Loading...
HomeMy WebLinkAboutPermit M02-163 - US HEALTHWORKSU S HEALTHWORKS 200 ANDOVER PARK EAST M02 -163 W CO 0 CO LU CO W W 0' 2 J lL Q: zN 8. te, Z' O Ua O VI o f- W w U. u. O wZ U= ~O Z Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: MIKE LEAHY Address: 727 S KENYON ST, SEATTLE, WA Contractor: Name: EVERGREEN REFRIGERATION INC Address: 727 S KENYON, SEATTLE, WA Contractor License No: EVERGI *201 D7 DESCRIPTION OF WORK: INSTALL EXHAUST FANS AND TENANT IMPROVEMENT ( DUCTWORK UNITS AND 2 FANS ARE EXISTING) Value of Construction: $4,100.00 Type of Fire Protection: N/A Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construct'. • • r the • - -'ance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0223100099 200 ANDOVER PK E TUKW US HEALTHWORKS 200 ANDOVER PK E, TUKWILA, WA TRI -LAND CORPORATION 1325 4TH AVE SUITE #1940, SEATTLE WA MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 763 -1744 Phone: 206 - 763 -1744 Expiration Date: 07/31/2004 Fees Collected: Uniform Mechnical Code Edition: Date: MO2 -163 08/16/2002 02/12/2003 Date: / $ 73.69 1997 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -163 Printed: 08 -16 -2002 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223100099 Address: 200 ANDOVER PK E TUKW Suite No: Tenant: US HEALTHWORKS Signature: Print Name: doc: Conditions PERMIT CONDITIONS 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 7: Manufacturers installation instructions required on site for the building inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. MO2 -163 Permit Number: MO2 -163 Status: ISSUED Applied Date: 08/12/2002 Issue Date: 08/16/2002 Date: Printed: 08 -16 -2002 Project Name/Tenant: L Signature: / Vlue of Mechan$1 Equipment: Site Address : Z orn Ae,cS over . City Sta Zip: eej k. 'r C., 1' Tax Parcel Numberr Property Owner: S 14 k---Q,1<-1 k---Q,1<-1 c.. , .ti n Phone: ( ) Street Address: 2s» /fir- J�Nrc/ City State/Zip: 9, 1c- c ev,\c' -1.--.-Ac-,4. �� Fax #: ( ) Contractor: r �YCrgre?e ?-el w rc tun ( r�cr Phone: (206) 765 )71-N Street Address: `� 12.7 5 �C�r..0 .5k . City State/Zip: �e�.�1'`e vv� `itsl v Fax #: (2 06) 7U� Z - Contact Person: Phone: (-e ) 7C-5 ' Street Address�Z_i S v �y� S)\-. ScacMc ' ity p: Fax #: (rt p()) /6 23tm 'BUILDING'O ' R ENT: Signature: / Date: l / 00 Z Print name: IDOL) � -,�,,� Phone: (-20 e- "763 I7 J Fax # : (Z o U ) 7 6.% 23ra�t Address: 7Z -7 3 /20-• %rod s L City /State/Zip: De q` t l e t k,N,4- 5 I v CITY OF Tr"(WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 STAFF USE ONI Y t Project Number: Permit Number. /40Z-4 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAUPERMIT.REVIEW AND APPROVAL REQUESTED: (TO BE FILLED :OUT BY APPLICANT) Description o to be done (please be specific): R f∎Ac ^S col'G Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT ! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once., Date application accepted: Date application expires: AP-a-Ay Application taken by: (initials) SAS 11/2/99 niech pern, ldnc ✓ U Submittal Requirements Floor plan and system layout „.•-oof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) .,— betails and elevations (for roof mounted equipment) and proposed screening 'Ueat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment - tiveighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Sin le Family Residence Heat loss calculations or Form H -6. Equipment specifications. installation of Gas Fireplace L Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. 11/2/99 nNscpnu.dnc Change -out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Caki • 40k ' 4116 Initials: SKS Payment Date: 08/16/2002 10:59 AM User ID: 1165 Balance: $0.00 City of P 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 Parcel No.: 0223100099 Address: 200 ANDOVER PK E TUKW Suite No: Applicant: US HEALTHWORKS Receipt No.: R020001193 Payment Amount: 73.69 Payee: EVERGREEN REFRIGERATION TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt Current Pmts Amount Payment Check 55380 73.69 MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Type Method Description Description Account Code 000/322.100 58.95 000/345.830 14.74 Perm it Number: MO2-163 Status: APPROVED Applied Date: 08/12/2002 Issue Date: Total: 73.69 Printed: 08-16-2002 Project: Type of Inspection: Address: 7—, A-PC: Date Called: Special Instructions: Date Wanted: IV a.m. ..m. Requester: Phone No: )t - INSPECTION NO. 71 INSPECTION RECORD I Retain a copy with permit P er(9 PER N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 4 2kproved per applicable codes. El Corrections required prior to approval. $4 . REINSPECTION REQUI ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: 4 .1 729 Date: •- -9 P ti wv r 16._ T ype of h „cf. 4...e.... Date c al is C le . ess: A fri coer " L -- - Special Instructions: A 4(j El v (M' Date 1 n Request r: 7 rY) Phone No: 2 Q° - , • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 El Approved per applicable codes. $47.00 REINSPECTI FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. lEl orrections fequired prior to approval. COMMENTS: /1 e( 1- 8 7.e./t h Receipt No.: IDate: >' 1; u; X!' nti +t;. "= uz�:;,3a:.ii:.u.ti:iii.:�. Er:i�b "• ^:7. +.i� +;:e e.... i':k:: ?t . INSPECTION RECORD - 9. Retain a copy with permit INSPECTION NO. ITY OFTUKWILA BUILDING DIVISION 300;Southcenter.: Blvd :,' #100, Tukwila, WA 98188 (206)431 -3670 Project :, .., Address: ' Type of Inspection: 5417 ,leedti Date Called: Date Wan d: 7 -74!" -0 Requester: Ph � 2 r(,) Approved per rd Corrections required prior to approval. COMMENTS:. t�rJ 4,4e S CAUCA O p 44e C 1 11 t) VVP i 71711 100 r I h G In t k . � 1) - -- il i'Ou1�rr' IA) 4 1 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: u:4 Pro Ct: Type 99nspecti n: Address: ' 2.00 AVIa;OVA etc E., 5f( Date called: /s- Special instructions: 904 "� �- p�M` / ' f I C a Date wanted: a.m. ����c a el Requester P 9 acc) 975- 317 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Approved per applicable codes. Li Corrections required prior to approval. COMMENTS: Inspector: Date: (7-7,42 $47.00 REINSPECTION FIE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: r",}a.�t�s' ^.ta'r. - .�.MrsR��1:..k ,�t,+ Pct' s 5� `� tuYd"��)•,4`+ . _ �..1s.L L P' X.... .1. Nia....Y,.S,n.}'iS��`S�� INSPECTION NO.' • CITY OF TUKWILA BUILDING DIVISION 6 Southcenter Blvd :, #100, Tukwila, WA 98188 Pr . sect: lV.1:r iri'�, ecial Instructions: Approved p INSPECTION RECORD Retain a copy with permit applicable codes. Type of Inspection: LC Date Called: v�r ^a pr ,$d'h= '��:-s.`Y� "'4 ";. ;4' " Cu i •af:ti r G'Oha:A''+.�N`L,'•<• ?,k it •.- .1: ;�:^) -?ru 1. ':"''aY.s :r<i Y;r4 (206)431 -3670 Date Wanted: f Requ stet: Pk one Nos, 79 •-9 Corrections required prior to approval. COMME - r frvw lnsp $47 pa REINSPECTION E REQUIRE ' Prior to inspection, fee must be at b300 Southcenter :Ivd., Suite 00. Call to schedule reinspection. ipt No. Date: 'Date: 00 N0 co tu W0 QQ � v . I— 111 Z � W 0 co 0— OI— LL/ u j u. O tl. U= O~ z Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: FINALAPP.FRM City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief ZU 2 Permit " 0 rno- - I (01- Project Name \ . \ e A \�t� W 0 c k.S v�~ 5 1(0 Address Y! ()t) (rte r\00 -xc E Suite #( 9' Retain current inspection schedule Needs shift inspection Approved without correction notice Approved -with correction notice issued TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM 9( Authorized Signature Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575 -4404 • Fax: 206 - 575.4439 Project Info Project Address U.S. Healthworke, Andover Plaza TI, Date 08/09/02 CFM 200 Andover Park Bast #6, N8, For Buildirnt @gpt CITY OF TUKWILA AUG 1 2 2002 PERMIT CENTER Flow Control Tukwila, WA. Applicant Name: Evergreen Refrigeration Inc. Applicant Address: 727 S Kenyon Street Applicant Phone: Seattle, WA 98108 Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP HP /BHP Flow Control Location of Service 8P 1 -5 'ROAN 890 90 0.2 0.5A C.V. Mounted on Ceiling Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency echanical Summa • • MECH -SUM 2001 Washington Slate Nonresidential Energy Code Compliance Forms Project Description Duct Tenant Improvement only. Install distribution ductwork, and reuse exiting Briefly describe mechanical system ductwork. All rooftop HVAC Units and two exhaust fans are existing. Install type and features. three new exhaust fans. ❑ Includes Plans Compliance Option 2001 Wa ^''lp ton State Nonresidential Ener Code Com•t ~'ce Form FILE COPY t;',c r',;n Ch.cok : r�. \mvols are June 2001 • KJM Simple System O Complex by -stem O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the! plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1, 14 -2 or 14 -3. 3 If equired. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). C4�� 100 409 ( Z -/63 .an.. rrot:ct w, t; �wU: eSS'. 1; ca6tf✓ tiifrw+([,ici'.,X�':XIGat'sr. <s� d iFisE1r: +k'v,i:rtSC+C.ktx:;94;%i�,3'XG. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: Constant vol? fl Split system? Air cooled? Packaged sys? fl Economizer included? <54,000 Btuh or 1900 cfm? If Heating Only: <5000 cfm? <70% outside air? Mechanical Summ. (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. if not, either the Complex System or Systems Analysis Options must be used. System Type Heating Only Yes Yes► 2001 Wa n ton State Nonresidential Ener• Code Comr"knce Form Heating/ Cooling or Cooling Only Reference Section 1421 Yes—► Yes Yes Yes Yes Reference ` Section 1423 / Reference Section 1420 Yes Simple System Yes ► Allowed T Use Complex Systems Reference Section 1430 Complex Systems Complex Systems requirements are applicable to this project. Mechanical Permit • . ns'Checklist MECH -CHK 2001 Washington State Nonresidential Energy Code Compliance Forms June 2001 - KJM Project Address U.S. Healthworke, Andover Plaza TI, Date 08/09/02 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& cig. List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans Ml yes 1412.2 Deadband control Indicate 5 degree deadband minimum M7 n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types Ml yes 1412.4.1 Dampers Indicate damper location and automatic controls Ml n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans Ml n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Operation Indicate 100% capability on schedule n.a. 1413.2 Control Indicate controls able to evaluate outside air n.a. 1413.3 Integrated operation Indicate capability for partial cooling 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary Ml yes 1414.2 Duct insulation Indicate R -value of insulation on duct Ml n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.1 &2 Drawings & Manuals Indicate requirement for record drawings and operation docs. Ml yes 1416.3.2 Air Balancing Indicate air system balance requirements M1 n.a. 1416.3.3 Hydronic Balancing Indicate hydronic system balance requirements yes 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report Ml yes 1424 Separate air sys. Indicate separate systems on plans M7 yes Mech. Sum. Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2001 Washington State Nonresidential Energy Code Comrl'-+nce Form no is circled for any question, provide explanation: 2001 Washin ton State Nonresidential Ener• Code Comn'tance Form Mechanical Permit ' .ns Checklist 2001 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK June 2001 - KJM Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1 through 14 -3. If a nationally recognized certification program exists for a product covered in Tables 14 -1 through 14 -3, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu/Ft may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2001 Washin ton State Nonresidential Ener• Code Comn'tance Form Mechanical Permit ' .ns Checklist 2001 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK June 2001 - KJM Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1 through 14 -3. If a nationally recognized certification program exists for a product covered in Tables 14 -1 through 14 -3, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu/Ft may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) DEPARTMENTS: itt , P 47 ' Building �ivisii en i Public Works ❑ i RMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -163 PROJECT NAME: U.S. HEALTHWORKS SITE ADDRESS: 200 ANDOVER PARK EAST #6 X Original Plan Submittal DATE: 08 -12 -02 Response to Incomplete Letter # Response to Correction Letter # Revision # — After Permit Is issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete (� rev 4L J-f4- Fire Prevention Planning Division ❑ Structural ❑ Permit Coordinator Incomplete DUE DATE: 08 -13-02 Not Applicable ❑ Comments: Permit Center. Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route gr Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 09 -10-02 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY ACTIVITY NUMBER: MO2 -163 DATE: 08 -12 -02 PROJECT NAME: U.S. HEALTHWORKS SITE ADDRESS: 200 ANDOVER PARK EAST #6 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # _ After Permit Is Issued DEPARTMENTS: Building Division Public Works -- Complete T3 Incomplete ❑ APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2.28 -02 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08 -13-02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review e u' ed ❑ No further Review Required REVIEWER'S INITIALS: F�'C.4 f DATE: DUE DATE: 09 -10-02 Approved Er Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: v ` aJ' ` �Z Permit Center Use Only CORRECTION. LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: I w 3 CO 0 v O 0 • W w a g_ co F _ I- O Z w M • N 0E- W W I- u' W Z U= O Z ti PERMIT NO.: M 0t I MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 2 Pre - construction ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 610 Chimney Installation /All Types ❑ 700 Framing ❑ 1080 Woodstove ❑ 1090 Smoke Detector Shut Off 1100 Rough -in Mechanical 1101 Mechanical Equipment/Controls 1102 Mechanical Pip/Duct Insul 1105 Underground Mech Rough -in 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final ❑ 4015 Special -Smoke Control System CONDITIONS 14 10001 No changes to plans unless approved by Bldg Div ❑ 1000 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I 10005 All permits, insp records & approved plans available ❑ 10014 Readily accessible access to roof mounted equipment ❑ 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: it `L °(,LekiajDje FEES Plan Reviewer: - Permit Tech: Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) i" Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'l Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Date: gj/( 4�QZ Date: S - ;4 II / !.. •/IV19YM ACTIVITY NUMBER: MO2 -163 PROJECT NAME: U.S. HEALTHWORKS SITE ADDRESS: 200 ANDOVER PARK EAST #6 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # — After Permit Is Issued DATE: 08 -12 -02 DEPARTMENTS: Building Division Public Works 0 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Incomplete ❑ REVIEWER'S INITIALS: 51 APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2.28.02 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural effiwahry Planning Division Permit Coordinator DUE DATE: 08-13 -02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Struc tral Review Required ❑ No further Review Required DATE: S*"5 Iik\O DUE DATE: 09-10 -02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z r W U O WO s W WO J LL ' : CO alIJ Z W 2 p U O C O !- W V . 1 1 - . O w -- O I z SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION CFM S.P. DUCT SECTION SUPPLY PHASE HP/A DUCT SECTION -RETURN/EXHAUST 7 RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT L VD VOLUME DAMPER 0.2 ZD ZONE DAMPER © MD MOTORIZED DAMPER - 4 FD FIRE DAMPER - � FSD FIRE /SMOKE DAMPER (1205 POWER REQ.) 0.5 A CEILING RADIATION DAMPER BROAN SD SMOKE DETECTOR 0.2" T THERMOSTAT 0.5 A S SENSOR ° R REFRIGERANT LINES 0.2" G NATURAL GAS LINES D5 EF5 CEILING DIFFUSER (SUPPLY) DUO 9O CEILING DIFFUSER (RETURN /EXHAUST) M : EXHAUST FAN. (CEILING MOUNTED) INLINE FAN 08 PROPELLER FAN RECEIVED CITY OF TUKWI[ \I/ - SIDEWALL DIFFUSER AUG 1 2 2t L DUCT FITTING PERMIT GENIE /U B.O.J. 12' 2'-� DATUM FP 2 UNIT TAG O. DUCT RISER EXHAUST FAN-SCHEDULE MARK MANE. MODEL CFM S.P. VOLTS PHASE HP/A NOTES EF 1 BROAN S90 90 0.2 115 1 0.5 A EF 2 BROAN S90 90 0.2" 115 1 0.5 A EF 3 BROAN DUO 90 0.2" 115 1 0.5 A EF4 BROAN S90 9D 0.2" 115 D5 EF5 BROAN DUO 9O 0.2 ". '115 1 USA COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.1. OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 14162. ALL HVAC SYSTEMS. SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.3. FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS AS DEFINED IN TNNUEC SECTION 21)1 HVAC CZSRYROL SYSTEMS SHALLET BES7StCALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS 'AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4.1. I' FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.4.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.4.2.1; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFIOATE OF OCCUPANCY PER WSEC SECTION 1416 4 9 91 AND 1416 4 2 3' AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4.2.2.2 FILE COI I understand that the Plan Check approvals are subject to errors and OrtItSSiCTIS and approval of plans does not aurhorize vioIatIon of any adopted code or ordinance. PvaceIpt T con- tractors copy of approved p! ns acknowledged. By Date Mot-i0 Permit No. ' W Z REVISIONS NO CHANCES SHALL BE •6AOE TO �. C> OF X wITHOUT aa, ° TUSI u4 A W(LIDIra ANEM f_, SEPARATE PERMIT REQUIRED FOR: MECHANICAL [✓7 ELECTRICAL RICAL g PLUMBING (GAS PIPING CITY OF TUK ILA BUILDING DIVISION GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2' TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD L'TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER UMC 1997, SEC.601.4. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE I/O INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -18. I.5 ALL DUCT GAUGES PER TABLE 6 -A 6 TABLE 6 B OF 1997 UMC. 1.6 ALL DUCT SUPPORTS PER TABLE 6-E OF 1997 UMC. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED. ON ALL BRANCH DUCTS OR DIFFUSERS. DUCT INSULATION 2.1 .INSULATE OR LINE DUCTWORK PER WA. STATE. ENERGY AND MECHANICAL CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL R U.M PENET RATIONS, INCLUDING WEATHERPROOF SEALING .AND FIREPROOF LINING PE GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ER13EFORE FRAMING OPENINGS. GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. GENERAL:= ONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. GENERAL CHANICAL WORK. CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR ME GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. GENERAL CONTRACTOR TO LEVEL FACTORY BS PROVIDED BY ALL CANT - STRIPS AND CUR INSULATIOALL N AND S EAL CUR AGAINST LEAKS. ERI, PROVIDE GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIF ED FOR HVAC INSTALLATION: GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORY: INSTALLATION IN ACCORDANCE WITH TABLE 6A OF UNIFORM BUILDING CODE (1997 EDITION), WHERE REQUIRED BY SECTION 711 OF UBC (1997). ELECTRICAL L.I ERI TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL ONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS. DISCONNE'TS. AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELERICA CONTRR T VEIY QUIPME SZE LOADS AND LOCATIONS WI TH ERI i1E CHANICAL P O AND RF WITH E FIELD C ONDITIO NS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERI TO PROVIDE. 7 -DAY NIGHT SETBACK. PROGRAMMABLE TYPE T -STAY WITH CAPABILITY OF 5 °F DEADBAND: 4.6 ERI TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 3' ABOVE HIGHEST POINT OF INTAKE. 5.3 CONDENSATE. DRAINS AND DRAIN LINES BY ERI., DRAIN TO ROOF WITHIN 12' OF UNITS. 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 ENERGY CODE COMPLIANCE 6.1 AT MINIMUM, EACH FLOOR IS TO BE .CONSIDERED A SEPERATE ZONE VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6 2 OUTSIDE AIR INTAKES, EXHAUST OUTL ETS, AND REL OTLTa IOU N CONDITIONED SPACES SHALL BE EM IS O WITH DAMPIEF D ERS WHI E C - H S AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR EGON..11SERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 10096 CAPABILITY, CONTROL AND OPERATION OF THE ECONOMISER SHALL CC,PLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM DETECTORS SHALL BE LOCATED IN THE MAIN SUPPLY AIR PER UMC 1997 SEC. 608. REVISIONS'. NO DATE MO - /43 ITEM DRAWING DATE: 08 -09 -02 DWG. BY: GN CHK. BY: ML /NB JOB NO.: 025051 DWG. FILE: USHEALTHMI' 0 0) 00 N co co co O HOLOSEIL NJ- Hain RESERVED. TFE N£ SHALL NM RMAW TIE R✓6£ilY tr EVE - SORE. � EEP „Tm DE IC PMT[ 21139:1F LISFED aniEtvISE USED WORM TIE PRIM Trot To EvesxEM PEAUGMATESs DE ..>s otIITALT VIM II£ FRCVS WHAMS Or SEEM- ATIONS SHALL CESEITMTE COCIASIVE EV1IDCE FCCEPTMC< 6 TF£¢ RESTSSiID2 • COVE II PROGRESS PRINTS - NOT FOR CONSTRUCTION [i] APPROVED FINAL DRAWINGS El AS BUILT DRAWINGS CONSTRUCTION DRAWINGS EVERGI201 D7 _ Nor II I � 11 11 �� �7�1u!�G��������� . —�L— - II N 1so, L , MEN 6 �� No 7 IT 1 0 - � him.- SI' RAE 709 _ MI j �' j! mow I1rIl'iH , AI s a zoo % = i'l 111 R. R . 0 j ' 70 8 : ^ 1 1 _L ti� Ina ,i' ; ® E ;' rill _ °_ I i ' � i IM �I F--_J II�� w(U f 111 ►'� �J ' t °i 1 ° ' f ( °I ► u � ' ii �v`� 1 1 MA, ca ,. e.,..�ono rn J �_L! � ► ittali� I per,... � I 11 t r S T • . / "" s I .';S� f ,,I 1111 j °' a _ I� ■ 11 '� 1 iso "' 3 1 j �� � �� � 1 L., 111 1i�i�I� ... ' 17001 tw�I�' Iiiiii 10L 1� . , 1 8 — I - 4' a ®; _ _J 17E • • ©m pianitxximi 1 tiN.�4® �1111I n'' r I. t�I F \�M, ! 11111111 �, li me r ro_ %'�111=l� �Le......,,,.. Ili , •® .1 —di - VP' I'm 10o r f wRE , 0 11 1 r' EN t (I _� _ J [ c ill I ,,, �'' �., Et ls�� II iu III JIII‘.�IrsaT I —.1 :EN - t M.7� 8 , j ' 2 -12T9N t ; A 'Y UI , I I j I i ask Raw I L_ in 1 u ao III ! A irerr ,101•11;h11 U �1m ;� � 1 ECEP1 ON E Ia ,: i t 4 . x• I; 02 12 I A 17 Tbrg, lei EN 'f . iti,! ,,..,, ` Y id 11 1_ p 7 7d' iik�G 300 175-1 /).. `' 1 I 11Cj KK-TT 3001 n 1 1 1 L -1 1 1 r`1 I� j 1 _,, : .-I PUB... Pt OrtSMORV@ T. NOT ERA.. VOWS/RWS. SEAS. MEM RGEEN RETREG tl TEM TIG M PART TFETE6 LOSED OR EISSTAMTE0 TO imam SSA RO- LM. OR ME M. LO ED ,RhYR THE Phi WRITTEN OC@1(P 6 N0 MPfLWME mWf- - ilroc VON T. MOW II6 Ot S- TID6 SHALL CONSTITUTE CEPCLEROVE EVE.= s 06EPIMfE ff TPESE fESiRICiTD6 fit lcf Iv I<l • ❑ ❑ ❑ REVISIONS NO DATE ITEM DRAWING DATE: 08 -09 -02 DWG. BY: GN CHK. BY: ML /NB JOB NO.:' 025051 DWG. FILE: USHEALTHM2 M2 / „ FLOOR PLAN SCALE : 1/8" = 1' -0" :' - 8 KEYNOTES: /226 Z —I6 3 O j RTU 1,2,3,4 ARE EXISTING, DUCT TENANT IMPROVEMENT ONLY • EXISTING RESTROOM EXISTING FANS O DISTRIBUTION DUCTWORK FROM RTU 3 8.4 IS EXISTING O 4 DRYER VENT TO ABOVE RECEIVEC CITY OF TUKWILA AUG 1 2 2002 PERMIT CENTER PROGRESS PRNTS - NOT FOR CONSTRUCTION HVAC PLAN FAX(206) 7'63 - 2389 APPROVED FINAL DRAWINGS (206) 763 - 1744 CONSTRUCTION DROINGS EVERGI201 D7 AS BUILT DRAOMNGS