Loading...
HomeMy WebLinkAboutPermit M02-164 - US HEALTHWORKSU. S. HEALTHWORKS 200 ANDOVER PARK EAST, #8 M02-164 c4 2 U UQ cow W0 2Q Z W tu D D. O -; �H W uJ O wz Parcel No.: 0223100099 Address: 200 ANDOVER PK E TUKW Suite No: Tenant: Name: US HEALTHWORKS Address: 200 ANDOVER PK E #8, TUKWILA, WA Owner: Name: TRI -LAND CORPORATION Address: 1325 4TH AVE SUITE #1940, SEATTLE WA Contact Person: Name: MIKE LEAHY Address: 727 S KENYON ST, SEATTLE, WA Contractor: Name: EVERGREEN REFRIGERATION INC Address: 727 S KENYON, SEATTLE, WA Contractor License No: EVERGI *201 D7 DESCRIPTION OF WORK: INSTALL NEW EXHAUST FANS AND TENANT IMPROVEMENT Value of Construction: Type of Fire Protection: Permit Center Authorized Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 $4,100.00 N/A e MECHANICAL PERMIT MO2 -164 Permit Number: MO2 -164 Issue Date: 08/16/2002 Permit Expires On: 02/12/2003 Phone: Phone: 206 763 -1744 Phone: 206 - 763 -1744 Expiration Date: 07/31/2004 Fees Collected: Uniform Mechnical Code Edition: Date: $46.50 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe . ance of work. I am authorized to sign and obtain this mechanical permit. Signature: `! Date: S / 16 !0 Z_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 08 -16 -2002 doc: Conditions xia‘s City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223100099 Address: 200 ANDOVER PK E TUKW Suite No: Tenant: US HEALTHWORKS Permit Number: MO2 -164 Status: ISSUED Applied Date: 08/12/2002 Issue Date: 08/16/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 4: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. Print Name: k C G 4 -t7t■/ PERMIT CONDITIONS I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: - Date: MO2 -164 Printed: 08 -16 -2002 Project Name/Tenant: tJ s �CclW� vw rlts R' e • ' , GENT: Valu Mechanical Equipment: f a of 1 1 H i i c.x7 Site Address : oo City State/Zip: Tax Parcel Number: aA .. k . 0 Property Owner: ES Q , \1„H or1:S � City State/Zip: , Phone: ( ) Fax #: ( Address: '7 Z7 Street Address: T c A ove.r R., r• k_ ��)c Contractor: f j L �l ! 9v ut • Phone: (Z..-6 ) Street Address: Z� 5 ���7b� 5'k - ��J�� {�� City State/Zip: Fax #: (' ) - 7 G 7...�`� Contact Person: h1 `` � Phone: ( ) �eet Address: City State/Zip: Fax #: ( "BUILDING OWN R' e • ' , GENT: Signature: l h ZIP' g / (--� ( . Print name: I aA .. k . 0 Phone: ( -717149 �b ) 7 �9 Fax #: (') - 7"6' �.� ? -., Address: '7 Z7 ICen.1n� Ste' City atep: / St/Zi Se+ � �l ! 9v ut • CITY OF '1KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 R srnrr SE ONI Y Project Number: Permit Number: 003 -14 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL; PERMIT REVIEW AND APPROVAt REQUESTED: (TO BE FILLED, OUT BYAP'LICANT) Description of work t be done (please be sp ic): � -�,.���� 7 T. Current copy. of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Pawn Date application expires: Application taken by: (initials) SOS U/2/99 meth permiidoc ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Oi -4% Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal 11/2/99 miscpn(.doc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. allz ta∎ N• 1 TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223100099 Permit Number: MO2 -164 Address: 200 ANDOVER PK E TUKW Status: APPROVED Suite No: Applied Date: 08/12/2002 Applicant: US HEALTHWORKS Issue Date: Receipt No.: R020001194 Payment Amount: 46.50 Initials: SKS Payment Date: 08/16/2002 11:02 AM User ID: 1165 Balance: $0.00 Payee: EVERGREEN REFRIGERATION Payment Check 55380 46.50 Current Pmts Amount MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Type Method Description Description Account Code 000/322.100 37.20 000/345.830 9.30 Total: 46.50 Printed: 08 -16 -2002 INSPECTION RECORD Retain a copy with permit ION NO. ITY OF TUKWILA BUILDING DIVISION 6300,Southcenter.; Blvd' ,4100, Tukwila, WA 98188 (206)431 -3670 Special :Instructions: Type of Ins ection: )/r".t/L Date Cal ed: Date Wanted;,. Ll �,,, — Requester: Phone No: proved per applicable codes. O Corrections required prior to approval. COMMENTS:. • $4 : REINSPECTION F E REQUIRED. Prior to inspection, fee must be paid at 1300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No :: 'Date: P Vtec We Cc f fi l WO✓kST Ins of Shut ( of Addre 2 (5 A'- )'IOVer pt Date Caile / ij Special Instructions: Y,.i (I . !^ Date Wa Z7 L f ( U e Re u ter: q� Ph 0 .— / L I 0 _ ) Z F i ..e — ri INSPECTION RECORD ( �' J Retain a copy with permit N b L' I INSPECTION NO. PERMI CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: El $47.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project:, ::: - . / 5 : A Z.; Z IfMFe< Type of Inspection: ( — 5 1/1- /1 0/ Address::. "' - ' r Date Called: -/7---O. Special Inst uctions: /�? 1% r f7QE , , 1", - ' 6v /Ge- - Date Wanted: 9 — /, -- 0 .-- a.m. Requester: 1`�?' Phone No: Y _<=2, INSPE ON NO. :,OF;TUKWILA BUILDING DIVISION 5 300.Southcenter Blvd:, #100, Tukwila, WA 98188 COMMENTS: Approved per applicable Inspector: INSPECTION RECORD Retain a copy with permit (206)431 -3670 orrections required prior to approval. I Date_\o � �' $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at.t300 Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 'Project: VS Th u 10 r k4-- Type of Ins) tion: - ----b- A on Andover &E. Date called: Special instructions: . . ao Date wanted: -4 1 — (),. a.m Requester ii &7m mi 3173 t INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY,Of TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: rep c. 1 Tor t v1A rsr)u U . V - Pl r1 \ Qj ( v Ph . S hnoL . c\-e'° c o o ' sht - O -N t.0` \‘ `-e Y`eit ; - eU( \ (■oar '40 1>nut . NOI trac w; 1- , re et? oa r' 4 W\QV1- - - Inspector: ¥ Date: (I — I-9- 02 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: AiiiirovedperaPplicable codes. a. • INSPECTION RECORD Retain a copy with permit INSPECTION NO; • , CITY OF TUKWILA BUILDING DIVISION 6300 S outhcenter Blvd, #100, Tukwila, WA 98188 (206)431-3670 Project: 1711,00rIcs -4 dr e5b. An pt. e Special Instructions: • Type of Inspection: C — 1 -4 0 Of_ Datet a r d: (0 Ocl } Date W Not, (6 1 oa n RequM (...4 ci• "74 -- (c)79 —31 3 COMMENTS:-; • • To - I 1. 7 • • . El Corrections required prior to approval. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be :paid at t300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: ICDP — t.4 ' • friOL/0-<_ --:-•••••■•` C ity of l u lla Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name \jS . L P t, \C () c S Address 200 (\r" C bo a ,, Retain current inspection schedule Needs shift inspection Approved without correction notice Approved• with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: FINALAPP.FRM Authorized Signatur'e 510 Permit Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 - 575.4404 • Fax: 206 -575 -4439 NOIMISIMMONNIUMINimisonewatetemans Project Info Project Address U.S. Healthworka, Andover Plaza TI, Date 08 /09/02 CFM 200 Andover Park East E6, Me, For Building Dept. Use RECEIVED CITY OF TUKWILA AUG 1 2 2002 PERMIT CENTER Flow Control Tukwila, WA. Applicant Name: Evergreen Refrigeration Inc. Applicant Address: 727 S Kenyon Street Applicant Phone: Seattle, WA 98108 Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Control Location of Service E! 1 -5 BROAN 890 90 0.2 0.5A C.V. Mounted on Ceiling Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency 2001 Washington Stale Nonresidential Energy Code Compliance Forms ❑ Includes Plans 2001 Wa " ton State Nonresidential Ener Code Com•II- Form Mechanical Summar MECH -SUM Project Description I Duct Tenant Improvement only. Install distribution ductwork, and reuse exiting Briefly describe mechanical system ductwork. All rooftop HVAC Units and two exhaust fans are existing. Install type and features. three new exhaust fans. . FILE COPY June 2001. KJM Compliance Option Q Simple System 0 Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1, 14 - or 14 -3. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). CITY Of TUKt'&A APPROVED AUG 1 5 2002 tk: t_U ft122/ System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <54,000 Btuh ❑ Economizer included? or 1900 cfm? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only Yes Yes ■ 2001 W; �t ton State Nonresidential Ener. Code Comr'''nce Form Heating/ Cooling or Cooling Only Reference Section 1421 Yes Yes—O. Yes Yes Yes Reference Section 1423 Simple System O. Allowed Reference Section 1420 0 Yes • Reference Section 1430 Complex Systems Complex Systems requirements are applicable to this project. Agima Mechanical Permit Plans 2001 Washington State Nonresidential Energy Code Compliance Forms Checklist MECH -CHK June 2001 • KJM Project Address U.S. Healthworke, Andover Plaza Ti, 'Date 08/09/02 The following Information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule n. a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1412 HVAC controls yea 1412.1 Temperature zones Indicate locations on plans Ml yes 1412.2 Deadband control Indicate 5 degree deadband minimum Ml n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types M1 yes 1412.4.1 Dampers Indicate damper location and automatic controls Ml n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yea • 1412.7 Balancing Indicate balancing features on plans M7 n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Operation Indicate 100% capability on schedule n.a. 1413.2 Control Indicate controls able to evaluate outside air n.a. 1413.3 Integrated operation Indicate capability for partial cooling 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary Ml yes 1414.2 Duct insulation Indicate R -value of insulation on duct Ml n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.1 &2 Drawings & Manuals Indicate requirement for record drawings and operation docs. Ml yes 1416.3.2 Air Balancing Indicate air system balance requirements Ml n. a. 1416.3.3 Hydronic Balancing Indicate hydronic system balance requirements yes 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report Ml yes 1424 Separate air sys. Indicate separate systems on plans Ml yes Mech. Sum. Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2001 W ngton State Nonresidential Ener no is ciirciea for any question, provide explanation: Code Corr ' ice Form 2001 W 'n ton State Nonresidential Ener. Code Come' - -Ice Form Mechanical Permit P ans Checklist 2001 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK June 2001 - KJM Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1 through 14 -3. If a nationally recognized certification program exists for a product covered in Tables 14 -1 through 14 -3, and it Includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by Individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. • •..1: ...u, A ,2, 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu /h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2001 W 'n ton State Nonresidential Ener. Code Come' - -Ice Form Mechanical Permit P ans Checklist 2001 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK June 2001 - KJM Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1 through 14 -3. If a nationally recognized certification program exists for a product covered in Tables 14 -1 through 14 -3, and it Includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by Individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. • •..1: ...u, A ,2, 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu /h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) ACTIVITY NUMBER: MO2 -164 DATE: 08 -12 -02 PROJECT NAME: U.S. HEALTHWORKS SITE ADDRESS: 200 ANDOVER PARK EAST #8 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Buil ing Division Public Works Documents/routing slip.doc 2.28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP BSID C1 P / - Fire Prevention Structural ❑ REVIEWER'S INITIALS: PERMIT Cnr)Rr (nri Planning Division ❑ Permit Coordinator DUE DATE: 08-13-02 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [ Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTI Please Route ,L.,7, Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 09-10 -02 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Building Division Public Works REVIEWER'S INITIALS: Approved Notation: Er Documents/routing slip.doc 2-28-02 APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -164 DATE: 08 -12 -02 PROJECT NAME: U.S. HEALTHWORKS SITE ADDRESS: 200 ANDOVER PARK EAST #8 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # _ After Permit Is Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 08 -13 -02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Revie equired ❑ No further Review Required Er 5 - - 13 -02 DATE: DUE DATE: 09 -10 -02 Ap jov . with Conditions ❑ Not Approved (attach comments) ❑ • DATE: g Permit .. Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT NO.: M D Z / & MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 2 Pre - construction ❑ 50 WSEC Residential ❑ 60 WA Ventilation /Indoor AQC ❑ 610 Chimney Installation/All Types ❑ 700 Framing ❑ 1080 Woodstove 1090 Smoke Detector Shut Off 1100 Rough -in Mechanical 1101 Mechanical Equipment/Controls ❑ 1102 Mechanical Pip /Duct Insul ❑ 1105 Underground Mech Rough -in ❑ 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final ❑ 4015 Special -Smoke Control System CONDITIONS 10001 No changes to plans unless approved by Bldg Div ❑ 10002 Plumbing permits shall be obtained through King Co ❑ 10003 Electrical permits obtained through L & I O 10005 All permits, insp records & approved plans available ❑ 10014 Readily accessible access to roof mounted equipment ❑ 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces O 10042 Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: (.4 j /Lat/ by c.)/ k/ f FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor-mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP/1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'l Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Permit Tech: tv 2 I W 00 N0 (0W WD g a gt d . O 0 � 0H W UJ I- -- .. H Z ACTIVITY NUMBER: MO2 -164 DATE: 08 -12 -02 PROJECT NAME: U.S. HEALTHWORKS SITE ADDRESS: 200 ANDOVER PARK EAST #8 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TOES /THURS ROUTING: Please Route ❑ S REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Review Required ❑ No further Review Required �(q REVIEWER'S INITIALS: Revision # After Permit Is Issued DUE DATE: 08 -13 -02 DATE: Planning Division Permit Coordinator Not Applicable ❑ DUE DATE: 09-10 -02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: SYMBOL LEGEND MARK ABBV. DESCRIPTION CFM DUCT SECTION SUPPLY VOLTS DUCT SECTION - RETURN /EXHAUST HP RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT VD VOLUME DAMPER 1 1 ZD ZONE DAMPER ND MOTORIZED DAMPER. FD FIRE DAMPER FSD FIRE /SMOKE DAMPER (120V POWER REQ.) CEILING RADIATION DAMPER SO SMOKE DETECTOR T THERMOSTAT S SENSOR R REFRIGERANT LINES G NATURAL GAS LINES S90 CEILING DIFFUSER (SUPPLY) 0.2" CEILING DIFFUSER (RETURN /EXHAUST) 1 EXHAUST FAN (CEILING MOUNTED) INLINE FAN GROAN PROPELLER FAN 90 SIDEWALL DIFFUSER CITY OETUnI ^iiLF 115 1 DUCT FITTING AUG 1 2 20 PERM -CENT. BROAN DATUM 90 UNIT TAG 115 DUCT RISER EXHAUST FAN SCHEDULE MARK MANF. MODEL CFM SP VOLTS PHASE HP NOTES EF ,1 GROAN S90 90 0.2" 115 1 0.5A EF 2 BROAN S90 90 0.2 115 1 0.5 A EF 3 BROAN S90 90 0.2" 115 1 0.5A EF 4 GROAN S90 90 0.2" 115 1 0.5 A EF5 BROAN S90 90 07 115 1 0.5A 7 -5/8" COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.1. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.3. FOR WAREHOUSES, SEMIHEATED SPACES, AND SIMPLE SYSTEMS (AS DEFINED IN WSEC SECTION 14215 HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE ,TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT. OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4.1. FOR ALL. OTHER SYSTEMS; HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1- 110.4.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.4.2.1; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED _PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416A.2.2,1 AND 1416.4.2.3; AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.1. EF - 1 -5 FILL I understand that the P an Check approvals are subject to errors and omissions ons roval of plans does not authorize the violation any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. By Date Permit No. SEPARATE PERMIT REQUIRED FOR: 0 MECHANICAL t ELECTRICAL PLUMING GAS PIPING CITY ^F TUK` ILA BUILDING DIVISION REVISIONS 3 ,SHALL BE MADE TO E WORK WITHOUT PRIOR F TUKWILA SUILDING DIVISION. :c (X1LL .'_'31.1ME A NEW PLAN SUEVINITAL PTA, fi^ • FC'3. GENERAL NOTES DUC WORK I.I ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2' TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4'1 EACH DIMENSION IF DUC I WORK IS ON THE EXTERIOR OF BUILDING. I1L II/SF NUMBER ON ALL DUCT DIMENSIONS W'I 11E WIDTH AND 1. SECOND NUMBER IS THE HEIGHT. I. 5 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS HIAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50. PER UMC 1997, SEC.601.4. I.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE I/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS-I8. ALL DUCT GAUGES PER TABLE 6-A S TABLE 6 -8 OF .1997 UMC. I.o ALL DUCT SUPPORTS PER TABLE 6-E OF 1997 UMC. I.7 AI TACII DIFFUSERS AIJD GRILLES TO T -DAR GRID PER 'CODES. I.b BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. DUCT INSULATION ?.I INSULATE OR LINE DUCTWORK PER W STATE ENERGY AND MECHANICAL CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR. AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING ANU FIRE PROOF LINIfJG PEN V.MC. GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERI BEFORE FRAMING OPENINGS. GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. GENERAL CONTRACTOR 10 PROVIDE ADEQUATE ENGINEERING AS REWIRED FOR MECHANICAL WORK. 3.. GLIILTAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL LOUIPPIENT. 1. Er1ERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERI, PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 5.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 5.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 6A OF UNIFORM. BUILDING. CODE .(1997 EDITION), WHERE REQUIRED BY SECTION 711 OF UBC (1997). ELECTRICAL L.I E <I IO INSTALL ALL LOW VOLTAGE CON 'I ROL WIRING. CONDUIT v./ILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS. DISCQ/NECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH .1 MECHANICAL PLAN AND WITH FIELD CONDITIONS ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM'EXHAUST FANS WITH LIGHT SWIT LRI Tu PROVIUL / NIGHT SE TBACK, PROGRAMMABLE TYPE T -STAY WITH. CAPABILITY OF 5`F DEADBAND ' c, TO VERIFY" FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. PLUMBING 6.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS'. PIPING FOR MECHANICAL EQUIPMENT PER CODE:: 5.2 PL. -WING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 3' ABOVE. HIGHEST POINT OF INTAKE: 5.5 CONDENSATE DRAINS AND DRAIN LINES BY ERI:, DRAIN TO ROOF, WITHIN T2' OF UNITS. ENERGY CODE COMPLIANCE 6.1 At A MINIMUM, EACH FLOOR IS TO BE CONSIDERED SEPERATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS 0.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EOUIPED WITH DAMPERS WHICH CLOSE AUTGI1ATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE. PER WSEC SEC. 1412.4.E 5 AIR ECONOMISERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100, CAPABILITY, CONTROL AND OPERATION OF THE ECONOMISER SHAL5 COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE I VV.. REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN SUPPLY AIR PER UMC 1997 SEC. 608. 5.2 0 (4 z • cN 0 O N ^ CC W WC i5 IDEAS < TeE r+16 SPEC ffIGT .se(165 6. ace .YfrfNTi vEPUE.SpTE6 Trf6e NAT o ar iir7 � ru ew ccra�.a„rm+ � vrsu� c mr r a c T v` r,c ne • naa Aver ccar e�mr o v acrrrruc¢ ar r �s�au.�usa Nat NO CD 0 (/). REVISIONS DATE. CIJ CLi Q co � Z Q O f Z U l a. 1.6� VJ Q LLI > 0 Q CD ITEM DRAWING DATE: 08 -09 -02 DWG. BY: GN CHK. BY: ML /NB JOB NO.: 025051 DWG. FILE: USHEALTHM1 0 HEALTH VVORKS 11 PROGRESS PRINTS - NOT FOR CONSTRUCTION COVER SHEET CONSTRUCTION DRAWINGS AS BUILT DRAWINGS 2 -1'2 TON ^,';' TING RECEP HON , 414, FLOOR PLAN SCALE : 1/8" = 1' -0" KEYNOTES: EXISTING RESTROOM EXISTING FANS 1 ) 1:1U 1,2,3,4. ARE EXISTING, DUCT TENANT IMPROVEMENT ONLY 3 DISTRIBUTION DUCTWORK FROM RTU 3 8 4 IS EXISTING' 4) DRYER VENT TO ABOVE' GO o ILIKqa ,GOAD AUG 15 2092 RECENED CITY OFTUKWiLA AUG 1 2 ZOOZ PERMIT CENTER V z 0 O NOT R:4IMQ x1 ...RS INNI R/ELL THE pR1Wl. INS SPELyWTONS, ID, 13.144.5 R ININ TH TE6 M1(1E1'r 9 N REwtU THE C PANT OG rr Sm.- E NEP RNT LL t6 NR T , MIL- YELL INS r CIDER. IDER. AUK., - E2 [� ID ffiiRWfEU TQ 61eQ1S- 418. Vr1 Bt RI1f. 1CZYSED vRFOIT ME Re®R VR m GA.If � VG VI41Y_ CORRCT vIM TiK • ar C11 fA CesiS EV[G RRS LitC. C1Y�STI(ISTE ¢uIIVE ETSCc 6 11 KSFPfw¢ 5 Tuer R£ ° NO W W W Q Q Q Q Q Q 0 ® ❑ ❑ ❑ REVISIONS DATE DRAWING DATE: DWG: BY: CHK. BY: JOB NO.: DWG. FILE: M2 co f- • Z a 0 LU CC z LU 3 a aQ ¢ Y = N h ITEM 08 -09 -02 GN ML /NB D25051 USHEALTHM2 OF