Loading...
HomeMy WebLinkAboutPermit M02-154 - KING COUNTY METRO• KC METRO SOUTH 11971 EAST MARGINAL WAY SOUTH M02 -154 U,:..)a'_- v:n:: ;f:ti +'.nif itul =a.e :.fA:iV'Yii `x::ilin r.+ JRti: 4 .151,'i4dtiul ?�;:.kn:tS;e.i��.. Parcel No.: 1023049066 Permit Number: MO2 -154 Address: 11911 EAST MARGINAL WY S TUKW Issue Date: 08/06/2002 Suite No: Permit Expires On: 02/02/2003 Tenant: Name: KING COUNTY METRO Address: 11911 EAST MARGINAL WY S, TUKWILA WA Owner: Name: KING COUNTY Address: 500 4TH AVE #500, SEATTLE WA Contact Person: Name: SCOTT RAEDER Phone: 253 942 -7028 Address: 1112 SOUTH 344TH, SUITE #303, FEDERAL WAY, WA 98003 Contractor: Name: AIRE PRO INC Address: 1112 S 344TH ST STE 303, FEDERAL WAY Contractor License No: AIREPI *032RU DESCRIPTION OF WORK: INSTALL ONE (1) 1 1/2 TON PACKAGE HEAT PUMP & CONNECT TO ONE SUPPLY AIR AND ONE RETURN AIR GRILLE. THERE WILL BE MINOR DEMOLITION WORK. Value of Construction: Type of Fire Protection: Permit Center Authorized Signature: Signature: doc: Mech City of 1ik1a Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 $6,500.00 N/A MECHANICAL PERMIT Phone: Phone: 253 942 -7028 Expiration Date: 03/18/2004 Fees Collected: Uniform Mechnical Code Edition: Date: w 7 MO2 -154 $59.81 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing s work will be complied with, whether specified herein or not. The granting of this per �d• -s not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructi +r t • performance of work. I am authorized to sign and obtain this mechanical permit. Date: cg G " v Z� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 08 -06 -2002 City of Tukwila Parcel No.: 1023049066 Permit Number: MO2 -154 Address: 11911 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 07/25/2002 Tenant: KING COUNTY METRO Issue Date: 08/06/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 10: Manufacturers installation instructions required on site for the building inspectors review. 11: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will b- co pli d with, whether specified herein or not. The granting of this per regulating construction Signature: Print Name: doc: Conditions f Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS it • • - . it presume to give authority to violate or cancel the provision of any other work or local laws • r, e • - rformance of work. Date: ` 6 MO2 -154 Printed: 08 -06 -2002 Project Name/Tenant: K itif jOUN1'1 �k11Z(/ 1 iii) f hl lll) )zLI ON" 1/4:— Value of Mechanical Equipment: f7 b600 =; (oj L '606 Site Address : City State/Zi : ygll L . a1 wfiti 96. 1 up 1.0,4 67670 Tax Parcel Number: 1 n goi Property Owner: {lip• hat/le (nuKi i. Mel lir Phone: (2t 1 ) I - 1'j,0 Street Address: pzt z h i4 t, . 5t-►) ra, City State/Zip: )4/44 - c((�I0`t -1 , Fax #: (Y' )'" ) I'V) C Contractor: Ai gie flab Ztvii. Phone: (Z�j3) c1 ci2� �7 � Fax #: ( ) 66g- rte' Phone: ( Zf ) (l4L' 1Q'i- Street Address: tWI I' / 0/41N r )t 4 5 0.1 1 % 4 t ,b, City State/Zip: TW414H Will( Fax #: (Zi'7) ,,e I ale) Contact Person: IPA erx =2- `f Phone: (7� ) re`lam 7020 _5Gon Street Address: 11 ` 6 � 1+7 {1 � 41 5(.1 i : 4 City State/Zip: 7' For - vfrif Fax #: ( -Z f3) 5 61 - i bbij ''BUILDINC".0 tAUTHOR /ZED'AGENTi., F.! t'' .:... ; ..., .... . Signature: Date: 1 ...yhi _UY Print name: G / i ZmQg � Phone: (Z�j3) c1 ci2� �7 � Fax #: ( ) 66g- rte' Address: WV , 0114 -34� ryi 91“6( -. 56 r it✓ 44 3 7 ) City/State/Zip: f ir 2+t t wim , wi9 - g l Y *fi CITY OF 'JKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: I Y) O ? — 15V )R SI Ai I USE ONI Y Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. - 6.1ANIGA4PERMIT REVIEWAi.1D APPROVAlJREQUESTED':•(TO REFILLED : :OUTBYAPPL /.CANT) Description of work to be done (please be specific): tv� 01,k. °ve f►) y " 1v i1L X D 14'11- Pity 4 t) °Aft 20 gut, 6rut6:: mltve- 196/ ip»V 01 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". fk tlli P > 0,2- RU 6iP: tow om - Uut Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11/2/99 mech pemdl.doc Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 0 7layl0- Date application expires: vi /5/o3 Application taken by: (initials) Z CL U0 N0 Lu J I- U) u_ w° Q _ ° Z = W 0 U O - 0E- W "O W Z U = 0 Z f r : Ash aim f_. ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single. Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I I Narrative of work to be done, including modification to duct work. 11/2/99 miscprt.doc Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. doc: Receipt *' City of Tukwila Parcel No.: 1023049066 Permit Number: MO2 -154 Address: 11911 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 07/25/2002 Applicant: KING COUNTY METRO Issue Date: Receipt No.: R020001131 Payment Amount: 59.81 Initials: SKS Payment Date: 08/06/2002 12:42 PM User ID: 1165 Balance: $0.00 Payee: AIRE PRO INC TRANSACTION LIST: ACCOUNT ITEM LIST: 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Current Pmts Amount Payment Check 08320 59.81 MECHANICAL - NONRES PLAN CHECK - NONRES Type RECEIPT Method Description Description Account Code 000/322.100 47.85 000/345.830 11.96 Total: 59.81 1 710 TOTAL yL Printed: 08 -06 -2002 COMMENTS: C ovvecLctvs Cnvip(e 4-e. l'i ()k 4, T'V& L.) Date Call ■ p____ 03 Special Instructions: l'. ill-L L 1-75 /,',v . Date Wa ,�a.m. Requester: SGo 7 P D _ er, Pr a t:. Type o pec io trio A l i e�,s // „ I _ r Date Call ■ p____ 03 Special Instructions: l'. ill-L L 1-75 /,',v . Date Wa ,�a.m. Requester: SGo 7 P D _ er, Ailrv4t'.!CN�hi.E �.. ^: ?�• ^, :.Y :` i'.1•.i�! ? -�LS�� INSPECTION RECORD Retain a copy with permit M O' _ INSPECTION NO " ' t PER T.NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 )431 -3670 Approved per applicable codes. 0 Corrections required prior to approval.; $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Proje c:�,�a Type of Inspe on: Addr ss: /..9!/ ( "41. �� S Date Calle• P - ,2� 03 Special I - 44- id / 6 J � . Date Wanted: a.m. 7 2 2- O'.3 m. Request Phone No: 2 3 X7 -..9Y2.5 • If '�. r' Sri.• unE} N. ti: Si:3J:iiALU.i',.W:,;Ci:�F•..' .. INSPECTION RECORD Retain a copy with permit INSPEC ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 /370Z-lsy (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMM /NTS: $47.00 REINSPECT! FE E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: 2- Type of Ins_ctioni • /� /� ; (:(77- : ( 7 Address: //9// cam'. 7 f4. I-) EI' v'c(I 0(pero■1al - Y' 60- --Vri U v\ ‘ 4- ,)0(1- Of CT H 04 Date Wanted: ( y am. -r . �� p.m. Requester; :—, C ,�T I6e :16- 7 Calf-' P4:?-- SP u P r\ 4use YS . v ' W\4 - { ' , rar'C C t \ ("If cr` re In S`0-.t r tL t A ) \'cam . U 'Acb - -KOd't` Airip \ v\c p ec-- irr— Project: (--, .� 0 64-7' 2- Type of Ins_ctioni • /� /� ; (:(77- : ( 7 Address: //9// cam'. 7 f4. , ai s , Date Called: - z v/ 4 3 _ Special Instructions: ! @e6- L „/ - / !/�'F- GiGG��1 Date Wanted: ( y am. -r . �� p.m. Requester; :—, C ,�T I6e :16- 7 Calf-' P4:?-- Phone No: S ' 7 C ? - �*Y /cf .C-- INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. Inspector: c Date: 3 c). L o 3 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 1v} y_,,,,,,,,., rt;, F,;: i!:..... r" •r3- oM }4f;;b1 s',b;a:ii �7i`.;i.: INSPECTION RECORD Retain a copy with permit ?i,'.k F4[ "' • ' 9Z t toil eAv r brs a Pa s 2 ,�.•s n z: (206)431 -3670 Corrections required prior to approval. Date: ct: T c r� — Fr n Ty Inspec uc io �n: — III #74 ��,/141 wYS Date Called. 77277 n 3 c. Special Instructions: J Date Wanted. I i j r , ‘ ,. ) Requester: 4 Sk) el1 -U/ i Phon ... v;f: Lyl.q �iJl::ui J Jtd:.;:ro�.;t.y- >ti!;:Ci: i::•i•iit.n.i4i4�i'_i��t� INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit S- 735 Corrections required prior to approval. 996 COMMENTS: bb Sct s,n ; , R A ( -r e) 37./(177" F r cN ►' f A-0 e ss 1> V?) e. ,°t•t 1 CJ hAr- i i r`_ 6 l i O I'J c?€ T S srvl :C? ST (Z Pr c r: Date: 47.00 REINSPECTIO FEE REQUIRED. Pri ' r to inspection, fee must be aid at b300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: I Date: 7A4i )3 ei%,:: �Li..::75.�.�i'.v`. J• King County Dept. of Development and Environmental Services Building Services Divhlon 900 Oakesdalc Avenue Southwest Renton, Washington 98055 - 1219 (206) 296 -6600 TTY (206) 296 -7217 Parcel Number: 10 2.- Ce-4 • 4 i0l0 ( p Legal Description: SEE GENERAL CONTRACTOR BEISLEY (if not yet assigned, check box at right) Related Permits or PreApp number: Address of proposed work: s •: dt. I A • ar! , Descriptive summary of proposed work: SP,P, COVER SHRFT Valuation of project: $6 00 FOR MECHANICAL Check i applicable Items This is: This is: Mailing Address: Applicant Name: Mailing Address: Contact/Agent Na Mailing Address: Applicant Signature 0 New Construction 0 Sign ❑ Single Family 0 Retail/Office Property Owner: KING COUNTY METRO ti Affidavit for Applicatton.doc b-aff- app.pdf RAEDER 01/28102 .. r...wm.vC.., =w•.WJ.nfewi.,IPORNO M.+P0A1Iw.«.,:. m, 0,.. Affidavit for Application Form Alternative formats available upon request Application number assigned: INC . 0 address not assigned yet 11911 EAST MARGINAL WAY SOUTH TUKWILA, WA. 98168 Contractor's License #: AIREPI '032RU Expiration Date: 1 -18 -04 XQ9 Remodel /Addition 0 Accessory Structure O Tenant Improvement 0 Other 0 Duplex or Multi - Family 0 Commercial /Industrial 0 Agricultural 0 Other Telephone Number: 7 06 -6R -1130 821 second avenue City: SEATTT,E State: WA _ Zip: (* 1 ) $ ! # # ) 98104 =1598 AIRE PRO INC - ( SCOTT RAEDER Telephone Number: 253 942 7028 1119 SnU1TH 3 STREET City : - FEDERAL,JAIAVate: WA ` Zip: ( *) ) # me: SUITE #303 Telephone Number: 98003 SCOTT KAEDER (A1RE PRO INC. 253- 942 -7028 City: R 4Rtke tltte: WA Zip: _943003 1112 SOUTH 544t11 STKt.,ET, Sensitive Area Comoliance; The undersigned applicant declares: 1. That the applicant is competent to be a witness herein; 2. That the applicant Is the applicant for the above project; 3. That to the best of the applicant's knowledge, the sensitive areas on the development proposal site have not been illegally altered; and 4. That the applicant has not previously been found in violation of sensitive areas regulations for any property in King County, or alternatively, that if there have been any violations, such violations have been cured to the satisfaction of King County. I am submitting for a permit authorized by the uniform building, fire or mechanical codes and in anticipation of having it approved or approved with conditions I have read the following statement and understand that failure to comply with all conditions once construction is begun may necessitate an Immediate work stoppage until such time as compliance with the stipulated conditions Is attained. I certify that I have made a diligent inquiry regarding the need for concurrent state or federal permits to engage in the work requested under this building permit, and no such permits are required or I will have obtained the required permits prior to Issuance of this permit. I understand that the granting of this permit shall not be construed as satisfying the requirements of other applicable Federal, State or Local laws or regulations. In addition I understand and agree that this permit does not authorize the violation of regulations. In addition, I understand and agree that this building permit does not authorize the violation of the Endangered Species Act as set forth at 16 U.S.C. § 1531- 1543, including the prohibition on the "take" of threatened or endangered species. "Take" is defined at 16 U.S.C. § 1532(19). I fully understand that it Is my sole responsibility to determine whether such "take" restrictions would be violated by work done pursuant to this permit, and I understand that I am precluded by Federal Law from undertaking work authorized by this permit if that work would violate the "take" restrictions set forth at 16 U.S.C. §1538, 50 C.F.R. §17.21, 50 C.F.R. §17.31,50 C.F.R. §223 and 50 C.F.R. §224. I certify under penalty of perjury and under the laws of the State of Washington the foregoing is true and correct. I further certify that all easements, deed r tri • • s, or other encumbrances restricting the use of the property are shown on the site plans submitted with this a accept financial responsibility for all fees associated with this permit or approval and will receive any r �� • •': se mall any refunds to the address above. Date 7 25 02 Page 1 of 1 �.w,gy.mw e. c• w.-..., r....,: r...•--,•• r.» �r'•+ w..+. nwnnar•. M+ eY.++%» 7oenaFRM' lutrlmMi�'.. kC+ rYyr' jj tH�X !'Pi'iV+'AEA3l.+!Qt'.»»;.•.sv� King County Department of Development and Environmental Services Land Use Services Division 900 Oakesdale Avenue Southwest Renton, Washington 98055 -1219 (206) 296-6600 TTY (206) 296-7217 FOR CORPORATIONS/BUSINESS ASSOCIATIONS: Signature of • plicant SCOTT RAEDER Certification & Transfer of Applicant Status Alternative formats available upon request FOR CURRENT OWNER: I, 411611111+iMIN (r , (print name) hereby certify that I am an /the owner of the property which is the subject of this application for permit or approval. If I am not the sole owner of the property, I certify that I am authorized by any and all other owners of the property to make this certification and transfer any an all rights I /we have to apply for this permit or approval to the person listed below. I, therefore certify that (print name) is the "applicant" for this permit or approval and shall remain the "applicant" for the duration of this permit or approval unless "applicant" status is transferred in writing on a form provided by this department. By being the "applicant," that individual assumes financial responsibility for all fees and will receive any refunds paid. I certify under penalty of perjury under the laws of the State of Washington that the foregoing is true and correct. Signature of Owner Date Signed FOR INDIVIDUALS: I, , (print name) hereby certify that I am the "applicant" for this permit or approval. I shall remain the "applicant" for the duration of this permit or approval unless "applicant" status is transferred in writing on a form provided by this department. I accept financial responsibility for all fees associated with this permit or approval and will receive any refunds. My mailing address is: I certify under penalty of perjury under the laws of the State of Washington that the foregoing is true and correct. Signature of Applicant Date Signed OR I, SCOTT RARDRR , hereby certify that I am an authorized agent of AIRE PRO INC_ , a corporation of other business association authorized in the State of Washington and that this business association is the "applicant" for this permit or approval and is financially responsible for all fees and will receive any refunds paid. This association shall remain the "applicant" for the duration of this permit or approval unless "applicant" status is transferred in writing on a form provided by this department. The mailing address of this business association is: 1112 SOUTH 344th SfitREET, SUITE #303 FFDFRAr. WAY, WA. 98003 I certify under of of perjury under the laws of the State of Washington that the foregoing is true and correct. 7 -25 -02 Date Signed Certification & Transfer of Applicant Status lc- cer- trapstat 1/15/02 Page 1 of 2 unO la NOTICE TO APPLICANTS: By law, this department returns all engineering and other plans to the applicant. If, however, you wish to authorize the department to return engineering and other plans directly to the engineer, architect, or other consultant for the limited purpose of making corrections, please designate below: O I authorize this department to return plans directly to my consultant(s) for the limited purpose of making corrections, as designated on this form. CONSULTANTS: Certification & Transfer of Applicant Status lc -cer- trapstat 1/15/02 Page 2 of 2 COVER SHEET FOR MECHANICAL PERMIT FOR KING COUNTY METRO SOUTH FACILITIES OFFICE/ WORKROOM REMODEL 1. NAME, ADDRESS, TELEPHONE NUMBER OF OWNER KING COUNTY METRO; 821 2 AVE, SEATTLE, WA. 98104 -1598; 206- 684 -1330 2. AGENTS NAME, ADDRESS, TELEPHONE NUMBER AIRE PRO INC.; 1112 SOUTH 344 SUITE #303; FEDERAL WAY, WA. 98003; 253- 942 -7028 3. STATEMENT OF THE SCOPE OF WORK THAT PERMIT WILL COVER INSTALL ONE AND ONE HALF TON PACKAGE HEAT PUMP AND CONNECT TO ONE SUPPLY AIR AND ONE RETURN AIR GRILLE. THERE WILL BE MINOR DEMOLATION WORK. 4. SYSTEM FOR A BUILDING OR TENANT SPACE FOR A TENANT SPACE 5. NUMBER OF RELATED APPLICATIONS GENERAL CONTRACTOR BUILDING PERMIT AND ELECTRICAL PERMIT PLUS MECHANICAL PERMIT 6. LEGAL DESCRIPTION OF PROPERTY THAT PORTION OF THE NORTHEAST QUARTER OF SECTION 9, T23N, R 4E, WM AND THE NORTHWEST QUARTER AND OF THE SOUTHWEST QUARTER OF SECTION 10, T23N, R 4E WM, KING COUNTY WASHINGTON MORE PARTICULARLY AS DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHEAST CORNER OF SAID NORTHEAST QUARTER OF SECTION 9; THENCE N89* 14' 10" W, 224.42 FEET ALONG THE SOUTH LINE SAID NORTHEAST QUARTER TO THE EASTERLY MARGIN OF PRIMARY STATE HIGHWAY NO 1 (AKA SR 99) 6. SITE PLAN SEE SHEET 1 OF 16 IN PACKET 7. CONTRACTORS REGISTRATION NUMBER AIREPI*032RU 8. AFFIDAVIT FOR APPLICATION SEE ATTACHED IN PACKET 9. CERTIFICATION AND TRANSFER OF APPLICANT STATUS FORM SEE ATTACHED IN PACKET August 13, 2003 Scott Raeder 1112 S 344th, Ste 303 Federal Way, WA 98003 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Application No. MO2 -154 11911 East Marginal Way South Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection: or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to September 22, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, e- Stefanla Spencer Permit Technician 7 Xc: Permit File No. MO2 -154 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 March 11, 2003 Scott Raeder 1112 South 344th, Ste 303 Federal Way, WA 98024 City of Tukwila RE: Permit Application No. MO2 -154 11911 East Marginal Way South Dear Permit Holder: Based on the above, you are hereby advised to: Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director lU 00 � W W J rn LL WD 2 g co 3 O � U �. 0 -, • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final 0 ;— inspection. = w LLO .. z U= O~ Z In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension no to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to April 2, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania`Spencer Permit Technician Xc: Permit File No. MO2 -154 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite 11100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: MO2 -154 DATE: 07 -26 -02 PROJECT NAME: KING COUNTY METRO SOUTH FACILITIES SITE ADDRESS: 11911 EAST MARGINAL WAY SOUTH X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS ..oti Buil 1 ttivision [�] Public Works ❑ Documents/routing slip.doc 2.28.02 " PERMIT COORD COPY i '' 44* '` PLAN REVIEW /ROUTING SLIP REVIEWER'S INITIALS: sit- 40' Fire Prevention Planning Division ❑ Structural ❑ Permit Coordinator Incomplete DUE DATE: 7 -30 -02 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [1( Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS RO9TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 08-27-02 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: BI¢seRIrfI D P e Y Staff Initials: z re w UO N o (ow w 0 Z � H O Z 1— W W U N OH W W Hr- LL w z U O z LICENSE DETAIL INFORMATION Form Page 1 of 1 * * * * * * * * STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License AIREPI *032RU Name AIRE PRO INC Address 1112 S 344TH ST STE 303 Address City FEDERAL WAY State WA Zip 98003 Phone Number 2539427028 Effective Date 12/31/1997 Expiration Date C3/18/2004 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code AIR HEAT,VENTILATION,EVAPORAT Other Specialties OTHER (SPECIFY) UBI Number 601771753 * * *VIEW CROSS REFERENCE FILE FOR THIS LICENSE* * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * VIEW CONTRACTOR INSURANCE INFORMATION * * * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page https: / /wws2 .wa.gov /lni /bbip /TF2Form.asp ?License= AIREPI *032RU 08/06/2002 H No. ABBREVIATIONS: a to AMA. A^.1 k: . n'.:1 k1 BC. BLDG E. BLK 3M. BR. ?RG. M. C.S CA3 CF C.E.M. ?LAS. C L .J. C.i. C.J. CIG CLP. C.M.U. C.O. COL CONC. CONS'. CONT. CC.RR. Cr . C.P. D D. DBL. DET. DEMO. O.F DIM DiSP ON. DR. D.S. Dw. DWG. t E. EA. E. I.F.S. E.J. ELEC E.P. EQ. EXIST. EXT. E. PT. E.S. :..CLP. F FA F.D. FDN. FX- F.H.C. FIN. FLASH. FLR. FLUOR. F.D.S F.O.W. FT . PG. FURR. G I.D. INSUL. INT. !.P.S J JAN. JST. JT. GA. GALV. C.B. G.I. GL. GWB. GWB. /WR. H. H.B. H.C. HOWE. H'T HORi2. HP HCR And Angis Ces+ter Lire Diameter o• Round Anchor 6oitt kote t ca' Acast;cot Ceding Panel. Aco. : c iue ken .,'c,r AC;;Stco�e Above Finish Floor Mr r.urn Approximate Architect (u: J;) &plain; Block ocicing aeon. Bria 9eerinc Eietweer L ut -tn Roof 3abr Charging Station Cabinet Carpet _ Cctct- oosin / ;Thalkboard Cement. Plaster Corner vuo'd C.:st Iron Controi Joint Ce�lirg Ciear Concrete Masonry Unit Cleanout Column Concrete Construction Continuous Corridor Ceramic-Tile Center Point Dryer Double Detoil Demolition DrinKing Fountain Dimension Dispenser Deod Load Down Door Down Spout Dishwasher Drawing East Each Exterior Insulation_ Finish System ... Expansion Joint Elevation Electrical Eierrical Panel Eaua Existing Exterior Epoxy Paint Exposed Structure Exterior Cement Placer Fire Alarm Floor Drain Foundation Fire Extinguisher Cabinet Fire Hose Cabinet Finish (ed) Flashing Flooring Fluorescent Face cf Stud Face of Wall Foot or Feet Footing(s) Furring Gage Galvanized Grob Bar Galvanized Iron Glass Gypsum Wallboard Gypsum Wall000rd Water Resistant height Hose Bibb Hollow Core Hardware Height(s) Hollow Metal Horizontal. Hour Header Inside Diameter Insulation Interior Iron Pipe Size Janitor Joist Joint T U V REVISION S 0 P 0 R I. N VAR. V.C.T. VERT. JEST V W.C VER. w W IV/ W.B. W.C WD. W.G. W.H. W/O W.P. W.R WI W.W.F L. 'JIY. MAIL M.6. M AOP. k.r.. MA. MSC. M .J. Ir ul� N N.L.C. N T.S OA C.C. v .J. C.F.C.I. 0 T OPP. PL. P. LAM. PEAS. PLWD. PR. PT. PART. r T.D. D.T. R. RA R.o. L. J. RAF. REFER. REINF. REC. RESIL. RM. R.C. R.T.M. RS.T.. R.C.P. S. S.C. SCHED. S.D. SECT. Si'T SAM. S &L. S.N.D. SC. S.S. 5.5?1.. STD. STOR. STRUC. SUSP. S.V. SJ. /CR. SAC T. T.B. TD. /WR. TEMP. T &G THK. T.O.P. T.T.D. T.V T O.W TYP. T.O.B. T.O.C. T.O.S. T.S TFRR. T.S.C.D. UNPIN. U.N. 0. Length t.^tiaror Ire :rood Maximum Macrae We Mecarr. Density Covered Plywood Mecnance Wr.focturer Manhole Ma rh.r^ Miscellaneous Masonry Doering Mounted etc Microwave Nortn Not In Contract Not To Scale O eraE Ooszune On Center O..rtsiae Diameter Owner Furnished Contractor Instated Office Opposite Portland Cement Plaster Plate Plastic Laminated Piaster PtYwooct Pc ;r Paint Partition Paper Towel Dispenser Quarry The Riser, or Rodais Return Xi- Rubber Base, or Resilient Base Roof Drain Reference Refrigerator Reinforces Required Resilient Room Rough Opening Rubber Tire Mat Resilient Stair Tread Reflected Ceiling Plan South Solid Core Schedule(d) Soap Dispenser Section Sheet Similar Stein & Lacquer Sanitary Nopein Disposal Square Service Sink Stainless Steel Standard Steel Storage Structural Suspended Sheet Vinyt Sheet Vinyl Chemical Resistant Symmetrical Tread Tack Board Towel Dispenser Waste Receptacle Telephone Tempered Tongue & Groove Thick Top of Pavement Toilet Tissue Dispenser Televisor Top o' Wall Typicai Top of Beam Top of Curb or Concrete Top of Structure Tube Steel (Pipe) Terrazzo Toilet Seat Cover Dispenser Unfinished Unless Noted Otherwise Varies Vinyl Composition Tile Vertical Vestibule Vinyl Wall Covering Verity Washer, West, or Width With White Board Water Closet Wood Wire Glass Water Heater Without Water Proof Waste Receptacle Weight Welded Wire Fabric BY AP P' D DATE SYMBOLS KEY: Location on Sheet Sheet Number Location on Sheet Sheet Number Location on Sheet Sheet Number Location cn Sheet Sheet Number Ra SH1 A2.4 10'-0' Et,EVA710N /DATUM TARGET T.O.C. 8ULDWe; GM U1E DOOR TARGET 1114DOW TARGET (peon and elevation) REL.ITE TARGET LOUVEF TARGET INTERIOR ELEVATION ;Orrow indicate` view drret:ti0n ROOM NAME ROOM NUMBER REVISION CLOUD DETAIL REFERENCE WALL SECTION BUILDING SECTION VICINITY MAP: (target at each end of tine' EXTERIOR ELEVATION WALL. TYPE GRADE ELEVATION KEYNOTE MATCHLINE Nfe itt +Partin' 1000 Lenora St. Suite 223 Seattle, WA 98121 (206) 622 -9450 (206) 622 -9462 fax Architecture Urban Design Planning Interior Design MATERIALS KEY: Not to Scale PROJECT DIRECTORY: OWNER: KWG COUNTY DEPARTMEN7 OF TRANSPORTATION 20: SOUTH 41C1CSON ST.. M.S. KSC 0417 reAITLE. ikk 9 t1D4 -3166 BUILDING CODE SUMMARY: Protect Location: Focdities Maintenance South 119'1 E Marginal Woy S. Tukwila. WA 98168 Leg Description: That portion of the Northeast quarter of section 9, T. 23N., R. 4E.. W.M.. and the Northwest quarter and of the Southwest quarter of section 10, T. 23N.. R. 4E, W.M.. King County. Washington, more particularly as described as follows: Beginning at the Cniihxxt comet, at said Northeast quarter of section 9; Thence N891 4 224.42 feet along the south line sold Northeast quarter to the easterly margin of primary state highway no. 1 (ako SR 99); Fxnstlnq Btnlduta: Miscellaneous support offices and bus maintenance facility. Existing Construction Type: V-N (Sprinkled) Seismic Zone: 3 Existing Occupancy Imes and Areas: 6-2 - Offices clod awWities H - Maintenance shops 17.403 st. 18,161 s.f. 35,564 s.f. total Ilex_ cons as shown ei thi nie„: Remodel of existing space in 8 -2 area: ±1,249 s.f. Area r: new oddition to existing buiT ;irg: f? st t Codes: Original budding constructed under 1982 Uniform l8r,ilding Code New work as shown in this project designed under 1997 Uniform Budding OCCUPANCY LOAD CALCULATIONS: Existing egress condition remains unuttered. The remodel of the existing offices does not add to the occupant load of the building. PROJECT SUMMARY: Work includes remodel of existing meeting room into workroom; construction of interior walls to create two additional offices in existing general office area; demobtion and relocation of existing wall between two existing offices; odd:T7on of new rooftop IficAC tM to service remodeled workroom; modify existing sprinkler system to provide coverage for remodeled offices. KING COUNTY METRO SOUTH FACILITIES OFFICE/WORKROOM REMODEL 11911 E. MARGINAL WAY S. TUKWILA, WA 98168 Code DESIGNED: SG DRAWN: SG CHECKED: SC RECOMMENDED: PROJE MANAGER: APPROVED: IBIS NO: WORK REQUEST: CONTRACT NO: C Thence along said easterly margin Northwesterly 437.32 feet long the arc of a non - tangent curve to the left, having a radius of 1265.90 feel the radius prwnt of titian bears 588'13'22Ni, through a central angle of 19'4737' to the southerly margin of primary state highwc; no. 1 (aka SR 99) and a point of curvature: Thence along said southerly margin easterly .113.'9 feet along the arc of c non - tangent curve to the krt. having a radius of 1502.40 feet, the radius point of which bears N12'21'45E, through a central angle of I1'56'37; Thence continuing along a said southerly margin NO0'25'08 E, 10.00 feet to a point of curvature; SCALE: AS SHOWN ONE INCH AT FULL SIZE 1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Departizzent of Transportation INDEX OF DRAWINGS: . 911EET No. DRAWING He. DRAWING TTflE ARCHITECTURAL 1 A1.0 T Ale 3 43.0 4 A4.0 5 A5.0 6 n'6.,: 7 A7.0 8 A8.0. 9 STRUCTURAL 10 S1.0 STRUCRIRAL NOTEES AND PLANS MECHANICAL 11 11/1 .0 12 M2.O 13 At3.0 ELECTRICAL 14 E1.0 15 E2.0 16 E3.? TOLE SHEET SITE PLAN DOIOUT N PLAN FLOOR DI AN ROOF RAN letICTED aElUftT PLAN SECTION. EXTERIOR ELEVATION, tNTER)OR ELEVATIONS '_ DCR 7r ScniEDt: DUALS ( FFlNLSH PLAN T ES D & C�RS ME:l* lCAL DETAILS, SCHEDULES do Sr P-11 S MECtiWliCk✓ . DEEMCLIT1ON & MECIWiiCAL PLAN PLUMBING PLAN ELECTRICAL SYMMBLS & A53RE',NATIOtS LIGHTING DEMOLITION UGNTNG PLAN POWER DELiOUTiON PLAN AND POWEt2 /COLIM PLAN Thence c ontrir.:w,y along said southerly margin easterly 225.19 feet along the arc of a non - tangent curve to the left. having a raaus of 1492.40 feet, the adios point of which oeurs NOO'25'08 E, through a control angle of 08'38'+4' to a point of tangency; Thence =wig an s91C scatheiN margin' N81'46'241, 393.60 feet; Thence ccntinuing along said southerly margin S86'45'29 365.88 feet to the westerly margin of East Marginal WQy; Thence along said westerly margin 516'29 534.84 feet; G: ra l j RA E F E r i ..Lt � u:. r�r� lt� Ulf, ru FOR. [� .FCTRlCAL [V .As Pli tNG CITY OF TUi: JV LA Ft' IILE)iNG E)lV!3,CN METRO TRANSIT DIVISION SOUTH BASE FACILITIES OFFICE 1 WORKROOM REMODEL TITLE SHEET Thence S78'4.' 27'*, 415.05 feet; Thence N8 - 30'37'W. 726.40 feet to the west fine of said Southwest quarter of section 10; Thence N01'48'37 107.22 feet along said west fine to the point of beginning: Containing 16.00 acres, more or less. Note: 1) The site contains 18.3 acres, more or less, including easements. F!'F= Cr understand ',n3; the an C pr subject to errors �,,k a,.,, owls a�� rrors and omiss.ons . : :.,c approval of pans does not 3u}' • -: adopted Code cr of any ? ;FtCel eceipt co actor's Cony «:. . • ; rs ackraMedc;ed. By_ Date Perrmt No MO2- 6=4 2) all quantities listed are for permit application purposes only and not to be used for bidding purposes- -------- C ITN i',4 ` t� L. 3 ti 9'1' DATE. QT -1S =2002 DRAWING NO; A1.0 SHEET NO: OF 1 16 RECEIVED CITY OF 11..!K'1ViLA JUL 2 5 20e PE .i :T CENTQP o -10 i No . ROOF PLAN NOTES 1. EXISTING FEATURES ON ROOF PLAN SHOMtimi FOR INFORMATIONAL PURPOSES ONLY. CONTRACTOR TO FIELD VERIFY ACTUAL CONDITIONS PRIOR TO CONSTRUCTION. ION. 2. CONTRACTOR TO REPAIR DAMAGES TO EXISTING ROOF AND ROOF FEATURES, INCLUDING BUT NOT UMffED TO EXISTING ROOF SURFACE, HVAC EQUIPMENT, FUASHING, ETC. CAUSED DUE TO WORK DURING THIS PROJECT. 3. ANY PENETRATIONS OF THE DOSING ROOF SYSTEM, ROOFING PATCHES, FLASHING AT ROOF PENETRATIONS AND OTHER ROOF REPAIRS SHALL BE BY WORKERS EXPERIENCED WITH THE DUSTING TYPE OF ROOF (EPDM) EMPLOYED BY AN AUTHORIZED FIRESTONE ROOFING APPLICATOR. SEE ALSO SPE RCATION SECTION 07520. 4. REFER TO MECHANICAL DRAWING FOR CURB DETAIL FOR NEW HVAC EQUIPMENT. REVISION BY APP'D DATE ) Plierritt+Pardii 1000 Lenoro St. Suite 223 Seattle, WA 98121 (206) 622 -9450 (206) 622 -9462 fax rIEXtSTING ROOF ACCESS DOOR Arcbitedure Urban Design Planning Interior Design • • 1 - -,iticsitO"AI'[SsiTS - - ' 1 - -- EXISTING lALKING PI JS ;; EXISTING ROOF DRAW, TYPICAL COSTING VENT EXISTING WALKING PADS ROOF PLAN - SCALE: 1/8' =1'-0 I , IM E11111111 --_ =11111 .= —_ 1 ES ELLIOTT PRY STALE OF eti1N670N • F : �� -- _ • •1' DUSTING EPDM RC iF WITH R YAW I` 1 r NEW WALJ friC PADS. 'RUBBER GUARD' BY FIRES OhE OR AS APPROVE^ BY 1 KING COUNTY PROJECT REPRESENTATIVE. L _ EXISTING PARAPET 4' [Y lti' DESIGNED: SG DRAWN SG CHECKED: SC RECOMMENDED: PROJECT MANAGER: G APPROVED: IBIS NO. WORK REQUEST: CONTRACT NO: immung � I SiSO C.r SCALE: 1/8".1 SITE LOCATION NO: STOP HUG UNIT_ REFER TO MECHANICAL DRAWING FOR CURB DETAIL �I--- EXISTING PARAPET ONE INCEk AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY King County Department of Transportation METRO TRANSIT DIVISION SOUTH BASE FACILITIES OFFICE rWOR ROOvM ReODE ROOF PLAN Ma 2- /5't' ! DATE J 01 - 18 - 2002 DRAWING NO- A5.0 SHEET NO. OF 5 16 RECEIVED CITY OF TUKWILA An. . 2 5 7002 PERMIT CENTER 0 5 0 C Cri w No. CODE FF:) MEN S. A deny= i and emsJe bon shag cmfam to the reee eme nts of the Urilam ace, 1997 &Len. SPEOAL CONC7TIONS: Contracts sha! en a1 levels, denensiats, and existing ccnibons in the fielc be';ae croceeong Contractor shah notify the Project Representative of are discrepancies or field changes price lc relation or fabrication. in case of discrepances between the existing conditions and the drawr^s , the Contracts shah obtar direction from the Project Representative before proceeding Deneesices note:, as plus a minus (T) indicate unverified cfroensions and are approximate Notify Prteec' Representative irrvnediatefy of conflicts a excessive variations from indicated dimensien 'voted dimensions take perecence over scaled dispersions -00 NOT SCALE DF;AYIIN ,( S . Dimensions of existing cendborts may be based on record drawings and are to be tied - verified by the Contracts. Contra to shall verity a existing conditions betae comrnena ng any demolition. Contracts shall provide adequate shoring and bracing of all structural members, existing cons uction and sot: excavations, as required, and in a manner suitable to the work sequence Temporary shoring a d Lacing shall not be removed tied aI final connections have been completed in accordance with the drawings and materials have atheved design strength No reinfacing bars in existing construction snail be cut unless directed to by the Architect a as shown on the deewings. Contractor stall re responsible for all safety precautions and the metnods, techniques, sequences or procedures required to perform the work „ a: Uniform Building Code, 1997. AP topsoil agar>ics and loose surface sod shall be removed from beneath ttti supporting concrete slabs or paving. Concrete work shall conform to all requirement of Chapter 19 of the Uniform Building Code. Conaete shenolhs that be verified by standard 28-thy cylinder tests, unless approved otherwise Concrete rakes shall conform to the following: f c Test Age (dave) LI& 3,000 28 slaty -on- -grade The Contractor shall submit concrete mix designs for approval 2 weeks prior to placing any concrete. The mix design shall be in conformance with UBC 1905. The submittal shall indicate where each concrete mix is to be used on the project, as well as the maximum aggregate size of each mo. Maximum aggregate size that conform to the specifications. ADMIXTURES: Water- redur,,ng admixtures may be incorporated in concrete mix designs, but shall conform to ASTM C 4.c.41. and be used in strict accordance with the manufacturer's recommendations. CaG2 or other water- sokible chloride admixtures shall not be used. WATER /GEMENT RAT Water /cement ratio shall be measured by weight and shall be based on the total cementit,ous material. Water /cement ratio shall be determined by the supplier based on strength requirements and shall not exceed the maximum water /cement ratio if shown above. SLUMP Field measured slump shall conform to the submitted concrete mix design. Tolerance of slump shall conform to ASTM C 94. AP CONTENT: An air - entraining agent conforming to ASTM C 260 shall be used in all concrete mixes for fiatworik which is exposea to weather. The amount of entrainec air shall be 5 percent ± 1 1/2 percent by volume. The amount of entrained air shall be measured in the field at the discharge end of the placing hose. CURING if the air temperature will exceed 75 degrees F. within 48 hours of placing concrete a most cure shall be applied to the concrete to a period or 36 hours atter finishing cre mete surfaces. Refer to the project specifications for curing requirements. REINFORCING STEEL MATERIALS Deformed Bars - ASTM A 615, Grade 60 REVISION BY APP'D STRUCTURAL NOTES DATE R iMEr tr STEEi ' Reinforcing shat be waled as specified by the txgect sPeadOtDons and Tie ClgSl Marra of Standard Practice; M3 Rentacng steel shag be detailed in accordance with 'AO 'Jana of Standard Practice for Detailing Reinforced Gonaete Structures,' AU 315. Lao a1 rei:nfacirg bars as noted on the c swings. We spice length is not shown use Type Lb (Lbt for top bars) spbee. Reinforcing steel shah have protection as fellows, unless noted otherwise Stab Bar .. . STEEL REFERENCE SPECIFICATIONS Welding - AWS DU AWS prequalitied pint details Weider Cerbficatbn Washington Association of Budding Officials (WABO) Steel Decking -- Steel Deck institute, AZSi- Specifications for the Design of Cold -Famed Steel Structural Members METAL DECK Any required repairs to steel deck shad cmfam to ASTM A 653, Grade 33 minimum. Minimum ty = 33,000 psi for Type N roof deck and 38,000 psi to all other decks. IDedk welding shall be in ac adance with AWS D13, 'Specification fa Welding Sheet Steel in Structures.' Welders shall be quailed by WABO Light Gauge Certification. Contractor shall provide closure plates, hashing and all miscellaneous light gage metal shapes necessary to complete any required metal deck repairs. The rririrnum bearing required shad be 2 inches. P2rtilli 1y 1000 Lenora St Suite 223 Seattle, WA 98721 (206) 622 -9450 (206) 622 -9462 fax Architecture Mon Design Panning Interior Design .Catu r I i iJro /o2 I:xJ 9U !n, II) i DESIGNED: MB DRAWN: RF CHECKED: NF RECOMMENDED: PROJECT MANAGER . GAS APPROVED' tBIS NO: WORK RtQUEST • CONTRACT NO: Cin i Se) c. ONE INCH AT FUt1 SIZE I 1• f IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: SCALE: AS NOTED I/ i • !r ZZ � PARTIAL ROOF FRAMING PLAN SCALE: 1;18 =n' -O• King County Department of Transportation Kr t - HVAC UNIT SEE MECHANICAL FOR CURB; f ( PROVIDE PENETRATiON IN I EXISTiNG METAL ROOF' DECK AS REQUIRED; PROVIDE REINFORCING AND TRIM AS REQUIRED; SEE METAL QECK NOTES ( .-2-. ` r1 ) f 1 4' CONCRETE SLAB SEE CJNCRETE NOTES ( 114 ® 6'OC D PARTIAL STRUCTURAL FOUNDATION PLAN SCALE: 1 /3"=1' -0r EXISTING SIDEWALK DRII L & EPDXY GROUT p : DOWELS @ 6” W /4' EMBED, LAP BARS 4 8 16 n 4 —`D METRO TRANSIT DIVISION SOUTH BASE FACILITIES OFFICE/WORKROOM REMODEL STRUCTURAL NOTES 1 DATE' 1.18.02 DRAWING NO: 51.0 SHEET NO. OF 10 16 RECEIVED CITY OF TUKWILA JUL 2 5 2002 PERMIT CENTF No. ECONOMIZER HOOD WITH REUEF DAMPER. ADJUST TO DELIVER 100 CFM OUTSIDE MR OR 100 X OUTSIDE AIR IN ECONOMIZER CYCLE. 36 X 25 HOLE THRU ROOF 1' 1/4' X 21 TO 12'• DUCT TRANSITION SUPPLY AIR VOLUME DAMPER ADJUST TO DELIVER 600 CFM REVISION r 1 4"0 NECK X 24" FACE CEJUNG DIFFUSER BY SHEET METAL FLASHING • — � RECEIVER PAC -1 BASE SEALING MATERIAL WOOD NAILER UNIT MOUNTING CURB REMOVABLE SHEET ]METAL COUNTERFLASHING FLASHING MEMBRANE (ADHERED TO CURB) STRUCTURAL SUPPORT AS REQUIRED SEE STRUCTURAL DRAWINGS FLEX CONNECTION (TYP) 18 1/8" X 11 1/2" TO 12"0 DUC' TRANSITION APP'D DATE HIGH — DOMED. CAPPED. GASKETED FASTENERS (APPROX. 18' [4.57 mm) O.C.. DEPENDING UPON WIND ZONE AND LOCAL CONDITIONS; MINIMUM TWO FASTENERS PER SIDE) SEISMIC BOLT THRU HEAT PUMP BASE AND CURB RETURN MR VOLUME DAMPER 12"11 INSULATED FLDOBLE DUCT (TYP) SEALANT (IF REQUIRED BY THE SPECIFIC SYSTEM) EPOM ROOF MEMBRANE 4" RIGID BOARD THERMAL INSULATION METAL ROOF DECK PREFAB CURB NOTES; 1. THE CURBS, TOP WOOD NAILER, AND SEAL STRIP ARE TO dE SUPPLIED BY THE CURB MANUFACTURER. 2. ATTACH NAILER TO DECK WITH SUITABLE FASTENERS. 3. WHEN POSSIBLE, THE MECHANICAL. UNITS SHOULD NOT BE SET UNTIL THE ROOF MEMBRANE AND FLASHING HAVE BEEN INSTALLED. PACKAGED ROOFTOP HEAT PUMP DETAIL SCALE:1 /2" 17928 BOTHELL EVERETT HWY SE, SUITE H BOTHELL, WASHINGTON 98012 ENGINEERS, LLC (425) 481-7735 FAX (425) 481-7692 CONTACT: OWEN NITTA JOB NUMBER: 013067 HVAC SCHEDULE PACKAGED ROOFTOP HEAT PUMP: TRANE MODEL WCD- 018— F— I —L —O, 18.400 BTUH TOTAL. 12.000 BTUH SENSIBLE COOUNG CAPACITY 0 85'F OUTDOOR DRY BULB. 67F OUTDOOR WET BULB. PROVIDE FARR 30/30M 2" THICK THROWAWAY FILTERS. EER =9.35. 9,500 BTUH HEATING CAPACITY WITH 17F OUTDOOR TEMPERATURE. COP =3.00. PROVIDE BAYHTRN105A, 3.74 KW SUPPLEMENTARY HEATER. ECONOMIZER KIT AND BAYCURB030M ROOF MOUNTING CURB. PROVIDE SINGLE POINT POWER CONNECTION. 44 MINIMUM CIRCUIT AMPS, 45 MAXIMUM OVERCURRENT PROTECTION DEVICE. 208-230V/193 /60HZ. QEILINP DIFFUSFR; TTTUS "OMNr NT MODEL. ALL F EEL CONSTRUCTION WITH FACE PANEL, LAY —IN FRAME WE 3 WITH Pk.ISMIC CUPS. #26 WHITE ANODIC ACRYLIC PAINT FINISH. m1E4 GRtL ; TITUS MODEL 50R, EGGCRI.IE CORE WITH STEEL FRAME AND BORDER TYPE 3 FOR LAY —IN CEIUNG, WITH SEISMIC CUPS. #26 WHITE ANODIC ACRYLIC PAINT FINISH. C ti EXPIRES: 7/8/02 J DESIGNED: DRAWN: CHECKED: RECOMMENDED: AP IBIS NO: woRK 11EGUESI: CONTRACT NO: G/515oG PLUMBING SCHEDULE ONE INCH AT FULL SIZE I....._ 1" IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: ABBREVIATIONS A AFF AMP BHP BTU CD CD CFM CO COTG w D EAT F FCO FPM HP Hw HWR HZ Kw LAT MI NO NTS OA PH POC RA RPM S SA SH SP T STAT TON TOT HT V VC VTR N WB WCO TRENCH DRAIN: J.R SMITH MODEL 9832 HIGH STRENGTH POLYESTER DRAIN BODY WITH MODEL 9870 -492 RESIN COMPOSITE GRATE, END CAPS, PVC SCHEDULE 40 BO ROM OUTLET AND 4' P —TRAP WITH TRAP PRIMER CONNECTION. JRAP PRIMER. PRECISION PLUMBING PRODUCTS MODEL P -2. BRASS BODY WITH "O' RING SEALS AND ADJUSTABLE SET SCREW. King County Department of Transportation CCMPRESSEE AIR ABOVE FINISHED FlOOR AMPERE (AMP AMPS) BRAKE HORSEPOWER BRITISH THERMAL UNIT CONDENSATE DRAIN CEIL:NG DIFFUSER CUBIC FE T PER MINUTE CLE_ANCUT CLEANOUT TO GRADE CC-0 WATER D+SCHARGE DRAIN ENTERING AIR TEMPERATURE FAHRENHEIT PP.:. (WET PIPE) FLOOR CLEANOUT FEET PER MINUTE HORSEPOWER HC' WATER HC' WATT RETURN F'REQUE'NCY KI LCWA -' LAVING AIR TEMPERATURE MINIMUM NLu3ER NC TO SCALE C.J'SIDE AIR P HASE (ELECTRICAL) POINT OF CONNECTION RETURN AIR REv LuTIONS PER MINUTE RPM SANITARY, SOIL SUPPLY AIR SE NSIBLE HEAT STATE. PRESSURE THERMOSTAT TONS OF REFRIGERATION TOTAL HFAT VENT, :)LT (ELECTRICAL) VOLUME DAMPER VEh; THRU ROOF WATT WET BULB WALL CLEANOUT MECHANICAL DRAWING INDEX M1.0 MECHANICAL DETAIL. SCHEDULE & SYMBOLS M' .0 1-NAG PUN 143.0 PLUMBING PLAN ZL'!K; EL KAY MODEL LR -1722, 18 —GAUGE —TYPE 302 —SELF RIMMING SINK WITH LK -99 DRAIN ASSEMBLY AND DELTA 27T3842 HEAVY DUTY GOOSENECK FAUCET WITH WRIS T —BLADE HANDLES. PROVIDE 17 GAUGE CP P —TRAP AND 1/2' ANGLE COMPRESSION VALVED SUPPUES. METRO TRANSIT DIVISION SOUTH BASE FACILITIES OFFICE /WORKROOM REMODEL MECHANICAL DETAIL, SCHEDULE & SYMBOLS 01-18-2002 DRAWING NO: M1.0 SHEET NO: OF 11 16 RECEIVED CITY OF TUKWILA JUL 2 5 2002 PERMIT CENTER MECHANICAL SYMBOLS AND LEGEND NUMBING HVAC SYMBOL DESCRIPTION SYMBO.. DESCRIPTION SYMBC DESCRIPTION A COMPRESSED MR TRAP PRIMER DIFFUSER. WITH FLDI CONNECTION o -- COLD WATER 0 ELBOW TURNED UP - � 004AUS T /RETURN REGISTER. WTD-0 FLEX CONNECTION CD CONDENSATE DRAIN (A8QV (MADE) C ELBOW TURNED DOVfN CD SENSOR WITH CONTROLLER F FIRE (WET PIPE) CONNECTION, BOTTOM --a VOLUME DAMPER -- HOT WATER CONNECTION, TOP a i„ , . , FLEXIBLE DUCT i - -- RECIRCULATING (HOT WATER RETURN) 1 BREAK UNE 12/20 DUCT sin., FlR T FlGURE is SIDE SHOWN SANITARY (ABOVE GRADE) E I PIPE CAP 11111111. FLEXIBLE CONNECTION - - -- . SANITARY (BELOW GRADE) I 1 �-- POINT OF CONNECTION DIFFUSER LINEAR I I I _ VENT 1 FLOOR CLEANOUT/CLEANOUT TO GRADE BALL VALVE !cEI 4— WALL CLEANOUT/CLEANOUT I ` UNION Q!] TRENCH DRAIN M ISCELLANEOUS r LATERAL 0 RISER/VENT THRU ROOF (VTR) MECHANKAL SYSTEM TO RELINN si. CROSS • PENDANT SPR1NlER //1/1////,' MECHMI{CAL SYSTEM TO BE REMOVED 7 `7 /// " s L .MQIE; SOME SYMBOLS IN THIS LEGEND MAY NOT APPEAR ON THE ACTUAL DRAWINGS. No. ECONOMIZER HOOD WITH REUEF DAMPER. ADJUST TO DELIVER 100 CFM OUTSIDE MR OR 100 X OUTSIDE AIR IN ECONOMIZER CYCLE. 36 X 25 HOLE THRU ROOF 1' 1/4' X 21 TO 12'• DUCT TRANSITION SUPPLY AIR VOLUME DAMPER ADJUST TO DELIVER 600 CFM REVISION r 1 4"0 NECK X 24" FACE CEJUNG DIFFUSER BY SHEET METAL FLASHING • — � RECEIVER PAC -1 BASE SEALING MATERIAL WOOD NAILER UNIT MOUNTING CURB REMOVABLE SHEET ]METAL COUNTERFLASHING FLASHING MEMBRANE (ADHERED TO CURB) STRUCTURAL SUPPORT AS REQUIRED SEE STRUCTURAL DRAWINGS FLEX CONNECTION (TYP) 18 1/8" X 11 1/2" TO 12"0 DUC' TRANSITION APP'D DATE HIGH — DOMED. CAPPED. GASKETED FASTENERS (APPROX. 18' [4.57 mm) O.C.. DEPENDING UPON WIND ZONE AND LOCAL CONDITIONS; MINIMUM TWO FASTENERS PER SIDE) SEISMIC BOLT THRU HEAT PUMP BASE AND CURB RETURN MR VOLUME DAMPER 12"11 INSULATED FLDOBLE DUCT (TYP) SEALANT (IF REQUIRED BY THE SPECIFIC SYSTEM) EPOM ROOF MEMBRANE 4" RIGID BOARD THERMAL INSULATION METAL ROOF DECK PREFAB CURB NOTES; 1. THE CURBS, TOP WOOD NAILER, AND SEAL STRIP ARE TO dE SUPPLIED BY THE CURB MANUFACTURER. 2. ATTACH NAILER TO DECK WITH SUITABLE FASTENERS. 3. WHEN POSSIBLE, THE MECHANICAL. UNITS SHOULD NOT BE SET UNTIL THE ROOF MEMBRANE AND FLASHING HAVE BEEN INSTALLED. PACKAGED ROOFTOP HEAT PUMP DETAIL SCALE:1 /2" 17928 BOTHELL EVERETT HWY SE, SUITE H BOTHELL, WASHINGTON 98012 ENGINEERS, LLC (425) 481-7735 FAX (425) 481-7692 CONTACT: OWEN NITTA JOB NUMBER: 013067 HVAC SCHEDULE PACKAGED ROOFTOP HEAT PUMP: TRANE MODEL WCD- 018— F— I —L —O, 18.400 BTUH TOTAL. 12.000 BTUH SENSIBLE COOUNG CAPACITY 0 85'F OUTDOOR DRY BULB. 67F OUTDOOR WET BULB. PROVIDE FARR 30/30M 2" THICK THROWAWAY FILTERS. EER =9.35. 9,500 BTUH HEATING CAPACITY WITH 17F OUTDOOR TEMPERATURE. COP =3.00. PROVIDE BAYHTRN105A, 3.74 KW SUPPLEMENTARY HEATER. ECONOMIZER KIT AND BAYCURB030M ROOF MOUNTING CURB. PROVIDE SINGLE POINT POWER CONNECTION. 44 MINIMUM CIRCUIT AMPS, 45 MAXIMUM OVERCURRENT PROTECTION DEVICE. 208-230V/193 /60HZ. QEILINP DIFFUSFR; TTTUS "OMNr NT MODEL. ALL F EEL CONSTRUCTION WITH FACE PANEL, LAY —IN FRAME WE 3 WITH Pk.ISMIC CUPS. #26 WHITE ANODIC ACRYLIC PAINT FINISH. m1E4 GRtL ; TITUS MODEL 50R, EGGCRI.IE CORE WITH STEEL FRAME AND BORDER TYPE 3 FOR LAY —IN CEIUNG, WITH SEISMIC CUPS. #26 WHITE ANODIC ACRYLIC PAINT FINISH. C ti EXPIRES: 7/8/02 J DESIGNED: DRAWN: CHECKED: RECOMMENDED: AP IBIS NO: woRK 11EGUESI: CONTRACT NO: G/515oG PLUMBING SCHEDULE ONE INCH AT FULL SIZE I....._ 1" IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: ABBREVIATIONS A AFF AMP BHP BTU CD CD CFM CO COTG w D EAT F FCO FPM HP Hw HWR HZ Kw LAT MI NO NTS OA PH POC RA RPM S SA SH SP T STAT TON TOT HT V VC VTR N WB WCO TRENCH DRAIN: J.R SMITH MODEL 9832 HIGH STRENGTH POLYESTER DRAIN BODY WITH MODEL 9870 -492 RESIN COMPOSITE GRATE, END CAPS, PVC SCHEDULE 40 BO ROM OUTLET AND 4' P —TRAP WITH TRAP PRIMER CONNECTION. JRAP PRIMER. PRECISION PLUMBING PRODUCTS MODEL P -2. BRASS BODY WITH "O' RING SEALS AND ADJUSTABLE SET SCREW. King County Department of Transportation CCMPRESSEE AIR ABOVE FINISHED FlOOR AMPERE (AMP AMPS) BRAKE HORSEPOWER BRITISH THERMAL UNIT CONDENSATE DRAIN CEIL:NG DIFFUSER CUBIC FE T PER MINUTE CLE_ANCUT CLEANOUT TO GRADE CC-0 WATER D+SCHARGE DRAIN ENTERING AIR TEMPERATURE FAHRENHEIT PP.:. (WET PIPE) FLOOR CLEANOUT FEET PER MINUTE HORSEPOWER HC' WATER HC' WATT RETURN F'REQUE'NCY KI LCWA -' LAVING AIR TEMPERATURE MINIMUM NLu3ER NC TO SCALE C.J'SIDE AIR P HASE (ELECTRICAL) POINT OF CONNECTION RETURN AIR REv LuTIONS PER MINUTE RPM SANITARY, SOIL SUPPLY AIR SE NSIBLE HEAT STATE. PRESSURE THERMOSTAT TONS OF REFRIGERATION TOTAL HFAT VENT, :)LT (ELECTRICAL) VOLUME DAMPER VEh; THRU ROOF WATT WET BULB WALL CLEANOUT MECHANICAL DRAWING INDEX M1.0 MECHANICAL DETAIL. SCHEDULE & SYMBOLS M' .0 1-NAG PUN 143.0 PLUMBING PLAN ZL'!K; EL KAY MODEL LR -1722, 18 —GAUGE —TYPE 302 —SELF RIMMING SINK WITH LK -99 DRAIN ASSEMBLY AND DELTA 27T3842 HEAVY DUTY GOOSENECK FAUCET WITH WRIS T —BLADE HANDLES. PROVIDE 17 GAUGE CP P —TRAP AND 1/2' ANGLE COMPRESSION VALVED SUPPUES. METRO TRANSIT DIVISION SOUTH BASE FACILITIES OFFICE /WORKROOM REMODEL MECHANICAL DETAIL, SCHEDULE & SYMBOLS 01-18-2002 DRAWING NO: M1.0 SHEET NO: OF 11 16 RECEIVED CITY OF TUKWILA JUL 2 5 2002 PERMIT CENTER 4J 0 No. • I • 22: C=m. *:';C C FM - •:LOCE r • _ : _.L .. REVISION • 20 X 10 -_ RELOCATE LIB AND FLEXIBLE DUCT f 14 X 10- r-r-�, -r 2S. X _ 18_ 50. !\• 1783 CFM ZONE F I I .zi 2 T yRU '•2 FROM ,�.,,•,._t • - t 70 CFM 100 C Q 1 30G CFL1 14 x CFM I , 32x ,18',SO 22 C _... Eli aNITORS ' CLOSET • cFM 185 " • 4 CFM 6G 8 X 10 ABOVE ROC F - • ` 1 i ALTERED CFM ,1 r---, • :CFM DEMOLITION PLAN M2.01 SCALE: 1/8* BY APP'D - : *OMENS DATE ALTERED I ' I 8 x 14 G ! .r CFM 195 �• F I h ' , OON T I I I i-12 X 8 CF,M. Zl O i CFM 21 GP bQSTINC DUCT CFA. x 6 6 X CFM 75 I CFM 210 RELOCATE LD AND FLEXIBLE DUCT CFM 230 .ZTING OFFICE CFM 230 RELOCATE LD REMOVE LD I. i .. 1 4 KGs EX 11 G OFFICE CAM 125 •I EXISTiNG VESTIBULE n. t: , : nnr. CFM 250 ! is ALTERED 4ULED • , . LUNCH Tof I '05 ' 1 7 - , -- T27 8�+( �. M 2 5t�ri I , FM 250' 13 X ' ' 10 .yv Ci'M 250 I; • 3 10" DLCT' TER{�INATES ' � _ �, RELO CATE -� _ _ ._- • _ -•• WITH RETURN SEND 18" lJ 10 .x 10 ASE • �r CFM 210 OFFICE S TN IG nr C 210 I! • 17928 BOTHELL EVERETT HWY SE, SUITE H BOTHELL, WASHINGTON 98012 ENGINEERS, LIZ (425) 481 - 7735 FAX (425) 481-7692 CONTACT: OWEN NITTA JOB NUMBER: 013067 REMOVE EXISTING LINEAR DIFFUSER AND FLEX DUCTS. RELOCATE TO NEW :ROOMS 103 do ALTERED OFFICE AREA 5 X 10 OFFICE �Il;f* : 1 . ALTERED OFFICE REBALANCE LD TO DELIVER 300 CFM PROVIDE NEW BALANCING DAMPER MERE) OFFICE REBALANCE LD TO DELIVER 150 CFM DESIGNED: DRAWN: CHECKED: RECOMMENDED: ?0 :Fm 7C CFW, 100 Cr C .. . . .. _ ;',7 ,J V 1 - •• t -• 1 7 „.. 225 CFM 1 I .. • ff��•-yy CFAI APPROVED: IBIS NO: Wows REQUEST: CONTRACT NO: i N r' n 370 CF1.4 37C CFM rittvG % KOH ' •8 X 10 ---" RELOCATED LD _ ! 185 CFM 8 x 10 • ZONE E:�CTS 2 Thpt. 12 FR'D✓ C.F.I -S S. ,:.�.. CFM RELOCATE FIRE SPRINKLER HEAD _2 32 X 18 SC -••i 14 - X 10 t 2720 cFM RELOCATE THERMOSTAT ai • .. , 1 --.. CFM 185, • CfM`135 0FM 185 • i • ONE INCH AT FULL SIZE 1' 1 I - IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: T� }. .;-1 7 I -1-1 t •• ■ i ' - • - - - 'GC CFM • • I ♦ 1 .. ... r . .-_r- ii -` 1 �.. - . VOMENS, TaEZTRION 14 X o '*- - 12 x F CLOSET 165 i I i ! I 4 � : FM, ' 35 CFt,1 60 • 28 X .18 .SO_ _. _ • NEW 1783 CFM ALTERED - i ) 20 LUJ fi ROO [ 1C3 - .•�RLj i •C aM 250 105 I 3" X 1 DUCT TERMINATES' WITH RETURN BEND 15' - ABOVE ROOF . RELOCATED LD King County Department of Transportation I I CF11 210 195 _ -l :F:.1 9` S X E 1}7 6 x 6-" Lj ' CFI./ '5 u 210 .. • 5 - G `CA 210 c .id 15.0 OFME 250____OFiA • 6 RELOCATE THERMOSTAT i CFM 230 OFFiCE CFM , : I t • - I f o • • RELOCATED 25C I \ 2 0 CF1.4 I i 1. j i - - -- AL2t - - - -1 1 I C6 4 U RELOCATED '�D 1 I R EL O CA TEO LD 7 1 - 11 50 CFM ;'• ' I r A 1 1! I IR : ? - 1 -: EW N DUCT CONN ,' `/ 1 X . .,, X .0 � ^ ' ,r-=8 X 10 METRO TRANSIT DIVISION SOUTH BASE FACILITIES OFFICE /WORKROOM REMODEL •`9�l4� h--- i OFFICE 01 t DQS11NG UNEAR DIFFUSERS (LD) CFIN AND DUCTWORK (TYP) QTY ut' C y FAm 250 OFFICE Aitai 'CF1lt 250 -..+j1 CFM 2? ibanva 1.11 CFM 210 NOTE: REBALANCE NEW AND EXISTING MR DEVICES TO CFM'S SHOWN ON DRAWINGS IN THE COOUNG CYCLE. CONTACT PAUL SCRENSON (LOCATED IN OFFICE 107) OF KC METRO FOR ASSISTANCE. MECHANICAL DEMOLITION & MECHANICAL PLAN r • 14'• N=CI x 24' FACE CEILB.G DIFFUSER. 604: CFM 14 SUPP_Y DUCT WITH VOt_G•ME DAMPER UP TO 21X11 - UNIT CONNECTION trip RETURN DUCT UP - 70 : 1'X1r UNr' CONNECTION WofiXROO 14•6 NECK X 24' FACE CD LING RETURN GRiti.E ), I C NORTH DRAWING NO: M2.0 SHEET NO: OF 12 16 RECEIVED CITY OF TUKWILA JUL 2 5 2002 PERMIT CENTER No. /- /r Hw, CW AND HWR BALL VALVES POC 1 /r NW. CW AND INWR TO 2 1/2" CW, 1 1/2" HW AND 3/4 HWR REVISION I\1 ozr�. s5U CONFERUCLE i co ENSTIM STORAGE BY I w /CW AND 1 1 2' V ON ABOVE CEILING D057TNG 6" COM�$SS AIi2 -, r • T. - .ASSEM$ � Ra ]' FROM ' : j EXt�TIN¢ wASTEtiWa R / RATO � ' . ...-_ - 1/2" COMPRESSED AIR DOWN EXfiSI lr APP'D DATE TRAP PRIMER WITH 12' X 1r ACCESS PANEL NORTH 3/4" COMPRESSED AIR FROM DUSTING WAIN 2' S. 2 V AND 1 /r CW UP THRU FLOOR 2" Wco 1/2" COMPRESSED AIR DOWN DUSTING 6 COTG COMPRESSED AIR REGULATOR ASSEMBLY RELOCATED FROM EXISTING WASTEWATER LABORATORY 17928 BOTHELL EVERETT HWY SE, SUITE H BOTHELL, WASHINGTON 99012 ENGINEERS, Lw (425) 481 -7735 FAX (425) 481 -7692 CONTACT; OWEN NITTA JOB NUMBER: 013067 EXISTING 6' SANITARY 2" V ABOVE CEILING DESIGNED: DRAWN: CHECKED: RECOMMENDED: SCALE:NTS 2' VTR, LOCATE 1O' -O" AWAY FROM PAC -1, SE SHEET 142.0 FOR LOCATION APPROVED: IBIS NO: Wows REQUEST: CONTRACT N0: SANITARY DIAGRAM PROJECT MANAGER: L POC 4' SANITARY TO 6" SANITARY PIPE SCALE! ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: I I" I WATER DIAGRAM SCALE:NTS King County Department of Transportation J � QMPRESSED AIR DIAGRAM TRAP PRIME -Z. PROVIDE 1: X 12" ACCESS PANEL — 1/2 CW 114 WALL FIN. SLR_ RELOCATED REGULATOR ASSEMBLY AND HOSE CONNECTION (TIT) 1/r METRO TRANSIT DIVISION SOUTH BASE FACILITIES OFFICE /WORKROOM REMODEL PLUMBING PLAN i /r CW BELOW SLAB TRENCH DRAIN P -TRAP 4 1/7' 1/r DATE. - 01 -18 -2002 DRAWING NO: M3.0 SHEET NO: OF 13 16 RECEIVED CITY OF TUKWILA Jul 2 5 2002 PERMIT ;EAtit.F•