGEND & DETAIL 5 ON SHEET M -1 RE �e 11e; RE =_ Lam__ PAC-4 L SEE ROOF CURB IETAIL 1/M -3 AND 1/M -1 1I 0 1' C 1 1 J 26/64 SL SA DN 18/70 SL RA DN USE 'V'S AT ELBOWS 18/70 SL RA W /OPNG AT TOP. 8' MIN FM ELBOW. AC -3 r 24/12 SL TRANSFER DUCT. 48" - MIN. LENGTH WITH 1 2/24 OPNGS ON TOP AT INLET AND ON BOTTOM AT OUTLET. DUCT DOWN TO SHOP CEILING GRILLE. LOCATE UNIT OUT OF VIEW ABOVE CEILING GREENNECK FABRW -000 30/60 ROOFTOP BAROMETRIC RELIEF CAP SEE CT. 2/u -3 2 TYPICAL q5; : t`)0 BETA. I 11e REPAIR SHOP Elkfl 04454g ©406CF1. I I EF -31 - EXISTING AC -3 CONVERT T O DUC SUPPLY AND RETURN - EXTEND FULL SIZE DUCTS DOWN - TRANS. SA '0 24 MINIMUM _ '�- 14/14 SL DN TO HOOD 14/14 SL UP TO EF -3 I SEE DETAILS 2,3/m- tar COORDINATE MODIFICATIONS CLG W /GC FRAMING _. . . ON ROOF SEE DETAIL 4/IA- 1 M)2--/2 3 21 3 4 5 2 6 T;!K`.VILA °ERMIT CENT E. MITHUN ,Arcr=. sects• Designers. Planne+s Pte+ 56 1201 Aiaskan Way S,kte 20C Seattle. WA 98 * o1 TO' 2:.)6 623 3344 ‚Al 2 0E 623.7005 SMC ME( HAM( _a C ON:'. L":[\G 7033 •} 3tt .age ru .tasr Tits -s�._ BG SS , IG ▪ ;NE, IG BM HVAC FLOOR PLANS 02284.00 JUNE 10. 2002 M -3 2 SMC -066 PERMIT/ BID SET COPYRIGHT ® 2002 MITHUN